cc/td/doc/product/ong/mplanner
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table Of Contents

Card Types


Card Types


This appendix provides a list of interface and card types supported in Cisco TransportPlanner, as well as the corresponding Cisco product ID (Tables B-1 to B-29).


Note The card names in this appendix designated with "_C" or "_L" appear in Cisco TransportPlanner with a "_y" designation before network analysis. The "_y" designation indicates that Cisco TransportPlanner will use either a C- or L-band card, depending on the band selected during project creation.


Table B-1 OC-192/STM-64 (9.953 Gbps) 

Interface Type
Card Type
Protection Type
Product ID

Transponder

TXP_MR_10E_C and TXP_MR_10E_L with EFEC1

Client 1+1

Y-Cable

15454-10E-L1-C= (C band)

15454-10E-L1-L= (L band)

Transponder

TXP_MR_10E_C and TXP_MR_10E_L with FEC2

Client 1+1

Y-Cable

15454-10E-L1-C= (C band)

15454-10E-L1-L= (L band)

Transponder

TXP_MR_10E_C and TXP_MR_10E_L without FEC

Client 1+1

Y-Cable

15454-10E-L1-C= (C band)

15454-10E-L1-L= (L band)

Transponder

TXP_MR_10E with EFEC

Client 1+1

Y-Cable

15454-10E-L1-xx.y= (C band)

15454-10E-L1-xx.y= (L band)

Transponder

TXP_MR_10E with FEC

Client 1+1

Y-Cable

15454-10E-L1-xx.y= (C band)

15454-10E-L1-xx.y= (L band)

Transponder

TXP_MR_10E without FEC

Client 1+1

Y-Cable

15454-10E-L1-xx.y= (C band)

15454-10E-L1-xx.y= (L band)

Transponder

TXP_MR_10G with FEC

Client 1+1

Y-Cable

15454-10T-L1-xx.y=

Transponder

TXP_MR_10G without FEC

Client 1+1

Y-Cable

15454-10T-L1-xx.y=

Line Card

OC-192 LR

STM-64 LR

Client 1+1

15454-192L-1-xx.y= (ANSI)

15454E-64L-xx.y= (ETSI)

1 Enhanced forward error correction.

2 Forward error correction.


Table B-2 OC-48/STM-16 (2.488 Gbps) 

Interface Type
Card Type
Protection Type
Product ID

Transponder

TXP_MR_2.5G

TXPP_MR_2.5G with FEC

Client 1+1

Y-Cable

Fiber-Switched

15454-MR-L1-xx.y= (Unprot)

15454-MRP-L1-xx.y= (Prot)

Transponder

TXP_MR_2.5G

TXPP_MR_2.5G without FEC

Client 1+1

Y-Cable

Fiber-Switched

15454-MR-L1-xx.y= (Unprot)

15454-MRP-L1-xx.y= (Prot)

Transponder

MXP_2.5_10E_C and MXP_2.5_10E_L with EFEC

Client 1+1

Y-Cable

15454-10ME-L1-C= (C band)

15454-10ME-L1-L= (L band)

Transponder

MXP_2.5_10E_C and MXP_2.5_10E_L with FEC

Client 1+1

Y-Cable

15454-10ME-L1-C= (C band)

15454-10ME-L1-L= (L band)

Transponder

MXP_2.5_10E with EFEC

Client 1+1

Y-Cable

15454-10ME-xx.y=

Transponder

MXP_2.5_10ET with FEC

Client 1+1

Y-Cable

15454-10ME-xx.y=

Transponder

MXP_2.5_10G with FEC

Client 1+1

Y-Cable

15454-10M-L1-xx.y=

Transponder

MXP_2.5_10G without FEC

Client 1+1

Y-Cable

15454-10M-L1-xx.y=

Line Card

OC48ELR / SMT-16ELR

Client 1+1

15454-O48E-1-xx.y (ANSI)

15454E-EL16HSxxyy= (ETSI)

Transponder

ADM-10G

Client 1+1

Y-Cable

Fiber-Switched

15454-ADM-10G = (Unprot)

15454-ADM-10G = (Prot)


Table B-3 OC-12/STM-4 (622 Mbps) 

