Table Of Contents
Configuring System Engine Parameters
Configuring Application Parameters
Configuring Multiple Triggers for an Application
Port Sharing Among Multiple Triggers
Displaying NTP Server Information
Configuring an External Syslog Server
Configuring the Clock Time Zone
Advanced Configuration
This chapter describes advanced configuration procedures for modifying application parameters after the initial installation and configuration process described in the section, "Configuring System Components" on page 63. That earlier chapter includes commands not described in this chapter.
The advanced configuration procedures include:
• Configuring System Engine Parameters
• Configuring Application Parameters
• Configuring Multiple Triggers for an Application
• Configuring an External Syslog Server
• Configuring the Clock Time Zone
Configuring System Engine Parameters
Use this procedure to configure parameters that are used across all systems and subsystems in Cisco Unity Express. This set of parameters affects the underlying software programs, or engine, that comprise Cisco Unity Express.
Only the parameter maxsteps is available. A script uses this value to limit the number of steps that can execute for an application script. For example, if a script has an error such that a customer is returned to the same menu choice in an infinite loop, the system stops the loop when the maxstep value is reached. Similarly, if a script has procedures with nested steps that exceed the maxstep value when the script executes, the system stops the script. When this happens, the caller hears a system message that the system is not available.
Note Script steps are described in detail in the Cisco Unity Express Script Editor Guide.
Prerequisites
The following information is required to configure system engine parameters.
•Maximum number of times a script step can execute before an alternate path is invoked.
SUMMARY STEPS
1. config t
2. ccn engine
3. default parameter
4. maxsteps steps-limit
5. end
6. exit
7. show ccn engine
8. copy running-config startup-config
DETAILED STEPS
Command or Action PurposeStep 1
config t
Example:se-10-0-0-0# config t
Enters configuration mode.
Step 2
ccn engine
Example:se-10-0-0-0(config)# ccn engine
Enters Cisco Communication Network engine configuration mode.
Step 3
default parameter
Example:se-10-0-0-0(config-engine)# default maxsteps
(Optional) Sets the parameter to the system default value. The default value for maxsteps is 1000.
Step 4
maxsteps steps-limit
Example:se-10-0-0-0(config-engine)# maxsteps 200
Specifies the maximum number of steps in the telephony application. Refer to the Cisco Unity Express Script Editor Guide for detailed information about script steps.
Step 5
end
Example:se-10-0-0-0(config-engine)# end
Exits Cisco Communication Network engine configuration mode.
Step 6
exit
Example:se-10-0-0-0(config)# exit
Exits configuration mode.
Step 7
show ccn engine
Example:se-10-0-0-0# show ccn engine
Displays configured Cisco Communication Network engine parameters.
Step 8
copy running-config startup-config
Example:se-10-0-0-0# copy running-config startup-config
Copies the configuration changes to the startup configuration.
Examples
The following example illustrates the show ccn engine output:
se-10-0-0-0# show ccn engine
Maximum number of Tasks: 0
Maximum number of Steps: 200
se-10-0-0-0#
Configuring Application Parameters
The section, "Configuring System Components" on page 63 described how to configure parameters for the applications that shipped with Cisco Unity Express. This procedure describes how to configure parameters for your custom auto-attendant application script.
Prerequisites
•Application name.
•Script name for the application.
•Maxsessions value. See the section "Sharing Ports Among Applications and Triggers" on page 66.
•Name and value for each parameter that the script requires. These may vary, depending on the script that you have created.
Note For more information about creating scripts, refer to the Cisco Unity Express Script Editor Guide.
SUMMARY STEPS
1. config t
2. ccn application full-name
3. default parameter
4. description "text"
5. maxsessions number
6. no parameter
7. parameter name "value"
8. script name [description "description"]
9. enabled
10. end
11. exit
12. show ccn scripts
13. show ccn application
14. copy running-config startup-config
DETAILED STEPS
Command or Action PurposeStep 1
config t
Example:se-10-0-0-0# config t
Enters configuration mode.
