This document discusses the Cisco Network Management Support CD release and includes the following information:
In addition to this release note, use the CiscoView Release Note or the CiscoWorks Windows Release Note when installing and using CiscoView.
The Cisco Network Management Support CD now includes several new and updated Cisco devices that work with the CiscoView application. These devices are also available from the Cisco Connection Online (CCO) service. To mount and install devices from the support CD, refer to the special CD booklet included in your package. Be sure to read the README files on the Network Management Support CD or turn to the section "README Files for Device Support."
Caution Before installing CiscoView or CiscoView devices, read the caveats in your CiscoView or CiscoWorks Windows release note section "Installation Notes and Caveats." |
CiscoView consists of the CiscoView 3.1.1 product (also referred to as the CiscoView engine) and device support, plus the additional device support now found on the Network Management Support CD. If you already have release 3.1 installed, you do not need to reinstall release 3.2 (1). Only install the devices you need off the Network Management Support CD.
Table 1 lists the new or updated Cisco devices included on the Network Management Support CD. These devices are supported on all platforms unless otherwise noted.
Supported Operating Systems and Network Management Software | ||||||
---|---|---|---|---|---|---|
Cisco Device | Software Releases | SunOS/ Solaris and SNM1 | SunOS/ Solaris and HP OpenView2 | HP-UX and HP OpenView3 | NetView AIX4 | Windows 95 or NT3.5.1 |
765 and 766 | Cisco IOS 10.3, 11.0, and 11.1 | X | X | X | X | X |
CiscoPro 765 and 766 | Cisco IOS 10.3, 11.0, and 11.1 | X | X | X | X | X |
1003, 1004, and 1005 | Cisco IOS 10.3, 11.0, and 11.1 | X | X | X | X | X |
2520, 2521, 2522, 2523, 2524, 2525, 4000, 4000-M, 4500, 4500-M, 4700, 4700-M | Cisco IOS Software Release 10.0 to 11.1 (Releases 10.2 and 10.3 do not support all cards for the 4000 Series routers.) | X | X | X | X | X |
CiscoPro 4500 | Cisco IOS 11.1 through 11.3 | X | X | X | X | X |
CiscoPro 2520, 2522, 2524 | Cisco IOS 10.3, 11.0, and 11.1 | X | X | X | X | X |
AS5200 Universal Access Server | Cisco IOS 11.1(5) | SunOS 4.1.x (Solaris 1.x) | NA | HP-UX 9.0.4 HP OpenView 3.3 | NA | HP-UX 9.0.4 HP OpenView 3.3 |
7206 | Cisco IOS 11.1(5) | X | X | X | X | X |
Catalyst 1200 | Cisco Software Release 4.1 | X | X | X | X | X |
Catalyst 1600 | Cisco Software Release 11.1 | X | X | X | X | X |
Catalyst 1800 | Cisco Software Release TRX/FDU.2.1.10 | X | X | X | X | X |
Catalyst 2600 | Cisco Software Release SR-2.06 | X | X | X | X | X |
Catalyst 2900 | Cisco Software Release 2.1 | X | X | X | X | X |
Catalyst 3000 | Cisco Software Release 1.1, 1.2, and 1.3 | X | X | X | X | X |
Catalyst 5000 | Cisco Software Release 1.4, 1.5, and 2.1 | X | X | X | X | X |
CPW16 | Cisco Software Release 1.1 | X | X | X | X | X |
CPW1220, CPW1420, Cat1900, and Cat2820 | Cisco Software Release 1.0 | X | X | X | X | X |
CPW 2200 | Software Release 2.1 | X | X | X | X | X |
Grand Junction FastSwitch 2100 and 2800 | Sofware Release 3.62 | X | X | X | X | X |
EtherSwitch 10/100 and Catalyst 1700 | Software Release 1.38 | X | X | X | X | X |
Grand Junction FastSwitch 10/100 | Software Release 1.37 | X | X | X | X | X |
Catalyst 2100 and 2800, EtherSwitch 1200 and 1400 | Software Release 3.63 | X | X | X | X | X |
Fasthub 100+ and Netbeyond Fasthub 300 | Software Release 1.12 | X | X | X | X | X |
LS1010 | Software Release 11.1, IISP | X | X | X | X | X |
The following README files describe device support included on this release:
This ReadMe file includes the following sections:
* Introduction
* Devices supported
* Tar file (*.tar)
* MIB files
* CiscoView and CiscoWorks Windows releases
* Network management platforms
* Operating systems
* Cisco IOS-700 software releases
* Current documentation
* Caveats
INTRODUCTION ***************************************************************
The 760 series and CPA760 series routers provide professional offices,
small offices, and individuals with affordable, high-speed remote access to
networks and the Internet in a modem-sized package. The routers connect
Ethernet LANs to corporate networks over Integrated Services Digital
Network (ISDN) Basic Rate Interface (BRI) lines. They offer multiprotocol
routing between WAN and LAN ports, as well as transparent bridging.
DEVICES SUPPORTED **********************************************************
This incremental install includes support for the following routers:
* Cisco 761 and CPA761
* Cisco 762 and CPA762
* Cisco 765 and CPA765
* Cisco 766 and CPA766
TAR FILE *******************************************************************
The tar file (*.tar) includes the electronic network management device
package file (*.pkg) that enables you to view and manage the Cisco 760
series routers using CiscoView and CiscoWorks Windows. The tar file also
includes a copy of this ReadMe file.
MIB FILES ******************************************************************
Simple Network Management Protocol (SNMP) Management Information Base (MIB)
files are available for network management. The following Cisco Connection
Online (CCO) Web location contains many MIBs:
ftp://ftp-eng.cisco.com/pub/mibs/supportlists/as5200/supportlist.html
CISCOVIEW AND CISCOWORKS WINDOWS RELEASES **********************************
The supporting CiscoView release is CiscoView 3.1(1).
The supporting CiscoWorks Windows release is CiscoWorks Windows 2.0(1).
NETWORK MANAGEMENT PLATFORMS ***********************************************
The network management platforms supported are the same platforms that are
available for CiscoView 3.1(1) and CiscoWorks Windows 2.0(1):
* UNIX: Sun workstation: SunNet Manager 2.2.2
* UNIX: Sun workstation: Hewlett-Packard (HP) OpenView 3.3
* UNIX: HP system: HP OpenView (HPOV) for UNIX 3.3
* UNIX: HP OpenView (HPOV) with Solaris
* UNIX: SunNet Manager (SNM) with Solaris
* UNIX: Standalone HP-UX and Sun UNIX
* PC: HP OpenView for Windows 95 and Windows NT, Release 7.2b (C.02.17)
* PC: CastleRock SNMPc 4.1g with HP OpenView emulation support with
Windows 95 and Windows NT
* PC: Standalone Windows 95 and Windows NT
OPERATING SYSTEMS **********************************************************
The Cisco 760 series and CPA760 series router file (*.pkg)
runs on the same operating systems as CiscoView 3.1(1) and CiscoWorks
Windows 2.0(1):
* Sun running Solaris 1.x (SunOS 4.1.3, SunOS 4.1.3_U1, or SunOS 4.1.4), or
Solaris 2.4 with recommended patches as of 3/16/95
* HP running HP-UX A.09.03/A.09.04./A.09.05
* Windows 95 4.0
* Windows NT 3.51
CISCO IOS-700 SOFTWARE RELEASES ********************************************
Cisco IOS-700 Software Releases 3.2(2) and 3.2(4) support the Cisco 760
series and CPA760 series routers.
CURRENT DOCUMENTATION ******************************************************
Look for these documents on the Cisco Connection Documentation CD-ROMs:
Cisco 760 series and CPA760 series documentation:
* The router installation and configuration guide
* The router command reference
* Cisco ConnectPro User Guide
CiscoView and CiscoWorks Windows documentation:
* CiscoView 3.1.(1) Release Notes
* CiscoWorks Windows 2.0(1) Release Notes
* CiscoView CD Installation Instructions
* CiscoWorks Windows CD Installation Instructions
* CiscoWorks Windows Getting Started Guide
* Downloading New Cisco Devices and Applications (quick reference card)
CAVEATS ********************************************************************
1. The Cisco 760 series and CPA760 series routers do not support the SNMP
set operations.
2. No management support is available for the Config port (configure port)
option.
This ReadMe file includes the following sections:
* Introduction
* What's New
* Tar File (*.tar)
* CiscoView and CiscoWorks Windows Releases
* Network Management Platforms
* Operating Systems
* Cisco Internetwork Operating System (Cisco IOS) Software Releases
* Current Documentation
* Caveats
***************************************************************
INTRODUCTION
Cisco 1000 series routers are easy-to-install, inexpensive,
multiprotocol routers designed for small offices and other remote sites.
Cisco 1000 series routers include the following models:
Cisco 1003, CPA1003, Cisco 1004, CPA1004, Cisco 1005 and CPA1005.
***************************************************************
WHAT'S NEW
This release includes support for additional network management
platforms and operating systems, and support for the
Cisco CPA1003, CPA1004 and CPA1005.
*******************************************************************
TAR FILE
The tar file (*.tar) includes the electronic network management device
package file (*.pkg) that enables you to view and manage Cisco 1000
series routers using CiscoView and CiscoWorks Windows. The tar file
includes a copy of this ReadMe file.
********************************************************************
CISCOVIEW AND CISCOWORKS WINDOWS RELEASES
The supporting CiscoView release is CiscoView 3.1(1).
The supporting CiscoWorks Windows release is CiscoWorks Windows 2.0(1).
********************************************************************
NETWORK MANAGEMENT PLATFORMS
The network management platforms supported are the same platforms
as are available for CiscoView 3.1(1) and CiscoWorks Windows 2.0(1):
* UNIX: Sun workstation: SunNet Manager 2.2.2
* UNIX: Sun workstation: Hewlett-Packard (HP) OpenView (OV) 3.3
* UNIX: HP system: HP OpenView (HPOV) for UNIX 3.3
* UNIX: HP OpenView (HPOV) with Solaris
* UNIX: SunNet Manager (SNM) with Solaris
* UNIX: Standalone HP-UX and Sun UNIX
* AIX: NetView for AIX 3.1 or 4.1
* PC: HP OpenView (HPOV) for Windows 95 and Windows NT,
Release 7.2b (C.02.17)
* PC: CastleRock SNMPc 4.1g with HP OpenView (HPOV) emulation
support with Windows 95 and Windows NT
* PC: Standalone Windows 95 and Windows NT
********************************************************************
OPERATING SYSTEMS
The Cisco 1000 series device package file (*.pkg) runs on the same
operating systems as CiscoView 3.1(1) and CiscoWorks Windows 2.0(1):
* Sun running Solaris 1.x (SunOS 4.1.3, SunOS 4.1.3_U1, or SunOS 4.1.4),
or Solaris 2.4 with recommended patches as of 3/16/95
* HP running HP-UX A.09.03/A.09.04./A.09.05
* AIX, 3.2.5 or 4.1
* Windows 95 4.0
* Windows NT 3.51
********************************************************************
CISCO INTERNETWORK OPERATING SYSTEM (CISCO IOS) SOFTWARE RELEASES
Cisco IOS software Releases 10.3, 11.0 and 11.1 support Cisco 1000
series routers.
********************************************************************
CURRENT DOCUMENTATION
Look for these documents on the Documentation CD-ROM:
Cisco 1000 series documentation:
* Cisco 1003 and Cisco 1004 User Guide
* Cisco 1005 User Guide
* Cisco 1003 and Cisco 1004 Public Network Certification
* Cisco 1005 Public Network Certification
* Upgrading the DRAM SIMM in the Cisco 1003, 1004, and 1005
CiscoView and CiscoWorks Windows documentation:
* CiscoView 3.1.(1) Release Note
* CiscoView Incremental Installation Quick Reference
* CiscoView CD Installation Instructions
* CiscoWorks Windows 2.0(1) Release Note
* CiscoWorks Windows Incremental Installation Quick Reference
* CiscoWorks Windows CD Installation Instructions
* CiscoWorks Windows Getting Started Guide
********************************************************************
CAVEATS
None at this time.
This ReadMe file includes the following sections:
* Introduction
* Tar file (*.tar)
* MIB files
* CiscoView and CiscoWorks Windows releases
* Network management platforms
* Operating systems
* Cisco Internet Operating System (Cisco IOS) software release
* Current documentation
* Caveats
INTRODUCTION ***************************************************************
The Cisco 1600 series includes the Cisco 1601, CPA1601, Cisco 1602,
CPA1602, Cisco 1603, CPA1603, Cisco 1604, and CPA1604. The Cisco 1600
series is a family of small desktop routers that link remote-site Ethernet
LANs to regional and central offices over multiple WAN connections.
TAR FILE ******************************************************************
The tar file (*.tar) includes the electronic network management device
package file (*.pkg) that enables you to view and manage the Cisco 1600
using CiscoView and CiscoWorks Windows. The tar file also includes a copy
of this ReadMe file.
MIB FILES ******************************************************************
SNMP MIB files are available for network management. The following Cisco
Customer Connection Online (CCO) WEB location contains many MIBs:
ftp://ftp-eng.cisco.com/pub/mibs/supportlists/as5200/supportlist.html
CISCOVIEW AND CISCOWORKS WINDOWS RELEASES **********************************
The supporting CiscoView release is CiscoView 3.1(1).
The supporting CiscoWorks Windows release is CiscoWorks Windows 2.0(1).
NETWORK MANAGEMENT PLATFORMS ************************************************
The following are the supported operating system and network management
platform combinations:
* UNIX: Sun workstation: SunNet Manager 2.2.2
* UNIX: Sun workstation: Hewlett-Packard (HP) OpenView 3.3
* UNIX: HP system: HPOV (HP OpenView) for UNIX 3.3
* UNIX: HPOV with Solaris
* UNIX: SNM (SunNet Manager) with Solaris
* UNIX: Stand-alone HPUX and SUN UNIX
* AIX: NetView for AIX 3.1 or 4.1
* PC: HP OpenView for Windows 95 and Windows NT, 7.2b (C.02.17)
* PC: CastleRock SNMPc 4.1g with HP OpenView emulation support with
Windows 95 and Windows NT
* PC: Stand-alone Windows 95 and Windows NT
OPERATING SYSTEMS ***********************************************************
The Cisco 1600 device package file (*.pkg) currently runs on the same
operating systems as CiscoView 3.1(1) and CiscoWorks Windows 2.0(1):
* Sun running Solaris 1.x (SunOS 4.1.3, SunOS 4.1.3_U1, or SunOS 4.1.4), or
Solaris 2.4 with recommended patches as of 3/16/95
* HP running HP-UX A.09.03/A.09.04./A.09.05
* AIX, 3.2.5 or 4.1
* Windows 95 4.0
* Windows NT 3.51
CISCO IOS SOFTWARE RELEASE *************************************************
Cisco IOS software release 11.1 supports the Cisco 1600 series routers.
