Table Of Contents
11.19 ED-FFP-<MOD2DWDMPAYLOAD>
ED Commands
Note The terms "Unidirectional Path Switched Ring" and "UPSR" may appear in Cisco literature. These terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring configuration. Rather, these terms, as well as "Path Protected Mesh Network" and "PPMN," refer generally to Cisco's path protection feature, which may be used in any topological network configuration. Cisco does not recommend using its path protection feature in any particular topological network configuration.
This chapter provides edit (ED) commands for the Cisco ONS 15454, ONS 15327, ONS 15310-CL, ONS 15310-MA, and ONS 15600.
11.1 ED-<GIGE_TYPE>
(Cisco ONS 15454, ONS 15600) The Edit 10GIGE or GIGE (ED-<GIGE_TYPE>) command edits Ethernet facility attributes.
Usage Guidelines
•See Table 27-1 for supported modifiers by platform.
•The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. In order to obtain the current value, issue the RTRV-XX command.
•The following parameters apply only to ED-GIGE; ADMINSTATE, LINKSTATE, MTU, FLOWCTRL, AUTONEG, HIWMRK, LOWMRK, DUPLEX, SPEED, SOAK.
•The MACADDR parameter is applicable for ED-10GIGE only.
CategoryPorts
SecurityProvisioning
Input FormatED-<GIGE_TYPE>:[<TID>]:<AID>:<CTAG>:::[ADMINSTATE=<ADMINSTATE>],
[LINKSTATE=<LINKSTATE>],[MTU=<MTU>],[FLOWCTRL=<FLOWCTRL>],
[AUTONEG=<AUTONEG>],[HIWMRK=<HIWMRK>],[LOWMRK=<LOWMRK>],
[OPTICS=<OPTICS>],[DUPLEX=<DUPLEX>],[SPEED=<SPEED>],[NAME=<NAME>],
[CMDMDE=<CMDMDE>],[MACADDR=<MACADDR>],[FREQ=<FREQ>],[LOSSB=<LOSSB>],
[SOAK=<SOAK>]:[<PST>[,<SST>]];Input ExampleED-GIGE:CISCO:FAC-1-1:123:::ADMINSTATE=DOWN,LINKSTATE=DOWN,MTU=1548,
FLOWCTRL=NONE,AUTONEG=Y,HIWMRK=485,LOWMRK=25,OPTICS=1000_BASE_LX,
DUPLEX=AUTO,SPEED=AUTO,NAME="GIGE PORT",CMDMDE=FRCD,
MACADDR=00-0E-AA-BB-CC-FF,FREQ=1550,LOSSB=SX,SOAK=32:IS,AINS;Input Parameters
<AID>
Access identifier from the "FACILITY" section.
<ADMINSTATE>
The parameter type is UP_DOWN which indicates an up or down value
•DOWN
Down
•UP
Up
<LINKSTATE>
The parameter type is UP_DOWN which indicates an up or down value
•DOWN
Down
•UP
Up
<MTU>
Maximum transport unit. The parameter type is MTU_TYPE which indicates the maximum transport unit used by an Ethernet card. Defaults to 9600.
•10004
10004. Indicates jumbo size.
•1500
1500
•1548
1548
•9600
9600. Indicates the jumbo size.
<FLOWCTRL>
Flow control. The parameter is FLOW which indicates the type of flow control that has been negotiated for an Ethernet port. Defaults to NONE.
•ASYMMETRIC
Asymmetric flow control
•ASYMMETRIC_LOCAL
Asymmetric local flow control
•NONE
No flow control
•PASSTHRU
Passthrough flow control
•SYMMETRIC
Symmetric flow control
<AUTONEG>
Autonegotiation. The parameter is ON_OFF which disables or enables an attribute. Defaults to Y.
•N
Disable an attribute
•Y
Enable an attribute
<HIWMRK>
High water mark. Integer. Defaults to 485.
<LOWMRK>
Low water mark. Integer. Defaults to 25.
<OPTICS>
The parameter is OPTICS which indicates the type of Gigabyte Ethernet optics being used.
•1000_BASE_CX
1000 Base CX
•1000_BASE_LX
1000 Base LX
•1000_BASE_SX
1000 Base SX
•1000_BASE_ZX
1000 Base ZX
•100_BASE_FX
100 Base FX
•100_BASE_LX
100 Base LX
•CWDM_1470
Coarse wavelength division multiplexing (CWDM) 1470
•CWDM_1490
CWDM 1490
•CWDM_1510
CWDM 1510
•CWDM_1530
CWDM 1530
•CWDM_1550
CWDM 1550
•CWDM_1570
CWDM 1570
•CWDM_1590
CWDM 1590
•CWDM_1610
CWDM 1610
•ITU_100G_1530_33
ITU-100G 1530.33
•ITU_100G_1531_12
ITU-100G 1531.12
•ITU_100G_1531_90
ITU-100G 1531.90
•ITU_100G_1532_68
ITU-100G 1532.68
•ITU_100G_1534_25
ITU-100G 1534.25
•ITU_100G_1535_04
ITU-100G 1535.04
•ITU_100G_1535_82
ITU-100G 1535.82
•ITU_100G_1536_61
ITU-100G 1536.61
•ITU_100G_1538_19
ITU-100G 1538.19
•ITU_100G_1538_98
ITU-100G 1538.98
•ITU_100G_1539_77
ITU-100G 1539.77
•ITU_100G_1540_56
ITU-100G 1540.56
•ITU_100G_1542_14
ITU-100G 1542.14
•ITU_100G_1542_94
ITU-100G 1542.94
•ITU_100G_1543_73
ITU-100G 1543.73
•ITU_100G_1544_53
ITU-100G 1544.53
•ITU_100G_1546_12
ITU-100G 1546.12
•ITU_100G_1546_92
ITU-100G 1546.92
•ITU_100G_1547_72
ITU-100G 1547.72
•ITU_100G_1548_51
ITU-100G 1548.51
•ITU_100G_1550_12
ITU-100G 1550.12
•ITU_100G_1550_92
ITU-100G 1550.92
•ITU_100G_1551_72
ITU-100G 1551.72
•ITU_100G_1552_52
ITU-100G 1552.52
•ITU_100G_1554_13
ITU-100G 1554.13
•ITU_100G_1554_94
ITU-100G 1554.94
•ITU_100G_1555_75
ITU-100G 1555.75
•ITU_100G_1556_55
ITU-100G 156.55
•ITU_100G_1558_17
ITU-100G 1558.17
•ITU_100G_1558_98
ITU-100G 1558.98
•ITU_100G_1559_79
ITU-100G 1559.79
•ITU_100G_1560_61
ITU-100G 1560.61
•UNKNOWN
Unknown
•UNPLUGGED
Unplugged
<DUPLEX>
The parameter is ETHER_DUPLEX which indicates duplex mode. Defaults to AUTO.
•AUTO
Auto mode
•FULL
Full mode
•HALF
Half mode
<SPEED>
The parameter type is ETHER_SPEED which indicates Ethernet speed. Defaults to AUTO.
•100_MBPS
100 Mbps
•10_GBPS
10 Gbps
•10_MBPS
10 Mbps
•1_GBPS
1 Gbps
•AUTO
Automatic
<NAME>
Port name. NAME is a string. Defaults to NULL. Maximum length is 32 characters.
<CMDMDE>
Command execution mode. NORM for normal (default) and FRCD for forced. FRCD will override any safeguards that normally reject a request to delete an in service resource.
The parameter type is CMDMDE, which forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied.
•FRCD
Force the system to override a state where the command would normally be denied.
•NORM
Execute the command normally. Do not override any conditions that might make the command fail.
<MACADDR>
MACADDR is a string. Defaults to NULL. Maximum length is 18 characters.
<FREQ>
The parameter type is OPTICAL_WLEN which indicates the optical wavelength.
•1310
Wavelength 1310
•1470
Wavelength 1470
•1490
Wavelength 1490
•1510
Wavelength 1510
•1529.55
Wavelength 1529.55
•1529.94
Wavelength 1529.94
•1530
Wavelength 1530
•1530.33
Wavelength 1530.33
•1530.73
Wavelength 1530.73
•1531.12
Wavelength 1531.12
•1531.51
Wavelength 1531.51
•1531.90
Wavelength 1531.90
•1532.29
Wavelength 1532.29
•1532.68
Wavelength 1532.68
•1533.07
Wavelength 1533.07
•1533.47
Wavelength 1533.47
•1533.86
Wavelength 1533.86
•1534.25
Wavelength 1534.25
•1534.64
Wavelength 1534.64
•1535.04
Wavelength 1535.04
•1535.43
Wavelength 1535.43
•1535.82
Wavelength 1535.82
•1536.22
Wavelength 1536.22
•1536.61
Wavelength 1536.61
•1537
Wavelength 1537
•1537.40
Wavelength 1537.40
•1537.79
Wavelength 1537.79
•1538.19
Wavelength 1538.19
•1538.58
Wavelength 1538.58
•1538.98
Wavelength 1538.98
•1539.37
Wavelength 1539.37
•1539.77
Wavelength 1539.77
•1540.16
Wavelength 1540.16
•1540.56
Wavelength 1540.56
•1540.95
Wavelength 1540.95
•1541.35
Wavelength 1541.35
•1541.75
Wavelength 1541.75
•1542.14
Wavelength 1542.14
•1542.35
Wavelength 1542.35
•1542.54
Wavelength 1542.54
•1542.94
Wavelength 1542.94
•1543.33
Wavelength 1543.33
•1543.73
Wavelength 1543.73
•1544.13
Wavelength 1544.13
•1544.53
Wavelength 1544.53
•1544.92
Wavelength 1544.92
•1545.32
Wavelength 1545.32
•1545.72
Wavelength 1545.72
•1546.12
Wavelength 1546.12
•1546.52
Wavelength 1546.52
•1546.92
Wavelength 1546.92
•1547.32
Wavelength 1547.32
•1547.72
Wavelength 1547.72
•1548.12
Wavelength 1548.12
•1548.51
Wavelength 1548.51
•1548.92
Wavelength 1548.92
•1549.32
Wavelength 1549.32
•1549.71
Wavelength 1549.71
•1550
Wavelength 1500
•1550.12
Wavelength 1550.12
•1550.52
Wavelength 1550.52
•1550.92
Wavelength 1550.92
•1551.32
Wavelength 1551.32
•1551.72
Wavelength 1551.72
•1552.12
Wavelength 1552.12
•1552.52
Wavelength 1552.52
•1552.93
Wavelength 1552.93
•1553.33
Wavelength 1553.33
•1553.73
Wavelength 1553.73
•1554.13
Wavelength 1554.13
•1554.13
Wavelength 1554.13
•1554.94
Wavelength 1554.94
•1555.34
Wavelength 1555.34
•1555.75
Wavelength 1555.75
•1556.15
Wavelength 1556.15
•1556.55
Wavelength 1556.55
•1556.96
Wavelength 1556.96
•1557.36
Wavelength 1557.36
•1557.77
Wavelength 1557.77
•1558.17
Wavelength 1558.17
•1558.58
Wavelength 1558.58
•1558.98
Wavelength 1558.98
•1559.39
Wavelength 1559.39
•1559.79
Wavelength 1559.79
•1560.20
Wavelength 1560.20
•1560.61
Wavelength 1560.61
•1561.01
Wavelength 1561.01
•1561.42
Wavelength 1561.42
•1561.83
Wavelength 1561.83
•1570
Wavelength 1570
•1570.83
Wavelength 1570.83
•1571.24
Wavelength 1571.24
•1571.65
Wavelength 1571.65
•1572.06
Wavelength 1572.06
•1572.48
Wavelength 1572.48
•1572.89
Wavelength 1572.89
•1573.30
Wavelength 1573.30
•1573.71
Wavelength 1573.71
•1574.13
Wavelength 1574.13
•1574.54
Wavelength 1574.54
•1574.95
Wavelength 1574.95
•1575.37
Wavelength 1575.37
•1575.78
Wavelength 1575.78
•1576.20
Wavelength 1576.20
•1576.61
Wavelength 1576.61
•1577.03
Wavelength 1577.03
•1577.44
Wavelength 1577.44
•1577.86
Wavelength 1577.86
•1578.27
Wavelength 1578.27
•1578.69
Wavelength 1578.69
•1579.10
Wavelength 1579.10
•1579.52
Wavelength 1579.52
•1579.93
Wavelength 1579.93
•1580.35
Wavelength 1580.35
•1580.77
Wavelength 1580.77
•1581.18
Wavelength 1581.18
•1581.60
Wavelength 1581.60
•1582.02
Wavelength 1582.02
•1582.44
Wavelength 1582.44
•1582.85
Wavelength 1582.85
•1583.27
Wavelength 1583.27
•1583.69
Wavelength 1583.69
•1584.11
Wavelength 1584.11
•1584.53
Wavelength 1584.53
•1584.95
Wavelength 1584.95
•1585.36
Wavelength 1585.36
•1585.78
Wavelength 1585.78
•1586.20
Wavelength 1586.20
•1586.62
Wavelength 1586.62
•1587.04
Wavelength 1587.04
•1587.46
Wavelength 1587.46
•1587.88
Wavelength 1587.88
•1588.30
Wavelength 1588.30
•1588.73
Wavelength 1588.73
•1589.15
Wavelength 1589.15
•1589.57
Wavelength 1589.57
•1589.99
Wavelength 1589.99
•1590
Wavelength 1590
•1590.41
Wavelength 1590.41
•1590.83
Wavelength 1590.83
•1591.26
Wavelength 1591.26
•1591.68
Wavelength 1591.68
•1592.10
Wavelength 1592.10
•1592.52
Wavelength 1592.52
•1592.95
Wavelength 1592.95
•1593.37
Wavelength 1593.37
•1593.79
Wavelength 1593.79
•1594.22
Wavelength 1594.22
•1594.64
Wavelength 1594.64
•1595.06
Wavelength 1595.06
•1595.49
Wavelength 1595.49
•1596.34
Wavelength 1596.34
•1596.76
Wavelength 1596.76
•1597.19
Wavelength 1597.19
•1597.62
Wavelength 1597.62
•1598.04
Wavelength 1598.04
•1598.47
Wavelength 1598.47
•1598.89
Wavelength 1598.89
•1599.32
Wavelength 1599.32
•1599.75
Wavelength 1599.75
•1600.06
Wavelength 1600.06
•1601.03
Wavelength 1601.03
•1601.46
Wavelength 1601.46
•1601.88
Wavelength 1601.88
•1602.31
Wavelength 1602.31
•1602.74
Wavelength 1602.74
•1603.17
Wavelength 1603.17
•1603.60
Wavelength 1603.60
•1604.03
Wavelength 1604.03
•1610
Wavelength 1610
•USE-TWL1
Use Tunable Wavelength 1
<LOSSB>
The parameter type is REACH which indicates the reach values.
•AUTOPROV
Autoprovisioning
•CX
Reach CX
•DX
Reach DX
•HX
Reach HX
•I1
Reach I1
•IR-1
Reach IR-1
•IR-2
Reach IR-2
•L1
Reach L1
•L2
Reach L2
•L3
Reach L3
•LR-1
Reach LR-1
•LR-2
Reach LR-2
•LR-3
Reach LR-3
•LX
Reach LX
•S1
Reach S1
•S2
Reach S2
•SR
Reach SR
•SR-1
Reach SR-1
•SX
Reach SX
•T
Reach T
•VX
Reach VX
•ZX
Reach ZX
<SOAK>
IS-AINS to IS transition soak time as measured in 15-minute intervals. A value of 4 equals a soak time of 1 hour. The allowable range is 0 to 192 intervals (maximum of 48 hours). SOAK is an integer. Defaults to 32.
