Problems Fixed in Release 9.2.37
Problems Fixed in Release 9.2.36
Problems Fixed in Release 9.2.35
Problems Fixed in Release 9.2.34
Problems Fixed in Release 9.2.33
Problems Fixed in Release 9.2.32
Problems Fixed in Release 9.2.31
Problems Fixed in Release 9.2.30
Problems Fixed in Release 9.2.23
Problems Fixed in Release 9.2.22
Problems Fixed in Release 9.2.21
Problems Fixed in Release 9.2.20
Problems Fixed in Release 9.2.10
Problems Fixed in Release 9.2.01
Additional Deliverables
Default Values
Appendix A
Appendix B
Obtaining Service and Support
Cisco Connection Online

9.2.37 Version Software Release Notes Cisco WAN Switching System Software


About These Release Notes

Cisco documentation and additional literature are available in a CD-ROM package, which ships with your product. The Documentation CD-ROM, a member of the Cisco Connection Family, is updated monthly. Therefore, it might be more current than printed documentation. To order additional copies of the Documentation CD-ROM, contact your local sales representative or call customer service. The CD-ROM package is available as a single package or as an annual subscription. You can also access Cisco documentation on the World Wide Web at http://www.cisco.com, http://www-china.cisco.com, or http://www-europe.cisco.com.

If you are reading Cisco product documentation on the World Wide Web, you can submit comments electronically. Click Feedback in the toolbar, select Documentation, and click Enter the feedback form. After you complete the form, click Submit to send it to Cisco. We appreciate your comments.

About the 9.2 Release

The 9.2 software release supports the Cisco WAN switching products, BPX 8600 series, and IGX 8400 series. This release does not support the IPX switch.

Phased Release Strategy

The MSSBU rollout plans for the 9.2 release is based upon a series of incremental feature releases. This phased feature release strategy is designed to allow the earliest customer availability of key new features, consistent with maintaining high product quality. For the latest status of each 9.2 feature, please see below.

The minimum release version noted in the table below represents the minimum switch software version required for each feature. As usual, it is recommended that customers use the most current maintenance releases.

Definitions

Generally Available (GA)—Feature is ready for wide deployment with no restrictions. Customers deploying GA features are supported by the Technical Assistance Center (TAC).

First Customer Ship (FCS)—Feature is available for controlled introduction by selected customers. To trial use an FCS feature, please contact your account representative.

Customers selected for controlled introduction will receive assistance with test plan review and special support from the New Product Team (NPT) in addition to the normal Technical Assistance Center (TAC) support.

Pre-First Customer Ship (Pre-FCS)—Feature is not yet available in the Switch Software baseline.

Target Date—This is the date for feature delivery that is supported by current Engineering and Marketing plans. This date is subject to change.

Product  Feature Name  FCS/GA Status  Minimum Release 

IGX

Support for UXM XLR card

GA

9.2.30

BPX

Support Multiple VSI Partitions

GA

9.2.30

IGX

HDM/LDM Control Lead Trap

GA

9.2.30

IGX

Support UXM Feeder

GA

9.2.30

IGX

SES Feeder to IGX

GA

9.2.20

BPX/IGX

A-bit Notification

GA

9.2.20

BPX/IGX

Real-Time VBR

GA

9.2.20

IGX

Support Enhanced UXM

GA

9.2.20

BPX

Support Enchanced BXM

GA

9.2.20

BPX

Support for 16K connections

GA

9.2.10

BPX

Support for Virtual Switch Interface (VSI) 2.2

GA

This interface is available in 9.2.10. Use of this interface is dependent upon other products, for example IOS.

BPX

Support for APS Annex B

GA

9.2.10

IGX

Support for UXM VP tunneling

GA

9.2.10

BPX

Include SONET line protection: APS on BXM-OC3 and BXM-OC12 (1+1)

GA

9.2.01

BPX

Support for Virtual Trunking on the BXM card

GA

9.2.01

BPX

Include SONET line protection: APS on BXM-OC3 and BXM-OC12 (2 card, 1:1)

GA

9.2.00

BPX

Support for LMI/ILMI on BXM card

GA

9.2.00

BPX/IGX

Alarms for all service-affecting events

GA

9.2.00

BPX/IGX

Support for feature mismatch on BXM and UXM cards

GA

9.2.00

BPX/IGX

Support for Hitless Rebuild including Disable Auto Bus Diagnostics

GA

9.2.00

BPX/IGX

Support for IGX and BPX trunk reconfiguration without outage

GA

9.2.00

BPX/IGX

Support for Revision Interoperability between 9.1 and 9.2

GA

9.2.00

BPX/IGX

Support for UXM and BXM Multilevel Channel Statistics

GA

9.2.00

BPX/IGX

Support ports and trunks on the same UXM and BXM cards

GA

9.2.00

IGX

Support for ATM Forum Standard Compliant IMA Trunking with UXM Firmware Model B

GA

9.2.00

IGX

Support for Virtual Trunking on the UXM card

GA

9.2.00

IGX

Support VC traffic shaping on UXM port

GA

9.2.00

IGX

Support for Idle code suppression for video on UVM and CVM cards

GA

9.2.00

Software Release 9.2.37

This is a maintenance release including all features supported up to Release 9.2.30. The following files will be extracted from a TAR file upon upgrading to Software Release 9.2.37.

Table 1   Release 9.2.37 BPX Files

File Name(s)  File Size (bytes) 

9237B.000 to 9237B.023

65536

9237B.024

45268

9237B.img

784

Table 2   Release 9.2.37 IGX Files

File Name(s)  File Size (bytes) 

9237G.000 to 9237G.025

65536

9237G.026

61695

9237G.img

784

Software Release 9.2.31, 9.2.32, 9.2.33, 9.2.34, 9.2.35, 9.2.36

This is a maintenance release including all features supported up to Release 9.2.30.

Software Release 9.2.30

Includes all features supported up to Release 9.2.20 and introduces the following additional features:

Software Release 9.2.23, 9.2.22, and 9.2.21

Includes all features supported up to Release 9.2.20.

Software Release 9.2.20

Includes all features supported up to Release 9.2.10 and introduces the following additional features:

Software Release 9.2.10

Includes all features supported up to Release 9.2.01 and introduces the following additional features:

Software Release 9.2.01

Includes all features supported in Release 9.2.00 and introducing the following additional features:

Software Release 9.2.00

Introduces the following features:

Clarifications

1. Release 9.2.31 introduced a new command—cnffdrlmiparms—which makes the feeder LMI timers and counters configurable. This command is currently supported on BPX only and cannot be added in the Job mode.

Usage: cnffdrlmiparms slot.port T393 T394 T396 N394 N395

where slot.port specifies the feeder trunk to configure. The details of the other parameters are as follows:

Timer  Description  Range (sec.)  Default (sec.) 

T396

LMI polling timer

5-30

10

T393

SPC STATUS ENQUIRY timer

5-30

10

T394

SPC UPDATE STATUS timer

5-30

10

N394

Max retry count for SPC STATUS

ENQUIRY/ REPORT procedures

1-10

5

N395

Max retry count for SPC UPDATE

STATUS / ACK procedures

1 -10

5

2. In Release 9.2.31 the system parameter 2 (cnfsysparm 2) is changed from "Fail Connections On Communication Break" to "Allow CPU Starvation of Fail Handler."

The old parameter has been removed as it violated the principle of the separating control and data plane. The new parameter allows a new feature to be turned off, which gives CPU to the Fail Handler at the expense of the Transaction Handler in case the Fail Handler does not get scheduled for a long time.

3. Do not mix MEE and MEF (or higher) in Y-red pairs for BXM 2-port group enhanced cards (OC-3 or OC-12 port). addyred will fail if both are in standby mode, or the primary card has been activated with MEF (or higher) and the secondary card has MEE.

4. For the BXM 2-port group, enhanced cards activated with MEF or higher, downrev to MEE will bring the cards into MISMATCH mode. This applies to both single cards and Y-red pairs.

5. Release 9.2.30 introduced four new commands in BPX:

6. There are changes in the following commands starting from Release 9.2.30:

7. The multiple partitions introduce two VSI partitions on trunk and port interfaces on the BXM card. One partition can be used for MPLS, and one can be used for PNNI. Virtual Trunk can have only one VSI partition or can be used for AutoRoute, but cannot be used for both VSI and AutoRoute simultaneously. This project introduces six service class templates in addition to the three existing templates.

Even though tag ABR is supported in Service Class Template (SCT), neither the MPLS controller nor the BXM firmware currently support this.

The configurable VPI/VCI introduces 2 new parameters in addctrlr and addshelf commands, through which the user can specify the VPI and VCI of the master-slave control channels.

8. There is a change in reporting of port group numbers in Release 9.2.32. Previous image (MEC) of BXM used to report a 1-port group for the 2-port group cards at the channel statistics level 2 and 3. This made the port belonging to second port group unusable.

Upgrading to 9.2.30 software first and then burning the BXM card with the MED or higher firmware, BXM will report 2-port groups for 2-port cards all the time. The smooth transition between the earlier 1-port group and the newly reported 2-port groups also displays the message in dspcd "Inconsistency with logical PG #" (port group number). All earlier software will "mismatch" the card.

If the BXM card is programmed with MEC or earlier firmware revision, the channel statistics for level 2 or 3 will report 1-port group. Burning an MED or higher image will result in 2-port groups, but for backwards compatibility the software will not do the recomputation of LCNs based on the new port groups. In its logical database, this will not impact the AutoRoute connections.

For VSI controllers the reported value will be higher than the actual available LCNs. That means a VSI controller may not be able to add connection even though the available connections are non-zero. If the user wishes to remove the above discrepancy, the card must be brought to the standby mode.

Note that the newly configured card or the card in standby mode programmed with MED or higher image brought to the active state will not have above discrepancy.

9. In BPX nodes that use processor cards with 32 MB of RAM, it is possible to run out of memory in the Hitless Region. This can happen if the node is too heavily configured with cards and connections. The recommendation below should prevent memory aborts.

In nodes that have processor cards with 64 MB of RAM, there should be no Hitless Region memory problem. This is because 64 MB processors contain a second Hitless Region, which is larger than the first.

The following calculation will help prevent memory aborts on BPX processors with 32 MB. For simplicity, the numbers are approximate. It is necessary to add up the number of cards in the node, as well as the number of connections, and make sure that the total does not exceed the recommendation.

During system initialization, roughly 17,100 blocks of the available 40,000 are used for the card database.

In addition, assume that 1500 blocks will be needed for each BXM card that can support 16K connections, which is the more common configuration. Some BXM cards can support 32K connections, and these will need 3000 blocks of the Hitless Region. This chunk of memory is allocated at the insertion of the BXM card and will not be released until a card of different type is inserted.

Also, 300 blocks will be needed for each 1000 via connections on the node. This can be viewed with the user command dspload.

    17100 blocks for card database
    1500 blocks for EACH BXM that supports 16K conns 
    3000 blocks for EACH BXM that supports 32K conns 
     300 blocks for EACH 1000 conns
   -----------------------------------------------------------------
   40000 blocks maximum total (34000 blocks for 9.2 releases up to 9.2.23)

10. The minimum software required to run MPLS are:

The BPX with an external 7x00 label switch controller (router) with Switch Software Release 9.2.10 and IOS Release 12.0(5)T can function as an ATM-LSR. The enhancements to dynamic label switching that was supported in Release 9.1 include support for MPLS Class of Service. The BPX as an ATM-LSR supports the "Multi-Label VC" model to support MPLS Class of Service. Five Qbins (Qbin 10-14) are reserved for MPLS Class of Service. Class-based WFQ is supported on these IP queues.

The BPX can also function as a "P" ATM-LSR in the MPLS-VPN architecture.

Hot redundancy of MPLS connections on the BPX is supported by BXM hot card redundancy. Continuous message forwarding, and keep-alive between the BXM redundant pair ensures the connection continuity on BXM switchover. On failure of a BXM card, the standby card becomes active with the label VCs. Resynchronization between the MPLS label switch controller and the BPX ensures that their databases are in sync.

11. The 16K connections feature increases the number of connections terminating on the BPX switch to 16,000. The count includes connections terminating on BXM or ASI endpoints on cards within the node as well as connections terminating on service modules in the feeder shelves connected to the BPX switch. For example, a Frame Relay connection that originates on an FRSM in an MGX 8220 connected to a BPX counts as one of the 16,000 terminated connections on that BPX.

This feature requires a BCC-3-64 or BCC-4 controller in the BPX as well as Switch Software 9.2.10 or higher.

12. Version 2.2 of the Virtual Switch Interface (VSI) provides the BPX switch with the ability to support multiple network protocols and multiple controllers per switch (for example, MPLS, PNNI, and so on). Switch resources can be dedicated to a specific controller or shared by multiple controllers.

This feature is supported on BXM ports, trunks, and virtual trunks and requires a BCC-3-64 or BCC-4 controller in the BPX as well as Switch Software 9.2.10 or higher and firmware MEA or higher.

Following are the VSI features:

13. The combinations of system limits such as the number of trunks, lines, ports, and connections as well as enabled TFTP interval statistics should be provisioned so that the node has at least 50 percent idle time usage. Use the command dspprfhist to verify.

14. When cost-based routing is used, increasing the cost of a trunk will result in deleting the preferred path on connections in the database if the sum of the preferred path cost exceeds the connection of configured cost. The connections will remain routed on its current path.

15. On the BXM and UXM, for the OC-3 MultiMode Fiber back cards, Y-Redundancy/hot standby is not supported due to hardware restrictions.

16. The trunk reconfiguration feature does not support IMA trunks.

Special Installation/Upgrade Requirements

General/Upgrade Procedure

Please consult your Support Representative before performing any software upgrade.

1. The earliest release supported for graceful upgrade is 9.1.03.

2. The 9.2 switch software requires MEB to MEJ firmware for BXM Model E cards.

3. Before upgrading to this release when UXM cards are to be used, certain legacy card firmware must be upgraded. See the compatibility matrix for cards affected and the exact versions to be used.


Note   Standards-compliant IMA is not compatible with the proprietary IMA protocol used in revision A firmware. Both ends of an IMA trunk must have the same protocol.


Caution   Failure to follow this procedure may result in the card not operating. The card should be returned to Cisco if this occurs:


Step 1   Verify current boot code version

In order to run Model B firmware on UXM, the card needs to be running boot code revision 6 or greater. To determine the boot code running on the card, issue the following command from CLI (user must be logged in as Service level or greater to use this command):

rsh <slot #> sys version 

Step 2   Upgrade UXM's boot code if necessary

The process for loading boot code is identical to the process you would use to load firmware. The only part that changes is the name of the file.


Note   Burning the boot code will cause the card to reset.

Step 3   Upgrade UXM's firmware

Step 4   When Y-redundant trunks are used, the red alarm in/out values must be configured to 1.25/1.5 seconds or greater, or else INVMUX failures will occur and trunk failures will be observed during a Y-redundancy switchover. Use the following command:

cnftrkparm

This is due to the IMA protocol and may cause reroute of connections.

Step 5   Upgrade NPM software to 9.2



4. Procedure for upgrading UXM-to-IMATM trunks from proprietary IMA protocol to ATM forum-compliant IMA protocol.


Step 1   Download and burn UXM bootcode version 6 or later to all UXMs in the network. This will cause the card to reset and reroute traffic to other trunks.

Step 2   On IGX, to have firmware upgrade, issue command cnffunc 15 d to disable the UXM from resetting automatically after the firmware is burned in.

Step 3   On each MGX 8220 equipped with IMATM-B, upgrade the ASC to 5.0.10.

Step 4   Download the Forum Compliant Firmware Version IMATM5.0.10.fw but do NOT reset the IMATM-B card.

Step 5   On each IGX-UXM with IMA to be upgraded, burn firmware ABE or later to each UXM with IMA trunks.

Step 6   Simultaneously reset the card at each end of each IMA trunk to minimize trunk outage.

Step 7   Upgrade 9.1 nodes to 9.2 via loadrev and runrev.

Step 8   Issue the command cnffunc 15 e after each IGX is upgraded to 9.2.20 or later.




Note   The above procedure also applies to the UXME.

5. Procedure for upgrading UXM-to-UXM trunks from proprietary IMA protocol to ATM forum-compliant IMA protocol.


Note   For Y-redundant UXMs, issue the command cnftrkparm 18 100000 100000 prior to this procedure and return to default values after this procedure.


Step 1   Download and burn UXM bootcode version 6 or later to all UXMs in the network. This will cause the card to reset and reroute traffic to other trunks.

Step 2   On IGX to have firmware upgraded, issue command cnffunc 15 d to disable the UXM from resetting automatically after the firmware is burned in.

Step 3   On each IGX-UXM with IMA to be upgraded, burn firmware ABE or later to each UXM with IMA trunks.

Step 4   Simultaneously reset the card at each end of each IMA trunk to minimize trunk outage.

Step 5   Upgrade 9.1 nodes to 9.2 via loadrev and runrev.

Step 6   Issue the command cnffunc 15 e after each IGX is upgraded to 9.2.20 or later.




Note   The above procedure also applies to the UXME.

6. Procedure for upgrading BXM cards to the 9.2 firmware release.

To enable BXM cards to utilize 9.2 features, all BXM cards must be upgraded to the 9.2 firmware release. The following steps should be taken to avoid card mismatch:

For the switch running

Perform the following steps to avoid card mismatch:


Step 1   Upgrade BXM firmware to MEB.

Step 2   Upgrade BCC software to 9.2.30 or higher.

Step 3   Upgrade BXM firmware to MEC or higher (optional).



For all other cases, do the following steps:


Step 1   Upgrade BXM firmware to MEB or higher.

Step 2   Upgrade BCC software to 9.2.30 or higher.




Note    See the Compatibility Matrix for the exact versions to be used.

7. Procedure for adding new BCC cards as a part of upgrading to the 9.2 release.

8. Upgrading VSI 1.1 in Release 9.1 to VSI 2.2 in Release 9.2.


Step 1   Upgrade the Tag Switch Controller (TSC)

The TSC is upgraded to the CoS VSI Version Capable Release (IOS 12.XX). This image is VSI bilingual, meaning it understands both VSI Version 1 and Version 2.

Step 2   Upgrade the BXMs

All the BXM cards in the node are upgraded to Revision E, which is VSI Version 2 and CoS capable. After each BXM card is downloaded with the Revision E image, it temporarily experiences VSI outage until the BCC software is upgraded to the 9.2.37 image. The VSI outage during the upgrade is caused by the Revision E firmware not being backward compatible with VSI Version 1 features.

Note that from the TSC perspective, after a BXM is upgraded to the Revision E image, the interfaces that used to be on the card will "disappear." The TDP sessions that were on the interfaces will be lost. When all the BXMs are upgraded to the Revision E while still running Release 9.1 software on the BCC, the node will experience a complete outage of MPLS traffic. AutoRoute will have a hitless upgrade.

Step 3   Upgrade the BCC.

As the BCC is upgraded from software Release 9.1 to Release 9.2.37, the BCC recognizes the Revision E BXMs and downloads the VSI partition configuration. This causes the BXMs to issue ifc cfg traps to the TSC, allowing the TSC to rediscover all the MPLS interfaces on the BPX. The TDP sessions are reestablished and MPLS traffic starts flowing again through the BPX.




Note   The VSI 1.1 and VSI 2.2 are not interoperable.

Revision Interoperability Supported

Revision interoperating upgrades are supported, from the 9.1 to 9.2 releases of Switch software, with secondary revision incorporation for network lowest revision. This will lessen the risk of new features being enabled in a mixed network after the downgrade.

A "Secondary Revision" field in the node is used for the determination of the network lowest revision. Previous to this change, software used only the nodes primary revision.

The interoperability functionality uses network lowest revision for:

Version Compatibility Notes

For a complete list of firmware revisions supported, see the Compatibility Matrix document, which is included in this release package.

Control Card Requirements

All processor cards must be configured with a minimum of 32MB of RAM. This includes BCCs and NPMs. NPMs require at least 1MB of BRAM. To verify the BRAM size on IGX 8400 nodes, use the dspcd command.


Note   If any control cards contain less than 32MB of DRAM (these would be NPMs) then they must be replaced with cards containing at least 32MB of DRAM prior to upgrading to Release 9.2. The physical upgrade of the nodes with these control cards must be done according to the upgrade procedure defined as follows.

Control Card Boot Firmware Requirements

As specified next, the correct version of control card (CC) boot firmware must be installed on the cards prior to a software upgrade to Release 9.2.

BCC Type  Firmware 

BCC-32

H.B.J

BCC-3-32

H.C.M

BCC-3-64

H.D.M

BCC-4

H.E.M.

BCC-4V

H.H.M

NPM Type  Firmware 

NPM-32

R.B.S

NPM-64

R.C.S

NPM-32B

R.E.S

NPM-64B

R.F.S

With the new version of NPM boot code (RXS), the boot code upgrading does not require physical card resetting with the following steps:


Step 1   Burn the boot code on the active NPM (1).

Step 2   Execute the switchcc command and wait until the NPM(1) becomes standby. NPM(2) is now active.

Step 3   Execute the resetcd command to reset the standby (resetcd 1 h). Wait until the reset card NPM(1) becomes standby.

Step 4   Burn the boot code on the active NPM(2).

Step 5   Execute the switchcc command and wait until the NPM(2) becomes standby. NPM(1) is now active.

Step 6   Execute the resetcd command to reset the standby (resetcd 2 h). Wait until the reset card NPM(2) become standby.



Control Card Compatibility Requirements

Each redundant pair of BCC cards in a given BPX 8600 node must be of the identical type and memory configuration. That is, for example, if the active card is a BCC-3-32, then so must be the standby. BCC-3 cards with 32MB of RAM cannot be mixed with BCC-3 cards with 64MB of RAM.

Each redundant pair of NPM cards in a given IGX 8400 node must be of the identical type and memory configuration. That is, for example, if the active card is an NPM-32, then so must be the standby. NPM cards with 32MB of RAM cannot be mixed with NPM cards with 64MB of RAM. Also, NPM-64 cards cannot be mixed with NPM-64B cards.

This is a requirement for all software upgrade and downgrade procedures. It does not apply to the physical card upgrade procedure, described in the following section.

Control Card Physical Card Upgrade Procedure

When performing a control card (CC) upgrade, the following procedure must be used. This applies to all processors: BCCs, and/or NPMs.


Step 1   Remove the current standby CC front and back card. (Remove back card only applies to BCC.)

Step 2   Replace with new CC front and back cards. (Replace back card only apply to BCC.)

Step 3   Wait for the standby updates on the newly installed standby CC to complete.

Step 4   Issue a switchcc command to utilize the newly installed CC.

Step 5   Verify that the network is stable.

Step 6   Remove the current standby CC front and back card. (Remove back card only applies to BCC.)

Step 7   Replace with new CC front and back cards that are identical to the current active CC. (Replace back card only apply to BCC)

Step 8   Wait for the standby updates on the newly installed standby CC to complete.

Step 9   The CC physical upgrade is now complete.

Step 10   With the secondary card in the standby state, cause a switchover using the switchcc command. This will test that the hardware is working correctly.




Note   After Step 2, the node will contain a mix of an old type CCs and the new type CCs. This condition is permitted only while the standby updates to the new CC are in progress, which will take less than one hour. The time during which this mixture of CC types exists must be kept to a minimum by immediately replacing the second old type CC with the matching one of the new type.

Obsoleted

Notes and Cautions

Additional Notes:

1. Switch Software Release 9.2 is not compatible with UXM firmware Model A.

2. If attempting to burn UXM firmware Model B into UXM firmware Model A with 9.2 software, the firmware Model B will not be burned into the UXM card due to the incompatibility of software 9.2 and UXM firmware Model A. The UXM has to be returned to Cisco for service.

3. If using MEC or earlier BXM firmware and upgrading to MED or later, the version of switch software has to be upgraded first so that the BXM will report 2-port groups for 2-port cards all the time. The smooth transition between the earlier 1 port group and the newly reported 2-port groups also displays message in dspcd "Inconsistency with logical PG #" (port group number). All earlier software will mismatch the card. This applied to BXM-OC3 or BXM-OC12 and configured to channel statistic level 2 or higher.

4. Firmware MED and earlier supports APS Redundancy on Legacy BXM only.

5. Because of hardware limitations, BXM hardware is not able to recognize all user-programmed cell transmission rates. Rather only discrete transmission rates can be used instead.

The equation below shows what the BXM hardware actually transmits given a user configured cell rate. The transmitted cell rate is always less than or equal to the configured cell rate. To prevent any cell loss, the transmitted cell rate must be equal to the configured rate. To do so, a cell rate must be chosen from the table below.

The rate table below lists the highest 200 cell rates supported be BXM such that if used, will result in no cell loss (given cell traffic is less than configured cell rate). Additional rates can be calculated using 1470588/[n + (1/256)], where n is an integer.

The logic to calculate the actual cell transmission rate in a BXM card is as follows:

if (configured cell rate == full line cell rate) then
     transmitted cell rate = full line cell rate

else
     transmitted cell rate = from equation below or from table below


Example:

If a trunk is configured at 100,000 cells per second (cps), the actual transmitted cell rate is then 98,013 cps, any traffic sent over 98,013 cps would be discarded.

If a trunk is configured at 98,013 cps, then the actual transmitted cell rate is 98,013 cps with no cell loss.

Therefore, only rates in the table should be used. Otherwise, cell loss may be experienced. The table will not be exhausted at the end but still go on with the computing from the above equation.

1464865

56552

28832

19348

14559

11670

9738

8355

733860

54458

28278

19097

14416

11579

9674

8308

489558

52513

27744

18852

14277

11488

9611

8261

367288

50703

27231

18614

14139

11399

9549

8215

293888

49013

26736

18381

14005

11311

9487

8169

244938

47432

26258

18154

13872

11225

9426

8124

209966

45950

25798

17933

13743

11140

9366

8079

183733

44558

25353

17717

13616

11056

9307

8035

163327

43247

24923

17506

13491

10974

9248

7992

147001

42012

24508

17300

13368

10892

9190

7948

133642

40845

24106

17099

13248

10812

9133

7906

122509

39741

23717

16902

13129

10733

9077

7863

113088

38695

23341

16710

13013

10656

9021

7822

105012

37703

22976

16522

12899

10579

8966

7780

98013

36761

22623

16339

12787

10503

8912

7739

91889

35864

22280

16159

12677

10429

8858

7699

86485

35010

21947

15983

12568

10355

8805

7659

81681

34196

21625

15812

12462

10283

8753

7619

77383

33419

21311

15643

12357

10212

8701

7580

73515

32676

21007

15479

12254

10141

8650

7541

70014

31966

20711

15318

12153

10072

8599

7502

66833

31286

20423

15160

12053

10003

8549

7464

63927

30634

20143

15005

11955

9936

8500

7427

61264

30009

19871

14853

11859

9869

8451

7389

58814

29409

19606

14705

11764

9803

8403

7352

.....

 

 

 

 

 

 

 

6. On the BPX with MGX 8220 feeder(s), regardless of the setting of the Node Parameter "42 Enable Feeder Alert," a feeder alert message will be sent to all MGX 8220 feeders immediately before a hitless rebuild takes place. The feeder alert message will temporarily disable the LMI polling from the MGX 8220 feeders. The MGX 8220 polling will resume as soon as the BPX is ready to exchange LMI messages.

7. The amount of traffic allowed on a VP tunneling connection is two-thirds bandwidth of that connection. The minimum bandwidth must be 100 cells per second. For example, a CBR connection with a peak cell rate 1500 cps then can pass traffic up to 1000 cps.

Limitations

1. BME firmware MKA and MKB is not compatible with BPX Switch Software Release 9.2x and later.

2. For Switch Software 9.2, MPLS and PNNI controllers cannot coexist.

3. In Release 9.2.30 and later, nodes might declare a communication break when using the BXM virtual trunking feature. The problem has been observed under the following conditions:

The simplest example follows below:

node_A ------ vtrk ----- node_B -----vtrk -----node_C

On the above diagram, node_B is a virtual trunk share a common port

With this topology, "node_A" sees "node_C" as unreachable and vice-versa; however, "node_A" communicates to "node_B," and "node_B" communicates to "node_C."

Workarounds:

4. When the cnfrsrc command is used to delete VSI partitions on an interface, software does not check if any Soft Permanent Virtual Circuit (SPVC) connections exists on that partition. Even if there are SPVC connections on a partition, the partition can be deleted using the cnfrsrc command. The only protection is that users are provided with a warning when they try to delete the partition.

If there are SPVC connections on a partition and if the partition is deleted, the SPVC connections will be left in a undefined and unrecoverable state. Hence, before deleting a VSI partition, ensure that all the SPVC connections are deleted on that partition.

5. For UVM cards, there will be no new revisions of Model A firmware. When attempting to download Model A firmware to a UVM, software will give the user an error message indicating that the firmware does not match the card type. Note that there is no problem with continuing to use existing UVM cards running the old firmware(CSCdp08741).

6. There is a new traffic class added in Release 9.2.20 that causes a trunk parameter conflict with pre-9.2.20 node. The conflict fails adding trunk between 9.2.20 BTM/ATM and pre- 9.2.20 BTM/ATM.

All ATM traffic classes are set for BTM/ALM trunks and is hidden to the user. The introduction of rt-VBR traffic class in 9.2.20 makes it different from pre-9.2.20 BTM/ALM trunk traffic class. The user can not change the ATM traffic class for BTM/ALM trunk.

This problem exists with a new BTM/ALM trunk on an upgraded 9.2.20 node but does not exist with an upgraded BTM/ALM trunk since the rt-VBR traffic class is not set while upgrading (CSCdm64345).

7. The cloud port to which a virtual trunk is connected should have ILMI polling disabled. Otherwise, it could lead to a virtual trunk being clear on one end and declaring Virtual Trunk Path Failure at the other end (CSCdm52909).

8. In a BPX that contains BCC cards with 64MB, there is no limitation. All 12 available slots can contain BXM or Enhanced-BXM cards.

In a BPX that contains BCC cards with 32MB, a maximum of 10 legacy BXM cards are allowed. If some Enhanced-BXM cards are used in place of BXM, then each Enhanced-BXM will count as two BXM cards.

9. For performance reasons, AIS status of connections is not sent to the standby BCC. After switchcc, it may take a few minutes to update the AIS status of connections. If dspcon does not show the proper status of AIS or the dspalms screen shows an incorrect number of AIS, (after switchcc) wait for few minutes so that the status gets updated. (The dspalms and dspcon commands show the status of AIS.)

10. Hitless rebuild has similar limitations to that of a switchcc and full rebuild:

Some will be re-enabled automatically. These include:

All other statistics have to be re-enabled for collection after a hitless rebuild takes place. These mainly include the user statistics.

11. UVM cards in Y-redundancy will mismatch if one is burned with Idle Code Suppression Firmware and the other is not.

When installing/burning Idle Code Suppression Firmware on UVM pairs, the Y-redundancy must be removed, firmware in both UVM cards burned, and then the Y-redundancy can be restored.

12. Mismatch is reported when replacing a BXM card with another BXM card that has a different port group, even though both BXM cards have the identical channel number.

13. When upgrading from Release 9.1 to 9.2, the 9.1 statistics on BXM/UXM cards are supported to maintain compatibility. However, once a user configures a statistics level in 9.2, the statistics cannot be configured back to 9.1 statistics.

There is no 9.1 statistics support for BXM/UXM cards that were shipped with 9.2 firmware since the BXM/UXM card has the default level 1 statistics.

Therefore, when using a UXM with 9.2, a user must either:

OR

14. The BXM and UXM channel statistics level feature gives these cards the capability of collecting more than four statistics per connection. However, it is the controller card's limitations, available memory, and performance, that indicates how many statistics can actually be collected from the cards and then reported to the Cisco Wan Manager (CWM).

The BCC-3-64 can collect at most three interval statistics per connection when there are 16,000 AutoRoute (AR) connections configured on the node. (Interval statistics are those statistics that are reported to the CWM. They are often referred to as TFTP statistics.)

You can collect approximately 48,000 statistics (3 x 16,000) on the BCC-3-64. This is approximate because there are many variables that will affect this value, such as are peaks enabled, how many buckets are collected, are all connection of the same type, are trunk, line or port statistics enabled, and so on.

With this approximation of 48,000 statistics on the BCC-3-64, this then means that as a rough estimate you could enable 32 statistics on 1,500 connections, 48 statistics on 1,000 connections or nine statistics on 5,000 connections, and so on. The approximation formula being:

max_stats_per_connection = 48,000/number_of_connections

15. In Release 9.1, the UXM card ran a proprietary IMA communication protocol. This protocol matched that used on the MGX 8220 4 IMATM-B cards and hence could be connected together to form a trunk. In Release 9.2, standards-compliant IMA are supported on the UXM card. The standards-compliant IMATM-B on MGX 8220 5.0 is not yet released. Hence, when the network is upgraded to 9.2., the UXM will be running compliant IMA protocol and the IMATM-B will still be running the proprietary IMA communication protocol. They will no longer communicate and the trunk will fail. This will be fixed in the MGX 8220 5.0 release containing IMATM-B. However, it should be noted that an upgrade at that time will also incur some amount of downtime as there will be a difference in timing between the MGX 8220 upgrade and the switch software upgrade. There should be no effect to UXM-IMA trunks connected to other UXM-IMA trunks in 9.1 to 9.2 interoperability mode.

16. The transmit rate on an IGX IMA trunk can be altered at the local node with any trunk outage. It is possible that the transmit rates are different at the two ends of an IMA trunk. After this trunk is deleted, it cannot be added back unless the transmit rates are the same.

17. When doing a grouped upgrade from Release 9.1 to 9.2, the software error 1427 may be logged on the BPX/IGX node during a non-graceful upgrade. This error can be ignored since it is harmless to the network (CSCdm14613).

18. Reconfiguring trunk parameters might cause connections to be rerouted if the changed bandwidth load is smaller than what was used by the connections that use the trunk.

19. If LMI/ILMI is provided by the BCC:

The maximum possible number of ports on the BPX 8600 that can be configured with LMI/ILMI enabled is 52. However, each BPX will support up to a total of 16 feeder trunks and each feeder trunk will have LMI enabled. That is, if a BPX 8600 is configured with only two feeder trunks, then only (52 - 2) = 50 ports can have LMI/ILMI enabled.

If LMI/ILMI is provided by the BXM firmware:

20. Virtual Path Connections with cells whose VCI values are above 4095 will be transmitted correctly only if the path is exclusively through BXM trunks and terminate at BXM ports.

21. The feature of CIR=0 for Frame Relay connections is not supported for connections terminating between FRM cards in IGX nodes and FRSM cards in an MGX 8220 shelf.

22. SVC connections are derouted after decreasing the allocated bandwidth (increasing Statistic Reserve). It is the design intent that increasing the statistical reserve will cause SVC conns to derouted and not be rerouted (CSCst92308).

23. For the loadrev operation, it is important that the Cisco Wan Manager/TFTP buffers are maintained at their default size.

