cc/td/doc/product/rtrmgmt/baccable/cable27
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table Of Contents

Network Registrar Configuration File Example

Configuration Scripts

Sample Script for DOCSIS Modems and Computers

Sample Script for DOCSIS Modems and PacketCable MTAs


Network Registrar Configuration File Example


This appendix describes the sample configuration files included with this installation. This file is typical of the files you use during the BAC installation.

Configuration Scripts

This section describes sample configuration scripts that you can copy and use to work with your BAC implementation. One exists for DOCSIS modems and computers, while another is available for DOCSIS modems and PacketCable MTAs.

Sample Script for DOCSIS Modems and Computers

This sample configuration nrcmd script (bpr_cnr_hsd_sample_config.nrcmd) is used for a high-speed data deployment of DOCSIS modems and computers, in a multiple host configuration with failover protection. It is installed in this directory: <BACC_HOME>/cnr_ep/samples/.

These assumptions have been made to create this script:

DHCP primary server IP address is: 192.168.0.32

DNS primary server IP address is: 192.168.0.32

This sample script defines these objects:

Scope selection tag objects for provisioned client-classes.

Client-class objects for provisioned DOCSIS modems and computers.

Policy objects for unprovisioned and provisioned devices. The only difference is that DNS servers are not given to unprovisioned devices.

Scope and scope policy objects for unprovisioned and provisioned DOCSIS modems and computers.

Disable the TFTP server.

To run this script, in the Network Registrar nrcmd program, enter:

<NR_HOME>/usrbin/nrcmd -N <username> -P <password> -b < bpr_cnr_hsd_sample_config.nrcmd

Where:

-N—identifies the username

-P—identifies the password

Sample Script for DOCSIS Modems and PacketCable MTAs

This sample configuration nrcmd script (bpr_cnr_pktcbl_sample_config.nrcmd) is used for a high-speed data deployment of DOCSIS modems and PacketCable MTAs. A multiple host configuration with failover protection is also used, and the script is also installed in the <BACC_HOME>/cnr_ep/ samples/ directory.

These assumptions have been made to create this script:

DHCP primary server IP address is: 192.168.0.32

DNS primary server IP address is: 192.168.0.32

This sample script defines objects similar to those described in the "Sample Script for DOCSIS Modems and Computers" section.

To run this script, in the Network Registrar nrcmd program, enter:

<NR_HOME>/usrbin/nrcmd -N <username> -P <password> -b < bpr_cnr_pktcbl_sample_config.nrcmd


hometocprevnextglossaryfeedbacksearchhelp

Posted: Thu Jun 30 11:06:56 PDT 2005
All contents are Copyright © 1992--2005 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.