<PST>
The primary state. The parameter type is PST, which indicates the current overall service condition of an entity. Defaults to OOS.
•IS
In service
•OOS
Out of service
SST
The secondary state. The parameter type is SST, which provides additional information pertaining to PST and primary state qualifier (PSTQ). Defaults to DSBLD.
•AINS
Automatic in service
•DSBLD
Disabled
•LPBK
Loopback
•MEA
Mismatch of equipment and attributes
•MT
Maintenance mode
•OOG
Out of group
•SWDL
Software downloading
•UAS
Unassigned
•UEQ
Unequipped
11.2 ED-<MOD1FCPAYLOAD>
(Cisco ONS 15454) The Edit 1GFC, 2GFC, or 4GFC (ED-<MODFCPAYLOAD>) command edits the attributes related to the Fibre Channel (FC) facility. The state IS,AINS is not supported on the FC port.
Usage Guidelines
See Table 27-1 for supported modifiers by platform.
Note•The port parameters VIZ, LINKRCVRY, DISTEXTN, AUTODETECTION, LINKCREDITS, and MFS can be edited only if the port state is OOS,MT or OOS,DSBLD.
•The port parameters AUTODETECTION, LINKCREDITS, and MFS can be edited only if distance extension is enabled (set to B2B).
•When 1GFICON and 2GFICON payloads are provisioned, distance extension=B2B is the default and only valid setting. Setting distance extension (using the ED-nGFICON command) to any other setting will be denied with an error message, for example, Provisioning Rules Failed.
CategoryPorts
SecurityProvisioning
Input FormatED-<MOD1FCPAYLOAD>:[<TID>]:<AID>:<CTAG>:::[LINKRCVRY=<LINKRCVRY>],
[DISTEXTN=<DISTEXTN>],[AUTODETECTION=<AUTODETECTION>],
[LINKCREDITS=<LINKCREDITS>],[MFS=<MFS>],[NAME=<NAME>],
[CMDMDE=<CMDMDE>],[SOAK=<SOAK>],[FREQ=<FREQ>],
[LOSSB=<LOSSB>]:[<PST>[,[<SST>]];Input ExampleED-1GFC:CISCO:FAC-6-1:1:::LINKRCVRY=Y,DISTEXTN=NONE,AUTODETECTION=Y,
LINKCREDITS=10,MFS=2148,NAME="FC PORT",CMDMDE=CMDMDE,SOAK=32,
FREQ=1550,LOSSB=LR-1:OOS,MT;Input Parameters
<AID>
Access identifier from the "FACILITY" section.
<LINKRCVRY>
Link recovery. The parameter type is ON_OFF, which disables or enables an attribute.
•N
Disable an attribute.
•Y
Enable an attribute.
<DISTEXTN>
Distance extension. It can be set to Buffer-to-Buffer (B2B) Credit Management state or None.
Note B2B and link recovery are mutually exclusive. You cannot turn on both B2B and link recovery at the same time.
The parameter type is DISTANCE_EXTENSION (distance extension).
•B2B
Buffer to buffer flow control
•NONE
No distance extension
<AUTODETECTION>
Autodetection. Turns autodetection on or off. The parameter type is ON_OFF, which disables or enables an attribute.
•N
Disable an attribute
•Y
Enable an attribute
<LINKCREDITS>
Number of link credits. If autodetection is set to off, the value of the link credits will be used to configure the hardware. LINKCREDITS is an integer.
<MFS>
Maximum frame size. MFS is an integer.
<NAME>
String
<CMDMDE>
Command execution mode, forced or normal. FRCD deletes all the VCG members and member cross-connects of a VCG.
Parameter type is CMDMDE, which forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied.
•FRCD
Force the system to override a state where the command would normally be denied.
•NORM
Execute the command normally. Do not override any conditions that might make the command fail.
<SOAK>
OOS-AINS to IS transition soak time as measured in 15-minute intervals. A value of 4 equals a soak time of 1 hour. The allowable range is 0 to 192 intervals (maximum of 48 hours). SOAK is an integer.
<FREQ>
The parameter type is OPTICAL_WLEN, which is the optical wavelength.
•1310
Wavelength 1310
•1470
Wavelength 1470
•1490
Wavelength 1490
•1510
Wavelength 1510
•1529.55
Wavelength 1529.55
•1529.94
Wavelength 1529.94
•1530
Wavelength 1530
•1530.33
Wavelength 1530.33
•1530.73
Wavelength 1530.73
•1531.12
Wavelength 1531.12
•1531.51
Wavelength 1531.51
•1531.90
Wavelength 1531.90
•1532.29
Wavelength 1532.29
•1532.68
Wavelength 1532.68
•1533.07
Wavelength 1533.07
•1533.47
Wavelength 1533.47
•1533.86
Wavelength 1533.86
•1534.25
Wavelength 1534.25
•1534.64
Wavelength 1534.64
•1535.04
Wavelength 1535.04
•1535.43
Wavelength 1535.43
•1535.82
Wavelength 1535.82
•1536.22
Wavelength 1536.22
•1536.61
Wavelength 1536.61
•1537
Wavelength 1537
•1537.40
Wavelength 1537.40
•1537.79
Wavelength 1537.79
•1538.19
Wavelength 1538.19
•1538.58
Wavelength 1538.58
•1538.98
Wavelength 1538.98
•1539.37
Wavelength 1539.37
•1539.77
Wavelength 1539.77
•1540.16
Wavelength 1540.16
•1540.56
Wavelength 1540.56
•1540.95
Wavelength 1540.95
•1541.35
Wavelength 1541.35
•1541.75
Wavelength 1541.75
•1542.14
Wavelength 1542.14
•1542.35
Wavelength 1542.35
•1542.54
Wavelength 1542.54
•1542.94
Wavelength 1542.94
•1543.33
Wavelength 1543.33
•1543.73
Wavelength 1543.73
•1544.13
Wavelength 1544.13
•1544.53
Wavelength 1544.53
•1544.92
Wavelength 1544.92
•1545.32
Wavelength 1545.32
•1545.72
Wavelength 1545.72
•1546.12
Wavelength 1546.12
•1546.52
Wavelength 1546.52
•1546.92
Wavelength 1546.92
•1547.32
Wavelength 1547.32
•1547.72
Wavelength 1547.72
•1548.12
Wavelength 1548.12
•1548.51
Wavelength 1548.51
•1548.92
Wavelength 1548.92
•1549.32
Wavelength 1549.32
•1549.71
Wavelength 1549.71
•1550
Wavelength 1500
•1550.12
Wavelength 1550.12
•1550.52
Wavelength 1550.52
•1550.92
Wavelength 1550.92
•1551.32
Wavelength 1551.32
•1551.72
Wavelength 1551.72
•1552.12
Wavelength 1552.12
•1552.52
Wavelength 1552.52
•1552.93
Wavelength 1552.93
•1553.33
Wavelength 1553.33
•1553.73
Wavelength 1553.73
•1554.13
Wavelength 1554.13
•1554.13
Wavelength 1554.13
•1554.94
Wavelength 1554.94
•1555.34
Wavelength 1555.34
•1555.75
Wavelength 1555.75
•1556.15
Wavelength 1556.15
•1556.55
Wavelength 1556.55
•1556.96
Wavelength 1556.96
•1557.36
Wavelength 1557.36
•1557.77
Wavelength 1557.77
•1558.17
Wavelength 1558.17
•1558.58
Wavelength 1558.58
•1558.98
Wavelength 1558.98
•1559.39
Wavelength 1559.39
•1559.79
Wavelength 1559.79
•1560.20
Wavelength 1560.20
•1560.61
Wavelength 1560.61
•1561.01
Wavelength 1561.01
•1561.42
Wavelength 1561.42
•1561.83
Wavelength 1561.83
•1570
Wavelength 1570
•1570.83
Wavelength 1570.83
•1571.24
Wavelength 1571.24
•1571.65
Wavelength 1571.65
•1572.06
Wavelength 1572.06
•1572.48
Wavelength 1572.48
•1572.89
Wavelength 1572.89
•1573.30
Wavelength 1573.30
•1573.71
Wavelength 1573.71
•1574.13
Wavelength 1574.13
•1574.54
Wavelength 1574.54
•1574.95
Wavelength 1574.95
•1575.37
Wavelength 1575.37
•1575.78
Wavelength 1575.78
•1576.20
Wavelength 1576.20
•1576.61
Wavelength 1576.61
•1577.03
Wavelength 1577.03
•1577.44
Wavelength 1577.44
•1577.86
Wavelength 1577.86
•1578.27
Wavelength 1578.27
•1578.69
Wavelength 1578.69
•1579.10
Wavelength 1579.10
•1579.52
Wavelength 1579.52
•1579.93
Wavelength 1579.93
•1580.35
Wavelength 1580.35
•1580.77
Wavelength 1580.77
•1581.18
Wavelength 1581.18
•1581.60
Wavelength 1581.60
•1582.02
Wavelength 1582.02
•1582.44
Wavelength 1582.44
•1582.85
Wavelength 1582.85
•1583.27
Wavelength 1583.27
•1583.69
Wavelength 1583.69
•1584.11
Wavelength 1584.11
•1584.53
Wavelength 1584.53
•1584.95
Wavelength 1584.95
•1585.36
Wavelength 1585.36
•1585.78
Wavelength 1585.78
•1586.20
Wavelength 1586.20
•1586.62
Wavelength 1586.62
•1587.04
Wavelength 1587.04
•1587.46
Wavelength 1587.46
•1587.88
Wavelength 1587.88
•1588.30
Wavelength 1588.30
•1588.73
Wavelength 1588.73
•1589.15
Wavelength 1589.15
•1589.57
Wavelength 1589.57
•1589.99
Wavelength 1589.99
•1590
Wavelength 1590
•1590.41
Wavelength 1590.41
•1590.83
Wavelength 1590.83
•1591.26
Wavelength 1591.26
•1591.68
Wavelength 1591.68
•1592.10
Wavelength 1592.10
•1592.52
Wavelength 1592.52
•1592.95
Wavelength 1592.95
•1593.37
Wavelength 1593.37
•1593.79
Wavelength 1593.79
•1594.22
Wavelength 1594.22
•1594.64
Wavelength 1594.64
•1595.06
Wavelength 1595.06
•1595.49
Wavelength 1595.49
•1596.34
Wavelength 1596.34
•1596.76
Wavelength 1596.76
•1597.19
Wavelength 1597.19
•1597.62
Wavelength 1597.62
•1598.04
Wavelength 1598.04
•1598.47
Wavelength 1598.47
•1598.89
Wavelength 1598.89
•1599.32
Wavelength 1599.32
•1599.75
Wavelength 1599.75
•1600.06
Wavelength 1600.06
•1601.03
Wavelength 1601.03
•1601.46
Wavelength 1601.46
•1601.88
Wavelength 1601.88
•1602.31
Wavelength 1602.31
•1602.74
Wavelength 1602.74
•1603.17
Wavelength 1603.17
•1603.60
Wavelength 1603.60
•1604.03
Wavelength 1604.03
•1610
Wavelength 1610
•USE-TWL1
Use Tunable Wavelength 1
<LOSSB>
the parameter type is REACH, which is the reach value.
•AUTOPROV
Autoprovisioning
•CX
Reach CX
•DX
Reach DX
•HX
Reach HX
•I1
Reach I1
•IR-1
Reach IR-1
•IR-2
Reach IR-2
•L1
Reach L1
•L2
Reach L2
•L3
Reach L3
•LR-1
Reach LR-1
•LR-2
Reach LR-2
•LR-3
Reach LR-3
•LX
Reach LX
•S1
Reach S1
•S2
Reach S2
•SR
Reach SR
•SR-1
Reach SR-1
•SX
Reach SX
•T
Reach T
•VX
Reach VX
•ZX
Reach ZX
<PST>
Primary state. the parameter type is PST, which indicates the current overall service condition of an entity.
•IS
In service
•OOS
Out of service
<SST>
Secondary state. The parameter type is SST, which provides additional information pertaining to PST and PSTQ.
•AINS
Automatic in service
•DSBLD
Disabled
•LPBK
Loopback
•MEA
Mismatch of equipment and attributes
•MT
Maintenance mode
•OOG
Out of group
•SWDL
Software downloading
•UAS
Unassigned
•UEQ
Unequipped
11.3 ED-<MOD1FICONPAYLOAD>
(Cisco ONS 15454) The Edit 1GFICON, 2GFICON, or 4GFICON (ED-<MOD1FICONPAYLOAD>) command edits the attributes related with the fiber connectivity (FICON) payload facility. The state IS,AINS is not supported on the FICON port.
Usage Guidelines
See Table 27-1 for supported modifiers by platform.
CategoryPorts
SecurityProvisioning
Input FormatED-<MOD1FICONPAYLOAD>:[<TID>]:<AID>:<CTAG>:::[LINKRCVRY=<LINKRCVRY>],
[DISTEXTN=<DISTEXTN>],[AUTODETECTION=<AUTODETECTION>],
[LINKCREDITS=<LINKCREDITS>],[MFS=<MFS>],[NAME=<NAME>],
[CMDMDE=<CMDMDE>],[SOAK=<SOAK>],[FREQ=<FREQ>],
[LOSSB=<LOSSB>]:[<PST>[,<SST>]];Input ExampleED-1GFICON:CISCO:FAC-6-1:1:::LINKRCVRY=Y,DISTEXTN=NONE,AUTODETECTION=Y,
LINKCREDITS=10,MFS=2148,NAME="FC PORT",CMDMDE=CMDMDE,SOAK=32,FREQ=1550,
LOSSB=LR-1:OOS,MT;Input Parameters
<AID>
Access identifier from the "FACILITY" section.
<LINKRCVRY>
Link recovery. The parameter type is ON_OFF, which disables or enables an attribute.
•N
Disable an attribute
•Y
Enable an attribute
<DISTEXTN>
Distance extension. It can be set to B2B Credit Management state or None.
Note B2B and link recovery are mutually exclusive. You cannot turn on both B2B and link recovery at the same time.
The parameter type is DISTANCE_EXTENSION (distance extension).
•B2B
Buffer to buffer flow control
•NONE
No distance extension
<AUTODETECTION>
Autodetection. Turns autodetection on or off. The parameter type is ON_OFF, which disables or enables an attribute.
•N
Disable an attribute
•Y
Enable an attribute
<LINKCREDITS>
Number of link credits. If autodetection is set to off the value of the link credits will be used to configure the hardware. LINKCREDITS is an integer.
<MFS>
Maximum frame size. MFS is an integer.
<NAME>
String
<CMDMDE>
Command execution mode, forced or normal. FRCD deletes all the VCG members and member cross-connects of a VCG.
The parameter type is CMDMDE, which forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied.
•FRCD
Force the system to override a state where the command would normally be denied.
•NORM
Execute the command normally. Do not override any conditions that might make the command fail.
