Conditions


Conditions



Note The terms "Unidirectional Path Switched Ring" and "UPSR" may appear in Cisco literature. These terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring configuration. Rather, these terms, as well as "Path Protected Mesh Network" and "PPMN," refer generally to Cisco's path protection feature, which may be used in any topological network configuration. Cisco does not recommend using its path protection feature in any particular topological network configuration.


This chapter describes the conditions for TL1 commands and autonomous messages for the Cisco ONS 15454, ONS 15327, ONS 15310-CL, ONS 15310-MA, and ONS 15600.

Conditions include any problem detected on an ONS 15454, ONS 15327, ONS 15310-CL, ONS 15310-MA, or ONS 15600 shelf. They can include standing or transient notifications. A snapshot of all currently raised standing conditions on the network, node, or card can be retrieved in the Cisco Transport Controller (CTC) Conditions window or using the RTRV-COND commands. (In addition, some but not all cleared conditions are found in the CTC History tab.)

Table 26-1 Conditions 

Condition
Description

AIS

Alarm Indication Signal

AIS-L

Alarm Indication Signal-Line

AIS-P

Alarm Indication Signal-Path

AIS-V

Alarm Indication Signal-VT

ALS

Automatic Laser Shutdown

APC-DISABLED

Automatic Power Control Disabled

APC-FAIL

Automatic Power Control Failure

APSB

Byte Failure

APSC-IMP

Improper Automatic Protection Switch (APS) Code

APSCDFLTK

Default K Byte

APSCINCON

Inconsistent APS Code

APSCM

Protection Switching Channel Match Failure

APSCNMIS

Node ID Mismatch

APSIMP

APS Invalid Mode

APSMM

Automatic Protection Switch Mode Mismatch

AS-CMD

Alarms Suppressed By User Command

AS-MT

Alarms Suppressed For Maintenance

AU-LOF

Loss of Frame (LOF)-Administration Unit-Loss of Multiframe

AUD-LOG-LOSS

Audit Log 100 Percent Full-Oldest records will be lost

AUD-LOG-LOW

Audit Log 80 Percent Full

AUTOLSROFF

Automatic Laser Shutoff Due To High Temperature

AUTORESET

Automatic System Reset

AUTOSW-AIS

Automatic path protection Switch Caused By AIS

AUTOSW-LOP

Automatic path protection Switch Caused By LOP

AUTOSW-PDI

Automatic path protection Switch Caused By PDI

AUTOSW-SDBER

Automatic path protection Switch Caused By SDBER

AUTOSW-SFBER

Automatic path protection Switch Caused By SFBER

AUTOSW-UNEQ

Automatic path protection Switch Caused By UNEQ

BAT-FAIL

Battery Failure

BAT-HGH-VLT

High Volt

BAT-LOW-VLT

Low Volt