24. Due to a hardware limitation, the BNI trunk will send 13-15 percent more traffic than what it is configured for when the trunk is configured for less speed (cps) than the maximum port speed. This is especially important when the BNI trunk is connected to IMATM pairs, which carry less than T3 bandwidth.

25. When using the shift/no-shift feature on a BPX 8600 node's port card, controlled via the cnfport command, the other end of the connection must have the same setting. Otherwise, there will be a loss of continuity.

26. Due to trunk-based loading, any commands having to do with trunk loading and the load model (dspload chklm dsplm, and so on.) need to be done only after waiting a certain period of time. This time is a direct function of the trunk load update interval time (as configurable) plus the conditional update latency time.

27. The external ABR segment control loop on ForeSight (ABRFST) is an option at the user interface. It is supported by UXM-E/BXM-E but is not supported by UXM/BXM hardware. The user should not enable this option on ForeSight connections (CSCdi92451). In any case, there is no coupling between the loops.

28. The interface between a BXM feeder trunk and an MGX 8220 feeder is always considered to be an NNI interface. (CSCdj16808)

29. When adding more than 4000 connections on a BPX node, the VC polling rate must be changed to a higher interval, to accommodate the additional time needed to poll for the statistics for each VC. The cnfsysparm command, parameter 24, must be changed according to the following:

0-3999 connections

Polling Rate: 5 Minutes (or higher)

4000-7999 connections

Polling Rate: 10 Minutes (or higher)

> 8000 connections

Polling Rate: 15 Minutes

30. Given a connection that terminates on an IGX 8400 FRM at one end and an ASI on the other end, tstdelay initiated at the FRM end may not work if the ASI firmware is below the appropriate revision and does not support OAM cells as opposed to supervisory cells. This is because the updated BTM on the IGX will always generate OAM cells. Please check the Compatibility Matrix.

31. Because the detailed card error event log is not retained within BRAM, this information will be lost should a processor rebuild occur. Therefore, when issuing a dspcderrs command on a particular slot, the display will not show the detailed card error information should a rebuild event occur. This functionality has not been modified from previous releases.

32. When a physical-layer failure (for example, LOS) is detected on the BXM, a Major Alarm is generated, and any connection routed over that port is downed (fail state). The software sends a command to the remote end of the connection to generate AIS in the egress direction (CSCdj30543).

Impact:

Since the connection is in a failed state, AIS is generated in the upstream direction (in addition to the downstream direction). Although this does conform to the letter of the I.610 standard, this is not necessarily what a user would expect to see, because it interferes with the RDI response from the end-to-end connection termination point. (A fault in the downstream direction causes a fault in the upstream direction.)

Reason for the current implementation:

The BNI can not generate AIS. If there is a fault at a BNI trunk, the current mechanism is to cause AIS to be generated by the BXM port by downing the connection. Since the BXM can generate only OAM cells from the RCMP, and the RCMP is in the ingress path, the cells must be backward routed to the egress (egress QE). Also, since end-to-end OAM cells are required, the ingress QE must be configured to drop ALL cells in the ingress path. This creates a break in continuity in the opposite direction, and AIS cells must also be generated at the other end of the same connection, in the upstream direction of the original fault.

33. There are problems in the downgrade mechanism that can cause database corruption. If a downgrade is performed immediately after upgrading, the Stby_Info revision fields are not yet filled in on the new active CC. They don't get filled in until there is an upcard response from the new locked CC. This causes a restart instead of a switchcc. If the locked CC is reset, then downgrade immediately, a restart will occur instead of a switchcc. (CSCdj30811).

34. In order to test/simulate the Y-redundant switchover of ASI T3 or E3 pairs the resetcd command must be used, or by pulling out the active card. It will not be correctly simulated by doing a dncd (down card) on the active card. Using dncd will cause cell discards (CSCdj08923).

35. UBR traffic gains an advantage over ABR traffic when UBR and ABR PVCs are combined on the same network. This is because UBR and ABR PVCs share the same Qbin (Class of Service Queue) on the BXM card. ABR PVCs use a flow control mechanism, VSVD, which ensures that traffic sources slow down when the Qbin usage exceeds the EFCI threshold. However, UBR PVCs do not have this throttling mechanism. Therefore, ABR will throttle back whereas UBR will not. This unfair advantage is not considered a problem, since the decision to share a Qbin for ABR and UBR traffic was intentional. Any best-effort service that one would route over UBR can be routed over ABR(VSVD), with the additional benefit of protecting resources in the network. If UBR and ABR PVCs are required then:

Option 1: Consider adding all best-effort PVCs as UBR

Option 2: Isolate the ABR and UBR paths by using cnfpref command to ensure that ABR and UBR PVCs do not share the same queues.

Option 3: To provide UBR service on a connection, rather than setting up a UBR connection, do the following:


Step 1   Set up an ABRSTD connection.

Step 2   Enable VSVD.

Step 3   Disable FCES (Flow Control External Segment).

Step 4   Disable DEFAULT EXTENDED PARAMETERS.

Step 5   Choose policing option "4" to allow access as UBR.1 (PCR policing only). This connection has ABR VSVD in the network and allows UBR.1 access. The MCR for such ABRSTD connection may be set at the minimum acceptable value of 6 cells per second (explained later to do so).



To provide ABR service on a connection, set up an ABRSTD connection, enable VSVD and enable FCES to allow RM cells to be passed to and from customer equipment. The MCR for such ABRSTD connections can be set at any user-desired value.

When the network is experiencing congestion, all the affected ABRSTD connections, regardless of the services (ABR or UBR) they are carrying, will all be throttled back at the VSVD points at the network edge. During network congestion, connections carrying UBR services are virtually stopped (to a throughput of a mere 6 cps) while connections carrying ABR services can send at a much higher, user-desired MCR. This option would avoid that UBR service gains an unfair advantage over ABR service while sharing the same CoS queue.

36. Combining Frame Based Traffic Control (FBTC) and non-FBTC connections within a Class of Service can cause FBTC connections to not receive a fair share of bandwidth. For example, if VBR connections are added at a terminating port, and some of these VBR connections have FBTC enabled while other VBR connections have FBTC disabled, the VBR connections with FBTC disabled may obtain all of the excess bandwidth before the connections with FBTC enabled receive any of the excess bandwidth. The same holds true for ABR or UBR connections. This is relevant only where FBTC and non-FBTC connections share a Qbin, either at a port or at a trunk.

37. The maximum number of VC PARMs supported: 749 for BCC-32 MB, 2,999 for BCC-64 MB. (CSCdj48589).

VC PARMs are Virtual Circuit Parameters combinations/sets. One set of VC Parameter is used for each unique Virtual Circuit that has been provisioned. Identically provisioned VCs (exclusive of end points) use the same set of parameters. Thus, on a 32MB BCC, a total of 749 uniquely configured Virtual Circuits can be provisioned.

38. Care must be taken when changing the Deroute Delay parameter, which is controlled by the cnftrk command. This defaults to zero, but if set to anything but zero, connection rerouting, due to a trunk failure, will be delayed as provided by the parameter.

Required Workarounds

1. When adding a node into an existing network, ensure that its node number is unique prior to a actually adding it into the network. Use the rnmnd command, and renumber the individual node while it is still stand-alone. This will make the joining of this node much simpler, and will avoid the problem of a node renumbering an active network, as described below.

2. There is a problem with node renumbering. Node renumbering (the rnmnd command) should be executed only during a stable network environment and only if absolutely necessary. A stable network environment would be, for example, one in which no connection was added for the past 30 minutes and no topology change was made in the last hour and there are no alarms or node unreachabilities. Node renumbering must be done only when the network is stable to reduce the possibility of certain temporarily blocked messages during the node renumbering process from being delivered to the wrong nodes. This would occur after the completion of the node renumbering process. It is recommended that a node be renumbered prior to being added to the network.

3. The settling time for network-wide updates can take a long time in certain situations. Specifically, the settling time for updates due to network-wide topology changes and connections in a large network when a processor switchover occurs can take a long time. The time is proportional to the number of nodes as well as the number of connections. A general estimate would be 30 seconds per node. During the period of transitions (when the updates are occurring) some network operations such as adding connections might in some cases take somewhat longer to complete.

4. When using Cisco Wan Manager, there could be a problem with communicating with a node that just had a processor switchover. The problem is within the SPARCstation itself and its caching of EtherNet addresses. It can be solved by execution the following command on the workstation as the superuser: # arp -d <node_name>

5. Users may not use the command addcon slot.1-24 v to add 24 voice connections to a CVM/UVM at once. Instead, they must separate this activity into two or more commands, so that no more than 16 connections are added at once. This is an issue only for voice connections. Data connections can be added using the "1-24" syntax. This also applies when the CVM/UVM circuit line is an E1, in which case "1-32" would apply (CSCdj14319).

6. Statistics must be disabled prior to the start of an upgrade, prior to the issuing of the first loadrev command. Statistics should be disabled from the Cisco Wan Manager, which is the Statistics collection manager.

7. Statistics sampling must be disabled prior to the start of an upgrade (using off1/off2), prior to the issuing of the first loadrev command. Statistics sampling state machines should be disabled from the Command Line Interface.

8. When a switchcc is executed on a BPX 8600 configured with two BCC-4 cards and contains a BXM-622 trunk card, there may be a bad clock path problem reported. It is indicated as a Minor Alarm - bad clock path. This is a transitory problem, although the alarm indication persists. To clear this, execute the clrclkalm command.

Additional Documentation

The command dspbpnv can be issued to verify if the node has the new backplane or the old backplane. The following chart details the bit fields for the BCC Backplane NOVRAM format, the values in bytes numbered 4 and 5 describe the back plane type.

The command cnfbpnv can be used to configure the backplane, if backplane is so enabled.

16-Bit Word Byte # (hex) Contents

0

0,1

Hardware revision

1

2,3

Backplane Type (usually 0x65=101 decimal)

2

4,5

Backplane version (0x0000:old 0x0001:new)

3

6,7

Backplane serial number in ASCII - MSB

4

8,9

"

5

A,B

" LSB

6

C,D

Board FAB number, in ASCII - MSB

7

E,F

"

8

10,11

"

9

12,13

"

A

14,15

"

B

16,17

" LSB

C

18,19

Unused

D

1A,1B

Unused

E

1C,1D

Unused

F

1E,1F

Checksum bytes - CURRENTLY NOT SUPPORTED

On the node on which it is executed, it creates a loopback within the port such that the cells do not leave the card.

On the node on which it is executed, it creates a loop such that incoming cells are looped back to the other end.

Removes the loopback added by either of the above two commands.

This will enable the card-synchronization feature.

This will disable the card-synchronization feature.

In order for the feature to work, the line statistics sampling should always be enabled (via on2 1 command) and the front card installed must support the card-synchronization feature. The dspcd command provides an easy way to determine whether the front card supports this new feature. If the front card supports the feature, the following message is shown on the dspcd screen:

Front card supports card synchronization

Additional debug commands are added to allow synchronization between the interface card and the CC database:

The <slot_number> is for a particular slot that supports the card synchronization feature;
* For all cards that support the card-synchronization feature.

This command displays the number of connections reconciled during the synchronization process after a switchcc for different slots.

* For all slots supporting this feature.

Compatibility Notes

For a complete list of firmware revisions supported, see the Compatibility Matrix document, which is included in this release package.

This release will run with Release 4.0.0x, 4.1.0x, or 5.0.0x of the MGX 8220.

Compatibility Matrix

BPX 8600 Firmware Compatibility

PCB Description  dspcds Name  Card Name in FW Image   Model  Latest F/W  Min F/W 

BCC boot

BCC

BCC

B

HBJ

HBJ

BCC3-32 boot

BCC-3

BCC

C

HCM

HCM

BCC3-64 boot

BCC-3

BCC

D

HDM

HDM

BCC4 boot

BCC-4

BCC

E

HEM

HEM

BCC4-128 boot

BCC-4

BCC

H

HHM

HHM

ASI 2T3/2E3

ASI-T3

ASI

C

UCF

UCF

ASI 2T3/2E3

ASI-E3

ASI

C

UCF

UCF

ASI-155-E

ASI155E

ASI-155

E

WEC

WEC

ASI-155

ASI-155

ASI-155

H

WHC

WHC

ASM

ASM

 

A

GAC

GAC

BNI-3T3/3E3

BNI-T3

BNI

C

TCM

TCM

BNI-3T3/3E3

BNI-E3

BNI

C

TCM

TCM

BNI-155

BNI-155

BNI-155

B

VBR

VBR

BNI-155-E

BNI155E

BNI-155

D

VDR

VDR

BXM-BME

BME

BME

K

n/s

n/s

BXM-T3-8/12

BXM-T3

BXM

E

MEJ

MEB

BXM-T3-8/12

BXM-T3

BXM

F

MFJ

MFJ

BXM-E3-8/12

BXM-E3

BXM

E

MEJ

MEB

BXM-E3-8/12

BXM-E3

BXM

F

MFJ

MFJ

BXM-155-4/8

BXM-155

BXM

E

MEJ

MEB

BXM-155-4/8

BXM-155

BXM

F

MFJ

MFJ

BXM-622/622-2

BXM-622

BXM

E

MEJ

MEB

BXM-622/622-2

BXM-622

BXM

F

MFJ

MFJ

BXM-T3-8E/12E/12EX

BXM-T3

BXM

E

MEJ

MED

BXM-T3-8E/12E/12EX

BXM-T3

BXM

F

MFJ

MFJ

BXM-E3-8E/12E/12EX

BXM-E3

BXM

E

MEJ

MED

BXM-E3-8E/12E/12EX

BXM-E3

BXM

F

MFJ

MFJ

BXM-155-4D/8D/4DX/8DX

BXM-155

BXM

E

MEJ

MED

BXM-155-4D/8D/4DX/8DX

BXM-155

BXM

F

MFJ

MFJ

BXM-622-2D/DX/2DX

BXM-622

BXM

E

MEJ

MED

BXM-622-2D/DX/2DX

BXM-622

BXM

F

MFJ

MFJ

IGX 8400 Firmware Compatibility

PCB Description  dspcds Name  Card Name in Firmware Image   Model  Latest F/W  Min F/W 

NPM boot

NPM

NPM

A

RAS

RAR

NPM 32 boot

NPM

NPM

B

RBS

RBR

NPM 64 boot

NPM

NPM|NPM-64

C

RCS

RCR

NPM-B 32 boot

NPM

NPM|NPM-32B

E

RES

RER

NPM-B 64 boot

NPM

NPM|NPM-64B

F

RFS

RFR

IGX-ALM/A

ALM

ALM-A

A

CAF

CAE

IGX-ALM/B

ALM

ALM-B

B

CBL

CBH

IGX-BTM/B

BTM

BTM

A

IAF

IAF

IGX-BTM/B

BTM

BTM

B

IBL

IBL

IGX-BTM/B

BTM

BTM

D

IDC

IDC

IGX-CVM-DS0A

CVM

CVM

A

DAF

DAF

IGX-CVM

CVM

CVM

B

DBF

DBF

IGX-CVM-TT

CVM

CVM

C

DCA

DCA

IGX-FRM

FRM

FRM

D

FDZ

FDZ

IGX-FRM-31

FRM

FRM-31

E

FEZ

FEZ

IGX-FRM-2

FRM

FRM-2

F

FFD

FFD

FRM (B)

FRM

FRM

H

FHB

FHB

IGX-FRM

FRM

FRM

J

FJB

FJA

IGX-FRM-31

FRM

FRM-31

K

FKB

FKA

IGX-FTM

FTM

FTM

B

JBJ

JBJ

IGX-FTM

FTM

FTM

C

JCB

JCB

IGX-HDM

HDM

HDM

C

SCF

SCF

IGX-LDM

LDM

LDM

C

LCC

LCB

IGX-NTM

NTM

NTM

E

NEK

NEK

IGX-NTM (B)

NTM

NTM

F

NFK

NFH

IGX-UFM-4C/8C

UFM

UFM-C

A

ZAU

ZAN

IGX-UFM-4C/8C

UFM

UFM-C

B

ZBE

ZBA

IGX-UFM-8C

UFM

UFM-C

C

n/s

n/s

IGX-UFM-U

UFMU

UFM-U

A

YAM

YAH

IGX-UFM-U

UFMU

UFM-U

B

YBD

YBA

IGX-UFM-U

UFMU

UFM-U

C

n/s

n/s

IGX-UVM

UVM

UVM

A

DAE

DAC

IGX-UVM

UVM

UVM

B

DBD

DBD

IGX-UVM

UVM

UVM

C

DCA

DCA

IGX-UVM

UVM

UVM

D

DDF

DDF

IGX-UVM

UVM

UVM

E

DEH

DEA

IGX-UXM

UXM

UXM

B

ABL

ABB

IGX-UXME

UXM

UXM

B

ABL

ABB


Note   IGX-UVM model E is a superset of models A, B, and C firmware. A, B, and C are obsoleted and should not be used.

MGX 8220 Firmware Compatibility

    5.0 4.1 4.0
PCB Description  CW2000 Name  Latest F/W  Min F/W  Latest F/W  Min F/W  Latest F/W  Min F/W 

ASC F/W

ASC

5.0.15

5.0.10

4.1.08

4.1.00

4.0.21

4.0.04

ASC Boot

ASC

1.0.03

1.0.01

1.0.03

4.0.04

1.0.01

4.0.03

ASC/2 FW

ASC

5.0.15

5.0.10

4.1.08

4.1.00

4.0.21

4.0.09

ASC/2 Boot

ASC

1.0.03

1.0.01

1.0.03

4.0.04

1.0.01

4.0.04

ASC/2F FW

ASC

5.0.15

5.0.10

4.1.08

4.1.05

4.0.21

4.0.21

ASC/2F Boot

ASC

1.0.03

1.0.01

1.0.03

1.0.01

1.0.01

1.0.01

BNM-T3

BNM-T3

n/a

n/a

n/a

n/a

n/a

n/a

BNM-E3

BNM-E3

n/a

n/a

n/a

n/a

n/a

n/a

BNM-155

BNM-155

n/a

n/a

n/a

n/a

n/a

n/a

FRSM-4T1

FRSM-4T1

4.0.22

4.0.19

4.0.20

4.0.13

4.0.19

4.0.04

FRSM-4E1

FRSM-4E1

4.0.22

4.0.19

4.0.20

4.0.13

4.0.19

4.0.04

FRSM-4T1-C

FRSM-4T1-C

4.0.22

4.0.19

4.0.20

4.0.13

4.0.19

4.0.04

FRSM-4E1-C

FRSM-4E1-C

4.0.22

4.0.19

4.0.20

4.0.13

4.0.19

4.0.04

FRSM Boot

FRSM-4T1

4.0.00

4.0.00

4.0.00

4.0.00

4.0.00

4.0.00

FRSM Boot

FRSM-4E1

4.0.00

4.0.00

4.0.00

4.0.00

4.0.00

4.0.00

FRSM Boot

FRSM-4T1-C

4.0.00

4.0.00

4.0.00

4.0.00

4.0.00

4.0.00

FRSM Boot

FRSM-4E1-C

4.0.00

4.0.00

4.0.00

4.0.00

4.0.00

4.0.00

SRM T1E1 (B)

SRM-T1E1

n/a

n/a

n/a

n/a

n/a

n/a

SRM 3T3

SRM-3T3

n/a

n/a

n/a

n/a

n/a

n/a

CESM-4T1

CESM-4T1

4.0.17

4.0.15

4.0.16

4.0.11

4.0.15

4.0.04

CESM-4E1

CESM-4E1

4.0.17

4.0.15

4.0.16

4.0.11

4.0.15

4.0.04

CESM Boot

CESM-4T1

4.0.01

4.0.01

4.0.01

4.0.00

4.0.01

4.0.00

CESM Boot

CESM-4E1

4.0.01

4.0.01

4.0.01

4.0.00

4.0.01

4.0.00

CESM-8T1

CESM-8T1

5.0.13

4.1.05

4.1.08

4.1.00

n/s

n/s

CESM-8E1

CESM-8E1

5.0.13

4.1.05

4.1.08

4.1.00

n/s

n/s

CESM-8 Boot

CESM-8T1

1.0.01

1.0.01

1.0.01

4.1.00

n/s

n/s

CESM-8 Boot

CESM-8E1

1.0.01

1.0.01

1.0.01

4.1.00

n/s

n/s

AUSM-4T1

AUSM-4T1

4.0.21

4.0.19

4.0.20

4.0.13

4.0.19

4.0.04

AUSM-4E1

AUSM-4E1

4.0.21

4.0.19

4.0.20

4.0.13

4.0.19

4.0.04

AUSM Boot

AUSM-4T1

4.0.00

4.0.00

4.0.00

4.0.00

4.0.00

4.0.00

AUSM Boot

AUSM-4E1

4.0.00

4.0.00

4.0.00

4.0.00

4.0.00

4.0.00

FRSM-8T1

FRSM-8T1

5.0.14

5.0.10

4.0.20

4.0.13

4.0.19

4.0.04

FRSM-8E1

FRSM-8E1

5.0.14

5.0.10

4.0.20

4.0.13

4.0.19

4.0.04

FRSM-8T1 Boot

FRSM-8T1

1.0.02

1.0.01

1.0.02

4.0.01

1.0.01

4.0.00

FRSM-8E1 Boot

FRSM-8E1

1.0.02

1.0.01

1.0.02

4.0.01

1.0.01

4.0.00

AUSM-8T1

AUSM-8T1

5.0.13

5.0.10

4.0.21

4.0.14

4.0.20

4.0.04

AUSM-8E1

AUSM-8E1

5.0.13

5.0.10

4.0.21

4.0.14

4.0.20

4.0.04

AUSMB-8T1

AUSMB-8T1

5.0.13

5.0.10

4.0.21

4.0.19

4.0.20

4.0.19

AUSMB-8E1

AUSMB-8E1

5.0.13

5.0.10

4.0.21

4.0.19

4.0.20

4.0.19

AUSM-8T1E1 Boot

AUSM-8T1

1.0.02

1.0.01

1.0.02

4.0.01

1.0.01

4.0.00

AUSM-8T1E1 Boot

AUSM-8E1

1.0.02

1.0.01

1.0.02

4.0.01

1.0.01

4.0.00

AUSM-8T1E1 Boot

AUSMB-8T1

1.0.02

1.0.01

1.0.02

4.0.01

1.0.01

4.0.00

AUSM-8T1E1 Boot

AUSMB-8E1

1.0.02

1.0.01

1.0.02

4.0.01

1.0.01

4.0.00

FRSM-HS1

FRSM-HS1

5.0.13

4.0.16

4.0.17

4.0.11

4.0.16

4.0.04

FRSM-HS1/B

FRSM-HS1/B

5.0.13

4.0.16

4.0.17

4.0.11

4.0.16

4.0.04

FRSM-HS1 Boot

FRSM-HS1

1.0.01

1.0.01

1.0.01

4.0.00

1.0.01

4.0.00

FRSM-HS1 Boot

FRSM-HS1/B

1.0.01

1.0.01

1.0.01

4.0.00

1.0.01

4.0.00

FRSM-HS2

FRSM-HS2

5.0.13

5.0.10

n/s

n/s

n/s

n/s

FRSM-HS2 Boot

FRSM-HS2

1.0.01

1.0.01

n/s

n/s

n/s

n/s

IMATM

IMATM-T3T1

n/s

n/s

4.0.20

4.0.13

4.0.19

4.0.04

IMATM

IMATM-E3E1

n/s

n/s

4.0.20

4.0.13

4.0.19

4.0.04

IMATM

IMATMB-T1

5.0.13

5.0.10

4.0.20

4.0.13

4.0.19

4.0.04

IMATM

IMATMB-E1

5.0.13

5.0.10

4.0.20

4.0.13

4.0.19

4.0.04

IMATM Boot

IMATM-T3T1

n/s

n/s

1.0.02

4.0.01

1.0.01

4.0.01

IMATM Boot

IMATM-E3E1

n/s

n/s

1.0.02

4.0.01

1.0.01

4.0.01

IMATM Boot

IMATMB-T1

1.0.02

1.0.01

1.0.02

4.0.01

1.0.01

4.0.01

IMATM Boot

IMATMB-E1

1.0.02

1.0.01

1.0.02

4.0.01

1.0.01

4.0.01

MGX 8250 1.1.3x Firmware Compatibility

PCB Description  CW2000 Name  Latest F/W  Min F/W 

PXM1

PXM-1

1.1.32

1.1.32

PXM1-2-T3E3

PXM1-2T3E3

1.1.32

1.1.32

PXM1-4-155

PXM1-4OC3

1.1.32

1.1.32

PXM1-1-622

PXM1-OC12

1.1.32

1.1.32

MGX-SRM-3T3/C

SRM-3T3

n/a

n/a

AX-CESM-8E1

CESM-8E1

10.0.21

10.0.21

AX-CESM-8T1

CESM-8T1

10.0.21

10.0.21

MGX-AUSM-8E1/B

AUSMB-8E1

10.0.21

10.0.21

MGX-AUSM-8T1/B

AUSMB-8T1

10.0.21

10.0.21

MGX-CESM-T3

CESM-T3

10.0.21

10.0.21

MGX-CESM-E3

CESM-E3

10.0.21

10.0.21

AX-FRSM-8E1/E1-C

FRSM-8E1

10.0.21

10.0.21

AX-FRSM-8T1/T1-C

FRSM-8T1

10.0.21

10.0.21

MGX-FRSM-HS2

FRSM-HS2

10.0.22

10.0.22

MGX-FRSM-2CT3

FRSM-2CT3

10.0.22

10.0.22

MGX-FRSM-2T3E3

FRSM-2T3

10.0.22

10.0.22

MGX-FRSM-2T3E3

FRSM-2E3

10.0.22

10.0.22

MGX-FRSM-HS1/B

FRSM-HS1/B

10.0.21

10.0.21

MGX-VISM-8T1

VISM-8T1

2.0.(1)

1.5.05

MGX-VISM-8E1

VISM-8E1

2.0.(1)

1.5.05

MGX-RPM-128M/B

RPM

12.1(5.3)T_XT

12.1(5.3)T_XT

MGX-RPM-PR

 

12.1(5.3)T_XT

12.1(5.3)T_XT

CWM

 

10.4

10.4

MGX 8850 1.1.3x Firmware Compatibility

PCB Description  CW2000 Name  Latest F/W  Min F/W 

PXM1

PXM-1

1.1.32

1.1.32

PXM1-2-T3E3

PXM1-2T3E3

1.1.32

1.1.32

PXM1-4-155

PXM1-4OC3

1.1.32

1.1.32

PXM1-1-622

PXM1-OC12

1.1.32

1.1.32

MGX-SRM-3T3/B

SRM-3T3

n/a

n/a

MGX-SRM-3T3/C

SRM-3T3

n/a

n/a

AX-CESM-8E1

CESM-8E1

10.0.21

10.0.21

AX-CESM-8T1

CESM-8T1

10.0.21

10.0.21

MGX-AUSM-8E1/B

AUSMB-8E1

10.0.21

10.0.21

MGX-AUSM-8T1/B

AUSMB-8T1

10.0.21

10.0.21

MGX-CESM-T3

CESM-T3

10.0.21

10.0.21

MGX-CESM-E3

CESM-E3

10.0.21

10.0.21

AX-FRSM-8E1/E1-C

FRSM-8E1

10.0.21

10.0.21

AX-FRSM-8T1/T1-C

FRSM-8T1

10.0.21

10.0.21

MGX-FRSM-HS2

FRSM-HS2

10.0.22

10.0.22

MGX-FRSM-2CT3

FRSM-2CT3

10.0.22

10.0.22

MGX-FRSM-2T3E3

FRSM-2T3

10.0.22

10.0.22

MGX-FRSM-2T3E3

FRSM-2E3

10.0.22

10.0.22

MGX-FRSM-HS1/B

FRSM-HS1/B

10.0.21

10.0.21

MGX-VISM-8T1

VISM-8T1

2.0.(1)

1.5.05

MGX-VISM-8E1

VISM-8E1

2.0.(1)

1.5.05

MGX-RPM-128M/B

RPM

12.1(5.3)T_XT

12.1(5.3)T_XT

MGX-RPM-PR

 

12.1(5.3)T_XT

12.1(5.3)T_XT

CWM

 

10.4

10.4

BPX 8600 Hardware Compatibility

Card Type  Part Numbers  Latest H/W  Min. H/W 
Controller Cards

 

 

 

BPX-BCC-32M (Non-Orderable)

73-213840-00

P

A

BPX-BCC-64M (Non-Orderable)

800-04008-04

A

A

BPX-BCC-BC (Non-Orderable)

73-211380-00

D

A

BPX-BCC-3-32M (Non-Orderable)

800-04004-04

R

J

BPX-BCC-3-64M

73-3720-02

R

J

BCC-3BC

800-02916-01

E

A

BPX-BCC4V

800-03580-06

E

C

BPX-BCC4V/B

800-06483-02

C

A

Alarm Group

 

 

 

BPX-ASM

800-04009-01

C

A

BPX-ASM-BC

73-211910-00

C

A

ASM-LM

800-211910-10

B

A

BroadBand Switch Group

 

 

 

BPX-BXM-T3-8

800-02777-07

H

A

BPX-BXM-E3-8

800-02779-07

H

A

BPX-BXM-T3-12

800-02776-07

H

A

BPX-BXM-E3-12

800-02778-07

H

A

BPX-T3/E3-BC

73-2759-02

A

A

 

 

 

 

BPX-BXM-155-8

800-02664-07

H

B (C for APS)

BPX-MMF-155-8-BC

800-03255-01

B

A

BPX-SMF-155-8-BC

800-03257-01

B

A

BPX-SMFLR-155-8-BC

800-02593-02

B

A

BPX-BXM-155-4

800-02666-07

H

B (C for APS)

BPX-MMF-155-4-BC

800-03256-01

B

A

BPX-SMF-155-4-BC

800-03258-01

B

A

BPX-SMFLR-155-4-BC

800-02594-02

B

A

 

 

 

 

BPX-BXM-622

800-02646-10

L

D (E for APS)

BPX-BXM-622-2

800-02638-10

L

D (E for APS)

BPX-622-2-BC

73-2884-01

D

A

BPX-SMF-622-BC

800-03249-01

C

A

BPX-SMF-622-2-BC

800-03251-01

C

A

BPX-SMFLR-622-BC

800-03250-01

C

A

BPX-SMFLR-622-2-BC

800-03252-01

D

A

BPX-XLR-622

800-02738-01

C

A

BPX-XLR-622-2

800-02739-01

C

A

 

 

 

 

BPX-BME

800-02855-04

B

A

BPX-BME-OC12

73-2469-07

F

A

BPX-BXM-E-T3-8E

800-03933-02

A

A

BPX-BXM-E-E3-8E

800-03928-02

A

A

BPX-BXM-E-T3-12E

800-03931-02

A

A

BPX-BXM-E-E3-12E

800-03929-02

A

A

BPX-BXM-E-T3-12EX

800-03934-02

A

A

BPX-BXM-E-E3-12EX

800-03930-02

A

A

BPX-BXM-E-155-4D

800-03094-02

A

A

BPX-BXM-E-155-4DX

800-03093-02

A

A

BPX-BXM-E-155-8D

800-03092-02

A

A

BPX-BXM-E-155-8DX

800-03091-02

A

A

BPX-BXM-E-622-DX

800-03151-02

A

A

BPX-BXM-E-622-2D

800-03150-02

A

A

BPX-BXM-E-622-2DX

800-03149-02

A

A

 

 

 

 

RDNT-SMF-155-4R

800-03677-01

J

A

RDNT-SMF-155-8R

800-03679-01

K

A

RDNT-LR-155-8R

800-03678-01

J

A

RDNT-LR-622-2R

800-03676-01

F

A

RDNT-SMF-622R

800-03675-01

F

A

RDNT-SMF-622-2R

800-03674-01

J

A

BPX-T3/E3

800-03058-02

E

A

BPX-E3-BC

73-213070-01

E

A

BPX-MMF-2-BC

73-214290-00

D

A

BPX-SMF-2-BC

73-216270-00

D

A

BPX-SMFLR-2-BC

73-216270-01

D

A

 

 

 

 

BPX-STM1-EL-4

800-03716-02

A

A

 

 

 

 

BNI-3-T3/C

800-02858-02

A

A

BNI-3-E3/C

800-02859-02

A

A

SMF-LM-OC3

800-216270-10

C

A

SMF-LM-OC3-LR

800-216270-11

C

A

MMF-LM-OC3

800-214290-10

B

A

LM-3T3

800-213070-10

D

A

LM-3E3

800-213070-11

D

A

IGX 8400 Hardware Compatibility

Card Type  Part Numbers  Latest H/W  Min. H/W  * Note Below 
Controller Cards

 

 

 

 

IGX-NPM-32

73-2894-01

W

A

 

IGX-NPM-64

73-2895-01

W

A

 

IGX-NPM-32B

73-2554-04

L

A

 

IGX-NPM-64B

73-2363-02

C

A

 

IGX-SCM

73-3341-01

Y

A

Revision X or later for nodes with UXM IMA trunks

Alarm Group

 

 

 

 

IGX-ARM

73-218230-00

B

A

 

BC-512011

73-212360-00

D

A

 

Trunk Group

 

 

 

 

IGX-NTM

73-2296-04

E

A

 

BC-6271A-TI

73-207380-00

M

A

 

BC-6171A-E1

73-207370-01

P

A

 

BC-6083A-SR

73-208540-00

J

A

 

BC-550150-Y1

73-210820-01

D

A

 

IGX-BTM/B

73-3005-02

B

A*

"*Show AIT H/W Rev, BTM(B)=AIT+ACM1"

ACM1

73-2921-03

W

A

 

BC-571110A-T3

73-2879-01

L

A

 

BC-571210A-E3

73-2679-01

K

A

 

BC-571310A-E2

73-215940-00

D

A

AIT BC HSSI/E2

BC-571410A-HSSI

73-216370-00

A

A

AIT GIM HSSI

IGX-ALM/A

73-2558-03

J

A

 

IGX-ALM/B

73-2558-03

J

A

 

BC-UAI-1T3

73-217040-00

C

A

 

BC-UAI-1E3

73-2986-01

E

A

 

IGX-UXM

73-2511-03

D

A

 

BC-UAI-4-155-SMF

73-2703-03

D

A

 

BC-UAI-4-155-MMF

73-2705-03

D

A

 

BC-UAI-2-155-SMF

73-2699-03

C

A

 

BC-UAI-6-T3

73-2952-02

A

A

 

BC-UAI-3-T3

73-2954-02

A

A

 

BC-UAI-6-E3

73-2953-02

A

A

 

BC-UAI-3-E3

73-2955-02

A

A

 

BC-UAI-8-E1-BNC

73-2932-02

C

A

 

BC-UAI-4-E1-BNC

73-3061-01

C

A

 

BC-UAI-8-T1-DB15

73-2941-02

C

A

 

BC-UAI-8-E1-DB15

73-2942-02

C

A

 

BC-UAI-4-T1-DB15

73-3059-01

C

A

 

BC-UAI-4-E1-DB15

73-3060-01

C

A

 

BC-UAI-4-STM1E

73-3364-02

A

A

 

Port Group

 

 

 

 

IGX-FTM

73-2519-01

M*

A*

"*Show FTC H/W Rev, FTM=FTC+ACM1A"

ACM1A

73-2930-03

W

A

 

BC-6351A-V35

73-213240-00

E

A

FPC-V.35

BC-6352A-T1

73-213420-00

C

A

FPC-T1

BC-6353A-E1

73-213410-00

B

A

FPC-E1

BC-6354A-X21

73-214120-00

C

A

FPC-X21

IGX-HDM

73-2853-02

H

F

"*Show SDP H/W Rev, HDM=SDP+ACM2"

ACM2

73-2922-03

T

A

 

BC-5082A-V35

73-2450-01

K

A

 

BC-5083A-RS449

73-204850-00

V

A

 

BC-5084B-RS232

73-2723-01

W

A

 

IGX-LDM

73-207250-00

K

A

"*Show LDP H/W Rev, LDM=LDP+ACM1A"

BC-5286A-RS232

73-207180-01

L

A

LDI-4RS232

BC-5287A-RS232

73-207180-00

L

A

LDI-8RS232

IGX-CVM-DSOA

73-3002-02

D

A*

"*Show CDP H/W Rev, CVM=CDP+ACM1A"

IGX-CVM-T1EC

73-3003-03

E

A*

"*Show CDP H/W Rev, CVM=CDP+ACM1A"

IGX-CVM-E1EC

73-209660-00

H*

A*

"*Show CDP H/W Rev, CVM=CDP+ACM1A"

BC-6271A-TI

73-207380-00

M

A

 

BC-6171A-E1

73-207370-01

P

A

 

BC-550100-J1

73-210820-00

C

A

 

IGX-FRM

73-2517-03

N

A

 

IGX-FRM-31

73-2517-03

N

A

 

IGX-FRM-2

73-2519-01

M*

A*

"*Show FRP H/W Rev, FRM-2=FRP+ACM1A"

BC-6251B-V35

73-3253-01

M

A

FRI-4V.35-2

BC-6254A-X21

73-211440-00

H

A

FRI-X.21

BC-6355A-X21

73-214120-01

C

A

FRI-2X21

 

 

 

 

 

IGX-UFM-4C

73-2531-05

N

A

 

IGX-UFM-8C

73-2531-05

N

A

 

BC-UFI-8T1-DB15

73-2444-02

D

A

 

BC-UFI-8E1-DB15

73-2445-02

D

A

 

BC-UFI-8E1-BNC

73-2449-02

D

A

 

IGX-UFM-U

73-2349-04

D

A

 

BC-UFI-12V35

73-2711-01

D

A

 

BC-UFI-12X21

73-2712-01

D

A

 

BC-UFI-4HSSI

73-2693-01

C

A

 

 

 

 

 

 

IGX-UVM

73-2361-04

K

A

 

BC-UVI-2E1EC

73-2420-01

B

A

 

BC-UVI-2T1EC

73-2373-01

C

A

 

BC-UVI-2J1EC

73-2374-01

A

A

 

Known Anomalies

The following is the list of known anomalies in this Switch Software delivery. Included with each is a brief discussion of the problem. A more in-depth discussion is available in the release note enclosure of the problem record in Bug Navigator.