Step 2
ccn application full-name
Example:se-10-0-0-0(config)# ccn application myscript
Specifies the application to configure and enters application configuration mode. Use the full name of the application for the full-name argument.
Step 3
default parameter
Example:se-10-0-0-0(config-application)# default maxsessions
(Optional) Resets the application parameter as follows:
•default description—Uses the name of the application.
•default enabled—Enables the application.
•default maxsessions—Uses the number of ports on your Cisco Unity Express module. See Table 2 on page 15 or Table 4 on page 16 for the maximum number of ports.
•default script—No effect.
•default parameter—Uses the script's default value.
Step 4
description "text"
Example:se-10-0-0-0(config-application)# description "my application"
(Optional) Enter a description of the application. Use double quotes around the text.
Step 5
maxsessions number
Example:se-10-0-0-0(config-application)# maxsessions 5
Specifies the number of users who can access this application simultaneously. See "Port Sharing Among Multiple Triggers" for guidelines on assigning this value.
Step 6
no parameter
Example:se-10-0-0-0(config-application)# no description
(Optional) Deletes or disables a script value.
Step 7
parameter name "value"
Example:se-10-0-0-0(config-application)# parameter MaxRetry "4"
se-10-0-0-0(config-application)# parameter WelcomePrompt "Welcome.wav"
Specifies parameters for the application. Each parameter must have a name and a value, which is written within double quotes.
Step 8
script name [description "description"]
Example:se-10-0-0-0(config-application)# script myscript.aef description "My New Script"
Specifies the name of the script and an optional description, which must be written within double quotes. If no description is provided, the system uses the name value for the description.
Step 9
enabled
Example:se-10-0-0-0(config-application)# enabled
Allows the application to be accessible to the system.
Step 10
end
Example:se-10-0-0-0(config-application)# end
Exits application configuration mode.
Step 11
exit
Example:se-10-0-0-0(config)# exit
Exits configuration mode.
Step 12
show ccn scripts
Example:se-10-0-0-0# show ccn scripts
Displays the configured script names and their descriptions.
Step 13
show ccn application
Example:se-10-0-0-0# show ccn application
Displays details about each configured application.
Step 14
copy running-config startup-config
Example:se-10-0-0-0# copy running-config startup-config
Copies the configuration changes to the startup configuration.
Examples
The following example illustrates the show ccn scripts output:
se-10-0-0-0# show ccn scripts
Name: myscript.aef
Description: My New Script
se-10-0-0-0#
The following example illustrates the show ccn application output:
se-10-0-0-0# show ccn application
Name: myscript
Description: my application
Script: myscript.aef
ID number: 2
Enabled: yes
Maximum number of sessions: 5
Retries: 4
WelcomePrompt: Welcome.wav
se-10-0-0-0#
Configuring Multiple Triggers for an Application
Your network may require additional triggers for one or more Cisco Unity Express applications. For example, customers may be able to dial more than one telephone number to contact your company. These telephone numbers would activate the auto-attendant application.
Use this procedure to configure the additional triggers. The trigger must match a dial peer configured on Cisco CME. If you configure a trigger on Cisco Unity Express, verify that the dial peer exists in Cisco CME.
Cisco Unity Express supports a maximum of 8 triggers for all applications combined. This applies to both the NM and the AIM.
Port Sharing Among Multiple Triggers
Each trigger is assigned a maxsessions value. In addition to the guidelines described in "Port Sharing Among Multiple Triggers", one other consideration is needed.
The maximum number of callers that can access an application concurrently is determined by the application's maxsession value if the total maxsessions values from all its triggers exceeds the application's maxsessions value.
For example, suppose your module has 8 ports and you assigned the auto-attendant application a maxsessions value of 5. Your auto-attendant application has 2 triggers. You configure one trigger with a maxsessions value of 2 and the other trigger with a maxsessions value of 4. The maximum number of callers that can access the auto-attendant application simultaneously is 5, not 6.
