cc/td/doc/product/software/ios122/122relnt
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table Of Contents

Release Notes for Cisco AS5800 Universal Access Servers for
Cisco IOS Release 12.2(2)XB15

Contents

Introduction

System Requirements

Memory Requirements

Supported Hardware

Determining the Software Version

Upgrading to a New Software Release

Microcode and Modem Code Software

Feature Set Tables

New and Changed Information

New Hardware and Software Features from Cisco IOS Release 12.2(2)XB2 to Cisco IOS Release 12.2(2)XB15

New Hardware Features in Cisco IOS Release 12.2(2)XB1

New Software Features in Cisco IOS Release 12.2(2)XB1

New Hardware and Software Features in Cisco IOS Release 12.2(2)XB

MIBs

Important Notes

Field Notices and Bulletins

Caveats for Cisco IOS Release 12.2 XB

Open Caveats—Cisco IOS Release 12.2(2)XB15

Resolved Caveats—Cisco IOS Release 12.2(2)XB15

Open Caveats—Cisco IOS Release 12.2(2)XB14

Resolved Caveats—Cisco IOS Release 12.2(2)XB14

No Caveats—Cisco IOS Release 12.2(2)XB13

Open Caveats—Cisco IOS Release 12.2(2)XB12

Resolved Caveats—Cisco IOS Release 12.2(2)XB12

Open Caveats—Cisco IOS Release 12.2(2)XB11

Resolved Caveats—Cisco IOS Release 12.2(2)XB11

Open Caveats—Cisco IOS Release 12.2(2)XB10

Resolved Caveats—Cisco IOS Release 12.2(2)XB10

Open Caveats—Cisco IOS Release 12.2(2)XB9

Resolved Caveats—Cisco IOS Release 12.2(2)XB9

Open Caveats—Cisco IOS Release 12.2(2)XB8

Resolved Caveats—Cisco IOS Release 12.2(2)XB8

Open Caveats—Cisco IOS Release 12.2(2)XB7

Resolved Caveats—Cisco IOS Release 12.2(2)XB7

Open Caveats—Cisco IOS Release 12.2(2)XB6

Resolved Caveats—Cisco IOS Release 12.2(2)XB6

Open Caveats—Cisco IOS Release 12.2(2)XB5

Resolved Caveats—Cisco IOS Release 12.2(2)XB5

Open Caveats—Cisco IOS Release 12.2(2)XB4

Resolved Caveats—Cisco IOS Release 12.2(2)XB4

Open Caveats—Cisco IOS Release 12.2(2)XB3

Resolved Caveats—Cisco IOS Release 12.2(2)XB3

Open Caveats—Cisco IOS Release 12.2(2)XB2

Resolved Caveats—Cisco IOS Release 12.2(2)XB2

Open Caveats—Cisco IOS Release 12.2(2)XB1

Resolved Caveats—Cisco IOS Release 12.2(2)XB1

Open and Resolved Caveats—Cisco IOS Release 12.2(2)XB

Related Documentation

Release-Specific Documents

Platform-Specific Documents

Feature Modules

Feature Navigator

Cisco IOS Software Documentation Set

Obtaining Documentation

World Wide Web

Documentation CD-ROM

Ordering Documentation

Documentation Feedback

Obtaining Technical Assistance

Cisco.com

Technical Assistance Center


Release Notes for Cisco AS5800 Universal Access Servers for
Cisco IOS Release 12.2(2)XB15


January 14, 2005

Cisco IOS Release 12.2(2)XB15

OL-1679-01 Rev. O2

These release notes for the Cisco AS5800 universal access servers describe the enhancements provided in Cisco IOS Release 12.2(2)XB15. These release notes are updated as needed.

For a list of the software caveats that apply to Cisco IOS Release 12.2(2)XB15, see the "Caveats for Cisco IOS Release 12.2 XB" section and Caveats for Cisco IOS Release 12.2. The caveats document is updated for every maintenance release and is located on Cisco.com and the Documentation CD-ROM.

Use these release notes with Cross-Platform Release Notes for Cisco IOS Release 12.2 located on Cisco.com and the Documentation CD-ROM.

Cisco recommends that you view the field notices for this release to see if your software or hardware platforms are affected. If you have an account on Cisco.com, you can find field notices at http://www.cisco.com/warp/customer/tech_tips/index/fn.html. If you do not have a Cisco.com login account, you can find field notices at http://www.cisco.com/warp/public/tech_tips/index/fn.html.

Contents

These release notes describe the following topics:

Introduction

System Requirements

New and Changed Information

MIBs

Caveats for Cisco IOS Release 12.2 XB

Related Documentation

Obtaining Documentation

Obtaining Technical Assistance

Introduction

The Cisco AS5800 universal gateway is a high-density, Integrated Services Digital Network (ISDN), and modem Wide Area Network (WAN) aggregation systems that provide digital and analog call termination. The Cisco AS5800 is intended to be used as a service provider dial point-of-presence (POP) or centralized enterprise dial gateway. The Cisco AS5800 consists of a dial shelf and one or two router shelves:

The Cisco DS5814 (dial shelf) has 14 slots and can support 1 or 2 dial shelf controller cards and up to 12 feature cards to provide full analog modem, and ISDN coverage. Analog calls are terminated by a feature card that is loaded with integrated modems.

ISDN calls are terminated onboard the trunk card on High-Level Data Link Control (HDLC) controllers. The E1, T1, and the CT3 trunk cards include channel service units (CSUs) and have either 12 E1 ports, 12 T1 ports, or 28 T1 ports (within the CT3 trunk) that can operate as Primary Rate Interfaces (PRIs), inter-machine trunks (IMTs), or channelized interfaces in any combination. The specific trunk card limitations are described in Table 2, Part 1.


Note T1 and E1 cards are not supported in the same box.


The Cisco RS7206VXR (router shelf) contains a network-processing engine, an I/O controller, and the egress interfaces, such as High-Speed Serial Interface (HSSI), Fast Ethernet (FE), Gigabit Ethernet (GE), and Asynchronous Transfer Mode (ATM), and supports either 280W AC-input or 280W DC-input redundant power. The router shelf also may contain one or two dial shelf interconnect port adapters each with a single RJ-45 receptacle, which is used to connect the router shelf to the Cisco 5814 dial shelf. The interconnect port adapter connects directly to the dial shelf controller card on the dial shelf via a Cisco-proprietary cable, customized with jack screws to secure the connection. You must use this specially designed cable that ships with your interconnect port adapter. Each router shelf can only be connected to one dial shelf controller card. If the dial shelf configured in split mode, it must be connected to two separate router shelves.


Note The router shelf is only supported for routing data to and from the dial shelf. The router should not be used with multiple port adapter interfaces to route LAN traffic between multiple networks.



Note Cisco IOS Release 12.2(2)XB1 does support the RS7206 router shelf.


The AC-input power shelf is an optional component of the Cisco AS5800 universal access servers and is used to convert AC-input power into DC-output power for the DC-powered Cisco 5814 dial shelf. The AC-input power shelf contains two AC-input power supplies.

The AC-input to DC-output connection supplies -48V DC-output power to the dial shelf power entry modules (PEMs). The PEMs receive the -48V and transmit power to the filter module. Power flows through the filter module to the backplane, where it is distributed to the dial shelf controller card and feature cards.

The AC-input power shelf includes two 2,000 W, AC-input power supplies that plug into a common power backplane in the AC-input power shelf. A single AC-input power supply is capable of powering a fully configured Cisco 5814 dial shelf. The second power supply provides full redundancy.

For information on new features and Cisco IOS commands supported by Cisco IOS Release 12.2(2)XB15, see the "New and Changed Information" section and the "Related Documentation" section.

System Requirements

This section describes the system requirements for Cisco IOS Release 12.2(2)XB15 and includes the following sections:

Memory Requirements

Supported Hardware

Determining the Software Version

Upgrading to a New Software Release

Microcode and Modem Code Software

Feature Set Tables

Memory Requirements

Table 1 Cisco AS5800 Universal Access Servers Memory Requirements

System Components
Feature Set
Image Name
Software Image
Flash
Memory
Required
DRAM
Memory
Required
Cisco AS5800

IP Standard

IP Plus

c5800-p4-mz

16 MB

256 MB

Dial Shelf: Cisco 5814

IP Plus

dsc-c5800-mz

8 MB

64 MB

Cisco AS5800

Service Provider Standard

Service Provider IPsec 56

c5800-k8p4-mz

16 MB

256 MB


Supported Hardware

Cisco IOS Release 12.2(2)XB15 supports the Cisco AS5800 universal gateway:

Cisco DS5814

Cisco RS7206 VXR

For detailed descriptions of the new hardware features, see the "New and Changed Information" section.

For additional information about supported hardware for this platform and release, please refer to the Hardware/Software Compatibility Matrix in the Cisco Software Advisor at the following location:

http://www.cisco.com/cgi-bin/front.x/Support/HWSWmatrix/hwswmatrix.cgi

Table 2, Part 1 Supported Hardware for the Cisco AS5800 Universal Access Servers 

Interfaces, Cards, Options, and Support
Description
Interfaces

12-port T1 or E1 termination card

1- port channelized T3 (CT3) termination card

Modem Cards

72-port modem card (HMM)1

144-port modem card (DMM)2

324-port modem card (UPC)

Dial Shelf

DS5814 Dial Shelf

Dial Shelf Controller (DSC) card

Voice Feature Cards (VFCs)3

96-port high complexity voice card (96VOX)

192-port high complexity voice card (192VOX)

192-port medium complexity voice card (192-MC-VOX)

336-port medium complexity voice card (336-MC-VOX)

Optional AC-input Power Shelves

Two AC-input power supplies

Router Shelf Support

RS7206VXR (NPE-300 based) Router Shelf

A single RS7206 VXR may be used to support up to 1344 modem sessions. Configurations above 1344 modem sessions require two RS7206VXR router shelves in split-shelf mode.

1 72-port modem card requires 32M DRAM.

2 144-port modem card requires 64M DRAM.

3 High-complexity voice cards (with codecs G.723.1, G.728, or G.729) require greater resources to perform complex coding and decoding that results in Voice-handling capacity reduction. Medium-complexity voice cards (with codecs G.711, G.726, or G.729a) can manage twice the number of Voice channels than high-complexity voice cards can.


Table 2, Part 2 Supported Hardware for the Cisco AS5800 Universal Access Servers 

Router Shelf
Port Adapter
Description
RS7206VXR Router Shelf

PA-100VG

Single Port 100VG Port Adapter

PA-12E/2FE

Dual-Wide Ethernet-Switch Port Adapter

PA-1C-E

1-Port ESCON Channel Port Adapter

PA-2E3

2-Port E3 Serial Port Adapter with E3 DSU

PA-2FEISL-FX

2-Port Fast Ethernet/ISL 100BaseTx Port Adapter

PA-2FEISL-TX

2-Port Fast Ethernet/ISL 100BaseFx Port Adapter

PA-2H

Port Adapter, 2-Port HSSI

PA-4B-U

4-Port BRI Port Adapter, U Interface

PA-4E

Port Adapter, 4-Port Ethernet,10BT

PA-4R-DTR

Port Adapter, 4-Port Token Ring (Hawkeye Based)

PA-4T+

Port Adapter, 4-Port Serial,5in1

RS7206VXR Router Shelf (continued)

PA-5EFL

Port Adapter, 5-Port Ethernet,10FL

PA-8B-S/T

8-Port BRI Port Adapter, S/T Interface

PA-8E

Port Adapter, 8-Port Ethernet,10BT

PA-8T-232

Port Adapter, 8-Port Serial,232

PA-8T-V35

Port Adapter, 8-Port Serial,V.35

PA-8T-X21

Port Adapter, 8-Port Serial,X.21

PA-A1-OC3MM

1-Port ATM OC3 Multi-Mode Port Adapter

PA-A1-OC3SM

1-Port ATM OC3 Single Mode Intermediate Reach Port Adapter

PA-A2-4E1XC-E3ATM

CES Port Adapter E3/E1 120 ohms

PA-A2-4E1XC-OC3SM

CES OC3 Port Adapter 4E1 Ports 120 ohms

PA-A2-4T1C-OC3SM

ATM CES Port Adapter, 4T1 CES Ports and 1 OC3 ATM SM Port

PA-A2-4T1C-T3ATM

ATM CES Port Adapter, 4T1 CES Ports and 1 T3 ATM Port

PA-A3-E3

1-Port ATM Enhanced E3 Port Adapter

PA-A3-OC3MM

1-Port ATM Enhanced OC3c/STM1 Multi-Mode

PA-A3-OC3SMI

1-Port ATM Enhanced OC3c/STM1 Single Mode

PA-A3-OC3SML

1-Port ATM Enhanced OC3c/STM1 Single Mode

PA-A3-T3

1-Port ATM Enhanced DS3 Port Adapter

PA-E3

1-Port E3 Serial Port Adapter with E3 DSU

PA-FE-FX

Port Adapter, 1-Port FE, 100FX

PA-FE-TX

Port Adapter, 1-Port FE,100TX

PA-GE

One-Port Gigabit Ethernet PA for 7200VXR

PA-H

Port Adapter, 1-Port HSSI

PA-MC-8E1/120

8-Port Multichannel E1 Port Adapter

PA-POS-OC3MM

1-Port Packet/SONET OC3c/STM1 Multi-Mode Port Adapter

PA-POS-OC3SMI

1-Port Packet/SONET OC3c/STM1 Single Mode (IR) Port Adapter

PA-POS-OC3SML

1-Port Packet/SONET OC3c/STM1 Single Mode (LR) Port Adapter

PA-T3

1-Port T3 Serial Port Adapter with T3 DSUs

PA-T3+

1-Port T3 Serial Port Adapter Enhanced


Determining the Software Version

To determine the version of Cisco IOS software running on your Cisco AS5800 universal access servers, log in to the Cisco AS5800 universal access servers and enter the show version EXEC command:

Router> show version
Cisco Internetwork Operating System Software
IOS (tm) 12.2 XB Software (c5800-p4-mz), Version 12.2(2)XB15, RELEASE SOFTWARE

Upgrading to a New Software Release

For general information about upgrading to a new software release, refer to Upgrading the Cisco IOS Software Release in Cisco Routers and Modems located at:

http://www.cisco.com/warp/public/130/upgrade_index.shtml

For specific information about upgrading Cisco IOS software, modem and firmware upgrades, and split dial shelf, refer to the "Provisioning" chapter in the Cisco AS5800 Operations, Administration, Maintenance, and Provisioning Guide (OAM&P) at:

http://www.cisco.com/univercd/cc/td/doc/product/access/acs_serv/as5800/sw_conf/58_oamp/index.htm

Microcode and Modem Code Software

Microcode software images are bundled with the system software image. Bundling eliminates the need to store separate microcode images. When the router starts, the system software unpacks the microcode software bundle and loads the proper software on all the interface processor boards.

You could have received a later version of modem code than the one bundled with the Cisco IOS software. The modem code in Flash memory is mapped to the modems. Unless you fully understand how Cisco IOS software uses modem code, it is important to keep the factory configuration.

To obtain the latest Cisco IOS software release compatible with Cisco MICA portware, refer to the Cisco AS5x00 MICA 6-Port and 12-Port Modem Module Portware/Cisco IOS Software Compatibility Matrixes at http://www.cisco.com/univercd/cc/td/doc/product/access/acs_serv/5300/sw_conf/sw_ports/compmat/mca12prt.htm.

The modem code release notes are on Cisco.com and the Documentation CD-ROM.

On Cisco.com at:

Technical Documents: Access Servers and Access Routers: Access Servers: Cisco AS5800: Configuration Documents for Cisco AS5800: Port Information

On the Documentation CD-ROM at:

Cisco Product Documentation: Access Servers and Access Routers: Access Servers: Cisco AS5800: Configuration Documents for Cisco AS5800: Port Information

Feature Set Tables

The Cisco IOS software is packaged in feature sets consisting of software images—depending on the platform. Each feature set contains a specific set of Cisco IOS features.

Cisco IOS Release 12.2(2)XB15 is based on the following releases:

Cisco IOS Release 12.1(5)XM

Cisco IOS Release 12.2(1)

All features in the above releases are in Cisco IOS Release 12.2(2)XB15. Their features are listed in the "Feature Set Tables" sections of the following release notes:

Release Notes for Cisco AS5800 universal access servers for Cisco IOS Release 12.1 XM at http://www.cisco.com/univercd/cc/td/doc/product/software/ios121/121relnt/5800/rn5800xm.htm

Cisco IOS Release 12.2 Cross-Platform Release Notes

Click Platform-Specific Information and Cisco AS5800 Universal Access Servers at http://www.cisco.com/univercd/cc/td/doc/product/software/ios122/122relnt/xprn122/index.htm


Caution Cisco IOS images with strong encryption (including, but not limited to, 168-bit Triple Data Encryption Standard [3DES] data encryption feature sets) are subject to United States government export controls and have limited distribution. Strong encryption images to be installed outside the United States are likely to require an export license. Customer orders may be denied or subject to delay because of United States government regulations. When applicable, purchaser and user must obtain local import and use authorizations for all encryption strengths. Please contact your sales representative or distributor for more information, or send an e-mail to export@cisco.com.

Table 3 lists the features and feature sets supported by the Cisco AS5800 universal access servers in Cisco IOS Release 12.2(2)XB15 and uses the following conventions:

Yes—The feature is supported in the software image.

No—The feature is not supported in the software image.

In—The number in the "In" column indicates the Cisco IOS release in which the feature was introduced.


Note These release notes are not cumulative and only list features that are new to Cisco IOS Release 12.2 XB. One of the parent releases for Cisco IOS Release12.2 XB is Cisco IOS Release 12.2(1). To find information about inherited features in this release, refer to Cisco.com or Feature Navigator. For Cisco.com, go to http://www.cisco.com/univercd/home/index.htm, select the appropriate software release under Cisco IOS Software, and click Release Notes. If you have a Cisco.com login account, you can use the Feature Navigator tool at http://www.cisco.com/go/f


Table 3 Feature List by Feature Set for the Cisco AS5800

Feature
In
Software Images by Feature Sets
 
IP Plus
Service Provider IPsec 56
Dial

V.44 LZJH Compression

12.2(2)XB1

Yes

Yes

V.92 Modem on Hold

12.2(2)XB1

Yes

Yes

V.92 Quick Connect

12.2(2)XB1

Yes

Yes

Multiservice Applications - Voice

Full Functionality Long Pound

12.2(2)XB1

Yes

Yes

RADIUS Packet of Disconnect

12.2(2)XB1

Yes

Yes

Other

Global Modem Counters

12.2(2)XB1

Yes

Yes


New and Changed Information

The following sections list the new hardware and software features supported by the Cisco AS5800 universal access servers for Cisco IOS Release 12.2(2)XB15.

New Hardware and Software Features from Cisco IOS Release 12.2(2)XB2 to Cisco IOS Release 12.2(2)XB15

No new hardware and software features are supported by the Cisco AS5800 universal access servers from Cisco IOS Release 12.2(2)XB2 to Cisco IOS Release 12.2(2)XB15.


Note Cisco IOS Release 12.2(2)XB9 is not distributed for widespread availability. Cisco IOS Release 12.2(2)XB13 does not exist.


New Hardware Features in Cisco IOS Release 12.2(2)XB1

No new hardware features are supported by the Cisco AS5800 universal access servers for Cisco IOS Release 12.2(2)XB1.

New Software Features in Cisco IOS Release 12.2(2)XB1

The following new software features are supported by the Cisco AS5800 universal access servers for Cisco IOS Release 12.2(2)XB1:

Full Functionality Long Pound

This feature allows an IVR application to detect a long pound (new call request) at any point after the gateway accepts the incoming call. When the calling-party presses "long #", the gateway terminates any current or pending call state and initiates a new call setup.

For further information, refer to the TCL IVR API Version 2.0 Programmer's Guide at http://www.cisco.com/univercd/cc/td/doc/product/access/acs_serv/vapp_dev/tclivrv2.htm.

Global Modem Counters

The Global Modem Counters feature adds two new global call counters for ISDN calls to the Cisco IOS software. For Cisco IOS Release 12.2(2)XB1, this feature is supported only on the Cisco AS5800 universal gateway. The CISCO-POP-MGMT-MIB has been updated with two new objects, cpmCallVolSuccISDNDigital and cpmCallVolAnalogCallClearedNormally. The cpmCallVolSuccISDNDigital object allows the Cisco IOS software to track the number of successful incoming and outgoing ISDN digital data calls that have occurred since the system was started. The cpmCallVolAnalogCallClearedNormally object allows the Cisco IOS to track the number of successful incoming and outgoing analog data calls.

No new commands have been introduced with this feature. To use this feature, enable System Network Management Protocol (SNMP) and the corresponding OIDs for these new objects. To obtain lists of supported MIBs by platform and Cisco IOS release, and to download MIB modules, go to the Cisco MIB website on Cisco.com at the following URL:

http://www.cisco.com/public/sw-center/netmgmt/cmtk/mibs.shtml

RADIUS Packet of Disconnect

This feature consists of a method for terminating a call that has already been connected. This "Packet of Disconnect" (POD) is a RADIUS access_reject packet and is intended to be used in situations where the AAA server wants to disconnect the user after the session has been accepted by the RADIUS access_accept packet. This may be needed in at least two situations:

Detection of fraudulent use, which cannot be performed before accepting the call.

A price structure so complex that the maximum session duration cannot be estimated before accepting the call. This may be the case when certain types of discounts are applied or when multiple users use the same subscription simultaneously.

Refer to the following document for further information:

http://www.cisco.com/univercd/cc/td/doc/product/software/ios122/122newft/122limit/122x/122xb/122xb_2/ft_pod.htm

V.44 LZJH Compression

V.44 LZJH is a new compression standard based on Lempel-Ziv that uses a new string-matching algorithm that increases upload and download speeds to make Internet access and Web browsing faster. The V.44 call success rate (CSR) is similar to V.42bis with significant compression improvement for most file types, including HTML files. V.44 applies more millions of instructions per second (MIPS) than V.42bis toward the same application data stream and yields better compression rates in almost any data stream in which V.42bis shows positive results.

V.44 supports automatic switching between compressed and transparent modes on NextPort DFC-108NP-bearing platforms. Automatic switching allows overall performance gain without loss in throughput for file streams that are not compressible.

V.44 is globally controlled through dialed number ID service (DNIS), calling line ID (CLID), and resource pool manager server (RPMS) virtual groups, and performance improvement is determined by the LZJH algorithms. The NextPort Dial Feature Card (DFC) is responsible for the ITU implementation of V.44 and the collection of statistics related to the new feature.

To support V.44 LZJH compression, the control switch module (CSM) has been modified. MIBs that show the status of V.42bis have been extended to show V.44 configuration status. New disconnect reasons help manage V.44 session status and debugging.

For further details, please see http://www.cisco.com/univercd/cc/td/doc/product/software/ios122/122newft/122limit/122x/122xb/122xb_2/ft_v44.htm.

