VCs per AXIS Shelf | 2028 |
VCs per IPX Shelf (NPC 16M processor card) | 1024 |
LCons per IPX Shelf (NPC 16Mprocessor card) | 850 |
Connections per IPX Shelf (NPC 16M processor card) | 850 |
VCs per IPX Shelf (NPC 32 M processor card) | 1024 |
LCons per IPX Shelf (NPC 32M processor card) | 1000 |
Connections per IPX Shelf (NPC 32M processor card) | 1000 |
VCs per IPX Routing Node | 1024 |
VCs per IGX Routing Node | 1024 |
Connections per IPX Routing Node | 1024 |
Connections per IGX Routing Node | 1024 |
Interface Shelf trunks per Routing Hub | 16 |
Networking Trunks per Routing Hub | 32 |
(up to 16 of these can be used for Interface Shelf Trunks) |
|
VCs per Routing Hub (BCC 32M processor card) | 5000 grouped |
LCons per Routing Hub (BCC 32M processor card) | 1000 |
Connections per Routing Hub (BCC 32M processor card) | 5000 grouped connections |
Routing Nodes in a flat network (NPC 16M) | 63 |
Routing Nodes in a flat network (NPC 32M, BCC 32M) | 100 |
Routing Nodes in a domain (BCC 32M, NPC 32) | 63 |
*All IPX nodes must be equipped with NPCs. |
---|
Trunk Interfaces: | T3 and E3 |
Trunk Protocol: | Asynchronous Transfer Mode (ATM) |
Trunks per Node: | 32 DS3 or E3 trunks per BPX of which 16 can be shelf trunks 1 active DS3 or E3 trunk per IPX |
Trunk Bandwidth: | 96,000 cells/sec. (T3) 80,000 cells/sec. (E3) 353,208 cells/sec (OC3) |
Trunk Capacity: | 1221 inter-domain virtual circuits per BNI trunk. |
North American: | T1 Fractional T1 (minimum of 4 DS0s) T2 |
International: | CEPT E1 Subrate, 64 Kbps to 1.920 Mbps Japanese "Y1" |
Trunk Bandwidth: | 1.536 Mbps, 8,000 FastPackets/sec. (T1) 1.984 Mbps, 10,333 FastPackets/sec. (framed E1) 2.048 Mbps, 10,666 FastPackets/sec. (unframed E1) Subrate and fractional T1 depend on data rate selected |
Frame Relay: | Channelized T1: 56 Kbps, N x 64 Kbps, up to 1.536 Mbps. Channelized E1: G.703, N x 64 Kbps, up to 1.984 Mbps. V.35: configurable from 56 Kbps to 2.048 Mbps |
Data: | V.35: 56 Kbps to 1.344 Mbps. RS-449: 56 Kbps to 1.344 Mbps. |
Voice: | Channelized T1 Channelized E1 Channelized Japanese "TTC" DC5A and E&M channel associated signaling FAX/high-speed modem |
Line Rate: | 44.736 Mbps ±20 ppm, asynchronous. |
Line Code: | B3ZS. |
Signal Level: | DSX-3. |
Framing Format: | C-bit parity is monitored. No other framing or control bits in the DS3 frame are either altered or monitored. |
Protocol: | Physical Layer Convergence Protocol per AT&T Publication TA-TSY-000772 and 000773. |
ATM Cell Rate: | 96,000 cells/sec. Limited to 80,000 cells/sec. when interfacing with StrataCom IPX. |
Alarms Sent: | AIS. |
Alarms Received: | AIS. |
Line Errors Counted: | BPV. |
Jitter: | Meets ACCUNET T45 specification (Pub 54014). |
Connector: | 75 ohm BNC. |
Recommended Cable Lengths: | 900 feet (275 m.) max. using specified cable. |
Indicators: | Card status.Port status. |
Line Rate: | 34.368 Mbps ± 20 ppm, asynchronous. |
Line Code: | HDB3. |
Signal Level: | CCITT G.703. |
Framing Format: | CCITT G.804, G.832. |
Port Interface: | 75 ohm unbalanced. |
Barrier: | Fully barriered per EN 41003. |
ATM Cell Rate: | 80,000 cells/sec. |
Jitter: | per CCITT G.823 |
ATM Layer Protocol: | per CCITT I.361 with HEC. |
Port Alarm Processing: | AIS. |
Line Errors Counted: | BPV. |
Connector: | 75 ohm BNC. |
Max. E3 Cable Lengths: | 900 feet (275 m.) using specified cable. |
Indicators: | Card status. |
Line Rate: | 155.52 Mbps |
|
Line Code: | NRZ |
|
Signal Level: | Max | Min |
MMF TX | -8 dBm | -15 dBm |
MMF RX | -8 dBm | -28 dBm |
SMF LR TX | 0 dBm | -5 dBM |
SMF LR RX | -10 dBm | -34 dBm |
Framing Format: | STS-3c, STM1 |
|
Port Interface: | LMI, ILMI |
|
ATM Cell Rate: | 353,208 cells/sec. |
|
Jitter: | < 0.01 UI p-p, < 0.1 UI rms |
|
ATM Layer Protocol: | LMI, ILMI |
|
Port Alarm Processing: | LOS, LOF, LOP, Path AIS, Path Yellow | |
Line Errors Counted: | Section BIP8, Line BIP24, Line FEBE, Path BIP8, Path FEBE | |
Connector: | MMF SC SMF FC/PC |
|
Max. Cable Lengths: | MMF ~ 2 KM SMF IR ~20 KM SMF LR ~40 KM |
|
Indicators: | Card status. Port status. |
