Specifications

BNM-T3 Specification

Intershelf Link

Card General

BNM-E3 Specification

Intershelf Link

Card General

BNM-155 Specifications

Intershelf Link Specifications

ASC Specification

SRM-T1/E1 Specification

FRSM-4T1 Specification

Service Interface

System Interface

Virtual Circuits

Card General

FRSM-4E1 Specification

Service Interface

System Interface

Virtual Circuits

FRSM-8T1 Specification

Service Interface

System Interface

Virtual Circuits

Card General

FRSM-8E1 Specification

Service Interface

System Interface

Virtual Circuits

FRSM-HS2 Specification

Errors and Alarm Handling

External Interface Specification

AUSM Specification (4 Port)

Service Interface (T1)

Service Interface (E1)

ATM Interface

Virtual Circuits

Card General

CESM-4T1/E1 Specification

Service Interface (T1/E1)

Virtual Circuits

MATM Specification

Physical Layer Interface T1:

Physical Layer Interface E1

Physical Layer Interface T3

Physical Layer Interface E3

AIM Groups and Links

Card General

Specifications


BNM-T3 Specification

Intershelf Link

T3 line interface connector:

BNC connector per ANSI T1.404

T3 cable recommended:

Coax, 75 ohm, 728A or equivalent

T3 line signal:

DSX-3 Specification per ANSI T1.102 and ATT PUB 54014

T3 line rate:

44.736 Mbps ± 895 bps

T3 framing:

Asynch. C-bit Parity per ANSI T1.107a

Input jitter tolerance:

Per ATT TR 54014, Category II Equipment

Output jitter generation:

Per ATT TR 54014, Table B1, "Equipment with DS3 Oscillator" Category

PMD layer alarms:

LOS, OOF, AIS, RAI

PMD layer performance statistics:

LCV, LES, % EFS, LSES, SEFS, PCV, PES, PSES, SEFS, UAS

Trans. convergence protocol:

PLCP per TR-TSV-000773

TC layer alarms:

OOF, RAI

TC layer performance statistics:

BIP8-CV, BIP8-ES, BIP8-SES, SEFS, UAS

ATM layer protocol:

Header check sum is XORed with the COSET function
(0 x 55) per CCITT I.361

ATM layer counters:

Number of cells received good
Number of cells received and discarded due to bad HEC
Number of cells transmitted good
Number of cells received from cell bus
Number of cells transmitted to cell bus

Diagnostics:

Header of first cell received with invalid egress translation entries
Number of cells dropped due to invalid egress translation entries


Card General

Synchronization:

Derives 8-kHz shelf synchronization clock from a variety of sources:

Internal 8-kHz clock (10 ppm)

BNM-T3 PLCP

External T1/E1 clock port with a clock rate of
1.544 Mbps ± 50 bps (T1) or 2.048 Mbps ± 100 bps (E1)

External Office clock interface:

DB-15 connector using LM-T3/E3-D (T1/E1 clock)
BNC connector using LM-T3/E3-B (E1 clock)
Alarm interface: CO compatible alarm indicator and control
DB-15 connector

Indicators:

Per card: active (green), failed (red), standby (yellow)
T3 Interface: active and okay (green)
Active and local alarm (red)
Active and remote alarm (yellow)

Minor DS-3 statistical alarm

Maintenance/Serviceability Features:

Internal isolation loopbacks
External remote loopback
Hot-pluggable

Reliability:

> 65000 hours MTBF

Card Size:

BNM-T3: 7.25 in. x 16.25 in.
LM-T3E3-D: 7.25 in. x 4.5 in.
LM-T3E3-B: 7.25 in. x 4.5 in.

Power:

-48V DC, 25W


BNM-E3 Specification

Intershelf Link

E3 Line Interface Connector:

BNC connector per ANSI T1.404

E3 Cable Recommended:

Coax, 75 ohm, 728A or equivalent

E3 Line Signal:

Per G.703

E3 Line Rate:

34.368 Mbps ± 20 PPM

E3 Framing:

G.832 and G.804

Input Jitter Tolerance:

Per G.703

Output Jitter Generation:

Per G.703

PMD Layer Alarms:

LOS, OOF, AIS, RAI

PMD Layer Performance Statistics:

LCV, LES, %EFS, LSES, SEFS, PCV, PES, PSES, SEFS, UAS

Trans. Convergence Protocol:

PLCP per TR-TSV-000773

TC Layer Alarms:

OOF, RAI

TC Layer Performance Statistics:

BIP8-CV, BIP8-ES, BIP8-SES, SEFS, UAS

ATM Layer Protocol:

Header check sum is XORed with the COSET function (0x55) per CCITT I.361

ATM Layer Counters:

Number of cells received good

Number of cells received and discarded due to bad HEC

Number of cells transmitted good

Number of cells received from cell bus

Number of cells transmitted to cell bus

Diagnostics:

Header of first cell received with invalid egress translation entries

Number of cells dropped due to invalid egress translation entries

Number of unacknowledged cells transmitted to cell bus


Card General

Synchronization:

Derives 8-kHz shelf synchronization clock from a variety of sources:

E3 physical interface

External T1/E1 clock port with a clock rate of 1.544 Mbps ± 50 bps (T1) or 2.048 Mbps ± 100 bps (E1)

External Office clock interface:

DB15 connector using LM-T3/E3-D (T1/E1 clock)
BNC connector using LM-T3/E3-B (E1 clock)

Alarm interface:

CO compatible alarm indicator and controls DB-15 connector

Indicators:

 

Per Card:

Active (green), failed (red), standby (yellow)

E3 Interface:

Active and okay (green)
Active and local alarm (red)
Active and remote alarm (yellow)

Minor DS-3 statistical alarm

Shelf Voltage:

Voltage okay (green) B voltage okay (green)

Alarms:

Major (red), minor (yellow) ACO (yellow), history (green)

Maintenance/Serviceability Features:

Internal isolation loopbacks

External remote loopback

Hot-pluggable

Card Size:

BNM-T3: 7.25 in. x 16.25 in.

