cc/td/doc/product/wanbu/bpx8600/8_2_0
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Network Specifications

Network Specifications

VCs per AXIS Shelf

2028

VCs per IPX Shelf (NPC 16M processor card)

1024

LCons per IPX Shelf (NPC 16Mprocessor card)

850

Connections per IPX Shelf (NPC 16M processor card)

850

VCs per IPX Shelf (NPC 32 M processor card)

1024

LCons per IPX Shelf (NPC 32M processor card)

1000

Connections per IPX Shelf (NPC 32M processor card)

1000

VCs per IPX Routing Node

1024

VCs per IGX Routing Node

1024

Connections per IPX Routing Node

1024

Connections per IGX Routing Node

1024

Interface Shelf trunks per Routing Hub

16

Networking Trunks per Routing Hub

32

(up to 16 of these can be used for Interface Shelf Trunks)

VCs per Routing Hub (BCC 32M processor card)

5000 grouped

LCons per Routing Hub (BCC 32M processor card)

1000

Connections per Routing Hub (BCC 32M processor card)

5000 grouped connections

Routing Nodes in a flat network (NPC 16M)

63

Routing Nodes in a flat network (NPC 32M, BCC 32M)

100

Routing Nodes in a domain (BCC 32M, NPC 32)

63

*All IPX nodes must be equipped with NPCs.

Broadband Trunk Interfaces

Trunk Interfaces:

T3 and E3

Trunk Protocol:

Asynchronous Transfer Mode (ATM)

Trunks per Node:

32 DS3 or E3 trunks per BPX of which 16 can be shelf trunks

1 active DS3 or E3 trunk per IPX

Trunk Bandwidth:

96,000 cells/sec. (T3)

80,000 cells/sec. (E3)

353,208 cells/sec (OC3)

Trunk Capacity:

1221 inter-domain virtual circuits per BNI trunk.

Narrowband Trunk Interfaces

North American:

T1

Fractional T1 (minimum of 4 DS0s)

T2

International:

CEPT E1

Subrate, 64 Kbps to 1.920 Mbps

Japanese "Y1"

Trunk Bandwidth:

1.536 Mbps, 8,000 FastPackets/sec. (T1)

1.984 Mbps, 10,333 FastPackets/sec. (framed E1)

2.048 Mbps, 10,666 FastPackets/sec. (unframed E1)

Subrate and fractional T1 depend on data rate selected

Narrowband Channel Interfaces

Frame Relay:

Channelized T1: 56 Kbps, N x 64 Kbps, up to 1.536 Mbps.

Channelized E1: G.703, N x 64 Kbps, up to 1.984 Mbps. V.35: configurable from 56 Kbps to 2.048 Mbps

Data:

V.35: 56 Kbps to 1.344 Mbps.

RS-449: 56 Kbps to 1.344 Mbps.

Voice:

Channelized T1

Channelized E1

Channelized Japanese

"TTC" DC5A and E&M channel associated signaling

FAX/high-speed modem

ATM T3 Trunk Interface (BNI-T3, LM-3T3)

Line Rate:

44.736 Mbps ±20 ppm, asynchronous.

Line Code:

B3ZS.

Signal Level:

DSX-3.

Framing Format:

C-bit parity is monitored. No other framing or control bits in the DS3 frame are either altered or monitored.

Protocol:

Physical Layer Convergence Protocol per AT&T Publication TA-TSY-000772 and 000773.

ATM Cell Rate:

96,000 cells/sec. Limited to 80,000 cells/sec. when interfacing with StrataCom IPX.

Alarms Sent:

AIS.
Remote

Alarms Received:

AIS.
Loss of Signal.
Remote.
Loss of Framing.

Line Errors Counted:

BPV.
Parity Bit Errors.

Jitter:

Meets ACCUNET T45 specification (Pub 54014).

Connector:

75 ohm BNC.

Recommended Cable Lengths:

900 feet (275 m.) max. using specified cable.
450 feet (150 m.) to a DS3 crossconnect.

Indicators:

Card status.Port status.

ATM E3 Trunk Interface (BNI-E3, LM-3E3)

Line Rate:

34.368 Mbps ± 20 ppm, asynchronous.

Line Code:

HDB3.

Signal Level:

CCITT G.703.

Framing Format:

CCITT G.804, G.832.

Port Interface:

75 ohm unbalanced.

Barrier:

Fully barriered per EN 41003.

ATM Cell Rate:

80,000 cells/sec.

Jitter:

per CCITT G.823

ATM Layer Protocol:

per CCITT I.361 with HEC.

Port Alarm Processing:

AIS.
Loss of Signal.
Remote Alarm Indication.
Loss of Framing.

Line Errors Counted:

BPV.
Parity Bit Errors.

Connector:

75 ohm BNC.

Max. E3 Cable Lengths:

900 feet (275 m.) using specified cable.

Indicators:

Card status.
Port status.

ATM OC3 Trunk Interface (BNI-OC3, LM-OC3

Line Rate:

155.52 Mbps

Line Code:

NRZ

Signal Level:

Max

Min

MMF TX

-8 dBm

-15 dBm

MMF RX

-8 dBm

-28 dBm

SMF LR TX

0 dBm

-5 dBM

SMF LR RX

-10 dBm

-34 dBm

Framing Format:

STS-3c, STM1

Port Interface:

LMI, ILMI

ATM Cell Rate:

353,208 cells/sec.

