Table Of Contents
Cisco 12000/10720 v3.1.2 Router Manager
Install Cisco CNS / Cisco EMF Integration Patch
Quick Start Guide
Cisco 12000/10720 v3.1.2 Router Manager
The Cisco 12000/10720 Manager is an element management system (EMS) for configuration and troubleshooting core IP/MPLS networks based upon 12000 and 10720 routers. This EMS supports up to and including Cisco IOS 12.0(25)S as well as a wide range of line cards. Please consult the documentation for complete details.
This new release, version 3.1.2, includes management feature support for OSPF and BGP configuration, VRF configuration, MPLS troubleshooting capability and ATM Operations And Management (OAM) and includes all features of Cisco EMF v3.2 SP7. In particular, the CORBA™1 Gateway Developer toolkit - previously an optional purchase item for systems integrators - is now bundled for free. Cisco EMF v3.2 SP7 supports use of Resource Management Essentials (RME) v3.5 as well as RME v3.4.
CiscoWorks Common Services 2.2 contains cryptographic features and is subject to United States and local country laws governing import, export, transfer and use. Delivery of Cisco cryptographic products does not imply third-party authority to import, export, distribute or use encryption. Importers, exporters, distributors and users are responsible for compliance with U.S. and local country laws. By using this product you agree to comply with applicable laws and regulations. If you are unable to comply with U.S. and local laws, return this product immediately.
This document only provides a high-level overview of a new EMS installation, and startup, and is just one of the documents you should use. For comprehensive installation or upgrade procedures, refer to the Cisco 12000/10720 v3.1.2 Router Manager Release Notes, and the Cisco 12000/10720 v3.1.2 Router Manager Installation and Configuration Guide.
1 Take Out the CD-ROMs
•Cisco Element Management Framework Version 3.2 CD#1
•Cisco Element Management Framework Version 3.2 SP7 CD#2
•CiscoWorks Common Services 2.2 CD for Solaris and Resource Manager Essentials 3.5 for Solaris CD
or
CiscoWorks Common Services 2.2 CD for Windows and Resource Manager Essentials 3.5 for Windows CD•Cisco 12000/10720 Router Manager CD
2 Locate the Documents
The PDF documents are available on the Cisco EMF 3.2 SP7 CD#2 and the Cisco 12000/10720 Router Manager CD.
You can download the documents as follows:
•Cisco Element Management Framework Release Note Version 3.2 Service Pack 7 http://www.cisco.com/en/US/products/sw/netmgtsw/ps829/prod_release_notes_list.html
•Cisco 12000/10720 v3.1.2 Router Manager Release Note http://www.cisco.com/en/US/products/sw/netmgtsw/ps156/prod_release_notes_list.html
•Cisco 12000/10720 v3.1.2 Router Manager Installation and Configuration Guide http://www.cisco.com/en/US/products/sw/netmgtsw/ps156/products_installation_and_configuration_guide_books_list.html
•Cisco 12000/10720 v3.1.2 Router Manager User Guide http://www.cisco.com/en/US/products/sw/netmgtsw/ps156/products_user_guide_book_list.html
•Cisco Element Management Framework User Guide Version 3.2 Service Pack 7 http://www.cisco.com/en/US/products/sw/netmgtsw/ps829/products_user_guide_list.html
•Online help is available in your EMS.
Associated documents are available on Cisco.com
•Resource Manager Essentials from http://www.cisco.com/en/US/products/sw/cscowork/ps2073/ps5242/index.html
•CNS 2100 Series Intelligence Engine from http://www.cisco.com/en/US/products/sw/netmgtsw/ps4617/prod_technical_documentation.html
•CiscoWorks Common Services 2.2 http://www.cisco.com/en/US/products/sw/cscowork/ps3996/prod_technical_documentation.html
3 System Requirements
The Cisco-Sun hardware reference configurations for Cisco Element Managers are detailed in http://www.sun.com/oem/cisco/. Do not order hardware until you have referred to this.
4 Get a Cisco EMF License
Step 1 Go to the Software Registration page at:
http://cco.cisco.com/pcgi-bin/Software/FormManager/formgenerator.plStep 2 Click CEMF Product License.
Step 3 Enter your Contact Information.
Step 4 In the Version number field, choose 3.2.
Step 5 Enter the Product Authorization Key (PAK) number provided on the sleeve of the Cisco EMF product CD-ROM.
Step 6 Enter the hostname of the server where Cisco EMF will be installed.
Step 7 Enter the host ID (a hexadecimal string that identifies the system—not the IP address) of the server where Cisco EMF will be installed.
Note To get the host ID (at the Unix prompt) enter hostid
Step 8 Enter responses to the remaining questions.
Step 9 Click Submit.
