cc/td/doc/product/ong/15400/r70docs
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table Of Contents

SET Commands

23.1  SET-ALMTH-<MOD2>

23.2  SET-ALMTH-EQPT

23.3  SET-ATTR-CONT

23.4  SET-ATTR-ENV

23.5  SET-ATTR-SECUDFLT

23.6  SET-PMMODE-<STS_PATH>

23.7  SET-PMMODE-<VT_PATH>

23.8  SET-TH-<MOD2>

23.9  SET-TOD


SET Commands


This chapter provides set (SET) commands for the Cisco ONS 15454, ONS 15327, ONS 15310-CL, ONS 15310-MA, and ONS 15600.

23.1  SET-ALMTH-<MOD2>

(Cisco ONS 15454, ONS 15327, ONS 15310-CL, ONS 15310-MA) The Set Alarm Threshold for 10GFC, 10GIGE, 1GFC, 1GFICON, 2GFC, 2GFICON, CLNT, D1VIDEO, DS1, DV6000, E1, E3, E4, EC1, ESCON, ETRCLO, FSTE, G1000, GFPOS, GIGE, HDTV, ISC1, OC12, OC192, OC3, OC48, OCH, OMS, OTS, POS, STS1, STS12C, STS18C, STS192C, STS24C, STS36C, STS3C, STS48C, STS6C, STS9C, T1, T3, VC12, VC3, VT1, or VT2 (SET-ALMTH-<MOD2>) command sets the alarm thresholds on the following cards/ports/channels: MXP_2.5G_10G, TXP_MR_10G, optical service channel (OSC), optical amplifier, dispersion compensation unit (DCU), multiplexer, demultiplexer, and optical add/drop multiplexing (OADM).

Usage Guidelines

The only applicable MOD2 values are CLNT, OCH, OMS, and OTS.

Category

Fault

Security

Provisioning

Input Format

SET-ALMTH-<MOD2>:[<TID>]:<AID>:<CTAG>::<CONDTYPE>,<THLEV>[,,,];

Input Example

SET-ALMTH-{MOD2}::FAC-1-1:1::OPT-LOW,10;

Input Parameters

<AID>

Access identifier from the "ALL" section. Must not be null.

<CONDTYPE>

Condition type for an alarm or a reported event. The parameter type is ALM_THR, which is the alarm threshold list for MXP_2.5G_10G, TXP_MR_10G, OSCM, OSC-CSM, OPT-PRE, OPT-BST, MD-4, MUX-32, DMX-32, AD-1C, AD-2C, AD-4C, AD-1B, and AD-4B cards.

BATV-EHIGH

Battery Voltage—Extremely High

BATV-ELOW

Battery Voltage—Extremely Low

BATV-HIGH

Battery Voltage—High

BATV-LOW

Battery Voltage—Low

GAIN-HDEG

Gain not reached—High Degrade Threshold

GAIN-HFAIL

Gain not reached—High Failure Threshold

GAIN-LDEG

Gain not reached—Low Degrade Threshold

GAIN-LFAIL

Gain not reached—Low Failure Threshold

LBCL-HIGH

Laser Bias current in microA as one tenth of a percentage. High Warning Threshold, Low Warning Threshold. Measured value (0.0 percent, 100.0 percent)

OPR-HIGH

Receive power in one tenth of a microW. Measured value (-40.0 dBm, +30.0 dBm)

OPR-LOW

Receive power in one tenth of a microW. Measured value (-40.0 dBm, +30.0 dBm)

OPT-HIGH

Transmit power in one tenth of a microW. Measured value (-40.0 dBm, +30.0 dBm)

OPT-LOW

Transmit power in one tenth of a microW. Measured value (-40.0 dBm, +30.0 dBm)

OPWR-HDEG

Optical Power—High Degrade Threshold

OPWR-HFAIL

Optical Power—High Failure Threshold

OPWR-LDEG

Optical Power—Low Degrade Threshold

OPWR-LFAIL

Optical Power—Low Failure Threshold

VOA-HDEG

VOA Attenuation—High Degrade Threshold

VOA-HFAIL

VOA Attenuation—High Failure Threshold

VOA-LDEG

VOA Attenuation—Low Degrade Threshold

VOA-LFAIL

VOA Attenuation—Low Failure Threshold

<THLEVEL>

Threshold level. THLEVEL is a float.


23.2  SET-ALMTH-EQPT

(Cisco ONS 15454) The Set Alarm Threshold Equipment (SET-ALMTH-EQPT) command sets the alarm thresholds to manage the power level monitoring on an NE.