Bug ID   Description 

CSCdk22430

Symptom:

Checksum word 15 of backplane nvram is not recalculated when words 0-14 are updated using cnfbpnv.

Conditions:

Observed with BPX 9.1.01.

Workaround:

None.

CSCdk45222

Symptom:

Software error 532 is logged.

Condition:

The VC pointer is not valid it is used.

Workaround:

None.

CSCdk48180

Symptom:

The bcc card is WDT reset and suddenly logs swerr52 .

Conditions:

WDT reset occurs for no particular trigger but it's rare.

Workaround:

None.

CSCdm01239

Symptom:

Feeder connections go into the A-bit failure when the hub it is connected to goes into flooded mode.

Conditions:

Happens intermittently.

Workaround:

None.

CSCdm22426

Symptom:

While using jobs to down or up the connection based on a job trigger, the job will fail if dspbob is executed while the control signal toggle.

Conditions:

Observed with IGX 8.2.56.

Workaround:

Retrigger the job after dspbob.

CSCdm60702

Symptom:

When a bus error occurs on a node, and a rebuild results, other nodes in the network will see the rebuilding node in the degraded state. This shows up as "UNDeg" in the dspnds screen. A log message will also appear on these other nodes indicating that the rebuilding node went unreachable due to degradation. The unreachability will recover automatically.

Conditions:

Only occurs if a node rebuilds due to a bus error, and degraded mode is enabled in cnfnodeparm. Will not occur if a node switches processors due to a bus error.

Workaround:

No workaround needed. No adverse effects.

CSCdm60707

Symptom:

Can take longer than expected to clear unreachability with a node that has rebuilt due to a bus error. Other nodes in the network will declare the node unreachable due to degradation ("UNDeg").

Conditions:

Only occurs if a node rebuilds due to a bus error, and if degraded mode is enabled in cnfnodeparm on that node.

Workaround:

None needed. Problem clears automatically.

CSCdp98648

Symptom:

Equipment MGR can not tell the different between BXM legacy or enhance version.

Workaround:

Log into the BPX node and do dspcd XX and determine from number of channel support. The enhanced version of the BXM card has 61K channels, and the BXM card has less than 61K channels.

CSCdr05291

Symptom:

switchIfService must be specified to delete feeder trunks, but not routing trunks.

Workaround:

Use the CLI commands to delete feeder trunks.

CSCdr25273

Symptom:

Switch software does not report an alarm as expected when AIS-Line alarm is generated on a SONET line.

Conditions:

Using test equipment during compliance testing, an AIS Line alarm is generated. The expected result is to see an AIS Line alarm on the line, have StrataView/CWM report an AIS-L alarm, see the AIS statistic incremented

Workaround:

None.

CSCdr25275

Symptom:

An RFI-Line alarm is not shown on switch software as expected when an RDI-L alarm is generated on a SONET line.

Conditions:

Using test equipment during compliance testing, an RDI Line alarm is generated on a line. The expected result is to see an RFI-L alarm on StrataView/CWM and have dsplns show an RFI-L alarm on the line being tested

Workaround:

None.

CSCdr25281

Symptom:

When an RDI-Path alarm is generated on a SONET line, switch software does not produce the expected result.

Conditions:

Using test equipment during compliance testing, an RDI-Path alarm is generated for 2 +/- 0.5 seconds on a line. The expected result is that StrataView/CWM would report an RFI-P alarm condition and the dsplns command would show an RFI-P alarm on the line

In a second test, RDI-Line was generated continuously on a SONET line. The expected results are that StrataView/CWM would report an RFI-P alarm condition and the dsplns command would show a RFI-P alarm on the line.

Workaround:

None.

CSCdr33931

Symptom:

Neither dsplog (has no record) nor CWM (receive a trap) when APS active line in Yellow alarm.

Conditions:

When APS line in yellow expected to shown in dsplog as well as trap in CWM. Introduced because of 9.2.32 fix MR 000253 (CSCdr26613) where the trunk status is set to clear if the active line is Yellow and the standby line is OK. Use dsptrks command to show the active line status and trigger trap, unless a clean and easy path to send trap without setting the trunk to the Yellow alarm status can be found.

Workaround:

Use the dspapsln command to monitor APS line status but do not reroute connections.

CSCdr45021

Symptom:

SCT 1 is the default SCT reserved for MPLS. When an SES trunk is provisioned and if the default SCT is not changed to SCT 3, the trunk will fail to come up.

Conditions:

A warning message on the configuration screen indicates that the default is SCT 1 for MPLS and should be changed to SCT 3 for SES will be useful.

Workaround:

Check that SES uplink uses SCT 3 as service template class.

CSCdr52621

Symptom:

Enabling channel statistics drops the idle time on the node to an unacceptable level.

Conditions:

Occurs when many channel statistics are enabled and/or many connections exist on the node.

Workaround:

None.

CSCdr75042

Symptom:

The remote end of FRSM to FRSM endcount the FECN when enable the NNI with FCES option

Conditions:

test set --> kiwica71 11.3.1.31 (chan 227) <--> kiwica82 11.7.12.31(BNI) <--> NNI <--> kiwica81 11.8.12.31(BNI) <-- >kiwica71 11.4.1.31 (chan 229) (loopback)

Workaround:

None.

CSCdr89767

Symptom:

Software error 945 logs continuously.

Conditions:

Ongoing failure with normal network conditions

Workaround:

None. Note that reconfiguration of nwip and lanip did not help

CSCds20977

Symptom:

Signal Degrade cleared in internal BXM states, but SWSW still shows Signal Degrade.

Conditions:

Switch software release prior to 9.2.34, and SD condition cleared from line.

Workaround:

Upgrade software to at least Release 9.2.34

Further Problem Description:

The problem exists because older switch software does not know how to interpret the "Clear SD" message coming from the new firmware. So, the firmware and SWSW states get out of synch.

CSCds21195

Symptom:

The node becomes unavailable at the U/I. Several cards removed and reinserted themselves. Software error 112 logs repeatedly.

Workaround:

Identify the faulty card using the information in the SWLOG Assistant, remove it from the node and replace it.

CSCds33823

Symptom:

After upgrading switch software from 9.1.08 to 9.2.34, 4.8 kbps connections on LDMs may fail if using DFM.

Conditions:

The failed connections are seen immediately after upgrading the switch software. It appears to happen only for connections where one endpoint is 9.1.08 and the other is 9.2.34.

Workaround:

Change the speed setting of the failed connections, or to disable DFM.

Further Problem Description:

After the connections have failed due to too many routing attempts, issue the command rrtcon <connection_id>. Afterwards, issue rrtinf. At the bottom of the screen, you will see: Reason: Rsp - inconsistent lu at endpts

CSCds34151

Symptom:

There is no specific ALARMS when node in alarm such as LOC, LOC AIS-P PATH-RDI ALL we see is 'Line A lam Type OTHER'

Conditions:

CWM (Rel.92.08), BPX (9.2.23), BXM(MFB),OC-3

1) Connect the HP tester to the BXM OC3 port and the run CWM to manage this BPX node 2) Upline and port on the BXM card 3) At HP tester generate LOP or AIS-P or PATH RDI or LOC and verify the alarm was reporting on BPX 4) At the CWM, a) launch Equipment manager, b) select BPX node c) select BXM port and right click on the selected port d) and choose 'configure' then the popup 5 At the Line configure GUI, click 'BPX PhysicalLineconfigure' select 'BPX: SONET LineConfigure'

Workaround:

None.

CSCds57049

Symptom:

Card in active-F status when 2 or more lines of the card are in major alarm.

Conditions:

2 or more lines in major alarm

Workaround:

Issue the command: resetcd [slot] f. This will only clear the status until the next time the card falls into the above conditions.

CSCds84776

Symptom:

APS is configured as 1:1. Everything works fine at the physical layer. But the switch software is not receiving update messages from the BXM firmware. The firmware reports the working and protect lines are clear but the software shows the Alarm status is in "SigDegrade BER" state. Card error on bpx04 card 13 is also generated (see description below)

Conditions:

Most of the configurable elements such as the number of connections or trunks are loaded at the switch limit. This is independent of the switch limit.

Workaround:

Down the line and then up the line. The SigDegrade alarm should clear.

CSCdt07203

Symptom:

The hitless rebuild log fills due to repeated failed switchccs.

Conditions:

A bad standby BCC is required. The node must be running at least 9.2.

Workaround:

Clear the hitless log with the command dsphitless c or switchcc less often so that the hitless rebuild log tried get a chance to age out of the log.

CSCdt26312

Symptom:

Node experiences a software error 52, watchdog abort, resulting in a BCC switchover. The software error 52 will have a data field of 23 hexadecimal. Feeders connected to the BPX will declare LMI failure on the feeder trunk and condition their connections.

Conditions:

Seen in Release 9.1 and 9.2 baseline software on the BPX. Occurs on nodes with multiple feeders that are using nwip for IP traffic to the feeders.

Workaround:

Set the watchdog timeout of the ILMI process to 40 seconds so that the switchover will occur prior to the LMI failure/connection conditioning on the feeders. Use cnfprf P ILMI E 40 to set the watchdog timer for the ILMI process, use dsperr t to verify the setting. Use an out of band solution rather than nwip for IP traffic to the feeders as this appears to be a condition of the problem.

CSCdt42261

Symptom:

After introducing errors on an aps 1+1 line, the line will switch as designed. However, the errors are recorded on the now active line and not the standby line.

Workaround:

None.

CSCdt42261

Symptom:

After introducing errors on an aps 1+1 line the line will switch as designed. However, the errors are recorded on the now active line and not the standby line.

Workaround:

None.

Known Anomalies from Previous Releases

The following is the list of known anomalies in previous Switch Software deliveries. Included with each is a brief description of the problem. A more in depth description is available in the release note enclosure of the problem record in Bug Navigator.

Bug ID  Disposition of Anomaly 

CSCdp57264

There is a fundamental design issue which needs to be thoroughly reviewed before fixing the problem. The bug is in the 'W' state until this problem can be resolved.

CSCdr21149

This bug is in the 'I' state. It could not be reproduced and more testing and information is required before closing the anomaly.

CSCdr25253

Closed. Fixed in Release 9.2.37.

CSCdr41957

Closed. Duplicate of CSCdr15924, which was fixed in Release 9.2.34.

CSCdr47848

Closed. Unreproducible.

CSCdr48000

Closed. This is not a bug due to the UXM complexity.

CSCdr50690

This bug is in the 'I' state. More information is required from the submitter before closing the anomaly.

CSCdr64541

Closed. Fixed in Release 9.2.37.

CSCds18089

Closed. Fixed in Release 9.2.37.

CSCds50019

Duplicate of CSCds82052, which was fixed in Release 9.2.37.

CSCds66861

Closed. Fixed in Release 9.2.37.

CSCds90571

This bug is in the 'I' state. More information is required from the submitter before closing the anomaly.


Note   These anomalies were closed because they were internally found (and not customer-found). Also, in most cases, they either require significant effort to resolve, are unreproducible, or have a benign effect on the system.

Problems Fixed in Release 9.2.37

Following is the list of fixed problems in the 9.2.37 Switch Software release. Included with each is a brief discussion of the problem.

Bug ID  Description 

CSCdk48068

Symptom:

Unable to copy UVM firmware DCA or DDA or DEC from one node to another over a trunk. Node says firmware is unavailable.

Conditions:

Observed with IGX Release 9.1.03.

Workaround:

Attach modem to node that needs DCA or DDA or DEC firmware for the UVM and download it via SV Lite. If there is a SV+ station in the network and all nodes are pingable from the SV+ with IP-relay, than tftp the firmwareimage from SV+ station to any nodes in the network.

CSCdk62907

Symptom:

Telnet access is not disabled on BPX/IPX/IGX using off2.

Conditions:

off2 18 does not work in disabling telnet access.

Workaround:

None.

CSCdp34465

Symptom:

dspcd displays BME-622-622 instead of BME-622.

Conditions:

Observed with BPX 9.1.15.

Workaround:

None. This is a cosmetic issue and does not adversely affect the node.

CSCdr17998

Problem:

UBR connections terminating at ASI-OC3 endpoints log software error 9082 when CLP is enabled or when CLP is disabled and PCR < 10 cps. Other connection types terminating at ASI-OC3 endpoints log software error 9082 when SCR < 10 cps.

Solution:

In function usr_to_int_bw(), ensure that software does not send rates less than 11 cps to the ASI-OC3 card. This solution supersedes the fix described in CSCdp51531.

Detailed Problem Description:

A previous fix removed the ASI OC3 discrete value rounding done when converting user bandwidth parameters to internal (i.e. card) bandwidth parameters. The parameter conversion is done in function usr_to_int_bw(). The fix worked as long as the user entered data rates were >= 10 cps. The PCR < 50 cps project uncovered this limitation.

To fix the problem, the user bandwidth parameters are checked to verify that they are not less than 11 cps, which is the lowest supported discrete rate value for the ASI OC3 card. If the user entered parameter is less than 11 cps, software will send 11 cps to the ASI OC3 card. The 11 cps limit checking only applies to the ASI OC3 card, and will not affect the performance of other card types

CSCdr20915

Symptom:

User attempted to cancel the resetcd command by entering "bye" at the reset type prompt and it reset the card using the arbiter option.

Conditions:

Observed in BPX 8.4.22.

Workaround:

Use the delete key to cancel the command.

CSCdr25253

Symptom:

The AIS-Path alarm is not seen on a SONET line when an Path AIS is sent to it.

Conditions:

Using test equipment during compliance testing, an AIS-Path alarm is generated. The expected result is to 1. See AIS-P reported on StrataView/CWM 2. See the AIS-P statistic incremented 3. See the line in Major AIS-P alarm

Workaround:

None.

CSCdr25273

Symptom:

Switch software does not report an alarm when AIS-Line alarm is generated on a SONET line.

Conditions:

Using test equipment during compliance testing, an AIS Line alarm is generated. The expected result is see an AIS Line alarm on the line, have StrataView/CWM report an AIS-L alarm, and see the AIS statistic incremented

Workaround:

None.

CSCdr25275

Symptom:

An RFI-Line alarm does not occur when an RDI-L alarm is generated on a SONET line.

Conditions:

Using test equipment during compliance testing, an RDI Line alarm is generated on a line. The expected result is to see an RFI-L alarm on StrataView/CWM and for dsplns to show an RFI-L alarm on the line being tested

Workaround:

None.

CSCdr51769

Symptom:

dspqbinstats shows negative values

Conditions:

When dspqbinstats overflows a certain value, the values show negative. This does not mean that there are drops or that the queue is overflowing.

Workaround:

Resetting the card clears the statistics temporarily.

CSCdr57396

Symptom:

This problem was found during code review. The possible effect of this bug is (1) the VC Q depth value may not be changed as desired and/or (2) possible abort on the node.

Conditions:

This applies only if the cnfcon command is being used on a local connection with both ends of the connection terminating on the same slot.port.

Workaround:

Do not execute cnfcon for a local connection when both endpoints of the connection are being terminated on the same slot.port. Instead, delete the connection; readd the connection and make sure to specify the required VC Q depth value during the addcon command.

CSCdr64541

Symptom:

dspcntrstats displays negative values for large real-time counters. Counter Cbrctxl has a negative value.

Conditions:

Observed on BPX with large values for real-time counters.

Workaround:

None.

CSCds15146

Symptom:

Incorrect information is being displayed when the output display is cancelled on the dspclksrcs command. While looking closely, the output that is displayed is the first clock screen over the top of the currently displayed clockscreen. redscrn will not fix.

Conditions:

Pressing cancel during the clock source display listing after the first screen.

Workaround:

None.

CSCds16812

Symptom:

When a cbr/ubr/vbr connection is programmed, the channel programming value sent to the trunk card are not correct.

Conditions:

This only happens with an asymmetrical load.

Workaround:

None.

CSCds18089

Symptom:

BPX cnfapsln displays "Signal Detect" instead of "Signal Degrade".

Conditions:

Configuring APS on BPX with cnfapsln.

Workaround:

None.

CSCds24390

Symptom:

con_verify debug command is not supported in 9.2 and higher releases.

Conditions:

All 9.2 and 9.3 Releases.

Workaround:

None.

CSCds47570

Symptom:

Through SNMP, not able to set SCR to be 6 cps.

Condition:

This is due to an invalid atmEndptSCR and atmEndptOeSCR range 7 - 1412830 specified in switch.m. it should be 6 - 1412830

Workaround:

Use CLI commands cnfcon or addcon or cnfcls if SCR has to be configured to be 6 cps.

CSCds52967

Symptom:

Secondary clock sources are hidden when a thirty fourth primary source is added to the network.

Conditions:

Addition of a new primary clock brought the amount in the network to thirty four. When dspclksrcs is issued all secondary clocks are hidden. Under secondary none is displayed. Switch Software Release IGX/BPX 9.1.19-9.1.22

Workaround:

Have less than thirty four primary clock sources configured at one time in order for the secondary clocks to be displayed correctly. This is a display problem only, the secondary clocks are still configured.

CSCds59200

Symptom:

Software error 378 logswhen issue the copycons command from the T1-IMA trunk card to the UXM-T3 card which is in standby status (no configuration on it) on IGX feeder node.

Condition:

Copycons fails as expected. But if copycons from the same UXM-T3 card to the T1-IMA trunk card, this swlog does not show up, the system gives a copycons failed message.

Workaround:

None.

CSCds61240

Symptoms:

When adding connections on a BPX node, "Unknown Response (17)" is displayed. This occurs while adding AUSM to AUSM connections.

Conditions:

On the remote end, 1) Sum of minutes is exceeding the port speed. 2) Total number of connections are exceeding the number of connections that are allowed for the configured polling rate. BPX nodes running Release 9.3.10 MGX PXM firmware running 1.1.31 AUSM running 10.0.20.

Workaround:

Change the pooling rate to 10 minutes which allows up to 8000 connections by using cnfsysparm command.

CSCds64587

Symptom:

copycons allows atfx connections to be added on FRM card which does not support atfx connections.

Conditions:

Observed on IGX. addcon cannot add atfx connections to FRM card while copycons can.

Workaround:

None.

CSCds66268

Symptom:

copycons does not generate a valid warning message.

Condition:

Switch Software Release 9.2.35 executing copycons with template connection having parameters set to generate a warning message. (like high PCR is set for an ATFR connection between UXM and FRM on IGX)

Workaround:

None.

CSCds66861

Symptom:

Connections stop routing across a UXM trunk when the configured gateway connection limit is reached. By increasing the number of gateway connections supported on the trunk you can only route further connections until the gateway connection limit is once again reached. Then no further via connections will route and they report the failure as unable to find route. There is sufficient bandwidth and conid's to support the remaining failed connections.

Conditions:

UXM trunk card with CGW and SGW connections preferred routed across it. Found in SWSW 9.1.19 and UXM BBJ on E3 trunk cards.

Workaround:

1.Down one of the connections that is a gateway connection on the trunk that has reached its limit for gateway connections.

2.Wait for all the failed connections to reroute and come to normal status.Add new via connections if required.

3.Up the connection that was downed in the first step.

CSCds69729

Symptom:

The following symptoms are all related to this defect:

On IGX, tstconseg performs the entire number of iterations when the abort flag option is SET and the test fails.

On BPX, the default value for the abort flag is "NOT to abort" but tstconseg stops at first encounter of failure when the abort flag option is not specified.

Conditions:

On IGX: The following conditions are needed for this problem to occur. 1) tstconseg is run on a connection with the abort flag option SET and Loop count > 1. 2) The test fails for the connection.

On BPX: The following conditions are needed for this problem to occur. 1) tstconseg is run on a connection with Loop count > 1 and the abort flag option is not specified. 2) The test fails for the connection.

Customer Impact:

1) On IGX, the test should abort after the first failure. Instead, it continues until for the entire count, blocking other commands and wasting CPU time. 2) On BPX, the test should continue after the first failure when the abort flag option is not specified. Instead, it stops and user may not know if the test will succeed on a retry.

Workaround:

Set loop count = 1. With SW Release 9.2.37, this is not fixed on BPX, tstconseg passed on DAX connections.

CSCds72447

Symptom:

Cost-based route recovery allows route to exceed connection cost cap.

Conditions:

Cost-based routing could not find a path for the connection. New route calculated exceeded the connection cost cap yet the connection routed. Observed in 9.1.24 and 9.2.35.

Workaround:

Possible workarounds include using cnfpref to specify a preferred route. This will provide a route for the connection. Cost-based routing can be disabled using cnfcmparm. Also, the trunk cost can be tuned with cnftrk. The connection cost cap can be configured with cnfrtcost.

CSCds75109

Symptom:

BPX upstats displays negative numbers intermittently.

Conditions:

Same as above.

Workaround:

Clear statistic counters with upstats clear.

CSCds75929

Symptom

dspctrlrs output is truncated, it does not display the header "Intfc Type", rather it just displays the header "Intfc" and truncates the "Name" of the feeder. dspctrlrs output in BPX does not wraparound if more than one screen of controllers are added. The CLI neither queries the user for displaying more output nor the display is clear.

Condition

This problem is seen only in BPX and the screen display is cluttered only when the number of controllers exceeds 12 to display more than one page.

Workaround

None. dspnode can help to identify the feeders and their type.

CSCds82339

Symptom:

When a graceful upgrade is done on an IGX node, the idle time of the node may be reduced to < 10% for a long time. The TRNS task takes > 50% of the CPU. After this period of time, the node functions normally.

Condition:

This happens only if there are ATFR connections on the IGX node with the FR side as the master end of the connection. The more ATFR connections with FR as the master on the node, the longer the TRNS process takes a lot of the CPU.

Workaround:

Do a cnfcon on all the ATFR connections with FR as the master end-point and modify at least one of the BW parameters.

Further Problem Description:

This problem happens because of a inconsistency between the BW parameters of the ATFR connections stored on the ATM side (can be IGX or BPX) and the FR side. This discrepancy arises only if the connection is added from the IGX node (on the FR side). When doing swithcc/upgrade, the master node will send BW updates of all its connections to all the slave nodes. If the slave node detects any discrepancy, it will respond back with a BW Change request. If there are large number of connections with this discrepancy, a BW change request is generated by the slave node for each of those connections - and these messages are processes by the TRNS task on the master node, thus utilizing many CPU cycles.

CSCds84556

Symptom:

An "L" is displayed in the IGX dsppwr screen in the status field.

Conditions:

Observed on IGX with DC power and the power supply is in "OK" state.

Workaround:

Ignore the "L", it has no meaning.

CSCds86393

Symptom

cderrors record wraparound function does not work in IGX and BPX.

Condition

This occurs when the cderrors record wraparound function is enabled using cnffunc.

Workaround

None.

CSCds88748

Symptom:

After upgrade, the software does not indicate UXM card LCN resync capability even if the card has this capability.

Conditions:

The problem only happens when the firmware is upgraded first. If the software is upgraded first and firmware upgraded later, this does not happen.

Workaround:

dncd/upcd fixes the problem.

CSCds89338

Symptom:

dspload shows negative load when a prefer path connection is routed.

Conditions:

The load for vbr/abr has to be asymmetrical. A connection with asymmetric load say ms/sm. If the trunk does not have enough ms trunk bandwidth but enough sm bandwidth, the connection still routed. But the ms direction in the dspload shows negative load.

Workaround:

None.

CSCdt01430

Symptom:

NWIP traffic is not delivered, other CC traffic is delivered as expected

Conditions:

The logical trunk number of a feeder equals the slot number of a BXM virtual trunk and CC traffic is using the virtual trunk. While Y redundancy is not a condition of the problem, if the virtual trunk is Y redundant both physical slots of the Y redundant pair must be evaluated for the stated condition. The problem is specific to BXM virtual trunks.

Workaround:

1. Do not use virtual trunks or if you do, restrict CC traffic on all virtual trunks that meet the condition of the problem.

2. Use wraparound virtual trunks. The BCC self-test must be disabled if on a release prior to 9.2.34 as CSCds62320(duplicate of CSCdp46785) will cause loss of traffic on wraparound virtual trunks.

3. Make sure that there is no feeder with a logical trunk number that is equal to the slot number of any virtual trunk. This requires moving the feeder trunk or the virtual trunk(s) if the problem already exists on the node.

CSCdt04146

Symptom:

BPX logs software error 923 during copycons command.

Conditions:

copycons with starting channel endpoints at virtual trunks (invalid endpoints). Observed in BPX 9.2.34.

Workaround:

Avoid copying connections with invalid endpoints.

CSCdt04849

Symptom:

Memory corruption may occur as the software image downloads while the firmware image downloading is in progress through TFTP.

Condition:

This occurs only while downloading the software image while firmware image download is in progress.

Workaround:

Download the software image after finishing the firmware image download.

CSCdt04852

Symptom:

1. CWM does not recognize back card removal on IGX and BPX nodes for cards in active state.

2. Feeder object counter is incremented on dspsvmsg display, whenever an active card object robust message is sent.

3. Deactivating an active empty card in IGX does not remove card info in CWM display.

4. When a secondary y-red card is removed or y-red is deleted notify CWM about the secondary card status too.

Condition:

Problem "1" occurs for active cards only.

Workaround:

None.

CSCdt15193

Symptom:

Node aborts with a software error and abort error of 3000000 after issuing the rsh command.

Conditions:

This is a very rare, defect, never actually observed, but discovered during a code inspection. If the node has nearly all of its memory allocated, or the memory regions are extremely fragmented then it is possible that invoking the rsh command would cause the node to abort.

Workaround:

To be sure that enough memory is available, invoke the command dspprf r t and validate that the combined delta between the columns "Blocks" and "Allcd" for DYNM, STTC, POOL, HIT1, PL02 and HIT2 are at least 100 and that dspmemblk shows that the "maximum block in bytes" for DYNM, STTC, POOL, HIT1, PL02 or HIT2 is 4k or larger (only one needs to be 4k or larger).

CSCdt24344

Symptom:

BPX command srstats shows field "Stby Bus Errors" continuously incrementing.

Conditions:

Observed on BPX 9.2.33 on a BCC4 node without a standby BCC.

Workaround:

Ignore srstats "Stby Bus Errors" if standby BCC is not in standby state and not mismatched.

CSCdt24454

Symptom:

When a card fails in a node running 9.2.XX software, the alarm is logged in the alarm logs but there is no Minor Alarm seen in the bottom right hand corner. This should occur if there are no previous alarms in the node.

Workaround:

None.

CSCdt35981

Symptom:

UXM card fails the loopback test.

Condition:

A disconnected cable on a UXM OC-3 trunk card or line card or an LOS condition due to intermittent physical line failure.

Workaround:

Enter resetcd XX f to clear the problem, or disable the loopback test by using the command cnffunc 1 d.

CSCdt37502

Symptom:

FTM connections are auto deleted on the master side (UVM/CVM side) when a switchcc is performed.

Conditions:

IGX with Switch Software Release 9.2.34/36 FTM-UVM/CVM connections after one/two switchcc

Workaround:

None.

CSCdt49018

Symptom:

An 1M3 abort occurs on IGX (or HW watchdog time-out on older 32M NPMs) after changing the node number from 39 to any other number.

Conditions:

Using rnmnd to change a node number from 39 to any other number while IGX is running Switch Software Release 9.2.20 or later.

Workaround:

Renumber the node prior to adding it to the network. Under no circumstances should a node be renumbered from 39 to some other node number while an IGX with an affected SWSW release is in the network. Consequences include aborts and inconsistent databases, possibly resulting in the deletion of the renumbered node from the network.

Problems Fixed in Release 9.2.36

Following is the list of fixed problems in the 9.2.35 Switch Software release. Included with each is a brief discussion of the problem.

Bug ID  Description 

CSCdr82206

NPM in slot 2 may not be able to communicate with UXM

CSCds87060

Non-gateway LCN maybe assigned where gateway LCN is needed.

Problems Fixed in Release 9.2.35

Following is the list of fixed problems in the 9.2.35 Switch Software release. Included with each is a brief discussion of the problem.

Bug ID  Description 

CSCdk19709

BPX may sync a neighbor test in error and report a suspected BCC failure

CSCdm07982

ALM/B and NTM reset with hardware errors after UFM card fails

CSCdm12139

Packet_line table not updating Bursty_a_load, Bursty_b_load

CSCdm42912

SNMPProxyAgent fails on SET of PrefRoute with 10 hops (switch rejects)

CSCdm60699

Async updates are sent incorrectly when VCQueue fills up.

CSCdp51531

Software log 21(9082) occurs when UBR con added and one of the endpoints is ASI-155

CSCdp53419

UXM trunk LCN verification not performed on card configuration

CSCdp56458

Software error 34 occurs when entering a three-part ASI address for many different UI commands

CSCdp73084

upport, dnport, cnfport do not show port speed due to screen overwrite

CSCdr03517

Info Bus A Reports 1 Error(s) (CNTL) logged frequently with LCC LDM FW

CSCdr53669

SLT:ILMI is not disabled after changing virtual trunk to line port.

CSCdr55450

Flood of swlog 992 kills ILMI task on BCC making all AXISs unreachable

CSCdr58956

10 hop connection only adds in one direction with cost-based routing

CSCdr65152

MIB variables not incrementing for fpTrkStatsEntry variables

CSCdr68507

dsplog shows wrong VPI/VCI when port loopback deleted

CSCdr70919

Interface Shelf Major alarm logged when changing protocol to run on BXM card

CSCdr71482

dsptrkstats tx and rx load percentage incorrect, sometimes greater than 100%

CSCdr71781

Auto Memory reserved is not set to zero (swerr 3000) after upln on BXM-E

CSCdr72296

snmp walk on shelfslotinfotable causes swerr 26 when UXM is missing a back card

CSCdr73183

111 when 23 ifcs (trk/prt) on a BXM slot, 23+ causes trunk/port statistic loss

CSCdr73442

Deleting a simulated AAL5 feeder causes 1M3 abort and swerrs 513, 589 and 502

CSCdr74031

cnfcmb parameters changes on IGX when adding BPX to network

CSCdr74447

VC Depth does not get set to the correct value during addition of PVC

CSCdr74841

Display Routing Table Contents does not work

CSCdr74919

bnni lights do not go out after a dntrk

CSCdr75723

Software error 938 PNA_SEND_ERR when lan default gateway is set to zero.

CSCdr76988

Rounding problem in calculating UBU on dspbusbw

CSCdr78202

Software error 1120 logged during upgrading from 9.3.1T to 9.3.1V

CSCdr78391

Software error 3074 when upgrading from 931T to 931V

CSCdr78404

UVM has excessive delay for g729 conn which route on uxme 2Mbps virtual trunk

CSCdr79123

During routing delay of path may be calculated incorrectly

CSCdr79195

Too many connections could be packed by pack_conns()

CSCdr80522

Investigate user commands included HIPRI login for problem caused by Pause_proc

CSCdr80662

Some connection parameters are reset to default on rebuild/switchcc

CSCdr81947

dspselftst stopped working due to fragmented dynamic memory

CSCdr82470

Port loopback for the local slave end of a daxcon fails

CSCdr83296

VSI partition addition, dntrk or cnftrk on virtual trunk causes unreachability

CSCdr85197

The random() function is deterministic

CSCdr86188

AIS generates bit set for slave end of ATM daxcon with line in LOS

CSCdr86717

Mismatched back cards are allowed in a Y-red configuration

CSCdr91284

Two software errors 997s are logged after addtrk <vtrk>

CSCdr92045

Communication failure on trunks creates software error 1417.

CSCdr95419

delapsln executes without confirmation

CSCdr95576

Software error 327 with switchcc and failed connections

CSCdr95604

Allow IGX transmit rate to change locally for an added trunk.

