The SwitchProbe device is designed to operate in a standard office environment and can be placed on a table or mounted in an equipment rack near the network segment it serves. The site must be equipped with:
Warning This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure that a fuse or circuit breaker no larger than 120 VAC, 15A U.S. (240 VAC, 10A international) is used on the phase conductors (all current-carrying conductors). |
Warning Read the installation instructions before you connect the system to its power source. |
Warning This unit is intended for installation in restricted access areas. A restricted access area is where access can only be gained by service personnel through the use of a special tool, lock and key, or other means of security, and is controlled by the authority responsible for the location. |
Warning Do not work on the system or connect or disconnect cables during periods of lightning activity. |
Warning Hazardous network voltages are present in WAN ports regardless of whether power to the unit is OFF or ON. To avoid electric shock, use caution when working near WAN ports. When detaching cables, detach the end away from the unit first. |
Warning This equipment is to be installed and maintained by service personnel only as defined by AS/NZS 3260 Clause 1.2.14.3 Service Personnel. |
Warning The telecommunications lines must be disconnected 1) before unplugging the main power connector and/or 2) while the housing is open. |
Warning To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cord. |
Warning The device is designed to work with TN power systems. |