Table 2-1 through Table 2-5 provide R2 signaling information based on ITU Q.441 as it applies specifically to the Venezuela telephone network.


Table 2-1: R2 Signaling Group I Forward Signals
Token Data Field Designation Frequencies Digit Meaning

1

G-I-1

1380 + 1500 Hz

Digit 1

2

G-I-2

1380 + 1620 Hz

Digit 2

3

G-I-3

1500 + 1620 Hz

Digit 3

4

G-I-4

1380 + 1740 Hz

Digit 4

5

G-I-5

1500 + 1740 Hz

Digit 5

6

G-I-6

1620 + 1740 Hz

Digit 6

7

G-I-7

1380 + 1860 Hz

Digit 7

8

G-I-8

1500 + 1860 Hz

Digit 8

9

G-I-9

1620 + 1860 Hz

Digit 9

10

G-I-10

1740 + 1860 Hz

Digit 0

11

G-I-11

1380 + 1980 Hz

Not applicable

12

G-I-12

1500 + 1980 Hz

Request not accepted (exchange without ANUM)

13

G-I-13

1620 + 1980 Hz

Not applicable

14

G-I-14

1749 + 1980 Hz

Access to announcement

15

G-I-15

1860 + 1980 Hz

End of number


Table 2-2: R2 Signaling Group II Forward Signals
Token Data Field Designation Frequencies Meaning

1

G-II-1

1380 + 1500 Hz

Subscriber without priority

2

G-II-2

1380 + 1620 Hz

Subscriber with priority

3

G-II-3

1500 + 1620 Hz

Test equipment

4

G-II-4

1380 + 1740 Hz

Coin box

5

G-II-5

1500 + 1740 Hz

Operator

6

G-II-6

1620 + 1740 Hz

Data transmission

7

G-II-7

1380 + 1860 Hz

Redirect call

8

G-II-8

1500 + 1860 Hz

Not applicable

9

G-II-9

1620 + 1860 Hz

Not applicable

10

G-II-10

1740 + 1860 Hz

Not applicable

11

G-II-11

1380 + 1980 Hz

Not applicable

12

G-II-12

1500 + 1980 Hz

Not applicable

13

G-II-13

1620 + 1980 Hz

Not applicable

14

G-II-14

1740 + 1980 Hz

Not applicable

15

G-II-15

1860 + 1980 Hz

Not applicable


Table 2-3: R2 Signaling Group A Backward Signals
Token Data Field Designation Frequencies Meaning

1

A-1

1140 + 1020 Hz

Send next BNUM digit (n + 1)

2

A-2

1140 + 900 Hz

Send previous digit (n - 1)

3

A-3

1020 + 900 Hz

Number complete send category; change over to reception of Group B signals

4

A-4

1140 + 780 Hz

Network congestion

5

A-5

1020 + 780 Hz

Send category only

6

A-6

900 + 780 Hz

Number complete charge, set up voice path

7

A-7

1140 + 660 Hz

Send second previous digit (n - 2)

8

A-8

1020 + 660 Hz

Send third previous digit (n - 3)

9

A-9

900 + 660 Hz

Send next ANUM digit (n + 1)

10

A-10

780 + 660 Hz

Not applicable

11

A-11

1140 + 540 Hz

Not applicable

12

A-12

1020 + 540 Hz

Not applicable

13

A-13

900 + 540 Hz

Not applicable

14

A-14

780 + 540 Hz

Not applicable

15

A-15

660 + 540 Hz

Not applicable


Table 2-4: R2 Signaling Group B Backward Signals
Token Data Field Designation Frequencies Meaning

1

B-1

1140 + 1020 Hz

Subscriber line free with charge

2

B-2

1140 + 900 Hz

Number changed

3

B-3

1020 + 900 Hz

Busy

4

B-4

1140 + 780 Hz

Congestion

5

B-5

1020 + 780 Hz

Unallocated number

6

B-6

900 + 780 Hz

Line free with charging

7

B-7

1140 + 660 Hz

Line free, no charge

8

B-8

1020 + 660 Hz

Line barred to incoming traffic

9

B-9

900 + 660 Hz

Subscriber line intercepted

10

B-10

780 + 660 Hz

Data transmission

11

B-11

1140 + 540 Hz

Not applicable

12

B-12

1020 + 540 Hz

Not applicable

13

B-13

900 + 540 Hz

Not applicable

14

B-14

780 + 540 Hz

Not applicable

15

B-15

660 + 540 Hz

Not applicable


Table 2-5: R2 Signaling Group C Backward Signals
Token Data Field Designation Frequencies Meaning

1

C-1

1140 + 1020 Hz

Send next BNUM digit (n + 1)

2

C-2

1140 + 900 Hz

Send previous digit (n - 1)

3

C-3

1020 + 900 Hz

Number complete send category; change over to reception of Group B signals

4

C-4

1140 + 780 Hz

Network congestion

5

C-5

1020 + 780 Hz

Send category only

6

C-6

900 + 780 Hz

Number complete charge, set up voice path

7

C-7

1140 + 660 Hz

Send second previous digit (n - 1)

8

C-8

1020 + 660 Hz

Send third previous digit (n - 2)

9

C-9

900 + 660 Hz

Send next ANUM digit (n + 1)

10

C-10

780 + 660 Hz

Not applicable

11

C-11

1140 + 540 Hz

Not applicable

12

C-12

1020 + 540 Hz

Not applicable

13

C-13

900 + 540 Hz

Not applicable

14

C-14

780 + 540 Hz

Not applicable

15

C-15

660 + 540 Hz

Not applicable

Pulse Code Modulation Line Signaling

Table 2-6 describes the 2-bit, channel-associated pulse code modulation (PCM) line signaling used by the VCO system equipped with E1 interface cards. Forward signals are used by originating or outgoing ports, while backward signals are generated by incoming ports. For more information on E1 cards, refer to the Cisco VCO/4K Card Technical Descriptions.


Table 2-6: R2 Pulse Code Modulation Line Signaling
Number Signal Exchange Signaling Forward Backward
Af Bf Ab Bb

1

Idle

1 0

1 0

2

Seizure

0 0

1 0

3

Seizure acknowledge

0 0

1 0

6a

Clear forward before answer

1 0

1 1

Release guard

1 0

1 0

4

Seize acknowledge

0 0

1 1

4

Answer

0 0

0 1

6b

Clear forward after answer

1 0

0 1

7b

Release guard

1 0

1 0

5

Clear-back

0 0

1 1

6a

Clear forward after clear back

1 0

1 1

7

Release guard

1 0

1 0

8

Blocking

1 0

1 1

9

Unblocking

1 0

0 0


hometocprevnextglossaryfeedbacksearchhelp