CSCdr95788

Enhancement for signalling Qbin support

CSCdr96358

Last line of dsptech is writing into the border

CSCdr96513

The first interface upped on BXM/UXM has an incorrect maximum discard threshold.

CSCdr98681

cnftrk on BTM or ALM causes software error 923

CSCds00854

Software error 1427 is generated.

CSCds01587

Switch sending cells rx/tx statistics as 0 to CWM

CSCds02627

cnfqbin cannot use the default discard threshold .

CSCds02931

ILMI interval statistics are not collected .

CSCds03275

No trunk statistics are collected for last slot of IGX . Caused by CSCdm04491 fix

CSCds05668

Node goes into degraded mode after upgrading from 931Y to 931b

CSCds07761

SLT:Software error 103 UBU allocation errors

CSCds08777

Incorrect card/image accepted in tftp request. Missing Cmi_fwdl_prefix.

CSCds08808

Changing trunk rate using cnftrk overwrites BXM OC-12/T3/E3 with OC-3 Q depths

CSCds09778

BXM:CBR traffic drops as trunk Qbin bandwidth does not change with connection. reroute/dncon/upcon

CSCds12523

LMI Interval statistics are not collected.

CSCds13718

Incompatibility between Switch Software Release 9.2.23 and BXM firmware MF27.

CSCds16795

Incorrect programming of ingress/egress MCR on a terminating UXM trunk

CSCds17902

Software errors 532 & 538 found on BPX

CSCds22399

dspcon shows error of connection does not exist when dspcons shows all connections

CSCds22519

Software error 9082 logged for UXM when NPM resetcd

CSCds31978

Inconsistent via connections routed over UXM trunk once gateway connection limit is reached.

CSCds32831

dsptrkstats on down BNI card produces software log 8096

CSCds35608

UXM is not configurable to NON-CRC-4 mode.

CSCds36582

BCC Clock failure not processed by switch software during switchcc

CSCds39545

dspfdr does not display the VSI channels correctly.

CSCds43387

Software error 1128 on executing dspbuses when standby bus is failed

CSCds50411

delyred executes without confirmation

Problems Fixed in Release 9.2.34

Following is the list of fixed problems in the 9.2.34 Switch Software release. Included with each is a brief discussion of the problem.

Bug ID  Description 

CSCdk55887

dspport command moved from user-level-6 to user-level-2 in 8.1

CSCdm13655

VC bw parameter is not reused (initialized differently during upgrade vs provision)

CSCdp50091

data_channel table not updating with 9.1.15 switch software

CSCdp67775

BPX does not clear last user request after SF switch

CSCdp93955

Swlog 532 when doing a snmpwalk on the node

CSCdr08430

Non TS queue size not saved in bram; also strange queue size behavior

CSCdr09440

ASI Qbin config lost when programming 2ndary card in Y-Red set

CSCdr11698

TS cell discards on Virtual Trunks with overbooked f/relay traffic

CSCdr11823

BCC tstber channel could use VPI that is in the VSI range

CSCdr15924

Failure to receive proper traps w/ 2+ CWMs pointing to same network

CSCdr20925

Connection data stops when reverted to primary in Y-red

CSCdr21739

Node hung up and lost access after deleting trunk.

CSCdr22568

ILMI Disable Command not sent to BXM FW when ILMI is disabled on a port

CSCdr23432

Switch aborts when cnfport command is issued.

CSCdr25318

UFMU port reports active state when the back card is missing

CSCdr27853

cnfcmparm 9 (reroute timer) should be defaulted to 3 seconds

CSCdr32789

Gateway LCNs are not getting updated if the other end is BXM and cnfrsrc done at BXM

CSCdr33428

UXM number of channels mismatch after card rebuild

CSCdr36808

ORIONSLT:SPVC reroute failed due to cross commit fail but PXM, BXM have RSRC

CSCdr36819

Message 0x53 not sent when dntrk/deltrk is done on Egress/Ingress side

CSCdr38707

SLT: Total VSI min. bw > 1412830 should not be allowed on BPX.

CSCdr41814

Prevent AR/VSI conflicts for VPIs used by Feeders for LMI/IP - SNMP changes

CSCdr48340

dspnw on a nw with IMA virtual trunks causes swerr 1423 or 1M3

CSCdr49264

Add rt-vbr connection via CWM, CLI shows nrt-vbr and snmpget shows as rt-vbr

CSCdr49301

PVC does not route after preferred is not available

CSCdr51105

Software error 30 is logged while UXM is inserted

CSCdr56249

Transition counter stats (LOS,..) not updated when line goes into alarm

CSCdr58725

Selftests: Freq.value of < 40seconds causes consistent resetting of UXM cards

CSCdr64725

MIB variable switchIfOperStatus reports up when a trunk is actually added

CSCdr67236

SES have stats file 1 hour ahead of bpx stats file even time are same

CSCdr75146

Connections will not route due to lack of LCNs as seen in constats command

CSCdr79123

During routing delay of path may be calculated incorrectly

Problems Fixed in Release 9.2.33

Following is the list of fixed problems in the 9.2.33 Switch Software release. Included with each is a brief description of the problem.

Bug ID  Description 

CSCdj14920

Unable to clrcnf on BPX node whose number is > 63

CSCdm04491

Swerr 921 flooding

CSCdm13655

VC bw parm is not reused (initialized differently during upgrade vs provision).

CSCdm29466

Cannot addtrk on the VSI network because of VPC conid mismatch

CSCdm31518

"Active CC failure (EEPROM, SAR) and standby unlock or reseat causes rebuild."

CSCdm38578

Echo Negotiation for telnet between AIX and BPX

CSCdm48790

SIU phase errors from all BXM cards in a node

CSCdm69629

Different values of statistical reserve for dsptrkcnf and dspload

CSCdm88055

Job run job experienced failed

CSCdp20486

UXM IMA physical line alarms are not sent to SV+

CSCdp50871

UP/Down Line on ALM-A behaves erratically.

CSCdp53961

Control card mastership error not properly detected by software

CSCdp58131

SNMP get function in atmTrunkStatsTable

CSCdp62387

APS Clear Trap 20100 does not distinguish various types of clear events.

CSCdp68440

Swerr 961(BAD_LCN_SPECIFIED) found after dnport/dnln

CSCdp72012

Swerr 129 (BAD_TYPE_LOGGED) found at BPX2

CSCdp73065

Background Tst card errors on active. Card has state ACTIVE-F w/ss

CSCdp73606

Port LED remains on when line is downed on UXM.

CSCdp78731

LCN and VPC conid count is not sending correctly in TBL

CSCdp83180

Swerr 614 AUTO_DEL_LCON and 612 AUTO_DEL_VC upon fallback from 9.3.0L

CSCdp83902

UVM Line pass through does not work on the second physical line on UVM

CSCdp87624

Autodel trunk when rebuilding a port with 32 vtrks

CSCdp93368

When up a line then switch software seems to program all cons on that card

CSCdp93728

Summary statistics overflow is not detected correctly for Port and VI stats

CSCdp94039

Swlog 2000 occurs when snmpwalk on an IGX node

CSCdp95286

Cross point failures on the bcc.

CSCdp95807

Robust object message for vtrunks appears to be reporting wrong channel count

CSCdp96768

VSI and SVC bandwidth is not eliminated while configuring egress hpqbn b/w.

CSCdp98970

VT session timeouts on particular page when running dsprts

CSCdp99622

"Burn UXM/FW using C-bus, gets aborted"

CSCdp99780

Inhibit line loop diagnostics for IMA line/trunk

CSCdr00360

A Tstdelay command cannot run while card is initilized

CSCdr04828

IP relay channel is not getting deprogrammed when AAL/5 feeder is deleted

CSCdr06086

A dsp_pa_fail0 switch statement falls through when it should not.

CSCdr06280

Conditional update should not be integrated for a trunk between T1 and E1

CSCdr08084

A 62 message is not send on addyred if the secondary card is running self-test

CSCdr08231

A clrtrkstats does not clear Trunk Qbin statistics

CSCdr08952

A addloclp on BNI feeder connection aborts a node under certain circumstances

CSCdr10473

A swerr 1012 (BAD_RS_NCHANS) occurs after hitless rebuild

CSCdr11310

Configure LMI on UXM port causing swerr 987

CSCdr11823

A non-Fatal card error occurs on red. BXM during PXM1 upgrade. Refer to bug CSC46785

CSCdr11837

The maximum channel limit for dspchoid command is incorrect

CSCdr12300

Switch MIB is inconsistent with the CLI

CSCdr14544

PNNI VPI.VCI 0.18 is blocked when path 0 is built on BXM.

CSCdr14558

Switch software updates wrong port DB and robust message after Y-Red UFM switch over.

CSCdr14935

Unable to add UFM UXM connections from UFM side and there is corruption of Be Bc.

CSCdr17056

Provide UNKNOWN state for serialPortLeadState

CSCdr19348

NTS connections get bit errors when Frame Relay bursts fill up trunk capacity

CSCdr20760

Incorrect prompt while deleting a trunk on IGX UXM card

CSCdr21739

Node hung up and lost access after deleting a trunk.

CSCdr26582

CD error after issuing a addctclr command (SLT)

CSCdr30234

Available Conids gets updated only on the nodes connected by the trunk.

CSCdr32875

"int_all_usr_updt, trkchans: kicks of reroute only for trunks attached locally."

CSCdr41370

Dspchstat from Port counter slowly ramps-up to send rate

Problems Fixed in Release 9.2.32

Following is the list of fixed problems in the 9.2.32 Switch Software release. Included with each is a brief description of the problem.

Bug ID  Description 

CSCdk03916

Trunk information is inconsistent

CSCdr26613

"When active APS line has YEL, trunk fails."

CSCdr35085

Switchcc cannot be cancelled when updates pending

Problems Fixed in Release 9.2.31

Following is the list of fixed problems in the 9.2.31 Switch Software release. Included with each is a brief description of the problem.

Bug ID  Description 

CSCdk15523

"Integer overflow results in computation in get_bc, get_be funcs"

CSCdk22052

Switchcc event logged under trapd.log when the command is cancelled

CSCdk45354

No data continuity between UVM & HDM for nx64 connection

CSCdk60213

HDM data errors with 1152 kb/s connections on 9.1.06

CSCdm10213

After upgrade or switchcc in 9.1, extra connections may appear

CSCdm20593

Switch software should not allow an ATFR connection between two UXMs

CSCdm26083

Dsptrkbob causes swerr 30 and 923 when performed on sec Y-Red card

CSCdm46032

SNMP identifies ALM/A line as ATM trunk

CSCdm47765

VT cause memory leak

CSCdm68968

"VC-Q depth setting at default value, Connection Manager, IGX, routing and feeder node"

CSCdm75577

UFM-C to BXM SIW/NIW connection discards 100% cells at BXM on BPX if the connection is between UFM-C on IGX to BXM on BPX.

CSCdm77271

Incorrect modem upgrade support

CSCdm87788

Unable to add connection with maximum rate on BXM-T3 port with direct mapping

CSCdm91529

"Screen flicker on dspnds, with more than 2 columns nodes"

CSCdp07967

Statistics files updating standby cause standby to hang in update state

CSCdp09854

The value for maximum pvc bw in rsrc partition displays wrong value

CSCdp15350

SNMP GET-NEXT does not work for frLportStatTable

CSCdp20534

Uninitialized variable in get_rrt_space() function

CSCdp27598

Disabling and enabling echo canceller produces Channel Pair Problem

CSCdp32245

BXM-OC3 DX performance monitoring is not implemented Bellcore 253 Sec 6.2.2.

CSCdp32422

addlnlocrmtlp does not loop traffic properly in APS 1+1 cross over circuit

CSCdp32490

Secondary CC went from UPGRADED to STANDBY after pull/reinsert CC-backcard

CSCdp32760

Updates/Upgrades of circuit lines can cause a memory leak on the standby

CSCdp32823

IGX FAIL handler causes high CPU utilization

CSCdp34687

BPXs running 9.2.22 experiences commBreak every 5 seconds and cleared.

CSCdp34935

connCurrRouteDesc description inconsistent with code

CSCdp35155

LDM cderrs and card failed in 9.2.3M

CSCdp37572

Addcon command does not include connection display

CSCdp39883

Con with 1/101 VPI/VCI added at BXM fdr trunk caused UNRCH of its fdr

CSCdp41410

Modem Silence duration can be set to a maximum of only 5.1 seconds

CSCdp42776

Cannot configure BXM port by runjob command

CSCdp43913

Dsprsrc displays confusing information about Topo Discovery

CSCdp45833

SVC deletions are sometimes incomplete (swerr 332 with FFF1)

CSCdp47053

ALM/B Y-Red does not work for upgrade 8.5.09->9.1.15->9.2.23

CSCdp47428

IFC failed when shelf is re-added (with 2 partition)

CSCdp47479

Unable to configure feeder LMI timers

CSCdp48792

"The dsplog/trapd show the APS alarm cleared, but dspapsln is in LOS"

CSCdp48797

All connection parms go to 0 when change vc q depth

CSCdp48797

All connection parms go to 0 when change vc q depth

CSCdp49215

Addtrk on Y-red card causes swerr 9082

CSCdp49860

Dncon causes other connections to be downed

CSCdp49951

BPX hanging up with TUNL task using up to 60% CPU RT

CSCdp50593

Updated information PNNI ctrlr not sent after addctrlr command

CSCdp51318

No alarm of the APSLN in dsplog/dspapsln after Signal Degrade/Failure

CSCdp52802

UVM ports do not pass data due to stuck CCS conditioning

CSCdp53212

Dspload from IGX on a remote BPX with trunk no.> 8 is not allowed

CSCdp53891

Addloclp and addrmtlp command causes yellow alarm on UVI interface

CSCdp54106

"BCC switchcc causes Comm failure, telnet failure"

CSCdp54803

BCC switches over when standby is in update statistic with bad Spurious Int

CSCdp55388

Dspchuse shows wrong number for max PVC configured.

CSCdp55442

Addjob/editjob and cnfport corrupts memory or can cause a 1M3 abort

CSCdp58545

Distortion on UVM-to-CVM connections routed on UXM Trunks when VAD Threshold reached.

CSCdp58869

Unintelligent response from cnfcon command

CSCdp59960

UVM does not send yellow alarm to PBX when it receives a yellow alarm from PBX

CSCdp61539

"Networking channel deletion problem for Transparent, Blind and Inter-nodal"

CSCdp64345

Virtual trunk in comm fail is chosen by route or after hitless rebuild

CSCdp65187

Multiple switchyred within 10 seconds causes line to go in LOS for APS

CSCdp66930

No failed traps for user lockout but traps for BPX lockout

CSCdp69003

"Decrease Comm Brk clear, reroute and recondition time after rebuild"

CSCdp69582

Unable to switchyred on upgrade from BXM to BXM-E due to Qbin size mismatch

CSCdp70093

Failure configuring VSI ILMI gives error message Unknown error for LCN un avail.

CSCdp70295

"UNI port MIB should show range 1-255, not"

CSCdp73719

ILMI on card can be disabled through SNMP even if VSI ILMI enabled.

CSCdp76840

Resetcd on Active should warn when standby is still in PRGM mode.

CSCdp79429

Dspselftst shows test attempts incrementing yet Status always shows Not Run

CSCdp79560

TFTP Channel Stats are not reported correctly

CSCdp79719

Cnftrk on an IMA trunk shows negative transmit trunk rate!

CSCdp82720

Y-red: standby UXM does not take over when FW is burned on active card

CSCdp84848

Dsplogcd for a VSI trunk attempts to use an uninitialized pointer

CSCdp85171

Flood of HW failure messages from BXM caused node rebuild

CSCdp85238

Alarm are not getting updated when delapsln and switchyred/resetcd is done.

CSCdp86269

Trunks and LNs on aps cds go into LOS and never recover during gr253 -> ITUT.

CSCdp90123

Cnftrk for a vtrk on an OC12 interface gives a line coding prompt

CSCdp90130

Cnfrsrc shows more bandwidth than the physical maximum for a feeder.

CSCdp98715

Swlog 514 and 589 when doing dncon.

CSCdr00072

Using unitialized num_ports variable in av_bkcd()

Problems Fixed in Release 9.2.30

Following is the list of fixed problems in the 9.2.30 Switch Software release. Included with each is a brief description of the problem.

Bug ID  Description 

CSCdk36040

"Trap 20004-wrong value for varbind trapCardType, FRP back card"

CSCdk53336

Tstdelay not working on non-enhanced ASI-155

CSCdk87939

Dspchcnf shows inconsistent information after upgrade to 9106

CSCdm05502

Need cnfuvmchparm parameters 8 and 9 to configure UVM echo cancelers

CSCdm19532

A-bit status not propagating through network changing from NNI to UNI port

CSCdm19535

Channel program problems for BXM virtual trunks

CSCdm24140

Delcon on IGX causes IDLE RT to drop

CSCdm31990

CVM cbus message (0xA0) is not delivered when the secondary card is active.

CSCdm42254

When user ID is deleted subsequent users are reported one off.

CSCdm53182

Swerr 923 logged when dsptrkred command is used.

CSCdm65380

Allow conids lower than 4096 for VT wraparound

CSCdm72719

Unable to add BNI VT over ASI port in some cases

CSCdm74224

Unable to configure a port on OC-3 card when others are already configured.

CSCdm85764

"IGX node logging constant swerr 2051, TFTP_FILE_SIZE_ERR"

CSCdm85783

Five connections were deleted. software errors 614/612/534 were logged during a full rebuild

CSCdm86633

Swerr 332 (BD_XLAT_INDX) and 325 (BD_XLATDB_REF) on VNS SVCs

CSCdm88262

Able to add atfr DAX conns from frm.xx - uxm.xx with pcr < 50 and policing: on.

CSCdm91238

SWerr 2003 is seen during a switchcc

CSCdm91631

During ungraceful upgrade from 9.1 to 9.2, some BW PARMS can become allocated

CSCdm92021

Error_slot were used instead of next_slot when checking next_slot parity error.

CSCdm92790

Voice and NTS IGX traffic is serviced in VBR Q of BXM

CSCdm93670

Cannot configure 2 OC3 trunk has 7K PVCs

CSCdm93701

PVC shows inconsistent prefer route information

CSCdm94587

Swerr 532 and 923 when deltrk of trunk on downed card

CSCdp00060

Swerr 526(NEG_FILL_REQ)

CSCdp01511

"FRM - FRM, 2 seg. conn has cbr traffic type"

CSCdp02203

Could not add 3 seg. FR-FR connection from CM GUI (FRM - FRSM)

CSCdp03317

VT Path Failure condition remains after the downed VPC in the cloud

CSCdp04213

"Software error 3025 gets logged thrice, when do a walk on atmPortStatLmiStatAc."

CSCdp05149

1 mil 2 abort after full rebuild on N33

CSCdp06823

SW9082 after switchcc and tstconseg

CSCdp08636

BPX node showing a trunk connected to itself instead of popeye feeder

CSCdp11851

CMUP timeouts have to be increased to avoid thrashing

CSCdp12024

BPX sends wrong error messages to CWM

CSCdp12505

Memory should be moved from Pool Region to Hitless Region

CSCdp14002

Trunk fail/repair resets Concentric Comm Break Clearing etc.

CSCdp15671

Software error 105

CSCdp15712

Can not add con with certain VPI.VCI value

CSCdp16760

SWERR 3033 seen on BPX nodes

CSCdp16891

SWERR 532 seen on BPX nodes

CSCdp17303

Lines do nor show up in CWM 9.2.06M for certain BXM-E3/T3

CSCdp18093

Continuous BUS A|B Reports PRI LOSS (Clock) log messages when primclksrc = VT

CSCdp18160

False NNI failure indication at IGX FDR endpoint

CSCdp20894

Addlnloclp/dellnlp causes trunk Mgr Ret Yel and LOF (RED)

CSCdp20961

Swerr 5019 occured during loadrev and runrev 9.2.3F

CSCdp21688

Sec BXM card goes in mismatch during upgrade(9.1-9.2) when cards not in service.

CSCdp21803

Trapd log reports event trap on wrong node

CSCdp23116

"Continuous hitless rebuilds, if 1st abort is before hitless pointer"

CSCdp23196

Swerr 1101 (BAD_EVENT_TYPE) logged.

CSCdp23410

UXM physical trunks with VPI of 0 does not work

CSCdp24319

Dspcon for atfst connections does not display all parameters on second page

CSCdp24366

get_trunk() does not properly handle physical slot/logical slot mapping

CSCdp25420

A line which is upped can be configured as an IMA trunk

CSCdp25685

Software error 1012 logged upon a delshelf on a VSI trunk

CSCdp26827

Swerr 9082 logged for the nrtVBR conn 3.4.255.32852

CSCdp27775

Unable to add IGX feeder

CSCdp30654

LCN allocation issue with crosspoint test

CSCdp31596

IGX 9.2.22 NTM does not support FST in traffic class failing addtrk

CSCdp32058

Send CM update responses to unreachable nodes

CSCdp32815

Dspvsipartinfo display hangs; an issue for automating the testing

CSCdp34188

No continuity on a con routed over a BXM FDR to a IGX feeder

CSCdp35713

Channel for NW use counted twice

CSCdp39714

Move disabling of VPC conns upgrade to 9.2.30 from 9.2.23

Problems Fixed in Release 9.2.23

Following is the list of fixed problems in the 9.2.23 Switch Software release. Included with each is a brief description of the problem.

Bug ID  Description 

CSCdm64323

Swerr 3005 BAD_DEFAULTS seen on two BPX nodes.

CSCdp25375

Abort does not cause hitless rebuild or switchcc (full rebuild instead)

Problems Fixed in Release 9.2.22

Following is the list of fixed problems in the 9.2.22 Switch Software release. Included with each is a brief description of the problem.

Bug ID  Description 

CSCdp04046

Increase cm update time-out from 30 seconds to 90 seconds

CSCdp05661

Node is unreachable from one side but the route is fine

CSCdp10383

Tftp file stats for PHYSLINE object reports all ports as zero

Problems Fixed in Release 9.2.21

Following is the list of fixed problems in the 9.2.21 Switch Software release. Included with each is a brief description of the problem.

Bug ID  Description 

CSCdj57458

Reduce privilege level for dspqs command

CSCdj79112

BXM does not allow SCR/CIR less than 50cps/19.2kbps

CSCdk26279

Block a user from disabling CAC override if ATM port is over subscribed

CSCdk34722

Enable EPD configuration on all BXM queues. Allow clp-lo > clp-hi. (UXM)

CSCdm06156

"Sim-fdrs on BNIs are unreachable after rebuild, bad loopback rebuild"

CSCdm19696

BME port configure is blocked need to set CAC override and shift on/off

CSCdm36041

"When active BCC backcard is removed, no info to dsplog"

CSCdm38356

100% Cell Loss on ALM/A VPCs (GW_TYPE_CELL_VPC) routed over ALM/B trunks

CSCdm40129

Crosspoint test failing on some BXM trunk test cases

CSCdm46335

Swerr 9091 on BPX node due to a tstdelay failure

CSCdm46537

Addcon does not check egress load with cac override disable and %util enable

CSCdm47933

Output of dspnds -d is larger than screen and columns wrap around

CSCdm51607

Print function is not working correctly (format issue)- ok 8.4 & broke

CSCdm52681

Switchyred causes data transfer stops for 1 to 4 minutes

CSCdm58441

Dcdrtbl on UXM card logs a BAD_CD_TYPE (55) swerr

CSCdm58804

Swerr 8096 logged on IST n/w for nightly jobs

CSCdm60541

Software error 919 (BAD_SVR_CNTR_PTR) was logged on BPX node in IST n/w

CSCdm61885

During a burnfwrev in a UXM card, it does not shows as program

CSCdm62078

Swerr 986 occured during cnftrk virtual trunk

CSCdm63072

Software errors 31 and 52 with addlocrmtlp where remote end is BPX feeder

CSCdm63583

DSPCONS -FABIT sometimes shows A-bit status incorrectly as UNUSED

CSCdm64034

Hitless rebuild count is not getting incremented

CSCdm64066

Tstdelay on the UXM conn fails reporting with state table hung

CSCdm64811

APS: switchyred causes LOS for 10 seconds

CSCdm65813

APS: switch back to working line incorrectly.

CSCdm68729

AIS getting generated on remotely looped back connections

CSCdm70167

Software error 104 after loading 9.2.2L

CSCdm71616

Cannot delete link from UXM-IMA virtual trunk

CSCdm73852

Feature mismatch may not be working for 1 port group BXM cards

CSCdm74630

Swerr 1415 logged in BPX

CSCdm76753

Shorten the error string displayed for supported load types for trunk

CSCdm76881

"Addyred not possible when upgrading from 8.4.21 to 9.1 or 9.2, in on"

CSCdm77070

Alarm-a line VPC mode can be changed when there are VPC cons on it!

CSCdm77509

AXIS feeder shows incorrectly as a MGX feeder

CSCdm80991

Unable to add conns using CM GUI with BPX 9.2.20 & MBE firmware

CSCdm83096

Failed to addyred on LDM: RCMP entries mismatch

CSCdm89320

BPX lmi messages to AXIS shelf do not contain correct I.E.

CSCdp05584

During 9.1->9.2 upgrade, user connection channels are allocated for cc traffic

CSCdp05865

BXM-E3/T3 cards show up as wrong card on SV+

Problems Fixed in Release 9.2.20

Following is the list of fixed problems in the 9.2.20 Switch Software release. Included with each is a brief description of the problem.

Bug ID  Description 

CSCdk33999

"Connections automatically removed, SWERR 532 BAD_LCD_INDEX,SWERR 590 SEND_FAIL"

CSCdk34492

SNMP Agent - Wrong value returned for atmOtherEndptDesc

CSCdk85811

LAN fuse failed on NPM

CSCdk89665

Cannot configure line framing and signalling to NONE on UFM-C

CSCdk93626

Minimum MCR range is different in CLI & strata.mib

CSCdm00711

Hardware watchdog on NPM-32 when SNMP community strings configured

CSCdm08324

BXMs enables a BNIs CRXL statistic

CSCdm27574

Remove and reinsert Tx Fdr Trk cable causes connection failure.

CSCdm27726

CD errors: N. Fatal from 0x17: 0x25010022 0x0 0x22af 0x1 logged on BXM

CSCdm32599

NPM not recognizing traps with BXM ILMI at the cloud

CSCdm41637

Cnfpref buffer too short to load many 10 pref routes

CSCdm43422

Switch software does not dsptrkutl for NTM trunk

CSCdm43783

Swerr 55 occured after loadrev 9.2.1C in graceful upgrades

CSCdm44536

Swerr 532 & 55 cause by dcdrtbl on BXM & BNI trunks

CSCdm50232

Swerr 2000 logged on the node when trunk parameter is displayed through CiscoView

CSCdm50251

BPX: Port Real-Time Counters show incorrect values

CSCdm50372

Axis shelves report LMI failure when do hitless rebuild.

CSCdm51357

Swerr 121 on l3a(IGX)

CSCdm52990

Node experiences repeated abort 3M and 1M3 due to flooding on LMI channel

CSCdm53035

"Non-added trunks, the queue depth value should be changed with the line rate."

CSCdm53119

Swerr 129 is logged when dspswlog s command is executed on BPX node p6b

CSCdm53126

User ID updates do not stop if all nodes have invalid password for a user

CSCdm53376

Statistical trunk errors are not reported under dsptrkerrs

CSCdm54117

Swerr 9082s were logged at IST node igxr5

CSCdm56012

New versions of enhanced BXM card types need to be sent to SV.

CSCdm57535

Atmportstatmap_Table not getting initialized for ATM_PORT_STAT_BCM_RX_OFFSET

CSCdm58398

The trunk speed shown for dsptrkstats is incorrect

CSCdm59091

LDM & CVM conns cannot be modified by SV+ after upgrade

CSCdm59267

Additional ATM con subtypes need to be sent to SV+

CSCdm59268

Transaction handler sometimes is very busy on IGX

CSCdm61126

BPX reports incorrect status when burning firmware failed

CSCdm62548

Swerr 2085 occurs during a regression test.

CSCdm63487

Cnftrk does not prompt for Header Type: field

CSCdm63889

BCC reseated and remained in an update stage after BXMMEA upgrade

CSCdm64045

Software errors 886 and 2071 on image upgrade

CSCdm65060

Could not build a UNI IMA Group between IMATM and IGX UXM

CSCdm65089

Continuous PRI Clock loss messages in LOG

CSCdm65104

HDM failed the testcon command if its back card is configured as DTE

CSCdm66452

Tstber in manual mode stops receiving after nearly 1 1/2 hours.

CSCdm67094

Cnfasm is very detached from ASM functionality

CSCdm67130

ABR class of service is delayed from trunks

CSCdm67358

502/589/504/3m/1m3 and standby continuously WDTs

CSCdm68678

IMA virtual trunk configuration display will log swer 633 (LN_CNFG_DSP_OVFLW)

CSCdm69180

Cnftrk on UXM fdr trunk should be blocked if new LCNs are < used lcns

CSCdm69421

Traffic type displayed on cnftrk is not cleaned up correctly.

CSCdm69834

Default service template while upgrading from 9.1x to 9.2x

CSCdm72193

Unable to add UXM trunk

Problems Fixed in Release 9.2.10

Following is the list of fixed problems in the 9.2.10 Switch Software release. Included with each is a brief description of the problem.

Bug ID  Description 

CSCdk21358

Front cards do not refresh if back cards are removed.

CSCdk26240

AIS transitions are not counted

CSCdk29716

Three-way PVC on frame relay connections after switchover

CSCdk33721

Swerr 614 is logged while doing a graceful upgrade

CSCdk51121

Dsplnalmcnf does not include trunks alarm configuration

CSCdk51259

slotBackNumPort is valid only for UXM and BXM cards

CSCdk55034

E3 BIP8 alarm error threshold is not triggered at 10E-3

CSCdk65743

Watchdog in VT_1 task (split off from CSCdk63204)

CSCdk69040

Adding cons to full port gives wrong return message

CSCdk77005

IGX16 logged 1000003 w/ SNMP process

CSCdk87933

"During SAR flood testing, some connections were autodelete"

CSCdm02272

BPX went into DEGRADED mode when cmd DSPLOGCD was initiated

CSCdm04372

Wrong atmPortIfType is returned for BXM-T3 card

CSCdm04812

Dspstatsinfo is counting feeder connections

CSCdm14446

No continuity for 3-byte frames routed over a UXM trunk

CSCdm18555

Need to redesign RCMP mismatch algorithm to allow use upgrade/downgrade card.

CSCdm19544

BPX 9.2 dspchstats does not show RX AIS

CSCdm24031

Burning old BXM FW to enhanced card will kill the card.

CSCdm29600

"After non graceful upgrade, swerrs 374, 752, Abort 1000003, can not add conns."

CSCdm36631

T3 trunk modification generates APS(OC3) traps

CSCdm37694

RtOp ran before ch clean up after 9.1.09 - 9.2.ja gracefully upgraded on UX

CSCdm37802

Swerr 706 in IGX feeder

CSCdm39210

Cnfcdaps causes a discrepancy between card attribute table and LCCB

CSCdm39227

CAC does not function correctly on a UXM port

CSCdm39836

Mib lacks definition for 8 port BNC connector card uaie1

CSCdm39871

MIB variable slotCardBackRev returns EW while it shows in CLI for ARM.

CSCdm40006

Add UXM/BXM VT to dspblkdfuncs and block in mixed NW

CSCdm40707

Swerr 4229 occurred after switchcc on BPX node

CSCdm41274

"Delyred logged swerr 514, 589, 143"

CSCdm41406

CPU usage above threshold message when do switchcc on 12000 conn node.

CSCdm41415

Dsptrkcnf/cnftrk does not show maximum channels for BNI trunks

CSCdm41881

"Swerr 514,589,502 logged on STBY BCC in l5b"

CSCdm42754

"Abort 2M when redundant CC, TFTP stats enabled, and a hitless is done"

CSCdm43471

SV+ can not see switch software 9.1.09 IGX-IGX FR Conns

CSCdm44056

APS Annex B switch software modifications

CSCdm44387

Swerr 1433 reported after switchcc

CSCdm44587

Swerr 29 BAD_PORT_NUM is reported on BPX node

CSCdm44973

Cnflnalm display shows alarm information on the wrong line of screen (after modifying)

CSCdm45274

Unable to configure Max LCNS to 32K on BXM-622-2DX card.

CSCdm45592

2068s and 504s flood log if statistics enabled before and after a hitless rebuild.

CSCdm45812

Block APS switching from standby to active line.

CSCdm45889

Swerrs 509 & 101 in IST n/w

CSCdm46095

Swerror 526 on adding or deleting APS lines

CSCdm46601

Software error 116 (BAD_OBJ_RESP) on statistic queries

CSCdm46790

"Memory leak in TRNS, SWERR 501, ABORT 3M, adaptive voice BW update msg leak."

CSCdm47814

Software error 9000 happens when UXM is activated in middle of its self-test

CSCdm48694

Robust card object message does not give Y redundancy information

CSCdm49385

Continuous hitless rebuild in case of abort

CSCdm49988

BXM card mismatch after upgrading from 9.109 to 9.2.01

CSCdm51212

3M Abort on BPX91 in IST n/w

CSCdm54599

UXM-FRM conns do not have continuity after a graceful upgrade (9.1.11->9.2.1K)

CSCdm54814

"549, 886 and 2071 occur on a rebuild, 928 on upping line"

Problems Fixed in Release 9.2.01

Following is the list of fixed problems in the 9.2.01 Switch Software release. Included with each is a brief description of the problem.

Bug ID  Description 

CSCdj15839

False power supply over voltage or under voltage alarms reported

CSCdj31366

Clrcnf command to have explicit double warning message.

CSCdk21503

Swerr 921 on node n1a in 9.1 SLT n/w

CSCdk28204

Swerr 526 happened after switchcc on sw79

CSCdk29850

protocol_type column in frp table returns wrong number for IPX switch problem.

CSCdk32046

Cnfclnsigparm option 9 should not apply to FRM/FRP/UFM-C lines

CSCdk40766

Multiple upgrade/downgrade messages sent by switch software cause modem upgrade failure.

CSCdk47079

SW ERR 1000003 while running dth

CSCdk52672

Added PVCs after switchcc is auto-deleted.

CSCdk56688

Hipri error message problem

CSCdk69440

IGX running swsw 9.1.04 has dspprf IDLE at 30% when adding UVM cards

CSCdk69498

Incorrect A-bit status in FR NNI link

CSCdk72199

IMA trunk load db not updating after trunk failure

CSCdk74438

Addcon does not work with job (job does not take 8/8 options)

CSCdk82927

Slow TCP / Telnet response & disconnects on LAN pt after upgrade to NPM64

CSCdk83511

Correlation tag not checked at BPX Port

CSCdk87005

Avoid satellite *s needs extra parameters with an addcon

CSCdk91395

Vague error message when attempting to reconfigure remote PCR > T1/E1 port speed

CSCdk92892

The FTMs bandwidth is not configured when a FAX session is complete

CSCdm05373

Incorrect UVM channel configuration used

CSCdm07825

2065 caused when enabling invalid statistics configuration (fix is known)

CSCdm10020

Shelf alarm is unreachable on BPX (9.1) with IGX feeder graceful upgrade 9.1.08-9.

