cc/td/doc/product/ong/15400/r85docs
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table Of Contents

Error Messages


Error Messages



Note The terms "Unidirectional Path Switched Ring" and "UPSR" may appear in Cisco literature. These terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring configuration. Rather, these terms, as well as "Path Protected Mesh Network" and "PPMN," refer generally to Cisco's path protection feature, which may be used in any topological network configuration. Cisco does not recommend using its path protection feature in any particular topological network configuration.


This chapter lists the Cisco ONS 15454, Cisco 15454 SDH, Cisco ONS 15600, Cisco 15600 SDH, Cisco ONS 15310-CL, and Cisco ONS 15310-MA error messages. The error dialog box in Figure 4-1 consists of three parts: the error title, error ID, and error message. The table lists two types of messages: error messages (EID-nnnn) and warning messages (WID-nnnn). Error messages are alerts that an unexpected or undesirable operation has occurred which either indicates the risk of loss of traffic or an inability to properly manage devices in the network. Warnings are alerts that the requested operation could lead to an error. Warnings are sometimes used to convey important information.

Figure 4-1 Error Dialog Box

Table 4-1 gives a list of all error or warning message numbers, the messages, and a brief description of each message.

Table 4-1 Error Messages 

Error Warning ID
Error Warning Message
Description

EID-0

Invalid error ID.

The error ID is invalid.

EID-1

A null pointer encountered in {0}.

Cisco Transport Controller (CTC) encountered a null pointer in the area described by the specified item.

EID-1000

The host name of the network element cannot be resolved to an address.

Refer to the error message text.

EID-1001

Unable to launch CTC due to applet security restrictions.

Please review the installation instructions to make sure that the CTC launcher is given the permissions it needs.

Note that you must exit and restart your browser in order for the new permissions to take effect.

Refer to the error message text.

EID-1002

The host name (e.g., for the network element) was successfully resolved to its address, but no route can be found through the network to reach the address.

The node is not reachable from CTC client station.

EID-1003

An error was encountered while attempting to launch CTC.
{0}

Unexpected exception or error while launching CTC from the applet.

EID-1004

Problem Deleting CTC Cache: {0} {1}

Unable to delete the CTC cached JARs, because another application may have the JAR files running; for example, another instance of CTC.

EID-1005

An error occurred while writing to the {0} file.

CTC encountered an error while writing to log files, preference files, etc.

EID-1006

The URL used to download {0} is malformed.

The URL used to download the specified JAR file is incorrect.

EID-1007

An I/O error occurred while trying to download {0}.

An input or output exception was encountered when CTC tried to download the specified JAR file.

EID-1018

Password shall not contain the associated user-ID.

The password is invalid.

EID-1019

Could not create {0}.
Please enter another filename.

CTC could not create the file due to an invalid filename.

EID-1020

Fatal exception occurred, exiting CTC.
Unable to switch to the Network view.

CTC was unable to switch from the node or card view to the network view and is now shutting down.

EID-1021

Unable to navigate to {0}.

CTC could not display the requested view (node or network).

EID-1022

An IOS session cannot be opened right now with this slot. Most likely someone else (using a different CTC) already has a session opened with this slot. Please try again later.

Refer to the error message text.

EID-1023

This IOS session has been terminated.
Terminations are caused when the session has timed out, the card resets, there is already a session with the slot, or password configuration is required.

Refer to the error message text.

EID-1025

Unable to create Help Broker.

CTC was unable to create the help broker for the online help.

EID-1026

Error found in the Help Set file.

CTC encountered an error in the online help file.

EID-1027

Unable to locate help content for Help ID: "{0}".

CTC was unable to locate the content for the help ID.

EID-1028

Error saving table. {0}

There was an error while saving the specified table.

EID-1031

CTC cannot locate the online user manual files. The files may have been moved, deleted, or not installed. To install online user manuals, run the CTC installation wizard on the software or documentation CD.

Refer to the error message text.

EID-1032

CTC cannot locate Acrobat Reader. If Acrobat Reader is not installed, you can install the Reader using the CTC installation wizard provided on the software or documentation CD.

Refer to the error message text.

EID-1035

CTC experienced an I/O error while working with the log files. Usually this means that the computer has run out of disk space. This problem may or may not cause CTC to stop responding. Ending this CTC session is recommended, but not required.

Refer to the error message text.

WID-1036

WARNING: Deleting the CTC cache may cause any CTC running on this system to behave in an unexpected manner.

Refer to the warning message text.

EID-1037

Could not open {0}. Please enter another filename.

Invalid file name. CTC is unable to open the specified file. Ensure that the file exists and the filename was typed correctly.

EID-1038

The file {0} does not exist.

The specified file does not exist.

EID-1039

The version of the browser applet does not match the version required by the network element. Please close and restart your browser in order to launch the Cisco Transport Controller.

Refer to the error message text.

WID-1041

An error occurred while closing the {0} connection.

CTC encountered an error while closing the specified connection.

WID-1042

You have selected Java version {0}.
This version is outside of the recommended range and may cause an unpredictable behavior of the software.
Do you wish to continue?

Refer to the warning message text.

EID-1043

Error writing to file: {0}.
This might be caused by a directory permission, quota or disk volume full issue.

Check for possible causes and try again.

WID-1044

Warning: there is a discrepancy in the build timestamp between the NE cached jar file ({0}) and the NE ({1}).
Your CTC jar cache should be emptied.

Refer to the warning message text.

EID-1046

Selected CTC version ({0}) must be greater than or equal{to the login NE version ({1}).

The CTC software version must be greater than or equal to the software version on the node being managed.

EID-2001

No rolls were selected. {0}

No rolls were selected for the bridge and roll.

EID-2002

The roll must be completed or canceled before it can be deleted.

You cannot delete the roll unless it has been completed or cancelled.

EID-2003

An error occurred while deleting the roll.
{0}

There was an error when CTC tried to delete the roll.

EID-2004

No Cisco IOS slot was selected.

You did not select a Cisco IOS slot.

EID-2005

CTC cannot find the online help files for {0}.
The files might have been moved, deleted, or not installed.
To install online help, run the setup program on the software CD.

CTC cannot find the online help files for the specified window. The files might have been moved, deleted, or not installed. To install online help, run the setup program on the software CD.

EID-2006

An error occurred while editing the circuit(s).
{0}
{1}.

An error occurred when CTC tried to open the circuit for editing.

EID-2007

The preferences could not be saved.

CTC cannot save the preferences.

EID-2008

The circuit preferences could not be saved:
{0}

CTC cannot find the file needed to save the circuit preferences.

EID-2009

CTC was unable to download the package:
{0}

Refer to the error message text.

EID-2010

An error occurred while deleting the destination.

CTC could not delete the destination.

EID-2011

The circuit could not be destroyed.

CTC could not destroy the circuit.

EID-2012

The reverse circuit could not be destroyed.

CTC could not reverse the circuit destroy.

EID-2013

The circuit creation failed.
The circuit creation cannot proceed due to changes in the network which affected the circuit(s) being created.
The dialog box will close. Please try again.

Refer to the error message text.

EID-2014

No circuit(s) were selected.
{0}

You must select a circuit to complete this function.

EID-2015

The circuit {0} cannot be deleted because it has one or more rolls.

You must delete the rolls in the circuit before deleting the circuit itself.

EID-2016

The circuit deletion failed.

CTC could not delete the tunnel as there are circuits that use the tunnel.

EID-2017

An error occurred while mapping the circuit.
{0}

There was an error mapping the circuit.

EID-2018

The circuit roll failed.
The circuit must be in the DISCOVERED state in order to perform a roll.

There was a failure in circuit roll. Change the circuit state to DISCOVERED and proceed.

EID-2019

The circuit roll failed.
Bridge and roll is not supported on DWDM circuits.

Refer to the error message text.

EID-2020

The circuit roll failed.
The two circuits must have the same direction.

Refer to the error message text.

EID-2021

The circuit roll failed.
The two circuits must have the same size.

Refer to the error message text.

EID-2022

The circuit roll failed.
A maximum of two circuits can be selected for a bridge and roll operation.

Refer to the error message text.

EID-2023

CTC was unable to create a new user account.

Refer to the error message text.

EID-2024

An error occurred during node selection.

There was an error during node selection.

EID-2025

This feature cannot be used. Verify that each endpoint of this circuit is running software that supports this feature.

Refer to the error or warning message text. For example, this error is generated from the node view Provisioning> WDM-ANS> tabs to indicate that the selected ring type is not supported by the endpoints of the circuit. Another example is the Provisioning> VLAN tabs in card view (Ethernet card only), where it indicates that the back-end spanning tree protocol (STP) disabling is not supported.

EID-2026

The {0} request could not be applied.
{1}

Error occurred while attempting to switch a path protection.

EID-2027

An error occurred while deleting the circuit drop.

CTC could not delete the circuit drop.

EID-2028

An error occurred while removing the circuit node.

CTC could not remove the circuit node.

EID-2029

The requested operation is not supported.

The task you are trying to complete is not supported by CTC.

EID-2030

An error occurred during provisioning.

There was an error during provisioning.

EID-2031

An error occurred while adding the node.

There was an error while adding a node.

EID-2032

The circuit could not be renamed.
{0}

CTC could not rename the circuit.

EID-2033

An error occurred during validation.
{0}

There was an internal error while validating the user changes after the Apply button was pressed. This error can occur in the Edit Circuit dialog box or in the BLSR table in the shelf view (rare condition).

EID-2034

Network circuits could not be added:
{0}

Refer to the error message text.

EID-2035

The source and destination nodes are not connected.

Refer to the error message text.

EID-2036

The {0} cannot be deleted.
LAN Access has been disabled on this node and this {0} is needed to access the node.

You cannot delete the DCC/GCC link as it is needed to access the node.

EID-2037

The attribute for {0} cannot be found.

CTC cannot find an attribute for the specified item.

EID-2038

The protection operation is invalid.

The protection operation you tried to execute is invalid.

EID-2040

Please select a node first.

You must select a node before performing the task.

EID-2041

No paths are available on this link. Please make another selection.

You must select a link that has paths available.

EID-2042

This span is not selectable. Only the green spans with an arrow may be selected.

Refer to the error message text.

EID-2043

This node is not selectable. Only the source node and nodes attached to included spans (blue) are selectable. Selecting a selectable node will enable its available outgoing spans.

Refer to the error message text.

EID-2044

This link may not be included in the required list. Constraints only apply to the primary path. Each node may have a maximum of one incoming signal and one outgoing link.

You must select only one link going in and out of a node. Selecting more than one link is contradictory to the path selection algorithm.

EID-2045

This link may not be included in the required list. Only one outgoing link may be included for each node.

Refer to the error message text.

EID-2047

Please enter a valid value for the slot number.

There was an error due to an invalid slot number.

EID-2048

Please enter a valid value for the port number.

There was an error due to an invalid port number.

EID-2050

The new circuit could not be destroyed.

CTC could not destroy the new circuit.

EID-2051

The circuit cannot be downgraded.
{0}

The specified circuit cannot be downgraded.

EID-2052

An error occurred during circuit processing.

There was an error during the circuit processing.

EID-2054

An error occurred while selecting an endpoint.

There was an error during the endpoint selection.

EID-2055

No endpoints are available for this selection. Please make another selection.

This error occurs in the circuit creation dialog only during a race condition that has incorrectly allowed entities without endpoints to be displayed in the combination boxes.

EID-2056

A communication error occurred: {0}

An internal error occurred in Network Alarm tab while synchronizing alarms with the nodes.

EID-2059

An error occurred while deleting the node.
{0}

There was an error during the node deletion.

EID-2060

No PCA circuits were found.

CTC could not find any protection channel access (PCA) circuits for this task.

EID-2061

An error occurred while provisioning the VLAN.

There was an error defining the VLAN.

EID-2062

An error occurred while deleting VLANs.
No VLAN(s) were selected.
Please select a VLAN.

Refer to the error message text.

EID-2063

The default VLAN cannot be deleted.

The selected VLAN is the default VLAN and cannot be deleted.

EID-2064

An error occurred while deleting VLANs.
{0}

There was an error deleting the specified VLAN.

EID-2065

The profile cannot be imported.
The profile "{0}" exists in the editor and the maximum number of copies (ten) exists in the editor.
The import will be aborted. The profile has already been loaded eleven times.

Cannot import the profile because the profile has reached the maximum number of copies in the editor.

EID-2066

The profile could not be stored.
An error occurred while writing to {0}.

CTC encountered an error while trying to store the profile.

EID-2067

An error occurred while writing to the file.
{0}

CTC encountered an error while writing the specified file.

EID-2068

The alarm profile could not be loaded from the node.

CTC encountered an error trying to load the alarm profile from the node.

EID-2069

The file could not be found or an I/O exception occurred.
{0}

Either the specified file was not found, or there was an input/output exception.

EID-2070

The profile could not be deleted.
{0}

There was a failure in deleting the specified profile.

EID-2071

Only one column may be highlighted.

You cannot select more than one column during clone action.

EID-2072

Only one profile may be highlighted.

You cannot select more than one profile.

EID-2073

This column is permanent and cannot be removed.

You cannot delete a permanent column.

EID-2074

Select one or more profiles.

You have not selected any profile or column. Reset operation is done by right-clicking the selected column.

EID-2075

This column is permanent and cannot be reset.

Refer to the error message text.

EID-2077

This column is permanent and cannot be renamed.

Refer to the error message text.

EID-2078

At least two columns must be highlighted.

You cannot compare two profiles unless you select two columns.

EID-2079

The alarm types cannot be loaded into table.
There are no reachable nodes from which the list of alarm types can be loaded.
Please wait until such a node is reachable and try again.

Refer to the error message text.

