cc/td/doc/product/ong/15400/r72docs
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table Of Contents

Hardware Specifications

A.1  Shelf Specifications

A.1.1  Bandwidth

A.1.2  Configurations

A.1.3  Cisco Transport Controller

A.1.4  External LAN Interface

A.1.5  TL1 Craft Interface

A.1.6  Modem Interface

A.1.7  Alarm Interface

A.1.8  EIA Interface (ANSI only)

A.1.9  BITS Interface (ANSI only)

A.1.10  System Timing

A.1.11  System Power

A.1.12  System Environmental Specifications

A.1.13  Dimensions

A.2  General Card Specifications

A.2.1  Power

A.2.2  Temperature

A.3  Common Control Card Specifications

A.3.1  TCC2 Card Specifications

A.3.2  TCC2P Card Specifications

A.3.3  AIC-I Card Specifications

A.3.4  AEP Specifications (ANSI only)

A.3.5  MIC-A/P FMEC Specifications (ETSI only)

A.3.6  MIC-C/T/P FMEC Specifications (ETSI only)

A.3.7  MS-ISC-100T Card Specifications

A.4  DWDM Card Specifications

A.4.1  OSCM Card Specifications

A.4.2  OSC-CSM Card Specifications

A.4.3  OPT-PRE Amplifier Card Specifications

A.4.4  OPT-BST Amplifier Card Specifications

A.4.5  OPT-BST-E Amplifier Card Specifications

A.4.6  OPT-BST-L Amplifier Card Specifications

A.4.7  OPT-AMP-L Preamplifier Card Specifications

A.4.8  32MUX-O Card Specifications

A.4.9  32DMX-O Card Specifications

A.4.10  32DMX Card Specifications

A.4.11  32DMX-L Card Specifications

A.4.12  4MD-xx.x Card Specifications

A.4.13  AD-1C-xx.x Card Specifications

A.4.14  AD-2C-xx.x Card Specifications

A.4.15  AD-4C-xx.x Card Specifications

A.4.16  AD-1B-xx.x Card Specifications

A.4.17  AD-4B-xx.x Card Specifications

A.4.18  32WSS Card Specifications

A.4.19  32WSS-L Card Specifications

A.4.20  MMU Card Specifications

A.5  Transponder and Muxponder Card Specifications

A.5.1  TXP_MR_10G Card Specifications

A.5.2  MXP_2.5G_10G Card Specifications

A.5.3  TXP_MR_2.5G and TXPP_MR_2.5G Card Specifications

A.5.4  MXP_MR_2.5G and MXPP_MR_2.5G Card Specifications

A.5.5  MXP_2.5G_10E Card Specifications

A.5.6  MXP_2.5G_10E_C Card Specifications

A.5.7  MXP_2.5G_10E_L Card Specifications

A.5.8  MXP_MR_10DME_C Card Specifications

A.5.9  MXP_MR_10DME_L Card Specifications

A.5.10  TXP_MR_10E Card Specifications

A.5.11  TXP_MR_10E_C Card Specifications

A.5.12  TXP_MR_10E_L Card Specifications

A.6  SFP Specifications

A.7  XFP Specifications


Hardware Specifications


This appendix contains hardware and software specifications for the ONS 15454 ANSI and ETSI shelf assemblies and cards.


Note Unless otherwise specified, "ONS 15454" refers to both ANSI and ETSI shelf assemblies.


The following sections are included:

Shelf Specifications

General Card Specifications

Common Control Card Specifications

DWDM Card Specifications

Transponder and Muxponder Card Specifications

SFP Specifications

XFP Specifications

A.1  Shelf Specifications

This section provides specifications for shelf bandwidth; a list of topologies; Cisco Transport Controller (CTC) specifications; the LAN, Transaction Language One (TL1), modem, and alarm specifications; timing, power, and environmental specifications; and shelf dimensions.

A.1.1  Bandwidth

The ONS 15454 has the following bandwidth specifications:

Total bandwidth: 240 Gbps

Data plane bandwidth: 160 Gbps

SONET/SDH plane bandwidth: 80 Gbps

A.1.2  Configurations

The ONS 15454 can be configured for the following dense wavelength division multiplexing (DWDM) topologies:

Hubbed rings

Multihubbed rings

Point-to-point

Linear

Linear with optical add/drop multiplexing (OADM)

Hybrid terminal node

Hybrid OADM node

Hybrid line amplifier node

A.1.3  Cisco Transport Controller

CTC, the ONS 15454 craft interface software, has the following specifications:

10BaseT Ethernet

TCC2/TCC2P card access: RJ-45 connector

Backplane access: LAN pin field (ANSI only)

Front Mount Electrical Connection (FMEC) access: LAN connector on MIC-C/T/P faceplate (ETSI only)

A.1.4  External LAN Interface

The ONS 15454 external LAN interface has the following specifications:

10BaseT Ethernet

Backplane access: LAN pin field (ANSI only)

FMEC access: LAN connector on MIC-C/T/P faceplate (ETSI only)

A.1.5  TL1 Craft Interface

The ONS 15454 TL1 craft interface has the following specifications:

Speed: 9600 bps

TCC2/TCC2P access: EIA/TIA-232 DB-9 type connector

Backplane access: CRAFT pin field (ANSI only)

A.1.6  Modem Interface

The ONS 15454 modem interface has the following specifications:

Hardware flow control

TCC2/TCC2P: EIA/TIA-232 DB-9 type connector

A.1.7  Alarm Interface

The ONS 15454 alarm interface has the following specifications:

ETSI

Visual: Critical, Major, Minor, Remote

Audible: Critical, Major, Minor, Remote

FMEC access: 62-Pin DB connector on MIC-A/P faceplate

Alarm inputs: Common 32-VDC output for all alarm-inputs, closed contact limited to 2 mA

Control outputs: Open contact maximum 60 VDC, closed contact maximum 100 mA

ANSI

Visual: Critical, Major, Minor, Remote

Audible: Critical, Major, Minor, Remote

Backplane access: Alarm pin fields

Alarm contacts: 0.045 mm, -48 V, 50 mA

A.1.8  EIA Interface (ANSI only)

The ONS 15454 electrical interface assembly (EIA) interface has the following specifications:

SMB: AMP #415504-3 75-ohm, 4-leg connectors

BNC: Trompeter #UCBJ224 75-ohm 4 leg connector (King or ITT are also compatible)

AMP Champ: AMP#552246-1 with #552562-2 bail locks

A.1.9  BITS Interface (ANSI only)

The ONS 15454 building integrated timing supply (BITS) interface has the following specifications:

2 DS-1 BITS inputs

2 derived DS-1 outputs

Backplane access: BITS pin field

A.1.10  System Timing

The ONS 15454 ANSI has the following system timing specifications:

Stratum 3 per Telcordia GR-253-CORE

Free running accuracy: +/- 4.6 ppm

Holdover stability: 3.7 x 10-7 per day, including temperature (< 255 slips in first 24 hours)

Reference: External BITS, line, internal

The ONS 15454 ETSI has the following system timing specifications:

Stratum 3E, per ITU-T G.813

Free running accuracy: +/- 4.6 ppm

Holdover stability: 3.7 exp -7 per day, including temperature (< 255 slips in first 24 hours)

Reference: External BITS, line, internal

A.1.11  System Power

The ONS 15454 ANSI has the following power specifications:

Input power: -48 VDC

Power consumption: Configuration dependent; 55 W (fan tray only)

Power requirements: -40.5 to -57 VDC

Power terminals: #6 Lug

ANSI shelf: 100-A fuse panel (minimum 30 A fuse per shelf)
HD shelf: 100-A fuse panel (minimum 30 A fuse per shelf)

The ONS 15454 ETSI has the following power specifications:

Input voltage: -48 VDC

Power consumption: Configuration dependent; 53 W (fan tray only)

Power requirements:

Nominal: -48 VDC

Tolerance limits: -40.5 to -57.0 VDC

Power terminals: 3WK3 Combo-D power cable connector (MIC-A/P and MIC-C/T/P faceplates)

Fusing: 100 A fuse panel; minimum 30 A fuse per shelf

A.1.12  System Environmental Specifications

The ONS 15454 ANSI has the following environmental specifications:

Operating temperature:

C-Temp: 32 to +131 degrees Farenheit (0 to +55 degrees Celsius)

I-Temp: -40 to +139 degrees Farenheit (-40 to +65 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

The ONS 15454 ETSI has the following environmental specifications:

Operating temperature: 32 to 104 degrees Fahrenheit (0 to +40 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

A.1.13  Dimensions

The ONS 15454 ANSI shelf assembly has the following dimensions:

Height: 18.5 in. (40.7 cm)

Width: 19 or 23 in. (41.8 or 50.6 cm) with mounting ears attached

Depth: 12 in. (26.4 cm) (5 in. or 12.7 cm projection from rack)

Weight: 55 lb (24.947 kg) empty

The ONS 15454 ETSI shelf assembly has the following dimensions:

Height: 616.5 mm (24.27 in.)

Width: 535 mm (17 in.) without mounting ears attached

Depth: 280 mm (11.02 in.)

Weight: 26 kg empty (57.3 lb)

A.2  General Card Specifications

This section provides power specifications and temperature ranges for all ONS 15454 cards.

A.2.1  Power

Table A-1 provides power consumption information for the ONS 15454 cards.

Table A-1 Individual Card Power Requirements 

Card Type
Card Name 
Watts
Amperes at -48 V
BTU/Hr.
Common Control Cards

TCC2/TCC2P

19.20

0.4

66.8

AIC-I

4.8

0.1

15.3

AEP

3

(from +5 VDC from AIC-I)

10.2

MIC-A/P

0.13

via TCC2/TCC2P

MIC-C/T/P

0.38

via TCC2/TCC2P

MS-ISC-100T

53

1.10

181.0

DWDM Cards

OSCM

Nominal 23

Maximum 26

Nominal 0.48

Maximum 0.54

Nominal 78.48

Maximum 88.71

OSC-CSM

Nominal 24

Maximum 27

Nominal 0.5

Maximum 0.56

Nominal 81.89

Maximum 92.12

OPT-PRE

Minimum 25

Nominal 30

Maximum39

Minimum 0.52

Nominal 0.5

Maximum 0.81

Minimum 85.3

Nominal 102.36

Maximum 88.71

OPT-BST

Nominal 30

Maximum 39

Nominal 0.63

Maximum 0.81

Nominal 102.36

Maximum 88.71

OPT-BST-E

Nominal 30

Maximum 39

Nominal 0.63

Maximum 0.81

Nominal 102.36

Maximum 88.71

OPT-BST-L

Nominal 25

Maximum 32

Nominal 0.52

Maximum 0.67

Nominal 85.30

Maximum 109.19

OPT-AMP-L

Nominal 32

Maximum 39.5

Nominal 0.67

Maximum 0.82

Nominal 109.19

Maximum 134.78

32MUX-O

Nominal 16

Maximum 25

Nominal 0.33

Maximum 0.52

Nominal 54.59

Maximum 85.3

32DMX-O

Nominal 16

Maximum 25

Nominal 0.33

Maximum 0.52

Nominal 54.59

Maximum 85.3

32DMX

Nominal 15

Maximum 25

Nominal 0.31

Maximum 0.52

Nominal 51.21

Maximum 85

DWDM Cards

32DMX-L

Nominal 15

Maximum 25

Nominal 0.31

Maximum 0.52

Nominal 51.21

Maximum 85

4MD-xx.x

Nominal 17

Maximum 25

Nominal 0.35

Maximum 0.52

Nominal 58.0

Maximum 85.3

AD-1C-xx.x

Nominal 17

Maximum 25

Nominal 0.35

Maximum 0.52

Nominal 58.0

Maximum 85.3

AD-2C-xx.x

Nominal 17

Maximum 25

Nominal 0.35

Maximum 0.52

Nominal 58.0

Maximum 85.3

AD-4C-xx.x

Nominal 17

Maximum 25

Nominal 0.35

Maximum 0.52

Nominal 58.0

Maximum 85.3

AD-1B-xx.x

Nominal 17

Maximum 25

Nominal 0.35

Maximum 0.52

Nominal 58.0

Maximum 85.3

AD-4B-xx.x

Nominal 17

Maximum 25

Nominal 0.35

Maximum 0.52

Nominal 58.0

Maximum 85.3

32WSS

Nominal 50

Maximum 65

Nominal 1.04

Maximum 1.35

Nominal 170

Maximum 221

32WSS-L

Nominal 43

Maximum 48

Nominal 0.90

Maximum 1.0

Nominal 146.72

Maximum 163.78

MMU

Nominal 7

Maximum 15

Nominal 0.15

Maximum 0.33

Nominal 24

Maximum 51

Transponder and Muxponder Cards

TXP_MR_10G

35.001

0.73

119.5

TXP_MR_10E

Nominal 40

Maximum 50

Nominal 1.11

Maximum 1.04

Nominal 136.6

Maximum 170.7

TXP_MR_10E_C

Nominal 40

Maximum 50

Nominal 1.11

Maximum 1.04

Nominal 136.6

Maximum 170.7

TXP_MR_10E_L

Nominal 40

Maximum 50

Nominal 1.11

Maximum 1.04

Nominal 136.6

Maximum 170.7

TXP_MR_2.5G

35.001

0.73

119.5

TXPP_MR_2.5G

501

1.04

170.5

MXP_2.5G_10G

501

1.04

170.7

MXP_2.5G_10E

Nominal 40

Maximum 50

Nominal 1.11

Maximum 1.04

Nominal 136.6

Maximum 170.7

MXP_2.5G_10E_C

Nominal 40

Maximum 50

Nominal 1.11

Maximum 1.04

Nominal 136.6

Maximum 170.7

MXP_2.5G_10E_L

Nominal 40

Maximum 50

Nominal 1.11

Maximum 1.04

Nominal 136.6

Maximum 170.7

Transponder and Muxponder Cards

MXP_MR_2.5G

Nominal 50

Maximum 60

Nominal 1.04

Maximum 1.25

Nominal 170.7

Maximum 204

MXPP_MR_2.5G

Nominal 50

Maximum 60

Nominal 1.04

Maximum 1.25

Nominal 170.7

Maximum 204

MXP_MR_10DME_C

Nominal 50

Maximum 60

Nominal 1.04

Maximum 1.25

Nominal 170.7

Maximum 204

MXP_MR_10DME_L

Nominal 50

Maximum 60

Nominal 1.04

Maximum 1.25

Nominal 170.7

Maximum 204

1 Calculated power; measured power was not available at the time of publication.


A.2.2  Temperature

Table A-2 provides temperature ranges and product names for ONS 15454 cards.


Note The I-Temp symbol is displayed on the faceplate of an I-Temp compliant card. A card without this symbol is C-Temp compliant.


Table A-2 Card Temperature Ranges and Product Names 

Card Type
Card Name
C-Temp Product Name
(32 to 131 degrees Fahrenheit, 0 to +55 degrees Celsius)
I-Temp Product Name
(-40 to 149 degrees Fahrenheit, -40 to +65 degrees Celsius)
Common Control Cards

TCC2/TCC2P

15454-TCC2/TCC2P

AIC-I

15454-AIC-I

AEP

15454-AEP

MIC-A/P

15454-MIC-A/P

MIC-C/T/P

15454 MIC-C/T/P

MS-ISC-100T

15454-MS-ISC

 
DWDM Cards

OSCM

15454-OSCM

OSC-CSM

15454-OSC-CSM

OPT-PRE

15454-OPT-PRE

OPT-BST

15454-OPT-BST

OPT-BST-E

15454-OPT-BST-E

OPT-BST-L

15454-OPT-BST-L

OPT-AMP-L

15454-OPT-AMP-L

32MUX-O

15454-32 MUX-O

32DMX-O

15454-32 DMX-O

32DMX

15454-32-DMX

32DMX-L

15454-32-DMX-L

4MD-xx.x

15454-4MD-xx.x

AD-1B-xx.x

15454-AD-1B-xx.x

AD-4B-xx.x

15454-AD-4B-xx.x

AD-1C-xx.x

15454-AD-1C-xx.x

AD-2C-xx.x

15454-AD-2C-xx.x

AD-4C-xx.x

15454-AD-4C-xx.x

32WSS

15454-WSS

32WSS-L

15454-WSS-L

MMU

15454-MMU

Transponder and Muxponder Cards

TXP_MR_10G

15454-TXPMR10G

TXP_MR_10E

15454-10EMRTXP

TXP_MR_10E_C

15454-10EMRC TXP

TXP_MR_10E_L

15454-10EMRL TXP

TXP_MR_2.5G

15454-2.5GMRTXP

TXPP_MR_2.5G

15454-2.5GMRTXP-P

MXP_2.5G_10G

15454-MXP2.5G10G

MXP_2.5G_10E

15454-4x2.5G10EMXP

MXP_2.5G_10E_C

15454-4x2.5G10EC MXP

MXP_2.5G_10E_L

15454-4x2.5G10ELMXP

MXP_MR_2.5G

15454-Datamux2.5GDM

MXPP_MR_2.5G

15454-Datamux2.5GDMP


A.3  Common Control Card Specifications

This section provides specifications for the TCC2, TCC2P, AIC, and AIC-I cards, the alarm expansion panel (AEP), the MIC-A/P and MIC-C/T/P FMECs, and the MS-ISC-100T card.

For compliance information, refer to the Cisco Optical Transport Products Safety and Compliance Information document.