<SOAK>
OOS-AINS to IS transition soak time as measured in 15-minute intervals. A value of 4 equals a soak time of 1 hour. The allowable range is 0 to 192 intervals (maximum of 48 hours). SOAK is an integer.
<FREQ>
The parameter type is OPTICAL_WLEN (optical wavelength).
•1310
Wavelength 1310
•1470
Wavelength 1470
•1490
Wavelength 1490
•1510
Wavelength 1510
•1529.55
Wavelength 1529.55
•1529.94
Wavelength 1529.94
•1530
Wavelength 1530
•1530.33
Wavelength 1530.33
•1530.73
Wavelength 1530.73
•1531.12
Wavelength 1531.12
•1531.51
Wavelength 1531.51
•1531.90
Wavelength 1531.90
•1532.29
Wavelength 1532.29
•1532.68
Wavelength 1532.68
•1533.07
Wavelength 1533.07
•1533.47
Wavelength 1533.47
•1533.86
Wavelength 1533.86
•1534.25
Wavelength 1534.25
•1534.64
Wavelength 1534.64
•1535.04
Wavelength 1535.04
•1535.43
Wavelength 1535.43
•1535.82
Wavelength 1535.82
•1536.22
Wavelength 1536.22
•1536.61
Wavelength 1536.61
•1537
Wavelength 1537
•1537.40
Wavelength 1537.40
•1537.79
Wavelength 1537.79
•1538.19
Wavelength 1538.19
•1538.58
Wavelength 1538.58
•1538.98
Wavelength 1538.98
•1539.37
Wavelength 1539.37
•1539.77
Wavelength 1539.77
•1540.16
Wavelength 1540.16
•1540.56
Wavelength 1540.56
•1540.95
Wavelength 1540.95
•1541.35
Wavelength 1541.35
•1541.75
Wavelength 1541.75
•1542.14
Wavelength 1542.14
•1542.35
Wavelength 1542.35
•1542.54
Wavelength 1542.54
•1542.94
Wavelength 1542.94
•1543.33
Wavelength 1543.33
•1543.73
Wavelength 1543.73
•1544.13
Wavelength 1544.13
•1544.53
Wavelength 1544.53
•1544.92
Wavelength 1544.92
•1545.32
Wavelength 1545.32
•1545.72
Wavelength 1545.72
•1546.12
Wavelength 1546.12
•1546.52
Wavelength 1546.52
•1546.92
Wavelength 1546.92
•1547.32
Wavelength 1547.32
•1547.72
Wavelength 1547.72
•1548.12
Wavelength 1548.12
•1548.51
Wavelength 1548.51
•1548.92
Wavelength 1548.92
•1549.32
Wavelength 1549.32
•1549.71
Wavelength 1549.71
•1550
Wavelength 1500
•1550.12
Wavelength 1550.12
•1550.52
Wavelength 1550.52
•1550.92
Wavelength 1550.92
•1551.32
Wavelength 1551.32
•1551.72
Wavelength 1551.72
•1552.12
Wavelength 1552.12
•1552.52
Wavelength 1552.52
•1552.93
Wavelength 1552.93
•1553.33
Wavelength 1553.33
•1553.73
Wavelength 1553.73
•1554.13
Wavelength 1554.13
•1554.13
Wavelength 1554.13
•1554.94
Wavelength 1554.94
•1555.34
Wavelength 1555.34
•1555.75
Wavelength 1555.75
•1556.15
Wavelength 1556.15
•1556.55
Wavelength 1556.55
•1556.96
Wavelength 1556.96
•1557.36
Wavelength 1557.36
•1557.77
Wavelength 1557.77
•1558.17
Wavelength 1558.17
•1558.58
Wavelength 1558.58
•1558.98
Wavelength 1558.98
•1559.39
Wavelength 1559.39
•1559.79
Wavelength 1559.79
•1560.20
Wavelength 1560.20
•1560.61
Wavelength 1560.61
•1561.01
Wavelength 1561.01
•1561.42
Wavelength 1561.42
•1561.83
Wavelength 1561.83
•1570
Wavelength 1570
•1570.83
Wavelength 1570.83
•1571.24
Wavelength 1571.24
•1571.65
Wavelength 1571.65
•1572.06
Wavelength 1572.06
•1572.48
Wavelength 1572.48
•1572.89
Wavelength 1572.89
•1573.30
Wavelength 1573.30
•1573.71
Wavelength 1573.71
•1574.13
Wavelength 1574.13
•1574.54
Wavelength 1574.54
•1574.95
Wavelength 1574.95
•1575.37
Wavelength 1575.37
•1575.78
Wavelength 1575.78
•1576.20
Wavelength 1576.20
•1576.61
Wavelength 1576.61
•1577.03
Wavelength 1577.03
•1577.44
Wavelength 1577.44
•1577.86
Wavelength 1577.86
•1578.27
Wavelength 1578.27
•1578.69
Wavelength 1578.69
•1579.10
Wavelength 1579.10
•1579.52
Wavelength 1579.52
•1579.93
Wavelength 1579.93
•1580.35
Wavelength 1580.35
•1580.77
Wavelength 1580.77
•1581.18
Wavelength 1581.18
•1581.60
Wavelength 1581.60
•1582.02
Wavelength 1582.02
•1582.44
Wavelength 1582.44
•1582.85
Wavelength 1582.85
•1583.27
Wavelength 1583.27
•1583.69
Wavelength 1583.69
•1584.11
Wavelength 1584.11
•1584.53
Wavelength 1584.53
•1584.95
Wavelength 1584.95
•1585.36
Wavelength 1585.36
•1585.78
Wavelength 1585.78
•1586.20
Wavelength 1586.20
•1586.62
Wavelength 1586.62
•1587.04
Wavelength 1587.04
•1587.46
Wavelength 1587.46
•1587.88
Wavelength 1587.88
•1588.30
Wavelength 1588.30
•1588.73
Wavelength 1588.73
•1589.15
Wavelength 1589.15
•1589.57
Wavelength 1589.57
•1589.99
Wavelength 1589.99
•1590
Wavelength 1590
•1590.41
Wavelength 1590.41
•1590.83
Wavelength 1590.83
•1591.26
Wavelength 1591.26
•1591.68
Wavelength 1591.68
•1592.10
Wavelength 1592.10
•1592.52
Wavelength 1592.52
•1592.95
Wavelength 1592.95
•1593.37
Wavelength 1593.37
•1593.79
Wavelength 1593.79
•1594.22
Wavelength 1594.22
•1594.64
Wavelength 1594.64
•1595.06
Wavelength 1595.06
•1595.49
Wavelength 1595.49
•1596.34
Wavelength 1596.34
•1596.76
Wavelength 1596.76
•1597.19
Wavelength 1597.19
•1597.62
Wavelength 1597.62
•1598.04
Wavelength 1598.04
•1598.47
Wavelength 1598.47
•1598.89
Wavelength 1598.89
•1599.32
Wavelength 1599.32
•1599.75
Wavelength 1599.75
•1600.06
Wavelength 1600.06
•1601.03
Wavelength 1601.03
•1601.46
Wavelength 1601.46
•1601.88
Wavelength 1601.88
•1602.31
Wavelength 1602.31
•1602.74
Wavelength 1602.74
•1603.17
Wavelength 1603.17
•1603.60
Wavelength 1603.60
•1604.03
Wavelength 1604.03
•1610
Wavelength 1610
•USE-TWL1
Use Tunable Wavelength 1
<LOSSB>
The parameter type is REACH, which is the reach value.
•AUTOPROV
Autoprovisioning
•CX
Reach CX
•DX
Reach DX
•HX
Reach HX
•I1
Reach I1
•IR-1
Reach IR-1
•IR-2
Reach IR-2
•L1
Reach L1
•L2
Reach L2
•L3
Reach L3
•LR-1
Reach LR-1
•LR-2
Reach LR-2
•LR-3
Reach LR-3
•LX
Reach LX
•S1
Reach S1
•S2
Reach S2
•SR
Reach SR
•SR-1
Reach SR-1
•SX
Reach SX
•T
Reach T
•VX
Reach VX
•ZX
Reach ZX
<PST>
Primary state. The parameter type is PST, which indicates the current overall service condition of an entity.
•IS
In service
•OOS
Out of service
<SST>
Secondary state. The parameter type is SST, which provides additional information pertaining to PST and PSTQ.
•AINS
Automatic in service
•DSBLD
Disabled
•LPBK
Loopback
•MEA
Mismatch of equipment and attributes
•MT
Maintenance mode
•OOG
Out of group
•SWDL
Software downloading
•UAS
Unassigned
•UEQ
Unequipped
11.4 ED-<MOD2DWDMPAYLOAD>
(Cisco ONS 15454) The Edit 10GFC, 10GIGE, 1GFC, 1GFICON, 1GISC3, 2GFC, 2GFICON, 2GISC3, 4GFC, 4GFICON, D1VIDEO, DV6000, ETRCLO, GIGE, HDTV, ISC1, ISC3, or PASSTHRU (ED-<MOD2DWDMPAYLOAD>) command edits the operating parameters for a dense wavelength division multiplexing (DWDM) client facility.
Usage Guidelines
See Table 27-1 for supported modifiers by platform.
CategoryDWDM
SecurityProvisioning
Input FormatED-<MOD2DWDMPAYLOAD>:[<TID>]:<AID>:<CTAG>:::[NAME=<NAME>],
[CMDMDE=<CMDMDE>],[FREQ=<FREQ>],[LOSSB=<LOSSB>]:[<PST>[,<SST>]];Input ExampleED-HDTV::FAC-1-1:1:::NAME="PORTNAME",CMDMDE=CMDMDE,FREQ=1550,
LOSSB=LR-1:IS,AINS;Input Parameters
<AID>
Access identifier from the "FACILITY" section.
<LINKCREDITS>
Number of link credits. If autodetection is set to off the value of the link credits will be used to configure the hardware. LINKCREDITS is an integer.
<NAME>
String
<CMDMDE>
Command execution mode, forced or normal. FRCD deletes all the VCG members and member cross-connects of a VCG.
The parameter type is CMDMDE, which forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied.
•FRCD
Force the system to override a state where the command would normally be denied.
•NORM
Execute the command normally. Do not override any conditions that might make the command fail.
<FREQ>
The parameter type is OPTICAL_WLEN (optical wavelength).
•1310
Wavelength 1310
•1470
Wavelength 1470
•1490
Wavelength 1490
•1510
Wavelength 1510
•1529.55
Wavelength 1529.55
•1529.94
Wavelength 1529.94
•1530
Wavelength 1530
•1530.33
Wavelength 1530.33
•1530.73
Wavelength 1530.73
•1531.12
Wavelength 1531.12
•1531.51
Wavelength 1531.51
•1531.90
Wavelength 1531.90
•1532.29
Wavelength 1532.29
•1532.68
Wavelength 1532.68
•1533.07
Wavelength 1533.07
•1533.47
Wavelength 1533.47
•1533.86
Wavelength 1533.86
•1534.25
Wavelength 1534.25
•1534.64
Wavelength 1534.64
•1535.04
Wavelength 1535.04
•1535.43
Wavelength 1535.43
•1535.82
Wavelength 1535.82
•1536.22
Wavelength 1536.22
•1536.61
Wavelength 1536.61
•1537
Wavelength 1537
•1537.40
Wavelength 1537.40
•1537.79
Wavelength 1537.79
•1538.19
Wavelength 1538.19
•1538.58
Wavelength 1538.58
•1538.98
Wavelength 1538.98
•1539.37
Wavelength 1539.37
•1539.77
Wavelength 1539.77
•1540.16
Wavelength 1540.16
•1540.56
Wavelength 1540.56
•1540.95
Wavelength 1540.95
•1541.35
Wavelength 1541.35
•1541.75
Wavelength 1541.75
•1542.14
Wavelength 1542.14
•1542.35
Wavelength 1542.35
•1542.54
Wavelength 1542.54
•1542.94
Wavelength 1542.94
•1543.33
Wavelength 1543.33
•1543.73
Wavelength 1543.73
•1544.13
Wavelength 1544.13
•1544.53
Wavelength 1544.53
•1544.92
Wavelength 1544.92
•1545.32
Wavelength 1545.32
•1545.72
Wavelength 1545.72
•1546.12
Wavelength 1546.12
•1546.52
Wavelength 1546.52
•1546.92
Wavelength 1546.92
•1547.32
Wavelength 1547.32
•1547.72
Wavelength 1547.72
•1548.12
Wavelength 1548.12
•1548.51
Wavelength 1548.51
•1548.92
Wavelength 1548.92
•1549.32
Wavelength 1549.32
•1549.71
Wavelength 1549.71
•1550
Wavelength 1500
•1550.12
Wavelength 1550.12
•1550.52
Wavelength 1550.52
•1550.92
Wavelength 1550.92
•1551.32
Wavelength 1551.32
•1551.72
Wavelength 1551.72
•1552.12
Wavelength 1552.12
•1552.52
Wavelength 1552.52
•1552.93
Wavelength 1552.93
•1553.33
Wavelength 1553.33
•1553.73
Wavelength 1553.73
•1554.13
Wavelength 1554.13
•1554.13
Wavelength 1554.13
•1554.94
Wavelength 1554.94
•1555.34
Wavelength 1555.34
•1555.75
Wavelength 1555.75
•1556.15
Wavelength 1556.15
•1556.55
Wavelength 1556.55
•1556.96
Wavelength 1556.96
•1557.36
Wavelength 1557.36
•1557.77
Wavelength 1557.77
•1558.17
Wavelength 1558.17
•1558.58
Wavelength 1558.58
•1558.98
Wavelength 1558.98
•1559.39
Wavelength 1559.39
•1559.79
Wavelength 1559.79
•1560.20
Wavelength 1560.20
•1560.61
Wavelength 1560.61
•1561.01
Wavelength 1561.01
•1561.42
Wavelength 1561.42
•1561.83
Wavelength 1561.83
•1570
Wavelength 1570
•1570.83
Wavelength 1570.83
•1571.24
Wavelength 1571.24
•1571.65
Wavelength 1571.65
•1572.06
Wavelength 1572.06
•1572.48
Wavelength 1572.48
•1572.89
Wavelength 1572.89
•1573.30
Wavelength 1573.30
•1573.71
Wavelength 1573.71
•1574.13
Wavelength 1574.13
•1574.54
Wavelength 1574.54
•1574.95
Wavelength 1574.95
•1575.37
Wavelength 1575.37
•1575.78
Wavelength 1575.78
•1576.20
Wavelength 1576.20
•1576.61
Wavelength 1576.61
•1577.03
Wavelength 1577.03
•1577.44
Wavelength 1577.44
•1577.86
Wavelength 1577.86
•1578.27
Wavelength 1578.27
•1578.69
Wavelength 1578.69
•1579.10
Wavelength 1579.10
•1579.52
Wavelength 1579.52
•1579.93
Wavelength 1579.93
•1580.35
Wavelength 1580.35
•1580.77
Wavelength 1580.77
•1581.18
Wavelength 1581.18
•1581.60
Wavelength 1581.60
•1582.02
Wavelength 1582.02
•1582.44
Wavelength 1582.44
•1582.85
Wavelength 1582.85
•1583.27
Wavelength 1583.27
•1583.69
Wavelength 1583.69
•1584.11
Wavelength 1584.11
•1584.53
Wavelength 1584.53
•1584.95
Wavelength 1584.95
•1585.36
Wavelength 1585.36
•1585.78
Wavelength 1585.78
•1586.20
Wavelength 1586.20
•1586.62
Wavelength 1586.62
•1587.04
Wavelength 1587.04
•1587.46
Wavelength 1587.46
•1587.88
Wavelength 1587.88
•1588.30
Wavelength 1588.30
•1588.73
Wavelength 1588.73
•1589.15
Wavelength 1589.15
•1589.57
Wavelength 1589.57
•1589.99
Wavelength 1589.99
•1590
Wavelength 1590
•1590.41
Wavelength 1590.41
•1590.83
Wavelength 1590.83
•1591.26
Wavelength 1591.26
•1591.68
Wavelength 1591.68
•1592.10
Wavelength 1592.10
•1592.52
Wavelength 1592.52
•1592.95
Wavelength 1592.95
•1593.37
Wavelength 1593.37
•1593.79
Wavelength 1593.79
•1594.22
Wavelength 1594.22
•1594.64
Wavelength 1594.64
•1595.06
Wavelength 1595.06
•1595.49
Wavelength 1595.49
•1596.34
Wavelength 1596.34
•1596.76
Wavelength 1596.76
•1597.19
Wavelength 1597.19
•1597.62
Wavelength 1597.62
•1598.04
Wavelength 1598.04
•1598.47
Wavelength 1598.47
•1598.89
Wavelength 1598.89
•1599.32
Wavelength 1599.32
•1599.75
Wavelength 1599.75
•1600.06
Wavelength 1600.06
•1601.03
Wavelength 1601.03
•1601.46
Wavelength 1601.46
•1601.88
Wavelength 1601.88
•1602.31
Wavelength 1602.31
•1602.74
Wavelength 1602.74
•1603.17
Wavelength 1603.17
•1603.60
Wavelength 1603.60
•1604.03
Wavelength 1604.03
•1610
Wavelength 1610
•USE-TWL1
Use Tunable Wavelength 1
<LOSSB>
the parameter type is REACH, which is the reach value.
