Table Of Contents
Network Management Vector Transport Alerts
Synchronous Data Link Control (SDLC)
Token Ring Media Access Control (MAC)— IEEE 802.5
Logical Link Control (LLC)—IEEE 802.2
Carrier Sense Multiple Access Collision Detect (CSMA/CD)
X.25 Packet Layer
Link Access Procedure-Balanced (LAP-B)
Qualified Logical Link Control (QLLC)
Transmission Control Protocol/Internet Protocol (TCP/IP)
TN3270
Network Management Vector Transport Alerts
The following tables describe the Network Management Vector Transport (NMVT) alerts generated by Cisco resources, categorized by protocol type:
• Synchronous Data Link Control (SDLC)
• Token Ring Media Access Control (MAC)— IEEE 802.5
• Logical Link Control (LLC)—IEEE 802.2
• Carrier Sense Multiple Access Collision Detect (CSMA/CD)
• X.25 Packet Layer
• Link Access Procedure-Balanced (LAP-B)
• Qualified Logical Link Control (QLLC)
• Transmission Control Protocol/Internet Protocol (TCP/IP)
• TN3270
The following information is used to describe the alerts:
•Alert ID—Number that identifies the alert
•Failure cause—Two-byte hexadecimal code
•Alert description—Brief description of the alert
Note Alert descriptions that are displayed in parentheses ( ) indicate the Communications Manager (CM) description. Alert IDs that are displayed in parentheses indicate the CM version of the alert ID.
Synchronous Data Link Control (SDLC)
Table D-1 SDLC Alerts
Alert ID
|
Failure Cause
|
Alert Description
|
32A37F1B
|
F017
|
Poll retry exhausted
|
BD84C4C9
|
F01A
|
DM received
|
D635CA1E
|
F015
|
SNRM received while in NRM
|
B776CA94
|
F010
|
FRMR received—invalid command/response
|
B3B7D723
|
F011
|
FRMR received—I-field not allowed
|
BEF4F1FA
|
F012
|
FRMR received—invalid Nr
|
BA35EC4D
|
F013
|
FRMR received—max I-field exceeded
|
15C2CCE5
|
F020
|
Protocol error by remote—invalid command/response
|
1103D152
|
F021
|
Protocol error by remote—I-field not allowed
|
1C40F78B
|
F022
|
Protocol error by remote—invalid Nr
|
EABB6A14
|
F01B
|
Protocol error by remote—MAXIN exceeded
|
0E2DDF11
|
F019
|
Inactivity timer expired (not being polled)
|
0AECC2A6
|
F018
|
XID retry exhausted
|
A472BC48
|
F014
|
FRMR received—no reason given
|
Token Ring Media Access Control (MAC)— IEEE 802.5
Table D-2 Token Ring MAC Alerts
Alert ID
|
Failure Cause
|
Alert Description
|
55BF3E1C
|
3434
|
Open failure—Lobe fault
|
CAF3C58A
|
3703
|
Open failure—TR Fault Domain (Beaconing)
|
D615A61E
|
Install Cause 3704
|
Open failure—Duplicate Token Ring address
|
44D1AD86
|
User Cause 7101
|
Open failure—Removed from Token Ring
|
016E5F4E
|
N/A
|
Adapter Open failed
|
A676B230
|
3434
|
Wire fault—Lobe fault
|
EB61E14F
|
N/A
|
Auto-removal (adapter removed itself from ring)
|
59F32622
|
User Cause 7101
|
Remove cmd rcvd—Removed from Token Ring
|
Logical Link Control (LLC)—IEEE 802.2
Table D-3 LLC Alerts
Alert ID
|
Failure Cause
|
Alert Description
|
5B8F5BA7
|
F017
|
Poll retry exhausted
|
B1D9A4C5
|
F01A
|
DM received
|
E65B0B7F
|
F016
|
SABME received while in ABME
|
8A5B2D2C
|
F010
|
FRMR received—invalid cmd/rsp
|
8E9A309B
|
F011
|
FRMR received—I-field not allowed
|
83D91642
|
F012
|
FRMR received—invalid Nr
|
87180BF5
|
F013
|
FRMR received—max I-field exceeded
|
23EF2B5D
|
F020
|
Protocol error by remote (FRMR sent)—invalid cmd/rsp
|
2C2E36EA