CURRENT DOCUMENTATION ******************************************************
Look for some of these documents on the Cisco Connection Documentation,
Enterprise Series CD-ROM. The quick reference cards are not on the CD-ROM.
Cisco 1600 documentation:
The following two documents ship with every model:
* Cisco 1600 Series Router Installation and Configuration Guide
* Regulatory Compliance and Safety Information for Cisco 1600 Series Routers
The following configuration notes ship with spares for the Cisco 1600
series routers:
* Installing an ISDN BRI S/T WAN Interface Card in Cisco 1600 Series Routers
* Installing an ISDN BRI U WAN Interface Card in Cisco 1600 Series Routers
* Replacing the DRAM SIMM in Cisco 1600 Series Routers
The following quick reference cards are listed by hardware model:
* Cisco 1601
-Start Here
-Connecting Your Cisco 1601
-ClickStart for Cisco 1600 Series Routers
-Required Information for Frame Relay
-Configuring Frame Relay
-Required Information for a Leased Line
-Configuring a Leased Line
* Cisco 1602
-Start Here
-Connecting Your Cisco 1602
-ClickStart for Cisco 1600 Series Routers
-Required Information for Frame Relay
-Configuring Frame Relay
-Required Information for a Leased Line
-Configuring a Leased Line
* Cisco 1603
-Start Here
-Connecting Your Cisco 1603
-ClickStart for Cisco 1600 Series Routers
-Required Information for ISDN
-Configuring ISDN
* Cisco 1604
-Start Here
-Connecting Your Cisco 1604
-ClickStart for Cisco 1600 Series Routers
-Required Information for ISDN
-Configuring ISDN
CiscoView documentation:
* CiscoView 3.1.(1) Release Note
* CiscoView Incremental Installation Quick Reference
* CiscoView CD Installation Instructions
CAVEATS********************************************************************
This section contains caveats about problems related to the Cisco 1600 that
might while using CiscoView.
#1.
ID #: CSCdi73863 -
All Cisco 1600 WAN interface cards return an 'Unknown card type 36x'
message in the Card Configuration dialog box. This is caused by a bug in
snmptcl. You can ignore this message.
#2.
The new categories for the ISDN-U port type also show up for other port
types when rewinding and forwarding the port configuration dialog from the
ISDN-U port. You can ignore this problem.
#3.
For a few help topics, the help text might display topic names with 2500,
4000, 7000, or 7500. This is because some of the help topics used in the
Cisco 1600 help file are shared with other help files. To return to the
Cisco 1600 help file, from the CiscoView Main window, select Help, then
Contents. Select the Cisco 1600.
This ReadMe file includes the following sections:
* Introduction
* Tar file (*.tar)
* MIB files
* Devices supported
* Network processor modules supported
* Network management platforms
* Operating systems
* Cisco Internet Operating System (Cisco IOS) software releases
* Current documentation
* Caveats
INTRODUCTION ****************************************************************
Cisco 4000, Cisco 4500, and Cisco 4700 series routers (including the Cisco
4000-M, Cisco 4500-M, and Cisco 4700-M) provide a variety of features that
can accommodate all types of network computing environments.
Cisco 2500 series routers are available in a variety of models for small
offices and remote site environments.
TAR FILE ********************************************************************
The tar file (*.tar) includes the electronic network management device
package file (*.pkg) that enables you to view and manage Cisco 4000, Cisco
4500, Cisco 4700, and Cisco 2500 series routers using CiscoView and
CiscoWorks Windows. The tar file also includes a copy of this ReadMe file.
MIB FILES *******************************************************************
SNMP MIB files are available for network management. The following Cisco
Connection Online (CCO) URL contains many MIBs:
ftp://ftp-eng.cisco.com/pub/mibs/supportlists/as5200/supportlist.html
DEVICES SUPPORTED ***********************************************************
This incremental installation includes support for the following devices:
* Cisco 4000-M
* Cisco 4500-M
* Cisco 4700
* Cisco 4700-M
* CPA4700
* Cisco 2520
* Cisco 2521
* Cisco 2522
* Cisco 2523
* Cisco 2524
* Cisco 2525
* CPA2501
* CPA2502
* CPA2503
* CPA2504
* CPA2505
* CPA2507
* CPA2509
* CPA2511
* CPA2513
* CPA2514
* CPA2516
* CPA2520
* CPA2521
* CPA2522
* CPA2523
* CPA2524
The basic version of CiscoView 3.1(1) and CiscoWorks Windows 2.0(1)
(without this incremental installation) includes support for the Cisco 4000
and Cisco 4500, and Cisco 2501 through Cisco 2516, except for the Cisco
2506 and Cisco 2508, which are not available.
NETWORK PROCESSOR MODULES SUPPORTED ******************************************
This incremental installation includes support for the following network
processor modules (npm):
* npm-4000-fddi-sas
* npm-4000-fddi-das
* npm-4000-1e
* npm-4000-1r
* npm-4000-2s
* npm-4000-2e1
* npm-4000-2e
* npm-4000-2r1
* npm-4000-2r
* npm-4000-4t
* npm-4000-4b
* npm-4000-8b
* npm-4000-ct1
* npm-4000-ce1
* npm-4000-1a
* npm-4000-6e
* npm-4000-1fe
NETWORK MANAGEMENT PLATFORMS ************************************************
The network management platforms supported are the same platforms that are
available for CiscoView 3.1(1) and CiscoWorks Windows 2.0(1):
* Sun workstation: SunNet Manager 2.2.2
* Sun workstation: Hewlett-Packard (HP) OpenView 3.3
* HP system: HP OpenView for UNIX 3.3
* PC: HP OpenView for Windows, 7.2b (C.02.17)
* PC: CastleRock SNMPc 4.1g with HP OpenView emulation support
See CAVEATS at the end of this ReadMe for important information regarding
HP OpenView for Windows.
OPERATING SYSTEMS ************************************************************
The Cisco 4000, Cisco 4500, Cisco 4700, and Cisco 2500 series device
package (*.pkg) currently runs on the same operating systems as CiscoView
3.1(1) and CiscoWorks Windows 2.0(1):
* Sun running Solaris 1.x (SunOS 4.1.3, SunOS 4.1.3_U1, or SunOS 4.1.4), or
Solaris 2.4 with recommended patches as of 3/16/95
* HP running HP-UX A.09.03/A.09.04./A.09.05
* Windows 95 4.0
* Windows NT 3.51
CISCO IOS SOFTWARE RELEASES *************************************************
Cisco IOS Software Release 11.1 and earlier releases support Cisco 4000,
Cisco 4500, Cisco 4700, and Cisco 2500 series routers.
Note: Cisco IOS Releases 10.2 and 10.3 do not support all cards for the
Cisco 4000 series routers. All Cisco 4000 series routers are supported in
Cisco IOS Release 11.0 and later releases.
CURRENT DOCUMENTATION *******************************************************
Look for these documents on the Cisco Connection Documentation, Enterprise
Series CD-ROM:
Cisco 4000 series documentation:
Cisco 4000 Series Installation Guide
(use for Cisco 4000-M, Cisco 4500-M, Cisco 4700-M)
Cisco 4000 Series Hardware Installation and Maintenance
(use for Cisco 4700)
Cisco 4000 Hardware Installation and Maintenance
(use for Cisco 4000 and Cisco 4500)
Cisco 4000 series configuration notes:
Upgrading Memory in the Cisco 4000 and Cisco 4000-M
Upgrading the Cisco 4000 Flash EPROM Card (Cisco 4000)
Installing Network Processor Modules in the Cisco 4000 Series
Cisco 4000 Series Rack-Mount and Wall-Mount Installation
Upgrading System Software in the Cisco 4000 Series
Connecting the Cisco 4000 DC-Input Power Supply
Upgrading Cisco 4500, Cisco 4500-M, Cisco 4700, and Cisco 4700-M Memory
Upgrading the Flash EPROM Memory Card (Cisco 4000)
Cisco 2500 series documentation:
Cisco 2500 Series Router Installation Guide
(Cisco 2501-2504 and Cisco 2513-2515)
Cisco 2500 Series Hardware Installation and Maintenance
(Cisco 2505, Cisco 2507, Cisco 2516)
Cisco 2500 Series Hardware Installation
(Cisco 2505, Cisco 2507, Cisco 2516)
Cisco 2500 Series Access Server User Guide
(Cisco 2509, Cisco 2510, Cisco 2511, Cisco 2512)
Cisco 2517 and Cisco 2519 Router/Hub User Guide
Cisco 2518 Router/Hub User Guide
Cisco 2500 Series Multiport Serial Router User Guide
(Cisco 2520, Cisco 2521, Cisco 2522, Cisco 2523)
Cisco 2524 and Cisco 2525 Router User Guide
Cisco 2500 series configuration notes:
- Upgrading the DRAM SIMM on the Cisco 2500 Series Routers
- Replacing the Boot ROMs in the Cisco 2500 Series and AccessPro PC Card
- Installing Dual Flash Memory SIMMs on the Cisco 2500 Series
- Upgrading Boot Image with Flash Memory Cards for Cisco 2500 Series Routers
- Upgrading Feature Sets with Flash Cards for Cisco 2500 Series Routers
CiscoView and CiscoWorks Windows documentation:
* CiscoView 3.1.(1) Release Note
* CiscoView Incremental Installation Quick Reference
* CiscoView CD Installation Instructions
* CiscoWorks Windows 2.0(1) Release Note
* CiscoWorks Windows Incremental Installation Quick Reference
* CiscoWorks Windows CD Installation Instructions
* CiscoWorks Windows Getting Started Guide
CAVEATS**********************************************************************
Note: Caveats 1 through 4 apply only to Cisco 2500 series routers:
1. The Cisco 2520, Cisco 2521, Cisco 2522, and Cisco 2523 routers had a bug
in the agent implementation that affected CiscoView. This bug was fixed in
Cisco IOS Release 11.0(5) and 11.1(2.1). For CiscoView to work properly,
these routers must have a Cisco IOS Release 11.0(5.1) and 11.1(2.1) or
later.
2. Cisco 2524 and Cisco 2525 routers have an extra MIB for the two CSU/DSU
WAN cards. This MIB is implemented only in Cisco IOS Release 11.0(5). These
routers can be viewed properly only if they have Cisco IOS Release 11.0(5)
or later.
3. Cisco 2524 and Cisco 2525 routers have two CSU/DSU WAN card slots. Each
of the slots can contain any one of the following cards:
* Two-wire switched 56K/64K
* Four-wire switched 56K/64K
* Fractional T1
* 5-in-1 serial
* Empty
Because of a bug in the MIB agent implementation, there is no way to
distinguish between the 5-in-1 card in a slot and an empty slot. In both
cases, CiscoView displays the 5-in-1 card gif. (The gif is the viewable
picture of the device and cards.)
4. Cisco 2524 and Cisco 2525 routers have a BRI card slot, which can
contain either a BRI card with an NT1 interface or a BRI card without an
NT1 interface. At present, there is no way to differentiate between these
two cards using the MIB. In both cases, CiscoView displays the BRI card
without the NT1 gif.
5. The following Cisco Access devices require the current version of HP
OpenView for Windows, version 7.2b (C.02.17):
Device Name: Tar Filename:
* CPA2520, CPA2522, CPA2524 2500.cv311.Px-x.tar
* CPA4500 4000.cv311.Px-x.tar
Previously we notified you of a problem with HP OpenView for Windows, 7.2b
(C.02.14), where CiscoView did not recognize the Access devices listed
above. HP fixed this problem. The fix for this problem requires that you
upgrade HP OpenView for Windows and run a conversion utility for any of the
affected device packages you might have installed.
HP OpenView for Windows must be upgraded (first to C.02.15, then to
C.02.17) to work with the above devices. For details on upgrading HP
OpenView for Windows and running the required conversion utility, refer to
the CiscoWorks Release Note, version 2.1(1).
This ReadMe file includes the following sections:
* Introduction
* Tar file (*.tar)
* MIB files
* CiscoView and CiscoWorks Windows releases
* Network management platforms
* Operating systems
* Cisco Internet Operating System (Cisco IOS) software release
* Current documentation
* Caveats
INTRODUCTION ***************************************************************
The Cisco 3600 series includes the Cisco 3640, CPA3640, Cisco 3620, and
CPA3620. The Cisco 3640 and CPA3640 are four-slot Access routers aimed at
high-powered branch offices and small to midsize regional offices. The
Cisco 3620 and CPA3620 are two slot routers for small branch offices.
The Cisco 3600 series have interchangeable modules and WAN interface cards.
The modular design provides flexibility.
TAR FILE ******************************************************************
The tar file (*.tar) includes the electronic network management device
package file (*.pkg) that enables you to view and manage the Cisco 3600
using CiscoView and CiscoWorks Windows. The tar file also includes a copy
of this ReadMe file.
MIB FILES ******************************************************************
SNMP MIB files are available for network management. The following Cisco
Customer Connection Online (CCO) WEB location contains many MIBs:
ftp://ftp-eng.cisco.com/pub/mibs/supportlists/as5200/supportlist.html
CISCOVIEW AND CISCOWORKS WINDOWS RELEASES **********************************
The supporting CiscoView release is CiscoView 3.1(1).
The supporting CiscoWorks Windows release is CiscoWorks Windows 2.0(1).
