cc/td/doc/product/wanbu/access/aprod
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Meanings and Values of Parameters Related to LMI Management Frame Relay

Meanings and Values of Parameters Related to LMI Management Frame Relay


Table J-1: Frame Relay LMI Management Parameters
Numbering of packet

0

1

2

3

4

5

6

7

8

Profile number

LMI signalling DLCI

LMI standard

Availability criterion

M 391

M 392

M 393

M 391

M 392

Parameter 1

Meaning:

LMI signalling DLCI.

Possible values:

0 =

DLCI 0

1 =

DLCI 1023.

Parameter 2

Meaning

LMI standard.

Possible values:

0 =

ANSI

T1617. Annex D

1 =

ITU-T.

0433. Annex A

Parameter 3

Meaning:

Availability criteria.

Possible values:

0 =

Fast

One valid polling exchange to deduce the LMI function available

1 =

N393.

Parameter 4

Meaning:

N391 Prior polling cycle (full status polling counter).

Possible values:

1 to 254.

Parameter 5

Meaning:

N392 Error threshold.

Possible values:

1 to 10.

Parameter 6

Meaning:

N394 Monitored event counter (Monitored events count).

Possible values:

1 to 10.

Parameter 7

Meaning:

T391 Status polling time-out (link integrity verification polling timer).

Possible values:

5 to 30 x s.

Parameter 8

Meaning:

T392 Status request wait time-out (Polling verification timer).

Possible values:

5 to 30 x s.