Table 4 DWDM
DLT-FFP-<MOD2DWDMPAYLOAD>:[<TID>]:<SRC>,<DST>:<CTAG>[:::];
Deletes Y cable protection on client facilities.
|
DLT-LMP-CTRL:[<TID>]:<SRC>:<CTAG>;
Deletes an LMP control channel.
|
DLT-LMP-TLINK:[<TID>]:<SRC>:<CTAG>;
Deletes an LMP TE link
|
DLT-LMP-DLINK:[<TID>]:<SRC>:<CTAG>;
Deletes an LMP data link.
|
DLT-LNK:[<TID>]:<FROM>,<TO>:<CTAG>;
Deletes an optical link between two optical connection points.
|
DLT-OCHCC:[<TID>]:<AID>:<CTAG>[:::CKTID=<CKTID>],[CMDMDE=<CMDMDE>];
Deletes the OCH client connection.
|
DLT-OCHNC:[<TID>]:<SRC>,<DST>:<CTAG>:::[CKTID=<CKTID>], [CMDMDE=<CMDMDE>];
Deletes the OCH network connection.
|
DLT-OSC:[<TID>]:<AID>:<CTAG>;
Deletes the optical service channel (OSC) group of the NE.
|
DLT-WLEN:[<TID>]:<AID>:<CTAG>[:::CMDMDE=<CMDMDE>],[CKTID=<CKTID>];
Deletes the provisioned wavelength (WLEN).
|
ED-<MOD2DWDMPAYLOAD>:[<TID>]:<AID>:<CTAG>:::[NAME=<NAME>], [CMDMDE=<CMDMDE>],[FREQ=<FREQ>],[LOSSB=<LOSSB>]:[<PST>[,<SST>]]
Edits the operating parameters for an DWDM client facility.
|
ED-APC:[<TID>]::<CTAG>[:::APCENABLE=<APCENABLE>];
Modifies the amplification power control (APC) application attributes.
|
ED-FFP-<MOD2DWDMPAYLOAD>:[<TID>]:<AID>:<CTAG>:::[PROTID=<PROTID>], [RVRTV=<RVRTV>],[RVTM=<RVTM>],[PSDIRN=<PSDIRN>][:];
Edits a Y cable protection group on client facilities.
|
ED-FFP-OCH:[<TID>]:<AID>:<CTAG>:::[PROTID=<PROTID>],[RVRTV=<RVRTV>], [RVTM=<RVTM>],[PSDIRN=<PSDIRN>][:];
Edits the provisioning for the default protection group on the DWDM port of a TXP_MR_2.5G or TXPP_MR_2.5G card.
|
ED-LMP:[<TID>]::<CTAG>:::[ENABLED=<ENABLED>],[WDMEXT=<WDM>], [ROLE=<ROLE>], [LMPNODEID-<NODEID>][:];
Edits the global LMP protocol attributes.
|
ED-LMP-CTRL:[<TID>]:<SRC>:<CTAG>:::[LOCALPORT=<LOCALPORT>], [REMOTENE=<REMOTENE>],[REMOTEIP=<REMOTEIP>],[HELLO=<HELLO>],[HELLOMIN=<HELLOMIN>],[HELLOMAX=<HELLOMAX>],[DEAD=<DEAD>], [DEADMIN=<DEADMIN>], [DEADMAX=<DEADMAX>]:[<PST>][,<SST>];
Edits an LMP control channel.
|
ED-LMP-TLINK:[<TID>]:<SRC>:<CTAG>:::REMOTEID=<REMOTE_ID>, REMOTETE=<REMOTE_TELINK>, [MUXCAP=<MUXCAP>]:[<PST>[,<SST>]];
Edits an LMP TE link.
|
ED-LMP-DLINK:[<TID>]:<SRC>:<CTAG>:::[LINKTYPE=<LINKTYPE>],TELINK=<TELINK>,
REMOTEID=<REMOTEID>;
Edits an LMP data link.
|
ED-LNK:[<TID>]:<FROM>,<TO>:<CTAG>:::[CMDMDE=<CMDMDE>]: [<PST>[,<SST>]];
Edits an optical link.