LM-T3E3-D: 7.25 in. x 4.5 in.

LM-T3E3-B: 7.25 in. x 4.5 in.

Power:

-48V DC, 25W


BNM-155 Specifications

Intershelf Link Specifications

Common Specifications

Framing:

SONET STS-3c per ANSI T1.105

PMD Layer Alarms:

Loss of signal (LOS)
Severely errored framing (SEF)
Loss of frame (LOF)
Line alarm indication signal (AIS-L)
STS path alarm indication signal (AIS-P)
Line remote defect indication (RDI-L)
Loss of pointer (LOP)
STS path remote defect indication (RDI-P)

Transmission Convergence Protocol:

Per GR-253-CORE and ANSI T1.105

TC Layer Alarm:

Loss of cell delineation (LCD)

ATM Layer Protocol:

Header check sum is XORed with the COSET function (0 x 55) per CCITT I.361

ATM Layer Counters:

Number of cells received good
Number of cells received and discarded due to bad HEC
Number of cells transmitted good

Diagnostics:

Number of cells received from cell bus
Number of cells transmitted to cell bus
Number of unacknowledged cells transmitted to cell bus
Header of first cell received with invalid egress translation errors
Number of cells dropped due to invalid ingress translation errors
Number of cells dropped due to invalid egress translation entries


SMF Specific Specifications

SMF Line Interface Connector:

SC connectors

Fiber Recommendation:

Single-mode

Maximum Fiber Length:

20 km

SMF Line Signal:

Optical, SONET OC-3c per ANSI T1.105 and GR-253-CORE

SMF Line Rate:

155.52 Mbps

Input Jitter Tolerance:

Per Gr-253-CORE

Output Jitter Generation:

Per Gr-253-CORE


General Card Specifications

Synchronization:

Derives 8 kHz shelf synchronization clock from a variety of sources:

Internal 8 kHz (±10 ppm)

BNM-155 PLCP

External T1/E1 clock port with a clock rate of 1.544 MHz ±50 ppm (T1) or 2.048 MHz ± 100 bps (E1)

External Clock Interface:

DB-15 connector or BNC connector (both are available)

Alarm Interface:

CO compatible alarm indicator and controls via DB-15 connector

Indicators:

Ten LEDs

Per Card

Active (green)
Failed (red)
Standby (amber)

OC-3 Interface

Single multihue LED
Active and okay (green)
Active and local alarm (red)
Active and remote alarm (amber)

Shelf Voltage

A voltage okay (green)
B voltage okay (green)

Alarms

Major (red)
Minor (amber)
ACO (amber)
History (green)

Maintenance Serviceablity Features:

Internal isolation loopbacks
External remote loopbacks
Hot-pluggable

Reliability

> 65000 hours MTBF

Card Size

BNM-155: 7.25 in. x 16.25 in.
SMF-155-LM: 7.25 in. x 4.5 in.
UTP-155-LM: 7.25 in. x 4.5 in.

Power

-48V DC, 25W


ASC Specification

802.3 LAN Interface Connector:

AUI interface using DB-15 connector control port: DB-25 RS232 connector; Asynch interface, 99200 baud, 1 start,
1 stop, no parity

Troubleshooting Interface:

Maintenance port: DB-25 RS232 connector; Asynch interface, 9600 baud, 1 start, 1 stop, no parity

Indicators:

Per card: active (green), failed (red), standby (yellow)

LAN activity/flashing green

Maintenance/ Serviceability Features:

RS232 maintenance/debug port

Internal isolation loopbacks

Hot-pluggable

Reliability:

> 65000 hours MTBF

Card Size:

ASC: 7.25 in. x 16.25 in.

LM_ASC: 7.0 in. x 4.5 in.

Power:

-48V DC, 25W


SRM-T1/E1 Specification

T1/E1 Line Interface Connector:

BNC-3T#
Standby SM requires a special line module:
R-DB15-4T1 if active cards use DB15-4T1
R-DB15-4E1 if active cards use DB15-4E1
R-BNC-4E1 if active cards use BNC
R-RJ48-8T1 if active cards use RJ-48-8T1
R-RJ48-8E1 if active cards use RJ-48-8E1
R-SNB-4E1 if active cards use SMB-8E1

Line Rate:

T1: 1.544 Mbps ±75 bps (50 ppm)
E1: 2.048 Mbps ± 100 bps (50 ppm)

Transmit Clocking:

Normal or looped timed

Input Jitter Tolerance:

Per AT&T Accunet T1.5 Service 1990 - T1
Per G.703 - E1

Physical Layer Alarms:

Indicated in service modules

Physical Layer Performance Statistics:

N/A

Indicators:

 

Per Card:

Active (green), failed (red), standby (yellow)

BERT:

Active (green), errors (yellow)

1 to N Redundancy:

Active (green)

Indicator for each T3:

Active (green)

Maintenance/Serviceability Features:

DS1 Loopback toward service modules
Hot pluggable

Reliability:

>85000 hous MTBF

Card Size:

Front card: 7.25 in. x 16.25 in.
Back card: 7 in. x 4.5 in.