A.3.1  TCC2 Card Specifications

The TCC2 card has the following specifications:

CTC software

Interface: EIA/TIA-232 (local craft access, on TCC2 faceplate)

Interface: 10BaseT LAN (on TCC2 faceplate)

Interface: 10BaseT LAN (through the backplane)

Synchronization

Stratum 3, per Telcordia GR-253-CORE

Free running access: Accuracy +/- 4.6 ppm

Holdover stability: 3.7 x 10-7 per day including temperature (< 255 slips in first 24 hours)

Reference: External BITS, line, internal

Supply voltage monitoring

Both supply voltage inputs are monitored.

Normal operation: -40.5 to -56.7 V

Undervoltage: Major alarm

Overvoltage: Major alarm

Environmental

Operating temperature: -40 to +149 degrees Fahrenheit (-40 to +65 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Power consumption: 26.00 W, 0.54 A at -48 V, 88.8 BTU/hr

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Depth with backplane connector: 235 mm (9.250 in.)

Weight not including clam shell: 0.7 kg (1.5 lb)

A.3.2  TCC2P Card Specifications

The TCC2P card has the following specifications:

CTC software

Interface: EIA/TIA-232 (local craft access, on TCC2P faceplate)

Interface: 10BaseT LAN (on TCC2P faceplate)

Interface: 10BaseT LAN (through the backplane)

Synchronization

Stratum 3, per Telcordia GR-253-CORE

Free running access: Accuracy +/- 4.6 ppm

Holdover stability: 3.7 * 10 exp - 7 per day including temperature (< 255 slips in first 24 hours)

Reference: External BITS, line, internal

Supply voltage monitoring

Both supply voltage inputs are monitored.

Normal operation: -40.5 to -56.7 V (in -48 VDC systems)

Undervoltage: Major alarm

Overvoltage: Major alarm

Environmental

Operating temperature: -40 to +149 degrees Fahrenheit (-40 to +65 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Power consumption: 26.00 W, 0.54 A at -48 V, 88.8 BTU/hr

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Depth with backplane connector: 9.250 in. (235 mm)

Weight not including clam shell: 1.5 lb (0.7 kg)

A.3.3  AIC-I Card Specifications

The AIC-I card has the following specifications:

Alarm inputs

Number of inputs: 12 without AEP, 32 with AEP

Opto-coupler isolated

Label customer provisionable

Severity customer provisionable

Common 32 V output for all alarm inputs

Each input limited to 2 mA

Termination: Wire-wrap on backplane without AEP, on AEP connectors with AEP

Alarm outputs

Number of outputs: 4 (user configurable as inputs) without AEP, 16 with AEP

Switched by opto MOS (metal oxide semiconductor)

Triggered by definable alarm condition

Maximum allowed open circuit voltage: 60 VDC

Maximum allowed closed circuit current: 100 mA

Termination: Wire-wrap on backplane without AEP, on AEP connectors with AEP

Express orderwire/local orderwire (EOW/LOW)

ITU-T G.711, ITU-T G.712, Telcordia GR-253-CORE

A-law, mu-law


Note Due to the nature of mixed coding, in a mixed-mode (A-law/mu-law) configuration, the orderwire is not ITU-T G.712 compliant.


Orderwire party line

Dual tone, multifrequency (DTMF) signaling

User data channel (UDC)

Bit rate: 64 kbps, codirectional

ITU-T G.703

Input/output impedance: 120 ohm

Termination: RJ-11 connectors

Data communications channel (DCC)

Bit rate: 576 kbps

EIA/TIA-485/V11

Input/output impedance: 120 ohm

Termination: RJ-45 connectors

ACC connection for additional alarm interfaces

Connection to AEP

Power monitoring alarming states:

Power failure (0 to -38 VDC)

Undervoltage (-38 to -40.5 VDC)

Overvoltage (beyond -56.7 VDC)

Environmental

Operating temperature: -40 to 149 degrees Fahrenheit (-40 to +65 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Power consumption (including AEP, if used): 8.00 W, 0.17 A, 27.3 BTU/hr

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Weight: 1.8 lb (0.82 kg)

A.3.4  AEP Specifications (ANSI only)

The AEP has the following specifications:

Alarm inputs

Number of inputs: 32

Optocoupler isolated

Label customer provisionable

Severity customer provisionable

Common 32 V output for all alarm inputs

Each input limited to 2 mA

Termination: 50-pin AMP champ connector

Alarm outputs

Number of outputs: 16

Switched by opto MOS

Triggered by definable alarm condition

Maximum allowed open circuit voltage: 60 VDC

Maximum allowed closed circuit current: 100 mA

Termination: 50-pin AMP champ connector

Environmental

Overvoltage protection: as in ITU-T G.703 Annex B

Operating temperature: -40 to +149 degrees Fahrenheit (-40 to +65 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Power consumption: 3.00 W max., from +5 VDC from AIC-I, 10.2 BTU/hr max.

Dimensions of AEP board

Height: 20 mm (0.79 in.)

Width: 330 mm (13.0 in.)

Depth: 89 mm (3.5 in.)

Weight: 0.18 kg (0.4 lb)

A.3.5  MIC-A/P FMEC Specifications (ETSI only)

The MIC-A/P FMEC card has the following specifications:

Power supply input BATTERY B

System supply voltage: Nominal -48 VDC
Tolerance limits: -40.5 to -57.0 VDC

Connector: 3WK3 Combo-D power cable connector

Alarm outputs

Voltage (open contact): Maximum 60 VDC

Current (closed contact): Maximum 250 mA

Connector: 62-pin DB connector (common for inputs/outputs)

Alarm inputs

Voltage (open contact): Maximum 60 VDC

Current (closed contact): Maximum 2 mA

Connector: 62-pin DB connector (common for inputs/outputs)

Environmental

Operating temperature: +23 to +113 degrees Fahrenheit (-5 to +45 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Power consumption: 0.13 W (provided by +5 V from the TCC2/TCC2P card), 0.44 BTU/hr

Dimensions

Height: 182 mm (7.165 in.)

Width: 32 mm (1.25 in.)

Depth: 92 mm (3.62 in.)

Depth with backplane connector: 98 mm (3.87 in.)

Weight not including clam shell: 0.2 kg (0.5 lb)

A.3.6  MIC-C/T/P FMEC Specifications (ETSI only)

The MIC-C/T/P FMEC card has the following specifications:

Power supply input BATTERY A

System supply voltage: Nominal -48 VDC
Tolerance limits: -40.5 to -57.0 VDC

Connector: 3WK3 Combo-D power cable connector

Timing connector

Frequency: 2.048 MHz +/-10 ppm

Signal level: 0.75 to 1.5 V

Impedance: 75 ohms +/-5 percent (switchable by jumper to high impedance > 3 kohms)


Note 120 ohms balanced impedance is possible with external matching cable.


Cable attenuation: Up to 6 dB at 2 MHz

Connectors: 1.0/2.3 miniature coax connector

System management serial port:

System management serial port craft interface

Modem port (for future use)

Connectors: 8-pin RJ-45

System management LAN port connectors:

Signal: IEEE 802.3 10BaseT

Connectors: 8-pin RJ-45

Environmental

Operating temperature: +23 to +113 degrees Fahrenheit (-5 to +45 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Power consumption: 0.38 W (provided by +5 V from the TCC2/TCC2P card), 1.37 BTU/hr

Dimensions

Height: 182 mm (7.165 in.)

Width: 32 mm (1.25 in.)

Depth: 92 mm (3.62 in.)

Depth with backplane connector: 98 mm (3.87 in.)

Weight not including clam shell: 0.2 kg (0.5 lb)

A.3.7  MS-ISC-100T Card Specifications

The MS-ISC-100T card has the following specifications:

Environmental

Operating temperature: +23 to +131 degrees Fahrenheit (-5 to +55 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Power consumption: 53.00 W, 1.10 A at -48 V, 181.0 BTU/hr

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Depth with backplane connector: 9.250 in. (235 mm)

Weight not including clam shell: 2.3 lb (1.0 kg)

A.4  DWDM Card Specifications

This section provides specifications for the OSCM, OSC-CSM, OPT-PRE amplifier, OPT-BST amplifier, OPT-BST-E amplifier, OPT-BST-L amplifier, OPT-AMP-L preamplifier (configurable as a preamplifier or booster amplifier), 32MUX-O, 32DMX-O, 32DMX, 32DMX-L, 4MD-xx.x, AD-IC-xx.x, AD-2C-xx.x, AD-4C-xx.x, AD-1B-xx.x, AD-4B-xx.x, 32WSS, 32WSS-L, and MMU cards.

For compliance information, refer to the Cisco Optical Transport Products Safety and Compliance Information document.

A.4.1  OSCM Card Specifications

The OSCM card has the following specifications:

Line

Bit rate: 155 Mbps

Code: Scrambled non-return to zero (NRZ)

Loopback modes: None

Connector: Duplex LC

Transmitter optical service channel (OSC) signal

Maximum transmitter output power: -1 dBm

Minimum transmitter output power: -5 dBm

Nominal wavelength: 1510-nm +/-10 nm

Variable optical attenuator (VOA) necessary in the transmit path to adjust the in-fiber optical power level

Receiver OSC signal

Maximum receiver level: -8 dBm at 10-10 bit error rate (BER)

Minimum receiver level: -40 dBm at 10-10 BER

Span budget: 40-dB span budget (about 150 km assuming fiber path loss equals 0.25 dB/km)

Jitter tolerance: Telcordia GR-253/G.823 compliant

Environmental

Operating temperature:

C-Temp: +23 to +131 degrees Fahrenheit (-5 to +55 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Dimensions

Height: 12.65 in. (321.3 mm)

Width: 0.92 in. (23.4 mm)

Depth: 9.00 in. (228.6 mm)

A.4.2  OSC-CSM Card Specifications

The OSC-CSM card has the following specifications:

Line

Bit rate: 155 Mbps

Code: Scrambled NRZ

Loopback modes: None

Connector: Duplex LC

Transmitter OSC signal

Maximum transmitter output power: -2 dBm

Minimum transmitter output power: -24 dBm

Nominal wavelength: 1510-nm +/-10 nm

VOA is necessary in the transmit path to adjust the in-fiber optical power level

Receiver OSC signal

Maximum receiver level: -8 dBm at 10-10 BER

Minimum receiver level: -40 dBm at 10-10 BER

Span loss budget: 35-dB span budget (approximately 140 km assuming that the fiber path loss is equal to 0.25 dB/km)

Jitter tolerance: Telcordia GR-253/G.823 compliant

Environmental

Operating temperature:

C-Temp: +23 to +131 degrees Fahrenheit (-5 to +55 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Dimensions

Height: 12.65 in. (321.3 mm)

Width: 0.92 in. (23.4 mm)

Depth: 9.00 in. (228.6 mm)

A.4.3  OPT-PRE Amplifier Card Specifications

The OPT-PRE amplifier card has the following specifications:

Optical characteristics:

Total operating wavelength range: 1530 to 1561.3 nm

Gain ripple (peak to valley): 1.5 dB

Mid-access loss (MAL) range (for dispersion compensation unit [DCU]): 3 to 9 dB

Gain range: 5 to 38.5 dBm in constant power mode, 5 to 28 dBm in constant gain mode

Minimum gain (standard range): 5.0 dBm

Maximum gain (standard range with programmable gain tilt): 21 dBm

Maximum gain (extended range with uncontrolled gain tilt): 38.5 dBm

Gain and power regulation over/undershoot: 0.5 dB

Limited maximum output power: 17.5 dBm

Maximum output power (with full channel load): 17 dB

Minimum output power (with one channel): -1 dBm

Input power (Pin) range at full channel load: -21.5 to 12 dBm

Input power (Pin) range at single channel load: -39.5 to -6 dBm

Noise figure at G3 21 dB = 6.5 dB

OSC filter drop (channels) insertion loss maximum: 1 dB

OSC filter drop (OSC) insertion loss maximum: 1.8 dB

OSC filter add (OSC) insertion loss maximum: 1.3 dB

Optical connectors: LC-UPC/2

Environmental

Operating temperature:

C-Temp: +23 to +131 degrees Fahrenheit (-5 to +55 degrees Celsius)

Operating humidity: 5 to 85 percent, noncondensing

Dimensions

Height: 12.65 in. (332 mm)

Width: 0.92 in. (24 mm)

Depth: 9.00 in. (240 mm)

A.4.4  OPT-BST Amplifier Card Specifications

The OPT-BST amplifier card has the following specifications:

Optical characteristics:

Total operating wavelength range: 1530 to 1561.3 nm

Gain ripple (peak to valley): 1.5 dB

Gain range: 5 to 20 dBm with programmable gain tilt

Gain and power regulation over/undershoot: 0.5 dB

Limited maximum output power: 17.5 dBm

Maximum output power (with full channel load): 17 dB

Minimum output power (with one channel): -1 dBm

Input power (Pin) range at full channel load: -3 to 12 dBm

Input power (Pin) range at single channel load: -21 to -6 dBm

Noise figure at G3 20 dB = 6 dB

OSC filter drop (channels) insertion loss maximum: 1 dB

OSC filter drop (OSC) insertion loss maximum: 1.8 dB

OSC filter add (OSC) insertion loss maximum: 1.3 dB

Optical connectors: LC-UPC/2

Environmental

Operating temperature:

C-Temp: +23 to +131 degrees Fahrenheit (-5 to +55 degrees Celsius)

Operating humidity: 5 to 85 percent, noncondensing

Dimensions

Height: 12.65 in. (332 mm)

Width: 0.92 in. (24 mm)

Depth: 9.00 in. (240 mm)

A.4.5  OPT-BST-E Amplifier Card Specifications

The OPT-BST-E amplifier card has the following specifications:

Optical characteristics:

Total operating wavelength range: 1530 to 1561.3 nm

Gain ripple (peak to valley): 1.8 dB

Gain range: 8 to 23 dB with programmable gain tilt

Extended gain range: 23 to 26 dB with gain tilt uncontrolled

Gain and power regulation over/undershoot: 0.5 dB

Limited maximum output power: 20.5 dBm

Maximum output power (with full channel load): 20 dB

Minimum output power (with one channel): -1 dBm

Input power (Pin) range at full channel load: -6 to 12 dBm

Input power (Pin) range at single channel load: -26 to -8 dBm

Noise figure at G3 23 dB = 6 dB

OSC filter drop (channels) insertion loss maximum: 1 dB

OSC filter drop (OSC) insertion loss maximum: 1.8 dB

OSC filter add (OSC) insertion loss maximum: 1.3 dB

Optical connectors: LC-UPC/2

Environmental

Operating temperature:

C-Temp: +23 to +131 degrees Fahrenheit (-5 to +55 degrees Celsius)

Operating humidity: 5 to 85 percent, noncondensing

Dimensions

Height: 12.65 in. (332 mm)

Width: 0.92 in. (24 mm)

Depth: 9.00 in. (240 mm)

A.4.6  OPT-BST-L Amplifier Card Specifications

The OPT-BST-L amplifier card has the following specifications:

Optical characteristics:

Total operating wavelength range: 1570.0 to 1605.0 nm

Gain ripple (peak to valley): 1.5 dB

Gain range: 8 to 20 dB with programmable gain tilt

Extended gain range: 20 to 27 dB with gain tilt uncontrolled

Gain and power regulation over/undershoot: 0.5 dB

Limited maximum output power: 10 dBm

Maximum output power (with full channel load): 17 dB

Minimum output power (with one channel): -10 dBm

Input power (Pin) range at full channel load: -10 to 9 dBm

Input power (Pin) range at single channel load: -37 to -18 dBm

Noise figure at G3 20 dB = 7.5 dB

Insertion loss (Line RX to OSC TX): 0.3 to 1.8 dB

Insertion loss (Line RX to COM TX): 0.3 to 1.0 dB

Insertion loss (OSC RX to LINE TX): 0.3 to 1.3 dB

Optical connectors: LC-UPC/2

Environmental

Operating temperature:

C-Temp: +23 to +131 degrees Fahrenheit (-5 to +55 degrees Celsius)

Operating humidity: 5 to 85 percent, noncondensing

Dimensions

Height: 12.65 in. (332 mm)

Width: 0.92 in. (24 mm)

Depth: 9.00 in. (240 mm)

A.4.7  OPT-AMP-L Preamplifier Card Specifications

The OPT-AMP-L card has the following specifications:

Optical characteristics:

DWDM channel wavelength plan, 100 GHz, 4 skip 1, ITU-T wavelength grid channels 71 (1602.3 nm) to 90 (1570.4 nm)

DWDM channel wavelength plan, 50 GHz, 8 skip 2, ITU-T wavelength grid channels 70.5 (1602.7 nm) to 90 (1570.4 nm)

Channel spacing: 100 and 50 GHz

Total operating wavelength range 1570.0 - 1605.0 nm

Gain ripple (peak to valley): 1.5 dB

Standard gain range: 12 to 24 dB

Extended gain range (uncontrolled gain tilt): 24 to 35 dB

Gain and power regulation over/undershoot: 0.5 dB

Maximum power output (standard or extended gain range): 20 dB

Input power range (full channel load): -15 to 8 dB

Input power range (single channel load): -40 to -17

Noise figure at G3 20 dB = 8.9 dB

Insertion loss (Line RX to OSC TX): 0.3 to 1.8 dB

Insertion loss (Line RX to COM TX): 0.3 to 1.0 dB

Insertion loss (OSC RX to LINE TX): 0.3 to 1.3 dB

Optical connectors: LC-UPC/2

Environmental

Operating temperature:

C-Temp: +23 to +131 degrees Fahrenheit (-5 to +55 degrees Celsius)

Operating humidity: 5 to 85 percent, noncondensing

Dimensions

Height: 12.65 in. (332 mm)

Width: 0.92 in. (24 mm)

Depth: 9.00 in. (240 mm)

A.4.8  32MUX-O Card Specifications

The 32MUX-O card optical specifications are listed in Table A-3.