Interface Type
Card Type
Protection Type
Product ID

Transponder

TXP_MR_2.5G

TXPP_MR_2.5G with FEC

Client 1+1

Y-Cable

Fiber-Switched

15454-MR-L1-xx.y= (Unprot)

15454-MRP-L1-xx.y= (Prot)

Transponder

TXP_MR_2.5G

TXPP_MR_2.5G without FEC

Client 1+1

Y-Cable

Fiber-Switched

15454-MR-L1-xx.y= (Unprot)

15454-MRP-L1-xx.y= (Prot)

Transponder

ADM-10G

Client 1+1

Y-Cable

Fiber-Switched

15454-ADM-10G = (Unprot)

15454-ADM-10G = (Prot)


Table B-4 OC-3/STM-1 (155 Mbps) 

Interface Type
Card Type
Protection Type
Product ID

Transponder

TXP_MR_2.5G

TXPP_MR_2.5G with FEC

Client 1+1

Y-Cable

Fiber-Switched

15454-MR-L1-xx.y= (Unprot)

15454-MRP-L1-xx.y= (Prot)

Transponder

TXP_MR_2.5G

TXPP_MR_2.5G without FEC

Client 1+1

Y-Cable

Fiber-Switched

15454-MR-L1-xx.y= (Unprot)

15454-MRP-L1-xx.y= (Prot)

Transponder

ADM-10G

Client 1+1

Y-Cable

Fiber-Switched

15454-ADM-10G = (Unprot)

15454-ADM-10G = (Prot)


Table B-5 10 Gigabit Ethernet Wide Area Network ATM Physical Layer (10GE WAN PHY) (9.953 Gbps) 

Interface Type
Card Type
Protection Type
Product ID

Transponder

TXP_MR_10E_C and TXP_MR_10E_L with EFEC

Client 1+1

Y-Cable

15454-10E-L1-C= (C band)

15454-10E-L1-L= (L band)

Transponder

TXP_MR_10E_C and TXP_MR_10E_L with FEC

Client 1+1

Y-Cable

15454-10E-L1-C= (C band)

15454-10E-L1-L= (L band)

Transponder

TXP_MR_10E_C and TXP_MR_10E_L without FEC

Client 1+1

Y-Cable

15454-10E-L1-C= (C band)

15454-10E-L1-L= (L band)

Transponder

TXP_MR_10E with EFEC

Client 1+1

Y-Cable

15454-10E-L1-C= (C band)

15454-10E-L1-L= (L band)

Transponder

TXP_MR_10E with FEC

Client 1+1

Y-Cable

15454-10E-L1-C= (C band)

15454-10E-L1-L= (L band)

Transponder

TXP_MR_10E without FEC

Client 1+1

Y-Cable

15454-10E-L1-C= (C band)

15454-10E-L1-L= (L band)

Transponder

TXP_MR_10G with FEC

Client 1+1

Y-Cable

15454-10T-L1-xx.y=

Transponder

TXP_MR_10G without FEC

Client 1+1

Y-Cable

15454-10T-L1-xx.y=


Table B-6 10 Gigabit Ethernet Local Area Network ATM Physical Layer (10GE LAN PHY)(10.3 Gbps) 

Interface Type
Card Type
Protection Type
Product ID

Transponder

TXP_MR_10E_C and TXP_MR_10E_L with EFEC

Client 1+1

Y-Cable

15454-10E-L1-C= (C band)

15454-10E-L1-L= (L band)

Transponder

TXP_MR_10E_C and TXP_MR_10E_L with FEC

Client 1+1

Y-Cable

15454-10E-L1-C= (C band)

15454-10E-L1-L= (L band)

Transponder

TXP_MR_10E_C and TXP_MR_10E_L without FEC

Client 1+1

Y-Cable

15454-10E-L1-C= (C band)

15454-10E-L1-L= (L band)

Transponder

TXP_MR_10E with EFEC

Client 1+1

Y-Cable

15454-10E-L1-C= (C band)

15454-10E-L1-L= (L band)

Transponder

TXP_MR_10E with FEC

Client 1+1

Y-Cable

15454-10E-L1-C= (C band)

15454-10E-L1-L= (L band)

Transponder

TXP_MR_10E without FEC

Client 1+1

Y-Cable

15454-10E-L1-C= (C band)

15454-10E-L1-L= (L band)

