cc/td/doc/product/wanbu/access/aprod
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

Meanings and Values of BSC 3270 Parameters Defined in Class 13

Meanings and Values of BSC 3270 Parameters Defined in Class 13

Parameters displayed

Meaning of parameters

Possible values

1

.

.

BSC 3270 station address

0 to 31

.

32

Programming principle of a BSC 3270 line


Note In the programming example, the stations and the controllers are defined by a control unit number. Each control unit number has fixed addresses which identify the unit in the BSC 3270 protocol frame. See the table below.

Example:


Table F-1: BSC 3270 Addresses
CONTROL UNIT

POLL ADDRESS

SELECT ADDRESS

DEVICE ADDRESS

ASCII EBCDIC ASCII EBCDIC ASCII EBCDIC

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

20

41

42

43

44

45

46

47

48

49

5B

2E

3C

28

2B

21

26

4A

4B

4C

4D

4E

4F

50

51

52

5D

24

2A

29

3B

5E

40

C1

C2

C3

C4

C5

C6

C7

C8

C9

4A

4B

4C

4D

4E

4F

50

D1

D2

D3

D4

D5

D6

D7

D8

D9

5A

5B

5C

5D

5E

5F

2D

2F

53

54

55

56

57

58

59

5A

7C

2C

25

5F

3E

3F

30

31

32

33

34

35

36

37

38

39

3A

23

40

27

3D

22

60

61

E2

E3

E4

E5

E6

E7

E8

E9

6A

6B

6C

6D

6E

6F

F0

F1

F2

F3

F4

F5

F6

F7

F8

F9

7A

7B

7C

7D

7E

7F

20

41

42

43

44

45

46

47

48

49

5B

2E

3C

28

2B

21

26

4A

4B

4C

4D

4E

4F

50

51

52

5D

24

2A

29

3B

5E

40

C1

C2

C3

C4

C5

C6

C7

C8

C9

4A

4B

4C

4D

4E

4F

50

D1

D2

D3

D4

D5

D6

D7

D8

D9

5A

5B

5C

5D

5E

5F


Figure F-1: Programming a BSC 3270 Line

Profiles of class 12:

Programming of line 8 on FastPad (1) side:

  Parameter 90 = 02 (number of controllers)
  Parameter 91 = 43 (position of 1st controller)

Class 19 controller table:

· Class 19 parameter 42 (1st controller):

1st byte:

03 (No. of auto-call), see class 8

2nd byte:

00 (1st controller address)

3rd byte:

04 (number of stations)

4th byte:

13 (position of 1st station),

class 13: extension line connection

parameters (recurrence 8)

Profile 60 (BSC 3270):

Parameter 13-11

Parameter 14-12

Parameter 15-13

Parameter 16-14

· Class 19 parameter 43 (2nd controller):

1st byte:

03 (No. of auto-call), see class 8

2nd byte:

01 (2nd controller address)

3rd byte:

03 (number of stations)

4th byte:

07 (position of 1st station),

parameter 7-21

parameter 8-22

parameter 9-23

  parameter 90 = 02 (number of controllers)
  parameter 91 = 43 (position of 1st controller).

hometocprevnextglossaryfeedbacksearchhelp
Posted: Thu Jan 25 14:14:30 PST 2001
All contents are Copyright © 1992--2001 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.