Usage Guidelines

None

Category

Equipment

Security

Provisioning

Input Format

SET-ALMTH-EQPT:[<TID>]:[<AID>]:<CTAG>::<ALMTHTYPE>,<THLEV>[,,,];

Input Example

SET-ALMTH-EQPT:::1::BATV-HIGH,-53.5;

SET-ALMTH-EQPT::SHELF-2:1::BATV-HIGH,-53.5;

Input Parameters

<AID>

The node or shelf access identifier from the "SHELF" section. If omitted it addresses the node or first shelf of the node. Must not be null

<CONDTYPE>

Alarm threshold type. The parameter type is ALM_THR, which is the alarm threshold list for MXP_2.5G_10G, TXP_MR_10G, OSCM, OSC-CSM, OPT-PRE, OPT-BST, MD-4, MUX-32, DMX-32, AD-1C, AD-2C, AD-4C, AD-1B, and AD-4B cards.

BATV-EHIGH

Battery Voltage—Extremely High

BATV-ELOW

Battery Voltage—Extremely Low

BATV-HIGH

Battery Voltage—High

BATV-LOW

Battery Voltage—Low

GAIN-HDEG

Gain not reached—High Degrade Threshold

GAIN-HFAIL

Gain not reached—High Failure Threshold

GAIN-LDEG

Gain not reached—Low Degrade Threshold

GAIN-LFAIL

Gain not reached—Low Failure Threshold

LBCL-HIGH

Laser Bias current in microA as one tenth of a percentage High Warning Threshold, Low Warning Threshold. Measured value (0.0 percent, 100.0 percent)

OPR-HIGH

Receive power in one tenth of a microW. Measured value (-40.0 dBm, +30.0 dBm)

OPR-LOW

Receive power in one tenth of a microW. Measured value (-40.0 dBm, +30.0 dBm)

OPT-HIGH

Transmit power in one tenth of a microW. Measured value (-40.0 dBm, +30.0 dBm)

OPT-LOW

Transmit power in one tenth of a microW. Measured value (-40.0 dBm, +30.0 dBm)

OPWR-HDEG

Optical Power—High Degrade Threshold

OPWR-HFAIL

Optical Power—High Failure Threshold

OPWR-LDEG

Optical Power—Low Degrade Threshold

OPWR-LFAIL

Optical Power—Low Failure Threshold

VOA-HDEG

VOA Attenuation—High Degrade Threshold

VOA-HFAIL

VOA Attenuation—High Failure Threshold

VOA-LDEG

VOA Attenuation—Low Degrade Threshold

VOA-LFAIL

VOA Attenuation—Low Failure Threshold

<THLEVEL>

Threshold level. THLEV is a float.


23.3  SET-ATTR-CONT

(Cisco ONS 15454, ONS 15327, ONS 15310-CL, ONS 15310-MA, ONS 15600) The Set Attribute Control (SET-ATTR-CONT) command sets the attributes associated with an external control. The attributes are used when an external control is operated or released. To send the attributes, use the RTRV-ATTR-CONT command.

Usage Guidelines

If the CONTTYPE parameter is not specified, the control specified by AID is unprovisioned.

A control should be unprovisioned before it is reprovisioned to another type of control.

Category

Environment

Security

Provisioning

Input Format

SET-ATTR-CONT:[<TID>]:<AID>:<CTAG>[::<CONTTYPE>];

Input Example

SET-ATTR-CONT:CISCO:ENV-OUT-1:123::AIRCOND;

Input Parameters

<AID>

Access identifier from the "ENV" section. Identifies the external control for which attributes are being retrieved.

<CONTTYPE>

Environmental control type. A null value is equivalent to ALL. The parameter type is CONTTYPE, which is the environmental control type.

AIRCOND

Air conditioning

AUDIBLE

Audible (ONS 15310-MA only)

ENGINE

Engine

FAN

Fan

GEN

Generator

HEAT

Heat

LIGHT

Light

MISC

Miscellaneous

SPKLR

Sprinkler


23.4  SET-ATTR-ENV

(Cisco ONS 15454, ONS 15327, ONS 15310-CL, ONS 15310-MA, ONS 15600) The Set Attribute Environment (SET-ATTR-ENV) command sets the attributes associated with an external control.

Usage Guidelines

If the NTFCNCDE, ALMTYPE, and ALMMSG parameters are omitted, the environmental alarm specified by AID is unprovisioned.

An alarm should be unprovisioned and you should wait for any raised alarm to clear before reprovisioning the alarm to another alarm type.