CSCdm13012

Can upped 31 vtrk and 1 port on a BXM. Card reported missing after down

CSCdm15043

Dangling LCNs might happen under some conditions.

CSCdm16904

"SWSW repeatedly reprograms same connections, nonstop in a loop, on UXM"

CSCdm17109

Software error 526 (NEG_FILL_REQ) occurred on IGX node

CSCdm20480

Card shows standby while cons are in the card

CSCdm20716

"Switchcc causes swerr 331 if on1 16, some reroutes if any VPC cons"

CSCdm22316

VSI feeder endpoint connections traffic are not mapping the vpi/vci correctly.

CSCdm23206

Cnfcon faces problem in accepting TCRR value through command line.

CSCdm23489

Swerr 514 is logged on bpx01 in upgrades testing

CSCdm23669

"921s filled software error log, appears to be related to a trunk deletion."

CSCdm24282

LM3 caused by cnfch command

CSCdm25268

LMI is still in loop on bpx/axis after upgrade

CSCdm25595

Dspcons shows PVCs but dspcon does not on BPX

CSCdm26897

Free the memory for IP relay message.

CSCdm27681

Y-red UXM/IMA back cards came up as mismatch after a graceful upgrade 9.1.09-9.2.0N

CSCdm28561

"4225,614,534,612, 4208, 3058 logged on switchover, stolen log end is root cause."

CSCdm28721

Swerr 532 in l5b

CSCdm29043

Potential for card errors with add_cd_red_cons() function.

CSCdm29706

Ports cannot configure HCF shift on/off w/out deleting connections

CSCdm30018

Trunk Cell routing restriction is not prompted any more for ATM conn.

CSCdm30262

Incorrect logic for VTs in g_ima_grp_member()

CSCdm30359

Failed to add daxcon path connection due to incorrect VPI checking.

CSCdm30608

Software error 55 after addalmslot 16

CSCdm31674

Yellow alarm line conditioning for T1 lines

CSCdm32384

Node rebuild on BPX caused comm fail.

CSCdm33967

After upgrade 9.1.09 to 9.2.00 trunks went comm. failure and then OK

CSCdm34282

Dbs_Pre_9110 not initialized properly in Root()

Additional Deliverables

SNMP MIB

The SNMP IGX/BPX switch SNMP MIB is being provided with the delivery of Release 9.2.37 Switch Software. The MIB is in standard ASN.1 format and is located in the ASCII text files agent.m, ilmi.m, ilmi_ctl.m, ilmiaddr.m, switch.m, swtraps.m, and errors.m which are included in the same directory as the Switch Software images. These files may be compiled with most standards-based MIB compilers.

Switch MIB changes of Release 9.2

The following Switch MIB changes were introduced since Release 9.2.00. The changes include Obsolete objects, Modified objects, and New objects:

switchIfTable
New objects:
switchIfCtrlVPI
switchIfCtrlVCIStart

Modified objects:
switchIfEntry
switchIfScTmpltId

atmPortTable:
New objects:
atmPortHcfShift

Modified objects:
atmPortEntry
atmPortMetro

atmPortQueueTable:
Modified objects:
atmPortQueueType
atmPortQueueDepth
connTable:
Modified objects:
connCurrRouteDesc
connPrefRouteDesc

atmEndptTable:
Modified objects:
atmEndptDesc
atmOtherEndptDesc
atmEndptSubType
atmEndptMCR

atmBwClassTable:
Modified objects:
atmBwClassConType

The following objects are associated with the switchShelf configuration branch.

New objects:
shelfCnfgFBTC
shelfCnfgSerialLeadTypeIndex
shelfCnfgSerialLeadMonitorTimer
shelfCnfgSystemTime

shelfSlotInfoTable:
Modified objects:
slotBackType
slotFrontNumPort
slotBackSonetMode
slotCardMinBusUBU
sonetIfTable:
Modified objects:
sonetIfType

sonetStatsTable:
New objects:
sonetStatsYelTcs
sonetStatsAisTcs
sonetStatsLocs
sonetStatsLops
sonetStatsPthAis
sonetStatsPthYels
sonetStatsSecBip8s
sonetStatsLnBip24s
sonetStatsLnFebes
sonetStatsPthBip8s
sonetStatsPthFebes
sonetStatsSecBip8Es
sonetStatsLnBip24Es
sonetStatsLnFebeEs
sonetStatsPthBip8Es
sonetStatsPthFebeEs
sonetStatsSecBip8Ses
sonetStatsSecSefs
sonetStatsLnBip24Ses
sonetStatsLnFebeSes
sonetStatsPthBip8Ses
sonetStatsPthFebeSes
sonetStatsLnUas
sonetStatsLnFarendUas
sonetStatsPthUas
sonetStatsPthFarendUas
sonetStatsHcsCrtblErrEs

Modified objects:
sonetStatsEntry

atmTrunks table:
Modified objects:
atmTrkType
atmTrkTrafCls

rsrcPartiTable:
New objects:
rsrcPartiVsiIlmiEnable

Modified objects:
rsrcPartiEntry
rsrcPartiVsiVpiEnd

serialPortTable:
New objects:
serialPortLeadState

Modified objects:
SerialPortEntry
serialPortLeadState

Default Values

BPX 8600 Nodes

The default values for BXM and Enhanced-BXM cards are the same.

hugo       TN    StrataCom       BPX 8620  9.2.37    Feb. 7 2001  16:19 GMT 
                                                                                
                           System-Wide Parameters                               
                                                                                
1  Max Time Stamped Packet Age (msec) ................................   32     
2  Allow CPU Starvation of Fail Handler ..............................   No     
3  Max Network Delay for 'v' connections (msec).......................   14     
4  Max Network Delay for 'c' connections (msec).......................   27     
5  Max Network Delay for 't' & 'p' connections (msec).................   14     
6  Max Network Delay for 'a' connections (msec).......................   27     
7  Max Network Delay for High Speed Data connections (msec)...........   32     
8  Max Network Delay for CDP-CDP 'v' connections (msec)...............   64     
9  Max Network Delay for CDP-CDP 'c' connections (msec)...............   64     
10 Max Network Delay for CDP-CDP 't' & 'p' connections (msec).........   64     
11 Max Network Delay for CDP-CDP 'a' connections (msec)...............   64                                                                                                            
12 Max Network Delay for CDP-CDP High Speed Data connections (msec)...   64     
13 Enable Discard Eligibility.........................................   No     
14 Use Frame Relay Standard Parameters Bc and Be......................   No     
15 Max Local Delay for Interdom CDP-CDP 'v' conns (msec)..............   27     
16 Max Local Delay for Interdom CDP-CDP 'c' conns (msec)..............   27     
17 Max Local Delay for Interdom CDP-CDP 't' & 'p' conns (msec)........   27     
18 Max Local Delay for Interdom CDP-CDP 'a' conns (msec)..............   27     
19 Max Local Delay for Interdom CDP-CDP High Speed Data conns (msec)..   27     
20 Max Local Delay for Interdom High Speed Data conns (msec)..........   28     
21 FastPAD Jitter Buffer Size  (msec).................................   15     
22 Number of Consecutive Invalid Login Attempts to Cause Major Alarm .    0                                  
23 Enable Connection Deroute Delay feature............................   No     
24 Interval Statistics polling rate for ATM VCs.......................    5     
25 Interval Statistics polling rate for ports on IPX/IGX 8400 nodes...    5     
                                                                                                                                                                                                                      
                                                                                
This Command: cnfsysparm                                                        
                                                                                
hugo       TN    StrataCom       BPX 8620  9.2.37    Feb. 7 2001  16:20 GMT 
                                                                                
1  Update Initial Delay   [ 5000] (D)   16 Stats Memory (x 100KB) [  132] (D)   
2  Update Per-Node Delay  [30000] (D)   17 Standby Update Timer   [   10] (D)   
3  Comm-Break Test Delay  [30000] (D)   18 Stby Updts Per Pass    [   50] (D)   
4  Comm-Break Test Offset [   10] (D)   19 Gateway ID Timer       [   30] (D)   
5  Network Timeout Period [ 1700] (D)   20 GLCON Alloc Timer      [   30] (D)   
6  Network Inter-p Period [ 4000] (D)   21 Comm Fail Delay        [   60] (D)   
7  NW Sliding Window Size [    1] (D)   22 Nw Hdlr Timer (msec)   [   50] (D)   
8  Num Normal Timeouts    [    7] (D)   23 SAR CC Transmit Rate   [  560] (D)   
9  Num Inter-p Timeouts   [    3] (D)   24 SAR High Transmit Rate [  280] (D)   
10 Num Satellite Timeouts [    6] (D)   25 SAR Low Transmit Rate  [   56] (D)   
11 Num Blind Timeouts     [    4] (D)   26 SAR VRAM Cngestn Limit [ 7680] (D)   
12 Num CB Msg Timeouts    [    5] (D)   27 SAR VRAM Cell Discard  [  256] (D)   
13 Comm Fail Interval     [10000] (D)   28 ASM Card Cnfged        [    Y] (Y/N) 
14 Comm Fail Multiplier   [    3] (D)   29 TFTP Grant Delay (sec) [    1] (D)   
15 CC Redundancy Cnfged   [    Y] (Y/N) 30 TFTP ACK Timeout (sec) [   10] (D)   
                                                                                                                                                              
31 TFTP Write Retries     [    3] (D)   46 Max Htls Rebuild Count [  100] (D)   
32 SNMP Event logging     [    Y] (Y/N) 47 Htls Counter Reset Time[ 1000] (D)   
33 Job Lock Timeout       [   60] (D)   48 Send Abit early        [    N] (Y/N) 
34 Max Via LCONs          [50000] (D)   49 Abit Tmr Multiplier  M [    0] (D)   
35 Max Blind Segment Size [ 3570] (D)   50 Abit Tmr Granularity N [    3] (D)   
36 Max XmtMemBlks per NIB [ 3000] (D)   51 FBTC with PPDPolicing  [    N] (Y/N) 
37 Max Mem on Stby Q (%)  [   33] (D)                                           
38 Stat Config Proc Cnt   [ 1000] (D)                                           
39 Stat Config Proc Delay [ 2000] (D)                                           
40 Enable Degraded Mode   [    Y] (Y/N)                                         
41 Trk Cell Rtng Restrict [    Y] (Y/N)                                         
42 Enable Feeder Alert    [    N] (Y/N)                                         
43 Reroute on Comm Fail   [    N] (Y/N)                                         
44 Auto Switch on Degrade [    Y] (Y/N)                                         
45 Max Degraded Aborts    [  100] (D)                                           
                                                                                
This Command: cnfnodeparm                                                       
                                                                                
hugo       TN    StrataCom       BPX 8620  9.2.37    Feb. 7 2001  16:20 GMT 
                                                                                
Index Status    Function                                                        
                                                                                
1     Enabled   Automatic TRK Loopback Test on Local/Remote Alarms              
2     Enabled   User Command Logging                                            
3     Enabled   Automatic Card Reset on Hardware Error                          
4     Enabled   Card Error Record Wraparound                                    
5     Disabled  Card Test After Failure                                         
6     Disabled  Download From Remote Cisco StrataView Plus                      
7     Disabled  Logging of conn events in local event log                       
8     Disabled  Logging of conn events in Cisco StrataView Plus  event log      
9     Disabled  Force Download From a Specific IP address                       
                                                                                                                                          
                                                                                
This Command: cnffunc 

hugo       TN    StrataCom       BPX 8620  9.2.37    Feb. 7 2001  16:20 GMT 
                                                                                
Index Status    Function                                                        
                                                                                
1     Disabled  Configuration Save/Restore                                      
2     Enabled   ForeSight                                                       
3     Disabled  Multiple VTs (1 session enabled)                                
4     Disabled  Virtual Trunks                                                  
5     Enabled   ABR standard with VSVD                                          
                                                                  
                                                                                
This Command: cnfswfunc                                                         
                                                                                
hugo       TN    StrataCom       BPX 8620  9.2.37    Feb. 7 2001  16:20 GMT 
                                                                                
Card    Test   - - - - - - Self Test - - - - - - -   - - Background Test - - -  
Type    Freq   Enable        Inc   Thresh  Timeout   Enable        Inc   Thresh 
----    -----  --------  -------  -------  -------   --------  -------  ------- 
BCC      1600  Enabled       100      300      800   N/A           100      300 
ASM       300  Disabled      100      300       60   N/A           100      300 
BNI-T3    300  Enabled       100      300      150   N/A           100      300 
BNI-E3    300  Enabled       100      300      150   N/A           100      300 
ASI-E3    900  Enabled       100      300      800   Enabled       100      300 
ASI-T3    900  Enabled       100      300      800   Enabled       100      300 
ASI-155   900  Enabled       100      300      800   Enabled       100      300 
BNI-155   300  Enabled       100      300      150   N/A           100      300 
BXM      4000  Enabled       100      300     3000   Enabled       100      300 
                                                                                
                                                                                

This Command: cnftstparm                                                        
                                                                                
hugo       TN    StrataCom       BPX 8620  9.2.37    Feb. 7 2001  16:20 GMT 
                                                                                
1  Normalization Interval    [    2] (D)                                        
2  Max Number To Normalize   [    5] (D)                                        
3  Normalization Logging     [   No]                                            
4  Settling Interval         [    4] (D)                                        
5  Minimum Open Space        [ 1000] (D)                                        
6  Normalization Priority    [ Load]                                            
7  Load Sample Period        [    4] (D)                                        
8  Maximum Routing Bundle    [   90] (D)                                        
9  Reroute Timer             [    0] (secs)                                     
10 Reset Timer on Line Fail  [  Yes]                                            
11 Max Down/Up Per Pass      [   50] (D)                                        
12 Down/Up Timer             [30000] (msecs)                                    
13 Max Route Errs per cycle  [   50] (D)                                        
14 Time between Rrt cycles   [    5] (mins)                                     
15 Max. Rrt Err cycles       [   10] (D)                                                                                                                      
16 Routing pause timer       [    0] (msecs)                                    
17 Max msgs sent per update  [   10] (D)                                        
18 Send SVC urgent msg       [   No]                                            
19 Max SVC Retry             [    0] (D)                                        
20 Wait for TBL Updates      [   70] (100 msecs)                                
21 Max Derouting Bndl (0=all)[  500] (D)                                        
22 Enable Cost-Based Routing [   No]                                            
23 Enable Route Cache Usage  [   No]                                            
24 Use Delay for Routing     [   No]                                            
25 # of reroute groups used  [   50] (D)                                        
26 Starting size of RR grps  [    0] (CLU)                                      
27 Increment between RR grps [  100] (CLU)                                      
                                                                                                                                                    
                                                                                
This Command: cnfcmparm 
hugo       TN    StrataCom       BPX 8620  9.2.37    Feb. 7 2001  16:21 GMT 
                                                                                
1  Rmt Blk Freq (msec)     [    100]    16 FW Dnld Msgs/Block(dec) [      4]    
2  Rmt Blk Size (hex)      [    400]    17 Flash Write TO(msec)    [  16000]    
3  Lcl Blk Freq (msec)     [    100]    18 Flash Erase TO(msec)    [    100]    
4  Lcl Blk Size (hex)      [    400]    19 Erase Verify TO(msec)   [  16000]    
5  Image Req Freq (msec)   [  10000]    20 Standby Flash TO(sec)   [    300]    
6  Dnld Req Freq (msec)    [  10000]    21 Lcl Flash Init TO(msec) [   1000]    
7  Session Timeout (msec)  [  30000]    22 Flsh Write Blk Sz (hex) [  10000]    
8  Request Hop Limit (dec) [      1]    23 Flsh Verfy Blk Sz (hex) [    400]    
9  Crc Throttle Freq (dec) [   5000]    24 Chips Per Write/Erase   [      1]    
10 Crc Block Size (hex)    [    400]                                            
11 Rev Change Wait(dec)    [      0]                                            
12 CCs Switch Wait(dec)    [   1000]                                            
13 Lcl Response TO(msec)   [   5000]                                            
14 Rmt Response TO(msec)   [  20000]                                            
15 FW Dnld Block TO(msec)  [     50]                                            
                                                                                
This Command: cnfdlparm                                                         
                                                                                
hugo       TN    StrataCom       BPX 8620  9.2.37    Feb. 7 2001  16:21 GMT 
                                                                                
1. Logout Time ........... 20 minutes                                           
2. VT Logout Time ........ 4 minutes                                            
3. Prompt Time ........... 60 seconds                                           
4. Command Time .......... 3 minutes                                            
5. UID Privilege Level ... 6                                                    
6. Input Character Echo .. Enabled                                              
7. Screen Update Time .... 10 seconds                                           
                                                                                                                                       
                                                                                
This Command: cnfuiparm                                                         
                                                                                
hugo       TN    StrataCom       BPX 8620  9.2.37    Feb. 7 2001  16:21 GMT 
                                                                                
Function            Number   Status      Function            Number   Status    
Background Upcard     1      Enabled     Conn Stat Sampling    15     Enabled   
Background Updates    2      Disabled    Neighbor Update Errs  16     Disabled  
Standby Terminal      3      Enabled                                            
Memory Protection     4      Enabled                                            
Comm Break            5      Enabled                                            
Comm Fail Test        6      Enabled                                            
CRC Test              7      Enabled                                            
Bus Fail Detection    8      Enabled                                            
Line Diag             9      Enabled                                            
Clock Restoral        10     Enabled                                            
Cm_Rerouting          11     Enabled                                            
Clock Routing         12     Enabled                                            
Dynamic BW Allocation 13     Enabled                                            
Modem Polling         14     Enabled                                            
                                                                                
This Command: on1                                                               
                                                                                
hugo       TN    StrataCom       BPX 8620  9.2.37    Feb. 7 2001  16:21 GMT 
                                                                                
Function            Number   Status      Function            Number   Status    
Line Stat Sampling    1      Enabled     Robust Alarm Updates  15     Enabled   
Statistical Alarm     2      Enabled     Realtime Counters     16     Enabled   
Job Ready Checker     3      Enabled     LAN Interface         17     Enabled   
Configuration Backup  4      Enabled     Update Standby Stats  18     Enabled   
Standby Update        5      Enabled     Telnet Access         19     Enabled   
Downloader            6      Enabled     Junction ID           20     Enabled   
Cm Updates            7      Enabled     Mult SV+/Routing Node 21     Disabled  
Topo/Stat Updates     8      Enabled     Simulated Fdr Trks    22     Disabled  
Card Statistical Alms 9      Enabled     Deroute Delay         23     Enabled   
Card Stat Sampling    10     Enabled     Auto Renum Fail Recov 24     Enabled   
Address Validation    11     Enabled     Card Simulation Tool  25     Disabled  
ASM Stats Polling     12     Enabled                                            
Port Stat Sampling    13     Enabled                                            
Robust Updates        14     Enabled                                            
                                                                                
This Command: on2                                                               
                                                                                
                                                                                
hugo       TN    StrataCom       BPX 8620  9.2.37    Feb. 7 2001  16:21 GMT 
                                                                                
Function            Number   Status                                             
Region memory init    1      Disabled                                           
Trace Msg Sent        2      Disabled                                           
Multi-DB Stby Updates 3      Enabled                                            
Trace Conv Msg        4      Disabled                                           
                                                                                                                                                                                                              
                                                                                
This Command: on3 

BNI-T3

hugo       TN    StrataCom       BPX 8620  9.2.37    Feb. 7 2001  16:22 GMT 
                                                                                
TRK  3.1 Config     T3     [96000 cps]     BNI-T3 slot:  3                      
Transmit Rate:         96000               VPC Conns disabled:    --            
Protocol By The Card:  --                  Line framing:          PLCP          
VC Shaping:            --                       coding:           --            
Hdr Type NNI:          --                       recv impedance:   --            
Statistical Reserve:   1000    cps              cable type:                     
Idle code:             7F hex                         length:     0-225 ft.     
Connection Channels:   1771                Pass sync:             No            
Traffic:V,TS,NTS,FR,FST,CBR,N&RT-VBR,ABR   Loop clock:            No            
SVC Vpi Min:           --                  HCS Masking:           Yes           
SVC Channels:          0                   Payload Scramble:      No            
SVC Bandwidth:         0      cps          Frame Scramble:        --            
Restrict CC traffic:   No                  Virtual Trunk Type:    --            
Link type:             Terrestrial         Virtual Trunk VPI:     --            
Routing Cost:          10                  Deroute delay time:    0 seconds     
                                                                                
Last Command: dsptrkcnf 3.1                                                     
                                                                                

hugo       TN    StrataCom       BPX 8620  9.2.37    Feb. 7 2001  16:22 GMT 
                                                                                
TRK 3.1 Parameters                                                              
 1 Q Depth - rt-VBR    [  242] (Dec)    15 Q Depth   - CBR     [  600] (Dec)    
 2 Q Depth - Non-TS    [  360] (Dec)    16 Q Depth   - nrt-VBR [ 1000] (Dec)    
 3 Q Depth - TS        [ 1000] (Dec)    17 Q Depth   - ABR     [ 8878] (Dec)    
 4 Q Depth - BData A   [ 1000] (Dec)    18 Low  CLP  - CBR     [ 100] (%)       
 5 Q Depth - BData B   [ 8000] (Dec)    19 High CLP  - CBR     [ 100] (%)       
 6 Q Depth - High Pri  [ 1000] (Dec)    20 Low  CLP  - nrt-VBR [ 100] (%)       
 7 Max Age - rt-VBR    [   20] (Dec)    21 High CLP  - nrt-VBR [ 100] (%)       
 8 Red Alm - I/O (Dec) [  2500 /  15000]22 Low CLP/EPD-ABR     [  60] (%)       
 9 Yel Alm - I/O (Dec) [  2500 /  15000]23 High CLP  - ABR     [  80] (%)       
10 Low  CLP - BData A  [ 100] (%)       24 EFCN      - ABR     [  30] (%)       
11 High CLP - BData A  [ 100] (%)       25 SVC Queue Pool Size [    0] (Dec)    
12 Low  CLP - BData B  [  25] (%)                                               
13 High CLP - BData B  [  75] (%)                                               
14 EFCN     - BData B  [  30] (Dec)                                             
                                                                                
This Command: cnftrkparm 3.1 

BNI-E3

hugo       TN    StrataCom       BPX 8620  9.2.37    Feb. 7 2001  16:22 GMT 
                                                                                
TRK  4.1 Config     E3     [80000 cps]     BNI-E3 slot:  4                      
Transmit Rate:         80000               VPC Conns disabled:    --            
Protocol By The Card:  --                  Line framing:          --            
VC Shaping:            --                       coding:           --            
Hdr Type NNI:          --                       recv impedance:   --            
Statistical Reserve:   1000    cps              cable type:                     
Idle code:             7F hex                         length:     0-225 ft.     
Connection Channels:   1771                Pass sync:             No            
Traffic:V,TS,NTS,FR,FST,CBR,N&RT-VBR,ABR   Loop clock:            No            
SVC Vpi Min:           --                  HCS Masking:           Yes           
SVC Channels:          0                   Payload Scramble:      Yes           
SVC Bandwidth:         0      cps          Frame Scramble:        --            
Restrict CC traffic:   No                  Virtual Trunk Type:    --            
Link type:             Terrestrial         Virtual Trunk VPI:     --            
Routing Cost:          10                  Deroute delay time:    0 seconds     
                                                                                
Last Command: dsptrkcnf 4.1                                                     
                                                                                
hugo       TN    StrataCom       BPX 8620  9.2.37    Feb. 7 2001  16:22 GMT 
                                                                                
TRK 4.1 Parameters                                                              
 1 Q Depth - rt-VBR    [  202] (Dec)    15 Q Depth   - CBR     [  600] (Dec)    
 2 Q Depth - Non-TS    [  300] (Dec)    16 Q Depth   - nrt-VBR [ 1000] (Dec)    
 3 Q Depth - TS        [ 1000] (Dec)    17 Q Depth   - ABR     [ 8978] (Dec)    
 4 Q Depth - BData A   [ 1000] (Dec)    18 Low  CLP  - CBR     [ 100] (%)       
 5 Q Depth - BData B   [ 8000] (Dec)    19 High CLP  - CBR     [ 100] (%)       
 6 Q Depth - High Pri  [ 1000] (Dec)    20 Low  CLP  - nrt-VBR [ 100] (%)       
 7 Max Age - rt-VBR    [   20] (Dec)    21 High CLP  - nrt-VBR [ 100] (%)       
 8 Red Alm - I/O (Dec) [  2500 /  15000]22 Low CLP/EPD-ABR     [  60] (%)       
 9 Yel Alm - I/O (Dec) [  2500 /  15000]23 High CLP  - ABR     [  80] (%)       
10 Low  CLP - BData A  [ 100] (%)       24 EFCN      - ABR     [  30] (%)       
11 High CLP - BData A  [ 100] (%)       25 SVC Queue Pool Size [    0] (Dec)    
12 Low  CLP - BData B  [  25] (%)                                               
13 High CLP - BData B  [  75] (%)                                               
14 EFCN     - BData B  [  30] (Dec)                                             
                                                                                
This Command: cnftrkparm 4.1 

BXM-T3

hugo       TN    StrataCom       BPX 8620  9.2.37    Feb. 7 2001  16:22 GMT 
                                                                                
TRK  5.1 Config     T3     [96000 cps]     BXM slot:     5                      
Transmit Rate:         96000               VPC Conns disabled:    No            
Protocol By The Card:  No                  Line framing:          PLCP          
VC Shaping:            No                       coding:           --            
Hdr Type NNI:          Yes                      recv impedance:   --            
Statistical Reserve:   1000    cps              cable type:       --            
Idle code:             7F hex                         length:     0-225 ft.     
Connection Channels:   256                 Pass sync:             No            
Traffic:V,TS,NTS,FR,FST,CBR,N&RT-VBR,ABR   Loop clock:            No            
SVC Vpi Min:           0                   HCS Masking:           Yes           
SVC Channels:          0                   Payload Scramble:      No            
SVC Bandwidth:         0      cps          Frame Scramble:        --            
Restrict CC traffic:   No                  Virtual Trunk Type:    --            
Link type:             Terrestrial         Virtual Trunk VPI:     --            
Routing Cost:          10                  Deroute delay time:    0 seconds     
                                                                                
Last Command: dsptrkcnf 5.1                                                     
                                                                                
hugo       TN    StrataCom       BPX 8620  9.2.37    Feb. 7 2001  16:22 GMT 
                                                                                
TRK 5.1 Parameters                                                              
 1 Q Depth - rt-VBR    [  242] (Dec)    15 Q Depth   - CBR     [  400] (Dec)    
 2 Q Depth - Non-TS    [  360] (Dec)    16 Q Depth   - nrt-VBR [ 5000] (Dec)    
 3 Q Depth - TS        [ 1000] (Dec)    17 Q Depth   - ABR     [10000] (Dec)    
 4 Q Depth - BData A   [ 8000] (Dec)    18 Low  CLP  - CBR     [  60] (%)       
 5 Q Depth - BData B   [ 8000] (Dec)    19 High CLP  - CBR     [  80] (%)       
 6 Q Depth - High Pri  [ 1000] (Dec)    20 Low  CLP  - nrt-VBR [  60] (%)       
 7 Max Age - rt-VBR    [   20] (Dec)    21 High CLP  - nrt-VBR [  80] (%)       
 8 Red Alm - I/O (Dec) [  2500 /  15000]22 Low CLP/EPD-ABR     [  60] (%)       
 9 Yel Alm - I/O (Dec) [  2500 /  15000]23 High CLP  - ABR     [  80] (%)       
10 Low  CLP - BData A  [ 100] (%)       24 EFCN      - ABR     [  20] (%)       
11 High CLP - BData A  [ 100] (%)       25 SVC Queue Pool Size [    0] (Dec)    
12 Low  CLP - BData B  [  25] (%)                                               
13 High CLP - BData B  [  75] (%)                                               
14 EFCN     - BData B  [  30] (Dec)                                             
                                                                                
This Command: cnftrkparm 5.1 

BXM-OC12

hugo       TN    StrataCom       BPX 8620  9.2.37    Feb. 7 2001  16:22 GMT 
                                                                                
TRK  6.1 Config     OC12   [1412679cps]    BXM slot:     6                      
Transmit Rate:         1412830             VPC Conns disabled:    No            
Protocol By The Card:  No                  Line framing:          STS-12C       
VC Shaping:            No                       coding:           --            
Hdr Type NNI:          Yes                      recv impedance:   --            
Statistical Reserve:   1000    cps              cable type:       --            
Idle code:             7F hex                         length:     --            
Connection Channels:   256                 Pass sync:             No            
Traffic:V,TS,NTS,FR,FST,CBR,N&RT-VBR,ABR   Loop clock:            No            
SVC Vpi Min:           0                   HCS Masking:           Yes           
SVC Channels:          0                   Payload Scramble:      Yes           
SVC Bandwidth:         0      cps          Frame Scramble:        Yes           
Restrict CC traffic:   No                  Virtual Trunk Type:    --            
Link type:             Terrestrial         Virtual Trunk VPI:     --            
Routing Cost:          10                  Deroute delay time:    0 seconds     
                                                                                
Last Command: dsptrkcnf 6.1                                                     
                                                                                
                                                                                
hugo       TN    StrataCom       BPX 8620  9.2.37    Feb. 7 2001  16:23 GMT 
                                                                                
TRK 6.1 Parameters                                                              
 1 Q Depth - rt-VBR    [ 3533] (Dec)    15 Q Depth   - CBR     [ 1200] (Dec)    
 2 Q Depth - Non-TS    [ 5297] (Dec)    16 Q Depth   - nrt-VBR [10000] (Dec)    
 3 Q Depth - TS        [ 1000] (Dec)    17 Q Depth   - ABR     [40000] (Dec)    
 4 Q Depth - BData A   [40000] (Dec)    18 Low  CLP  - CBR     [  60] (%)       
 5 Q Depth - BData B   [40000] (Dec)    19 High CLP  - CBR     [  80] (%)       
 6 Q Depth - High Pri  [ 1000] (Dec)    20 Low  CLP  - nrt-VBR [  60] (%)       
 7 Max Age - rt-VBR    [   20] (Dec)    21 High CLP  - nrt-VBR [  80] (%)       
 8 Red Alm - I/O (Dec) [  2500 /  10000]22 Low CLP/EPD-ABR     [  60] (%)       
 9 Yel Alm - I/O (Dec) [  2500 /  10000]23 High CLP  - ABR     [  80] (%)       
10 Low  CLP - BData A  [ 100] (%)       24 EFCN      - ABR     [  20] (%)       
11 High CLP - BData A  [ 100] (%)       25 SVC Queue Pool Size [    0] (Dec)    
12 Low  CLP - BData B  [  25] (%)                                               
13 High CLP - BData B  [  75] (%)                                               
14 EFCN     - BData B  [  30] (Dec)                                             
                                                                                
This Command: cnftrkparm 6.1                                                    

BNI-155-OCS

hugo       TN    StrataCom       BPX 8620  9.2.37    Feb. 7 2001  16:23 GMT 
                                                                                
TRK 11.1 Config     OC3    [353207cps]     BNI-155 slot: 11                     
Transmit Rate:         353208              VPC Conns disabled:    --            
Protocol By The Card:  --                  Line framing:          STS-3C        
VC Shaping:            --                       coding:           --            
Hdr Type NNI:          --                       recv impedance:   --            
Statistical Reserve:   1000    cps              cable type:       --            
Idle code:             7F hex                         length:     --            
Connection Channels:   16050               Pass sync:             No            
Traffic:V,TS,NTS,FR,FST,CBR,N&RT-VBR,ABR   Loop clock:            No            
SVC Vpi Min:           --                  HCS Masking:           Yes           
SVC Channels:          0                   Payload Scramble:      Yes           
SVC Bandwidth:         0      cps          Frame Scramble:        Yes           
Restrict CC traffic:   No                  Virtual Trunk Type:    --            
Link type:             Terrestrial         Virtual Trunk VPI:     --            
Routing Cost:          10                  Deroute delay time:    0 seconds     
                                                                                
Last Command: dsptrkcnf 11.1                                                    
                                                                                
hugo       TN    StrataCom       BPX 8620  9.2.37    Feb. 7 2001  16:23 GMT 
                                                                                
TRK 11.1 Parameters                                                             
 1 Q Depth - rt-VBR    [  885] (Dec)    15 Q Depth   - CBR     [  600] (Dec)    
 2 Q Depth - Non-TS    [ 1324] (Dec)    16 Q Depth   - nrt-VBR [ 1000] (Dec)    
 3 Q Depth - TS        [ 1000] (Dec)    17 Q Depth   - ABR     [15463] (Dec)    
 4 Q Depth - BData A   [ 1000] (Dec)    18 Low  CLP  - CBR     [ 100] (%)       
 5 Q Depth - BData B   [ 8000] (Dec)    19 High CLP  - CBR     [ 100] (%)       
 6 Q Depth - High Pri  [ 1000] (Dec)    20 Low  CLP  - nrt-VBR [ 100] (%)       
 7 Max Age - rt-VBR    [   20] (Dec)    21 High CLP  - nrt-VBR [ 100] (%)       
 8 Red Alm - I/O (Dec) [  2500 /  10000]22 Low CLP/EPD-ABR     [  60] (%)       
 9 Yel Alm - I/O (Dec) [  2500 /  10000]23 High CLP  - ABR     [  80] (%)       
10 Low  CLP - BData A  [ 100] (%)       24 EFCN      - ABR     [  30] (%)       
11 High CLP - BData A  [ 100] (%)       25 SVC Queue Pool Size [    0] (Dec)    
12 Low  CLP - BData B  [  25] (%)                                               
13 High CLP - BData B  [  75] (%)                                               
14 EFCN     - BData B  [  30] (Dec)                                             
                                                                                
This Command: cnftrkparm 11.1                                                   


BXM-E3

                                                                                
hugo       TN    StrataCom       BPX 8620  9.2.37    Feb. 7 2001  16:23 GMT 
                                                                                
TRK 12.1 Config     E3     [80000 cps]     BXM slot:     12                     
Transmit Rate:         80000               VPC Conns disabled:    No            
Protocol By The Card:  No                  Line framing:          --            
VC Shaping:            No                       coding:           --            
Hdr Type NNI:          Yes                      recv impedance:   --            
Statistical Reserve:   1000    cps              cable type:       --            
Idle code:             7F hex                         length:     0-225 ft.     
Connection Channels:   256                 Pass sync:             No            
Traffic:V,TS,NTS,FR,FST,CBR,N&RT-VBR,ABR   Loop clock:            No            
SVC Vpi Min:           0                   HCS Masking:           Yes           
SVC Channels:          0                   Payload Scramble:      Yes           
SVC Bandwidth:         0      cps          Frame Scramble:        --            
Restrict CC traffic:   No                  Virtual Trunk Type:    --            
Link type:             Terrestrial         Virtual Trunk VPI:     --            
Routing Cost:          10                  Deroute delay time:    0 seconds     
                                                                                