Transponder

TXP_MR_10G with FEC

Client 1+1

Y-Cable

15454-10T-L1-xx.y=

Transponder

TXP_MR_10G without FEC

Client 1+1

Y-Cable

15454-10T-L1-xx.y=

Transponder

10GE_XP with point-to-point traffic demand

XFPs with Ethernet aggregated traffic demand

Client 1+1

Y-Cable

15454-10GE-XP = (Unprot)

15454-10GE-XP = (Prot)


Table B-7 Gigabit Ethernet (1.25Gbps) 

Interface Type
Card Type
Protection Type
Product ID

Transponder

MXP_MR_2.5G

MXPP_MR_2.5G

Client 1+1

Y-Cable

Fiber-Switched

15454-DM-L1-xx.y= (Unprot)

15454-DMP-L1-xx.y= (Prot)

Transponder

MXP_MR_10DME with EFEC

Client 1+1

Y-Cable

15454-10DME-C= (C band)

15454-10DME-L= (L band)

Transponder

MXP_MR_10DME with FEC

Client 1+1

Y-Cable

15454-10DME-C= (C band)

15454-10DME-L= (L band)

Transponder

MXP_MR_10DME without FEC

Client 1+1

Y-Cable

15454-10DME-C= (C band)

15454-10DME-L= (L band)

Transponder

TXP_MR_2.5G

TXPP_MR_2.5G with FEC

Client 1+1

Y-Cable

Fiber-Switched

15454-MR-L1-xx.y= (Unprot)

15454-MRP-L1-xx.y= (Prot)

Transponder

TXP_MR_2.5G

TXPP_MR_2.5G without FEC

Client 1+1

Y-Cable

Fiber-Switched

15454-MR-L1-xx.y= (Unprot)

15454-MRP-L1-xx.y= (Prot)

Pluggable

GE DWDM GBIC

Client 1+1

15454-GBIC-xx.y=

Transponder

GE_XP with point-to-point traffic demand configured on CTC as 10GE MXP

GE XP-O with point to point traffic demand and if configured on Cisco Transport Controller (CTC) as 20GE MXP

XFPs with Ethernet aggregated traffic demand

Client 1+1

Y-Cable

Fiber-Switched

15454-GE-XP = (Unprot)

15454-GE-XP = (Prot)

Transponder

ADM-10G

Client 1+1

Y-Cable

Fiber-Switched

15454-ADM-10G = (Unprot)

15454-ADM-10G = (Prot)


Table B-8 Fast Ethernet (100 Mbps)

Interface Type
Card Type
Protection Type
Product ID

Transponder

TXP_MR_2.5G

TXPP_MR_2.5G 2R

Client 1+1

Y-Cable

Fiber-Switched

15454-MR-L1-xx.y= (Unprot)

15454-MRP-L1-xx.y= (Prot)


Table B-9 Fiber Channel 10G (10.5 Gbps) 

Interface Type
Card Type
Protection Type
Product ID

Transponder

TXP_MR_10E_C and TXP_MR_10E_L with EFEC

Client 1+1

Y-Cable

15454-10E-L1-C= (C band)

15454-10E-L1-L= (L band)

Transponder

TXP_MR_10E_C and TXP_MR_10E_L with FEC

Client 1+1

Y-Cable

15454-10E-L1-C= (C band)

15454-10E-L1-L= (L band)

Transponder

TXP_MR_10E_C and TXP_MR_10E_L without FEC

Client 1+1

Y-Cable

15454-10E-L1-C= (C band)

15454-10E-L1-L= (L band)

Transponder

TXP_MR_10E with EFEC

Client 1+1

Y-Cable

15454-10E-L1-C= (C band)

15454-10E-L1-L= (L band)

Transponder

TXP_MR_10E with FEC

Client 1+1

Y-Cable

15454-10E-L1-C= (C band)

15454-10E-L1-L= (L band)

Transponder

TXP_MR_10E without FEC

Client 1+1

Y-Cable

15454-10E-L1-C= (C band)

15454-10E-L1-L= (L band)

Transponder

TXP_MR_10E

TXP_MR_10E_y

Client 1+1

Y-Cable

15454-10E-L1-C= (C band)

15454-10E-L1-L= (L band)


Table B-10 Fiber Channel 4G (4.25 Gbps) 