•AUTOPROV
Autoprovisioning
•CX
Reach CX
•DX
Reach DX
•HX
Reach HX
•I1
Reach I1
•IR-1
Reach IR-1
•IR-2
Reach IR-2
•L1
Reach L1
•L2
Reach L2
•L3
Reach L3
•LR-1
Reach LR-1
•LR-2
Reach LR-2
•LR-3
Reach LR-3
•LX
Reach LX
•S1
Reach S1
•S2
Reach S2
•SR
Reach SR
•SR-1
Reach SR-1
•SX
Reach SX
•T
Reach T
•VX
Reach VX
•ZX
Reach ZX
<PST>
Primary state. The parameter type is PST, which indicates the current overall service condition of an entity.
•IS
In service
•OOS
Out of service
<SST>
Secondary state. The parameter type is SST, which provides additional information pertaining to PST and PSTQ.
•AINS
Automatic in service
•DSBLD
Disabled
•LPBK
Loopback
•MEA
Mismatch of equipment and attributes
•MT
Maintenance mode
•OOG
Out of group
•SWDL
Software downloading
•UAS
Unassigned
•UEQ
Unequipped
11.5 ED-<MOD_PATH>
(Cisco ONS 15454, ONS 15327, ONS 15310-CL, ONS 15310-MA, ONS 15600) The Edit STS1, STS12C, STS18C, STS192C, STS24C, STS36C, STS3C, STS48C, STS6C, STS9C, VC12, VC3, VT1, or VT2 (ED-<MOD_PATH>) command edits the attributes associated with synchronous transport signal (STS) and Virtual Tributary (VT) paths.
Usage Guidelines
The SFBER, SDBER, RVRTV, and RVTM parameters only apply to unidirectional path switched rings (path protection configurations) at the STS path level and ONS 15310_CL and ONS 15454 VT paths.
SFBER and SDBER also apply to the VT path level on the ONS 15310-CL and ONS 15454 when the ONS 15454 has an XC-VXC-10G card.
SWPDIP does not apply to the VT path level (VT1 and VT2).
The path trace message is a 64 character string including the terminating CR (carriage return) and LF (line feed) that is transported in the J1 byte of the SONET STS Path overhead. Both the EXPTRC and TRC string can be provisioned by user with up to 62 character string.
The EXPTRC indicates that the contents of the expected incoming path trace are provisioned by the user. The TRC indicates the contents of the outgoing path trace message. The INCTRC indicates the contents of the incoming path trace message.
Path trace has three modes: OFF, MANUAL, and AUTO. The path trace mode defaults to OFF. The MANUAL mode performs the comparison of the received string with the user-entered expected string. The AUTO mode performs the comparison of the present received string with an expected string that is set to a previously received string. If there is a mismatch, a TIM-P alarm is raised. When the path trace is in OFF mode, there is no path trace processing, and all of the alarm and state conditions are reset.
The TACC parameter edits an existing single STS or VT and changes it to a test access point. When an editing command on TACC is executed, it assigns the STS or VT for the first two-way connection and STS+1 as the second two-way connection. For single facility access digroup (FAD) test access, only a single STS/VT is used for the test access point (TAP) creation. For more information on TACC, refer to the Cisco ONS SONET TL1 Reference Guide.
J1 is implemented on the DS1/DS1N, DS3E/DS3NE, DS3XM, EC1, OC3, OC12-4, OC48AS, and OC192 cards.
DS3/DS3N, OC12, OC48, E100, and E1000 cards do not support path trace.
DS1/DS1N, DS3E/DS3NE, and DS3XM support both TRC and EXPTRC in the ED-STS-PATH command.
EC1, OC3, OC48AS, and OC192 only support EXPTRC in the ED-STS-PATH command.
Note Each TL1 command must be less than or equal to 255 characters. Any command larger than 255 characters must be split into multiple commands. For example, if you use the ED-<MOD_PATH> command to edit the J1 EXPTRC/TRC message, path protection attributes, and TACC attributes and the command exceeds 255 characters, the command will not be processed. You must use multiple ED-<MOD_PATH> commands instead.
The following actions will produce error messages:
•Sending this command to edit SFBER, SDBER, RVRTV, or RVTM for the non-path protection STS path.
•Sending this command to edit the EXPTRC string with the AUTO path trace mode (TRCMODE=AUTO).
•Sending this command to edit TRC on any card other than DS3(N)E, DS1(N), and DS3XM cards, will return the "TRC-not allowed for monitor paths. Incorrect card type" error message.
•Sending this command to edit both TACC and any other attribute(s) will return the "Parameters Not compatible" error message.
•Sending this command to edit TACC on an AID with cross-connections will return the "STS in Use" error message.
Note•TACC creation will be denied on the protect ports/cards for 1:1, 1:N, and 1+1 protection.
•The VFAC AID is only valid on slots containing an ML-Series card. TACC is not supported for the ML-Series cards.
•After bidirectional line switched ring (BLSR) switching, provisioning of the J1 trace string or trace mode is not allowed on the protection path.
•TACC creation is allowed on protection channel access (PCA) for two-fiber and four-fiber BLSR.
•TACC is not supported on G1000, MXP_2.5G_10G, TXP_MR_10G, ML1000-2, and ML100T-12 cards.
•HOLDOFFTIMER is not specific to a path. It is applicable to the path protection selector. If HOLDOFFTIMER is changed on one path associated with the selector, the HOLDOFFTIMER of the other path associated with the same selector is also changed.
•The test set physical connection set up through ED-T3/DS1/STS1/VT1 of the DS3XM-12 card is only allowed on the physical front ports (PORTED ports, Ports 1 to 12), which are the monitoring ports.
–The monitoring test access ports follow the common rules for the other cards. For example, with an ED-T3 command on Port 2 (FAC-6-2) that has a TACC number (8), the next port, Port 3 (FAC-6-3) is used as the monitoring point also. The RTRV-T3 on both Port 2 and Port 3 return the same TACC number (8) used to monitor the cross-connection end (A-B). The last port (Port 12) is not allowed to set up a physical connection with the test set because there is no next available port to be the monitoring port.
–The TACC disconnection (DISC-TACC) and the test access mode change command (CHG-TACC) follow the same requirement as in the previous step, but it is applied on the ported ports of the DS3XM-12 card.
–The test access connection setup command (CONN-TACC) has monitored points, which can be portless ports. This command is applied on both ported and portless ports of the DS3XM-12 card.
•If the entity has a TACC connection, the entity is not allowed to have ported or portless STS/VT cross-connection (or circuit) provisioning on the DS3XM-12 card.
•Test access is not supported on the ONS 15310-CL.
•J2 path trace is not supported on the 15310-CL-CTX card of the ONS 15310-CL, however the CE-100T-8 or ML-100T-8 card provisioned in mapper mode does allow J2 provisioning.
•The cross-connects on the DS3i-N-12 card will be STS3c width, but the individual STS 1s within the 3C will be accessible. To edit the path attributes, use the ED-STS1 command with the FAC AID.
For TACC creation, use the ED-STS3C command because the TACC path width (like the cross-connect) has to be 3C on the DS3i-N-12 card. In this case, you are creating a new entity (TAP) on the DS3i-N-12 card that has to be of 3C width. On the DS3i-N-12 card, the ED0STS command can be used either with STS1 or STS3C depending on the parameter to be modified.
•For the selector path on a BLSR, the SWPDIP is not editable and is always in the ON state. If you attempt to edit SWPDIP (for the selector path on a BLSR), an error message will be returned.
•You can create an STS1 or VT1.5 single TAP on the DS3XM-12 card's last ported port (12) if the bandwidth is available on that port.
•Optical ports do not support MAN and AUTO trace mode because they are not capable of raising AIS on TIM-P. Use the AUTO-NO-AIS or MAN-NO-AIS trace mode on optical ports.
•Sending the ED-VT1/VT2 commands over ONS 15454 path protection paths to edit SFBER or SDBER (when the ONS 15454 does not have an XC-VXC-10G cross-connect) will return the "Invalid Operation For The XCON" error message.
•Sending the ED-VT1/VT2 commands to edit SDBER with 1E-9 will return the "Out Of Range" error message.
•On the ONS 15310-MA, J2 path trace is supported on DS1 ports only. J2 path trace is not supported on ONS 15310-MA OCn ports and EC1 ports.
CategoryPaths
SecurityProvisioning
Input FormatED-<MOD_PATH>:[<TID>]:<AID>:<CTAG>:::[SFBER=<SFBER>],[SDBER=<SDBER>],
[RVRTV=<RVRTV>],[RVTM=<RVTM>],[SWPDIP=<SWPDIP>],
[HOLDOFFTIMER=<HOLDOFFTIMER>],[EXPTRC=<EXPTRC>],[TRC=<TRC>],
[TRCMODE=<TRCMODE>],[TRCFORMAT=<TRCFORMAT>][TACC=<TACC>],
[TAPTYPE=<TAPTYPE>],[CMDMDE=<CMDMDE>]:[<PST>[,<SST>]];Input ExampleED-STS3C:FERNDALE:STS-2-1-4:115:::SFBER=1E-3,SDBER=1E-5,RVRTV=Y,RVTM=1.0,
SWPDIP=Y,HOLDOFFTIMER=2000,EXPTRC="EXPTRCSTRING",TRC="TRCSTRING",
TRCMODE=OFF,TRCFORMAT=64-BYTE,TACC=8,TAPTYPE=SINGLE,
CMDMDE=CMDMDE:IS,AINS;Input Parameters
<AID>
Access identifier from the "CrossConnectId1" section.
<SFBER>
Signal failure threshold. Applies only to path protection. Applies to STS-level paths in SONET (STSn) and to VT-level paths on the ONS 15310-CL with an XC-VXC-10G card. Defaults to 1E-4.
The parameter type is SF_BER, which is the threshold for declaring signal failure on a facility or path.
•1E-3
SFBER is 1E-3.
•1E-4
SFBER is 1E-4.
•1E-5
SFBER is 1E-5.
<SDBER>
Signal degrade threshold. Applies only to path protection. Applies to STS-level paths in SONET (STSn) and to VT-level paths on the ONS 15310-CL with an XC-VXC-10G card. 1E-9 is not allowed for VT-level/LO paths. Defaults to 1E-6.
The parameter type is SD_BER, which is the threshold for declaring signal degrade on a facility or path.
•1E-5
SDBER is 1E-5.
•1E-6
SDBER is 1E-6.
•1E-7
SDBER is 1E-7.
•1E-8
SDBER is 1E-8.
•1E-9
SDBER is 1E-9.
<RVRTV>
Revertive mode. The value Y indicates that the protection switching system reverts service to the original line after restoration. The value N indicates that the protection switching system does not revert service to the original line after restoration. RVRTV is applicable only for 1+1 protection switching. Null defaults to N. Only applies to path protection.
The parameter type is ON_OFF, which disables or enables an attribute.
•N
Disable an attribute.
•Y
Enable an attribute.
<RVTM>
Revertive time. RVTM is not allowed to be set while RVRTV is N. Only applies to path protection.
The parameter type is REVERTIVE_TIME (revertive time).
•0.5 to 12.0
Revertive time is 0.5 to 12.0 minutes.
<SWPDIP>
On/off switch for path protection payload defect level switching. Applicable only to STS-level paths in SONET (STSn). For the selector path on a BLSR, SWPDIP is not editable and always ON. Defaults to N.
The parameter type is ON_OFF, which disables or enables an attribute.
•N
Disable an attribute.
•Y
Enable an attribute.
<HOLDOFFTIMER>
Hold off timer for path protection dual-ring interconnect (DRI). Values must be within 0 and 10000 ms (0 to 10 seconds), with increments of 100 ms. Defaults to "existed value." HOLDOFFTIMER is an integer.
<EXPTRC>
Expected path trace content. Indicates the expected path trace message (J1) contents. EXPTRC is any 64-character ASCII string, including the terminating CR (carriage return) and LF (line feed). Applicable to STS-level paths in SONET (STSn). Applicable to VT-level paths for the DS3XM-12 and CE-100T-8 card on the ONS 15454 and the CE-100T-8 card on ONS 15310-CL. Defaults to 64 null characters. EXPTRC is a string.
<TRC>
The path trace message to be transmitted. The trace byte (J1) continuously transmits a 64-byte, fixed length ASCII string, one byte at a time. A null value defaults to the network element (NE) transmitting 62 null characters (hex 00) and CR and LF. Applicable to STS-level paths in SONET (STSn). Applicable to VT-level paths for the DS3XM-12 and CE-100T-8 card on the ONS 15454 and the CE-100T-8 card on ONS 15310-CL. For ONS 15310-CL, TRC is not provisionable on the EC/OC ports. Defaults to 64 null characters. TRC is a string.
<TRCMODE>
Path trace mode. Applicable only to STS-level paths in SONET (STSn). Defaults to the OFF mode. ONS 15310-CL EC/OC ports do not support MAN and AUTO, but can be configured as MAN-NO-AIS and AUTO-NO-AIS.
Note The ONS 15600 does not support MAN and AUTO
The parameter type is TRCMODE (trace mode).
•AUTO
Use the previously received path trace string as the expected string. Not applicable to muxponder (MXP) and transponder (TXP) cards.
•AUTO-NO-AIS
Use the previously received path trace string as the expected string and do not turn on the alarm indication signal (AIS) and remote defect indication (RDI) if TIM-P is detected.
