cc/td/doc/product/wanbu/mgx8260/rel1_2
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

System Specifications

System Specifications

Physical Specifications

Table B-1 lists the physical dimensions and requirements for the MGX 8260 media gateway.


Table B-1: MGX 8260 Physical Specifications
Description Specifications

Number of Card Slots

16 per chassis

Dimensions

(H x W x D)
Chassis: 24.5 in. x 17.5 in. x 18 in. (62.23 cm x 44.45 cm x 45.72 cm) (14 RU)
Plenum: 3.5 in. x 17.25 in. x 16.63 in. (8.89 cm x
43.82 cm x 42.24 cm) (2 RU)
AC/DC power supply (option): 5.25 in. x 17 in. x 13 in. (13.34 cm x 43.18 cm x 33.02 cm)
Shipping container: 38 in. x 27.5 in. x 27.5 in.
(96.5 cm x 70 cm x 70 cm) (3 RU)

Mounting

19 in. and 23 in. rack-mount

Clearance Requirements

36 in. (91 cm) front and rear

Weight

Varies according to card configuration.
Maximum weight (all card slots populated): 170 lbs (77.11 kg)

Power Specifications

Table B-2 lists the power specifications for the MGX 8260 media gateway.


Table B-2: MGX 8260 Power Specifications
Description Specifications

Input

DC (standard option): -40 VDC to -56 VDC

Consumption

1800 watts (fully loaded)

Environmental Specifications

Table B-3 lists the environmental specifications for the MGX 8260 media gateway.


Table B-3: MGX 8260 Environmental Specifications
Description Specifications

Storage

-40°F to 158°F (-40°C to 70°C)

Operating

Normal: 41°F to 104°F (5°C to 40°C)
Short-term: 23°F to 122°F (-5°C to 50°C)

Humidity

Normal: 5% to 85% relative humidity, noncondensing
Short-term: 5% to 90%, not to exceed 0.024 kg of water/kg of dry air

Cooling

Forced air and redundant managed fans

Heat Load

6200 BTUs (fully loaded)

Safety and Emissions

FCC Part 15 Class A, 68
EN 55022, 60950 (TUV/VDE), 50082-1, EN 300 386-2
UL 1950
CAS 22.2 No. 950
NEBS Level 3 Bellcore GR-1089-CORE, Bellcore GR-63-CORE

Monitoring and Alarms

Temperature of chassis and each card
Voltage on backplane and each card
Fan speed

System Control Card Specifications

Table B-4 lists System Control Card (SCC) design specifications for the MGX 8260 media gateway.


Table B-4: MGX 8260 SCC Design Specifications
Description Specifications

CPU

RISC 5000

Memory

128 MB DRAM or
256 MB DRAM
2 MB Flash

Flash Disk Drive

220 MB (non-volatile RAM drive)

Switching Fabric and Interfaces

Table B-5 lists the switching fabric and interface specifications for the MGX 8260 media gateway.


Table B-5: MGX 8260 Switching Fabric and Interface Specifications
Description Specifications

Switching fabric

5 Gbps

Distribution Matrix Card (DMC)

Supports up to six channelized T3 TDM interfaces per card (acting as an M13 MUX for the NSC cards)
Up to 2 cards per system (slots 7 and 8)

Narrowband Services Card (NSC)

16 T1/E1 TDM interfaces per card with up to 16 D-channels per card for PRI (NFAS) configuration.
RJ-21X and RJ-48 modules available for T1/E1 network connections.

Narrowband Services Card (NSC) DSP module

Static and dynamic jitter buffer (10 ms to 200 ms)
Configurable echo cancellation (G.165/G.168)
DTMF tone generation and detection
G.711, G.726, G.729a voice encoding
Fax/modem detection and by-pass
Voice Activity Detection (VAD) with Silence Suppression and Comfort Noise Generation (CNG)

System Control Card (SCC)

Four 100BASE-T module
Four
ATM OC-3 module
Two
10BASE-T management ports
Two
RS232 (EIA-574) console ports
BITS clock connection
Alarm connection

Broadband Service Card (BSC)

6 DS3 interfaces per card (SMB connectors)
3/1/0 functionality and TDM switching between ports
Up to 6 cards per system (slots 11-16)

Clocking

BITS
External (incoming digital trunk)
Internal
Stratum 4

Supported Protocols

Table B-6 lists the protocols supported by the MGX 8260 media gateway.


Table B-6: MGX 8260 Supported Protocols
Description Specifications

WAN

T1, E1
T3
ISDN PRI (separate licensing required per BSC)
Q.931 SS7 messaging via D-channels

LAN

10BASE-T Ethernet
Fast Ethernet (100BASE-TX)
ATM over single-mode or multi-mode (optional) fiber OC-3 interface (to MGX 8850 only)

Codecs

G.711
G.726
G.729a

Call Processing

IPDC, MGCP

Management

SNMP (v1)

Redundancy

Table B-7 lists the redundancy specifications for the MGX 8260 Media Gateway.


Table B-7: MGX 8260 Redundancy Specifications
Description Specifications

SCC

1:1

BSC

1:1

DMC

1:1

NSC

1:N

Power

1:1


hometocprevnextglossaryfeedbacksearchhelp
Posted: Sat Sep 28 22:20:39 PDT 2002
All contents are Copyright © 1992--2002 Cisco Systems, Inc. All rights reserved.