This appendix lists preliminary information for Release 8.5. (Refer to on-line documents for latest information.)
Trunk Interfaces: | T3 and E3 |
Trunk Protocol: | Asynchronous Transfer Mode (ATM) |
Trunks per Node: | 32 DS3 or E3 trunks per BPX of which 16 can be shelf trunks 1 active DS3 or E3 trunk per IPX |
Trunk Bandwidth: | 96,000 cells/sec. (T3) 80,000 cells/sec. (E3)
|
Trunk Interfaces: | OC3 |
Trunk Protocol: | Asynchronous Transfer Mode (ATM) |
Trunks per Node: |
|
Trunk Bandwidth: | 353,208 cells/sec (OC3)) |
Trunk Interfaces: | OC12 |
Trunk Protocol: | Asynchronous Transfer Mode (ATM) |
Trunks per Node: |
|
Trunk Bandwidth: | 1,412,830 cells/sec |
North American: | T1 Fractional T1 (minimum of 4 DS0s) T2 |
International: | CEPT E1 Subrate, 64 Kbps to 1.920 Mbps Japanese "Y1" |
Trunk Bandwidth: | 1.536 Mbps, 8,000 FastPackets/sec. (T1) 1.984 Mbps, 10,333 FastPackets/sec. (framed E1) 2.048 Mbps, 10,666 FastPackets/sec. (unframed E1) Subrate and fractional T1 depend on data rate selected |
Frame Relay: | Channelized T1: 56 Kbps, N x 64 Kbps, up to 1.536 Mbps. Channelized E1: G.703, N x 64 Kbps, up to 1.984 Mbps. V.35: configurable from 56 Kbps to 2.048 Mbps |
Data: | V.35: 56 Kbps to 1.344 Mbps. RS-449: 56 Kbps to 1.344 Mbps. |
Voice: | Channelized T1 Channelized E1 Channelized Japanese "TTC" DC5A and E&M channel associated signaling FAX/high-speed modem |
Characteristic: | T3 (DS3) | E3 |
Line Rate | 44.736 Mbps +/- 20 ppm | 34.368 Mbps +/- 20 ppm |
Line Code | B3ZS | HDB3 |
Cell Transfer Rate | 96,000 cells per second | 80,000 cells per second |
Framing | ANSI T1.107, T1.107a | ITU T G804, G.832 |
Signal Level | TA-TSY-000773 (PLCP) | ITU-T G.703 |
Transmission Convergence Sublayer | DS3 PLCP frame format DS3 HEC mapped format | G.832 E3 frame format |
| T3 (DS3) and E3 | |
Port Interface | Trunk or UNI | |
ATM Layer Protocol | LMI, ILMI | |
Port Alarm Processing | LOS, LOF | |
Connector | SMB | |
Indicators | Card status, Port status |
Line Rate | 155.52 Mbps |
|
|
Line Code | NRZ |
|
|
Signal Level | Min dBm | Max dBM |
|
MMF LED TX | -22 | -15 |
|
MMF LED RX | -34 | -10 |
|
SMF IR TX | -15 | -8 |
|
SMF IR RX | -34 | -10 |
|
SMF LR TX | -5 | 0 |
|
SMF LR RX | -34 | -10 |
|
Framing Format: | STS-3c, STM-1 |
| |
Port Interface: | LMI, ILMI |
| |
ATM Cell Rate: | 353,208 cells/sec. |
| |
Jitter: | ATM Forum UNI 3.1 |
| |
ATM Layer Protocol: | LMI, ILMI |
| |
Port Alarm Processing: | LOS, LOF, LOP, Path AIS, Path Yellow |
| |
Line Errors Counted: |
|
| |
Connector: | SC for MMF, FC-PC for SMF (IR) and SMF (LR) |
| |
Max. Cable Lengths: | MMF ~2 KM |
| |
| SMF IR ~20 KM |
| |
| SMF LR ~40 KM |
| |
Indicators: | Card status, Port status. |
|
Line Rate | 622.08 Mbps |
|
Line Code | NRZ |
|
Signal Level | Min dBm | Max dBM |
SMF IR TX | -15 | -8 |
SMF IR RX | -28 | -8 |
SMF LR TX | -2 | +2 |
SMF LR RX | -28 | -8 |
Framing Format: | STS-12c, STM-4 | |
Port Interface: | LMI, ILMI | |
ATM Cell Rate: | 1,412,830 cells/sec. | |
