Alert descriptions that are displayed in braces {} indicate the Communications Manager (CM) description. Alert IDs that are displayed in braces indicate the CM version of the alert ID.
Alert ID
| Failure Cause
| Alert Description
|
---|
32A37F1B
| F017
| Poll retry exhausted
|
BD84C4C9
| F01A
| DM received
|
D635CA1E
| F015
| SNRM received while in NRM
|
B776CA94
| F010
| FRMR received--invalid command/response
|
B3B7D723
| F011
| FRMR received--I-field not allowed
|
BEF4F1FA
| F012
| FRMR received--invalid Nr
|
BA35EC4D
| F013
| FRMR received--max I-field exceeded
|
15C2CCE5
| F020
| Protocol error by remote--invalid command/response
|
1103D152
| F021
| Protocol error by remote--I-field not allowed
|
1C40F78B
| F022
| Protocol error by remote--invalid Nr
|
EABB6A14
| F01B
| Protocol error by remote--MAXIN exceeded
|
0E2DDF11
| F019
| Inactivity timer expired (not being polled)
|
0AECC2A6
| F018
| XID retry exhausted
|
A472BC48
| F014
| FRMR received--no reason given
|
Table D-3: LLC IEEE 802.2 Alerts
Alert ID
| Failure Cause
| Alert Description
|
---|
5B8F5BA7
| F017
| Poll retry exhausted
|
B1D9A4C5
| F01A
| DM received
|
E65B0B7F
| F016
| SABME received while in ABME
|
8A5B2D2C
| F010
| FRMR received--invalid cmd/rsp
|
8E9A309B
| F011
| FRMR received--I-field not allowed
|
83D91642
| F012
| FRMR received--invalid Nr
|
87180BF5
| F013
| FRMR received--max I-field exceeded
|
23EF2B5D
| F020
| Protocol error by remote (FRMR sent)--invalid cmd/rsp
|
2C2E36EA
| F021
| Protocol error by remote (FRMR sent)--I-field not allowed
|
216D1033
| F022
| Protocol error by remote (FRMR sent)--invalid Nr
|
25AC0D84
| F023
| Protocol error by remote (FRMR sent)--max I-field exceeded
|
Table D-5: X.25 Packet Layer Alerts
Alert ID
| Failure Cause
| Alert Description
|
---|
B5B412E5 {D484ED27}
| 20C1
| (DTE) Cleanup Indication Received {Clear/Reset}
|
CDA515B8
| 20C1
| (DTE) Cleanup Indication Received {Restart}
|
D3A1B295 {6A837F72}
| 20C2
| (DTE) Cleanup Request Sent {Reset}
|
056A9521
| 20C2
| (DTE) Cleanup Request Sent {Clear/Restart}
|
F50A02F0
| 20D1
| (DTE) Response timer expired
|
BA5D4659
| 20B2
| (DTE) Protocol violation by remote
|
4C323FE5
| 20C3
| Diagnostic Packet Received from Network
|
EFF5FAAD
| 20C4
| (DCE) Cleanup Indication Sent {Restart/Reset/Clear}
|
FEC0F827
| 20C5
| (DCE) Cleanup Request Received {Restart/Reset/Clear}
|
Table D-6: LAP-B Alerts
Alert ID
| Failure Cause
| Alert Description
|
---|
07B1E788
| F023
| Protocol error by remote (FRMR sent)--max I-field exceeded
|
C0E4E919
| F022
| Protocol error by remote (FRMR sent)--invalid Nr
|
A596712C {CEA222A9}
|
| LAP-B Comms error {Poll retry exhausted}
|
985806E2
|
| LAP-B Comms error {Unexpected DISC received}
|
00891F75
| F010
| FRMR received--invalid cmd/rsp
|
CF6F806D
| F011
| FRMR received--I-field not allowed
|
F5E40347
| F013
| FRMR received--max I-field exceeded
|
C22CA6B4
| F012
| FRMR received--invalid Nr
|
1F9CF04A
| F020
| Protocol error by remote (FRMR sent)--invalid cmd/rsp
|
3FAE0180
| F021
| Protocol error by remote (FRMR sent)--I-field not allowed
|