CL in NOTIF_CODE is not valid for provisioning commands. It is only valid for autonomous messages.

Category

Environment

Security

Provisioning

Input Format

SET-ATTR-ENV:[<TID>]:<AID>:<CTAG>::[<NTFCNCDE>],[<ALMTYPE>],[<ALMMSG>];

Input Example

SET-ATTR-ENV:CISCO:ENV-IN-1:123::MJ,OPENDR,\"OPEN DOOR\";

Input Parameters

<AID>

Access identifier from the "ENV" section. Must not be null.

<NTFCNCDE>

Two-letter notification code. Must not be null. The parameter type is NOTIF_CODE, which is the two-character notification code associated with an autonomous message.

CL

The condition causing the alarm has cleared.

CR

A critical alarm.

MJ

A major alarm.

MN

A minor alarm.

NA

The condition is not alarmed.

NR

The alarm is not reported.

<ALMTYPE>

The alarm type for the environmental alarm. Must not be null. The parameter type is ENV_ALM, which is the environmental alarm type.

AIRCOMPR

Air compressor failure

AIRCOND

Air conditioning failure

AIRDRYR

Air dryer failure

BATDSCHRG

Battery discharging

BATTERY

Battery failure

CLFAN

Cooling fan failure

CPMAJOR

Centralized power major failure

CPMINOR

Centralized power minor failure

ENGINE

Engine failure

ENGOPRG

Engine operating

ENGTRANS

Standby engine transfer

EXPLGS

Explosive gas

FIRDETR

Fire detector failure

FIRE

Fire

FLOOD

Flood

FUELLEAK

Fuel leak

FUSE

Fuse failure

GASALARM

Explosive gas, toxic gas, ventilation fail, or gas monitor fail

HATCH

CEV hatch fail

GEN

Generator failure

HIAIR

High airflow

HIHUM

High humidity

HITEMP

High temperature

HIWTR

High water

INTRUDER

Intrusion

LEVELCON

Level converter

LVDADSL

Secondary ADSL low voltage disconnect

LVDBYPAS

Low voltage disconnected bypass

LWBATVG

Low battery voltage

LWFUEL

Low fuel

LWHUM

Low humidity

LWPRES

Low cable pressure

LWTEMP

Low temperature

LWWTR

Low water

MISC

Miscellaneous

OPENDR

Open door

POWER

Commercial power failure

PUMP

Pump failure

PWR-48

48 V power supply failure

PWR-139

-139 V power converter

PWR-190

-190 V power converter

PWRMJ

Power supply major

PWRMN

Power supply minor

RECT

Rectifier failure

RECTHI

Rectifier high voltage

RECTLO

Rectifier low voltage

RINGGENMJ

Ringing generator major

RINGGENMN

Ringing generator minor

RTACADSL

AC or AC/rectifier power fail ADSL equipment

RTACCRIT

AC or AC/rectifier power fail DCL equipment critical site

RTACPWR

AC or AC/rectifier power fail DCL equipment

RTACPWRENG

Commercial AC fail, site equipped with standby engine

RTBAYPWR

AC power loss distributed power RT bay

RTRVENG

Retrieve standby engine, commercial AC restored

SMOKE

Smoke

TEMP

High-low temperature

TOXICGAS

Toxic gas

TREPEATER

T-repeater shelf

VENTN

Ventilation system failure

>ALMMSG>

Alarm message. ALMMSG is a string. Must not be null.


23.5  SET-ATTR-SECUDFLT

(Cisco ONS 15454, ONS 15327, ONS 15310-CL, ONS 15310-MA, ONS 15600) The Set Attribute Security Default (SET-ATTR-SECUDFLT) command sets the system-wide default values associated with several security parameters.

Usage Guidelines

The following parameters are set on a system-wide basis for all users and all privilege levels: MXINV, DURAL, UOUT, PFRCD, POLD, PINT, and LOGIN. The PRIVLVL keyword cannot be used to set these parameters for a specific privilege level.

The following parameters are set on a privilege-level basis: PAGE, PCND, and TMOUT. If any of these values are specified, the PRIVLVL keyword must also be present. If none of these parameters are specified, the PRIVLVL keyword cannot be used.


Note Password aging can only be enabled/disabled for all privilege levels. The PRIVLVL keyword cannot be used with PAGE=0 to disable a specific user privilege level.


When system-level and privilege-level keywords are combined in the same command, system-level parameters are still set for all privilege levels, regardless of the value specified by PRIVLVL. Privilege-level parameters are only set for the privilege level specified by PRIVLVL.