Jitter: | ATM Forum UNI 3.1 | |
ATM Layer Protocol: | LMI, ILMI | |
Port Alarm Processing: | LOS, LOF, LOP, Path AIS, Path Yellow | |
Line Errors Counted: |
| |
Connector: | SMF-FC | |
Max. Cable Lengths: | MMF ~2 KM | |
| SMF IR ~20 KM | |
| SMF LR ~40 KM | |
Indicators: | Card status, Port status. |
Line Rate: | 44.736 Mbps ±20 ppm, asynchronous |
Line Code: | B3ZS |
Signal Level: | DSX-3 |
Framing Format: | C-bit parity is monitored. No other framing or control bits in the DS3 frame are either altered or monitored |
Protocol: | Physical Layer Convergence Protocol per AT&T Publication TA-TSY-000772 and 000773 |
ATM Cell Rate: | 96,000 cells/sec. Limited to 80,000 cells/sec. when interfacing with the IPX |
Alarms Sent: | AIS |
Alarms Received: | AIS |
Line Errors Counted: | BPV. |
Jitter: | Meets ACCUNET T45 specification (Pub 54014) |
Connector: | 75 ohm BNC |
Recommended Cable Lengths: | 900 feet (275 m.) max. using specified cable |
Indicators: | Card status Port status |
Line Rate: | 34.368 Mbps ± 20 ppm, asynchronous |
Line Code: | HDB3 |
Signal Level: | CCITT G.703 |
Framing Format: | CCITT G.804, G.832 |
Port Interface: | 75 ohm unbalanced |
Barrier: | Fully barriered per EN 41003 |
ATM Cell Rate: | 80,000 cells/sec |
Jitter: | per CCITT G.823 |
ATM Layer Protocol: | per CCITT I.361 with HEC |
Port Alarm Processing: | AIS |
Line Errors Counted: | BPV. |
Connector: | 75 ohm BNC |
Max. E3 Cable Lengths: | 900 feet (275 m.) using specified cable |
Indicators: | Card status |
Line Rate: | 155.52 Mbps |
|
Line Code: | NRZ |
|
Signal Level: | Max | Min |
MMF TX | -8 dBm | -15 dBm |
MMF RX | -8 dBm | -28 dBm |
SMF LR TX | 0 dBm | -5 dBM |
SMF LR RX | -10 dBm | -34 dBm |
Framing Format: | STS-3c, STM1 |
|
Port Interface: | LMI, ILMI |
|
ATM Cell Rate: | 353,208 cells/sec |
|
Jitter: | < 0.01 UI p-p, < 0.1 UI rms |
|
ATM Layer Protocol: | LMI, ILMI |
|
Port Alarm Processing: | LOS, LOF, LOP, Path AIS, Path Yellow | |
Line Errors Counted: | Section BIP8, Line BIP24, Line FEBE, Path BIP8, Path FEBE | |
Connector: | MMF SC SMF FC/PC |
|
Max. Cable Lengths: | MMF ~ 2 KM SMF IR ~20 KM SMF LR ~40 KM |
|
Indicators: | Card status Port status |
|
Capacity: | 8 or 12 ports per card. |
Interface: | DS3/T3 or E3 |
Line Rate: | DS3 44.736 Mbs, E3 34.368 Mbps |
No. of channels per card: | 16,000 |
No. of channels per node: |
|
VPI Addressing Range: | ATM UNI 3.1 compliant |
VCI Addressing Range: | ATM UNI 3.1 compliant |
Queues: | 16 COS with 32 Virtual Interface (VI) queues |
Capacity: | 4 or 8 ports per card. |
Interface: | OC-3c/STM-1 |
Line Rate: | 155.52 Mbps |
No. of channels per card: | 16,000 |
No. of channels per node: |
|
VPI Addressing Range: | ATM UNI 3.1 compliant |
VCI Addressing Range: | ATM UNI 3.1 compliant |
Queues: | 16 COS with 32 Virtual Interface (VI) queues |
Capacity: | 2 ports per card. |
Interface: | OC-12c/STM-4 |
Line Rate: | 622.08 Mbps |
No. of channels per card: | 16,000/32,000 |
No. of channels per node: |