V.92 Modem on Hold

V.92 Modem on Hold allows a dial-in customer to suspend a modem session to answer an incoming voice call or to place an outgoing call while engaged in a modem session. When the dial-in customer uses Modem on Hold to suspend an active modem session to engage in an incoming voice call, the Internet service provider (ISP) modem listens to the original modem connection and waits for the dial-in customer's modem to resume the connection. When the voice call ends, the modem signals the telephone system to end the second call and return to the original modem connection, then the modem signals the ISP modem that it is ready to resume the modem call. Both modems renegotiate the connection, and the original exchange of data continues.


Note This feature is designed for use on telephone lines that are configured for call-waiting service; call-waiting signals trigger the suspension of the modem session. If call-waiting service is not present on the subscriber's line, other callers receive a busy signal, and the modem session is not interrupted.


For further details, please see http://www.cisco.com/univercd/cc/td/doc/product/software/ios122/122newft/122limit/122x/122xb/122xb_2/ftv92moh.htm.

V.92 Quick Connect

V.92 Quick Connect speeds up the client-to-server startup negotiation, reducing the overall connect time up to 30 percent. The client modem retains line condition information and characteristics of the connection to the Internet service provider (ISP), which reduces connect time by avoiding some of the initial signal handshaking.

For further details, please see:
http://www.cisco.com/univercd/cc/td/doc/product/software/ios122/122newft/122limit/122x/122xb/122xb_2/ftv92qc.htm.

New Hardware and Software Features in Cisco IOS Release 12.2(2)XB

Cisco IOS Release 12.2(2)XB does not support the Cisco AS5800 universal access servers.

MIBs

To locate and download MIBs for selected platforms, Cisco IOS releases, and feature sets, use Cisco MIB Locator found at the following URL:

http://tools.cisco.com/ITDIT/MIBS/servlet/index

If Cisco MIB Locator does not support the MIB information that you need, you can also obtain a list of supported MIBs and download MIBs from the Cisco MIBs page at the following URL:

http://www.cisco.com/public/sw-center/netmgmt/cmtk/mibs.shtml

To access Cisco MIB Locator, you must have an account on Cisco.com. If you have forgotten or lost your account information, send a blank e-mail to cco-locksmith@cisco.com. An automatic check will verify that your e-mail address is registered with Cisco.com. If the check is successful, account details with a new random password will be e-mailed to you. Qualified users can establish an account on Cisco.com by following the directions found at this URL:

http://www.cisco.com/register

The Cisco AS5800 universal access servers supports the following MIBs:

ATM-MIB

CALL TRACKER MIB

CISCO MEMORY POOL MIB

CISCO TOKEN RING MIB

CISCO-ATM2-MIB

CISCO-ATM-IF-PHYS-MIB

CISCO-ATM-SIG-DIAG-MIB

CISCO-BULK-FILE-MIB

CISCO-CALL-HISTORY-MIB

CISCO-ENTITY-MIB

CISCO-FRAME-RELAY-MIB

CISCO-ISDN-MIB

CISCO-POP-MGMT-MIB

CISCO-SYSLOG-MIB

CISCO-VPDN-MGMT-MIB

EXPRESSION-MIB

FDDI-SMT73-MIB

FSIP MIB

OLD-CISCO-CHASSIS-MIB

OLD-CISCO-MEMORY-MIB

PROCESS MIB

RFC1398-MIB

RTT Mon MIB

SONET-MIB

Important Notes

The following sections contain important notes about Cisco IOS Release 12.2 XB that can apply to the Cisco AS5800 universal access servers.

Field Notices and Bulletins

For general information about the types of documents listed in this section, refer to the following document:

http://www.cisco.com/warp/customer/cc/general/bulletin/software/general/1654_pp.htm

Field Notices—Cisco recommends that you view the field notices for this release to see if your software or hardware platforms are affected. If you have an account on Cisco.com, you can find field notices at http://www.cisco.com/warp/customer/tech_tips/index/fn.html. If you do not have a Cisco.com login account, you can find field notices at http://www.cisco.com/warp/public/tech_tips/index/fn.html.

Product Bulletins—If you have an account on Cisco.com, you can find product bulletins at http://www.cisco.com/warp/customer/cc/general/bulletin/index.shtml. If you do not have a Cisco.com login account, you can find product bulletins at http://www.cisco.com/warp/public/cc/general/bulletin/iosw/index.shtml.

What's New for IOS — What's New for IOS lists recently posted Cisco IOS software releases and software releases that have been removed from Cisco.com. If you have an account with Cisco.com you can access What's New for IOS at http://www.cisco.com/kobayashi/sw-center/sw-ios.shtml or by logging in and selecting Software Center: Cisco IOS Software.

Caveats for Cisco IOS Release 12.2 XB

Caveats describe unexpected behavior in Cisco IOS software releases. Severity 1 caveats are the most serious caveats; severity 2 caveats are less serious. Severity 3 caveats are moderate caveats, and only select severity 3 caveats are included in the caveats document.

This section contains only open and resolved caveats for the current Cisco IOS maintenance release.

All caveats in Cisco IOS Release 12.1(5)XM and Cisco IOS Release 12.2(1) are also in Cisco IOS Release 12.2(2)XB15.

For information on caveats in Cisco IOS Release 12.1(5)XM see the "Caveats" section in the Release Notes for Cisco AS5400 Universal Gateways for Cisco IOS Release 12.1 XM at http://www.cisco.com/univercd/cc/td/doc/product/software/ios121/121relnt/5800/rn5800xm.htm.

For information on caveats in Cisco IOS Release 12.2(1), see Caveats for Cisco IOS Release 12.2, which lists severity 1 and 2 caveats and select severity 3 caveats and is located on Cisco.com and the Documentation CD-ROM.


Note If you have an account with Cisco.com, you can also use the Bug Toolkit to find select caveats of any severity. To reach the Bug Toolkit, log in to Cisco.com and click Service & Support: Software Center: Cisco IOS Software: BUG TOOLKIT. Another option is to go to http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl.


Open Caveats—Cisco IOS Release 12.2(2)XB15

There are no open caveats specific to Cisco IOS Release 12.2(2)XB15 that require documentation in the release notes.

Resolved Caveats—Cisco IOS Release 12.2(2)XB15

All the caveats listed in this section are resolved in Cisco IOS Release 12.2(2)XB15. This section describes only severity 1 and 2 caveats and select severity 3 caveats.

Table 4 Resolved Caveats for Cisco IOS Release 12.2(2)XB15 

DDTS ID Number
Description

CSCec87533

ios fw hang then crash with h323 corrupt packet

Cisco products running IOS contain vulnerabilities in the processing of H.323 messages, which are typically used in packetized voice or multimedia applications. Features such as NAT and IOS Firewall must inspect H.323 messages and may be vulnerable as well. A test suite has been developed by the University of Oulu to target this protocol and identify vulnerabilities.

Support for the H.323 protocol was introduced in Cisco IOS Software Release 11.3T, and all later Cisco IOS releases are affected if configured for various types of Voice/Multimedia Application support. The vulnerabilities can be exploited repeatedly to produce a denial of service (DoS).

There are workarounds available that may mitigate the impact, but these techniques may not be appropriate for use in all customer networks.

This advisory is available at http://www.cisco.com/warp/public/707/cisco-sa-20040113-h323.shtml.


Open Caveats—Cisco IOS Release 12.2(2)XB14

There are no open caveats specific to Cisco IOS Release 12.2(2)XB14 that require documentation in the release notes.

Resolved Caveats—Cisco IOS Release 12.2(2)XB14

All the caveats listed in this section are resolved in Cisco IOS Release 12.2(2)XB14. This section describes only severity 1 and 2 caveats and select severity 3 caveats.

Table 5 Resolved Caveats for Cisco IOS Release 12.2(2)XB14 

DDTS ID Number
Description

CSCdx76632

as5300 crashed in MultiBitDecode

Cisco products running IOS contain vulnerabilities in the processing of H.323 messages, which are typically used in packetized voice or multimedia applications. Features such as NAT and IOS Firewall must inspect H.323 messages and may be vulnerable as well. A test suite has been developed by the University of Oulu to target this protocol and identify vulnerabilities.

Support for the H.323 protocol was introduced in Cisco IOS Software Release 11.3T, and all later Cisco IOS releases are affected if configured for various types of Voice/Multimedia Application support. The vulnerabilities can be exploited repeatedly to produce a denial of service (DoS).

There are workarounds available that may mitigate the impact, but these techniques may not be appropriate for use in all customer networks.

This advisory is available at http://www.cisco.com/warp/public/707/cisco-sa-20040113-h323.shtml.

CSCea19885

Bus error at address 0xD0D0D0B, Process CCH323_CT

Symptoms: A Cisco router that has a voice feature such as H.323 enabled may reload because of a bus error at address 0xD0D0D0B.

Conditions: This symptom is observed on a Cisco 3700 series but may also occur on other routers.

Workaround: There is no workaround.

CSCea27536

Router crash when H323v3/v4 pkts pass through NAT router

Cisco products running IOS contain vulnerabilities in the processing of H.323 messages, which are typically used in packetized voice or multimedia applications. Features such as NAT and IOS Firewall must inspect H.323 messages and may be vulnerable as well. A test suite has been developed by the University of Oulu to target this protocol and identify vulnerabilities.

Support for the H.323 protocol was introduced in Cisco IOS Software Release 11.3T, and all later Cisco IOS releases are affected if configured for various types of Voice/Multimedia Application support. The vulnerabilities can be exploited repeatedly to produce a denial of service (DoS).

There are workarounds available that may mitigate the impact, but these techniques may not be appropriate for use in all customer networks.

This advisory is available at http://www.cisco.com/warp/public/707/cisco-sa-20040113-h323.shtml.

NAT router (which is H323v2 stack aware) crashes when H323v3/v4 pkt is processed as "ip nat service h323all" is turned on.

Workaround: Turn off "ip nat service h323all" or move to 12.3T image (which has NAT-H323v3/v4) support

CSCea32240

H323 crashes in strncpy when receiving invalid setup packet

Cisco products running IOS contain vulnerabilities in the processing of H.323 messages, which are typically used in packetized voice or multimedia applications. Features such as NAT and IOS Firewall must inspect H.323 messages and may be vulnerable as well. A test suite has been developed by the University of Oulu to target this protocol and identify vulnerabilities.

Support for the H.323 protocol was introduced in Cisco IOS Software Release 11.3T, and all later Cisco IOS releases are affected if configured for various types of Voice/Multimedia Application support. The vulnerabilities can be exploited repeatedly to produce a denial of service (DoS).

There are workarounds available that may mitigate the impact, but these techniques may not be appropriate for use in all customer networks.

This advisory is available at http://www.cisco.com/warp/public/707/cisco-sa-20040113-h323.shtml.

CSCea33065

H323 Spurious memory access in h450ProcRcvdApdus

Cisco products running IOS contain vulnerabilities in the processing of H.323 messages, which are typically used in packetized voice or multimedia applications. Features such as NAT and IOS Firewall must inspect H.323 messages and may be vulnerable as well. A test suite has been developed by the University of Oulu to target this protocol and identify vulnerabilities.

Support for the H.323 protocol was introduced in Cisco IOS Software Release 11.3T, and all later Cisco IOS releases are affected if configured for various types of Voice/Multimedia Application support. The vulnerabilities can be exploited repeatedly to produce a denial of service (DoS).

There are workarounds available that may mitigate the impact, but these techniques may not be appropriate for use in all customer networks.

This advisory is available at http://www.cisco.com/warp/public/707/cisco-sa-20040113-h323.shtml.

CSCea36231

Router hangs when receive in invalid h225 setup

Cisco products running IOS contain vulnerabilities in the processing of H.323 messages, which are typically used in packetized voice or multimedia applications. Features such as NAT and IOS Firewall must inspect H.323 messages and may be vulnerable as well. A test suite has been developed by the University of Oulu to target this protocol and identify vulnerabilities.

Support for the H.323 protocol was introduced in Cisco IOS Software Release 11.3T, and all later Cisco IOS releases are affected if configured for various types of Voice/Multimedia Application support. The vulnerabilities can be exploited repeatedly to produce a denial of service (DoS).

There are workarounds available that may mitigate the impact, but these techniques may not be appropriate for use in all customer networks.

This advisory is available at http://www.cisco.com/warp/public/707/cisco-sa-20040113-h323.shtml.

CSCea46342

h.323 crashes in ACFnonStandardInfo DEC_ERR=13

Cisco products running IOS contain vulnerabilities in the processing of H.323 messages, which are typically used in packetized voice or multimedia applications. Features such as NAT and IOS Firewall must inspect H.323 messages and may be vulnerable as well. A test suite has been developed by the University of Oulu to target this protocol and identify vulnerabilities.

Support for the H.323 protocol was introduced in Cisco IOS Software Release 11.3T, and all later Cisco IOS releases are affected if configured for various types of Voice/Multimedia Application support. The vulnerabilities can be exploited repeatedly to produce a denial of service (DoS).

There are workarounds available that may mitigate the impact, but these techniques may not be appropriate for use in all customer networks.

This advisory is available at http://www.cisco.com/warp/public/707/cisco-sa-20040113-h323.shtml.

CSCea51030

h323: proxy crashes when malformed h225 setup message received

Cisco products running IOS contain vulnerabilities in the processing of H.323 messages, which are typically used in packetized voice or multimedia applications. Features such as NAT and IOS Firewall must inspect H.323 messages and may be vulnerable as well. A test suite has been developed by the University of Oulu to target this protocol and identify vulnerabilities.

Support for the H.323 protocol was introduced in Cisco IOS Software Release 11.3T, and all later Cisco IOS releases are affected if configured for various types of Voice/Multimedia Application support. The vulnerabilities can be exploited repeatedly to produce a denial of service (DoS).

There are workarounds available that may mitigate the impact, but these techniques may not be appropriate for use in all customer networks.

This advisory is available at http://www.cisco.com/warp/public/707/cisco-sa-20040113-h323.shtml.

CSCea51076

h323: proxy crashes when processing invalid h225 setup messafe

Cisco products running IOS contain vulnerabilities in the processing of H.323 messages, which are typically used in packetized voice or multimedia applications. Features such as NAT and IOS Firewall must inspect H.323 messages and may be vulnerable as well. A test suite has been developed by the University of Oulu to target this protocol and identify vulnerabilities.

Support for the H.323 protocol was introduced in Cisco IOS Software Release 11.3T, and all later Cisco IOS releases are affected if configured for various types of Voice/Multimedia Application support. The vulnerabilities can be exploited repeatedly to produce a denial of service (DoS).

There are workarounds available that may mitigate the impact, but these techniques may not be appropriate for use in all customer networks.

This advisory is available at http://www.cisco.com/warp/public/707/cisco-sa-20040113-h323.shtml.

CSCea54851

h323 proxy: crash at pxy_proc_recv_SETUP when invalid h225 setup rx

Cisco products running IOS contain vulnerabilities in the processing of H.323 messages, which are typically used in packetized voice or multimedia applications. Features such as NAT and IOS Firewall must inspect H.323 messages and may be vulnerable as well. A test suite has been developed by the University of Oulu to target this protocol and identify vulnerabilities.

Support for the H.323 protocol was introduced in Cisco IOS Software Release 11.3T, and all later Cisco IOS releases are affected if configured for various types of Voice/Multimedia Application support. The vulnerabilities can be exploited repeatedly to produce a denial of service (DoS).

There are workarounds available that may mitigate the impact, but these techniques may not be appropriate for use in all customer networks.

This advisory is available at http://www.cisco.com/warp/public/707/cisco-sa-20040113-h323.shtml.

CSCeb78836

h323: software forced crash if bad packet received and debug opened

Symptoms: Cisco IOS software may cause a Cisco router to reload unexpectedly when the router receives a malformed H.225 setup message.

Conditions: This symptom is observed on a Cisco 1700 series that runs Cisco IOS Release 12.2(13c). The symptom occurs when the following debug privileged EXEC commands are enabled:

debug h225 asn1

debug h225 events

debug h225 q931

Workaround: There is no workaround.


No Caveats—Cisco IOS Release 12.2(2)XB13

Cisco IOS Release 12.2(2)XB13 does not exist so no caveats are documented.

Open Caveats—Cisco IOS Release 12.2(2)XB12

There are no open caveats specific to Cisco IOS Release 12.2(2)XB12 that require documentation in the release notes.

Resolved Caveats—Cisco IOS Release 12.2(2)XB12

All the caveats listed in this section are resolved in Cisco IOS Release 12.2(2)XB12. This section describes only severity 1 and 2 caveats and select severity 3 caveats.

Table 6 Resolved Caveats for Cisco IOS Release 12.2(2)XB12

DDTS ID Number
Description

CSCdp42990

Modem log shows false outgoing calls

Symptom: On rare occasions, a Cisco AS5300 or Cisco AS5800 access server, with MICA modems, is seen to place spurious outbound calls, even if configured not to allow such calls. These calls fail to train up; an examination of the modem log shows them to be placed to garbage hexadecimal addresses.

Sometimes these spurious outbound calls are placed while in the middle of an active modem session, often shortly following a speedshift. Any active call is terminated shortly following the dialout attempt.

Here are some examples of such calls, as seen in the modem log:


02:59:57: ISDN outgoing called number: ADAADBADAC

08:43:32: ISDN outgoing called number: DBDD2D

01:28:33: ISDN outgoing called number: AAC102A

Workaround: If using an image with the CSCdw44612 fix (12.2(7.6+)*), and if there is no need to allow outbound calls, then configure modem dialin on the modem lines. This does not prevent the spurious outbound call events from hanging up the calls active on the affected lines, but does prevent an outbound call attempt from being signaled to the circuit network.

CSCdu53400

Incorrect count in sh call calltracker summ after digital call down

Symptom: In the Cisco AS5800 access server environment with SS7 setup, the show call calltracker summary command is not showing the correct number of calls for MLPPP digital calls after the calls are being torn down. This occurs due to the sh call calltracker active still displaying some digital calls that have already been torn down.

Async modem calls are working properly.

Workaround: There is no workaround.

CSCdz80238

Modems suddenly download portware...portware download fails

Symptom: MICA portware download fails on Cisco AS5300. Modems are marked bad.

Conditions: The trigger for this issue is not yet known.

Workaround: There is no workaround.

CSCea02945

Memory leak in AAA Attr List when EXEC author uses local RADIUS

Symptom: A Cisco router may experience a memory leak if the AAA EXEC authorization method list is configured to use local then RADIUS.

Workaround: Disable EXEC authorization or use RADIUS then local.

CSCea11487

Framed-callback with user defined callback number fails

Symptom: When using Framed-callback and the callback number needs to be specified by user input, you get the next message:

*Feb 6 09:55:16: Se7/1:0 MCB: Callback not authorized for this user ww

The excepted behavior is that the NAS should proceed with Microsoft Callback and callback to user. However, the NAS negotiates Callback 'None'.

Feb 6 09:55:12: Se7/1:0 MCB: O Request Id 19 Callback Type None

This behavior is incorrect.

Workaround: Using Callback with Cisco-AV-pair and the empty dialstring option.

Configuring MS Callback Between a Router and a Windows PC

http://www.cisco.com/en/US/tech/tk801/tk36/technologies_configuration_example09186a0080094338.shtml

Configuring PPP Callback with RADIUS

http://www.cisco.com/en/US/products/sw/secursw/ps2086/products_configuration_example09186a0080093dc9 .shtml#output2

Configuring PPP Callback over ISDN with an AAA Provided Callback String

http://www.cisco.com/en/US/tech/tk713/tk507/technologies_configuration_example09186a00800946ff.shtml

CSCea20210

sh controller E1 does not show the line status of DSOs (ABCD values)

Symptom: Command show controller E1 does not display the line status of DSOs (ABCD values) on a Cisco Access Server AS5850 running Cisco IOS Release 12.2(2)XB10 and Release 12.2(13)T.

This is an issue with only the show command, and it does not effect any real-time performance nor hamper any call treatment. It just hampers an effective way to troubleshoot the line.

Workaround: There is no workaround.

CSCea69547

Busied Out Modem counters not increasing upon firmware download

Symptom: On a Cisco AS5300 access router the busyout couner may not be incremented per port when the module is recovered through maintenance action.

Workaround: There is no workaround.

CSCea75851

Attribute 195 reported as No Reason

Symptom: Attribute 195 may report No Reason cause on Cisco AS5800 access server running Cisco IOS Release 12.2(2)XB10.

Workaround: There is no workaround.

CSCea77220

Extra accounting STOP record generated if guard timer enable

Symptom: An unexpected resource accounting stop record is being sent after the ISDN guard timer expires.

Conditions: This occurs under some very specific conditions, namely:

1. ISDN guard timer is configured to accept on expiry;

2. Stop-failure resource accounting is configured; and

3. Pre-authentication is held up (e.g. due to the unavailability of the AAA server).

Workaround: Configure the aaa session-id unique command.

CSCea79607

First Outgoing CONFREQ not received by Windows PPP clients

Symptom: First outgoing CONFREQ is not recieved by the PPP Windows DUN client.

Conditions: LCP negotiation takes a longer time.

Workaround: Make all connections into the NAS dedicated by configuring the async mode dedicated command under the Group-Async interface.

CSCeb01518

Line crash at ds_m32x_bground_daemon

Symptom: Board may crash on AS5800 running 12.2(8)XB6.D3 with following:

28w2d: %SYS-3-CPUHOG: Task ran for 2384 msec (331/215), process = DS M32x Background Daemon, PC = 601D9038.

-Traceback= 601D9040 60111EEC 60111ED8

Workaround: There is no workaround.

CSCeb08802

DS0 info of CAS T1s not reported in RADIUS accounting

Symptom: RADIUS accounting for CAS T1s may not report on the DS0 information.

Conditions: This occurs on a Cisco AS5400 with CAS T1s provisioned.

Workaround: There is no workaround.


Open Caveats—Cisco IOS Release 12.2(2)XB11

This section documents possible unexpected behavior by Cisco IOS Release 12.2(2)XB11 and describes only severity 1 and 2 caveats and select severity 3 caveats.

Table 7 Open Caveats for Cisco IOS Release 12.2(2)XB11 

DDTS ID Number
Description

CSCea27180

Symptom: Cisco AS5800 running Cisco IOS Release 12.2(XB)10 may reload with following error.

Feb 9 10:32:58.635: %SYS-3-OVERRUN: Block overrun at 203A4358 (red zone 00080000)
-Traceback= 60580B48 60583B80 60585D78 60585FE8 6057414C 60574138

This happens due to memory corruption.

Conditions: None found.

Workaround: There is no workaround.

More details: Customer is suggested to configure "debug sanity" and commands to write core files when system reloads due to unexpected events.

CSCea75851

Attribute 195 may report No Reason cause on Cisco AS 5800 running 12.2(2)XB10.

Symptom: Attribute 195 may report No Reason cause on a Cisco AS 5800 that is running Cisco IOS Release 12.2(2)XB10.

Workaround: There is no workaround.

CSCea83232

Modems failing to negotiate data compression fail in autoselect

Symptom: On a Cisco Systems AS5xxx access server running NextPort technology, some modem connections may exhibit failures where EC/DC negotiation fails.

