cc/td/doc/product/software/ios102
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table of Contents

ISDN Switch Types, Codes, and Values

ISDN Switch Types, Codes, and Values

This appendix contains a list of the supported switch types. It also contains the ISDN cause codes, ISDN bearer capability values, and progress description field values that are valid within the debug commands for ISDN.


Note The ITU-T carries out the functions of the former Consultative Committee for International Telegraph and Telephone (CCITT).

Table B-1 lists the ISDN switch types supported by the ISDN interface.


Supported ISDN Switch Types
Identifier Description
basic-net3 Basic rate switches for United Kingdom and Europe
basic-5ess AT&T basic rate switches
basic-dms100 NT DMS-100 basic rate switches
vn2 French VN2 ISDN switches
vn3 French VN3 ISDN switches
ntt Japanese NTT ISDN switches
basic-1tr6 German 1TR6 ISDN switches
basic-ni1 National ISDN-1 switches
basic-TS013 Australian TS013 switches
none Disables the switch on the ISDN interface

Table B-2 lists the ISDN cause code fields that display in the following format within the debug commands:

i=0xy1y2z1z2a1a2
ISDN Cause Code Fields
Field Value--Description
0x Indicates that the values that follow are in hexadecimal
y1 8--ITU-T standard coding.
y2 0--User

1--Private network serving local user

2--Public network serving local user

3--Transit network

4--Public network serving remote user

5--Private network serving remote user

7--International network

A--Network beyond internetworking point

z1 Class of cause value.
z2 Value of cause value.
a1 (Optional) Diagnostic field that is always 8.
a2 (Optional) Diagnostic field that is one of the following values:

0--Unknown

1--Permanent

2--Transient

Table B-3 lists descriptions of the cause value field of the cause information element. The notes referred to in the Diagnostics column follow the table.


ISDN Cause Values
Cause Value Cause
Number
Cause Diagnostics
Class Value
0 0 0 0 0 0 1 1 Unallocated (unassigned) number Note 12
0 0 0 0 0 1 0 2 No route to specified transit network Transit network identity (Note 11)
0 0 0 0 0 1 1 3 No route to destination Note 12
0 0 0 0 1 1 0 6 Channel unacceptable
0 0 0 0 1 1 1 7 Call awarded and being delivered in an established channel
0 0 1 0 0 0 0 16 Normal call clearing Note 12
0 0 1 0 0 0 1 17 User busy
0 0 1 0 0 1 0 18 No user responding
0 0 1 0 0 1 1 19 No answer from user (user alerted)
0 0 1 0 1 0 1 21 Call rejected Note 12. User supplied diagnostic (Note 4)
0 0 1 0 1 1 0 22 Number changed
0 0 1 1 0 1 0 26 Non-selected user clearing
0 0 1 1 0 1 1 27 Designation out of order
0 0 1 1 1 0 0 28 Invalid number format
0 0 1 1 1 0 1 29 Facility rejected Facility identification (Note 1)
0 0 1 1 1 1 0 30 Response to STATUS ENQUIRY
0 0 1 1 1 1 1 31 Normal, unspecified
0 1 0 0 0 1 0 34 No circuit/channel available Note 10
0 1 0 0 1 1 0 38 Network out of order
0 1 0 1 0 0 1 41 Temporary failure
0 1 0 1 0 1 0 42 Switching equipment congestion
0 1 0 1 0 1 1 43 Access information discarded Discarded information element identifier(s) (Note 6)
0 1 0 1 1 0 0 44 Requested circuit/channel not available Note 10
0 1 0 1 1 1 1 47 Resources unavailable, unspecified
0 1 1 0 0 0 1 49 Quality of service unavailable Table B-2
0 1 1 0 0 1 0 50 Requested facility not subscribed Facility identification (Note 1)
0 1 1 1 0 0 1 57 Bearer capability not authorized Note 3
0 1 1 1 0 1 0 58 Bearer capability not presently available Note 3
0 1 1 1 1 1 1 63 Service or option not available, unspecified
1 0 0 0 0 0 1 65 Bearer capability not implemented Note 3
1 0 0 0 0 1 0 66 Channel type not implemented Channel Type (Note 7)
1 0 0 0 1 0 1 69 Requested facility not implemented Facility Identification (Note 1)
1 0 0 0 1 1 0 70 Only restricted digital information bearer capability is available
1 0 0 1 1 1 1 79 Service or option not implemented, unspecified
1 0 1 0 0 0 1 81 Invalid call reference value
1 0 1 0 0 1 0 82 Identified channel does not exist Channel identity
1 0 1 0 0 1 1 83 A suspended call exists, but this call identity does not
1 0 1 0 1 0 0 84 Call identity in use
1 0 1 0 1 0 1 85 No call suspended
1 0 1 0 1 1 0 86 Call having the requested call identity has been cleared Clearing cause
1 0 1 1 0 0 0 88 Incompatible destination Incompatible parameter (Note 2)
1 0 1 1 0 1 1 91 Invalid transit network selection
1 0 1 1 1 1 1 95 Invalid message, unspecified
1 1 0 0 0 0 0 96 Mandatory information element is missing Information element identifier(s) (Note 6)
1 1 0 0 0 0 1 97 Message type non-existent or not implemented Message type
1 1 0 0 0 1 0 98 Message not compatible with call state or message type non-existent or not implemented Message type
1 1 0 0 0 1 1 99 Information element non-existent or not implemented Information element identifier(s) (Notes 6, 8)
1 1 0 0 1 0 0 100 Invalid information element contents Information element identifier(s) (Note 6)
1 1 0 0 1 0 1 101 Message not compatible with call state Message type
1 1 0 0 1 1 0 102 Recovery on timer expires Timer number (Note 9)
1 1 0 1 1 1 1 111 Protocol error, unspecified
1 1 1 1 1 1 1 127 Internetworking, unspecified