NETWORK MANAGEMENT PLATFORMS ************************************************
The following are the supported operating system and network management
platform combinations:
* UNIX: Sun workstation: SunNet Manager 2.2.2
* UNIX: Sun workstation: Hewlett-Packard (HP) OpenView 3.3
* UNIX: HP system: HPOV (HP OpenView) for UNIX 3.3
* UNIX: HPOV with Solaris
* UNIX: SNM (SunNet Manager) with Solaris
* UNIX: Stand-alone HPUX and SUN UNIX
* AIX: NetView for AIX 3.1 or 4.1
* PC: HP OpenView for Windows 95 and Windows NT, 7.2b (C.02.17)
* PC: CastleRock SNMPc 4.1g with HP OpenView emulation support with
Windows 95 and Windows NT
* PC: Stand-alone Windows 95 and Windows NT
OPERATING SYSTEMS ***********************************************************
The Cisco 3600 device package file (*.pkg) currently runs on the same
operating systems as CiscoView 3.1(1) and CiscoWorks Windows 2.0(1):
* Sun running Solaris 1.x (SunOS 4.1.3, SunOS 4.1.3_U1, or SunOS 4.1.4), or
Solaris 2.4 with recommended patches as of 3/16/95
* HP running HP-UX A.09.03/A.09.04./A.09.05
* AIX, 3.2.5 or 4.1
* Windows 95 4.0
* Windows NT 3.51
CISCO IOS SOFTWARE RELEASE *************************************************
Cisco IOS software release 11.1 supports the Cisco 3600 series routers.
CURRENT DOCUMENTATION ******************************************************
Look for these documents on the Cisco Connection Documentation, Enterprise
Series CD-ROM.
Cisco 3600 documentation:
* Cisco 3620 Installation and Configuration Guide
* Cisco 3640 Installation and Configuration Guide
* Regulatory Compliance and Safety Information
Cisco 3600 configuration notes:
* 1-Port and 2-Port ISDN-PRI Network Module Configuration Note
* WAN Card Slot Network Module Configuration Note
* Cisco 3600 Series Rack-Mount and Wall-Mount Configuration Note
* Upgrading Cisco 3600 Series Memory Configuration Note
* Cisco 3600 Series Power Supply Configuration Note
* Installing and Configuring Flash Memory Cards in Cisco 3600 Series Routers
* 1-Port Serial WAN Interface Card Configuration Note
* 1-Port ISDN-BRI WAN Interface Card Configuration Note
* 4-Port and 8-Port ISDN-BRI Network Module Configuration Note
* 4-Port and 8-Port Asynchronous/Synchronous Seial Network Module
CiscoView and CiscoWorks Windows documentation:
* CiscoView 3.1.(1) Release Notes
* CiscoWorks Windows 2.0(1) Release Notes
* CiscoView CD Installation Instructions
* CiscoWorks Windows CD Installation Instructions
* CiscoWorks Windows Getting Started Guide
* Downloading New Cisco Devices and Applications (quick reference card)
CAVEATS********************************************************************
This section contains caveats about problems related to the Cisco 3600 that
might while using CiscoView.
#1.
ID #: CSCdi69480 -
For the T1/E1 ports, the configuration popup window shows only the ds1
configuration information. Interface information for these ports is not
shown. This is due to a bug in the agent implementation.
#2.
ID #: CSCdi73863 -
Some of the configuration popup windows for the port modules and daughter
cards show an error message "Unknown Card Type: xxx," where xxx is an
integer. This is caused by a problem with the CiscoView engine
(specifically snmpTcl). The error message means that CiscoView could not
translate the integer value xxx for the cardType MIB variable (obtained
from the router) into the enumeration defined in the chassis MIB.
11/25/96
ReadMe File:
Update to CiscoView 3.1(1) and CiscoWorks Windows 2.0(1)--
Cisco 4000, Cisco 4500, Cisco 4700, and Cisco 2500 Series Incremental
Installation
This ReadMe file includes the following sections:
* Introduction
* Tar file (*.tar)
* MIB files
* Devices supported
* Network processor modules supported
* Network management platforms
* Operating systems
* Cisco Internet Operating System (Cisco IOS) software releases
* Current documentation
* Caveats
INTRODUCTION ****************************************************************
Cisco 4000, Cisco 4500, and Cisco 4700 series routers (including the Cisco
4000-M, Cisco 4500-M, and Cisco 4700-M) provide a variety of features that
can accommodate all types of network computing environments.
Cisco 2500 series routers are available in a variety of models for small
offices and remote site environments.
TAR FILE ********************************************************************
The tar file (*.tar) includes the electronic network management device
package file (*.pkg) that enables you to view and manage Cisco 4000, Cisco
4500, Cisco 4700, and Cisco 2500 series routers using CiscoView and
CiscoWorks Windows. The tar file also includes a copy of this ReadMe file.
MIB FILES *******************************************************************
SNMP MIB files are available for network management. The following Cisco
Connection Online (CCO) URL contains many MIBs:
ftp://ftp-eng.cisco.com/pub/mibs/supportlists/as5200/supportlist.html
DEVICES SUPPORTED ***********************************************************
This incremental installation includes support for the following devices:
* Cisco 4000-M
* Cisco 4500-M
* Cisco 4700
* Cisco 4700-M
* CPA4700
* Cisco 2520
* Cisco 2521
* Cisco 2522
* Cisco 2523
* Cisco 2524
* Cisco 2525
* CPA2501
* CPA2502
* CPA2503
* CPA2504
* CPA2505
* CPA2507
* CPA2509
* CPA2511
* CPA2513
* CPA2514
* CPA2516
* CPA2520
* CPA2521
* CPA2522
* CPA2523
* CPA2524
The basic version of CiscoView 3.1(1) and CiscoWorks Windows 2.0(1)
(without this incremental installation) includes support for the Cisco 4000
and Cisco 4500, and Cisco 2501 through Cisco 2516, except for the Cisco
2506 and Cisco 2508, which are not available.
NETWORK PROCESSOR MODULES SUPPORTED ******************************************
This incremental installation includes support for the following network
processor modules (npm):
* npm-4000-fddi-sas
* npm-4000-fddi-das
* npm-4000-1e
* npm-4000-1r
* npm-4000-2s
* npm-4000-2e1
* npm-4000-2e
* npm-4000-2r1
* npm-4000-2r
* npm-4000-4t
* npm-4000-4b
* npm-4000-8b
* npm-4000-ct1
* npm-4000-ce1
* npm-4000-1a
* npm-4000-6e
* npm-4000-1fe
NETWORK MANAGEMENT PLATFORMS ************************************************
The network management platforms supported are the same platforms that are
available for CiscoView 3.1(1) and CiscoWorks Windows 2.0(1):
* Sun workstation: SunNet Manager 2.2.2
* Sun workstation: Hewlett-Packard (HP) OpenView 3.3
* HP system: HP OpenView for UNIX 3.3
* AIX system: NetView for AIX 3.1 or 4.1
* PC: HP OpenView for Windows, 7.2b (C.02.17)
* PC: CastleRock SNMPc 4.1g with HP OpenView emulation support
See CAVEATS at the end of this ReadMe for important information regarding
HP OpenView for Windows.
OPERATING SYSTEMS ************************************************************
The Cisco 4000, Cisco 4500, Cisco 4700, and Cisco 2500 series device
package (*.pkg) currently runs on the same operating systems as CiscoView
3.1(1) and CiscoWorks Windows 2.0(1):
* Sun running Solaris 1.x (SunOS 4.1.3, SunOS 4.1.3_U1, or SunOS 4.1.4), or
Solaris 2.4 with recommended patches as of 3/16/95
* HP running HP-UX A.09.03/A.09.04./A.09.05
* AIX, 3.2.5 or 4.1
* Windows 95 4.0
* Windows NT 3.51
CISCO IOS SOFTWARE RELEASES *************************************************
Cisco IOS Software Release 11.1 and earlier releases support Cisco 4000,
Cisco 4500, Cisco 4700, and Cisco 2500 series routers.
Note: Cisco IOS Releases 10.2 and 10.3 do not support all cards for the
Cisco 4000 series routers. All Cisco 4000 series routers are supported in
Cisco IOS Release 11.0 and later releases.
CURRENT DOCUMENTATION *******************************************************
Look for these documents on the Cisco Connection Documentation, Enterprise
Series CD-ROM:
Cisco 4000 series documentation:
Cisco 4000 Series Installation Guide
(use for Cisco 4000-M, Cisco 4500-M, Cisco 4700-M)
Cisco 4000 Series Hardware Installation and Maintenance
(use for Cisco 4700)
Cisco 4000 Hardware Installation and Maintenance
(use for Cisco 4000 and Cisco 4500)
Cisco 4000 series configuration notes:
Upgrading Memory in the Cisco 4000 and Cisco 4000-M
Upgrading the Cisco 4000 Flash EPROM Card (Cisco 4000)
Installing Network Processor Modules in the Cisco 4000 Series
Cisco 4000 Series Rack-Mount and Wall-Mount Installation
Upgrading System Software in the Cisco 4000 Series
Connecting the Cisco 4000 DC-Input Power Supply
Upgrading Cisco 4500, Cisco 4500-M, Cisco 4700, and Cisco 4700-M Memory
Upgrading the Flash EPROM Memory Card (Cisco 4000)
Cisco 2500 series documentation:
Cisco 2500 Series Router Installation Guide
(Cisco 2501-2504 and Cisco 2513-2515)
Cisco 2500 Series Hardware Installation and Maintenance
(Cisco 2505, Cisco 2507, Cisco 2516)
Cisco 2500 Series Hardware Installation
(Cisco 2505, Cisco 2507, Cisco 2516)
Cisco 2500 Series Access Server User Guide
(Cisco 2509, Cisco 2510, Cisco 2511, Cisco 2512)
Cisco 2517 and Cisco 2519 Router/Hub User Guide
Cisco 2518 Router/Hub User Guide
Cisco 2500 Series Multiport Serial Router User Guide
(Cisco 2520, Cisco 2521, Cisco 2522, Cisco 2523)
Cisco 2524 and Cisco 2525 Router User Guide
Cisco 2500 series configuration notes:
- Upgrading the DRAM SIMM on the Cisco 2500 Series Routers
- Replacing the Boot ROMs in the Cisco 2500 Series and AccessPro PC Card
- Installing Dual Flash Memory SIMMs on the Cisco 2500 Series
- Upgrading Boot Image with Flash Memory Cards for Cisco 2500 Series Routers
- Upgrading Feature Sets with Flash Cards for Cisco 2500 Series Routers
CiscoView and CiscoWorks Windows documentation:
* CiscoView 3.1.(1) Release Note
* CiscoView Incremental Installation Quick Reference
* CiscoView CD Installation Instructions
* CiscoWorks Windows 2.0(1) Release Note
* CiscoWorks Windows Incremental Installation Quick Reference
* CiscoWorks Windows CD Installation Instructions
* CiscoWorks Windows Getting Started Guide
CAVEATS**********************************************************************
Note: Caveats 1 through 4 apply only to Cisco 2500 series routers:
1. The Cisco 2520, Cisco 2521, Cisco 2522, and Cisco 2523 routers had a bug
in the agent implementation that affected CiscoView. This bug was fixed in
Cisco IOS Release 11.0(5) and 11.1(2.1). For CiscoView to work properly,
these routers must have a Cisco IOS Release 11.0(5.1) and 11.1(2.1) or
later.
2. Cisco 2524 and Cisco 2525 routers have an extra MIB for the two CSU/DSU
WAN cards. This MIB is implemented only in Cisco IOS Release 11.0(5). These
routers can be viewed properly only if they have Cisco IOS Release 11.0(5)
or later.
3. Cisco 2524 and Cisco 2525 routers have two CSU/DSU WAN card slots. Each
of the slots can contain any one of the following cards:
* Two-wire switched 56K/64K
* Four-wire switched 56K/64K
* Fractional T1
* 5-in-1 serial
* Empty
Because of a bug in the MIB agent implementation, there is no way to
distinguish between the 5-in-1 card in a slot and an empty slot. In both
cases, CiscoView displays the 5-in-1 card gif. (The gif is the viewable
picture of the device and cards.)
4. Cisco 2524 and Cisco 2525 routers have a BRI card slot, which can
contain either a BRI card with an NT1 interface or a BRI card without an
NT1 interface. At present, there is no way to differentiate between these
two cards using the MIB. In both cases, CiscoView displays the BRI card
without the NT1 gif.
5. The following Cisco Access devices require the current version of HP
OpenView for Windows, version 7.2b (C.02.17):
Device Name: Tar Filename:
* CPA2520, CPA2522, CPA2524 2500.cv311.Px-x.tar
* CPA4500 4000.cv311.Px-x.tar
Previously we notified you of a problem with HP OpenView for Windows, 7.2b
(C.02.14), where CiscoView did not recognize the Access devices listed
above. HP fixed this problem. The fix for this problem requires that you
upgrade HP OpenView for Windows and run a conversion utility for any of the
affected device packages you might have installed.
HP OpenView for Windows must be upgraded (first to C.02.15, then to
C.02.17) to work with the above devices. For details on upgrading HP
OpenView for Windows and running the required conversion utility, refer to
the CiscoWorks Release Note, version 2.1(1).
12/2/96 7000.cv311.P3-0
CiscoView 3.1 Release Note Update for the Cisco 7000 Router Family.
This readme file provides information about the Cisco Router 7000
incremental device support package version 3.1(3.0). This package
supports the Cisco 7000, 7200, and 7500 Series Routers and replaces
the 7000 package version 3.1(2.1).
This readme file contains the following sections:
* P3-0 package contents
* Package Tar File
* CiscoView Release
* Operating System
* Current Documentation
* Caveats
* P2-1 package readme text
P3-0 PACKAGE CONTENTS *****************************************************
This package contains new device support, new functionality, and
several bug fixes.
New Device Support:
-------------------
* Cisco 7204 router
* 7200 IO Card (without FE port)
* CT3 Interface Processor card
* Port Adapter cards
o SA-Compression
o PA-FDDI-MM-FD
o PA-FDDI-SM-FD
o PA-H1T
o PA-H2T
o PA-4T
o PA-8T-V35
New Functionality:
------------------
* Flash File System Admin functionality for CiscoView on Windows NT
systems (previously available only on Unix systems)
* Cisco Compression Service Adapter MIB
o SA-Compression Card Configure/Monitor categories
- Card Configuration (Compression Enabled/Disabled)
- Compression Statistics
* Cisco IP Encryption MIB
o Three new Device Configure software encryption categories:
- Encryption Configuration
- Encryption Engine Status Table
- Encryption Connection Table
* Enable/Normal LEDs on port adapters, interface processors, route
processors (on routers running IOS version 11.1 or later)
o LEDs are shown as green (on) or black (off) to simulate
their appearance on the card.
