This chapter describes the ATM commands that let you activate and configure ATM connections as well as statistical reporting for these connections at an ATM UNI in a BPX or IGX node. You can add ATM connections to an ASI or BXM in a BPX node, or to an ALM/A or UXM in an IGX node. Table 9-1 lists the ATM UNI card combinations for BPX and IGX nodes. For details on ATM commands and other support on an MGX 8220 shelf, refer to the MGX 8220 documentation. For details on ATM commands on an MGX 8550 shelf, refer to the MGX 8550 documentation.


Table 9-1: ATM UNI Cards
Front Card Back Card

ALM/A

BC-UAI-1T3 or BC-UAI-1E3

ASI-T3

LM-2T3 (Two ports)

ASI-E3

LM-2E3 (Two ports)

ASI-155

MMF-2-BC, SMF-2-BC, or SMF LR-2-BC

UXM

UAI-4OC3MMF, UAI-4OC3SMF, UAI-2OC3SMF, UAI-8T1-IMA DB15, UAI-8E1-IMA DB15, UAI-8E1-IMA BNC

BXM-T3-8 or BXM-T3-12

BPX-T3/E3-8/12 (a universal back card for BXM-T3 or E3)

BXM-E3-8 or BXM-E3-12

BPX-T3/E3-8/12 (a universal back card for BXM-T3 or E3)

BXM-155-4

MMF-155-4, SMF-155-4, or SMFLR-155-4

BXM-155-8

MMF-155-8, SMF-155-8, or SMFLR-155-8

BXM-622

SMF-622 or SMFLR-622

BXM-622-2

SMF-622-2 or SMFLR-622-2

Setting Up an ATM Connection

To set up an ATM connection, perform the following steps:


Step 1   Activate a line with the upln command. Activating a line makes it available so you can configure it. Also, it starts statistics collection. Subsequently, you can begin to add connections with addcon. You can verify that the line has been activated by using the dsplns command. (See the chapter titled "Setting Up Lines" for descriptions of upln and dsplns.)

Step 2   Activate the ATM port with the upport X.X command, where X.X is the slot and port of the ATM card set.

Step 3   Use the cnfport command to establish the characteristics for the ATM port.

Step 4   If a suitable class is already configured, note its number and use this class when adding the ATM connection with the addcon command. (The dspcls command displays the parameters for each connection class. The cnfcls command allows you to modify an individual class.)

Step 5   Use the vt command to log in to the node at the remote end of the proposed ATM connection.

Step 6   At the remote node, use the upln, upport, and cnfport commands, as listed in steps 1 and 2, to activate and configure the remote port.

Step 7   Use the addcon command at one end of the connection to activate the ATM connection.


Managing Bandwidth

There are several commands that assist you in managing bandwidth to achieve satisfactory traffic patterns.

  • cnfpref

Use the configure preference command to specify preferred routing for intra-domain connections. You can use this command to assist in balancing the load on the network's trunks.

  • dsprts, prtrts

Use the display and print routes commands in conjunction with the cnfpref command to display the current connection routing information.

  • upcon, dncon

Use the up and down connection commands to temporarily down connections, thus releasing bandwidth for other services. Frequently, to provide more bandwidth for data, Frame Relay, or ATM traffic, you can down some voice connections.

Other Commands

The following commands are useful in establishing connections.

  • delcon

Deletes a connection from an ATM line.

  • dspcons

Displays the connections on a specified ATM line.

  • dsplnutl

Displays the line utilization for an ATM line.

Summary of Commands

Table 9-2 shows the name of each ATM connection command and the page the command description starts on.


Table 9-2:
ATM Connection Commands
Mnemonic Description Page

addcon

Add connection

9-5

clrchstats

Clear channel statistics

9-19

cnfabrparm

Configure ABR parameters (applies to BXM)

* See below

cnfatmcls

Configure ATM class

9-21

cnfcdparm

Configure channel statistic level on UXM/BXM cards

*See below.

cnfcls

Configure class

9-24

cnfcon

Configure connection

9-27

cnfport

Configure port

9-29

cnfportq

Configure port queue

9-37

delcon

Delete connection

9-41

dnport

Down port

9-43

dspatmcls

Display ATM class

9-45

dspchstats

Display channel statistics

9-48

dspcls

Display class

9-54

dspcon

Display connection

9-57

dspconcnf

Display connection configuration

9-63

dspcons

Display connections

9-66

dsplmistats

Display LMI statistics

9-73

dspport

Display port

9-77

dspportq

Display port queue

9-80

dspportstats

Display port statistics

9-83

upport

Up port

9-88

*Refer to the Cisco WAN Switching SuperUser Command Reference.

addcon

Establishes an ATM connection between the current node and one or more nodes in the network. You can add ATM connections at a UNI port on either an ASI or a BXM in a BPX node, or an ALM/A or a UXM in an IGX node. When used with the syntax in this chapter, addcon adds either a standard ATM connection or an ATM-Frame Relay interworking connection. You can also use addcon to add a virtual path connection (or VP tunnelling DAX connection) between a line port on an IGX-UXM as the VP side, and the line port at the ATM cloud entry point as the VCC side. For a description of the addcon command as it applies to Frame Relay connections, voice connections, or serial data connections, refer to the chapter in this manual that describes the applicable traffic type. For descriptions of the ATM commands that operate on an MGX 8220 shelf, see the MGX 8220 documentation. For descriptions of the ATM commands that operate on an MGX 8850 shelf, see the MGX 8850 documentation.

Note that in this release, on BXM and UXM cards, you can configure port and trunk (routing and feeder trunk) interfaces on the same card slot. For example, you can have port 1 on a BXM slot upped as a trunk interface while having port 2 on the same card slot upped as a line interface. For more information on the Port and Trunks feature, refer to the "Setting Up Trunks" chapter.

In Release 9.2.10, you can add VP tunnelling DAX connections. This type of connection has a VP connection as one end of the connection, and the other end as a VC connection. This VP tunnelling DAX connection can be between different port interfaces on the same UXM card, or on different UXM cards. See Example 2.

In Release 9.2.20, you can add both rt-VBR and nrt-VBR connections. The parameter prompts are the same for both rt-VBR and nrt-VBR, except for Trunk Cell Routing Restrict, which displays for all ATM connections except real-time VBR connections. (This is because rt-VBR connections should only be routed over ATM trunks such as BXM, UXM, and ASI trunks; rt-VBR connections should not be routed over FastPacket trunks such as BTM or ALM/B trunks.)


Note   In Release 9.2.20, the rt-VBR class of service is supported on the IGX UXM and BPX BXM, ASI, and BNI cards only. It is not supported for BTM or ALM-A/B connection endpoints. The rt-VBR class of service is not supported on FastPacket trunks, nor is it supported on MGX 8850 or MGX 8220 (AXIS) interface shelves.

Note that for segment connections, all 2- and 3-segment connections must be the same, that is, all rt-VBR or all nrt-VBR. The CLI will not block you from adding any combination of rt-VBR or nrt-VBR segment connections.

The CLI will block you from adding rt-VBR connections in a network of nodes running releases previous to Release 9.2. All nodes in the network must be first upgraded to Release 9.2.10. In a mixed network of Release 9.1 and 9.2.20, or Release 9.2.10 and 9.2.20, the rt-VBR class of service is not supported—in this scenario, all VBR connections will function as nrt-VBR connections. To support rt-VBR, all nodes in the network must be running switch software 9.2.20. See the Cisco WAN Switching 9.2 Release Notes for more information.

In Release 9.2.0, the switch software supports a minimum Peak Cell Rate (PCR) of 6 cps without policing enabled on both the BXM and UXM. In Release 9.3.0, the switch software supports a minimum PCR of 6 cps with policing enabled (with certain card limitations). Use the dspcd command to determine if this feature is supported on a given slot. Use the addcon command to set the minimum PCR values. If these values are less than the minimum values supported on a given card, the command line interface will not allow you to set them until you have disabled policing. (A prompt will let you know about this limitation, and allow you to disable policing.) Note the following when adding a card:

    1. If this new feature is enabled on a card, but is replaced by a card with older firmware (not supporting this feature) the dspcd screen parameter "card status" will display "Mismatch," and indicate the reason for the mismatch.

    2. If two cards are loaded with new firmware supporting this feature and configured for Y-redundancy, and one replaced with a card with old firmware, the result is a "mismatch."

For ABRSTD, a policing prompt is now added for VSVD=OFF connections.

Please refer to Table 9-5 for a list of cards that are supported by this feature and their performance specifications.

The addcon command for ATM adds any one of the following types of ATM connections:

Detailed connection sequences can be found in the Cisco BPX Series Installation and Configuration. This description has the following information:

For detailed descriptions of the connection types, traffic classes, policing, and ATM-related topics, refer to the Cisco BPX 8600 Series Installation and Configuration guide or the ATM Forum specifications.

The node on which addcon executes is the "owner" of the connection. Connection ownership is important because automatic rerouting and preferred routing information is entered on the node that owns the connection. See the cnfpref and cnfcos descriptions for details on automatic rerouting.

The parameter prompts depend on the connection type. The figures on this and the following pages are flow diagrams showing the sequence of possible parameter prompts according to the connection type. The flow diagrams begin at the point after you have entered the remote node name and VPI and VCI (which are common parameters). The subsequent tables define the parameters and list the defaults and ranges for each parameter.

A form of notation appears for some parameters that may need explanation. The notation is either (0), (1), or (0+1). This refers to the state of the Cell Loss Priority (CLP) bit. The usage of the CLP bit is in the traffic policing schemes. (0+1) means cells with CLP=0 or 1. (0) means cells with CLP=0. (1) means cells with CLP=1. The CLP bit is used in different contexts. For example, CDVT (0+1) refers to Cell Delay Variation Tolerance (CDVT) for cells with CLP=0 or 1.

Before a connection is added, the proposed connection appears on the screen prompting you to confirm. After addcon executes, the system software automatically routes the connection.

Instead of entering a class of service, the user can instead enter a class number to select a pre-configured template, for example, class 4 for NTR-VBR, and class 3 for RT-VBR. The class of service templates can be modified as required using the cnfcls/cnfatmcls command and displayed using the dspcls/dspatmcls command.


Note   An IGX switch running NPM-64/4M BRAM, now has increased VC Bandwidth Parameter entries. This provides support for more connections with different bandwidths. When adding or modifying a connection, the input bandwidth parameters are checked against the existing VC Bandwidth Parameters array. If there is a match against an existing parameter in the array, then that particular parameter entry will be used for the connection issued. If there is no match, a new VC Bandwidth Parameter is assigned to the connection. The maximum number of VC Bandwidth Parameters for the NPM-64/4M BRAM was 700. With Release 9.3.0 switch software and higher, the maximum number is 1999.


Note   For a new node running 9.2.20 or later, the rt-VBR connection class number is 3. An upgraded node will retain existing connection classes. Therefore, it won't have the rt-VBR connection class 3. However, the user can configure the connection classes to whatever service and parameters they want using the cnfcls/cnfatmcls command.

Network and Service Interworking

Frame Relay to ATM Interworking enables Frame Relay traffic to be connected across high-speed ATM trunks using ATM standard Network and Service Interworking.

Two types of Frame Relay to ATM interworking are supported, Network Interworking and Service Interworking. The Network Interworking function is performed by the BTM card on the IGX switch. The FRSM card on the MGX 8220 supports both Network and Service Interworking.


Figure 9-1: Prompt Sequence for a CBR Connection



Table 9-3:
addcon—Parameters
Parameter/Prompt Description

local channel

Specifies the local slot, port, virtual path identifier (vpi), and virtual connection identifier (vci) for the connection. The format is slot.port.vpi.vci.

The VPI range for a UNI connection is 1-255. The VPI range for an NNI connection is 1-4095.

When adding an MGX 8850 interface shelf with a UNI interface to a BPX routing node, the VPI range is 1-255. The VCI range is 1-65535.

When adding an MGX 8850 interface shelf with an NNI interface to a BPX routing node, the VPI range is 1-255. The VCI range is 1-65535.

When adding an SES (Service Expansion Shelf) to an IGX 8400 routing node, for VCC addressing, the VPI range is 1-255. The VCI range is 1-65535.

For VPC addressing, when adding an SES interface shelf to an IGX 8400 routing hub with a UNI interface, the VPI range is 1-255. The VCI range is 1-65535.

For VPC addressing, when adding an SES shelf to an IGX 8400 routing with an NNI interface, the VPI range is 1-4095. The VCI range is 1-65535.

Note   When adding an SES to an IGX 8400 routing node, the VPI/VCI configured on the IGX 8400 routing hub should match the VPI/VCI configured on the SES interface shelf endpoint address.

When adding a VP tunnelling DAX connection to an IGX-UXM card, either end of the connection can be the VPI or VCI side. This connection type can be any of the ATM connection types supported by UXM virtual trunks, for example, ABR, CBR, UBR, and VBR.

The VCI range is 1-65535. The vci can be an asterisk (*) to indicate the connection is a virtual path connection (so the vci has no meaning within the network).

remote node name

Specifies the name of the node at the other (or remote) end of the connection.

remote channel

Specifies the remote node's slot, port, vpi, and vci for this connection. The format is slot.port.vpi.vci. The vpi and vci ranges are:

The vpi range for a UNI connection is 1-255. The vpi range for an NNI connection is 1-4095.

The range for a vci is 1-65535. The vci can be an asterisk (*) to indicate the connection is a virtual path (the vci does not provide a distinction within the network).

connection class/
traffic type

Specifies one of the following traffic types—VBR (rt-VBR or nrt-VBR), UBR, CBR, ATFST, ATFR, ABRSTD, ABRFST, ATFT, ATFX, ATFTFST, or ATFXFST; or connection classes—for example, for rt-VBR, connection class 3 for a new node running Release 9.2.20.