Note If PAGE and PINT both have values greater than 0, PINT must be less than PAGE.


The order of keywords is not restricted. Commas are only needed to separate keywords. If no keywords are specified, all parameters are left as-is.

Category

Security

Security

Superuser

Input Format

SET-ATTR-SECUDFLT:[<TID>]::<CTAG>::[PAGE=<PAGE>],[PCND=<PCND>],
[MXINV=<MXINV>],[DURAL=<DURAL>],[TMOUT=<TMOUT>],[UOUT=<UOUT>],
[PFRCD=<PFRCD>],[POLD=<POLD>],[PINT=<PINT>],[LOGIN=<LOGIN>],
[PRIVLVL=<PRIVLVL>],[PDIF=<PDIF>];

Input Example

SET-ATTR-SECUDFLT:CISCO::123::PAGE=45,PCND=5,MXINV=5,DURAL=30,
TMOUT=0,UOUT=20,PFRCD=NO,POLD=5,PINT=20,LOGIN=MULTIPLE,
PRIVLVL=RTRV,PDIF=1;

Input Parameters

<PAGE>

Password aging interval. It is the number of days before a user is prompted to change his/her password. 0 indicates that the policy is turned off and is the default. If PAGE is turned on for all privilege levels and is not specified for each privilege level, it defaults to 45 days. PAGE ranges from 20 to 90 days. PAGE is an integer.

<PCND>

Number of days a password can be used before a new one is mandatory (for example, the warning period). Default is 5 days. PCND ranges from 2 to 20 days. PCND is an integer.

<MXINV>

Maximum number of consecutive and invalid session setup attempts allowed to occur before an intrusion attempt is suspected (for example, "Failed Logins Before Lockout" from Cisco Transport Controller [CTC]). 0 indicates the policy is turned off. Default is 5. MXINV ranges from 0 to 10. MXINV is an integer.

<DURAL>

Time interval (in seconds) during which a user ID is locked out when an intrusion attempt is suspected (for example, "Lockout Duration"). If the user is locked out until unlocked by a Superuser, DURAL=INFINITE. Default is 30 seconds. DURAL ranges from 0 to 600 seconds. DURAL is a string.

<TMOUT>

Interval (in minutes) after which a session is terminated if no messages are exchanged between the user and the NE. 0 indicates that the session will not timeout. TMOUT ranges from 0 minutes to 999 minutes. Defaults are 0 (no timeout) for RTRV users, 60 minutes for MAINT users, 30 minutes for PROV users, and 15 minutes for SUPER users. TMOUT is an integer.

<UOUT>

UID aging interval, expressed in days. If a user ID has not been used in UOUT days, the user will be forced to change his/her password (or logout) at the next login. No other command is allowed until the password has been changed. 0 indicates the policy is turned off and is the default. UOUT ranges from 0 to 99 days. UOUT is an integer.

<PFRCD>

Indicates that a password change is required when a new user establishes a session to the NE for the first time (for example, "Require password change on 1st login"). Default is NO. The parameter type is YES_NO, which indicates whether the user's password is about to expire, the user is logged into the NE, or the user is locked out of the NE.

NO

No

YES

Yes

<POLD>

Number of prior passwords that cannot be reused (for example, "Prevent reusing last X passwords"). Default is 1. POLD ranges from 1 to 10. POLD is an integer.

<PINT>

Number of days that must pass before a password can be changed. If PINT is 0, the policy is turned off. Default is off. PINT ranges from 20 to 95 days. PINT is an integer.

<LOGIN>

Number of times a user can log into an NE. LOGIN is either SINGLE or MULTIPLE. If LOGIN is SINGLE, a user can only log into an NE one time with any given user ID, regardless of the method of login (for example, CTC, TL1, etc.). Default is MULTIPLE. The parameter type is USER_LOGINS, which is the number of times a user can log into the same NE with the same user ID.

MULTIPLE

A user can log into the same NE many times.

SINGLE

A user can log into the NE only once (includes both CTC and TL1 sessions).

<PRIVLVL>

User's access privilege. The parameter type is PRIVILEGE, which is the security level.

MAINT

Maintenance security level. 60 minutes of idle time.

PROV

Provision security level. 30 minutes of idle time.

RTRV

Retrieve security level. Unlimited idle time.

SUPER

Superuser security level. 15 minutes of idle time.

<PDIF>

Indicates how many characters must differ between the old and new password. Default minimum character difference is 1. PDIF ranges from 1 to 5 characters. PDIF is a rangeable integer.


