Installing the Cisco ATA


This section provides instructions for installing the Cisco ATA 186 and Cisco ATA 188. Before you perform the installation, be sure you have met the following prerequisites:

Planned the network and Cisco ATA configuration.

Installed the Ethernet connection.

Installed and configured the other network devices.

This section contains the following topics:

Network Requirements

Safety Recommendations

What the Cisco ATA Package Includes

What You Need

Installation Procedure

Power-Down Procedure


Note The term Cisco ATA is used throughout this manual to refer to both the Cisco ATA 186 and the Cisco ATA 188, unless differences between the Cisco ATA 186 and Cisco ATA 188 are explicitly stated.


Network Requirements

The Cisco ATA acts as an endpoint on an IP telephony network. The following equipment is required:

Call Control system

Voice packet gateway—Required if you are connecting to the Public Switched Telephone Network (PSTN). A gateway is not required if an analog key system is in effect.

Ethernet connection

Safety Recommendations

To ensure general safety, follow these guidelines:

Do not get this product wet or pour liquids into this device.

Do not open or disassemble this product.

Do not perform any action that creates a potential hazard to people or makes the equipment unsafe.

Use only the power supply that comes with the Cisco ATA.


Warning Ultimate disposal of this product should be handled according to all national laws and regulations.



Warning Read the installation instructions before you connect the system to its power source.



Warning The plug-socket combination must be accessible at all times because it serves as the main disconnecting device.



Warning Do not work on the system or connect or disconnect cables during periods of lightning activity.



Warning To avoid electric shock, do not connect safety extra-low voltage (SELV) circuits to telephone-network voltage (TNV) circuits. LAN ports contain SELV circuits, and WAN ports contain TNV circuits. Some LAN and WAN ports both use RJ-45 connectors. Use caution when connecting cables.


For translated warnings, see the Regulatory Compliance and Safety Information for the Cisco ATA 186 and Cisco ATA 188 manual.

What the Cisco ATA Package Includes

The Cisco ATA package contains the following items:

Cisco ATA 186 or Cisco ATA 188 Analog Telephone Adaptor

Cisco ATA 186 and Cisco ATA 188 Analog Telephone Adaptor at a Glance

Regulatory Compliance and Safety Information for the Cisco ATA 186 and Cisco ATA 188

5V power adaptor

Power cord


Note The Cisco ATA is intended for use only with the 5V DC power adaptor that comes with the unit.


What You Need

You also need the following items:

Category-3 10BASE-T or 100BASE-T or better Ethernet cable. One cable is needed for each Ethernet connection.

A Category-3 Ethernet cable supports 10BASE-T for up to 100 meters without quality degradation, and a Category-3 Ethernet cable supports 100BASE-T for up to 10 meters without quality degradation.

For uplink connections, use a crossover Ethernet cable to connect the Cisco ATA to another Ethernet device (such as a router or PC) without using a hub. Otherwise, use straight-through Ethernet cables for both uplink and data port connections.

Access to an IP network

One or two analog Touch-Tone telephones or fax machines, or one of each

Installation Procedure

After the equipment is in place, see Figure 2-1 (for Cisco ATA 186) or Figure 2-2 (for Cisco ATA 188) and follow the next procedure to install the Cisco ATA.

Figure 2-1 Cisco ATA 186 Rear Panel Connections

Figure 2-2 Cisco ATA 188 Rear Panel Connections

Procedure


Step 1 Place the Cisco ATA near an electrical power outlet.

Step 2 Connect one end of a telephone line cord to the Phone 1 input on the rear panel of the Cisco ATA. Connect the other end to an analog telephone set.

If you are connecting a telephone set that was previously connected to an active telephone line, unplug the telephone line cord from the wall jack and plug it into the Phone 1 input.


Warning To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord.



Caution Do not connect the Phone input ports to a telephone wall jack. To avoid damaging the Cisco ATA or telephone wiring in the building, do not connect the Cisco ATA to the telecommunications network. Connect the Phone port to a telephone only, never to a telephone wall jack.

Note The telephone must be switched to tone setting (not pulse) for the Cisco ATA to operate properly.


Step 3 (Optional) Connect the telephone line cord of a second telephone to the Phone 2 input port.


Note If you are connecting only one telephone to the Cisco ATA, you must use the Phone 1 input port.


Step 4 Connect an Ethernet cable to the uplink RJ-45 connector on the Cisco ATA. For the Cisco ATA 186, this is the 10BASE-T connector; for the Cisco ATA 188, this is the 10/100UPLINK connector.


Note Use a crossover Ethernet cable to connect the Cisco ATA to another Ethernet device (such as a router or PC) without using a hub. Otherwise, use a straight-through Ethernet cable.


Step 5 (Cisco ATA 188 only—optional) Connect a straight-through Ethernet cable from your PC to the 10/100 PC RJ-45 connector on the Cisco ATA.

Step 6 Connect the socket end of the power cord to the Cisco-supplied 5V DC power adaptor.

Step 7 Insert the power adaptor cable into the power connector on the Cisco ATA.


Caution Use only the Cisco-supplied power adaptor.

Warning This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure that a fuse or circuit breaker no larger than 120 VAC, 15A U.S. (240VAC, 10A international) is used on the phase conductors (all current-carrying conductors).


Step 8 Connect the plug end of the 5V DC power adaptor cord into an electrical power outlet.

When the Cisco ATA is properly connected and powered up, the green activity LED flashes to indicate network activity. This LED is labeled ACT on the rear panel of the Cisco ATA 186 and is labeled LINK on the rear panel of the Cisco ATA 188.


Caution Do not cover or block the air vents on either the top or the bottom surface of the Cisco ATA. Overheating can cause permanent damage to the unit.

For more information about LEDs and the function button, see the "Hardware Overview" section.


Power-Down Procedure


Caution If you need to power down Cisco ATA 186 or Cisco 188 at any time, use the following power-down procedure to prevent damage to the unit.

Procedure


Step 1 Unplug the RJ45 Ethernet cable

Step 2 Wait for 20 seconds.

Step 3 Unplug the power cable.



Warning This equipment contains a ring signal generator (ringer), which is a source of hazardous voltage. Do not touch the RJ-11 (phone) port wires (conductors), the conductors of a cable connected to the RJ-11 port, or the associated circuit-board when the ringer is active. The ringer is activated by an incoming call.