The subsequent displayed parameters depend on the connection type you choose. To see the parameters associated with each connection type, refer to the appropriate flow diagrams in the refer to the Cisco BPX Series Installation and Configuration.

The option for choosing a class number is also available. The class is a template for a connection type. The class serves as an alternative to specifying each parameter for a connection type. To specify a connection class, enter a digit in the range 1-10. To see the parameter values for a class, use the dspcls commands. To customize any class template, use cnfcls.

For a new node running 9.2.20 or later, the rt-VBR connection class number is 3. An upgraded node will retain existing connection classes. Therefore, it won't have the rt-VBR connection class 3. However, you can configure the connection classes to whatever service and parameters you want by using the cnfcls/cnfatmcls command.

Note   For VP tunnelling DAX connections, a VP tunnelling connection type is represented by CBRVP, ABRSTVP, ABRFSTVP, etc. (The letters "VP" are appended to the connection class or connection type, to indicate that it is a VP tunnelling connection.) This connection type must be the same as the VCC connection type provisioned within the public ATM cloud.

PCR

Peak Cell Rate: the cell rate that the source cannot exceed.

%Util

Specifies the percentage of bandwidth utilization.

MCR

Minimum Cell Rate: the committed, minimum cell rate for a connection in a network.

CDVT

Cell Delay Variation Tolerance: controls time scale over which the PCR is policed.

FBTC (AAL5 Frame-based Traffic Control)

To enable the possibility of discarding the whole frame, not just one non-compliant cell. This is used to set the Early Packet Discard bit at every node along a connection.

With the ASI, FBTC means packet discard on both policing and queueing. With the BXM, FBTC means packet discard on queueing only.

VSVD

Virtual Source Virtual Destination.

Flow Control External Segments

Enables Cisco WAN switches to perform flow control on external segments (on the CPE, for example) in addition to the Cisco WAN Switching segments.

SCR

Sustainable Cell Rate: the long-term limit on the rate that a connection can sustain.

MBS

Maximum Burst Size: the maximum number of cells that can burst at the PCR and still be compliant. MBS is used to determine the Burst Tolerance (BT), which controls the time period over which the SCR is policed.

Policing

(see Table 9-5)

With the ASI, FBTC means packet discard on both policing and queueing. With the BXM, FBTC means packet discard on queueing only.

VC QDepth

The depth of the queue VC QDepth.

CLP Hi

Cell Loss Priority Hi threshold (% of VC QDepth). When the high threshold is exceeded, the node discards cells with CLP=1 until the number of cells in the queue drops below the level specified by CLP Lo/EPD.

CLP Lo/EPD

Cell Loss Priority Low threshold (% of VC QDepth)/Early Packet Discard. When the number of cells in the queue drops below the level specified by CLP Lo/EPD, the node stops discarding cells with CLP=1.

If the card is a BXM and AAL5 FBTC=yes, the percent of VC QMax equals the value of EPD. Frame-based Traffic Control (FBTC) is FGCRA for AAL5.

The BXM does not support Frame-based Policing.

For an ASI card, the percent of VC QMax is CLP Lo regardless of the FBTC setting.

EFCI

Explicit Forward Congestion Indication threshold (% of VC QDepth).

ICR

Initial Cell Rate: the rate at which a source initially transmits after an idle period.

IBR

Initial Burst Size: the maximum burst size a source can initially transmit after an idle period. IBR applies to only BXM cards.

ADTF (ATM Forum TM 4.0 term)

The Allowed-Cell-Rate Decrease Factor.

Time permitted between sending RM-cells before the rate is decreased to ICR. (In previous software releases, ADTF was ICR TO—Initial Cell Rate Time Out.)

Trm (ATM Forum TM 4.0 term)

An upper bound on the time between forward RM-cells for an active source: an RM cell must be sent at least every Trm milliseconds. (In previous software releases, Trm was Min. Adjust.)

RIF (ATM Forum TM 4.0 term)

Rate Increase Factor: controls the amount by which the cell transmission rate may increase upon receipt of an RM cell. (In previous software releases, RIF was Rate Up.)

RDF (ATM Forum TM 4.0 term)

Rate Decrease Factor: controls the amount decrease in cell transmission rate when an RM cell arrives. (In previous software releases, RDF was Rate Down.)

Nrm (ATM Forum TM 4.0 term)

Nrm.

Maximum number of cells a source may send for each forward RM cell: an RM cell must be sent for every Nrm-1 data cells.

FRTT (ATM Forum TM 4.0 term)

Fixed Round Trip Time: the sum of the fixed and propagation delays from the source to a destination and back.

TBE (ATM Forum TM 4.0 term)

Transient Buffer Exposure

The negotiated number of cells that the network would like to limit the source to sending during start-up periods, before the first RM-cell returns.

PCR

Peak cell rate: the cell rate which the source may never exceed.


Table 9-4:
addcon—Parameter Defaults and Ranges
Parameter with (Default Settings) UXM and BXM T1/E1, T3/E3, OC-3, and OC-12 Range ASI Range

PCR(0+1)[50/50]

50-max. T1/E1 cells/sec.

50-max. T3/E3 cells/sec.

50-max. OC-3 cells/sec

50-max. OC-12 cells/sec

T3: MCR-96000

E3: MCR-80000

OC-3 (STM1): 0-353200

Limited to MCR-5333 cells/sec for ATFR connections.

%Util [100/100]

for UBR [1/1]

0-100%

1-100%

MCR [50/50]

cells/sec

6-max. of T3/E3/OC-3/OC-12

T3: 0-96000 cells/sec

E3: 0-80000 cells/sec

AAL5 Frame-Based Traffic Control:

for rt/nrt-VBR [disable]

for ABR/UBR [enable]

for Path connection [disable]

enable/disable

With the BXM card, FBTC means packet discard on both policing and queueing.

enable/disable

With the ASI card, FBTC means packet discard on both policing and queueing.

CDVT(0+1):

for CBR [10000/10000],

others [250000/250000]

0-5,000,000 microsecs.

T3/E3 1-250,000 usecs.

OC-3/STM1: 0-10000 usecs.

ForeSight [disable]

0 = disable

1 = enable

0 = disable

1 = enable

VSVD [disable]

enable/disable

enable/disable

Flow Control External Segment [disable]

enable/disable

enable/disable

Default Extended Parameters [enable]

enable/disable

enable/disable

CLP Setting [enable]

enable/disable

enable/disable

SCR [50/50]

c50-max. T1/E1 cells/sec.

50-max. T3/E3 cells/sec.

50-max. OC-3 cells/sec

50-max. OC-12 cells/sec

T3: MCR-96000:T3

E3: MCR-80000: E3

OC-3/STM1: 0-353200

Limited to MCR-5333 cells/sec for ATFR connections.

MBS [1000/1000]

1--5,000,000 cells

T3/E3: 1-24000 cells

OC-3 (STM1): 10-1000 cells

Policing [3]

For CBR: [4]

1 = VBR.1

2 = VBR.2

3 = VBR.3

4 = PCR policing only

5 = off

1 = VBR.1

2 = VBR.2

3 = VBR.3

4 = PCR policing only

5 = off

ICR:

max [MCR, PCR/10]

MCR - PCR cells/sec

MCR - PCR cells/sec

ADTF [1000]

62-8000 msecs.

1000-255000 msecs.

Trm [100]

ABRSTD: 1-100 msecs.
ABRFST: 3-255 msecs.

20-250 msecs.

VC QDepth [16000/16000]

For ATFR/ATFST [1366/1366]

0-61440 cells

Applies to T3/E3 only
ABR: 1-64000 cells
ATFR: 1-1366 cells

CLP Hi [80/80]

1-100%

1-100%

CLP Lo/EPD [35/35]

1-100%

1-100%

EFCI [30/30]

For ATFR/ATFST [100/100]

1-100%

1-100%

RIF:

For ForeSight: =

max [PCR/128, 10]

For ABRSTD [128]

If ForeSight, then in absolute (0-PCR)

If ABR, then 2n

(1-32768)

If ForeSight, then in absolute (0-PCR)

If ABR, then 2n

(1-32768)

RDF:

For ForeSight [93]

For ABRSTD [16]

IF ForeSight, then %

(0%-100%)

If ABR, then 2n

(1-32768)

IF ForeSight, then %

(0%-100%)

If ABR, then 2n

(1-32768)

Nrm[32]-BXM only

2-256 cells

not applicable

FRTT[0]-BXM only

0-16700 msec

not applicable

TBE[1,048,320]-BXM only

0-1,048,320 cells

(different maximum range from TM spec. but limited by firmware for CRM (4095 only) where CRM=TBE/Nrm

not applicable

IBS [0/0]

0-24000 cells

T3/E3 ABR: 0-24000 cells ATFR: 1-107 cells

OC-3: 0-999 cells

Trunk Cell Routing Restriction (y/n) [y]

yes or no

For rt-VBR connections, this prompt will not display. (This is because rt-VBR connections should only be routed over ATM trunks such as BXM, UXM, and ASI, not over FastPacket trunks such as BTM or ALM/A-B.) Trunk Cell Routing Restriction will display for all other connections.

yes or no

For rt-VBR connections, this prompt will not display. (This is because rt-VBR connections should only be routed over ATM trunks such as BXM, UXM, and ASI, not over FastPacket trunks such as BTM or ALM/A-B.) Trunk Cell Routing Restriction will display for all other connections.


Table 9-5: Minimum PCR Values with Policing Enabled
Card Name Card Types Minimum PCR Values with Policing

IGX-UXM

T1/E1

6 cps

IGX-UXM

IMA

6 cps

IGX-IUX

T3/E3

12 cps

IGX-UXM

OC3/STM-1

50 cps

BPX-BXM

T3/E3

12 cps

BPX-BXM

OC3/STM-1

50 cps

BPX-BXM

OC12/STM-4

50 cps

Note: The policing accuracy is always within 1%. The maximum PCR policing values are the same as the line rate.


Table 9-6: Traffic Policing Definitions
Connection Type ATM Forum TM Spec. 4.0 Conformance Definition PCR Flow (1st Leaky Bucket) CLP Tagging (for PCR Flow) SCR Flow (2nd Leaky Bucket) CLP Tagging (for SCR Flow)

CBR

CBR.1

when policing set to 4 (PCR policing only)

CLP(0+1)

no

off

n/a

CBR

when policing set to 5 (off)

off

n/a

off

n/a

UBR

UBR.1

when CLP setting = no

CLP(0+1)

no

off

n/a

UBR

UBR.2

when CLP setting = yes

CLP(0+1)

no

CLP(0)

yes

rt/nrt-VBR, ABR, ATFR, ATFST

VBR.1

when policing set to 1

CLP(0+1)

no

CLP(0+1)

no

rt/nrt-VBR, ABR, ATFR, ATFST

VBR.2

when policing set to 2

CLP(0+1)

no

CLP(0)

no

rt/nrt-VBR, ABR, ATFR, ATFST

VBR.3

when policing set to 3

CLP(0+1)

no

CLP(0)

yes

rt/nrt-VBR, ABR, ATFR, ATFST

when policing set to 4

CLP(0+1)

no

off

n/a

rt/nrt-VBR, ABR, ATFR, ATFST

when policing set to 5 (off)

off

n/a

off

n/a

Note   For UBR.2, SCR = 0

Note   CLP = Cell Lost Priority
CLP(0) means cells that have CLP = 0
CLP(1) means cells that have CLP = 1
CLP(0+1) means both types of cells: CLP = 0 & CLP = 1
CLP(0) has higher priority than CLP(1)
CLP tagging means to change CLP = 0 to CLP = 1, where CLP= 1 cells have lower priority


Table 9-7:
VBR Policing Definitions
Connection Type ATM Forum TM Spec. 4.0 Conformance Definition PCR Flow (1st Leaky Bucket) CLP Tagging (for PCR Flow) SCR Flow (2nd Leaky Bucket) CLP Tagging (for SCR Flow)

rt/nrt-VBR, ABR, ATFR, ATFST, ATFT, ATFTST, ATFX, ATFXFST

VBR.1

when policing set to 1

CLP(0+1)

no

CLP(0+1)

no

rt/nrt-VBR, ABR, ATFR, ATFST, ATFT, ATFTST, ATFX, ATFXFST

VBR.2

when policing set to 2

CLP(0+1)

no

CLP(0)

no

rt/nrt-VBR, ABR, ATFR, ATFST, ATFT, ATFTST, ATFX, ATFXFST

VBR.3

when policing set to 3

CLP(0+1)

no

CLP(0)

yes

rt/nrt-VBR, ABR, ATFR, ATFST, ATFT, ATFTST, ATFX, ATFXFST

when policing set to 4

CLP(0+1)

no

off

n/a

rt/nrt-VBR, ABR, ATFR, ATFS, ATFT, ATFTST, ATFX, ATFXFST

when policing set to 5 for off

off

n/a

off

n/a

Full Name

Add a connection

addcon parameters (see preceding tables)

Related Commands

delcon, dspcons

Attributes

Privilege Jobs Log Node Lock

1-2

Yes

Yes

IGX, BPX

Yes

Example 1

addcon 9.1.100.100 pubsbpx2 9.1.102.102

Description

Add a standard ABR connection with VSVD and no Default Extended Parameters (which then require user input for SCR, MBS, and so on).

System Response
pubsbpx1 TN SuperUser BPX 15 9.2 Oct. 27 1997 05:22 GMT From Remote Remote Route 9.1.100.100 NodeName Channel State Type Avoid COS O 9.1.100.100 pubsbpx2 9.1.102.102 Ok abrstd 9.1.102.102 pubsbpx2 9.1.100.100 Ok abrstd This Command: addcon 9.1.100.100 pubsbpx2 9.1.102.102 abr * * * * e e * d * * 1 * * * * * * * * * Add these connections (y/n)?
Example 2

addcon 5.2.10.* pubsigx1p 5.1.1.100 CBR ...