Note 1: The coding of facility identification is network dependent.

Note 2: Incompatible parameter is composed of incompatible information element identifier.

Note 3: The format of the diagnostic field for cause 57, 58, and 65 is shown in the ITU-T Q.931 specification.

Note 4: User-supplied diagnostic field is encoded according to the user specification, subject to the maximum length of the cause information element. The coding of user-supplied diagnostics should be made in such a way that it does not conflict with the coding described in Table B-2.

Note 5: New destination is formatted as the called party number information element, including information element identifier. Transit network selection may also be included.

Note 6: Locking and non-locking shift procedures described in the ITU-T Q.931 specification apply. In principle, information element identifiers are in the same order as the information elements in the received message.

Note 7: The following coding is used:

Note 8: When only locking shift information element is included and no variable length information element identifier follows, it means that the codeset in the locking shift itself is not implemented.

Note 9: The timer number is coded in IA5 characters. The following coding is used in each octet:

Note 10: Examples of the cause values to be used for various busy/congestion condition appear in Annex J of the ITU-T Q.931 specification.

Note 11: The diagnostic field contains the entire transit network selection or network-specific facilities information element, as applicable.

Table B-4 lists the ISDN bearer capability values that display in the following format within the debug commands:

0x8890 for 64Kbps or 0x218F for 56 Kbps
ISDN Bearer Capability Values
Field Value--Description
0x Indication that the values that follow are in hexadecimal
88 ITU-T coding standard; unrestricted digital information
90 Circuit mode, 64 Kbps
21 Layer 1, V.110/X.30
8F Synchronous, no in-band negotiation, 56Kbps

Table B-5 lists the values of the Progress description field contained in the ISDN Progress indicator information element.


Progress Description Field Values
Bits Number Description
0000001 1 Call is not end-to-end ISDN, further call progress information may be available in-band
0000010 2 Destination address is non-ISDN
0000011 3 Origination address is non-ISDN
0000100 4 Call has returned to the ISDN
0001000 8 In-band information or appropriate pattern now available.

All other values for the progress description field are reserved.