Workaround: There is no workaround.


Resolved Caveats—Cisco IOS Release 12.2(2)XB11

All the caveats listed in this section are resolved in Cisco IOS Release 12.2(2)XB11. This section describes only severity 1 and 2 caveats and select severity 3 caveats.

Table 8 Resolved Caveats for Cisco IOS Release 12.2(2)XB11

DDTS ID Number
Description

CSCdr31105

Need to differentiate modem states of shut and busyout

Symptom: A modem placed in shutdown state shows up in show modem as a busy out modem whereas its in the shutdown state.

Conditions: Issuing a shutdown under the modem and then following it up with a show modem will exhibhit the problem.

Workaround: Issuing the command show line <nn> will show the modem in shutdown state. This issue is now resolved.

CSCdt58342

Excessive FIRMWARE_RUNNING/FIRMWARE_STOPPED messages

Symptom: On a Cisco AS5300 with a "+" E1/T1 trunk card, the console may display the following error messages:


Feb 28 06:54:37 %DSX1-1-FIRMWARE_STOPPED: T1/E1 Firmware is not running
Feb 28 06:54:38 %DSX1-1-FIRMWARE_RUNNING: T1/E1 Firmware is running

The FIRMWARE_RUNNING message appears a few seconds after the FIRMWARE_STOPPED message. This may recur irregularly at intervals of several minutes or hours. These messages are believed to be cosmetic only and not service impacting.

Workaround: There is no workaround.

CSCdu15973

ISDN should reject V110 calls based on LLC octet 5a

Symptom: When a router receives a V.110 call with User rate = 0, even the call is an asynchronous call and not in-band negotiable, ISDN still passes the call to the application.

Conditions: V.110 call, User Rate = 0, Async call AND NOT in-band negotiable

Workaround: There is no workaround.

CSCdu47222

Modem status messages passed to EXEC process

Symptom: When a user logs in to a Cisco 3620 router by using an external modem, the RING and CONNECT status messages pass to the EXEC process. An unknown command error results when the status messages that are passed to the EXEC process are interpreted as commands.

Workaround: There is no workaround.

CSCdu58902

GW piggybacks when piggybacking turned off

Conditions: This problem can occur when Media Gateway Contol Protocol (MGCP ) piggybacking is turned off and when the gateway is attempting to send an command at the same time as it is sending an acknowlegement to a CA initiated command.

Symptom: The Ack is piggybacked to the command.

Workaround: There is no workaround.

CSCdu80540

System crashes when user tries to delete file with ciscoFlashMiscOpT

Symptom: When a user tries to delete a file using ciscoFlashMiscOpTable with ciscoFlashMiscOpDestinationName set to a string that is greater than 33 characters, the system may crash. This caveat has been fixed in Cisco IOS Release 12.1(8)ES and later releases.

Workaround: There is no workaround.

CSCdv29225

5300 returns channel state to IDLE after receiving GSM OOS from SC

Symptom: On a Cisco AS5300 universal access server that is running Cisco IOS Release 12.2(2)XA1 in a Signaling System 7 (SS7) Interconnect for Voice Gateway solution, if a call is made ingress to the solution from a Public Switched Telephone Network (PSTN) and if a requested continuity test (COT) fails, the Cisco SC2200 signaling controller will send a group service message to the Cisco AS5300 and puts the associated channel on the access server into the maintenance state. However, the Cisco AS5300 puts the associated channel into the idle state a few seconds later. This behavior creates a mismatch in the channel state between the signaling controller and the Cisco AS5300.

Workaround: There is no workaround.

CSCdw07873

modem dialout controller command not available on AS5800 and AS5850

Symptom: The line command modem dialout controller is not available on the Cisco AS5800 Access Server platform.

Workaround: There is no workaround.

CSCdw18198

Parser cache entry may get deleted when in use

Symptom: Under rare circumstances a router generates a traceback error or reload if both of the following conditions occur:

A background process is processing a parser command (for example: pre-clone command or no pre-clone command for vtemplate), and

Another command is issued at the console (most common is the show interface virt 1 command).

Workaround: There is no workaround.

CSCdw24379

RADIUS attribute Framed-Filter attribute parsing incorrect

Symptom: Framed-Filter attributes with a value which contains multiple "." characters is not parse correctly.

Workaround: Do not use the "." character unless it is used to delimit the suffix with ".in" or ".out".

CSCdw86366

Router crashes during Callerid callback

Symptom: With caller ID callback configurations, the server crashes. This doesn't happen when a single link is called back, but with multiple links.

Workaround: There is no workaround.

CSCdw92035

Cisco IOS forces MICA to turn off EC and Compression with Modem pooling

Symptom: Calls that are routed to nondefault modem pools may not be able to negotiate error correction or compression and may be limited to V.34 speeds.

Conditions: This symptom is observed on a Cisco AS5800 that is running Cisco IOS Release 12.2(8)T and when multiple modem pools exist on the server.

Workaround: Place all modems into the default modem pool or use the dedicated asynchronous mode on asynchronous interfaces to give client modems more time to fall back to asynchronous framing (this works only for PPP connections).

First Alternate Workaround: Disable error correction or compression, or disable both, on client modems.

Second Alternate Workaround: Use resource pooling instead of legacy modem pooling.

CSCdx10977

%SCHED-3-THRASHING:watched message event:AAA ACCT Proc

Symptom: When the clear modem command is issued on the Cisco AS5800 that is running the Cisco IOS Release 12.2(02)XB05 image, there can be %SCHED-3-THRASHING at the watched message event in AAA accounting process.

Workaround: There is no workaround.

CSCdx11089

Change password sequence broken: 12.2T + CS Unix

Symptom: It may not be possible to activate the change password sequence through a Telnet session to a router that is using TACACS+ user authentication.

Conditions: This symptom is observed on a Cisco router that is using a CiscoSecure UNIX (CSUNIX) TACACS+ server and that is running Cisco IOS Release 12.2 T.

Workaround: There is no workaround.

CSCdx18084

spur mem access at np_dsplib_signaling_active_ntf on egress COT call

Symptom: In an SS7 for interconnect on voice gateways configuration, a traceback is seen on the Cisco AS5850 if the customer is doing egress continuity test (COT).

Conditions: If the customer is running Cisco IOS Release 12.2(02)XU and doing egress COT on a Cisco AS5850.

Workaround: There is no workaround.

CSCdx28879

Spurious mem access due to preauth_do_author() for vpdn call initiat

Symptom: When a virtual private dial-up network (VPDN) call is made with authentication, authorization, and accounting (AAA) preauthorization, a traceback is observed because of a spurious memory access made by a preauth_do_author function call.

Conditions: This symptom is observed on a Cisco AS5300 when preauthorization is configured with only the aaa group server radius 7777 command.

Workaround: Configure the dnis required customer profile configuration command.

CSCdx32763

RADIUS decode error when Filter-Id attribute is null terminated

Symptom: A Cisco access server that is running Cisco IOS Release 12.2(4)T or later releases may reject a RADIUS authentication response from a RADIUS server when the profile includes the Filter-ID attribute which is terminated with a NULL.

Workaround: Stop the RADIUS server from including the NULL character at the end of the Filter-ID attribute or to downgrade to mainline Cisco IOS Release 12.2 software.

CSCdx54449

router crashed when 100 concurrent x25 sync telnet sessions issued

Symptom: Router reloads when 100 concurrent x25 sync telnet sessions issued.

Conditions: Only happens with large number simultaneous X25 sync telnet sessions.

Workaround: There is no workaround. This issue is now resolved.

CSCdx56527

Memory leak of 20M/Day until crash

Symptom: A router may reload after a memory leak occurs.

Conditions: This symptom is observed on any Cisco router that is running Cisco IOS Release 12.2 (or Cisco IOS Release 12.2B or Cisco IOS Release 12.2 T). The memory leak is triggered by authentication, authorization, and accounting (AAA) when AAA attempts to enable TCP header compression twice within the same user session.

Workaround: Disable TCP header compression when a RADIUS or AAA database is used.

CSCdx72670

router reload in ip_build_outputQ on clear ip mroute

Symptom: Between the PIM process and the timer wheel process, there is data corruption which causes crash.

Workaround: There is no workaround.

CSCdy07358

Alignment errors in ipfrag_init process

Symptom: A Cisco 7200 router that is running Cisco IOS Release 12.1(15.5) and is configured as an LNS in a VPDN environment may suffer alignment errors in the ipfrag_init function. The problem does not have any adverse reaction on the router but could impact performance slightly.

Workaround: There is no workaround.

CSCdy34419

Getting %DS_MODEM-3-LOW_PARTICLES:Not enough particles messages

Symptom: The following messages may appear on a Cisco AS5800 that is running 12.2(10b):

2w2d: %DS_MODEM-3-LOW_PARTICLES: Not enough particles - modem number:15
particles needed:1 available:0; CTS off
Aug 12 02:47:46.804: %DIAL3-3-MSG:
2w2d: %DS_MODEM-3-OUTPUT_DROP: Output drop - modem number:15 refunded 1;
particle count 0, pool size 11429, queue size 80
Aug 12 02:51:08.165: %DIAL4-3-MSG:

Conditions: Normal modem traffic can lead to these symptoms after few weeks of the router reload.

Workaround: There is no workaround.

CSCdy51329

Problems with modem mgmt introduced by CSCdx48036

Symptom: With the debug csm mod command enabled, the following debug message is now output upon each modem call:

DAS_ST_MODEM_ERR(1/0): modem_mgmt_get_modem_parm: not MICA

Conditions: This message is from a Cisco AS5850 with no MICA boards. All ports are NextPort DSPs.

Workaround: There is no workaround.

CSCdy63815

OLD-CISCO-TS-MIB tsLineUser empty with AAA RADIUS and local user

Symptom: An empty value is returned for the tsLineUser value in the OLD-CISCO-TS-MIB MIB.

Conditions: This symptom is observed on a Cisco router that is running Cisco IOS Release 12.2(2)XB6 with authentication, authorization, and accounting (AAA) RADIUS and that has a local user configuration. The tsLineUser value of the OLD-CISCO-TS-MIB is populated when Cisco IOS 12.1(5)T8 is used.

Workaround: There is no workaround.

CSCdy72086

Torch RSC drops all digital calls after the 421st call is setup.

Symptom: The 421st call cannot be made and existing calls thereafter drop.

Conditions: With a configuration to bring up 450 digital calls, existing digital calls start dropping after the 421st call.

Workaround: Need to configure 'dialer pool-member 1' on serial6/1:15

CSCdy73370

Invalid user info displayed in CallTracker

Symptom: Calltracker records are incorrectly reported for modem calls. The userid, IP address, and mask are wrong.

Workaround: There is no workaround.

CSCdz00204

no aaa nas port extended has no effect

Symptom: With the Cisco IOS Release 12.2(2)XB6 image, the NAS port format is the same (for example "Async1/01*Serial3/0:2") with and without the no aaa nas port extende command configured. With the Cisco IOS Release 12.2(2)XA5 image, this is not a case.

Workaround: There is no workaround.

CSCdz00304

Acct-Authentic attribute not correct in some scenarios

Symptom: RADIUS accounting attribute 45 (Acct-Authentic) may have a wrong value under some circumstances.

Workaround: There is no workaround.

CSCdz01366

Multihop router Crashs with port flap: PPPoA/L2TP multihop

Symptom: A multihop router may reload because of a port flap.

Conditions: This symptom is observed when there are 940 PPP over ATM (PPPoA) sessions with 50 ingress and 10 egress tunnels configured on a Cisco router running Cisco IOS that is employed as a multihop router.

Workaround: There is no workaround.

CSCdz02435

Autoselect PPP loop resulting in AOL client step 3 failures

Symptom: PPP autoselect in a loop results in null username failures.

Conditions: This bug will affect all AS5xxx series of Access Servers.

Workaround: Enable flush-at-activation under the lines and load an image which has the fix for this DDTS.

CSCdz04349

User-name not included in accounting with nocallback-verify

Symptom: When nocallback-verify is configured for a PPP Microsoft callback client, dialing into a Cisco Access Server, it is possible that the username attribute is not included in the AAA accounting records.

Workaround: There is no workaround.

CSCdz17327

NEAT firmware corruption:FIRMWARE_RUNNING/FIRMWARE_STOPPED

Symptom: Intermittently the T1 controller firmware may stop running. Following message will indicate such a problem:

%DSX1-1-FIRMWARE_STOPPED: T1/E1 Firmware is not running
%DSX1-1-FIRMWARE_RUNNING: T1/E1 Firmware is running
%DSX1-1-FIRMWARE_STOPPED: T1/E1 Firmware is not running
%DSX1-1-FIRMWARE_RUNNING: T1/E1 Firmware is running
%DSX1-1-FIRMWARE_STOPPED: T1/E1 Firmware is not running
%DSX1-1-FIRMWARE_RUNNING: T1/E1 Firmware is running
%DSX1-1-FIRMWARE_STOPPED: T1/E1 Firmware is not running
%DSX1-1-FIRMWARE_RUNNING: T1/E1 Firmware is running

Conditions: This is a very rare problem. When this happen the calls may stay up on the affected T1/E1. But it may make the graceful provisioning of new T1/E1 impossible.

Workaround: Reloading the Cisco IOS will initialize the T1/E1 controller firmware.

CSCdz18330

Tacacs cmd authorization doesnt work with directed requests

Symptom: Tacacs+ command authorization on a Cisco router running Cisco IOS Release 12.2(11)T1 fails when used by users that logged in using the Tacacs directed-requests feature (user@<address>). The router incorrectly uses the full username (including the @<address>) to authorize commands against the Tacacs server.

Workaround: There is no workaround.

CSCdz21534

T1 remote line loopback fails on CT3 card

Symptom: A T1 in a channelized T3 port (CT3) dial feature card (DFC) goes into a loopback. This can cause the remote to receive Path Code Violations (PCVs) and sometimes Loss of Signal (LoS).

Conditions: This symptom is observed on a CT3 DFC on a Cisco AS5400 router.

Workaround: Cable a hard loop to test from the network to the T3 of the Cisco AS5400.

CSCdz23256

SYS-2-LINKED: Bad dequeue messages periodically reported on AS5800

Symptom: The following message has been periodically reported on all platforms running Cisco IOS Release 12.2(12.6):

Nov 6 09:22:17.364 CET: %SYS-2-LINKED: Bad dequeue of 62C3B194 in queue 69408DAC
-Process= "<interrupt level>", ipl= 4
-Traceback= 6055A354 604FFAFC 60398F10 60398E44 60B94720 60398C24 6039B380 6039A018 6000F8C4 6015EA80 601624CC 605BDD20 60162358 60B94484 60B92B68 60B295D8

Conditions: Problem happens on all platforms running Cisco IOS Release 12.2(12.6), with active X.25 or LAPB serial connections, when LAPB retransmissions are occurring with moderate-to-heavy traffic.

Workaround: There is no workaround.

CSCdz27817

1Khz tone on ide CAS trunk -19.9 db

Symptom: A T1 channel-associated signaling (CAS) trunk may produce a 1-kHz tone at 19.9 dB while the trunk is in the idle state.

Conditions: This symptom is observed on a T1 CAS trunk that is running Cisco IOS Release 12.2(11)T. This symptom does not affect normal call operation.

Workaround: The problem has been fixed in the latest releases.

CSCdz30790

T3 controller link up/down traps not sent for snmp

Symptom: On a Cisco AS5400 router, Simple Network Management Protocol (SNMP) linkchange traps are not generated for a T3 controller up and down state changes.

Conditions: This symptom is observed on a Cisco AS5400 router that is running a c5400-is-mz.122-2.XB9 image of Cisco IOS software and that is configured with the following router configuration command:

snmp-server enable traps snmp authentication linkdown linkup coldstart warmstart

Workaround: There is no workaround.

CSCdz34487

tacacs+ password change sequence broken

Symptom: The password change sequence does not work as expected when it is used with Cisco Secure Access Control Server software. The user can still access the router with the old password. User can change the existing password to a new password at a later time.

Conditions: This symptom is observed on a Cisco router that is running Cisco IOS Release 12.2(11)T. This problem was not noticed in 12.2(13)T image with Cisco Secure Access Control Server running on an NT box.

Workaround: There is no workaround.

CSCdz38708

5800 with E1R2 may not accept modem calls

Symptom: When terminating incoming E1 R2 calls on a Cisco AS5800 Access Server with MICA modems, a large percentage (up to 100%) of calls may fail. Debugging on the NAS shows that ANI/DNIS collection succeeds and the call is cleared by the switch shortly after sending the line answer ABCD bits. Debugging on the switch side shows that the interregister signaling answer signal (B6 by default) is never terminated before sending the line answer signal.

Conditions: This problem is seen on a Cisco AS5800 series Access server using MICA modems and configured for compelled E1 R2 signaling. The problem is not seen on Cisco AS5300 or AS5850 Access Servers or on Cisco AS5800 with NextPort card, and it does not occur with sem- or non-compelled E1 R2 signaling or any other signaling type. In addition, this problem only affects incoming calls.

Workaround: There is no workaround.

CSCdz39284

SIP: PROTOS Test Group 5 - Test Cases 330 to 435 causes as5350 crash

Symptom: Multiple Cisco products contain vulnerabilities in the processing of Session Initiation Protocol (SIP) INVITE messages. These vulnerabilities were identified by the University of Oulu Secure Programming Group (OUSPG) "PROTOS" Test Suite for SIP and can be repeatedly exploited to produce a denial of service.

Conditions: This issue is observed on Cisco devices which contain support for the SIP protocol and are running vulnerable versions of software.

Workaround: Cisco will be making free software available to correct the problem as soon as possible. Additional workarounds will be documented in the Security Advisory.

This advisory is available at:

http://www.cisco.com/warp/public/707/cisco-sa-20030221-protos.shtml

CSCdz40483

%SYS-2-WATCHDOG: Process aborted on watchdog timeout, process = IP I

Symptom: A Cisco router permanently pauses with a watchdog timer under normal operation.

Conditions: This symptom is observed when the router is a voice endpoint with active calls.

Workaround: There is no workaround.

CSCdz44203

Dynamic Dialer map not created with aaa authentication if-needed

Symptom: Users connecting to a Cisco AS5350, using a post dial terminal window for authentication, may not be able to ping the Cisco AS5350 after connecting. This problem only occurs with "aaa authentication ppp <list> if-needed" configured. The root of the problem is that a dynamic dial map is not created for the user. This can be seen with the show dialer map command. The other symptom of this problem is that there will be no output packets on the async interface to which the user is connected.

Workaround: Reconfigure the router to use virtual-profiles, or remove "if-needed" from the AAA authentication command.

CSCdz45885

AAA POD not disconnecting client requests with 8-byte session id

Symptom: An authentication, authorization, and accounting (AAA) packet of disconnect (POD) server may not disconnect a client request that has an 8-byte session ID.

Conditions: This symptom may occur on a Cisco AS5400 or a Cisco AS58500 that is functioning as a triple A POD server.

Workaround: There is no workaround.

CSCdz51403

NAS-port attribut 5 has been changed for format C

Symptom: VTY interface is not supported with extended NAS-PORT format.

Workaround: There is no workaround.

CSCdz51941

Call drops once the Card is OIRed in case of NFAS.

Symptom: On a Cisco AS5800 when a trunk which has been configured for Primary NFAS is inserted back after OIR, the calls on the other cards, which are configured for NFAS of the same group, could fail, especially in the case of a TD/TV solution.

CSCdz54240

poor performance on MLP with h/w compression (single channel ISDN)

Symptom: The transportation of files across a single BRI connection of an E1 line may result in poor performance.

Conditions: This symptom is observed on a Cisco 3600 series router that is running Cisco IOS Release 12.2(02)XB7.

Workaround: There is no workaround.

CSCdz56776

Outgoing PPP frames are stuck on MLPPP

Symptom: If Multilink PPP call(MLPPP) is disconnected by cause except Normal call clearing, no frames are send out on subsequent calls and the output queue may be stuck.

Conditions: The symptoms occur under the following conditions:

You are running Cisco IOS Release 12.2 and Cisco IOS Release 12.2 T

MLPPP is enabled on ISDN interface (BRI and PRI).

Dialer profile and multiple dialer interfaces belonging to the same dialer pool number are configured.

Workaround: Use the no fair-queue command on physical interfaces.

CSCdz61141

MPPE fails with RADIUS

Symptom: Microsoft Point-to-Point Encryption (MPPE) does not work when RADIUS is used for authentication and authorization. The user is able to authenticate and MPPE is negotiated, but traffic will not pass through unless MPPE is disabled or local authentication is used.

Conditions: This symptom occurs when MPPE is used with RADIUS to perform authentication and authorization.

Workaround: There is no workaround.

CSCdz61543

Remove 64K rejection for 1AESS

Symptom: Calls coming in on 1AESS trunks get rejected by the Cisco AS5x00 access servers.

Conditions: Incoming calls on 1AESS trunk lines will fail to connect. Trunks coming from other switch types will not be effected by this bug.

Workaround: There is no workaround.

CSCdz70933

Filter-Id from preauthentication not applied with auth-required=0

Symptom: When the Filter-Id attribute is provided during preauthentication, it is accepted, but not applied to the virtual access interface. When the same attribute is provided during PPP authentication, it is applied OK.

Workaround: There is no workaround.

CSCdz71219

Input-queue wedge intermittently

Symptom: Intermittent problem on Virtual-Access interfaces. The input-queue becomes wedge, for example:

input queue 11/10

Increasing the input-queue size does not help.

Workaround: There is no workaround.

CSCdz72678

mgcp-nas-pkg calls generate zero values for RADIUS acct attributes

Symptom: Media Gateway Control Protocol (MGCP) network access server (NAS) package calls may cause the following RADIUS accounting attributes to contain zero values:

Acct-Input-Octets

Acct-Output-Octets

Acct-Input-Packets

Acct-Output-Packets

Data-Rate

Ascend-Xmit-Rate

Presession-Packets-Input

Presession-Packets-Output

Presession-Octets-In

Presession-Octets-Out

Conditions: This symptom is observed on a Cisco AS5400 that is running Cisco IOS Release 12.2(2)XB8 or Cisco IOS Release 12.2 T.

Workaround: There is no workaround.

CSCdz88409

Router crashed during weak RADIUS service

Symptom: Cisco C5800 Router running Cisco IOS Release 12.2(2)XB10 crashed during a period of weak RADIUS service that provocated high session flapping.

Workaround: There is no workaround.

CSCdz89543

Missing accounting stop record with LSDO and Multilink PPP

Symptom: In a Large-Scale Dial-Out (LSDO) setup in which the called site (remote site) is configured to add additional member links to the Multilink PPP (MLP) connection, the initial call to the remote site via LSDO may not trigger an accounting stop record when the call terminates.

Conditions: This symptom is observed when the customer premises equipment (CPE) adds additional links to the multilink bundle that is built by the initial LSDO call. If there is only one LSDO call or if all member links are initiated by the remote site (LSDO is not used), stop accounting records are correctly generated for all member links.

Workaround: There is no workaround.