Power:

48V DC, 50 W

Loopback codes:

Fractional T1 in-band loopback -
ANSI T1/E1-2/92-003 R3

DS0 loopback -
TA-TSY-000055
TA-TSY-000057
TA-TSY-0000476

Monitoring trouble codes:

TA-TSY-000077
TA-TSY-0000280
ATT TR-62310


FRSM-4T1 Specification

Service Interface

Line Interface connector:

DB-15—when used with LM-DB15-4T1 line module

Line Rate:

1.544 Mbps ± 50 bps

Line Framing:

ESF per ATT TR 54016

Synchronization:

Transmitter can be either loop-timed to receiver or synchronized to shelf (called normal mode)

Input Jitter Tolerance:

Per ATT TR 62411

Output Jitter Generation:

Per ATT TR 62411 using normal mode synchronization

Physical Layer Alarms:

LOS, OOF, AIS, RAI

Number of Frame Relay Ports:

1-Single Frame Relay stream occupying n consecutive time slots

Frame Relay Interface Rates:

Either 56 kbps or n* 64 kbps; n as defined previously

Frame Relay Interface:

Per ANSI T1.618, 2-octet header

Frame Relay Performance Counters (per port; n x DS0):

Receive frames discarded due to Aborts
Receive frames discarded due to illegal header (EA bits)(S)
Receive frames discarded due to CRC errors (S)
Receive frames discarded due to alignment errors (S)
Receive frames discarded due to unknown DLCI (S)
Receive frames discarded due to illegal frame length (S)
Receive frames discarded due to DE threshold exceeded
Receive frames with DE already set
Receive frames with FECN already set
Receive frames with BECN already set
Receive frames tagged FECN
Receive frames (S)
Receive bytes (S)
Transmit frames discarded due to underrun
Transmit frames discarded due to Abort
Transmit frames discarded due to egress Q-depth exceeded (S)
Transmit bytes discarded due to egress Q-depth exceeded (S)
Transmit frames discarded due to egress DE threshold
exceeded Transmit frames (S)

 

Transmit bytes (S)
Transmit Frames with FECN set (S)
Transmit Frames with BECN set (S)

 

LMI receive status inquiry request count (S)
LMI transmit status inquiry request count
LMI invalid receive status count (S)
LMI signaling protocol (keep alive time-out count) (S)
LMI sequence number error count (S)
LMI receive status transmit count (in response to request)
LMI transmit status transmit count (in response to request)
Transmit frames during LMI alarm (S)
Transmit bytes during LMI alarm (S)
LMI update status transmit count (in response to configuration changes)

Diagnostics (per port):

Last unknown DLCI received


System Interface

ATM Layer:

Per CCITT I.361 and ATM UNI v3.1

AAL Layer:

AAL5 per Draft CCITT I.363

FR-Cell Interworking:

Per Draft CCITT I.555 and I.36x.1, as summarized in
Frame Relay Forum, FR/ATM PVC Interworking Implementation Agreement FRF.5


Virtual Circuits

Channels (Endpoints):

256 per card—can be allocated across any of the Frame Relay interfaces

Counters:

 

Service Counters:

Number of frames received (S)
Number of bytes received (S)
Number of frames received with DE already set (S)
Number of bytes received with DE already set (S)
Number of frames received with unknown DLCI
Number of frames received but discarded (S)
Number of received bytes discarded (S)
Number of received bytes discarded due to exceeded Q-depth (S)
Number of frames received and discarded due to

intershelf alarm

exceeded DE threshold

exceeded Q depth

Number of frames received with FECN set
Number of frames received with BECN set
Number of frames received tagged FECN
Number of frames received tagged BECN

 

Number of frames transmitted (S)
Number of bytes transmitted (S)

 

Number of frames transmitted with DE set
Number of frames discarded due to reassembly error (S)
Number of frames transmitted during LMI logical port alarm
Number of frames transmitted with FECN set
Number of frames transmitted with BECN set
Number of transmit frames discarded
Number of transmit bytes discarded
Number of transmit frames discarded due to: CRC error (S)

egress Q depth exceeded

egress DE threshold exceeded source abort

physical link failure (T1)

ATM cells—Number of cells transmitted to BNM
Number of cells transmitted with CLP bit set
Number of OAM AIS cells transmitted
Number of OAM FERF cells transmitted
Number of BCM cells transmitted
Number of OAM end-end loopback cells transmitted
Number of OAM segment loopback cells transmitted
Number of cells received from BNM
Number of cells received with CLP bit set
Number of OAM AIS cells received
Number of OAM FERF cells received
Number of BCM cells received
Number of OAM end-end loopback cells received
Number of OAM segment loopback cells received
Number of OAM cells discarded due to CRC-10 error (S)

Statistics:

All previous counters followed by an (S) can be configured as statistics

Diagnostics:

Last unknown LCN received cells with unknown LCN count


Card General

Indicators:

 

Per Card:

Active (green), standby (yellow), fail (red)

Lines (one per):

Active and okay (green)
Active and local alarm (red)
Active and remote alarm (yellow)

Maintenance/Serviceability Features:

Internal problem isolation loopbacks hot-pluggable

Reliability:

> 65000 hours MTBF

Card Size:

FRSM-4T1: 7.25 in. x 16.25in.
LM-DB15-4T1: 7.0 in. x 4.5 in.
Power: -48V DC, 30W (4 T1s)


FRSM-4E1 Specification

Service Interface

Line Interface connector:

DB-15 when used with LM-DB15-4E1 line module

BNC when used with LM-BNC-4E1 line module

Line Rate:

2.048 Mbps ± 100 bps

Synchronization:

Transmitter can be either loop-timed to receiver or synchronized to shelf (called normal mode)

Input Jitter Tolerance:

Per G.703

Output Jitter Generation:

Per G.703

Physical Layer Alarms:

LOS, OOF, AIS, RAI

Number of Frame Interfaces:

I to 31 occupying n where 1 < n < 31. Sum of all < 31 for CCS. 1-30 for CAS

Frame Relay Interface Rates:

Either 56 kbps or n* 64 kbps; n as defined previously

Frame Relay Interface:

Per ANSI T1.618, 2-octet header

Frame Relay Performance Counters (per port; n x DS0):

Receive frames discarded due to aborts
Receive frames discarded due to illegal header (EA bit)(S)
Receive frames discarded due to CRC errors (S)
Receive frames discarded due to alignment errors (S)
Receive frames discarded due to unknown DLCI (S)
Receive frames discarded due to illegal frame length (S)
Receive frames discarded due to DE threshold exceeded
Receive frames with DE already set
Receive frames with FECN already set
Receive frames with BECN already set
Receive frames tagged FECN
Receive frames (S)
Receive bytes (S)

 