Interface Type
Card Type
Protection Type
Product ID

Transponder

MXP_MR_10DME with EFEC

Client 1+1

Y-Cable

15454-10DME-C= (C band)

15454-10DME-L= (L band)

Transponder

MXP_MR_10DME with FEC

Client 1+1

Y-Cable

15454-10DME-C= (C band)

15454-10DME-L= (L band)

Transponder

MXP_MR_10DME without FEC

Client 1+1

Y-Cable

15454-10DME-C= (C band)

15454-10DME-L= (L band)


Table B-11 Fiber Channel 2G (2.125 Gbps) 

Interface Type
Card Type
Protection Type
Product ID

Transponder

MXP_MR_2.5G

MXPP_MR_2.5G

Client 1+1

Y-Cable

Fiber-Switched

15454-DM-L1-xx.y= (Unprot)

15454-DMP-L1-xx.y= (Prot)

Transponder

MXP_MR_10DME with EFEC

Client 1+1

Y-Cable

15454-10DME-C= (C band)

15454-10DME-L= (L band)

Transponder

MXP_MR_10DME with FEC

Client 1+1

Y-Cable

15454-10DME-C= (C band)

15454-10DME-L= (L band)

Transponder

MXP_MR_10DME without FEC

Client 1+1

Y-Cable

15454-10DME-C= (C band)

15454-10DME-L= (L band)

Transponder

TXP_MR_2.5G

TXPP_MR_2.5G with FEC

Client 1+1

Y-Cable

Fiber-Switched

15454-MR-L1-xx.y= (Unprot)

15454-MRP-L1-xx.y= (Prot)

Transponder

TXP_MR_2.5G

TXPP_MR_2.5G without FEC

Client 1+1

Y-Cable

Fiber-Switched

15454-MR-L1-xx.y= (Unprot)

15454-MRP-L1-xx.y= (Prot)


Table B-12 Fiber Channel 1G (1.062 Gbps) 

Interface Type
Card Type
Protection Type
Product ID

Transponder

MXP_MR_2.5G

MXPP_MR_2.5G

Client 1+1

Y-Cable

Fiber-Switched

15454-DM-L1-xx.y= (Unprot)

15454-DMP-L1-xx.y= (Prot)

Transponder

MXP_MR_10DME with EFEC

Client 1+1

Y-Cable

15454-10DME-C= (C band)

15454-10DME-L= (L band)

Transponder

MXP_MR_10DME with FEC

Client 1+1

Y-Cable

15454-10DME-C= (C band)

15454-10DME-L= (L band)

Transponder

MXP_MR_10DME without FEC

Client 1+1

Y-Cable

15454-10DME-C= (C band)

15454-10DME-L= (L band)

Transponder

TXP_MR_2.5G

TXPP_MR_2.5G with FEC

Client 1+1

Y-Cable

Fiber-Switched

15454-MR-L1-xx.y= (Unprot)

15454-MRP-L1-xx.y= (Prot)

Transponder

TXP_MR_2.5G

TXPP_MR_2.5G without FEC

Client 1+1

Y-Cable

Fiber-Switched

15454-MR-L1-xx.y= (Unprot)

15454-MRP-L1-xx.y= (Prot)


Table B-13 2 Gbps Fiber Connectivity (2.125 Gbps) 

Interface Type
Card Type
Protection Type
Product ID

Transponder

MXP_MR_2.5G

MXPP_MR_2.5G

Client 1+1

Y-Cable

Fiber-Switched

15454-DM-L1-xx.y= (Unprot)

15454-DMP-L1-xx.y= (Prot)

Transponder

MXP_MR_10DME with EFEC

Client 1+1

Y-Cable

15454-10DME-C= (C band)

15454-10DME-L= (L band)

Transponder

MXP_MR_10DME with FEC

Client 1+1

Y-Cable

15454-10DME-C= (C band)

15454-10DME-L= (L band)

Transponder

MXP_MR_10DME without FEC

Client 1+1

Y-Cable

15454-10DME-C= (C band)

15454-10DME-L= (L band)

Transponder

TXP_MR_2.5G

TXPP_MR_2.5G with FEC

Client 1+1

Y-Cable

Fiber-Switched

15454-MR-L1-xx.y= (Unprot)

15454-MRP-L1-xx.y= (Prot)