23.6  SET-PMMODE-<STS_PATH>

(Cisco ONS 15454) The Set Performance Mode of PM Data Collection for STS1, STS12C, STS18C, STS192C, STS24C, STS36C, STS3C, STS48C, STS6C, or STS9C (SET-PMMODE-<STS_PATH>) command sets the mode and turns the performance monitoring (PM) data collection mode on or off.

Usage Guidelines

See Table 27-1 for supported modifiers by platform.


NoteThe PM mode and state of an entity are retrieved by using the RTRV-PMMODE command.

The near-end monitoring of the intermediate-path performance monitoring (IPPM) only supports OC3, OC12, OC48, OC192, and EC-1 on STS Path.

The far-end IPPM data collection is supported by the MRC-12 card only.

This release of software will support only the Path (P) mode type PM parameters with this command, that is, this command is not applicable for Line (L) and Section (S) mode types. PM monitoring for Line (L) and Section (S) are supported by the ONS 15454, and the storing PM data is always performed.


Category

Performance

Security

Provisioning

Input Format

SET-PMMODE-<STS_PATH>:[<TID>]:<SRC>:<CTAG>::<LOCN>,<MODETYPE>,
[<PMSTATE>];

Input Example

SET-PMMODE-STS1:CISCO:STS-4-1-2:123::NEND,P,ON;

Input Parameters

<SRC>

Source access identifier from the "CrossConnectId" section.

<LOCN>

Location associated with a particular command. Identifies the location from which the PM mode is to be retrieved. Only near-end PM data collection is supported. The parameter type is LOCATION, which is the location where the action is to take place.

NEND

Action occurs on the near end of the facility.

<MODETYPE>

The type of PM parameters that the entity or the sub entity is to store as a result of an attribute change. Only the path (P) PM parameter is supported. The parameter type is PM_MODE, which is the type of PM parameter.

P

Transport Path PM parameters

<PMSTATE>

Directs the named PM mode type to turn on or off. A null value defaults to on. The parameter type is PM_STATE, which directs the named PM mode type (P) state.

OFF

Disable the mode

ON

Enable the mode


23.7  SET-PMMODE-<VT_PATH>

(Cisco ONS 15310-MA) The Set Performance Mode of PM Data Collection for VT1 and VT2 (SET-PMMODE-<VT_PATH>) command sets the mode and turns the performance monitoring (PM) data collection mode on or off.

Usage Guidelines


NoteThe PM mode and state of an entity is retrieved by using the RTRV-PMMODE command.

This release of software will support only the Path (P) mode type PM parameters with this command, that is, this command will not be applicable for Line (L) and Section (S) mode types.


Category

Performance

Security

Provisioning

Input Format

SET-PMMODE-<VT_PATH>:[<TID>]:<SRC>:<CTAG>::<LOCN>,<MODETYPE>,[<PMSTATE>];

Input Example

SET-PMMODE-VT1:CISCO:VT1-1-1-2-2:123::NEND,P,ON;

Input Parameters

<SRC>

Source access identifier from the "CrossConnectId1" section. Must not be null.

<LOCN>

Location associated with a particular command. Identifies the location from which the PM mode is to be set. Only near end (NEND)PM data collection is supported. The parameter type is LOCATION, which is the location where the action is to take place. Must not be null.

NEND

Action occurs on the near end of the facility.

<MODETYPE>

The type of PM parameters that the entity or the subentity is to store as a result of an attribute change. Only the path (P) type is supported. The parameter type is PM_MODE, which is the type of PM parameters.

P

Transport Path PM parameters.

<PMSTATE>

Directs the named PM mode type to turn on or off. A null value defaults to on. The parameter type is PM_STATE, which directs the named PM mode type (P) state.

OFF

Disable the mode

ON

Enable the mode


23.8  SET-TH-<MOD2>

(Cisco ONS 15454, ONS 15327, ONS 15310-CL, ONS 15310-MA, ONS 15600) The Set Threshold for 10GFC, 10GIGE, 1GFC, 1GFICON, 2GFC, 2GFICON, CLNT, D1VIDEO, DS1, DS3I, DV6000, E1, E3, E4, EC1, ESCON, ETRCLO, FSTE, G1000, GFPOS, GIGE, HDTV, ISC1, OC12, OC192, OC3, OC48, OCH, OMS, OTS, POS, STM1E, STS1, STS12C, STS18C, STS192C, STS24C, STS36C, STS3C, STS48C, STS6C, STS9C, T1, T3, VC11, VC12, VC3, VT1, or VT2 (SET-TH-<MOD2>) command sets the threshold for PMs and sets the alarm thresholds for the MXP_2.5G_10G and TXP_MR_10G cards. If this command is used to set the alarm thresholds, the time period is not applicable.