|
Capacity | 2 ports per card. |
Interface: | T3 |
Line Rate: | 96,000 cells/sec. |
No. of channels per card: | 1000 |
No. of channels per node: | 1000 or 5000 (grouped) |
VPI Addressing Range: | 0-255 (UNI), 0-1023 (NNI_7 |
VCI Addressing Range: | 1-4095 |
Queues: | 32, 16 per line (port) includes CBR, VBR, and ABR queues. |
Capacity | 2 ports per card. |
Interface: | E3 |
Line Rate: | 80,000 cells/sec. |
No. of channels per card: | 1000 |
No. of channels per node: | 1000 or 5000 (grouped) |
VPI Addressing Range: | 0-255 (UNI), 0-1023 (NNI_ |
VCI Addressing Range: | 1-4095 |
Queues: | 32, 16 per line (port) includes CBR, VBR, and ABR queues. |
Capacity | 2 ports per card. |
Interface: | OC3 |
Line Rate: | 353,208 cells/sec. |
No. of channels per card: | 1000 |
No. of channels per node: | 1000 or 5000 (grouped |
VPI Addressing Range: | 0-255 (UNI), 0-1023 (NNI_ |
VCI Addressing Range: | 1-4095 |
Queues: | 24, 12 per line (port) includes CBR and VBR queues. |
Number of Nodes: | 48 max. (with NPC with 16 M) 63 max. (with NPC or BCC) |
Network Capacity: | 1008 trunks max. |
Node Capacity: | 16 FastPacket trunks/node (IPX) 32 ATM trunks/node (BPX) of which 16 can be shelf trunks |
Connections per node: | 1024 max, or for the BPX, 5000 grouped. |
Hops per connection | 10 max. |
Frame relay ports per node: | 127 |
Network Size, max. | 384 nodes (junction nodes with PCC controllers) 504 nodes (junction nodes with NPC or BCC controllers) 8192 inter-domain virtual circuits max. |
Domains per network | 8 max. |
Nodes per domain | 48 max. with PCC in junction nodes 63 max. with NPC and/or BCC in junction nodes |
Junction nodes per network | 8 max. (with PCC controllers). 32 max. (with NPC or BCC controllers). |
Junction nodes per domain | 1 minimum, 2 recommended. |
Connections per node junction node local node |
512 inter-domain plus 500 intra-domain 1000 intra-domain |
Connections per inter-domain trunk | 213 (NTC) 1221 (ATM) |
Connections per intra-domain trunk local trunk intra-domain jct. trunk | Bandwidth limited only 63 |
Hops per connection | 10 near end local 3 inter-domain 10 far end local max. |
Network Clock | One clock source per domain must be defined. Network clock cannot propagate across domain boundary. |
Node Clock | 44.736 MHz, ±50 Hz (Stratum 3 per AT&T Pub 62411). Internal 8 KHz and 192 KHz clocks for synchronizing network interfaces. |
Clock Sources: | Internal, free-running oscillator. Phase-locked to any appropriate network interface. External input at T1 or E1 rate. |
Clock Output: | Single clock output at T1 or E1 rate for synchronizing co-located IPX node(s) or CPE. |
Clocking Hierarchy: | Network-wide or domain-wide (for structured networks) clock selection. |
NMS Terminal: | SUN Microsystems and StrataCom Rel. 8.2 StrataView Plus, Informix, Wingz, Motif, and HP OpenView software required for network management, Frame Relay connection provisioning, graphical display of network status, statistics gathering and display, and automatic downloading of software. |
Control Terminal: | DEC VT100 or equivalent terminal for basic system configuring and alarm monitoring. |
Remote Alarm Reporting: | Autodial modem may be connected to one of two control ports on each node for automatic reporting of network alarms. |
Remote Diagnostics: | Autoanswer modem may be connected to one of two control ports on each node for remote diagnostic access by StrataCom ISC or other authorized personnel. |
Network Control Ports: | Three ports per node, two with RS 232C interface, one with Ethernet LAN interface. (Nodes with PCC controller have only the two RS-232 ports). |
Alarm Notification: | Status of all trunks and nodes in network distributed to and stored by each individual node. Reported to StrataView Plus terminal at connecting node. |
External Alarms: | Meets Bellcore Compatibility Bulletin #143 and AT&T Technical Reference PUB 43801 DS1 (T1) facility alarm requirements. |
Structured Network Management | Centralized or de-centralized NMS supported |