BKUPMEMP

Primary Nonvolatile Backup Memory Failure

BLSROSYNC

BLSR Out Of Sync

CARLOSS

Carrier Loss On The LAN

CKTDOWN

Signaling Unable to Set Up Circuit

CLDRESTART

Cold Restart

COMIOXC

Input/Output (IO) Slot To Cross-connect (XCON) Communication Failure

COMM-FAIL

Plug-in Module Communication Failure

CONTBUS-A-18

TCC A To DCC A Processor Communication Failure

CONTBUS-B-18

TCC B To DCC B Processor Communication Failure

CONTBUS_A

Controller A To Shelf Slot Communication Failure

CONTBUS_B

Controller B To Shelf Slot Communication Failure

CTNEQPT-MISMATCH

Connection Equipment Mismatch

CTNEQPT-PBPROT

Interconnection Equipment Failure-Protect XC Payload Bus

CTNEQPT-PBWORK

Interconnection Equipment Failure-Working XC Payload Bus

DATAFLT

Software Fault-Data Integrity Fault

DBOSYNC

Standby Database Out of Synchronization

DS3-MISM

DS3 Frame Format Mismatch

DSP-COMM-FAIL

DSP Communication Failure

DSP-FAIL

DSP Failure

DUP-IPADDR

IP address already in use within the same data communications channel (DCC) area

DUP-NODENAME

Node name already in use within the same DCC area

E-W-MISMATCH

Both Ends Of Fiber Provisioned As East Or Both As West

EHIBATVG

Extreme High Voltage

ELWBATVG

Extreme Low Voltage

EOC

Section DCC (SDCC) Termination Failure

EOC-L

Line DCC (LDCC) Termination Failure

EQPT

Equipment Failure

EQPT-MISS

Replaceable Equipment/Unit is Missing

ERFI-P-CONN

Enhanced Remote Failure Indication-Path-Connectivity

ERFI-P-PAYLD

Enhanced Remote Failure Indication-Path-Payload

ERFI-P-SRVR

Enhanced Remote Failure Indication-Path-Server

ERROR-CONFIG

Error in Startup Configuration

ETH-LINKLOSS

Rear Panel Ethernet Link Removed

EXCCOL

Excess Collisions on the LAN

EXERCISE-RING-FAIL

Exercise Request on Ring Failed

EXERCISE-RING-REQ

Exercise Request on Ring

EXERCISE-SPAN-FAIL

Exercise Request on Span Failed

EXERCISE-SPAN-REQ

Exercise Request on Span

EXT

Failure Detected External To The NE

EXTRA-TRAF-PREEMPT

Extra Traffic Preempted

FAILTOSW

Failure To Switch To Protection

FAILTOSW-PATH

Failure To Switch To Protection-Path

FAILTOSWR

Failure To Switch To Protection-Ring

FAILTOSWS

Failure To Switch To Protection-Span

FAN

Fan Failure

FANDEGRADE

Partial Fan Failure

FE-AIS

Far End AIS

FE-DS1-MULTLOS

Far End Multiple DS1 LOS Detected On DS3

FE-DS1-NSA

Far End DS1 Equipment Failure-Non-Service-Affecting

FE-DS1-SA

Far End DS1 Equipment Failure-Service-Affecting

FE-DS1-SNGLLOS

Far End Single DS1 Loss of Signal (LOS)