CSCdz89669

AAA Accounting not sent for multilink isdn calls, when MSCB confd

Symptom: When an ISDN dial-in client negotiates callback and multilink, and the callback is not configured for that user, the authentication, authorization, and accounting (AAA) records may not be sent.

Conditions: This symptom is observed on a Cisco router that is running Cisco IOS Release 12.2 T.

Workaround: There is no workaround.

CSCea02355

rare ip packets may cause input queue wedge

Cisco routers and switches running Cisco IOS software and configured to process Internet Protocol version 4 (IPv4) packets are vulnerable to a Denial of Service (DoS) attack. A rare sequence of crafted IPv4 packets sent directly to the device may cause the input interface to stop processing traffic once the input queue is full. No authentication is required to process the inbound packet. Processing of IPv4 packets is enabled by default. Devices running only IP version 6 (IPv6) are not affected. A workaround is available.

Cisco has made software available, free of charge, to correct the problem.

This advisory is available at

http://www.cisco.com/warp/public/707/cisco-sa-20030717-blocked.shtml

CSCea04377

calltracker data leaks to the console when quiet option is set

Symptom: When calltracker call-record terse or verbose configured with "quiet" option, the calltracker data leaks to the console. Specially with logging console and calltracker call-record verbose quiet configured, the CPU utilization jumped up from ~10% to ~99%.

Conditions: Calltracker call-record terse or verbose configured with "quiet" option.

Workaround: Disable the logging console and the CPU utilization would dropped down to normal range. Also with image build from release which has CSCdy81947 integrated and provides support for [no] logging queue-limit [qsize] CLI, we can use this CLI to increase the queue-limit from default value of 100 to 1000 and we will not see this issue. This DDTS is still not available on Cisco IOS Release 12.2(2).XB images.

CSCea12136

AS5850: Silent packet drops from GigabitEthernet to Virtual-access

Symptom: Some dialin users connecting to a Cisco AS5850 are unable to reach external destinations. The packets are sent, but the return packets entering the GigabitEthernet egress interfaces are silently dropped on the Cisco AS5850.

Those drops are neither reported with show cef drop nor do any of the interface drop counters increase. The incoming packet counter on the GigE as well as the outgoing packet counter on the vaccess increase as packets arrive, but they do not arrive at the user.

All CEF/FIB and adjacency entries look normal. This problem is seen only for some active sessions, other sessions are working normally. Multilink sessions (even with a single channel only) have not been reported failing.

Conditions: This problem is only seen on a Cisco AS5850 running Cisco IOS Release 12.2(2)XB10. The problem is not seen on a Cisco AS5800 running the same software release.

Workaround: The user must disconnect and reconnect to restore connectivity.

CSCea12966

function aaa_attr_list_ptr_copy_to_req does not support merged lists

Symptom: Function aaa_attr_list_ptr_copy_to_req incorrectly strips off any additional attribute lists connected to the list passed in. This causes attributes lists to be lost, resulting in missing attributes being sent to AAA Servers.

Workaround: There is no workaround.

CSCea14392

Need to commit Nextport Module Code 3.2.22.18

Request to commit new module code to bundle in Cisco IOS releases for the NextPort based Cisco AS5350/AS5400/AS5850 platforms.

This module code 3.2.22.18 addresses the following issues for customers:

CSCdy55561 2 Modems marked BAD after V.110 CSM parameter failure

CSCdx71846 3 g.726 interop w/non-Cisco GW shows misordered 4 bit samples in Pload

CSCdx69453 3 Voice and Fax-Relay info field size range from 0 is invalid

CSCea19087

CALLTRKR-6-CALL_RECORD not displayed for a modem-pool call with CAS

Symptom: A Cisco AS5300 may not display some Calltracker information for a modem call.

Conditions: This symptom is observed on a Cisco AS5300 that is running Cisco IOS Release 12.2(2)XB10 or Cisco IOS Release 12.2(13)T and is configured for channel-associated signaling (CAS) with modem pooling. This is observed, in particular, when the call is routed to a configured modem pool instead of to the default modem pool. The Calltracker messages look like the following messages:

CALLTRKR-6-CALL_RECORD

and

CALLRECORD-3-MICA_TERSE_CALL_REC

However, when the symptom occurs, the first message is omitted.

Workaround: Configure the Cisco AS5300 for ISDN (PRI) instead for CAS.

First Alternate Workaround: Do not configure modem pooling.

Second Alternate Workaround: Ensure that the call is routed to the default modem pool.

CSCea23484

VPDN rejecting 127.0.0.x address as source-ip

Symptom: IP addresses of the "127.0.0.x" type may be rejected by a virtual private dial-up network (VPDN) to be used as the source IP address for VPDN tunnels.

Conditions: This symptom is observed on a Cisco AS5400 or Cisco AS5800.

Workaround: There is no workaround.

CSCea24574

VSA not processed if sent with tagged tunnel attributes

Symptom: AAA may not process VSA if sent with tagged L2TP tunnel attributes.

Conditions: This symptom is observed on a Cisco AS5400 or Cisco AS5800.

Workaround: There is no workaround.

CSCea28396

AS5300 reloads while sending aaa accounting request

Symptom: A router may reload when sending an authentication, authorization, and accounting (AAA) request to a TACACS+ server.

Conditions: This symptom is observed on a Cisco AS5300 universal access server that is running Cisco IOS Release 12.2XB(10) and Cisco IOS Release 12.2 T.

Workaround: There is no workaround.

CSCea28958

Function to manipulate attribute lists does not merge correctly

Symptom: While copying an AAA attribute list into an event, the copy function strips off any additional attribute lists connected to the list passed in. This causes attributes lists to be lost, resulting in missing attributes being sent to AAA Servers.

Workaround: There is no workaround.

CSCea41989

AS5400/AS5350 - ANI/DNIS Delimiter (sig-class) CAS for CT1 is broken

Symptom: A user-configured signaling class template may not be not used during incoming and outgoing channel-associated signaling (CAS) calls. Instead, the default signaling template is used.

Conditions: This symptom is observed in Cisco IOS Release 12.2 and Cisco IOS Release 12.2 T on a Cisco AS5350 and a Cisco AS5400.

Workaround: There is no workaround.

CSCea45343

Not able to manually shutdown modem/spe in BAD state

Symptom: When a modem in bad state is shutdown, the show modem command reports the state as BAD and not as SHUT.

Further Problem Description: The states of busy out and shut were clubbed together as 'b'. The two were segregated as part of DDTS CSCdr31105. If a modem in bad state is shut down, the show modem command shows the state as 'B' and not as 'S'. But if a modem is shut down, it really doesn't matter what state the modem is in. So the state should be shown as 'S'.

Workaround: There is no workaround.

CSCea49108

MICA Boardware does not recover after crash

Symptom: If boardware crashes in some scenerios, Cisco IOS does not know and therefore cannot recover.

Impact: Failed calls into that carrier card (up to 120 modems impacted).

Workaround: Use the copy flash modem command with the file:

system:/ucode/mica_board_firmware

CSCea52804

bus error at auth_tx_failure

Symptom: A Cisco AS5350/AS5400 running Cisco IOS Release 12.2(2)XB7 crashes with bus error at auth_tx_failure.

Workaround: There is no workaround.

CSCea53600

authorization failure for terminal login call with per-user DNS/WINS

Symptom: Issue with terminal server login where a RADIUS assigned DNS or WINS server (ie. per-user dns/wins) causes authorization to fail.

Workaround: There is no workaround.

CSCea61814

bearer capability changed for outgoing hairpinned call

Symptom: The bearer capability is changed for outgoing hairpinned call.

Workaround: There is no workaround.

CSCea66630

COT_TP_IN test fail resulting channels in maintenence pending

Symptom: The first COT_TP_IN test failed right after reload and the Cisco AS5300 never received COT_TP_OUT from softswitch, putting the channel in maintenance pending state. The timer in COT_TP_IN test should bring the channel to idle even if it does not receive the COT_TP_OUT from softswitch.

Workaround: There is no workaround.

CSCea79604

buffer size mismatch between MICA boardware and Cisco IOS

Symptom: The buffer size used by Cisco IOS to send data to the MICA carrier card is larger than the maximum buffer size defined by the carrier card software. If Cisco IOS sends a buffer which exceeds the maximum size set by the carrier card, the carrier card software may crash. If this software crashes, communication with all modems on the board will be lost.

Conditions: This mismatch in buffer size affects all images starting with 12.2M and 12.2 T.

Workaround: The router must be reloaded.

CSCin03921

The 872uut crashes inconsistently during cbwfq tests

Symptom: Adding or removing a service policy to a dialer interface may infrequently cause a spontaneous reload of the router.

Workaround: There is no workaround. However relying on experience with similar issues (involving reconfiguring a dialer on the fly), the suggestion is that either or both of the following steps might help:

Stop generating traffic through the interface

Shutdown the dialer interface when changing the service policy


Open Caveats—Cisco IOS Release 12.2(2)XB10

There are no open caveats specific to Cisco IOS Release 12.2(2)XB10 that require documentation in the release notes.

Resolved Caveats—Cisco IOS Release 12.2(2)XB10

All the caveats listed in this section are resolved in Cisco IOS Release 12.2(2)XB10. This section describes only severity 1 and 2 caveats and select severity 3 caveats.

Table 9 Resolved Caveats for Cisco IOS Release 12.2(2)XB10 

DDTS ID Number
Description

CSCdt64681

EIGRP route stuck in RT after neighbor down over ISDN:

Symptom: Cisco 7200 running Cisco IOS Release 12.1(6) with PRI and multiple dialer interfaces. Two dialer neighbors advertise a prefix which is stuck in topology table/routing table once the neighbors are down.

Workaround: Clearing the route makes it come back.

CSCdu26701

Compression & CEF on same int should not be allowed:

Symptom: If you configure compress mppc on an interface and configure ip cef globally, IP fast switching is disabled. This affects connections that are not configured for compression to be process switched just like the compression connections, which adversely affects performance.

If you disable compression, enable fast-switching, and re-enable compression, the interface incorrectly allows fast-switching simultaneously with compression.

Workaround: Do not configure compression on interfaces you want to have fast-switched.

CSCdv00338

Calls not disconnected (show isdn active) when idle time expires:

Symptom: ISDN calls on NFAS signaled E1/T1 which arrive on B-channel 16 (for E1) or 24 (for T1) are not purged from the call-history MIB shown by show isdn active upon disconnect but are still shown as active.

This can cause the ISDN process to consume more and more memory and CPU load in order to maintain the growing list.

Workaround: Deactivate call-history-mib using the commands:

call-history-mib max-size 0

call-history-mib retain-timer 0

CSCdx62491

CISCO-AAA-SESSION-MIB casnActiveTable: getnext returns wrong OID:

Symptom: The getnext command returns the wrong OID when retrieving an object from the casnActiveTable of the CISCO-AAA-SESSION-MIB and no instance is given.

> getnext -v2c 10.89.152.43 public casnUserId
casnTotalSessions.0 = 2
> getnext -v2c 10.89.152.43 public casnUserId.0
casnUserId.1 =
> getnext -v2c 10.89.152.43 public casnUserId.1
casnUserId.2 = cisco

Conditions: This problem only occurs when no instance is given in the getnext request.

Workaround: There is no workaround.

CSCdx86284

Resend OOS service message after RESTART:

Symptom: If an ISDN B channel has been set out of service (via the D channel interface command "isdn service"), and if the router should subsequently receive from the switch a RESTART message for that channel, then the router will think that the channel is still OOS, while the switch thinks that it is not OOS any more. The result will be that the switch may offer a call to the router on that channel, which call will be rejected by the router with "Requested circuit/channel not available".

Instead, after receiving the RESTART message for an OOS channel, the router should refrain from acknowledging RESTART, but instead should reissue the SERVICE message, to restore the channel to the out-of-service state.

Workaround: There is no workaround.

CSCdx90988

Memory leak in ISDN:

Symptom: A leak with the ISDN process may be observed on a router after about three days. The router reloads because of a lack of memory resources after about 14 days.

Conditions: This symptom is observed on a Cisco router that is running Cisco IOS Release 12.2(10).

Workaround: Reboot the router at a time when there is low traffic.

CSCdy34494

NAS-Identifier value isnt correct in attribute_32 test.:

Symptom: The NAS-Identifier value is not correct because the value can only take 33 characters.

Workaround: There is no workaround.

CSCdy48813

Outgoing call failed due to dialer DNS reverse-lookup failed:

Symptom: For dialout, the outgoing call fails due to DNS reverse-lookup when dialer DNS is used on the dialer interface. The problem didn't appear in Cisco IOS Release 12.2(2)XB5.

Workaround: There is no workaround.

CSCdy63815

OLD-CISCO-TS-MIB tsLineUser empty with AAA RADIUS and local user:

Symptom: OLD-CISCO-TS-MIB tsLineUser is empty in Cisco IOS Release 12.2(2)XB6 with AAA RADIUS and local user configuration. The same configuration works with Cisco IOS Release 12.1(5)T8, and the tsLineUser value is populated.

Workaround: There is no workaround.

CSCdy68133

Async Call fails to come up when no preauth is configured:

Symptom: Modems calls will be rejected with no resource available.

Conditions: This only happens if preauthorization is not configured.

Workaround: Configure preauthorization for incoming calls. This may not be possible in all networks.

CSCdy85971

wrong SDP in 200 ok reply to a re-invite to conference:

Conditions: This problem happens every time a mid-call INVITE is received to revert from a negotiated DTMF-rely payload type to Inband Voice.

Symptom: In response to the mid-call INVITE, part of the old negotiated payload type is advertised in the 200 ok. The SDP looks as follows (Note the missing encoding name) :

a=rtpmap:96 /8000 a=fmtp:96 0-15

Workaround: There is no workaround.

CSCdz12110

ANI configured is not followed for E1-R2 outgoing call:

Symptom: For an outgoing call, Cisco AS5400 running 12.2(12a) may send the same DNIS and ANI to PSTN switch without following the ANI configured under cas-custom under controllers

CSCdz12711

NAS timedout user reported with incorrect prog. /discon. code:

Symptom: Incorrect progress / disconnect code is reported for a user timing out by NAS with no RADIUS response.

Workaround: There is no workaround.

CSCdz19909

RADIUS interim-update records not being sent correctly:

Symptom: The customer is using Cisco 7206VXR. The RADIUS interim-update records have been enabled with the following global command:

aaa accounting update periodic 1440

The DSL router is supposed to send an update record for every active session every 24 hours but is producing inconsistent results instead. For many sessions that are active for more than a day, no update records are ever sent. For sessions where update records are sent, the time interval between updates is inconsistent.

Workaround: There is no workaround.

CSCdz19944

MGCP T38 inhibit does not suppress T38 capability:

Symptom: On Cisco AS5400 with Cisco IOS Release 12.2(12.14)T or Cisco IOS Release 12.2(2)XB8, disabling T.38 through mgcp fax t38 inhibit and/or fax t38 inhibit under voice service voip does not suppress the gateway's advertisement of T.38 as a capability.

Workaround: There is no workaround.

CSCdz24736

Multilink PPP reporting master channel with a progress code 65:

Symptom: Multilink PPP should report the master channel with a RADIUS accounting progress code of 60.

Workaround: There is no workaround.

CSCdz45885

AAA POD not disconnecting client requests with 8-byte session id:

Symptom: AAA POD is not disconnecting client requests with 8-byte session-id.

CSCin23107

Possible memory leaks during async callback:

Symptom: On Cisco AS5400 universal access servers running Cisco IOS Release 12.2(2)XB8 or 12.2(12.14)T, memory leaks associated with async callback are possible.

Workaround: There is no workaround.


Open Caveats—Cisco IOS Release 12.2(2)XB9

Cisco IOS Release 12.2(2)XB9 is not distributed for widespread availability.

Resolved Caveats—Cisco IOS Release 12.2(2)XB9

Cisco IOS Release 12.2(2)XB9 is not distributed for widespread availability.

Open Caveats—Cisco IOS Release 12.2(2)XB8

This section documents possible unexpected behavior by Cisco IOS Release 12.2(2)XB8 and describes only severity 1 and 2 caveats and select severity 3 caveats.

Table 10 Open Caveats for Cisco IOS Release 12.2(2)XB8 

DDTS ID Number
Description

CSCdx05186

Sympton:- After about 30+ hours of stress testing Cisco AS5800 and Cisco AS5850 universal gateways start rejecting calls and "%CSM-1-NO_CSM_CALL_INFO: NO call control block" traceback is seen.

Conditions: This defect was seen on Cisco AS5850 and Cisco AS5800 universal gateways during sterss testing. The Cisco AS5850 universal gateway was handling about 500 sustained calls being placed at about 5cps. This problem is seen after about 30+ hrs of stress testing. The trace backs are seen as the calls are being rejected. At this stage the system will be unable to sustain more than 50(approximately) calls. This is seen on systems handling SS7 calls and configured to get tunnel information from RPMS.

Workaround: The only workaround is to reload the box. It has been seen that the box starts functioning at its capacity after reload.

CSCdx29945

Cisco AS5800 universal gateway running Cisco IOS Release 12.2(2)XB5 Apr10th prefcs ios can reload due to corrupted Program Counter at DEADBEEF under workload/stress.

CSCdx33071

V120 Calls fail when VPDN is enabled for DNIS screening. This might be service impacting.

Workaround : There is no workaround.

CSCdx37301

Symptom: On reloading Cisco AS5850 universal gateway route-switch controller (RSC), the universal port feature card (UP324) may unexpectedly crash.

Conditions: Reload Cisco AS5850 RSC.

Workaround: There is no known workaround to this problem at this time.

CSCdx52766

In a multilink multichasis scenario, if there exists a route among the SGBP dial-in NASes that goes through a dial-in MLPPP client and back to a NAS, either through a dial-out NAS, a direct LAN, or other connection, we may hit a race condition leading to a stack overflow and subsequent software forced crash. A workaround is to ensure that such routes are not present.

CSCdz00534

Symptom: 12.2.2XB7+ L2TP is incorrectly indicating "service up" to Calltracker with a service type of PPP.

Conditions:This behavior happens for L2TP calls.

Workaround:There is no workaround.


Resolved Caveats—Cisco IOS Release 12.2(2)XB8

All the caveats listed in this section are resolved in Cisco IOS Release 12.2(2)XB8. This section describes only severity 1 and 2 caveats and select severity 3 caveats.

Table 11 Resolved Caveats for Cisco IOS Release 12.2(2)XB8 

DDTS ID Number
Description

CSCdw93992

A Cisco Layer 2 Tunneling Protocol (L2TP) access concentrator (LAC) may fail to send accounting records for a PPP over ATM (PPPoA) call after the call has been forwarded via L2TP to an L2TP network server (LNS). The LNS drops the call by sending a Call Disconnect Notification (CDN) message to the LAC.

Workaround: Clear the virtual access interface for the call on the LAC.

CSCdx47143

Symptom: Some E1 controller ports may remain down after a router is booted up.

Conditions: This symptom is observed on a Cisco AS5800 access concentrator that is running Cisco IOS Release 12.2(2)XB5.

Workaround: Enter the shutdown interface command followed by the no shutdown interface configuration command on the E1 controller that has paused indefinitely in the down state.

CSCdy00247

Symptom: The modemcap AT command string may be in the input buffer of a line when the line comes up. As a result, this string -—rather than actual user data received from the client modem-— may be used for character mode authentication.

Conditions: This symptom is observed on a Cisco AS5800 that has autoconfiguration enabled on the modem lines.

Workaround 1: Enter the flush-at-activation command.

Workaround 2: Be sure that the modemcap entry configured on the line involves sending an AT command no longer than 58 characters.

CSCdy06029

When using MS-Callback with IOS 12.2(2)XB6 and the 'callback-noverify' option, the NAS fails to apply Framed-IP-Address or any AV-Pairs associated with that user.

CSCdy21198

NAS is running almost 700 calls, a mixture of Analog, SYNC PPP, and multilink calls. After about 14-16 hours of stress testing, The NAS reloads @ muti_session_add_link.

CSCdy22040

Dead Virtual-Access interfaces might be seen on Cisco AS5800 under stress. This can be service impacting over a period of time as NAS will eventually run out of Virtual-Access interfaces.

CSCdy35836

Issue: On Cisco AS5800 platform during long duration test it is found 5800 hits "No more SWIDB allowed" issue and calls fails.

Workaround: There is no workaround.

CSCdy39663

Cisco AS5800 router crashed with outb-telnet_aaa_acct_get_dynamic_attrs routine. This crash looks like regression caused by CSCdx87139. If a router running IOS version which has fix for CSCdx87139, it can get crashed by this bug.

Workaround: There is no workaround.

CSCdy50103

Attributes 42 or/and 43 might carry negative values with aaa accounting exec default none IOS command configured on the NAS. This frequency of occurrence of this bug is the range of one Accounting record out of ten.

Workaround: There is no workaround.

CSCdy51116

In IOS 12.2(12.5)T or later a router which does not have AAA configured may unexpectedly reload when a user attempts to telnet from the router to another device.

Workaround: Enable AAA.

CSCdy52842

Failed MLP calls can cause phantom Virtual-access interface issues.

Workaround: Use 'ppp timeout ncp x' but would like to see if we still have any side effect of this issue since some of these interface do get recycled if a call is received from the same user again.

CSCdy69192

Cisco AS5300 server encounters system crash when RADIUS authentication is used for authenticating asynchronous call.

Workaround: Use Local or TACACS+ authentication.

CSCdy71629

The task_id attribute in AAA accounting record might be wrong if the task_id is greater then 9999.

Workaround: There is no workaround.


Open Caveats—Cisco IOS Release 12.2(2)XB7

This section documents possible unexpected behavior by Cisco IOS Release 12.2(2)XB7 and describes only severity 1 and 2 caveats and select severity 3 caveats.

Table 12 Open Caveats for Cisco IOS Release 12.2(2)XB7 

DDTS ID Number
Description

CSCdy14689

In Cisco IOS Release 12.2(2)XB, Cisco IOS Release 12.2(4)T, and later Cisco IOS codes, the router does not send RADIUS connection accounting attribute 46 for TCP clear calls or for any outbound telnet connections from the router. The is issue is only with Telnet connections. Regular PPP calls accounting records do contain this attribute.

Workaround: There is no workaround.

CSCuk34949

A Cisco router may generate a large number of alignment errors when TCP Header Compression is configured in conjunction with L2TP and Multilink PPP.

Workaround: Disable header compression, both in the local configuration (use the interface command no ip rtp header-compression) and in any RADIUS/AAA database.


Resolved Caveats—Cisco IOS Release 12.2(2)XB7

All the caveats listed in this section are resolved in Cisco IOS Release 12.2(2)XB7. This section describes only severity 1 and 2 caveats and select severity 3 caveats.

Table 13 Resolved Caveats for Cisco IOS Release 12.2(2)XB7 

DDTS ID Number
Description

CSCdk31736

PPP authentication requests with no username are not forwarded to the TACACS+/RADIUS server. This may prevent you from authenticating people by Caller ID.

CSCdv21918

A router may reload if netflow-data is exported to a multicast address.

Workaround: Do not configure a multicast address; use a unicast address instead.