Usage Guidelines

See Table 27-1 for supported modifiers by platform.

The rules are as follows:

The PM Thresholds have a default of NEND for the location. The Alarm Thresholds do not require or interpret the location.

The TMPER is not applicable to alarm thresholds. The TMPER default is 15-MIN.

The client ports only accept SONET, Laser, and alarm MONTYPEs. The trunk ports accept SONET, Laser, alarm, FEC, OTN, and 8B10B MONTYPEs.

Refer to the Cisco ONS SONET TL1 Reference Guide for specific card provisioning rules.

Category

Performance

Security

Provisioning

Input Format

SET-TH-<MOD2>:[<TID>]:<AID>:<CTAG>::<MONTYPE>,<THLEV>,[<LOCN>],,[<TMPER>];

Input Example

SET-TH-T3:CISCO:FAC-1-1:123::CVL,12,NEND,,15-MIN;

Input Parameters

<AID>

Access identifier from the "ALL" section. All of the STS, VT1, Facility, and DS1 AIDs are supported.

<MONTYPE>

Monitored type. The parameter type is ALL_MONTYPE, which is the monitoring type list.

AISSP

Alarm Indication Signal SecondsPath

ALL

All possible values

BBE-PM

OTN—Background Block Errors—Path Monitor Point

BBE-SM

OTN—Background Block Errors—Section Monitor Point

BBER-PM

OTN—Background Block Error Ratio—Path monitor point expressed as one tenth of a percentage

BBER-SM

OTN—Background Block Error Ratio—Section monitor point expressed as one tenth of a percentage

BIEC

FEC—Bit Errors Corrected

CGV

8B10B—Code Group Violations

CSSP

Controlled Slip Seconds—Path (DSXM-12 FDL/T1.403 PM count)

CVCPP

Coding Violations—CP-Bit Path

CVL

Coding Violations—Line

CVP

Coding Violations—Path

CVS

Coding Violations—Section

CVV

Coding Violations—Section

DCG

8B10B—Data Code Groups

ESAP

Errored Second Type A-Path (DS3XM-12 DS1 PM count)

ESBP

Errored Second Type B-Path (DS3XM-12 DS1 PM count)

ESCPP

Errored Seconds—CPBit Path

ESL

Errored Seconds—Line

ESNPFE

Errored SecondNetwork Path (DS3XM-12 DS1 PM count)

ESP

Errored Seconds—Path

ES-PM

OTN—Errored Seconds—Path Monitor Point

ES-SM

OTN—Errored Seconds—Section Monitor Point

ESR

Errored Second—Ratio

ESR-PM

Errored Seconds Ratio—Path monitor point expressed as one tenth of a percentage

ESR-SM

Errored Seconds Ratio—Section monitor point expressed as one tenth of a percentage

ESS

Errored Seconds—Section

ESV

Errored Seconds—VT Path

etherStatsBroadcastPkts

The total number of good packets received that were directed to a multicast address

etherStatsCollisions

Number of transmit packets that are collisions

etherStatsCRCAlignErrors

The total number of packets received that have a length (excluding framing bits, but including FCS octets) of between 64 and 1518 octets

etherStatsDropEvents

Number of received frames dropped at the port level

etherStatsFragments

The total number of packets received that were less than 64 octets

etherStatsJabbers

The total number of packets received that are longer than 1518 octets

etherStatsOctets

The total number of octets of data

etherStatsOversizePkts

The total number of packets received that are longer than 1518 octets

etherStatsPkts

The total number of packets (including bad packets, broadcast packets, and multicast packets) received