Description

Add a virtual path connection (VPC) to virtual circuit connection (VCC) between ports 1 and 2. (This is called a VP tunnelling connection.)

System Response
pubsigx1 TN SuperUser IGX 8400 9.2 Oct. 27 1998 05:22 GMT From Remote Remote Route NodeName Channel State Type Avoid COS O 5.2.10.* pubsigx2 5.1.1.100 Ok abrstvp 5.1.1.100 pubsigx2 5.2.10.* s Ok abrstvp This Command: addcon 5.2.10.* pubsigx1p 5.1.1.100 CBR ... Add these connections (y/n)?

clrchstats

Clears the gathered statistics for either a specific channel or all channels. When you enter a specific channel number, the current channel statistics display appears, asking if you want to clear the display. If you enter "*" (all channels) for the channel specification, the display prompts you to confirm whether you want to clear all channel statistics. This is sometimes referred to as a summary statistics command.

The Multilevel Channel Statistics lets you configure and display additional levels of statistics beyond level 1 statistics (for example, levels 2 and 3), as supported by the multilevel channels statistics feature. You use the cnfcdparm command to configure the channels statistics level on the BXM or UXM cards. For example, if you configure slot 5 to support level 3 channel statistics, all connections on that particular card are set to provide level 3 statistics. Switch software collects, displays, and propagates to Cisco WAN Manager the various statistics types. The channel statistic type vary in number and type based on the level of support provided by the BXM and UXM cards. You use the dspchstats and clrchstats to display and clear the statistics.

Full Name

Clear channel statistics

Syntax

clrchstats <channel | *>

Related Commands

dspchstats

Attributes

Privilege Jobs Log Node Lock

1-2

Yes

Yes

IGX, BPX

Yes

Example 1

clrchstats 3.1.1

Description

Clear channel statistics for 3.1.1.

System Response
sw83 TN SuperUser IGX 8420 9.2 Aug. 23 1997 19:24 PST Channel Statistics: 3.1.1 Cleared: Aug. 17 1997 08:10 MIR: 3.8 kbps Collection Time: 6 day(s) 10:04:58 Corrupted: NO Frames Avg Size Avg Util Packets Avg (bytes) (fps) (%) (pps) From Port: 1516586 198 2 35 To Network: 1516215 198 2 35 16678365 30 Discarded: 371 198 0 0 From Network: 1518665 197 2 35 16705146 30 To Port: 1518629 198 2 35 Discarded: 36 120 0 0 238 0 ECN Stats: Avg Rx VC Q: 0 ForeSight RTD 40 Min-Pk bytes rcvd: 52470 FECN Frames: 0 FECN Ratio (%) 0 Minutes Congested: 0 BECN Frames: 16 BECN Ratio (%) 0 Frames rcvd in excess of CIR: 0 Bytes rcvd in excess of CIR: 0 Frames xmtd in excess of CIR: 0 Bytes xmtd in excess of CIR: 0 This Command: clrchstats 3.1.1 OK to clear (y/n)?


Table 9-8: clrchstats—Parameters
Parameter Description

channel

Specifies the channel whose statistics are cleared.

*

Specifies all channel statistics.

cnfatmcls

The cnfatmcls command allows the ten Cisco-supplied class templates for ATM connection configuration to be modified. (The addcon command can take a class as an input.)

When you enter the number of the class to configure, the display shows the current value of each parameter in the class. For each item in the class, a prompt appears for changing or keeping the current value.

In Release 9.2.20, you can use cnfatmcls and cnfcls to configure the rt-VBR ATM connection class. You can use dspatmcls and dspcls to display the connection parameters for the rt-VBR and nrt-VBR connection classes.

The rt-VBR connections are configured per class 3 service parameters, and nrt-VBR connections are configured per class 2 service parameters. You can change these class parameters by using the cnfcls/cnfatmcls command, or you can enter the parameters individually for each connection by specifying yes to the extended parameters prompt of the addcon command.


Note   For a new node running software Release 9.2.20 or later, the rt-VBR connection class number is 3. An upgraded node will retain existing connection classes. Therefore, it won't have the rt-VBR connection class 3. However, the user can configure the connection classes to whatever service and parameters they want using the cnfcls/cnfatmcls command. For nrt-VBR connections in a new node, running 9.2.20, a number of connection classes are pre-configured, including 2, 4, 5, and 6.

Full Name

Configure class

Syntax

cnfatmcls <class number> [optional parameters]

Related Commands

addcon, cnfatmcls, dspatmcls, cnfcls, dspcls

Attributes

Privilege Jobs Log Node Lock

1-2

Yes

Yes

IGX, BPX

Yes

Example 1

cnfatmcls 10

Description

Configure ATM connection class 10. The command line interface (CLI) displays the current settings and requests the class type (see System Response 1). After you enter a class type, the CLI prompts you to specify each parameter for the selected class type (ABRSTD as System Response 2 shows).

System Response 1
sw60 TN SuperUser BPX 8620 9.2 Date/Time Not Set ATM Connection Classes Class: 10 Type: CBR PCR(0+1) % Util CDVT(0+1) Policing 4000/4000 100/100 10000/10000 4 Description: "Default CBR 4000" This Command: cnfatmcls 10 Enter class type (rt-VBR, nrt-VBR, UBR, CBR, ATFST, ATFR, ABRSTD, ABRFST, ATFT, ATFX, ATFTFST, ATFXFST):
System Response 2
sw60 TN SuperUser BPX 8620 9.2 Date/Time Not Set ATM Connection Classes Class: 10 Type: ABRSTD PCR(0+1) % Util MCR CDVT(0+1) AAL5 FBTC 4000/4000 100/100 4000/4000 10000/10000 n Description: "Default CBR 4000" This Command: cnfatmcls 10 abrstd * * * * * Do you want this change (y/n)?
Example 2

cnfatmcls 3

Description

Configure ATM connection class 3 for rt-VBR class type connection parameters. The command line interface (CLI) displays the current settings and requests the class type.

System Response 3
sw60 TN SuperUser BPX 8620 9.2 Date/Time Not Set ATM Connection Classes Class: 3 Type: rt-VBR PCR(0+1) % Util CDVT(0+1) AAL5 FBTC SCR 2000/2000 100/100 10000/10000 n 2000/2000 MBS Policing 1000/1000 3 Description: "Default rt-VBR 2000" This Command: cnfatmcls 3 Enter class type (rt-VBR, nrt-VBR, UBR, CBR, ATFST, ATFR, ABRSTD, ABRFST, ATFT, ATFX, ATFTFST, ATFXFST):


Table 9-9: cnfatmcls-Parameters
Parameter Description

class

Specifies the class to configure. The class numbers are 1-10.


Table 9-10: cnfatmcls-Optional Parameters
Parameter Description

optional parameters

Individual parameters are specific to the type of connection (rt-VBR, nrt-VBR, CBR, UBR, ATFST, ATFR, ABRSTD, ABRFST, ATFT, ATFX, ATFTFST, ATFXFST). Each is prompted one at a time. Refer to the dspcls command to see the parameters in each of the classes.

cnfcls

The cnfcls command allows the ten Cisco-supplied class templates for connection configuration to be modified. (The addcon command can take a class as an input.)

When you enter the number of the class to configure, the display shows the current value of each parameter in the class. For each item in the class, a prompt appears for changing or keeping the current value.

In Release 9.2.20, you can use cnfatmcls and cnfcls to configure the rt-VBR ATM connection class. You can use dspatmcls and dspcls to display the connection parameters for the rt-VBR and nrt-VBR connection classes.

The rt-VBR connections are configured per class 3 service parameters, and nrt-VBR connections are configured per class 2 service parameters. These class parameters can be changed using the cnfcls/cnfatmcls command, or the parameters can be entered individually for each connection by specifying yes to the extended parameters prompt of the addcon command.


Note   For a new node running software Release 9.2.20 or later, the rt-VBR connection class number is 3. An upgraded node will retain existing connection classes. Therefore, it won't have the rt-VBR connection class 3. However, the user can configure the connection classes to whatever service and parameters they want using the cnfcls/cnfatmcls command. For nrt-VBR connections in a new node, running 9.2.20, a number of connection classes are pre-configured, including 2, 4, 5, and 6.

Full Name

Configure class

Syntax

cnfcls <class number> [optional parameters]

Related Commands

addcon, dspcls, cnfatmcls, dspatmcls

Attributes

Privilege Jobs Log Node Lock

1-2

Yes

Yes

IGX, BPX

Yes

Example 1

cnfcls 10

Description

Configure connection class 10. The command line interface (CLI) displays the current settings and requests the class type (see System Response 1). After you enter a class type, the CLI prompts you to specify each parameter for the selected class type (ABRSTD as System Response 2 shows).

System Response 1
sw60 TN SuperUser BPX 8620 9.2 Date/Time Not Set ATM Connection Classes Class: 10 Type: CBR PCR(0+1) % Util CDVT(0+1) Policing 4000/4000 100/100 10000/10000 4 Description: "Default CBR 4000" This Command: cnfcls 10 Enter class type (VBR, CBR, UBR, ABRSTD, ABRFST, ATFR):
System Response 2
sw60 TN SuperUser BPX 8620 9.2 Date/Time Not Set ATM Connection Classes Class: 10 Type: ABRSTD PCR(0+1) % Util MCR CDVT(0+1) AAL5 FBTC 4000/4000 100/100 4000/4000 10000/10000 n Description: "Default CBR 4000" This Command: cnfcls 10 abrstd * * * * * Do you want this change (y/n)?

An example of a cnfcls/cnfatmcls command and response is shown in the following example:

System Response 3
pubsbpx1 TN silves:1 BPX 8620 9.2.2G July 16 1999 10:42 PDT ATM Connection Classes Class: 2 Type: nrt-VBR PCR(0+1) % Util CDVT(0+1) AAL5 FBTC SCR 1000/1000 100/100 10000/10000 n 1000/1000 MBS Policing 1000/1000 3 Description: "Default nrt-VBR 1000 " This Command: cnfcls atm 2 Enter class type (rt-VBR, nrt-VBR, CBR, UBR, ABRSTD, ABRFST, ATFR, ATFST, ATFT, ATFTFST, ATFX, ATFXFST):


Table 9-11: cnfcls-Parameters
Parameter Description

class

Specifies the class to configure. The class numbers are 1-10.


Table 9-12: cnfcls-Optional Parameters
Parameter Description

optional parameters

Individual parameters are specific to the type of connection (CBR, rt-VBR, nrt-VBR, ABR, ATFR). Each is prompted one at a time. Refer to the dspcls command to see the parameters in each of the classes.

cnfcon

Configures the ATM bandwidth parameters for a specified connection. The initial cell rate (ICR) normally is set to the port speed. It may be lower if other constraints exist on the data-generation rate. If ICR is too low, cells are dropped. If it is too high, bandwidth may be wasted unless ForeSight is used. Statistical reports are the best source of information for deciding what to adjust.

If the connection type includes ForeSight (abr enabled), the results of the last test round-trip delay command (tstdelay) appear. Note that this is not the current RTD but the result of the last test that ran. Connection priority—high or low—is displayed for standard Frame Relay connections and ForeSight connections. Several checks are done on the parameters that specify bandwidth to assist users in efficient use of network bandwidth. The following messages describe the performance evaluation:

  • Error

Min cannot exceed peak.

  • Warning

Min exceeds this port's speed.

  • Warning

Sum of mins exceeds port's speed.

  • Warning

Peak exceeds this port's speed.

Warning messages are informational only, so the related operation continues. If an error message appears, the operation does not continue.

Full Name

Configure connection

Syntax

cnfcon <slot.port.vpi.vci> [bandwidth parameters]

Related Commands

addcon, dspcon

Attributes

Privilege Jobs Log Node Lock

1-2

Yes

Yes

IGX, BPX

Yes

Example 1

cnfcon 12.1.1.6

Description

Configure ASI port 12.1.1.6.

System Response
a20 LAN SuperUser BPX 15 9.2 Aug. 29 1997 11:43 PST Conn: 12.1.1.6 ca19 4.1.1.6 ABR Description: SCR IBS MBS ABR MCR PCR ICR 100/100 10/10 10/10 y 10/10 96000/96000 10/10 ICR TO Rate Up Rate Dn Rate FastDn Max Adjust VC Qdepth EFCI % Util 10 100 100 100 100 64000/64000 100/100 100/100 CLP CLP Hi CLP Lo y 100/100 90/90 This Command: cnfcon 12.1.1.6 MBS (10) must exceed IBS (10) Enter the MBS [10/10]:


Table 9-13: cnfcon—Parameters
Parameter Description

channel

Specifies the connection to configure. This command configures one connection at a time. The channel specification has the following format:

slot.port.vpi.vci


Table 9-14: cnfcon—Optional Parameters
Parameter Description

bandwidth parameters

Refer to the addcon command in this chapter for descriptions and connection types.

cnfport

Configures the parameters of an ATM port on an ASI or BXM card on the BPX or a UXM card on the IGX. Press Return to keep the current value of a parameter. See the parameter table for important information.

Previous to Release 9.2, on the BXM card, only ABR VSVD connections are subject to VC scheduling policies on the egress and that is only when the FCES (external segment) option is enabled. With the introduction of traffic shaping, you can choose whether to perform VC scheduling on CBR, VBR, and UBR traffic streams.

