This section describes the function and displays the syntax of each Frame Relay command. For more information about defaults and usage guidelines, see the corresponding chapter of the Router Products Command Reference publication.
To clear dynamically created Frame Relay maps, which are created by the use of inverse ARP, use the clear frame-relay-inarp EXEC command.
[no] encapsulation frame-relay [ietf]
Use the encapsulation frame-relay interface configuration command to enable Frame Relay encapsulation. The no form of this command disables Frame Relay. If the ietf keyword is not specified, this command defaults to using Cisco's encapsulation, which is a four-byte header, with two bytes for the DLCI and two bytes to identify the packet type.
ietf | (Optional) Sets the encapsulation method to comply with the IETF standard (RFC 1294). Use this keyword when connecting to another vendor's equipment across a Frame Relay network. |
[no] frame-relay interface-dlci dlci [option]
Use the frame-relay interface-dlci interface configuration command to allow use of subinterfaces in the Frame Relay network. To remove this feature, use the no form of this command.
dlci | DLCI number for the interface |
option | (Optional) Broadcast or encapsulation keyword, as defined in the Frame Relay subinterface configuration options table in the Router Products Command Reference publication |
frame-relay intf-type [dce | dte | nni]
no frame-relay intf-type [dce | dte]
Use the frame-relay intf-type interface configuration command to configure a Frame Relay switch type. Use the no form of this command to disable the switch.
dce | (Optional) Router functions as a switch connected to a router. |
dte | (Optional) Router is connected to a Frame Relay network. The default is DTE. |
nni | (Optional) Router functions as a switch connected to a switch (supports NNI connections). |
[no] frame-relay inverse-arp protocol dlci
Use the frame-relay inverse-arp interface configuration command to enable the Inverse Address Resolution Protocol (Inverse ARP) on the router configured for Frame Relay. Use the no form of this command to disable this feature.
protocol | Supported protocols: appletalk, decnet, ip, ipx, vines, and xns. |
dlci | DLCI number for the interface. Acceptable numbers are integers in the range 16 to 1007. |
frame-relay keepalive number
no frame-relay keepalive
Use the frame-relay keepalive interface configuration command to enable the Local Management Interface (LMI) mechanism for serial lines using Frame Relay encapsulation. Use the no form of this command to disable this capability.
number | An integer that defines the keepalive interval. The interval must be set and must be less than the interval set on the switch; see the frame-relay lmi-t392dce command description. The default is 10 seconds. |
[no] frame-relay lmi-n391dte keep-exchanges
Use the frame-relay lmi-n391dte interface configuration command to set a full status polling interval. Use the no form of this command to restore the default interval value, assuming an LMI has been configured.
keep-exchanges | Number of keep exchanges to be done before requesting a full status message. Acceptable value is a positive integer in the range 1 through 255. The default is 6. |
[no] frame-relay lmi-n392dce threshold
Use the frame-relay lmi-n392dce interface configuration command to set the DCE and NNI error threshold. Use the no form of this command to remove the current setting.
threshold | Error threshold value. Acceptable value is a positive integer in the range 1 through 10. The default is 2. |
[no] frame-relay lmi-n392dte threshold
Use the frame-relay lmi-n392dte interface configuration command to set the error threshold on a DTE or NNI interface. Use the no form of this command to remove the current setting.
threshold | Error threshold value. Acceptable value is a positive integer in the range 1 through 10. The default is 2. |
[no] frame-relay lmi-n393dce events
Use the frame-relay lmi-n393dce interface configuration command to set the DCE and NNI monitored events count. Use the no form of this command to remove the current setting.
events | Monitored events count value. Acceptable value is a positive integer in the range 1 through 10. The default is 2. |
[no] frame-relay lmi-n393dte events
Use the frame-relay lmi-n393dte interface configuration command to set the monitored event count on a DTE or NNI interface. Use the no form of this command to remove the current setting.
events | Monitored event count value. Acceptable value is a positive integer in the range 1 through 10. The default is 2. |
[no] frame-relay lmi-t392dce timer
Use the frame-relay lmi-t392dce interface configuration command to set the polling verification timer on a DCE or NNI interface. Use the no form of this command to remove the current setting.