Note For power specifications, refer to the "2.1.7  Multiplexer, Demultiplexer, and Optical Add/Drop Card Interface Classes" section on page 2-7.


Table A-3 32MUX-O Optical Specifications 

Parameter
Note
Condition
Min
Max
Unit

Transmit (Tx) filter shape (-1 dB bandwidth)

All standard operating procedures (SOP) and within whole operating temperature range

In 1/32—Out beginning of life (BOL)

+/-180

+/-300

pm

In 1/32—Out end of life (EOL)

+/-160

+/-300

pm

Insertion loss

All SOP and within whole operating temperature range

In 1/32—Out BOL

4

8.0

dB

In 1/32—Out EOL

4

8.5

dB

VOA dynamic range

25

dB

Optical monitor tap-splitting ratio on monitor port

Optical monitor port with respect to output port in multiplexer only

19

21

dB

Maximum optical input power

300

mW


The 32MUX-O card has the following additional specifications:

Environmental

Operating temperature:

C-Temp: +23 to +131 degrees Fahrenheit (-5 to +55 degrees Celsius)

Operating humidity: 5 to 95 percent relative humidity (RH)

Dimensions

Height: 12.65 in. (321.3 mm)

Width: 1.84 in. (46.8 mm)

Depth: 9.00 in. (228.6 mm)

A.4.9  32DMX-O Card Specifications

The 32DMX-O card optical specifications are listed in Table A-4.


Note For power specifications, see the "2.1.7  Multiplexer, Demultiplexer, and Optical Add/Drop Card Interface Classes" section on page 2-7.


Table A-4 32DMX-O Optical Specifications 

Parameter
Note
Condition
Min
Max
Unit

Receive (Rx) filter shape (-1 dB bandwidth)

All SOP and within whole operating temperature range

In 1/32—Out BOL

+/-180

+/-300

pm

In 1/32—Out EOL

+/-160

+/-300

pm

Insertion loss

All SOP and within whole operating temperature range

In 1/32—Out BOL

4

8.0

dB

In 1/32—Out EOL

4

8.5

dB

VOA dynamic range

25

dB

Maximum optical input power

300

mW


The 32DMX-O card has the following additional specifications:

Environmental

Operating temperature:

C-Temp: +23 to +131 degrees Fahrenheit (-5 to +55 degrees Celsius)

Operating humidity: 5 to 95 percent RH

Dimensions

Height: 12.65 in. (321.3 mm)

Width: 0.92 in. (23.4 mm)

Depth: 9.00 in. (228.6 mm)

A.4.10  32DMX Card Specifications

The 32DMX card optical specifications are listed in Table A-5.


Note For power specifications, see the "2.1.7  Multiplexer, Demultiplexer, and Optical Add/Drop Card Interface Classes" section on page 2-7.


Table A-5 32DMX Optical Specifications 

Parameter
Note
Condition
Min
Typical
Max
Units

-1 dB bandwidth

All SOP and within whole operating temperature range, connectors included, and for maximum VOA operating attenuation.

COM RX => TX 1, 32 (OUT)

+/-110

pm

-3 dB bandwidth

+/-200

pm

Insertion loss

All SOP, and within whole operating temperature range, connectors included.

COM RX => TX 1, 32

5.5

dB

VOA dynamic range

COM RX => TX 1, 32

25

dB

Maximum optical input power

300

mW


The 32DMX channel plan is shown in Table A-6. All 32DMX client interfaces must comply with this plan.

Table A-6 32DMX Channel Plan 

Channel Number
Band
Channel ID
Frequency (GHz)
Wavelength (nm)

1

1

30.3

195.9

1530.33

2

31.2

195.8

1531.12

3

31.9

195.7

1531.90

4

32.6

195.6

1532.68

5

2

34.2

195.4

1534.25

6

35.0

195.3

1535.04

7

35.8

195.2

1535.82

8

36.6

195.1

1536.61

9

3

38.1

194.9

1538.19

10

38.9

194.8

1538.98

11

39.7

194.7

1539.77

12

40.5

194.6

1540.56

13

4

42.1

194.4

1542.14

14

42.9

194.3

1542.94

15

43.7

194.2

1543.73

16

44.5

194.1

1544.53

17

5

46.1

193.9

1546.12

18

46.9

193.8

1546.92

19

47.7

193.7

1547.72

20

48.5

193.6

1548.51

21

6

50.1

193.4

1550.12

22

50.9

193.3

1550.92

23

51.7

193.2

1551.72

24

52.5

193.1

1552.52

25

7

54.1

192.9

1554.13

26

54.9

192.8

1554.94

27

55.7

192.7

1555.75

28

56.5

192.6

1556.55

29

8

58.1

192.4

1558.17

30

58.9

192.3

1558.98

31

59.7

192.2

1559.79

32

60.6

192.1

1560.61


The 32DMX card has the following additional specifications:

Environmental

Operating temperature:

C-Temp: +23 to +131 degrees Fahrenheit (-5 to +55 degrees Celsius)

Operating humidity: 5 to 95 percent RH

Dimensions

Height: 12.65 in. (321.3 mm)

Width: 0.92 in. (23.4 mm)

Depth: 9.00 in. (228.6 mm)

A.4.11  32DMX-L Card Specifications

The 32DMX-L card optical specifications are listed in Table A-5.


Note For power specifications, see the "2.1.7  Multiplexer, Demultiplexer, and Optical Add/Drop Card Interface Classes" section on page 2-7.


Table A-7 32DMX -L Optical Specifications 

Parameter
Note
Condition
Min
Typical
Max
Units

-1 dB bandwidth

All SOP and within whole operating temperature range, connectors included, and for maximum VOA operating attenuation.

COM RX => TX 1, 32 (OUT)

+/-100

pm

-3 dB bandwidth

+/-199

pm

Insertion loss

All SOP, and within whole operating temperature range, connectors included.

COM RX => TX 1, 32

5.8

dB

VOA dynamic range

COM RX => TX 1, 32

25

dB

Maximum optical input power

300

mW


The 32DMX-L channel plan is shown in Table A-8. All 32DMX-L client interfaces must comply with this plan.

Table A-8 32DMX-L Channel Plan  

Band ID
Channel Label
Frequency (THz)
Wavelength (nm)

B77.8

77.8

190

1577.86

78.6

189.9

1578.69

79.5

189.8

1579.52

80.3

189.7

1580.35

B81.1

81.1

189.6

1581.18

82.0

189.5

1582.02

82.8

189.4

1582.85

83.6

189.3

1583.69

B84.5

84.5

189.2

1584.53

85.3

189.1

1585.36

86.2

189

1586.20

87.0

188.9

1587.04

B87.8

87.8

188.8

1587.88

88.7

188.7

1588.73

89.5

188.6

1589.57

90.4

188.5

1590.41

B91.2

91.2

188.4

1591.26

92.1

188.3

1592.10

92.9

188.2

1592.95

93.7

188.1

1593.79

B94.6

94.6

188

1594.64

95.4

187.9

1595.49

96.3

187.8

1596.34

97.1

187.7

1597.19

B98.0

98.0

187.6

1598.04

98.8

187.5

1598.89

99.7

187.4

1599.75

00.6

187.3

1600.60

B01.4

01.4

187.2

1601.46

02.3

187.1

1602.31

03.1

187

1603.17

04.0

186.9

1604.03


The 32DMX-L card has the following additional specifications:

Environmental

Operating temperature:

C-Temp: +23 to +131 degrees Fahrenheit (-5 to +55 degrees Celsius)

Operating humidity: 5 to 95 percent RH

Dimensions

Height: 12.65 in. (321.3 mm)

Width: 0.92 in. (23.4 mm)

Depth: 9.00 in. (228.6 mm)

A.4.12  4MD-xx.x Card Specifications

The 4MD-xx.x card optical specifications are listed in Table A-9.


Note For power specifications, see the "2.1.7  Multiplexer, Demultiplexer, and Optical Add/Drop Card Interface Classes" section on page 2-7.


Table A-9 4MD-xx.x Optical Specifications 

Parameter
Note
Condition
Min
Max
Unit

Trx filter shape (-0.5 dB bandwidth TrxBW2)

All SOP and within whole operating temperature range

COM Rx—xx.xx Tx

COM Rx—yy.yy Tx

COM Rx—zz.zz Tx

COM Rx—kk.kk Tx

+/-180

pm

xx.xx Rx—COM Tx

yy.yy Rx—COM Tx

zz.zz Rx—COM Tx

kk.kk Rx—COM Tx

Insertion loss demultiplexer section

All SOP and within whole operating temperature range

COM Rx—xx.xx Tx

1.9

dB

COM Rx—yy.yy Tx

2.4

dB

COM Rx—zz.zz Tx

2.8

dB

COM Rx—kk.kk Tx

3.3

dB

Insertion loss multiplexer section

All SOP and within whole operating temperature range (two connectors included)

xx.xx Rx—COM Tx

3.6

dB

yy.yy Rx—COM Tx

3.2

dB

zz.zz Rx—COM Tx

3.0

dB

kk.kk Rx—COM Tx

2.6

dB

VOA dynamic range

25

dB

Maximum optical input power

300

mW


The 4MD-xx.x card has the following additional specifications:

Environmental

Operating temperature:

C-Temp: +23 to +131 degrees Fahrenheit (-5 to +55 degrees Celsius)

Operating humidity: 5 to 95 percent RH

Dimensions

Height: 12.65 in. (321.3 mm)

Width: 0.92 in. (23.4 mm)

Depth: 9.00 in. (228.6 mm)

A.4.13  AD-1C-xx.x Card Specifications

Table A-10 lists the AD-1C-xx.x optical specifications.

Table A-10 AD-1C-xx.x Card Optical Specifications 

Parameter
Note
Condition
Min
Max
Unit

Trx filter shape
(-0.5 dB bandwidth)
TrxBW2

All SOP and within whole operating temperature range

COM Rx—xx.xx Tx
xx.xx Rx—COM Tx

+/-180

pm

Rfx filter shape
(-0.5 dB bandwidth)
RfxBW2

All SOP and within whole operating temperature range

COM Rx—Exp Tx
Exp Rx—COM Tx

+/-180

pm

Insertion loss
(drop section)

All SOP and within whole operating temperature range (two connectors included)

COM Rx—xx.xx Tx

2.0

dB

Insertion loss
(express section)

VOA at minimum attenuation; all SOP and within whole operating temperature range (two connectors included)

COM Rx—Exp Tx
Exp Rx—COM Tx

2.4 or 1.2

dB

Insertion loss
(add section)

VOA at minimum attenuation; all SOP and within whole operating temperature range (two connectors included)

xx.xx Rx—COM Tx

2.6

dB

VOA dynamic range

30

dB

Maximum optical input power

300

mW


The AD-1C-xx.x card optical input and output power varies with amplifier output levels and the class of transponder interfaces used. See Table 2-3 on page 2-8 through Table 2-5 on page 2-9 for this information.

The AD-1C-xx.x card has the following additional specifications:

Environmental

Operating temperature:

C-Temp: +23 to +131 degrees Fahrenheit (-5 to +55 degrees Celsius)

Operating humidity: Telcordia GR-63 5.1.1.3 compliant; 5 to 95 percent RH

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.92 in. (23.4 mm)

Depth: 9.0 in. (228.6 mm)

A.4.14  AD-2C-xx.x Card Specifications

Table A-11 lists the AD-2C-xx.x optical specifications.

Table A-11 AD-2C-xx.x Card Optical Specifications 

Parameter
Note
Condition
Min
Max
Unit

Trx filter shape
(-0.5 dB bandwidth)
TrxBW2

All SOP and within whole operating temperature range

COM Rx—xx.xx Tx
COM Rx—yy.yy Tx

+/-180

pm

xx.xx Rx—COM Tx
yy.yy Rx—COM Tx

+/-180

Rfx filter shape
(-0.5 dB bandwidth)
RfxBW2

All SOP and within whole operating temperature range

COM Rx—Exp Tx
Exp Rx—COM Tx

+/-180

pm

Insertion loss
(drop section)

All SOP and within whole operating temperature range (two connectors included)

COM Rx—xx.xx Tx

2.0

dB

COM Rx—yy.yy Tx

2.4

dB

Insertion loss
(express section)

VOA at minimum attenuation; all SOP and within whole operating temperature range (two connectors included)

COM Rx—Exp Tx

2.7

dB

Exp Rx—COM Tx

1.6

dB

Insertion loss
(add section)

VOA at minimum attenuation; all SOP and within whole operating temperature range (two connectors included)

xx.xx Rx—COM Tx

3.1

dB

yy.yy Rx—COM Tx

2.7

dB

VOA dynamic range

30

dB

Maximum optical input power

300

mW


The AD-2C-xx.x card optical input and output power varies with amplifier output levels and the class of transponder interfaces used. See Table 2-3 on page 2-8 through Table 2-5 on page 2-9 for this information.

The AD-2C-xx.x has the following additional specifications:

Environmental

Operating temperature:

C-Temp: +23 to +131 degrees Fahrenheit (-5 to +55 degrees Celsius)

Operating humidity: Telcordia GR-63 5.1.1.3 compliant; 5 to 95 percent RH

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.92 in. (23.4 mm)

Depth: 9.0 in. (228.6 mm)

A.4.15  AD-4C-xx.x Card Specifications

Table A-12 lists the AD-4C-xx.x optical specifications.

Table A-12 AD-4C-xx.x Optical Specifications 

Parameter
Note
Condition
Min
Max
Unit

Channel grid

See Table A-13. The channel plan for the AD-4C-xx.x card is identical to the channel plan for the AD-1B-xx.x card.

Trx filter shape
(-0.5 dB bandwidth)
TrxBW2

All SOP and within whole operating temperature range

COM Rx—xx.xx Tx
COM Rxyy.yy Tx
COM Rx—zz.zz Tx
COM Rx—kk.kk Tx
xx.xx Rx—COM Tx
yy.yy Rx—COM Tx

+/-180

pm

Rfx filter shape
(-1 dB bandwidth)
RfxBW2

All SOP and within whole operating temperature range

COM Rx—Exp Tx
Exp Rx—COM Tx

pm

Insertion loss
(drop section)

All SOP and within whole operating temperature range (two connectors included)

COM Rx—xx.xx Tx

5.5

dB

COM Rx—yy.yy Tx

5.0

dB

COM Rx—zz.zz Tx

4.5

dB

COM Rx—kk.kk Tx

4.1

dB

Insertion loss
(express section)

VOA at minimum attenuation; all SOP and within whole operating temperature range (two connectors included)

COM Rx—Exp Tx

2.7

dB

Exp Rx—COM Tx

1.2

dB

Insertion loss
(add section)

VOA at minimum attenuation; all SOP and within whole operating temperature range (two connectors included)

xx.xx Rx—COM Tx

3.9

dB

yy.yy Rx—COM Tx

4.3

dB

zz.zz Rx—COM Tx

4.5

dB

kk.kk Rx—COM Tx

4.9

dB

VOA dynamic range

30

dB

Maximum optical input power

300

mW


The AD-4C-xx.x card optical input and output power varies with amplifier output levels and the class of transponder interfaces used. See Table 2-3 on page 2-8 through Table 2-5 on page 2-9 for this information.

The AD-4C-xx.x has the following additional specifications:

Environmental

Operating temperature:

C-Temp: +23 to +131 degrees Fahrenheit (-5 to +55 degrees Celsius)

Operating humidity: Telcordia GR-63 5.1.1.3 compliant; 5 to 95 percent RH

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.92 in. (23.4 mm)

Depth: 9.0 in. (228.6 mm)

A.4.16  AD-1B-xx.x Card Specifications

Table A-13 lists the unit names, band IDs, channel IDs, frequencies, and wavelengths assigned to the eight versions of the AD-1B-xx.x card.

Table A-13 AD-1B-xx.x Channel Allocation Plan by Band 

Unit Name
Band ID
Channel ID
Frequency (GHz)
Wavelength (nm)

AD-1B-30.3

B30.3

30.3

195.9

1530.33

30.7

195.85

1530.72

31.1

195.8

1531.12

31.5

195.75

1531.51

31.9

195.7

1531.90

32.2

195.65

1532.29

32.6

195.6

1532.68

33.3

195.55

1533.07

AD-1B-34.2

B34.2

34.2

195.4

1534.25

34.6

195.35

1534.64

35.0

195.3

1535.04

35.4

195.25

1535.43

35.8

195.2

1535.82

36.2

195.15

1536.22

36.6

195.1

1536.61

37.0

195.05

1537.00

AD-1B-38.1

B38.1

38.1

194.9

1538.19

38.5

194.85

1538.58

38.9

194.8

1538.98

39.3

194.75

1539.37

39.7

194.7

1539.77

40.1

194.65

1540.16

40.5

194.6

1540.56

40.9

194.55

1540.95

AD-1B-42.2

B42.1

42.1

194.4

1542.14

42.5

194.35

1542.54

42.9

194.3

1542.94

43.3

194.25

1543.33

43.7

194.2

1543.73

44.1

194.15

1544.13

44.5

194.1

1544.53

44.9

194.05

1544.92

AD-1B-46.1

B46.1

46.1

193.9

1546.12

46.5

193.85

1546.52

46.9

193.8

1546.92

47.3

193.75

1547.32

47.7

193.7

1547.72

48.1

193.65

1548.11

48.5

193.6

1548.51

48.9

193.55

1548.91

AD-1B-50.1

B50.1

50.1

193.4

1550.12

50.5

193.35

1550.52

50.9

193.3

1550.92

51.3

193.25

1551.32

51.7

193.2

1551.72

52.1

193.15

1552.12

52.5

193.1

1552.52

52.9

193.05

1552.93

AD-1B-54.1

B54.1

54.1

192.9

1554.13

54.5

192.85

1554.54

54.9

192.8

1554.94

55.3

192.75

1555.34

55.7

192.7

1555.75

56.1

192.65

1556.15

56.5

192.6

1556.96

56.9

192.55

1556.96

AD-1B-58.1

B58.1

58.1

192.4

1558.17

58.5

192.35

1558.58

58.9

192.3

1558.98

59.3

192.25

1559.39

59.7

192.2

1559.79

60.2

192.15

1560.20

60.6

192.1

1560.61

61.0

192.05

1561.01


Table A-14 lists AD-1B-xx.x optical specifications.