In this release, the Ports and Trunks feature lets you configure multiple trunk lines and circuit lines on a single BXM or UXM card simultaneously. In previous releases, when you upped a single port as a trunk (by using the uptrk command), all the remaining ports on that card were treated as a trunk. Similarly, when you up a single port as a circuit line (by using the upln command), all the remaining ports on the card are treated as circuit line ports. This feature allows BXM and UXM cards to be trunk line cards as well as circuit line cards at the same time. This allows trunks as well as circuit lines to coexist on these interface cards.

Feature Mismatching to Verify LMI/ILMI Support

The cnfport commands, in addition to other configuration commands, perform mismatch verification on the BXM and UXM cards. For example, the cnfport command will verify whether the cards both have LMI/ILMI configured.

The command cnfport will prevent disabling ILMI protocol on a port interface if a VSI ILMI session is active on a VSI partition of the port interface. Configure ILMI protocol running on a port interface to run on the BCC instead of the BXM.

Refer to "Feature Mismatching" in the BPX 8600 Series Installation and Configuration. The Feature Mismatching capability will not mismatch cards unless the actual feature has been enabled on the card. This allows for a graceful card migration from an older release.

Traffic Shaping on the UXM Card in Release 9.2

Traffic shaping lets you choose whether to have VC scheduling performed to your CBR, VBR, and UBR traffic streams. You can configure the traffic shaping (which involves weighted fair queuing) option on each BXM interface. A cnfport parameter will prompt you to enable/disable traffic shaping. (The default is for traffic shaping to be disabled.)

Traffic shaping is performed on a per-port basis. When traffic shaping is enabled, all traffic exiting the port is subject to the VC scheduling based on the appropriate service parameters you provision. When a particular port is configured to perform traffic shaping, all ATM cells, regardless of class of service, pass through the VC queues before leaving the card. Where a port is not configured for traffic shaping, the CBR, VBR, and UBR PVCs circumvent the VC queues and are scheduled by the QBins.

No connections should exist on the port before changing the port traffic shaping parameter. If there are existing connections when the port traffic shaping parameter is toggled, then these connections will not be updated unless the card is reset, connections are rerouted, a switchcc occurs, or you modify the connection parameters. Also, traffic shaping is not enabled on a VSVC endpoint if an external segment has been enabled.

Redundant cards must both support traffic shaping, or neither support traffic shaping. In the non-redundant case, traffic shaping is configurable regardless of whether the BXM card in the target slot supports traffic shaping. If the card does not support traffic shaping, then a BXM card that does support traffic shaping can be inserted later and the traffic shaping configuration will take effect. System software will not perform mismatch checking on the traffic shaping capabilities of the BXM.

The traffic shaping rate parameters are in Table 9-15. The MCR is the minimum cell rate for the connection. This is the lowest rate that the connection will be scheduled from the VC queue into the QBin. The PCR is the peak cell rate, or the highest rate at which the connection will be scheduled from the VC queue into the QBin.


Table 9-15:
cnfport—Traffic Shaping Rates
Service Type MCR PCR

CBR

PCR

PCR

VBR

SCR1%Util

PCR

UBR

0

PCR

ABR

MCR %Util

PCR

1Indicates that the system software issues a warning that traffic shaping is not supported on that specific BXM.

Note that traffic shaping does not generate any alarms. There is no mismatch checking for BXMs that support traffic shaping, so if you insert a BXM card with firmware that does not support it, then the traffic shaping functionality will not exist.

Also, cells can be momentarily received out of order when you reconfigure connections between traffic shaping and non-traffic shaping. This is a limitation of the hardware for which there is no workaround.

Configuring Traffic Shaping

Traffic shaping involves passing ATM traffic through the ATM interface at a VC queue, scheduled rate. Currently, in the BXM-only ABR VSVD connections are subject to VC scheduling policies. With the introduction of traffic shaping, the customer will have the option to perform VC scheduling to his/her CBR, VBR, and UBR traffic streams. Traffic shaping is performed by the BXM hardware.

Traffic shaping will be performed on a per-port basis. When enabled, all traffic exiting the port will be subject to the VC scheduling based on the appropriate service parameters provisioned by the user. Note that all ATM cells, regardless of class of service, pass through the VC queues before leaving the card.

No connections should exist on the port before you change the port traffic shaping parameter. If there are existing connections when you toggle the port traffic shaping parameter, then these connections will not be updated unless you reset the card (by using the resetcd command), connections are rerouted, a switchcc occurs, or you modify the connection parameters. Also, it should be noted that traffic shaping is not enabled on a VSVD endpoint if external segment has been enabled.

Redundancy Architecture

Software requires that redundant cards either both support the feature or neither supports the feature. In the non-redundant case, the feature is configurable regardless of whether the BXM card in the target slot supports traffic shaping. If the card does not support the feature, then a BXM card that does support traffic shaping can be inserted later and the traffic shaping configuration will take effect. Switch software will not perform mismatch checking on the traffic-shaping capabilities of the BXM.

Cisco WAN Manager in Release 9.2 has no changes to support traffic shaping. Switch software functionality is limited to enabling the traffic shaping option (involving weighted fair queuing) on a per-BXM interface case. The cnfport command has a new parameter, which will prompt you to enable or disable traffic shaping. The parameter default is to disable the feature.

Refer to the WAN Switch Software Release 9.2 release notes for additional information on traffic shaping. No connections should be on the port before changing the port traffic shaping parameter. If there are existing connections when the port traffic shaping parameter is toggled, then these connections will not be updated unless the card is reset, connections are rerouted, a switchcc occurs, or you modify the connection parameters*. Also, it should be noted that traffic shaping is not enabled on a VSVD endpoint if an external segment has been enabled. In this case, the scheduling policies are based upon the ATMF 4.0 ABR rules.

The MCR is the minimum cell rate for the connection. This is the lowest rate that the connection will be scheduled from the VC queue into the Qbin. The PCR is the peak cell rate, or the highest rate at which the connection will be scheduled from the VC queue into the Qbin.

Firmware Functionality (BXM)

The BXM firmware supports a new Commbus parameter to enable/disable traffic shaping. When you add a connection, the BXM firmware checks its database to see if traffic shaping is enabled for the port that the connection is to be mapped to. If traffic shaping is enabled, the BXM firmware sets up the ASIC hardware to perform the weighted fair queuing. In the background, the BXM firmware runs a rate-based algorithm.

Existing functionality, such as VC queuing, is used by the traffic shaping feature.

In this release, the BXM firmware supports a new CommBus (CBUS) parameter to enable/disable traffic shaping. When a connection is added, the BXM firmware checks its database to see if traffic shaping is enabled for the port that the connection is to be mapped to. If traffic shaping is enabled, the BXM firmware sets up the ASIC hardware to perform the weighted fair queuing. In the background, the BXM firmware runs a rate-based algorithm similar to what is done today for ERS (explicit rate stamping). The only other interface change includes an egress SCR parameter in the channel (0x52) message.

The algorithm executed by the firmware involves the BXM firmware polling the cell arrival and transmit counters of the Qbins approximately every 15 msec. During this time, the firmware determines the congestion ratio:

where rp is the previous value of rc, "out" is the number of cells leaving the Qbin, and "in" is the number of cells arriving into the QBIN. Note that if the ratio of out/in is less than 1, then the Qbin is experiencing congestion. The BXM firmware takes the resulting "rc" and divides this value into the sum of all of the PCRs for the Qbin and uses this result as the congestion factor to be programmed into the hardware (SABRE).

Performance of Traffic Shaping

The weighted-fair queuing (WFQ) algorithm for traffic shaping runs the same algorithm as the explicit rate stamping (ERS). Today, this processing consumes 12 percent. Because the algorithm runs once (even if both ERS and WFQ are enabled), traffic shaping will not increase the worst-case demand for BXM processor time.

Errors and Alarm Handling

No alarms will be generated regarding the Traffic Shaping feature. As previously mentioned, there is no mismatch checking for BXMs that do not support the feature, so if you insert a BXM with firmware that does not support the feature, then the traffic shaping functionality will not be supported on that card.

It should be noted that cells can be momentarily received out of order when connections are reconfigured between traffic shaping and non-traffic shaping. This is a limitation of the hardware for which there is no work-around.

Full Name

Configure port

Syntax

cnfport <port> [<params>]

Related Commands

upport, dnport, dspport, dspports

Attributes

Privilege Jobs Log Node Lock

1-2

Yes

Yes

IGX, BPX

Yes

Example 1

cnfport 12.1 N N N H N N

Description

Configure port 12.1 to have a UNI cell header format; not to be an MGX 8220 shelf; not to have a Metro Cell Header format; shift on HCF; use no protocol; and not to apply %util.

System Response
batman TN SuperUser BPX 15 9.2 Date/Time Not Set Port: 12.1 Interface: T3-2 Type: UNI %Util Use: Disabled Speed: 96000 Shift: SHIFT ON HCF (Normal Operation) VBR Queue Depth: 1000 Protocol: NONE Last Command: cnfport 12.1 N N N H N N Next Command:
Example 2

cnfport 5.1 N N N N

Description

Configure port, when used with an IMA line, displays the IMA Port Group. It does not prompt for any new IMA configuration.

System Response
sw225 TRM StrataCom IGX 8420 9.3.a6 Mar. 10 2000 05:56 GMT Port: 5.1 [ACTIVE ] IMA Port Grp: 1-4 Interface: E1-IMA CAC Override: Enabled Type: UNI %Util Use: Disabled Speed: 17962 (cps) SIG Queue Depth: 640 Protocol: NONE This Command: cnfport 5.1 NNI Cell Header Format? [N]: Protocol [N]: Apply Percent Utilization? [N]: CAC Override Disable? [N]:


Table 9-16: cnfport—Parameters
Parameter Description

slot.port

Specifies the ASI, BXM, or UXM card slot and port number.

nni/uni

Specifies whether the cell header format is NNI or UNI. UNI is the default.

axis

Specifies MGX 8220 queue depth for each slot.

metro data cell header

Specifies whether the metro data cell header type is used.

shift h | n

Specifies whether a one-byte shift on the HCF field of the cell header occurs. The choice of H (shift) or N (no shift) depends on whether the ATM cloud includes non-Cisco WAN Switching nodes and whether virtual trunking is in operation:

  • You typically select H (the default, or shift on) if the cloud includes non-Cisco WAN Switching nodes or if only a physical trunk is configured for the ASI port.

  • You typically select N (shift off) if virtual trunks are configured and the ATM cloud consists of Cisco WAN Switching nodes only.

For BPX or IGX ports performing virtual trunking within an ATM cloud to external Cisco equipment, ports should be configured to shift on (that is, Shift H) for BNI cards; BXM ports should typically be configured to Shift off (Shift N).

Note   For UXM cards, you cannot configure the Shift parameter—the Shift setting is always N, or shift off.

For example, if the public ATM cloud consists of BPX nodes, the access points to the cloud might be ASI ATM-UNI ports. Because the cells transmitted to the ASI trunk interface are coming from a Cisco device, for example, a BNI card, the 16 VCI bits have already been left shifted by four (4) bits and contain 12 bits of VCI information and four (4) bits of ForeSight information. Therefore, the ASI cards at either end of the cloud should be configured to not shift (that is, Shift off). In this case, you would configure Shift N on the ASI port.

If the ATM cloud consists of non-Cisco nodes, then the 12 VCI + 4 bits ForeSight bits in the cells coming from the BNI card in the BPX are then passed through untouched as 16 VCI bits. Because it is a non-Cisco network, the ForeSight bits are ignored.

Make sure that you set the HCF field correctly for your network configuration before you add connections. For example, if you are acting as a service provider, and one of your customers wants to configure virtual trunking through the network, if your ports have been previously configured with the incorrect HCF shift field setting, you may need to go back and delete all the connections from each port, configure the port, and add the connections again.

Below shows some guidelines on how to set the Shift parameter when using BNI virtual trunking through a cloud of Cisco equipment using BXMs, and a cloud using ASIs and BNIs. Also shown is how to set the Shift parameter when using either BXM or UXM virtual trunking through a cloud of Cisco equipment (BXM cards), and a cloud of ASIs and BNIs.



protocol

Specifies the use of either an LMI protocol, an ILMI protocol, or no specified protocol. No specified protocol is the default. Values for protocol are one of the following:

N-(NONE)

L-(LMI)

I-(ILMI)

Note: An IMA configuration will display the same protocol values as shown above.

%util

Enables/disables percent utilization. This parameter supports ATM VBR/ABR fairness for ASI terminated connections and applies to only VBR and ABR connections. To change the %util status of a port, no connections can be currently terminating on the port. Therefore, if connections terminate on the port, they must be deleted before cnfport execution then re-added after execution of cnfport.

When this feature is disabled, the port queue bandwidth is calculated using the sum of the MCRs or PCRs for the connections terminating on the port. This is identical to the port queue bandwidth calculation prior to the implementation of the %util feature.

The port queue bandwidth with %util feature disabled is:

  • For ABR connections Port Queue BW = sum (MCR)

  • For VBR connections Port Queue BW = sum (PCR)

  • For CBR connections Port Queue BW = sum (PCR)

When the %util feature is enabled, the port queue bandwidth is calculated for ABR and VBR connections as follows: for ABR connections, the port queue bandwidth is the sum of a percentage of the MCRs for the connections terminating on the port; for VBR connections, the port queue bandwidth is the sum of a percentage of the PCRs for connections terminating on the port. The feature is not applied to CBR connections.

In summary, the port queue bandwidth with feature %util enabled is:

  • For ABR connections Port Queue BW = sum (MCR * %util)

  • For VBR connections Port Queue BW = sum (PCR * %util)

  • For CBR connections Port Queue BW = sum (PCR)

cnfportq

Configures queue parameters for a port on an ASI or BXM card on the BPX or a UXM card on the IGX. Pressing the Return key keeps the current value for the parameter.

