cc/td/doc/product/wanbu/bpx8600/9_3_1
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

BPX Node Specifications

BPX Node Specifications

This chapter lists information for the BPX system specifications. For the latest information, refer to Cisco online documents.

System Capacity:

1 shelf with 15 card slots.
Requires 1 or 2 dedicated slot(s) for BCC card.
Requires 1 dedicated slot for ASM card.

Network Interface:

T3, E3, OC3, and OC12.

Network Trunks:

32 per node max.

Network Interface Protocol:

ATM layer using 53-byte cell.

Cell Switching:

Crosspoint switch matrix, non-blocking.

Switch Capacity:

9.6 Gbps or 19.2 Gbps (with BCC-4).

Slot Rate:

800 Mbps each, including overhead.

Connection Rate:

20 million cell connections/sec. between slots.

Classes of Service:

32 queues per port, assignable.

Clock Sources:

Internal, free-running oscillator, Stratum 3.

Phase-locked to any appropriate network interface.

External input at T1 or E1 rate.

Clock Output:

Single clock output at T1 or E1 rate for synchronizing co-located IGX node or CPE.

Cabinet Size:

22.75 inches (57.8 cm) high
19.0 inches (48.25 cm) wide
27.0 inches (68.6 cm) deep

Weight, approx:

73 lb. (33.2 kg.) empty BPX shelf, w/fans but no PS.
6 lb. (2.7 kg.) each card.
18 lb. (8.2 kg.) empty AC Power Supply Tray.
16 lb. (7.3 kg.) each AC Power Supply.
2 lb. (0.9 kg.) each DC Power Entry module.

Clearance Requirement:

At least 30 inches front and rear clearance; nominal 12 inch side clearance.

Power Source:

AC system: 180 - 264 VAC, 47 to 63 Hz.
DC system: -42 to -56 VDC.

Power Requirements:

AC BPX-15: 13 A at 180 VAC (2300 VA).
DC BPX-15: 40 A at -42 VDC (1680W).

Input Power Connector:

AC: 3-conductor IEC receptacle. 8 feet (2.4 m.) power cord supplied.
DC: 3 Ring lug screw terminal connectors.

Circuit Breakers:

AC: 15 A on AC power supply assembly.
DC: 40A on power entry module.

Fuses:

Individual Backplane Card slot fuses, F1 through F3 for Fans 1 through 3, and F4 through F18 for card slots 1 through 15, 5A-120VAC rating.

Operating Environment:

Operating Conditions are listed in Table 30-1.

Shock:

Withstands 10G, 10 ms. at 1/2 sine wave.

Vibration:

Withstands 1/4 G, 20-500 Hz.

Heat Transfer to Room:

Up to 7200 BTUs depending on node configuration.


Table 30-1: Ambient Temperature and Humidity Limits
Conditions Limits
Fahrenheit Centigrade

Operating Temperature

Recommended

+40 to +100 degrees

+68 to + 86 degrees

+4.5 to +38 degrees

+20 to +30 degrees

Short-Term Temperature1

+35 to +120 degrees

+1.7 to + 49 degrees

Operating Relative Humidity

20% to 55%

(non-condensing)

Short-Term Relative Humidity

10% to 80%

non-condensing

1Room temperature refers to conditions at a location 5 feet above the floor and 15 inches in front of the equipment.

ATM Trunk Interface (BXM-T3/E3 Cards)

Characteristic T3 (DS3) E3

Line Rate:

44.736 Mbps +/- 20 ppm

34.368 Mbps +/- 20 ppm

Line Code:

B3ZS

HDB3

Cell Transfer Rate:

96,000 cells per second (PLCP mode)

104268 cells per second (HEC/Direct mode)

80,000 cells per second

Framing:

ANSI T1.107, T1.107a

ITU T G804, G.832

Signal Level:

TA-TSY-000773 (PLCP)

ITU-T G.703

Transmission Convergence Sublayer:

DS3 PLCP frame format

DS3 HEC mapped format

G.832 E3 frame format

T3 (DS3) and E3

Port Interface, trunk mode,

-framing:

Framing for T3, C bit parity per ANSI T1.107/107A

-port alarm processing

RDI (yellow alarm) and AIS

Port Interface, port (UNI) mode:

ATM Layer Protocol:

LMI, ILMI

Port Alarm Processing:

LOS, LOF

Connector:

SMB

ATM Trunk Interface (BXM-15zM-622 Cards)

Line Rate:

622.08 Mbps

Line Code:

NRZ

Signal Level:

Min dBm

Max dBM

SMF IR TX

-15

-8

SMF IR RX

-28

-8

SMF LR TX

-2

+2

SMF LR RX

-28

-8

Framing Format:

STS-12c, STM-4

Port Interface:

LMI, ILMI

ATM Cell Rate:

1,412,830 cells per second

Jitter:

ATM Forum UNI 3.1

ATM Layer Protocol:

LMI, ILMI

Port Alarm Processing:

LOS, LOF, LOP, Path AIS, Path Yellow

Line Errors Counted:

Connector:

SMF-FC

Max. Cable Lengths:

SMF IR ~20 KM

SMF LR ~40 KM

Indicators:

Card status

Port status

ATM T3 Trunk Interface (BNI-T3, LM-3T3)

Line Rate:

44.736 Mbps ± 20 ppm, asynchronous

Line Code:

B3ZS

Signal Level:

DSX-3

Framing Format:

C-bit parity is monitored. No other framing or control bits in the DS3 frame are either altered or monitored.