* Power Supply LEDs on 7000, 72xx, 7507, 7513
Bug Fixes:
----------
* Possibly misleading LED displays [CSCdi62760]
* Poll for FDDI i/f SMT index [CSCdi62971]
* Flash file size information is not updated [CSCdi63120]
* Bad ifTable causes display problems [CSCdi66033]
* 7010 SNM component record missing in P2-0 [CSCdi72507]
* Incorrect utilization formula [CSCdi73927]
* Incomplete device redraw after OIR event [CSCdi75019]
PACKAGE TAR FILE *****************************************************
The tar file, 7000.cv311.P3-0.tar, includes the electronic network
management package file, 7000.pkg, that provides the support listed
above. It also includes a copy of this readme file.
CISCOVIEW RELEASE ****************************************************
The CiscoView releases that support this package are CiscoView 3.1(1)
and CiscoView 3.2(1) for Unix and the PC.
OPERATING SYSTEM *****************************************************
This package runs on all OS/NMS platform combinations that support
CiscoView 3.1(1) and 3.2(1).
CURRENT DOCUMENTATION ************************************************
- CiscoView 3.2(1) Release Notes
- CiscoView CD Installation Instructions
- Downloading New Cisco Devices and Applications (quick reference card)
CAVEATS***************************************************************
The following problems may be encountered while using this new package:
* FEIP and FE port adapters now display port status only on the
configured connector. The other connector will appear gray.
* Flash File System functions:
- Functions may fail if the host system hostname is not in DNS.
- If a "Squeeze" operation fails, try increasing the timeout property
under Options on the Main window. The proper timeout value may
vary according to network utilization.
- To copy IOS image files with tftp format filenames (e.g.,
patch/rsp-jv-mz.1028) from the local filesystem, be sure that the
corresponding directory already exists on the remote file system.
- The "Delete" function will fail if the RW community string is not
properly set on the router or in CiscoView.
* With the introduction of the 7200, SunNet Manager and HP OpenView
network map icons identify a Cisco 7xxx router according to its
family, i.e., 7000, 7200, or 7500. Icons no longer specifically
identify the 7000 or 7010 routers. For SNMPc and OpenView Windows
a "7000" icon is used for all 7x00 router families.
* CT3 IP support in this package is limited to card-level configuration
data. No port specific data is available and the displayed connectors
will remain gray (no status).
* This package supports a new TN3270 Monitor program. The program
itself is scheduled to be available in mid-December 1996 on CCO as a
separately downloadable/installable package.
* All cards in a chassis containing a SA-Compression card will offer a
Card Monitor category, even though this category applies only to the
SA-Compression card. Invoking the Card Monitor category on another
card type results in a "monitors not available" message. [CSCdi74396]
* Public Key field may overlap other fields of the Encryption Engine
Status Table on Windows platforms. [CSCdi75662]
* Selecting Card Configure for a card displayed as an "Unknown Card"
gives a Tcl script error. [CSCdi76091]
ReadMe File:
Update to CiscoView 3.1(1) and CiscoWorks Windows 2.0(1)--
Cisco AS5200 Universal Access Server Incremental Install: Release 2.0
This ReadMe file includes the following sections:
* Introduction
* What's new
* Tar file (*.tar)
* MIB files
* CiscoView and CiscoWorks Windows releases
* Network management platforms
* Operating system
* Cisco Internetwork Operating System (Cisco IOS) release
* AS5200 Manager application
* Current documentation
* Caveats
* Installation
INTRODUCTION **************************************************************
The Cisco AS5200 is a versatile data communications platform that provides
the functions of an access server, a router, and digital modems in a
modular chassis.
WHAT'S NEW ***************************************************************
Release 2.0 includes bug fixes, support for additional network management
platforms and operating systems, and support for the channelized E1/PRI
card.
TAR FILE *****************************************************************
The tar file (*.tar) includes the electronic network management device
package file (*.pkg) that enables you to display and manage the Cisco
AS5200 using CiscoView and CiscoWorks Windows. The tar file also includes a
copy of this ReadMe file.
MIB FILES ****************************************************************
Simple Network Management Protocol (SNMP) Management Information Base (MIB)
files are available for network management.
AS5200 supports all MIBs that IOS supports, plus the Cisco Modem MIB that was
first implemented in AS5200.
The following Cisco Connection Online (CCO) URL contains many MIBs:
ftp://ftp-eng.cisco.com/pub/mibs/supportlists/as5200/supportlist.html
CISCOVIEW AND CISCOWORKS WINDOWS RELEASES *********************************
The supporting CiscoView release is CiscoView 3.1(1).
The supporting CiscoWorks Windows release is CiscoWorks Windows 2.0(1).
NETWORK MANAGEMENT PLATFORMS **********************************************
The network management platforms supported are the same platforms that are
available for CiscoView 3.1(1) and CiscoWorks Windows 2.0(1):
* UNIX: Sun workstation: SunNet Manager 2.2.2
* UNIX: Sun workstation: Hewlett-Packard (HP) OpenView 3.3
* UNIX: HP system: HP OpenView (HPOV) for UNIX 3.3
* UNIX: HP OpenView (HPOV) with Solaris
* UNIX: SunNet Manager (SNM) with Solaris
* UNIX: Standalone HP-UX and Sun UNIX
* AIX: NetView for AIX 3.1 or 4.1
* PC: HP OpenView for Windows 95 and Windows NT, Release 7.2b (C.02.17)
* PC: CastleRock SNMPc 4.1g with HP OpenView emulation support with
Windows 95 and Windows NT
* PC: Standalone Windows 95 and Windows NT
OPERATING SYSTEMS *********************************************************
The Cisco AS5200 device package file (*.pkg) runs on the same operating
systems as CiscoView 3.1(1) and CiscoWorks Windows 2.0(1):
* Sun running Solaris 1.x (SunOS 4.1.3, SunOS 4.1.3_U1, or SunOS 4.1.4), or
Solaris 2.4 with recommended patches as of 3/16/95
* HP running HP-UX A.09.03/A.09.04./A.09.05
* AIX, 3.2.5 or 4.1
* Windows 95 4.0
* Windows NT 3.51
CISCO IOS RELEASE ********************************************************
Cisco IOS Release 11.1(5) supports the Cisco AS5200.
AS5200 MANAGER APPLICATION ***********************************************
The Cisco AS5200 package includes the AS5200 Manager application. The
AS5200 Manager application includes modem management, and enables you to
remotely view, monitor, configure, and troubleshoot the AS5200 Universal
Access Server from within CiscoView.
CURRENT DOCUMENTATION ****************************************************
Look for the following documents on the Cisco Connection Documentation,
Enterprise Series CD-ROM:
Cisco AS5200 documentation:
* Cisco AS5200 Universal Access Server Installation Guide
* Cisco AS5200 Universal Access Server Software Configuration Guide
* 12-Port Modem AT Command Set and Register Summary
* Cisco AS5200 Universal Access Server Installation Quick Reference Card
* Cisco AS5200 Universal Access Server Configuration Quick Reference Card
* Cisco AS5200 Safety and Regulatory Compliance
* Cisco AS5200 Terminator Card Installation Note
* AS5200 Manager Guide (available only online on CCO)
CiscoView documentation:
* CiscoView 3.1.(1) Release Note
* CiscoView Incremental Installation Quick Reference
* CiscoView CD Installation Instructions
CAVEATS *******************************************************************
The following problems might occur while using CiscoView.
#1.
ID #: CSCdi68740 -
This release contains bug CSCdi68740, which causes devinst.exe to refuse to
reinstall the package (pkg) file in the Windows platform. The work around
is to use the CiscoWorks Windows Uninstall Device option to uninstall the
AS5200 pkg file, and then use the CiscoWorks Windows Install Device option
to reinstall the AS5200 pkg file.
#2.
ID #: CSCdi73863 -
Some of the configuration popup windows for the port modules and daughter
cards show an error message "Unknown Card Type: xxx," where xxx is an
integer. This is caused by a problem with the CiscoView engine
(specifically snmpTcl). The error message means that CiscoView could not
translate the integer value xxx for the cardType MIB variable (obtained
from the router) into the enumeration defined in the chassis MIB.
INSTALLATION *************************************************************
This section is divided into two parts:
* Installing on a UNIX Workstation quick reference
* Installing on a PC quick reference
Refer to the AS5200 Manager Guide on Cisco Connection Online (CCO) for
installation details. To access the guide, enter the following URL:
http://oracular/ucdrt/data/doc/hardware/access/5200/5200.htm
For details on downloading to a UNIX workstation, see Chapter 2 of the
AS5200 Manager Guide.
For details on downloading to a PC, see Chapter 3 of the AS5200 Manager Guide.
************ INSTALLING ON A UNIX WORKSTATION QUICK REFERENCE ************
If you are installing on a UNIX workstation, you can access the Cisco
AS5200 device package file in two ways: from Cisco Connection Online (CCO),
or by using the anonymous FTP service. Chapter 2 of the AS5200 Manager
Guide contains detail about both ways. A quick reference follows.
+++ DOWNLOADING FROM CISCO CONNECTION ONLINE (CCO) +++
[1] Check the version of CiscoView.
[2] Close CiscoView.
[3] Create a cv_pkgs directory in the install_directory on your workstation.
[4] Change the default directory to cv_pkgs.
[5] Access CCO.
[6] Download the tar file onto your workstation.
[7] Untar the tar file.
[8] Add the package file to CiscoView.
[9] Check the cvinstall.log file.
Details about the above steps are in the AS5200 Manager Guide.
+++ USING ANONYMOUS FTP TO DOWNLOAD THE TAR FILE +++
[1] Check the version of CiscoView.
[2] Close CiscoView.
[3] Create a cv_pkgs directory in the install_directory on your workstation.
[4] Change the default directory to cv_pkgs.
[5] Download the tar file into the cv_pkgs directory on your workstation.
[6] Untar the tar file.
[7] Add the package file to CiscoView.
[8] Check the cvinstall.log file.
Details about the above steps are in the AS5200 Manager Guide.
******************** INSTALLING ON A PC QUICK REFERENCE *******************
If you are installing on a PC, you can access the Cisco AS5200 device
package file from Cisco Connection Online (CCO). Chapter 3 of the AS5200
Manager Guide contains detail. A quick reference follows.
[1] Check the version number of CiscoView and CiscoWorks Windows.
[2] Close CiscoView.
[3] Create a cv_pkgs directory in the CWW directory on your PC.
[4] Access CCO.
[5] Download the tar file into the cv_pkgs directory.
[6] Unzip the tar file.
[7] Add the package file to CiscoView.
[8] View your device.
[9] Optionally, delete the cv_pkgs directory.
Details about the above steps are in the AS5200 Manager Guide.
This ReadMe file describes the Cisco Catalyst 1200 device
package, and associated:
* network management platforms
* operating systems
* current documentation available
* caveats, if any
NETWORK MANAGEMENT PLATFORMS
The network management platforms are the same platforms available for
CiscoView 3.1(1) and CiscoWorks Windows 2.0(1):
* On a Sun workstation: SunNet Manager, 2.2.2
* On a Sun workstation: Hewlett-Packard (HP) OpenView, 3.3
* On an HP system: HP OpenView, 3.3
* On a PC: HP OpenView for Windows, 7.2b (C.02.14 or 2.14)
* On a PC: CastleRock SNMPc, 4.1g with HP OpenView emulation support
OPERATING SYSTEMS
The Cisco Catalyst 1200 device package currently runs on the
same operating systems as CiscoView 3.1(1) and CiscoWorks Windows 2.0(1):
* Sun running Solaris 1.x (SunOS 4.1.3, SunOS 4.1.3_U1, or SunOS 4.1.4),
or Solaris 2.4 with recommended patches as of 3/16/95
* HP running HP-UX A.09.03/A.09.04./A.09.05
* Windows 95, 4.0
* Windows NT, 3.51
CISCO SOFTWARE RELEASES
Cisco software release 4.1 for the Catalyst 1200
NEW FEATURES
This device package extends the CiscoView device manager to include support for:
* CDP (Cisco Discovery Protocol) configuration
* VTP (VLAN Trunk Prootocol) configuration
* CiscoView launch of Traffic Director for RMON capable switches
CURRENT DOCUMENTATION AVAILABLE
* CiscoView 3.1.(1) Release Note
* CiscoWorks Windows 2.0(1) Release Note
* CiscoView CD Installation Instructions
* CiscoWorks Windows CD Installation Instructions
* CiscoWorks Windows Getting Started Guide
* Downloading New Cisco Devices and Applications (quick reference card)
CAVEATS
Please refer to the "Release notes for CWSI UNIX Version 1.0", Document
Number 78-3337; for additional information about CiscoView 3.1 and
Traffic Director.
If CiscoView 3.1.1 is installed on an HP OpenView platform, theCiscoView
application will query and use the device's community name settings from
HPOV, whether CiscoView is launched from the command line or from the
HPOV main menu. When this is done through HPOV, any further standalone
invocation of CiscoView will take the community string from HPOV until
the nmcview script exports the platform.
The IP Route device configuration window is not scrollable. Use the
numbered arrow keys to scroll the window.
When using the Switch Zoom menu from CiscoView to view multiple switch
ports, the default configuration for the Catalyst 1200 is to configure
Statistics, Short-Term history, Long-Term history, and Host group.
For the Catalyst 5000, the default configuration is to configure
Statistics only. To see the short-term or long-term history from
traffic monitor, use the Domain Manager to configure the short-term
and long-term group manually or use Segment Zoom to view the port first.
When using the Segment Zoom menu from CiscoView to view the port
segment, the default configuration for the Catalyst 1200 is to configure
the Statistics, Short-Term history, Long-Term history and Host group.
For the Catalyst 5000 it is Statistics, Short-Term history, and
Long-Term history.