|
ED-OCH:[<TID>]:<AID>:<CTAG>:::[RDIRN=<RDIRN>],[EXPWLEN=<EXPWLEN>], [VOAATTN=<VOAATTN>],[VOAPWR=<VOAPWR>],[CALOPWR=<CALOPWR>], [CHPOWER=<CHPOWER>],[NAME=<PORTNAME>],[SFBER=<SFBER>],[SDBER=<SDBER>], [COMM=<COMM>],[GCCRATE=<GCCRATE>],[OSDBER=<OSDBER>],[DWRAP=<DWRAP>], [FEC=<FEC>],[PAYLOADMAP=<PAYLOADMAP>],[MACADDR=<MACADDR>], [SYNCMSG=<SYNCMSG>],[SENDDUS=<SENDDUS>],[SOAK=<SOAK>],[OSPF=<OSPF>], [MFS=<MFS>],[CMDMDE=<CMDMDE>]:[<PST>[,<SST>]];
Edits the attributes (service parameters) and state of an optical channel (OCH) facility.
|
ED-OCHCC:[<TID>]:<AID>:<CTAG>[:::CKTID=<CKTID>], [CMDMDE=<CMDMDE>]:[<PST>[,<SST>]];
Edits the OCH client connection.
|
ED-OCHNC:[<TID>]:<SRC>,<DST>:<CTAG>:::[CKTID=<CKTID>], [CMDMDE=<CMDMDE>]:[<PST>[,<SST>]];
Edits the OCH network connection.
|
ED-OMS:[<TID>]:<AID>:<CTAG>:::[RDIRN=<RDIRN>],[EXPBAND=<EXPBAND>], [VOAATTN=<VOAATTN>],[VOAPWR=<VOAPWR>],[CALOPWR=<CALOPWR>], [CHPOWER=<CHPOWER>],[NAME=<NAME>],[SOAK=<SOAK>], [CMDMDE=<CMDMDE>]:[<PST>[,<SST>]];
Edits the attributes (service parameters) and state of an optical multiplex section (OMS) facility.
|
ED-OSC:[<TID>]:<AID>:<CTAG>:::[RINGID=<RINGID>,][NODEID=<NODEID>];
Edits the OSC group attributes.
|
ED-OTS:[<TID>]:<AID>:<CTAG>:::[RDIRN=<RDIRN>],[VOAATTN=<VOAATTN>], [VOAPWR=<VOAPWR>],[OFFSET=<OFFSET>],[CALTILT=<CALTILT>],[OSRI=<OSRI>], [AMPLMODE=<AMPLMODE>],[CHPOWER=<CHPOWER>],[EXPGAIN=<EXPGAIN>], [NAME=<NAME>],[SOAK=<SOAK>],[CMDMDE=<CMDMDE>]:[<PST>[,<SST>]];
Edits the attributes (service parameters) and state of an optical transport section (OTS) facility.
|
ED-SLV-WDMANS:[<TID>]:<AID>:<CTAG>:::[HIGHSLVEXP=<HIGHSLVEXP>], [LOWSLVEXP=<LOWSLVEXP>];
Edits the expected span loss verification.
|
ED-TRC-OCH:[<TID>]:<SRC>:<CTAG>:::[EXPTRC=<EXPTRC>],[TRC=<TRC>], [TRCMODE=<TRCMODE>],[TRCLEVEL=<TRCLEVEL>],[TRCFORMAT=<TRCFORMAT>][:];
Edits trace-related OCH facilities.
|
ED-WDMANS:[<TID>]:<AID>:<CTAG>:::[POWERIN=<POWERIN>], [POWEROUT=<POWEROUT>],[POWEREXP=<POWEREXP>],[NTWTYPE=<NTWTYPE>];
Edits the Automatic Optical Node Setup (AONS) application attributes.
|
ED-WLEN:[<TID>]:<AID>:<CTAG>:::[SIZE=<SIZE>],[CKTID=<CKTID>], [CMDMDE=<CMDMDE>]:[<PST>[,<SST>]];
Edits wavelength provisioning.
|
ENT-FFP-<MOD2DWDMPAYLOAD>:[<TID>]:<SRC>,<DST>:<CTAG>:::[PROTTYPE= <PROTTYPE>],[PROTID=<PROTID>],[RVRTV=<RVRTV>],[RVTM=<RVTM>], [PSDIRN=<PSDIRN>][:];
Creates Y cable protection on client facilities.