Protocol:

Physical Layer Convergence Protocol per AT&T Publication TA-TSY-000772 and 000773

ATM Cell Rate:

96,000 cells per second

Alarms Sent:

Remote

Alarms Received:

AIS
Loss of Signal
Remote
Loss of Framing

Line Errors Counted:

BPV
Parity Bit Errors

Jitter:

Meets ACCUNET T45 specification (Pub 54014)

Connector:

75 ohm BNC

Recommended Cable Lengths:

450 feet (150 m.) to a DS3 crossconnect

Indicators:

Card status
Port status

ATM E3 Trunk Interface (BNI-E3, LM-3E3)

Line Rate:

34.368 Mbps ± 20 ppm, asynchronous

Line Code:

HDB3

Signal Level:

CCITT G.703

Framing Format:

CCITT G.804, G.832

Port Interface:

75 ohm unbalanced

Barrier:

Fully barriered per EN 41003

ATM Cell Rate:

80,000 cells/sec

Jitter:

per CCITT G.823

ATM Layer Protocol:

per CCITT I.361 with HEC

Port Alarm Processing:

AIS
Loss of Signal
Remote Alarm Indication
Loss of Framing

Line Errors Counted:

BPV
Parity Bit Errors

Connector:

75 ohm BNC

Max. E3 Cable Lengths:

100 meters. Cabling must not exceed -6 dB/1000 feet at E3 rates. Cisco supplies cable with a maximum attenuation of 7 dB/1000 feet, but the maximum cable length must not exceed 100 meters.

Indicators:

Card status
Port status

ATM OC3 Trunk Interface (BNI-OC3, LM-OC3)

Line Rate:

155.52 Mbps

Line Code:

NRZ

Signal Level:

Max

Min

MMF TX

-8 dBm

-15 dBm

MMF RX

-8 dBm

-28 dBm

SMF LR TX

0 dBm

-5 dBM

SMF LR RX

-10 dBm

-34 dBm

Framing Format:

STS-3c, STM1

Port Interface:

LMI, ILMI

ATM Cell Rate:

353,208 cells/sec.

Jitter:

< 0.1 UI p-p, < 0.01 UI rms

ATM Layer Protocol:

LMI, ILMI

Port Alarm Processing:

LOS, LOF, LOP, Path AIS, Path Yellow

Line Errors Counted:

Section BIP8, Line BIP24, Line FEBE, Path BIP8, Path FEBE

Connector:

MMF SC

SMF FC/PC

Max. Cable Lengths:

MMF ~2 KM
KM SMF IR ~20
KM SMF LR ~40 KM

Indicators:

Card status
Port status

ATM Service Interface (BXM-T3/E3 Cards)

Capacity:

8 or 12 ports per card

Interface:

DS3/T3/E3

Line Rate:

DS3 44.736 Mbs, E3 34.368 Mbps

No. of channels per card:

16,000

No. of channels per node:

VPI Addressing Range:

ATM UNI 3.1 compliant

VCI Addressing Range:

ATM UNI 3.1 compliant

Queues:

16 COS with 32 Virtual Interface (VI) queues

ATM Service Interface (BXM-155 Cards)

Capacity:

4 or 8 ports per card

Interface:

OC-3c/STM-1

Line Rate:

155.52.08 Mbps

No. of channels per card:

16,000

No. of channels per node:

VPI Addressing Range:

ATM UNI 3.1 compliant

VCI Addressing Range:

ATM UNI 3.1 compliant

Queues:

16 COS with 32 Virtual Interface (VI) queues

ATM Service Interface (BXM-622 Cards)

Capacity:

2 ports per card

Interface:

OC-12c/STM-4

Line Rate:

622.08 Mbps

No. of channels per card:

16,000/32,000

No. of channels per node:

VPI Addressing Range:

ATM UNI 3.1 compliant

VCI Addressing Range:

ATM UNI 3.1 compliant

Queues:

16 COS with 32 Virtual Interface (VI) queues

ATM Service Interface (ASI-1, LM-2T3)

Capacity:

2 ports per card

Interface:

T3

Line Rate:

96,000 cells/sec.

No. of channels per card:

1000

No. of channels per node:

1000 or 5000 (grouped)

VPI Addressing Range:

0-255 (UNI), 0-1023 (NNI)

VCI Addressing Range:

1-4095

Queues:

32, 16 per line (port) includes CBR, VBR, and ABR queues

ATM Service Interface (ASI-1, LM-2E3)

Capacity:

2 ports per card

Interface:

E3

Line Rate:

80,000 cells/sec.

No. of channels per card:

1000

No. of channels per node:

1000 or 5000 (grouped)

VPI Addressing Range:

0-255 (UNI), 0-1023 (NNI)

VCI Addressing Range:

1-4095

Queues:

32, 16 per line (port) includes CBR, VBR, and ABR queues

ATM Service Interface (ASI-2, LM-OC3)

Capacity:

2 ports per card

Interface:

OC3

Line Rate:

353,208 cells/sec.

No. of channels per card:

1000

No. of channels per node:

1000 or 5000 (grouped)

VPI Addressing Range:

0-255 (UNI), 0-1023 (NNI)

VCI Addressing Range:

1-4095

Queues:


hometocprevnextglossaryfeedbacksearchhelp
Posted: Fri Jul 27 18:00:39 PDT 2001
All contents are Copyright © 1992--2001 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.