Jitter:

< 0.01 UI p-p, < 0.1 UI rms

ATM Layer Protocol:

LMI, ILMI

Port Alarm Processing:

LOS, LOF, LOP, Path AIS, Path Yellow

Line Errors Counted:

Section BIP8, Line BIP24, Line FEBE,

Path BIP8, Path FEBE

Connector:

MMF SC

SMF FC/PC

Max. Cable Lengths:

MMF ~ 2 KM

SMF IR ~20 KM

SMF LR ~40 KM

Indicators:

Card status.

Port status.

ATM Service Interface (ASI-1, LM-2T3)

Capacity

2 ports per card.

Interface:

T3

Line Rate:

96,000 cells/sec.

No. of channels per card:

1000

No. of channels per node:

1000 or 5000 (grouped)

VPI Addressing Range:

0-255 (UNI), 0-1023 (NNI_7

VCI Addressing Range:

1-4095

Queues:

32, 16 per line (port) includes CBR, VBR, and ABR queues.

ATM Service Interface (ASI-1, LM-2E3)

Capacity

2 ports per card.

Interface:

E3

Line Rate:

80,000 cells/sec.

No. of channels per card:

1000

No. of channels per node:

1000 or 5000 (grouped)

VPI Addressing Range:

0-255 (UNI), 0-1023 (NNI_

VCI Addressing Range:

1-4095

Queues:

32, 16 per line (port) includes CBR, VBR, and ABR queues.

ATM Service Interface (ASI-2, LM-OC3)

Capacity

2 ports per card.

Interface:

OC3

Line Rate:

353,208 cells/sec.

No. of channels per card:

1000

No. of channels per node:

1000 or 5000 (grouped

VPI Addressing Range:

0-255 (UNI), 0-1023 (NNI_

VCI Addressing Range:

1-4095

Queues:

24, 12 per line (port) includes CBR and VBR queues.

Flat Networks

Number of Nodes:

48 max. (with NPC with 16 M)

63 max. (with NPC or BCC)

Network Capacity:

1008 trunks max.

Node Capacity:

16 FastPacket trunks/node (IPX)

32 ATM trunks/node (BPX) of which 16 can be shelf trunks

Connections per node:

1024 max, or for the BPX, 5000 grouped.

Hops per connection

10 max.

Frame relay ports per node:

127

Structured Networks

Network Size, max.

384 nodes (junction nodes with PCC controllers)

504 nodes (junction nodes with NPC or BCC controllers)

8192 inter-domain virtual circuits max.

Domains per network

8 max.

Nodes per domain

48 max. with PCC in junction nodes

63 max. with NPC and/or BCC in junction nodes

Junction nodes per network

8 max. (with PCC controllers).

32 max. (with NPC or BCC controllers).

Junction nodes per domain

1 minimum, 2 recommended.

Connections per node

junction node

local node

512 inter-domain plus 500 intra-domain

1000 intra-domain

Connections per inter-domain trunk

213 (NTC)

1221 (ATM)

Connections per intra-domain trunk

local trunk

intra-domain jct. trunk


Bandwidth limited only

63

Hops per connection

10 near end local 3 inter-domain 10 far end local max.

Network Synchronization

Network Clock

One clock source per domain must be defined. Network clock cannot propagate across domain boundary.

Node Clock

44.736 MHz, ±50 Hz (Stratum 3 per AT&T Pub 62411). Internal 8 KHz and 192 KHz clocks for synchronizing network interfaces.

Clock Sources:

Internal, free-running oscillator. Phase-locked to any appropriate network interface. External input at T1 or E1 rate.

Clock Output:

Single clock output at T1 or E1 rate for synchronizing co-located IPX node(s) or CPE.

Clocking Hierarchy:

Network-wide or domain-wide (for structured networks) clock selection.

Network Management

NMS Terminal:

SUN Microsystems and StrataCom Rel. 8.2 StrataView Plus, Informix, Wingz, Motif, and HP OpenView software required for network management, Frame Relay connection provisioning, graphical display of network status, statistics gathering and display, and automatic downloading of software.

Control Terminal:

DEC VT100 or equivalent terminal for basic system configuring and alarm monitoring.

Remote Alarm Reporting:

Autodial modem may be connected to one of two control ports on each node for automatic reporting of network alarms.

Remote Diagnostics:

Autoanswer modem may be connected to one of two control ports on each node for remote diagnostic access by StrataCom ISC or other authorized personnel.

Network Control Ports:

Three ports per node, two with RS 232C interface, one with Ethernet LAN interface. (Nodes with PCC controller have only the two RS-232 ports).

Alarm Notification:

Status of all trunks and nodes in network distributed to and stored by each individual node. Reported to StrataView Plus terminal at connecting node.

External Alarms:

Meets Bellcore Compatibility Bulletin #143 and AT&T Technical Reference PUB 43801 DS1 (T1) facility alarm requirements.

Structured Network Management