cc/td/doc/product/software/ssr921
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

SMDS Configuration Commands

SMDS Configuration Commands

Use the commands in this chapter to configure the Switched Multimegabit Data Service (SMDS), a wide-area networking service offered by some Regional Bell Operating Companies (RBOCs) and MCI.

For SMDS configuration information and examples, refer to the Communication Server Configuration Guide.

arp

Use the following variation of the arp interface configuration command to enable ARP entries for static routing over the SMDS network. Use the no arp command to disable this capability.

arp IP-address SMDS-address smds
no arp IP-address SMDS-address smds
Syntax Description
IP-address The IP address.
SMDS-address The SMDS address.
smds Enables ARP for SMDS.
Default

None

Command Mode

Interface configuration

Example

The following example sets a static ARP entry for routing from IP network 131.108.173.28 to SMDS address C141.5797.1313 on interface serial 0:

interface serial 0 arp 131.108.173.28 C141.5797.1313 smds
Related Command

smds enable-arp

encapsulation smds

Use the encapsulation smds interface configuration command to enable SMDS service on the desired interface.

encapsulation smds
Syntax Description

This command has no arguments or keywords.

Default

Disabled

Command Mode

Interface configuration

Usage Guidelines

The interface to which this command applies must be a serial interface. All subsequent SMDS configuration commands only apply to an interface with encapsulation SMDS.


Note  The maximum packet size allowed in the SMDS specifications (TA-772) is 9188. This is larger than the packet size used by servers with most media. The Cisco default MTU size is
1500 bytes, to be consistent with Ethernet. If a larger MTU is used, the mtu command must be entered before the encapsulation smds command.

Keep in mind, however, that the Cisco MCI card has buffer limitations that prevent setting the MTU size higher than 2048, and the HSSI card has buffer limitations that prevent setting the MTU size higher than 4500. Configuring higher settings has caused communication server inconsistencies and performance problems.
Example

The following example shows how to configure the SMDS service on serial interface 0:

interface serial 0 encapsulation smds
Related Command

A dagger (+) indicates that the command is documented in another chapter.

mtu+

show arp

Use the show arp EXEC command to display the entries in the ARP table for the communication server.

show arp
Syntax Description

This command has no arguments or keywords.

Command Mode

EXEC

Sample Display

The following is sample output from the show arp command:

cs# show arp Protocol    Address           Age (min)    Hardware Addr     Type    Interface

Table 1-1 describes significant fields shown in the display.


Show ARP Field Descriptions
Field Description
Protocol Type of network address the entry includes.
Address Network address that is mapped to the MAC address in this entry.
Age (min) Interval (in minutes) since this entry was entered in the table, rather than the interval since the entry was last used. (The timeout value is 4 hours.)
Hardware Addr MAC address mapped to the network address in this entry.
Type Encapsulation type the communication server is using for the network address in this entry. Possible values include:

  • ARPA

  • SNAP

  • ETLK (EtherTalk)

  • SMDS

Interface

Interface associated with this network address.

show smds addresses

Use the show smds addresses EXEC command to display the individual addresses and the interface that they are associated with.

show smds addresses
Syntax Description

This command has no arguments or keywords.

Command Mode

EXEC

Sample Display

The following is sample output from the show smds addresses command:

cs# show smds addresses SMDS address - Serial0 c141.5555.1212

Table 1-2 describes significant fields shown in the display.


Show SMDS Addresses Field Descriptions
Field Description
Serial0 Interface to which this SMDS address has been assigned.
c141.5555.1212 SMDS address that has been assigned to the interface.

show smds map

Use the show smds map EXEC command to display all SMDS addresses that are mapped to higher-level protocol addresses.

show smds map
Syntax Description

This command has no arguments or keywords.