Transponder

TXP_MR_2.5G

TXPP_MR_2.5G without FEC

Client 1+1

Y-Cable

Fiber-Switched

15454-MR-L1-xx.y= (Unprot)

15454-MRP-L1-xx.y= (Prot)


Table B-14 FICON-1G (1.062 Gbps) 

Interface Type
Card Type
Protection Type
Product ID

Transponder

MXP_MR_2.5G

MXPP_MR_2.5G

Client 1+1

Y-Cable

Fiber-Switched

15454-DM-L1-xx.y= (Unprot)

15454-DMP-L1-xx.y= (Prot)

Transponder

MXP_MR_10DME with EFEC

Client 1+1

Y-Cable

15454-10DME-C= (C band)

15454-10DME-L= (L band)

Transponder

MXP_MR_10DME with FEC

Client 1+1

Y-Cable

15454-10DME-C= (C band)

15454-10DME-L= (L band)

Transponder

MXP_MR_10DME without FEC

Client 1+1

Y-Cable

15454-10DME-C= (C band)

15454-10DME-L= (L band)

Transponder

TXP_MR_2.5G

TXPP_MR_2.5G with FEC

Client 1+1

Y-Cable

Fiber-Switched

15454-MR-L1-xx.y= (Unprot)

15454-MRP-L1-xx.y= (Prot)

Transponder

TXP_MR_2.5G

TXPP_MR_2.5G without FEC

Client 1+1

Y-Cable

Fiber-Switched

15454-MR-L1-xx.y= (Unprot)

15454-MRP-L1-xx.y= (Prot)


Table B-15 Enterprise System Connection (ESCON) (200 Mbps) 

Interface Type
Card Type
Protection Type
Product ID

Transponder

MXP_MR_2.5G

MXPP_MR_2.5G

Client 1+1

Y-Cable

Fiber-Switched

15454-DM-L1-xx.y= (Unprot)

15454-DMP-L1-xx.y= (Prot)

Transponder

TXP_MR_2.5G

TXPP_MR_2.5G 2R

Client 1+1

Y-Cable

Fiber-Switched

15454-MR-L1-xx.y= (Unprot)

15454-MRP-L1-xx.y= (Prot)


Table B-16 ISC-3 Compatibility Mode (1.062 Gbps) 

Interface Type
Card Type
Protection Type
Product ID

Transponder

TXP_MR_2.5G without FEC

Client 1+1

15454-MR-L1-xx.y= (Unprot)

15454-MRP-L1-xx.y= (Prot)

Transponder

MXP_MR_10DME with EFEC

Client 1+1

15454-10DME-C= (C band)

15454-10DME-L= (L band)

Transponder

MXP_MR_10DME with FEC

Client 1+1

15454-10DME-C= (C band)

15454-10DME-L= (L band)

Transponder

MXP_MR_10DME without FEC

Client 1+1

15454-10DME-C= (C band)

15454-10DME-L= (L band)


Table B-17 ISC-Peer 2R 

Interface Type
Card Type
Protection Type
Product ID

Transponder

TXP_MR_2.5G 2R

Client 1+1

15454-MR-L1-xx.y= (Unprot)

15454-MRP-L1-xx.y= (Prot)


Table B-18 ISC-3 Peer-1G (1.062 Gbps) 

Interface Type
Card Type
Protection Type
Product ID

Transponder

MXP_MR_10DME with EFEC

Client 1+1

Y-Cable

15454-10DME-C= (C band)

15454-10DME-L= (L band)

Transponder

MXP_MR_10DME with FEC

Client 1+1

Y-Cable

15454-10DME-C= (C band)

15454-10DME-L= (L band)

Transponder

MXP_MR_10DME without FEC

Client 1+1

Y-Cable

15454-10DME-C= (C band)

15454-10DME-L= (L band)


Table B-19 ISC-3 Peer-2G (2.125 Gbps) 

Interface Type
Card Type
Protection Type
Product ID

Transponder

MXP_MR_10DME with EFEC

Client 1+1

Y-Cable

15454-10DME-C= (C band)

15454-10DME-L= (L band)

Transponder

MXP_MR_10DME with FEC

Client 1+1

Y-Cable

15454-10DME-C= (C band)

15454-10DME-L= (L band)