CSCdv27734

New PPP configuration commands are provided which provide control over the negotiation and application of the LCP configuration options for HDLC Address and Control Field Compression (ACFC) and PPP Protocol Field Compression (PFC).

CSCdw00055

The non-variable-length dial-plan matching character `$' permits a user to force a match on a destination-pattern consisting of a fixed number of digits. For example, use the following configuration:

!
dial-peer voice 1 voip
destination-pattern 01152....$
session target ipv4:IP_ADDR_RTR1
ip precedence 5
!
dial-peer voice 2 voip
destination-pattern 01152......
session target ipv4:IP_ADDR_RTR2
ip precedence 5
!

The user in this situation has calls to phone numbers which share the same first set of prefix digits but whose complete set of digits are different in number. In the example above, calls to RTR1 have nine digits starting with `01152' while calls to RTR2 have 11 digits starting with `01152'. To eliminate the ambiguity as to which dial-peer to match, the `$' is used so that a call to RTR2 will not match on dial-peer 1. This configuration works in Cisco IOS Release 12.1 images which support the `$' dial-peer matching character and Cisco IOS Release 12.2(1a).

Starting in Cisco IOS Release 12.2(1.1) and in Cisco IOS Release 12.2(2)T, the dial-plan no longer permits a destination-pattern terminated with the `$' character to be matched at all, and hence no calls using that dial-peer will complete.

Workaround: Configure the destination-patterns which end in `$' to end in `T?$':

!
dial-peer voice 1 voip
destination-pattern 01152....T?$
session target ipv4:IP_ADDR_RTR1
ip precedence 5
!
dial-peer voice 2 voip
destination-pattern 01152......
session target ipv4:IP_ADDR_RTR2
ip precedence 5
!

CSCdw93050

The problem is transparent to the customer and is involved with the IOS MLP/PPP architecture.

CSCdx15859

Calltracker, show call calltracker active, and ... history commands display extraneous comma after authentication time.

CSCdx33166

During LSDOCallback, the sessions on the server side go down due to which callback already exists debugs can be seen in the logs inhibiting callback from occurring.

Workaround: There is no workaround.

CSCdx41454

Symptom: Router applies the ip tacacs source-interface configuration only to the first tacacs server in the server list and fails to use the IP address for other configured servers.

Conditions: When the primary TACACS server is not available, the router will attempt for the next TACACS server in the list. While connecting to the secondary TACACS server, the router ignores the ip tacacs source-interface configuration and it uses the IP address of the outgoing interface.

The router is expected to use the IP address configured through ip tacacs source-interface command as source address, while connecting to the TACACS server, including the secondaries.

Workaround: A workaround is possible using NAT. The user can apply NAT for the TACACS packets by the following configuration.

interface outbound interface to the tacacs server
ip nat outside
!
ip nat inside source list 102 interface Loopback0 overload
access-list 102 permit tcp any any eq tacacs

CSCdx81130

Microsoft Callback negotiation may fail with particular clients. This is due to a minor difference between Cisco's implementation of the Microsoft Callback server and the original implementation by Microsoft in a detail that is not clearly specified in the draft RFC. While this particular problem does not seem to impact Microsoft Windows clients requesting for callback, it has been observed with a 3Com OfficeConnect LAN modem that failed to negotiate MS callback with a Cisco NAS.

Workaround: There is no workaround.

CSCdx93324

The H.323 gateway may crash accessing invalid memory location.

Workaround: There is no workaround.

CSCdy01787

When MTU configuration is manually overridden the EAP proxy client may not be able to appropriately size frames for the client's MRU.

Workaround: Do not adjust the MTU on the router.

CSCdy05296

The port information provided on a Cisco AS5350 universal gateway, Cisco AS5400 universal gateway, or Cisco AS5850 universal gateway on modems within RADIUS attribute 5 using either nas-port format a or b for async calls provide the true port information (as in slot/port) and not the TTY line number of the modem which previous generation dial platforms provided. This is causing problems for service providers using a variety of Cisco dial platforms as they are inconsistent in the information being relayed on the various platforms Cisco sells.

Workaround: There is no workaround.

CSCuk36415

Symptom: RTP packets queued from the fast switching path will be sent uncompressed.

Workaround: There is no workaround.


Open Caveats—Cisco IOS Release 12.2(2)XB6

This section documents possible unexpected behavior by Cisco IOS Release 12.2(2)XB6 and describes only severity 1 and 2 caveats and select severity 3 caveats.

Table 14 Open Caveats for Cisco IOS Release 12.2(2)XB6 

DDTS ID Number
Description

CSCds37794

Router crash due to memory corruption with compression in T1-CAS env

Symptom: System may reload due to memory corruption when having traffic.

Conditions: when TCP header compression and predictor compression are enabled. Tearing down calls from the caller side.

Workaround: There is no workaround.

CSCdu79111

TCL APP processes take too much cpu when making +7cps debicard calls

Symptom: When system running debitcard application with bursty traffic of 15+ call per second back-to-back, IVR processes such as TCL APP take too much cpu causing a high overall cpu utilization.

Workaround: Control incoming calls to avoid bursty traffic and turn on Call Admission Control to prevent catastrophic errors at high cpu utilization.

CSCdx05186

%CSM-1-NO_CSM_CALL_INFO and traceback while teardown calls

Symptom: After about 30+ hours of stress testing Cisco AS5800 and Cisco AS5850 start rejecting calls and "%CSM-1-NO_CSM_CALL_INFO: NO call control block" tracback is seen.

Conditions: This defect was seen on Cisco AS5850 and Cisco AS5800 during sterss testing. The Cisco AS5850 was handlig about 500 sustained calls being placed at about 5cps. This problem is seen after about 30+ hrs of stress testing. The trace backs are seen as the calls are being rejected. At this stage the system will be unable to sustain more than 50(approximately) calls. This is seen on systems handling SS7 calls and configured to get tunnel information from RPMS.

Workaround: The only know workaround at this stage is to reload the box. It has been seen that the box start's functioning at its capacity after reload.

CSCdx52766

crash due to memory corruption

In a multilink multichasis scenario, if there exists a route among the SGBP dial-in NASes that goes through a dial-in MLPPP client and back to a NAS, either through a dial-out NAS, a direct LAN, or other connection, we may hit a race condition leading to a stack overflow and subsequent software forced crash.

Workaround: Ensure that such routes are not present.

CSCdx58001

Router crashes @fib_acl_check with config FastE ip mroute-cache

Cisco AS5800 might get reload when configururing FastEthernet Interface (which the VoIP traffic flows) with ip mroute-cache.

The symptom occurs only on 12.2(2)XB5 image: c5800-p4-mz.122-2.XB5.

Workaround: Configuring FastEthernet Interface with no ip mroute-cache on both ORIGINATE and TERMINATE GATEWAY.

CSCdx60767

Unexpected packet forwarding thru MCMLP L2TP tunnel

In case of an MCMLP call, twice the number of user data packets will be transmitted back and forth over the L2TP tunnel virtual-access interface. However the virtual-access interface of the multilink bundle will show the correct number of packets that were expected to be transmitted in both input and output directions. Apparently, the defect is not service impacting.


Resolved Caveats—Cisco IOS Release 12.2(2)XB6

All the caveats listed in this section are resolved in Cisco IOS Release 12.2(2)XB6. This section describes only severity 1 and 2 caveats and select severity 3 caveats.

Table 15 Resolved Caveats for Cisco IOS Release 12.2(2)XB6 

DDTS ID Number
Description

CSCdx07849

radius_saveident should use CSCdw51651 method to avoid write_memory

An attempt to update the startup-config file (via the EXEC "write memory" command or equivalent) may fail with the following error:

router#write memory
startup-config file open failed (Device or resource busy)

This problem can be caused by a process that is attempting to update NVRAM getting stuck for some reason. To track down the offending process, use the command "show file descriptors":

router#show file descriptors
File Descriptors:

FD Position Open PID Path
0 0 430A 157 nvram:


Now, using show process, find the process with the offending PID. If the PID belongs to a process called radius nvwrite, then this DDTS is the problem.

Workaround: Save the current running config to a temporary file in flash or on a TFTP server. Reload. Immediately after reloading, copy the saved configuration to nvram:startup-config.

CSCdx26331

SIP: Connect Timestamp missing in CallHistory when ACK is missing

Symptom: The Call History information generated by the SIP call leg does not have a valid (non-zero) duration while the POTS Call History for the same call has a non-zero duration.

Conditions: This will happen when the ACK fails to reach the TGW following an answer (200 OK response).

Workaround: There is no workaround.

CSCdx47143

Some E1 contrlrs remain down after bootup; Come up after shut/noshut

Some E1 controller ports remain down after bootup of 12.2(2)XB5 4.10.0 as5800 prefcs ios.

Workaround: Shut/no shut the E1 controller that is stuck in the down state. Consequently, the controller will come up.

CSCdx81388

Memory leak in PPP Events after stress test

Memory Leak is seen in PPP Events after stress test on Cisco AS5400 running 12.2(02)XB06 pre-fcs 5.3.0 build.

Workaround: There is no workaround.

CSCdw03288

UP324 card crash while handing over in handover-split mode

Symptom: While handing over UP324 board from one RSC to another using the redundancy hand-over mode and reloading the RSC which was handling the UP324, the CPU util of the UP324 goes upto 100% and the board crashes when its handed to the other RSC.

Conditions: This affects platforms which have redundancy hand-over mode support.

Workaround: There is no workaround.


Open Caveats—Cisco IOS Release 12.2(2)XB5

This section documents possible unexpected behavior by Cisco IOS Release 12.2(2)XB5 and describes only severity 1 and 2 caveats and select severity 3 caveats.

Table 16 Open Caveats for Cisco IOS Release 12.2(2)XB5 

DDTS ID Number
Description

CSCdu79111

TCL APP processes take too much cpu when making +7cps debicard calls.

Symptom: When system running debitcard application with bursty traffic of 15+ call per second back-to-back, IVR processes such as TCL APP take too much cpu causing a high overall cpu utilization.

Workaround: Control incoming calls to avoid bursty traffic and turn on Call Admission Control to prevent catastrophic errors at high cpu utilization.

CSCdv42872

Various problems due to IPC message cache depletion

The following Inter-Processor Communication (IPC) messages may be displayed on a Cisco AS5800 or Cisco AS5850 universal gateway when the gateway is
under a heavy load:

%IPC-3-NOBUFF: The main IPC message header cache is empty %DSIP-3-IPC_PORT: IPC
subsystem API error(nip invoke ipc send), failed to get ipc_message, Async data:Slave8

Workaround: There is no workaround.

CSCdv70676

SPE went to Bad state with incoming modem calls and 100% COT.

With modem calls and 100% COT transponder, SPEs on a Cisco AS5400 OGW would transition to BAD state one by one. Executing the clear spe command or the would reset the SPEs back to normal state but after a few more modem calls, the SPEs would come back to BAD state. Test port modem back to back also bring the SPEs back to normal state.

CSCdv80695

Tetryl DSPs get stuck in DOWNLOAD state after doing <clear spe>

Tetryl SPE's may get stuck in DOWNLOAD firmware state after running for a week with 12.2(2)XB1 ios.
SPE SPE SPE SPE Port Call SPE# Port # State Busyout Shut Crash State Type 1/06/00 0000-0005 ACTIVE 0 0 0 ______ ______ 1/06/01 0006-0011 ACTIVE 0 0 0 ______ ______ 1/06/02 0012-0017 DOWNLOAD 0 0 0 dddddd ______ 1/06/03 0018-0023 DOWNLOAD 0 0 0 dddddd ______ 1/06/04 0024-0029 DOWNLOAD 0 0 0 dddddd ______ 1/06/05 0030-0035 DOWNLOAD 0 0 0 dddddd ______

If this happens, the workaround is to do a soft reload of the Tetryl card.

CSCdv80695

Tetryl DSPs get stuck in DOWNLOAD state after doing <clear spe>

Tetryl SPE's may get stuck in DOWNLOAD firmware state after running for a week doing clear spe with active stress level traffic with Cisco IOS Release 12.2(2)XB1.

If this happens, the workaround is to do a soft reload of the Tetryl card.

CSCdw38736

spurious memory access at update_calls_agg(0x60c7e548)+0x26c

The Cisco AS5800 universal gateway has analog and digital calls. During the polling for the cpmDS1DS0UsageTable a spurious memory access is observed. There is no workaround.

CSCdw80521

RPM does not unbind dynamic template when call disconnects early
If a gateway is configured for resource-pooling with customer profile templates, a short, abnormal call may cause the next call on that modem/interface to bind to multiple profiles causing the configuration for the next call to be different than intended. A workaround which works under some circumstances (but not all) is to make sure that each customer profile template explicitly specifies every configuration item which may be different on other customer profile templates to make sure the configuration items on the intended template overrides any configuration items on other templates which may be unexpectedly bound. The workaround does not work when multiple short, abnormal calls land on the same port consecutively.

CSCdw83849

APS-B-BPX: AnxB: Lockout doesnt keep selector position.
Conditions: Force switch WS1->WS2 on AXSM/B, Lockout on BXM side.

Workaround: There is no workaround.

CSCdx01300

The router locks out when RAI raised to 85-95

Symptom: Raising RAI from low-high of 75-85 to 85-95 might cause Cisco AS5800 router to hang/lockup.

Condition : The Cisco AS5800 will stop processing calls, will not respond to CLI requests. After stopping the traffic, the Cisco AS5800 starts responding again, but will not be able to handle
normal call volume.

Workaround : There is no workaround. Box needs to be reloaded.

CSCdx03069

Memory leak on GW if AltEP present in ACF with dCSA 0.0.0.0

Memory leak on the H323 voice gateway noticed. If the Gatekeeper of the Gateway sends an Admission Confirm (ACF) message with the destination Call Signal Address (dCSA) field set to 0.0.0.0 and if the alternate Endpoint field is present in the message.

Workaround: There is no workaround.

CSCdx05186

%CSM-1-NO_CSM_CALL_INFO and traceback while teardown calls

This defect is seen on the Cisco AS5800 while doing stress testing when calls are torn down randomly. Right now there is no workaround.

CSCdx05571

Fail to originate E1/R2 calls under u-law

Cisco AS5800 fails to originate R2 calls if command-type u-law (default) is configured under voice port. A-law is working fine.

The problem appears to be specific to use 00 drive UP gateway.

CSCdx11753

Crash at get_format_from_type(): port modem startup-test

One might run into Crash at get_format_from_type() when "port modem startup-test"
is configured on the NAS. Right now there is no workaround.

CSCdx13149

Traceback at p_enqueue() in ISDN process

There might be Spurious Memory Access at p_enqueue() and csm_proc_ic2_ring() when there is negative testing conducted on connect/disconnect ethernet and rs-ds connections.

Workaround: There is no workaround.

CSCdx13190

Hearing Loud pitch (1Khz) Tone with e&m-fgb mf dnis.

Workaround: There is no workaround.

CSCdx14794

AS5800 Dosent Transmit Data On some lines with Tetryl Board

Sometimes for a modem call, Cisco AS5800 (with tetryl card and nextport modems) is not sending the data after DSR come up on the modem.The client side keep sending the PPP/LCP frames and timeout, finally disconect the call.

CSCdx16253

Incorrect DSC entry for entPhysicalDescr in entPhysicalTable

When we query the entPhysicalDescr of ENTITY-MIB, the entry for DSC shows BACKUP (BK) for both DSC's, even though one is ACTIVE and other DSC is BACKUP. This problem occurs under Redundancy-III setup and the Cisco AS5800 image is based on Cisco IOS Release 12.2(2)XB5.

Workaround: There is no workaround.

CSCdx19640

SYS-3-INTPRINT: Illegal printing attempt from interrupt level.

Error message with the below message can be seen on Cisco AS5800(running with Cisco IOS Release 12.2(2)XB) console, when the command "hw-module slot" is used to reload any of the Feature Boards.

"Illegal printing attempt from interrupt level."

This is not service or performance Impacting. Only a cosmetic issue.

Workaround: There is no workaround.

CSCdx25354

Portware 2.9.1.2 times out , Marks MICA modules BAD

Portware version 2.9.1.2 for Mica Modules may timeout initially after reload or after firmware download.

CSCdx26331

SIP: Connect Timestamp missing in CallHistory when ACK is missing.
Symptom: The Call History information generated by the SIP call leg does not have a valid (non-zero) duration while the POTS Call History for the same call has a non-zero duration.

Conditions: This will happen when the ACK fails to reach the TGW following an answer (200 OK response).

Workaround: There is no workaround.

CSCdx29835

DMM/UPC dont come up after OIR,DSIP send data fails

UPC and MICA-DMM cards might not recover after OIR is performed on these cards.

This might be service impacting.

Workaround: Use Software OIR instead using "hw-module slor x/y" command.

CSCdx31707

!CSMM_FIFO_FULL Messages seen when Modem-InOut is removed from LINE

Removing Modem InOut from the LINE config gets the Router Shelf to an unstable situation. !CSM messages might be seen as a result. Also a few Modem Modules might be marked as BAD. This might be service impacting.

CSCdx32336

%VTSP-3-DSP_TIMEOUT: DSP timeout on event 0x6:

Description Router reports intermittently the DSP error message Mar 22 16:50:02.308: %VTSP-3-DSP_TIMEOUT: DSP timeout on event 0x6: DSP ID=0x51902: DSP Disc (call mode=0) Mar 22 16:50:06.308: %VTSP-3-DSP_TIMEOUT: DSP timeout on event 0x6: DSP ID=0x51902: DSP error stats (call mode=1697895432)

Workaround: There is no workaround.

CSCdx32363

RS reloaded unexpectedly during stress/Normal Load at emt_call

Cisco AS5800 might reload unexpectedly under stress conditions when a high call volume is coming in. This might be service impacting.

Workaround: There is no workaround.

CSCdx33071

DNIS/L2F based VPDN broken for V120 calls

V120 Calls fail when VPDN is enabled for DNIS screening. This might be service impacting.

Workaround: There is no workaround.

CSCdx34549

Cisco AS5800 crashes at dec21140_rx_intre when stress with 3cp teardown WSD

Conditions: Cisco AS5800 access router crashes under stress when configured to handle multiple call types.

Workaround: There is no workaround.

CSCdx37009

Calls Fail after DSC Failover for Router Shelf Redundancy

Calls will not complete in a Router Shelf Redundancy configuation, if a loss of the active Dial Shelf Control (DSC) Card is lost. Failover will occur but modem calls will continue to fail.

CSCdx39435

CICs doesn't return to IDLE state after stress testing

While running a debit card stress test with 124 ss7 calls and 540 PRI calls, it was observed that after stopping the test the CICs doesn't return to IDLE state (remains in the OUT state).

Workaround: There is no workaround.

CSCdx42687

IOS do not send any accounting command update info

Symptom: The tacacs server does not receive any accounting command information, it receives the authorization command information only.

Conditions: System is being accessed by the line vty 0 thru 4

Workaround: Do not use a specific group name:

aaa accounting commands 0 ADMIN start-stop group tacacs+ aaa accounting commands 1 ADMIN start-stop group tacacs+ aaa accounting commands 15 ADMIN start-stop group tacacs+

instead use "default"

aaa accounting commands 0 default start-stop group tacacs+ aaa accounting commands 1 default start-stop group tacacs+ aaa accounting commands 15 default start-stop group tacacs+

CSCdx49365

Modem VPDN calls with configured from RPMS 1.1 fails

Issue: Analog VPDN calls fails when VPDN configuration is downloaded from RPMS 1.1 server for Cisco 5XXX Gateway.

Workaround: Configure VPDN on AAA or gateway.

CSCdx49620

Cisco AS5400 crashes with bus error in free function

CSCdx50282

SIP GW: Calling party name presented to PSTN has problems

When a display-name is presented in a From header of a SIP INVITE to a IOS SIP gateway, the DISPLAY IE setting in the outgoing ISDN message maynot be interoperable with dms-100 ISDN switch type.

CSCdx50498

Local RPM CLI commands for VPDN profiles stripped out at bootup

Symptom: The resource pooling VPDN CLI commands in startup config is not recognized by 5400 when it boots up.

Workaround: Manually enter that in the configuration after bootup.

CSCdx51478

Authentication failures for some users when class attribute present

On a Cisco Gateway, when a RADIUS CLASS attribute is received in the RADIUS access-accept packet, it might be that under some conditions authentication fails. This can happen even though RADIUS sends a success.

CSCin09639

Voice calls fail with call deflection


Resolved Caveats—Cisco IOS Release 12.2(2)XB5

All the caveats listed in this section are resolved in Cisco IOS Release 12.2(2)XB5. This section describes only severity 1 and 2 caveats and select severity 3 caveats.

Table 17 Resolved Caveats for Cisco IOS Release 12.2(2)XB5 

DDTS ID Number
Description

CSCdu14530

If the IP address is removed from a the PPP interface of a 7500, running Cisco IOS Release 12.1E IOS, and then the IP address is added, this change is not reflected immediately in CEF. This results in 50% packet loss until the background CEF process updates the adjacency.

Workaround:

shut / no shut the PPP interface. or

disable CEF (not an option as the 7500 is a PE router).

CSCdv08170

DS-RS go out of SYNC when analog calls are dropped on MICA & Nextport

On a fully loaded Cisco AS5800 universal gateway, "DS-RS flow control has got out of sync" messages may be displayed when analog calls are cleared using the clear spe EXEC command. This condition may impact service on the gateway.

Workaround: There is no workaround.

CSCdv38563

Client code does not add attributes 90 & 91 for the LAC Network gateway (NAS) may fail to include attributes 90 and 91 when a router hostname is used as the tunnel ID and when the tunnel ID is not included in the user profile.

Workaround: There is no workaround.

CSCdv54127

Missing Acct-Output-Packets & Acct-Input-Packets in STOP rec

The Acct-Output-Packets and Acct-Input-Packets attributes are missing in the STOP record while testing network accounting, even though they are seen in the debug output.

CSCdv54509

MALLOCFAIL:Memory allocation of 9 bytes failed from 0x60557958.

When an X.75 call is made on a E1 or PRI interface, a "SYS-3-INVMEMINT: Invalid memory action (malloc) at interrupt level" message may be displayed. This condition has no user impact. There is no workaround.

CSCdv66747

Traceback at l2tp_fixup_cached_header

Tracebacks occur with vpdn in Cisco IOS Release 12.2(02)XB, Cisco IOS Release 12.2(03)PI, & Cisco IOS Release 12.2.T.

CSCdv71454

l2tp_process_unsent_queue may cause CPUHOG

In Cisco IOS Release 12.2 T, "L2TP mgmt daemon" may cause CPUHOG if there are lots of packets in unsentQ.

CSCdw00298

E1 remains down due to remote alarm after dis/reconnecting cables

When dis- and reconnecting E1 cables on a Cisco AS5800, it might happen that an E1 controller does not return up automatically but remains down in following status:

E1 1/0/1 is down.
Applique type is Channelized E1 - balanced
Receiver has remote alarm.
alarm-trigger is not set
Framing is NO-CRC4, Line Code is HDB3, Clock Source is Line.