Command Mode

EXEC

Sample Display

The following is sample output from the show smds map command:

cs# show smds map Serial0: ARP maps to e180.0999.9999 multicast Serial0: IP maps to e180.0999.9999 150.108.42.112 255.255.255.0 multicast Serial0: XNS 1006.AA00.0400.0C55 maps to c141.5688.1212 static [broadcast]

Table 1-3 describes significant fields shown in the output


Show SMDS Map Field Descriptions
Field Description
Serial0 Name of interface on which SMDS has been enabled.
ARP maps to Higher-level protocol address that maps to this particular SMDS address.
e180.0999.9999 SMDS address. Includes all SMDS addresses entered with either the smds static-map command (static) and smds multicast command (multicast).
150.108.21.112 IP address.
255.255.255.0 Subnet mask for the IP address.

Note Trailing Fs are implied in displays showing the SMDS addresses.

show smds traffic

Use the show smds traffic EXEC command to display statistics on bad SMDS packets the communication server has received.

show smds traffic
Syntax Description

This command has no arguments or keywords.

Command Mode

EXEC

Sample Display

The following is sample output from the show smds traffic command:

communication server# show smds traffic 624363 Input packets 759695 Output packets 2 DXI heartbeat sent 0 DXI heartbeat received 0 DXI DSU polls received 0 DXI DSU polls sent 0 DXI invalid test frames 0 Bad BA size errors 0 Bad Header extension errors 65 Invalid address errors 1 Bad tag errors

Table 1-4 describes significant fields shown in the output.


Show SMDS Traffic Field Descriptions
Field Description
0 Input packets Number of input packets.
0 Output packets Number of output packets.
0 DXI heartbeat sent Number of DXI heartbeat polls transmitted.
0 DXI heartbeat received Number of DXI heartbeat polls received.
0 DXI DSU polls sent Number of DXI DSU polls sent.
0 DXI DSU polls received Number of DXI DSU polls received.
0 DXI invalid test frames Number of invalid test frames seen.
0 Bad BA size errors Number of packets that have a size less than 32 bytes or greater than 9188 bytes.
0 Bad Header extension errors Number of extended SIP L3 header errors.
65 BadInvalid address errors Number of address errors
0 Bad tag errors Status indicating the number of errors that occur when there is a mismatch between the BeTag values in the header and trailer of a SMDS frame. This usually indicates that there is a misconfiguration (that is, a DXI is connected to a non-DXI) or that the SDSU is scrambling the L2 PDUs.

smds address

Use the smds address interface configuration command to specify the SMDS individual address for a particular interface. Use the no smds address command to remove the address from the configuration file.

smds address SMDS-address
no smds address
SMDS-address
Syntax Description
SMDS-address An individual address provided by the SMDS service provider. This address is protocol independent. See the "Usage Guidelines" section for more information.
Default

None

Command Mode

Interface configuration

Usage Guidelines

All addresses for SMDS service are assigned by the service provider, and can be assigned to individuals and groups.

A multicast address is entered in the Cisco SMDS configuration software using the standard E prefixes. The E1 prefix specifies North American addresses; the E0 prefix specifies European addresses. A unicast address is entered in the Cisco SMDS configuration software using the standard C prefixes. The C1 prefix specifies North American addresses; the C0 prefix specifies European addresses.

The Cisco software expects the addresses to be entered in a slightly modified E.164 format. E.164 format is 64 bits. The first 4 bits are type code followed by 4 bits of country code, followed by 10 BCD digits with the final 16 bits all ones. The full E.164 address is not required. The trailing FFFFs are not needed. They are not displayed and it is not necessary to type them when entering an address.

Example

The following example shows how to specify an individual address in Ethernet-style notation:

interface serial 0 smds address c141.5797.1313

smds dxi

Use the smds dxi interface configuration command to reenable the DXI 3.2 support. Use the no smds dxi command to turn the DXI 3.2 support off.

smds dxi
no smds dxi
Syntax Description

This command has no arguments or keywords.

Default

On

Command Mode

Interface configuration

Usage Guidelines

Adding this command to the configuration enables the Data Exchange Interface (DXI) Version 3.2 mechanism and encapsulates SMDS packets in a DXI frame before they are transmitted. DXI3.2 adds an additional four bytes to the SMDS packet header to communicate with the SDSU. These bytes specify the frame type. The interface will expect all packets to arrive with DXI encapsulation.

