Table 2-1 through Table 2-4 provide R2 signaling information based on ITU Q.441 as it applies specifically to the Mexico country feature package.


Table 2-1: R2 Signaling Group I Forward Signals
Token Data Field Designation Frequencies Meaning

1

G-I-1

1380 + 1500 Hz

Digit 1

2

G-I-2

1380 + 1620 Hz

Digit 2

3

G-I-3

1500 + 1620 Hz

Digit 3

4

G-I-4

1380 + 1740 Hz

Digit 4

5

G-I-5

1500 + 1740 Hz

Digit 5

6

G-I-6

1620 + 1740 Hz

Digit 6

7

G-I-7

1380 + 1860 Hz

Digit 7

8

G-I-8

1500 + 1860 Hz

Digit 8

9

G-I-9

1620 + 1860 Hz

a) Digit 9
b) Access to long distance system
c) Transit indication

10

G-I-10

1740 + 1860 Hz

a) Digit 0
b) Access to special service

11

G-I-11

1380 + 1980 Hz

Not applicable

12

G-I-12

1500 + 1980 Hz

Not applicable

13

G-I-13

1620 + 1980 Hz

Not applicable

14

G-I-14

1749 + 1980 Hz

Not applicable

15

G-I-15

1860 + 1980 Hz

Not applicable


Table 2-2: R2 Signaling Group II Forward Signals
Token Data Field Designation Frequencies Meaning

1

G-II-1

1380 + 1500 Hz

Not applicable

2

G-II-2

1380 + 1620 Hz

Ordinary subscriber without priority

3

G-II-3

1500 + 1620 Hz

Public phone

4

G-II-4

1380 + 1740 Hz

Time and cost

5

G-II-5

1500 + 1740 Hz

Not applicable

6

G-II-6

1620 + 1740 Hz

Not applicable

7

G-II-7

1380 + 1860 Hz

Long distance public phone

8

G-II-8

1500 + 1860 Hz

Not applicable

9

G-II-9

1620 + 1860 Hz

Not applicable

10

G-II-10

1740 + 1860 Hz

Not applicable

11

G-II-11

1380 + 1980 Hz

Not applicable

12

G-II-12

1500 + 1980 Hz

Not applicable

13

G-II-13

1620 + 1980 Hz

Not applicable

14

G-II-14

1740 + 1980 Hz

Not applicable

15

G-II-15

1860 + 1980 Hz

Not applicable


Table 2-3: R2 Signaling Group A Backward Signals
Token Data Field Designation Frequencies Meaning

1

A-1

1140 + 1020 Hz

Send next digit (n+1)

2

A-2

1140 + 900 Hz

Start from first digit

3

A-3

1020 + 900 Hz

Number complete; change over to reception of Group B signals

4

A-4

1140 + 780 Hz

Network congestion

5

A-5

1020 + 780 Hz

Not applicable

6

A-6

900 + 780 Hz

Send Group II signal and change to Group C signals

7

A-7

1140 + 660 Hz

Not applicable

8

A-8

1020 + 660 Hz

Not applicable

9

A-9

900 + 660 Hz

Not applicable

10

A-10

780 + 660 Hz

Not applicable

11

A-11

1140 + 540 Hz

Not applicable

12

A-12

1020 + 540 Hz

Not applicable

13

A-13

900 + 540 Hz

Not applicable

14

A-14

780 + 540 Hz

Not applicable

15

A-15

660 + 540 Hz

Not applicable


Table 2-4: R2 Signaling Group B Backward Signals
Token Data Field Designation Frequencies Meaning

1

B-1

1140 + 1020 Hz

Free with charging

2

B-2

1140 + 900 Hz

Busy

3

B-3

1020 + 900 Hz

Not applicable

4

B-4

1140 + 780 Hz

Blocking

5

B-5

1020 + 780 Hz

Free without charging

6

B-6

900 + 780 Hz

Not applicable

7

B-7

1140 + 660 Hz

Not applicable

8

B-8

1020 + 660 Hz

Not applicable

9

B-9

900 + 660 Hz

Not applicable

10

B-10

780 + 660 Hz

Not applicable

11

B-11

1140 + 540 Hz

Not applicable

12

B-12

1020 + 540 Hz

Not applicable

13

B-13

900 + 540 Hz

Not applicable

14

B-14

780 + 540 Hz

Not applicable

15

B-15

660 + 540 Hz

Not applicable


Table 2-5: R2 Signaling Group C Backward Signals
Token Data Field Designation Frequencies Meaning

1

C-1

1140 + 1020 Hz

Send next number of Subscriber A

2

C-2

1140 + 900 Hz

Send first digit BNUM

3

C-3

1020 + 900 Hz

Send Group II and Group B signals

4

C-4

1140 + 780 Hz

Congestion

5

C-5

1020 + 780 Hz

Send next digit BNUM

6

C-6

900 + 780 Hz

Repeat last digit BNUM

7

C-7

1140 + 660 Hz

Not applicable

8

C-8

1020 + 660 Hz

Not applicable

9

C-9

900 + 660 Hz

Not applicable

10

C-10

780 + 660 Hz

Not applicable

11

C-11

1140 + 540 Hz

Not applicable

12

C-12

1020 + 540 Hz

Not applicable

13

C-13

900 + 540 Hz

Not applicable

14

C-14

780 + 540 Hz

Not applicable

15

C-15

660 + 540 Hz

Not applicable

Pulse Code Modulation Line Signaling

Table 2-6 describes the 2-bit, channel-associated PCM line signaling used by VCO systems equipped with E1 interface cards. Forward signals are used by originating or outgoing ports, while backward signals are generated by incoming ports. For more information on E1 cards, refer to the Cisco VCO/4K Card Technical Descriptions.


Table 2-6: R2 Pulse Code Modulation Line Signaling
Signal Exchange Signaling
Forward Af Bf Backward Ab Bb

Idle

1 0

1 0

Seize

0 0

1 0

Seize acknowledge

0 0

1 1

Clear forward before answer

1 0

1 1

Release guard

1 0

1 0

Seizure acknowledge

0 0

1 1

Answer

0 0

0 1

Clear forward after answer

1 0

0 1

Release guard

1 0

1 0

Clear-back

0 0

1 1

Clear forward after clear-back

1 0

1 1

Release guard

1 0

1 0

Blocking

1 0

1 1

Unblocking

1 0

0 0