Suppose, instead, that you configure one trigger with a maxsessions value of 2 and the other trigger with a maxsessions value of 2. The maximum number of simultaneous callers to the application is 4, not 5.
Prerequisites
The following information is required to configure the triggers:
•Telephone number that invokes the application. The number must not be the same for voice-mail, auto-attendant, and the greeting management system.
•Number of milliseconds that the system must wait for a caller response before it times out and drops the call.
•Language to use for the prompts. Cisco Unity Express supports only one language installed on the system. This option cannot be changed.
•Maximum number of callers, or sessions, that the application can handle simultaneously. The total for all applications must not exceed the maximum number of ports for the system. (See Table 2 on page 15 or Table 4 on page 16 for the maximum number of ports.) The applications need not have the same maximum number; for example, voice mail might need three sessions, while auto attendant needs five sessions.
SUMMARY STEPS
1. config t
2. ccn trigger sip phonenumber number
3. application string
4. default parameter
5. idletimeout time
6. locale language
7. maxsessions number
8. no parameter
9. enabled
10. end
11. Repeat Step 2 to Step 10 to configure additional triggers for this application.
12. exit
13. show ccn trigger
14. copy running-config startup-config
DETAILED STEPS
Command or Action PurposeStep 1
config t
Example:se-10-0-0-0# config t
Enters configuration mode.
Step 2
ccn trigger sip phonenumber number
Example:se-10-0-0-0(config)# ccn trigger sip phonenumber 50150
se-10-0-0-0(config)# ccn trigger sip phonenumber 50160
Specifies the telephone number that acts as the trigger to start the application and enters trigger configuration mode. The number value must match a dial peer configured on Cisco CME.
Step 3
application string
Example:se-10-0-0-0(config-trigger)# application myapplication
Specifies the name of the application to start when the telephone number is dialed, which, in turn, invokes the appropriate application script. This application name must match the name that was configured with the ccn application name command.
Step 4
default parameter
Example:se-10-0-0-0(config-trigger)# default idletimeout
(Optional) Resets the application parameter to the script-defined default value. Using the default command on Cisco Unity Express system parameters has the following effects:
•default application—No effect.
•default enabled—Enables the application.
•default idletimeout—Uses 5000 (5 seconds).
•default locale—Uses the system default.
•default maxsessions—Uses the number of ports on your Cisco Unity Express module. See Table 2 on page 15 or Table 4 on page 16 for the maximum number of ports.
Step 5
idletimeout time
Example:se-10-0-0-0(config-trigger)# idletimeout 500
Specifies the number of milliseconds to wait for a caller's response before timing out and disconnecting the call.
Step 6
locale language
Example:se-10-0-0-0(config-trigger)# locale en_US
Specifies the language to use for the prompts heard by the caller. Cisco Unity Express supports only one language installed on the system. This option cannot be changed.
Step 7
maxsessions number
Example:se-10-0-0-0(config-trigger)# maxsessions 3
Specifies the maximum number of callers the application can handle simultaneously. See "Port Sharing Among Multiple Triggers" for guidelines on assigning this value.
Step 8
no parameter
Example:se-10-0-0-0(config-trigger)# no maxsessions
(Optional) Deletes or disables the parameter value. Using the no command on Cisco Unity Express system parameters has the following effects:
•no application—No effect.
•no enabled—Disables the application.
•no idletimeout—No effect.
•no locale—Uses the system default.
•no maxsessions—Sets the value to 0.
Step 9
enabled
Example:se-10-0-0-0(config-trigger)# enabled
Enables the trigger.
Step 10
end
Example:se-10-0-0-0(config-trigger)# end
Exits trigger configuration mode.
Step 11
Repeat Step 2 to Step 10 to configure additional triggers for this application.
—
Step 12
exit
Example:se-10-0-0-0(config)# exit
Exits configuration mode.
Step 13
show ccn trigger
Example:se-10-0-0-0# show ccn trigger
Displays the parameter values for all configured triggers.
Step 14
copy running-config startup-config
Example:se-10-0-0-0# copy running-config startup-config
Copies the configuration changes to the startup configuration.
