cc/td/doc/product/wanbu/bpx8600/9_1
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Configuration, Initial Setup

Configuration, Initial Setup

This chapter contains configuration procedures.

This chapter contains the following:



The BPX switch can be accessed through a local control port (over an RS-232 or Ethernet TCP/IP link.) An administration screen from a control terminal or from the Cisco StrataView Plus Network Management Station (NMS) can issue BPX switch commands. Remote control terminal access is possible using a Virtual Terminal (vt) command if the node has been configured with a name and at least one trunk to the network has been established.

For frame relay connections in both tiered and non-tiered networks Cisco StrataView Plus provides end-to-end configuration management using the Connection Manager. When an IPX or IGX is configured as an Interface Shelf, it can not be reached by the vt command, and frame relay end-to-end connections are configured from StrataView Plus via the Connection Manager over an in-band LAN connection. (Telnet can be used to access an interface shelf (e.g., IPX or IGX shelf or MGX 8220 shelf) if a Cisco StrataView Plus workstation is not available to provide in-band management.)

BPX Switch Management

You can monitor, manage and troubleshoot the BPX switch using the Cisco StrataView Plus Network Management Station. Commands are issued to a BPX switch through the Node Administration window. Frame Relay connections are added via the StrataView Plus Connection Manager. You can display and monitor the network's topology, monitor alarms, events, and statistics. Refer to the Cisco StrataView Plus Operations Guide for more information.

For detailed configuration information, refer to the Cisco WAN Switching Command Reference publication.

Initial Node Configuration Summary

Adding Nodes, Adding Trunks, Shelves, etc.

Refer to the applicable reference publications, Cisco IPX Reference, Cisco BPX 8600 Series Reference, Cisco IGX 8400 Series Reference, and Cisco MGX 8220 Reference, for node installation and operation.

As a minimum, the nodes need to be configured with name (cnfname), date (cnfdate), time (cnftime), timezone (cnftmzn), and trunks upped (uptrk) and added (addtrk or addshelf), as applicable. Connections can also be added now or later, after configuring the nodes for operation with the Cisco StrataView Plus NMS manager.

The basic tasks to configure a BPX switch are as follows:

The following two examples are of the screens displayed when "dspnode" is entered at a BPX switch and at one of its IPX shelves, respectively. The "dspnode" screen displayed at the "hubone' BPX switch shows that it is connected to the "shlf3ipx" node via BNI trunk 3.3. The "dspnode" screen displayed at the "shlf3ipx" node show that it is connected to the BPX switch via AIT trunk 8.

Example of dspnode at node "hubone" BPX15 showing feeder shelves

hubone TN edgar BPX 15 9.1 Nov. 20 1997 08:09 PST BPX Interface Shelf Information Trunk Name Type Alarm 1.2 shlf1 MGX 8220 OK 1.3 shlf2 MGX 8220 OK 3.1 shlf1IPX IPX/AF OK 3.2 shlf2IPX IPX/AF OK 3.3 shlf3IPX IPX/AF OK 4.1 shlf4IPX IPX/AF OK 4.3 shlf5IPX IPX/AF OK Last Command: dspnode

Example of dspnode at node Shlf3IPX showing connection to "hubone"

shlf3IPX TN edgar IPX 8 9.1 Nov. 20 1997 09:24 PDT BPX Switching Shelf Information Trunk Name Type Alarm 8 hubone BPX MAJ Last Command: dspnode Next Command:

IP Setup and IP Relay Configuration

In setting up network management for a network, both the Cisco StrataView Plus workstation and network nodes need to be configured. Cisco StrataView Plus communicates over a standard physical LAN network to a gateway node or nodes, but a separate in-band IP relay network is setup for all nodes via a gateway node for SNMP and TFTP in-band communication over the node trunks.

On IPX, BPX, IGX switches, the following commands are used to configure the nodes for operation with Cisco StrataView Plus: cnflan, cnfnwip, cnfstatmast, cnfsnmp. The MGX 8220 is configured with cnfifip and cnfstatsmgr. The cnflan command is only necessary for nodes or shelves in which the LAN port is actually connected to a physical Ethernet LAN as shown in Figure 10-1.


Figure 10-1: Cisco StrataView Plus Physical LAN and IP Relay Network

Installing Cisco StrataView Plus and Associated Applications

Refer to the Cisco StrataView Plus Operations Guide, Cisco StrataView Plus Installation Guide, Cisco WAN Switching Command Reference, and Cisco MGX 8220 Reference publications for additional information.