•MAN
Use the provisioned expected string as the expected string.
•MAN-NO-AIS
Use the provisioned expected string as the expected string and do not turn on AIS and RDI if TIM-P is detected.
•OFF
Turn off path trace capability. Nothing will be reported.
<TRCFORMAT>
Path trace format. Only 64-byte is supported. Defaults to 64-byte. The parameter type is TRCFORMAT (trace format).
•64-BYTE
64 byte trace message
<TACC>
TAP number within a range of 0 to 999. Indicates whether the digroup being provisioned is to be used as a test access digroup. When TACC is 0 (zero), the TAP is deleted. TACC is an integer.
<TAPTYPE>
TAP type. Defaults to DUA The parameter type is TAPTYPE, which is the test access point type.
•DUAL
Dual FAD
•SINGLE
Single FAD
<CMDMDE>
Command mode. The parameter type is CMDMDE, which forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied. Defaults to NORM.
•FRCD
Force the system to override a state where the command would normally be denied.
•NORM
Execute the command normally. Do not override any conditions that might make the command fail.
<PST>
Primary state. Defaults to IS. The parameter type is PST, which indicates the current overall service condition of an entity.
•IS
In service
•OOS
Out of service
<SST>
Secondary state. Defaults to AINS. The parameter type is SST, which provides additional information pertaining to PST and PSTQ.
•AINS
Automatic in service
•DSBLD
Disabled
•LPBK
Loopback
•MEA
Mismatch of equipment and attributes
•MT
Maintenance mode
•OOG
Out of group
•SWDL
Software downloading
•UAS
Unassigned
•UEQ
Unequipped
11.6 ED-<MOD_RING>
(Cisco ONS 15454, ONS 15327, ONS 15600) The Edit Bidirectional Line Switched Ring (ED-<MOD_RING>) command edits the BLSR attributes.
Usage Guidelines
ONS 15327 and ONS 15600 do not support four-fiber BLSR.
The RVRTV, RVTM, SRVRTV, SRVTM, NODEID, and RINGID attributes can be edited for the four-fiber BLSR.
The RVRTV, RVTM, NODEID, and RINGID attributes can be edited for the two-fiber BLSR.
The following actions will produce errors:
•If the system fails on getting IOR, a SROF (Get IOR Failed) error message is returned.
•If the AID is invalid, an IIAC (Invalid AID) error message is returned.
•If the BLSR does not exist, a SRQN (BLSR Does Not Exist) error message is returned.
•The SROF (Facility Not Provisioned) or (Cannot Access BLSR) error message will be returned for an invalid query.
•The SRQN (BLSR Edition Failed) error message is returned for an invalid edition query.
•Sending this command to modify SRVRTV or SRVTM on a two-fiber BLSR will return an IDNV (Invalid Data For 2F-BLSR) error message.
•Sending this command to modify the nodeid with invalid data will return an IIAC (Invalid NodeId) error message.
•Sending this command to change the ringid into invalid data will return an IIAC (Invalid RingId) error message.
•Changing the BLSR nodeid with a duplicated ID will return a SROF (Cannot Set NodeId) error message.
•Changing the BLSR ringid with a duplicated ID will return a SROF (Cannot Set RingId) error message is returned.
Note•The ALL AID is invalid for this command.
•The list AID format is supported for Software Release 4.6 and later.
CategoryBLSR
SecurityProvisioning
Input FormatED-<MOD_RING>:[<TID>]:<AID>:<CTAG>:::[RINGID=<RINGID>],[NODEID=<NODEID>],
[RVRTV=<RVRTV>],[RVTM=<RVTM>],[SRVRTV=<SRVRTV>],[SRVTM=<SRVTM>][:];Input ExampleED-BLSR:PETALUMA:BLSR-43:123:::RINGID=43,NODEID=3,RVRTV=Y,RVTM=2.0,
SRVRTV=Y,SRVTM=5.0;Input Parameters
<AID>
Access identifier from the "AidUnionId1" section. Identifies the BLSR of the NE. The ALL and BLSR-ALL AIDs are not allowed for editing BLSRs.
<RINGID>
The BLSR ID of the NE up to six characters. Valid characters are A-Z and 0-9. RINGID is a string.
<NODEID>
The BLSR node ID of the NE. NODEID ranges from 0 to 31. It is an integer.
<RVRTV>
Revertive mode. The value Y indicates that the protection switching system reverts service to the original line after restoration. The value N indicates that the protection switching system does not revert service to the original line after restoration. RVRTV is applicable only for 1+1 protection switching. Null defaults to N.
The parameter type is ON_OFF, which disables or enables an attribute.
•N
Disable an attribute.
•Y
Enable an attribute.
<RVTM>
Revertive time. RVTM is not allowed to be set while RVRTV is N. The parameter type is REVERTIVE_TIME (revertive time).
•0.5 to 12.0
Revertive time is 0.5 to 12.0 minutes.
<SRVRTV>
The span revertive mode for four-fiber BLSR only. The parameter type is ON_OFF, which disables or enables an attribute.
•N
Disable an attribute.
•Y
Enable an attribute.
<SRVTM>
The span revertive time for four-fiber BLSR only. SRVTM is not allowed to be set while SRVRTV is N. The parameter type is REVERTIVE_TIME (revertive time).
•0.5 to 12.0
Revertive time is 0.5 to 12.0 minutes.
11.7 ED-<OCN_TYPE>
(Cisco ONS 15454, ONS 15327, ONS 15310-CL, ONS 15310-MA, ONS 15600) The Edit OC3, OC12, OC48, or OC192 (ED-OCN_TYPE>) command edits the attributes (for example, service parameters) and status of an OC-N facility. Allowable states for a facility are Out Of Service (OOS), Out Of Service and Automatic In Service (OOS-AINS), Out Of Service and Maintenance (OOS-MT), and In Service (IS).
Usage Guidelines
The LDCC parameter does not apply to ONS 15327.
The OPRNOMINAL parameter is supported only by optical card types that support Optical PM. The following cards support OPRNOMINAL: OC3-8, MRC-12, MRC-12-2.5G, MRC-4-2.5G, OC192-XFP, CTX-2500, CTX, OC192-4, OC48-16, OC192-4-DWDM, ASAP-4.
See Table 27-1 for supported modifiers by platform
The data communications channel (DCC) transmit side is bridged to both working and protect in a 1+1 protection scheme. On the receive side, the active one is selected for DCC. The DCC is provisioned on the working port only in a 1+1 protection scheme.
All lines in a 1+1 BLSR must have the same mode. If you change the mode of a line that is in a 1+1 BLSR, an error message will be returned.
The following apply to UNI-C DCC provisioning:
•The attributes DCC(Y/N) and mode (SONET/SDH) remain the same in the ED-OCN and RTRV-OCN commands when the DCC is used for UNI-C, in which case the port attribute UNIC is enabled (UNIC=Y).
•UNI-C DCC termination cannot be deleted by the regular DCC deprovisioning command.
•If the DCC is created under regular SONET provisioning and this port is used by UNI-C, the port is converted as a UNI-C DCC automatically.
•Deprovisioning UNI-C IF/IB IPCC will free up DCC termination automatically.
•The parameters ALSMODE, ALSCRINT, and ALSRCPW are valid only for OC3-8, OC-192, and OC48ELR cards.
•Section DCC/Line DCC (SDCC/LDCC) terminations cannot be unprovisioned if a provisionable patchcord termination endpoint is provisioned on the port.
•Synchronization status messaging (SSM) selectable (admssm) and synchronization messaging for output (syncmsgout) are not applicable to ONS 15600.
•The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. In order to obtain the current value, issue the RTRV-XX command.
•J0 Support (EXPTRC, TRC, TRCMODE, and TRCFORMAT parameters) is supported only by DWDM cards with an OC-N payload. J0 is not supported by OC3-8, OC-12, OC-48, OC-192, and other optical cards.
CategoryPorts
SecurityProvisioning
Input FormatED-<OCN_TYPE>:[<TID>]:<AID>:<CTAG>:::[DCC=<DCC>],[AREA=<AREA>],
[SYNCMSG=<SYNCMSG>],[SENDDUS=<SENDDUS>],[PJMON=<PJMON>],
[SFBER=<SFBER>],[SDBER=<SDBER>],[MODE=<MODE>],[MUX=<MUX>],
[SOAK=<SOAK>],[OSPF=<OSPF>],[LDCC=<LDCC>],[NAME=<NAME>],
[CMDMDE=<CMDMDE>],[EXPTRC=<EXPTRC>],[TRC=<TRC>],[TRCMODE=<TRCMODE>],
[TRCFORMAT=<TRCFORMAT>],[ADMSSM=<ADMSSM>],[SENDDUSFF=<SENDDUSFF>],
[AISONLPBK=<AISONLPBK>],[FREQ=<FREQ>],[LOSSB=<LOSSB>],
[FOREIGNFEND=<FOREIGNFEND>],[FOREIGNIP=<FOREIGNIP>],
[OPRNOMINAL=<OPRNOMINAL>]:[<PST>[,<SST>]];Input ExampleED-OC48:PENNGROVE:FAC-6-1:114:::DCC=Y,AREA=10.92.63.1,SYNCMSG=N,
SENDDUS=N,PJMON=48,SFBER=1E-4,SDBER=1E-6,MODE=SINGLESHELF,
MUX=E2,SOAK=10,OSPF=Y,LDCC=N,NAME="OCNPORT",CMDMDE=CMDMDE,
EXPTRC="AAA",TRC="AAA",TRCMODE=MAN,TRCFORMAT=16-BYTE,ADMSSM=PRS,
SENDDUSFF=N,AISONLPBK=AIS_ON_LPBK_ALL,FREQ=1550,LOSSB=LR-1,
FOREIGNFEND=N,FOREIGNIP="IP ADDRESS",OPRNOMINAL=Y:IS,AINS;Input Parameters
<AID>
Access identifier from the "FACILITY" section.
<DCC>
Indicates whether or not the SDCC is to be used. Identifies the SDCC connection of the port. The parameter type is ON_OFF, which disables or enables an attribute.
•N
Disable an attribute.
•Y
Enable an attribute.
<AREA>
The area ID and shows up only if the DCC is enabled. AREA is a string.
<SYNCMSG>
Synchronization status message. The parameter type is EXT_RING, which indicates whether the ring supports the extended K1/K2/K3 protocol.
•N
The ring does not support the extended K1/K2/K3 protocol.
•Y
The ring does support the extended K1/K2/K3 protocol.
<SENDDUS>
The facility will send the DUS (Do not use for Synchronization) value as the SSM for that facility. The parameter type is ON_OFF, which disables or enables an attribute.
•N
Disable an attribute.
•Y
Enable an attribute.
<PJMON>
Identifies an OC-N port PJMON. PJMON is an integer.
<SFBER>
Signal failure threshold. The parameter type is SF_BER, which is the threshold for declaring signal failure on a facility or path.
•1E-3
SFBER is 1E-3.
•1E-4
SFBER is 1E-4.
•1E-5
SFBER is 1E-5.
<SDBER>
Signal degrade threshold. The parameter type is SD_BER, which is the threshold for declaring signal degrade on a facility or path.
•1E-5
SDBER is 1E-5.
•1E-6
SDBER is 1E-6.
•1E-7
SDBER is 1E-7.
•1E-8
SDBER is 1E-8.
•1E-9
SDBER is 1E-9.
<MODE>
OC-N port mode. the parameter type is OPTICAL_MODE, which is the facility's optical mode.
•SINGLESHELF
The NE contains only one shelf and the AID representation does not consider the shelf identifier for command requests/response and autonomous reports.
•MULTISHELF
The AID representation considers the shelf identifier for command requests/response and autonomous reports. This means the NE has more than one shelf configured or the user wants to use the new AID style.
•MULTISHELFETH
The AID representation considers the shelf identifier for command requests/response and autonomous reports. This means the NE has more than one shelf configured or the user wants to use the new AID style. The shelves are connected by means of an external Ethernet switch.
<MUX>
BLSR extension byte (supported only on the OC48AS card). MUX cannot be configured if:
•The card is SONET and the media type is SDHT.
•The card has an orderwire or user data channel (UDC) connection.
•This is a protect line and the working line has an orderwire or UDC connection.
The parameter type is MUX_TYPE, which is the BLSR extension type.
•E2
E2 byte (orderwire)
•F1
F1 byte (user)
•K3
K3 byte
•Z2
Z2 byte
<SOAK>
OOS-AINS to IS transition soak time as measured in 15-minute intervals. A value of 4 equals a soak time of 1 hour. The allowable range is 0 to 192 intervals (maximum of 48 hours). Defaults to 32. SOAK is an integer.
<OSFP>
The Open Shortest Path First discovery. Defaults to Y. The parameter type is ON_OFF, which disables or enables an attribute.
•N
Disable an attribute.
•Y
Enable an attribute.
<LDCC>
The LDCC connection on the port. Defaults to N. the parameter type is EXT_RING, which indicates if the ring supports the extended K1/K2/K3 protocol.
Note LDCC is not applicable to ONS 15327.
•N
The ring does not support the extended K1/K2/K3 protocol.
•Y
The ring does support the extended K1/K2/K3 protocol.
<NAME>
NAME is a string. It defaults to NULL. Its maximum length is 32 characters.
<CMDMDE>
Command Mode. The FRCD mode of operation is applicable to delete a VCAT member cross-connect from IS-NR or OOS-AU,AINS service state. Defaults to NORM.
The parameter type is CMDMDE, which forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied.
•FRCD
Force the system to override a state where the command would normally be denied.
•NORM
Execute the command normally. Do not override any conditions that might make the command fail.
<EXPTRC>
Expected path trace content. Indicates the expected path trace message (J1) contents. EXPTRC is any 64-character ASCII string, including the terminating CR (carriage return) and LF (line feed). Applicable to STS-level paths in SONET (STSn). Applicable to VT-level paths for the DS3XM-12 card on the ONS 15454. Defaults to NULL. EXPTRC is a string.
<TRC>
The path trace message to be transmitted. The trace byte (J1) continuously transmits a 64-byte, fixed length ASCII string, one byte at a time. A null value defaults to the NE transmitting 62 null characters (hex 00) and CR and LF. Applicable to STS-level paths in SONET (STSn). Applicable to VT-level paths for the DS3XM-12 card on the ONS 15454. TRC is a string.
<TRCMODE>
Path trace mode. Applicable only to STS-level paths in SONET (STSn). Defaults to MAN. The parameter type is TRCMODE (trace mode).
•AUTO
Use the previously received path trace string as the expected string. Not applicable to MXP or TXP cards.
•AUTO-NO-AIS
Use the previously received path trace string as the expected string and do not turn on AIS and RDI if TIMP is detected.
•MAN
Use the provisioned expected string as the expected string.
•MAN-NO-AIS
Use the provisioned expected string as the expected string and do not turn on AIS and RDI if TIMP is detected.
•OFF
Turn off path trace capability. Nothing will be reported.
<TRCFORMAT>
Trace message size. The parameter type is TRCFORMAT (trace format).
•1-BYTE
1 byte trace message
•16-BYTE
16 byte trace message
•64-BYTE
64 byte trace message
<ADMSSM>
SSM selectable value. It will only appear when SSM is disabled. Defaults to STU. The parameter type is SYNC_CLOCK_REF_QUALITY_LEVEL, which is the clock source quality level for SONET.