The DXI 3.2 support also includes the heartbeat process as specified in the SIG-TS-001/1991 standard, revision 3.2. The heartbeat (active process) is enabled when both DXI and keepalives are enabled on the interface. The echo (passive process) is enabled when DXI is enabled on the interface. The heartbeat mechanism automatically generates a heartbeat poll frame every
10 seconds. This default value can be changed with the keepalive command. The Interim Local Management Interface (ILMI) is not supported.


Note Switching in or out of DXI mode causes the IP cache to be cleared. This is necessary to remove all cached IP entries for the serial line being used. Stale entries must be removed to allow the new MAC header with or without DXI framing to be installed in the cache. This is not frequently done and is not considered to be a major performance penalty.
Example

The following example shows how to enable DXI 3.2 on interface HSSI 0:

interface hssi 0 encapsulation smds smds dxi-mode smds address C120.1111.2222 ip address 131.108.1.30 255.255.255.0 smds multicast ip E180.0999.9999 smds enable-arp
Related Command

A dagger (+) indicates that the command is documented in another chapter.

keepalive+

smds enable-arp

Use the smds enable-arp interface configuration command to enable the Address Resolution Protocol (ARP). The multicast address for ARP must be set before this command is issued. Once ARP has been enabled, use the no smds enable-arp command to return the interface to the default state.

smds enable-arp
no smds enable-arp
Syntax Description

This command has no arguments or keywords.

Default

Disabled

Command Mode

Interface configuration

Example

The following example illustrates how to enable the dynamic ARP routing table:

interface serial 0 ip address 131.108.1.30 255.255.255.0 smds multicast IP E180.0999.9999 smds enable-arp
Related Command

arp

smds multicast

Use the smds multicast interface configuration command to map an SMDS group address to a broadcast or multicast address used by higher-level protocols. Use the no smds multicast command with the appropriate address to remove a multicast address.

smds multicast protocol-type SMDS-address
no smds multicast
protocol-type SMDS-address
Syntax Description
protocol-type The protocol type; see Table 1-5 for a list of supported protocols and their keywords.
SMDS-address The SMDS address. Since SMDS does not incorporate broadcast addressing, a group address for a particular protocol must be defined to serve the broadcast function.

Supported Protocols
Keyword Protocol
ip IP
arp ARP
novell Novell IPX
Default

None

Command Mode

Interface configuration

Example

The following example shows how to map the IP broadcast address to the SMDS group address E180.0999.9999:

interface serial 0 smds multicast IP E180.0999.9999

smds multicast arp

Use the smds multicast arp interface configuration command to map the SMDS address to a multicast address. Use the no smds multicast arp command to disable this feature.

smds multicast arp SMDS-address [IP-address mask]
no smds multicast arp
SMDS-address [IP-address mask]
Syntax Description
SMDS-address SMDS address in E.164 format.
IP-address (Optional.) IP address.
mask (Optional.) Subnet mask for the IP address.
Default

None

Command Mode

Interface configuration

Usage Guidelines

This command is only used when an ARP server is present on a network. When broadcast ARPs are sent, SMDS first attempts to send the packet to all multicast ARP SMDS addresses. If none exist in the configuration, they are sent to all multicast IP SMDS multicast addresses. If the optional ARP multicast address is missing, each entered IP multicast command will be used for broadcasting.

Example

The following example illustrates how to configure broadcast ARP messages:

interface serial 0 smds multicast arp E180.0999.9999
Related Command

smds multicast ip

smds multicast ip

Use the smds multicast ip interface configuration command to map an SMDS group address to a secondary IP address. Use the no smds multicast ip command to remove the address map.

smds multicast ip SMDS-address [IP-address mask]
no smds multicast ip
SMDS-address [IP-address mask]
Syntax Description
SMDS-address SMDS address in E.164 format.
IP-address (Optional.) IP address.
mask (Optional.) Subnet mask for the IP address.
Default

The IP address and mask will default to the primary address of the interface if they are left out of the configuration.