Configuring the Cisco StrataView Plus Workstation (example)


Step 1   Contact your System Administrator to obtain IP addresses. Also, for the workstation to use /etc/hosts, it must not be able to access the NIS directory even though it may be linked to other LANs besides its own local network.

Step 2   Enter physical IP addresses and physical LAN node names (with a letter "p", for example, such as "nw1bpx1p", to differentiate from IP relay name) in /etc/hosts and also enter IP relay addresses with actual configured node names ("nw1bpx1", for example).

beacon% more /etc/hosts # # Sun Host Database # # If the NIS is running, this file is only consulted when booting # 127.0.0.1 localhost # 204.179.61.121 beacon loghost # node physical ethernet LAN addresses 204.179.61.104 nw1bpx1p 204.179.61.71 nw1axi1p # node ip relay addresses 204.179.55.101 nw1ipx1 204.179.55.102 nw1ipx2 204.179.55.103 nw1ipx3 204.179.55.123 nw1igx1 204.179.55.111 nw1bpx1 204.179.55.105 nw1axi1
  If the workstation is connected to the corporate network for access to hosts on another network, add any IP addresses and associated names of the hosts that you may want to connect to your workstation, as the NIS is disabled.

Step 3   Enter the name or IP address of the gateway node in config.sv, using physical LAN name e.g., "nw1bpx1p". Note; normally a BPX switch is used for the gateway node because of its greater processing power.

0|Network1|nw1bpx1p|9600|0|7|6|0|30|1024|9.1|

or

0|Network1|204.179.61.104|9600|0|7|6|0|30|1024|9.1|

Step 4   Enter IP Relay subnet mask in /etc/rc2.d/S72inetsvc file as follows:

vi /etc/rc2.d/S72inetsvc /usr/sbin/route add "224.0.0.0 ...................{this is already there # route add for Cisco StrataView Plus route add net 204.179.55.0 204.179.61.104 1
Note The route add command sets up the route for all nodes in the 204.179.55.0 IP relay subnetwork. In this example, the name "nw1bpx1p" is the name in the /etc/hosts table associated with the physical LAN port IP of 204.179.61.104 on the gateway node, e.g., "nw1bpx1". In steps 2 and 3, either the name "nw1bpx1p" or the IP of "204.179.61.104" can be entered.

Configuring the LAN Port


Note Configure the LAN parameters of the nodes before connecting them to a LAN.

Note Refer to the StrataView Plus Operations document and the Commands Reference for additional information.

Step 1   Contact your System Administrator to obtain IP addresses for your workstation and for the BPX/IGX/IPX switches you are going to configure. Also, access to the NIS directories should be disabled so that the workstation will consult the /etc/hosts table for IP LAN and IPX relay addresses.

Step 2   Normally, the System Administrator will provide the IP addresses for the workstation and node. Refer to the Cisco StrataView Plus Operations manual for instructions on configuring the Cisco StrataView Plus workstation.

The addresses shown are just examples. Use the addresses obtained from your System Administrator. (This example is for a workstation named "hedgehog" at address 192.187.207.200. It also assumes that the BPX, IGX, or IPX switch LAN port for node sanfran has been assigned an IP address of 192.187.210.30 and a hostname of sanfran. Your own host name and addresses will be different.)

192.187.207.200  hedgehog

192.187.210.30  sanfran


Note If an NIS is being used (e.g., corporate network), you will need to contact the System Administrator.

Note 5120 is used for the LAN ports on all BPX/IPX switch ports.

Step 3   Configure the LAN port on the BPX/IPX switch using a dumb terminal or an RS-232 connection via the workstation (using the vt command, as applicable) to enter the appropriate cnflan parameters.

The cnflan command configures the node's communication parameters so that the node can communicate with a StrataView Plus terminal over an Ethernet LAN using the TCP/IP protocol. The parameters contain address information about the Ethernet TCP/IP network that is used to connect the StrataView Plus station to an IPX or BPX switch. The values used must conform to those of the network and should be supplied by the Ethernet network administrator.