In Release 9.2.20, the VBR class of service type can be either rt-VBR or nrt-VBR, depending on the way the corresponding port (service) queues (both ingress and egress) are configured. For the nrt-VBR class of service type in this release, the corresponding service queues are larger than in previous releases to provide more efficient bandwidth sharing with other non-real time service types. The service queues for both rt-VBR and nrt-VBR service types can be configured on a node-by-node basis.

You can use cnfportq to configure Qbin values separately for rt-VBR and nrt-VBR connection types on ports. (To configure the qbin values for rt-VBR and nrt-VBR classes of service on trunks, use cnftrkparm.) The rt-VBR and nrt-VBR connections use different queues on a port: these are the rt-VBR and nrt-VBR queues, respectively. (See Example 3 for a cnfportq screen showing the configuration parameters available for a port queue.)

For information on configuring trunk queues used by rt-VBR and nrt-VBR connections, see the cnftrkparm command.

Configuring Port Queues used by rt-VBR and nrt-VBR Connections

The rt-VBR and nrt-VBR connections use different queues on a port, these are the rt-VBR and nrt-VBR queues, respectively. You can configure these separately, using the cnfportq command.

See Example 2 for a sample cnfportq screen showing configuration parameters available for a port queue.

Full Name

Configure port queue parameters

Syntax

cnfportq <port> [<params>]

Related Commands

upport, dnport, dspportq

Attributes

Privilege Jobs Log Node Lock

2

Yes

Yes

IGX, BPX

Yes

Example 1

cnfportq 4.2 200 80 60 80 1000 80 60 80 9800 80 60 80

Description

Configure port 4.2 to the parameters indicated.

System Response
ca19 VT SuperUser BPX 8620 9.2 June 23 1999 19:11 GMT ASI-T3 Port: 4.2 [ACTIVE] Interface: T3-2 Type: UNI Speed: 96000 (cps) SVC Queue Pool Size: 0 CBR Queue Depth: 200 rt-VBR Queue Depth: 1000 CBR Queue CLP High Threshold: 80% rt-VBR Queue CLP High Threshold: 80% CBR Queue CLP Low Threshold: 60% rt-VBR Queue CLP Low Threshold 60% CBR Queue EFCI Threshold: 80% rt-VBR Queue EFCI Threshold 80% nrt-VBR Queue Depth: 1000 UBR/ABR Queue Depth: 9800 nrt-VBR Queue CLP High Threshold: 80% UBR/ABR Queue CLP High Threshold: 80% nrt-VBR Queue CLP Low Threshold: 60% UBR/ABR Queue CLP Low Threshold: 60% nrt-VBR Queue EFCI Threshold: 80% UBR/ABR Queue EFCI Threshold: 80% Last Command: cnfportq 4.2 N N N 200 80 60 80 1000 80 60 80 9800 80 60 80 Next Command:
Example 2

cnfportq 2.2

Description

Configure the port queue parameters on port 2.2.

System Response
pubsbpx1 TN silves:1 BPX 8620 9.2.2G July 16 1999 10:47 PDT Port: 2.2 [ACTIVE ] Interface: LM-BXM Type: UNI Speed: 353208 (cps) SVC Queue Pool Size: 0 CBR Queue Depth: 600 rt-VBR Queue Depth: 0 CBR Queue CLP High Threshold: 80% rt-VBR Queue CLP High Threshold: 80% CBR Queue CLP Low Threshold: 60% rt-VBR Queue CLP Low/EPD Threshold: 60% CBR Queue EFCI Threshold: 60% rt-VBR Queue EFCI Threshold: 80% nrt-VBR Queue Depth: 5000 UBR/ABR Queue Depth: 20000 nrt-VBR Queue CLP High Threshold: 80% UBR/ABR Queue CLP High Threshold: 80% nrt-VBR Queue CLP Low Threshold: 60% UBR/ABR Queue CLP Low/EPD Threshold:60% nrt-VBR Queue EFCI Threshold: 60% UBR/ABR Queue EFCI Threshold: 20% This Command: cnfportq 2.2


Table 9-17: cnfportq—ASI Parameters
Parameter Description

slot.port

Specifies the ASI card slot and port number.

nni/uni

Specifies whether the cell header format is NNI or UNI. UNI is the default.

cbr queue parms

Specifies the CBR queue parameters of depth, cbr-hi, cbr-lo, and efci. The ranges are 0 to 24000 for depth and 0 to 100% for all others.

nrt-vbr queue parms

Specifies the nrt-VBR queue parameters of depth, vbr-hi, vbr-low, and efci. The ranges are 0 to 24000 for depth and 0 to 100% for all others.

rt-vbr queue parms

Specifies the rt-VBR queue parameters of depth, vbr-hi, vbr-low, and efci. The ranges are 0 to 24000 for depth and 0 to 100% for all others.

ubr/abr queue parms

Specifies the ABR queue parameters of depth, abr-hi, abr-low, and efci. The ranges are 0 to 24000 for depth and 0 to 100% for all others.


Table 9-18: cnfportq—UXM Parameters
Parameter Description

slot.port

Specifies the UXM card slot and port number.

nni/uni

Specifies whether the cell header format is NNI or UNI. UNI is the default.

cbr queue parms

Specifies the CBR queue parameters of depth, cbr-hi, cbr-lo, and efci. The ranges are 0 to 97250 for depth and 0 to 100% for all others.

nrt-vbr queue parms

Specifies the nrt-VBR queue parameters of depth, vbr-hi, vbr-low, and efci. The ranges are 0 to 97250 for depth and 0 to 100% for all others.

rt-vbr queue parms

Specifies the rt-VBR queue parameters of depth, vbr-hi, vbr-low, and efci. The ranges are 0 to 97250 for depth and 0 to 100% for all others.

ubr/abr queue parms

Specifies the ABR queue parameters of depth, abr-hi, abr-low, and efci. The ranges are 0 to 97250 for depth and 0 to 100% for all others. UBR traffic shares this queue with the ABR traffic.


Note   The total queue size of the UXM card is 97250 cells.

delcon

Removes connections from the network. The same command with differing syntax may be used to delete voice connections, data connections, Frame Relay connections, or ATM connections. The syntax in this section deletes an ATM connection. You can verify connection deletions by using the dspcons command.

In Release 9.2.20, you can use delcon to delete data or FRP connections that are terminated on UXM/UXM-E cards for IGX 8400 interface shelves, and terminated on routing network feeder trunks for IGX 8400 routing nodes.

Full Name

Delete connections

Syntax

delcon <channel(s)>

Related Commands

addcon, dspcon, dspcons

Attributes

Privilege Jobs Log Node Lock

1-2

Yes

Yes

IGX, BPX

Yes

Example 1

delcon 4.1.1.4

Description

Delete connection 4.1.1.4. The connections to delete are highlighted, and a prompt appears asking you to confirm the deletion. Respond with "y", for yes, and connection 4.1.1.4 is deleted.

System Response
ca19 VT SuperUser BPX 15 9.2 Aug. 23 1997 20:36 GMT Local Remote Remote Route Channel NodeName Channel State Type Avoid COS O 4.1.1.4 ca20 12.1.1.4 Ok CBR 0 R 4.1.1.5 ca20 12.1.1.5 Ok VBR 0 R 4.1.1.6 ca20 12.1.1.6 Ok ABR 0 R 4.1.1.7 ca20 12.1.1.7 Ok VBR 0 R 4.2.1.1 ca20 12.2.1.1 Ok CBR 0 L 4.2.1.2 ca20 12.2.1.2 Ok VBR 0 L 4.2.1.3 ca20 12.2.1.3 Ok ABR 0 L Last Command: delcon 4.1.1.4 Delete connections? (y) Next Command:


Table 9-19: delcon—Parameters
Parameter Description

channel

Specifies the channel or set of channels for deleting connections. <channel> is specified in the following format:

slot.port.vpi.vci

dnport

Deactivates (or "downs") the specified ATM port. Before downing a port, you must remove all connections from the port.

Full Name

Down port

Syntax

dnport <port>

Related Commands

cnfport, dspport, upport

Attributes

Privilege Jobs Log Node Lock

1-2

Yes

Yes

IGX, BPX

Yes

Example 1

dnport 4.2

Description

Down port 4.2.

System Response
ca19 VT SuperUser BPX 15 9.2 Aug. 23 1997 19:49 GMT ASI Port States Port State 4.1 ACTIVE 4.2 INACTIVE Last Command: dspports Next Command: dnport 4.2


Table 9-20: dnport—Parameters
Parameter Description

port

Specifies the slot number and port number in the format slot.port.

dspatmcls

Displays the current parameters for an ATM connection class template. The number of classes is ten. The parameters and the values for each varies with the type of connection (CBR, VBR, ABR, and ATFR).

In Release 9.2.20, both the dspatmcls and dspcls commands display

Full Name

Display ATM connection class

Syntax

dspatmcls <class number>

Related Commands

addcon, cnfatmcls, dspcls, cnfcls, dspcon, dspcons

Attributes

Privilege Jobs Log Node Lock

1-2

No

No

IGX, BPX

No

Example 1

dspatmcls 1

Description

Display the parameters for configuration class 1.

System Response
night TN SuperUser BPX 8620 9.2 July 28 1997 13:22 GMT ATM Connection Classes Class: 1 Type: VBR UPC SCR IBS MBS ABR PCR ABR PCR y 500/500 10/10 1000/1000 - 500/500 -/- ICR ICR TO Rate Up Rate Dn Rate FastDn Max Adjust CDVT[in cells] -/- - - - - - 64000/64000 EFCI % Util FGCRA MFS CLP CLP Hi CLP Lo BCM 100/100 100/100 n/n -/- y 100/100 100/100 n/n Description: "Default VBR 500" Last Command: dspatmcls 1 Next Command:
Example 2

dspatmcls 1

Description

Display the parameters for configuration class 1.

System Response
night TN SuperUser BPX 8620 9.2 July 28 1997 13:22 GMT ATM Connection Classes Class: 3 Type: rt-VBR PCR(0+1) %Util CDVT(0+1) AAL5 FBTC SCR 2000/2000 100/100 10000/10000 n 2000/2000 MBS Policing 1000/1000 3 Description: "Default rt-VBR 2000" Class: 4 Type: rt-VBR PCR(0+1) %Util CDVT(0+1) AAL5 FBTC SCR 8000/8000 100/100 10000/10000 n 8000/8000 MBS Policing 1000/1000 3 Description: "Default nrt-VBR 8000" Last Command: dspatmcls 1 Next Command:


Table 9-21: dspatmcls—Parameters
Parameter Description

class number

Specifies the class whose current parameters you want to see. Values are 1-10.

dspchstats

Displays statistics for a channel. You can specify an optional parameter interval, and the statistics display will be refreshed by the number of seconds you specify. (You can press the Delete key to stop the screen refresh.) If you do not specify the interval parameter, the screen refresh interval defaults to 10 seconds.

In this release, the multilevel channels statistics feature provides additional levels of channel statistics configuration for the BXM/UXM cards. You can use the cnfcdparm command to configure the channel statistic level on the BXM and UXM cards. For more information see the cnfcdparm command description in the Cisco WAN Switching SuperUser Command Reference.

The system responses that follow display the following statistics categories:

Full Name

Display channel statistics

Syntax

dspchstats <channel> [interval]

Related Commands

clrchstats

Attributes

Privilege Jobs Log Node Lock

5

No

No

IGX, BPX

No

Example 1

dspchstats 4.1.50.1

Description

Display the channel statistics for connection 4.1.50.1.

System Response
night TN SuperUser BPX 15 9.2 July 17 1997 02:46 GMT Channel Statistics for 4.1.50.1 Cleared: July 13 1997 02:53 (|) MCR: 0 cps Collection Time: 0 day(s) 18:10:22 Corrupted: NO Traffic Cells CLP Avg CPS %util Discards: Cells From Port : 14710 0 0 0 VcQ > CLP: 0 To Network : 14710 --- 0 0 VcQ Full : 0 From Network: 14710 --- 0 0 Qbin Full: 0 To Port : 14710 14710 0 0 Qbin> CLP: 0 Failed : 14710 OAM Cells RsrcOVL : 0 VC Q : 0 Tx OAM : 29608 NonCompliant: 0 Rx EFCI : 0 Rx AIS : 14710 Tx EFCI : 0 Rx FERF: 0 ForeSight Cells Rx BCM : 0 Adj Up : 0 Tx BCM : 0 Adj Dn : 0 AAL-5 Frames: 0 Adj Fdn: 0 This Command: dspchstats 4.1.50.1 Hit DEL key to quit:
Example 2

dspchstats 13.1.100 10

Description

Display statistics for connection 13.1.100 with a 10-second interval between screen updates. The card in slot 13 is an ALM/A.

System Response
sw142 TN SuperUser IGX 16 9.2 July 31 1997 14:38 PDT Channel Statistics: 13.1.100 Cleared: July 31 1997 11:50 (/) MCR: 150 cps Collection Time: 0 day(s) 00:00:00 Corrupted: NO Cells Avg Util (cps) (%) From Port: 0 0 0 To Network: 0 0 0 Discarded: 0 0 0 From Network: 0 0 0 To Port: 0 0 0 Discarded: 0 0 0 This Command: dspchstats 13.1.100 Hit DEL key to quit:
Example 3

dspchstats 9.2.1.100

Description

Display statistics for connection 9.2.1.100. The card in slot 9 is a UXM.

