EM setup information is presented in the following sections:
To enable the EM to communicate with the Cisco Catalyst 8500 routers, certain configuration tasks must be performed on the router. Until these configuration tasks are completed, the EM cannot contact the routers and no management can begin.
Before you can start using C8500MGR to manage Cisco Catalyst 8500 routers, you must meet the following requirements:
To meet these requirements, perform the following tasks from a console window, as appropriate.
Step 2 If the router does not have a configured management Ethernet port, enter commands as follows:
The Sun machine running the EM should now be able to ping the router.
Step 3 If the router is not SNMP-manageable, enter commands as follows:
Step 4 If the router does not currently accept Telnet sessions, enter commands as follows:
The preceding configuration assumes you have not configured usernames in the Cisco IOS software.
EM traps should be enabled so that the router sends traps to the EM server at the appropriate IP address.
To enable traps, proceed as follows:
Step 2 Enter the following:
Step 3 Enter the enable password.
Step 4 Enter the following:
To obtain help when using Cisco IOS commands, enter the command in question followed by a question mark.
Configuring a TFTP server enables the Configuration Backup/Restore to operate. Setting up a workstation as a TFTP server is described in the following sections:
Configuring the C8500MGR server as a TFTP server is optional. You can alternatively choose to use a different machine as the TFTP server, or not use the backup/restore functionality at all. If you choose to use another workstation as a TFTP server, make sure that backup files are empty. You also need the appropriate permissions set to allow read and write access. Backup files have the filename C8500MGRaa.bb.cc.dd, where aa.bb.cc.dd is the IP address of the router. A backup file is created for the active Cisco Catalyst 8500 router.
When the manager is set up as the TFTP server, the EM ensure that the backup files exist and have the correct permissions.
TFTP enables you to transfer files to and from remote systems. The EM Configuration Backup/Restore window allows you to back up and restore the EM configuration. TFTP transfers the configuration files from a device to your system through the network.
The TFTP daemon must be enabled in order for the EM to upload or download a configuration file. If you are using standard Sun software, verify that the TFTP daemon (tftpd) is enabled as follows:
Step 2 Edit the /etc/inetd.conf file using a text editor (such as vi).
Step 3 Look in the /etc/inetd.conf file for the line that invokes tftpd. When the line is commented out (starts with a pound sign # as in the following example), use a text editor to delete the pound sign.
Step 4 Save the changes in the edited file and exit.
Step 5 Reboot the system.
Step 6 Verify that the TFTP daemon is enabled by entering:
Output similar to the following appears:
If there is no output, tftpd is not enabled. For additional information on TFTP, refer to the UNIX main pages on tftp and tftpd.
The tftpboot directory stores configuration files from the EM managed routers. To create the tftpboot directory, do the following:
Step 2 Modify the permissions by entering the following:
All users accessing the tftpboot directory will have read, write, and execute permissions.
Starting the Cisco EMF manager system automatically starts the EM. To start the Cisco EMF manager system, follow these steps. If Cisco EMF is already started, proceed to step 4.
Step 2 Log in as a root user.
Step 3 Start the Cisco EMF manager system by entering the following:
(Replace CEMF_ROOT with the name of the directory where Cisco EMF is installed.)
The Cisco EMF and C8500MGR processes start.
Any type of user (not only root users) can start a Cisco EMF user session.
Step 4 To start a Cisco EMF/C8500MGR user session, enter commands as follows:
(Replace CEMF_ROOT with the name of the directory where Cisco EMF is installed.)
Step 5 Enter a username and a password. (The default username is admin, and the default password is admin.)
To stop only the Cisco EMF/EM user session, do the following:
When you close the Launchpad window, your user session is terminated.
Step 2 Confirm your decision to quit the Cisco EMF manager system by clicking OK.
The Cisco EMF/EM user session ends.
To check the status of Cisco EMF/EM, enter commands as follows:
(Replace CEMF_ROOT with the name of the directory where Cisco EMF is installed.)
A message appears indicating that the Cisco EMF manager system is running. A list of running processes is also displayed. If Cisco EMF is not active, a message appears indicating that the Cisco EMF manager system is not running.
When you run a Cisco EMF query, verify that the ciscoERCon process is running. If the ciscoERCon process is not running, the EM may be installed incorrectly and may need to be reinstalled.
Posted: Thu Mar 20 16:40:50 PST 2003
All contents are Copyright © 1992--2002 Cisco Systems, Inc. All rights reserved.