Command Mode

Interface configuration

Usage Guidelines

This command allows a single SMDS interface to be treated as multiple logical IP subnets (MultiLIS). If taking advantage of the MultiLIS support in SMDS, you can use more than one multicast address on the SMDS interface, that is, multiple commands can be entered. However, each smds multicast ip command entry must be associated with a different IP address on the SMDS interface.

Broadcasts can be sent on the SMDS interface using the multicast address. By sending broadcasts in this manner, the communication server is not required or replicate broadcasts messages to every remote host.

In addition, the higher-level protocols such as OSPF can use the multicast capability by sending one update packet or routing packet to the multicast address.

If the optional IP address and mask arguments are not present, the SMDS address and multicast address are associated with the primary IP address of the interface. This allows the command to be backward compatible with earlier versions of the software.

If an ARP multicast address is missing, each entered IP multicast command will be used for broadcasting. The ARP multicast command has the same format as the IP multicast command and is typically used only when an ARP server is present in the network.


Note All communication servers at the other end of the SMDS cloud must have the MultiLIS capability enabled. A receiving communication server must have the primary IP network address of the transmitter configured as a secondary IP network. This is required in order for replies to return. IP discards all packets with a destination address not equal to the primary network address on the SMDS interface.
Example

The following example configures an interface that supports two different subnets with different multicast addresses to each network. The first multicast configuration command associates the multicast address with the primary IP address and mask of the interface.

interface hssi 0 encapsulation smds smds address C120.1111.2222 ip address 131.108.1.30 255.255.255.0 ip address 131.108.5.30 255.255.255.0 secondary smds multicast ip E180.0999.9999 smds multicast ip E180.0333.3333 131.108.5.0 255.255.255.0 smds enable-arp
Related Command

smds multicast arp

smds static-map

Use the smds static-map interface configuration command to configure a static map between an individual SMDS address and a higher-level protocol address. Use the no smds static-map command with the appropriate arguments to remove the map.

smds static-map protocol-type protocol-address SMDS-address [broadcast]
no smds static-map
protocol-type protocol-address SMDS-address [broadcast]
Syntax Description
protocol-type Supported protocol type: ip or novell.
protocol-address Address of the higher-level protocol.
SMDS-address SMDS address, to complete the mapping.
broadcast (Optional.) Marks the specified protocol address as a candidate for broadcast packets. All broadcast requests will be sent to the unicast SMDS address.
Default

None

Command Mode

Interface configuration

Usage Guidelines

This command provides pseudobroadcasting by allowing the use of broadcasts on those hosts that cannot support SMDS multicast addresses. Using pseudo-broadcasts can degrade performance.

Examples

The following example illustrates how to enable pseudobroadcasting. In addition to broadcasting IP and ARP requests to E180.0999.9999, the device at address C120.4444.9999 will also receive a copy of the broadcast request. The host at address 131.108.1.15 is incapable of receiving multicast packets. The multicasting is simulated with this feature.

interface hssi 0 encapsulation smds smds address C120.1111.2222 ip address 131.108.1.30 255.255.255.0 smds static-map ip 131.108.1.15 C120.4444.9999 broadcast smds enable-arp

The following example illustrates how to enable multicasting. In addition to IP and ARP requests to E180.0999.9999, the device at address C120.4444.9999 will also receive a copy of the multicast request. The host at address 131.108.1.15 is incapable of receiving broadcast packets.

interface hssi 0 encapsulation smds smds address C120.1111.2222 ip address 131.108.1.30 255.255.255.0 smds multicast ip E100.0999.999 smds static-map ip 131.108.1.15 C120.4444.9999 smds enable-arp

hometocprevnextglossaryfeedbacksearchhelp
Copyright 1989-1997 © Cisco Systems Inc.