EID-2080

The node {0} has no profiles.

The specified node does not have any profiles.

EID-2081

An error occurred while removing profile {0} from the node {1}.

There was an error while removing the specified profile from the specified node.

EID-2082

The profile {0} does not exist on the node {1}.

CTC cannot find the specified profile from the specified node.

EID-2083

An error occurred while adding profile {0} to the node {1}.

There was an error adding the specified profile to the specified node.

EID-2085

The profile selection is invalid.
No profiles were selected.

You tried to select an invalid profile. Select another profile.

EID-2086

The node selection is invalid.
No nodes were selected.

You tried to select an invalid node. Select another node.

EID-2087

No profiles were selected.
Please select at least one profile.

Refer to the error message text.

EID-2088

The profile name is invalid.

The profile name cannot be empty.

EID-2089

Too many copies of {0} exist. Please choose another name.

Select a unique name.

EID-2090

No nodes were selected.
Please select the node(s) on which to store the profile(s).

You must select one or more nodes on which you can store the profile.

EID-2091

Unable to switch to the node {0}.

CTC is unable to switch to the specified node.

EID-2092

A general exception error occurred.

CTC encountered a general exception error while trying to complete the task.

EID-2093

The name is too short. It does not have enough characters.
{0}

The name must have a minimum of six characters.

EID-2094

The password and confirmed password fields do not match.

You must make sure the two fields have the same password.

EID-2095

The password is invalid.
{0}

The password you entered is not allowed.

EID-2096

The user must have a security level.

You must have an assigned security level to perform this task.

EID-2097

No user name was specified.

You did not specify a user name.

EID-2099

An error occurred while ring switching.

There was an error during the ring switch.

EID-2100

Please select at least one profile to delete.

You have not selected the profile to delete.

EID-2101

An error occurred while protection switching.

There was an error during the protection switching.

EID-2102

The forced switch could not be removed for some circuits. You must switch these circuits manually.

The forced switch could not be removed for some circuits. You must switch these circuits manually.

EID-2103

An error occurred while upgrading the span.

There was an error during the span upgrade.

EID-2104

The circuits cannot be switched back because one or both nodes are not reachable.

This error occurs during the path protection span upgrade procedure.

EID-2106

The node name cannot be empty.

You must supply a name for the node.

EID-2107

An error occurred while adding {0}. The host is unknown.

There was an error adding the specified item.

EID-2108

{0} is already in the network.

The specified item exists in the network.

EID-2109

The node is already in the current login group.

The node you are trying to add is already present in the current login group.

EID-2110

Please enter a number between 0 and {0}.

You must enter a number in the range between 0 and the specified value.

EID-2111

This node ID is already in use. Please choose another.

Select a node ID that is not in use.

EID-2113

The extension byte for the ring cannot be set.
{0}

CTC cannot set the BLSR/MS-SPRing extension byte.

EID-2114

A card communication failure occurred during the operation.

This error can occur during an attempt to apply a BLSR protection operation to a line.

EID-2115

An error occurred during the operation.
{0}

There was an error in applying the specified operation.

EID-2116

The extension byte setting for the ring is invalid.
{0}

The extension byte set for the specified ring is invalid.

EID-2118

The ring cannot be deleted.
A protection operation is set. All protection operations must be clear for ring to be deleted.

Clear all the protection operations for the ring before deleting it.

EID-2119

{0} cannot be deleted because a protection switch is in effect.
Please clear any protection operations, ensure that the reversion time is not "never" and allow any protection switches to clear before trying again.

Clear all protection operations or switches before deleting the ring.

EID-2120

The following nodes could not be unprovisioned
{0}
Therefore you will need to delete this {1} again later.

The specified nodes could not be unprovisioned. Try deleting this BLSR or MS-SPRing later.

EID-2121

The ring cannot be upgraded.
{0}

CTC cannot upgrade the specified ring.

EID-2122

The ring speed for is inadequate for the upgrade procedure.
Only {0} (or higher) {1} can be upgraded to four-fiber.

You have selected an incorrect ring speed for upgrade. Only rings within the specified parameters can be upgraded to 4-fiber BLSR.

EID-2123

Verify that the following nodes have at least two in-service ports with the same speed as the two-fiber {0}. The ports cannot serve as timing references, and they cannot have DCC terminations or overhead circuits.
{1}

Nonupgradable nodes. Verify that the specified nodes have at least two IS-NR ports with the same speed as the 2-fiber BLSR.
The specified ports cannot serve as a timing reference, and they cannot have data communications channel (DCC) terminations or overhead circuits.

EID-2124

You cannot add this span because it is connected to a node that already has the east and west ports defined.

Refer to the error message text.

EID-2125

You cannot add this span as it would cause a single card to host both the east span and the west span. A card cannot protect itself.

Refer to the error message text.

EID-2126

An error occurred while provisioning the OSPF area.
{0}

There is an Open Shortest Path First (OSPF) area error.

EID-2127

You cannot add this span. It would cause the following circuit(s) to occupy different {0} regions on different spans:
{1}

Either select a different span or delete the above circuit(s).

A circuit cannot occupy different STS regions on different spans. You may add a different span or delete the specified circuit.

EID-2128

The state is invalid.

An internal error occurred while trying to remove a span from a BLSR.

This alarm occurs in the network-level BLSR creation dialog box.

EID-2129

You cannot use same slot for east and west protect ports.

Refer to the error message text.

EID-2130

The ring ID value, {0}, is not valid. Please enter a valid number between 0 and 9999.

Enter a ring ID value between 0 and 9999.

EID-2131

The reversion cannot be set to INCONSISTENT.

You must select another reversion type.

EID-2135

The overhead circuit preferences could not be stored:
{0}

Input/Output error. Unable to store overhead circuit preferences.

EID-2137

An error occurred during the circuit merge.
{0}

There was an error while merging the circuits.

EID-2138

Not all destinations could be deleted.
Please try again.

Refer to the error message text.

EID-2139

An error occurred while updating the destinations.

There was an error in updating the circuit destinations.

EID-2143

No online help version was selected.
The online help book cannot be deleted.

Select the version of online help, and proceed.

EID-2144

An error occurred while deleting the online help book(s).
{0}

You cannot delete the specified online help.

EID-2145

No nodes appear to have a Cisco IOS card.

Refer to error message.

EID-2146

This is a security violation.
You may only logout of your own account.

You cannot logout of an account other than your own.

EID-2147

This is a security violation.
You may only change your own account.

You cannot change an account other than your own.

EID-2148

This is a security violation.
You cannot delete the account under which you are currently logged in.

You cannot delete the account you are currently logged in.

WID-2149

There is no exportable content in this view.

Refer to the error message text.

WID-2150

The node {0} is not initialized.
Please wait and try again.

Wait till the specified node is initialized and try again.

WID-2152

Spanning tree protection is being disabled for this circuit.

Refer to the warning message text.

WID-2153

Adding this drop will make the circuit a PCA circuit.

Refer to the warning message text.

WID-2154

Monitor circuits cannot be created on a port grouping circuit.

Refer to the warning message text.

WID-2155

Switch counts might not be fully supported on some nodes.
{0}

The specified nodes do not support switch counts completely.

WID-2156

The manual roll mode is recommended for dual rolls.
For auto dual rolls, please verify that roll to facilities are in service and error-free.

Refer to the warning message text.

WID-2157

The roll(s) cannot be completed.
{0}

CTC could not complete the roll because the roll is destroyed, in an incomplete state, in a TL1_roll state, is cancelled, or is not ready to complete.

EID-2158

The roll mode is invalid.
{0}

There are two roll modes: auto and manual. For a one-way circuit source roll, the roll mode must be auto and for a one- way circuit destination roll, the roll mode must be manual.

EID-2159

The roll is not ready for completion.
{0}

The roll is not ready for completion.

EID-2160

The roll is not connected.
{0}

Refer to error message text.

EID-2161

The sibling roll is not complete.
{0}

One of the rolls is not completed for the dual roll. If it is auto roll, it will be completed when a valid signal is detected. If it is a manual roll, you must complete the roll from CTC if Bridge and Roll is operated from CTC, or from TL1 if Bridge and Roll is operated from TL1.

EID-2162

An error occurred during roll acknowledgement.
{0}

Refer to the error message text.

EID-2163

The roll cannot be canceled.
{0}

CTC cannot cancel the roll.

EID-2164

An error occurred during the roll.
{0}

CTC encountered a roll error.

WID-2165

The MAC address of the node {0} has been changed. All circuits originating from or dropping at this node will need to be repaired.

Repair the circuits that originate from or drop at the specified node, with the new MAC address.

WID-2166

The node cannot be inserted into the domain because it is not initialized.

Initialize the node and proceed.

WID-2167

You have insufficient security privileges to perform this action.

You do not have the privilege to perform this action.

WID-2168

The following warnings surfaced while loading {0}.
{1}

CTC encountered warnings while loading the alarm profile import file.

WID-2169

One or more of the profiles selected do not exist on one or more of the nodes selected.

The profile selected does not exist on the node. Select another profile.

WID-2170

The profile list on node {0} is full. Please delete one or more profiles if you wish to add the profile.
{1}

The number of profile that can exist on a node has reached the limit. To add a profile, delete any of the existing profiles.

WID-2171

You have been logged out. Click OK to exit CTC.

Refer to the warning message text.

WID-2172

The CTC CORBA (IIOP) listener port setting of {0} will be applied on the next CTC restart.

The Internet Inter-ORB Protocol (IIOP) listener port setting for the CTC Common Object Request Broker Architecture (CORBA) will be applied on the next CTC restart.

EID-2173

The port is unavailable.
The desired CTC CORBA ({0}) listener port, {1}, is already in use or you do not have permission to listen on it. Please select an alternate port.

Select an alternate port, as the current port is either in use or you do not have enough permission on it.

EID-2174

An invalid number was entered. Please check it and try again.

You entered an invalid firewall port number. Try again.

WID-2175

An extension byte mismatch occurred.
{0}

There is a mismatch with the extension byte.

WID-2176

Not all spans have the same OSPF area ID.
This will cause problems with protection switching. To determine the OSPF area for a given span, click on the span and the OSPF area will be displayed in the pane to the left of the network map.

Refer to the warning message text.

WID-2178

Only one edit pane can be opened at a time. The existing pane will be displayed.

Refer to the warning message text.

WID-2179

No update is available because the circuit has been deleted.

Refer to the warning message text.

EID-2180

The CTC initialization failed during step {0}.

CTC initialization has failed in the specified step.

EID-2181

This link cannot be included because it originates from the destination.

You must not include this link as it originates from destination of a circuit. It is against the path selection algorithm.

EID-2182

The value of {0} is invalid.

The value of the specified item is invalid.

EID-2183

The circuit roll failed.
Bridge and roll is not supported on VCAT circuits.

Refer to the error message text.

EID-2184

Spanning Tree Protocol cannot be enabled on some ports because the ports have been assigned an incompatible list of VLANs.
You can view the VLAN/Spanning Tree table or reassign the Ethernet port VLANs.

Refer to the error message text.

EID-2185

The VLANs on some ports cannot be assigned because they are incompatible with the Spanning Tree Protocol.
You can view the VLAN/Spanning Tree table or reassign the VLANs.

Refer to the error message text.

EID-2186

The software download failed on node {0}.

The software could not be downloaded onto the specified node.

EID-2187

The ring name cannot exceed {0} characters.
Please try again.

You must shorten the length of the ring name.

EID-2188

The nodes in this ring do not support alphanumeric IDs. Please use a ring ID between {0} and {1}.

The ring ID should not contain alphanumeric characters, and must be in the specified range.

EID-2189

The TL1 keyword "all" cannot be used as the ring name.
Please provide another name.

Refer to the error message text.

EID-2190

Adding this span will cause the ring to contain more nodes than allowed.

You have reached the maximum number of nodes allowed.

EID-2191

The ring name must not be empty.

You must supply a ring name.

EID-2192

A valid route cannot be found for the circuit creation request.

CTC could not complete the circuit creation request either because there are no physical links, or the bandwidth of the available links are already reserved.

EID-2193

A valid route cannot be found for the circuit drop creation request.

Refer to the error message text.

EID-2194

A valid route cannot be found for the roll creation request.

Refer to the error message text.

EID-2195

The circuit VLAN list cannot be mapped to one spanning tree.
You can view the VLAN/Spanning Tree table or reassign VLANs.

Refer to the error message text.

EID-2196

CTC cannot be relaunched.
{0}

There is an error relaunching CTC.

EID-2197

A CORBA failure occurred. CTC cannot proceed.

There was a CORBA failure, and the task cannot proceed. Verify the Java version.

EID-2198

CTC is unable to switch to the {0} view.

CTC is unable to switch to the specified view.

EID-2199

Login failed on {0} {1}

The login failed on the specified tasks.

EID-2200

CTC has detected a jar file deletion. The jar file was used to manage one or more nodes. This CTC session will not be able to manage those nodes and they will appear gray on the network map. It is recommended that you exit this CTC session and start a new one.

Refer to the error message text.

EID-2202

An intra-node DRI circuit must have two sources.

Intranode circuit must have two sources to be a dual ring interconnect (DRI).

EID-2203

No member was selected.

You must select a member.

EID-2204

The number of circuits must be a positive integer.

The number of circuits cannot be zero or negative.

EID-2205

The circuit type must be selected.

You must select a circuit type.

EID-2206

The profile cannot be autoselected. Please select profile(s) to store and try again.

Refer to the error message text.

EID-2207

You cannot add this span. Either the ring name is too long (that is, ring name length is greater than {0}) or the endpoints do not support alphanumeric IDs.

Reduce the length of the ring name, or remove the alphanumeric characters from the end points.