System Response
sw199 TN SuperUser IGX 16 9.0.s6 Aug. 28 1997 09:25 PDT Channel Statistics: 9.2.1.100 Snapshot Collection Time: 0 day(s) 13:28:47 Clrd: 08/27/97 19:47:24 Type Count Cells Received from Port 0 Cells Transmitted to Network 0 Cells Received from Network 0 Cells Transmitted to Port 0 EOF Cells Received from Port 0 Cells Received with CLP=1 0 Cells Received with CLP=0 0 Non-Compliant Cells Received 0 Average Rx VCq Depth in Cells 0 Average Tx Vcq Depth in Cells 0 Cells Transmitted with EFCI=1 0 Cells Transmitted with EFCI=0 0 Ingress Vsvd Allowed Cell Rate 0 Egress Vsvd Allowed Cell Rate 0 OAM state (0:OK,1:FERF,2:AIS) 0 Good Pdu's Received by the Sar 0 Good Pdu's Transmitted by the Sar 0 Rx pdu's discarded by the Sar 0 Tx pdu's discarded by the Sar 0 Invalid CRC32 pdu rx by the sar 0 Invalid Length pdu rx by the sar 0 Shrt-Lgth Fail detected by the sar 0 Lng-Lgth Fail detected by the sar 0 Last Command: dspchstats 9.2.1.100
Example 4

dspchstats 2.1.1.1 1

Description

Display statistics for connection 2.1.1.1 (with a VPI of 1, and VCI of 1), and an interval of 1.

System Response
sw57 TRM StrataCom BPX 8620 9.2.zR Date/Time Not Set Channel Statistics for 2.1.1.1 Cleared: Date/Time Not Set (\) Snapshot MCR: 96000/96000 cps Collection Time: 0 day(s) 00:01:45 Corrupted: NO Traffic Cells CLP Avg CPS %util Chan Stat Addr: 30EBB36C From Port : 0 0 0 0 To Network : 0 --- 0 0 From Network: 0 0 0 0 To Port : 0 --- 0 0 NonCmplnt Dscd: 0 Rx Q Depth : 0 Tx Q Depth : 0 Rx Vsvd ACR : 0 Tx Vsvd ACR : 0 Bkwd SECB : 0 Bkwd Lost Cell: 0 Bkwd Msin Cell: 0 Bkwd BIPV : 0 Fwd SECB : 0 Fwd Lost Cell : 0 Fwd Msin Cell : 0 Fwd BIPV : 0 Last Command: dspchstats 2.1.1.1 1 Next Command: CD Minor Alarm
Example 5

dspchstats 10.1.205.101

Description

Display statistics for connection 10.1.205.101 (with a VPI of 205 and VCI of 101).

System Response
m2a TN StrataCom IGX 8420 9.2.zR May 14 1998 14:19 GMT Channel Statistics: 10.1.205.101 Collection Time: 0 day(s) 23:02:58 Clrd: 05/13/98 14:33:00 Type Count Traffic Rate (cps) Cells Received from Port 82978 From port 0 Cells Transmitted to Network 82978 To network 0 Cells Received from Network 82978 From network 0 Cells Transmitted to Port 82978 To port 0 EOF Cells Received from Port 0 Cells Received with CLP=1 0 Cells Received with CLP=0 82978 Non-Compliant Cells Received 0 Average Rx VCq Depth in Cells 0 Average Tx Vcq Depth in Cells 0 Cells Transmitted with EFCI=1 0 Cells Transmitted with EFCI=0 82978 This Command: dspchstats 10.1.205.101


Table 9-22: dspchstats—Parameters
Parameter Description

channel

Specifies the channel for statistics display, with format of slot.port.vpi.vci.


Table 9-23: dspchstats—Optional Parameters
Parameter Description

interval

Specifies the interval (in seconds) between updates of the statistics display. If you specify an interval, you can either press Delete to terminate the command or wait until the command times out. The default is 10 seconds.

If the Rx Q depth and the Tx Q depth fields remain "0", make sure that a value other than "0" is specified for the interval parameter.

Functional Description

The table provides some statistics information regarding the BXM SAR. The switch software collects miscellaneous statistics regarding the Monarch SAR (Segmentation, Assembly, and Reassembly).

Segmentation, Assembly, and Reassembly (SAR) Statistics for BXM Card

Table 9-24 provides some statistics information for SAR on the BXM card. Note that the object name typically maps to the screen field name on the dspchstats screen.


Table 9-24: SAR Statistics for BXM Card
Object ID Object Name Range/Values Default Description

01

Message Tag

Byte 0-3 : Tag ID

Byte 4-7 : IP Address

0

Identifier and source IP address sent with CommBus message. Both will be copied into the response, if any is to be sent.

02

Ingress Unknown AAL5 Discards

0 - 232-1

N/A

Number of unknown AAL5 PDUs discarded in the ingress.

03

Egress Unknown ALL5 Discards

0 - 232-1

N/A

Number of unknown AAL5 PDUs discarded in the egress.

04

Ingress Frame Ready FIFO Overruns

0 - 232-1

N/A

Number of ingress frame-ready FIFO overruns.

05

Egress Frame Ready FIFO Overruns

0 - 232-1

N/A

Number of egress frame-ready FIFO overruns.

06

Ingress Frame Ready FIFO Fulls

0 - 232-1

N/A

Number of ingress frame-ready FIFO fulls.

07

Egress Frame Ready FIFO Fulls

0 - 232-1

N/A

Number of egress frame-ready FIFO fulls.

08

Ingress Frame Ready FIFO Half-Fulls

0 - 232-1

N/A

Number of ingress frame-ready half-fulls.

09

Egress Frame Ready FIFO Half-Fulls

0 - 232-1

N/A

Number of egress frame-ready half-fulls.

0A

Inverse ARP Requests Rcv

0 - 232-1

N/A

Number of inverse ARP requests received.

0B

Inverse ARP Replies Rcv

0 - 232-1

N/A

Number of inverse ARP replies received.

0C

Bad /errored ARP packets rcv

0 - 232-1

N/A

Number of invalid or unknown type ARP packets received.

0D

Inverse ARP Requests Xmt

0 - 232-1

N/A

Number of inverse ARP requests transmitted.

0E

Inverse ARP Replies Xmt

0 - 232-1

N/A

Number of inverse ARP replies transmitted.

0F

Errored ARP packet Xmt

0 - 232-1

N/A

Number of invalid or unknown type ARP packets transmitted.

10

Bad LLC/NSAP PDUs Rcv

0 - 232-1

N/A

Number of illegal LLC/NSAP packets received.

dspcls

Displays the current parameters for a connection class template. The number of classes is ten. The parameters and the values for each varies with the type of connection (CBR, rt-VBR, nrt-VBR, ABR, and ATFR). (Note that connection parameters for the rt-VBR and nrt-VBR connection classes display separately.)

Full Name

Display connection class

Syntax

dspcls <class number>

Related Commands

addcon, cnfcls, dspcon, dspcons

Attributes

Privilege Jobs Log Node Lock

1-2

No

No

IGX, BPX

No

Example 1

dspcls 1

Description

Display the parameters for configuration class 1.

System Response
night TN SuperUser BPX 8620 9.2 July 28 1997 13:22 GMT ATM Connection Classes Class: 3 Type: rt-VBR PCR(0+1) %Util CDVT(0+1) AAL5 FBTC SCR 2000/2000 100/100 10000/10000 n 2000/2000 MBS Policing 1000/1000 3 Description: "Default rt-VBR 2000" Class: 4 Type: rt-VBR PCR(0+1) %Util CDVT(0+1) AAL5 FBTC SCR 8000/8000 100/100 10000/10000 n 8000/8000 MBS Policing 1000/1000 3 Description: "Default nrt-VBR 8000" Last Command: dspatmcls 1 Next Command:
Example 2

dspcls 1

Description

Display the parameters for configuration class 1.

System Response
night TN SuperUser BPX 15 9.2 July 28 1998 13:22 GMT ATM Connection Classes Class: 1 Type: VBR UPC SCR IBS MBS ABR PCR ABR PCR y 500/500 10/10 1000/1000 - 500/500 -/- ICR ICR TO Rate Up Rate Dn Rate FastDn Max Adjust CDVT[in cells] -/- - - - - - 64000/64000 EFCI % Util FGCRA MFS CLP CLP Hi CLP Lo BCM 100/100 100/100 n/n -/- y 100/100 100/100 n/n Description: "Default VBR 500" Last Command: dspcls 1 Next Command:


Table 9-25: dspcls—Parameters
Parameter Description

class number

Specifies the class whose current parameters you want to see. Values are 1-10.

dspcon

Displays connection information for a specified channel. The information displayed includes:

Any failures that affect the connection flash on the screen. For Frame Relay NNI ports, the NNI value indicates the A-bit value received across the NNI from the remote network. The status that may be displayed includes:

OK

Connection OK

FAILED

Connection failed

MISSING

VPI.VCI was deleted in other network at NNI. A previous status report indicated a valid VPI.VCI was present but an updated report did not.

UNUSED

Indicates the UNI port does not support reporting of NNI A-bit status

In release 9.2 switch software for an IGX 8400 routing hub, dspcon does the following:

In Release 9.2.20, rt-VBR and nrt-VBR connection service types display separately.

Full Name

Display connections

Syntax

dspcon <channel>

Related Commands

addcon, cnfcon, cnfpref, cnfrtcost

Attributes

Privilege Jobs Log Node Lock

1-6

No

No

IGX, BPX

No

Example 1

dspcon 12.1.1.5

Description

Display connection information for channel 12.1.1.5 (a VBR connection).

System Response
ca20 LAN SuperUser BPX 15 9.2 Aug. 29 1997 10:44 PST Conn: 12.1.1.5 ca19 4.1.1.5 VBR Status: Down SCR MBS PCR ABR PCR UPC FST CLP % util 1000/1000 10/10 500/500 --/-- y n y 100/100 Owner: LOCAL Restriction: NONE COS: 0 Group: NONE TestRTD: 16705 msec Path: Downed by user Pref: Not Configured ca20 ASI-T3 : OK ca19 ASI-T3 : OK Line 12.1 : OK Line 4.1 : OK Last Command: dspcon 12.1.1.5 Next Command:
Example 2

dspcon 12.1.1.4

Description

Display connection information for channel 12.1.1.4 (CBR).

System Response
ca20 LAN StrataCom BPX 15 9.2 Aug. 29 1997 10:42 PST Conn: 12.1.1.4 ca19 4.1.1.4 CBR Status: Down PCR CDVT MCR ABR PCR UPC FST CLP % util 100/100 10/10 --/-- --/-- y n y 100/100 Owner: LOCAL Restriction: NONE COS: 0 Group: NONE TestRTD: 0 msec Trunk Cell Routing Restrict: Y Max Cost: 100 Route Cost: 36 Path: Downed by user Pref: Not Configured ca20 ASI-T3 : OK ca19 ASI-T3 : OK Line 12.1 : OK Line 4.1 : OK Last Command: dspcon 12.1.1.4 Next Command:
Example 3

dspcon 12.1.1.100

Description

Display connection information for channel 12.1.1.100 (an ABR connection.)

System Response
ca20 LAN SuperUser BPX 15 9.2 Aug. 29 1997 10:31 PST Conn: 12.1.1.100 ca20 SCR MBS MCR ABR PCR UPC FST CLP % util 20000/20000 50/50 20000/20000 96000/96000 y y y 100/100 ForeSight RTD: 0 msec Path: Route information not applicable for local connections ca20 ASI-T3 : OK ca20 ASI-T3 : OK Line 12.1 : OK Line 12.2 : OK Last Command: dspcon 12.1.1.100 Next Command:
Example 4

dspcon 4.1.2.1

Description

Display connection information for channel 4.1.2.1 (an ATFST connection.)

System Response
sw53 TN SuperUser BPX 8620 9.2 July 26 1997 13:40 GMT Conn: 4.1.2.1 sw53 4.3.2.1 atfst Status: OK SCR MBS MCR ABR PCR UPC FST CLP % util 25/25 1000/1000 25/25 25/25 y y y 100/100 ForeSightRTD: 0 msec Path: Route information not applicable for local connections sw53 BNI-T3 : OK sw53 BNI-T3 : OK Line 4.1 : OK Line 4.3 : OK OAM Cell RX: Clear NNI : OK NNI : OK Last Command: dspcon 4.1.2.1 Next Command:
Example 5

dspcon 12.1.1.*

Description

Display connection information for channel 12.1.1.* (a CBR VP tunnelling DAX connection.)

System Response
sw224 TRM IGX 8420 9.2.a5 Mar. 5 1999 11:10 PST Conn: 12.2.1.* sw224 12.1.1.100 cbrvp Status:OK PCR(0+1) % Util CDVT(0+1) Policing 1000/1000 100/100 10000/10000 4/4 Pri: L Test-RTD: 0 msec Path: Route information not applicable for local connections sw224 UXM: OK sw224 UXM: OK Line 12.2 : OK Line 12.1 : OK OAM Cell RX: Clear NNI: OK NNI: OK This Command: dspcon 12.2.1.*


Table 9-26: dspcon—Parameters
Parameter Description

channel

Specifies the channel for which to display connection details. The command displays connection information for one channel at a time. You cannot specify a set of channels. Channel is specified in the following format:

slot.port.vpi.vci

dspconcnf

Displays the following information for a connection's configuration:

The rt-VBR and nrt-VBR connection service types will display separately.

Full Name

Display connection configuration

Syntax

dspconcnf <channel>

Related Commands

addcon, dspcon, dspcons, delcon

Attributes

Privilege Jobs Log Node Lock

1-6

No

No

BPX

No

Example 1

dspconcnf 3.1.1.1

Description

Display the configuration for 3.1.1.1.

System Response
sw60 TN SuperUser BPX 8620 9.2 Date/Time Not Set Conn: 3.1.1.1 sw60 3.1.1.1 abrstd Description: PCR(0+1) % Util MCR CDVT(0+1) AAL5 FBTC 96000/96000 100/100 96000/96000 10000/10000 n Last Command: dspconcnf 3.1.1.1 Next Command:
Example 2

dspconcnf 2.1.1.101

Description

Display the configuration for 2.1.1.101.