Examples
The following sample configuration sets two triggers for the voice-mail application:
se-10-0-0-0# config t
se-10-0-0-0(config)# ccn trigger sip phonenumber 50150
se-10-0-0-0(config-trigger)# application voicemail
se-10-0-0-0(config-trigger)# idletimeout 500
se-10-0-0-0(config-trigger)# maxsessions 4
se-10-0-0-0(config-trigger)# enabled
se-10-0-0-0(config-trigger)# end
se-10-0-0-0(config)#
se-10-0-0-0(config)# ccn trigger sip phonenumber 50160
se-10-0-0-0(config-trigger)# application voicemail
se-10-0-0-0(config-trigger)# idletimeout 1000
se-10-0-0-0(config-trigger)# maxsessions 8
se-10-0-0-0(config-trigger)# enabled
se-10-0-0-0(config-trigger)# end
se-10-0-0-0(config)# exit
se-10-0-0-0#
The output for the show ccn trigger command might look similar to the following:
se-10-0-0-0# show ccn trigger
Name: 50150
Type: SIP
Application: voicemail
Locale: en_US
Idle Timeout: 500
Enabled: yes
Maximum number of sessions: 4
Name: 50160
Type: SIP
Application: voicemail
Locale: en_US
Idle Timeout: 1000
Enabled: yes
Maximum number of sessions: 8
se-10-0-0-0#
Configuring the Hostname
During the software postinstallation process, the hostname was configured. Use this procedure to change the hostname.
SUMMARY STEPS
1. config t
2. hostname hostname
3. exit
4. show hosts
5. copy running-config startup-config
DETAILED STEPS
Examples
The following commands configure the hostname:
se-10-0-0-0# config t
se-10-0-0-0(config)# hostname ca-west
ca-west(config)# exit
ca-west#
The output from the show hosts command might look similar to the following:
ca-west# show hosts
Hostname: ca-west
Domain: myoffice
DNS Server1: 10.100.10.130
DNS Server2: 10.5.0.0
ca-west#
Configuring the DNS Server
During the software postinstallation process, the DNS server and IP addresses were configured. Use this procedure to change the server name and IP addresses.
SUMMARY STEPS
1. config t
2. ip domain-name dns-server-name
3. ip name-server ip-address [ip-address] [ip-address] [ip-address]
4. exit
5. show ip route
6. copy running-config startup-config
DETAILED STEPS
Examples
The following commands configure the DNS server:
se-10-0-0-0# config t
se-10-0-0-0(config)# ip domain-name myoffice
se-10-0-0-0(config)# ip name-server 10.100.10.130 10.5.0.0
se-10-0-0-0(config)# exit
se-10-0-0-0#
The output from the show ip route command might look similar to the following:
se-10-0-0-0# show ip route
DEST GATE MASK IFACE
10.100.6.9 0.0.0.0 255.255.255.0 eth1
172.16.0.0 0.0.0.0 255.0.0.0 lo
0.0.0.0 10.100.6.9 0.0.0.0 eth1
se-10-0-0-0#
Configuring NTP Servers
You can configure Network Time Protocol (NTP) servers using the GUI options, the CLI commands, or during the software postinstallation process. Cisco Unity Express accepts a maximum of three NTP servers. Use this procedure to add or delete NTP servers.
Adding NTP Servers
You can designate an NTP server using its IP address or its hostname.
•If you use an IP address, you must always refer to the NTP server by that IP address. You cannot use a hostname to refer to that NTP server.
•If you use a hostname, you must always refer to the NTP server by that hostname. You cannot use an IP address to refer to that NTP server.
Cisco Unity Express uses the DNS server to resolve the hostname to an IP address and stores the IP address as an NTP server. If DNS resolves the hostname to more than one IP address, Cisco Unity Express randomly chooses one of the IP addresses that is not already designated as an NTP server.
To configure an NTP server with multiple IP addresses for a hostname, repeat the configuration steps using the same hostname. Each iteration assigns the NTP server to its remaining IP addresses.