EID-2208

This is an invalid or unsupported JRE.

The version of Java Runtime Environment (JRE) is either invalid or unsupported.

EID-2209

The user name must be at least {0} characters long.

The user name must be at least of the specified character length.

EID-2210

No package name was selected.

You must select a package name.

EID-2211

No node was selected for upgrade.

You must select a node for the upgrade.

EID-2212

A protected line is not provisionable.

The protected line cannot be provisioned. Choose another line.

WID-2213

The current type or state of some drops does not allow the new circuit state of {0} to be applied to them indirectly.

The circuit state, specified by {0} cannot be applied to the selected drops.

EID-2214

The node is disconnected. Please wait until the node reconnects.

Refer to the error message text.

EID-2215

An error occurred while leaving the {0} page.

There was an error while leaving the specified page.

EID-2216

An error occurred while entering the {0} page.

There was an error while entering the specified page.

EID-2217

Some conditions could not be retrieved from the network view

Refer to the error message text.

EID-2218

The bandwidth must be between {0} and {1} percent.

The bandwidth must be within the specified parameters.

EID-2219

The protection operation failed. An XC loopback was applied on the cross-connection.

As the protection operation failed, a cross-connect (XC) loopback will be applied on cross-connection.

EID-2220

The tunnel status is PARTIAL. CTC is not able to change it.
Please try again later.

Refer to the error message text.

EID-2221

A valid route cannot be found for the unprotected to {0} upgrade request.

Refer to the error message text.

EID-2222

One or more of the following nodes are currently part of a four-fiber {0}. Only a single four-fiber {0} is supported per node.
{1}

The nodes, specified by {1}, are already part of a 4-fiber BLSR/MS-SPRing type (specified by {0}).

EID-2223

Only one circuit can be upgraded at a time.

Refer to the error message text.

EID-2224

This link may not be included because it terminates on the source.

Refer to the error message text.

EID-2225

A valid signal could not be detected while trying to complete the roll.
{0}

Roll can be completed only when a valid signal is detected. If not, the roll completion may result in an error.

EID-2226

The circuit roll failed.
{0}

Refer to the error message text.

EID-2320

This VCAT circuit does not support deletion of its member circuits.

You can not delete a circuit that is a member of VCAT circuit.

EID-2321

An error occurred while deleting member circuits.
{0}

Refer to the error message text.

WID-2322

Not all cross-connects from selected circuits could be merged into the current circuit. They might appear as partial circuits.

Refer to the warning message text.

EID-2323

The circuit roll failed.
Bridge and roll is not supported on monitor circuits.

A monitor circuit does not support Bridge and Roll.

EID-2324

An error occurred during the circuit upgrade.
{0}

Refer to the error message text.

EID-2325

You have failed {0} times to unlock this session. CTC will exit after you click OK or close this dialog box.

The maximum amount of attempts to unlock this session has been reached.

WID-2326

Currently, CTC does not support bridge and roll on circuits that are entirely created by TL1. To continue with bridge and roll in CTC, the selected circuits must be upgraded.
Is it OK to upgrade the selected circuits and continue the bridge and roll operation?

Refer to the warning message text.

WID-2327

Currently, CTC does not support bridge and roll on circuits that are partially created by TL1. To continue with bridge and roll in CTC, the selected circuits must be upgraded.
Is it OK to upgrade the selected circuits and continue the bridge and roll operation?

Refer to the warning message text.

EID-2328

An error occurred during the circuit reconfiguration.
{0}

The attempt to reconfigure the specified circuit has failed.

EID-2329

{0} of {1} circuits could not be successfully created.

A few circuits could not be created.

EID-2330

An error occurred during circuit verification. The selected {0} is invalid!
{1}

The selected item, specified by {0}, is invalid as per the details, specified in {1}.

EID-2331

Deleting {0} might be service affecting.

Deleting the item can affect the service of CTC.

EID-2332

A validation error occurred in row {0}.
{1} hold-off timer for {2} must be between {3}-10,000 ms, in steps of 100 ms.

Refer to the error message text.

EID-3001

An Ethernet RMON threshold with the same parameters already exists. Please change one or more of the parameters and try again.

Change a few parameters in an Ethernet remote monitoring (RMON) threshold and try again.

EID-3002

An error occurred while retrieving defaults from the node: {0}

There was an error while retrieving the defaults from the specified node.

EID-3003

The file {0} cannot be loaded.

CTC cannot load the specified file.

EID-3004

Properties cannot be loaded from the node.

Refer to the error message text.

EID-3005

NE update properties cannot be saved to the file {0}.

CTC cannot save the network element (NE) update values to the specified file.

EID-3006

NE update properties cannot be loaded from the node.

Refer to the error message text.

EID-3007

An error occurred while provisioning the {0}.

There was a provisioning error for the specified item.

EID-3008

This is not a valid card.

You cannot perform DWDM automatic node setup (ANS) from the Card view. Please navigate to the Node view and try again.

EID-3009

No {0} was selected.

Select the specified item, for example, VLAN, port, slot, etc.

EID-3010

A bidirectional optical link could not be created.

Refer to the error message text.

EID-3016

The subnet address is invalid.

Refer to the error message text.

EID-3017

The subnet address already exists.

Refer to the error message text.

EID-3019

The internal subnet address is incomplete.

Enter the complete internal subnet address.

EID-3020

The subnet address cannot be the same for both TSC cards.
The requested action is not allowed.

A node's internal subnet must be different from one another as each TSC is on separate ethernet buses, isolated by broadcast domains.

EID-3021

An error occurred while retrieving the diagnostics:
{0}

Refer to the error message text.

EID-3022

The requested action is not allowed.

The requested action is not allowed.

EID-3023

The low order cross-connect mode could not be retrieved.

Refer to the error message text.

EID-3024

The {0} cross-connect mode could not be switched.
Please verify that the type and/or number of circuits provisioned does not exceed the criterion for switching modes.

CTC cannot switch the cross-connect mode for the specified item, as the type or the number of circuits does not match with the criterion for switching modes.

EID-3025

An error occurred while retrieving thresholds.

There was an error retrieving the thresholds.

EID-3026

The send DoNotUse attribute cannot be modified.

You cannot modify the Send DoNotUse field.

EID-3027

The SyncMsg attribute cannot be modified.

You cannot modify the SyncMsg field.

EID-3028

The port type cannot be changed.

You cannot change the port type.

EID-3029

Unable to switch to the byte because an overhead change is present on this byte of the port.

Refer to the error message text.

EID-3031

An error occurred while hard-resetting the card.

There was an error while resetting card hardware.

EID-3032

An error occurred while resetting the card.

There was an error while resetting the card.

EID-3033

The lamp test is not supported on this shelf.

Refer to the error message text.

EID-3035

The cross-connect diagnostics cannot be performed

Refer to the error message text.

EID-3036

The cross-connect diagnostics test is not supported on this shelf.

The cross-connect diagnostics test is not supported on this shelf.

EID-3039

An error occurred while changing the card type.

There was an error while changing the card.

EID-3040

The card type is invalid.

The selected card type is invalid.

EID-3041

An error occurred while applying changes.

CTC is unable to create a protection group. Check if the protect port supports circuits, a timing reference, SONET SDCC, orderwire, or a test access point.

EID-3042

The flow control low value must be less than the flow control high value for all ports in the card.

Refer to the error message text.

EID-3046

The flow control watermark value must be between {0} and {1}, inclusive.

The flow control watermark value must be between the two specified values.

EID-3047

The file {0} could not be read.
Please verify the name and try again.

Refer to the error message text.

EID-3048

There is no Cisco IOS startup configuration file available to download.

CTC could not find the configuration file for IOS startup.

EID-3049

The download cannot be done at this time because an update in progress.

Refer to the error message text.

EID-3050

An error occurred while trying to save the file to your local file system.

Check whether the file already exists and cannot be over written, or there is a space constraint in the file system.

EID-3051

The configuration file has a maximum size of {0} bytes.

The size of the configuration file should not exceed the specified number of bytes.

EID-3052

An error occurred while saving the configuration file to the TCC2/TCC2P.

Refer to the error message text.

EID-3053

The value of {0} must be between {1} and {2}.

The value of the item must be between the specified values.

EID-3054

The provisioned input/output ports cannot be removed or another user is updating the card. Please try to remove these ports later.

Another user may be updating the card. You can try again later.

EID-3055

The soak maintenance pane cannot be created.

Refer to the error message text.

EID-3056

Defaults cannot be saved to the file {0}.

CTC cannot save the defaults to the specified file.

EID-3057

Default properties cannot be loaded from the node.

Refer to the error message text.

EID-3058

The file {0} does not exist.

Refer to the error message text.

EID-3059

An error occurred while refreshing.

There was an error while refreshing.

EID-3060

The ALS recovery pulse interval must be between {0} seconds and {1} seconds.

The automatic laser shutdown (ALS) Recovery Interval must be between the specified range of seconds.

EID-3061

The ALS recovery pulse duration must be between {0} seconds and {1} seconds.

The automatic laser shutdown (ALS) Recovery Duration must be between the specified range of seconds.

EID-3062

An error occurred while setting values in the table.

Refer to the error message text.

EID-3064

This is not a G1000 card.

This card is not a G1000-4 card.

EID-3065

An error occurred while attempting to create this RMON threshold:
{0}

You must wait some time before you try again.

EID-3066

The sample period must be between 10 and {0}.

Refer to the error message text.

EID-3067

The rising threshold must be between 1 and {0}.

This is an invalid rising threshold entry. The valid range is from 1 to the specified value.

EID-3068

The falling threshold must be between 1 and {0}.

This is an invalid falling threshold entry. The valid range is from 1 to the specified value.

EID-3069

The rising threshold must be greater than or equal to the falling threshold.

Refer to the error message text.

EID-3070

Error in data for ports {0} Exactly one VLAN must be marked untagged for each port. These changes will not be applied.

CTC encountered data error for the specified ports. Only one VLAN should be marked untagged for each port.

EID-3071

An error occurred while retrieving the learned address list.

Unable to retrieve the learned MAC address from the NE.

EID-3072

An error occurred while clearing the learned address.

Failure attempting to clear the learned MAC address from a specific card or Ether group.

EID-3073

An error occurred while clearing the selected rows.

Failure attempting to clear the learned MAC address from a specific card or Ether group.

EID-3074

An error occurred while clearing the learned address list by {0}.

Error encountered trying to clear the learned MAC address from either a VLAN or a port.

EID-3075

At least one row in the parameter column must be selected.

Refer to the error message text.

EID-3076

CTC lost its connection with this node. The NE Setup Wizard will exit.

Refer to the error message text.

EID-3077

No optical link was selected.

Refer to the error message text.

EID-3078

An optical link could not be created.

Refer to the error message text.

EID-3079

Defaults cannot be applied to the node. {0}

CTC cannot apply the defaults to the specified node.

EID-3080

CTC cannot navigate to the target tab.
{0}

CTC cannot go to the specified target tab.

EID-3081

The port type cannot be changed.

Refer to the error message text.

EID-3082

The {0} extension byte cannot be changed.

You cannot modify the specified extension byte.

EID-3084

An error occurred while retrieving laser parameters for {0}.

There is no card, or there was an internal communications error when attempting to get the laser parameters for the card.

EID-3085

No OSC Terminations were selected

Select an OSC termination and proceed.

EID-3086

One or more Osc terminations could not be created.

Refer to the error message text.

EID-3087

The OSC termination could not be edited.

Refer to the error message text.

EID-3088

No {0} card is present to switch.

No card of the specified type is available to switch.

EID-3089

The {0} state cannot be used or changed when the {1} has failed or is missing.

You cannot use or change the specified state when the card is failed or missing.

EID-3090

The operation cannot be performed because the {0} is {1}LOCKED_ON/LOCKED_OUT.

You cannot perform operation.

EID-3091

The operation cannot be performed because the protect card is active.

Refer to the error message text.

EID-3092

The requested action cannot be applied because the service state is invalid.

Select another service state and proceed.

EID-3093

The operation cannot be performed because the duplex pair is {0}locked.

Refer to the error message text.

EID-3094

The operation cannot be performed because no cross-connect redundancy is available.

You cannot perform the requested operation on the cross connect card without having a backup cross connect card.

EID-3095

The deletion failed because the circuit is in use

Refer to the error message text.

WID-3096

An internal communication error was encountered while retrieving laser parameters.
This can happen when equipment is not present or when equipment is resetting.
Check the equipment state and try to refresh the values again.

Refer to the warning message text.

EID-3097

The ring termination is in use.

The ring termination you are trying to access is in use. Try after sometime.

EID-3098

No ring terminations were selected.

Select one of the ring terminations.

EID-3099

The entered key does not match the existing authentication key.

Check the authentication key and reenter.

EID-3100

An error occurred during authentication.

There was an error in authentication. Verify that the key does not exceed the character limit.

EID-3101

The DCC metric must be between 1 and 65535.

The DCC metric should be in the range of 1 to 65535.

EID-3102

The DCC metric is invalid.

There was an invalid DCC metric.

EID-3103

The IP address {0} is invalid}.

The IP address is invalid.

EID-3104

The router priority must be between 0 and 255.

The router priority should be in the range of 0 to 255.

EID-3105

The router priority is invalid.

The router priority is invalid.

EID-3106

The hello interval must be between 1 and 65535.

The hello interval should be in the range of 1 to 65535.

EID-3107

The hello interval is invalid.

The hello interval is invalid.

EID-3109

The dead interval must be between 1 and 2147483647.

The dead interval value must be between 1 and 2147483647.

EID-3110

The dead interval must be larger than the hello interval.

Refer to the error message text.

EID-3111

The LAN transmit delay must be between 1 and 3600 seconds.