If you get the "Error: Entry or Group not present in Agent" message when
invoking Segment Zoom, Switch Zoom, or Data Capture, the write community
string may not be matched with the device. If the community string is
matched and the problem still happens, use the CiscoView Configure
Device menu to see if the RMON capability is enabled or not.
When you select the repeater module port on a Catalyst 5000, it always
uses the first port of the selected segment to create the RMON agent
group. If you see "IP address is not set in sysIpAddr Mib variable,"
it is because the Catalyst 1200 SNMP agent does not store the correct
IP address in the sysIpAddr MIB variable, so you have to use CiscoView
to correct it. Go to Configure>Device, enter the correct IP address
in the corresponding field, and click Modify.
12/16/96
CiscoView 3.1(1) and CiscoWorks Windows -- Incremental Install for the Cisco
Catalyst 1800 Device Package [version 1.0]
This README file includes the following sections:
* Introduction
* Network Management platforms
* Operating Systems
* CISCO Catalyst 1800 SYSTEM SOFTWARE RELEASES
* Tar file (*.tar)
* Current documentation available
* Caveats, if any
* Changes from the earlier release of the package
INTRODUCTION
The Catalyst 1800 Token Ring Switch is a token ring, packet-switching device
that dramatically increases performance, flexibility, and management on token
ring installations.
NETWORK MANAGEMENT PLATFORMS
The Network Management platforms are the same platforms available for
CiscoView 3.1(1) and CiscoWorks Windows 2.0(1):
* On a Sun workstation: SunNet Manager, 2.2.3
* On a Sun workstation: Hewlett-Packard (HP) OpenView, 3.3
* On an HP system: HP OpenView, 3.3
* On an AIX system: NetView 3.1 or NetView 4.1
* On a PC: HP OpenView for Windows, 7.2b (C.02.14 or 2.14)
* On a PC: CastleRock SNMPc, 4.1g with HP OpenView emulation support
OPERATING SYSTEMS
1. SUN running Solaris 1.x (SunOS 4.1.3, SunOS 4.1.3_UI, or SunOS 4.1.4), or
Solaris 2.4 with recommended patches as of 3/16/95
2. HP running HP-UX A.09.03/A.09.04/A.09.05
3. AIX 3.2.5(1) or 4.1
4. Windows 95 4.0
5. Windows NT 3.51
CISCO Catalyst 1800 SYSTEM SOFTWARE RELEASES
This package is compatible with System Firmware Version TRX/FDU.2.1.10 or
above.
TAR FILE
The tar file (*.tar) includes the electronic network management device package
file (*.pkg) that enables you to view and manage Catalyst 1800 using CiscoView
and CiscoWorks Windows. The tar file also contains a copy of this README file.
Files available from the Network Management Support CD are not in the .tar
format and do need not be untarred.
CURRENT DOCUMENTATION AVAILABLE
* Catalyst 1800 Token Ring Switch User Guide
* Catalyst 1800 Token Ring Switch FDU module Installation Guides
* Catalyst 1800 Token Ring Switch Customer Release Notes
* CiscoView 3.1.(1) Release Note
* CiscoView Incremental Installation Quick Reference
* CiscoView 3.1 (1) CD Installation Instructions
* CiscoWorks Windows 2.0(1) Release Note
* CiscoWorks Windows Incremental Installation Quick Reference
* CiscoWorks Windows CD Installation Instructions
* CiscoWorks Windows Getting Started Guide
CAVEATS
1. The device agent does not update the IP Address Table of MIB-II properly
and does not reflect the correct IP Address information of all the device
interfaces. So, the user will not be able to view the correct IP Address
information of the device through Device->Configure->IP Address Table.
2. The user will not be able to create new static entries for IP Route Table
and ARP Table through CiscoView.
3. In the interface configuration (Port->Config->Interface), modification of
the IP parameters always results in an error message being displayed, but
the modification is done successfully.
4. The user will not be able to change the bridge type of the FDDI port to
sr-only or srt.
5. The user will not be able to change the bridge type of the TR port to
srtb or tb-only.
6. The system time configuration is not included as part of device
configuration.
CHANGES FROM THE EARLIER (BETA) RELEASE
1. In the VLAN Configuration, the user can create the VLANs by specifying the
logical segment numbers and/or physical port numbers.
This ReadMe file describes the Cisco CPW16 device
package, and associated:
* network management platforms
* operating systems
* current documentation available
* caveats, if any
NETWORK MANAGEMENT PLATFORMS
The network management platforms are the same platforms available for
CiscoView 3.1(1) and CiscoWorks Windows 2.0(1):
* On a Sun workstation: SunNet Manager, 2.2.2
* On a Sun workstation: Hewlett-Packard (HP) OpenView, 3.3
* On an HP system: HP OpenView, 3.3
* On a PC: HP OpenView for Windows, 7.2b (C.02.14 or 2.14)
* On a PC: CastleRock SNMPc, 4.1g with HP OpenView emulation support
OPERATING SYSTEMS
The Cisco CPW16 device package currently runs on the
same operating systems as CiscoView 3.1(1) and CiscoWorks Windows 2.0(1):
* Sun running Solaris 1.x (SunOS 4.1.3, SunOS 4.1.3_U1, or SunOS 4.1.4),
or Solaris 2.4 with recommended patches as of 3/16/95
* HP running HP-UX A.09.03/A.09.04./A.09.05
* Windows 95, 4.0
* Windows NT, 3.51
CISCO SOFTWARE RELEASES
Cisco software release 1.1 for the CPW16.
NEW FEATURES
This device package extends the CiscoView device manager to include:
* Support for CDP configuration
CURRENT DOCUMENTATION AVAILABLE
* CiscoView 3.1.(1) Release Note
* CiscoWorks Windows 2.0(1) Release Note
* CiscoView CD Installation Instructions
* CiscoWorks Windows CD Installation Instructions
* CiscoWorks Windows Getting Started Guide
* Downloading New Cisco Devices and Applications (quick reference card)
CAVEATS
Please refer to the "Release notes for CWSI UNIX Version 1.0", Document
Number 78-3337; for additional information about CiscoView 3.1 and
Traffic Director.
If CiscoView 3.1.1 is installed on an HP OpenView platform, theCiscoView
application will query and use the device's community name settings from
HPOV, whether CiscoView is launched from the command line or from the
HPOV main menu. When this is done through HPOV, any further standalone
invocation of CiscoView will take the community string from HPOV until
the nmcview script exports the platform.
The IP Route device configuration window is not scrollable. Use the
numbered arrow keys to scroll the window.
This ReadMe file describes the Cisco CPW1220, CPW1420,
Cat1900, and Cat2820 device packages, and associated:
* network management platforms
* operating systems
* current documentation available
* caveats, if any
NETWORK MANAGEMENT PLATFORMS
The network management platforms are the same platforms available for
CiscoView 3.1(1) and CiscoWorks Windows 2.0(1):
* On a Sun workstation: SunNet Manager, 2.2.2
* On a Sun workstation: Hewlett-Packard (HP) OpenView, 3.3
* On an HP system: HP OpenView, 3.3
* On a PC: HP OpenView for Windows, 7.2b (C.02.14 or 2.14)
* On a PC: CastleRock SNMPc, 4.1g with HP OpenView emulation support
OPERATING SYSTEMS
These device packages currently runs on the
same operating systems as CiscoView 3.1(1) and CiscoWorks Windows 2.0(1):
* Sun running Solaris 1.x (SunOS 4.1.3, SunOS 4.1.3_U1, or SunOS 4.1.4),
or Solaris 2.4 with recommended patches as of 3/16/95
* HP running HP-UX A.09.03/A.09.04./A.09.05
* Windows 95, 4.0
* Windows NT, 3.51
CISCO SOFTWARE RELEASES
The switches must be running software release 1.0 or later.
NEW FEATURES
These new device packages extends the CiscoView device manager to support
management of Cisco EtherSwitch 1220, EtherSwitch 1420, Catalyst 1900,
and Catalyst 2820.
CURRENT DOCUMENTATION AVAILABLE
* CiscoView 3.1.(1) Release Note
* CiscoWorks Windows 2.0(1) Release Note
* CiscoView CD Installation Instructions
* CiscoWorks Windows CD Installation Instructions
* CiscoWorks Windows Getting Started Guide
* Downloading New Cisco Devices and Applications (quick reference card)
CAVEATS
In the front panel display of the Cat 2820 and CPW 1420, the Connect
and Disabled LEDs on FDDI modules do not reflect the appropriate
status.
CPW 1420, Cat 2820-Do not attempt to invoke the Monitoring menu for an FDDI
port or a repeater port. There is no monitoring function provided for these
ports, although the pull-down menu is enabled when such ports are selected.
CPW 1420, Cat 2820-The Configure Module Windows do not work when more than
one module type is selected. Select only one module type before opening
these windows.
CPW 1220, CPW 1420, Cat 1900, Cat 2820-The General Bridge window shows the
bridge information for VLAN1 only. Bridge information for other VLANs is
not available.
CPW 1220, CPW 1420, Cat 1900, Cat 2820-The Spanning Tree Protocol Window
for switched ports is available for ports in VLAN1 only. This window does
not show valid information for ports not in VLAN1.
These packages do not show version information in the About CiscoView
dialog box. In these cases, the CiscoView About dialog box displays
the package version only. However, the version information is displayed
in the "Packages Installed" list.
Changes from Cisco CPW2200.cv311.1-1:
- Minor modification to the CISCO-STACK-MIB; no functional change.
This ReadMe file describes the Cisco CPW2200 device
package, and associated:
* network management platforms
* operating systems
* current documentation available
* caveats, if any
NETWORK MANAGEMENT PLATFORMS
The network management platforms are the same platforms available for
CiscoView 3.1(1) and CiscoWorks Windows 2.0(1):
* On a Sun workstation: SunNet Manager, 2.2.2
* On a Sun workstation: Hewlett-Packard (HP) OpenView, 3.3
* On an HP system: HP OpenView, 3.3
* On a PC: HP OpenView for Windows, 7.2b (C.02.14 or 2.14)
* On a PC: CastleRock SNMPc, 4.1g with HP OpenView emulation support
OPERATING SYSTEMS
The CiscoPro 2200 device package currently runs on the
same operating systems as CiscoView 3.1(1) and CiscoWorks Windows 2.0(1):
* Sun running Solaris 1.x (SunOS 4.1.3, SunOS 4.1.3_U1, or SunOS 4.1.4),
or Solaris 2.4 with recommended patches as of 3/16/95
* HP running HP-UX A.09.03/A.09.04./A.09.05
* Windows 95, 4.0
* Windows NT, 3.51
CISCO SOFTWARE RELEASES
Cisco software releases 2.1 for the Cisco CPW2200.
NEW FEATURES
This device package extends the CiscoView device manager to include support for:
* CDP (Cisco Discovery Protocol) configuration
* VTP (VLAN Trunk Prootocol) configuration
* CiscoView launch of Traffic Director for RMON capable switches
* WS-X5020: 48 port 10BaseT Group Switching Ethernet Module
* WS-X5011: 12 port 10Base FL module
* WS-X5213: 12 port 10/100 Base TX module
CURRENT DOCUMENTATION AVAILABLE
* CiscoView 3.1.(1) Release Note
* CiscoWorks Windows 2.0(1) Release Note
* CiscoView CD Installation Instructions
* CiscoWorks Windows CD Installation Instructions
* CiscoWorks Windows Getting Started Guide
* Downloading New Cisco Devices and Applications (quick reference card)
CAVEATS
Please refer to the "Release notes for CWSI UNIX Version 1.0", Document
Number 78-3337; for additional information about CiscoView 3.1 and Traffic
Director.
If CiscoView 3.1.1 is installed on an HP OpenView platform, the CiscoView
application will query and use the device's community name settings from
HPOV, whether CiscoView is launched from the command line or from the
HPOV main menu. When this is done through HPOV, any further standalone
invocation of CiscoView will take the community string from HPOV until
the nmcview script exports the platform.
The IP Route device configuration window is not scrollable. Use the
numbered arrow keys to scroll the window.
Under a heavy load condition, CiscoPro 2200 SNMP responses are slow.
You may see an "error, no response since...." message in the
CiscoView status window. Select Options>Properties and increase
the Polling Frequency and Timeout values. [CSCdi57962]
Do not use the Grapher in the CiscoView Monitor "10BaseT Group Switching
Ethernet" window. Use the Monitor or Traffic Director tools to see
graphical views of the selected repeater ports.
The embedded RMON agent in the CiscoPro 2200 only supports the Ethernet
Statistics and Ethernet History Groups. Data Capture and Host List do
not work on the CiscoPro 2200.
For the CiscoPro 2200, if the number of the embedded RMON agent is
over 50,you cannot create any new embedded RMON agent group for
the new port. Use the Domain Manager to deinstall the agent group
from the unused port to free the memory resource.
When you select the repeater module port on a CiscoPro 2200, it always
uses the first port of the selected segment to create the RMON agent
group. If you see "IP address is not set in sysIpAddr Mib variable,"
it is because the Catalyst 1200 SNMP agent does not store the correct
IP address in the sysIpAddr MIB variable, so you have to use CiscoView
to correct it. Go to Configure>Device, enter the correct IP address
in the corresponding field, and click Modify.
This ReadMe file describes the Cisco Catalyst 2600 device
package, and associated:
* network management platforms
* operating systems
* current documentation available
* Changes for the release, if any
NETWORK MANAGEMENT PLATFORMS
The network management platforms are the same platforms available for
CiscoView 3.1(1) and CiscoWorks Windows 2.0(1):
* On a Sun workstation: SunNet Manager, 2.2.3
* On a Sun workstation: Hewlett-Packard (HP) OpenView, 3.3
* On an HP system: HP OpenView, 3.3
* On a PC: HP OpenView for Windows, 7.2b (C.02.14 or 2.14)
* On a PC: CastleRock SNMPc, 4.1g with HP OpenView emulation support
OPERATING SYSTEMS
The Cisco Catalyst 2600 device package currently runs on the
same operating systems as CiscoView 3.1(1) and CiscoWorks Windows 2.0(1):
* Sun running Solaris 1.x (SunOS 4.1.3, SunOS 4.1.3_U1, or SunOS 4.1.4),
or Solaris 2.4 with recommended patches as of 3/16/95
* HP running HP-UX A.09.03/A.09.04./A.09.05
* Windows 95, 4.0
* Windows NT, 3.51
CISCO Catalyst 2600 SYSTEM SOFTWARE RELEASES
This package has been verified with system software version SR-2.0.6 and SR-2.2.1.