To update a Cisco EMF license currently in use, (to extend an evaluation license, or convert an evaluation license to a permanent license), refer to the Cisco 12000/10720 v3.1.2 Router Manager Installation and Configuration Guide.
5 Install Cisco EMF Server
Use the following procedures when this is a new installation.
First install the server (consisting of the server processes and a local client) followed by the client (if necessary).
To install the Cisco EMF client, and for upgrade instructions, refer to the Installation and Configuration Guide.
Step 1 Log in as superuser (su) to the server where Cisco EMF is to be installed.
Step 2 Insert Cisco EMF CD#1 into the CD-ROM drive.
Step 3 Enter:
host# cd /cdrom/cdrom0
host# ./cemfinstallStep 4 Choose Server installation option.
Step 5 Enter a directory for the installation files (default is /opt/cemf). This directory is referred to as <CEMF_ROOT>.
Step 6 Enter a directory for backing up and restoring data (default is /opt/Backup).
Note For best performance, we recommend you install the databases on separate disks, and use RAWFS in certain circumstances. Refer to Cisco EMF Installation and Configuration Guide.
Step 7 Enter the server hostname and server IP address.
Step 8 Configure the ObjectStore option for your installation.
Step 9 Place the transaction log on a different drive from the installation and database files.
Note Do not store the transact.log file in /tmp as a reboot will remove any files in this area.
Step 10 Accept the default DNS domain for your server. Cisco EMF will work on a system without DNS.
Step 11 Enter the full path name of the
Cisco EMF license file.Step 12 When the installation is complete, cd out of the directory /cdrom/cdrom0 and enter eject.
6 Install Cisco EMF SP7
Note SP7 is shipped on Cisco EMF CD#2.
Step 1 Insert the Cisco EMF SP7 CD#2 into the CD-ROM drive.
Step 2 Enter:
host# cd /cdrom/cdrom0
host# ./cemfinstallStep 3 Choose installation option.
Step 4 cd out of the directory /cdrom/cdrom0 and enter eject.
7 Install the RME Server
Step 1 Decide if you want to run RME co-resident with your EMS or on a separate workstation (Sun or PC). RME cannot be co-resident with Cisco EMF on Solaris 2.6.
Step 2 Install CiscoWorks Common Services 2.2 CD, choose install option 4
Step 3 Install or upgrade RME. On Solaris, enter:
# cd /cdrom/cdrom0/
# ./setup.sh
Enter 3 and press Return.
On PC, insert the CD-ROM, the Installer window appears. Click Install. In the Wizard, select the Typical installation.
8 Install RME Add-on
The RME add-on is a separate software package which is installed on top of an existing CiscoWorks Common Services 2.2 and RME 3.5 installation.
Step 1 On Solaris, insert Cisco EMF CD#2 and change directory to the cdrom area. Enter cd rme/solaris, then enter ./install.
Step 2 On a PC where CiscoWorks and RME 3.5 are installed, insert Cisco EMF CD#2 and run the rme/windows/setup.exe file.
9 Install Cisco CNS / Cisco EMF Integration Patch
This patch must be installed on the CNS 2100 Series Intelligence Engine. Install CNS patch 1.2.3 first then the Cisco CNS/Cisco EMF Integration patch. The Cisco 2100 Series device must be set-up.
Step 1 Insert Cisco EMF CD#2. In cns/linux directory, list the packages installed on the CNS 2100 Series, enter rpm -qa | grep CSCO. If patch is detected, remove it, enter rpm -e CSCOcnsiepatch-1.0-1 (This is an example.)
Step 2 Copy Linux RPM package file. Note file name and location. From the directory, enter rpm -i CSCOcnsiepatch-1.0-1.i386.rpm (This is an example.) The file name must match the copied file. Restart the web server, enter /sbin/service httpd restart
10 Start Cisco EMF
Step 1 Log in to the server where Cisco EMF is installed.
Step 2 Change to the Cisco EMF bin directory:
cd <CEMF_ROOT>/bin where <CEMF_ROOT> is the directory where Cisco EMF is installed. Enter ./cemf start
11 Install the EMS
To install a Cisco 12000/10720 v3.1.2 Router Manager:
Step 1 Log in as superuser (su) to the server where Cisco EMF is installed.
Step 2 Insert Cisco 12000/10720 Router Manager product CD into the CD-ROM drive.
Step 3 Enter:
host# cd /cdrom/cdrom0
host# cd c12k-10720_3.1.2
host# ./c12kminstallStep 4 Choose the installation option.
12 Start a User Session
Step 1 Start a user session enter ./cemf session.
Step 2 Log in as an admin user and enter the admin (default login). The session starts and the Launchpad window is displayed.
1 CORBA (Common Object Request Broker Architecture) is a registered trademark of the Object Management Group.