•DUS
Do Not Use For Synchronization
•PRS
Primary Reference Source, Stratum 1 Traceable
•RES
Reserved For Network Synchronization Use
•SMC
SONET Minimum Clock Traceable
•ST2
Stratum 2 Traceable
•ST3
Stratum 3 Traceable
•ST3E
Stratum 3E Traceable
•ST4
Stratum 4 Traceable
•STU
Synchronized, Traceability Unknown
•TNC
Transit Node Clock (2nd Generation Only)
<SENDDUSFF>
The parameter type is ON_OFF, which disables or enables an attribute.
•N
Disable an attribute.
•Y
Enable an attribute.
<AISONLPBK>
The parameter type is AIS_ON_LPBK, which indicates if AIS is sent on a loopback.
•AIS_ONLPBK_FACILITY
AIS is sent on facility loopbacks.
•AIS_ON_LPBK_ALL
AIS is sent on all loopbacks.
•AIS_ON_LPBK_OFF
AIS is not sent on loopbacks.
•AIS_ON_LPBK_TERMINAL
AIS is sent on terminal loopbacks.
<FREQ>
The parameter type is OPTICAL_WLEN (optical wavelength).
•1310
Wavelength 1310
•1470
Wavelength 1470
•1490
Wavelength 1490
•1510
Wavelength 1510
•1529.55
Wavelength 1529.55
•1529.94
Wavelength 1529.94
•1530
Wavelength 1530
•1530.33
Wavelength 1530.33
•1530.73
Wavelength 1530.73
•1531.12
Wavelength 1531.12
•1531.51
Wavelength 1531.51
•1531.90
Wavelength 1531.90
•1532.29
Wavelength 1532.29
•1532.68
Wavelength 1532.68
•1533.07
Wavelength 1533.07
•1533.47
Wavelength 1533.47
•1533.86
Wavelength 1533.86
•1534.25
Wavelength 1534.25
•1534.64
Wavelength 1534.64
•1535.04
Wavelength 1535.04
•1535.43
Wavelength 1535.43
•1535.82
Wavelength 1535.82
•1536.22
Wavelength 1536.22
•1536.61
Wavelength 1536.61
•1537
Wavelength 1537
•1537.40
Wavelength 1537.40
•1537.79
Wavelength 1537.79
•1538.19
Wavelength 1538.19
•1538.58
Wavelength 1538.58
•1538.98
Wavelength 1538.98
•1539.37
Wavelength 1539.37
•1539.77
Wavelength 1539.77
•1540.16
Wavelength 1540.16
•1540.56
Wavelength 1540.56
•1540.95
Wavelength 1540.95
•1541.35
Wavelength 1541.35
•1541.75
Wavelength 1541.75
•1542.14
Wavelength 1542.14
•1542.35
Wavelength 1542.35
•1542.54
Wavelength 1542.54
•1542.94
Wavelength 1542.94
•1543.33
Wavelength 1543.33
•1543.73
Wavelength 1543.73
•1544.13
Wavelength 1544.13
•1544.53
Wavelength 1544.53
•1544.92
Wavelength 1544.92
•1545.32
Wavelength 1545.32
•1545.72
Wavelength 1545.72
•1546.12
Wavelength 1546.12
•1546.52
Wavelength 1546.52
•1546.92
Wavelength 1546.92
•1547.32
Wavelength 1547.32
•1547.72
Wavelength 1547.72
•1548.12
Wavelength 1548.12
•1548.51
Wavelength 1548.51
•1548.92
Wavelength 1548.92
•1549.32
Wavelength 1549.32
•1549.71
Wavelength 1549.71
•1550
Wavelength 1500
•1550.12
Wavelength 1550.12
•1550.52
Wavelength 1550.52
•1550.92
Wavelength 1550.92
•1551.32
Wavelength 1551.32
•1551.72
Wavelength 1551.72
•1552.12
Wavelength 1552.12
•1552.52
Wavelength 1552.52
•1552.93
Wavelength 1552.93
•1553.33
Wavelength 1553.33
•1553.73
Wavelength 1553.73
•1554.13
Wavelength 1554.13
•1554.13
Wavelength 1554.13
•1554.94
Wavelength 1554.94
•1555.34
Wavelength 1555.34
•1555.75
Wavelength 1555.75
•1556.15
Wavelength 1556.15
•1556.55
Wavelength 1556.55
•1556.96
Wavelength 1556.96
•1557.36
Wavelength 1557.36
•1557.77
Wavelength 1557.77
•1558.17
Wavelength 1558.17
•1558.58
Wavelength 1558.58
•1558.98
Wavelength 1558.98
•1559.39
Wavelength 1559.39
•1559.79
Wavelength 1559.79
•1560.20
Wavelength 1560.20
•1560.61
Wavelength 1560.61
•1561.01
Wavelength 1561.01
•1561.42
Wavelength 1561.42
•1561.83
Wavelength 1561.83
•1570
Wavelength 1570
•1570.83
Wavelength 1570.83
•1571.24
Wavelength 1571.24
•1571.65
Wavelength 1571.65
•1572.06
Wavelength 1572.06
•1572.48
Wavelength 1572.48
•1572.89
Wavelength 1572.89
•1573.30
Wavelength 1573.30
•1573.71
Wavelength 1573.71
•1574.13
Wavelength 1574.13
•1574.54
Wavelength 1574.54
•1574.95
Wavelength 1574.95
•1575.37
Wavelength 1575.37
•1575.78
Wavelength 1575.78
•1576.20
Wavelength 1576.20
•1576.61
Wavelength 1576.61
•1577.03
Wavelength 1577.03
•1577.44
Wavelength 1577.44
•1577.86
Wavelength 1577.86
•1578.27
Wavelength 1578.27
•1578.69
Wavelength 1578.69
•1579.10
Wavelength 1579.10
•1579.52
Wavelength 1579.52
•1579.93
Wavelength 1579.93
•1580.35
Wavelength 1580.35
•1580.77
Wavelength 1580.77
•1581.18
Wavelength 1581.18
•1581.60
Wavelength 1581.60
•1582.02
Wavelength 1582.02
•1582.44
Wavelength 1582.44
•1582.85
Wavelength 1582.85
•1583.27
Wavelength 1583.27
•1583.69
Wavelength 1583.69
•1584.11
Wavelength 1584.11
•1584.53
Wavelength 1584.53
•1584.95
Wavelength 1584.95
•1585.36
Wavelength 1585.36
•1585.78
Wavelength 1585.78
•1586.20
Wavelength 1586.20
•1586.62
Wavelength 1586.62
•1587.04
Wavelength 1587.04
•1587.46
Wavelength 1587.46
•1587.88
Wavelength 1587.88
•1588.30
Wavelength 1588.30
•1588.73
Wavelength 1588.73
•1589.15
Wavelength 1589.15
•1589.57
Wavelength 1589.57
•1589.99
Wavelength 1589.99
•1590
Wavelength 1590
•1590.41
Wavelength 1590.41
•1590.83
Wavelength 1590.83
•1591.26
Wavelength 1591.26
•1591.68
Wavelength 1591.68
•1592.10
Wavelength 1592.10
•1592.52
Wavelength 1592.52
•1592.95
Wavelength 1592.95
•1593.37
Wavelength 1593.37
•1593.79
Wavelength 1593.79
•1594.22
Wavelength 1594.22
•1594.64
Wavelength 1594.64
•1595.06
Wavelength 1595.06
•1595.49
Wavelength 1595.49
•1596.34
Wavelength 1596.34
•1596.76
Wavelength 1596.76
•1597.19
Wavelength 1597.19
•1597.62
Wavelength 1597.62
•1598.04
Wavelength 1598.04
•1598.47
Wavelength 1598.47
•1598.89
Wavelength 1598.89
•1599.32
Wavelength 1599.32
•1599.75
Wavelength 1599.75
•1600.06
Wavelength 1600.06
•1601.03
Wavelength 1601.03
•1601.46
Wavelength 1601.46
•1601.88
Wavelength 1601.88
•1602.31
Wavelength 1602.31
•1602.74
Wavelength 1602.74
•1603.17
Wavelength 1603.17
•1603.60
Wavelength 1603.60
•1604.03
Wavelength 1604.03
•1610
Wavelength 1610
•USE-TWL1
Use Tunable Wavelength 1
<LOSSB>
The parameter type is REACH (reach value)
•AUTOPROV
Autoprovisioning
•CX
Reach CX
•DX
Reach DX
•HX
Reach HX
•I1
Reach I1
•IR-1
Reach IR-1
•IR-2
Reach IR-2
•L1
Reach L1
•L2
Reach L2
•L3
Reach L3
•LR-1
Reach LR-1
•LR-2
Reach LR-2
•LR-3
Reach LR-3
•LX
Reach LX
•S1
Reach S1
•S2
Reach S2
•SR
Reach SR
•SR-1
Reach SR-1
•SX
Reach SX
•T
Reach T
•VX
Reach VX
•ZX
Reach ZX
<FOREIGNFEND>
Indicates whether the far-end NE on the DCC is a foreign NE. The parameter type is ON_OFF, which disables or enables an attribute.
•N
Disable an attribute.
•Y
Enable an attribute.
<FOREIGNIP>
The IP address of the far-end NE on the DCC. Used only if FOREIGNFEND is Y. FOREIGHNIP is a string.
<OPRNOMINAL>
Set to Y reads the current raw optical receive power and sets the raw OPR value as nomimal optical receive power. After executing this command, the OPRN is set to approximately 100.
Note The OPRNOMINAL value of N is not supported.
The parameter type is ON_OFF, which disables or enables an attribute.
•N
Disable an attribute. Not supported for OPRNOMINAL.
•Y
Enable an attribute.
<PST>
Primary state. Defaults to IS. The parameter type is PST, which indicates the current overall service condition of an entity.
•IS
In service
•OOS
Out of service
<SST>
Secondary state. Defaults to AINS. The parameter type is SST, which provides additional information pertaining to PST and PSTQ.
•AINS
Automatic in service
•DSBLD
Disabled
•LPBK
Loopback
•MEA
Mismatch of equipment and attributes
•MT
Maintenance mode
•OOG
Out of group
•SWDL
Software downloading
•UAS
Unassigned
•UEQ
Unequipped
11.8 ED-ALS
(Cisco ONS 15454, ONS 15310-CL, ONS 15310-MA) The Edit Automatic Laser Shutdown (ED-ALS) command is used to modify the ALS attributes of an OC-N facility and all the facilities that support the ALS feature. For MXP_2.5G_10E, TXP_MR_10E, MXP_2.5G_10G, TXP_MR_10G, TXP_MR_2.5G, and TXPP_MR_2.5G cards, this command is used to modify the ALS parameter of the OC48 and OC192 ports.
Usage Guidelines
None
CategoryPorts
SecurityProvisioning
Input FormatED-ALS:[<TID>]:<SRC>:<CTAG>:::[ALSMODE=<ALSMODE>],[ALSRCINT=<ALSRCINT>],
[ALSRCPW=<ALSRCPW>][:];Input ExampleED-ALS:CISCO:FAC-1-1:100:::ALSMODE=AUTO,ALSRCINT=130,ALSRCPW=35.1;
Input Parameters
<SRC>
Access identifier from the "AidUnionId" section.
<ALSMODE>
ALS is enabled or disabled. The parameter type is ALS_MODE, which is the working mode for automatic laser shutdown. Defaults to DISABLED.
•AUTO
Automatic
•DISABLED
Disabled
•MAN
Manual
•MAN-RESTART
Manual restart for test
<ALSRCINT>
ALS recovery interval. The range is 60 to 300 seconds. ALSRCINT is an integer. Defaults to 100.
<ALSRCPW>
ALS recovery pulse width. The range is 80 to 100 seconds. Defaults to 80. ALSRCWP is a float.
11.9 ED-APC
(Cisco ONS 15454) The Edit Amplification Power Control (ED-APC) command is used to modify the APC application attributes. The default value for an optional parameter is the NE default value. The value might not be the current value for the parameter. Use a RTRV-xx command to retrieve the current value.
Usage Guidelines
None
CategoryDWDM
SecurityProvisioning
Input FormatED-APC:[<TID>]::<CTAG>[:::APCENABLE=<APCENABLE>];
Input ExampleED-APC:PENNGROVE::CTAG:::APCENABLE=N;
Input Parameters
<APCENABLE>
Enable or disable the APC application. Default is N. The parameter type is ON_OFF, which disables or enables an attribute.
•N
Disable an attribute.
•Y
Enable an attribute.
11.10 ED-BITS
(Cisco ONS 15454, ONS 15327, ONS 15310-CL, ONS 15310-MA, ONS 15600) The Edit Building Integrated Timing Supply (ED-BITS) command edits the building integrated timing supply (BITS) reference attributes.
Usage Guidelines
The SYNC-BITS1 and SYNC-BITS2 AIDs can be used to set the BITS-OUT port state. For a BITS facility, 64 k and 6 MHz are only applicable to ON. SSM selectable (ADMSSM) is not applicable to ONS 15600.
The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. In order to obtain the current value, issue the RTRV-XX command.
CategorySynchronization
SecurityProvisioning
Input FormatED-BITS:[<TID>]:<AID>:<CTAG>:::[LINECDE=<LINECDE>],[FMT=<FMT>],[LBO=<LBO>],
[SYNCMSG=<SYNCMSG>],[AISTHRSHLD=<AISTHRSHLD>],[SABIT=<SABIT>],
[BITSFAC=<BITSFAC>],[ADMSSM=<ADMSSM>][:<PST>];Input ExampleED-BITS:SONOMA:BITS-2:779:::LINECDE=AMI,FMT=ESF,LBO=0-133,SYNCMSG=N,
AISTHRSHLD=PRS,SABIT=BYTE-5,IMPEDANCE=120-OHM,BITSFAC=T1,ADMSSM=PRS:IS;Input Parameters
<AID>
Access identifier from the "BITS" section.
<LINECDE>
The parameter type is LINE_CODE (line code).
•AMI
Line code value is AMI.
•B8ZS
Line code value is B8ZS (binary 8-zero substitution)
<FMT>
Digital signal frame format. The parameter type is FRAME_FORMAT, which is the frame format for a T1 port.
•D4
Frame format is D4.
•ESF
Frame format is Extended Superframe (ESF).
•UNFRAMED
Frame format is unframed.
<LBO>
Line build-out settings. BITS line build-out. Default value is 0 to 133. LBO is an integer. The parameter type is BITS_LineBuildOut (BITS line build-out).
•0-133
BITS line build-out range is 0-133.
•134-266
BITS line build-out range is 134-266.
•267-399
BITS line build-out range is 267-399.
•400-533
BITS line build-out range is 400-533.
•534-655
BITS line build-out range is 534-655.
<SYNCMSG>
Indicates if the BITS facility supports synchronization status message. Default is ON (Y). The parameter type is EXT_RING, which indicates whether the ring supports the extended K1/K2/K3 protocol.
•N
The ring does not support the extended K1/K2/K3 protocol.
•Y
The ring does support the extended K1/K2/K3 protocol.
<AISTHRSHLD>
Alarm indication signal threshold. The parameter type is SYNC_CLOCK_REF_QUALITY_LEVEL, which is the clock source quality level for SONET.