Possible workarounds are:
- Dis- and reconnect the E1 cable on this E1 controller again
- Configure shutdown/no shutdown on this E1 controller

CSCdw00924

MLP bundle transmit may jam when link departs bundle

On a PPP multilink bundle that has multiple links, if one of the links departs from the bundle while data is enqueued for output at the bundle interface, the output mechanism on the bundle may stall, halting any further output from that bundle. The output queue on the bundle becomes full, causing packets that are forwarded to that bundle to be dropped and the affected bundle to stop transmitting packets.

Workaround: There is no workaround.

CSCdw06038

RPM:no profile found for call-type digital

Symptom: With Resource Pooling and Resource Pooling AAA accounting configured, a customer profile may not be found for a particular DNIS group.

Conditions: The gateway may have a problem with incoming calls finding the customer profile depending on the order, size and value of the dnis entered; results may vary depending on whether the DNIS is manually entered or whether the wavl is set up from reload via the start-up config.

Workaround: There is no workaround.

CSCdw09840

Spe are stuck in REC PEND after maintenance period

After using the command spe download maintenance time, some spe doesn't recover anymore and get stuck REC PEND state.

Workaround: Clear the spe or shut/no shut the specific ports.

CSCdw39083

Calls being disconnected by gateway with cause code 47(resource una)

When running test calls in a ThunderVoice environment a small percentage of the calls are being rejected by the originating gateway with cause code 47 (resource unavailable, unspecified).

Workaround: There is no workaround.

CSCdw45584

Cisco-AV pair lcp:send-secret=cisco not supported in XB

VPDN authorization fails when "lcp:send-secret=xxxx" is sent in the access accept packet from RADIUS.

CSCdw55476

ISDN Channels OOS requiring shut/no shut to restore

In the NAS-SC2200 environment, when microinterruptions occur on the E1 controllers, the B channels can get stuck in the "out of service"` state. No calls can be made on those B channels.

Workaround: Do a "shut; no shut" on the controller(s).

CSCdw60334

Spurious memory access at 0x60840840 reading 0xA0, xcsp_ppp_ev...()

Following spurious memory access messages would be seen with Cisco AS5800 12.2(2)XB3
IOS with incoming analog digital isdn calls.

Jan 30 14:57:12.591 PST: %ALIGN-3-TRACE: -Traceback= 60840840 607C25D4 607B6DAC 607E8D48 607E811C 607E8260 607E8E84 6055E0F4 Jan 30 14:57:12.591 PST: %ALIGN-3-TRACE: -Traceback= 60840844 607C25D4 607B6DAC 607E8D48 607E811C 607E8260 607E8E84 6055E0F4 Jan 30 14:57:12.591 PST: %ALIGN-3-TRACE: -Traceback= 6084084C 607C25D4 607B6DAC 607E8D48 607E811C 607E8260 607E8E84 6055E0F4 Jan 30 14:57:12.591 PST: %ALIGN-3-TRACE: -Traceback= 60840850 607C25D4 607B6DAC 607E8D48 607E811C 607E8260 607E8E84 6055E0F4 Jan 30 14:57:12.591 PST: %ALIGN-3-TRACE: -Traceback= 60840858 607C25D4 607B6DAC 607E8D48 607E811C 607E8260 607E8E84 6055E0F4 Jan 30 14:57:12.591 PST: %ALIGN-3-TRACE: -Traceback= 60840844 607C25D4 607C69AC 607B6540 607B30C4 607B34C0 607E811C 607E8260 Jan 30 14:57:12.591 PST: %ALIGN-3-TRACE: -Traceback= 60840850 607C25D4 607C69AC 607B6540 607B30C4 607B34C0 607E811C 607E8260

The problem is not service impacting, but it will cause performance issues.

The following syslog message will also be seen with each call:

Jan 30 20:30:14.547 PST: XCSP:Slot 2 not initialized

CSCdw62064

IKE Keepalives being dropped with MLPPP fragmentation

On 7200 running Cisco IOS Release 12.2.6, it is seen that with T1 links combined in a Multilink PPP bundle, and MLPPP fragmentation enabled; ISAKMP keepalives are not being received by the box, even though the remote peer is sending out the keepalive messages. As a result each end thinks its peer is dead and deletes the IKE & IPSEC SA's. They then re-negotiate IKE and IPSEC and create new SA's. As a result, IKE and IPSEC are re-negotiated at each IKE keepalive interval and there is some traffic drop during this re-negotiation phase.

Workaround:

Disable hardware crypto acceleration. With software crypto, this problem is not seen.

Disable MLPPP fragmentation. Without fragmentation, the IKE keepalives are received by the peers (even with hardware crypto)

CSCdw68066

Memory leak in PPP Hooks with vpdn authen-before-forward

A Cisco router that is configured as a Layer 2 Tunneling Protocol (L2TP) access concentrator (LAC) may not free memory properly if the vpdn authen-before-forward VPDN group mode command is configured.

Workaround: There is no workaround.

CSCdw68757

Caller hear second dial-tones CHOM noise from Nortel PBX.

Caller on original GW of CAS hear the second dial-tone CHOM from the far end router which connected to Nortel PBX. This is only for CAS case.

Workaround: There is no workaround.

CSCdw71269

Lot of SESSION ABORTs & NAKs during stress test causes 100% CPU utl

After about 24+ hours of uptime, the Cisco AS5850 NAS experiences some Session Abort/Run Time Errors. This cause a high number of NAKs to be generated resulting in high CPU utilization & a lot of VTSP timeout messages.

Workaround: There is no workaround.

CSCdw80687

ip tcp compression-header passive is always compressing ppp traffic

Symptom: Packets are process switched on an interface with fast switching configured. This can result in high CPU usage.

Conditions: Header-compression must be configured, but only on one side. For example, in a dial-in situation, where header-compression is configured on the central switch, but not on the box that is dialling in. Also, the interface must not support FAST switched header-compression, e.g. most dial-in interfaces are currently not supported.

Workaround: Remove header-compression from the configuration.

Note If header-compression is configured on both sides of a link, and the interface does not support fast-switched header-compression, then process switching is normal and required for successful operation of the header-compression feature.

CSCdw85178

OJ:VSA incorrectly billing ip hops

Genuity is not able to bill multiple customers off of one proxy.

Workaround: There is no workaround.

CSCdw86280

Bus error at emt_call() on RS, triggered by DSC reload

Cisco AS5800 running Cisco IOS Release 12.2(2)XB5 ios would experience a bus error crash when DSC is reloaded.

CSCdw89455

PPP authen failure with fourth method

All PPP authentication methods will not work with MSCHAP V2.

CSCdw91279

L2TP ZLB ACK not processed correctly (regress CSCdk57040)

A Cisco router that is running Cisco IOS Release 12.2(5.7)T or a later release and that is acting as a Layer 2 Tunneling Protocol (L2TP) access concentrator (LAC) or L2TP network server (LNS) may fail to process valid L2TP Zero-Length Body Acknowledgement (ZLB ACK) packets. This behavior may cause sessions and tunnels to drop.

Workaround: There is no workaround.

CSCdw91760

Dynamic IP pool download from RADIUS server fails for dig mlp calls

Dynamic IP pool download for digital mlp calls is broken in Cisco IOS Release 12.2(2)XB5. This feature works fine in Cisco IOS Release 12.2(2)XB4.

CSCdw95464

Bus Error Crash: appp_tty_shutdown():making analog calls

Cisco AS5800 running Cisco IOS Release 12.2(02)XB05 would experience a Bus Error Crash while running Analog Calls.

CSCdx02102

Memory corruption with MPPE when MTU exceeds 8K

A Cisco router may experience memory corruption when configured with software encryption (MPPE) if the MTU size is greater than 8K (and if there are actually packets of length greater than 8K).

Workaround: Configure MTU less than 8K when doing software encryption (MPPE).

CSCdx05704

MSCB won't propose the skip CB option to peer with dialer profiles

When a user dials in, requests MSCB and is bound to a dialer profile, after authentication (problem won't happen if the profile is bound before PPP starts) then IOS does not propose the option to skip callback during CBCP even if we are configured for it (ppp callback accept and user has empty callback dial string).

If the user opts to skip the callback anyway, we will drop the call because we did not propose that option, which is correct behaviour but has only been enforced since CSCdu55093, which is why this bug has been relatively hidden up until recently.

CSCdx07065

Software forced Crash at rm_author_req-free(): reload RS

This defect is seen on the Cisco AS5800 immediately after a reload. Right now there is no workaround.

CSCdx09410

Local RPM CLI commands for VPDN profiles stripped out at bootup

Symptom: A CLI command in startup config is not recognized by Cisco AS5800 when it boots up.

Workaround: Workaround is to manually enter that in the config after bootup.

CSCdx11607

Enable pre-auth breaks digital calls

AAA pre-authentication causes digital calls to break, because resource allocation fails.

Workaround: There is no workaround.

CSCdx14245

DNIS based PREAUTH is broken for mlp & v120 calls. Disconnect by RM

Incoming digital mlp calls will be rejected by Cisco IOS Release 12.2(2)XB5 when DNIS pre-authentication is turned on.

CSCdx16376

Router Reloads Due to Bus Error(csm_vtsp_digit_ready)

A Cisco Router running an IOS image based off Cisco IOS Release 12.2(2)XB2 may reload due to bus error. The cause for the reload is unknown.The following snip can be seen on the show version command:

System returned to ROM by bus error at PC 0xXXXXXXXX, address 0xXXXXXXX at 23:48:02 UTC Wed Mar 6 2002

XXXXXXXX represents the PC value and the address that caused the reload.

CSCdx18198

2 spur mem accesses per v120 call at move_cursor_to_next_attr()

Following spurious memory access message will be recorded during v120 call
setup:

Mar 28 14:26:20.848 PST: %ALIGN-3-SPURIOUS: Spurious memory access made at 0x6049D1D4 reading 0x8 Mar 28 14:26:20.852 PST: %ALIGN-3-TRACE: -Traceback= 6049D1D4 6049FD9C 607EE578 607EDA4C 604F2C34 605041D4 605729FC 605729E8 Mar 28 14:26:20.852 PST: %ALIGN-3-TRACE: -Traceback= 6049D1E8 6049FD9C 607EE578 607EDA4C 604F2C34 605041D4 605729FC 605729E8

The defect is not service impacting.

CSCdx21469

Idle timer is broken for dig mlp calls

Idle timer will not work with the latest Cisco IOS Release 12.2(2)XB5.

Workaround: There is no workaround.

CSCdx21563

Incorrect disconnect cause due to session timeout in RADIUS stop rec

Session timeout works well with Cisco IOS Release 12.2(2)XB5 pre-fcs ios but the mlppp call disconnect cause due to session timeout will not be reflected in RADIUS stop record. The stop record will reflect the disconnect cause as PPP LCP Close.

Workaround: There is no workaround.

CSCdx22275

Two RADIUS accounting stop records are sent for 1-b chan v120 call

With Cisco IOS Release 12.2(2)XB5 4.5.0 prefcs ios, two RADIUS accounting stop records will be sent to the RADIUS server for a 1-b chan v120 call.

Workaround: There is no workaround.

CSCdx22886

SGBP functionality broken

SGBP forwarding does not work if VPDN is disabled.

Workaround: A temporary workaround for this problem is to enable VPDN (issue the command 'vpdn enable') and then disable it immediately (issue 'no vpdn enable') on all the SGBP stack group members. This allocates the resources required to do SGBP, and at the same time does not require VPDN to be kept enabled.

CSCdx23322

-ve presession-octets in RADIUS accounting stop records of V120 call

AAA accounting stop record will contain -ve values for a v120 call with Cisco IOS Release 12.2(2)XB5 Apr3rd pre-fcs ios. A199+G198dup

Workaround: There is no workaround.

CSCdx23341

RADIUS AAA stop record for hairpinned async vpdn call has -ve values

With Cisco IOS Release 12.2(2)XB5, RADIUS AAA accounting stop records may contain -ve values for async vpdn calls.

Workaround: There is no workaround.

CSCdx24115

RADIUS acc record has -ve presession bytes when v120 session-timeout

-ve presession bytes will be seen in RADIUS aaa accounting stop record when a v120 call disconnects due to any reason.

CSCdx26331

SIP: Connect Timestamp missing in CallHistory when ACK is missing

Symptom: The Call History information generated by the SIP call leg does not have a valid (non-zero) duration while the POTS Call History for the same call has a non-zero duration.

Conditions: This will happen when the ACK fails to reach the TGW following an answer (200 OK response).

Workaround: There is no workaround.

CSCdx34549

5800 crashes at dec21140_rx_intre when stress with 3cp teardown WSD

Conditions: Cisco AS5800 access router crashes under stress when configured to handle multiple call types.

Workaround: There is no workaround.

CSCdx40546

No ANI Infomation for T37 offramp fax

For T.37 offramp fax, the ANI information is currently available only from the message envelope of the email. But in the case that the mail has to be bounced (such as invalid fax machine number), the mail cannot be bounced back to the correct account. The call cannot be billed in this case.

CSCin03065

New L2TP Tunnel created with existing Tunnel to same LNS.

When an attempt is made to create an additional session that has similar tunnel parameters that are defined by a RADIUS profile (for the same domain, the same user, or a different user), instead of creating a session under the existing tunnel, a new tunnel and a session are created. This condition is observed in Cisco IOS Release 12.2(7.4)T and occurs if the tunnel parameters are defined by RADIUS without either of the following definitions:

Cisco-Avpair vpdn:tunnel-id = "xyz"

Tunnel-Client-Auth-ID = "xyz"

Workaround: Define one of the following definitions under a RADIUS profile when tunnel parameters are defined:

Cisco-Avpair vpdn:tunnel-id = "xyz"

Tunnel-Client-Auth-ID = "xyz"

CSCin06313

RM/AUTH: Process (22) failed to register to VPDN message while boot

Cisco AS5850 pops out the following error message after boot up:

00:00:38: RM/AUTH: Process (22) failed to register to VPDN

This message is seen with c5850-p9-mz-v122_2_xb_throttle_flo_t.0.4.0 image.

Workaround: There is no workaround.

CSCuk32311

PPP: Only allow punt adjacencies to be installed until IPCP is open

When Cisco Express Forwarding (CEF) is enabled, adjacencies are erroneously added for sessions that have been forwarded using a tunnelling protocol such as L2TP or PPPoE. Adjacencies should only be added for sessions that terminate on the router, and only after the IP Control Protocl (IPCP) has been negotiated.

Workaround: There is no workaround.

CSCuk33327

RADIUS fail during EAP should trigger LCP restart

After RADIUS failover, during EAP, the NAS would try to failover to a new RADIUS server. However, this is forbidden midway through authentication. As such, the NAS was required to restart the authentication process from scratch and allow the user another attempt to authenticate.


Open Caveats—Cisco IOS Release 12.2(2)XB4

All the caveats listed in this section are open in Cisco IOS Release 12.2(2)XB4. This section describes only severity 1 and 2 caveats and select severity 3 caveats

.

Table 18 Open Caveats for Cisco IOS Release 12.2(2)XB4

DDTS ID Number
Description

CSCdu69988

Some modems may pause indefinitely in the VDEV state (0x00002000) and stop accepting calls. The modems become locked in the VDEV state (0x00002400) if an attempt is made to clear them. This condition affects only the Cisco AS5300 universal gateway.

Workaround: There is no workaround.

CSCdv38563

Network gateway (NAS) may fail to include attributes 90 and 91 when a router hostname is used as the tunnel ID and when the tunnel ID is not included in the user profile.

Workaround: There is no workaround.

CSCdw34586

Attribute 5 is included in the access-request twice and displayed with a wrong value. The access-accept has attribut 7 and 13 also missing.

CSCdw61066

MICA modules might go BAD and then recover on its own, under normal conditions. This might be service impacting.

CSCin00405

No RADIUS accounting start or stop record is sent by the NAS when "ppp multilink" and "aaa accounting delay-start" are configured.

Workaround: Remove one of these two commands.


Resolved Caveats—Cisco IOS Release 12.2(2)XB4

All the caveats listed in this section are resolved in Cisco IOS Release 12.2(2)XB4. This section describes only severity 1 and 2 caveats and select severity 3 caveats.

Table 19 Resolved Caveats for Cisco IOS Release 12.2(2)XB4 

DDTS ID Number
Description

CSCdr47232

Set operation is not implemented for a few dsx1 specific MIB objects like dsx1LineType, dsx1LineCoding etc.

CSCdr85436

Description: This command can be used in the global config mode, to enable sending RADIUS attribute 32 (NAS-Identifier) in the accounting request. By default fully qualified domain name (FQDN) is sent in the attribute when the format is not specified.

Syntax:

[no] radius-server attribute 32 include-in-accounting-req {format <A string that may have %i, %h or %d.>}
%i = IP address
%h = Hostname
%d = Domain name

FQDN is sent by default if the format string is not configured.

Examples:

manly(config)#radius-server attribute 32 include-in-accounting-req format cisco %h.%d %i

Following string will be sent in NAS-identifier as a part of accounting record.

cisco manly.nlab.cisco.com 10.0.1.67

CSCdr93141

The user-maxlinks feature (see http://www.cisco.com/univercd/cc/td/doc/product/software/ios120/
120newft/120t/120t5/maxlink.htm) does not work when configured on a VPDN LNS/HGW.

CSCdt63321

An IP route entry may fail to be updated properly when one-step and two-step translations are performed using the Serial Line Internet Protocol (SLIP).

Workaround: There is no workaround.

CSCdu19432

Attribute Acct-Session-Time [46] in EXEC Acct. Stop Record is zero.

Workaround: There is no workaround.

CSCdu35843

IP access lists are not installed when they are received from a RADIUS server. This condition is observed in Cisco IOS Release 12.2(1.2)PI.

CSCdu36862

A system accounting record needs to be sent when a RADIUS server is added or deleted.

This will be committed in latest 12.2 branch and will also be committed in latest 6400 branch.

CSCdu40402

On Cisco AS5400, Cisco AS5800, and Cisco AS5850 universal gateways running Cisco IOS Release 12.2XB, executing the command show tdm mapping will not show resource s that are used for CAS calls.

Workaround: There is no workaround.

CSCdu40615

Some clients may fail to successfully complete IP Control Protocol (IPCP) negotiations when thousands of PPP sessions are simultaneously reestablished, as is the case when an interface with many links is recycled. All Layer 2 Tunneling Protocol (L2TP) sessions are established, but some client virtual access interfaces may not get a negotiated IP address. The missing IP address results in lost IP connectivity on that link.

Workaround: There is no workaround.

CSCdu43689

Currently, the Per-User Request buffer is limited to 600 bytes. If the user profile has more than 600 bytes of configuration information, the Per-User attributes are not processed, which results in rejecting the user.

Workaround: There is no workaround.

CSCdu65125

Cisco AS5800 (NAS) does not negotiate multilink ppp over L2F tunnel.

CSCdu64847

CISCO-AAA-SESSION-MIB user disconnect feature doesn't work for vpdn connections on the LNS.

CSCdu67010

Some TACACS+ attribute string names and attribute string values have changed slightly, e.g. "nas_rx_speed" is now "nas-rx-speed". This may cause problems for backend accounting applications trying to process records or authorization failures.

CSCdu74728

No accounting records are generated for outbound Telnet sessions after connection accounting is configured.

Workaround: There is no workaround.

CSCdu84692

When using Cisco IOS Release 12.2(2.x) and Cisco IOS Release 12.2(3.x)PI code, local VPDN authorization does not failover to the next method in the method list if the domain/dnis profile is not found. The workaround is to only use RADIUS/TACACS+ vpdn authorization.

CSCdu86243

The RADIUS attributes Ascend-Client-Primary-DNS and Ascend-Client-Secondary-DNS do not work in Cisco IOS Release 12.2(3.4)T or later. The Cisco-AVPair ip:dns-server also does not work.

Workaround: There is no workaround.

CSCdv01412

Conditions under which the problem occurs:

FXS FastEthernet FXS(LoopBack)
[Pots A]--------[1750_r1]--------|-------[1750_r2]

dial-peer voice 1 voip dial-peer voice 2 voip
destination-pattern 300 destination-pattern 300
session target ipv4:100.0.0.2 session target loopback:rtp

When A calls 300, no voice loopback occurs.

Symptoms of the problem: silent.

Workaround: There is no workaround.

CSCdv01555

Spurious access may been seen when TACACS+ is enabled in Cisco IOS Release 12.2(3.4)T or later.

Workaround: There is no workaround.

CSCdv02732

A router that is running Cisco IOS Release 12.2(3.4) T or a later release may reload unexpectedly after the Terminal Access Controller Access Control System (TACACS+) command accounting is enabled and a config net privileged EXEC command is executed. There is no workaround.

CSCdv03076

A Cisco router running Cisco IOS Release 12.2(3.4)T or later will not process Ascend RADIUS server attributes even if "non-standard" is part of the RADIUS-server host configuration statement if the RADIUS-server is referenced through a aaa server group.

Workaround: Do not use a server-group and use group RADIUS instead.

CSCdv03689

If a Point to Point Protocol (PPP) Multilink bundle interface goes down while data is flowing through it, a Cisco router may reload.

Workaround: There is no workaround.

CSCdv04999

The username, accounting record type, and service attributes in the command accounting record is do not have appropriate value.

Workaround: There is no workaround.

CSCdv13634

AAA Accounting is not done for the additional links added to Multilink PPP bundle when "aaa accounting delay-start" is configured.

Workaround: There is no workaround.

CSCdv15409

Symptom: Router throughput decreases as memory consumption increases.

Conditions: This happens when the customer is using RADIUS as an authentication protocol

Analysis: A memory leak was found when using RADIUS. For each session a small amount of memory ~40 bytes gets leaked. This will cause the box to lock-up after thousands of sessions depending on the amount of available memory.

Workaround: There is no workaround.

CSCdv19031

Currently with RADIUS debugging turned on customers see a lot of debugs describing attributes in the packets sent and received. In order to reduce the amount of spewed out on the console a new option of 'brief' needs to be added the 'debug radius' command. This option will only indicate I/O transactions with some packet header information. Customers not turning on debugging or, not doing RADIUS will not see this problem.

CSCdv19928

When the Idle-Timeout attribute is received from RADIUS on an asynchronous interface, a vaccess interface is created and the timeout is not applied directly to the asynchronous interface. The Idle-Timeout attribute still works. The only side effect is that there is an extra vaccess created that is bound to the asynchronous interface.

Workaround: There is no workaround.

CSCdv20977

Incoming Multilink Point-to-Point Protocol (MLP) packets from an ATM interface are getting process switched when a virtual template is used for the MLP bundle configuration.

CSCdv22728

During a Exec-virtual private dialup network (Exec-VPDN) shell-based login, a call is torn down if a user attempts to get authenticated by Network Access Solutions (NAS) before a PPP session is established.

Workaround: There is no workaround.

CSCdv26709

Certain values for Ascend-Disconnect-Cause and Ascend-Connect-Progress are recorded inaccurately in Stop messages. This is mainly observed in 122T train.

This problem is observed with PPP sessions when using RADIUS Accounting.