The cnflan command has the following parameters:

A cnflan screen is shown in the following example for the LAN setup shown in Figure 10-2. An IP address of 192.187.210.30 has been entered as the active IP address for the node. The IP Subnet mask is entered as 255.255.255.0 for a Class C LAN network. The TCP service port is entered as 5120. Since the workstation and node are on different networks in this example, a gateway address of 192.187.207.1 (the address of the node serving as a gateway for Cisco StrataView Plus, in this example), which must be obtained from your System Administrator, has been entered. If the workstation and node are both on the same network, no gateway address is needed. The "Maximum LAN Transmit Unit" and "Ethernet Address" parameters are not configurable by the cnflan command. The "Ethernet Address" is a hardware address that is different for every node controller card, e.g., BCC.

Example: Configuring a Control Port (Gateway Router Example)

beta TN YourID.1 BPX 15 9.1 Dec. 3 1997 02:16 PST Active IP Address: 192.187.210.30 IP Subnet Mask: 255.255.255.0 IP Service Port: 5120 Default Gateway IP Address: 192.187.207.1 Maximum LAN Transmit Unit: 1500 Ethernet Address: 00.C0.43.00.00.20 Type State TCP UNAVAIL UDP READY Telnet READY This Command: cnflan Enter IP Address:

Step 4   Connect the Cisco StrataView Plus workstation and the BPX switch to a LAN network. The LAN port on the BPX switch provides a DB-15 connector that can be connected to a Y-cable which in turn is connected to an AUI.

Step 5   To test that a LAN connection to the BPX switch LAN port is okay, for example, for a hostname of "sanfran" entered in the config.sv file, you could enter the following at the Cisco StrataView Plus workstation:

ping sanfran
Figure 10-2: Cisco StrataView Plus LAN Connection via Gateway Router to a BPX Switch


Step 6   An IP Relay address needs to be configured for each node. The following example shows an example of using the cnfnwip command to configure the IP Relay address for a node. Also, at the workstation, the /etc/hosts table and routing need to be set up for each node in the network. This is so that network management using SNMP and statistics collection using TFTP via inband ILMI may be carried out. Also, assuming an isolated network for the nodes, the workstation must be isolated from the NIS reference pages in order that the Cisco StrataView Plus workstation consults the /etc/hosts table. Refer to the Cisco StrataView Plus Installation and Operation manuals for further information.

Example Display using cnfnwip to configure IP Relay address (required for each node):

beta TN YourID BPX 15 9.1 Dec. 3 1997 02:11 PST Active Network IP Address: 192.187.57.10 Active Network IP Subnet Mask: 255.255.255.192 Last Command: cnfnwip Next Command:

Step 7   Once the workstation and BPX switch interface have been set up, Cisco StrataView Plus can be started. The following example shows the dsplan screen after Cisco StrataView Plus has been started and the communication sockets are active.


Note "Sockets" is the BSD Unix name for connections between processes, typically used in network communication.

Example of dsplan after Cisco StrataView Plus has been started:

beta TN YourID.1 BPX 15 9.1 Dec. 3 1997 02:16 PST Active IP Address: 192.187.210.30 IP Subnet Mask: 255.255.255.0 IP Service Port: 5120 Default Gateway IP Address: 192.187.207.1 Maximum LAN Transmit Unit: 1500 Ethernet Address: 00.C0.43.00.00.20 Control Socket - Ready Open Socket Descriptor - 2 Last Command: dsplan Next Command:

Figure 10-3 shows an example of a Cisco StrataView Plus workstation LAN connection to a BPX switch on a network with no gateway router, nor connection to another LAN. This type of LAN connection could also be connected through a "Hub" which is essentially a signal splitter (passive or active).


Figure 10-3: Cisco StrataView Plus LAN Connection to an IPX Node (no gateway)


Configuring the MGX 8220 for Cisco StrataView Plus NMS Operation (example)


Note The MGX 8220 was formerly sometimes referred to as the AXIS shelf.

At installation, initial access to the MGX 8220 is provided by the control port. The following is a brief overview of initial configuration. Refer to the Cisco MGX 8220 Reference manual for detailed information. Also refer to appropriate release notes for applicable firmware and software versions.


Step 1   Connect a terminal to the service port on the MGX 8220.