CURRENT DOCUMENTATION AVAILABLE
* Catalyst 2600 Token Ring Switch User Guide
* 2-Port Token Ring Fiber Universal Feature Card Planning and
Installation Guide
* 4-Port Token Ring UTP/STP Universal Feature Card Planning and
Installation Guide
* CiscoView 3.1.(1) Release Note
* CiscoWorks Windows 2.0(1) Release Note
* CiscoView CD Installation Instructions
* CiscoWorks Windows CD Installation Instructions
* CiscoWorks Windows Getting Started Guide
* Downloading New Cisco Devices and Applications (quick reference card)
CHANGES FOR THE RELEASE
1. The device package contains two versions of the enterprise mibs for Catalyst 2600 switch.
C2600_cisc.my -- This mib file is installed to support devices with
image versions prior to 2.2.1.
C2600.my -- This mib file is installed to support devices with
image version 2.2.1 or later.
When the user is using a MIB browser tool, he will see the mib
variables defined in each of the above, under different branches,
at the same time, though any particular Catalyst 2600 switch will
respond to queries on only one of the mibs based upon the release of
software in the device. Cisco recommends that you upgrade your Catalyst 2600
switches to version 2.2.1 or later.
Update to CiscoView 3.1(1) -- Incremental Install for the Cisco Catalyst
2900 Device Package
Changes from Cat 2900.cv311.1-1:
- Minor modification to the CISCO-STACK-MIB; no functional change.
This ReadMe file describes the Cisco Catalyst 2900 device
package, and associated:
* network management platforms
* operating systems
* current documentation available
* caveats, if any
NETWORK MANAGEMENT PLATFORMS
The network management platforms are the same platforms available for
CiscoView 3.1(1) and CiscoWorks Windows 2.0(1):
* On a Sun workstation: SunNet Manager, 2.2.2
* On a Sun workstation: Hewlett-Packard (HP) OpenView, 3.3
* On an HP system: HP OpenView, 3.3
* On an AIX system: NetView for AIX 3.1 or 4.1
* On a PC: HP OpenView for Windows, 7.2b (C.02.14 or 2.14)
* On a PC: CastleRock SNMPc, 4.1g with HP OpenView emulation support
OPERATING SYSTEMS
The Cisco Catalyst 2900 device package currently runs on the
same operating systems as CiscoView 3.1(1) and CiscoWorks Windows 2.0(1):
* Sun running Solaris 1.x (SunOS 4.1.3, SunOS 4.1.3_U1, or SunOS 4.1.4),
or Solaris 2.4 with recommended patches as of 3/16/95
* HP running HP-UX A.09.03/A.09.04./A.09.05
* Windows 95, 4.0
* Windows NT, 3.51
CISCO SOFTWARE RELEASES
Cisco software releases 2.1 for the Catlyst 2900.
NEW FEATURES
This device package extends the CiscoView device manager to include support for:
* CDP (Cisco Discovery Protocol) configuration
* VTP (VLAN Trunk Prootocol) configuration
* CiscoView launch of Traffic Director for RMON capable switches
* WS-X5020: 48 port 10BaseT Group Switching Ethernet Module
* WS-X5011: 12 port 10Base FL module
* WS-X5213: 12 port 10/100 Base TX module
CURRENT DOCUMENTATION AVAILABLE
* CiscoView 3.1.(1) Release Note
* CiscoWorks Windows 2.0(1) Release Note
* CiscoView CD Installation Instructions
* CiscoWorks Windows CD Installation Instructions
* CiscoWorks Windows Getting Started Guide
* Downloading New Cisco Devices and Applications (quick reference card)
CAVEATS
Please refer to the "Release notes for CWSI UNIX Version 1.0", Document
Number 78-3337; for additional information about CiscoView 3.1 and Traffic
Director.
If CiscoView 3.1.1 is installed on an HP OpenView platform, the CiscoView
application will query and use the device's community name settings from
HPOV, whether CiscoView is launched from the command line or from the
HPOV main menu. When this is done through HPOV, any further standalone
invocation of CiscoView will take the community string from HPOV until
the nmcview script exports the platform.
The IP Route device configuration window is not scrollable. Use the
numbered arrow keys to scroll the window.
Under a heavy load condition, Catalyst 2900 SNMP responses are slow.
You may see an "error, no response since...." message in the
CiscoView status window. Select Options>Properties and increase
the Polling Frequency and Timeout values. [CSCdi57962]
Do not use the Grapher in the CiscoView Monitor "10BaseT Group Switching
Ethernet" window. Use the Monitor or Traffic Director tools to see
graphical views of the selected repeater ports.
The embedded RMON agent in the Catalyst 2900 only supports the Ethernet
Statistics and Ethernet History Groups. Data Capture and Host List do
not work on the Catalyst 2900.
For the Catalyst 2900, if the number of the embedded RMON agent is
over 50,you cannot create any new embedded RMON agent group for
the new port. Use the Domain Manager to deinstall the agent group
from the unused port to free the memory resource.
When you select the repeater module port on a Catalyst 2900, it always
uses the first port of the selected segment to create the RMON agent
group. If you see "IP address is not set in sysIpAddr Mib variable,"
it is because the Catalyst 1200 SNMP agent does not store the correct
IP address in the sysIpAddr MIB variable, so you have to use CiscoView
to correct it. Go to Configure>Device, enter the correct IP address
in the corresponding field, and click Modify.
This device package extends the CiscoView device manager to include:
* VTP/VLAN configuration
* ATM LANE LEC configuration
* Support for WS-X3011 router blade
***************************IMPORTANT*********************************
This package supports the WS-X3011 router blade. This router is a
2500 series router and is managed by the 2500.pkg. For this release
the 2500.pkg *MUST* be installed before the Cat3000.pkg. If this step
is not followed, the Cat3000.pkg will fail to install.
*********************************************************************
NETWORK MANAGEMENT PLATFORMS
The network management platforms are the same platforms available for
CiscoView 3.1(1) and CiscoWorks Windows 2.0(1):
* On a Sun workstation: SunNet Manager, 2.2.2
* On a Sun workstation: Hewlett-Packard (HP) OpenView, 3.3
* On an HP system: HP OpenView, 3.3
* On an AIX system: NetView 3.2.1 or 4.1
* On a PC: HP OpenView for Windows, 7.2b (C.02.14 or 2.14)
* On a PC: CastleRock SNMPc, 4.1g with HP OpenView emulation support
OPERATING SYSTEMS
The Cisco Catalyst 3000 device package currently runs on the
same operating systems as CiscoView 3.1(1) and CiscoWorks Windows 2.0(1):
* Sun running Solaris 1.x (SunOS 4.1.3, SunOS 4.1.3_U1, or SunOS 4.1.4),
or Solaris 2.4 with recommended patches as of 3/16/95
* HP running HP-UX A.09.03/A.09.04./A.09.05
* AIX, 3.2.5 and 4.1
* Windows 95, 4.0
* Windows NT, 3.51
CISCO SOFTWARE RELEASES
The following firmware versions are supported:
CPW1601 v. 2.0
Catalyst 3000 v. 1.0, 1.1, 1.3, 2.0
Catalyst 3200 v. 1.0, 1.1, 1.3, 2.0
MIB FILES
Check Cisco Connection Online at the following URL for published
MIBs for this product: ftp://ftp-eng.cisco.com/pub/mibs/supportlists
TAR FILES
The following .tar file contains the ".pkg" file for the
Catalyst 3000: Cat3000.cv311.2-0.tar
DEVICES SUPPORTED
* CPW16
* Catalyst 3000
* Catalyst 3200
NETWORK PROCESSOR MODULES SUPPORTED
* WS-X3011
CURRENT DOCUMENTATION AVAILABLE
* CiscoView 3.1.(1) Release Note
* CiscoWorks Windows 2.0(1) Release Note
* CWSI 1.1 Release Notes
* CiscoView CD Installation Instructions
* CiscoWorks Windows CD Installation Instructions
* CiscoWorks Windows Getting Started Guide
* Downloading New Cisco Devices and Applications (quick reference card)
CAVEATS
Due to restriction in the CiscoView 3.1 engine, when the Catalyst 3200
is viewed using CiscoView it does not follow the traditional "real life"
display model for CiscoView device support. The display shows all
Catalyst 3200 modules compacted into a two slot chasis, with module
numbers increasing from left to right and top to bottom.
When changing the setting for Full/Half duplex on an ISL port the
change is not always reported correctly. This is due to a problem
in the Catalyst 3000 2.0 software and will be rectified in the next
release. [CSCdi74294]
When accessing a stack with six or more devices, there may be some
significant performance problems. The performance can be improved
by increasing the SNMP timeout settings.
It is not possible to drag and drop a port to a VLAN which does not
already have ports associated with it. This is due to a problem in
the Catalyst 3000 2.0 software and will be rectified in the next
release. For this release, use the CLI on the Cat3000 to assign the
first port to a VLAN. [CSCdi77035]
The Catalyst 3000 software does not support RMON on either a stack or
an ATM port.
The coloring of ports on the router module according to port status
is not supported in this release. If you wish to manage the router
module, use the right mouse button and select the "CiscoView Router"
menu then use the left mouse button to launch another CiscoView
session to manage the router.
The Catalyst 3000 software does not allow the modification of the
Parent VLAN number. [CSCdi76775]
The SAID value entered when creating an FDDI VLAN is redisplayed
as a different value. The VLAN was however created with the correct
value. This is due to a bug in the Catalyst 2.0 software and will
be rectified in the the next release.
Update to CiscoView 3.1(1) -- Incremental Install for the Cisco Catalyst
5000 Device Package
Changes from the Cat5000.cv311.1-1 version:
- Minor modifcations to the CISCO-STACK-MIB; no functional changes.
- bug fixes CSCdi60318, CSCdi65210, CSCdi64581
- Enhancement to the bitmap for the 100BaseTX module100BaseT
This ReadMe file describes the Cisco Catalyst 5000 device
package, and associated:
* network management platforms
* operating systems
* current documentation available
* caveats, if any
NETWORK MANAGEMENT PLATFORMS
The network management platforms are the same platforms available for
CiscoView 3.1(1) and CiscoWorks Windows 2.0(1):
* On a Sun workstation: SunNet Manager, 2.2.2
* On a Sun workstation: Hewlett-Packard (HP) OpenView, 3.3
* On an HP system: HP OpenView, 3.3
* On an AIX system: NetView for AIX 3.1 or 4.1
* On a PC: HP OpenView for Windows, 7.2b (C.02.14 or 2.14)
* On a PC: CastleRock SNMPc, 4.1g with HP OpenView emulation support
OPERATING SYSTEMS
The Cisco CAtalyst 5000 device package currently runs on the
same operating systems as CiscoView 3.1(1) and CiscoWorks Windows 2.0(1):
* Sun running Solaris 1.x (SunOS 4.1.3, SunOS 4.1.3_U1, or SunOS 4.1.4),
or Solaris 2.4 with recommended patches as of 3/16/95
* HP running HP-UX A.09.03/A.09.04./A.09.05
* AIX, 3.2.5 and 4.1
* Windows 95, 4.0
* Windows NT, 3.51
CISCO SOFTWARE RELEASES
Cisco software releases 1.4, 1.5 and 2.1 for the Catlyst 5000.
NEW FEATURES
This device package extends the CiscoView device manager to include support for:
* CDP (Cisco Discovery Protocol) configuration
* VTP (VLAN Trunk Prootocol) configuration
* CiscoView launch of Traffic Director for RMON capable switches
* WS-X5020: 48 port 10BaseT Group Switching Ethernet Module
* WS-X5005: NMP with 2 port 100Base FX SingleMode fiber
* WS-X5006: NMP with 2 port 100Base FX MultiMode fiber
* WS-X5011: 12 port 10Base FL module
* WS-X5213: 12 port 10/100 Base TX module
CURRENT DOCUMENTATION AVAILABLE
* CiscoView 3.1.(1) Release Note
* CiscoWorks Windows 2.0(1) Release Note
* CiscoView CD Installation Instructions
* CiscoWorks Windows CD Installation Instructions
* CiscoWorks Windows Getting Started Guide
* Downloading New Cisco Devices and Applications (quick reference card)
CAVEATS
Please refer to the "Release notes for CWSI UNIX Version 1.0", Document
Number 78-3337; for additional information about CiscoView 3.1 and
Traffic Director.
If CiscoView 3.1.1 is installed on an HP OpenView platform, theCiscoView
application will query and use the device's community name settings from
HPOV, whether CiscoView is launched from the command line or from the
HPOV main menu. When this is done through HPOV, any further standalone
invocation of CiscoView will take the community string from HPOV until
the nmcview script exports the platform.
The IP Route device configuration window is not scrollable. Use the
numbered arrow keys to scroll the window.
Under a heavy load condition, Catalyst 5000 SNMP responses are slow. You
may see an "error, no response since...." message in the CiscoView
status window. Select Options>Properties and increase the Polling
Frequency and Timeout values. [CSCdi57962]
Do not use the Grapher in the CiscoView Monitor "10BaseT Group Switching
Ethernet" window. Use the Monitor or Traffic Director tools to see
graphical views of the selected repeater ports.
The embedded RMON agent in the Catalyst 5000 only supports the Ethernet
Statistics and Ethernet History Groups. Data Capture and Host List do
not work on the Catalyst 5000.
When using the Switch Zoom menu from CiscoView to view multiple switch
ports, the default configuration for the Catalyst 1200 is to configure
Statistics, Short-Term history, Long-Term history, and Host group.
For the Catalyst 5000, the default configuration is to configure
Statistics only. To see the short-term or long-term history from
traffic monitor, use the Domain Manager to configure the short-term
and long-term group manually or use Segment Zoom to view the port
first.
When using the Segment Zoom menu from CiscoView to view the port
segment, the default configuration for the Catalyst 1200 is to
configure the Statistics, Short-Term history, Long-Term history
and Host group. For the Catalyst 5000 it is Statistics, Short-Term
history, and Long-Term history.