|
ENT-LMP-CTRL:[<TID>]:<SRC>:<CTAG>:::[LOCALPORT=<LOCALPORT>], [REMOTENE=<REMOTENE>],REMOTEIP=<REMOTEIP>,[HELLO=<HELLO>],[HELLOMIN=<HELLOMIN>],[HELLOMAX=<HELLOMAX>],[DEAD=<DEAD>],[DEADMIN=<DEADMIN>], [DEADMAX=<DEADMAX>]:[<PST>][,<SST>];
Creates an LMP control channel.
|
ENT-LMP-TLINK:[<TID>]:<SRC>:<CTAG>:::REMOTEID=<REMOTE_ID>, REMOTETE=<REMOTE_TELINK>, [MUXCAP=<MUXCAP>]:[<PST>[,<SST>]];
Creates an LMP TE link.
|
ENT-LMP-DLINK:[<TID>]:<SRC>:<CTAG>:::[LINKTYPE=<LINKTYPE>], TELINK=<TELINK>,REMOTEID=<REMOTEID>;
Creates an LMP data link.
|
ENT-LNK:[<TID>]:<FROM>,<TO>:<CTAG>::::[<PST>[,<SST>]];
Creates an optical link between two optical connection points.
|
ENT-OCHCC:[<TID>]:<AID>:<CTAG>[:::CKTID=<CKTID>], [CMDMDE=<CMDMDE>]:[<PST>][,<SST>];
Allocates an OCH client connection.
|
ENT-OCHNC:[<TID>]:<SRC>,<DST>:<CTAG>::[<WCT>]:[CKTID=<CKTID>], [CMDMDE=<CMDMDE>]:[<PST>[,<SST>]];
Allocates an OCH network connection.
|
ENT-OSC:[<TID>]:<AID>:<CTAG>:::[RINGID=<RINGID>],[NODEID=<NODEID>], [EAST=<EAST>],[WEST=<WEST>];
Creates the OSC group of the NE.
|
ENT-WLEN:[<TID>]:<AID>:<CTAG>::[<CCT>]:[SIZE=<SIZE>], [CKTID=<CKTID>]:[<PST>[,<SST>]];
Creates a wavelength.
|
OPR-APC:[<TID>]::<CTAG>[::::];
Permits the APC application inside the NE to force regulation of the optical power to the entire DWDM ring.
|
OPR-LASER-OTS:[<TID>]:<AID>:<CTAG>;
Instructs a laser to be switched on.
|
OPR-LNK:[<TID>]::<CTAG>;
Permits the optical link application inside the NE to calculate all the automatic optical links between end points which can be univocally identified by the NE.
|
OPR-PROTNSW-OCH:[<TID>]:<AID>:<CTAG>::<SW>;
Performs a protection switch on the trunk port of a TXPP_MR_2.5G card (protect version only).
|
OPR-SLV-WDMANS:[<TID>]:<AID>:<CTAG>;
Invokes the calculation of the expected span loss verification.
|
OPR-WDMANS:[<TID>]::<CTAG>;
Operates the AONS application inside the NE to force a recompute of the value to be assigned to all Variable Optical Attenuators (VOA) representing the optical path inside the node.
|
RLS-LASER-OTS:[<TID>]:<AID>:<CTAG>;
Instructs a laser to be switched off.
|
RLS-PROTNSW-<MOD2DWDMPAYLOAD>:[<TID>]:<SRC>:<CTAG>[::];
Releases a Y cable protection switch on client facilities.
|
RLS-PROTNSW-OCH:[<TID>]:<AID>:<CTAG>;
Performs a protection switch on the trunk port of a TXPP_MR_2.5G card.
|
RTRV-<MOD2DWDMPAYLOAD>:[<TID>]:<AID>:<CTAG>[::::];
Retrieves the configuration parameter of a DWDM client.
Output format:
SID DATE TIME M CTAG COMPLD "<AIDUNIONID>,<AIDTYPE>:,,[<ROLE>],[<STATUS>]:[NAME=<NAME>],[LBCL=<LBCL>], [OPT=<OPT>],[OPR=<OPR>],[FREQ=<FREQ>],[LOSSB=<LOSSB>]:<PSTPSTQ>,[<SST>]" ;
|
RTRV-ALMTH-<MOD2>:[<TID>]:<AID>:<CTAG>::[<CONDTYPE>][,,::];
Retrieves the alarm threshold values.