Step 2   Login.

login: "LoginID" password: card number: 3 xxxxAXIS.1.3.ASC.a >

Step 3   Name the shelf.

xxxxAXIS.1.3.ASC.a > cnfname nw1axi1

Step 4   Set the date.

nw1nw1axi1.1.3.ASC.a > cnfdate 05/02/96

Step 5   Set the time.

nw1saxi1.1.3.ASC.a > cnftime 15:31:00

Step 6   Enter Help for a list of commands.

nw1saxi1.1.3.ASC.a > Help

Step 7   Check versions of ASC, and Service Module (e.g., FRSM, AUSM) Firmware.

nw1axi1.1.3.ASC.a > version ***** AXIS ASC Card *****2 Firmware Version = 2.1.12b_______ Backup Boot version = model-B BT_2.0.0_______ ASCFRSM Xilinx file = asc025.h ASCBNM Xilinx file = bnmt3andsrefix VxWorks version 5.1.1-R3000. Kernel: WIND version 2.4. Made on Thu May 2 16:42:36 PDT 1996. Boot line: sl(0,0) cc

Step 8   Enter Ethernet LAN port IP address.

nw1axi1.1.3.ASC.a > cnfifip cnfifip "-ip <ip addr> -if <Interface> -msk <NetMask> -bc <Brocast addr> " -ip <IP addr> where IP addr = nnn.nnn.nnn.nnn -if <Interface> where Interface = 26,28,37, 26: Ethernet, 28: Slip 37: ATM -msk <NetMask> where NetMask = nnn.nnn.nnn.nnn -bc <BrocastAddr> where BrocastAddr = nnnnnnnn, n is hexdecimal, ethernet only nw1axi1.1.3.ASC.a > cnfifip -ip 204.179.61.71 -if 26
   You are configuring ethernet port are you sure? enter yes/no: yes

Step 9   Enter IP Relay Address for SNMP Management and Stats Collection.

nw1axi1.1.3.ASC.a > cnfifip -ip 204.179.55.105 -if 37
   You are configuring atm port are you sure? enter yes/no: yes

Step 10   Configure stat master address (IP of Cisco StrataView Plus workstation).

cnfstatsmgr "<ip address>" nw1axi1.1.3.ASC.a > cnfstatsmgr 204.179.61.121 {this is IP address of Cisco StrataView Plus workstn}

Adding Virtual Trunks

This section details the steps for setting up a virtual trunk. Virtual trunking is an optional feature that must be enabled by Cisco prior to adding virtual trunks. Also, revision levels of ASI and BNI firmware must be current. The following procedure assumes that Cisco equipment is used in the ATM Cloud as well as in the Cisco WAN Switching subnetworks. In this case, a BNI output from the subnetwork is connected to an ASI UNI input at the ATM Cloud (Figure 10-4). Proceed as follows:


Step 1   In the ATM cloud network, physically connect an ASI port at the cloud edge to each BNI port in the Cisco WAN Switching Network that is intended to have virtual trunks.


Figure 10-4:
Virtual Trunks across a Cisco Wan Switching ATM Cloud

Step 2   Configure the cloud ASI ports. For each ASI port connected to a BNI virtual trunk port, do the following:

upln <slot.port>

upport <slot.port>

cnfport <slot.port> and set the shift parameter to "N" for no shift if the cloud contains BPX switches.

Step 3   Execute addcon. In the cloud network, add a virtual path ASI connection for each virtual trunk that is to route through the cloud. An example of this syntax is:

addcon joker 5.1.1.* swstorm 6.2.10.*

Where 5.1 and 6.2 are ASI ports hooked up and configured for virtual trunking. Daxcons are acceptable.

Note that the third number is the VPI which must correspond to the virtual trunk VPI configured with cnftrk in step 4.

When the cloud is a public ATM service and not a Cisco WAN Switching cloud, the VPI is provided by the carrier, as well as the guaranteed BW associated with the VPI.

The CBR/VBR/ABR parameters must also correspond to the Virtual Trunk Type of the virtual trunk. For T3, set PCR to the bandwidth of the virtual trunk, and CDVT to 24000 for the connection so that the ASI does not drop cells. These are values that Cisco recommends based on testing.

Step 4   Configure BNI virtual trunks. On the BNIs that connect to the cloud ASI ports, configure up to 32 virtual trunks, as follows:

uptrk <slot.port.vtrk>

cnftrk <slot.port.vtrk>

For cnftrk, make sure that the virtual trunk type and the VPI correspond to the ASI Virtual Path connections that have been set up.

addtrk <slot.port.vtrk>


hometocprevnextglossaryfeedbacksearchhelp
Posted: Mon Jan 15 19:50:16 PST 2001
All contents are Copyright © 1992--2001 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.