SUMMARY STEPS
1. config t
2. ntp server {hostname | ip-address} [prefer]
3. exit
4. show ntp status
5. show ntp configuration
6. copy running-config startup-config
DETAILED STEPS
Examples
The following commands configure the NTP server:
se-10-0-0-0# config t
se-10-0-0-0(config)# ntp server 10.100.6.9
se-10-0-0-0(config)# exit
se-10-0-0-0#
The output from the show ntp status command might look similar to the following:
se-10-0-0-0# show ntp status
NTP reference server 1: 10.100.6.9
Status: sys.peer
Time difference (secs): 3.268110099434328E8
Time jitter (secs): 0.1719226837158203
se-10-0-0-0#
The following example configures an NTP server with a hostname that points to two IP addresses 172.16.10.1 and 172.16.10.2:
se-10-0-0-0# config t
se-10-0-0-0(config)# ntp server NTP.mine.com
se-10-0-0-0(config)# exit
se-10-0-0-0#
se-10-0-0-0# config t
se-10-0-0-0(config)# ntp server NTP.mine.com
se-10-0-0-0(config)# exit
se-10-0-0-0#
The output from the show ntp status command might look similar to the following:
se-10-0-0-0# show ntp status
NTP reference server 1: 172.16.10.1
Status: sys.peer
Time difference (secs): 3.268110099434328E8
Time jitter (secs): 0.1719226837158203
NTP reference server 1: 172.16.10.2
Status: sys.peer
Time difference (secs): 3.268110099434328E8
Time jitter (secs): 0.1719226837158203
se-10-0-0-0#
Removing an NTP Server
Remove an NTP server using its IP address or hostname.
•If the NTP server was configured using its IP address, use that IP address to remove the server. You cannot remove the server with its hostname.
•If the NTP server was configured using its hostname, use that hostname to remove the server. You cannot remove the server with an IP address.
If the NTP server hostname is associated with more than one IP address, you cannot specify which IP address to remove. Cisco Unity Express deletes the IP address based on a response from the DNS server and cannot guarantee which configured NTP server IP address is deleted.
If you need to remove the NTP server with a specific IP address, repeat the removal steps enough times to delete all the NTP servers, update the DNS server with the correct IP address information, and then add the NTP server enough times to assign the NTP server to its appropriate number of IP addresses.
SUMMARY STEPS
1. config t
2. no ntp server {hostname | ip-address} [prefer]
3. exit
4. show ntp status
5. show ntp configuration
6. copy running-config startup-config
DETAILED STEPS
Displaying NTP Server Information
The following commands are available to display NTP server configuration information and status:
•show ntp associations
•show ntp server
•show ntp source
Configuring an External Syslog Server
Cisco Unity Express captures messages that describe activities in the system. Use CLI commands to display the messages; viewing the messages is not available from the GUI.
The activities are categorized into four different levels of severity with regard to their impact on the system's functioning:
•Information—The message describes normal system activity, including debug, information, and notice messages.
•Warning—The message is an alert that a non-normal activity is occurring. The Cisco Unity Express system continues to function.
•Error—The message indicates that a system error has occurred. The Cisco Unity Express system may or may not have stopped functioning.
•Fatal—The message describes a critical, alert, or emergency situation with the system. The Cisco Unity Express system has stopped functioning.
These messages are collected and directed to three possible destinations:
•Messages.log file—This option is the default. The file contains all system messages and resides on the Cisco Unity Express module hard disk in /var/log/messages.log. You can print the messages, view them on the console, or copy them to a server to review for troubleshooting and error reporting.
•Console—Display the messages.log file using the show log name messages.log command. View the system messages as they occur with the log console info command.
•External system log (syslog) server—Cisco Unity Express copies the messages to another server and collects them in a file on that server's hard disk. The syslog daemon configuration on the external server determines which directory will save the messages log.
The external server must be configured to listen for UDP on port 514 from the IP address of the Cisco Unity Express module.
Prerequisites
You need the hostname or IP address of the designated log server.