System Response
sw60 TN SuperUser BPX 8620 9.2 Date/Time Not Set Conn: 3.1.1.1 sw60 3.1.1.1 rt-vbr Description: PCR(0+1) % Util CDVT(0+1) AAL5 FBTC SCR ---------- ------ --------- --------- ----- 50/50 100/100 250000/250000 n 50/50 MBS Policing ---- --------- 500/500 3 Trunk Cell Routing Restrict: Y Last Command: dspconcnf 3.1.1.1 Next Command:


Table 9-27: dspconcnf—Parameters
Parameter Description

channel

Specifies the channel for which to display connection configuration. The command displays connection information for one channel at a time. You cannot specify a set of channels. Channel is specified in the following format:

slot.port.vpi.vci

dspcons

Displays information about the connections on an IGX or BPX node. (For information about dspcons for an MGX 8220 card, refer to the MGX 8220 Command Reference.)

Table 9-28 lists all possible information headings that appear in the display. The actual headings that appear depend on the choice of selected optional parameters—including no parameters. The screen examples reflect various optional parameters.


Note   This description contains all parameters that are displayed even though some parameters are meaningless on a BPX.

You can also use dspcons to display those connections that have failed the OAM loopback test.

In Release 9.2.20, dspcons will display the rt-VBR and nrt-VBR service types separately.

As you configure VP tunnelling connections on a node, you can display all the VP tunnelling connections on a particular node by using the dspcons -tun command. VP tunnelling connections are indicated by a connection type of "cbrvp", for example, in the Type column of the dspcons screen. For more information on VP tunnelling on UXM cards, see the IGX Installation and Configuration manual.


Table 9-28:
Headings in Connection Display
Fields Description

Local Channel

The connection's channel at this node.

Remote Node Name

The name of the node at the other end of the connection.

Remote Channel

The connection's channel at the remote node.

State

The state of the connection(s) are as follows.

OK-routed

Down-downed

Failed-unrouted, but trying

Type

The type of connection (nrt-vbr, cbr, abr, atfr, or atfst).

Route Avoid

The type of lines to avoid when routing (satellite lines, terrestrial lines, lines with zero code suppression).

COS

The Class Of Service.

Owner

The end of the connection in control of re-routing.

ABRSTD=OFF

The policing value for the connection.

Full Name

Display connections

Syntax

dspcons [start_channel] [nodename] [-f] [-v] [-d] [-atfr] [-abit] [-fabit] [-fail] [-down]

where

start_channel

The starting channel to display.

nodename

specifies that connections for only the named node appear in the display.

-f

specifies that the display show Frame Relay connections only.

-v

specifies that the display show only voice connections.

-d

specifies that the display show only data connections (in Kbps).

-atfr

specifies that the display show Frame Relay to ATM interworking connections (as well as atfr with ForeSight).

-abit

specifies that the display show status of the A-bit.

-fabit

specifies that the display show only connections with failed A-bits.

-down

specifies that the display show only downed connections.


Note   Some parameters may cause other parameters not to appear. Therefore, if you specify all parameters, some do not appear.

Related Commands

addcon, delcon

Attributes

Privilege Jobs Log Node Lock

1-6

No

No

IGX, BPX

No

Example 1

dspcons 4.1.1.4

Description

Displays all connections starting with 4.1.1.4.

System Response
ca19 VT SuperUser BPX 15 9.2 Aug. 23 1997 19:44 GMT Local Remote Remote Route Channel NodeName Channel State Type Avoid COS O 4.1.1.4 ca20 12.1.1.4 Ok CBR 0 R 4.1.1.5 ca20 12.1.1.5 Ok rt-VBR 0 R 4.1.1.6 ca20 12.1.1.6 Ok ABR 0 R 4.1.1.7 ca20 12.1.1.7 Ok nrt-VBR 0 R Last Command: dspcons Next Command:
Example 2

dspcons -abit

Description

Display the Abit status for all connections starting with 1.1.3.66.

System Response
sw81 TN SuperUser BPX 15 9.2 Aug. 14 1997 10:32 PST Local Remote Remote Local Remote Channel NodeName Channel State Abit Abit 1.1.3.66 sw81 1.1.3.66 Ok OK OK 1.1.3.67 sw81 1.1.3.67 Ok OK OK 1.1.3.68 sw81 1.1.3.68 Ok OK OK 1.1.3.69 sw81 1.1.3.69 Ok OK OK 1.1.3.70 sw81 1.1.3.70 Ok OK OK 1.1.3.71 sw81 1.1.3.71 Ok OK OK 1.1.3.72 sw81 1.1.3.72 Ok OK OK 1.1.3.73 sw81 1.1.3.73 Ok OK OK 1.1.3.74 sw81 1.1.3.74 Ok OK OK 1.1.3.75 sw81 1.1.3.75 Ok OK OK 1.1.3.76 sw81 1.1.3.76 Ok OK OK 1.1.3.77 sw81 1.1.3.77 Ok OK OK 1.1.3.78 sw81 1.1.3.78 Ok OK OK This Command: dspcons -abit Continue?
Example 3

dspcons

Description

Display connections

System Response
sw99 TN StrataCom BPX 8620 9.2.10 Aug. 27 1998 08:59 GMT Local Remote Remote Route Channel NodeName Channel State Type Avoid COS O ------- -------- ------- ----- ---- ----- --- -- 3.2.6.16 sw14 10.1.6.16 Ok rt-vbr 0 L 3.2.6.17 sw14 10.1.6.17 Ok rt-vbr 0 L 3.2.6.18 sw14 10.1.6.18 Ok rt-vbr 0 L 3.2.6.19 sw14 10.1.6.19 Ok rt-vbr 0 L 3.2.6.20 sw4 10.1.6.20 Ok rt-vbr 0 L 3.2.6.21 sw14 10.1.6.21 Ok nrt-vbr 0 L 3.2.6.22 sw14 10.1.6.22 Ok atfr 0 L 3.2.6.16 sw157 16.1.6 Failed atfr 0 L 3.2.6.17 sw157 16.1.7 Failed atfr 0 L 3.2.8.18 sw157 16.1.8 OAM-F atfr 0 L 3.2.8.19 sw157 16.1.9 OAM-F atfr 0 L Last Command: dspcons
Example 4

dspcons -oam

Description

Display connections that have failed the OAM loopback test.

System Response
sw99 TN StrataCom BPX 8620 9.2.10 Aug. 27 1998 08:59 GMT Local Remote Remote Route Channel NodeName Channel State Type Avoid COS O ------- -------- ------- ----- ---- ----- --- -- 3.2.6.16 sw157 16.1.6 OAM-F atfr 0 L 3.2.6.17 sw157 16.1.7 OAM-F atfr 0 L 3.2.8.18 sw157 16.1.8 OAM-F atfr 0 L 3.2.8.19 sw157 16.1.9 OAM-F atfr 0 L Last Command: dspcons -oam Next Command:


Table 9-29: dspcons—Optional Parameters
Parameter Description

start channel

Specifies the beginning channel to display. The start channel format is: slot.port.vpi.vci

If no starting channel is specified, the display begins with the first connected channel.

node name

Specifies that connections to a specific remote node are displayed.

-atfr

Frame Relay to ATM interworking connections

-abit

A-bit status

-fabit

Connections with A-bit errors

-fail

Failed connections

-down

Downed connections

Example 5

dspcons -tun

Description

Display only VP tunnelling connections on that node.

System Response
sw224 TRM StrataCom IGX 8420 9.2.a5 Mar. 5 1999 11:10 PST Local Remote Remote Channel NodeName Channel State Type Compress Code COS 12.1.1.100 sw224 12.2.1.* Ok cbrvp 12.2.1.* sw224 12.1.1.100 Ok cbr Last Command: dspcons

dsplmistats

Displays LMI statistics for a specified channel.

Full Name

Display LMI/ILMI statistics

Syntax

dsplmistats <port> [clear]


Note   On an access shelf, the dsplmistats command takes no arguments. On an IPX or IGX node, dsplmistats requires a trunk number. On a BPX node, dsplmistats requires the slot and port number.

Related Commands

none

Attributes

Privilege Jobs Log Node Lock

1-6

No

No

IGX, BPX

No

Example 1

dsplmistats 1.1

Description

Display LMI statistics for channel 1.1.1.1.

System Response
sw81 TN SuperUser BPX 15 9.2 Aug. 29 1997 14:44 PST Annex G LMI Statistics for slot:1 port:1 VPI.VCI: 0.0 Lmi enabled Lmi polling enabled Invalid Pdu Rx: 0 Status Polling Timer (T396) : 10 Invalid Pdu Len Rx: 0 Status Enquiry Timer (T393) : 10 Unknown Pdu Type Rx: 0 Max Status Enquiry Retry (N394): 5 Unknown IE Type Rx: 0 Update Status Timer (T394) : 10 Bad Transaction Rx: 0 Max Update Status Retry (N395) : 5 Status Rx: 77715 Spc Polling Timer : 3 Status Enq Tx: 77711 Spc Retry Timer : 0 Status Enq Rx: 77897 Spc Retry Counter : 1 Status Tx: 77897 Node Status Retry Timer : 0 Status Ack Rx: 1505 Node Status Retry Counter : 0 Update Status Tx: 1507 Node Status Polling Timer : 7 Update Status Rx: 2042 Status Ack Tx: 2042 Last Command: dsplmistats 1.1 Next Command:


Table 9-30: dsplmistats—Parameters
Parameter Description

port

Channel is specified in the format slot.port.


Table 9-31: dsplmistats—Optional Parameters
Parameter Description

clear

On a BPX node only, the optional clear argument clears the current statistics after dsplmistats executes.

Functional Description of LMI Statistics for BXM Card

An internal firmware command provides the capability for the controller card to fetch ILMI/LMI statistics on ILMI/LMI sessions on the BXM card. The BXM must be firmware-capable. Refer to LMI Statistics and Descriptions for dsplmistats (ATM) for BXM Card


Table 9-32: LMI Statistics and Descriptions for dsplmistats (ATM) for BXM Card
Object ID Object Name Range/Values Default Description

01

Message Tag

Byte 0-3 : Tag ID

Byte 4-7 : IP Address

0

Identifier and source IP address sent with CommBus message. Both will be copied into the response, if any is to be sent.

02

Port Number

1 - 12

R

Identifies the target port. If multiple port numbers are sent during the operation, then each port number object terminates the configuration for the string of objects for the previous port number.

03

Virtual Port #

1 - 255

R

Identifies the target virtual port.

04

Status Sync

0 - Clear

1 - Get Status

R

Sync up ingress status information to bcc

05

Session Status

0 - Okay

1 - Failed

0

Indicates whether or not the ILMI/LMI session on this logical interface is failed.

06

BPX/Feeder IP Address

0 - 232-1

0

Valid for feeder connections. Indicates the IP address of the Feeder

07

BPX/Feeder Name

Byte 0..8 : String

N/A

Valid for feeder connections. Indicates the name of the Feeder

08

BPX/Feeder Serial Number

Byte 0..8 : String

N/A

Valid for feeder connections. Indicates the serial number of the Feeder

09

BPX/Feeder Alarm Status

0 : Clear

1 : Minor

2 : Major

N/A

Valid for feeder connections. Indicates the alarm status of the Feeder

0A

BPX/Feeder Line Rate

0 - 232-1

N/A

Valid for feeder connections. Indicates the line receive rate of the Feeder

0B

BPX/Feeder LAN IP Address

0 - 232-1

0

Valid for feeder connections. Indications the LAN IP address of the feeder

0C-0F

RESERVED

10

ILMI Number of Get Req Rx'd

0 - 232-1

N/A

ILMI number of Get Requests received.

11

ILMI No. of Get Next Req Rx'd

0 - 232-1

N/A

ILMI number of Get Next Requests received.

12

ILMI No. of Get Next Req Tx'd

0 - 232-1

N/A

ILMI number of Get Next Requests transmitted.

13

ILMI No. of Set Req Rx'd

0 - 232-1

N/A

ILMI number of Set Requests received.

14

ILMI No. of Traps Rx'd

0 - 232-1

N/A

ILMI number of traps received.

15

ILMI No. of Get Resp. Rx'd

0 - 232-1

N/A

ILMI number of Get Responses received.

16

ILMI No. of Get Req. Tx'd

0 - 232-1

N/A

ILMI number of Get Requests transmitted.

17

ILMI No. of Get Resp. Tx'd

0 - 232-1

N/A

ILMI number of Get Responses transmitted.

18

ILMI No. of Traps Tx'd

0 - 232-1

N/A

ILMI number of traps transmitted.

19

ILMI Unknown PDUs Rx'd

0 - 232-1

N/A

ILMI number of unknown PDUs received.

1A-1F

RESERVED

20

LMI No. of Status Tx'd

0 - 232-1

N/A

LMI number of Status transmitted.

21

LMI No. Update Status Tx'd

0 - 232-1

N/A

LMI number of Update Status transmitted.

22

LMI No. of Status Ack. Tx'd

0 - 232-1

N/A

LMI number of StatusAck. transmitted.

23

LMI No. of Status Enq. Rx'd

0 - 232-1

N/A

LMI number of Status Enquiries received.

24

LMI No. of Status Enq. Tx'd

0 - 232-1

N/A

LMI number of Status Enquiries transmitted.

25

LMI No. of Status Rx'd

0 - 232-1

N/A

LMI number of Status received.

26

LMI No. Update Status Rx'd

0 - 232-1

N/A

LMI number of Update Status received.

27

LMI No. of Status Ack. Rx'd

0 - 232-1

N/A

LMI number of StatusAck. received.

28

LMI No. of Invalid PDU Rx'd

0 - 232-1

N/A

LMI number of invalid PDUs received.