•DUS
Do Not Use For Synchronization
•PRS
Primary Reference Source, Stratum 1 Traceable
•RES
Reserved For Network Synchronization Use
•SMC
SONET Minimum Clock Traceable
•ST2
Stratum 2 Traceable
•ST3
Stratum 3 Traceable
•ST3E
Stratum 3E Traceable
•ST4
Stratum 4 Traceable
•STU
Synchronized, Traceability Unknown
•TNC
Transit Node Clock (2nd Generation Only)
<SABIT>
When the frame format selection is E1, SABIT is the bit used to receive and transmit the SSM. The parameter type is SABITS (SA BITS).
•BYTE-4
SABIT is BYTE-4.
•BYTE-5
SABIT is BYTE-5.
•BYTE-6
SABIT is BYTE-6.
•BYTE-7
SABIT is BYTE-7.
•BYTE-8
SABIT is BYTE-8.
<IMPEDANCE>
When the frame format selection is E1, IMPEDANCE is the terminal impedance of the BITS-IN port. The parameter type is IMPEDANCE, which is the terminal impedance of the BITS-IN port.
•120-OHM
Impedance of 120 ohm
•75-OHM
Impedance of 75 ohm
<BITSFAC>
BITS facility settings. BITS-2 always inherits the value of BITS-1. The parameter type is BITS_FAC (the BITS facility rate). 64 k and 6 MHz are only applicable to the ONS 15454.
•2 M
2 MHz rate
•64 K
64 K rate
•6 M
6 MHz rate
•E1
E1 rate
•T1
T1 rate
<ADMSSM>
SSM selectable. Only applicable to BITS-IN when SSM is disabled.
Note Not applicable for ONS 15600.
The parameter type is SYNC_CLOCK_REF_QUALITY_LEVEL, which is the clock source quality level for SONET.
•DUS
Do Not Use For Synchronization
•PRS
Primary Reference Source, Stratum 1 Traceable
•RES
Reserved For Network Synchronization Use
•SMC
SONET Minimum Clock Traceable
•ST2
Stratum 2 Traceable
•ST3
Stratum 3 Traceable
•ST3E
Stratum 3E Traceable
•ST4
Stratum 4 Traceable
•STU
Synchronized, Traceability Unknown
•TNC
Transit Node Clock (2nd Generation Only)
<PST>
The primary state. The parameter type is PST, which indicates the current overall service condition of an entity.
•IS
In service
•OOS
Out of service
11.11 ED-BULKROLL-<OCN_TYPE>
(Cisco ONS 15454, ONS 15327, ONS 15310-CL, ONS 15310-MA, ONS 15600) The Edit Bulkroll for OC12, OC192, OC3, or OC48 (ED-BULROLL-<OCN_TYPE>) command edits information about the rolling of traffic from one endpoint to another without interrupting service. This command uses the FORCE option to force a valid signal. The only parameters that can be edited are RMODE and FORCE. The time slots cannot be edited. Use ED-ROLL-<MOD_PATH> for single path level rolling.
Usage Guidelines
See Table 27-1 for supported modifiers by platform.
CategoryBridge and Roll
SecurityProvisioning
Input FormatED-BULKROLL-<OCN_TYPE>:[<TID>]:<FROM>:<CTAG>:::
[RFROMSTART=<RFROMSTART>],[RFROMEND=<RFROMEND>],[CMDMDE=<CMDMDE>];Input ExampleED-BULKROLL-OC48:CISCO:FAC-1-1:1:::RFROMSTART=STS-1-1-1,
RFROMEND=STS-1-1-11,CMDMDE=FRCD;Input Parameters
<FROM>
One of the endpoints. Access identifier from the "FACILITY" section for line level rolling and bulk rolling.
<RFROMSTART>
The starting time slot in the source roll port. For bulk rolling only. The AID is from the "CrossConnectId1" section (except VCM and FACILITY). Defaults to STS-<FROMSLOT>-<FROMPORT>-1, where <FROMSLOT> and <FROMPORT> are the slot and port of the <FROM> AID.
<RFROMEND>
The ending time slot in the source roll port. For bulk rolling only. The AID is from the "CrossConnectId1" section (except VCM and FACILITY). Defaults to STS-<FROMSLOT>-<FROMPORT>-N, where <FROMSLOT> and <FROMPORT> are the slot and port of the <FROM> AID and N is the value of OCn. (for example, OC48, n=48).
<CMDMDE>
Command execution mode. Defaults to NORM. The parameter type is CMDMDE, which forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied.
•FRCD
Force the system to override a state where the command would normally be denied.
•NORM
Execute the command normally. Do not override any conditions that might make the command fail.
11.12 ED-CMD-SECU
(Cisco ONS 15454, ONS 15327, ONS 15310-CL, ONS 15310-MA, ONS 15600) The Edit Command Security (ED-CMD-SECU) command edits the command security level of a particular command.
Usage Guidelines
None
CategorySecurity
SecuritySuperuser
Input FormatED-CMD-SECU:[<TID>]:<AID>:<CTAG>::<CAP>;
Input ExampleED-CMD-SECU::INIT-REG:1::SU;
Input Parameters
11.13 ED-CRS-<PATH>
(Cisco ONS 15454, ONS 15327, ONS 15310-CL, ONS 15310-MA, ONS 15600) The Edit Cross-Connect for STS1, STS12C, STS18C, STS192C, STS24C, STS36C, STS3C, STS48C, STS6C, STS9C, VT1, or VT2 (ED-CRS-<PATH>) command edits a cross-connection.
Usage Guidelines
See Table 27-1 for supported modifiers by platform.
Note•ADD and REMOVE cannot be used together. The example provided is for informational purposes only. ADD and REMOVE are mutually exclusive.
•Add/Remove drops is possible only on ONEWAY, UPSR_DROP, UPSR_DC, and UPSR_EN type cross-connects (one-way only).
•Traditional cross-connections cannot be upgraded to DRI cross-connections using the ED_CRS command.
•CKTID is a string of ASCII characters. The maximum length of CKTID is 48. If the CKTID is EMPTY or NULL, this field will not appear.
•You cannot add a drop onto unidrectional connections on BLSR DRI primary or secondary nodes.
CategoryCross Connections
SecurityProvisioning
Input FormatED-CRS-<PATH>:[<TID>]:<SRC>,<DST>:<CTAG>::[<CCT>]:[ADD=<ADD>],
[REMOVE=<REMOVE>],[CKTID=<CKTID>],[CMDMDE=<CMDMDE>]:[<PST>[,<SST>]];Input ExampleED-CRS-STS3C::STS-1-1-1,STS-2-1-1:1:::ADD=STS-13-1-1,REMOVE=STS-2-1-1,CKTID=CKTID
CMDMDE=FRCD:IS,AINS;Input Parameters
<SRC>
Source AID from the "CrossConnectId1" section.
<DST>
Destination AID from the "CrossConnectId1" section.
<CCT>
Cross-connection. The parameter type is CCT which indicates the type of cross-connection to be created.
•1WAY
A unidirectional connection from a source tributary to a destination tributary
•1WAYDC
path protection multicast drop with (1-way) continue
•1WAYEN
path protection multicast end node (1-way continue)
•1WAYMON
A bidirectional connection between the two tributaries
Note In ONS 15454 Software Release 3.0 and later and ONS 15327 Software R3.3 and later, 1WAYMON is not supported with TL1. However, it is still supported from Cisco Transport Controller (CTC). Using CTC, you can create 1WAYMON cross-connects that can be retrieved with TL1.
•1WAYPCA
A unidirectional connection from a source tributary to a destination tributary on the protection path/fiber
•2WAY
A bidirectional connection between the two tributaries
•2WAYDC
A bidirectional drop and continue connection applicable only to path protection traditional and integrated DRIs
•2WAYPCA
A bidirectional connection between the two tributaries on the extra protection path/fiber
•DIAG
Diagnostics cross-connect. Supports BERT (BLSR PCA diagnostics cross-connect).
<ADD>
AID from the "AidUnionId" section.
<REMOVE>
AID from the "AidUnionId" section.
<CKTID>
String
<CMDMDE>
Command Mode. The FRCD mode of operation is applicable only if the PST=OOS and SST=DSBLD.
The parameter type is CMDMDE, which forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied.
•FRCD
Force the system to override a state where the command would normally be denied.
•NORM
Execute the command normally. Do not override any conditions that might make the command fail.
<PST>
Primary state. The parameter type is PST, which indicates the current overall service condition of an entity.
•IS
In service
•OOS
Out of service
<SST>
Secondary state. The parameter type is SST, which provides additional information pertaining to PST and PSTQ.
•AINS
Automatic in-service
•DSBLD
Disabled
•LPBK
Loopback
•MEA
Mismatch of equipment and attributes
•MT
Maintenance mode
•OOG
Out of group
•SWDL
Software downloading
•UAS
Unassigned
•UEQ
Unequipped
11.14 ED-DAT
(Cisco ONS 15454, ONS 15327, ONS 15310-CL, ONS 15310-MA, ONS 15600) The Edit Date and Time (ED-DAT) command edits the date and the time.
Usage Guidelines
None
CategorySystem
SecurityProvisioning
Input FormatED-DAT:[<TID>]::<CTAG>::[<DATE>],[<TIME>];
Input ExampleED-DAT:CISCO::1234::99-12-21,14-35-15;
Input Parameters
11.15 ED-DS1
(Cisco ONS 15454) The Edit DS1 (ED-DS1) command edits the test access attribute for DS1 access on a DS3XM card.
Usage Guidelines
•This command is not allowed if the card is a protect card.
•Both the MODE and FMT fields of this command apply to the DS3XM-12 card only.
•For the DS3XM-12 card, the DS1 frame format NE default is AUTO_PROV_FMT for the first 30 seconds to determine the real format. After 30 seconds, the DS1 frame format will be detected as FRAMED. If the frame format is not detected, it will be in the UNFRAMED format.
•For preprovisioning the DS3XM-12 card, the DS1 frame format defaults to UNFRAMED.
•For the DS3XM-12 card, the DS1 configurable attributes (PM, TH, alarm, etc.) only apply on the ported ports (Ports 1 to 12) and the VT-mapped (odd) portless ports in xxx-xxx-DS1 commands. If you provision or retrieve DS1 attributes on the DS3-mapped (even) portless port in xxx-xxx-DS1 commands, an error message will be returned.
•The test set physical connection that is set up through the ED-T3/DS1/STS1/VT1 command of the DS3XM-12 card is only allowed on the physical front ports (PORTED ports, Ports 1 to 12), which are the monitoring ports, as follows:
–The monitoring test access ports follow the common rules for the other cards. For example, when issuing the ED-T3 command on Port 2 (FAC-6-2) with a TACC number (8), the next port, Port 3 (FAC-6-3) is used as the monitoring point also. The RTRV-T3 command on both Port 2 and Port 3 return the same TACC number (8) being used to monitor the cross-connection end (A-B). The last port (Port 12) is not allowed to set up a physical connection with the test set because there is no next available port to be the monitoring port.
–The TACC disconnection (DISC-TACC) and the test access mode change command (CHG-TACC) follow the same requirement as in the previous step, but it is applied on the ported ports of the DS3XM-12 card.
–The test access connection set-up command (CONN-TACC) has monitored points, which can be portless ports. This command is applied on both ported and portless ports of the DS3XM-12 card.
•If the entity has a TACC connection, the entity is not allowed to have ported or portless STS/VT cross-connection (or circuit) provisioning on the DS3XM-12 card.
CategoryPorts
SecurityProvisioning
Input FormatED-DS1:[<TID>]:<AID>:<CTAG>:::[TACC=<TACC>],[TAPTYPE=<TAPTYPE>],
[AISONLPBK=<AISONLPBK>],[MODE=<MODE>],[FMT=<FMT>];Input ExampleED-DS1:PETALUMA:DS1-2-1-12:123:::TACC=8,TAPTYPE=DUAL,AISONLPBK=OFF,
MODE=FDL,FMT=ESF;Input Parameters
<AID>
Access identifier from the "DS1" section.
<TACC>
TAP number within a range of 0 to 999. Indicates whether the digroup being provisioned is to be used as a test access digroup. When TACC is 0 (zero), the TAP is deleted. TACC is an integer.
<TAPTYPE>
TAP type. The parameter type is TAPTYPE (test access point type).
•DUAL
Dual FAD
•SINGLE
Single FAD
<AISONLPBK>
The parameter type is AIS_ON_LPBK, which indicates whether AIS is sent on a loopback.
•AIS_ONLPBK_FACILITY
AIS is sent on facility loopbacks.
•AIS_ON_LPBK_ALL
AIS is sent on all loopbacks.
•AIS_ON_LPBK_OFF
AIS is not sent on loopbacks.
•AIS_ON_LPBK_TERMINAL
AIS is sent on terminal loopbacks.
<MODE>
Mode with which the command is to be implemented. DS1 path mode of the DS3XM-12 card. Defaults to FDL. The parameter type is DS1MODE, which is the DS1 path mode of the DS3XM-12 card.
•ATT
The DS1 path of the DS3XM-12 card is in AT&T 54016 mode.
•FDL
The DS1 path of the DS3XM-12 card is in FDL T1-403 mode.
<FMT>
Digital signal format. The DS1 path frame format of the DS3XM-12 card. Defaults to UNFRAMED. The parameter type is FRAME_FORMAT, which is the frame format for a T1 port.
•D4
Frame format is D4.
•ESF
Frame format is ESF.
•UNFRAMED
Frame format is unframed.
11.16 ED-EC1
(Cisco ONS 15454, ONS 15310-CL, ONS 15310-MA) The Edit Electrical Carrier (ED-EC1) command edits the attributes of an EC1 card.
Usage Guidelines
This command is not allowed if the card is a protecting card.
CategoryPorts
SecurityProvisioning
Input FormatED-EC1:[<TID>]:<AID>:<CTAG>:::[PJMON=<PJMON>],[LBO=<LBO>],[SOAK=<SOAK>],
[SFBER=<SFBER>],[SDBER=<SDBER>],[NAME=<NAME>],[EXPTRC=<EXPTRC>],
[TRC=<TRC>],[TRCMODE=<TRCMODE>],[<TRCFORMAT>],[AISONLPBK=<AISONLPBK>],
[CMDMDE=<CMDMDE>]:[<PST>[,<SST>]];Input ExampleED-EC1:CISCO:FAC-1-1:123:::PJMON=0,LBO=0-225,SOAK=10,SFBER=1E-4,SDBER=1E-6,
NAME="EC1 PORT",EXPTRC="AAA",TRC="AAA",TRCMODE=MAN,TRCFORMAT="16-BYTE,
AISONLPBK=AIS_ON_LPBK_ALL,CMDMDE=CMDMDE:IS,AINS;Input Parameters
<AID>
Access identifier from the "FACILITY" section.
<PJMON>
A SONET pointer number (0 or 1) of an EC1 port. PJMON is an integer. It defaults to 0.
<LBO>
Line build-out settings. LBO is an integer. It defaults to 0-225. The parameter type is E_LBO (electrical signal line build-out).
•0-225
Electrical signal line build-out range is 0-225.
•226-450
Electrical signal line build-out range is 226-450.
<SOAK>
IS-AINS to IS transition soak time as measured in 15-minute intervals. A value of 4 equals a soak time of 1 hour. The allowable range is 0 to 192 intervals (maximum of 48 hours). SOAK is an integer. Defaults to 32.