SUMMARY STEPS
1. config t
2. log server address {hostname | IP-address}
3. exit
4. show running-config
DETAILED STEPS
Examples
The output from the show running-config command might look similar to the following:
se-10-0-0-0# show running-config
clock timezone America/Los_Angeles
hostname se-10-0-0-0
ip domain-name localdomain
ntp server 10.100.60.1
.
.
.
log server address 10.100.10.210
voicemail default mailboxsize 3000
voicemail capacity time 6000
end
Configuring the Clock Time Zone
During the software postinstallation process, the time zone of the local Cisco Unity Express module was configured. Use this procedure to change the module's time zone.
Cisco Unity Express automatically updates the clock for daylight savings time on the basis of the selected time zone.
SUMMARY STEPS
1. config t
2. clock timezone timezone
3. exit
4. show clock detail
5. copy running-config startup-config
DETAILED STEPS
Examples
The following commands configure the clock time zone:
se-10-0-0-0# config t
se-10-0-0-0(config)# clock timezone
Please identify a location so that time zone rules can be set correctly.
Please select a continent or ocean.
1) Africa 4) Arctic Ocean 7) Australia 10) Pacific Ocean
2) Americas 5) Asia 8) Europe
3) Antarctica 6) Atlantic Ocean 9) Indian Ocean
#? 2
Please select a country.
1) Anguilla 18) Ecuador 35) Paraguay
2) Antigua & Barbuda 19) El Salvador 36) Peru
3) Argentina 20) French Guiana 37) Puerto Rico
4) Aruba 21) Greenland 38) St Kitts & Nevis
5) Bahamas 22) Grenada 39) St Lucia
6) Barbados 23) Guadeloupe 40) St Pierre & Miquelon
7) Belize 24) Guatemala 41) St Vincent
8) Bolivia 25) Guyana 42) Suriname
9) Brazil 26) Haiti 43) Trinidad & Tobago
10) Canada 27) Honduras 44) Turks & Caicos Is
11) Cayman Islands 28) Jamaica 45) United States
12) Chile 29) Martinique 46) Uruguay
13) Colombia 30) Mexico 47) Venezuela
14) Costa Rica 31) Montserrat 48) Virgin Islands (UK)
15) Cuba 32) Netherlands Antilles 49) Virgin Islands (US)
16) Dominica 33) Nicaragua
17) Dominican Republi 34) Panama
#? 45
Please select one of the following time zone regions.
1) Eastern Time
2) Eastern Time - Michigan - most locations
3) Eastern Time - Kentucky - Louisville area
4) Eastern Time - Kentucky - Wayne County
5) Eastern Standard Time - Indiana - most locations
6) Eastern Standard Time - Indiana - Crawford County
7) Eastern Standard Time - Indiana - Starke County
8) Eastern Standard Time - Indiana - Switzerland County
9) Central Time
10) Central Time - Michigan - Wisconsin border
11) Central Time - North Dakota - Oliver County
12) Mountain Time
13) Mountain Time - south Idaho & east Oregon
14) Mountain Time - Navajo
15) Mountain Standard Time - Arizona
16) Pacific Time
17) Alaska Time
18) Alaska Time - Alaska panhandle
19) Alaska Time - Alaska panhandle neck
20) Alaska Time - west Alaska
21) Aleutian Islands
22) Hawaii
#? 16
The following information has been given:
United States
Pacific Time
Therefore TZ='America/Los_Angeles' will be used.
Is the above information OK?
1) Yes
2) No
#? 1
The output from the show clock detail command might look similar to the following:
se-10-0-0-0# show clock detail
19:20:33.724 PST Wed Feb 4 2004
time zone: America/Los_Angeles
clock state: unsync
delta from reference (microsec): 0
estimated error (microsec): 175431
time resolution (microsec): 1
clock interrupt period (microsec): 10000
time of day (sec): 732424833
time of day (microsec): 760817
Posted: Fri Jan 13 04:48:18 PST 2006
All contents are Copyright © 1992--2006 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.