This appendix describes how to configure CNOM. It contains several sections:
To configure a CNOM system, you must complete the following:
After installation, configure CNOM using script utilities supplied with the product to create mapping objects and set the various attributes in CEMF that CNOM uses during connection management. Examples of configuration tasks that are carried out are:
Configuration is normally required after any new device is installed in the network if the new device is to support connections managed by CNOM.
Network orders that create connections contain the attribute serviceCharacteristics
, whose value corresponds to the names of profiles that will be applied by the various participating element managers. The settings in each profile should support the intended characteristics of the connection. So, an ADSL profile called Gold in CDM sets line speeds on a DSL port which match the speed settings in the Gold SCM connection template that is applied to a PVC cross-connect.
Each element manager must be configured to contain profiles corresponding to each possible value of serviceCharacteristics
. For example, suppose you have the following transport speeds and DSL types:
In this case you might set up DMT, ADSL, CAP and ATM QoS profiles named ADSL-1.5x384
and ADSL-512x128
, and SDSL and ATM QoS profiles named SDSL-512
and SDSL-256
. In the network order, you would also specify the name of the appropriate profile for the serviceCharacteristics
attribute.
The primitive ConfigureDSLPort, used in the policy connectSubscriber
applies the profiles of the appropriate type for the port being configured.
The subtend hierarchy in CDM Release 3.0 is modeled in CEMF as a containment view called Subtend. All DSLAMs which are to be used by CNOM must appear in this view, even if they operate as standalone units. The view contains the chassis object for each DSLAM, and each chassis object contains its trunk and subtend ports. Chassis objects appear at either:
The policy setupSubtend
automatically sets up the DSLAM in a Subtend view and also sets the attributes to designate the network port and subtend ports.
To set up subtending, invoke the subtend command as follows:
./subtend node_chassis_path [subtend_port_path]
The subtend command includes two parameters:
Note When you upgrade from CNOM Release 1.03 or 1.05 or CDM Release 3.1 or later, you must remove the Subtend package before you begin the upgrade. |
To position a node under a subtend path:
1. The subtend port must already exist in the Subtend view. If the second parameter is not provided, the node is placed in the top level of the subtend view. For example, to set up a subtend view of three nodes (Node1/Node2/Node3), each with a single SONET trunk port and single SONET subtend port, run the following commands:
./subtend Physical:/Site-1/Node1-Shelf/Node1-Chassis
./subtend Physical:/Site-1/Node2-Shelf/Node2-Chassis subtend:/Node1-Chassis/SONET-10-2
./subtend Physical:/Site-1/Node3-Shelf/Node3-Chassis subtend:/Node2-Chassis/SONET-10-2
Physical:/.../C6100v30TrapMgmt/C6100v30ManagedElement/C6100v30MultiplexerChassis-1
Note Run the subtend command from the CEMF shell. |
2. After you set the information to the connected DSLAMs, tag each service instance with a service name to tell the service to which it is being connected. This name is used in the work order to identify the candidate set of service instances from which you choose the destination. Set the value using the socketDaSet command as follows:
./socketDaSet
<serviceInstance> LocalDB:C6400NOA.
serviceName (
<val>)
3. Replace <serviceInstance> with the full name of the service instance being used, and replace <val> with the desired name. For example:
socketDaSet Cisco6400ServiceView:/sw1/sw1-chassis/PPP-IP_Service-1 \
LocalDB:C6400NOA.serviceName "(AOL)"
For example:
For performance, line IDs are managed in an invisible view, ObjectMapView, under the technology object DDMTopology.lineID
. For each line ID assigned to a port, the system creates a map object whose name matches the line ID. The line ID object includes the following attributes:
LocalDB:DDMMappingObject.targetObject
The line port which is assigned this line ID.LocalDB:DDMMappingObject.subdomainId
The subdomain (the set of CNOM devices) that the line port belongs to: DSLAM or C6400DMM. In addition, the line port sets the value in its local attribute (LocalDB:DDMTopology.lineID
).
When you assign the value DSLAM-1,DSLAM-2,DSLAM-3 to a line port, the resulting configuration in CEMF is as follows:
ObjectMapView:/DDMTopology
with the names DSLAM-1, DSLAM-2, and DSLAM-3targetObject
is set as the ingress portLocalDB:DDMTopology.lineID
is assigned the line ID value DSLAM-1,DSLAM-2,DSLAM-3Line IDs are configured using policies which provide a more abstract form of mapping objects to arbitrary attribute values. The policies include:
./setMappingValues
Sets a new set of mapping values for the object./resetMappingValues
Resets existing mapping values for an object./addMappingValue
Adds a new mapping value to the object./removeMappingValue
Removes a mapping value from the object./findMappingTarget
Identifies an object with a mapping value and returns the target objectThe following command line scripts provide perl wrapper scripts to execute this policy:
./set_map_values
./reset_map_values
./add_map_value
./remove_map_value
./get_object_for_value
Command line scripts are provided to configure line IDs for CNOM.