Table A-14 AD-1B-xx.x Optical Specifications 

Parameter
Note
Condition
Min
Max
Unit

-1 dB bandwidth

All SOP and within whole operating environmental range

COM Rx—Band Tx
Band Rx—COM Tx

3.6

nm

-1 dB bandwidth

All SOP and within whole operating temperature range

COM Rx—Exp Tx
Exp Rx—COM Tx

Refer to Table A-15.

nm

Insertion loss
(drop section)

All SOP and within whole operating environmental range; two connectors included, VOA set at minimum attenuation

COM Rx—Band Tx

3.0

dB

Insertion loss
(express section)

All SOP and within whole operating environmental range; two connectors included

Exp Rx—COM Tx

1.6

dB

All SOP and within whole operating environmental range; two connectors included, VOA set at its minimum attenuation

COM Rx—Exp Tx

2.2

dB

Insertion loss
(add section)

All SOP and within whole operating environmental range; two connectors included

Band Rx—COM Tx

2.2

dB

VOA dynamic range

30

dB

Maximum optical input power

300

mW


Table A-15 lists the range of wavelengths for the receive (express) band.

Table A-15 AD-1B-xx.x Transmit and Receive Dropped Band Wavelength Ranges 

Tx (Dropped) Band
Rx (Express) Band
Left Side (nm)
Right Side (nm)

B30.3

Wavelengths 1533.825 or higher

B34.2

Wavelengths 1533.395 or lower

Wavelengths 1537.765 or higher

B38.1

Wavelengths 1537.325 or lower

Wavelengths 1541.715 or higher

42.1

Wavelengths 1541.275 or lower

Wavelengths 1545.695 or higher

46.1

Wavelengths 1545.245 or lower

Wavelengths 1549.695 or higher

50.1

Wavelengths 1549.235 or lower

Wavelengths 1553.705 or higher

54.1

Wavelengths 1553.255 or lower

Wavelengths 1557.745 or higher

58.1

Wavelengths 1557.285 or lower


The AD-1B-xx.x card optical input and output power varies with amplifier output levels and the class of transponder interfaces used. See Table 2-3 on page 2-8 through Table 2-5 on page 2-9 for this information.

The AD-1B-xx.x card has the following additional specifications:

Environmental

Operating temperature:

C-Temp: +23 to +131 degrees Fahrenheit (-5 to +55 degrees Celsius)

Operating humidity: Telcordia GR-63 5.1.1.3 compliant; 5 to 95 percent RH

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.92 in. (23.4 mm)

Depth: 9.0 in. (228.6 mm)

A.4.17  AD-4B-xx.x Card Specifications

Table A-16 lists the unit names, band IDs, channel IDs, frequencies, and wavelengths assigned to the two versions of the card.

Table A-16 AD-4B-xx.x Channel Allocation Plan by Band 

Unit Name
Band ID
Channel ID
Frequency (GHz)
Wavelength (nm)

AD-4B-30.3

B30.3

30.3

195.9

1530.33

30.7

195.85

1530.72

31.1

195.8

1531.12

31.5

195.75

1531.51

31.9

195.7

1531.90

32.2

195.65

1532.29

32.6

195.6

1532.68

33.3

195.55

1533.07

B34.2

34.2

195.4

1534.25

34.6

195.35

1534.64

35.0

195.3

1535.04

35.4

195.25

1535.43

35.8

195.2

1535.82

36.2

195.15

1536.22

36.6

195.1

1536.61

37.0

195.05

1537.00

B38.1

38.1

194.9

1538.19

38.5

194.85

1538.58

38.9

194.8

1538.98

39.3

194.75

1539.37

39.7

194.7

1539.77

40.1

194.65

1540.16

40.5

194.6

1540.56

40.9

194.55

1540.95

B42.1

42.1

194.4

1542.14

42.5

194.35

1542.54

42.9

194.3

1542.94

43.3

194.25

1543.33

43.7

194.2

1543.73

44.1

194.15

1544.13

44.5

194.1

1544.53

44.9

194.05

1544.92

AD-4B-46.1

B46.1

46.1

193.9

1546.12

46.5

193.85

1546.52

46.9

193.8

1546.92

47.3

193.75

1547.32

47.7

193.7

1547.72

48.1

193.65

1548.11

48.5

193.6

1548.51

48.9

193.55

1548.91

B50.1

50.1

193.4

1550.12

50.5

193.35

1550.52

50.9

193.3

1550.92

51.3

193.25

1551.32

51.7

193.2

1551.72

52.1

193.15

1552.12

52.5

193.1

1552.52

52.9

193.05

1552.93

B54.1

54.1

192.9

1554.13

54.5

192.85

1554.54

54.9

192.8

1554.94

55.3

192.75

1555.34

55.7

192.7

1555.75

56.1

192.65

1556.15

56.5

192.6

1556.96

56.9

192.55

1556.96

B58.1

58.1

192.4

1558.17

58.5

192.35

1558.58

58.9

192.3

1558.98

59.3

192.25

1559.39

59.7

192.2

1559.79

60.2

192.15

1560.20

60.6

192.1

1560.61

61.0

192.05

1561.01


Table A-17 lists AD-4B-xx.x optical specifications.

Table A-17 AD-4B-xx.x Optical Specifications 

Parameter
Note
Condition
Min
Max
Unit

-1 dB bandwidth

All SOP and within whole operating environmental range

COM Rx—Band Tx
Band Rx—COM Tx

3.6

nm

-1 dB bandwidth

All SOP and within whole operating temperature range

COM Rx—Exp Tx
Exp Rx—COM Tx

Refer to Table A-18.

nm

Insertion loss
(drop section)

All SOP and within whole operating environmental range; two connectors included, VOA set at minimum attenuation

COM Rx—Band Tx
30.3/46.1

2.9

dB

COM Rx—Band Tx
34.2/50.1

3.3

dB

COM Rx—Band Tx
38.1/54.1

3.8

dB

COM Rx—Band Tx
42.1/58.1

4.5

dB

Insertion loss
(express section)

All SOP and within whole operating environmental range; two connectors included

Exp Rx—COM Tx

4.9

dB

All SOP and within whole operating environmental range; two connectors included, VOA set at its minimum attenuation

COM Rx—Exp Tx

3

dB

Insertion loss
(add section)

All SOP and within whole operating environmental range; two connectors included

Band Rx 30.3/46.1—COM Tx

3.5

dB

Band Rx 34.2/50.1—COM Tx

2.8

dB

Band Rx 38.1/54.1—COM Tx

2.3

dB

Band Rx 42.1/58.1—COM Tx

1.8

dB

VOA dynamic range

30

dB

Maximum optical input power

300

mW


Table A-18 lists the range of wavelengths for the receive (express) band.

Table A-18 AD-4B-xx.x Transmit and Receive Dropped Band Wavelength Ranges 

Tx (Dropped) Band
Rx (Express) Band
Left Side (nm)
Right Side (nm)

B30.3

Wavelengths 1533.825 or higher

B34.2

Wavelengths 1533.395 or lower

Wavelengths 1537.765 or higher

B38.1

Wavelengths 1537.325 or lower

Wavelengths 1541.715 or higher

B42.1

Wavelengths 1541.275 or lower

Wavelengths 1545.695 or higher

B46.1

Wavelengths 1545.245 or lower

Wavelengths 1549.695 or higher

B50.1

Wavelengths 1549.235 or lower

Wavelengths 1553.705 or higher

B54.1

Wavelengths 1553.255 or lower

Wavelengths 1557.745 or higher

B58.1

Wavelengths 1557.285 or lower


The AD-4B-xx.x card optical input and output power varies with amplifier output levels and the class of transponder interfaces used. See Table 2-3 on page 2-8 through Table 2-5 on page 2-9 for this information.

The AD-4B-xx.x has the following additional specifications:

Environmental

Operating temperature:

C-Temp: +23 to +131 degrees Fahrenheit (-5 to +55 degrees Celsius)

Operating humidity: Telcordia GR-63 5.1.1.3 compliant; 5 to 95 percent RH

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.92 in. (23.4 mm)

Depth: 9.0 in. (228.6 mm)

A.4.18  32WSS Card Specifications

The 32WSS card optical specifications are listed in Table A-19.


Note For power specifications, see the "2.1.7  Multiplexer, Demultiplexer, and Optical Add/Drop Card Interface Classes" section on page 2-7.


Table A-19 32WSS Optical Specifications 

Parameter
Note
Condition
Min
Typical
Max
Units

-0.25 dB bandwidth

All SOP and within whole operating temperature range, connectors included, and for maximum VOA operating attenuation.

EXP RX => COM TX

+/-/95

pm

-0.5 dB bandwidth

+/-115

pm

-1.0 dB bandwidth

+/-135

pm

-0.25 dB bandwidth

Add 1, 32 => COM TX

+/-115

pm

-0.5 dB bandwidth

+/-135

pm

-1.0 dB bandwidth

+/-160

pm

Insertion loss

All SOP, any optical switch state, and within whole operating temperature range, connectors included.

EXP RX => COM TX

11.3

dB

COM RX => EXP TX

1.5

dB

Add 1, 32 => COM TX

7.6

dB

COM RX => DROP TX

6

8.5

dB

VOA dynamic range

EXP RX => COM TX

20

dB

Add 1, 32 => COM TX

25

dB

Maximum optical input power

300

mW


The 32WSS channel plan is shown in Table A-20. All 32WSS client interfaces must comply with this plan.

Table A-20 32WSS Channel Plan 

Channel Number
Band
Channel ID
Frequency (GHz)
Wavelength (nm)

1

1

30.3

195.9

1530.33

2

31.2

195.8

1531.12

3

31.9

195.7

1531.90

4

32.6

195.6

1532.68

5

2

34.2

195.4

1534.25

6

35.0

195.3

1535.04

7

35.8

195.2

1535.82

8

36.6

195.1

1536.61

9

3

38.1

194.9

1538.19

10

38.9

194.8

1538.98

11

39.7

194.7

1539.77

12

40.5

194.6

1540.56

13

4

42.1

194.4

1542.14

14

42.9

194.3

1542.94

15

43.7

194.2

1543.73

16

44.5

194.1

1544.53

17

5

46.1

193.9

1546.12

18

46.9

193.8

1546.92

19

47.7

193.7

1547.72

20

48.5

193.6

1548.51

21

6

50.1

193.4

1550.12

22

50.9

193.3

1550.92

23

51.7

193.2

1551.72

24

52.5

193.1

1552.52

25

7

54.1

192.9

1554.13

26

54.9

192.8

1554.94

27

55.7

192.7

1555.75

28

56.5

192.6

1556.55

29

8

58.1

192.4

1558.17

30

58.9

192.3

1558.98

31

59.7

192.2

1559.79

32

60.6

192.1

1560.61


The 32WSS card has the following additional specifications:

Environmental

Operating temperature:

C-Temp: +23 to +131 degrees Fahrenheit (-5 to +55 degrees Celsius)

Operating humidity: 5 to 95 percent RH

Dimensions

Height: 12.65 in. (321.3 mm)

Width: 1.84 in. (46.8 mm)

Depth: 9.00 in. (228.6 mm)

A.4.19  32WSS-L Card Specifications

The 32WSS-L card optical specifications are listed in Table A-21.


Note For power specifications, see the "2.1.7  Multiplexer, Demultiplexer, and Optical Add/Drop Card Interface Classes" section on page 2-7.


Table A-21 32WSS-L Optical Specifications 

Parameter
Note
Condition
Min
Typical
Max
Units

-0.1 dB bandwidth

All SOP and within whole operating temperature range, connectors included, and for maximum VOA operating attenuation.

EXP RX => COM TX

+/-/57

pm

-0.25 dB bandwidth

+/-/61

+/-/89

-0.5 dB bandwidth

+/-91

+/-/116

-1.0 dB bandwidth

+/-135

+/-/149

-0.1 dB bandwidth

Add 1, 32 => COM TX

+/-32

+/-/69

-0.25 dB bandwidth

+/-98

+/-/129

-0.5 dB bandwidth

+/-135

+/-/161

-1.0 dB bandwidth

+/-160

+/-/201

Insertion loss

All SOP, any optical switch state, and within whole operating temperature range, connectors included.

EXP RX => COM TX

9.7

11.3

dB

COM RX => EXP TX

1.4

1.6

dB

Add 1, 32 => COM TX

6.2

8.0

dB

COM RX => DROP TX

6.0

8.0

8.5

dB

VOA dynamic range

EXP RX => COM TX

20

25

dB

Add 1, 32 => COM TX

25

25

dB

Maximum optical input power

300

mW


The 32WSS-L channel plan is shown in Table A-22. All 32WSS-L client interfaces must comply with this plan.

Table A-22 32WSS-L Channel Plan  

Band ID
Channel Label
Frequency (THz)
Wavelength (nm)

B77.8

77.8

190

1577.86

78.6

189.9

1578.69

79.5

189.8

1579.52

80.3

189.7

1580.35

B81.1

81.1

189.6

1581.18

82.0

189.5

1582.02

82.8

189.4

1582.85

83.6

189.3

1583.69

B84.5

84.5

189.2

1584.53

85.3

189.1

1585.36

86.2

189

1586.20

87.0

188.9

1587.04

B87.8

87.8

188.8

1587.88

88.7

188.7

1588.73

89.5

188.6

1589.57

90.4

188.5

1590.41

B91.2

91.2

188.4

1591.26

92.1

188.3

1592.10

92.9

188.2

1592.95

93.7

188.1

1593.79

B94.6

94.6

188

1594.64

95.4

187.9

1595.49

96.3

187.8

1596.34

97.1

187.7

1597.19

B98.0

98.0

187.6

1598.04

98.8

187.5

1598.89

99.7

187.4

1599.75

00.6

187.3

1600.60

B01.4

01.4

187.2

1601.46

02.3

187.1

1602.31

03.1

187

1603.17

04.0

186.9

1604.03


The 32WSS-L card has the following additional specifications:

Environmental

Operating temperature:

C-Temp: +23 to +131 degrees Fahrenheit (-5 to +55 degrees Celsius)

Operating humidity: 5 to 95 percent RH

Dimensions

Height: 12.65 in. (321.3 mm)

Width: 1.84 in. (46.8 mm)

Depth: 9.00 in. (228.6 mm)

A.4.20  MMU Card Specifications

The MMU card optical specifications are listed in Table A-23.


Note For power specifications, see the "2.1.7  Multiplexer, Demultiplexer, and Optical Add/Drop Card Interface Classes" section on page 2-7.


Table A-23 MMU Optical Specifications 

Parameter
Note
Condition
Min
Typical
Max
Units

Operating bandwidth

All SOP, any optical switch state, and within whole operating temperature range, connectors included.

All paths

1500

1605

nm

Insertion loss

All SOP, any optical switch state, and within whole operating temperature range, connectors included.

EXP RX => COM TX

7.0

dB

EXP A RX => COM TX

2.3

dB

COM RX => EXP TX

0.8

dB

COM RX => EXP A TX

14.8

dB

Wavelength dependent losses

All SOP, any optical switch state, and within whole operating temperature range, connectors included.

C-band only

0.3

dB

L-band only

0.3

dB

C and L bands

0.5

dB

Polarization dependent loss (PDL)

C-band only

0.2

dB

L-band only

0.2

dB

C and L bands

0.3

dB

Chromatic dispersion

 

All paths

-20

+20

ps/nm

Polarization mode dispersion (PMD)

All paths

0.1

ps

Optical power reading resolution

All photodiodes (both real and virtual)

0.1

dB

Optical power reading precision

-0.1

0.1

dB

Directivity

All SOP, any optical switch state, and within whole operating temperature range, connectors included.

EXP RX => EXP A RX

40

dB

EXP RX => EXP B RX

40

dB

EXP A RX => EXP B RX

40

dB

Return loss

40

dB

Maximum optical input power

Maximum handling power

500

mW


The MMU card has the following additional specifications:

Environmental

Operating temperature:

C-Temp: +23 to +131 degrees Fahrenheit (-5 to +55 degrees Celsius)

Operating humidity: 5 to 95 percent RH

Dimensions

Height: 12.65 in. (321.3 mm)

Width: 0.93 in. (23.6 mm)

Depth: 8.66 in. (220.1 mm)

A.5  Transponder and Muxponder Card Specifications

This section provides specifications for the TXP_MR_10G, MXP_2.5G_10G, TXP_MR_2.5G, TXPP_MR_2.5G, MXP_MR_2.5G, MXPP_MR_2.5G, MXP_2.5G_10E, MXP_2.5G_10E_C, MXP_2.5G_10E_E, TXP_MR_10E, TXP_MR_10E_C, TXP_MR_10E_L, MXP_MR_10DME_C, and MXP_MR_10DME_L cards.