The LAN transit delay should be in the range of 1 to 3600 seconds.

EID-3112

The transmit delay is invalid.

The transmit delay is invalid.

EID-3113

The retransmit interval must be between 1 and 3600 seconds.

The retransmit interval should be in the range of 1 to 3600 seconds.

EID-3114

The retransmit interval is invalid.

The retransmit interval is invalid.

EID-3115

The LAN metric must be between 1 and 65535.

The LAN metric should be in the range of 1 to 65535.

EID-3116

The LAN metric is invalid.

The LAN metric is invalid.

EID-3117

If OSPF is active on the LAN, no DCC area IDs may be 0.0.0.0.
Please change all DCC area IDs to non-0.0.0.0 values before enabling OSPF on the LAN.

Refer to the error message text.

EID-3118

If OSPF is active on the LAN, the LAN area ID cannot be the same as the DCC area ID.

LAN must be part of a different OSPF area other than the DCC network.

EID-3119

An error occurred during validation.

CTC was unable to validate the values entered by the user. This error message is common to several different provisioning tabs within CTC (examples include the SNMP provisioning tab, the General> Network provisioning tab, the Security > Configuration provisioning tab, etc.).

EID-3120

No object of type {0} was selected for deletion.

Choose an object of the specified type to delete.

EID-3121

An error occurred while deleting {0}.

There is an error deleting the item.

EID-3122

No object of type {0} was selected to edit.

Choose an object of the specified type to edit.

EID-3123

An error occurred while editing {0}.

There was an error editing the item.

EID-3124

The {0} termination is in use.
Delete the associated OSPF range table entry and try again.

Refer to the error message text.

EID-3125

No {0} terminations were selected.

No specified terminations are selected.

EID-3126

The {0} termination could not be edited.

CTC could not edit the specified termination.

EID-3127

Orderwire cannot be provisioned because the E2 byte is in use by {0}.

Refer to the error message text.

EID-3128

The authentication key cannot exceed {0} characters.

The authentication key cannot exceed the specified number of characters.

EID-3129

The authentication keys do not match!

Refer to the error message text.

EID-3130

An error occurred while creating the OSPF area virtual link.

CTC encountered an error while creating the area virtual link.

EID-3131

An error occurred while creating the OSPF virtual link.

CTC encountered an error creating the virtual link.

EID-3132

An error occurred while setting the OSPF area range: {0}, {1}, false.

CTC encountered an error while setting the area range for the specified values.

EID-3133

The maximum number of OSPF area ranges has been exceeded.

OSPF area ranges exceeded the maximum number.

EID-3134

The area ID is invalid. Use the DCC OSPF area ID, LAN port area ID, or 0.0.0.0.

Refer to the error message text.

EID-3135

The mask is invalid.

Refer to the error message text.

EID-3136

The range address is invalid.

The range address is invalid. Try again.

EID-3137

Your request has been denied because the timing source information was updated while your changes were still pending. Please retry.

Refer to the error message text.

EID-3138

The clock source for switching is invalid.

You have selected an invalid clock source. Choose another clock.

EID-3139

A switch cannot be made to a reference of inferior quality.

Refer to the error message text.

EID-3140

A higher priority switch is already active.

You cannot switch the timing source manually when a higher priority switch is already active.

EID-3141

An attempt was made to access a bad reference.

Refer to the error message text.

EID-3142

No switch is active.

None of the switches are active.

EID-3143

An error occurred while creating the static route entry.

CTC encountered an error while a creating static route entry.

EID-3144

The maximum number of static routes has been exceeded.

The number of static routes has exceeded its limit.

EID-3145

The RIP metric must be between 1 and 15.

The Routing Information Protocol (RIP) metric should be in the range of 1 to 15.

EID-3146

The RIP metric is invalid.

Refer to the error message text.

EID-3147

An error occurred while creating the summary address.

There was an error while creating the summary address.

EID-3148

No Layer 2 domain has been provisioned.

You must provision any one of the layer 2 domain.

EID-3149

The MAC addresses could not be retrieved.

Refer to the error message text.

EID-3150

The target file {0} is not a normal file.

The specified target file is not a normal file.

EID-3151

The target file {0} is not writable.

The target file is not writeable. Specify another file.

EID-3152

An error occurred while creating the protection group.

CTC encountered an error creating Protection Group.

EID-3153

The card cannot be deleted because it is in use.

Refer to the error message text.

EID-3154

An error occurred while provisioning the card:
CTC cannot {0} the card.

CTC cannot perform the task on the card.

EID-3155

An error occurred while building the menu.

CTC encountered an error building the menu.

EID-3156

An error occurred while building the menu.
Cards were not found for the {0} group.

CTC encountered an error while building the menu, as cards could not be found for the specified group).

EID-3157

The selected model could not be set because of an unexpected model class: {0}.

CTC encountered an unexpected model class while trying to complete the task.

EID-3158

Probable causes:
- Unable to switch, because a similar or higher priority condition exists on a peer or far-end card.
- A loopback is present on the working port.

Refer to the error message text.

EID-31591

An error occurred while applying the operation.

CTC encountered an error while applying this operation.

EID-3160

An error occurred while provisioning the {0}.

CTC encountered the specified error.

EID-3161

An error occurred while upgrading the ring.

An error was encountered while attempting to upgrade the BLSR. Refer to the details portion of the error dialog box for more information.

EID-3162

This protection operation cannot be set because the protection operation on the other side has been changed but not yet applied.

Refer to the error message text.

EID-3163

The data in row {0} cannot be validated.

CTC cannot validate the data for the specified row.

EID-3164

The new node ID ({0}) for ring ID {1} duplicates the ID of node {2}.

The new specified node ID for the specified ring ID is the same as another node ID.

EID-3165

The ring ID provided is already in use. Ring IDs must be unique.

Refer to the error message text.

EID-3166

An error occurred while refreshing the {0} table.

CTC encountered an error while refreshing the specified table.

EID-3167

The slot is already in use.

Refer to the error message text.

EID-3168

An error occurred while provisioning.

An error was encountered while attempting the specified provisioning operation. Refer to the details portion of the error dialog box for more information.

EID-3169

An error occurred while adding the card.

CTC encountered an error while adding the card.

EID-3170

You cannot delete this card: {0}.

Refer to the error message text.

EID-3171

An error occurred while creating the trap destination.

CTC encountered an error creating the trap destination.

EID-3172

No RMON thresholds were selected.

Select an RMON threshold.

EID-3173

The contact ''{0}'' cannot exceed {1} characters.

The specified contact exceeds the specified character limit.

EID-3174

The description ''{0}'' cannot exceed {1} characters.

The specified location exceeds the specified character limit.

EID-3175

The operator identifier ''{0}'' cannot exceed {1} characters.

The specified operator identifier exceeds the specified character limit.

EID-3176

The operator specific information ''{0}'' cannot exceed {1} characters.

The specified operator specific information exceeds the specified character limit.

EID-3177

The node name cannot be empty.

The specified name is empty.

EID-3178

The node name ''{0}'' cannot exceed {1} characters.

The specified name exceeds the specified character limit.

EID-3179

The protect card is in use.

Refer to the error message text.

EID-3180

The 1+1 protection group does not exist.

Create a 1+1 protection group.

EID-3181

The Y-cable protection group does not exist.

Refer to the error message text.

EID-3182

The topology element is in use and cannot be deleted as requested.

You cannot delete the topology element which is in use.

EID-3183

An error occurred while deleting the protection group.

CTC encountered an error while deleting the protection group.

EID-3184

No {0} was selected.

You must select an item before completing this task.

EID-3185

This ring has an active protection switch operation and cannot be deleted at this time.

Refer to the error message text.

EID-3186

The node is busy: {0} is {1} and cannot be deleted as requested.

The request cannot be completed.

EID-3187

An error occurred while deleting the trap destination.

CTC encountered an error deleting the trap destination.

EID-3188

An error occurred during authentication. The password entered is invalid.

The password you entered is invalid. Enter the password again.

EID-3189

The sum of the {0} must be between {1} and {2}.

Refer to the error message text.

EID-3214

The number of high order circuits for the line could not be retrieved.

The number of High Orders (STS/STM) for the line is not available.

EID-3215

An error occurred while refreshing.

Used frequently in pane classes to indicate a general error condition when trying to refresh from the model.

EID-3216

The proxy port is invalid.

Refer to the error message text.

EID-3217

The statistics could not be refreshed.

CTC could not refresh statistics values.

EID-3218

The automatic node setup could not be launched.

Refer to the error message text.

EID-3219

The automatic node setup information could not be refreshed.

Failure trying to retrieve automatic node setup information.

EID-3220

An error occurred while refreshing row {0}.

Error refreshing the specified row.

EID-3222

The statistics could not be cleared.

Refer to the error message text.

EID-3225

An error occurred while refreshing the pane.

Used frequently in pane classes to indicate a general error condition when trying to refresh from the model.

EID-3226

The {0} termination(s) could not be deleted.
{1}

Refer to the error message text.

EID-3227

A baseline could not be recorded. Performance metrics will remain unchanged.

CTC failed to set the baseline values while provisioning NE. Previous values remain unchanged.

EID-3228

The {0} termination(s) could not be created.
{1}

Refer to the error message text.

EID-3229

RIP is active on the LAN. Please disable RIP before enabling OSPF.

Turn off the Routing Information Protocol (RIP) on the LAN, before enabling OSPF.

EID-3230

OSPF is active on the LAN. Please disable OSPF before enabling RIP.

Turn off the OSPF on the LAN before enabling RIP.

EID-3231

An error occurred while setting the OPR.

An error was encountered while attempting to provision the optical power received (OPR).

WID-3232

The port state cannot be indirectly transitioned because the port is still providing services.
If the port state should be changed, edit it directly through port provisioning.

Edit the port state while provisioning the port.

EID-3233

The current loopback provisioning does not allow this state transition.

Refer to the error message text.

EID-3234

The current synchronization provisioning does not allow this state transition.

You cannot transition the port state to the target date while in the current synchronization state.

EID-3235

The requested state transition cannot be performed on this software version.

Refer to the error message text.

EID-3236

The database restore failed. {0}

CTC failed to restore the specified database.

EID-3237

The database backup failed. {0}

CTC failed to backup the specified database.

EID-3238

The send PDIP setting on {0} is inconsistent with the setting on the control node {1}.

The send payload defect indicator path (PDI-P) setting on the specified item should be consistent with that of the specified control node.

EID-3239

The overhead termination is invalid

Refer to the error message text.

EID-3240

The maximum number of overhead terminations has been exceeded.

Overhead terminations have exceeded the limit.

EID-3241

The {0} termination port is in use.

The specified termination port is in use. Select another port.

EID-3242

An {1} exists on the selected ports.
Therefore, you must create the {0}s one by one.

The specified DCC already exists on the selected port. You can create a DCC of another type.

WID-3243

The port you have chosen as an {0} endpoint already supports an {1}. The port cannot support both DCCs. After the {0} is created, verify that no EOC alarms are present and then delete the {1} to complete the downgrade.

The same port can not be used by multiple DCCs.

EID-3244

An {0} exists on the selected ports.
Therefore, you must create the {1}s one by one.

The specified DCC already exists on the selected port. You can create a DCC of another type.

WID-3245

The port you have chosen as an {1} endpoint already supports an {0}. The port cannot support both DCCs. After the {1} is created, verify that no EOC alarms are present and then delete the {0} to complete the upgrade.

The port selected as a DCC endpoint already supports another DCC. Refer to the warning message text.

EID-3246

The wizard was not able to validate the data.
{0}

CTC encountered an error.

EID-3247

An ordering error occurred. The absolute value should be {0}.

The absolute value entered was wrong.

EID-3248

The value for the parameter {0} is invalid.

CTC changed the incorrect parameter.

EID-3249

The voltage increment value is invalid.

Refer to the error message text.

EID-3250

The power monitor range is invalid.

Refer to the error message text.

EID-3251

The requested action could not be completed.
{0}

CTC could not complete the specified action.

EID-3252

No download has been initiated from this CTC session.

Refer to the error message text.

EID-3253

The reboot operation failed. {0}

Refer to the error message text.

EID-3254

An error occurred during validation. {0}

The Cisco Transport Controller (CTC) was unable to validate the values entered by the user, specified by {0}. This error message is common to several different provisioning tabs within the CTC.

EID-3255

You cannot change the timing configuration because a Manual/Force operation is in effect.

Refer to the error message text.

WID-3256

The timing reference(s) could not be assigned because one or more of the timing reference(s):
- is already used and/or
- has been selected twice and/or
- is attempting to use the same slot twice.
Please verify the settings.

Refer to the warning message text.

EID-3257

Duplicate DCC numbers are not permitted. {0}.

CTC detected more than one occurrence of the a DCC number. Remove one of them.

EID-3258

A software error occurred while attempting to download the file.
Please try again later.

Refer to the error message text.

EID-3259

An error occurred while creating the FC-MR threshold.

You must create a Fibre Channel Multirate (FC_MR) card threshold.

EID-3260

An error occurred while provisioning the internal subnet:
{0}

The specified internal subnet could not be provisioned.

EID-3261

The port rate provisioning cannot be changed while circuits exist on this port.

Refer to the error message text.

EID-3262

The port provisioning cannot be changed when the port status is {0}.

You must provision the ports only when the port is Out of Service.

WID-3263

You are using Java version {0}. CTC should run with Java version {1}. It can be obtained from the installation CD or http://java.sun.com/j2se/

CTC is being launched with the wrong version of the JRE {0}. This version of CTC requires a particular version of the JRE {1}. The CTC and browser must be closed and restarted to allow the correct Java version to be loaded.