Workaround: There is no workaround.

CSCdv29468

If a PPP client does not authenticate after agreeing to do so during LCP negotiation, the PPP session will continue to stay open in this limbo state until the client disconnects the session.

CSCdv33270

Under certain conditions, resources may be associated with a virtual private dialup network (VPDN) group even when there are no active calls.

Workaround: There is no workaround.

CSCdv33313

When network accounting is performed for PPP over ATM (PPPoA) sessions, RADIUS "start" or "stop" accounting records may occasionally fail to be sent. There is no workaround.

Under certain conditions on a LAC, if the session is a VPDN forwarded session and the connection to the LAC is a dedicated serial line, memory can be leaked because AAA misses the stop record, so it never cleans up the AAA data for the session. This will happen if the connection continuously tries to renegotiate then attempt forwarding, which never succeeds. Eventually, the client sends a TERMREQ which restarts the session, but AAA does not get a NET STOP event so memory is leaked.

CSCdv34768

A Cisco router running IOS may show the following traceback when using "local-case" authentication:

00:05:16: %AAA-3-BADMETHOD: Cannot process authentication method 2160756888
-Process= "AAA Server", ipl= 0, pid= 26
-Traceback= 8016F170 8016A6C8 8016AED0 8016B048 8019A94C

Workaround: There is no workaround.

CSCdv35939

Modems might be marked as BAD as a result of Port-Modem-Startup Test.

Workaround: Disable Port-Modem-Startup test and reboot the Cisco AS5800 RS.

CSCdv40729

In a plain bri-pri (Peer - NAS) scenario, when a call is disconnected with the command 'clear in serial0:23' on the NAS, the Ascend-Disconnect-Cause value generated is '0' (No-Reason).

When the call is brought down by clearing the interface on the peer, it is given a value(63). If brought down by doing 'shutdown' on peer/NAS value 11 is generated. The problem occurs only with by doing clear interface on the NAS.

CSCdv40116

Reverse-access Authorization fails if the method used is RADIUS. RADIUS mandatory attribute "port" is not properly obtained causing this authorization failure.

Workaround: There is no workaround.

CSCdv41871

Ping fails when non-mlppp call is up on B-channel previously used to terminate mlppp call.

CSCdv43136

We may see some unexpected debug information during call suspend. Those debug information doesn't cause any side effect beside displaying unexpected debug information.

CSCdv43856

aaa attr debug does not show the tag added. This is seen in Cisco IOS Release 12.2(4.2)PI. This is just a problem in debug and will not affect any other functionality.

CSCdv53233

The console of a Cisco AS5800 router shelf may display several No active RADIUS servers found messages followed by RADIUS server is responding again (previously dead) messages when the server is working normally and authenticating users. This condition does not impact service.

Workaround: Remove the radius-server deadtime minutes global configuration command from the router.

CSCdv54349

When running Cisco IOS Release 12.2(5.2)T and later IOS images, you may be unable to do local AAA authentication.

Workaround: There is no workaround. Either do AAA to a remote server or downgrade to an earlier release of code.

CSCdv62424

A port that has been marked as BAD by system processing engine (SPE) modem recovery after a call failure cannot be recovered using the clear spe EXEC command. Calls cannot be placed to the port.

Workaround: Issue the clear port EXEC command.

CSCdv62649

The command ip tacacs source-interface doesn't work properly. If configured to use loopback interface for tacacs packets, router may still use interface address.

CSCdv64668

The first PAP authentication after a PPP renegotiation triggered by a CONFREQ from the client will fail even though the RADIUS/TACACS+ server returns a success.

Workaround: There is no workaround.

CSCdv67009

The following error message may be seen on a Cisco voice gateway running the Session Initiation Protocol (SIP):

Nov 24 20:24:12: %SIP-3-BADPAIR: Unexpected event 14 (SIPSPI_EV_CC_CALL_CONNECT) in state 8 (STATE_DISCONNECTING) substate 0 (SUBSTATE_NONE)
-Traceback= 60DAD08C 60DAD7AC 6040ACD4 6040ACC0.

This indicates that the call was cancelled while it was in the process of being brought up.

This message can be safely ignored.

CSCdv76649

When the customer tries to use ^C to abort the copy operation when he prompted for confirmation, he can't break out of the copy process.

CSCdv77234

On Cisco dial access concentrator routers, L2TP tunnels do not come up when the resource pooling feature is enabled.

Workaround: There is no workaround.

CSCdv78693

Spurious memory access messages appear on gatekeepers when an URQ without a call signal address in it is sent to gateway.

Workaround: There is no workaround.

CSCdv79210

A Cisco router gradually looses memory when Media Gateway Control Protocol (MGCP) calls are originated on the router.

Workaround: There is no workaround.

CSCdv80016

Symptom: After the OIR of DMM or HMM cards, some modems may become stuck in Download state.

Conditions: This seems to happen if the OIR occurs shortly after a reload of the router.

Workaround: Define spe firmware locations in config mode after the OIR event to clear the SPEs.

CSCdv80902

PPP negotiation fails when you use digital PPP with dialer profiles and the serial interface on the Cisco AS5800 is reset (i.e., execute a shut / no shut on the serial interface 1/5/1:15).

This problem only appears when the serial interface is reset.

Workaround: There is no workaround.

CSCdv83040

When using Ascend RADIUS attribute 242, IP protocols of 50 and 51 will not be accepted. This will cause users with these IPsec protocols set in their profile to be disconnected.

CSCdv83402

A PPPoE/PPPoA aggregation router may unexpectedly reload when many PPP events happen in a short amount of time. The router will display a STACKLOW message before reloading.

CSCdv87754

Symptom: A Cisco AS5850 Route Switch Controller incorrectly attempts to repeatedly netboot a Cisco IOS image if it cannot find the specified boot system image on its compact flash. The system interprets the full path of the configured boot image that failed as the image it should netboot.

Messages similar to the following are observed:

Sleeping for 2 secs before next netboot attempt
%SYS-6-READ_BOOTFILE_FAIL: disk0:c5850-p9-mz File boot failed -- File not
accessible.

The correct behavior for a bootloader if it cannot find any specified boot images at reload time is to fall back and request the system to run the first image it can find off disk0: or bootflash:

Conditions: Cisco AS5850 Route Switch Controllers with Cisco IOS 12.2(2)XB1 or Cisco IOS 12.2(2)XB2 bootloaders may experience this problem at reload time if the boot system image configuration points to a file on disk0: that does not exist.

Workaround: Ensure that the boot system image configuration points to an existing and valid image on disk0:, provide additional correct boot image locations in the configuration, or use a bootloader of version Cisco IOS 12.1(5)XV3.

CSCdv88723

A memory leak may occur for Signaling System 7 (SS7) Continuity Test (COT) transponder calls at the egress gateway during stress testing. This is a voice-only system that is handling interactive voice response (IVR) calls.

Workaround: There is no workaround.

CSCdv88831

Symptom: Low Call Success Rate on Cisco AS5800 accompanied by premature disconnects.

Conditions: Cisco AS5800 Voice Gateway running Cisco IOS Release 12.1(5)XM6 with IVR calls. This symptom is seen even with the Cisco IOS Release 12.2(2)XB2 image.

Workaround: There is no workaround.

CSCdw00019

Although SGBP tunnels will still be up, SGBP bidding itself might stop working after a router has been up for sometime. This problem only occurs if two routers in the stack group receive two links of a bundle at the same time.

Workaround: Removing, and reapplying the SGBP config was sufficient to get things working again.

CSCdw01330

When an IPC324 dial feature card (DFC) is inserted and removed on an active Cisco AS5800 universal gateway or when the Service Processing Element (SPE) is reinitialized using the clear spe EXEC command, some SPEs may become stuck in the "download" state.

Workaround: There is no workaround.

CSCdw01642

A Cisco AS5800 universal gateway that is running Cisco IOS Release 12.2 may be restarted by a bus error at PC 0x603D2EC4, address 0xC. There is no workaround.

After this fix, the counters on the Virtual-Access interface could show wrong values when IP CEF is enabled and used for the L2TP sessions, on high end routers. Please ensure that CSCdv57640 is also present in the image if this is an issue.

CSCdw01726

A Simple Network Management Protocol version 3 (SNMPv3) user is created using message digest 5 (MD5) authentication using the following commands:

snmp group groupy v3 auth

snmp user abcdefghij groupy v3 auth md5 abcdefghij

An SNMP walk is performed, the configuration is saved, and the router is reloaded.

newhope:~/src/wccp2# snmpwalk -v 3 -u abcdefghij -A abcdefghij -a MD5 -l
AuthNoPriv 194.12.224.11

It is working and a debug snmp header shows this:

Incoming SNMP packet
: v3 packet security model: v3 security level: auth
username: abcdefghij

A second SNMP walk is performed:

newhope:~/src/wccp2# snmpwalk -v 3 -u abcdefghij -A abcdefghij -a MD5 -l
AuthNoPriv 194.12.224.11

After the second SNMP walk is performed, the command does not return any output and the debug snmp headers show this:

Incoming SNMP packet
: v3 packet security model: v3 security level: noauth
: username: abcdefghij

Workaround: There is no workaround.

CSCdw02367

Incoming E1-R2 calls will fail on Cisco AS5800 running 122-2.XB1 version, with UP324 card connected.

Workaround: There is no workaround.

CSCdw02945

Symptom: Incoming calls may fail to create a virtual profile even though the router is configured for this.

Conditions: This problem may occur in a dial up environment where a virtual profile virtual template is defined but where no AAA authorization has been enabled This issue only occurs in Cisco IOS Release 12.2 T.

Workaround: A workaround is to configure AAA authorization e.g., aaa authorization network default local

CSCdw06322

The following error message may be seen on a Cisco voice gateway running the Session Initiation Protocol (SIP):

Nov 24 20:24:12: %SIP-3-BADPAIR: Unexpected event 14 (SIPSPI_EV_CC_CALL_CONNECT) in state 8 (STATE_DISCONNECTING) substate 0 (SUBSTATE_NONE)
-Traceback= 60DAD08C 60DAD7AC 6040ACD4 6040ACC0.

This indicates that the call was canceled while it was in the process of being brought up.

This message can be safely ignored.

CSCdw09542

Before this fix, per-user authorization required a service type of Outbound in the RADIUS profile.

CSCdw11765

PPP Link Control Protocol (LCP) is not accepting sent CONFACK negotiated on a asynchronous interface for a virtual profile.

Workaround: There is no workaround.

CSCdw13432

When the called party is busy in a two-stage call scenario, the calling party may not hear a busy tone and the call terminates immediately. This behavior is observed with Cisco IOS Release 12.2(2)XB, Release 12.2(7), and some earlier Cisco IOS Release 12.2 releases.

Workaround: There is no workaround.

CSCdw18785

When a 302 redirect is received after a 18x with a COntact header the outgoing INVITE will have the request uri of the Contact in the 18x. It should use the Contact of the 302.

Workaround: Disable rel1xx on the router.

CSCdw22072

In Cisco IOS Release 12.2(5.7)T, the virtual-profile if-needed global configuration command that is used to disable a virtual access interface for modem calls does not work.

Workaround: There is no workaround.

CSCdw23836

When a 18x is received which was sent reliably, a PRACK needs to be sent. Subsequent 18x's received that match the previous one's call leg do not receive a PRACK. A workaround is to disable reliable provisional responses.

CSCdw25746

Symptom: Cisco Voice Gateways may experience a reload especially when running high levels of traffic.

Conditions: This problem may be experienced in Cisco IOS Release 12.2(2)XB2 and Cisco IOS Release 12.2 mainline releases.

Workaround: There is no workaround.

CSCdw28786

When the customer tries to use ^C to abort the copy operation when he prompted for confirmation, he can't break out of the copy process.

CSCdw30994

When downloading IP pools from a AAA server, there is no way to define a non-contiguous range of addresses using multiple statements like this:

"ip:pool-def#1=aol-pool 192.168.232.0 192.168.237.255",
"ip:pool-def#2=aol-pool 192.168.238.1 192.168.238.160"

When those statements are applied, the second pool-def overwrites the first one. Defining the pools on the command line yields the expected result. This only happens in Cisco IOS Release 12.2(2)XB ED release train. Cisco IOS Release 12.1/Cisco IOS Release 12.2 does not exhibit this behavior.

CSCdw32067

It's noticed that when enabling RPM/RPMS, after some time of running, the Cisco AS5800 with Cisco IOS Release 12.1(11) will show modems in use while there are no active users connected.

CSCdw35046

A Cisco router may reload when proxied RADIUS is used for authentication and accounting.

Workaround: There is no workaround.

CSCdw35930

The command aaa authentication attempts login <n> appears in the configuration if the command tacacs-server attempts <n> is present in the configuration. Changes to either command will be reflected in the other. Also, the number of attempts granted is actually one less than the number configured. The workaround is to configure one more attempt than the number you actually want.

CSCdw37055

A Cisco AS5800 universal gateway that is used as a voice gateway may display an assertion failed error message when a voice call is received.

Workaround: There is no workaround.

CSCdw43862

For some devices that are not conforming to V.110 async to sync padding requirements, this cli command allow the users to disable the padding.

CSCdw47450

CPC tone is not being generated for a CLI (Caller Line identification) analog call terminating on a Cisco AS5800. The Information element in ISDN signaling is being ignored by the Cisco AS5800. This could be the probable cause.

Workaround: There is no workaround.

CSCdw46065

A Cisco router that is used as a gateway may reload if one of multiple record routes that are received on the gateway is invalid.

Workaround: There is no workaround.

CSCdw51491

When using preauth and the 'autocommand' feature, some PPP calls may fail to come up.

CSCdw53243

In a Cisco Signaling System 7 (SS7) Interconnect for Voice Gateways solution, if a Cisco AS5400 universal access gateway receives an incoming time-division multiplexing (TDM) call (NI-2, PRI, channel-associated signaling [CAS]) with a called number that does not match a configured dial-peer, the call will be connected to a modem, and a modem tone will be played back to the calling party. This is normal behavior, however there is no configurable option for such to be rejected instead of being treated as a modem call.

CSCdw53071

If a second call is made after the first call is completely disconnected (by hanging up the phone instead of using the flash feature to switch between two calls), the second call may fail.

Workaround: There is no workaround.

CSCdw58272

Mica Modems might be marked BAD after Cisco AS5800 has been running for more then 10 hours under stress conditions.

Workaround: There is no workaround.

CSCdw58677

Cisco AS5800 may crash with the bus error exception when a Siemens IP Phone tries to redirect the call.

Workaround: There is no workaround.

CSCdw60334

Following spurious memory access messages would be seen with Cisco AS5800 running Cisco IOS Release 12.2(2)XB3 with incoming analog digital isdn calls.

Jan 30 14:57:12.591 PST: %ALIGN-3-TRACE: -Traceback= 60840840 607C25D4 607B6DAC 607E8D48 607E811C 607E8260 607E8E84 6055E0F4
Jan 30 14:57:12.591 PST: %ALIGN-3-TRACE: -Traceback= 60840844 607C25D4 607B6DAC 607E8D48 607E811C 607E8260 607E8E84 6055E0F4
Jan 30 14:57:12.591 PST: %ALIGN-3-TRACE: -Traceback= 6084084C 607C25D4 607B6DAC 607E8D48 607E811C 607E8260 607E8E84 6055E0F4
Jan 30 14:57:12.591 PST: %ALIGN-3-TRACE: -Traceback= 60840850 607C25D4 607B6DAC 607E8D48 607E811C 607E8260 607E8E84 6055E0F4
Jan 30 14:57:12.591 PST: %ALIGN-3-TRACE: -Traceback= 60840858 607C25D4 607B6DAC 607E8D48 607E811C 607E8260 607E8E84 6055E0F4
Jan 30 14:57:12.591 PST: %ALIGN-3-TRACE: -Traceback= 60840844 607C25D4 607C69AC 607B6540 607B30C4 607B34C0 607E811C 607E8260
Jan 30 14:57:12.591 PST: %ALIGN-3-TRACE: -Traceback= 60840850 607C25D4 607C69AC 607B6540 607B30C4 607B34C0 607E811C 607E8260

The problem is not service impacting, but it will cause performance issues. The following syslog message will also be seen with each call:

Jan 30 20:30:14.547 PST: XCSP:Slot 2 not initialized

CSCdw62969

A network gateway (NAS) that is running Cisco IOS Release 12.2(02)XB3 or Release 12.2(8)T may reload when Layer 2 forwarding (L2F) virtual private dial-up network (VPDN) calls are placed using an authentication, authorization, and accounting (AAA) VPDN user profile that does not contain the RADIUS class (25) attribute.

Workaround: Configure a dummy RADIUS class (25) attribute in the VPDN user profile on the AAA server.

CSCdw66251

SIP gateway midcall INVITE requests in the called to calling party direction will have the Route header constructed incorrectly. ACK requests in the called to calling party direction will have the request URI constructed incorrectly. This could cause some operations such as T.38 fax relay to fail.

This problem can occur only if two or more SIP proxies are in the SIP signaling path and the Record Route feature is enabled.

Workaround: There is no workaround.

CSCdw67688

UPC324 cards might reload after running for a while. This might trigger RS reload in some cases. This might be service impacting.

CSCdw68066

A Cisco router that is configured as a Layer 2 Tunneling Protocol (L2TP) access concentrator (LAC) may not free memory properly if the vpdn authen-before-forward VPDN group mode command is configured.

Workaround: There is no workaround.

CSCdw68658

The gateway will reject a mid-call Invite with hold sdp where the connection information (c line) is set to 0.0.0.0 and the port number of the media description (m line) is also set to 0. Instead of responding with a 200 OK response, the gateway will return a 488 Media Unacceptable response. The problem will not occur if the user agent placing the gateway on hold, sets the port number to a value other than 0.

Workaround: There is no workaround.

CSCdw77524

When rtp payload-type cisco-codec-fax-ind is changed from 96 to 99 then we ingress an invite with sdp rtp payload type 96 nte the gateway responds with an rtp payload type 97. These 2 payload types are chosen for the proprietary implementation of Cisco fax-relay. Per RFC2833, the gateway should not be doing this. This affects all Cisco fax gateways which support Cisco fax-relay.

Workaround: Use the rtp payload-type command on the Cisco gateway to change the assignment of the payload types, but this command is broken.

CSCuk25642

When using callin authentication on a LSDO call with RADIUS, PPP sends multiple authorization requests to AAA. This will slow down call setup but have no functional impact.

CSCuk25721

RADIUS CLID attribute was missing for large scale dialout accounting.

CSCuk25947

If PPP authentication is configured on an interface and if a user negotiates a callback during a Link Control Protocol (LCP) operation, the call will fail if the user does not have any callback information configured.

Workaround: There is no workaround.

CSCuk26562

AAA id debugging was not clear and displayed far too much information.

CSCuk26642

RADIUS calls with a non-RFC supported value were accepted when they should be rejected.

CSCuk27924

send-auth would not be applied on the NAS, but rather the value of auth-type would be used instead.

CSCuk28445

We now store a generic 'wrapper' record which holds information in the tree, generic to all accounting records. This way, we are not impacted by the life-span of any one accounting record.


Open Caveats—Cisco IOS Release 12.2(2)XB3

There are no open caveats specific to Cisco IOS Release 12.2(2)XB3 that require documentation in the release notes.

Resolved Caveats—Cisco IOS Release 12.2(2)XB3

All the caveats listed in this section are resolved in Cisco IOS Release 12.2(2)XB3. This section describes only severity 1 and 2 caveats and select severity 3 caveats.

Table 20 Resolved Caveats for Cisco IOS Release 12.2(2)XB3

DDTS ID Number
Description

CSCdw65903

An error can occur with management protocol processing. Please use the following URL for further information:

http://www.cisco.com/cgi-bin/bugtool/onebug.pl?bugid=CSCdw65903


Open Caveats—Cisco IOS Release 12.2(2)XB2

All the caveats listed in this section are open in Cisco IOS Release 12.2(2)XB2. This section describes only severity 1 and 2 caveats and select severity 3 caveats.

Table 21 Open Caveats for Cisco IOS Release 12.2(2)XB2 

DDTS ID Number
Description

CSCdv88831

Symptom: Low Call Success Rate on Cisco AS5800 accompanied by premature disconnects.

Conditions: Cisco AS5800 Voice Gateway running Cisco IOS Release 12.1(5)XM6 with IVR calls. This symptom is seen even with the Cisco IOS Release 12.2(2)XB2 image.

Workaround: There is no workaround.

CSCdw05780

Symptom: Some MGCP hairpinned call flows will require an additional MDCX to work properly.

Conditions: The problem is that the MGCP state machine seems to behave differently for the two call flows below:

1. First is the "official" hairpinning call flow from the interface spec. The code seems more geared towards supporting this:

1B) CRCX(endpt B, nt:LOCAL) -> Created as hairpinned

1C) CRCX(endpt A, nt:LOCAL) -> Created as hairpinned

1D) MDCX(endpt B, nt:LOCAL) -> Tie the two together

2. Second is a call flow in which the first CRCX does not indicate hairpin (nt:IN) and that connection is later modified to be hairpinned (MDCX w/ nt:LOCAL):

2A) CRCX(endpt A, nt:IN) -> Starts out as non-hairpinned

2B) CRCX(endpt B, nt:LOCAL) -> Created as hairpinned

2C) MDCX(endpt A, nt:LOCAL) -> Changed to hairpinned

2D) MDCX(endpt B, nt:LOCAL) -> Tie the two together

<Things should be okay at this point but they're not an extra message is required:>

2E) MDCX(endpt A, nt:LOCAL) -> EXTRA, unnecessary message. This is a duplicate of message 2C

This caveat is the reason for "2E" message.

Workaround:

Do not create to-be-hairpinned connections in a non-hairpinned manner (i.e., use "nt:LOCAL" from the initial CRCX). As stated above, the official hairpin callflow already behaves this way.

Do not use hairpinned connections at all. This will require more system resources but may be the only workaround if the call agent is unable to determine, from the first CRCX, that the connection will be hairpinned.

Or

Use a call agent which will allow the second MDCX to be sent. This is an unlikely solution but may work for testing.

CSCdw14183

Crash at clock_get_time(). This defect was seen after including port modem start-up test command on the Cisco AS5800 on Cisco IOS Release 12.2XB2 image. There is no workaround.

CSCdw19733

A Cisco AS5800 is controlled by an MGC that support only RLM version 1 where only ISDN service messages and not Group Service Messages are supported. When a big number of controller flaps (for example when a T3 containing several T1 flaps) not all the ISDN service messages are sent. As a result the trunk (CIC) status on the MGC may be incongruent with the controller status on the Cisco AS5800.

Workaround: Use an MGC that supports RLM version 2 and ISDN group service messages.


Resolved Caveats—Cisco IOS Release 12.2(2)XB2

All the caveats listed in this section are resolved in Cisco IOS Release 12.2(2)XB2. This section describes only severity 1 and 2 caveats and select severity 3 caveats.