Last Command: dsptrkcnf 12.1                                                    
                                                                                
hugo       TN    StrataCom       BPX 8620  9.2.37    Feb. 7 2001  16:23 GMT 
                                                                                
TRK 12.1 Parameters                                                             
 1 Q Depth - rt-VBR    [  202] (Dec)    15 Q Depth   - CBR     [  400] (Dec)    
 2 Q Depth - Non-TS    [  300] (Dec)    16 Q Depth   - nrt-VBR [ 5000] (Dec)    
 3 Q Depth - TS        [ 1000] (Dec)    17 Q Depth   - ABR     [10000] (Dec)    
 4 Q Depth - BData A   [ 8000] (Dec)    18 Low  CLP  - CBR     [  60] (%)       
 5 Q Depth - BData B   [ 8000] (Dec)    19 High CLP  - CBR     [  80] (%)       
 6 Q Depth - High Pri  [ 1000] (Dec)    20 Low  CLP  - nrt-VBR [  60] (%)       
 7 Max Age - rt-VBR    [   20] (Dec)    21 High CLP  - nrt-VBR [  80] (%)       
 8 Red Alm - I/O (Dec) [  2500 /  15000]22 Low CLP/EPD-ABR     [  60] (%)       
 9 Yel Alm - I/O (Dec) [  2500 /  15000]23 High CLP  - ABR     [  80] (%)       
10 Low  CLP - BData A  [ 100] (%)       24 EFCN      - ABR     [  20] (%)       
11 High CLP - BData A  [ 100] (%)       25 SVC Queue Pool Size [    0] (Dec)    
12 Low  CLP - BData B  [  25] (%)                                               
13 High CLP - BData B  [  75] (%)                                               
14 EFCN     - BData B  [  30] (Dec)                                             
                                                                                
This Command: cnftrkparm 12.1                                                   

IGX 8400 Nodes

mulder         TN    StrataCom       IGX 8420  9.2.37    Feb. 7 2001  16:56 GMT 
                                                                                
                           System-Wide Parameters                               
                                                                                
1  Max Time Stamped Packet Age (msec) ................................   32     
2  Allow CPU Starvation of Fail Handler ..............................   No     
3  Max Network Delay for 'v' connections (msec).......................   14     
4  Max Network Delay for 'c' connections (msec).......................   27     
5  Max Network Delay for 't' & 'p' connections (msec).................   14     
6  Max Network Delay for 'a' connections (msec).......................   27     
7  Max Network Delay for High Speed Data connections (msec)...........   32     
8  Max Network Delay for CDP-CDP 'v' connections (msec)...............   64     
9  Max Network Delay for CDP-CDP 'c' connections (msec)...............   64     
10 Max Network Delay for CDP-CDP 't' & 'p' connections (msec).........   64     
11 Max Network Delay for CDP-CDP 'a' connections (msec)..............    64                                                                                                                
12 Max Network Delay for CDP-CDP High Speed Data connections (msec)...   64     
13 Enable Discard Eligibility.........................................   No     
14 Use Frame Relay Standard Parameters Bc and Be......................   No     
15 Max Local Delay for Interdom CDP-CDP 'v' conns (msec)..............   27     
16 Max Local Delay for Interdom CDP-CDP 'c' conns (msec)..............   27     
17 Max Local Delay for Interdom CDP-CDP 't' & 'p' conns (msec)........   27     
18 Max Local Delay for Interdom CDP-CDP 'a' conns (msec)..............   27     
19 Max Local Delay for Interdom CDP-CDP High Speed Data conns (msec)..   27     
20 Max Local Delay for Interdom High Speed Data conns (msec)..........   28     
21 FastPAD Jitter Buffer Size  (msec).................................   15     
22 Number of Consecutive Invalid Login Attempts to Cause Major Alarm .    0                                 
23 Enable Connection Deroute Delay feature ...........................   No     
24 Interval Statstics polling rate for ATM/Frame Relay VCs............    5     
25 Interval Statistics polling rate for ports.........................    5     
                                                                                                                                                                                                                      
                                                                                
This Command: cnfsysparm                                                        
                                                                                
mulder         TN    StrataCom       IGX 8420  9.2.37    Feb. 7 2001  16:56 GMT 
                                                                                
1  Update Initial Delay   [ 5000] (D)   16 CC Redundancy Cnfged   [    Y] (Y/N) 
2  Update Per-Node Delay  [30000] (D)   17 MT3 Pass Through Relay [    Y] (Y/N) 
3  Comm-Break Test Delay  [30000] (D)   18 Nw Pkt Tx Rate (pps)   [  500] (D)   
4  Comm-Break Test Offset [   10] (D)   19 Stats Memory (x 100KB) [  130] (D)   
5  Network Timeout Period [ 1700] (D)   20 Standby Update Timer   [   10] (D)   
6  Network Inter-p Period [ 4000] (D)   21 Stby Updts Per Pass    [   50] (D)   
7  NW Sliding Window Size [    1] (D)   22 Gateway ID Timer       [   30] (D)   
8  Num Normal Timeouts    [    7] (D)   23 GLCON Alloc Timer      [   30] (D)   
9  Num Inter-p Timeouts   [    3] (D)   24 Comm Fail Delay        [   60] (D)   
10 Num Satellite Timeouts [    6] (D)   25 Nw Hdlr Timer (msec)   [  100] (D)   
11 Num Blind Timeouts     [    4] (D)   26 CBUS Delay (msec)      [   20] (D)   
12 Num CB Msg Timeouts    [    2] (D)   27 SNMP Event logging     [    Y] (Y/N) 
13 Comm Fail Interval     [10000] (D)   28 TFTP Grant Delay (sec) [    1] (D)   
14 Comm Fail Multiplier   [    3] (D)   29 TFTP ACK Timeout (sec) [   10] (D)   
15 Temperature Threshold  [   50] (D)   30 TFTP Write Retries     [    3] (D)   
                                                                                
31 FRP Link Status Alarm  [    Y] (Y/N) 46 Modem polling timer    [    1] (D)   
32 Job Lock Timeout       [36558] (D)   47 Verify CBA for non-FRP [    N] (Y/N) 
33 Max Via LCONs          [20000] (D)   48 Send Abit early        [    N] (Y/N) 
34 Max Blind Segment Size [ 3570] (D)   49 Abit Tmr Multiplier  M [    0] (D)   
35 Max XmtMemBlks per NIB [ 3000] (D)   50 Abit Tmr Granularity N [    3] (D)   
36 Max Mem on Stby Q (%)  [   33] (D)                                           
37 Trk Cell Rtng Restrict [    Y] (Y/N)                                         
38 Stat Config Proc Cnt   [ 1000] (D)                                           
39 Stat Config Proc Delay [ 2000] (D)                                           
40 Enable Degraded Mode   [    Y] (Y/N)                                         
41 Enable Rrt on Comm Fail[    N] (Y/N)                                         
42 Auto Switch on Degrade [    Y] (Y/N)                                         
43 Max Degraded Aborts    [  100] (D)                                           
44 Max Htls Rebuild Count [  100] (D)                                           
45 Htls Counter Reset Time[ 1000] (D)                                           
                                                                                
This Command: cnfnodeparm                                                       
                                                                                
mulder         TN    StrataCom       IGX 8420  9.2.37    Feb. 7 2001  16:57 GMT 
                                                                                
Index Status    Function                                                        
                                                                                
1     Enabled   Automatic CLN/PLN Loopback Test on Local/Remote Alarms          
2     Enabled   FDP Loopback button                                             
3     Enabled   User Command Logging                                            
4     Enabled   Automatic Card Reset on Hardware Error                          
5     Enabled   TXR Model D Download                                            
6     Enabled   Card Error Record Wraparound                                    
7     Disabled  Card Test After Failure                                         
8     Disabled  Download From Remote Cisco StrataView Plus                      
9     Disabled  Logging of conn events in local event log                       
10    Disabled  Logging of conn events in Cisco StrataView Plus event log       
11    Disabled  Logging SVC Connection Events                                   
12    Disabled  Force Download From a Specific IP address                       
13    Disabled  CDP WinkStart Signalling                                                                           
14    Enabled   Logging of Bus Diagnostic Events in local event log             
15    Enabled   Automatic Card Reset after Burnfw for CBI cards                 
                                                                                                                                                        
                                                                                
                                                                                
This Command: cnffunc                                                           
                                                                                

mulder         TN    StrataCom       IGX 8420  9.2.37    Feb. 7 2001  16:57 GMT 
                                                                                
Index Status    Function                                                        
                                                                                
1     Disabled  Data Frame Multiplexing                                         
2     Disabled  Adaptive Voice                                                  
3     Enabled   Frame Relay                                                     
4     Disabled  Configuration Save/Restore                                      
5     Disabled  ForeSight                                                       
6     Disabled  Frame Relay Network-to-Network Interface                        
7     Disabled  Multiple VTs (1 session enabled)                                
8     Disabled  Interface Shelf                                                 
9     Enabled   Virtual Trunks                                                  
10    Disabled  ABR standard with VSVD                                          
                                                                                                                                             
                                                                                
This Command: cnfswfunc                                                         
                                                                                

mulder         TN    StrataCom       IGX 8420  9.2.37    Feb. 7 2001  16:57 GMT 
                                                                                
Card   Test    - - - - - - Self Test - - - - - - -   - - Background Test - - -  
Type   Freq    Enable        Inc   Thresh  Timeout   Enable        Inc   Thresh 
----   -----   --------  -------  -------  -------   --------  -------  ------- 
PSM      300   Enabled       100      300       31   N/A           100      300 
HDM      300   Enabled       100      300       80   Enabled       100      300 
LDM      300   Enabled       100      300       80   Enabled       100      300 
NTM      300   Enabled       100      300       31   N/A           100      300 
FRM      300   Enabled       100      300       80   Enabled       100      300 
MT3      300   Enabled       100      300       50   N/A           100      300 
CVM      300   Enabled       100      300      300   N/A           100      300 
NPM      180   Enabled       100      300      120   N/A           100      300 
ARM      300   Enabled       100      300       60   N/A           100      300 
BTM      300   Enabled       100      300      120   N/A           100      300 
FTM      300   Enabled       100      300       80   Disabled      100      300 
UFM      300   Enabled       100      300       80   Enabled       100      300 
                                                                                
This Command: cnftstparm                                                        
                                                                                

mulder         TN    StrataCom       IGX 8420  9.2.37    Feb. 7 2001  16:57 GMT 
                                                                                
Card   Test    - - - - - - Self Test - - - - - - -   - - Background Test - - -  
Type   Freq    Enable        Inc   Thresh  Timeout   Enable        Inc   Thresh 
----   -----   --------  -------  -------  -------   --------  -------  ------- 
UFMU     300   Enabled       100      300       80   Enabled       100      300 
ALM      300   Enabled       100      300      120   N/A           100      300 
UVM      300   Disabled      100      300       60   N/A           100      300 
UXM      300   Enabled       100      300      800   Enabled       100      300 
                                                                                                                                                                                                            
                                                                                
This Command: cnftstparm                                                        
                                                                                
mulder         TN    StrataCom       IGX 8420  9.2.37    Feb. 7 2001  16:57 GMT 
                                                                                
1  Normalization Interval    [    2] (D)                                        
2  Max Number To Normalize   [    5] (D)                                        
3  Normalization Logging     [   No]                                            
4  Settling Interval         [    4] (D)                                        
5  Minimum Open Space        [ 1000] (D)                                        
6  Normalization Priority    [ Load]                                            
7  Load Sample Period        [    4] (D)                                        
8  Maximum Routing Bundle    [   90] (D)                                        
9  Reroute Timer             [    0] (secs)                                     
10 Reset Timer on Line Fail  [  Yes]                                            
11 Max Down/Up Per Pass      [   50] (D)                                        
12 Down/Up Timer             [30000] (msecs)                                    
13 Max Route Errs per cycle  [  200] (D)                                        
14 Time between Rrt cycles   [    5] (mins)                                     
15 Max. Rrt Err cycles       [    1] (D)                                                                                         
16 Routing pause timer       [    0] (msecs)                                    
17 Max msgs sent per update  [   10] (D)                                        
18 Send SVC urgent msg       [  Yes]                                            
19 Max SVC Retry             [    0] (D)                                        
20 Wait for TBL Updates      [   70] (100 msecs)                                
21 Max Derouting Bndl (0=all)[  500] (D)                                        
22 Enable Cost-Based Routing [   No]                                            
23 Enable Route Cache Usage  [   No]                                            
24 Use Delay for Routing     [   No]                                            
25 # of reroute groups used  [   50] (D)                                        
26 Starting size of RR grps  [    0] (CLU)                                      
27 Increment between RR grps [  100] (CLU)                                      
                                                                                                                                                     
                                                                                
This Command: cnfcmparm                                                         
                                                                                
mulder         TN    StrataCom       IGX 8420  9.2.37    Feb. 7 2001  16:58 GMT 
                                                                                
1  Rmt Blk Freq (msec)     [    100]    16 FW Dnld Msgs/Block(dec) [      4]    
2  Rmt Blk Size (hex)      [    400]    17 Flash Write TO(msec)    [  16000]    
3  Lcl Blk Freq (msec)     [    100]    18 Flash Erase TO(msec)    [    100]    
4  Lcl Blk Size (hex)      [    400]    19 Erase Verify TO(msec)   [  16000]    
5  Image Req Freq (msec)   [  10000]    20 Standby Flash TO(sec)   [    300]    
6  Dnld Req Freq (msec)    [  10000]    21 Lcl Flash Init TO(msec) [   1000]    
7  Session Timeout (msec)  [  30000]    22 Flsh Write Blk Sz (hex) [  10000]    
8  Request Hop Limit (dec) [      1]    23 Flsh Verfy Blk Sz (hex) [    400]    
9  Crc Throttle Freq (dec) [   5000]    24 Chips Per Write/Erase   [      1]    
10 Crc Block Size (hex)    [    400]                                            
11 Rev Change Wait(dec)    [      0]                                            
12 CCs Switch Wait(dec)    [   1000]                                            
13 Lcl Response TO(msec)   [   5000]                                            
14 Rmt Response TO(msec)   [  30000]                                            
15 FW Dnld Block TO(msec)  [     50]                                            
                                                                                
This Command: cnfdlparm                                                         
                                                                                

mulder         TN    StrataCom       IGX 8420  9.2.37    Feb. 7 2001  16:58 GMT 
                                                                                
1. Logout Time ........... 20 minutes                                           
2. VT Logout Time ........ 4 minutes                                            
3. Prompt Time ........... 60 seconds                                           
4. Command Time .......... 3 minutes                                            
5. UID Privilege Level ... 6                                                    
6. Input Character Echo .. Enabled                                              
7. Screen Update Time .... 10 seconds                                           
                                                                                
                                                                  
                                                                                
This Command: cnfuiparm                                                         
                                                                                

mulder         TN    StrataCom       IGX 8420  9.2.37    Feb. 7 2001  16:58 GMT 
                                                                                
Function            Number   Status      Function            Number   Status    
Background Upcard     1      Enabled     Dynamic BW Allocation 15     Enabled   
Background Updates    2      Disabled    Modem Polling         16     Enabled   
Standby Terminal      3      Disabled    Conn Stat Sampling    17     Enabled   
Memory Protection     4      Enabled     SVC Del Bgnd Updates  18     Disabled  
Comm Break            5      Enabled     FastPAD Test          19     Enabled   
Comm Fail Test        6      Enabled     Neighbor Update Errs  20     Disabled  
BRAM Memory Protect   7      Enabled                                            
CRC Test              8      Enabled                                            
CDT Clock Test        9      Enabled                                            
Bus Fail Detection    10     Enabled                                            
Line Diag             11     Enabled                                            
Clock Restoral        12     Enabled                                            
Cm_Rerouting          13     Enabled                                            
Clock Routing         14     Enabled                                            
                                                                                
This Command: on1                                                               
                                                                                
mulder         TN    StrataCom       IGX 8420  9.2.37    Feb. 7 2001  16:58 GMT 
                                                                                
Function            Number   Status      Function            Number   Status    
Line Stat Sampling    1      Enabled     LAN Interface         15     Enabled   
Statistical Alarm     2      Enabled     Update Standby Stats  16     Enabled   
Job Ready Checker     3      Enabled     EIA Monitoring        17     Enabled   
Configuration  Backup 4      Enabled     Telnet Access         18     Enabled   
Standby Update        5      Enabled     Junction ID           19     Enabled   
Downloader            6      Enabled     Mult SV+/Routing Node 20     Enabled   
Cm Updates            7      Enabled     Feeder with NW Trunks 21     Disabled  
Power Supply Monitor  8      Enabled     Multiple Fdr Trunks   22     Disabled  
Topo/Stat Updates     9      Enabled     Simulated Fdr Trks    23     Disabled  
CDP/CIP Sig. Polling  10     Enabled     Auto Renum Fail Recov 24     Enabled   
Port Stat Sampling    11     Enabled     IGX - ACM Selftest    25     Enabled   
Robust Updates        12     Enabled     Card Simulation Tool  26     Enabled   
Robust Alarm Updates  13     Enabled     Major Alarm on NNI    27     Disabled  
Realtime Counters     14     Enabled     Deroute Delay         28     Enabled   
                                                                                
This Command: on2                               
                                
                                                                                
mulder         TN    StrataCom       IGX 8420  9.2.37    Feb. 7 2001  16:58 GMT 
                                                                                
Function            Number   Status                                             
Region memory init    1      Disabled                                           
Trace Msg Sent        2      Disabled                                           
Multi-DB Stby Updates 3      Enabled                                            
AIT/BTM/ALM 32h Ext2  4      Enabled                                            
Card Synchronization  5      Disabled                                           
Loop Access Dev Init  6      Disabled                                           
Auto allocate UXM UBU 7      Disabled                                           
Trace Conv Msg        8      Disabled                                           
Automatic Cbus Diags  9      Disabled                                           
CBUS Flood Protection 10     Enabled                                            
                                                                                
                                                                                
This Command: on3                                                               
                                                                              

NTM-E1

                                                                                
mulder         TN    StrataCom       IGX 8420  9.2.37    Feb. 7 2001  16:59 GMT 
                                                                                
TRK  3 Config         E1/32    [10666 pps]  NTM slot:3                          
Line DS-0 map:        0-31                                                      
Pass sync:            Yes                                                       
Loop clock:           No                                                        
Statistical Reserve:  600    pps                                                
Routing Cost:         10                                                        
Idle code:            54 hex                                                    
Restrict PCC traffic: No                                                        
Link type:            Terrestrial                                               
Line coding:          HDB3                                                      
Line CRC:             No                                                        
Line recv impedance:  75 ohm + gnd                                              
Traffic:              V,TS,NTS,FR,FST                                           
Deroute delay time:   0 seconds                                                 
                                                                                
                                                                                
Last Command: dsptrkcnf 3                                                       
                                                                                
                                                                                

mulder         TN    StrataCom       IGX 8420  9.2.37    Feb. 7 2001  16:59 GMT 
                                                                                
TRK  3 Parameters:                                                              
 1 Yel Alm-In/Out (D)  [  1000/  2000]     18 Red Alm-In/Out (D) [  1000/  2000]
 2 Rx Max Age - rt-VBR   (D)   [  N/A]     19 Tx Max Age - rt-VBR   (D)  [   20]
 3 Rx EFCN  - BdataB     (D)   [  N/A]     20 Tx EFCN    - BdataB   (D)  [   30]
 4 Gateway Efficiency    (D)   [  N/A]                                          
 5 EFCN     - Rx Space   (D)   [  N/A]     Tx Age Step2  (D)   Tx Age Step   (D)
 6 Low CLP  - Rx_Space   (%)   [  N/A]     21 BDataA [  128]   23 BDataA [  128]
 7 High CLP - Rx_Space   (%)   [  N/A]     22 BDataB [  128]   24 BDataB [  128]
Rx High CLP   (%)    Rx Low CLP    (%)     Tx High CLP   (%)   Tx Low CLP    (%)
 8 BDataA [  N/A]    10 BDataA [  N/A]     25 BDataA [  100]   27 BDataA [  100]
 9 BDataB [  N/A]    11 BdataB [  N/A]     26 BDataB [   75]   28 BDataB [   25]
Receive Queue Depth                (D)     Transmit Queue Depth              (D)
12 rt-VBR [  N/A]    15 BDataA [  N/A]     29 rt-VBR [   28]   32 BDataA [  600]
13 Non TS [  N/A]    16 BDataB [  N/A]     30 Non TS [   40]   33 BDataB [  600]
14 TS     [  N/A]    17 HighPri[  N/A]     31 TS     [ 2632]   34 HighPri[  100]
                                                                                
This Command: cnftrkparm 3                                                      
                                                                                

NTM-T1

mulder         TN    StrataCom       IGX 8420  9.2.37    Feb. 7 2001  16:59 GMT 
                                                                                
TRK  4 Config         T1/24    [8000  pps]  NTM slot:4                          
Line DS-0 map:        0-23                                                      
Pass sync:            Yes                                                       
Loop clock:           No                                                        
Statistical Reserve:  600    pps                                                
Routing Cost:         10                                                        
Idle code:            7F hex                                                    
Restrict PCC traffic: No                                                        
Link type:            Terrestrial                                               
Line framing:         D4                                                        
Line coding:          B8ZS                                                      
Line cable type:      ABAM                                                      
Line cable length:    0-133 ft.                                                 
Traffic:              V,TS,NTS,FR,FST                                           
Deroute delay time:   0 seconds                                                 
                                                                                
Last Command: dsptrkcnf 4                                                       
                                                                              
mulder         TN    StrataCom       IGX 8420  9.2.37    Feb. 7 2001  16:59 GMT 
                                                                                
TRK  4 Parameters:                                                              
 1 Yel Alm-In/Out (D)  [   600/   600]     18 Red Alm-In/Out (D) [  2500/ 15000]
 2 Rx Max Age - rt-VBR   (D)   [  N/A]     19 Tx Max Age - rt-VBR   (D)  [   20]
 3 Rx EFCN  - BdataB     (D)   [  N/A]     20 Tx EFCN    - BdataB   (D)  [   30]
 4 Gateway Efficiency    (D)   [  N/A]                                          
 5 EFCN     - Rx Space   (D)   [  N/A]     Tx Age Step2  (D)   Tx Age Step   (D)
 6 Low CLP  - Rx_Space   (%)   [  N/A]     21 BDataA [  128]   23 BDataA [  128]
 7 High CLP - Rx_Space   (%)   [  N/A]     22 BDataB [  128]   24 BDataB [  128]
Rx High CLP   (%)    Rx Low CLP    (%)     Tx High CLP   (%)   Tx Low CLP    (%)
 8 BDataA [  N/A]    10 BDataA [  N/A]     25 BDataA [  100]   27 BDataA [  100]
 9 BDataB [  N/A]    11 BdataB [  N/A]     26 BDataB [   75]   28 BDataB [   25]
Receive Queue Depth                (D)     Transmit Queue Depth              (D)
12 rt-VBR [  N/A]    15 BDataA [  N/A]     29 rt-VBR [   22]   32 BDataA [  600]
13 Non TS [  N/A]    16 BDataB [  N/A]     30 Non TS [   30]   33 BDataB [  600]
14 TS     [  N/A]    17 HighPri[  N/A]     31 TS     [ 2648]   34 HighPri[  100]
                                                                                
This Command: cnftrkparm 4                                                      
 

NTM-SR

mulder         TN    StrataCom       IGX 8420  9.2.37    Feb. 7 2001  16:59 GMT 
                                                                                
TRK  5 Config         SR/30    [10000 pps]  NTM slot:5                          
Subrate interface:    X.21                                                      
Subrate data rate:    1920 kbps                                                 
Pass sync:            No                                                        
Loop clock:           Yes                                                       
Statistical Reserve:  600    pps                                                
Routing Cost:         10                                                        
Restrict PCC traffic: No                                                        
Link type:            Terrestrial                                               
Traffic:              V,TS,NTS,FR,FST                                           
Deroute delay time:   0 seconds                                                 
                                                                                                                                                                                                                                                                                                                            
                                                                                
Last Command: dsptrkcnf 5                                                       
                                                                                                                                                              

mulder         TN    StrataCom       IGX 8420  9.2.37    Feb. 7 2001  16:59 GMT 
                                                                                
TRK  5 Parameters:                                                              
 1 Yel Alm-In/Out (D)  [  1000/  2000]     18 Red Alm-In/Out (D) [  1000/  2000]
 2 Rx Max Age - rt-VBR   (D)   [  N/A]     19 Tx Max Age - rt-VBR   (D)  [   20]
 3 Rx EFCN  - BdataB     (D)   [  N/A]     20 Tx EFCN    - BdataB   (D)  [   30]
 4 Gateway Efficiency    (D)   [  N/A]                                          
 5 EFCN     - Rx Space   (D)   [  N/A]     Tx Age Step2  (D)   Tx Age Step   (D)
 6 Low CLP  - Rx_Space   (%)   [  N/A]     21 BDataA [  128]   23 BDataA [  128]
 7 High CLP - Rx_Space   (%)   [  N/A]     22 BDataB [  128]   24 BDataB [  128]
Rx High CLP   (%)    Rx Low CLP    (%)     Tx High CLP   (%)   Tx Low CLP    (%)
 8 BDataA [  N/A]    10 BDataA [  N/A]     25 BDataA [  100]   27 BDataA [  100]
 9 BDataB [  N/A]    11 BdataB [  N/A]     26 BDataB [   75]   28 BDataB [   25]
Receive Queue Depth                (D)     Transmit Queue Depth              (D)
12 rt-VBR [  N/A]    15 BDataA [  N/A]     29 rt-VBR [   27]   32 BDataA [  600]
13 Non TS [  N/A]    16 BDataB [  N/A]     30 Non TS [   37]   33 BDataB [  600]
14 TS     [  N/A]    17 HighPri[  N/A]     31 TS     [ 2636]   34 HighPri[  100]
                                                                                
This Command: cnftrkparm 5                                                      
                                                                                

mulder         TN    StrataCom       IGX 8420  9.2.37    Feb. 7 2001  16:59 GMT 
                                                                                
TRK  6.1 Config       OC3      [353207cps]  UXM slot:6                          
Transmit Trunk Rate:  353208 cps          Connection Channels:  256             
Rcv Trunk Rate:       353207 cps          Gateway Channels:     200             
Pass sync:            Yes                 Traffic:V,TS,NTS,FR,FST,CBR,N&RVBR,ABR
Loop clock:           No                  Frame Scramble:       Yes             
Statistical Reserve:  1000   cps          Deroute delay time:   0 seconds       
Header Type:          NNI                 VC Shaping:           No              
VPI Address:          1                   VPC Conns disabled:   No              
Routing Cost:         10                                                        
Idle code:            7F hex                                                    
Restrict PCC traffic: No                                                        
Link type:            Terrestrial                                               
Line framing:         STM-1                                                     
HCS Masking:          Yes                                                       
Payload Scramble:     Yes                                                       
                                                                                
Last Command: dsptrkcnf 6.1                                                     
                                                                                

mulder         TN    StrataCom       IGX 8420  9.2.37    Feb. 7 2001  17:00 GMT 
                                                                                
TRK  6.1 Parameters:                                                            
 1 Yel Alm-In/Out (D)  [  2500/ 10000]     18 Red Alm-In/Out (D) [  2500/ 10000]
 2 Rx Max Age - rt-VBR   (D)   [   20]     19 Tx Max Age - rt-VBR   (D)  [   20]
 3 Rx EFCN  - BdataB     (D)   [   20]     20 Tx EFCN    - BdataB   (%)  [   20]
 4 Gateway Efficiency    (D)   [  2.0]                                          
 5 EFCN     - Rx Space   (D)   [  N/A]     Tx Age Step2  (D)   Tx Age Step   (D)
 6 Low CLP/EPD- Rx_Space (%)   [  N/A]     21 BDataA [  N/A]   23 BDataA [  N/A]
 7 High CLP - Rx_Space   (%)   [  N/A]     22 BDataB [  N/A]   24 BDataB [  N/A]
Rx High CLP   (%)    Rx Low CLP/EPD(%)     Tx High CLP   (%)   Tx Low CLP/EPD(%)
 8 BDataA [   80]    10 BDataA [   60]     25 BDataA [   80]   27 BDataA [   60]
 9 BDataB [   80]    11 BdataB [   60]     26 BDataB [   80]   28 BDataB [   60]
Receive Queue Depth                (D)     Transmit Queue Depth              (D)
12 rt-VBR [ 1952]    15 BDataA [10000]     29 rt-VBR [ 1952]   32 BDataA [10000]
13 Non TS [ 2925]    16 BDataB [10000]     30 Non TS [ 2925]   33 BDataB [10000]
14 TS     [ 1000]    17 HighPri[ 1000]     31 TS     [ 1000]   34 HighPri[ 1000]
                                                                                
This Command: cnftrkparm 6.1                                                    
                                                                                                                                                             
TRK  6.1 Parameters: 
                                                           
Rx Queue Depth(D)    Tx Queue Depth(D)    Rx EFCN       (%)    Tx EFCN       (%)
35 CBR    [  600]    38 CBR    [  600]                                          
36 nrt-VBR[ 5000]    39 nrt-VBR[ 5000]                                          
37 ABR    [20000]    40 ABR    [20000]    47 ABR    [   20]    48 ABR    [   20]
Rx High CLP   (%)    Rx Low CLP/EPD(%)    Tx High CLP   (%)    Tx Low CLP/EPD(%)
41 CBR    [   80]    44 CBR    [   60]    49 CBR    [   80]    52 CBR    [   60]
42 nrt-VBR[   80]    45 nrt-VBR[   60]    50 nrt-VBR[   80]    53 nrt-VBR[   60]
43 ABR    [   80]    46 ABR    [   60]    51 ABR    [   80]    54 ABR    [   60]
                                                                                
                                                            
                                                                                                                                                               
                                                                                
This Command: cnftrkparm 6.1                                                    
                                                                                

UXM-E3

mulder         TN    StrataCom       IGX 8420  9.2.37    Feb. 7 2001  17:00 GMT 
                                                                                
TRK  7.1 Config       E3/530   [80000 cps]  UXM slot:7                          
Transmit Trunk Rate:  80000  cps          Payload Scramble:     Yes             
Rcv Trunk Rate:       80000  cps          Connection Channels:  256             
Pass sync:            Yes                 Gateway Channels:     200             
Loop clock:           No                  Traffic:V,TS,NTS,FR,FST,CBR,N&RVBR,ABR
Statistical Reserve:  1000   cps          Deroute delay time:   0 seconds       
Header Type:          NNI                 VC Shaping:           No              
VPI Address:          1                   VPC Conns disabled:   No              
Routing Cost:         10                                                        
Idle code:            7F hex                                                    
Restrict PCC traffic: No                                                        
Link type:            Terrestrial                                               
Line framing:         HEC                                                       
Line cable length:    0-225 ft.                                                 
HCS Masking:          Yes                                                       
                                                                                
Last Command: dsptrkcnf 7.1                                                     
                                                                                

mulder         TN    StrataCom       IGX 8420  9.2.37    Feb. 7 2001  17:00 GMT 
                                                                                
TRK  7.1 Parameters:                                                            
 1 Yel Alm-In/Out (D)  [  2500/ 15000]     18 Red Alm-In/Out (D) [  2500/ 15000]
 2 Rx Max Age - rt-VBR   (D)   [   20]     19 Tx Max Age - rt-VBR   (D)  [   20]
 3 Rx EFCN  - BdataB     (D)   [   20]     20 Tx EFCN    - BdataB   (%)  [   20]
 4 Gateway Efficiency    (D)   [  2.0]                                          
 5 EFCN     - Rx Space   (D)   [  N/A]     Tx Age Step2  (D)   Tx Age Step   (D)
 6 Low CLP/EPD- Rx_Space (%)   [  N/A]     21 BDataA [  N/A]   23 BDataA [  N/A]
 7 High CLP - Rx_Space   (%)   [  N/A]     22 BDataB [  N/A]   24 BDataB [  N/A]
Rx High CLP   (%)    Rx Low CLP/EPD(%)     Tx High CLP   (%)   Tx Low CLP/EPD(%)
 8 BDataA [   80]    10 BDataA [   60]     25 BDataA [   80]   27 BDataA [   60]
 9 BDataB [   80]    11 BdataB [   60]     26 BDataB [   80]   28 BDataB [   60]
Receive Queue Depth                (D)     Transmit Queue Depth              (D)
12 rt-VBR [  443]    15 BDataA [10000]     29 rt-VBR [  443]   32 BDataA [10000]
13 Non TS [  662]    16 BDataB [10000]     30 Non TS [  662]   33 BDataB [10000]
14 TS     [ 1000]    17 HighPri[ 1000]     31 TS     [ 1000]   34 HighPri[ 1000]
                                                                                
This Command: cnftrkparm 7.1                                                    
                                                                                

mulder         TN    StrataCom       IGX 8420  9.2.37    Feb. 7 2001  17:00 GMT 
                                                                                
TRK  7.1 Parameters:                                                            
Rx Queue Depth(D)    Tx Queue Depth(D)    Rx EFCN       (%)    Tx EFCN       (%)
35 CBR    [  600]    38 CBR    [  600]                                          
36 nrt-VBR[ 5000]    39 nrt-VBR[ 5000]                                          
37 ABR    [20000]    40 ABR    [20000]    47 ABR    [   20]    48 ABR    [   20]
Rx High CLP   (%)    Rx Low CLP/EPD(%)    Tx High CLP   (%)    Tx Low CLP/EPD(%)
41 CBR    [   80]    44 CBR    [   60]    49 CBR    [   80]    52 CBR    [   60]
42 nrt-VBR[   80]    45 nrt-VBR[   60]    50 nrt-VBR[   80]    53 nrt-VBR[   60]
43 ABR    [   80]    46 ABR    [   60]    51 ABR    [   80]    54 ABR    [   60]
                                                                                
                                                  
                                                                                