Note If the same line IDs are assigned to more than one port, policies fail. |
Use the ./set_line_ids
script to assign a line ID to a DSLAM port to identify a subscriber line attached to the port. The script assigns a new ID to the port if none exists, or it overwrites an existing line ID with a new value. The command syntax is as follows:
./set_line_ids <
port> <
line_ID> DSLAM
Where:
<
port>
is the containment path of the ingress or egress port whose line ID you are setting. <
line_ID>
is a unique identifier for the subscriber, such as a circuit ID or telephone number. DSLAM
indicates that the line ID is assigned to a port in the DSLAM subdomain. The following command assigns the line ID 408-555-1212
to the DSLAM port Chelmsford/.../DMT-5-1
(where \
indicates that the command continues on a new line):
./set_line_ids ComponentManaged:/Chelmsford/ni2-90-shelf/ni2-90-chassis/D5/DMT-5-1 \ 4085551212 DSLAM
To identify the set of DSLAMs served by the UAC, set the line ID for a Cisco 6400 UAC port. The command syntax is as follows:
./set_line_ids <
port> <
line_ID> C6400DMM
For <
port>
, specify the containment path of the ingress or egress port whose line ID you are setting.
For <
line_ID>
, specify the set of DSLAMs served by the port (include commas between each DSLAM name). C6400DMM
indicates that the line ID is assigned to a port in the Cisco 6400 UAC subdomain.
The following command sets the line ID for the UAC port sw1-shelf/.../ATM-3-1-0
(where \
indicates that the command continues on a new line). The line ID indicates that the port serves DSLAM-1, DSLAM-2, and DSLAM-3.
./set_line_ids Cisco6400ServiceView:/sw1-shelf/sw1-chassis/sw1-nsp/OC3-3-1/ATM-3-1-0 \ DSLAM-1,DSLAM-2,DSLAM-3 C6400DMM
Note Run all of the following commands from the CEMF shell. |
./get_line_id <
port>
script prints the line ID of the ingress port for the specified port. For example, for the port sw1-shelf/.../ATM-3-1-0
, the script returns the value DSLAM-1,DSLAM-2,DSLAM-3
. ./get_object_for_line
script takes a line ID value and prints the containment path of the object that is assigned this value. For example, ./get_object_for_line DSLAM-1
returns the value:workOrder:DDMWorkOrder.objectName
Cisco6400ServiceView:/sw1-shelf/sw1-chassis/sw1-nsp/OC3-3-1/ATM-3-1-0
reset_line_ids
script resets the line ID for a specified port. For example, to reset the line ID for the port sw1-shelf/.../ATM-3-1-0
, issue the command as follows: ./reset_line_ids Cisco6400ServiceView:/sw1-shelf/sw1-chassis/sw1-nsp/OC3-3-1/ATM-3-1-0
./get_line_id
, the script returns an empty value (because the line ID has been reset). ./add_line_id
script assigns an additional line ID to the specified port's current line ID. For example, if the line ID is DSLAM-1,DSLAM-2,DSLAM-3 and you issue the following command, the line ID becomes DSLAM-1,DSLAM-2,DSLAM-3,DSLAM-4. ./add_line_id Cisco6400ServiceView:/sw1-shelf/sw1-chassis/sw1-nsp/OC3-3-1/ATM-3-1-0 \
DSLAM-4 C6400DMM
/remove_line_id
script removes a line ID from the port's current value. For example, the following command removes DSLAM-2, making the port's line ID value DSLAM-1,DSLAM-3,DSLAM-4:./remove_line_id Cisco6400ServiceView:/sw1-shelf/sw1-chassis/sw1-nsp/OC3-3-1/ATM-3-1-0
\ DSLAM-2 C6400DMM
./get_object_for_line DSLAM-2
, the script returns an error, as this value is no longer mapped to an object. Note Use the cleanup_line_Id command to remove line IDs that were not deleted before you removed a
chassis or uninstalled CNOM. For instance, if you attempt to use or remove a line ID from a removed
chassis and receive an error message that you can not use that particular line ID, run the
cleanup_line_Id [< LineId>] [< ContainmentPath>] command.
|
For CNOM to successfully make connections, you must name at least one fully configured quality of service (QoS) through the network. To set a quality of service, perform the following steps:
Step 1 Create a CDM Manager DMT profile using an appropriate name.
Step 2 Create a CDM Manager DSL profile using an appropriate name.
Step 3 Create a CDM Manager ATM connection profile using an appropriate name.
Step 4 Create an SCM connection template using an appropriate name.
Note An appropriate name in the above procedure is any convention that functions within the network administrator for keeping a variety of QoS packages uniquely identified. For example, Gold, Silver, and Bronze are identifiers that can designate (in a hierarchical order) various QoS packages. |
Tag each connection template with a profile name to tell CNOM which named QoS it represents. This name is used in the work order to identify the appropriate connection template for a connection.
Posted: Tue Sep 17 07:47:13 PDT 2002
All contents are Copyright © 1992--2002 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.