|
This chapter describes our support for Systems Network Architecture (SNA) downstream physical unit (DSPU) devices. For a complete description of the commands mentioned in this chapter, refer to the "DSPU Configuration Commands" chapter of the Router Products Command Reference publication.
DSPU is a software feature that enables the router to function as a physical unit (PU) concentrator for SNA PU type 2 nodes. PU concentration at the router simplifies the task of PU definition at the upstream host while providing additional flexibility and mobility for downstream PU devices.
The DSPU feature allows you to define downstream PU type 2 devices in the router. DSPU reduces the complexity of host configuration by letting you replace multiple PU definitions that represent each downstream device with one PU definition that represents the router.
Because you define the downstream PUs at the router rather than the host, you isolate the host from changes in the downstream network topology. Therefore you can insert and remove downstream PUs from the network without making any changes on the host.
The concentration of downstream PUs at the router also reduces network traffic on the wide-area Network (WAN) by limiting the number of sessions that must be established and maintained with the host. The termination of downstream sessions at the router ensures that idle session traffic does not appear on the WAN.
Figure 27-1 shows a router functioning as a DSPU concentrator.
Typically, the router establishes one or more upstream connections with one or more hosts and many downstream connections with PU type 2 devices. From an SNA perspective, the router appears as a PU type 2 device to the upstream host and assumes the role of a System Services Control Point (SSCP) appearing as a PU type 5 device to its downstream PUs.
The SSCP sessions established between the router and its upstream host are completely independent of the SSCP sessions established between the router and its downstream PUs. SNA traffic is routed at a logical unit (LU) level using a routing algorithm that maps downstream LUs onto upstream LUs.
Figure 27-2 illustrates the SNA perspective of DSPU.
To configure DSPU, perform the tasks in the following sections. The last two tasks are optional.
See the end of this chapter for "DSPU Configuration Examples."
The upstream host provides LUs that the router will assign for use by its downstream PUs. Since one upstream host can only provide a maximum of 255 LUs, the DSPU feature supports multiple hosts. Multiple upstream host support allows the DSPU router to provide more than 255 LUs for use by its downstream PUs.
To define a DSPU host, perform the following task in global configuration mode:
To define the downstream PUs, perform either of the tasks in the following sections, depending on your circumstances:
Explicitly define a downstream PU if you require the router to perform verification checking on incoming downstream connections or to initiate an outgoing downstream connection.
To explicitly define a downstream PU, perform the following task in global configuration mode:
Task | Command |
---|---|
dspu pu pu-name [rmac remote-mac] [rsap remote-sap] [lsap local-sap] [xid-rcv xid] [window window-size] [maxiframe max-iframe] [retries retry-count] [retry-timeout retry-timeout] |
If the router will perform verification checking on incoming downstream connections, there are several combinations of parameters that you can configure for verification matching:
The router will reject any incoming downstream connections that do not match the parameters of a defined downstream PU unless the default PU option is also enabled.
Configure the DSPU default PU option if you do not require the router to verify incoming downstream connections. The default PU option allows the router to accept incoming downstream connections without an explicit definition for the downstream PU.
To enable the default PU option, perform the following task in global configuration mode:
Task | Command |
---|---|
You must specify the LU routing algorithm used to map the upstream LUs to the downstream LUs and to define all LUs for each upstream and downstream PU.
The DSPU feature assigns upstream LUs onto downstream LUs based on the selected LU routing algorithm and performs the mapping necessary for SNA data transfer.
The DSPU feature supports two alternative mapping algorithms that are described in the following sections:
An upstream host PU or downstream PU can support up to 255 LU sessions. The DSPU feature allows each LU to be individually configured for either dedicated LU routing or pooled LU routing.
You can configure an upstream LU such that it is reserved, or dedicated, for use by a specific downstream LU.
To define a dedicated LU or a range of dedicated LUs for an upstream host and downstream PU, perform the following task in global configuration mode:
Task | Command |
---|---|
Define a dedicated LU or a range of dedicated LUs for a downstream PU. |
dspu lu lu-start [lu-end] host host-name host-lu-start [pu pu-name] |
See the "Dedicated LU Routing Example" section later in this chapter for an example of dedicated LU routing.
You can configure an upstream host LU such that it is a member of a pool of LUs. When a downstream connection is established and the downstream LU is configured as a pooled LU, the router selects an upstream LU from the pool for assignment to the downstream LU.
Pooled LU routing allows a limited number of upstream host LUs to be shared (at different times) among many downstream PUs.
To define a host LU or a range of host LUs in an LU pool, perform the following task in global configuration mode:
Task | Command |
---|---|
dspu pool pool-name host host-name lu lu-start [lu-end] [inactivity-timeout inactivity-minutes] |
You can configure a downstream LU as a pooled LU. When a downstream connection is established and the downstream LU is configured as a pooled LU, the router selects an upstream LU from the specified pool for assignment to the downstream LU.