EID-3265

An error occurred while modifying the protection group.

Protection Group could not be modified.

EID-3266

Conditions could not be retrieved from the shelf or card view.

Refer to the error message text.

WID-3267

The XTC protection group cannot be modified.

Refer to the warning message text.

WID-3268

The filter entry is invalid. {0}

The specified entry is invalid.

WID-3269

The {0} operation was successfully initiated for {1} but its completion status could not be obtained from the node. When the node is accessible, check its software version to verify if the {0} succeeded.

Refer to the error message text.

WID-3270

The file {0} does not exist.

The specified file does not exist.

WID-3271

The value entered must be greater than {0}.

The value entered must be greater than the specified value.

WID-3272

An entry is required.

An entry is required to complete this task.

WID-3273

{0} already exists in the list.

The specified item already exists in the list.

WID-3274

A software upgrade is in progress.
Network configuration changes that result in a node reboot cannot take place during a software upgrade.
Please try again after the software upgrade is done.

Refer to the warning message text.

WID-3275

Ensure that the remote interface ID and the local interface ID on the two sides match.
(The local interface ID on this node should equal the remote interface ID on the neighbor node and vice-versa).

Refer to the warning message text.

WID-3276

Both {0} and {1} exist on the same selected port.
{2}

The specified port has both SDCC and LDCC.

WID-3277

The description cannot exceed {0} characters. Your input will be truncated.

The input exceeds the character limit. The value will be truncated to the maximum chapter limit.

WID-3279

This card has been deleted. CTC will return to the shelf view.

CTC returns to node view.

WID-3280

ALS will not engage until both the protected trunk ports detect LOS.

Refer to the warning message text.

WID-3282

Performing a software upgrade while TSC 5 is active could result in a service disruption. It is recommended that you make TSC 10 the active TSC by performing a soft reset of TSC 5. The following ONS 15600s are currently unsafe to upgrade...

Refer to the warning message text.

WID-3283

Before activating a new version, ensure that you have a database backup from the current version.

Refer to the warning message text.

WID-3284

Reverting to an older version.

CTC is being reverted to an older version of application.

WID-3285

Applying FORCE or LOCKOUT operations might result in traffic loss.

Refer to the warning message text.

WID-3286

The ring status is INCOMPLETE. CTC cannot determine if there are existing protection operations or switches in other parts of the ring. Applying a protection operation at this time could cause a traffic outage. Please confirm that no other protection operations or switches exist before continuing.

Refer to the warning message text.

WID-3287

There is a protection operation or protection switch present on the ring. Applying this protection operation now will probably cause a traffic outage.

Refer to the warning message text.

WID-3288

The status of this ring is INCOMPLETE. CTC will not be able to apply this change to all of the nodes in the {0}.

Change the ring status to apply the change to all nodes in the ring type.

EID-3290

The specified provisionable patchcord(s) could not be deleted.

Refer to the error message text.

EID-3291

The revertive behavior cannot be changed because a protection switch is active.

Protection switch should not be active to change the revertive behavior.

EID-3292

An error occurred while resetting the shelf.

CTC encountered an error while resetting the node.

EID-3293

No such provisionable patchcords exists.

You are attempting to delete a provisionable patchcord that does not exist. This happens when multiple instances of CTC are running and attempting to delete the same provisionable patchcord concurrently.

EID-3294

No RMON thresholds are available for the selected port.

Refer to the error message text.

EID-3295

This card does not support RMON thresholds.

Refer to the error message text.

EID-3296

Buffer-to-buffer credit is only supported for Fibre Channel (FC) and FICON.

Refer to the error message text.

EID-3298

This interfaces does not support ALS auto restart.

Refer to the error message text.

EID-3300

Duplicate OSPF area IDs are not permitted.

OSPF area IDs should be unique.

EID-3301

The LAN metric cannot be zero.

Refer to the error message text.

EID-3302

The standby {0} is not ready.

Standby controller card is not ready.

EID-3303

The DCC area ID and {0} conflict.
{1}

DCC Area ID and ring type, specified by {0}, conflict each other due to the details specified by {1}.

EID-3304

The DCC number is out of range.

Enter a DCC number that is within the range

EID-3305

OSPF cannot be active on the LAN interface when the backbone area is set on a DCC interface.

You cannot have the default OSPF area on a DCC while OSPF is enabled on the LAN.

EID-3306

Ethernet circuits must be bidirectional.

Refer to the error message text.

EID-3307

An error occurred while creating a connection object at {0}.

CTC encountered an error at the specified connection while creating the connection.

EID-3308

DWDM links can be used only for optical channel circuits.

Refer to the error message text.

EID-3309

The link was excluded because it was in the wrong direction.

The optical channel (circuit) does not allow the specified link to be included because it is in the wrong optical direction.

EID-3310

The DWDM link does not have wavelengths available.

Refer to the error message text.

EID-3311

The laser is already on.

Refer to the error message text.

EID-3312

The power setpoint cannot be changed.
{0} {1}

CTC cannot change the power setpoint. The new setpoint would either make the thresholds inconsistent or set the fail threshold outside the range.

EID-3313

The offset cannot be modified because the service state of the port is IS.

Refer to the error message text.

EID-3314

The requested action is not allowed.
The state value is invalid.

Refer to the error message text.

EID-3315

This operation cannot be performed.

CTC is unable to perform operation.

EID-3316

The node side is invalid.

This task was applied to the wrong node side.

EID-3317

The ring name is too long.

Reduce the number of characters in the name.

EID-3318

The ring name is invalid.

The name you entered is illegal.

EID-3319

The wrong line was selected.

Select another line

EID-3320

The optical link could not be deleted.

CTC cannot delete the optical link.

EID-3321

This feature is unsupported by this version of software.

Refer to the error message text.

EID-3322

The equipment is not plugged in.

Plug-in the equipment and proceed.

EID-3323

The APC system is busy.

Automatic Power Control (APC) system is busy.

EID-3324

There is no path to regulate.

There is no circuit path to regulate.

EID-3325

The requested action is not allowed.

Generic DWDM provisioning failure message.

EID-3326

The input was invalid.

The input value is incorrect.

EID-3327

An error occurred while retrieving thresholds.

There was an error retrieving the thresholds. This message is displayed only for the OSCM/OSC-CSM line thresholds.

EID-3328

An error occurred while applying changes to row {0}.
The value is out of range.

There was an error applying the changes to the specified row. The value is out of range.

EID-3330

Unable to switch to the byte because an overhead channel is present on this byte of the port.

Refer to the error message text.

EID-3331

An error occurred while applying changes to the row.

Refer to the error message text.

EID-3334

Timing parameters on the protect port cannot be changed.

You cannot change timing parameters on protect port.

EID-3335

The port type cannot be changed because the SDH validation check failed. Check if this port is part of a circuit, protection group, SONET DCC, orderwire, or UNI-C interface.

Refer to the error message text.

EID-3336

An error occurred while reading a control mode value.

The Control Mode must be retrieved.

EID-3337

An error occurred while setting a set point gain value.

The Gain Set Point must be set.

EID-3338

An error occurred while reading a set-point gain value.

The Gain Set Point must be retrieved.

EID-3339

An error occurred while setting a tilt calibration value.

The tilt calibration must be set.

EID-3340

An error occurred while setting expected wavelength.

The expected wavelength must be set.

EID-3341

An error occurred while reading expected wavelength.

The expected wavelength must be retrieved.

EID-3342

An error occurred while reading actual wavelength.

The actual wavelength must be retrieved.

EID-3343

An error occurred while reading actual band.

The actual band must be retrieved.

EID-3344

An error occurred while reading expected band.

The expected band must be retrieved.

EID-3345

An error occurred while setting expected band.

The expected band must be set.

EID-3346

An error occurred while retrieving defaults from the node: {0}.

There was an error retrieving defaults from the specified node.

EID-3347

The file {0} cannot be loaded.

CTC cannot load the specified file.

EID-3348

Properties cannot be loaded from the node.

Refer to the error message text.

EID-3349

NE update properties cannot be saved to a file.

Check your file system for space constraint or any other problem.

EID-3350

NE update properties cannot be loaded from the node.

Refer to the error message text.

EID-3351

The file {0} does not exist.

The specified file does not exist.

EID-3352

An error occurred while setting a value at {0}.

There was an error while setting the value at the specified location.

EID-3353

No such interface is available.

The interface specified is not present in CTC.

EID-3354

The specified endpoint is in use.

Select another endpoint that is not in use.

EID-3355

The specified endpoint is incompatible.

Refer to the error message text.

EID-3357

The connections could not be calculated.

Refer to the error message text.

EID-3358

An optical link model does not exist for the specified interface.

Create an optical linkmodel for the interface, and proceed.

EID-3359

Optical parameters could not be set for the node.

Refer to the error message text.

EID-3360

ANS cannot be performed.
Please check {0} parameter value.

Refer to the error message text.

EID-3361

The ring termination is in use.
An error occurred while deleting the ring termination.

You cannot delete a ring in use.

EID-3362

An error occurred while deleting the ring termination.

There was an error while deleting ring termination.

EID-3363

No ring terminations were selected.

You must select a ring termination.

EID-3364

An error occurred while creating the ring ID.

There was an error while creating the ring ID.

EID-3365

The OSC termination is in use.

Select another optical service channel (OSC) which is not in use.

EID-3366

The OSC termination could not be deleted.

There was an error deleting the OSC termination.

EID-3370

No optical link was selected.

You must select an optical link.

EID-3371

An error occurred while calculating the automatic optical link list.

Refer to the error message text.

EID-3372

CTC attempted to access an OCHNC connection that has been destroyed.

CTC destroyed an external attempt to access an optical channel network connection.

EID-3375

The expected span loss must be set.

Refer to the error message text.

EID-3376

The measured span loss could not be retrieved.

Refer to the error message text.

EID-3377

The wrong interface was used.

The interface used for the card is wrong.

EID-3378

This is a duplicate origination patchcord identifier.

The provisionable patchcord identifier to the patchcord you are attempting to provision is already in use by another patchcord on the origination node.

EID-3379

This is a duplicate termination patchcord identifier.

The provisionable patchcord identifier to the patchcord you are attempting to provision is already in use by another patchcord on the remote node.

EID-3380

The host cannot be found.

Refer to the error message text.

EID-3381

The maximum frame size must be between {0} and {1} and may be increased in increments of {2}.

The frame size must be in the specified range. It can increment by the specified value.

EID-3382

The number of credits must be between {0} and {1}.

The number of credits must be between the specified values.

EID-3383

The GFP buffers available must be between {0} and {1} and may be increased in increments of {2}.

The GFP buffers must be in the specified range. It can increment by the specified value.

WID-3384

You are about to force the use of Secure Mode for this chassis. You will not be able to undo this operation.
Is it OK to continue?

Refer to the warning message text.

EID-3385

{0}. Delete the circuits and try again.

Refer to the error message text.

EID-3386

The transponder mode could not be provisioned:
{0}

The specified transponder mode cannot be provisioned.

EID-3387

You must change port(s) {0} to an out-of-service state before changing card parameters. Click "Reset" to revert the changes.

All the card ports should be changed to out-of-service before changing the parameters.

EID-3388

The card mode cannot be changed because the card has circuits.

Refer to the error message text.

EID-3389

An error occurred while changing the card mode.

Refer to the error message text.

EID-3390

The port is in use.

Refer to the error message text.

EID-3391

The port rate cannot be changed because the port has been deleted.

You cannot change the port rate of a card that has been deleted.

WID-3392

The timing reference(s) could not be assigned because with external timing, only a single protected, or two unprotected timing references per BITS Out can be selected.
Please use the "Reset" button and verify the settings.

Refer to the warning message text.

WID-3393

The timing reference(s) could not be assigned because with line or mixed timing, only a single unprotected timing reference per BITS Out can be selected.
Please use the "Reset" button and verify the settings.

Refer to the warning message text.

EID-3394

An error occurred while refreshing the power monitoring values.

Refer to the error message text.

EID-3395

The configuration is invalid.
{0}

CTC encountered an error in IP address, net mask length, or default router, or a restricted IIOP port was selected.

EID-3396

The configuration is invalid. The standby controller card is not a TCC2P card.

The standby controller card should be a TCC2P card.

EID-3397

The file {0} is the wrong version.

The specified file is of wrong version.

EID-3398

The PPM cannot be deleted.

Refer to the error message text.

EID-3399

The PPM cannot be deleted because it has port(s) in use.

Remove the ports connected to the Pluggable Port Module before it can be deleted.

EID-3400

Unable to switch. A force to the primary facility is not allowed.

Refer to the error message text.

EID-3401

{0} cannot be provisioned for the port while {1} is enabled.

The relationship between parameters {0} and {1} are such that enabling either one, prevents the provisioning of the other.

EID-3402

The switch request could not be completed.
The {0} card is not present or is not responding.
Try again after ensuring that the {0} card is present and is not resetting.

Refer to the error message text.

EID-3403

The administrative state transition has not been attempted on the monitored port.

Refer to the error message text.

EID-3404

The far end IP address could not be set on the {0} termination. The IP address cannot be:
loopback (127.0.0.0/8)

class D (224.0.0.0/4)

class E (240.0.0.0/4)

broadcast (255.255.255.255/32)

internal {1}

Refer to the error message text.

EID-3405

You cannot change card parameters with port {0} in {1} state. Click "Reset" to revert the changes.

Refer to the error message text.

EID-4000

The {0} ring name cannot be changed now because a {0} switch is active.

You cannot change the ring name because a switch of the same ring type is active.

EID-4001

The {0} node ID cannot be changed now because a {0} switch is active.

You cannot change the ring ID because a switch of the same ring type is active.