For compliance information, refer to the Cisco Optical Transport Products Safety and Compliance Information document.

A.5.1  TXP_MR_10G Card Specifications

The TXP_MR_10G card has the following specifications:

Line (trunk side)

Bit rate:

9.95328 Gbps for OC-192/STM-64

10.70923 Gbps with ITU-T G.709 Digital Wrapper/forward error correction (FEC)

10.3125 Gbps for 10 Gigabit Ethernet (GE)

11.095 Gbps with ITU-T G.709 Digital Wrapper/FEC over 10 GE

Code: Scrambled NRZ

Fiber: 1550-nm single-mode

Maximum chromatic dispersion allowance: 1000 ps/nm

Loopback modes: Terminal and facility


Caution You must use a 15-dB fiber attenuator (10 to 20 dB) when working with the TXP_MR_10G card in a loopback on the trunk port. Do not use direct fiber loopbacks with the TXP_MR_10G card. Using direct fiber loopbacks causes irreparable damage to the TXP_MR_10G card.

Connectors: LC

Compliance Telcordia GR-253-CORE, ITU-T G.707, ITU-T G.691

Transmitter (trunk side)

Maximum transmitter output power: +3.5 dBm

Minimum transmitter output power: +2.5 dBm

Transmitter: Lithium Niobate (LN) external modulator transmitter

Wavelength stability (drift): +/- 25 picometers (pm)


Note An optical device on the card keeps the laser wavelength locked as closely as possible to the ITU nominal value. The allowed drift is +/- 25 pm.


Currently available wavelengths and versions of TXP_MR_10G (16 card versions, each covering two wavelengths):

1530.33 to 1531.12 nm (two wavelengths)

1531.90 to 1532.68 nm (two wavelengths)

1534.25 to 1535.04 nm (two wavelengths)

1535.82 to 1536.61 nm (two wavelengths)

1538.19 to 1538.98 nm (two wavelengths)

1539.77 to 1540.56 nm (two wavelengths)

1542.14 to 1542.94 nm (two wavelengths)

1543.73 to 1544.53 nm (two wavelengths)

1546.12 to 1546.92 nm (two wavelengths)

1547.72 to 1548.51 nm (two wavelengths)

1550.12 to 1550.92 nm (two wavelengths)

1551.72 to 1552.52 nm (two wavelengths)

1554.13 to 1554.94 nm (two wavelengths)

1555.75 to 1556.55 nm (two wavelengths)

1558.17 to 1558.98 nm (two wavelengths)

1559.79 to 1560.61 nm (two wavelengths)

Receiver (trunk side):

Receiver input power (no FEC, unamplified, 23 dB optical signal-to-noise ratio [OSNR], BER 1 * 10 exp - 12): -8 to -21 dBm

Receiver input power (no FEC, unamplified, 23 dB OSNR, at +/- 1000 ps/nm BER 1 * 10 exp - 12): -8 to -19 dBm

Receiver input power (no FEC, amplified, 19 dB OSNR, BER 1 * 10 exp - 12): -8 to -20 dBm

Receiver input power (no FEC, amplified, 19 dB OSNR, at +/- 1000 ps/nm BER 1 * 10 exp - 12):-8 to -18 dBm

Receiver input power (FEC, unamplified, 23 dB OSNR, BER 8 * 10 exp - 5): -8 to -24 dBm

Receiver input power (FEC, unamplified, 23 dB OSNR, at +/- 1000 ps/nm, BER 8 * 10 exp - 5): -8 to -22 dBm

Receiver input power (FEC, amplified, 9 dB OSNR, BER 8 * 10 exp - 5): -8 to -18 dBm

Receiver input power (FEC, unamplified, 11 dB OSNR, at +/- 800 ps/nm, BER 8 * 10 exp - 5): -8 to -18 dBm

Line (client side)

Bit rate: 9.95328 Gbps or 10.3125 Gbps

Code: Scrambled NRZ

Fiber: 1550-nm single-mode

Maximum chromatic dispersion allowance: Compliant with SR-1 specification for OC-192. In the case of 10 GE, the allowance is up to 10 km of single-mode fiber (SMF) dispersion.

Loopback modes: Terminal and facility

Connectors: LC

Transmitter (client side)

Maximum transmitter output power: -1 dBm

Minimum transmitter output power: -6 dBm

Center wavelength: 1290 to 1330 nm

Nominal wavelength: 1310 nm

Transmitter: Distributed feedback (DFB) laser

Receiver (client side)

Maximum receiver level: -1 dBm at BER 1 * 10 exp - 12

Minimum receiver level: -14 dBm at BER 1 * 10 exp - 12

Receiver: avalanche photodiode (APD)

Link loss budget: 8 dB minimum, at BER = 1 * 10 exp - 12

Receiver input wavelength range: 1290 to 1605 nm

Environmental

C-Temp: +23 to +131 degrees Fahrenheit (-5 to +55 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Power consumption: 35.00 W, 0.73 A at -48 V, 119.5 BTU/hr

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Depth with backplane connector: 9.250 in. (235 mm)

Weight not including clam shell: 3.1 lb (1.3 kg)

A.5.2  MXP_2.5G_10G Card Specifications

The MXP_2.5G_10G card has the following specifications:

Line (trunk side)

Bit rate:

9.95328 Gbps for OC-192/STM-64

10.70923 Gbps with ITU-T G.709 Digital Wrapper/FEC

Code: Scrambled NRZ

Fiber: 1550-nm single-mode

Maximum chromatic dispersion allowance: 1000 ps/nm

Loopback modes: Terminal and facility


Caution You must use a 20-dB fiber attenuator (15 to 25 dB) when working with the MXP_2.5G_10G card in a loopback on the trunk port. Do not use direct fiber loopbacks with the MXP_2.5G_10G card. Using direct fiber loopbacks causes irreparable damage to the MXP_2.5G_10G card.

Connectors: LC

Transmitter (trunk side)

Maximum transmitter output power: +3.5 dBm

Minimum transmitter output power: +2.5 dBm

Transmitter: LN external modulator transmitter

Wavelength stability (drift): +/- 25 picometers (pm)


Note An optical device on the card keeps the laser wavelength locked as closely as possible to the ITU nominal value. The allowed drift is +/- 25 pm.


Currently available wavelengths and versions of MXP_2.5G_10G (16 card versions, each covering two wavelengths):

1530.33 to 1531.12 nm (two wavelengths)

1531.90 to 1532.68 nm (two wavelengths)

1534.25 to 1535.04 nm (two wavelengths)

1535.82 to 1536.61 nm (two wavelengths)

1538.19 to 1538.98 nm (two wavelengths)

1539.77 to 1540.56 nm (two wavelengths)

1542.14 to 1542.94 nm (two wavelengths)

1543.73 to 1544.53 nm (two wavelengths)

1546.12 to 1546.92 nm (two wavelengths)

1547.72 to 1548.51 nm (two wavelengths)

1550.12 to 1550.92 nm (two wavelengths)

1551.72 to 1552.52 nm (two wavelengths)

1554.13 to 1554.94 nm (two wavelengths)

1555.75 to 1556.55 nm (two wavelengths)

1558.17 to 1558.98 nm (two wavelengths)

1559.79 to 1560.61 nm (two wavelengths)

Receiver (trunk side)

Receiver input power (no FEC, unamplified, 23 dB OSNR, BER 1 * 10 exp - 12): -8 to -21 dBm

Receiver input power (no FEC, unamplified, 23 dB OSNR, at +/- 1000 ps/nm BER 1 * 10 exp - 12): -8 to -19 dBm

Receiver input power (no FEC, amplified, 19 dB OSNR, BER 1 * 10 exp - 12): -8 to -20 dBm

Receiver input power (no FEC, amplified, 19 dB OSNR, at +/- 1000 ps/nm BER 1 * 10 exp - 12): -8 to -18 dBm

Receiver input power (FEC, unamplified, 23 dB OSNR, BER 8 * 10 exp - 5): -8 to -24 dBm

Receiver input power (FEC, unamplified, 23 dB OSNR, at +/- 1000 ps/nm, BER 8 * 10 exp - 5): -8 to -22 dBm

Receiver input power (FEC, amplified, 9 dB OSNR, BER 8 * 10 exp - 5): -8 to -18 dBm

Receiver input power (FEC, unamplified, 11 dB OSNR, at +/- 800 ps/nm, BER 8 * 10 exp - 5): -8 to -18 dBm

Line (client side)

Bit rate: 2.48832 Gbps

Code: Scrambled NRZ

Fiber: 1550-nm single-mode

Maximum chromatic dispersion allowance: Compliant with SR-1 specification for OC-192. In the case of 10 GE, allowance is up to 10 km of SMF fiber of dispersion.

Loopback modes: Terminal and facility

Connectors: LC

Transmitter (client side): Depends on the Small Form-factor Pluggable (SFP) that is used.

Receiver (client side): Depends on the SFP that is used.

Environmental

Operating temperature: +23 to +131 degrees Fahrenheit (-5 to +55 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Power consumption: 50.00 W, 1.04 A at -48 V, 170.7 BTU/hr

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Depth with backplane connector: 9.250 in. (235 mm)

Weight not including clam shell: 3.1 lb (1.3 kg)

A.5.3  TXP_MR_2.5G and TXPP_MR_2.5G Card Specifications

The TXP_MR_2.5G and TXPP_MR_2.5G cards have the following specifications:

Line (trunk side)

Bit rate:

2.488 Gbps for OC-48/STM-16

2.66 Gbps with ITU-T G.709 Digital Wrapper/FEC

Code: Scrambled NRZ

Fiber: 1550-nm single-mode

Maximum chromatic dispersion allowance: 5400 ps/nm

Loopback modes: Terminal and facility


Caution You must use a 20-dB fiber attenuator (15 to 25 dB) when working with the TXP_MR_2.5G and TXPP_MR_2.5G cards in a loopback on the trunk port. Do not use direct fiber loopbacks with the TXP_MR_2.5G and TXPP_MR_2.5G cards. Using direct fiber loopbacks causes irreparable damage to the TXP_MR_2.5G and TXPP_MR_2.5G cards.

Connectors: LC

Transmitter (trunk side)

Maximum transmitter output power: +1 dBm

Minimum transmitter output power: -4.5 dBm

Transmitter: Direct modulated laser

Wavelength stability (drift): +/- 25 picometers (pm)


Note An optical device on the card keeps the laser wavelength locked as closely as possible to the ITU nominal value. The allowed drift is +/- 25 pm.


Currently available wavelengths of TXP_MR_2.5G and TXPP_MR_2.5G (eight card versions):

ITU grid blue band: 1530.334 to 1544.526 nm (four card versions covering four wavelengths each)

ITU grid red band: 1546.119 to 1560.606 nm (four card versions covering four wavelengths each)

Receiver (trunk side, see Table A-24)

Table A-24 TXP_MR_2.5G/TXPP_MR_2.5G Card Receiver Trunk Side Specifications 

OSNR1
FEC Type
Pre-FEC BER
Post-FEC BER
Input Power Sensitivity
Chromatic Dispersion Tolerance

22 dB

Off - 2R

< 10 exp - 12

N/A

- 9 to - 24 dBm

22 dB

Off - 2R

< 10 exp - 12

N/A

- 9 to - 21 dBm

+/- 3300ps/nm

21 dB

Off - 3R

< 10 exp - 12

N/A

- 9 to - 30 dBm

22 dB

Off - 3R

< 10 exp - 12

N/A

- 9 to - 30 dBm

+/- 1800ps/nm

23 dB

Off - 3R

< 10 exp - 12

N/A

- 9 to - 30 dBm

+/- 5400ps/nm

12 dB

Standard- 3R

< 10 exp - 5

< 10 exp - 15

- 9 to - 25 dBm

12 dB

Standard- 3R

< 10 exp - 5

< 10 exp - 15

- 9 to - 24 dBm

+/- 1800ps/nm

12 dB

Standard- 3R

< 10 exp - 5

< 10 exp - 15

- 9 to - 23 dBm

+/- 5400ps/nm

21 dB

Standard- 3R

< 10 exp - 5

< 10 exp - 15

- 9 to - 31 dBm

1 OSNR defined with 0.1 nm resolution bandwidth (RBW)


Receiver: APD

Link loss budget: 24 dB minimum, with no dispersion or 22 dB optical path loss at
BER = 1 * 10 exp - 12 including dispersion

Line (client side)

Bit rate: 8 Mbps to 2.488 Gbps

Code: Scrambled NRZ

Fiber: Based on SFP (1310-nm single-mode or 850-nm multimode)

Maximum chromatic dispersion allowance: Based on SFP

Loopback modes: Terminal and facility

Connectors: LC

Transmitter (client side)

Maximum transmitter output power: -1 dBm

Minimum transmitter output power: -6 dBm

Center wavelength: Based on SFP

Nominal wavelength: Based on SFP

Transmitter: Based on SFP

Receiver (client side)

Maximum receiver level: -1 dBm at BER 1 * 10 exp - 12

Minimum receiver level: -14 dBm at BER 1 * 10 exp - 12

Receiver: APD

Link loss budget: 8 dB minimum, at BER = 1 * 10 exp - 12

Receiver input wavelength range: 850nm to 1605 nm

Environmental

Operating temperature: +23 to +113 degrees Fahrenheit (-5 to +45 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Power consumption: 35.00 W, 0.73 A at -48 V, 119.5 BTU/hr

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Depth with backplane connector: 9.250 in. (235 mm)

Weight not including clam shell: 3.1 lb (1.3 kg)

A.5.4  MXP_MR_2.5G and MXPP_MR_2.5G Card Specifications

The MXP_MR_2.5G and MXPP_MR_2.5G cards have the following specifications:

Payload configuration

FC1G—Fibre Channel 1.06 Gbps

FC2G—Fibre Channel 2.125 Gbps

FICON1G—Fiber connectivity 1.06 Gbps (IBM signal)

FICON2G—Fiber connectivity 2.125 Gbps (IBM signal)

ESCON—Enterprise System Connection 200 Mbps

ONE_GE—One Gigabit Ethernet 1.125 Gbps

Mixed configurations up to maximum line rate of 2.5 Gbps (for example, if you have a port configured for FC2G, you cannot use another port at the same time). See the "2.10.8  MXP_MR_2.5G and MXPP_MR_2.5G Cards" section on page 2-149 for more information on mixed-mode operation.

Client ports: 8x SFP

Performance monitoring (PM) for all interfaces

Buffer-to-buffer credit management for distance extension

Line (trunk side)

Bit rate: 2.488 Gbps for OC-48/STM-16

Code: Scrambled NRZ

Fiber: 1550-nm single-mode

Maximum chromatic dispersion allowance: 6000 ps/nm

Loopback modes: Terminal and facility


Caution You must use a 20-dB fiber attenuator (15 to 25 dB) when working with the MXP_MR_2.5G and MXPP_MR_2.5G cards in a loopback on the trunk port. Do not use direct fiber loopbacks with the MXP_MR_2.5G and MXPP_MR_2.5G cards. Using direct fiber loopbacks causes irreparable damage to the MXP_MR_2.5G and MXPP_MR_2.5G cards.

Connectors: LC

Transmitter (trunk side)

Transmit power: +3 +/- 1 dBm with MXP_MR_2.5G card, and +/- 1 dBm with MXPP_MR_2.5G card

50-GHz DWDM migration ready (the wavelength deviation is less than +/- 0.040 nm through wavelocker deployment)

Four-channel wavelength tunability at 100-GHz spacing

Transmitter maximum return reflectance: -27 dB

Chromatic dispersion allowance: 5400 ps/nm, giving an optical power penalty < 2.0 dB

Minimum side mode suppression ratio: 30 dB

Transmitter is a direct modulated laser

Wavelength stability (drift): +/- 25 picometers (pm)


Note An optical device on the card keeps the laser wavelength locked as closely as possible to the ITU nominal value. The allowed drift is +/- 25 pm.