If you get the "Error: Entry or Group not present in Agent" message when
invoking Segment Zoom, Switch Zoom, or Data Capture, the write community
string may not be matched with the device. If the community string is
matched and the problem still happens, use the CiscoView Configure
Device menu to see if the RMON capability is enabled or not.
For the Catalyst 5000, if the number of the embedded RMON agent is over
50, you cannot create any new embedded RMON agent group for the new port.
Use the Domain Manager to deinstall the agent group from the unused port
to free the memory resource.
When you select the repeater module port on a Catalyst 5000, it always
uses the first port of the selected segment to create the RMON agent
group. If you see "IP address is not set in sysIpAddr Mib variable,"
it is because the Catalyst 1200 SNMP agent does not store the correct
IP address in the sysIpAddr MIB variable, so you have to use CiscoView
to correct it. Go to Configure>Device, enter the correct IP address
in the corresponding field, and click Modify.
This ReadMe file describes the Cisco CPW10-100, CPW1200, CPW1400,
Cat1700, Cat2100, Cat2800 device packages, and associated:
* network management platforms
* operating systems
* current documentation available
* caveats, if any
NETWORK MANAGEMENT PLATFORMS
The network management platforms are the same platforms available for
CiscoView 3.1(1) and CiscoWorks Windows 2.0(1):
* On a Sun workstation: SunNet Manager, 2.2.2
* On a Sun workstation: Hewlett-Packard (HP) OpenView, 3.3
* On an HP system: HP OpenView, 3.3
* On an AIX system: NetView for AIX 3.1 or 4.1
* On a PC: HP OpenView for Windows, 7.2b (C.02.14 or 2.14)
* On a PC: CastleRock SNMPc, 4.1g with HP OpenView emulation support
OPERATING SYSTEMS
These device packages currently runs on the
same operating systems as CiscoView 3.1(1) and CiscoWorks Windows 2.0(1):
* Sun running Solaris 1.x (SunOS 4.1.3, SunOS 4.1.3_U1, or SunOS 4.1.4),
or Solaris 2.4 with recommended patches as of 3/16/95
* HP running HP-UX A.09.03/A.09.04./A.09.05
* AIX, 3.2.5 or 4.1
* Windows 95, 4.0
* Windows NT, 3.51
CISCO SOFTWARE RELEASES
The following firmware versions are required:
Catalyst 2100 and 2800 v. 3.63 or higher
EtherSwitch 1200 and 1400 v. 3.63 or higher
Grand Junction FastSwitch 2100 and 2800 v. 3.62 or higher
NOTE: The Grand Junction FastSwitch 2100 and 2800 are managed the same as
the Catalyst 2100 and 2800 respectively.
EtherSwitch 10/100 v. 1.38 or higher
Catalyst 1700 v. 1.38 or higher
Grand Junction FastSwitch 10/100 v. 1.37 or higher
NEW FEATURES
These device packages extend the CiscoView device manager to include:
* Display of port status colors for Cisco EtherSwitch 10/100,
EtherSwitch 1200, EtherSwitch 1400, Catalyst 1700, Catalyst 2100,
and Catalyst 2800.
CURRENT DOCUMENTATION AVAILABLE
* CiscoView 3.1.(1) Release Note
* CiscoWorks Windows 2.0(1) Release Note
* CiscoView CD Installation Instructions
* CiscoWorks Windows CD Installation Instructions
* CiscoWorks Windows Getting Started Guide
* Downloading New Cisco Devices and Applications (quick reference card)
CAVEATS
In the front panel display of the Cat 2800 and CPW 1400, the
Connect and Disabled LEDs on FDDI modules do not reflect the appropriate
status.
CPW 1400, Cat 2800-Do not attempt to invoke the Monitoring menu for an FDDI
port or a repeater port. There is no monitoring function provided for these
ports, although the pull-down menu is enabled when such ports are selected.
CPW 1400, Cat 2800-The Configure Module Windows do not work when more than
one module type is selected. Select only one module type before opening
these windows.
CPW 1200, CPW 1400, Cat 2100, Cat 2800-The General Bridge window shows the
bridge information for VLAN1 only. Bridge information for other VLANs is
not available.
CPW 1200, CPW 1400, Cat 2100, Cat 2800-The Spanning Tree Protocol Window
for switched ports is available for ports in VLAN1 only. This window does
not show valid information for ports not in VLAN1.
The CPW10-100 do not show version information in the About CiscoView
dialog box. In these cases, the CiscoView About dialog box displays the package version only. However, the version information is displayed
in the "Packages Installed" list.
Changes from CiscoPro 2200.cv311.1-1:
- Minor modification to the CISCO-STACK-MIB; no functional change.
This ReadMe file describes the CiscoPro 2200 device
package, and associated:
* network management platforms
* operating systems
* current documentation available
* caveats, if any
NETWORK MANAGEMENT PLATFORMS
The network management platforms are the same platforms available for
CiscoView 3.1(1) and CiscoWorks Windows 2.0(1):
* On a Sun workstation: SunNet Manager, 2.2.2
* On a Sun workstation: Hewlett-Packard (HP) OpenView, 3.3
* On an HP system: HP OpenView, 3.3
* On an AIX system: NetView for AIX 3.1 or 4.1
* On a PC: HP OpenView for Windows, 7.2b (C.02.14 or 2.14)
* On a PC: CastleRock SNMPc, 4.1g with HP OpenView emulation support
OPERATING SYSTEMS
The CiscoPro 2200 device package currently runs on the
same operating systems as CiscoView 3.1(1) and CiscoWorks Windows 2.0(1):
* Sun running Solaris 1.x (SunOS 4.1.3, SunOS 4.1.3_U1, or SunOS 4.1.4),
or Solaris 2.4 with recommended patches as of 3/16/95
* HP running HP-UX A.09.03/A.09.04./A.09.05
* AIX, 3.2.5 or 4.1
* Windows 95, 4.0
* Windows NT, 3.51
CISCO SOFTWARE RELEASES
Cisco software releases 2.1 for the CiscoPro 2200.
NEW FEATURES
This device package extends the CiscoView device manager to include support for:
* CDP (Cisco Discovery Protocol) configuration
* VTP (VLAN Trunk Prootocol) configuration
* CiscoView launch of Traffic Director for RMON capable switches
* WS-X5020: 48 port 10BaseT Group Switching Ethernet Module
* WS-X5011: 12 port 10Base FL module
* WS-X5213: 12 port 10/100 Base TX module
CURRENT DOCUMENTATION AVAILABLE
* CiscoView 3.1.(1) Release Note
* CiscoWorks Windows 2.0(1) Release Note
* CiscoView CD Installation Instructions
* CiscoWorks Windows CD Installation Instructions
* CiscoWorks Windows Getting Started Guide
* Downloading New Cisco Devices and Applications (quick reference card)
CAVEATS
Please refer to the "Release notes for CWSI UNIX Version 1.0", Document
Number 78-3337; for additional information about CiscoView 3.1 and Traffic
Director.
If CiscoView 3.1.1 is installed on an HP OpenView platform, the CiscoView
application will query and use the device's community name settings from
HPOV, whether CiscoView is launched from the command line or from the
HPOV main menu. When this is done through HPOV, any further standalone
invocation of CiscoView will take the community string from HPOV until
the nmcview script exports the platform.
The IP Route device configuration window is not scrollable. Use the
numbered arrow keys to scroll the window.
Under a heavy load condition, CiscoPro 2200 SNMP responses are slow.
You may see an "error, no response since...." message in the
CiscoView status window. Select Options>Properties and increase
the Polling Frequency and Timeout values. [CSCdi57962]
Do not use the Grapher in the CiscoView Monitor "10BaseT Group Switching
Ethernet" window. Use the Monitor or Traffic Director tools to see
graphical views of the selected repeater ports.
The embedded RMON agent in the CiscoPro 2200 only supports the Ethernet
Statistics and Ethernet History Groups. Data Capture and Host List do
not work on the CiscoPro 2200.
For the CiscoPro 2200, if the number of the embedded RMON agent is
over 50,you cannot create any new embedded RMON agent group for
the new port. Use the Domain Manager to deinstall the agent group
from the unused port to free the memory resource.
When you select the repeater module port on a CiscoPro 2200, it always
uses the first port of the selected segment to create the RMON agent
group. If you see "IP address is not set in sysIpAddr Mib variable,"
it is because the Catalyst 1200 SNMP agent does not store the correct
IP address in the sysIpAddr MIB variable, so you have to use CiscoView
to correct it. Go to Configure>Device, enter the correct IP address
in the corresponding field, and click Modify.
This readme file describes the Cisco Catalyst WG-Concentrator
device package with support for the following new features:
* WS-X1431: 4 port Multi Mode FDDI (MIC connector)
* WS-X1450: 2 port MM FDDI (MIC), 12 port CDDI (RJ-45)
NETWORK MANAGEMENT PLATFORMS
The network management platforms are the same platforms available for
CiscoView 3.1(1) and CiscoWorks Windows 2.0(1):
* On a Sun workstation: SunNet Manager, 2.2.2
* On a Sun workstation: Hewlett-Packard (HP) OpenView, 3.3
* On an HP system: HP OpenView, 3.3
* On an AIX system: NetView, 3.2.1, 4.1
* On a PC: HP OpenView for Windows, 7.2b (C.02.14 or 2.14)
* On a PC: CastleRock SNMPc, 4.1g with HP OpenView emulation support
OPERATING SYSTEMS
The Cisco Catalyst WG-Concentrator device package currently runs on the
same operating systems as CiscoView 3.1(1) and CiscoWorks Windows 2.0(1):
* Sun running Solaris 1.x (SunOS 4.1.3, SunOS 4.1.3_U1, or SunOS 4.1.4),
or Solaris 2.4 with recommended patches as of 3/16/95
* HP running HP-UX A.09.03/A.09.04./A.09.05
* AIX, 3.2.5 and 4.1
* Windows 95, 4.0
* Windows NT, 3.51
MIB FILES
Check Cisco Connection Online at the following URL for published
MIBs for this product: ftp://ftp-eng.cisco.com/pub/mibs/supportlists
TAR FILES
The following .tar file contains the ".pkg" file for the
WG_Concentrator : WG_Concentrator.cv311.1-2.tar
DEVICES SUPPORTED
* Cat1000
* Cat1100
* Cat1400
CURRENT DOCUMENTATION AVAILABLE
* CiscoView 3.1.(1) Release Note
* CiscoWorks Windows 2.0(1) Release Note
* CiscoView CD Installation Instructions
* CiscoWorks Windows CD Installation Instructions
* CiscoWorks Windows Getting Started Guide
* Downloading New Cisco Devices and Applications (quick reference card)
CAVEATS
If CiscoView 3.1.1 is installed on an HP OpenView platform, theCiscoView
application will query and use the device's community name settings from
HPOV, whether CiscoView is launched from the command line or from the
HPOV main menu. When this is done through HPOV, any further standalone
invocation of CiscoView will take the community string from HPOV until
the nmcview script exports the platform.
The document discusses the LS1010 device and information about its use with
specific network management platforms and operating systems, Cisco IOS
Software Releases, applets supported, and any caveats that may exist.
NETWORK MANAGEMENT PLATFORMS
The LS1010 device package will run under the following Network Management
platforms:
Sun OS : SunNet Manager 2.2.2, HPOV 3.3
Solaris : SunNet Manager 2.2.2, HPOV 3.3
HPUX : HPOV 3.3
Win 95/NT : CastleRock SNMPc
Cisco IOS Software Releases
Cisco Software Release 11.1, IISP release for LS1010.
CURRENT DOCUMENTATION AVAILABLE
* CiscoView 3.1.(1) Release Note
* CiscoWorks Windows 2.0(1) Release Note
* CiscoView CD Installation Instructions
* CiscoWorks Windows CD Installation Instructions
* CiscoWorks Windows Getting Started Guide
* Downloading New Cisco Devices and Applications (quick reference card)
Caveats
OAM ping functionality is grayed out since this is not available
yet in the 11.1, IISP release for LS1010.
NETWORK MANAGEMENT PLATFORMS
The network management platforms are the same platforms available for
CiscoView 3.1(1) and CiscoWorks Windows 2.0(1):
* On a Sun workstation: SunNet Manager, 2.2.3
* On a Sun workstation: Hewlett-Packard (HP) OpenView, 3.3
* On an HP system: HP OpenView, 3.3
* On an AIX system: NetView, 3.2.1, 4.1
* On a PC: HP OpenView for Windows, 7.2b (C.02.14 or 2.14)
* On a PC: CastleRock SNMPc, 4.1g with HP OpenView emulation support
OPERATING SYSTEMS
These device packages currently runs on the
same operating systems as CiscoView 3.1(1) and CiscoWorks Windows 2.0(1):
* Sun running Solaris 1.x (SunOS 4.1.3, SunOS 4.1.3_U1, or SunOS 4.1.4),
or Solaris 2.4 with recommended patches as of 3/16/95
* HP running HP-UX A.09.03/A.09.04./A.09.05
* AIX, 3.2.5 and 4.1
* Windows 95, 4.0
* Windows NT, 3.51
CISCO SOFTWARE RELEASES
The following firmware versions are required:
Fasthub 100+ v. 1.12 or higher
MIB FILES
Check Cisco Connection Online at the following URL for published
MIBs for this product: ftp://ftp-eng.cisco.com/pub/mibs/supportlists
TAR FILES
The following .tar file contains the ".pkg" file for the
Fasthub 100+: FHUB_100+.cv311.1-0.tar
DEVICES SUPPORTED
* Fasthub 100+
NETWORK PROCESSOR MODULES SUPPORTED
* ws-x116
* ws-c116-nmm
CURRENT DOCUMENTATION
* CiscoView 3.1.(1) Release Note
* CiscoWorks Windows 2.0(1) Release Note
* CiscoView CD Installation Instructions
* CiscoWorks Windows CD Installation Instructions
* CiscoWorks Windows Getting Started Guide
* Downloading New Cisco Devices and Applications (quick reference card)
CAVEATS
Since Sun NetManager does not install the RMON MIB by default, RMON
TRAPs received by SNM are not listed. To avoid this problem please
manually load the RMON MIB in Sun NetManager. CSCdi77418
Sun NetManager does not correctly interpret the Logon Intrusion TRAP.
