This section describes the function and displays the syntax of each LLC2 and SDLC command. For more information about defaults and usage guidelines, see the corresponding chapter of the Router Products Command Reference publication.

encapsulation sdlc-primary

Use the encapsulation sdlc-primary interface configuration command to configure the router as the primary SDLC station.

encapsulation sdlc-secondary

Use the encapsulation sdlc-secondary interface configuration command to configure the router as a secondary SDLC station.

llc2 ack-delay-time milliseconds

Use the llc2 ack-delay-time interface configuration command to set the amount of time the router waits for an acknowledgment before sending the next set of information frames.

milliseconds Number of milliseconds the router allows incoming information frames to stay unacknowledged. This is a number in the range 1 to 60000. The default is 3200 milliseconds.

llc2 ack-max packet-count

Use the llc2 ack-max interface configuration command to control the maximum amount of information frames the router can receive before it must send an acknowledgment.

packet-count Maximum number of packets the router will receive before sending an acknowledgment. This is a number in the range 1 to127. The default is 3 packets.

llc2 idle-time milliseconds

Use the llc2 idle-time interface configuration command to control the frequency of polls during periods of idle time (no traffic).

milliseconds Number of milliseconds that can pass with no traffic before the LLC2 station sends a Receiver Ready frame. This is a number in the range 1 to 60000. The default is 10000 milliseconds.

llc2 local-window packet-count

Use the llc2 local-window interface configuration command to control the maximum number of information frames the router sends before it waits for an acknowledgment.

packet-count Maximum number of packets that can be sent before the router must wait for an acknowledgment. This is a number in the range 1 to 127 packets. The default is 7 packets.

llc2 n2 retry-count

Use the llc2 n2 interface configuration command to control the amount of times the router retries sending unacknowledged frames or repolls remote busy stations.

retry-count Number of times the router retries operations. This is a number in the range 1 to 255. The default is 8 retries.

llc2 t1-time milliseconds

Use the llc2 t1-time interface configuration command to control the amount of time the router will wait before resending unacknowledged information frames.

milliseconds Number of milliseconds the router waits before resending unacknowledged information frames. This is a number in the range 1 to 60000. The default is 1000 milliseconds.

llc2 tbusy-time milliseconds

Use the llc2 tbusy-time interface configuration command to control the amount of time the router waits until repolling a busy remote station.

milliseconds Number of milliseconds the router waits before repolling a busy remote station. This is a number in the range 1 to 60000. The default is 9600 milliseconds.

llc2 tpf-time milliseconds

Use the llc2 tpf-time interface configuration command to set the amount of time the router waits for a final response to a poll frame before resending the poll frame.

milliseconds Number of milliseconds the router waits for a final response to a poll frame before resending the poll frame. This is a number in the range 1 to 60000. The default is 1000 milliseconds.

llc2 trej-time milliseconds

Use the llc2 trej-time interface configuration command to control the amount of time a router waits for a correct frame after sending a reject (REJ) command to the remote LLC2 station.

milliseconds Number of milliseconds the router waits for a resend of a rejected frame before sending a reject command to the remote station. This is a number in the range 1 to 60000. The default is 3200 milliseconds.

llc2 xid-neg-val-time milliseconds

Use the llc2 xid-neg-val-tim interface configuration command to control the frequency of exchange of identification (XID) transmissions by the router.

milliseconds Number of milliseconds after which the router sends XID frames to other LLC2-speaking stations. This is a number in the range 1 to 60000. The default is 0 milliseconds.

llc2 xid-retry-time milliseconds

Use the llc2 xid-retry-time interface configuration command to set the amount of time the router waits for a reply to exchange of identification (XID) frames before dropping the session.

milliseconds Number of milliseconds the router waits for a reply to XID frame before dropping a session. This is a number in the range 1 to 60000. The default is 60000 milliseconds.

sdlc address hexbyte [echo]
no sdlc address hexbyte

Use the sdlc address interface configuration command to assign a set of secondary stations attached to the serial link. Use the no form of this command to remove an assigned secondary station.

hexbyte Hexadecimal number (base 16) indicating the address of the serial link.
echo (Optional) Treats nonecho and echo SDLC addresses as the same address.

sdlc cts-delay unit

Use the sdlc cts-delay interface configuration command to adjust the delay between the detection of RTS (request to send) and the assertion of CTS (clear to send) on an interface that is in half-duplex mode and that has been configured for DCE.

unit The delay in microseconds. This is a number in the range 1 to 64000. Each unit is approximately 5 microseconds. The default is 3 units (approximately 15 microseconds).

sdlc dte-timeout unit

Use the sdlc dte-timeout interface configuration command to adjust the amount of time a data terminal equipment (DTE) interface waits for the DCE to assert a clear to send (CTS) before dropping a request to send (RTS).

unit Timeout wait interval in microseconds. This is a number in the range 10 to 64000. Each unit is approximately 5 microseconds. The default is 10 units (approximately 50 microseconds).