Currently available wavelengths of the TXP_MR_2.5G and TXPP_MR_2.5G cards (eight card versions):

ITU grid blue band: 1530.334 to 1544.526 nm (four card versions, four wavelengths each)

ITU grid red band: 1546.119 to 1560.606 nm (four card versions, four wavelengths each)

Receiver (trunk side, see Table A-25)

Table A-25 MXP_MR_2.5G/MXPP_MR_2.5G Card Receiver Trunk Side Specifications 

OSNR1
FEC Type
Pre-FEC BER
Post-FEC BER
Input Power Sensitivity
Chromatic Dispersion Tolerance

17 dB

N/A

< 10 exp - 12

N/A

- 9 to - 23 dBm

17 dB

N/A

< 10 exp - 12

N/A

- 9 to - 22 dBm

+/- 1800 ps/nm

17 dB

N/A

< 10 exp - 12

N/A

- 9 to - 21 dBm

+/- 5400 ps/nm

18 dB

N/A

< 10 exp - 12

N/A

- 9 to - 23 dBm

+/- 1800 ps/nm

19 dB

N/A

< 10 exp - 12

N/A

- 9 to - 23 dBm

+/- 5400 ps/nm

21 dB

N/A

< 10 exp - 12

N/A

- 9 to - 30 dBm

21 dB

N/A

< 10 exp - 12

N/A

- 9 to - 29 dBm

+/- 1800 ps/nm

21 dB

N/A

< 10 exp - 12

N/A

- 9 to - 28 dBm

+/- 5400 ps/nm

22 dB

N/A

< 10 exp - 12

N/A

- 9 to - 30 dBm

+/- 1800 ps/nm

23 dB

N/A

< 10 exp - 12

N/A

- 9 to - 30 dBm

+/- 5400 ps/nm

1 OSNR defined with 0.1 nm RBW


Receiver sensitivity -28 dBm, BER 1 * 10 exp - 12

Receiver overload is equal to or exceeds -8 dBm

Receiver maximum reflectance of -27 dB

Line (client side)

Bit rate: 200Mbps or 1.06 Gbps to 2.125 Gbps per client

Code: Scrambled NRZ

Fiber: 1310-nm single-mode or 850-nm multimode

Maximum chromatic dispersion allowance: 1600 ps/nm

Loopback modes: Terminal and facility

Connectors: LC

Transmitter (client side)

Maximum transmitter output power: -1 dBm

Minimum transmitter output power: -6 dBm

Center wavelength: Based on SFP

Nominal wavelength: Based on SFP

Transmitter: Based on SFP

Receiver (client side)

Maximum receiver level: -1 dBm at BER 1 * 10 exp - 12

Minimum receiver level: -14 dBm at BER 1 * 10 exp - 12

Receiver: APD

Link loss budget: 8 dB minimum, at BER = 1 * 10 exp - 12

Receiver input wavelength range: 1290 to 1605 nm

Environmental

Operating temperature: +23 to +104 degrees Fahrenheit (-5 to +40 degrees Celsius)

Operating humidity: 5 to 85 percent, noncondensing

Power consumption (maximum): 60 W, 1.25 A at -48 V, 204 BTU/hr

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Depth with backplane connector: 9.250 in. (235 mm)

Weight not including clam shell: 2.25 lb (1.02 kg)

A.5.5  MXP_2.5G_10E Card Specifications

The MXP_2.5G_10E card has the following specifications:

Line (trunk side)

Bit rate: 10.70923 Gbps (in ITU-T G.709 Digital Wrapper/FEC mode)

Code: Scrambled NRZ

Fiber: 1550-nm single-mode

Maximum chromatic dispersion allowance: +/- 1200 ps/nm (specified penalty)

Loopback modes: Terminal and facility


Caution You must use a 20-dB fiber attenuator (15 to 25 dB) when working with the MXP_2.5G_10E card in a loopback on the trunk port. Do not use direct fiber loopbacks with the MXP_2.5G_10E card. Using direct fiber loopbacks causes irreparable damage to the MXP_2.5G_10E card.

Connectors: LC

Transmitter (trunk side)

Maximum transmitter output power: +6 dBm

Minimum transmitter output power: +3 dBm

Transmitter: LN external modulator transmitter

Wavelength stability (drift): +/- 25 picometers (pm)


Note An optical device on the card keeps the laser wavelength locked as closely as possible to the ITU nominal value. The allowed drift is +/- 25 pm.


Currently available wavelengths and versions of MXP_2.5G_10E (eight card versions):

ITU grid blue band:

1530.33 to 1533.07 nm (four channels)

1534.25 to 1537.00 nm (four channels)

1538.19 to 1540.95 nm (four channels)

1542.14 to 1544.92 nm (four channels)

ITU grid red band:

1546.12 to 1548.92 nm (four channels)

1550.12 to 1552.93 nm (four channels)

1554.13 to 1556.96 nm (four channels)

1558.17 to 1561.01 nm (four channels)

Receiver (trunk side, see Table A-26))

Receiver: APD

Link loss budget: 24 dB minimum, with no dispersion or 22 dB optical path loss at
BER = 1 * 10 exp - 12 including dispersion

Table A-26 MXP_2.5G_10E Card Receiver Trunk Side Specifications 

OSNR1
FEC Type
Pre-FEC BER
Post-FEC BER
Input Power Sensitivity2
Chromatic Dispersion Tolerance

30 dB

Off

< 10 exp - 12

N/A

- 8 to - 20 dBm

+/- 1200 ps/nm

26 dB

Off

< 10 exp - 12

N/A

- 8 to - 20 dBm

+/- 1000 ps/nm

26 dB

Off

< 10 exp - 12

N/A

- 8 to - 22 dBm

17 dB

Standard

< 10 exp - 5

< 10 exp - 15

- 8 to - 18 dBm

+/- 800 ps/nm

15 dB

Standard

< 10 exp - 5

< 10 exp - 15

- 8 to - 18 dBm

15 dB

Enhanced

< 7 x 10 exp - 4

< 10 exp - 15

- 8 to - 18 dBm

+/- 800 ps/nm

14 dB

Enhanced

< 7 x 10 exp - 4

< 10 exp - 15

- 8 to - 18 dBm

1 OSNR defined with 0.1 nm RBW

2 Receiver filter bandwidth greater than or equal to 180 pm (at - 3 dBm)


Line (client side)

Bit rate: 2.5 Gbps per port (OC-48/STM-16)

Code: Scrambled NRZ

Fiber: 1310-nm single-mode

Maximum chromatic dispersion allowance: 12 ps/nm (SR SFP version)

Loopback modes: Terminal and facility

Connectors: LC (optical)

Transmitter (client side): Depends on the SFP that is used.

Receiver (client side): Depends on the SFP that is used.

Environmental

Operating temperature: +23 to +113 degrees Fahrenheit (-5 to +55 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Power consumption: 50.00 W (maximum), 1.11 A at -48 V, 136.6 BTU/hr

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Depth with backplane connector: 9.250 in. (235 mm)

Weight not including clam shell: 3.1 lb (1.3 kg)

A.5.6  MXP_2.5G_10E_C Card Specifications

The MXP_2.5G_10E_C card has the following specifications:

Line (trunk side)

Bit rate: 10.70923 Gbps (in ITU-T G.709 Digital Wrapper/FEC mode)

Code: Scrambled NRZ

Fiber: 1550-nm single-mode

Maximum chromatic dispersion allowance: +/- 1200 ps/nm (specified penalty)

Loopback modes: Terminal and facility


Caution You must use a 20-dB fiber attenuator (15 to 25 dB) when working with the MXP_2.5G_10E_C card in a loopback on the trunk port. Do not use direct fiber loopbacks with the MXP_2.5G_10E_C card. Using direct fiber loopbacks causes irreparable damage to the card.

Connectors: LC

Transmitter (trunk side)

Maximum transmitter output power: +6 dBm

Minimum transmitter output power: +3 dBm

Transmitter: LN external modulator transmitter

Wavelength stability (drift): +/- 25 picometers (pm)


Note An optical device on the card keeps the laser wavelength locked as closely as possible to the ITU nominal value. The allowed drift is +/- 25 pm.


Currently available wavelengths and versions of MXP_2.5G_10E_C card:

There is a single version of the MXP_2.5G_10E_C card. It is tunable across 82 wavelengths in the C-band frequency plan, with channels on the ITU 50-GHz grid, as shown in Table A-27.

Table A-27 MXP_2.5G_10E_C Card Trunk Wavelengths 

Channel Number
Frequency (THz)
Wavelength (nm)
Channel Number
Frequency (THz)
Wavelength (nm)

1

196.00

1529.55

42

193.95

1545.72

2

195.95

1529.94

43

193.90

1546.119

3

195.90

1530.334

44

193.85

1546.518

4

195.85

1530.725

45

193.80

1546.917

5

195.80

1531.116

46

193.75

1547.316

6

195.75

1531.507

47

193.70

1547.715

7

195.70

1531.898

48

193.65

1548.115

8

195.65

1532.290

49

193.60

1548.515

9

195.60

1532.681

50

193.55

1548.915

10

195.55

1533.073

51

193.50

1549.32

11

195.50

1533.47

52

193.45

1549.71

12

195.45

1533.86

53

193.40

1550.116

13

195.40

1534.250

54

193.35

1550.517

14

195.35

1534.643

55

193.30

1550.918

15

195.30

1535.036

56

193.25

1551.319

16

195.25

1535.429

57

193.20

1551.721

17

195.20

1535.822

58

193.15

1552.122

18

195.15

1536.216

59

193.10

1552.524

19

195.10

1536.609

60

193.05

1552.926

20

195.05

1537.003

61

193.00

1553.33

21

195.00

1537.40

62

192.95

1553.73

22

194.95

1537.79

63

192.90

1554.134

23

194.90

1538.186

64

192.85

1554.537

24

194.85

1538.581

65

192.80

1554.940

25

194.80

1538.976

66

192.75

1555.343

26

194.75

1539.371

67

192.70

1555.747

27

194.70

1539.766

68

192.65

1556.151

28

194.65

1540.162

69

192.60

1556.555

29

194.60

1540.557

70

192.55

1556.959

30

194.55

1540.953

71

192.50

1557.36

31

194.50

1541.35

72

192.45

1557.77

32

194.45

1541.75

73

192.40

1558.173

33

194.40

1542.142

74

192.35

1558.578

34

194.35

1542.539

75

192.30

1558.983

35

194.30

1542.936

76

192.25

1559.389

36

194.25

1543.333

77

192.20

1559.794

37

194.20

1543.730

78

192.15

1560.200

38

194.15

1544.128

79

192.10

1560.606

39

194.10

1544.526

80

192.05

1561.013

40

194.05

1544.924

81

192.00

1561.42

41

194.00

1545.32

82

191.95

1561.83


Receiver (trunk side, see Table A-28)

Table A-28 MXP_2.5G_10E_C Card Receiver Trunk Side Specifications 

OSNR1
FEC Type
Pre-FEC BER
Post-FEC BER
Input Power Sensitivity2
Chromatic Dispersion Tolerance

30 dB

Off

< 10 exp - 12

N/A

- 8 to - 20 dBm

+/- 1200 ps/nm

26 dB

Off

< 10 exp - 12

N/A

- 8 to - 20 dBm

+/- 1000 ps/nm

26 dB

Off

< 10 exp - 12

N/A

- 8 to - 22 dBm

17 dB

Standard

< 10 exp - 5

< 10 exp - 15

- 8 to - 18 dBm

+/- 800 ps/nm

15.5 dB

Standard

< 10 exp - 5

< 10 exp - 15

- 8 to - 18 dBm

14 dB

Enhanced

< 7 x 10 exp - 4

< 10 exp - 15

- 8 to - 18 dBm

+/- 800 ps/nm

12 dB

Enhanced

< 7 x 10 exp - 4

< 10 exp - 15

- 8 to - 18 dBm

1 OSNR defined with 0.1 nm RBW

2 Receiver filter bandwidth greater than or equal to 180 pm (at - 3 dBm)


Receiver: APD

Link loss budget: 24 dB minimum, with no dispersion or 22 dB optical path loss at
BER = 1 * 10 exp - 12 including dispersion

Receiver input wavelength range: 1529 to 1562 nm

Line (client side)

Bit rate: 2.5 Gbps per port (OC-48/STM-16)

Code: Scrambled NRZ

Fiber: 1310-nm single-mode

Maximum chromatic dispersion allowance: 12 ps/nm (SR SFP version)

Loopback modes: Terminal and facility

Connectors: LC (optical)

Transmitter (client side): Depends on the SFP that is used.

Receiver (client side): Depends on the SFP that is used.

Environmental

Operating temperature: +23 to +113 degrees Fahrenheit (-5 to +55 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Power consumption: 50.00 W (maximum), 1.11 A at -48 V, 136.6 BTU/hr

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Depth with backplane connector: 9.250 in. (235 mm)

Weight not including clam shell: 3.1 lb (1.3 kg)

A.5.7  MXP_2.5G_10E_L Card Specifications

The MXP_2.5G_10E_L card has the following specifications:

Line (trunk side)

Bit rate: 10.70923 Gbps (in ITU-T G.709 Digital Wrapper/FEC mode)

Code: Scrambled NRZ

Fiber: 1550-nm single-mode

Maximum chromatic dispersion allowance: +/- 1200 ps/nm (specified penalty)

Loopback modes: Terminal and facility


Caution You must use a 20-dB fiber attenuator (15 to 25 dB) when working with the MXP_2.5G_10E_L card in a loopback on the trunk port. Do not use direct fiber loopbacks with the MXP_2.5G_10E_L card. Using direct fiber loopbacks causes irreparable damage to the card.

Connectors: LC

Transmitter (trunk side)

Maximum transmitter output power: +6 dBm

Minimum transmitter output power: +3 dBm

Transmitter: LN external modulator transmitter

Wavelength stability (drift): +/- 25 picometers (pm)


Note An optical device on the card keeps the laser wavelength locked as closely as possible to the ITU nominal value. The allowed drift is +/- 25 pm.


Currently available wavelengths and versions of MXP_2.5G_10E_L card:

There is a single version of the MXP_2.5G_10E_L card. It is tunable across 80 wavelengths in the L band frequency plan, with channels on the ITU 50-GHz grid, as shown in Table A-29.

Table A-29 MXP_2.5G_10E_L Card Trunk Wavelengths 

Channel Number
Frequency (THz)
Wavelength (nm)
Channel Number
Frequency (THz)
Wavelength (nm)

1

190.85

1570.83

41

188.85

1587.46

2

190.8

1571.24

42

188.8

1587.88

3

190.75

1571.65

43

188.75

1588.30

4

190.7

1572.06

44

188.7

1588.73

5

190.65

1572.48

45

188.65

1589.15

6

190.6

1572.89

46

188.6

1589.57

7

190.55

1573.30

47

188.55

1589.99

8

190.5

1573.71

48

188.5

1590.41

9

190.45

1574.13

49

188.45

1590.83

10

190.4

1574.54

50

188.4

1591.26

11

190.35

1574.95

51

188.35

1591.68

12

190.3

1575.37

52

188.3

1592.10

13

190.25

1575.78

53

188.25

1592.52

14

190.2

1576.20

54

188.2

1592.95

15

190.15

1576.61

55

188.15

1593.37

16

190.1

1577.03

56

188.1

1593.79

17

190.05

1577.44

57

188.05

1594.22

18

190

1577.86

58

188

1594.64

19

189.95

1578.27

59

187.95

1595.06

20

189.9

1578.69

60

187.9

1595.49

21

189.85

1579.10

61

187.85

1595.91

22

189.8

1579.52

62

187.8

1596.34

23

189.75

1579.93

63

187.75

1596.76

24

189.7

1580.35

64

187.7

1597.19

25

189.65

1580.77

65

187.65

1597.62

26

189.6

1581.18

66

187.6

1598.04

27

189.55

1581.60

67

187.55

1598.47

28

189.5

1582.02

68

187.5

1598.89

29

189.45

1582.44

69

187.45

1599.32

30

189.4

1582.85

70

187.4

1599.75

31

189.35

1583.27

71

187.35

1600.17

32

189.3

1583.69

72

187.3

1600.60

33

189.25

1584.11

73

187.25

1601.03

34

189.2

1584.53

74

187.2

1601.46

35

189.15

1584.95

75

187.15

1601.88

36

189.1

1585.36

76

187.1

1602.31

37

189.05

1585.78

77

187.05

1602.74

38

189

1586.20

78

187

1603.17

39

188.95

1586.62

79

186.95

1603.60

40

188.9

1587.04

80

186.9

1604.03


Receiver (trunk side, see Table A-30)

Table A-30 MXP_2.5G_10E_L Card Receiver Trunk Side Specifications 

OSNR1
FEC Type
Pre-FEC BER
Post-FEC BER
Input Power Sensitivity2
Chromatic Dispersion Tolerance

30 dB

Off

< 10 exp - 12

N/A

- 8 to - 20 dBm

+/- 1200 ps/nm

26 dB

Off

< 10 exp - 12

N/A

- 8 to - 20 dBm

+/- 1000 ps/nm

26 dB

Off

< 10 exp - 12

N/A

- 8 to - 22 dBm

17 dB

Standard

< 10 exp - 5

< 10 exp - 15

- 8 to - 18 dBm

+/- 800 ps/nm

15.5 dB

Standard

< 10 exp - 5

< 10 exp - 15

- 8 to - 18 dBm

15 dB

Enhanced

< 7 x 10 exp - 4

< 10 exp - 15

- 8 to - 18 dBm

+/- 800 ps/nm

13 dB

Enhanced

< 7 x 10 exp - 4

< 10 exp - 15

- 8 to - 18 dBm

1 OSNR defined with 0.1 nm RBW

2 Receiver filter bandwidth greater than or equal to 180 pm (at - 3 dBm)


Receiver: APD

Link loss budget: 24 dB minimum, with no dispersion or 22 dB optical path loss at
BER = 1 * 10 exp - 12 including dispersion

Receiver input wavelength range: 1570 to 1604 nm

Line (client side)

Bit rate: 2.5 Gbps per port (OC-48/STM-16)

Code: Scrambled NRZ

Fiber: 1310-nm single-mode

Maximum chromatic dispersion allowance: 12 ps/nm (SR SFP version)

Loopback modes: Terminal and facility

Connectors: LC (optical)

Transmitter (client side): Depends on the SFP that is used.

Receiver (client side): Depends on the SFP that is used.