Transmit frames discarded due to underrun
Transmit frames discarded due to Abort
Transmit frames discarded due to egress Q-depth exceeded (S)
Transmit bytes discarded due to egress Q-depth exceeded (S)
Transmit frames discarded due to egress DE threshold exceeded Transmit frames (S)
Transmit bytes(S)
Transmit Frames with FECN set (S)
Transmit Frames with BECN set (S)
LMI receive status inquiry request count (S)
LMI transmit status inquiry request count
LMI invalid receive status count (S)
LMI signaling protocol (keep alive time-out count) (S)
LMI sequence number error count (S)
LMI receive status transmit count (in response to request)
LMI transmit status transmit count (in response to request)
Transmit frames during LMI alarm (S)
Transmit bytes during LMI alarm (S)
LMI update status transmit count (in response to configuration changes)

Diagnostics (per port):

Last unknown DLCI received


System Interface

ATM Layer:

Per CCITT I.361 and ATM UNI v3.1

AAL Layer:

AAL5 per Draft CCITT I.363

FR-Cell Interworking:

Per Draft CCITT I.555 and I.36x.1, as summarized in
Frame Relay Forum, FR/ATM PVC Interworking Implementation Agreement FERF.5


Virtual Circuits

Channels (Endpoints):

256 per card—can be allocated across any of the Frame Relay interfaces

Counters:

Service counters: Number of frames received (S)
Number of bytes received (S)
Number of frames received with DE already set (S)
Number of bytes received with DE already set (S)
Number of frames received with unknown DLCI
Number of frames received but discarded (S)
Number of received bytes discarded (S)
Number of received bytes discarded due to exceeded Q-Depth (S)
Number of frames received and discarded due to

intershelf alarm

exceeded DE threshold (S)

exceeded Q depth (S)

Number of frames received with FECN set
Number of frames received with BECN set

 

Number of frames received tagged FECN
Number of frames received tagged BECN
Number of frames transmitted (S)
Number of bytes transmitted (S)
Number of frames transmitted with DE set (S)
Number of frames discarded due to reassembly errors (S)
Number of frames transmitted during LMI logical port alarm (S)
Number of frames transmitted with FECN set (S)
Number of frames transmitted with BECN set (S)
Number of transmit frames discarded (S)
Number of transmit bytes discarded
Number of transmit frames discarded due to: CRC error (S)

egress Q depth exceeded (S)

egress DE threshold exceeded source abort physical link failure (T1)

 

ATM cells: Number of cells transmitted to BNM
Number of cells transmitted with CLP bit set
Number of OAM AIS cells transmitted (S)
Number of OAM FERF cells transmitted (S)
Number of BCM cells transmitted
Number of OAM end-end loopback cells transmitted (S)
Number of OAM segment loopback cells transmitted
Number of cells received from BNM
Number of cells received with CLP bit set
Number of OAM AIS cells received (S)
Number of OAM FERF cells received (S)
Number of BCM cells received
Number of OAM end-end loopback cells received (S)
Number of OAM segment loopback cells received
Number of OAM cells discarded due to CRC-10 error (S)

Statistics:

All previous counters followed by an (S) can be configured as statistics.

Diagnostics:

8 Last unknown LCN received
Cells with unknown LCN count
Card general

Indicators:

Per card: Active (green), standby (yellow), fail (red)
Lines (one per): Active and okay (green)
Active and local alarm (red),
Active and remote alarm (yellow)

Maintenance/Serviceability Features:

Internal problem isolation loopbacks
Hot-pluggable

Card Size:

FRSM-4E1: 7.25 in. x 16.25 in.
LM-DB15-4E1: 7.0 in. x 4.5 in.
LM-BNC-4E1: 7.0 in x 4.5 in.

Power:

-48V DC, 30W (4 E1s)

Ingress:

8000 cell buffer shared between virtual channels/paths
Standard usage parameter control (UPC)
Selective cell discard
Virtual circuit queuing
EFCI setting per VC

Egress:

8000 cell storage capacity shared between four ports
Up to 12-user-selectable egress queues per port
Selective cell discard
EFCI setting per queue


FRSM-8T1 Specification

Service Interface

Line Interface connector:

RJ-48 when used with LM-RJ-48-8T1 line module

Line Rate:

1.544 Mbps ± 50 bps

Line Framing:

ESF per ATT TR 54016

Synchronization:

Transmitter can be either loop-timed to receiver or synchronized to shelf (called normal mode)

Input Jitter Tolerance:

Per ATT TR 62411

Output Jitter Generation:

Per ATT TR 62411 using normal mode synchronization

Physical Layer Alarms:

LOS, OOF, AIS, RAI

Number of Frame Relay Ports:

1-Single Frame Relay stream occupying n consecutive time slots

Frame Relay Interface Rates:

Either 56 kbps or n * 64 kbps; n as defined previously

Frame Relay Interface:

Per ANSI T1.618, 2-octet header

Frame Relay Performance Counters (per port; n x DS0):

Receive frames discarded due to aborts
Receive frames discarded due to illegal header (EA bit) (S)
Receive frames discarded due to CRC errors (S)
Receive frames discarded due to alignment errors (S)
Receive frames discarded due to unknown DLCI (S)
Receive frames discarded due to illegal frame length (S)
Receive frames discarded due to DE threshold exceeded
Receive frames with DE already set
Receive frames with FECN already set
Receive frames with BECN already set
Receive frames tagged FECN
Receive frames (S)
Receive bytes (S)
Transmit frames discarded due to underrun
Transmit frames discarded due to abort
Transmit frames discarded due to egress Q-depth exceeded (S)
Transmit bytes discarded due to egress Q-depth exceeded (S)
Transmit frames discarded due to egress DE threshold
exceeded transmit frames (S)

 

Transmit bytes (S)
Transmit frames with FECN set (S)
Transmit frames with BECN set (S)

 