Table 22 Resolved Caveats for Cisco IOS Release 12.2(2)XB2 

DDTS ID Number
Description

CSCdv35958

MICA modems might be marked BUSIEDOUT or OOS after calls have been coming in and dropping

Workaround: Doing shut/no-shut brings the modems back to ACTIVE state.

CSCdv35939

Modems might be marked as BAD as a result of Port-Modem-Startup Test.

Workaround: Disable Port-Modem-Startup test and reboot the Cisco AS5800 RS.

CSCdv54898

Symptom: Low Call Success Rate on Cisco AS5800 accompanied by abnormal and premature disconnects.

Conditions: Cisco AS5800 Voice Gateway running Cisco IOS Release 12.1(5)XM5 with COT enabled. Also NO modem cards in the system.

Workaround: Either disable COT or Add a modem card to the system.

CSCdv58141

When doing DTMF Relay tone testing, Nextport presents a power level difference between the 2 frequencies of each digit (1234567890ABCD*#). This problem happens with Inband Signaling DTMF Relay method RTP-NTE generating and detecting digits.

CSCdv74216

Cisco AS5800 Voice Gateway reboots with "Watchdog hard reset" error during load/stress test.

CSCdv88723

Symptom: There is a memory leak for SS7 COT transponder calls at the egress gateway on stress testing.

Conditions: This is a voice only system and these are IVR calls.

Workaround: There is no workaround.

CSCdw17239

Symptom: The decoded information in the NAS-port attribute for an incoming call does not match the trunk/timeslot on which the call is connected.

Conditions: This problem occurs when using NAS-port formats A - C and E for calls using CAS & R2 signaling.

Workaround: There is no workaround for these conditions.

CAS calls using NAS Port formats A through C can result in having incorrect or incomplete information provided. This is a result of the fact that no real interface exists (other than the Async) for a CAS call. This results in the AAA code either rejecting the interface information (format C) or not displaying the interface type (formats A and B), resulting in a backward compatibility problem.


Open Caveats—Cisco IOS Release 12.2(2)XB1

This section documents possible unexpected behavior by Cisco IOS Release 12.2(2)XB1 and describes only severity 1 and 2 caveats and select severity 3 caveats.

Table 23 Open Caveats for Cisco IOS Release 12.2(2)XB1 

DDTS ID Number
Description

CSCdu82536

This defect is observed in the latest Cisco IOS Release 12.2(03)PI image. Whenever the active analog calls are cleared, the resource manager does not send the message to the resource-pool analog call counter resulting in the resource-pool showing active calls.

Workaround: There is no workaround.

CSCdu87596

This defect is to be seen when there is a stress test which is performed and after the stress test, the calltracker counter and resource-pool counters still show active calls even after the calls are cleared on the Cisco AS5800.

Workaround: The workaround for the calltracker counter is to disable the calltracker and then again enable it. For the resource-pool counter, the workaround is to reload the Cisco AS5800.

CSCdv35939

Modems might be marked as BAD as a result of Port-Modem-Startup Test.

Workaround: Disable Port-Modem-Startup test and reboot the Cisco AS5800 RS.

CSCdv35958

MICA modems might be marked BUSIEDOUT or OOS after calls have been coming in and dropping

Workaround: Doing shut/no-shut brings the modems back to ACTIVE state.

CSCdv41055

When issuing a busy out of an entire CE1 card using "busyout 1/0", the service messages are only generated for the first four E1 ports plus four B channels of the fifth port for a total of 128 service messages.

Workaround: The workaround is to busyout each E1 one at a time to ensure all B channels are taken out of service.

CSCdv54898

Symptom: Low Call Success Rate on Cisco AS5800 accompanied by abnormal and premature disconnects.

Conditions: Cisco AS5800 Voice Gateway running Cisco IOS Release 12.1(5)XM5 with COT enabled. Also NO modem cards in the system.

Workaround: Either disable COT or add a modem card to the system.

CSCdv58141

When doing DTMF Relay tone testing, Nextport presents a power level difference between the 2 frequencies of each digit (1234567890ABCD*#). This problem happens with Inband Signaling DTMF Relay method RTP-NTE generating and detecting digits.

CSCdv74913

Following Spurious Memory Accesses will be recorded on a Cisco AS5800 with Cisco IOS Release 12.2(2)XB1 while using AAA idle timeout feature.

Oct 30 17:22:05.220 PST:%ALIGN-3-SPURIOUS: Spurious memory access made at 0x604AA6A8 reading 0x30
Oct 30 17:22:05.220 PST: %ALIGN-3-TRACE: -Traceback= 604AA6A8 6049C6D0 607CFDBC 607D0308 607D02B0 607DC0E8 607DF268 607D0198
Oct 30 17:22:05.220 PST: %ALIGN-3-TRACE: -Traceback= 604AA6B4 6049C6D0 607CFDBC 607D0308 607D02B0 607DC0E8 607DF268 607D0198
Oct 30 17:24:05.260 PST: %ALIGN-3-SPURIOUS: Spurious memory access made at 0x604AA6A8 reading 0x30
Oct 30 17:24:05.260 PST: %ALIGN-3-TRACE: -Traceback= 604AA6A8 6049C6D0 607CFDBC 607D0308 607D02B0 607DC0E8 607DDA1C 607FE078
Oct 30 17:24:05.260 PST: %ALIGN-3-TRACE: -Traceback= 604AA6B4 6049C6D0 607CFDBC 607D0308 607D02B0 607DC0E8 607DDA1C 607FE078
NPE300-RS1#sh align
Alignment data for:
5800 Software (C5800-P4-M), Version 12.2(2)XB1, EARLY DEPLOYMENT RELEASE SOFTWARE (fc1)
TAC Support: http://www.cisco.com/tac
Compiled Mon 29-Oct-01 17:18 by liha
No alignment data has been recorded.
Total Spurious Accesses 756, Recorded 4
  Address Count Traceback
30 372 0x604AA6A8 0x6049C6D0 0x607CFDBC 0x607D0308
0x607D02B0 0x607DC0E8 0x607DF268 0x607D0198
214 372 0x604AA6B4 0x6049C6D0 0x607CFDBC 0x607D0308
0x607D02B0 0x607DC0E8 0x607DF268 0x607D0198
30 6 0x604AA6A8 0x6049C6D0 0x607CFDBC 0x607D0308
0x607D02B0 0x607DC0E8 0x607DDA1C 0x607FE078
214 6 0x604AA6B4 0x6049C6D0 0x607CFDBC 0x607D0308
0x607D02B0 0x607DC0E8 0x607DDA1C 0x607FE078

Workaround: Do not use idle timeout feature via RADIUS.

CSCdv74216

Cisco AS5800 Voice Gateway reboots with "Watchdog hard reset" error during load/stress test.

CSCdv76047

A voice call fails at the egress gateway with COT transponder turned on. There is a failure in the COT functionality.

Workaround: There is no workaround.


Resolved Caveats—Cisco IOS Release 12.2(2)XB1

All the caveats listed in this section are resolved in Cisco IOS Release 12.2(2)XB1. This section describes only severity 1 and 2 caveats and select severity 3 caveats.

Table 24 Resolved Caveats for Cisco IOS Release 12.2(2)XB1

DDTS ID Number
Description

CSCdv35939

Modems might be marked as BAD as a result of Port-Modem-Startup Test.

Workaround: Disable Port-Modem-Startup test and reboot the Cisco AS5800 RS.

CSCdv35958

MICA modems might be marked BUSIEDOUT or OOS after calls have been coming in and dropping

Workaround: Doing shut/no-shut brings the modems back to ACTIVE state.

CSCdv76047

A voice call fails at the egress gateway with COT transponder turned on. There is a failure in the COT functionality.

Workaround: There is no workaround.


Open and Resolved Caveats—Cisco IOS Release 12.2(2)XB

Cisco IOS Release 12.2(2)XB does not support the Cisco AS5800 universal access servers.

Related Documentation

The following sections describe the documentation available for the Cisco AS5800 universal access servers. These documents consist of hardware and software installation guides, Cisco IOS configuration guides and command references, system error messages, feature modules, and other documents.

Documentation is available as printed manuals or electronic documents, except for feature modules, which are available online on Cisco.com and the Documentation CD-ROM.

Use these release notes with these documents:

Release-Specific Documents

Platform-Specific Documents

Feature Modules

Feature Navigator

Cisco IOS Software Documentation Set

Release-Specific Documents

The following documents are specific to Cisco IOS Release 12.2 and are located on Cisco.com and the Documentation CD-ROM:

Cross-Platform Release Notes for Cisco IOS Release 12.2 

On Cisco.com at:

Cisco Product Documentation: Cisco IOS Software: Cisco IOS Release 12.2: Release Notes: Cross-Platform Release Notes

On the Documentation CD-ROM at:

Cisco Product Documentation: Cisco IOS Software Configuration: Cisco IOS Release 12.2: Release Notes: Cross-Platform Release Notes

Product bulletins, field notices, and other release-specific documents on Cisco.com at:

Technical Documents

The "Caveats for Cisco IOS Release 12.2 XB" section

As a supplement to the caveats listed in "Caveats for Cisco IOS Release 12.2 XB" in these release notes, see Caveats for Cisco IOS Release 12.2, which contains caveats applicable to all platforms for all maintenance releases of Cisco IOS Release 12.2.

On Cisco.com at:

Cisco Product Documentation: Cisco IOS Software: Cisco IOS Release 12.2: Release Notes: Caveats

On the Documentation CD-ROM at:

Cisco Product Documentation: Cisco IOS Software Configuration: Cisco IOS Release 12.2: Caveats


Note If you have an account with Cisco.com, you can also use the Bug Toolkit to find select caveats of any severity. To reach the Bug Toolkit, log in to Cisco.com and click Service & Support: Software Center: Cisco IOS Software: BUG TOOLKIT. Another option is to go to http://www.cisco.com/cgi-bin/Support/Bugtool/launch_bugtool.pl.


Platform-Specific Documents

These documents are available for the Cisco AS5800 universal access servers on Cisco.com and the Documentation CD-ROM:

Read Me First—For Cisco AS5800 Universal Gateway

Hardware Installation Documents for the Cisco AS5800 Universal Gateway

Configuration Documents for the Cisco AS5800 Universal Gateway

Cisco AS5800 Universal Gateway Regulatory Compliance and Safety Information

On Cisco.com at:

Cisco Product Documentation: Access Servers and Access Routers: Access Servers: Cisco AS5800

On the Documentation CD-ROM at:

Cisco Product Documentation: Access Servers and Access Routers: Access Servers: Cisco AS5800

Feature Modules

Feature modules describe new features supported by Cisco IOS Release 12.2(2)XB15 and are updates to the Cisco IOS documentation set. A feature module consists of a brief overview of the feature, benefits, configuration tasks, and a command reference. As updates, the feature modules are available online only. Feature module information is incorporated in the next printing of the Cisco IOS documentation set.

On Cisco.com at:

Cisco Product Documentation: Cisco IOS Software: Cisco IOS Release 12.2: New Feature Documentation

On the Documentation CD-ROM at:

Cisco Product Documentation: Cisco IOS Software Configuration: Cisco IOS Release 12.2: New Feature Documentation

Feature Navigator

Cisco IOS software is packaged in feature sets that are supported on specific platforms. To get updated information regarding platform support for this feature, access Cisco Feature Navigator. Cisco Feature Navigator dynamically updates the list of supported platforms as new platform support is added for the feature.

Cisco Feature Navigator is a web-based tool that enables you to quickly determine which Cisco IOS software images support a specific set of features and which features are supported in a specific Cisco IOS image. You can search by feature or release. Under the release section, you can compare releases side by side to display both the features unique to each software release and the features in common.

To access Cisco Feature Navigator, you must have an account on Cisco.com. If you have forgotten or lost your account information, send a blank e-mail to cco-locksmith@cisco.com. An automatic check will verify that your e-mail address is registered with Cisco.com. If the check is successful, account details with a new random password will be e-mailed to you. Qualified users can establish an account on Cisco.com by following the directions found at this URL:

http://www.cisco.com/register

Cisco Feature Navigator is updated regularly when major Cisco IOS software releases and technology releases occur. For the most current information, go to the Cisco Feature Navigator home page at the following URL:

http://www.cisco.com/cgi-bin/Support/FeatureNav/FN.pl

Cisco IOS Software Documentation Set

The Cisco IOS software documentation set consists of the Cisco IOS configuration guides, Cisco IOS command references, and several other supporting documents. The Cisco IOS software documentation set is shipped with your order in electronic form on the Documentation CD-ROM—unless you specifically ordered the printed versions.

Documentation Modules

Each module in the Cisco IOS documentation set consists of one or more configuration guides and one or more corresponding command references. Chapters in a configuration guide describe protocols, configuration tasks, and Cisco IOS software functionality, and contain comprehensive configuration examples. Chapters in a command reference provide complete command syntax information. Use each configuration guide with its corresponding command reference.

On Cisco.com at:

Technical Documents: Cisco IOS Software: Cisco IOS Release 12.2: Configuration Guides and Command References

On the Documentation CD-ROM at:

Cisco Product Documentation: Cisco IOS Software Configuration: Cisco IOS Release 12.2: Configuration Guides and Command References

Cisco IOS Release 12.2 Documentation Set Contents

Table 25 lists the contents of the Cisco IOS Release 12.2 software documentation set, which is available in electronic form and in printed form if ordered.


Note You can find the most current Cisco IOS documentation on Cisco.com and the Documentation CD-ROM.


On Cisco.com at:

Technical Documents: Cisco IOS Software: Cisco IOS Release 12.2

On the Documentation CD-ROM at:

Cisco Product Documentation: Cisco IOS Software Configuration: Cisco IOS Release 12.2

Table 25 Cisco IOS Release 12.2 Documentation Set 

Books
Major Topics

Cisco IOS Configuration Fundamentals Configuration Guide

Cisco IOS Configuration Fundamentals Command Reference

Cisco IOS User Interfaces
File Management
System Management

Cisco IOS Bridging and IBM Networking Configuration Guide

Cisco IOS Bridging and IBM Networking Command Reference, Volume 1 of 2

Cisco IOS Bridging and IBM Networking Command Reference, Volume 2 of 2

Transparent Bridging
SRB
Token Ring Inter-Switch Link
Token Ring Route Switch Module
RSRB
DLSW+
Serial Tunnel and Block Serial Tunnel
LLC2 and SDLC
IBM Network Media Translation
SNA Frame Relay Access
NCIA Client/Server
Airline Product Set
DSPU and SNA Service Point
SNA Switching Services
Cisco Transaction Connection
Cisco Mainframe Channel Connection
CLAW and TCP/IP Offload
CSNA, CMPC, and CMPC+
TN3270 Server

Cisco IOS Dial Technologies Configuration Guide: Dial Access

Cisco IOS Dial Technologies Configuration Guide: Large-Scale Dial Applications

Cisco IOS Dial Technologies Command Reference,
Volume 1 of 2

Cisco IOS Dial Technologies Command Reference,
Volume 2 of 2

Dial Access
Modem and Dial Shelf Configuration and Management
ISDN Configuration
Signaling Configuration
Point-to-Point Protocols
Dial-on-Demand Routing
Dial Backup
Dial Related Addressing Service
Network Access Solutions
Large-Scale Dial Solutions
Cost-Control Solutions
Internetworking Dial Access Scenarios

Cisco IOS Interface Configuration Guide

Cisco IOS Interface Command Reference

LAN Interfaces
Serial Interfaces
Logical Interfaces

Cisco IOS IP Configuration Guide

Cisco IOS IP Command Reference, Volume 1 of 3: Addressing and Services

Cisco IOS IP Command Reference, Volume 2 of 3: Routing Protocols

Cisco IOS IP Command Reference, Volume 3 of 3: Multicast

IP Addressing
IP Services
IP Routing Protocols
IP Multicast

Cisco IOS AppleTalk and Novell IPX Configuration Guide

Cisco IOS AppleTalk and Novell IPX Command Reference

AppleTalk
Novell IPX

Cisco IOS Apollo Domain, Banyan VINES, DECnet, ISO CLNS, and XNS Configuration Guide

Cisco IOS Apollo Domain, Banyan VINES, DECnet, ISO CLNS, and XNS Command Reference

Apollo Domain
Banyan VINES
DECnet
ISO CLNS
XNS

Cisco IOS Voice, Video, and Fax Configuration Guide

Cisco IOS Voice, Video, and Fax Command Reference

Voice over IP
Call Control Signaling
Voice over Frame Relay
Voice over ATM
Telephony Applications
Trunk Management
Fax, Video, and Modem Support

Cisco IOS Quality of Service Solutions Configuration Guide

Cisco IOS Quality of Service Solutions Command Reference

Packet Classification
Congestion Management
Congestion Avoidance
Policing and Shaping
Signaling
Link Efficiency Mechanisms

Cisco IOS Security Configuration Guide

Cisco IOS Security Command Reference

AAA Security Services
Security Server Protocols
Traffic Filtering and Firewalls
IP Security and Encryption
Passwords and Privileges
Neighbor Router Authentication
IP Security Options
Supported AV Pairs

Cisco IOS Switching Services Configuration Guide

Cisco IOS Switching Services Command Reference

Cisco IOS Switching Paths
NetFlow Switching
Multiprotocol Label Switching
Multilayer Switching
Multicast Distributed Switching
Virtual LANs
LAN Emulation

Cisco IOS Wide-Area Networking Configuration Guide

Cisco IOS Wide-Area Networking Command Reference

ATM
Frame Relay
SMDS
X.25 and LAPB

Cisco IOS Mobile Wireless Configuration Guide

Cisco IOS Mobile Wireless Command Reference

General Packet Radio Service

Cisco IOS Terminal Services Configuration Guide

Cisco IOS Terminal Services Command Reference

ARA
LAT
NASI
Telnet
TN3270
XRemote
X.28 PAD
Protocol Translation

Cisco IOS Configuration Guide Master Index

Cisco IOS Command Reference Master Index

Cisco IOS Debug Command Reference

Cisco IOS Software System Error Messages

New Features in 12.2-Based Limited Lifetime Releases

New Features in Release 12.2 T

Release Notes (Release note and caveat documentation for 12.2-based releases and various platforms)

 


Obtaining Documentation

These sections explain how to obtain documentation from Cisco Systems.

World Wide Web

You can access the most current Cisco documentation on the World Wide Web at this URL:

http://www.cisco.com

Translated documentation is available at this URL:

http://www.cisco.com/public/countries_languages.shtml

Documentation CD-ROM

Cisco documentation and additional literature are available in a Cisco Documentation CD-ROM package, which is shipped with your product. The Documentation CD-ROM is updated monthly and may be more current than printed documentation. The CD-ROM package is available as a single unit or through an annual subscription.

Ordering Documentation

You can order Cisco documentation in these ways:

Registered Cisco.com users (Cisco direct customers) can order Cisco product documentation from the Networking Products MarketPlace:

http://www.cisco.com/cgi-bin/order/order_root.pl

Registered Cisco.com users can order the Documentation CD-ROM through the online Subscription Store:

http://www.cisco.com/go/subscription

Nonregistered Cisco.com users can order documentation through a local account representative by calling Cisco Systems Corporate Headquarters (California, U.S.A.) at 408 526-7208 or, elsewhere in North America, by calling 800 553-NETS (6387).

Documentation Feedback

You can submit comments electronically on Cisco.com. In the Cisco Documentation home page, click the Fax or Email option in the "Leave Feedback" section at the bottom of the page.

You can e-mail your comments to bug-doc@cisco.com.

You can submit your comments by mail by using the response card behind the front cover of your document or by writing to the following address:

Cisco Systems
Attn: Document Resource Connection
170 West Tasman Drive
San Jose, CA 95134-9883

We appreciate your comments.

Obtaining Technical Assistance

Cisco provides Cisco.com as a starting point for all technical assistance. Customers and partners can obtain online documentation, troubleshooting tips, and sample configurations from online tools by using the Cisco Technical Assistance Center (TAC) Web Site. Cisco.com registered users have complete access to the technical support resources on the Cisco TAC Web Site.

Cisco.com

Cisco.com is the foundation of a suite of interactive, networked services that provides immediate, open access to Cisco information, networking solutions, services, programs, and resources at any time, from anywhere in the world.

Cisco.com is a highly integrated Internet application and a powerful, easy-to-use tool that provides a broad range of features and services to help you with these tasks:

Streamline business processes and improve productivity

Resolve technical issues with online support

Download and test software packages

Order Cisco learning materials and merchandise

Register for online skill assessment, training, and certification programs

If you want to obtain customized information and service, you can self-register on Cisco.com. To access Cisco.com, go to this URL:

http://www.cisco.com

Technical Assistance Center

The Cisco Technical Assistance Center (TAC) is available to all customers who need technical assistance with a Cisco product, technology, or solution. Two levels of support are available: the Cisco TAC Web Site and the Cisco TAC Escalation Center.

Cisco TAC inquiries are categorized according to the urgency of the issue:

Priority level 4 (P4)—You need information or assistance concerning Cisco product capabilities, product installation, or basic product configuration.

Priority level 3 (P3)—Your network performance is degraded. Network functionality is noticeably impaired, but most business operations continue.

Priority level 2 (P2)—Your production network is severely degraded, affecting significant aspects of business operations. No workaround is available.

Priority level 1 (P1)—Your production network is down, and a critical impact to business operations will occur if service is not restored quickly. No workaround is available.

The Cisco TAC resource that you choose is based on the priority of the problem and the conditions of service contracts, when applicable.

Cisco TAC Web Site

You can use the Cisco TAC Web Site to resolve P3 and P4 issues yourself, saving both cost and time. The site provides around-the-clock access to online tools, knowledge bases, and software. To access the Cisco TAC Web Site, go to this URL:

http://www.cisco.com/tac

All customers, partners, and resellers who have a valid Cisco service contract have complete access to the technical support resources on the Cisco TAC Web Site. The Cisco TAC Web Site requires a Cisco.com login ID and password. If you have a valid service contract but do not have a login ID or password, go to this URL to register:

http://www.cisco.com/register/

If you are a Cisco.com registered user, and you cannot resolve your technical issues by using the Cisco TAC Web Site, you can open a case online by using the TAC Case Open tool at this URL:

http://www.cisco.com/tac/caseopen

If you have Internet access, we recommend that you open P3 and P4 cases through the Cisco TAC Web Site.

Cisco TAC Escalation Center

The Cisco TAC Escalation Center addresses priority level 1 or priority level 2 issues. These classifications are assigned when severe network degradation significantly impacts business operations. When you contact the TAC Escalation Center with a P1 or P2 problem, a Cisco TAC engineer automatically opens a case.

To obtain a directory of toll-free Cisco TAC telephone numbers for your country, go to this URL:

http://www.cisco.com/warp/public/687/Directory/DirTAC.shtml

Before calling, please check with your network operations center to determine the level of Cisco support services to which your company is entitled: for example, SMARTnet, SMARTnet Onsite, or Network Supported Accounts (NSA). When you call the center, please have available your service agreement number and your product serial number.

 


hometocprevnextglossaryfeedbacksearchhelp

Posted: Thu Jan 27 17:18:14 PST 2005
All contents are Copyright © 1992--2005 Cisco Systems, Inc. All rights reserved.