Environmental

Operating temperature: +23 to +113 degrees Fahrenheit (-5 to +55 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Power consumption: 50.00 W (maximum), 1.11 A at -48 V, 136.6 BTU/hr

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Depth with backplane connector: 9.250 in. (235 mm)

Weight not including clam shell: 3.1 lb (1.3 kg)

A.5.8  MXP_MR_10DME_C Card Specifications

The MXP_MR_10DME_C card has the following specifications:

Payload configuration

FC1G—Fibre Channel 1.06 Gbps

FC2G—Fibre Channel 2.125 Gbps

FC4G—Fibre Channel 4.25 Gbps

FICON1G—Fiber connectivity 1.06 Gbps (IBM signal)

FICON2G—Fiber connectivity 2.125 Gbps (IBM signal)

FICON4G—Fiber connectivity 4.25 Gbps (IBM signal)

ONE_GE—One Gigabit Ethernet 1.125 Gbps

Mixed configurations up to maximum line rate of 10.0 Gbps. See the "2.10.9  MXP_MR_10DME_C and MXP_MR_10DME_L Cards" section on page 2-156 for more information on mixed-mode operation.

Client ports: 8x SFP

Line (trunk side)

Bit rate: 2.488 Gbps for OC-48/STM-16, 9.952 Gbps for OC-192/STM-64

Code: Scrambled NRZ

Fiber: 1550-nm single-mode

Loopback modes: Terminal and facility


Caution You must use a 20-dB fiber attenuator (15 to 25 dB) when working with the MXP_MR_10DME_C card in a loopback on the trunk port. Do not use direct fiber loopbacks with the MXP_MR_10DME_C cards. Using direct fiber loopbacks causes irreparable damage to the MXP_MR_10DME_C cards.

Connectors: LC

Transmitter (trunk side)

Minimum output power: +3 dBm

Maximum output power: +6 dBm

Minimum Single-Mode Suppression Ratio (SMSR): 30 dB

Minimum optical extinction ratio: 10 dB

41 wavelength tunability at 100-GHz spacing

Receiver maximum return reflectance (Rx return loss): -27 dB

Maximum chromatic dispersion allowance: +/- 1200 ps/nm (specified penalty)

Minimum side mode suppression ratio: 30 dB

Wavelength stability (drift): +/- 25 picometers (pm)


Note An optical device on the card keeps the laser wavelength locked as closely as possible to the ITU nominal value. The allowed drift is +/- 25 pm.


Currently available wavelengths for the MXP_MR_10DME_C card: See Table 2-90 on page 2-160

Receiver (trunk side, see Table A-31)

Table A-31 MXP_MR_10DME_C Card Receiver Trunk Side Specifications 

FEC Applications
OSNR1
Pre-FEC BER
Post-FEC BER
Input Power Sensitivity
Chromatic Dispersion Tolerance
Power Penalty
OSNR Penalty

None

23 dB

< 10 exp - 12

-8 to -20 dBm

+/- 1200 ps/nm

2 dBm

19 dB

< 10 exp - 12

-9 to -22 dBm

+/- 1000 ps/nm

2 dBm

FEC

10 dB

< 10 exp - 5

< 10 exp - 15

-8 to -18 dBm

+/- 800 ps/nm

1.5 dB

Enhanced FEC

19 dB

< 10 exp - 4

< 10 exp - 15

-8 to -26 dBm

+/- 800 ps/nm

2 dBm

2 dB

8 dB

< 10 exp - 4

< 10 exp - 15

-8 to -18 dBm

+/- 800 ps/nm

2 dBm

1.5 dB

1 OSNR defined with 0.5 nm RBW


Receiver: APD

Link loss budget: 24 dB minimum, with no dispersion or 22 dB optical path loss at
BER = 1 * 10 exp - 12 including dispersion

Receiver input wavelength range: 1529 to 1562 nm

Line (client side)

Bit rate: 1.06 Gbps to 4.25 Gbps per client

Code: Scrambled NRZ

Fiber: Based on SFP (1310-nm single-mode or 850-nm multimode)

Maximum chromatic dispersion allowance: Based on SFP

Loopback modes: Terminal and facility

Connectors: LC

Transmitter (client side)

Maximum transmitter output power: -1 dBm

Minimum transmitter output power: -6 dBm

Center wavelength: Based on SFP

Nominal wavelength: Based on SFP

Transmitter: Based on SFP

Receiver (client side)

Maximum receiver level: -1 dBm at BER 1 * 10 exp - 12

Minimum receiver level: -14 dBm at BER 1 * 10 exp - 12

Receiver: APD

Link loss budget: 8 dB minimum, at BER = 1 * 10 exp - 12

Receiver input wavelength range: 1290 to 1605 nm or 850nm

Environmental

Operating temperature: +23 to +104 degrees Fahrenheit (-5 to +40 degrees Celsius)

Operating humidity: 5 to 85 percent, noncondensing

Power consumption (maximum): 60 W, 1.25 A at -48 V, 204 BTU/hr

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Depth with backplane connector: 9.250 in. (235 mm)

Weight not including clam shell: 2.25 lb (1.02 kg)

A.5.9  MXP_MR_10DME_L Card Specifications

The MXP_MR_10DME_L card has the following specifications:

Payload configuration

FC1G—Fibre Channel 1.06 Gbps

FC2G—Fibre Channel 2.125 Gbps

FC4G—Fibre Channel 4.25 Gbps

FICON1G—Fiber connectivity 1.06 Gbps (IBM signal)

FICON2G—Fiber connectivity 2.125 Gbps (IBM signal)

FICON4G—Fiber connectivity 4.25 Gbps (IBM signal)

ONE_GE—One Gigabit Ethernet 1.125 Gbps

Mixed configurations up to maximum line rate of 10.0 Gbps. See the "2.10.9  MXP_MR_10DME_C and MXP_MR_10DME_L Cards" section on page 2-156 for more information on mixed-mode operation.

Client ports: 8x SFP

Line (trunk side)

Bit rate: 2.488 Gbps for OC-48/STM-16, 9.952 Gbps for OC-192/STM-64

Code: Scrambled NRZ

Fiber: 1550-nm single-mode

Loopback modes: Terminal and facility


Caution You must use a 20-dB fiber attenuator (15 to 25 dB) when working with the MXP_MR_10DME_L card in a loopback on the trunk port. Do not use direct fiber loopbacks with the MXP_MR_10DME_L cards. Using direct fiber loopbacks causes irreparable damage to the MXP_MR_10DME_L cards.

Connectors: LC

Transmitter (trunk side)

Minimum output power: +3 dBm

Maximum output power: +6 dBm

Minimum SMSR: 30 dB

Minimum optical extinction ratio: 10.5 dB

40 wavelength tunability at 100-GHz spacing, 80 wavelength tunability at 50-GHz spacing

Receiver maximum return reflectance (Rx return loss): -27 dB

Maximum chromatic dispersion allowance: +/- 1200 ps/nm (specified penalty)

Minimum side mode suppression ratio: 30 dB

Wavelength stability (drift): +/- 25 picometers (pm)


Note An optical device on the card keeps the laser wavelength locked as closely as possible to the ITU nominal value. The allowed drift is +/- 25 pm.


Currently available wavelengths for the MXP_MR_10DME_L card: See Table 2-90 on page 2-160

Receiver (trunk side, see Table A-32)

Table A-32 MXP_MR_10DME_L Card Receiver Trunk Side Specifications 

FEC Applications
OSNR1
Pre-FEC BER
Post-FEC BER
Input Power Sensitivity
Chromatic Dispersion Tolerance
Power Penalty
OSNR Penalty

None

23 dB

< 10 exp - 12

-8 to -19 dBm

+/- 1200 ps/nm

2 dBm

19 dB

< 10 exp - 12

-9 to -19 dBm

+/- 1000 ps/nm

2 dBm

FEC

10 dB

< 10 exp - 5

< 10 exp - 15

-8 to -18 dBm

+/- 800 ps/nm

1.5 dB

Enhanced FEC

19 dB

< 10 exp - 4

< 10 exp - 15

-8 to -26 dBm

+/- 800 ps/nm

2 dB

8 dB

< 10 exp - 4

< 10 exp - 15

-8 to -18 dBm

+/- 800 ps/nm

1.5 dB

1 OSNR defined with 0.5 nm RBW


Receiver: APD

Link loss budget: 24 dB minimum, with no dispersion or 22 dB optical path loss at
BER = 1 * 10 exp - 12 including dispersion

Receiver input wavelength range: 1570 to 1604 nm

Line (client side)

Bit rate: 1.06 Gbps to 4.25 Gbps per client

Code: Scrambled NRZ

Fiber: Based on SFP (1310-nm single-mode or 850-nm multimode)

Maximum chromatic dispersion allowance:Based on SFP

Loopback modes: Terminal and facility

Connectors: LC

Transmitter (client side)

Maximum transmitter output power: -1 dBm

Minimum transmitter output power: -6 dBm

Center wavelength: Based on SFP

Nominal wavelength: Based on SFP

Transmitter: Based on SFP

Receiver (client side)

Maximum receiver level: -1 dBm at BER 1 * 10 exp - 12

Minimum receiver level: -14 dBm at BER 1 * 10 exp - 12

Receiver: APD

Link loss budget: 8 dB minimum, at BER = 1 * 10 exp - 12

Receiver input wavelength range: 1290 to 1605 nm or 850 nm

Environmental

Operating temperature: +23 to +104 degrees Fahrenheit (-5 to +40 degrees Celsius)

Operating humidity: 5 to 85 percent, noncondensing

Power consumption (maximum): 60 W, 1.25 A at -48 V, 204 BTU/hr

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Depth with backplane connector: 9.250 in. (235 mm)

Weight not including clam shell: 2.25 lb (1.02 kg)

A.5.10  TXP_MR_10E Card Specifications

The TXP_MR_10E card has the following specifications:

Line (trunk side)

Bit rate: OC-192/STM-64 (9.95328 Gbps), OTU2 (10.70923 Gbps), 10GE (10.3125 Gbps), 10GE into OTU2 (non-standard 11.0957 Gbps), 10G FC (10.51875 Gbps), or 10G FC into OTU2 (non-standard 11.31764 Gbps)

Code: Scrambled NRZ

Fiber: 1550-nm single-mode

Maximum chromatic dispersion allowance: +/- 1200 ps/nm (specified penalty)

Loopback modes: Terminal and facility


Caution You must use a 15-dB fiber attenuator (10 to 20 dB) when working with the TXP_MR_10E card in a loopback on the trunk port. Do not use direct fiber loopbacks with the TXP_MR_10E card. Using direct fiber loopbacks causes irreparable damage to the TXP_MR_10E card.

Connectors: LC

Transmitter (trunk side)

Maximum transmitter output power: +6 dBm

Minimum transmitter output power: +3 dBm for C band and +2 dBm for L band

Transmitter: LN external modulator transmitter

Wavelength stability (drift): +/- 25 picometers (pm)


Note An optical device on the card keeps the laser wavelength locked as closely as possible to the ITU nominal value. The allowed drift is +/- 25 pm.


Currently available wavelengths and versions of TXP_MR_10E:

C-band frequency plan (eight card versions, each with four tunable channels on the ITU 100-GHz grid):

1530.33 to 1533.07 nm (four channels)

1534.25 to 1537.00 nm (four channels)

1538.19 to 1540.95 nm (four channels)

1542.14 to 1544.92 nm (four channels)

1546.12 to 1548.92 nm (four channels)

1550.12 to 1552.93 nm (four channels)

1554.13 to 1556.96 nm (four channels)

1558.17 to 1561.01 nm (four channels)

L-band frequency plan (five card versions, each with eight tunable channels on the ITU 50-GHz grid):

1577.44 to 1580.35 nm (eight channels)

1580.77 to 1583.69 nm (eight channels)

1584.11 to 1587.04 nm (eight channels)

1587.46 to 1590.41 nm (eight channels)

1590.83 to 1593.79 nm (eight channels)

Receiver (trunk side, see Table A-33)

Table A-33 TXP_MR_10E Card Receiver Trunk Side Specifications 

OSNR1
FEC Type
Pre-FEC BER
Post-FEC BER
Input Power Sensitivity2
Chromatic Dispersion Tolerance

30 dB

Off

< 10 exp - 12

N/A

- 8 to - 20 dBm

+/- 1200 ps/nm

26 dB

Off

< 10 exp - 12

N/A

- 8 to - 20 dBm

+ - 1000 ps/nm

26 dB

Off

< 10 exp - 12

N/A

- 8 to - 22 dBm

17 dB

Standard

< 10 exp - 5

< 10 exp - 15

- 8 to - 18 dBm

+/- 800 ps/nm

15 dB

Standard

< 10 exp - 5

< 10 exp - 15

- 8 to - 18 dBm

15 dB

Enhanced

< 7 x 10 exp - 4

< 10 exp - 15

- 8 to - 18 dBm

+/- 800 ps/nm

14 dB

Enhanced

< 7 x 10 exp - 4

< 10 exp - 15

- 8 to - 18 dBm

1 OSNR defined with 0.1 nm RBW

2 Receiver filter bandwidth greater than or equal to 180 pm (at - 3 dBm)


Receiver: APD

Link loss budget: 24 dB minimum, with no dispersion or 22 dB optical path loss at
BER = 1 * 10 exp - 12 including dispersion

Line (client side):

10-Gigabit Small Form-factor Pluggable (XFP)-based SR

Bit rate: 10GE (10.3125 Gbps), 10G FC (10.51875 Gbps), or STM-64/OC-192

Code: Scrambled NRZ

Fiber: 1310-nm single-mode

Maximum chromatic dispersion allowance: 6.6 ps/nm

Loopback modes: Terminal and facility

Connectors: LC

Compliance: Telcordia GR-253-CORE, ITU-T G.707, ITU-T G.957, ITU-T G.691

Transmitter (client side)

Maximum transmitter output power: -1 dBm

Minimum transmitter output power: -6 dBm

Center wavelength: 1290 to 1330 nm

Nominal wavelength: 1310 nm

Transmitter: DFB laser

Receiver (client side)

Maximum receiver level: -1 dBm at BER 1 * 10 exp - 12

Minimum receiver level: -14 dBm at BER 1 * 10 exp - 12

Receiver: APD

Link loss budget: 8 dB minimum, at BER = 1 * 10 exp - 12

Receiver input wavelength range: 1290 to 1605 nm

Environmental

Operating temperature: +23 to +113 degrees Fahrenheit (-5 to +55 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Power consumption: 50.00 W (maximum), 1.11 A at -48 V, 136.6 BTU/hr

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Depth with backplane connector: 9.250 in. (235 mm)

Weight not including clam shell: 3.1 lb (1.3 kg)

A.5.11  TXP_MR_10E_C Card Specifications

The TXP_MR_10E_C card has the following specifications:

Line (trunk side)

Bit rate: OC-192/STM-64 (9.95328 Gbps), OTU2 (10.70923 Gbps), 10GE (10.3125 Gbps), 10GE into OTU2 (non-standard 11.0957 Gbps), 10G FC (10.51875 Gbps), or 10G FC into OTU2 (non-standard 11.31764 Gbps)

Code: Scrambled NRZ

Fiber: 1550-nm single-mode

Maximum chromatic dispersion allowance: +/- 1200 ps/nm (specified penalty)

Loopback modes: Terminal and facility


Caution You must use a 15-dB fiber attenuator (10 to 20 dB) when working with the TXP_MR_10E_C card in a loopback on the trunk port. Do not use direct fiber loopbacks with the TXP_MR_10E_C card. Using direct fiber loopbacks causes irreparable damage to the TXP_MR_10E_C card.

Connectors: LC

Compliance: Telcordia GR-253-CORE, ITU-T G.707, ITU-T G.957, and ITU-T G.709

Transmitter (trunk side)

Maximum transmitter output power: +6 dBm

Minimum transmitter output power: +3 dBm

Transmitter: LN external modulator transmitter

Wavelength stability (drift): +/- 25 picometers (pm)


Note An optical device on the card keeps the laser wavelength locked as closely as possible to the ITU nominal value. The allowed drift is +/- 25 pm.


Currently available wavelengths and versions of TXP_MR_10E_C card:

There is a single version of the TXP_MR_10E_C card. It is tunable across 82 wavelengths in the C-band frequency plan, with channels on the ITU 50-GHz grid, as shown in Table A-34.