SNM lists it as a Reload TRAP. To avoid this problem, edit the
snmp.traps file manually and move the Reload Trap definition to the
bottom of the file. CSCdi77421
For device that have an expansion module, the port numbering is
not consistent with the management console. Ports 17 thru 32 are
listed in CiscoView as Repeater 2: Port 1 thru 16. CSCdi77159
After the first reset of the Fasthub 100+, the user must set the
'rptrReset' MIB variable to 'noReset' (default value) before
the next reset can be performed. This is due to a problem on
the Fasthub 100+ device software and will be fixed in a later
release. CSCdi77452
NETWORK MANAGEMENT PLATFORMS
The network management platforms are the same platforms available for
CiscoView 3.1(1) and CiscoWorks Windows 2.0(1):
* On a Sun workstation: SunNet Manager, 2.2.3
* On a Sun workstation: Hewlett-Packard (HP) OpenView, 3.3
* On an HP system: HP OpenView, 3.3
* On an AIX system: NetView, 3.2.1, 4.1
* On a PC: HP OpenView for Windows, 7.2b (C.02.14 or 2.14)
* On a PC: CastleRock SNMPc, 4.1g with HP OpenView emulation support
OPERATING SYSTEMS
These device packages currently runs on the
same operating systems as CiscoView 3.1(1) and CiscoWorks Windows 2.0(1):
* Sun running Solaris 1.x (SunOS 4.1.3, SunOS 4.1.3_U1, or SunOS 4.1.4),
or Solaris 2.4 with recommended patches as of 3/16/95
* HP running HP-UX A.09.03/A.09.04./A.09.05
* AIX, 3.2.5 and 4.1
* Windows 95, 4.0
* Windows NT, 3.51
CISCO SOFTWARE RELEASES
The following firmware versions are required:
Netbeyond Fasthub 300 v. 1.12 or higher
MIB FILES
Check Cisco Connection Online at the following URL for published
MIBs for this product: ftp://ftp-eng.cisco.com/pub/mibs/supportlists
TAR FILES
The following .tar file contains the ".pkg" file for the Netbeyond
Fasthub 300: NETBEYOND_FHUB_300.cv311.1-0.tar
DEVICES SUPPORTED
* Netbeyond Fasthub 300
NETWORK PROCESSOR MODULES SUPPORTED
* cpw3116-x
* cpw300-nmm
CURRENT DOCUMENTATION
* CiscoView 3.1.(1) Release Note
* CiscoWorks Windows 2.0(1) Release Note
* CiscoView CD Installation Instructions
* CiscoWorks Windows CD Installation Instructions
* CiscoWorks Windows Getting Started Guide
* Downloading New Cisco Devices and Applications (quick reference card)
CAVEATS
Since Sun NetManager does not install the RMON MIB by default, RMON
TRAPs received by SNM are not listed. To avoid this problem please
manually load the RMON MIB in Sun NetManager. CSCdi77418
Sun NetManager does not correctly interpret the Logon Intrusion TRAP.
SNM lists it as a Reload TRAP. To avoid this problem, edit the
snmp.traps file manually and move the Reload Trap definition to the
bottom of the file. CSCdi77421
For device that have an expansion module, the port numbering is
not consistent with the management console. Ports 17 thru 32 are
listed in CiscoView as Repeater 2: Port 1 thru 16. CSCdi77159
After the first reset of the Netbeyond Fasthub 300, the user must
set the 'rptrReset' MIB variable to 'noReset' (default value) before
the next reset can be performed. This is due to a problem on
the Netbeyond Fasthub 300 device software and will be fixed in a later
release. CSCdi77452
This README file includes the following sections:
* Introduction
* Network Management platform
* Operating systems
* Tar file or ZIP file
* Supported Devices
* Current documentation
* Caveats
INTRODUCTION
Threshold Manager is a CiscoView-launched threshold management application
that monitors the availability and performance of Cisco devices.
NETWORK MANAGEMENT PLATFORMS
The Cisco network management application used to launch Threshold Manager
is CiscoView 3.1(1.0).
OPERATING SYSTEMS
Sun running Solaris 1.x (SunOS 4.1.3, SunOS 4.1.3_U1, or SunOS 4.1.4), or
Solaris 2.4 with recommended patches as of 3/16/95
HP running HP-UX 09.05, HP-UX10.01
NetView for AIX3.2, AIX4.2
Windows 95 4.0
Windows NT 3.51
Notes: To execute Threshold Manager in standalone mode (not launched from
CiscoView):
1. On Windows NT,
if the NetPlus WinSNMP icon still shows after all
instances of Threshold Manager have been exited, you will also need to
exit NetPlus WinSNMP. This will ensure that the NetPlus SNMP stack is
in sync with Threshold Manager.
2. On SUNOS,
the user should set the environmental variables before executing
Threshold Manager from command line:
C Shell:
setenv XNLSPATH <Threshold Manager Directory>/nls
setenv XKEYSYMDB <Threshold Manager directory>/nls/XKeysymDB
Bourne/Korn shell:
export XNLSPATH = <Threshold Manager directory>/nls
export XKEYSYMDB = <Threshold Manager directory>/nls/XKeysymDB
3. On UNIX platforms,
The Hyperhelp needs the environment variable HHHOME to be set to
<CiscoView Directory>/hyperhelp. Also ensure that the environment
variable LD_LIBRARY_PATH is set.
TAR FILE
The TM-SOL.cv311.P1-1.tar file (Solaris), TM-SUNOS.cv311.P1-1.tar file,
TM-HPUX9.cv311.P1-1.tar file, TM-HPUX10.cv311.P1-1.tar file,
TM-AIX.cv311.P1-1.tar file and TM-NT95.cv311.P1-1.zip (WindowsNT 3.51 and
Windows95) file includes the electronic network management package file
(Threshold_<OS>.pkg).
The tar file also includes a copy of this README file in ASCII format, and
a copy of the Threshold Manager Getting Started Guide in pdf format.
DEVICES SUPPORTED
Threshold Manager supports Cisco IOS Releases 11.1 and 11.2 devices
that support RMON events and alarms. It also supports the Cat1200 and
Cat5000 switches. The Cat5000 switches support the Ethernet
statistics group only. The 1200 series supports the setting of Ethernet
statistics and all other MIB variables.
If the switching device packages have not been updated on the supported
Catalyst devices, you need to make the following changes in order to use
Threshold Manager:
Add the line:
source $Cv_Path/devices/All-share/CRMON.dd
to the end of each of the following files:
$Cv_Path/devices/Cat5000/C5000.dd
$Cv_Path/devices/Cat1200/C1200.dd
$Cv_Path/devices/Cat1200/C1200V4.dd
For Cisco7000 routers:
If the new 7000 package has not been updated and If you are unable to
see the Tools pulldown menu containing the Threshold Manager item,
the following two changes are needed in the c7com.dd file
(located in NMSROOT/etc/cview/devices/7000/dd/c7com.dd):
1) Change:
source $Cv_Path/devices/Router-share/CRTOOLBR.dd
source $Cv_Path/devices/Router-share/C47CH.dd
To:
source $Cv_Path/devices/Router-share/C47CH.dd
source $Cv_Path/devices/Router-share/CRTOOLBR.dd
2) Change:
set DD(menubar.menu) {{{} "Admin" admin}}
To:
lappend DD(menubar.menu) {{} "Admin" admin}
The various performance and fault indicators of Cisco devices can be monitored
by using the Threshold Manager application. This application takes advantage of
the RMON alarm and event groups implemented in the agent to set thresholds.
Since there are different levels of RMON support in terms of what variables may
be set among the agent implementations, a user of a generic RMON application
might have to try multiple times for each setting. Threshold Manager
application simplifies the user's task by learning of the agent capability and
limiting the setting to just these supported variables. In addition, for quick
setting of thresholds, Threshold Manager comes with a set of predefined
threshold policies that can be used as is or modified to suit a particular site.
Support for setting thresholds in Cisco devices varies in terms of which
variables can be set. First of all, thresholds can only be set on INTEGER,
Counter, Gauge, and Timeticks MIB variables. Some Cisco devices limit further
the set of MIB variables that can be used to set thresholds. Note that some
devices require the RMON feature to be enabled before you can set thresholds.
For example, IOS-based devices might have the RMON feature enabled or disabled.
Catalyst switches enable or disable the RMON function depending on the value
of the sysEnableRmon MIB object (in the CISCO-STACK-MIB).
IOS-Based Devices:
-----------------
All routers starting with the IOS version 11.1 have RMON threshold capability.
There are 2 implementations of RMON in the IOS-based agents. Both versions
support the setting of all MIB variables the agent supports (subject to the
above restriction on the MIB variable type). This includes, for example, MIB-II
variables and Cisco enterprise MIB variables.
The so-called RMON-lite implementation supports all the MIBs that the agent
supports. The full RMON implementation (with an 'm' in the image name) extends
over all RMON groups. For Threshold Manager users, this means the setting of
the Ethernet statistics group is also supported.
Threshold Manager Support for Default Thresholds
---------------------------------------------
To ease the setting of threshold variables, the Threshold Manager comes with
a set of predefined threshold policies. The predefined policies cover a wide
range of MIB variables that might prove useful for setting thresholds. These
variables are organized in several groups:
(1) System. These are system group variables that are part of the Cisco System
MIB. Examples are the CPU busy percentage and the available memory size.
(2) Interfaces. MIB-II interfaces and Cisco local interface variables are
predefined. Examples of this group are ifInOctets and locIfResets.
(3) Ethernet Statistics variable. Interesting MIB variables from this group,
such as etherStatsPkts and etherStatsCollisions, are included in the
predefined threshold policies.
In total, there are 18 predefined threshold policies. Support for these
predefined MIB variables also includes the run-time (at program startup
time) filtering of MIB variables that are not supported by a particular device.
Threshold Manager presents the user with relevant MIB variables for selection.
Note that many of these are interface-related MIB variables and so can be
applied to multiple MIB instances. This can be done automatically by Threshold
Manager. Pre-defined MIB variables may be changed and saved to disk for future
reference. The user has the option to save an altered policy to be used by all
devices, by all devices of the same class, or just for the current device.
Support for Customized Thresholds
---------------------------------
With the predefined set of threshold policies, a wide range of MIB variables
useful for monitoring is available for immediate use to the user. The user
can always modify the threshold values for these variables.
Beyond the predefined set of threshold policies, Threshold Manager provides
limited support for creating customized threshold policies or settings. This
task starts with the classification of a threshold variable. The classification
allows the user, for example, to specify the threshold to be applied to all
interfaces or even a particular subset based on the interface speed. Another
example is that the user can specify a threshold in terms of percentage of
bandwidth and Threshold Manager will automatically calculate the actual
threshold value when it creates the RMON entries. The interface could be MIB-II
interface or Cisco interface extension. This subdivision allows Threshold
Manager to present just the applicable MIB variables for a particular device.
Depending on the selection of the classification (target type), Threshold
Manager will enable or disable the appropriate input fields.
For specific MIB variables that are not part of an interface table (MIB-II or
Cisco specific), the user can fully qualify the threshold variable including
the instance Object ID. This customization feature practically allows for
the creation of any threshold. One limitation is that this kind of
customization cannot be saved to disk. Also note that, per RFC 1573, not all
objects in the interface MIB apply to all interface types. Make sure that a
given MIB object is applicable for that interface type by directly retrieving
it before you attempt to apply thresholds to it.
Note: the deletion of threshold polices is not supported by
Threshold Manager. This limitation includes both the predefined and
customized threshold policies. The user needs to go the disk directory of the
threshold configuration to delete unwanted threshold policies.
OTHER DEVICES
--------------
For RMON-supported devices that are not supported by CiscoView, Threshold
Manager must be started from the command line or by selecting File->New
from the Threshold Manager main menu. See Chapter 1 of the Threshold
Manager Getting Started Guide for more details.
CURRENT DOCUMENTATION
Look for the Threshold Manager Getting Started Guide on the Cisco Connection
Documentation, Enterprise Series CD-ROM. This manual is also included in
the tar and ZIP files in PDF format.
NOTES
* When you start Threshold Manager using the wrong write community string,
the application runs as read-only. All profiles are loaded at start time,
but they cannot be enforced.
* If a new default policy is enforced by one instance of Threshold Manager
and another instance is viewing events, the second instance will not be
able to view all information for the policy until user executes Retrieve
Threshold in the Config Thresholds dialog.
CAVEATS
This section contains caveats about problems you might encounter while using
Threshold Manager.
Some agents, most notably the Catalyst switches, impose a limit on the number
of alarm and event entries that can be created. Applying a large number of
thresholds to these devices will likely fail. In this case, some alarm entries
might be successfully created but their associated event entries are not.
These failed creations are marked as "Failed" in the Current Threshold
Settings pane. If you attempt to delete those settings, Threshold Manager
reports that the deletion failed (because it cannot delete nonexistent
event entries.) In this case, you can ignore the error message, and can
verify that the deletion occurred by retrieving the threshold settings after
the deletion.
#1.
ID #: CSCdi61080
Description:
Cisco7000 devices do not display Threshold Manager in the CiscoView
pulldown menu.
Workaround:
See the Supported Devices section above for information on how to
modify the c7com.dd file or update the 7000 package.
#2.
ID #: CSCdi62741
Description:
New policies are always added to the display list.
Workaround:
Exit from the Configure Thresholds window, then reopen it.
#3.
ID #: CSCdi62739
Description:
Policy file names won't match if IP address is used.
Workaround:
Use hostname instead of IP address when saving host-specific policies.
#4.
ID #: CSCdi68329
Description:
Duplicate global/device/host policies may be allowed, depending on which
window is used.
Workaround:
When creating a custom policy, you can only save it once, either as global,
device or host. But after saving the policy, you can use the Modify
Threshold Policy window to modify the saved custom policy and save it
as all three.
#5.
ID #: CSCdi69251
Description:
On Solaris, the Source field in the Config Threshold Policy window shows
HOST for profiles saved as host-specific, but NT displays the actual name
of the device.
Workaround:
None.
|