This Command: cnftrkparm 7.1                                                    


UXM-T1

mulder         TN    StrataCom       IGX 8420  9.2.37    Feb. 7 2001  17:00 GMT 
                                                                                
TRK  8.1 Config       T1/24    [3622  cps]  UXM slot:8                          
IMA Group Member(s):  1                   Line coding:          B8ZS            
Retained links:       1                   Line cable type:      ABAM            
Transmit Trunk Rate:  3622   cps          Line cable length:    0-131 ft.       
Rcv Trunk Rate:       3622   cps          HCS Masking:          Yes             
Pass sync:            Yes                 Payload Scramble:     No              
Loop clock:           No                  Connection Channels:  256             
Statistical Reserve:  600    cps          Gateway Channels:     200             
Header Type:          NNI                 Traffic:V,TS,NTS,FR,FST,CBR,N&RVBR,ABR
VPI Address:          1                   IMA Protocol Option:  Disabled        
Routing Cost:         10                  IMA Max. Diff. Dly:   200 msec.       
Idle code:            7F hex              IMA Clock Mode:       CTC             
Restrict PCC traffic: No                  Deroute delay time:   0 seconds       
Link type:            Terrestrial         VC Shaping:           No              
Line framing:         ESF                 VPC Conns disabled:   No              
                                                                                
Last Command: dsptrkcnf 8.1                                                     
                                                                                
                                                                                
Next Command: dsptrkcnf 8.1                                                     
                                                                                
mulder         TN    StrataCom       IGX 8420  9.2.37    Feb. 7 2001  17:00 GMT 
                                                                                
TRK  8.1 Parameters:                                                            
 1 Yel Alm-In/Out (D)  [   600/   600]     18 Red Alm-In/Out (D) [  2500/ 15000]
 2 Rx Max Age - rt-VBR   (D)   [   20]     19 Tx Max Age - rt-VBR   (D)  [   20]
 3 Rx EFCN  - BdataB     (D)   [   20]     20 Tx EFCN    - BdataB   (%)  [   20]
 4 Gateway Efficiency    (D)   [  2.0]                                          
 5 EFCN     - Rx Space   (D)   [  N/A]     Tx Age Step2  (D)   Tx Age Step   (D)
 6 Low CLP/EPD- Rx_Space (%)   [  N/A]     21 BDataA [  N/A]   23 BDataA [  N/A]
 7 High CLP - Rx_Space   (%)   [  N/A]     22 BDataB [  N/A]   24 BDataB [  N/A]
Rx High CLP   (%)    Rx Low CLP/EPD(%)     Tx High CLP   (%)   Tx Low CLP/EPD(%)
 8 BDataA [   80]    10 BDataA [   60]     25 BDataA [   80]   27 BDataA [   60]
 9 BDataB [   80]    11 BdataB [   60]     26 BDataB [   80]   28 BDataB [   60]
Receive Queue Depth                (D)     Transmit Queue Depth              (D)
12 rt-VBR [   22]    15 BDataA [10000]     29 rt-VBR [   21]   32 BDataA [10000]
13 Non TS [   30]    16 BDataB [10000]     30 Non TS [   28]   33 BDataB [10000]
14 TS     [ 1000]    17 HighPri[ 1000]     31 TS     [ 1000]   34 HighPri[ 1000]
                                                                                
This Command: cnftrkparm 8.1                                                    

mulder         TN    StrataCom       IGX 8420  9.2.37    Feb. 7 2001  17:00 GMT 
                                                                                
TRK  8.1 Parameters:                                                            
Rx Queue Depth(D)    Tx Queue Depth(D)    Rx EFCN       (%)    Tx EFCN       (%)
35 CBR    [  600]    38 CBR    [  600]                                          
36 nrt-VBR[ 5000]    39 nrt-VBR[ 5000]                                          
37 ABR    [20000]    40 ABR    [20000]    47 ABR    [   20]    48 ABR    [   20]
Rx High CLP   (%)    Rx Low CLP/EPD(%)    Tx High CLP   (%)    Tx Low CLP/EPD(%)
41 CBR    [   80]    44 CBR    [   60]    49 CBR    [   80]    52 CBR    [   60]
42 nrt-VBR[   80]    45 nrt-VBR[   60]    50 nrt-VBR[   80]    53 nrt-VBR[   60]
43 ABR    [   80]    46 ABR    [   60]    51 ABR    [   80]    54 ABR    [   60]
                                                         
                                                                                
                                                                                
                                                                                
This Command: cnftrkparm 8.1                                                    
                                                                                

UXM-E1/30

mulder         TN    StrataCom       IGX 8420  9.2.37    Feb. 7 2001  17:00 GMT 
                                                                                
TRK  9.1 Config       E1/30    [4528  cps]  UXM slot:9                          
Line DS-0 map:        1-15,17-31          Line coding:          HDB3            
IMA Group Member(s):  1                   Line CRC:             Yes             
Retained links:       1                   Line recv impedance:  120 ohm         
Transmit Trunk Rate:  4528   cps          HCS Masking:          Yes             
Rcv Trunk Rate:       4528   cps          Payload Scramble:     Yes             
Pass sync:            Yes                 Connection Channels:  256             
Loop clock:           No                  Gateway Channels:     200             
Statistical Reserve:  600    cps          Traffic:V,TS,NTS,FR,FST,CBR,N&RVBR,ABR
Header Type:          NNI                 IMA Protocol Option:  Disabled        
VPI Address:          1                   IMA Max. Diff. Dly:   200 msec.       
Routing Cost:         10                  IMA Clock Mode:       CTC             
Idle code:            54 hex              Deroute delay time:   0 seconds       
Restrict PCC traffic: No                  VC Shaping:           No              
Link type:            Terrestrial         VPC Conns disabled:   No              
                                                                                
Last Command: dsptrkcnf 9.1                                                     
                                                                                

mulder         TN    StrataCom       IGX 8420  9.2.37    Feb. 7 2001  17:01 GMT 
                                                                                
TRK  9.1 Parameters:                                                            
 1 Yel Alm-In/Out (D)  [  1000/  2000]     18 Red Alm-In/Out (D) [  1000/  2000]
 2 Rx Max Age - rt-VBR   (D)   [   20]     19 Tx Max Age - rt-VBR   (D)  [   20]
 3 Rx EFCN  - BdataB     (D)   [   20]     20 Tx EFCN    - BdataB   (%)  [   20]
 4 Gateway Efficiency    (D)   [  N/A]                                          
 5 EFCN     - Rx Space   (D)   [  N/A]     Tx Age Step2  (D)   Tx Age Step   (D)
 6 Low CLP/EPD- Rx_Space (%)   [  N/A]     21 BDataA [  N/A]   23 BDataA [  N/A]
 7 High CLP - Rx_Space   (%)   [  N/A]     22 BDataB [  N/A]   24 BDataB [  N/A]
Rx High CLP   (%)    Rx Low CLP/EPD(%)     Tx High CLP   (%)   Tx Low CLP/EPD(%)
 8 BDataA [   80]    10 BDataA [   60]     25 BDataA [   80]   27 BDataA [   60]
 9 BDataB [   80]    11 BdataB [   60]     26 BDataB [   80]   28 BDataB [   60]
Receive Queue Depth                (D)     Transmit Queue Depth              (D)
12 rt-VBR [   27]    15 BDataA [10000]     29 rt-VBR [   26]   32 BDataA [10000]
13 Non TS [   37]    16 BDataB [10000]     30 Non TS [   36]   33 BDataB [10000]
14 TS     [ 1000]    17 HighPri[ 1000]     31 TS     [ 1000]   34 HighPri[ 1000]
                                                                                
This Command: cnftrkparm 9.1                                                    
                                                                                
                                                                                
mulder         TN    StrataCom       IGX 8420  9.2.37    Feb. 7 2001  17:01 GMT 
                                                                                
TRK  9.1 Parameters:                                                            
Rx Queue Depth(D)    Tx Queue Depth(D)    Rx EFCN       (%)    Tx EFCN       (%)
35 CBR    [  600]    38 CBR    [  600]                                          
36 nrt-VBR[ 5000]    39 nrt-VBR[ 5000]                                          
37 ABR    [20000]    40 ABR    [20000]    47 ABR    [   20]    48 ABR    [   20]
Rx High CLP   (%)    Rx Low CLP/EPD(%)    Tx High CLP   (%)    Tx Low CLP/EPD(%)
41 CBR    [   80]    44 CBR    [   60]    49 CBR    [   80]    52 CBR    [   60]
42 nrt-VBR[   80]    45 nrt-VBR[   60]    50 nrt-VBR[   80]    53 nrt-VBR[   60]
43 ABR    [   80]    46 ABR    [   60]    51 ABR    [   80]    54 ABR    [   60]
                                                                                                                                                      
                                                                                
                                                                                
                                                                                
This Command: cnftrkparm 9.1                                                    


BTM-T3

mulder         TN    StrataCom       IGX 8420  9.2.37    Feb. 7 2001  17:01 GMT 
                                                                                
TRK 11 Config         T3/3     [1000  pps]  BTM slot:11                         
Transmit Trunk Rate:  96000  cps          HCS Masking:          Yes             
Rcv Trunk Rate:       1000   pps          Payload Scramble:     No              
Pass sync:            Yes                 Traffic:              V,TS,NTS,FR,FST 
Loop clock:           No                  Deroute delay time:   0 seconds       
Statistical Reserve:  1000   pps                                                
Header Type:          STI                                                       
Gateway Type:         BAM                                                       
VPI Address:          0                                                         
VCI Address:          0                                                         
Routing Cost:         10                                                        
Idle code:            7F hex                                                    
Restrict PCC traffic: No                                                        
Link type:            Terrestrial                                               
Line cable length:    0-225 ft.                                                 
                                                                                
Last Command: dsptrkcnf 11                                                      
                                                                                
mulder         TN    StrataCom       IGX 8420  9.2.37    Feb. 7 2001  17:01 GMT 
                                                                                
TRK 11 Parameters:                                                              
 1 Yel Alm-In/Out (D)  [  2500/ 15000]     18 Red Alm-In/Out (D) [  2500/ 15000]
 2 Rx Max Age - rt-VBR   (D)   [   20]     19 Tx Max Age - rt-VBR   (D)  [   20]
 3 Rx EFCN  - BdataB     (D)   [   30]     20 Tx EFCN    - BdataB   (D)  [   30]
 4 Gateway Efficiency    (D)   [  2.0]                                          
 5 EFCN     - Rx Space   (D)   [   30]     Tx Age Step2  (D)   Tx Age Step   (D)
 6 Low CLP  - Rx_Space   (%)   [  100]     21 BDataA [  N/A]   23 BDataA [  N/A]
 7 High CLP - Rx_Space   (%)   [  100]     22 BDataB [  N/A]   24 BDataB [  N/A]
Rx High CLP   (%)    Rx Low CLP    (%)     Tx High CLP   (%)   Tx Low CLP    (%)
 8 BDataA [  100]    10 BDataA [  100]     25 BDataA [  100]   27 BDataA [  100]
 9 BDataB [   75]    11 BdataB [   25]     26 BDataB [   75]   28 BDataB [   25]
Receive Queue Depth                (D)     Transmit Queue Depth              (D)
12 rt-VBR [    4]    15 BDataA [ 2264]     29 rt-VBR [  532]   32 BDataA [ 2264]
13 Non TS [    3]    16 BDataB [ 2264]     30 Non TS [  795]   33 BDataB [ 2264]
14 TS     [11365]    17 HighPri[  100]     31 TS     [10045]   34 HighPri[  100]
                                                                                
This Command: cnftrkparm 11                                                     
                                                                                
                                                                                

BTM-E3

mulder         TN    StrataCom       IGX 8420  9.2.37    Feb. 7 2001  17:01 GMT 
                                                                                
TRK 12 Config         E3/3     [1000  pps]  BTM slot:12                         
Transmit Trunk Rate:  80000  cps          HCS Masking:          Yes             
Rcv Trunk Rate:       1000   pps          Payload Scramble:     Yes             
Pass sync:            Yes                 Traffic:              V,TS,NTS,FR,FST 
Loop clock:           No                  Deroute delay time:   0 seconds       
Statistical Reserve:  1000   pps                                                
Header Type:          STI                                                       
Gateway Type:         BAM                                                       
VPI Address:          0                                                         
VCI Address:          0                                                         
Routing Cost:         10                                                        
Idle code:            7F hex                                                    
Restrict PCC traffic: No                                                        
Link type:            Terrestrial                                               
Line cable length:    0-225 ft.                                                 
                                                                                
Last Command: dsptrkcnf 12                                                      
                                                                                

mulder         TN    StrataCom       IGX 8420  9.2.37    Feb. 7 2001  17:01 GMT 
                                                                                
TRK 12 Parameters:                                                              
 1 Yel Alm-In/Out (D)  [  2500/ 15000]     18 Red Alm-In/Out (D) [  2500/ 15000]
 2 Rx Max Age - rt-VBR   (D)   [   20]     19 Tx Max Age - rt-VBR   (D)  [   20]
 3 Rx EFCN  - BdataB     (D)   [   30]     20 Tx EFCN    - BdataB   (D)  [   30]
 4 Gateway Efficiency    (D)   [  2.0]                                          
 5 EFCN     - Rx Space   (D)   [   30]     Tx Age Step2  (D)   Tx Age Step   (D)
 6 Low CLP  - Rx_Space   (%)   [  100]     21 BDataA [  N/A]   23 BDataA [  N/A]
 7 High CLP - Rx_Space   (%)   [  100]     22 BDataB [  N/A]   24 BDataB [  N/A]
Rx High CLP   (%)    Rx Low CLP    (%)     Tx High CLP   (%)   Tx Low CLP    (%)
 8 BDataA [  100]    10 BDataA [  100]     25 BDataA [  100]   27 BDataA [  100]
 9 BDataB [   75]    11 BdataB [   25]     26 BDataB [   75]   28 BDataB [   25]
Receive Queue Depth                (D)     Transmit Queue Depth              (D)
12 rt-VBR [    4]    15 BDataA [ 2264]     29 rt-VBR [  443]   32 BDataA [ 2264]
13 Non TS [    3]    16 BDataB [ 2264]     30 Non TS [  662]   33 BDataB [ 2264]
14 TS     [11365]    17 HighPri[  100]     31 TS     [10267]   34 HighPri[  100]
                                                                                
This Command: cnftrkparm 12                                                     
                                                                                
                                                                                

BTM-HSSI

mulder         TN    StrataCom       IGX 8420  9.2.37    Feb. 7 2001  17:01 GMT 
                                                                                
TRK 13 Config         HSSI/3   [1000  pps]  BTM slot:13                         
Clock Rate:           50840000 bps        Line cable length:    0-225 ft.       
Transmit Trunk Rate:  111491 cps          HCS Masking:          Yes             
Rcv Trunk Rate:       1000   pps          Payload Scramble:     No              
Pass sync:            No                  Traffic:              V,TS,NTS,FR,FST 
Loop clock:           No                  Deroute delay time:   0 seconds       
Statistical Reserve:  1000   pps                                                
Header Type:          STI                                                       
Gateway Type:         BAM                                                       
VPI Address:          0                                                         
VCI Address:          0                                                         
Routing Cost:         10                                                        
Idle code:            7F hex                                                    
Restrict PCC traffic: No                                                        
Link type:            Terrestrial                                               
                                                                                
Last Command: dsptrkcnf 13                                                      
                                                                                

mulder         TN    StrataCom       IGX 8420  9.2.37    Feb. 7 2001  17:02 GMT 
                                                                                
TRK 13 Parameters:                                                              
 1 Yel Alm-In/Out (D)  [  2500/ 15000]     18 Red Alm-In/Out (D) [  2500/ 15000]
 2 Rx Max Age - rt-VBR   (D)   [   20]     19 Tx Max Age - rt-VBR   (D)  [   20]
 3 Rx EFCN  - BdataB     (D)   [   30]     20 Tx EFCN    - BdataB   (D)  [   30]
 4 Gateway Efficiency    (D)   [  2.0]                                          
 5 EFCN     - Rx Space   (D)   [   30]     Tx Age Step2  (D)   Tx Age Step   (D)
 6 Low CLP  - Rx_Space   (%)   [  100]     21 BDataA [  N/A]   23 BDataA [  N/A]
 7 High CLP - Rx_Space   (%)   [  100]     22 BDataB [  N/A]   24 BDataB [  N/A]
Rx High CLP   (%)    Rx Low CLP    (%)     Tx High CLP   (%)   Tx Low CLP    (%)
 8 BDataA [  100]    10 BDataA [  100]     25 BDataA [  100]   27 BDataA [  100]
 9 BDataB [   75]    11 BdataB [   25]     26 BDataB [   75]   28 BDataB [   25]
Receive Queue Depth                (D)     Transmit Queue Depth              (D)
12 rt-VBR [    4]    15 BDataA [ 2264]     29 rt-VBR [  617]   32 BDataA [ 2264]
13 Non TS [    3]    16 BDataB [ 2264]     30 Non TS [  922]   33 BDataB [ 2264]
14 TS     [11365]    17 HighPri[  100]     31 TS     [ 9833]   34 HighPri[  100]
                                                                                
This Command: cnftrkparm 13                                                     
                                                                                

UXM-T1

mulder         TN    StrataCom       IGX 8420  9.2.37    Feb. 7 2001  17:13 GMT 
                                                                                
TRK  8.4 Config       T1/24    [3622  cps]  UXM slot:8                          
IMA Group Member(s):  4                   Line coding:          B8ZS            
Retained links:       1                   Line cable type:      ABAM            
Transmit Trunk Rate:  3622   cps          Line cable length:    0-131 ft.       
Rcv Trunk Rate:       3622   cps          HCS Masking:          Yes             
Pass sync:            Yes                 Payload Scramble:     No              
Loop clock:           No                  Connection Channels:  256             
Statistical Reserve:  600    cps          Gateway Channels:     200             
Header Type:          NNI                 Traffic:V,TS,NTS,FR,FST,CBR,N&RVBR,ABR
VPI Address:          1                   IMA Protocol Option:  Disabled        
Routing Cost:         10                  IMA Max. Diff. Dly:   200 msec.       
Idle code:            7F hex              IMA Clock Mode:       CTC             
Restrict PCC traffic: No                  Deroute delay time:   0 seconds       
Link type:            Terrestrial         VC Shaping:           No              
Line framing:         ESF                 VPC Conns disabled:   No              
                                                                                
Last Command: dsptrkcnf 8.4                                                     
                                                                                

mulder         TN    StrataCom       IGX 8420  9.2.37    Feb. 7 2001  17:13 GMT 
                                                                                
TRK  8.4 Parameters:                                                            
 1 Yel Alm-In/Out (D)  [   600/   600]     18 Red Alm-In/Out (D) [  2500/ 15000]
 2 Rx Max Age - rt-VBR   (D)   [   20]     19 Tx Max Age - rt-VBR   (D)  [   20]
 3 Rx EFCN  - BdataB     (D)   [   20]     20 Tx EFCN    - BdataB   (%)  [   20]
 4 Gateway Efficiency    (D)   [  2.0]                                          
 5 EFCN     - Rx Space   (D)   [  N/A]     Tx Age Step2  (D)   Tx Age Step   (D)
 6 Low CLP/EPD- Rx_Space (%)   [  N/A]     21 BDataA [  N/A]   23 BDataA [  N/A]
 7 High CLP - Rx_Space   (%)   [  N/A]     22 BDataB [  N/A]   24 BDataB [  N/A]
Rx High CLP   (%)    Rx Low CLP/EPD(%)     Tx High CLP   (%)   Tx Low CLP/EPD(%)
 8 BDataA [   80]    10 BDataA [   60]     25 BDataA [   80]   27 BDataA [   60]
 9 BDataB [   80]    11 BdataB [   60]     26 BDataB [   80]   28 BDataB [   60]
Receive Queue Depth                (D)     Transmit Queue Depth              (D)
12 rt-VBR [   22]    15 BDataA [10000]     29 rt-VBR [   21]   32 BDataA [10000]
13 Non TS [   30]    16 BDataB [10000]     30 Non TS [   28]   33 BDataB [10000]
14 TS     [ 1000]    17 HighPri[ 1000]     31 TS     [ 1000]   34 HighPri[ 1000]
                                                                                
This Command: cnftrkparm 8.4                                                    
                                                                                

mulder         TN    StrataCom       IGX 8420  9.2.37    Feb. 7 2001  17:14 GMT 
                                                                                
TRK  8.4 Parameters:                                                            
Rx Queue Depth(D)    Tx Queue Depth(D)    Rx EFCN       (%)    Tx EFCN       (%)
35 CBR    [  600]    38 CBR    [  600]                                          
36 nrt-VBR[ 5000]    39 nrt-VBR[ 5000]                                          
37 ABR    [20000]    40 ABR    [20000]    47 ABR    [   20]    48 ABR    [   20]
Rx High CLP   (%)    Rx Low CLP/EPD(%)    Tx High CLP   (%)    Tx Low CLP/EPD(%)
41 CBR    [   80]    44 CBR    [   60]    49 CBR    [   80]    52 CBR    [   60]
42 nrt-VBR[   80]    45 nrt-VBR[   60]    50 nrt-VBR[   80]    53 nrt-VBR[   60]
43 ABR    [   80]    46 ABR    [   60]    51 ABR    [   80]    54 ABR    [   60]
                                                                                                                                                                                                                          
This Command: cnftrkparm 8.4                                                    
 

UXM-E1

mulder         TN    StrataCom       IGX 8420  9.2.37    Feb. 7 2001  17:14 GMT 
                                                                                
TRK  9.4 Config       E1/30    [4528  cps]  UXM slot:9                          
Line DS-0 map:        1-15,17-31          Line coding:          HDB3            
IMA Group Member(s):  4                   Line CRC:             Yes             
Retained links:       1                   Line recv impedance:  120 ohm         
Transmit Trunk Rate:  4528   cps          HCS Masking:          Yes             
Rcv Trunk Rate:       4528   cps          Payload Scramble:     Yes             
Pass sync:            Yes                 Connection Channels:  256             
Loop clock:           No                  Gateway Channels:     200             
Statistical Reserve:  600    cps          Traffic:V,TS,NTS,FR,FST,CBR,N&RVBR,ABR
Header Type:          NNI                 IMA Protocol Option:  Disabled        
VPI Address:          1                   IMA Max. Diff. Dly:   200 msec.       
Routing Cost:         10                  IMA Clock Mode:       CTC             
Idle code:            54 hex              Deroute delay time:   0 seconds       
Restrict PCC traffic: No                  VC Shaping:           No              
Link type:            Terrestrial         VPC Conns disabled:   No              
                                                                                
Last Command: dsptrkcnf 9.4                                                     
                                                                                

mulder         TN    StrataCom       IGX 8420  9.2.37    Feb. 7 2001  17:14 GMT 
                                                                                
TRK  9.4 Parameters:                                                            
 1 Yel Alm-In/Out (D)  [  1000/  2000]     18 Red Alm-In/Out (D) [  1000/  2000]
 2 Rx Max Age - rt-VBR   (D)   [   20]     19 Tx Max Age - rt-VBR   (D)  [   20]
 3 Rx EFCN  - BdataB     (D)   [   20]     20 Tx EFCN    - BdataB   (%)  [   20]
 4 Gateway Efficiency    (D)   [  N/A]                                          
 5 EFCN     - Rx Space   (D)   [  N/A]     Tx Age Step2  (D)   Tx Age Step   (D)
 6 Low CLP/EPD- Rx_Space (%)   [  N/A]     21 BDataA [  N/A]   23 BDataA [  N/A]
 7 High CLP - Rx_Space   (%)   [  N/A]     22 BDataB [  N/A]   24 BDataB [  N/A]
Rx High CLP   (%)    Rx Low CLP/EPD(%)     Tx High CLP   (%)   Tx Low CLP/EPD(%)
 8 BDataA [   80]    10 BDataA [   60]     25 BDataA [   80]   27 BDataA [   60]
 9 BDataB [   80]    11 BdataB [   60]     26 BDataB [   80]   28 BDataB [   60]
Receive Queue Depth                (D)     Transmit Queue Depth              (D)
12 rt-VBR [   27]    15 BDataA [10000]     29 rt-VBR [   26]   32 BDataA [10000]
13 Non TS [   37]    16 BDataB [10000]     30 Non TS [   36]   33 BDataB [10000]
14 TS     [ 1000]    17 HighPri[ 1000]     31 TS     [ 1000]   34 HighPri[ 1000]
                                                                                
This Command: cnftrkparm 9.4                                                    
                                                                                
                                                                                
mulder         TN    StrataCom       IGX 8420  9.2.37    Feb. 7 2001  17:14 GMT 
                                                                                
TRK  9.4 Parameters:                                                            
Rx Queue Depth(D)    Tx Queue Depth(D)    Rx EFCN       (%)    Tx EFCN       (%)
35 CBR    [  600]    38 CBR    [  600]                                          
36 nrt-VBR[ 5000]    39 nrt-VBR[ 5000]                                          
37 ABR    [20000]    40 ABR    [20000]    47 ABR    [   20]    48 ABR    [   20]
Rx High CLP   (%)    Rx Low CLP/EPD(%)    Tx High CLP   (%)    Tx Low CLP/EPD(%)
41 CBR    [   80]    44 CBR    [   60]    49 CBR    [   80]    52 CBR    [   60]
42 nrt-VBR[   80]    45 nrt-VBR[   60]    50 nrt-VBR[   80]    53 nrt-VBR[   60]
43 ABR    [   80]    46 ABR    [   60]    51 ABR    [   80]    54 ABR    [   60]
                                                                                                                                             
                                                                                
This Command: cnftrkparm 9.4 

Appendix A

BXM Firmware MEJ Release Notes

About the Firmware MEJ

BXM Firmware version MEJ supports all the existing interfaces and models of BXM hardware. Following table outlines various levels of hardware revisions supported for BXM firmware version MEF

Front Cards

Model Number  Description  FW Model  HW Rev  FW Rev 

BXM-155-4

4 port OC3 Line Module (Front Card)

E

B

MEJMEJ

BXM-155-8

8 port OC3 Line Module (Front Card)

E

B

MEJ

BXM-622

1 port OC12 Line Module (Front Card)

E

D

MEJ

BXM-622-2

2 port OC12 Line Module (Front Card)

E

D

MEJ

BXM-T3-8

8 port T3 Line Module (Front Card)

E

B

MEJ

BXM-T3-12

12 port T3 Line Module (Front Card)

E

B

MEJ

BXM-E3-8

8 port E3 Line Module (Front Card)

E

B

MEJ

BXM-E3-12

12 port E3 Line Module (Front Card)

E

B

MEJ

BXM-155-8DX

8 port OC3 Line Module (Front Card)

E

A0

MEJ

BXM-155-8D

8 port OC3 Line Module (Front Card)

E

A0

MEJ

BXM-155-4DX

4 port OC3 Line Module (Front Card)

E

A0

MEJ

BXM-155-4D

4 port OC3 Line Module (Front Card)

E

A0

MEJ

BXM-622-2DX

2 port OC12 Line Module (Front Card)

E

A0

MEJ

BXM-622-2D

2 port OC12 Line Module (Front Card)

E

A0

MEJ

BXM-622-DX

1 port OC12 Line Module (Front Card)

E

A0

MEJ

BXM-T3-12EX

12 port T3 Line Module (Front Card)

E

A0

MEJ

BXM-T3-12E

12 port T3 Line Module (Front Card)

E

A0

MEJ

BXM-T3-8E

8 port T3 Line Module (Front Card)

E

A0

MEJ

BXM-E3-12EX

12 port E3 Line Module (Front Card)

E

A0

MEJ

BXM-E3-12E

12 port E3 Line Module (Front Card)

E

A0

MEJ

BXM-E3-8E

8 port E3 Line Module (Front Card)

E

A0

MEJ

Front Card for APS Compatibility

Model Number  Description  FW Model  HW Rev  FW Rev 

BXM-155-4

4 port OC3 Line Module (Front Card)

E

C

MEJ

BXM-155-8

8 port OC3 Line Module (Front Card)

E

C

MEJ

BXM-622

1 port OC12 Line Module (Front Card)

E

E

MEJ

BXM-622-2

2 port OC12 Line Module (Front Card)

E

E

MEJ

BXM-155-8DX

8 port OC3 Line Module (Front Card)

E

A0

MEJ

BXM-155-8D

8 port OC3 Line Module (Front Card)

E

A0

MEJ

BXM-155-4DX

4 port OC3 Line Module (Front Card)

E

A0

MEJ

BXM-155-4D

4 port OC3 Line Module (Front Card)

E

A0

MEJ

BXM-622-2DX

2 port OC12 Line Module (Front Card)

E

A0

MEJ

BXM-622-2D

2 port OC12 Line Module (Front Card)

E

A0

MEJ

BXM-622-DX

1 port OC12 Line Module (Front Card)

E

A0

MEJ

Back Cards

Model Number  Description  HW Rev  FW Rev 

MMF-155-4

4 port multi-mode fiber back card

A

na

MMF-155-8

8 port multi-mode fiber back card

A

na

SMF-155-4

4 port single-mode fiber intermediate-reach back card

A

na

SMF-155-8

8 port single-mode fiber intermediate-reach back card

A

na

SMFLR-155-4

4 port single-mode fiber long-reach back card

A

na

SMFLR-155-8

4 port single-mode fiber long-reach back card

A

na

SMF-622

1 port intermediate-reach OC12 back card

A

na

SMF-622-2

2 port intermediate-reach OC12 back card

A

na

SMFLR-622

1 port long-reach OC12 back card

A

na

SMFLR-622-2

2 port long-reach OC12 back card

A

na

XLR-622

1 port extra long-reach OC12 back card

A

na

XLR-622-2

2 port extra long-reach OC12 back card

A

na

BPX-T3/E3-12

12 port T3/E3 back card

A

na

BPX-T3/E3-8

8 port T3/E3 back card

A

na

RDNT-LR-622-2

2 port long-reach OC12 redundant back card

A

na

RDNT-SM-622-2

2 port intermediate reach OC12 redundant back cards

A

na

RDNT-SM-622

1 port intermediate reach OC12 redundant back cards

A

na

RDNT-LR-155-8

8 port long-reach OC3 redundant back cards

A

na

RDNT-SM-155-4

4 port intermediate-reach OC3 redundant back cards

A

na

RDNT-SM-155-8

8 port intermediate-reach OC3 redundant back cards

A

na

New Features Supported in BXM Firmware MEJ

New Features Supported in BXM Firmware MEH

New Features Supported in BXM Firmware MEF

There is no new feature in release MEF

New Features Supported in BXM Firmware MEE

There is no new feature in release MEE

New Features Supported in BXM Firmware MED

There is no new feature in release MED

New Features Supported in BXM Firmware MEC

There is no new feature in release MEC

New Features Supported in BXM Firmware MEB

There is no new feature in release MEB

New Features Supported in BXM Firmware MEA

1. VSI version 2.2 (single partition)

2. ITUT Annex B and configurable Signal Degrade (SD) and Signal Failure (SF) thresholds for SONET Linear APS on BXM-OC3 and BXM-OC12 (1+1, 2 card, 1:1).

The current default thresholds are as follows:

BIP count  Condition 

10^-4

SF detected

10^-5

SD detected & SF clear

10^-6

SD clear & SF clear

New Features Supported in BXM Firmware MDA

1. Support for Virtual Trunking

2. Support for BXM Multi-Level Channel Statistics

3. SONET Linear APS on BXM-OC3 and BXM-OC12 (1+1, 2 card, 1:1)

4. Support for card based LMI and ILMI

Clarifications

1. The OC-3 MultiMode Fiber backcards do not support Y-cable redundancy.

2. Upgrade from VSI 1.1 to VSI 2.2 is supported in this release. See upgrade section on page 9.

Special Installation/Upgrade Requirements

BXM cards with M.C.B/M.D.A firmware or later can be smoothly migrated to the M.E.H version of firmware by using y-cable redundancy. To upgrade a BXM card pair in y-red configuration, first upgrade the standby card with the MEJ firmware version and wait for all the configuration to be downloaded into the card. Do a switchyred to switch to the card with firmware M.E.F and burn the other card also with M.E.H firmware. Follow the standard firmware upgrade procedure for downloading and burning the firmware into the cards.

Features Obsoleted

VSI 1.0 is obsoleted by VSI 2.2 in this release.

Notes and Cautions

1. M.E.E is fully compatible 9.2 Switch Software. It has not been tested for compatibility with 8.4, 8.5, or 9.1 Switch Software. It is compatible with IOS version 12.05t2 for MPLS

2. While upgrading firmware on OC3 or 2-port OC12 BXM cards whose statistics level is greater than 1 (command dspnovram "Number of Channel stats: shows 12 or higher"), the upgrade should take place according to one of the procedures below to avoid the card mismatch.

Upgrading from firmware revision MEA or higher:


Step 1   Switch software should be upgraded to 9.2.30 or higher.

Note Switch Software Release 9.1.x can be used with MEx firmware if VSI is not enabled.

Step 2   Upgrade the firmware to MEJ.



Upgrading from firmware revision lower than MEA:


Step 1   Firmware should be upgraded to MEC

Step 2   Upgrade the Switch Software to 9.2.30 or higher revision.

Note Switch Software Release 9.1.x can be used with MEx firmware if VSI is not enabled.

Step 3   Upgrade the firmware to MEJ.



3. Burn firmware should not be interrupted. Card resets in the middle of burn firmware will result in the BXM being maintained in the core state (Identified by blinking yellow LED), or failed state (Identified by a solid red led). In this case the dspcds screen will report the card as FAILED. This state can be recovered by reburning the firmware into the card.

4. Protection Switching based on BER on BXM may not comply to standards. The GR-253 & ITU-T G.783 requires that switching be completed within 60 msec from the time the error starts. BXM is unable to detect BER threshold crossing until the next poll, which occurs every 250 msec. Thus, switching time may be up to 250 msec under certain circumstances.

5. In APS 1+1 default configuration, both backcard LEDs show green when primary card is active and selection is from PROT line. When primary card is active and it is selecting from PROT, PROT backcard should be green, since it is carrying traffic. WORK backcard should also be green since that is the physical path for the primary (and active) card to pass traffic. So backcard LED green means the backcard is directly or indirectly carrying traffic and pulling the backcard will cause traffic disruption. (CSCdm53430)

6. In APS 1+1 default configuration and a manual W->P is on and a switchyred is issued, a manual W->P event is logged. By default, on switchyred the new active card comes up in "clear" state. But in this case since there is a manual W->P on, the APS line switches to PROT and the switching is logged. (CSCdm53404)

7. In APS 1+1 default configuration if the selected line is PROT and last user request is clear and a switchyred is issued, line switches to WORK. If the last user request is "clear", full automatic APS switching is in effect with the working line being active by default. When there is no last user switch request to switch to any particular line, the working line will become active. (CSCdm53420)

8. When APS Annex B is added to local end which has the Secondary card active, the APS trunk goes into Comm Failure for few seconds and then clears. If Secondary card is active, then do a switchyred to make Primary card active and then add APS Annex B. (CSCdm46359)

Known Anomalies

The following is the list of known anomalies for the BXM firmware.

Bug ID  Description 

CSCdp32247

Symptom: switchapsln/dsplog show no alarm at all but Popeye show alarms

Conditions:

CSCdp05098

Symptom: Cell discards occur for ABRFST/ABRSTD conns when the traffic burst is greater than the MBS

Condition: This occurs when the traffic burst size is fixed to 140000 cells at 70000 cps. The conn are configured with PCR=72000/72000, MBS=1000/1000 and ICR 7200/7200. This is the expected behavior since the configured MBS < the actual burst size.