LMI receive status inquiry request count (S)
LMI transmit status inquiry request count
LMI invalid receive status count (S)
LMI signaling protocol (keep alive time-out count) (S)
LMI sequence number error count (S)
LMI receive status transmit count (in response to request)
LMI transmit status transmit count (in response to request)
Transmit frames during LMI alarm (S)
Transmit bytes during LMI alarm (S)
LMI update status transmit count (in response to configuration changes)

Diagnostics (per port):

Last unknown DLCI received


System Interface

ATM Layer:

Per CCITT I.361 and ATM UNI v3.1

AAL Layer:

AAL5 per draft CCITT I.363

FR-Cell Interworking:

Per draft CCITT I.555 and I.36x.1, as summarized in
Frame Relay Forum, FR/ATM PVC Interworking Implementation Agreement FRF.5


Virtual Circuits

Channels (Endpoints):

256 per card—can be allocated across any of the Frame Relay interfaces

Counters:

 

Service Counters:

Number of frames received (S)
Number of bytes received (S)
Number of frames received with DE already set (S)
Number of bytes received with DE already set (S)
Number of frames received with unknown DLCI
Number of frames received but discarded (S)
Number of received bytes discarded (S)
Number of received bytes discarded due to exceeded Q-depth (S)
Number of frames received and discarded due to

intershelf alarm exceeded DE threshold (S)

exceeded Q depth (S)

Number of frames received with FECN set
Number of frames received with BECN set
Number of frames received tagged FECN
Number of frames received tagged BECN

 

Number of frames transmitted (S)
Number of bytes transmitted (S)

 

Number of frames transmitted with DE set (S)
Number of frames discarded due to reassembly errors (S)
Number of frames transmitted during LMI logical port alarm (S)
Number of frames transmitted with FECN set (S)
Number of frames transmitted with BECN set (S)
Number of transmit frames discarded (S)
Number of transmit bytes discarded
Number of transmit frames discarded due to: CRC error (S)

egress Q depth exceeded (S)

egress DE threshold exceeded source abort

physical link failure (T1)

ATM cells—Number of cells transmitted to BNM
Number of cells transmitted with CLP bit set
Number of OAM AIS cells transmitted (S)
Number of OAM FERF cells transmitted (S)
Number of BCM cells transmitted
Number of OAM end-end loopback cells transmitted (S)
Number of OAM segment loopback cells transmitted
Number of cells received from BNM
Number of cells received with CLP bit set
Number of OAM AIS cells received (S)
Number of OAM FERF cells received (S)
Number of BCM cells received
Number of OAM end-end loopback cells received (S)
Number of OAM segment loopback cells received
Number of OAM cells discarded due to CRC-10 error (S)

Statistics:

All previous counters followed by an (S) can be configured as statistics

Diagnostics:

Last unknown LCN received cells with unknown LCN count


Card General

Indicators:

 

Per Card:

Active (green), standby (yellow), fail (red)

Lines (one per):

Active and okay (green)
Active and local alarm (red)
Active and remote alarm (yellow)

Maintenance/Serviceability Features:

Internal problem isolation loopbacks hot-pluggable

Reliability:

> 65000 hours MTBF

Card Size:

FRSM-8T1: 7.25 in. x 16.25 in.
LM-DB15-4T1: 7.0 in. x 4.5 in.
Power: -48V DC, 30W (8 T1s)


FRSM-8E1 Specification

Service Interface

Line Interface connector:

RJ-48 when used with LM-RJ-48-8E1 line module SMB when used with LM-SMB-8E1 line module

Line Rate:

2.048 Mbps ± 100 bps

Synchronization:

Transmitter can be either loop-timed to receiver or synchronized to shelf (called normal mode)

Input Jitter Tolerance:

Per G.703

Output Jitter Generation:

Per G.703

Physical Layer Alarms:

LOS, OOF, AIS, RAI

Number of Frame Interfaces:

1 to 31 occupying n where 1 < n < 31. Sum of all < 31 for CCS 1-30 for CAS

Frame Relay Interface Rates:

Either 56 Kbps or n * 64 kbps; n as defined previously

Frame Relay Interface:

Per ANSI T1.618, 2-octet header

Frame Relay Performance Counters (per port; n x DS0):

Receive frames discarded due to aborts
Receive frames discarded due to illegal header (EA bit) (S)
Receive frames discarded due to CRC errors (S)
Receive frames discarded due to alignment errors (S)
Receive frames discarded due to unknown DLCI (S)
Receive frames discarded due to illegal frame length (S)
Receive frames discarded due to DE threshold exceeded
Receive frames with DE already set
Receive frames with FECN already set
Receive frames with BECN already set
Receive frames tagged FECN
Receive frames (S)
Receive bytes (S)

 

Transmit frames discarded due to underrun
Transmit frames discarded due to abort
Transmit frames discarded due to egress Q-depth exceeded (S)
Transmit bytes discarded due to egress Q-depth exceeded (S)
Transmit frames discarded due to egress DE threshold exceeded Transmit frames (S)
Transmit bytes (S)
Transmit frames with FECN set (S)
Transmit frames with BECN set (S)
LMI receive status inquiry request count (S)
LMI transmit status inquiry request count
LMI invalid receive status count (S)
LMI signaling protocol (keep alive time-out count) (S)
LMI sequence number error count (S)
LMI receive status transmit count (in response to request)
LMI transmit status transmit count (in response to request)
Transmit frames during LMI alarm (S)
Transmit bytes during LMI alarm (S)
LMI update status transmit count (in response to configuration changes)

Diagnostics (per port):

Last unknown DLCI received


System Interface

ATM Layer:

Per CCITT I.361 and ATM UNI v3.1

AAL Layer:

AAL5 per draft CCITT I.363

FR-Cell Interworking:

Per draft CCITT I.555 and I.36x.1, as summarized in
Frame Relay Forum, FR/ATM PVC Interworking Implementation Agreement FERF.5


Virtual Circuits

Channels (Endpoints):

256 per card—can be allocated across any of the Frame Relay interfaces

Counters:

 

Service Counters:

Number of frames received (S)
Number of bytes received (S)
Number of frames received with DE already set (S)
Number of bytes received with DE already set (S)
Number of frames received with unknown DLCI
Number of frames received but discarded (S)
Number of received bytes discarded (S)
Number of received bytes discarded due to exceeded Q-Depth (S)
Number of frames received and discarded due to

intershelf alarm

exceeded DE threshold (S)

exceeded Q depth (S)

Number of frames received with FECN set
Number of frames received with BECN set

 

Number of frames received tagged FECN
Number of frames received tagged BECN
Number of frames transmitted (S)
Number of bytes transmitted (S)
Number of frames transmitted with DE set (S)
Number of frames discarded due to reassembly errors (S)
Number of frames transmitted during LMI logical port alarm (S)
Number of frames transmitted with FECN set (S)
Number of frames transmitted with BECN set (S)
Number of transmit frames discarded (S)
Number of transmit bytes discarded
Number of transmit frames discarded due to: CRC error (S)

egress Q depth exceeded (S)

egress DE threshold exceeded source abort physical link failure (T1)

 

ATM cells: Number of cells transmitted to BNM
Number of cells transmitted with CLP bit set
Number of OAM AIS cells transmitted (S)
Number of OAM FERF cells transmitted (S)
Number of BCM cells transmitted
Number of OAM end-end loopback cells transmitted (S)
Number of OAM segment loopback cells transmitted
Number of cells received from BNM
Number of cells received with CLP bit set
Number of OAM AIS cells received (S)
Number of OAM FERF cells received (S)
Number of BCM cells received
Number of OAM end-end loopback cells received (S)
Number of OAM segment loopback cells received
Number of OAM cells discarded due to CRC-10 error (S)

Statistics:

All previous counters followed by an (S) can be configured as statistics.

Diagnostics:

8 Last unknown LCN received
Cells with unknown LCN count
Card general

Indicators:

Per card: Active (green), standby (yellow), fail (red)
Lines (one per): Active and okay (green)
Active and local alarm (red),
Active and remote alarm (yellow)

Maintenance/Serviceability Features:

Internal problem isolation loopbacks
Hot-pluggable

Card Size:

FRSM-8E1: 7.25 in. x 16.25 in.
RJ48-8E1: 7.0 in. x 4.5 in.
SMB-8E1: 7.0 in. x 4.5 in.

Power:

-48V DC, 30W (8 E1s)

Ingress:

8000 cell buffer shared between virtual channels/paths
Standard usage parameter control (UPC)
Selective cell discard
Virtual circuit queuing
EFCI setting per VC

Egress:

8000 cell storage capacity shared between four ports
Up to 12 user selectable egress queues per port
Selective cell discard
EFCI setting per queue


FRSM-HS2 Specification

Errors and Alarm Handling

Line Alarms

Control lead inactive

Recovered clock does not match configured line rate

External Interface Specification

General

Frame Relay Interface: Per ANSI T1.618, 2-octet header

ATM layer: Per CCITT I.361 and ATM UNI v3.1

AAL layer: AAL5 per Draft CCITT I.363.

FR-cell interworking: Per Draft CCITT I.555 and I.36x.1, as summarized in ATM-to-Frame Relay Interoperability Implementation Agreement v 1.0

Physical Interface Specification

FRSM-VHS Front Card

Card status indicator LEDs

Active (green)

Failed (red)

Standby (yellow)

Line status indicator LEDs

Active and okay (green)

Active and local alarm (red)

Active and remote alarm (yellow)

Reliability 85000 hours MTBF (target)

Card size 7.25 in. x 16.5 in.

Power 48V DC, 50W (estimate)

FRSM-HS2 Back Card

Power: 5W @ 5V; 6W C @ -5V

FRSM-HS2 Line

Number of HSSI lines 2

Line interface connector SCSI-2

Line framing not applicable

Synchronization: Transmitter can be either loop-timed to receiver (DTE mode), or synchronized to shelf, (DCE mode)

Input jitter tolerance

Output jitter

Statistics and Counters Specifications

FRSM-HS2

Counters (per line)

Receive frames lost due to aborts
Receive frames lost due to illegal header (EA bit)
Receive frames lost due to CRC errors
Receive frames with bit alignment errors
Receive frames with unknown DLCI
Receive frames with illegal frame length
Receive good frame
 
Transmit frames lost due to under-run/Abort count
Transmit good frame
 
LMI status inquiry request count
LMI signaling protocol (keep alive time-out count)
LMI sequence number error count
LMI status transmit count (in response to request)
LMI update status transmit count (in response to configuration changes
 
Frames FECN set count
Frames BECN set count
DE frames discarded count
 
Number of frames reassembled but discarded due to service
interface physical layer alarm
Trouble shooting statistics:
ECN current queue depth (per channel)
   
   

Statistics
Service: Number of frames received
Number of bytes received
Number of frames received with DE = 1
Number of frames received but discarded
Number of received bytes discarded
Number of frames received but discarded due to:
- CRC error
- Illegal frame length
- Alignment error
- Abort
Number of frames reassembled and transmitted
Number of frames reassembled and transmitted with DE=1
Number of frames discarded due to reassembly errors
Number of frames transmitted
Number of bytes transmitted
Number of frames transmitted with DE set
Number of frames transmitted during LMI logical port alarm
Frames FECN set count
Frames BECN set count
Number of transmit frames discarded
Number of transmit bytes discarded
Number of transmit frames discarded due to:
- CRC error
- Illegal frame length
- Alignment error
- Abort
- Exceeding DE egress queue threshold
- Physical link failure
ATM cells: Number of cells transmitted to BNM
Number of cells discarded due to intershelf link alarm
Number of cells transmitted with CLP bit set
Number of AIS cells transmitted
Number of FERF cells transmitted
Number of BCM cells transmitted
Number of end-end loop-back cells transmitted
Number of segment loop-back cells transmitted
Number of cells received from BNM
Number of cells received with CLP bit set
Number of AIS cells received
Number of FERF cells received
Number of BCM cells received
Number of end-end loop-back cells received
Number of segment loop-back cells received
Number of OAM cells discarded due to CRC-10 error
Diagnostics: Header of last cell with unknown LCN
Header of last received frame with unknown DLCI
ECN current queue depth