FE-DS3-NSA

Far End DS3 Equipment Failure-Non-Service-Affecting

FE-DS3-SA

Far End DS3 Equipment Failure-Service-Affecting

FE-EQPT-NSA

Far End Common Equipment Failure-Non-Service-Affecting

FE-EXERCISING-RING

Far End Exercising Ring

FE-EXERCISING-SPAN

Far End Exercising Span

FE-FRCDWKSWPR-RING

Far End Working Facility Forced To Switch To Protection-Ring

FE-FRCDWKSWPR-SPAN

Far End Working Facility Forced To Switch To Protection-Span

FE-IDLE

Far End Idle

FE-LOCKOUTOFPR-SPAN

Far End Lockout Of Protection-Span

FE-LOF

Far End LOF

FE-LOS

Far End LOS

FE-MANWKSWPR-RING

Far End Manual Switch Of Working Facility To Protection-Ring

FE-MANWKSWPR-SPAN

Far End Manual Switch Of Working Facility To Protection-Span

FEC-MISM

FEC Mismatch

FEPRLF

Far End Protection Line Failure

FORCED-REQ

Forced Switch Request

FORCED-REQ-RING

Forced Switch Request On Ring

FORCED-REQ-SPAN

Forced Switch Request On Span

FRCDSWTOINT

Forced Switch To Internal Clock

FRCDSWTOPRI

Forced Switch To Primary Reference

FRCDSWTOSEC

Forced Switch To Second Reference

FRCDSWTOTHIRD

Forced Switch To Third Reference

FRNGSYNC

Free Running Synchronization Mode

FSTSYNC

Fast Start Synchronization Mode

FULLPASSTHR-BI

Bidirectional Full Pass Through Is Active

GCC-EOC

GCC Termination Failure

GE-OOSYNC

Gigabit Ethernet Out of Synchronization

HI-LASERBIAS

Equipment High Laser Bias

HI-RXPOWER

Equipment High Receive (Rx) Power

HI-TXPOWER

Equipment High Transmit (Tx) Power

HITEMP

High Temperature

HLDOVRSYNC

Holdover Synchronization Mode

I-HITEMP

Industrial High Temperature

IMPROPRMVL

Improper Removal

INC-GFP-OUTOFFRAME

Out Of Frame Detected by Generic Framing Procedure (GFP) Receiver

INC-GFP-SIGLOSS

Client Signal Loss Frames Detected by GFP Receiver

INC-ISD

DS3 Idle Condition

INC-SIGLOSS

Incoming Signal Loss on Fibre Channel Interface

INC-SYNCLOSS

Incoming Synchronization Loss on Fibre Channel Interface

INC_GFP_SYNCLOSS

Client Synchronization Loss Frames Detected by GFP Receiver

INHSWPR

Inhibit Switch To Protect Request On Equipment

INHSWWKG

Inhibit Switch To Working Request On Equipment

INTRUSION-PSWD

Security Intrusion Attempt Detected-See Audit Log

INVMACADR

Invalid MAC Address

IOSCFGCOPY

IOS Configuration Copy In Progress

KB-PASSTHR

K Byte Pass Through Is Active

KBYTE-APS-CHANNEL-FAILURE

K Byte Channel Failure

LAN-POL-REV

LAN Connection Polarity Reversed

LASEREOL

Laser Approaching End of Life

LKOUTPR-S

Lockout Of Protection-Span

LMP-HELLODOWN

LMP Hello FSM to Control Channel Down

LMP-NDFAIL

LMP Neighbor Discovery has failed

LO-RXPOWER

Equipment Low Rx Power

LO-TXPOWER

Equipment Low Tx Power

LOA

Loss of Alignment

LOC

Loss of Channel

LOCKOUT-REQ

Lockout Switch Request On Facility or Equipment

LOCKOUT-REQ-RING

Lockout Switch Request On Ring

LOF

Loss Of Frame

LOM

Loss of Multiframe

LOP-P

Loss Of Pointer-Path

LOP-V

Loss Of Pointer-VT

LOS

Loss Of Signal

LPBKCRS

Cross-connect Loopback

LPBKDS1FEAC

DS1 Loopback Due To FEAC Command

LPBKDS1FEAC-CMD

DS1 Loopback Command Sent To Far End

LPBKDS3FEAC

DS3 Loopback Due To FEAC Command

LPBKDS3FEAC-CMD

DS3 Loopback Command Sent To Far End

LPBKFACILITY

Facility Loopback

LPBKTERMINAL

Terminal Loopback

LWBATVG

Low Volt

MAN-REQ

Manual Switch Request

MANRESET

Manual System Reset

MANSWTOINT

Manual Switch To Internal Clock

MANSWTOPRI

Manual Switch To Primary Reference

MANSWTOSEC

Manual Switch To Second Reference

MANSWTOTHIRD

Manual Switch To Third Reference

MANUAL-REQ-RING

Manual Switch Request On Ring

MANUAL-REQ-SPAN

Manual Switch Request On Span

MEA

Mismatch Of Equipment And Attributes

MEM-GONE

Free Memory On Card Near Zero

MEM-LOW

Free Memory On Card Very Low

MFGMEM

Manufacturing Data Memory (EEPROM Failure)

