cc/td/doc/product/wanbu/mgx8260/rel1
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Release Notes for MGX 8260 Software Release 1.0

Release Notes for MGX 8260 Software Release 1.0

Contents

These release notes describe the following topics:

System Requirements

Hardware Information

Board Name Part Number Version

SCC5FC-4FE

800-06392-01

B0

SCCBC-4FE

800-06325-01

B0

NMCFC-8DSP

800-06327-01

C0

T1E1Nred BC

800-06323-01

B0

DMCFC-6T3

800-06326-01

C0

T3E3 BC-6DSX

800-06324-01

C0

MGX8260

800-06541-01

A0

Software Information

Important Notes

File Information

For R01.00.00 Images, in tar_files directory, it contains the images of scc.tar and nmc.tar files for all board types (i.e, scc, nmc) and all html files.

To untar files

tar xvf <filename>
Note   <filename> : scc, nmc, html

The following is the list of files and sizes contained in each of the tared modules listed above:

SCC Files

TAR image is in the tar_files directory. Four (4) Binary files are in the binary_files/scc folder

.File Name Size Checksum

SCC_B.r01.00.00.hx1

865955

D5D4

SCC_B.r01.00.00.hx2

865955

515E

NMC Files

TAR image is in the tar_files directory. Four (4) Binary files are in the binary_files/nmc folder

File Name Size Checksum

NMC.B.r01.00.00.hx1

863953

27B4

NMC.B.r01.00.00.hx2

863953

9EE4

HTML Files

There are 446 files. TAR image is in the tar_files directory. HTML files are in the binary_files/html folder.

Caveats

Open Caveats - Release R01.00.00

  
Bug ID Severity Title Description Impact Workaround

CSCtm01609

2

Signal Loss of BITS Clock is not detected

On release 1.0, it was discovered that the CSM hardware cannot detect the LOS when BITS clock is removed. Hence, there is no clock switching when we loose BITS clock due to LOS.

If there is no BITS clock due to LOS on the T1 span, there will be clock slippage.

Use NMC T1 line as external stratum clock source.

CSCtm01572

2

Hard drive corrupted during dbbackup and restore process.

The problem is when the IDE hard drive contains bad sectors. This issue is not detected until the software tries to use the sector for storage. This causes the drive to fails.

Hard drive failure.

None

CSCtm01553

2

STDBY SCC intermittently gets into FAIL state due to IDE malfunction

Defect or malfunctioning IDE cause the SCC to fail. Switchover occurs to prevent disruption to service. If problem occurs in standby SCC, operator can replace without disruption to service.

Loss of redundancy coverage until the drive is replaced.

CSCtm01521

2

Can't recover access to failed DSP

If there is a DSP failure on the MSM-DSPV module, the current FPGA does not time-out on read/write access to the device. This causes the host processor to hang. Hence, the hardware watchdog is triggered.

This will cause the NMC to be reset by hardware watchdog.

CSCtm01599

3

24hr Call Completion test yields less than 100% due to the MCS call agent

100% call completion can't be achieved when using MCS (TransMedia's call agent) for call control. MCS is no longer supported.

Not applicable

CSCtm01408

3

Add extra field in lsClkSrc for software/customer clock src setting

Needs to display clock synch source along with other info when querying clock source data

None

CSCtm01396

3

lslns does not display T3 lines

Needs to display data for T3 lines when using lslns CLI command

none

CSCtm01382

3

Capital letters are not accept as a key when attempting to download bootcode

Capital letters are allowed for filename in bootcode download, but only small letters are used in download utility.

None

Don't use capital letters

CSCtm01001

3

SCC 10 line integrated alarm does not reflect line status

The integrated alarm on the SCC in slot 10 shows incorrect alarm for the SCC due to logical slot mapping

Alarms on the SCC itself may be incorrectly reported.

None

CSCdp47831

3

DMC clock source not acknowledged after SCC switchover

When DMC is the primary source for the clock and it is switched over, the clock source becomes applicable on the stand by DMC after it is re-applied

After the SCC switch over, the DMC clock source fails; this result in a clock switch to the secondary clock source.

Provide a good secondary clock source other than DMC. After SCC switch over, re-program the DMC clock source as primary clock source.

CSCdp47723

3

ESF/AMI ones density scheme needs to be determined.

When user selects AMI as line coding, there is no one-density insertion to prevent one-density violation.

This will cause the CPE side to loose frame synchronization due one density violation.

Use B8ZS line coding.

CSCtm01607

4

Unable to clear errors on onbertds1 tests.

BERT test statistics can't be cleared

none

Need to know BERT status before starting test run

CSCtm01603

4

Invalid performance and statistics data are displayed for newly added DS1

When a new DS1 is added, some invalid performance and statistics are shown when printed

None

Clear data manually after adding new line

CSCtm01584

4

Cannot list MSM cards with lsmsms.

When printing info for card configured with 2 MSM, card configuration are not shown

None

CSCtm01569

4

Can't adjust line length on the DS1 loop

LBO needs to be adjustable for different line length. Today we support the short line length.