AUSM Specification (4 Port)

Service Interface (T1)

Line Interface Connector:

Miniature 15 pin female DB-15 (100 W)—(Use LM-DB15-4T1)

Line Rate:

1.544 Mbps ± 50 bps (T1)

Synchronization:

Transmitter can be either loop-timed or receiver, or synchronized to shelf (called normal mode)

Line Code:

Bipolar 8 zero substitution (B8ZS) as specified in ANSI T1.408 (T1)

Line Framing:

Extended superframe format (ESF 24 frame multiframe) as ANSI T1.408

ESF Maintenance Functions:

Bit-oriented alarm and loopback messages of ESF Data Link as per ANSI T1.408

Input Jitter Tolerance:

Per ATT TR 62411

Output Jitter Generation:

Per ATT TR 62411 using normal mode synchronization

Physical Layer Alarms:

LOS, OOF, AIS, RAI

Physical Layer Performance Stats:

LCV, LES, LSES, CV, ES, SES, SEFS, AISS, UAS


Service Interface (E1)

Line Interface Connector:

Miniature 15 pin female DB-15 (120 W)—(Use LM-DB15-4E1), BNC (75 W)—(Use LM-BNC-4E1)

Line Rate:

2.048 Mbps ± 100 bps (E1)

Synchronization:

Transmitter can be either loop-timed or receiver, or synchronized to shelf (called normal mode)

Line Code:

HDB3 (E1)

Line Framing:

16 frame Multiframe as in G.704

Input Jitter Tolerance:

As specified in ITU G.823 for 2.048 mbps

Output Jitter Generation:

As specified in ITU G.823 for 2.048 mbps

Physical Layer Alarms:

LOS, OOF, AIS, RAI

Physical Layer Performance Stats:

LCV, LES, LSES, CV, ES, SES, SEFS, AISS, UAS


ATM Interface

 

ATM UNI v3.1, ITU-T G.804, per CCITT I.361

Channel Configuration:

256 per card. Can be allocated across any of the T1 (E1) ports

VPI/VCI:

VPI: 0-255
VCI: 0-4096

Traffic Classes:

CBR, VBR, VBR+

UPC Parameters:

PCR, SCR (VBR), CCDV (CBR)

Congestion Control Support:

ForeSight (toward Network for VBR+)

ForeSight Parameters:

MIR, PIR, Rate Up, Rate Down, QIR, QIR Timeout, IBS


Virtual Circuits

Counters:

 

Per Port:

Number of cells received from the interface
Number of cells received with unknown VPI/VCI
Last known VPI/VCI received from the port
Number of cells discarded due to error in cell header
Number of cells received with nonzero GRC field
Number of cells transmitted to the interface
Number of cells transmitted for which EFCI was set
Number of egress cells discarded due to service interface physical alarm

  Endpoint (channel):

 

Ingress:

Number of cells received from port
Number of cells received from the port with CLP = 1
Number of cells received from the port with EFCI = 1
Number of cells from the port discarded due to queue exceeded QDepth
Number of cells (with CLP) set) discarded due to queue exceeded CLP threshold
Number of cells from the port for which CLP was set due to UPC violations

ATMizer channel counters:

 

Ingress:

Number of cells transmitted to cell bus
Number of cells to cell bus for which EFCI was set
Number of cells to cell bus discarded due to shelf alarm

Egress:

Number of cells received from the cell bus
Number of cells discarded due to queue exceeded QDepth (per egress Q)
Number of cells discarded due to queue exceeded CLP threshold (per egress Q)
Number of cells received with CLP = 1

Other Counters:

.

Ingress:

Number of OAM cells discarded
Number of AIS cells received from the port
Number of RDI (FERF) cells received from the port
Number SegmentLpBk cells received from the port
Number of SegmentLpBk cells transmitted to cell bus

Egress:

Number of OAM cells discarded
Number of AIS cells transmitted to the port
Number of SegmentLpBk cells transmitted to the port
Number of SegmentLpBk cells received from the port

Diagnostic Stats:

Peak Queue Depth (Ingress: per channel)


Card General

Indicators:

 

Per Card:

Active (green), standby (yellow), fail (red)

Per Line:

One per line: Active and okay (green)
Active and local alarm (red)
Active and remote alarm (yellow)

Maintenance/Servicability:

Facility loopback using loop up/down per ANSI T1.408 and ATT TR 62411 (T1), CCITT G.7xx (E1)
Facility loopback using management console
Internal problem isolation loopbacks
Hot pluggable

Card Size:

7.25 in. x 15 in.

Power:

-48V DC, 30W

Safety:

EN 60950 2nd edition (including EN 41003) UL 1950 2nd edition

Compliance:

T1: Accunet 62411 E1: G.703, G.823

ESD:

IEC 1000-4-2


CESM-4T1/E1 Specification


Note The CESM-4T1/E1 specification is the same as the FRSM-4T1/4E1 specification except as shown in the following sections.


