These sections describe the technical specifications and safety approvals of the DPA 7630:
Table A-1 includes the physical and operating specifications of the DPA 7630.
Specification | Value or Range |
---|---|
Dimensions (HxWxD) | 1.75 x 17.25 x 15.5 inches |
Weight | 5.2kg (11lbs 8oz) |
Power | 100-240 VAC, 50-60 Hz |
Processor | 50 MHz MPC 860T |
Operating environment | 0° to 40° C (32° to 104° F) |
Operating humidity | 10% to 95% (noncondensing) |
Nonoperating environment | -10° to 60° C (14° to 140° F) |
The DPA 7630 includes the following ports:
These sections describe the port pinouts on the DPA 7630:
Table A-2 describes the telco port connecto pinouts.
Pin Number | Function |
---|---|
1, 26 | Unused |
2, 27 | Port 1 receive |
3, 28 | Port 1 transmit |
4,29 | Unused |
5, 30 | Port 2 receive |
6,31 | Port 2 transmit |
7, 32 | Unused |
8, 33 | Port 3 receive |
9, 34 | Port 3 transmit |
10, 35 | Unused |
11, 36 | Port 4 receive |
12, 37 | Port 4 transmit |
13, 38 | Unused |
14, 39 | Port 5 receive |
15, 40 | Port 5 transmit |
16, 41 | Unused |
17, 42 | Port 6 receive |
18, 43 | Port 6 transmit |
19, 44 | Unused |
20, 45 | Port 7 receive |
21, 46 | Port 7 transmit |
22, 47 | Unused |
23, 48 | Port 8 receive |
24, 49 | Port 8 transmit |
25, 50 | Unused |
Table A-3 describes the Ethernet port connector pinouts.
Pin Number | Function |
---|---|
1 | TD+ |
2 | TD- |
3 | RD+ |
4 | |
5 | |
6 | RD- |
7 | |
8 | |
Table A-4 describes the console port connector pinouts.
Pin Number | Function |
---|---|
1, 8 | Connected |
2 | DTR |
3 | TxD |
4,5 | Ground |
6 | RxD |
7 | DSR |
The DPA 7630 meets the following regulatory safety and compliance approvals:
Caution Warning: This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. |
Caution Hungarian Class A Warning: This equipment is a class A product and should be used and installed properly according to the Hungarian EMC Class A requirements (MSZEN55022), the Class A equipment are derived for typical commercial establishments for which special conditions of installation and protection distance are used. |
Taiwan (BSMI)
Japan (VCCI)
Posted: Thu Dec 14 09:24:14 PST 2000