|
F021
|
Protocol error by remote (FRMR sent)—I-field not allowed
|
216D1033
|
F022
|
Protocol error by remote (FRMR sent)—invalid Nr
|
25AC0D84
|
F023
|
Protocol error by remote (FRMR sent)—max I-field exceeded
|
Carrier Sense Multiple Access Collision Detect (CSMA/CD)
Table D-4 CSMA/CD Alerts
Alert ID
|
Alert Description
|
8B1836C5
|
Open failure
|
EB1D6ABB
|
Remove cmd rcvd; User Cause 7107—removed from CSMA/CD ring
|
668E036D
|
Lost carrier
|
A48865FD
|
Congestion
|
91FDE97B
|
Bus inoperative failure
|
X.25 Packet Layer
Table D-5 X.25 Packet Layer Alerts
Alert ID
|
Failure Cause
|
Alert Description
|
B5B412E5 (D484ED27)
|
20C1
|
(DTE) Cleanup Indication Received (Clear/Reset)
|
CDA515B8
|
20C1
|
(DTE) Cleanup Indication Received (Restart)
|
D3A1B295 (6A837F72)
|
20C2
|
(DTE) Cleanup Request Sent (Reset)
|
056A9521
|
20C2
|
(DTE) Cleanup Request Sent (Clear/Restart)
|
F50A02F0
|
20D1
|
(DTE) Response timer expired
|
BA5D4659
|
20B2
|
(DTE) Protocol violation by remote
|
4C323FE5
|
20C3
|
Diagnostic Packet Received from Network
|
EFF5FAAD
|
20C4
|
(DCE) Cleanup Indication Sent (Restart/Reset/Clear)
|
FEC0F827
|
20C5
|
(DCE) Cleanup Request Received (Restart/Reset/Clear)
|
Link Access Procedure-Balanced (LAP-B)
Table D-6 LAP-B Alerts
Alert ID
|
Failure Cause
|
Alert Description
|
07B1E788
|
F023
|
Protocol error by remote (FRMR sent)—max I-field exceeded
|
C0E4E919
|
F022
|
Protocol error by remote (FRMR sent)—invalid Nr
|
A596712C (CEA222A9)
|
N/A
|
LAP-B Comms error (Poll retry exhausted)
|
985806E2
|
N/A
|
LAP-B Comms error (Unexpected DISC received)
|
00891F75
|
F010
|
FRMR received—invalid cmd/rsp
|
CF6F806D
|
F011
|
FRMR received—I-field not allowed
|
F5E40347
|
F013
|
FRMR received—max I-field exceeded
|
C22CA6B4
|
F012
|
FRMR received—invalid Nr
|
1F9CF04A
|
F020
|
Protocol error by remote (FRMR sent)—invalid cmd/rsp
|
3FAE0180
|
F021
|
Protocol error by remote (FRMR sent)—I-field not allowed
|
Qualified Logical Link Control (QLLC)
Table D-7 QLLC Alerts
Alert ID
|
Failure Cause
|
Alert Description
|
6460D9A9
|
F023
|
—
|
3DA4F8CD
|
F010
|
QFRMR received—invalid cmd/rsp
|
C15B15E8 (9C064C98)
|
F011
|
QFRMR received—I-field not allowed
|
C8C9E4FF (D82E7FD3)
|
F013
|
QFRMR received—max I-field exceeded
|
11A865CF (21F2236D)
|
F020
|
Protocol error by remote (QFRMR sent)—invalid cmd/rsp
|
0283E638 (5DBB5F97)
|
F021
|
Protocol error by remote (QFRMR sent)—I-field not allowed
|
Transmission Control Protocol/Internet Protocol (TCP/IP)
Table D-8 TCP/IP Alerts
Alert ID
|
Failure Cause
|
Alert Description
|
E14A3440
|
3200, 2081
|
TCP/IP alert link lost alert
|
0C16CC4C
|
3200, 2058
|
HDLC keep alive failed
|
3F1DE404
|
3601, 3401, f038
|
HDLC alert signal lost
|
EDFE42AA
|
2055, 2060
|
CIP LLC connection limit exceeded
|
13797053
|
3003, 2007, 1023
|
CIP LLC duplicate SAP detected
|
TN3270
Table D-9 TN3270 Alerts
Alert ID
|
Failure Cause
|
Alert Description
|
9E452D9C
|
22a1
|
TN3270 server APPN-DLUR protocol error
|
1DA682C3
|
22a1
|
TN3270 server APPN-DLUR configuration error
|
05CB2789
|
22a1
|
TN3270 server APPN-DLUR configuration error
|
017153F1
|
22a1
|
SNA session setup failure
|
85FDA5F1
|
22a1
|
SNA protocol error
|
D9039DB7
|
22a1
|
TN3270 server capacity exceeded
|
A10EE2D6
|
22a1
|
TN3270 server no memory for operation
|