WID-4002

CAUTION: Reverting to an earlier software release may result in TRAFFIC LOSS and loss of connectivity to the node. It may require onsite provisioning to recover.
If the node was running {0} before, reverting will restore the {0} provisioning, losing any later provisioning. If the node was running some other version, reverting will LOSE ALL PROVISIONING.
{1}
{2}

Refer to the warning message text.

EID-4003

The Cisco IOS console is disabled for the card in Slot {0}.

The card may not be an IOS-based card or it may be rebooting.

EID-4004

An error occurred while canceling the software upgrade.

CTC encountered an error while cancelling the software upgrade.

EID-4005

{0} encountered while performing a database backup.

CTC encountered the specified error during database backup.

EID-4006

The file {0} does not exist or cannot be read.

Refer to error message.

EID-4007

The size of the file {0} is zero.

The size of the file that is being backed up or restored is zero.

WID-4008

A software upgrade is in progress.
{0} cannot proceed during a software upgrade.
Please try again after the software upgrade has completed.

The specified action cannot be performed during a software upgrade. You must try after the upgrade process is completed.

EID-4009

{0} encountered while restoring the database.

CTC encountered the specified error while restoring the database.

EID-4010

The operation was terminated because:
{0}

Refer to the error message text.

EID-4011

An error occurred during provisioning:
{0}

Refer to the error message text.

EID-5000

A valid route cannot be found for the tunnel change request.

Refer to the error message text.

EID-5001

The tunnel could not be changed.

Refer to the error message text.

EID-5002

The tunnel could not be restored and must be recreated manually.

Refer to the error message text.

EID-5003

The circuit roll failed.
{0}

Refer to the error message text.

EID-5004

There is already one four-fiber {0} provisioned on the set of nodes involved in {1}. The maximum number of four-fiber {0} rings has been reached for that node.

There is already one 4F BLSR provisioned on the set of nodes involved in the ring. The maximum number of 4F BLSR rings has been reached for that node.

WID-5005

A non-zero hold-off time can violate switching time standards, and should only be used for a circuit with multiple path selectors.

Refer to the warning message text.

WID-5006

Warning: A different secondary {0} node should only be used for DRI or open-ended path protected circuits.

You should use different secondary end point only for DRI or open-ended path protected circuits.

WID-5007

If you change the scope of this view, the contents of this profile editor will be lost.

Refer to the warning message text.

WID-5008

Please ensure that all the protection groups are in proper states after the cancellation.

Refer to the warning message text.

WID-5009

The circuit {0} is not upgradable.
No {1} capable {2}s are available at the node {3}.

No VT capable STSs are available at the node.

EID-5010

The domain name already exists.

Refer to the error message text.

EID-5011

The domain name cannot exceed {0} characters.

You may have reached the maximum number of characters.

WID-5012

The software load on {0} does not support the addition of a node to a 1+1 protection group.

Refer to the warning message text.

EID-5013

{0} does not support the bridge and roll feature. Please select a different port.

The specified port does not support Bridge and Roll.

EID-5014

An automatic network layout is already in progress.
Please wait for it to complete before running it again.

You must for the automatic network layout to complete before running it again.

WID-5015

{0} cannot be applied to {1}.

You cannot apply the admin state operation, specified by {0}, to port count, specified by {1}.

EID-5016

An error occurred while attempting to provision the {0}.
{1}

CTC encountered an error while provisioning the card.

EID-5017

Provisioning could not be rolled back. The {0} might be left in an INCOMPLETE state and should be manually removed.

You may have to remove the BLSR manually as it was left incomplete.

EID-5018

{0} is a(n) {1} node and cannot be added to a(n) {2} network.

You cannot add the node {0} of type {1} to the host node of type {2}. This prevents you from hosting both SONET and SDH nodes in the same session.

EID-5019

The manual path trace mode for this equipment does not support an expected string consisting of all null characters.
Please change the expected string or the path trace mode.

The path trace mode does not support strings that consist of null characters. You must either change the expected string or the path trace mode.

EID-5020

Software activation is in progress. Provisioning is not allowed.

Refer to the warning message text.

EID-5021

Software activation is in progress. {0} is not allowed.

Refer to the error message text.

WID-5022

Warning: Ethergroup circuits are stateless (that is, always in service).
The current state selection of {0} will be ignored.

Refer to the warning message text.

EID-5023

CTC cannot communicate with the node.
The operation failed.

CTC encountered a network communication error. Connectivity between CTC and the NE was disrupted, either transiently or permanently.

EID-5024

The overhead circuit will not be upgraded.

Refer to the error message text.

WID-5025

The path targeted for this switch request is already active. The switch request can be applied, but traffic will not switch at this time.

Refer to the warning message text.

EID-5026

An ONS 15600 cannot serve as the primary or secondary node in a four-fiber {0} circuit. Please change your ring and/or node selections so that an ONS 15600 is not chosen as the primary or secondary node in this four-fiber {1} circuit.

Refer to the error message text.

WID-5027

The {0} Edit dialog box for the ring {1} has been closed due to significant provisioning changes. These changes might only be transitory, so you can reopen the {0} Edit dialog box to view the updated state.

Re-open the BLSR/MS-SPRing edit window to view the updated state of the ring.

WID-5028

Warning: This operation should only be used to clean up rolls that are stuck. It might also affect completeness of the circuit.
Is it OK to continue with the deletion?

Refer to the warning message text.

EID-5029

A software downgrade cannot be performed to the selected version while an SSXC card is inserted in this shelf. Please follow the steps to replace the SSXC with a CXC card before continuing the software downgrade.

Refer to the error message text.

EID-5030

A software downgrade cannot be performed at the present time.

Try the software downgrade later.

WID-5031

Canceling a software upgrade during a standby TSC clock acquisition might result in a traffic outage.

Refer to the warning message text.

EID-5032

An error occurred while accepting the load.

Refer to the error message text.

EID-5033

The profile could not be loaded.
An error occurred while decoding the characters.

CTC detected an error while decoding characters and could not load the profile.

EID-5034

The profile could not be loaded.

An error occurred while trying to recognize the file format.

CTC detected an error and could not load the profile.

EID-5035

The profile could not be loaded.
An error occurred while reading the file.

CTC could not read the file and is therefore unable to load the profile.

EID-5036

The GNE hostname {0} is invalid.

The specified host name is invalid. CTC could not resolve the host name to any valid IP address

EID-5037

Provisionable patchcords cannot be created between transponder trunk ports and multiplexer/demultiplexer ports on the same node.

You must create provisionable patchcords between transponder trunk ports and mux/demux ports that are on different nodes.

EID-5038

Provisionable patchcords created between transponder trunk ports and multiplexer/demultiplexer ports must use the same wavelength:
{0} is not equal to {1}.

Wavelengths used by provisionable patchcords for transponder trunk ports and mux/demux ports must be the same.

EID-5039

Provisionable patchcords created between transponder trunk ports and multiplexer/demultiplexer ports must use the same wavelength:
{0} is not equal to {1}.
Please provision the {2} wavelength on {3}.

Transmitter and receiver port wavelengths are not equal. Provision the receiver and transmitter wavelengths on transmitter and receiver ports respectively.

EID-5040

Provisionable patchcords created between OC3/OC12 ports and multiplexer/demultiplexer ports are not supported.

Refer to the error message text.

EID-5041

Provisionable patchcords created between gray OC-N trunk ports and multiplexer/demultiplexer ports are not supported.

Refer to the error message text.

EID-5042

Provisionable patchcords created between OC-N trunk ports and multiplexer/demultiplexer ports must use the same wavelength:
{0} is not equal to {1}.

Wavelengths used by provisionable patchcords for OC-N trunk ports and mux/demux ports must be the same.

WID-5043

Warning: Only the line card was provisioned.
The wavelength compatibility check was skipped.

Refer to the warning message text.

EID-5044

Virtual links can be used only for OCH-Trail circuits.

Refer to the error message text.

EID-5045

The virtual link does not have wavelengths available.

Set wavelengths for the virtual link and proceed.

WID-5046

Warning: if you select "Use OCHNC Direction," your circuit will be limited to nodes prior to release 07.00.

Refer to the warning message text.

EID-5047

Provisionable patchcords created between OC3/OC12 ports are not supported.

Refer to the error message text.

EID-5048

Provisionable patchcords created between gray OC-N trunk ports are not supported.

Refer to the error message text.

EID-5049

Provisionable patchcords created between gray OC-N trunk ports and multiplexer/demultiplexer ports are not supported.

Refer to the error message text.

EID-5050

The element model could not be found.
{0}

The specified Element Model cannot be located.

WID-5051

The port state cannot be indirectly transitioned because the port aggregates OCHCC circuits: if the port state needs to be changed, edit it directly through port provisioning.

Refer to the warning message text.

EID-5052

The operation is not valid for the connection type.

You may have selected the incorrect switch.

EID-5053

The operation cannot be performed because the connection is under test access.

Refer to the error message text.

EID-5054

The TL1 tunnel could not be opened. {0}

Refer to the error message text.

EID-5055

Some patchcords were not deleted. Patchcords cannot be deleted if they are incomplete or support any circuits, or if the nodes supporting them are not connected.

Refer to the error message text.

EID-5056

This PPC cannot be deleted because one or more circuits are provisioned over it.

Remove the circuits provisioned over the provisionable patchcord before trying to delete it.

EID-5057

The addition of the last node has not yet finished.
Please wait before trying to add a new node.

Refer to the error message text.

EID-5058

An OCHNC upgrade is applicable only to bidirectional circuits.

Refer to the error message text.

EID-5059

The OCHNC upgrade failed.
One or more communication failures occurred during the operation.

CTC encountered a complete failure while upgrading optical channel network connection.

EID-5060

The OCHNC upgrade partially failed.
One or more communication failures occurred during the operation.
Create the OCHCC manually.

CTC encountered a partial failure while upgrading an optical channel network connection.

EID-5061

The overhead circuit source and destination must reside on the same shelf.

Refer to the error message text.

EID-5062

A four-fiber {0} cannot be created using three cards.

A four-fiber BLSR needs four cards.

WID-5063

The profile "{0}" includes a change to the OPEN-SLOT alarm severity.
This change is disallowed for the ONS 15600. "{1}" will continue to use the OPEN-SLOT severity of MN that is included in the default configuration.
Other changes from the "{2}" profile were successfully applied to {3}".

Refer to the warning message text.

EID-5064

{0}

{1}

This indicates the status of path protection switching.

WID-5065

If you apply routing constraints to more than {0} nodes, performance might be affected and the operation might require more time than expected.
Select Yes if you intend to proceed in spite of this risk, or No if you prefer to review your selection.

Refer to the warning message text.

WID-5066

The routing constraints will be lost.
Are you sure you want to reset your changes?

Refer to the warning message text.

WID-5067

The routing constraints will be lost.
Are you sure you want to leave this panel?

Refer to the warning message text.

EID-5068

The routing constraints could not be applied.

Refer to the error message text.

EID-5069

A source node cannot be added to either of these lists.

Select a node other than the source node to add to the route.

EID-5070

A destination node cannot be added to either of these lists.

Select a node other than the destination node to add to the route.

EID-5071

This node already belongs to one of these lists.

The node is already selected either in include or exclude list in the OCH circuit.

EID-5072

An OCH-Trail tunnel link was found but without any associated circuit.

Create an OCH-Trail circuit associated with the link.

EID-5073

You are creating an unprotected link from a protected port.
Do you want to continue?

Refer to the error message.

EID-5074

Deleting OCH DCN circuits will cause a loss of connectivity to nodes in the circuit path that do not have other DCN connections.
Do you want to continue?

Refer to the error message.

EID-5075

The VLAN ID must be a number between 1 and 4093.

Enter a number between 1 and 4093.

EID-5076

An error occurred while provisioning the VLAN ID.
The VLAN ID is already present in the current profile

Select a VLAN ID that is not present in the current profile.

EID-5077

An error occurred while provisioning the VLAN database profile.
{0}

CTC could not save the VLAN profile to the file name mentioned.

EID-5078

The VLAN merge is not complete.
You forgot to fill {0} record(s).

Fill in the number of records specified and then proceed.

EID-5079

An error occurred while validating the provisionable patchcord.

Refer to the error message text.

EID-5080

No rolls are available.

You cannot delete a roll without selecting a roll.

EID-5081

An error occurred while tracing the RPR ring:
{0}

The circuit reference is invalid.

EID-5082

{0} does not support:
- Low-order circuits that have both {1}-protected and {2}-protected spans and that cross a node that does not have low-order cross-connect capability.
- High-order circuits that carry low-order circuits with the parameters described above.

Refer to the error message text.

EID-5083

This circuit is not the same size as the existing circuit {0}.
This circuit has size {1} and the existing circuit has size {2}.

During an RPR circuit creation ML card, the new circuit size and the existing circuit size must be the same.

EID-5084

The Trunk model could not be found.
{0}

The trunk specified is not found.

EID-5085

The maximum number of VLAN DB profiles is {0}.

Refer to the error message.

EID-5086

The circuit roll failed.
You cannot bridge and roll the selected circuit because it has a monitor circuit.

Refer to the error message.

EID-5087

You cannot use same slot for east working and west protect ports.

Refer to the error message text.

EID-5088

You cannot use same slot for east working and west protect ports.

Refer to the error message text.

WID-5089

The maximum number of circuits that can be deleted at a time is 200.
Do you want to delete the first 200 circuits selected?

Refer to the error message text

EID-5090

This operation cannot be completed.
The selected circuits have different state models;
please select circuits of the same type.

Refer to the error message text

EID-5091

Some PPC terminations were not repaired.

Refer to the error message text

WID-5092

The TL1 encoding mode for the tunnel is being changed.
Do you want to modify the encoding?