29

LMI No. of Invalid PDU Len. Rx'd

0 - 232-1

N/A

LMI number of invalid PDU lengths received.

2A

LMI No. Unknown PDUs Rx'd

0 - 232-1

N/A

LMI number of unknown PDUs received.

2B

LMI No. of Invalid IEs Rx'd

0 - 232-1

N/A

LMI number of Information Elements received.

2C

LMI No. of Invalid T.ID Rx'd

0 - 232-1

N/A

LMI number of invalid Transaction IDs received.

dspport

Displays detailed status on a single specified ATM port. The more specific the port address in the command, the more detail is provided. A full description of these parameters is provided in the cnfport command.

Full Name

Display port

Syntax

dspport <slot.port>

Related Commands

cnfport, upport, dnport

Attributes

Privilege Jobs Log Node Lock

1-2

No

No

IGX, BPX

No

Example 1

dspport 4.1

Description

Display the status of ASI port 4.1.

System Response
swstorm TN SuperUser BPX 15 9.2 July 26 1997 17:57 GMT Port: 4.1 [ACTIVE ] Interface: T3-2 Type: UNI Speed: 96000 (cps) VBR Queue Depth: 10800 Protocol: NONE Last Command: dspport 4.1 Next Command:
Example 2

dspport 7.2

Description

Display the status of the primary link on port 2, slot 7, of an IMA line.

System Response
sw225 TN StrataCom IGX 16 9.3.00 Jun 19 1999 13:39 PST Port: 7.2 [ACTIVE ] IMA Port Group: 2-5 Interface: E1-IMA CAC Override: Enabled Type: UNI %Util Use: Disabled Speed: 13433 (cps) SIG Queue Depth: 640 Protocol: NONE Last Command: dspport 7.2


Table 9-33: dspport—Parameters
Parameter Description

slot.port

Specifies the slot number and port to display.

dspportq

Displays the port queue configuration for an ASI or BXM card on a BPX or a UXM card on an IGX. After you enter this command with the required slot and port number parameter, the display shows the detailed port queue configuration information shown in the example figure.

Full Name

Display port queue configuration.

Syntax

dspportq <slot.port>

Related Commands

cnfportq

Attributes

Privilege Jobs Log Node Lock

1-2

No

No

IGX, BPX

No

Example 1

dspportq 4.2

Description

Display the port queue configuration for 4.2.

System Response
ca19 VT SuperUser BPX 8620 9.2 June 23 1999 19:11 GMT ASI-T3 Port: 4.2 [ACTIVE] Interface: T3-2 Type: UNI Speed: 96000 (cps) SVC Queue Pool Size: 0 CBR Queue Depth: 200 rt-VBR Queue Depth: 1000 CBR Queue CLP High Threshold: 80% rt-VBR Queue CLP High Threshold: 80% CBR Queue CLP Low Threshold: 60% rt-VBR Queue CLP Low Threshold 60% CBR Queue EFCI Threshold: 80% rt-VBR Queue EFCI Threshold 80% nrt-VBR Queue Depth: 1000 UBR/ABR Queue Depth: 9800 nrt-VBR Queue CLP High Threshold: 80% UBR/ABR Queue CLP High Threshold: 80% nrt-VBR Queue CLP Low Threshold: 60% UBR/ABR Queue CLP Low Threshold: 60% nrt-VBR Queue EFCI Threshold: 80% UBR/ABR Queue EFCI Threshold: 80% Last Command: cnfportq 4.2 Next Command:
Example 2

dspportq 2.1

Description

Display the port queue configuration for 2.1

System Response
swstorm TN SuperUser BPX 8620 9.2 June 26 1998 18:01 GMT ASI-T3 Port: 2.1 [ACTIVE ] Interface: T3-2 Type: UNI Speed: 96000 (cps) SVC Quque Pool Size: 0 CBR Queue Depth: 200 rt-VBR Queue Depth: 1000 CBR Queue CLP High Threshold: 80% rt-VBR Queue CLP Hi-Threshold: 80% CBR Queue CLP Low Threshold: 60% rt-VBR Queue CLP Low Threshold: 60% CBR Queue EFCI Threshold: 80% rt-VBR Queue EFCI Threshold: 80% rt-VBR Queue Depth: 10800 UBR/ABR Queue Depth: 9800 rt-VBR Queue CLP High Threshold: 80% UBR/ABR Queue CLP High Threshold: 80% rt-VBR Queue CLP Low Threshold: 60% UBR/ABR Queue CLP Low Threshold: 60% rt-VBR Queue EFCI Threshold: 80% UBR/ABR Queue EFCI Threshold: 80% Last Command: dspportq 2.1 Next Command:


Table 9-34: dspportq—Parameters
Parameter Description

slot or slot.port

Specifies either the slot number or the slot and port number.

dspportstats

Displays a summary of port statistics for the ATM port specified. These include the cell count in the transmit and receive directions, and error counts associated with the port. The display indicates the date and time that the statistics were cleared and the statistics collection time since they were last cleared. Cells transmitted indicates the amount of data transmitted out the port to the user device. Cells received indicates the amount of data received from the user device at the port. Corrupted statistics result from channel/port loopbacks or port tests. A "yes" in this field indicates that such loopback or port tests have occurred since the statistics were last cleared.

Full Name

Display port statistics

Syntax

dspportstats <port> [interval]

Related Commands

clrportstats

Attributes

Privilege Jobs Log Node Lock

1-6

No

No

IPX, IGX

No

Example 1

dspportstats 11.1

Description

Display the statistics for ASI port 11.1.

System Response
PABPX001 VT StrataCom BPX 15 8.5.04 Feb. 27 1998 16:38 G+01 Port Statistics for 11.1 Cleared: Feb. 19 1998 18:26 Port Speed: 80000 cps Collection Time: 5 day(s) 09:54:37 Corrupted: NO Cells CLP (EFCI) Rx Port: 41735369 0 0 Tx Port: 55704628 0 0 Unknown Addr : 144592 Cell Buf Ovfl : 0 Nonzero GFC Ct: 0 Rcv Ais Count : 0 Rcv Ferf Count: 343 Rx BCM Cells : 0 Tx Pyld Err Ct: 0 Tx H Err Dscd : 0 Lst Un Vpi/Vci: 0.16 This Command: dspportstats 11.1 Hit DEL key to quit:


Table 9-35: dspportstats—Parameters
Parameter Description

slot.port

Specifies the ATM card set and port number.


Table 9-36: dspportstats—Optional Parameters
Parameter Description

interval

Specifies the refresh interval time for data. It can be specified between 1 and 60 seconds. The default interval is 1 seconds.

Note that you must specify a value other than 0 for the "interval" parameter. Otherwise, the screen displayed for a UXM and BMX card will be just a snapshot—it will not be updated periodically. If the Rx Q depth and the Tx Q depth on the BXM and UXM cards remain "0", specify a value for the interval parameter other than 0.

Statistics Supported for BPX ATM Ports (ASI or BXM Front Card)

The following 45 statistics are available for each BPX ATM port, with an ASI or BXM front card type, and T3, E3, or OC-3 back card type. (Note that the statistics names listed below are what displays in Cisco WAN Manager; the field name that appears on the dspportstats screen may vary slightly from the Cisco WAN Manager parameter/field name.)

1) Cell Buffer Overflow

2) Cells Rx w/CLP discarded

3) Cells Rx w/CLP=0

4) Cells Rx w/CLP=0 discarded

5) Cells Tx w/CLP=0

6) Egress OAM Cell Count

7) Egress RM Cell Count

8) Get Request Rx

9) Get Request Tx

10) Get Response Rx

11) Get Response Tx

12) GetNext Request Rx

13) GetNext Request Tx

14) Ingress RM Cell Count

15) Invalid LMI IE Rx

16) Invalid LMI Rx

17) Invalid LMI length Rx

18) Invalid Transaction IDs

19) Non-zero GFC Count

20) Number of BCM Cell Rx

21) Number of Cells Rx

22) Number of Cells Rx w/CLP set

23) Number of Cells Rx w/EFCI set

24) Number of Cells Tx

25) Number of Cells Tx w/CLP set

26) Number of Cells Tx w/EFCI set

27) OAM Cells Rx Count

28) Rx AIS Cell

29) Rx FERF Cell

30) SetRequest Rx

31) Status Ack Rx

32) Status Ack Tx

33) Status Enq Rx

34) Status Enq Tx

35) Status Rx

36) Status Tx

37) Trap Rx

38) Trap Tx

39) Tx Header Err Discard

40) Tx Payload Err Due to BIP-16 Err

41) Unknown LMI Rx

42) Unknown LMI Tx

43) Unknown VPI/VCI

44) Update Status Rx

45) Update Status Tx


Table 9-37: BPX Port Statistics Supported for ASI and BXM Front Cards
Statistics Name in Cisco WAN Manager Statistics ID

Cell Buffer Overflow

1

Cells Rx w/CLP discarded

42

Cells Rx w/CLP=0

40

Cells Rx w/CLP=0 discarded

41

Cells Tx w/CLP=0

43

Egress OAM Cell Count

44

Egress RM Cell Count

46

Get Request Rx

17

Get Request Tx

23

Get Response Rx

22

Get Response Tx

24

GetNext Request Rx

18

GetNext Request Tx

19

Ingress RM Cell Count

45

Invalid LMI IE Rx

38

Invalid LMI Rx

35

Invalid LMI length Rx

36

Invalid Transaction IDs

39

Non-zero GFC Count

2

Number of BCM Cell Rx

10

Number of Cells Rx

7

Number of Cells Rx w/CLP set

8

Number of Cells Rx w/EFCI set

9

Number of Cells Tx

11

Number of Cells Tx w/CLP set

14

Number of Cells Tx w/EFCI set

15

OAM Cells Rx Count

12

Rx AIS Cell

5

Rx FERF Cell

6

SetRequest Rx

20

Status Ack Rx

34

Status Ack Tx

29

Status Enq Rx

30

Status Enq Tx

31

Status Rx

32

Status Tx

27

Trap Rx

21

Trap Tx

25

Tx Header Err Discard

16

Tx Payload Err Due to BIP-16 Err

13

41) Unknown LMI Rx

37

Unknown LMI Tx

26

Unknown VPI/VCI

0

Update Status Rx

33

Update Status Tx

28

dsprtcache

This command displays the cache of all cost-based routing connections. The optional index parameter lets you specify a cache entry index. The optional c parameter clears the cache.

Full Name

Display cost-based route cache

Syntax

dsprtcache [index] [c]

[index] specifies the cache entry index

[c] specifies to clear the entire cache or a single entry

Related Commands

dspcon, cnfrtcost, cnfpref

Attributes

Privilege Jobs Log Node Lock

1-6

No

No

IGX, BPX

No

Example 1

dsprtcache

Description

Display route cache contents, and let you monitor and manually clear the cache.

System Response
pissaro TN StrataCom BPX 15 9.1 Jun. 18 1997 11:11 GMT Route Cache (Summary) Index Use No. Cost Delay Restrict Load VPC Hops RemoteNode
0 Yes 1 Yes No None VBR No 2 lautrec 1 Yes 6 Yes No *s BDB No 3 vangogh 2 Yes 9 Yes No None BDA No 3 matisse 3 Yes 3 Yes No *t BDB No 3 rousseau 4 Yes 1 Yes No None CBR No 3 seurat <- current
5 No 0 No No None --- No 0 ---
6 No 0 No No None --- No 0 ---
7 No 0 No No None --- No 0 ---
8 No 0 No No None --- No 0 ---
9 No 0 No No None --- No 0 ---
10 No 0 No No None --- No 0 ---
11 No 0 No No None --- No 0 ---
Last Command: dsprtcache Next Command:


Table 9-38: dsprtcache—Parameters
Parameter Description

index

Specifies a particular route entry within the cache. When used with the c parameter, the route is either displayed or cleared from the cache.

c

Clears the cache, or if you also enter the index parameter, clears the route cache specified by the index number.

upport

Activates a single port on an ASI or BXM card on a BPX or a UXM card on an IGX. If the port has not been configured, the default configuration values are used to configure the port.

Full Name

Up port

Syntax

upport <slot.port>

Related Commands

dnport, cnfport, upln

Attributes

Privilege Jobs Log Node Lock

1-2

Yes

Yes

IGX, BPX

Yes

Example 1

upport 4.2

Description

Activate port 2 on the ASI in slot 4.

System Response
ca19 VT SuperUser BPX 15 9.2 Aug. 23 1997 19:17 GMT Port: 4.2 [ACTIVE ] Interface: T3-2 Type: UNI Speed: 96000 (cps) CBR Queue Depth: 200 CBR Queue CLP High Threshold: 80% CBR Queue CLP Low Threshold: 60% CBR Queue EFCI Threshold: 80% VBR Queue Depth: 1000 ABR Queue Depth: 9800 VBR Queue CLP High Threshold: 80% ABR Queue CLP High Threshold: 80% VBR Queue CLP Low Threshold: 60% ABR Queue CLP Low Threshold: 60% VBR Queue EFCI Threshold: 80% ABR Queue EFCI Threshold: 80% Last Command: upport 4.2
Example 2

upport 5.1

Description

Activate port 1, in slot 5, the primary link for the IMA.

System Response
sw225 TN StrataCom IGX 8420 9.3.l3 Feb. 2 2000 10:15 GMT Port: 5.1 [ACTIVE ] Secondary Y Redundancy (Configuration not used) IMA Port Grp: 1-8 Interface: E1-IMA CAC Override: Enabled Type: UNI %Util Use: Disabled Speed: 35924 (cps) SIG Queue Depth: 640 Protocol: NONE Last Command: upport 5.1


Table 9-39: upport—Parameters
Parameter Description

slot.port

Specifies the slot number of the card and the port to activate.