Output format:
SID DATE TIME M CTAG COMPLD "<AID>,<MOD>:<CONDTYPE>,,,<THLEVEL>" ;
|
RTRV-APC:[<TID>]::<CTAG>;
Retrieves the APC application attributes.
Output format:
SID DATE TIME M CTAG COMPLD "::[APCENABLE=<APCENABLE>,][APCSTATE=<APCSTATE>]" ;
|
RTRV-FFP-<MOD2DWDMPAYLOAD>:[<TID>]:<SRC>:<CTAG>[::::];
Retrieves Y cable protection on client facilities.
Output format:
SID DATE TIME M CTAG COMPLD "<AIDUNIONID>,<AIDUNIONID1>::[PROTTYPE=<PROTTYPE>],[PROTID=<PROTID>], [RVRTV=<RVRTV>],[RVTM=<RVTM>],[PSDIRN=<PSDIRN>]" ;
|
RTRV-FFP-OCH:[<TID>]:<AID>:<CTAG>[::::];
Retrieves the protection group information for the TXP_MR_2.5G and TXPP_MR_2.5G trunk port.
Output format:
SID DATE TIME M CTAG COMPLD "<WORK>,<PROTECT>::[PROTTYPE=<PROTTYPE>],[PROTID=<PROTID>], [RVRTV=<RVRTV>],[RVTM=<RVTM>],[PSDIRN=<PSDIRN>],[VRGRDTM=<VRGRDTM>], [DTGRDTM=<DTGRDTM>],[RCGRDTM=<RCGRDTM>],[OPOTYPE=<OPOTYPE>]" ;
|
RTRV-LMP:[<TID>]::<CTAG>;
Retrieves the global LMP protocol attributes.
Output format:
SID DATE TIME
M CTAG COMPLD
"::ENABLE=<ENABLE>,[WDM=<LOCALPORT>],[ROLE=<ROLE>],[NODEID=<NODEID>],
[OPSTATE=<OPSTATE>]"
;
|
RTRV-LMP-CTRL:[<TID>]:<SRC>:<CTAG>;
Retrieves an LMP control channel.
Output format:
SID DATE TIME M CTAG COMPLD "<AID>::REMOTEID=<REMOTEID>,LOCALPORT=<LOCALPORT>, REMOTEIP=<REMOTEIP>,[HELLO=<HELLO>],[HELLOMIN=<HELLOMIN>], [HELLOMAX=<HELLOMAX>],[DEAD=<DEAD>],[DEADMIN=<DEADMIN>], [DEADMAX=<DEADMAX>],[OPSTATE=<OPSTATE>]:[<PST>[,<SST>]] ;
|
RTRV-LMP-TLINK:[<TID>]:<SRC>:<CTAG>;
Retrieves an LMP TE link.
Output format:
SID DATE TIME M CTAG COMPLD "<SRC>::[REMOTEID=<REMOTEID>],[DWDM=<DWDM>],[REMOTETE=<REMOTETE>], [MUXCAP=<MUXCAP>],[OPSTATE=<OPSTATE>]:[<PST>[,<SST>]]" ;
|
RTRV-LMP-DLINK:[<TID>]:<SRC>:<CTAG>;
Retrieves an LMP data link.
Output format:
SID DATE TIME M CTAG COMPLD "<AID>::[LINKTYPE=<LINKTYPE>],[REMOTEID=<REMOTEID>],[TELINK=<TELINK>], [OPSTATE=<OPSTATE>]" ;
|
RTRV-LNK:[<TID>]::<CTAG>;
Retrieves all the optical links created in the NE.
Output format:
SID DATE TIME M CTAG COMPLD "<FROM>,<TO>::[OLNKT=<OLNKT>],[CTYPE=<CTYPE>],[RDIRN=<RDIRN>], [BAND=<BAND>],[WLEN=<WLEN>]:<PST_PSTQ>,[<SST>]" ;
|
RTRV-LNK-<MOD2O>:[<TID>]:<AID>:<CTAG>:::[OLNKT=<OLNKT>],[CTYPE=<CTYPE>], [RDIRN=<RDIRN>];
Retrieves any optical link associated with the entered AIDs or AID range.
Output format:
SID DATE TIME M CTAG COMPLD "<FROM>,<TO>::[OLNKT=<OPTICALLINKTYPE>],[CTYPE=<CREATIONTYPE>], [RDIRN=<RDIRN>],[BAND=<BAND>],[WLEN=<WLEN>]:<PST_PSTQ>,[<SST>]" ;
|
RTRV-NE-APC:[<TID>]:[<AID>]:<CTAG>;
Retrieves the APC application ports that are involved in node setup regulation.