Confirm if you really want to modify TL1 tunnel encoding.

EID-6000

This platform does not support power monitoring thresholds.

Refer to the error message text.

EID-6001

One of the XC cards has failures or is missing.

Check whether all the cross-connect cards are installed and working.

EID-6002

One of the XC cards is locked.

Unlock the cross-connect card.

EID-6003

The OSC termination could not be created.
This ring ID is already assigned.

Enter a new ID for the ring.

EID-6004

A system reset cannot be performed while a BLSR ring is provisioned on the node.

Remove the BLSR from the node and continue with the reset procedure.

EID-6005

The timing references could not be assigned.
- Only two DS1 or BITS interfaces can be specified.
- DS1 interfaces cannot be retimed and used as a reference.
- BITS-2 is not supported on this platform.

Refer to the error message text.

EID-6006

The timing references could not be assigned.
- An NE reference can only be used if the timing mode is LINE.
- A BITS reference can only be used if the timing mode is not LINE.
- A Line reference can only be used if the timing mode is not EXTERNAL.

Refer to the error message text.

EID-6008

SF BER and SD BER are not provisionable on the protect line of a protection group.

Refer to the error message text.

WID-6009

If autoadjust GFP buffers is disabled, GFP buffers available must be set to an appropriate value based on the distance between the circuit endpoints.

Refer to the warning message text.

WID-6010

If auto detection of credits is disabled, credits available must be set to a value less than or equal to the number of receive credits on the connected FC endpoint.

Refer to the warning message text.

WID-6011

Ingress idle filtering should be turned off only when required to operate with non-Cisco Fibre Channel/FICON-over-SONET equipment.

Refer to the warning message text.

EID-6012

The retiming configuration could not be changed because there are circuits on this port.

You cannot change the timing configuration on this port unless the circuits on this port are deleted.

EID-6013

The NTP/SNTP server could not be changed.

{1}

Refer to the error message text.

EID-6014

The operation failed because the reference state is OOS.

Change the Out-of-service state to Active.

EID-6015

The distance extension cannot be disabled if the port media type is FICON 1Gbps ISL or FICON 2Gbps ISL.

Refer to the error message text.

EID-6016

The card mode cannot be changed to Fibre Channel Line Rate if the port media type is FICON 1Gbps ISL or FICON 2Gbps ISL.

Refer to the error message text.

EID-6017

The destination of a {0} route cannot be a node IP address.

A node IP address cannot be the destination for a static route.

EID-6018

The destination of a {0} route cannot be the same as the subnet used by the node.

Refer to the error message text.

EID-6019

The destination of a static route cannot be 255.255.255.255

The network address such as 255.255.255.255 is not valid. Enter a valid address.

EID-6020

The destination of a static route cannot be the loopback network (127.0.0.0/8).

Refer to the error message text.

EID-6021

The subnet mask length for a non default route must be between 8 and 32.

Length of subnet mask must be within the specified range.

EID-6022

The subnet mask length for a default route must be 0.

Refer to the error message text.

EID-6023

The destination of a {0} route cannot be an internal network{1}.

The destination of a static route must not be an internal network.

EID-6024

The destination of a {0} route cannot be a class D (224.0.0.0/4) or class E (240.0.0.0/4) address.

The destination of a static route must not be a class D or class E address.

EID-6025

The destination of a {0} route cannot be a class A broadcast address (x.255.255.255/8).

The destination of a static route must not be a class A broadcast address. It should be (xxx.0.0.0).

EID-6026

The destination of a {0} route cannot be a class B broadcast address (x.x.255.255/16).

The destination of a static route must not be a class B broadcast address.

EID-6027

The destination of a {0} route cannot be a class C broadcast address (x.x.x.255/24).

The destination of a static route must not be a class C broadcast address.

EID-6028

The destination of a {0} route cannot be the subnet broadcast address associated with a node IP address.

The destination of a static route must not be a subnet broadcast address of a node IP.

EID-6029

The next hop of a static route cannot be the same as the destination of the route or an internal network{0}.

Static route must have the default route as the next hop, and not destination of the route or internal network.

EID-6030

The next hop of a static default route must be the provisioned default router.

The default route is selected for networks that do not have a specific route.

EID-6031

No more static routes can be created.

You have reached the maximum number of static routes.

EID-6032

This static route already exists.

Refer to the error message text.

EID-6033

A previous operation is still in progress.

Another operation is in progress. You must try after sometime.

EID-6035

The parent entity does not exist.

Refer to the error message text.

EID-6036

The parent PPM entity does not exist.

Create a parent entity for the PPM.

EID-6037

This equipment type is not supported.

CTC does not support this equipment.

EID-6038

The PPM port is invalid.

Refer to the error message text.

EID-6039

The card is part of a regeneration group.

Select another card.

EID-6040

Out of memory.

Refer to the error message text.

EID-6041

The port is already present.

Refer to the error message text.

EID-6042

The port is used as timing source.

Choose another port because the selected port is being used as a timing source.

EID-6043

A DCC or GCC is present.

Refer to the error message text.

EID-6044

The card or port is part of protection group.

Refer to the error message text.

EID-6045

The port has overhead circuit(s).

Refer to the error message text.

EID-6046

The ITU-T G.709 configuration is not compatible with the data rate.

Refer to the error message text.

EID-6047

The port cannot be deleted because its service state is OOS-MA,LPBK&MT.

To delete the port, you must change the port state to OOS-DSBLD.

EID-6048

{0} is {1}.

The trunk port is in the wrong state to carry out the action.

EID-6049

The card operating mode of {0} is not supported.

CTC does not support the mode of operation requested on the card.

EID-6050

Some {0} terminations were not {1}d.
{2}

Refer to the error message text.

WID-6051

All {0} terminations were {1}d successfully.
{2}

Refer to the warning message text.

EID-6052

The authentication key can not be blank.

Enter an authentication key.

EID-6053

No more SNMP trap destinations can be created.

You have reached the maximum number of SNMP trap destinations.

EID-6054

{0} is not a valid IP address for an SNMP trap destination.

The IP address specified is not a valid receiver of SNMP traps.

EID-6055

The IP address is already in use.

Refer to the error message text.

EID-6056

The SNMP trap destination is invalid. {0}

The specified SNMP trap destination is invalid. Choose another destination.

WID-6057

Changing the card mode will result in an automatic reset.

Refer to the warning message text.

EID-6058

The maximum number of IP-over-CLNS tunnels has been exceeded.

Refer to the error message text.

EID-6059

The specified IP-over-CLNS tunnel already exists!

Specify another IP Over CLNS tunnel.

EID-6060

An error occurred while trying to {0} an IP-over-CLNS tunnel entry:
{1}.

Refer to the error message text.

EID-6061

An error occurred while deleting the IP-over-CLNS tunnel entry.

CTC encountered an error while deleting the IP Over CLNS tunnel entry.

EID-6062

The selected IP-over-CLNS tunnel does not exist.

Create a IP Over CLNS tunnel.

EID-6063

The selected router does not exist.

Create a router.

EID-6064

The MAA address list is full.

Refer to the error message text.

EID-6065

The selected area address is duplicated.

Enter another area address.

EID-6066

The primary area address cannot be removed.

Refer to the error message text.

EID-6067

The selected area address does not exist.

Choose another area address.

EID-6068

The IP-over-CLNS NSEL cannot be modified while there are IP-over-CLNS tunnel routes provisioned.

You cannot change the NSEL address if tunnels are provisioned.

EID-6069

The node is currently in ES mode. Only Router 1 can be provisioned.

An End System needs only one provisioned router.

EID-6070

No router was selected.

Select a router.

EID-6071

The TARP data cache cannot be flushed.

You cannot flush the cache in the Tunnel identifier Address Resolution Protocol (TARP) state.

EID-6072

The TARP data cache entry cannot be added:
{0}

You cannot add the specified cache entry.

WID-6073

A TARP request has been initiated.
Try refreshing the TARP data cache later.

Refer to the warning message text.

EID-6074

End system mode only supports one subnet.

Refer to the error message text.

EID-6075

An error occurred while trying to remove a MAT entry. The entry does not exist.

CTC is removing the MAT entry.

EID-6076

An error occurred while trying to {0} a TARP manual adjacency entry:
{1}

CTC cannot add the specified adjacency entry for reasons unknown.

EID-6077

The area address must be between 1 and 13 bytes long, inclusive.

The area address should not be more than 13 characters.

EID-6078

A TDC entry with this TID {0} does not exist in the table.

The specified Tunnel Identifier does not exist.

EID-6079

A TDC entry with this TID {0} could not be removed.
Please verify that TARP is enabled.

You must enable TARP to remove the TDC entry.

WID-6080

Router {0} does not have an area address in common with Router 1. Switching from IS L1/L2 to IS L1 in this case will partition your network.

Refer to the warning message text.

EID-6081

The limit of 10 RADIUS server entries has been reached.

CTC does not allow more than 10 RADIUS servers.

EID-6082

{0} cannot be empty.

The Shared Secrets field should not be empty.

EID-6083

The entry you selected for editing has been altered by another user. The changes cannot be committed.

Refer to the error message text.

EID-6084

The RADIUS server entry already exists.

Specify another RADIUS server entry.

WID-6085

Disabling shell access will prevent Cisco TAC from connecting to the vxWorks shell to assist users.

Refer to the warning message text.

EID-6086

The card cannot be changed because card resources are in use.

The card you are trying to remove is being used. Cannot change the card.

EID-6087

The card cannot be changed because the card type is invalid or incompatible.

Refer to the error message text.

EID-6088

This line cannot be put into loopback while it is in use as a timing source.

Refer to the error message text.

EID-6089

The interface was not found. {0}

CTC cannot find the specified interface.

EID-6090

The interface type is not valid for this operation. {0}

Choose another interface.

EID-6091

The current state of the interface prohibits this operation. {0}

The port is in an invalid state to set a loopback.

EID-6092

This operation is prohibited for this interface. {0}

CTC does not allow this operation for the specified interface.

EID-6093

The maximum number of TARP data cache entries has been exceeded.

You have exceeded the number of characters permitted.

EID-6094

The maximum number of manual adjacency table entries has been exceeded.

Refer to the error message text.

EID-6095

The AIS/Squelch mode is invalid.

Refer to the error message text.

EID-6096

A default IP-over-CLNS tunnel route is only allowed on a node without a default static route and a default router of 0.0.0.0.

Refer to the error message text.

EID-6097

The authorization key does not comply with Cisco IOS password restrictions.
{0}

Specify another authorization key.

EID-6098

A default static route is not allowed when a default IP-over-CLNS tunnel exists.

Refer to the error message text.

EID-6099

You cannot create a subnet on a disabled router.

Create the subnet on an active router.

WID-6100

Disabling a router that has a provisioned subnet is not recommended.

Refer to the warning message text.

EID-6101

The MAT entry already exists.

Refer to the error message text.

WID-6102

The new card has less bandwidth than the current card. Circuits of size VT15 and larger will be deleted.

Refer to the warning message text.

EID-6103

The TDC entry already exists.

Specify another entry for TARP Data Cache.

EID-6104

APC ABORTED.

Automatic Power Control is aborted.

EID-6105

The 'Change Card' command is valid for MRC cards only when Port 1 is the sole provisioned port.

Refer to the error message text.

EID-6106

To delete all RADIUS server entries, RADIUS authentication must be disabled.

Disable Radius authentication and proceed.

EID-6107

The node failed to restart the TELNET service on the selected port. Try using another unreserved port that is not being used within the following ranges:
23, 1001-9999 (with the exception of 1080, 2001-2017, 2361, 3081-3083, 4001-4017, 4022, 4081, 4083, 5000, 5001, 7200, 9100, 9300, 9401).

Refer to the error message text.

EID-6108

That port is already in use.

Restart a TELNET session.

EID-6109

A section trace is active on the trunk port. The action cannot be completed.

Actions such as putting the port in an incomplete state are not permitted while a section trace is active.

EID-6110

The maximum number of TARP requests has been reached.

You have exceeded the maximum number of TARP requests.

EID-6111

The card in Slot {0} cannot be removed from the protection group while its traffic is switched.

Refer to the error message text.

EID-6112

An error occurred while adding a shelf: {0}

The shelf ID specified is invalid or already exists, the equipment does not support multishelf, the specified shelf position is out of range, or the specified shelf position is already in use.

EID-6113

An error occurred while deleting a shelf: {0}

One or more of the equipment modules (provisioned virtual links, provisioned server trails, provisioned protection groups, or provisioned DCCs) in the shelf is currently in use. Delete cards from all the slots and try again.

EID-6114

The maximum number of supported shelves has already been provisioned.

Refer to the error message text.

EID-6115

There are bad or duplicate shelf positions.
Valid rack numbers are {0} to {1}.
Valid rack positions are {2} to {3}.

Refer to the error message text.

EID-6116

CTC attempted to access an OCH-Trail connection that has been destroyed.

Software has prevented an attempt to access an OCH trail.

EID-6117

CTC attempted to access an OCH-Trail audit that has been destroyed.

The resource cannot be accessed because it is released or fully utilized.

WID-6118

The following slots are provisioned but do not have cards installed:
{0}
CTC will assume they are ITU-T interfaces.

Refer to the warning message text.

EID-6119

The shelves could not be rearranged.
{0}

One of the following conditions is present: duplicate shelf positions, invalid shelf positions, or concurrent movement (two CTC sessions are attempting to rearrange the shelves at the same time.)

EID-6120

This equipment does not support multishelf.

Refer to the error message text.

WID-6121

This internal patchcord cannot be provisioned because the endpoints have no compatible wavelengths.

The end points of an internal patchcord should have compatible wavelengths.