Service Interface (T1/E1)

Synchronization:

Transmitter is synchronized to the shelf (Stratum traceable)

Line Framing:

None

Channel Configuration:

 

Number of CBR Interfaces:

4

Cell Delay Variation (CDV):

Configurable by setting reassembly buffer depth to a maximum of 250 msec. CDV = 1/2 buffer depth


Virtual Circuits

Channels (Endpoints):

One per physical port

Counters:

 

MIB Name

 AAL1:

   
 

Number of lost SAR-PDUs
Number of buffer overflow events
Number of buffer underflow events
Number of SAR-PDU's with header error
Number of SAR-PDU's received out of sequence
Number of cells played out to T1/E1 port
Number of cell generated from T1/E1 port
Number of bytes discarded due to shelf alarm from port
Number of all 1's cells inserted during buffer underflow
Number of bytes discarded due to egress overflow

cesLostCells
cesBufOverflows
cesBufUnderflows
cesHdrErrs
cesCellSeqMismatchCnt
cesReassCells
cesGenCells
cesIngrDiscardedBytes

cesUflowInsCells

cesOflowDropBytes

Diagnostic:

Egress buffer depth (per port)

 

Alarms:

 

MIB Name

T1/E1 Port:

Red, loss of signal (LOS)

Blue, alarm indication signal (AIS)

LineAlarmState—bit 5 set

LineAlarmState—bit 2 set and cesChanState = 3

 

Line code violation (LVC)

LineStatisticalAlarmState

SAR Port:

   

Transmit State:

SendingAIS

Sending FERF

cesXmtATMState = 3

cesXmtATMState = 4

Receiving State:

   
 

Receiving AIS

Receiving FERF

Cell loss

cesRcvATMstate = 3

cesRcvATMstate = 4

cesCellLossStatus = 2



Note All service specific alarms, except red, are passed through transparently.

Loss of signal (red) at CBR interface results in all 1's cells being transmitted.

Brief periods of cell loss "Starvation" results in insertion of 47 octects of 1's.

Extended periods of cell loss results in all 1's (unframed AIS) being generated.

During periods of cell bus configuration SAR-PDUs are discarded.


MATM Specification

Physical Interface (T3.T1) RJ48-T3T1-LM

 

T1 Line Interface Connector:

Miniature RJ-48C, 100 ohms balanced

T3 Line Interface Connector:

BNC, 75 ohms unbalanced

Physical Interface (E3.E1) RJ48-E3E1-LM:

 

E1 Line Interface Connector:

Miniature RJ-48C, 100 ohms balanced

E3 Line Interface connector:

BNC, 75 ohms unbalanced

Physical Interface (E3.E1B) SMB-E3E1-LM:

 

E1 Line Interface Connector:

Miniature SMB, 75 ohms unbalanced

E3 Line Interface Connector:

Miniature SMB, 75 ohms unbalanced


Physical Layer Interface T1:

Line Rate:

1.544 Mbps ± 50 bps

IMATM Synchronization:

Digital PLL to synchronize all transmitters to one of the following: the T3 line, any of the T1 lines, or the MGX 8220 shelf 8 kHz clock

Line Code:

Bipolar 8 zero substitution (B8ZS) as specified in ANSI T1.408

Line Framing:

Extended Superframe Format (ESF 24 frame multiframe) as in ANSI T1.408

Input Jitter Tolerance:

Per ATT TR 62411

Output Jitter Generation:

Using normal mode synchronization per ATT TR 62411

Physical Layer Alarms:

LOS, OOF, AIS, RDI

Physical Layer Performance Parms:

LCV, LES, LSES, CV, ES, SES, SEFS, AISS, UAS


Physical Layer Interface E1

Line Rate:

2.048Mbps ± 100 bps

IMATM Synchronization:

Digital PLL to synchronize all transmitters to one of the following: the E3 line, any of the E1 lines, or the MGX 8220 shelf 8 kHz clock

Line Code:

HDB3 (E1)

Line Framing:

16 frame multiframe as in G.704

ESF Maintenance Functions:

None

Input Jitter Tolerance:

As specified in ITU G.823 for 2.048 mbps

Output Jitter Generation:

As specified in ITU G.823 for 2.048 mbps

Physical Layer Alarms:

LOS, OOF, AIS, RDI

Physical Layer Performance Parms:

LCV, LES, LSES, CV, ES, SES, SEFS, AISS, UAS


Physical Layer Interface T3

Line Rate:

44.736 Mbps ± 20 ppm (T3)

Line Code:

B3ZS for DS3

Framing:

Physical layer conversion procedure for DS3 to ANSI TA-TSY-000772 and TA-TSY-000773

Input Compliance:

Per ATT 54014 and CCITT G.703


Physical Layer Interface E3

Line Rate:

34.368 Mbps ±20 ppm (T3)

Line Code:

HDB3 for E3

Framing:

Per ITU-T Recommendation G.804 and G.832

Input Jitter Tolerance:

Per ATT TR 62411

ATM Interface:

 

Cell support (type)

STI cells

Congestion Control:

EFCI/FFCI setting on egress (AIM)

EFCI setup:

Using programmable EFCI threshold

IMATM Alarms:

Complies with DS3 and G.832 physical layer protocols and supports FERF, LOS, LOF, OOF, AIS, yellow and red alarms


AIM Groups and Links

Counters:

 

High Speed Port:

DS3/E3 physical layer line alarm indication and insertion
DS3/E3 SUNI-PDh number of cells: Tx and Rx
PLL clock recovery status

AIM Group:

Number of cells received from AIM interface
Number of cell discarded due to error in cell header
Number of cells from AIM interface discarded due to queue Full on both Ingress and egress directions
Number of ACP cells received
Number of ACP cells received with errors
Number of LCP cells received
Number of LCP cells received with errors

 

Number of cells served from Egress queue to AIM interface
Number of cell transmitted by trunk interface, two types: Date and Filler + Data
Number of times a link went off the IMAIM group

ATMizer (cellbus) counters:

 

Ingress:

Numberof cells transmitted
Number of cells discarded due to shelf alarm

Egress:

Number of cells received
Numberof cells discarded due to queue depth exceeded Q-Depth


Card General

Indicators:

 

Per Card:

Active (green), standby (yellow), fail (red)

Lines (one per):

Active and okay (green)
Active and local alarm (red)
Active and remote alarm (yellow)

Maintenance/Serviceability Features:

Internal problem isolation loopbacks
Hot-pluggable

Card Size:

IMATM front card: 7.25 in. x 16.25 in.
RJ48-T3T1-LM: 7.0 in. x 4.5 in.
RJ48-E3E1-LM: 7.0 in. x 4.5 in.
SMB-E3E1-LM: 7.0 in. x 4.5 in.

Power:

-48V DC