|
VPI Addressing Range: | ATM UNI 3.1 compliant |
VCI Addressing Range: | ATM UNI 3.1 compliant |
Queues: | 16 COS with 32 Virtual Interface (VI) queues |
Capacity: | 2 ports per card |
Interface: | T3 |
Line Rate: | 96,000 cells/sec |
No. of channels per card: | 1000 |
No. of channels per node: | 1000 or 5000 (grouped) |
VPI Addressing Range: | 0-255 (UNI), 0-1023 (NNI) |
VCI Addressing Range: | 1-4095 |
Queues: | 32, 16 per line (port) includes CBR, VBR, and ABR queues. |
Capacity: | 2 ports per card. |
Interface: | E3 |
Line Rate: | 80,000 cells/sec. |
No. of channels per card: | 1000 |
No. of channels per node: | 1000 or 5000 (grouped) |
VPI Addressing Range: | 0-255 (UNI), 0-1023 (NNI) |
VCI Addressing Range: | 1-4095 |
Queues: | 32, 16 per line (port) includes CBR, VBR, and ABR queues. |
Capacity: | 2 ports per card. |
Interface: | OC3 |
Line Rate: | 353,208 cells/sec. |
No. of channels per card: | 1000 |
No. of channels per node: | 1000 or 5000 (grouped |
VPI Addressing Range: | 0-255 (UNI), 0-1023 (NNI) |
VCI Addressing Range: | 1-4095 |
Queues: | 24, 12 per line (port) includes CBR and VBR queues |
Network Clock: | One clock source per domain must be defined. Network clock cannot propagate across domain boundary. |
Node Clock: | 44.736 MHz, ±50 Hz (Stratum 3 per AT&T Pub 62411). Internal 8 KHz and 192 KHz clocks for synchronizing network interfaces. |
Clock Sources: | Internal, free-running oscillator. Phase-locked to any appropriate network interface. External input at T1 or E1 rate. |
Clock Output: | Single clock output at T1 or E1 rate for synchronizing co-located IPX node(s) or CPE. |
Clocking Hierarchy: | Network-wide or domain-wide (for structured networks) clock selection. |
NMS Terminal: | SUN Microsystems and StrataView Plus, Informix, Wingz, and HP OpenView software required for network management, connection provisioning, graphical display of network status, statistics gathering and display, automatic downloading of switch software, and save and restore of node configurations. |
Control Terminal: | DEC VT100 or equivalent terminal for basic system configuring and alarm monitoring. |
Remote Alarm Reporting: | Autodial modem may be connected to the auxiliary port on one or more IPX or IGX nodes for automatic reporting of network alarms. |
Remote Diagnostics: | Autoanswer modem may be connected to the control port one or more IPX, IGX, or BPX nodes for remote diagnostic access by Cisco Customer Service or other authorized personnel. |
Network Control Ports: | Three ports per node, two with RS 232C interface, one with Ethernet LAN interface. (Nodes with PCC controller have only the two RS-232 ports). |
Alarm Notification: | Status of all trunks and nodes in network distributed to and stored by each individual node. Reported to StrataView Plus terminal at connecting node. |
External Alarms: | Meets Bellcore Compatibility Bulletin #143 and AT&T Technical Reference PUB 43801 DS1 (T1) facility alarm requirements. |