EID-6122

The wizard could not be started.
{0}

CTC was unable to initiate the wizard due to the specified reason.

EID-6123

The OSI request can not be completed successfully.

A communication failure occurred.

EID-6124

The ALS recovery pulse interval is invalid.

Refer to the error message text.

EID-6125

The ALS recovery pulse duration is invalid.

Refer to the error message text.

EID-6126

The current setting does not support the specified ALS mode.

Refer to the error message text.

EID-6127

All enabled routers are required to have the same area.

Refer to the error message text.

EID-6128

A software download is in progress. Configuration changes that result in a card reboot cannot take place during a software download.
Please try again after the software download is done.

Refer to the error message text.

EID-6129

The payload configuration and card mode are incompatible.

Refer to the error message text.

EID-6135

A DCC is present.

A data communication channel (DCC) already exists.

EID-6136

An error occurred during provisioning: {0}

CTC was not able to provision the specified port or card.

EID-6137

Multishelf cannot be disabled.
{0}

Multishelf is not supported on equipment, is already disabled, or modules on the shelf are currently in use.

EID-6138

The LAN configuration is invalid.

Verify the LAN configuration.

EID-6139

Invalid card(s) are present.
Please remove all non-MSTP cards and try again.

Non-DWDM cards cannot be added to an a DWDM node. Remove the cards.

EID-6140

The shelf identifier for a subtended shelf cannot be provisioned through CTC. It must be changed using the LCD.

Refer to the error message text.

EID-6143

The DHCP server could not be changed.

Refer to the error message text.

EID-6144

The port provisioning cannot be changed when the port media is Undefined.

If the port is not pre-provisioned with the type of media that is going to be inserted, you cannot access any of the existing values for the port.

WID-6145

OSPF on LAN should only be enabled when the LAN routers run OSPF. Otherwise, the node will not be reachable from outside its subnet.
RIP implementation only advertise routes in one direction to connected routers. It does not learn or distribute routes advertised by other routers.
Also note that enabling OSPF on the LAN will temporarily cause the current list of static routes to stop being advertised to remote nodes and only be used locally.

Refer to the warning message text.

WID-6146

Deleting the protection group while in a switched state might cause a loss of traffic. It is recommended that you verify switch states before proceeding.

Refer to the warning message text.

EID-6149

The LAPD MTU size must be greater than or equal to the {0} LSP buffer size {1}. Alternatively, you can decrease the {0} LSP buffer size to {2}.

Refer to the error message text.

EID-6150

The value is out of range.

Enter a value that is within the range.

EID-6151

The minimum span loss must be less than the maximum span loss.

Refer to the error message text.

EID-6152

The "Use NTP/SNTP Server" field is checked. Enter the NTP/SNTP server IP address or server name.

Enter the NTP/SNTP server name. To leave this field empty, uncheck the "Use NTP/SNTP Server" and proceed.

EID-6153

The maximum frame size is invalid.

Refer to the error message text.

EID-6154

To combine unidirectional two-port provisioning and autonegotiation on the same port, autonegotiation must be set first.

Refer to the error message text.

EID-6155

Transponder mode cannot be provisioned with circuits on the card.

Refer to the error message text.

EID-6156

The transponder configuration is invalid.

The transponder is not configured properly.

EID-6157

The watermark values are either out of range or inconsistent.

Enter valid watermark values.

EID-6179

The 1+1 protection group is not optimized.

Refer to the error message text.

EID-6196

The equipment has failed or is missing.

Operation is requested on a failed or missing equipment.

EID-6197

Attributes cannot be changed when the port administrative state is {0}.

You cannot change the attributes when the port is in the specified administrative state.

WID-6204

This action will cause the node to reboot. When provisioning in single-shelf mode, Shelf {0} of the node that you connect to must be properly preprovisioned or you will lose traffic.
Use the LCD to return to single-shelf mode. CTC cannot be used for this.
Changing from subtended shelf mode to single-shelf mode could be traffic-affecting.

Refer to the warning message text.

EID-6205

The interlink port is not provisioned.

The user creates an ADM peer group without interlink ports.

EID-6206

The ADM peer group has already been created on the peer card.

The user creates an ADM peer group involving an ADM card inserted in a peer group.

EID-6207

This card is not in the ADM peer group.

The selected ADM card is not involved in an ADM peer group.

EID-6208

The payload is not OTU2.

Refer to the error message text.

EID-6209

The side is already defined by the node.

During the creation of a side on node, a side is already defined.

EID-6210

No side was selected.

The user requests an operation on a side, but no side is selected.

EID-6211

The side was not deleted.

CTC could not delete the selected side successfully.

EID-6212

One of the ports is connected to a patchcord or virtual link.

An operation on a port was not performed because the port is connected to a patchcord or a virtual link.

EID-6213

It is not possible to associate the side to the two ports.

During the creation of a side it is not possible to associate the selected ports to the new side.

EID-6214

The port is already assigned to a side.

The selected port is already assigned to a side.

EID-6215

Error provisioning the CVLAN ID.
Enter a valid number or range between 0 and 4094.

The entered CVLAN ID was out of the admitted range.

EID-6216

Changing card will reset the optical thresholds to the default setting and may affect the optical connection.
The optical connection will work only if the optical performance is compatible with {0} card.
Please check the network design.

Refer to the error message text.

EID-6217

You cannot delete the {0} {1}.

You cannot delete {0} {1} because it is part of an ADM peer group or one or more circuits are provisioned on it.

EID-6218

Invalid ethernet duplex value

the Ethernet duplex value is invalid. Enter again.

EID-6219

Invalid committed info rate

The committed info rate value is invalid. Enter again.

EID-6220

Invalid mode value

The mode value is invalid. Enter again.

EID-6221

Invalid mtu value

The MTU value is invalid. Enter again.

EID-6222

Invalid flow control value

The flow control value is invalid. Enter again.

EID-6223

Invalid Network Interface Mode

The network interface mode value is invalid. Enter again.

EID-6224

Invalid ingress COS value

The ingress COS value is invalid. Enter again.

EID-6225

Invalid ethertype value

The Ethertype value is invalid. Enter again.

EID-6226

Invalid buffer size value

The Buffer size value is invalid. Enter again.

EID-6227

Invalid egress QOS value

The egress QOS value is invalid. Enter again.

EID-6228

Invalid QinQ working Mode

The QinQ working mode is invalid. Enter again.

EID-6229

Configured protection status Not Supported

The protection status is not supported

EID-6230

The number of provisioned entries exceeds the limit

Refer to the error message text.

EID-6231

This is not a valid VLAN ID.

Entered VLAN ID is not present in the database file.

EID-6232

The VLAN remapping ID is not allowed.

Refer to the error message text.

EID-6233

The CVLAN is duplicated.

You cannot have identical CVLAN IDs.

EID-6234

The VLAN ID is out of range.

The VLAN ID entered is out of range.

EID-6235

This is not a valid VLAN name.

The entered VLAN name exceeds the number of characters (32) allowed.

EID-6236

The protected VLAN number exceeds the maximum allowed.

The user enters more than 256 protected VLAN in the VLAN database.

EID-6237

The port is not in OOS disabled admin state

Refer to the error message text.

EID-6238

The VLAN ID is in use.

The entered VLAN ID is in use by a node.

EID-6239

APC wrong node side.

Refer to the error message text.

EID-6240

You cannot change the Admin State for an interlink port when it is part of an ADM peer group. This operation is not supported.

Refer to the error message text.

EID-6242

The protection slot is invalid.

You must select a valid protection slot.

EID-6243

The {0} address of {1} is invalid.

Refer to the error message text.

EID-6244

The mask of {0} is invalid.

The mask of the specified value is not valid.

EID-6245

The cost must be between 1 and 32767.

Refer to the error message text.

EID-6246

The {0} address cannot be {1}.

Refer to the error message text.

EID-6247

The authentication type is invalid.

Enter a valid authentication type.

EID-6248

The cost must between 1 and 15.

Refer to the error message text.

EID-6249

The port has a cross-connect.

Refer to the error message text.

EID-6250

The reversion time is invalid.

The reversion time is invalid. Enter again.

EID-6251

Invalid Margin For Span Aging.
Value is not in the range 0 - 10.

Enter a value between 0 and 10.

EID-6252

The data cannot be retrieved because ANS parameters cannot be calculated on the node in its current configuration.

Refer to the error message text.

EID-6253

Invalid Margin For Span Aging.

Refer to the error message text.

EID-6254

SDH mode does not support timing references.

Timing reference is not supported by SDH mode.

EID-6255

Only DS1 interfaces with ESF line types support timing references.

Refer to the error message text.

EID-6256

sendDoNotUse and sendDoNotUseFF are mutually exclusive.

Refer to the error message text.

EID-6257

The termination is already in use.

Refer to the error message text.

EID-6258

The side is carrying services or traffic.

Refer to the error message text.

EID-6259

A pluggable module on Port 22 remains unmanaged.

Refer to the error message text.

EID-6260

You cannot delete this port.
There was a severe architectural error related to the index of the pluggable trunk port object.
Please contact technical support for assistance.

Refer to the error message text.

EID-6261

This is not a valid VLAN ID. The VLAN database is empty.

The user adds a row without a valid VLAN database loaded.

EID-6263

The equipment requires two slots.

The user provisions a double footprint card in a single slot.

EID-6264

The patchcord is duplicated.

Refer to the error message text.

EID-6265

The wavelength is in use by an OCH trail, a virtual link, or an internal patchcord.

Refer to the error message text.

EID-6266

The card cannot be changed because the port has not been provisioned.

Refer to the error message text.

EID-6267

Each port can have a maximum of 8 MAC addresses.

Refer to the error message text.

EID-6268

This server trail does not have a valid start or end.

Refer to the error message text.

EID-6269

The maximum number of server trails is 3743.

Refer to the error message text.

EID-6270

A unique server trail ID could not be allocated.

Refer to the error message text.

EID-6271

The server trail already exists.

Refer to the error message text.

EID-6272

The server trail size must not exceed the port bandwidth.

Refer to the error message text.

EID-6273

An OCH Trail circuit is active on the trunk port.
To modify the ITU-T G.709 parameter, the circuit must be out of service.

Refer to the error message text.

EID-6274

Unable to restore this database:
The software version cannot be obtained from the node. Please try again.

Refer to the error message text.

EID-6275

You cannot change this parameter.
The port is part of an active circuit.

Certain parameters like Port Rate and Admin State cannot be changed when the port is part is part of an active circuit. Delete all the circuits on the port before changing admin state of the port.

EID-6276

APC is disabled. APC Correction Skipped. Override cannot be performed.

Refer to the error message text.

EID-6277

There are no alarm conditions available to run APC Correction Skipped Override.

Refer to the error message text.

EID-6278

APC Correction Skipped Override is not supported for this card.

Refer to the error message text.

EID-6279

Protection cannot be disabled when the FPAS alarm is active.

Refer to the error message text.

WID-6280

Any configuration change will be lost and the operation is traffic affecting.

Refer to the error message text.

EID-6281

The port is involved in a protection group.
The protected port is not in the {0} administrative state

Change the port state to administrative.

WID-6282

Forcing FPGA update will be traffic-affecting.

Refer to the error message text.

WID-6283

Enabling ALS on a DWDM trunk port that is connected to a channel filter
will result in a conflict with the ALS on the amplifier card or with the
VOA startup process. Is it OK to continue?

Refer to the error message text.

WID-6284

Changing the timing standard will re-initialize the shelf timing
and might affect traffic.

OK to continue?

Refer to the error message text.

WID-6285

Since you are changing the IP address of one node containing some PPC terminations,
you are also requested to run the PPC Repair tool in order to fix the IP addresses stored
in the nodes connected by these PPCs

Refer to the error message text.

EID-6286

The port type cannot be changed because the port has been deleted.

Refer to the error message text.

EID-6287

You cannot edit the {0} {1}.

Port rate of Optical and Electrical ports cannot be changed while circuits are provisioned on them.

EID-6288

The BERT configuration is invalid.

Refer to the eror message text.

EID-6289

The BERT mode is not yet configured

Refer to the error message text.

WID-6290

The BERT mode is configured in unframed format

Refer to the error message text.

WID-6291

Port has circuits; configuring the BERT mode will disrupt normal traffic.

Refer to the error message text.

EID-6292

The alarm type name cannot exceed 20 characters

Refer to the error message text.

EID-6294

The alarm type name contains invalid characters.
Only the following characters are valid: 0-9, A-z, a-z and "-".

Refer to the error message text.

EID-6295

The alarm type is in use and cannot be deleted.

Refer to the error message text.

EID-6296

Maximum number of alarm types that can be added cannot exceed 50.

Refer to the error message text.

EID-6297

Hard coded alarm types cannot be deleted.

Refer to the error message text.

EID-6298

The alarm type already exists.

Refer to the error message text.

EID-6299

The alarm type does not exist.

Refer to the error message text.

EID-6300

Selective auto negotiation is allowed only when
selected speed and duplex modes are non-auto.
Click "Reset" to revert the changes.

Refer to the error message text.

WID-6301

Selective auto negotiation applies only to copper SFPs.

Refer to the error message text.

EID-6302

Users are not allowed to perform this operation.

When logged in as a maintainence user provisioning operation is not allowed.

EID-6303

The ITU-T G.709 configuration cannot be disabled
when Fast Protection is enabled.

Refer to the error message text.

1 EID-3159 can appear if you attempt to perform another switching operation within a certain time interval. This interval is an algorithm of three seconds per working card in the protection group. The maximum interval is 10 seconds.



hometocprevnextglossaryfeedbacksearchhelp

Posted: Mon Oct 1 23:05:34 PDT 2007
All contents are Copyright © 1992--2007 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.