etherStatsUndersizePkts

The total number of packets received that are less than 64 octets

FC-L

Failure Count—Line

FC-P

Failure Count—Path

FC-PM

OTN—Failure Count—Path Monitor Point

FC-SM

OTN—Failure Count—Section Monitor Point

HP-AR

Availability Ratio

HP-BBE

High-Order Path Background Block Error

HP-BBER

High-Order Path Background Block Error Ratio

HP-EB

High-Order Path Errored Block

HP-ES

High-Order Path Errored Second

HP-ESA

High-Order Path Errored Seconds—A

HP-ESB

High-Order Path Errored Seconds—B

HP-ESR

High-Order Path Errored Second Ratio

HP-FC

High-Order Path Failure Count

HP-NPJC-PDET

High-Order Path Negative Pointer Justification Count

HP-NPJC-PGEN

High-Order Path, Negative Pointer Justification Count

HP-OI

Outage Intensity

HP-PJCDIFF

High-Order Path Pointer Justification Count Difference

HP-PJCS-PDET

High-Order Path Pointer Justification Count

HP-PJCS-PGEN

High-Order Path Pointer Justification Count Seconds

HP-PPJC-PDET

High-Order Path Positive Pointer Justification Count

HP-PPJC-PGEN

High-Order Path, Positive Pointer Justification Count

HP-SEPI

The number of SEP events in available time

HP-SES

High-Order Path Severely Errored Seconds

HP-SESR

High-Order Path Severely Errored Second Ratio

HP-UAS

High-Order Path Unavailable Seconds

ifInBroadcastPkts

Number of broadcast packets received since the last counter reset

ifInDiscards

The number of inbound packets

ifInErrorBytePktss

Receive Error Byte

ifInErrors

The number of inbound packets (or transmission units) that contained errors

ifInFramingErrorPkts

Receive Framing Error

ifInJunkInterPkts

Receive Interpacket Junk

ifInMulticastPkts

Number of multicast packets received since the last counter reset

ifInOctets

Number of bytes transmitted since the last counter reset

ifInUcastPkts

Number of unicast packets received since the last counter reset

ifOutBroadcastPkts

Number of broadcast packets transmitted

ifOutDiscards

The number of outbound packets

ifOutErrors

The number of outbound packets (or transmission units) that could not be transmitted because of errors

ifOutMulticastPkts

Number of multicast packets transmitted

ifOutPayloadCrcErrors

Received payload cyclic redundancy check (CRC) errors

ifOutUcastPkts

Number of unicast packets transmitted

IOS

8B10B—Idle Ordered Sets

IPC

Invalid Packet Count

LBCL-AVG

Average Laser Bias current in microA

LBCL-MAX

Maximum Laser Bias current in microA

LBCL-MIN

Minimum Laser Bias current in microA

LBCN

Normalized Laser Bias Current for OC3-8

LBCN-HWT

Laser Bias Current

LBCN-LWT

Laser Bias Current

LOSSL

Loss of Signal Seconds—Line

LP-BBE

Low-Order Path Background Block Error

LP-BBER

Low-Order Path Background Block Error Ratio

LP-EB

Low-Order Path Errored Block

LP-ES

Low-Order Path Errored Second

LP-ESA

Low-Order Path Errored Seconds-A

LP-ESB

Low-Order Path Errored Seconds-B

LP-ESR

Low-Order Path Errored Second Ratio

LP-FC

Low-Order Path Failure Count

LP-NPJC-DET

Low-Order Negative Pointer Justification Count, Detected

LP-NPJC-GEN

Low Order Negative Pointer Justification Count, Generated

LP-PPJC-DET

Low-Order Positive Pointer Justification Count, Detected

LP-PPJC-GEN

Low-Order positive Pointer Justification Count, Generated

LP-SEP

Low-Order Path Severely Errored Period

LP-SEPI

Low-Order Path Severely Errored Period Intensity

LP-SES

Low-Order Path Severely Errored

LP-UAS

Low-Order Path Unavailable Seconds

MS-PSC

Protection switch count

MS-PSD

Protection switch duration

NIOS

8B10B—Non Idle Ordered Sets

NPJC-PDET

PPJC-PDET:Negative Pointer Justification

NPJC-PGEN

PPJC-PGEN:Negative Pointer Justification

OPR-AVG

Average Receive Power in one tenth of a microW

OPR-MAX

Maximum Receive Power in one tenth of a microW

OPR-MIN

Minimum Receive Power in one tenth of a microW

OPRN

Normalized Optical Receive Power for OC3-8

OPRN-MAX

Maximum value for OPRN

OPRN-MIN

Minimum value for OPRN

OPT-AVG

Average Transmit Power in one tenth of a microW

OPT-MAX

Maximum Transmit Power in one tenth of a microW

OPT-MIN

Minimum Transmit Power in one tenth of a microW

OPTN

Normalized value for Optical Power Transmitted for the OC3-8 card

OPTN-MAX

Maximum value for OPTN

OPTN-MIN

Minimum value for OPTN

OPWR-AVG

Optical Power—Average Interval Value in one tenth of a dBm

OPWR-MAX

Optical Power—Maximum Interval Value in one tenth of a dBm

OPWR-MIN

Optical Power—Minimum Interval Value in one tenth of a dBm

PPJC-PDET

PPJC-PDET:Positive Pointer Justification

PPJC-PGEN

PPJC-PGEN:Positive Pointer Justification

PSC

Protection Switching Count

PSC-R

Protection Switching Count—Ring

PSC-S

Protection Switching Count—Span

PSC-W

Protection Switching Count—Working

PSD

Protection Switching Duration

PSD-R

Protection Switching Duration—Ring

PSD-S

Protection Switching Duration—Span

PSD-W

Protection Switching Duration—Working

SASCPP

Severely Errored Framing/AIS Second—CP-Bit Path

SASP

Severely Errored Framing/AIS Seconds Path

SEFS

Severely Errored Framing Seconds

SEFSP

Severely Errored Framing Seconds—Path (DS3XM-12 DS1 PM count)