To define a pooled LU or a range of pooled LUs for a downstream PU, perform the following task in global configuration mode:
See the "Pooled LU Routing Example" section later in this chapter for an example of pooled LU routing.
The final step in configuring DSPU is to define the data link controls that will be used for upstream host and downstream PU connections.
The DSPU feature supports the data link controls described in the following sections:
You configure DSPU for a data link control by enabling a local SAP for either upstream or downstream connections. Each data link control owns 255 SAPs that can be enabled for DSPU connections. A local SAP can be enabled for either upstream or downstream connections; a local SAP cannot be enabled for both upstream and downstream connections on the same data link control.
To enable a local SAP on the Token Ring interface for use by upstream hosts, perform the following task in interface configuration mode:
To enable a local SAP on the Token Ring interface for use by downstream PUs, perform the following task in interface configuration mode:
To initiate a connection with a remote upstream host or a downstream PU on the Token Ring interface, perform the following task in interface configuration mode:
To configure DSPU to use RSRB you must create a DSPU/RSRB data link control.
Similar to our implementation of SDLLC, the DSPU/RSRB data link control uses the concept of a virtual Token Ring device residing on a virtual Token Ring to represent the router to upstream hosts and downstream PUs across an RSRB network.
Since the upstream host and/or downstream PU expects its peer to also be on a Token Ring, you must assign a virtual Token Ring address (the DSPU virtual MAC address) to the DSPU/RSRB data link control. Like real Token Ring addresses, the DSPU virtual MAC address must be unique across the network.
In addition to assigning the DSPU virtual Mac address, you must also assign a DSPU virtual ring number to the DSPU/RSRB data link control. The DSPU virtual ring number must be unique across the network.
Note The DSPU virtual ring number is a different number than the virtual ring group numbers that you use to configure RSRB and multiport bridging.
The combination of the DSPU virtual MAC address and the DSPU virtual ring number identifies the DSPU/RSRB data link control interface to the rest of an RSRB network.
When an end station (either an upstream host or a downstream PU) attempts to connect with the DSPU router, the following occurs:
1. The end station sends explorer packets with the DSPU virtual MAC address as the destination address in the MAC headers.
2. The router configured with that DSPU virtual MAC address intercepts the frame, fills in the DSPU virtual ring number and the DSPU bridge number in the Routing Information Field (RIF), and sends the response back to the end station.
3. The end station establishes a session with the DSPU router.
To define the DSPU/RSRB data link control interface, perform the following tasks in global configuration mode:
After you define the DSPU RSRB data link control, you configure DSPU to use the RSRB data link control by enabling a local SAP for either upstream or downstream connections.
To enable a local SAP on RSRB for use by upstream hosts, perform the following task in global configuration mode:
To enable a local SAP on RSRB for use by downstream PUs, perform the following task in global configuration mode:
To initiate a connection with a remote upstream host or downstream PU over RSRB, perform the following task in global configuration mode:
Configuring DSPU to use RSRB with local acknowledgment is identical to configuring RSRB with local acknowledgment. If you add the local-ack keyword to the source-bridge remote-peer configuration command DSPU will use local-acknowledgment for any end stations that connect to DSPU from that peer.
To configure DSPU to use RSRB with local acknowledgment, perform the following tasks in global configuration mode:
Task | Command |
---|---|
source-bridge remote-peername ring-group ring-group tcp ip-address local-ack |
|
dspu rsrb local-virtual-ring bridge-number target-virtual-ring virtual-macaddr |
The DSPU feature allows you to define the number of activation request units (RUs) such as ACTLUs or DDDLU NMVTs that can be sent by the router before waiting for responses from the remote PU.
The DSPU activation window provides pacing to avoid depleting the router buffer pool during PU activation. Increasing the window size allows more LUs to become active in a shorter amount of time (assuming the required buffers for activation RUs are available). Decreasing the window size limits the amount of buffers the DSPU may use during PU activation. Typically, you do not need to change the default window size.
To define the number of unacknowledged activation RUs that can be outstanding, perform the following task in global configuration mode:
You can monitor the status of the DSPU feature. To display information about the state of the DSPU feature, perform the following tasks in EXEC mode:
Task | Command |
---|---|
The following sections provide DSPU configuration examples:
Figure 27-3 illustrates the use of dedicated LU routing. Each upstream host LU is dedicated for use by a specific downstream LU.
The following is a configuration file for the dedicated LU routing shown in Figure 27-3:
Figure 27-4 illustrates the use of pooled LU routing. Each upstream LU is configured in the LU pool and each downstream LU is configured as a pooled LU.
The following is the configuration example for the pooled LU routing shown in Figure 27-4:
The following configuration example represents one possible definition for the network topology shown earlier in Figure 27-1:
Posted: Wed Jul 2 23:21:46 PDT 2003
All contents are Copyright © 1992--2003 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.