Table A-34 TXP_MR_10E_C Card Trunk Wavelengths 

Channel Number
Frequency (THz)
Wavelength (nm)
Channel Number
Frequency (THz)
Wavelength (nm)

1

196.00

1529.55

42

193.95

1545.72

2

195.95

1529.94

43

193.90

1546.119

3

195.90

1530.334

44

193.85

1546.518

4

195.85

1530.725

45

193.80

1546.917

5

195.80

1531.116

46

193.75

1547.316

6

195.75

1531.507

47

193.70

1547.715

7

195.70

1531.898

48

193.65

1548.115

8

195.65

1532.290

49

193.60

1548.515

9

195.60

1532.681

50

193.55

1548.915

10

195.55

1533.073

51

193.50

1549.32

11

195.50

1533.47

52

193.45

1549.71

12

195.45

1533.86

53

193.40

1550.116

13

195.40

1534.250

54

193.35

1550.517

14

195.35

1534.643

55

193.30

1550.918

15

195.30

1535.036

56

193.25

1551.319

16

195.25

1535.429

57

193.20

1551.721

17

195.20

1535.822

58

193.15

1552.122

18

195.15

1536.216

59

193.10

1552.524

19

195.10

1536.609

60

193.05

1552.926

20

195.05

1537.003

61

193.00

1553.33

21

195.00

1537.40

62

192.95

1553.73

22

194.95

1537.79

63

192.90

1554.134

23

194.90

1538.186

64

192.85

1554.537

24

194.85

1538.581

65

192.80

1554.940

25

194.80

1538.976

66

192.75

1555.343

26

194.75

1539.371

67

192.70

1555.747

27

194.70

1539.766

68

192.65

1556.151

28

194.65

1540.162

69

192.60

1556.555

29

194.60

1540.557

70

192.55

1556.959

30

194.55

1540.953

71

192.50

1557.36

31

194.50

1541.35

72

192.45

1557.77

32

194.45

1541.75

73

192.40

1558.173

33

194.40

1542.142

74

192.35

1558.578

34

194.35

1542.539

75

192.30

1558.983

35

194.30

1542.936

76

192.25

1559.389

36

194.25

1543.333

77

192.20

1559.794

37

194.20

1543.730

78

192.15

1560.200

38

194.15

1544.128

79

192.10

1560.606

39

194.10

1544.526

80

192.05

1561.013

40

194.05

1544.924

81

192.00

1561.42

41

194.00

1545.32

82

191.95

1561.83


Receiver (trunk side, see Table A-35)

Table A-35 TXP_MR_10E _C Card Receiver Trunk Side Specifications 

OSNR1
FEC Type
Pre-FEC BER
Post-FEC BER
Input Power Sensitivity2
Chromatic Dispersion Tolerance

30 dB

Off

< 10 exp - 12

N/A

- 8 to - 20 dBm

+/- 1200 ps/nm

26 dB

Off

< 10 exp - 12

N/A

- 8 to - 20 dBm

+ - 1000 ps/nm

26 dB

Off

< 10 exp - 12

N/A

- 8 to - 22 dBm

17 dB

Standard

< 10 exp - 5

< 10 exp - 15

- 8 to - 18 dBm

+/- 800 ps/nm

15.5 dB

Standard

< 10 exp - 5

< 10 exp - 15

- 8 to - 18 dBm

14 dB

Enhanced

< 7 x 10 exp - 4

< 10 exp - 15

- 8 to - 18 dBm

+/- 800 ps/nm

12 dB

Enhanced

< 7 x 10 exp - 4

< 10 exp - 15

- 8 to - 18 dBm

1 OSNR defined with 0.1 nm RBW

2 Receiver filter bandwidth greater than or equal to 180 pm (at - 3 dBm)


Receiver: APD

Link loss budget: 24 dB minimum, with no dispersion or 22 dB optical path loss at
BER = 1 * 10 exp - 12 including dispersion

Receiver input wavelength range: 1529 to 1562 nm

Line (client side):

XFP-based SR

Bit rate: 10GE (10.3125 Gbps), 10G FC (10.51875 Gbps), or STM-64/OC-192

Code: Scrambled NRZ

Fiber: 1310-nm single-mode

Maximum chromatic dispersion allowance: 6.6 ps/nm

Loopback modes: Terminal and facility

Connectors: LC

Transmitter (client side)

Maximum transmitter output power: -1 dBm

Minimum transmitter output power: -6 dBm

Center wavelength: 1290 to 1330 nm

Nominal wavelength: 1310 nm

Transmitter: DFB laser

Receiver (client side)

Maximum receiver level: -1 dBm at BER 1 * 10 exp - 12

Minimum receiver level: -14 dBm at BER 1 * 10 exp - 12

Receiver: APD

Link loss budget: 8 dB minimum, at BER = 1 * 10 exp - 12

Receiver input wavelength range: 1290 to 1605 nm

Environmental

Operating temperature: +23 to +113 degrees Fahrenheit (-5 to +55 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Power consumption: 50.00 W (maximum), 1.11 A at -48 V, 136.6 BTU/hr

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Depth with backplane connector: 9.250 in. (235 mm)

Weight not including clam shell: 3.1 lb (1.3 kg)

A.5.12  TXP_MR_10E_L Card Specifications

The TXP_MR_10E_L card has the following specifications:

Line (trunk side)

Bit rate: OC-192/STM-64 (9.95328 Gbps), OTU2 (10.70923 Gbps), 10GE (10.3125 Gbps), 10GE into OTU2 (non-standard 11.0957 Gbps), 10G FC (10.51875 Gbps), or 10G FC into OTU2 (non-standard 11.31764 Gbps)

Code: Scrambled NRZ

Fiber: 1550-nm single-mode

Maximum chromatic dispersion allowance: +/- 1200 ps/nm (specified penalty)

Loopback modes: Terminal and facility


Caution You must use a 15-dB fiber attenuator (10 to 20 dB) when working with the TXP_MR_10E_L card in a loopback on the trunk port. Do not use direct fiber loopbacks with the TXP_MR_10E_L card. Using direct fiber loopbacks causes irreparable damage to the TXP_MR_10E_L card.

Connectors: LC

Transmitter (trunk side)

Maximum transmitter output power: +6 dBm

Minimum transmitter output power: +2 dBm

Transmitter: LN external modulator transmitter

Wavelength stability (drift): +/- 25 picometers (pm)


Note An optical device on the card keeps the laser wavelength locked as closely as possible to the ITU nominal value. The allowed drift is +/- 25 pm.


Currently available wavelengths and versions of TXP_MR_10E_L card:

There is a single version of the TXP_MR_10E_L card. It is tunable across 80 wavelengths in the L band frequency plan, with channels on the ITU 50-GHz grid, as shown in Table A-36.

Table A-36 TXP_MR_10E_L Card Trunk Wavelengths 

Channel Number
Frequency (THz)
Wavelength (nm)
Channel Number
Frequency (THz)
Wavelength (nm)

1

190.85

1570.83

41

188.85

1587.46

2

190.8

1571.24

42

188.8

1587.88

3

190.75

1571.65

43

188.75

1588.30

4

190.7

1572.06

44

188.7

1588.73

5

190.65

1572.48

45

188.65

1589.15

6

190.6

1572.89

46

188.6

1589.57

7

190.55

1573.30

47

188.55

1589.99

8

190.5

1573.71

48

188.5

1590.41

9

190.45

1574.13

49

188.45

1590.83

10

190.4

1574.54

50

188.4

1591.26

11

190.35

1574.95

51

188.35

1591.68

12

190.3

1575.37

52

188.3

1592.10

13

190.25

1575.78

53

188.25

1592.52

14

190.2

1576.20

54

188.2

1592.95

15

190.15

1576.61

55

188.15

1593.37

16

190.1

1577.03

56

188.1

1593.79

17

190.05

1577.44

57

188.05

1594.22

18

190

1577.86

58

188

1594.64

19

189.95

1578.27

59

187.95

1595.06

20

189.9

1578.69

60

187.9

1595.49

21

189.85

1579.10

61

187.85

1595.91

22

189.8

1579.52

62

187.8

1596.34

23

189.75

1579.93

63

187.75

1596.76

24

189.7

1580.35

64

187.7

1597.19

25

189.65

1580.77

65

187.65

1597.62

26

189.6

1581.18

66

187.6

1598.04

27

189.55

1581.60

67

187.55

1598.47

28

189.5

1582.02

68

187.5

1598.89

29

189.45

1582.44

69

187.45

1599.32

30

189.4

1582.85

70

187.4

1599.75

31

189.35

1583.27

71

187.35

1600.17

32

189.3

1583.69

72

187.3

1600.60

33

189.25

1584.11

73

187.25

1601.03

34

189.2

1584.53

74

187.2

1601.46

35

189.15

1584.95

75

187.15

1601.88

36

189.1

1585.36

76

187.1

1602.31

37

189.05

1585.78

77

187.05

1602.74

38

189

1586.20

78

187

1603.17

39

188.95

1586.62

79

186.95

1603.60

40

188.9

1587.04

80

186.9

1604.03


Receiver (trunk side, see Table A-37)

Table A-37 TXP_MR_10E Card Receiver Trunk Side Specifications 

OSNR1
FEC Type
Pre-FEC BER
Post-FEC BER
Input Power Sensitivity2
Chromatic Dispersion Tolerance

30 dB

Off

< 10 exp - 12

N/A

- 8 to - 20 dBm

+/- 1200 ps/nm

26 dB

Off

< 10 exp - 12

N/A

- 8 to - 20 dBm

+ - 1000 ps/nm

26 dB

Off

< 10 exp - 12

N/A

- 8 to - 22 dBm

17 dB

Standard

< 10 exp - 5

< 10 exp - 15

- 8 to - 18 dBm

+/- 800 ps/nm

15.5 dB

Standard

< 10 exp - 5

< 10 exp - 15

- 8 to - 18 dBm

15 dB

Enhanced

< 7 x 10 exp - 4

< 10 exp - 15

- 8 to - 18 dBm

+/- 800 ps/nm

13 dB

Enhanced

< 7 x 10 exp - 4

< 10 exp - 15

- 8 to - 18 dBm

1 OSNR defined with 0.1 nm RBW

2 Receiver filter bandwidth greater than or equal to 180 pm (at - 3 dBm)


Receiver: APD

Link loss budget: 24 dB minimum, with no dispersion or 22 dB optical path loss at
BER = 1 * 10 exp - 12 including dispersion

Receiver input wavelength range: 1570 to 1604 nm

Line (client side):

XFP-based SR

Bit rate: 10GE (10.3125 Gbps), 10G FC (10.51875 Gbps), or STM-64/OC-192

Code: Scrambled NRZ

Fiber: 1310-nm single-mode

Maximum chromatic dispersion allowance: 6.6 ps/nm

Loopback modes: Terminal and facility

Connectors: LC

Transmitter (client side)

Maximum transmitter output power: -1 dBm

Minimum transmitter output power: -6 dBm

Center wavelength: 1290 to 1330 nm

Nominal wavelength: 1310 nm

Transmitter: DFB laser

Receiver (client side)

Maximum receiver level: -1 dBm at BER 1 * 10 exp - 12

Minimum receiver level: -14 dBm at BER 1 * 10 exp - 12

Receiver: APD

Link loss budget: 8 dB minimum, at BER = 1 * 10 exp - 12

Receiver input wavelength range: 1290 to 1605 nm

Environmental

Operating temperature: +23 to +113 degrees Fahrenheit (-5 to +55 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Power consumption: 50.00 W (maximum), 1.11 A at -48 V, 136.6 BTU/hr

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Depth with backplane connector: 9.250 in. (235 mm)

Weight not including clam shell: 3.1 lb (1.3 kg)

A.6  SFP Specifications

Table A-38 lists the specifications for available SFPs.

Table A-38 SFP Specifications 

SFP Product ID
Interface
Transmitter Output Power Min/Max (dBm)
Receiver Input Power Min/Max (dBm)

15454-SFP3-1-IR=

OC-3

-15 to -8

-23 to -8

15454E-SFP-L.1.1=

STM-1

-15 to -8

-34 to -10

15454-SFP12-4-IR=

OC-12, D1 Video

-15 to -8

-28 to -7

15454E-SFP-L.4.1=

STM-4, D1 Video

-15 to -8

-28 to -8

15454-SFP-OC48-IR=

OC-48, DV6000 (C-Cor)

-5 to +0

-18 to +0

ONS-SE-2G-S1=

OC-48, STM-16

-10 to -3

-18 to -3

15454E-SFP-L.16.1=

STM-16, DV6000 (C-Cor)

-5 to +0

-18 to 0

15454-SFP-200/
15454E-SFP-200

ESCON1

-8 to -4

-28 to -3

15454-SFP-GEFC-SX=/
15454E-SFP-GEFC-S=

Fibre Channel (1 and 2 Gbps), FICON2 , GE

-10 to -3.5

-17 to 0 (1FC and 1GE)

-15 to 0 (2FC)

15454-SFP-GE+-LX=/
15454E-SFP-GE+-LX=

Fibre Channel
(1 and 2 Gbps), FICON, GE, HDTV3

-9.5 to -3.0

-20 to -3 (1FC, 1GE, and 2FC)

ONS-SE-2G-L2

OC-48, STM-16

-2 to 3

-28 to -9

ONS-SE-200-MM=

ESCON

-20.5 to -15

-14 to -294

ONS-SE-G2F-SX=

Fibre Channel (1 and 2 Gbps), GE

-9.5 to 0 (GE)
-10 to -3.5 (1G and 2G FC/FICON)

-17 to 05 (GE)
-22 (1G FC/FICON)
-20 (2G FC/FICON)

ONS-SE-G2F-LX=

Fibre Channel (1 and 2 Gbps), FICON, GE, HDTV

-9.5 to -3 (GE)
-10 to -3.5 (1FC, 2FC, and FICON)

-19 to -36 (GE)
-22 (1G FC/FICON)
-21 (2G FC/FICON)

ONS-SC-GE-SX=

GE

-9.5 to 0

-17 to 05

ONS-SC-GE-LX=

GE

-9.5 to-3

-19 to -36

ONS-SE-4G-MM

Fibre Channel (4 Gbps)

-9.0 to -2.5

-15.0 min

ONS-SE-4G-SM

Fibre Channel (4 Gbps)

-8.4 to -3

-17 to -3

1 ESCON = Enterprise System Connection

2 FICON = fiber connectivity

3 HDTV = high-definition television

4 Based on any valid 8B/10B code pattern measured at, or extrapolated to, 10E-15 BER measured at center of eye

5 Minimum Stressed Sensitivity (10-12): -12.5(62.5um) and -13.5(50um) dBm

6 Minimum Stressed Sensitivity (10-12): -14.4 dBm


Table A-39 provides cabling specifications for the single-mode fiber (SMF) SFPs and Table A-40 provides cabling specifications for multimode fiber (MMF) SFPs. The SFP ports have LC-type connectors.

Table A-39 Single-Mode Fiber SFP Port Cabling Specifications 

SFP Product ID
Wavelength1
Fiber Type
Cable Distance

15454-SFP3-1-IR=
Intermediate Reach

1310 nm

9 micron SMF

15 km (9.3 miles)

15454E-SFP-L.1.1=
Short Haul

1310 nm

9 micron SMF

15 km (9.3 miles)

15454-SFP12-4-IR=
Intermediate Reach

1310 nm

9 micron SMF

15 km (9.3 miles)

15454E-SFP-L.4.1=
Short Haul

1310 nm

9 micron SMF

15 km (9.3 miles)

15454-SFP-OC48-IR=
Intermediate Reach

1310 nm

9 micron SMF

15 km (9.3 miles)

ONS-SE-2G-S1=
Short Reach

1310 nm

9 micron SMF

2 km (1.2 miles)

15454E-SFP-L.16.1=
Short Haul

1310 nm

9 micron SMF

15 km (9.3 miles)

15454-SFP-GE+-LX=/
15454E-SFP-GE+-LX=
Long Reach

1310 nm

9 micron SMF

10 km (6.2 miles) for FC 1G, FC 2G, and GE
5 km (3.1 miles) for HDTV

15454-SE-G2F-LX=
15454E-SE-G2F-LX=

1310 nm

9 micron SMF

10 km (6.2 miles) for FC 1G, FC 2G, and GE
5 km (3.1 miles) for HDTV

15454-SE-4G-SM=
15454E-SE-4G-SM=

1310 nm

9 micron SMF

20 km (12.4 miles)

1 Typical loss on a 1310 nm wavelength is 0.6 dB/km.


Table A-40 Multimode Fiber SFP Port Cabling Specifications 

SFP Product ID
Wavelength
Fiber Type
Cable Distance

15454-SFP-200/
15454E-SFP-200
Long Reach

1310 nm

62.5 micron MMF

2 km (1.2 miles)

15454-SFP-GEFC-SX/
15454E-SFP-GEFC-S
Short Reach

850 nm

62.5 micron MMF

300 m (984 ft) for FC 1 Gbps and 1.2 Gbps GE
150 m (492 ft) for FC 2 Gbps

50.0 micron MMF

550 m (1804 ft) for FC 1 Gbps and 1.2 Gbps GE
300 m (984 ft) for FC 2 Gbps

15454-SE-G2F-SX
15454E-SE-G2F-SX

850 nm

62.5 micron MMF

500 m (1640 ft) for FC 1 Gbps
300 m (984 ft) for FC 2 Gbps

15454-SE-4G-MM
15454E-SE-4G-MM

850 nm

62.5 micron MMF

150 m (492 ft)

50.0 micron MMF

70 m (230 ft)


A.7  XFP Specifications

Table A-41 lists the specifications for available XFPs.

Table A-41 XFP Specifications 

XFP Product ID
Interface
Transmitter Output Power Min/Max (dBm)
Receiver Input Power Min/Max (dBm)

ONS-XC-10G-S1

OC-192/STM64

10GE/10GFC

-6 to -1

-8.2 to +0.5

-11 to -1

-14.4 to +0.5

ONS-XC-10G-L21

OC-192/STM64

0 to +4

-24 to -7

1 When an ONS-XC-10G-L2 XFP is installed on a transponder card, that card must be installed in a high-speed slot (6, 7, 12, or 13).


Table A-42 provides cabling specifications for the SMF XFPs. The ports of the listed XFPs have LC-type connectors.

Table A-42 Single-Mode Fiber XFP Port Cabling Specifications 

XFP Product ID
Wavelength1
Fiber Type
Cable Distance

ONS-XC-10G-S1

1310 nm

SMF

10 km (6.2 miles) for 10GE/10GFC

2 km (1.2 miles) for OC-192/STM64

ONS-XC-10G-L22

1550 nm

SMF

80 km (49.7 miles) for OC-192/STM64

1 Typical loss on a 1310 nm wavelength is 0.6 dB/km.