[no] sdlc frmr-disable

Use the sdlc frmr-disable interface configuration command to indicate that secondary stations on a particular serial link do not support Frame Rejects (FRMRs) or error indications. Use the no form of this command to specify that the secondary station does support FRMRs.

[no] sdlc hdx

Use the sdlc hdx interface configuration command to configure an interface for half-duplex mode. Use the no form of this command to reset the interface for full-duplex mode.

sdlc holdq address queue-size

Use the sdlc holdq interface configuration command to control the maximum number of packets that can be held in a buffer before being transmitted to a remote SDLC station.

address SDLC address for which you are specifying a queue size.
queue-size Router's local send window size. The minimum is 1 packet. No maximum value has been established. The default is 12 packets.

sdlc k window-size

Use the sdlc k interface configuration command to set the window size in order to control the maximum number of information frames a router receives before sending an acknowledgment.

window-size Router's local send window size. This is a number in the range 1 to 7. The default is 7 frames.

sdlc line-speed rate

Use the sdlc line-speed interface configuration command to enable adaptive SDLC T1.

rate Clockrate in bits per second

sdlc n1 bit-count

Use the sdlc n1 interface configuration command to control the maximum size of an incoming frame.

bit-count Number indicating bit size. Frames that exceed this size are rejected. This is a number in the range 1 to 12000. The default is 12000 bits.

sdlc n2 retry-count

Use the sdlc n2 interface configuration command to determine the number of times that a router resends a frame before terminating the SDLC session.

retry-count Number of retry attempts. When this number is exceeded, the SDLC station terminates its session with the other station. This is a number in the range 1 to 255. The default is 20 retries.

[no] sdlc poll-limit-value count

Use the sdlc poll-limit-value interface configuration command to control how many times a single secondary station can be polled for input before the next station must be polled. Use the no form of this command to retrieve the default value.

count Number of times the router can poll one secondary station before proceeding to the next station. This is a number in the range 1 to 10. The default is 1 time.

[no] sdlc poll-pause-timer milliseconds

Use the sdlc poll-pause-timer interface configuration command to control how long the router pauses between sending each poll frame to secondary stations on a single serial interface. Use the no form of this command to retrieve the default value.

milliseconds Number of milliseconds that the router waits before sending the poll frame to a single serial interface. This is a number in the range 1 to 10000. The default is 100 milliseconds.

sdlc poll-wait-timeout milliseconds

Use the sdlc poll-wait-timeout interface configuration command when the router has been configured for local acknowledgment and some form of SDLC communication (SDLLC or STUN, for example), to specify the interval the router will wait for polls from a primary node before timing out that connection.

milliseconds Number of milliseconds the router will wait for a poll from the primary station before timing out the connection to the primary station. This is a number in the range 10 to 64000. The default is 10000 milliseconds.

sdlc rts timeout unit

Use the sdlc rts timeout interface configuration command to adjust the amount of time the interface waits for the DCE to assert clear to send (CTS) before dropping a request to send (RTS). Use this command on an interface that is in half-duplex mode and that has been configured for DCE.

unit Time in microseconds. This is a number in the range 10 to 64000. Each unit is approximately 5 microseconds. The default is 10 units (approximately 50 microseconds).

sdlc slow-poll seconds
no sdlc slow-poll

Use the sdlc slow-poll interface configuration command to enable the slow-poll capability of the router as a primary SDLC station. Use the no form of this command to disable slow-poll capability.

seconds Time in seconds; the default is 10 seconds.

sdlc t1 milliseconds

Use the sdlc t1 interface configuration command to control the amount of time the router waits for an acknowledgment to a frame or sequence of frames.

milliseconds Number of milliseconds that the router waits. This is a number in the range 1 to 64000. The default is 3000 milliseconds.

show interfaces

Use the show interfaces privileged EXEC command to display the SDLC information for a given SDLC interface.

show llc2

Use the show llc2 privileged EXEC command to display the LLC2 connections active in the router.

hometocprevnextglossaryfeedbacksearchhelp
Copyright 1989-1997 © Cisco Systems Inc.