SESCPP

Severely Errored Second—CP-Bit Path

SESL

Severely Errored Second—Line

SESNPFE

Severely Errored SecondNetwork Path (DS3XM-12 DS1 PM count)

SESP

Severely Errored Second—Path

SES-PM

OTN—Severely Errored Second—Path

SESR-PM

OTN—Severely Errored Second Ratio—Path Monitor Point expressed as one tenth of a percentage

SESR-SM

OTN—Severely Errored Second Ratio—Section Monitor Point expressed as one tenth of a percentage

SESS

Severely Errored Second—Section

SES-SM

OTN—Severely Errored Second—Section Monitor Point

SESV

Severely Errored Second—VT Path

UASCPP

Unavailable Second—CP-Bit Path

UASL

Unavailable Second—Line

UASNPFE

Unavailable SecondNetwork Path (DS3XM-12 DS1 PM count)

UASP

Unavailable Second—Path

UAS-PM

OTN—Unavailable Second—Path Monitor Point

UAS-SM

OTN—Unavailable Second—Section Monitor Point

UASV

Unavailable Second—VT Path

UNC-WORDS

FEC—Uncorrectable Words

VPC

Valid Packet Count

<THELV>

Threshold level. THLEV is a float.

<LOCN>

Location associated with a particular command. The parameter type is LOCATION, which is the location where the action is to take place.

FEND

Action occurs on the far end of the facility

NEND

Action occurs on the near end of the facility

<TMPER>

(Optional) Accumulation time period for performance counters. The parameter type is TMPER, which is the accumulation time period for the performance management center.

1-DAY

Performance parameter accumulation interval length; every 24-hours. For SONET PM data, only one day of history data is available. For RMON managed PM data, seven days of history data are available.

1-HR

Performance parameter accumulation interval length; every 1 hour. This is only applicable to RMON managed PM data. There are 24 hours of history data available.

1-MIN

Performance parameter accumulation interval length; every 1 minute. This is only applicable to RMON managed PM data. There are 60 minutes of history available.

15-MIN

Performance parameter accumulation interval length; every 15 minutes. There are 32 15-MIN buckets of history data available for this accumulation interval length.

RAW-DATA

Performance parameter accumulation interval length; starting from the last time the counters were cleared. This is only applicable to RMON managed PMs.


23.9  SET-TOD

(Cisco ONS 15454, ONS 15327, ONS 15310-CL, ONS 15310-MA, ONS 15600) The Set Time of Day (SET-TOD) command sets the system date and time for the NE. The year should be entered using four digits while the hour should be entered using a 24-hour time period (for example, military time).

Usage Guidelines

None

Category

System

Security

Provisioning

Input Format

SET-TOD:[<TID>]::<CTAG>::<YEAR>,<MONTH>,<DAY>,<HOUR>,<MINUTE>,<SECOND>,
[<DIFFERENCE>][:DST=<DST>];

Input Example

SET-TOD:CAZADERO::240::1998,05,08,13,18,55,480:DST=Y;

Input Parameters

<YEAR>

The current calendar year. YEAR is an integer.

<MONTH>

The month of the year. Ranges from 01 to 12. MONTH is an integer.

<DAY>

The day of the month. Ranges from 01 to 31. DAY is an integer.

<HOUR>

The hour of the day. Ranges from 00 to 23. HOUR is an integer.

<MINUTE>

The minute of the hour. Ranges from 00 to 59. MINUTE is an integer.

<SECOND>

The second of the minute. Ranges from 00 to 59. SECOND is an integer.

<DIFFERENCE>

The number of minutes off UTC. DIFFERENCE is an integer.

<DST>

Daylight savings time. The parameter type is ON_OFF (disable or enable an attribute).

N

Disable an attribute.

Y

Enable an attribute.



hometocprevnextglossaryfeedbacksearchhelp

Posted: Thu Sep 13 02:41:21 PDT 2007
All contents are Copyright © 1992--2007 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.