Transponder

MXP_MR_10DME without FEC

Client 1+1

Y-Cable

15454-10DME-C= (C band)

15454-10DME-L= (L band)


Table B-20 Sysplex External Throughput Rate (8 Mbps)

Interface Type
Card Type
Protection Type
Product ID

Transponder

TXP_MR_2.5G 2R

Client 1+1

15454-MR-L1-xx.y= (Unprot)

15454-MRP-L1-xx.y= (Prot)


Table B-21 Sysplex Control Link Oscillator (8 Mbps)

Interface Type
Card Type
Protection Type
Product ID

Transponder

TXP_MR_2.5G 2R

Client 1+1

15454-MR-L1-xx.y= (Unprot)

15454-MRP-L1-xx.y= (Prot)


Table B-22 Serial Data Input

Interface Type
Card Type
Protection Type
Product ID

Transponder

TXP_MR_2.5G

TXPP_MR_2.5G 2R

Client 1+1

Y-Cable

Fiber-Switched

15454-MR-L1-xx.y= (Unprot)

15454-MRP-L1-xx.y= (Prot)


Table B-23 Digital Video Broadcast-Asynchronous Serial Interface

Interface Type
Card Type
Protection Type
Product ID

Transponder

TXP_MR_2.5G TXPP_MR_2.5G 2R

Client 1+1

Y-Cable

Fiber-Switched

15454-MR-L1-xx.y= (Unprot)

15454-MRP-L1-xx.y= (Prot)


Table B-24 D1-Video (270 Mbps)

Interface Type
Card Type
Protection Type
Product ID

Transponder

TXP_MR_2.5G TXPP_MR_2.5G 2R

Client 1+1

Y-Cable

Fiber-Switched

15454-MR-L1-xx.y= (Unprot)

15454-MRP-L1-xx.y= (Prot)


Table B-25 High Definition Television (HDTV) (1.48 Gbps)

Interface Type
Card Type
Protection Type
Product ID

Transponder

TXP_MR_2.5G TXPP_MR_2.5G 2R

Client 1+1

Y-Cable

Fiber-Switched

15454-MR-L1-xx.y= (Unprot)

15454-MRP-L1-xx.y= (Prot)


Table B-26 DV-6000 (2.38 Gbps)

Interface Type
Card Type
Protection Type
Product ID

Transponder

TXP_MR_2.5G TXPP_MR_2.5G 2R

Client 1+1

Y-Cable

Fiber-Switched

15454-MR-L1-xx.y= (Unprot)

15454-MRP-L1-xx.y= (Prot)


Table B-27 2R Any Rate

Interface Type
Card Type
Protection Type
Product ID

Transponder

TXP_MR_2.5G TXPP_MR_2.5G 2R

Client 1+1

Y-Cable

Fiber-Switched

15454-MR-L1-xx.y= (Unprot)

15454-MRP-L1-xx.y= (Prot)


Table B-28 ONS 15530 2.5G ITU-T

Interface Type
Card Type
Protection Type
Product ID

TXP

MR MM TXP

MR SM TXP

MR MM TXP with splitter

MR SM TXP with splitter

Client 1+1

Fiber-Switched

15530-TSP1-xx21 (MM Unprot)

15530-TSP1-xx22 (SM Unprot)

15530-TSP1-xx11 (MM Prot)

15530-TSP1-xx12 (SM Prot)

LC

2.5-Gbps Aggregation

2.5-Gbps Aggregation with splitter

Client 1+1

Fiber-Switched

15530-ITU3-xx20 (Unprot)

15530-ITU3-xx10 (Prot)


Table B-29 ONS 15530 10G ITU-T

Interface Type
Card Type
Protection Type
Product ID

LC

10-Gbps Aggregation

10-Gbps Aggregation with splitter

Client 1+1

Fiber-Switched

15530-ITU2-xx20 (Unprot)

15530-ITU2-xx10 (Prot)

MXP

Data Muxponder

Data Muxponder with splitter

Client 1+1

Fiber-Switched

15530-MSMP-xx22 (Unprot)

15530-MSMP-xx12 (Prot)



hometocprevnextglossaryfeedbacksearchhelp

Posted: Thu Oct 18 08:56:57 PDT 2007
All contents are Copyright © 1992--2007 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.