None

None

CSCtm01564

4

Boot code hang in VxWorks banner

The VxWorks banner is not displayed in the NMC after rebooting the NMC 100+ times

None

issues `resetcd'command from the SCC

CSCtm01561

4

Second DSPV card does not show when listing a NMC card with two

When printing info for card configured with 2 MSM, card configuration are not shown

None

CSCtm01559

4

Changing a vport using "#" or " " as a <voicePortNumRepetition> fails

The number of repetition for voice port was not defaulted to 1. Hence, there is no default. If user tries to use it as default (#), the operation will fail.

None

CSCtm01546

4

Degraded Minutes performance parameter not supported.

Bursty Errored Seconds are not supported, but CLI and WebEm fields reserve/print fields for them

None

CSCtm01525

4

onbertds1 CLI cmd option specifies # of DS0's to test, s/b bit m

onbertds1 testing data is displayed in Bit map format. The output may appear to be for DS0

None

CSCtm01495

4

NMC Firmware version not printed

NMC bootcode version is not printed if the bootcode is loaded via burning in the chip. This work fine if the bootcode is downloaded via the update command

None

CSCtm01395

4

Clock Synch HW can't detect signal loss

This is the same issue as CSMtm01609

After entering "clrcdcnf" followed with a space " " the system printed an error message followed by a Login: prompt. This only occurs if the clrcdcnf command is followed by a space and no card number.

Entering the lscd # command prints many fields. The Software Revision Field and Firmware Revision Field display is reversed.

CSCtm01391

4

clrcdcnf command

An error message is printed if a space is typed following the clrcfcnf command (i.e. "clrcdcnf ")

None

CSCtm01336

4

Software revision field on lscd command displays wrong info.

Entering the lscd # command reveals many fields. It appears that the printing of the Software Revision Field and Firmware Revision fields have their information reversed.

None

CSCtm01310

4

Announcement file registry is lost after DB cleared.

The announcement files are not loaded on to the NMCs after the DB is cleared.

Re-downloading all the .wav files again to be registered.

CSCtm01163

4

ALM parity error while trying to add voice connections.

ALM hardware generates parity error while adding voice connections.

None

None

CSCtm01049

4

Illegal IP address allowed with addcms command.

Illegal IP address allowed with addcms

None

Verify entry of IP address

CSCtm00612

4

Netscape browser cannot bring up Chassis View 1st time after the PC

When Netscape browser may not come up with the chassis view when used for WebEM for the very first time.

None

Kill Netscape and try again and it should work


Access Registrar, AccessPath, Any to Any, AtmDirector, Browse with Me, CCDA, CCDE, CCDP, CCIE, CCNA, CCNP, CCSI, CD-PAC, the Cisco logo, Cisco Certified Internetwork Expert logo, CiscoLink, the Cisco Management Connection logo, the Cisco NetWorks logo, the Cisco Powered Network logo, Cisco Systems Capital, the Cisco Systems Capital logo, Cisco Systems Networking Academy, the Cisco Systems Networking Academy logo, the Cisco Technologies logo, ConnectWay, Fast Step, FireRunner, Follow Me Browsing, FormShare, GigaStack, IGX, Intelligence in the Optical Core, Internet Quotient, IP/VC, Kernel Proxy, MGX, MultiPath Data, MultiPath Voice, Natural Network Viewer, NetSonar, Network Registrar, the Networkers logo, Packet, PIX, Point and Click Internetworking, Policy Builder, Precept, ScriptShare, Secure Script, ServiceWay, Shop with Me, SlideCast, SMARTnet, SVX, The Cell, TrafficDirector, TransPath, ViewRunner, Virtual Loop Carrier System, Virtual Service Node, Virtual Voice Line, VisionWay, VlanDirector, Voice LAN, WaRP, Wavelength Router, Wavelength Router Protocol, WebViewer, Workgroup Director, and Workgroup Stack are trademarks; Changing the Way We Work, Live, Play, and Learn, Empowering the Internet Generation, The Internet Economy, and The New Internet Economy are service marks; and ASIST, BPX, Catalyst, Cisco, Cisco IOS, the Cisco IOS logo, Cisco Systems, the Cisco Systems logo, the Cisco Systems Cisco Press logo, Enterprise/Solver, EtherChannel, EtherSwitch, FastHub, FastLink, FastPAD, FastSwitch, GeoTel, IOS, IP/TV, IPX, LightStream, LightSwitch, MICA, NetRanger, Post-Routing, Pre-Routing, Registrar, StrataView Plus, Stratm, TeleRouter, and VCO are registered trademarks of Cisco Systems, Inc. or its affiliates in the U.S. and certain other countries. All other trademarks mentioned in this document are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any of its resellers. (9912R)

Copyright © 1999, Cisco Systems, Inc.
All rights reserved.


hometocprevnextglossaryfeedbacksearchhelp
Posted: Sat Sep 2 19:00:47 PDT 2000
Copyright 1989-2000©Cisco Systems Inc.