Workaround: Increase the MBS and ICR using cnfcon.

Bugs Fixed in MEJ

The following bugs are fixed between MEH & MEJ.

Bug ID  Description 

CSCdr19696

Symptom: User never gets to know when the line is out of SD/SF condition.Both the aps lines always show in OK state in dspapsln.

Condition: APS Line switches to standby line because of SD/SF condition. dspapsln will still show OK for both the lines. This way, user will never get to know when this line has come out of SD/SF condition.

Workaround: Use rsh command to get all the aps line's status.

CSCdp87443

Symptom: The APS switch to working lines after finished burned FW.

Conditions:

Workaround: Upgrade to MEJ or newer version firmware

CSCdr55491

Symptom: Disconnect the working line of APS 1:1 lines will cause the active line is protective line and it is working fine after APS line switching.major alarm (Path Unavailable Secs.) on the trunk or line via this APS line pair.Also, the active APS line has the alarm "Path Unavailable" even the real.

Conditions: This problem only happens in 9.3 and APS 1:1 mode.

Workaround:

1. addapsln to APS 1:1 mode and uptrk or upln using upped APS line.

2. make sure the active line is working line, if not, switchapsln to manually switch it.

3. pull out the Rx cable of working line. the APS switching should happen.

4. the active line should be protective line after switching.

5. the "Active Line Alarm Status" is "Path Unavailable" and the trunk or line has major alarm "Path Unavailable Secs."

6. pull back the Rx cable of working line, alarms is gone.

CSCdp67775

Symptom: APS does not clear last user request after SF switch

Conditions: Jan. 1999 edition of GR-253-CORE (issue 2, Revision 2, section 5-92 which supersedes the document you are quoting)

Workaround: Upgrade to MEJ or newer version of firmware

Bugs Fixed in MEH

The following bugs are fixed between MEF & MEH.

Bug ID  Description 

CSCdp63445

Symptom: ABR and UBR connections loose traffic when VC shaping is turned on.

Condition: Enabling of VC shaping on port terminating ABR and UBR connections

Workaround: Leave VC shaping disabled.

CSCdp62213

Symptom: Switching from bi-direction to uni-direction mode APS generates APS architecture mismatch error

Condition: When APS pair is configured from bi-direction mode to uni-dir mode the other side indicates APS architecture mismatch error, and then the other side is also configured from bi-direction mode to uni-direction mode, the APS architecture mismatch error does not clear.

Workaround: delete APS and then add APS again - it defaults to uni-dir

CSCdp46399

Symptom: Need a documentation explains how to setup port groups for FW MEF (me26)

CSCdr11396

Symptom: All user data is dropped when send in 960 cps of OAM

Condition: Data transfer has affected while running OAM loopback

Workaround: Upgrade to MEH or newer version of firmware

CSCdr11511

Symptom: Different behavior for segment and end-to-end OAM loopback

Conditions:

Workaround: Upgrade to MEH or newer version of firmware

CSCdr13151

Symptom: dspportstats always show TX port=0

Conditions: sending in >= 960 cps of oam loopback cell

Workaround: Upgrade to MEH or newer version of firmware

CSCdr13182

Symptom: tstdelay fails for all PVCs when they are > 960 cps of OAM

Conditions: When user sending in >= 960 cps of oam loopback cells

Workaround: Upgrade to MEH or newer version of firmware

CSCdr13196

Symptom: Too many software error 105 when running OAM test

Conditions: Software error 105 logged while running OAM loopback test

Workaround: Upgrade to MEH or newer version of firmware

CSCdr13208

Symptom: Too many OAM cells causes CD errors

Conditions: One PVC has 2880 cps of data and 960 cps of oam cells and Another PVC has 2880 cps of data and 960 cps of oam cells,

Workaround: Upgrade to MEH or newer version of firmware

CSCdp09419

Symptom: Granularity of tstdelay is 17 ms

Conditions:

Workaround: Upgrade to MEH or newer version of firmware

CSCdr51875

Symptom: Virtual Trunking causing Unreachable

Conditions:

Workaround: Upgrade to MEH or newer version of firmware

Bugs Fixed in MEF

Bug ID  Description 

CSCdp58969

Symptom: cb_get.c CB_VPC_STATUS_POLL SoItcSend Failed upon VSI Failure

Condition: When VSI receives and transmits lot of VSI message AAL5 drive will get into deadlock problem if it had missed a DMA interrupt

Workaround: None. Upgrade to MEF or newer version of firmware

CSCdp57596

Symptom: CB_TASK on BXM goes into deadlock state causing VSI session to be lost

Condition: This happens when both Ingress and Egress qe semaphore is taken by IDLE_TASK and it never released in an error condition

Workaround:. None. Upgrade to MEF or newer versions of firmware.

CSCdp25220

Symptom: Avail Buffer on BXM = 0 on LVC flapping for xtag interfaces

Condition: Same as CSCdp58969. During this condition AAL5 driver doesn't release the transmission buffer.

Workaround: None. Upgrade to/MEF or newer versions of firmware

CSCdp59328

Symptom: EPD bit was not set for interslave control vc

Condition: When VSI get congestion (same as CSCdp58969)

Workaround:.None. Upgrade to/MEF or newer versions of firmware

CSCdp92916

Symptom: Commands executed on standby card affect APS line

Condition: Series of commands executed in standby card affects APS line

Workaround: None.Upgrade to MEF or newer version of firmware

CSCdp39723

Symptom: Aps not functioning in 9.2.21 w/FW ME18@sprintf for Bidirectional w/Nonrevertive

Condition: Reversion was happening due to spurious SF/SD events.Fixed by setting the right values for SF/SD thresholds

Workaround:None.Upgrade to MEF or newer version of firmware

CSCdp20848

Symptom: SF switchover does not occur after dncd/upcd execution on Annex B 1+1 APS

Condition: When the dncd command is executed, Switch Software sends 0x27 CBUS message. The handler for this message was putting the lines in loopback and shutting down the laser. Also it was changing the line state in SoCdDown() to DOWN state. This caused subsequent upcd (0x05/0x04) message to re-initialize the lines disabling the S/UNI interrupts in the process.

Workaround:None.Upgrade to MEF or newer version of firmware

CSCdp24224

Symptom: WTR does not occur after LOS recovery on protection line

Condition: The meaning of primary and secondary channels were changed immediately upon switchover instead of waiting for the expiry of WTR. This caused the clearing of the failure to be accounted against the secondary channel and thus there was no WTR. Fixed by introducing a Preparation switch mode where-in the current active channel will remain as the secondary until a WTR occurs or a primary section mismatch pre-empts that state. At the expiry of WTR, the preparation switch mode is complete and the current active channel becomes the primary.

Workaround:None.Upgrade to MEF or newer version of firmware

CSCdp32646

Symptom: WTR Timer does not work and reversion occurs during SF switchover

Condition: Added a preparation switch mode where the current active channel is the secondary channel. At the expiry of WTR, the secondary channel is changed to the become the primary channel.

Workaround: None.Upgrade to MEF or newer version of firmware

CSCdp35156

Symptom: BPX APS reverts back to the working line before WTR time has expired

Condition: TR was being pre-empted by a spurious SD condition. Fixed by setting the right thresholds for SF/SD based on BER

Workaround:None.Upgrade to MEF or newer version of firmware

CSCdp60696

Symptom: Both lines fail when only one line in alarm

Condition: After the standby card comes out of reset, its S/UNI states are not reliable for a period of 1.5 seconds and the S/UNI reports LOS clear on the WORK line. This gets conveyed to the active card and then the Manual switch gets priority and becomes the current local request. This causes a switch back to WORK. When the active card's S/UNI monitors the WORK line, it discovers that the line is in LOS and immediately switches back. The oscillations continue and the line goes into LOCKOUT due to excessive switching. In the Lockout mode only the WORK line is active and thus the defect.

Workaround:None.Upgrade to MEF or newer version of firmware

CSCdp65320

Symptom: Need a trap when BPX puts APS in lockout

Condition: Send the traps in the right sequence. First send the Lockout trap and then the failed to switch trap if there is a switch attempt while lockout is in effect.

Workaround:None.Upgrade to MEF or newer version of firmware

CSCdp25130

Symptom: APS Non-revertive bidirectional feature

Condition: Resolved

Workaround: None

CSCdp50624

Symptom: SVCs in progress get released when standby BXM is pulled

Condition: When the standby card reset, the pending number of tcbs agains grows more than 40 and retransmits to standby card for 2 seconds.Because of this master couldn't get response since no buffer and timeout.

Workaround:None.Upgrade to MEF or newer version of firmware

CSCdp79156

Symptom: TDP signalling cross connect VSI request rejected by BXM

Condition: If BPX is configured with trunks and virtual trunks the virtual trunks are initialized properly with qbin size.

Workaround:None.Upgrade to MEF or newer version of firmware

CSCdp62213

Symptom: Switching from bi-direction APS to un-directional APS generates mismatch err

Condition: The alarms generated while the line was in bi-dir mode was not cleared when it was changed to uni-dir mode. Fixed by clearing all alarms when re-configuring the lines.None.

Workaround:None.Upgrade to MEF or newer version of firmware

CSCdp89972

Symptom: Node rebuild caused 3 BXM cards failed

Condition: Moved the allocation and initialization of the Connection database to the SoCoEnterStandby function instead of in the 0x50 handler (SoCdUp)

Workaround:None.Upgrade to MEF or newer version of firmware

CSCdp86147

Symptom: The removal of Rx cable of APS trunk leading to loss of Frm and Prot Sw Byt Fail

Condition: While removing the Rx cable of APS working line (configured to trunk) working line goes to Loss of Frm and dsptrks shows the trunk in alarm. After connecting cable back the APS Alarm status shows "Prot Sw Byt FAIL"

Workaround:None.Upgrade to MEF or newer version of firmware

CSCdp84386

Symptom: Connectivity w/BXM lost due to missing DMA completion interrupts

Condition: Aal5 driver will be in deadlock and never transmits and receives.

Workaround:None.Upgrade to MEF or newer version of firmware

CSCdp38148

Symptom: Resetcd slot 11 on BPX causes local APS switching

Condition: re-impose the selector and bridge states on both ACTIVE and STANDBY cards after a Y-red switchover, re-discover the line states and re-execute and external requests.Also include a STABILITY timer before the line state is processed.

Workaround: None.Upgrade to MEF or newer version of firmware

CSCdm92931

Symptom: APS line switchover occurs up one card removal when lockout is set

Condition:

Workaround: None Upgrade to MEF or newer version of firmware

CSCdp49749

Symptom: node unreachable after resetting two nodes in the network

Condition:

Workaround: None

CSCdp49640

Symptom: When FCES feature enable on BXM NNI data transfer stops

Condition: The ABR parameters like NRM,CRM,FRTT,MCR,ICR were not getting programmed when the FCES is turned on using cnfcon command.Adding the Connection with the FCES enabled behaved properly.

Workaround: None

CSCdm62817

Symptom: tstconseg command sometimes does not work.

Condition: execute tstconseg multiple times with high loop count (10).

Workaround: None

CSCdm84853

Symptom: BW reported via interface load info is erroneous.

Condition: When Forward & Backward BW for VSI connections is different.

Workaround: None

The following bugs are fixed between MEE & MEF

Bugs Fixed in MEE

Bug ID  Description 

CSCdp40682

Symptom: BPX becomes un-reachable when slot 11 was active

Condition: Excessive APS switching occurs and node aborts when a software loopback is applied on an APS line with W and P cables pulled.

Workaround: Do not perform addlnlocrmtlp on an APS pair

CSCdp38148

Symptom: resetcd slot 11 on BPX causes local APS switch

Condition: When ACTIVE (and PRIMARY) card is monitoring the PROT line and STANDBY (and SECONDARY) card is monitoring WORK line, if the ACTIVE card is reset, then the SECONDARY card comes up as active and switches to WORK line by default

Workaround:. None. Upgrade to MED or newer versions of firmware.

CSCdp25220

Symptom: APS K2 bytes do not have the right info

Condition: When BPX APS pair is connected to an APS test equipment, the test equipment does not see a match between the sent K1 channel and the received K2 channel

Workaround: None. Upgrade to ME27/MEF or newer versions of firmware

CSCdp45555

Symptom: APS: signal degrade and signal fail threshold does not work

Condition: Configuring of SD and SD thresholds do not work on BXM-E cards

Workaround: Use defaults.

CSCdp52921

Symptom: BPX node sometimes sees signal degrade when run switchyred

Condition: Performing switchyred cause the line to stay stuck in SD condition

Workaround: Perform switchyred again

The following bugs are fixed between MED & MEE

Bugs Fixed in MED

The following bugs are fixed in MED

Bug ID  Description 

CSCdm53420

Symptom: switchyred causes APS line to switch when last user request is clear

Condition: APS 1+1 configuration. The protection line was active and the "last user switch request" was clear. When a switchyred was performed, APS line switched to working line active

Workaround:

CSCdm93274

Symptom: OC3 back card LED is wrong after reset/pull cards

Condition: Multiple APS lines on a card and perform switchyred when Working line is active and Secondary card is active

Workaround: None.

CSCdm04312

Symptom: The problem is a false failure is declared against the SIMBA Multicast Record RAM.

Condition: The problem occurs when Self Test is activated against a Y-Redundant pair of BME Cards (BXM-622 cards loaded with the multicast BME firmware) that have more than 1000 connections programmed through them.

Workaround: Disable Self Test via the cnftstparm command.

CSCdm50659

Symptom: Trunk alarms are not generated when random bit errors are injected onto a trunk using an Adtech Sx14 test set at a rate of 10E-3. There are trunk statistics generated but no trunk alarm because the statistics that cause alarms on do not meet the threshold for MAJOR or MINOR alarms.

CSCdm50659

Symptom: Trunk alarms are not generated when random bit errors are injected onto a trunk using an Adtech Sx14 test set at a rate of 10E-3. There are trunk statistics generated but no trunk alarm because the statistics that cause alarms on do not meet the threshold for MAJOR or MINOR alarms.

Condition: This was generated in a lab environment with test equipment that was set to inject bit errors randomly through the entire bandwidth. Some HCS errors were generated as well as Path unavailable and Path Farend unavailable.

Workaround: Lowering the alarm threshold for MAJOR and MINOR HCS errors can help to generate a trunk alarm. Use the cnflnalm command and modify the Hcserr alarm thresholds to.01 for MAJOR and.0001 for MINOR. These thresholds are as low as they can be set currently.

CSCdk42527

Symptom: Rx Queue becomes full after LOS on the feeder trunk

Condition: After LOS condition on the feeder trunk

Workaround: Reset the feeder trunk

CSCdm16505

Symptom: AIS not sent on VP ABRFST/ABRSTD connection

Condition: LOS on trunk between 2 nodes

Workaround: none

CSCdm81534

Symptom: ICR of abrfst on BXM-155 falls down to MCR after resetcd

Condition: Change the ICR after resetcd before start sending traffic

Workaround: None

CSCdm61493

Symptom: When BIP8 errors are received on an E3 line or trunk at a rate of 10E-3, the line or trunk will not declare any alarm.

Condition: When high rates of BIP8 errors are received.

Workaround: None.

CSCdk81384

Symptom: BXM slot errors keeps on incrementing on a BCC3 node, but the reading of'EAP ARFD' should only be interpreted when using the dual receiver feature on a BCC4 node.

Condition: BXM slot errors on a BCC3 node

Workaround: None

CSCdk80483

Symptom: TX cell loss counts in dsptrkerrs increase continuously.

Condition: When there is trunk configured.

Workaround: None.

CSCdm04312

Symptom: The problem is a false failure is declared against the SIMBA Multicast Record RAM.

Condition: The problem occurs when Self Test is activated against a Y-Redundant pair of BME Cards (BXM-622 cards loaded with the multicast BME firmware) that have more than 1000 connections programmed through them.

Workaround: Disable Self Test via the cnftstparm command.

CSCdm09295

Symptom: Reconfig of FCES from enable to disable does not work, as a result traffic burst is restricted to MCR.

Condition: Every time changing an existing connection from FCES enable to disable.

Workaround: delete the connection and add back a new one with FCES disable

CSCdm39186

Symptom: Card fatal error occurred when running in standby mode under the heat condition. As a result, the card reset periodically.

Condition: Card running in standby mode under heat condition

Workaround: none

CSCdm09882

Symptom: Log non fatal message related to the RCMP errors

Condition: It is mainly seen in the heat chamber

Workaround: Please make sure the TEST FREQUENCY and TIMEOUT variables under cnftstparm for BXM are set to 4000/3700 level.

CSCdm31923

Symptom: AIS/YEL alarm doesn't go away even after the alarm is clear from the other end

Condition: It happens on the E3 when the LOOP TIME parameter is set to YES in the trunk or line configuration

Workaround: none

CSCdm92916

Symptom: Operational commands (dncd, resetcd, remove) on standby card impact active APS line

When active line is PROT line and a switchover of cards occur, WORK line becomes active line on the newly active cards.

Conditions: APS 1+1 Annex B and PROT is active line. switchyred or resetcd on the active card causes line to switchover from PROT to WORK.

Workaround: none

CSCdm92931

Symptom: APS line switchover occurs upon card removal/insertion when lockout is set

Conditions: When Lockout is set, removing/inserting the card makes it happen.

CSCdm52585

Symptom: DspVsiPartInfo shows very large Available LCN field.

Condition: When the sum of min-lcns is greater than the max(max lcns) on a port group.

Workaround: none.

CSCdp18840

Symptom:The CBR.2 Calls do not pass traffic above 50 Cells/second.

Condition:VSI controller establishes CBR.2 connection and it does not fill in the PCR field.

Workaround:Fill the PCR value aslo with the CR value.

CSCdp17741

Symptom:2-portgroup card reports 1 port group at the channel stats level 2 and 3.

Condition:When channel stats level 2 or 3 are configured on BXm-622-2 port and BXM-155 reports only one port group.

Workaround: Auto Route connections are not affected by this. But for VSI connections there is no work around.

CSCdp22930

Symptoms: Intlock missing for rd/wr operation

Workaround:

Reassert intLock on commbus ISR to prevent SCC access from getting interrupted

CSCdp33894

Symptom: standby APS line shows status as Path AIS upon switchyred or on APS switchover on LOS

Conditions: switchyred on APS, the prot. line report Path AIS

Workaround: NONE. upgrade to ME26/MED or later versions of BXM firmware

CSCdp36324

Symptom: last user request affects switching on BPX.

Conditions:

Workaround:

CSCdp31325

Symptom: UBR cells are policed unnecessarily below PCR.

Conditions: Always.

Workaround: none.

CSCdp36155

Symptom: BXM-E OC3/OC12 does not show supporting APS HW 1+1 in dspcd command and otherwise also.

Condition: BXM-E OC3/ OC12 card with HW rev < 'C'

Workaround: None.

CSCdp32853

Symptom: The BXM enhanced cards keep getting reset and card errors are logged and node may go into degraded mode, when command "addapsln slot1.port1 slot2.port2 1" is issued.

Condition: BXM enhanced OC3 cards with 4 port and FW rel earlier that M.E.22/M.F.09

Workaround:

1.Do not addapsln on second port onwards for BXM-E OC3 4 port card.

OR

2. Replace the BXM-E 4 port card with 8 ports card.

CSCdp17741

Symptom:2-portgroup card reports 1 port group at the channel stats level 2 and 3.

Condition: When channel stats level 2 or 3 are configured on BXm-622-2 port and BXM-155 reports only one port group.

Workaround:Auto Route connections are not affected by this. But for VSI connections there is no work around.

CSCdp11025

Symptom: Use the "dspapsln" to get the screen to dsiplay apsln status.When the working line is taken out the LOS appears on the working line. when the protection line is taken out both the working and protection display LOS. When the protection line is put back in the LOS/Alarms on the protection should clear. They do not.

Conditions:

Physically remove and add the rx or both rx and tx lines as follows:

1- remove the working line.

2- remove the protection line.

3- Add the protection line back.

Workaround

None

CSCdm73220

Symptom: Trunks or Virtual Trunks does not allow traffic going through.

Condition: Switch Software 9.1 with ME level of firmware. Trunks or VTs configured on BXM/BXM-E.

Work around: None

Bugs Fixed in MEC

The following bugs are fixed in MEC

Bug ID  Description 

CSCdm66131

Symptom:

After addapsln trunk goes to LOS

Condition:

Both ends have secondary card active, add aps 1+1 to one end, then add aps to the other end, the trunk sometimes goes into LOS.

Workaround:

CSCdm64366

Symptom:

APS 1+1 manual switch sometimes does not work after a while after several manual switch and auto switch.

Condition: Secondary card is active and several manual switch and auto switches are performed.

Workaround:

CSCdm62809

Symptom:

APS 1+1 bidirectional non-revertive switches back to working line when line condition clears on working.

Condition:

APS 1+1 configured in bidirection non-revertive mode.

Working line is in LOS, current active line is protection, clear LOS on working line.

Workaround:

CSCdm69974

Symptom:

Card errors (0x25170076) occur when only one Virtual Trunk is configured in a physical port.

Workaround:

CSCdm65813

Symptom: APS switches back o working line incorrectly.

Condition: switch sequence W->P, P->W and then W->P, then cause LOS on WORK line and put the cable back, APS switches to Working line.

Workaround:

CSCdm77212

Symptom: When addshelf command is executed, it comes back with a communication breakdown.

Condition: channel level stats is set to 0 so that BXM reports wrong max channels.

Workaround:

CSCdm74316

Symptom: Re-adding VSI shelf does not work until a resetcd is executed on the LSC control port.

Condition: Load information on an interface is 4 bytes more that MAX_VSI_MSG,

So the message gets dropped on BXM, so VSI controller is in discovery state forever.

Workaround:

CSCdm75722

Symptom: No control VC after BXM is reset.

Condition: When resync request comes down from the VSI controller with 19 checksum blocks, the length check done on BXM does not include padding.

Workaround:

CSCdm74968

Symptom: 0B card error causing BXM to reset

Condition: Over night jobs running on controller cards.

Workaround:

CSCdp02190

Symptom: tstdelay timed out when going through BNI trunk

Condition: more that 12 VTs on an interface causes wrong port-vi mapping while considering STI_SHIFT/NO_SHIFT from 13 the VT/port onwards.

Workaround:

CSCdm78335

Symptom: dspvsistatus rarely shows the VSI programming status as Done

Condition: primary and secondary port has two different VPI range.

Workaround:

CSCdm26752

Symptom: Card errors continuously logged with "SoItcSend failed" message.

Condition: RAS oam_lpbk is on and switchyred is executed several times in a job.

Workaround:

CSCdm93839

Symptom: Card resets on receiving oam loopback cells at high rate

Condition: oamlpbk is enabled with high oam traffic on large number of connections.

Workaround:

CSCdm52254

Symptom: BIP-8 code errs occurs on routing trunks

Condition: T3 card used in HEC mode can randomly have this problem.

Workaround:

CSCdm44183

Symptom: BXM-155 4DX was not able to recover after resetting the card

Condition: Traffic is sent at a rate >= 383 cps on a terminated connection on BXM-E card and then card is reset.

Workaround:

CSCdm90997

Symptom: BXM-E trunk and port stats are always zero in TX direction.

Condition: port terminated on BXM-E card or trunk passing through BXM-E card.

Workaround:

CSCdm80991

Symptom: Unable to add 3 segment connections using CM GUI

Condition: feeder connected to BXM card of BPX routing node and for, BXM trunk invigoration, ILMI/LMI protocol is enabled as CARD based.

Workaround:

CSCdm82688

Symptom: traffic Shaping problems with VT with and without wraparound solution

Condition: large deviations in CDV values

Workaround:

CSCdm94372

(see explanation below)

Symptom: Trunks sometimes drop cbr traffic

Condition: If a trunk is configured to full line rate on BXM cards, then traffic is dropped

Workaround:

CSCdp00063

Symptom: Node unreachability is experienced on VTs (virtual trunks)

Condition: Multiple VTs are configured on a trunk interface of the BXM/BXM-E

Workaround: configure only one VT per trunk interface

Logic to calculate actual cell transmission rate in a BXM card is as follows (CSCdm94372):

if (configured cell rate == full line cell rate) then

transmitted cell rate = full line cell rate

else

transmitted cell rate = from equation below or from table 1


example:

if a trunk is configured at 100,000 CPS, the actual transmitted cell rate is then 98,013 CPS

any traffic sent over 98,013 CPS would be discarded.

Therefore, only rates in the table or computed from the equation should be used.

Otherwise cell loss may be experienced.

1464865

56552

28832

19348

14559

11670

9738

8355

733860

54458

28278

19097

14416

11579

9674

8308

489558

52513

27744

18852

14277

11488

9611

8261

367288

50703

27231

18614

14139

11399

9549

8215

293888

49013

26736

18381

14005

11311

9487

8169

244938

47432

26258

18154

13872

11225

9426

8124

209966

45950

25798

17933

13743

11140

9366

8079

183733

44558

25353

17717

13616

11056

9307

8035

163327

43247

24923

17506

13491

10974

9248

7992

147001

42012

24508

17300

13368

10892

9190

7948

133642

40845

24106

17099

13248

10812

9133

7906

122509

39741

23717

16902

13129

10733

9077

7863

113088

38695

23341

16710

13013

10656

9021

7822

105012

37703

22976

16522

12899

10579

8966

7780

98013

36761

22623

16339

12787

10503

8912

7739

91889

35864

22280

16159

12677

10429

8858

7699

86485

35010

21947

15983

12568

10355

8805

7659

81681

34196

21625

15812

12462

10283

8753

7619

77383

33419

21311

15643

12357

10212

8701

7580

73515

32676

21007

15479

12254

10141

8650

7541

70014

31966

20711

15318

12153

10072

8599

7502

66833

31286

20423

15160

12053

10003

8549

7464

63927

30634

20143

15005

11955

9936

8500

7427

61264

30009

19871

14853

11859

9869

8451

7389

58814

29409

19606

14705

11764

9803

8403

7352

Bugs Fixed in MEB

The following is the list of bugs fixed in release MEB.

Bug ID  Description 

CSCdm50469

Symptom:

Software error 105 and malloc card errors happened continuously

Condition:

When jobs that cause reroutes of connections (e.g. switchcc, hitless rebuild) are run for a long time, sometimes BXM card freezes with malloc card errors and software error 105.

Workaround:

None

CSCdm50723

Symptom:

After deleting APS, switchyred causes temporary LOS when the other end still has APS.

Condition:

One end has APS 1+1, other end was added with APS 1+1 and line is up between the two ends. Then APS is deleted from one end. The primary card is active on non APS end. On switchyred on the non APS end there is a temporary LOS. If APS was never added to one end, then switchyred does not result in temporary LOS.

Workaround:

Instead of deleting APS first and then doing a switchyred, do a switchyred first and then delete APS. This does not result in temporary LOS.

CSCdm63038

Symptom:

BXM card fails with breakpoint error.

Condition:

When tx cell rate of a trunk is reduced to zero, BXM card fails with break point error (division by zero).

Workaround:

None

Bugs Fixed in MEA

The following is the list of bugs fixed in release MEA:

Bug ID  Description 

CSCdm09882

Symptom:

Log non fatal message related to RCMP errors.

Condition:

It is mainly seen in the heat chamber.

Workaround:

None

CSCdm18186

Symptom:

AIS status could be randomly be displayed in dspcon

Condition:

When the connection AIS signal is constantly changing, the dspcon/dspchstats OAM status will not be accurate for all the connections on the card.

Workaround:

None

CSCdm26380

Symptom:

Software error 9098 occured during switchyred BXM

Condition:

This problem occurs on cards with the APS channels halved option set and then doing a cnfrsrc on a port that belongs to the second port group. Note that this fix will cause a card mismatch on active cards with channel halved option turned on.

Workaround:

None

CSCdm31923

Symptom:

AIS/YEL alarm doesn't go away even after the alarm is clear from the other end.

Condition:

It happens on the E3 when the LOOP TIME parameter is set to YES in the trunk or line configuration.

Workaround:

None

CSCdm37519

Symptom:

Trunks go to Communication Fail after burning firmware.

Condition:

When MC10 is burnt into BXM-OC12 with trunks.

Workaround:

None

CSCdm37709

Symptom:

APS line fails to clear channel mismatch after lockout.

Condition:

Bi-direction APS 1+1. Local end has locked out of protection set. Then WORK cable is pulled out on local end to cause LOS. Lockout is then cleared and then the WORK cable is put back. This causes a channel mismatch on the far end and the mismatch never clears.

Workaround:

None

CSCdm38647

Symptom: This bug has been fixed in MEA such that the firmware reports the correct number of port groups. The side effect of this fix is that the Switch Software could mismatch the BXM card. If there is a card mismatch then down all the lines/trunks on the card and up them again.

Condition: When the user loads the MEA firmware on the BXM card running MDA with APS halved channeled enabled, then the card will come up in mismatched state.

Workaround:

None

CSCdm46658

Symptom:

switchapsln command does not work for APS AnnexB line.

Condition:

Annex B configuration if hitless rebuild is done when active line is PROT, then switchapsln does not work after hitless rebuild.

Workaround:

None

Bugs Fixed in MDA

The following is the list of bugs fixed in release MDA:

Bug ID  Description 

CSCdm38647

Symptom:

MDA fw may report incorrect number of port-groups when APS channels are set to halved.

Condition:

When user attempts to add all the channels available on the card on one port-group, it may be allowed even though the BXM may not have enough memory to support it. Also, this may cause a mismatch state when MDB firmware is burnt.

Workaround:

Down all the line/trunks on the card and up them again.

CSCdm23713

Symptom:

VI numbers are not modified by firmware.

Condition:

When one or more trunks are failed in the network, there may be a combreak in the network.

Workaround:

Set all the Virtual trunks to restrict CC traffic.

CSCdm23827

Symptom:

APS alarm may clear on switchyred.

Condition:

After a switchyred, an existing a LOS/LOF alarm may get cleared. This will only happen when the line has switched to protection before the card switchover is performed.

Workaround:

None

CSCdm23752

Symptom:

BXM fw does not allow a networking channel on VTs to configured for egress only.

Condition:

BXM fw allowed configuration of networking channel to be bidirectional only.

Workaround:

None

Firmware Filenames and Sizes

Filename  Size 

BXMMEJ.000

65536

BXMMEJ.001

65536

BXMMEJ.002

65536

BXMMEJ.003

65536

BXMMEJ.004

65536

BXMMEJ.005

65536

BXMMEJ.006

65536

BXMMEJ.007

65536

BXMMEJ.008

65536

BXMMEJ.009

65536

BXMMEJ.010

65536

BXMMEJ.011

65536

BXMMEJ.012

65536

BXMMEJ.013

65536

BXMMEJ.014

65536

BXMMEJ.015

65536

BXMMEJ.016

65536

BXMMEJ.017

65536

BXMMEJ.018

65536

BXMMEJ.019

65536

BXMMEJ.020

65536

BXMMEJ.021

65536

BXMMEJ.022

13936

BXMMEJ.023

14

BXMMEJ.024

2

BXMMEJ.IMG

784

BXMMEJ.img

784

Appendix B

UXM ABL Firmware Release Notes

ABL is a new firmware release for the UXM card on IGX. Firmware is the same for UXM and UXM-E cards.

New Features

Flash memory drivers are upgraded to support more flash memory vendors so that more flash manufacturers can be used to source components.

Obsolete Features

None.

Compatibility

Software

ABL firmware is compatible with Switch Software 9.1 and 9.2

Hardware

ABL is compatible with UXM and UXM-E model H/W all models.

Previous Versions of UXM Firmware

On IMA trunks this version is not compatible with UXMs Model B firmware versions ABA to ABD.

On IMA trunks Model B firmware (AB*) is not compatible with model A (AA*) because model B is Standards compliant and model A is not. So IMA trunks must be upgraded together.

Bugs Fixed in this Release

Bug ID  Description 

CSCds08193

Symptom:

Although the trunk operates fine, the dspportstats will show the old delay value even though the actual delay on the line is different. IMA trunk statistics will not show the correct delay value when the delay is toggled rapidly.

Condition:

Whenever the delay is changed rapidly on one of the links in an IMA group the dspportstats on that trunk is not updated. The errors seen are related to the SX/12 tester operation. No errors are seen when the SX/13 is used.

Workaround:

Change the delay with gaps of approximately a minute between changes.

Upgrade Instructions

Upgrade boot code to boot 07 before upgrading to ABL.

Notes and Cautions

This firmware enables flash components from multiple new vendor to be used. Previous versions of firmware cannot write on to these new devices. For new cards with the flash devices from new vendors, firmware cannot be downgraded to versions prior to ABL. If this is attempted, burnfwrev will fail leaving firmware revision ABL in the flash.

Boot Code Requirements

Boot Code revision boot_07 is needed for the ABL release.

Obtaining Service and Support

For service and support for a product purchased from a reseller, contact the reseller. Resellers offer a wide variety of Cisco service and support programs, which are described in the section "Service and Support" in the information packet that shipped with your chassis.


Note   If you purchased your product from a reseller, you can access Cisco Connection Online (CCO) as a guest. CCO is Cisco Systems' primary, real-time support channel. Your reseller offers programs that include direct access to CCO's services.

For service and support for a product purchased directly from Cisco, use CCO.

Cisco Connection Online

Cisco Connection Online (CCO) is Cisco Systems' primary, real-time support channel. Maintenance customers and partners can self-register on CCO to obtain additional information and services.

Available 24 hours a day, 7 days a week, CCO provides a wealth of standard and value-added services to Cisco's customers and business partners. CCO services include product information, product documentation, software updates, release notes, technical tips, the Bug Navigator, configuration notes, brochures, descriptions of service offerings, and download access to public and authorized files.

CCO serves a wide variety of users through two interfaces that are updated and enhanced simultaneously: a character-based version and a multimedia version that resides on the World Wide Web (WWW). The character-based CCO supports Zmodem, Kermit, Xmodem, FTP, and Internet e-mail, and it is excellent for quick access to information over lower bandwidths. The WWW version of CCO provides richly formatted documents with photographs, figures, graphics, and video, as well as hyperlinks to related information.

You can access CCO in the following ways:

For a copy of CCO's Frequently Asked Questions (FAQ), contact cco-help@cisco.com. For additional information, contact cco-team@cisco.com.


Note   If you are a network administrator and need personal technical assistance with a Cisco product that is under warranty or covered by a maintenance contract, contact Cisco's Technical Assistance Center (TAC) at 800 553-2447, 408 526-7209, or tac@cisco.com. To obtain general information about Cisco Systems, Cisco products, or upgrades, contact 800 553-6387, 408 526-7208, or cs-rep@cisco.com.




hometocprevnextglossaryfeedbacksearchhelp
Posted: Tue Jul 15 01:31:41 PDT 2003
All contents are Copyright © 1992--2003 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.