timer | Polling verification timer value. Acceptable value is a positive integer in the range 5 through 30. The default is 15 seconds. |
frame-relay lmi-type {cisco | ansi | q933a}
no frame-relay lmi-type {ansi | q933a}
Use the frame-relay lmi-type interface configuration command to select the Local Management Interface (LMI) type. Use the no form of this command to return to the default LMI type.
cisco | Group of 4 LMI. The default is Cisco LMI. |
ansi | Annex D defined by ANSI standard T1.617. |
q933a | International Telecommunication Union Telecommunication Standardization Sector (ITU-T, formerly called CCITT) Q.933 Annex A. |
frame-relay local-dlci number
no frame-relay local-dlci
Use the frame-relay local-dlci interface configuration command to set the source DLCI for use when the LMI is not supported. Use the no form of this command to remove the DLCI number.
number | Local (source) data link connection identifier (DLCI) number for the interface. |
frame-relay map protocol protocol-address dlci [broadcast]
[ietf | cisco]
no frame-relay map protocol protocol-address
Use the frame-relay map interface configuration command to define the mapping between an address and the DLCI used to connect to the address. Use the no form of this command to delete the map entry.
protocol | Supported protocols: appletalk, decnet, ip, xns, ipx, and vines. |
protocol-address | Address for the protocol. |
dlci | DLCI number for the interface. |
broadcast | (Optional) Broadcasts should be forwarded to this address when multicast is not enabled (see the frame-relay multicast-dlci command for more information about multicasts). This keyword also simplifies the configuration of OSPF. |
ietf | (Optional) IETF form of Frame Relay encapsulation. Use when the router is connected to another vendor's equipment across a Frame Relay network. |
cisco | (Optional) Cisco encapsulation method. |
frame-relay map bridge dlci [broadcast]
no frame-relay map bridge dlci
Use the frame-relay map bridge interface configuration command to specify that broadcasts should be forwarded when bridging. Use the no form of this command to delete the map entry.
dlci | DLCI number for the interface. |
broadcast | (Optional) Broadcasts should be forwarded to this address when multicast is not enabled. |
frame-relay map clns dlci [broadcast]
no frame-relay map clns dlci
Use the frame-relay map clns interface configuration command to specify that broadcasts should be forwarded when routing using ISO CLNS. Use the no form of this command to delete the map entry.
dlci | DLCI number for the interface. |
broadcast | (Optional) Broadcasts should be forwarded to this address when multicast is not enabled. |
frame-relay multicast-dlci number
no frame-relay multicast-dlci
Use the frame-relay multicast-dlci interface configuration command to define the DLCI to be used for multicasts. Use the no form of this command to remove the multicast group.
number | Multicast DLCI. (Note that this is not the multicast group number, which is an entirely different value.) |
[no] frame-relay route in-dlci out-interface out-dlci
Use the frame-relay route interface configuration command to specify the static route for PVC switching. Use the no form of this command to remove a static route.
in-dlci | DLCI on which the packet is received on the interface. |
out-interface | Interface the router uses to transmit the packet. |
out-dlci | DLCI the router uses to transmit the packet over the specified out-interface. |
Use the frame-relay switching global configuration command to enable PVC switching on a Frame Relay DCE or an NNI. Use the no form of this command to disable switching.
show frame-relay lmi [interface]
Use the show frame-relay lmi EXEC command to display statistics about the Local Management Interface (LMI).
interface | (Optional) LMI statistics for only the specified interface. |
Use the show frame-relay map EXEC command to display the current Frame Relay map entries and information about these connections.
show frame-relay pvc [interface [dlci]]
Use the show frame-relay pvc EXEC command to display statistics about PVCs for Frame Relay interfaces.
interface | (Optional) PVC statistics display for only the specified interface display. |
dlci | (Optional) DLCI number for the interface. Statistics for the specified PVC display when a DLCI is also specified. |
Use the show frame-relay route EXEC command to display all configured Frame Relay routes, along with their status.
Use the show frame-relay traffic EXEC command to display the router's global Frame Relay statistics since the last reload.
Use the show interfaces serial EXEC command to display information about a serial interface. When using the Frame Relay encapsulation, use the show interfaces serial command to display information on the multicast DLCI, the DLCI of the interface, and the LMI DLCI used for the Local Management Interface.
The multicast DLCI and the local DLCI can be set using the frame-relay multicast-dlci and the frame-relay local-dlci commands, or provided through the Local Management Interface. The status information is taken from the LMI, when active.
number | Interface number |
|