Output format:
SID DATE TIME M CTAG COMPLD "<AID>,<MOD>::[MODIFDAT=<MODIFDAT>],[MODIFTM=<MODIFTM>], [CHECKDAT=<CHECKDAT>],[CHECKTM=<CHECKTM>]" ;
|
RTRV-NE-WDMANS:[<TID>]::<CTAG>;
Retrieves the optical nodes setup (WDMANS) application ports involved in node setup regulation.
Output format:
SID DATE TIME M CTAG COMPLD "[<AID>],<AIDTYPE>::[REGULATED=<REGULATED>],[PARAM=<PARAM>]" ;
|
RTRV-OCH:[<TID>]:<AID>:<CTAG>;
Retrieves the attributes (service parameters) and state of an OCH facility.
Output format:
SID DATE TIME M CTAG COMPLD "<AID>:,,[<ROLE>],[<STATUS>]:[RDIRN=<RDIRN>],[OPTYPE=<OPTICALPORTTYPE>], [OPWR=<POWER>],[EXPWLEN=<EXPWLEN>],[ACTWLEN=<ACTWLEN>], [ILOSS=<ILOSS>],[VOAMODE=<VOAMODE>],[VOAATTN=<VOAATTN>], [VOAPWR=<VOAPWR>],[VOAREFATTN=<VOAREFATTN>], [VOAREFPWR=<VOAREFPWR>],[REFOPWR=<REFOPWR>],[CALOPWR=<CALOPWR>], [CHPOWER=<CHPOWER>],[NAME=<PORTNAME>],[SFBER=<SFBER>],[SDBER=<SDBER>], [COMM=<COMM>],[GCCRATE=<GCCRATE>],[DWRAP=<DWRAP>],[FEC=<FEC>], [PAYLOADMAP=<PAYLOADMAP>],[OSPF=<OSPF>],[LBCL=<LBCL>], [OPT=<OPT>],[OPR=<OPR>]:<PST_PSTQ>,[<SSTQ>],[OSFBER=<OSFBER>],[OSDBER=<OSDBER>],[MACADDR=<MACADDR>],[SYNCMSG=<SYNCMSG>],[SENDDUS=<SENDDUS>], [SOAK=<SOAK>],[SOAKLEFT=<SOAKLEFT>]" ;
|
RTRV-OCHCC:[<TID>]:<AID>:<CTAG>;
Retrieves the OCH client connection provisioning information.
Output format:
SID DATE TIME M CTAG COMPLD "<AID>::[PAYLOAD=<PAYLOAD>],[CTKID=<CTKID>]:<PSTPSTQ>" ;
|
RTRV-OCHNC:[<TID>]:<AID>:<CTAG>[::::];
Retrieves the OCH wavelength connection provisioning information.
Output format:
SID DATE TIME M CTAG COMPLD "<SRC>,<DST>:<WCT>:[CKTID=<CKTID>]::<PSTPSTQ>" ;
|
RTRV-OMS:[<TID>]:<AID>:<CTAG>;
Retrieves the attributes (service parameters) and state of an OMS facility.
Output format:
SID DATE TIME M CTAG COMPLD "<AID>::RDIRN=<RDIRN>,OPTYPE=<OPTICALPORTTYPE>,[OPWR=<POWER>], EXPBAND=<EXPBAND>,[ACTBAND=<ACTBAND>],[ILOSS=<ILOSS>], [VOAMODE=<VOAMODE>],[VOAATTN=<VOAATTN>],[VOAPWR=<VOAPWR>], [VOAREFATTN=<VOAREFATTN>],[VOAREFPWR=<VOAREFPWR>], [REFOPWR=<REFOPWR>],[CALOPWR=<CALOPWR>],[CHPOWER=<CHPOWER>], [NAME=<NAME>]:<PST_PSTQ>,[<SSTQ>]" ;
|
RTRV-OPM:[<TID>]:[<AID>]:<CTAG>[::::];
Retrieves the optical power monitoring (OPM) parameters present at OCH layer in a ROADM node.