NO-CONFIG

No Startup Config

NTWTPINC

Network Topology Incomplete

OCHNC-ACTIV-FAIL

Optical Channel Activation Failure

OCHNC-DEACTIV-FAIL

Optical Channel Deactivation Failure

OCHNC-FAIL

Optical Channel Connection Failure

OCHNC-INC

Optical Channel Incomplete

ODUK-AIS-PM

ODUk: Alarm Indication Signal

ODUK-BDI-PM

ODUk: PM Backward Defect Indication

ODUK-LCK-PM

ODUk: Locked Defect-PM

ODUK-OCI-PM

ODUk: Open Connection Indication

ODUK-SD-PM

ODUk: Signal Degrade

ODUK-SF-PM

ODUk: Signal Failure

ODUK-TIM-PM

ODUk: Trail Trace Identifier Mismatch

OOU-TPT

Out of Use-Transport Failure

OPTNTWMIS

Optical Network Type Mismatch

OTUK-AIS

OTUk: Alarm Indication Signal

OTUK-BDI

OTUk: Backward Defect Indication

OTUK-LOF

OTUk: Loss Of Frame

OTUK-SD

OTUk: Signal Degrade

OTUK-SF

OTUk: Signal Failure

OTUK-TIM

OTUk: Trail Trace Identifier Mismatch

OUT-OF-SYNC

8B10B Out of Sync

PDI-P

Payload Defect Indication-Path

PEER-NORESPONSE

Peer Card Not Responding

PLM-P

Payload Label Mismatch-Path

PLM-V

Signal Label Mismatch Failure-Payload Label Mismatch-VT

PORT-CODE-MISM

Pluggable Port security code mismatch

PORT-COMM-FAIL

Module Communication Failure

PORT-MISMATCH

Pluggable Port rate mismatch

PORT-MISSING

Pluggable Port missing

PRC-DUPID

Duplicate Node ID

PROTNA

Protection Unit Not Available

PTIM

Payload Type Identifier Mismatch

PWR-REDUN

Redundant Power Capability Lost

RAI

Remote Alarm Indication

RCVR-MISS

Facility Termination Equipment-Receiver Missing

RFI

Remote Failure Indication

RFI-L

Remote Failure Indication-Line

RFI-P

One-Bit Remote Failure Indication-Path

RFI-V

Remote Failure Indication-VT

RING-ID-MIS

Ring ID Mismatch

RING-MISMATCH

Far End of Fiber Is Provisioned With Different Ring ID

RING-SW-EAST

Ring Switch Is Active on the East Side

RING-SW-WEST

Ring Switch Is Active on the West Side

RSVP-HELLODOWN

RSVP Hello FSM to Neighbor Down

RUNCFG-SAVENEED

Need to Save Running Configuration

SD

Signal Degrade

SD-L

Bit Error Rate (BER) Threshold Exceeded For Signal Degrade-Line

SD-P

BER Threshold Exceeded For Signal Degrade-Path

SF

Signal Failure

SF-L

BER Threshold Exceeded For Signal Failure-Line

SF-P

BER Threshold Exceeded For Signal Failure-Path

SFTWDOWN

Software Download In Progress

SNTP-HOST

Simple Network Time Protocol (SNTP) Host Failure

SPAN-SW-EAST

Span Switch Is Active On The East Side

SPAN-SW-WEST

Span Switch Is Active On The West Side

SQM

Sequence Mismatch

SQUELCH

Ring Is Squelching Traffic

SQUELCHED

Equipment Squelched

SSM-DUS

Do Not Use For Synchronization

SSM-FAIL

Failed To Receive Synchronization Status Message

SSM-LNC

G812-Local Node Clock Traceable

SSM-OFF

Synchronization Status Messages Are Disabled On This Interface

SSM-PRC

G811-Primary Reference Clock Traceable

SSM-PRS

Stratum 1 Primary Reference Source Traceable

SSM-RES

Reserved For Network Synchronization Use

SSM-SDH-TN

G812-Transit Node Clock Traceable

SSM-SETS

G813-Synchronous Equipment Timing Source Traceable

SSM-SMC

SONET Minimum Clock Traceable

SSM-ST2

Stratum 2 Traceable

SSM-ST3

Stratum 3 Traceable

SSM-ST3E

Stratum 3E Traceable

SSM-ST4

Stratum 4 Traceable

SSM-STU

Synchronized-Traceability Unknown

SSM-TNC

Transit Node Clock Traceable

SWMTXMOD

Switching Matrix Module Failure

SWTOPRI

Switch To Primary Reference

SWTOSEC

Switch To Second Reference

SWTOTHIRD

Switch To Third Reference

SYNC-FREQ

Synchronization Reference Frequency Out Of Bounds

SYNCPRI

Primary Synchronization Reference Failure

SYNCSEC

Secondary Synchronization Reference Failure

SYNCTHIRD

Third Synchronization Reference Failure

SYSBOOT

System Reboot

TIM

TIM Section-Trace Identifier Mismatch Failure

TIM-MON

TIM Section Monitor-Trace Identifier Mismatch Failure

TIM-P

STS Path Trace Identifier Mismatch

TPTFAIL

Transport layer failure

TRMT

Transmit Failure

TRMT-MISS

Facility Termination Equipment-Transmitter Missing

TUNDERRUN

Ether Tx Under-run

TX-AIS

Alarm Indication Signal in Tx

TX-RAI

Remote Alarm Indication in Tx

UNC-WORD

Forward Error Correction (FEC) Uncorrected Word

UNEQ-P

Unequipped-Path

UNEQ-V

Signal Label Mismatch Failure-Unequipped VT

VCG-DEG

Virtual Concatenation (VCAT) Group Degraded

VCG-DOWN

VCAT Group Down

WKSWPR

Switched To Protection

WTR

Wait To Restore

WVL-MISMATCH

Equipment Wavelength Mismatch