Output format:
SID DATE TIME M CTAG COMPLD "<AID>::[POWEROUT=<POWEROUT>],[POWERADD=<POWERADD>], [POWERPT=<POWERPT>]" ;
|
RTRV-OSC:[<TID>]:<AID>:<CTAG>;
Retrieves all of the OSC information of the NE.
Output format:
SID DATE TIME M CTAG COMPLD "<AID>::[RINGID=<RINGID>],[NODEID=<NODEID>],[EAST=<EAST>],[WEST=<WEST>]" ;
|
RTRV-OTS:[<TID>]:<AID>:<CTAG>;
Retrieves the attributes (service parameters) and state of an OTS facility.
Output format:
SID DATE TIME M CTAG COMPLD "<AID>:RDIRN=<RDIRN>,OPTYPE=<OPTICALPORTTYPE>,[OPWR=<POWER>], [ILOSS=<ILOSS>],[VOAMODE=<VOAMODE>],[VOAATTN=<VOAATTN>], [VOAPWR=<VOAPWR>],[VOAREFATTN=<VOAREFATTN>], [VOAREFPWR=<VOAREFPWR>],[OSRI=<OSRI>],[AMPLMODE=<AMPLMODE>], [CHPOWER=<CHPOWER>],[GAIN=<GAIN>],[EXPGAIN=<EXPGAIN>], [REFOPWR=<REFOPWR>],[OFFSET=<OFFSET>],[REFTILT=<REFTILT>], [CALTILT=<CALTILT>],[ASEOPWR=<ASEOPWR>],[DCULOSS=<DCULOSS>], [AWGST=<AWGST>],[HEATST=<HEATST>],[NAME=<NAME>]:<PST_PSTQ>,[<SSTQ>]" ;
|
RTRV-PATH-OCH:[<TID>]:<AID>:<CTAG>;
Retrieves the OCH path inside a node.
Output format:
SID DATE TIME M CTAG COMPLD "<AID>:[WLEN],[PATH]:" ;
|
RTRV-PROTNSW-OCH:[<TID>]:<AID>:<CTAG>;
Retrieves the protection switch status of a TXPP_MR_2.5G card.
Output format:
SID DATE TIME M CTAG COMPLD "<AID>:<SW>,<SWTYPE>" ;
|
RTRV-SLV-WDMANS:[<TID>]:<AID>:<CTAG>;
Retrieves the options provisionable by the ED-SLV-WDMANS command.
Output format:
SID DATE TIME M CTAG COMPLD "<AID>::[HIGHSLVEXP=<HIGHSLVEXP>],[LOWSLVEXP=<LOWSLVEXP>], [SLVACT=<SLVACT>],[RESOLUTION=<RESOLUTION>]" ;
|
RTRV-TRC-OCH:[<TID>]:<SRC>:<CTAG>::[<MSGTYPE>],[<TRCLEVEL>][::];
Retrieves the sent trace string, expected trace string, received trace string, trace mode, and the trace level for the SONET J0 Section, the TTI PATH and SECTION monitoring levels of the DWDM facility.
Output format:
SID DATE TIME M CTAG COMPLD "<CHANNEL>,<MOD>::[TRCLEVEL=<TRCLEVEL>],[EXPTRC=<EXPTRC>],[TRC=<TRC>], [INCTRC=<INCTRC>],[TRCMODE=<TRCMODE>],[TRCFORMAT=<TRCFORMAT>]" ;
|
RTRV-WDMANS:[<TID>]:<AID>:<CTAG>;
Retrieves the automatic optical node setup (AONS) application attributes.
Output format:
SID DATE TIME "<AID>::[POWERIN=<POWERIN>],[POWEROUT=<POWEROUT>], [POWEREXP=<POWEREXP>],[NTWTYPE=<NTWTYPE>], [OPTICALTYPE=<OPTICALTYPE>],[LASTRUNDAT=<LASTRUNDAT>], [LASTRUNTM=<LASTRUNTM>]" ;
|
SET-ALMTH-<MOD2>:[<TID>]:<AID>:<CTAG>::<CONDTYPE>,<THLEV>[,,,];
Sets alarm thresholds on MXP_2.5G_10G, TXP_MR_10G, TXP_MR_2.5G, TXPP_MR_2.5G, OSCM, OSC-CSM, OPT-PRE, OPT-BST, MD-4, MUX-32, DMX-32, AD-1C, AD-2C, AD-4C, AD-1B, AD-4B facilities, ports and channels.
|