<SFBER>
Signal failure threshold. Defaults to 1E-4. The parameter type is SF_BER, which is the threshold for declaring signal failure on a facility or path.
•1E-3
SFBER is 1E-3.
•1E-4
SFBER is 1E-4.
•1E-5
SFBER is 1E-5.
<SDBER>
Signal degrade threshold. Defaults to 1E-7. The parameter type is SD_BER, which is the threshold for declaring signal degrade on a facility or path.
•1E-5
SDBER is 1E-5.
•1E-6
SDBER is 1E-6.
•1E-7
SDBER is 1E-7.
•1E-8
SDBER is 1E-8.
•1E-9
SDBER is 1E-9.
<NAME>
NAME is a string. Default value is NULL. Maximum length is 32 characters.
<EXPTRC>
String
<TRC>
String
<TRCMODE>
The parameter type is TRCMODE (trace mode).
•AUTO
Use the previously received path trace string as the expected string. Not applicable to MXP/TXP cards.
•AUTO-NO-AIS
Use the previously received path trace string as the expected string and do not turn on AIS and RDI if TIM-P is detected.
•MAN
Use the provisioned expected string as the expected string.
•MAN-NO-AIS
Use the provisioned expected string as the expected string and do not turn on AIS and RDI if TIM-P is detected.
•OFF
Turn off path trace capability. Nothing will be reported.
<TRCFORMAT>
Trace message size. The parameter type is TRCFORMAT (trace format).
•1-BYTE
1 byte trace message.
•16-BYTE
16 byte trace message.
•64-BYTE
64 byte trace message.
•Y
Enable an attribute.
<AISONLPBK>
Defaults to AIS_ONLPBK_FACILITY. The parameter type is AIS_ON_LPBK, which indicates whether AIS is sent on a loopback.
•AIS_ONLPBK_FACILITY
AIS is sent on facility loopbacks.
•AIS_ON_LPBK_ALL
AIS is sent on all loopbacks.
•AIS_ON_LPBK_OFF
AIS is not sent on loopbacks.
•AIS_ON_LPBK_TERMINAL
AIS is sent on terminal loopbacks.
<CMDMDE>
Command Mode. Defaults to NORM. The parameter type is CMDMDE, which forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied.
•FRCD
Force the system to override a state where the command would normally be denied.
•NORM
Execute the command normally. Do not override any conditions that might make the command fail.
<PST>
Primary state. Defaults to IS. The parameter type is PST, which indicates the current overall service condition of an entity.
•IS
In service
•OOS
Out of service
<SST>
Secondary state. Defaults to AINS. The parameter type is SST, which provides additional information pertaining to PST and PSTQ.
•AINS
Automatic in-service
•DSBLD
Disabled
•LPBK
Loopback
•MEA
Mismatch of equipment and attributes
•MT
Maintenance mode
•OOG
Out of group
•SWDL
Software downloading
•UAS
Unassigned
•UEQ
Unequipped
11.17 ED-EQPT
Note The ONS 15600 only supports the TID, AID, CTAG, PST, and SST parameters.
(Cisco ONS 15454, ONS 15327, ONS 15310-CL, ONS 15310-MA, ONS 15600) The Edit Equipment (ED-EQPT) command edits the attributes for a given equipment slot in the NE. If the card is in an equipment slot, this command is allowed only on the working AID.
The ED-EQPT command also modifies a shelf role from NC to SC on an NE configured in multi-shelf mode.
Usage Guidelines
The PROTID parameter indicates the unique identifier of the protection group (the protect card). "NULL" is a special value of the PROTID parameter and indicates the absence of a protection group. For the 1:1 protection type, RVRTV and RVTM parameters can be changed. For the 1:1 protection type, if the PROTID parameter is entered as "NULL", the protection group is deleted, as shown in the following command:
ED-EQPT:[<TID>]:SLOT-2:<CTAG>:::PROTID=NULL;
For the 1:N protection type, if the PROTID is "NULL," the AIDs in the list are removed from the protection group. If all the working cards are in the AID list, the protection group is deleted.
For example, if Slot 1, Slot 2, and Slot 4 were the only working cards in the protection group, the following command would remove Slot 4 from the protection group:
ED-EQPT:[<TID>]:SLOT-4:<CTAG>:::PROTID=NULL;
The protection group still has Slot 1 and Slot 2 as working cards.
The following command will remove all the other working cards in the above example and consequently, delete the protection group itself:
ED-EQPT:[<TID>]:SLOT-2&SLOT-1:<CTAG>:::PROTID=NULL;
The ED-EQPT command can be successfully executed on an already provisioned card to add or remove a working card from a protection group. This command is not valid on a protect card. Only cards can be added to or removed from a protection group. Protection type is immutable and is determined at the time of creation of a protection group (while adding the first working card). After it is provisioned, the equipment type cannot be edited either.
Examples of adding an existing card to a protection group using the ED-EQPT command:
1:1 protection group:
ED-EQPT::SLOT-2:12:::PROTID=SLOT-1,RVRTV=Y,RVTM=9.0;
1:N protection group:
ED-EQPT::SLOT-2:12:::PROTID=SLOT-3,PRTYPE=1-N,RVTM=6.5;
Error conditions for editing a 1:1 or 1:N protection group might be:
•Editing the PRTYPE or PROTID (non-NULL value) parameters.
•Editing RVRTV or RVTM when no protection group exists.
•Editing RVRTV for 1:N protection.
•Failed to remove, currently switched to protect.
•The CARDMODE provisioning is allowed on the DS3XM-12 and ML-Series cards, as follows:
–The DS3XM's provisioning is based on the XCON type and DS3XM-12's location. For example, the DS3XM-12 card in the lower speed I/O slot with the XCVT/XC10G card only allows the DS3XM-12-STS12 CARDMODE. Other cases allow the CARDMODE to be DS3XM-12-STS-48.
–There is no card reboot if the CARDMODE is changed on the DS3XM-12 card.
–The DS3XM-12 card can be upgraded or downgraded by changing the CARDMODE with the ED-EQPT command.
•If the command mode (CMDMDE) is set to forced (FRCD) during the creation of a 1:1 or 1:N protection group, all cards must be physically plugged in and in the service state (IS). If the cards are not physically plugged in, then the command is denied with an appropriate error message. When the command mode is set to normal (NORM) (which is the default) the cards do not have to be physically plugged in and in the service state.
•If the command mode is set to FRCD during the removal of a card in a 1:1 or 1:N protection group, there must be no cross-connects (for example, services) present on the card. If there are cross-connects present on the card, the command is denied with an appropriate error message. If the command mode is set to normal (NORM) (which is the default), it does not require that cross-connects be deleted on the card.
Note For the FC_MR-4 card, the card mode cannot be changed to FCMR-LINERATE when the payload on any port is 1GFICON or 2GFICON. These payloads are allowed only in distance extension card mode.
Note On the Cisco ONS 15310-MA, only 1:1 protection groups are supported. Protection groups are automatically created when the protect card is provisioned. The protection group is automatically deleted when the protect card is deleted. The protection group cannot be deleted by entering NULL for the PROTID parameter, doing so will return the Provisioning Rules Failed (SROF) error.
CategoryEquipment
SecurityProvisioning
Input FormatED-EQPT:[<TID>]:<AID>:<CTAG>:::[PROTID=<PROTID>],[PRTYPE=<PRTYPE>],
[RVRTV=<RVRTV>],[RVTM=<RVTM>],[CMDMDE=<CMDMDE>],
[CARDMODE=<CARDMODE>],[PEERID=<PEERID>],[REGENNAME=<REGENNAME>],
[PWL=<PWL>],[RETIME=<RETIME>],[SHELFROLE=<SHELFROLE>],
[NEWSHELFID=<NEWSHELFID>]:[<PST>[,<SST>]];Input ExampleED-EQPT:CISCO:SLOT-2:123:::PROTID=SLOT-1,PRTYPE=1-1,RVRTV=Y,RVTM=9.0,
CMDMDE=FRCD,CARDMODE=DS3XM12-STS48,PEERID=SLOT-2,
REGENNAME="THIS GROUP",PWL=1530.33,RETIME=Y,SHELFROLE=SC,
NEWSHELFID=2:OOS,MT;Input Parameters
<AID>
Access identifier from the "EQPT" section.
<PROTID>
Protect card slot number of the protection group from the "PRSLOT" section.
<PRTYPE>
Protection group type. The parameter type is PROTECTION_GROUP.
•1-1
1:1 protection group
•1-N
1:N protection group
<RVRTV>
Revertive mode. The value Y indicates that the protection switching system reverts service to the original line after restoration. The value N indicates that the protection switching system does not revert service to the original line after restoration. RVRTV is applicable only for 1+1 protection switching. Null defaults to N. The parameter type is ON_OFF, which disables or enables an attribute.
•N
Disable an attribute.
•Y
Enable an attribute.
<RVTM>
Revertive time. The parameter type is REVERTIVE_TIME.
•0.5 to 12.0
Revertive time is 0.5 to 12.0 minutes.
<CMDMDE>
Command mode. Only applicable when creating or deleting a protection group (1:1 or 1:N) and/or adding cards to an existing protection group (1:N). Default is NORM. If creating or adding cards to a protection group, specifying FRCD requires the card to be physically plugged in and in the service state (IS). If removing cards from a protection group (1:N) or deleting the protection group (1:1, 1:N), specifying FRCD requires that there are no cross-connects (services) on the card.
The parameter type is CMDMDE, which forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied.
•FRCD
Force the system to override a state where the command would normally be denied.
•NORM
Execute the command normally. Do not override any conditions that might make the command fail.
<CARDMODE>
Card mode.
Note The card will reboot after the mode changes, so the mode change request will not go through if all the ports on the card are not in OOS mode.
Note TL1 will not set a default CARDMODE value at the management interface level if no PWL value is given.
The parameter type is CARDMODE (card mode). Card mode is applicable to cards that have multiple capabilities, for example, the ML-Series card can operate in two distinct modes: Linear Mapper Mode and L2/L3 Mode.
•AMPL-BST
The optical amplifier is working as an optical booster
•AMPL-PRE
The optical amplifier is working as an optical pre-amplifier
•DS1E1-DS1ONLY
DS1 mode on DS1E1 card.
•DS1E1-E1ONLY
E1 mode on DS1E1 card.
•DS3XM12-STS12
The DS3XM-12 card in the STS12 backplane rate mode
•DS3XM12-STS48
The DS3XM-12 card in the STS48 backplane rate mode
•DWDM-LINE
Line terminating mode
•DWDM-SECTION
Section terminating mode
•DWDM-TRANS-AIS
Transparent mode AIS
•DWDM-TRANS-SQUELCH
Transparent mode SQUELCH
•FCMR-DISTEXTN
FC_MR-4 card with distance extension support
•FCMR-LINERATE
FC_MR-4 card without distance extension support
•ML-GFP
ML-Series card in DOS field-programmable gate array (FPGA) using generic framing procedure (GFP) framing type
•ML-HDLC
ML-Series card in DOS FPGA using high-level data link control (HDLC) framing type
•MXPMR10DME-4GFC
4 Gbps Fibre Channel/FICON mode for the Cisco ONS 15454 10DME-C/10DME-L card supported on ports one and five
•MXPMR10DME-4GFC-FCGEISC
4 Gbps Fibre Channel/FICON supported on port one and Fibre Channel, GIGE and ISC modes for the Cisco ONS 15454 10DME-C/10DME-L card supported on ports five to eight
•MXPMR10DME-FCGEISC
Fibre Channel, GIGE and ISC modes for the Cisco ONS 15454 10DME-C/10DME-L card supported on all eight ports
•MXPMR10DME-FCGEISC-4GFC
Fibre Channel, GIGE and ISC modes for the Cisco ONS 15454 10DME-C/10DME-L card supported on ports one to four and 4 Gbps Fibre Channel/FICON supported on port five
•MXPMR10G-FCGEISC
Fibre Channel, GIGE and ISC modes for the Cisco ONS 15454 10DME-C10DME-L card supported on all 8 ports (MXP-MR-10DME)
•MXPMR10G-4GFC
4 Gbps Fibre Channel/FICON mode for the Cisco ONS 15454 10DME-C10DME-L card supported on ports 1 and 5 (MXP-MR-10DME)
•MXPMR10G-FCGEISC-4GFC
Fibre Channel, GIGE and ISC modes for the Cisco ONS 15454 10DME-C10DME-L card supported on ports 1 to 4 and 4 Gbps Fibre Channel/FICON supported on port 5 (MXP-MR-10DME)
•MXPMR10G-4GFC-FCGEISC
4 Gbps Fibre Channel/FICON supported on port 1 and Fibre Channel, GIGE and ISC Modes for the Cisco ONS 15454 10DME-C10DME-L card supported on ports 5 to 8 (MXP-MR-10DME)
•MXPMR25G-ESCON
ESCON mode for the Cisco ONS 15454 MXP_2.5G_10G card
•MXPMR25G-FCGE
Fibre channel or GIGE mode for the MXP_2.5G_10G card
•MXPMR25G-MIXED
Mixed Fibre Channel, GIGE and ESCON modes for the Cisco ONS 15454 MXP_2.5G_10G card
<PEERID>
The regeneration peer slot from the "EQPT" section.
<REGENNAME>
The name of a regeneration group. REGENNAME is a string.
<PWL>
Provisioned wavelength. TL1 will not set a default PWL value at the management level if no PWL value is given. The parameter type is OPTICAL_WLEN (optical wavelength),
•1310
Wavelength 1310
•1470
Wavelength 1470
•1490
Wavelength 1490
•1510
Wavelength 1510
•1529.55
Wavelength 1529.55
•1529.94
Wavelength 1529.94
•1530
Wavelength 1530
•1530.33
Wavelength 1530.33
•1530.73
Wavelength 1530.73
•1531.12
Wavelength 1531.12
•1531.51
Wavelength 1531.51
•1531.90
Wavelength 1531.90
•1532.29
Wavelength 1532.29
•1532.68
Wavelength 1532.68
•1533.07
Wavelength 1533.07
•1533.47
Wavelength 1533.47
•1533.86
Wavelength 1533.86
•1534.25
Wavelength 1534.25
•1534.64
Wavelength 1534.64
•1535.04
Wavelength 1535.04
•1535.43
Wavelength 1535.43
•1535.82
Wavelength 1535.82
•1536.22
Wavelength 1536.22
•1536.61
Wavelength 1536.61
•1537
Wavelength 1537
•1537.40
Wavelength 1537.40
•1537.79
Wavelength 1537.79
•1538.19
Wavelength 1538.19
•1538.58
Wavelength 1538.58
•1538.98
Wavelength 1538.98
•1539.37
Wavelength 1539.37
•1539.77
Wavelength 1539.77
•1540.16
Wavelength 1540.16
•1540.56
Wavelength 1540.56
•1540.95
Wavelength 1540.95
•1541.35
Wavelength 1541.35
•1541.75
Wavelength 1541.75
•1542.14
Wavelength 1542.14
•1542.35
Wavelength 1542.35
•1542.54
Wavelength 1542.54
•1542.94
Wavelength 1542.94
•1543.33
Wavelength 1543.33
•1543.73
Wavelength 1543.73
•1544.13
Wavelength 1544.13
•1544.53
Wavelength 1544.53
•1544.92
Wavelength 1544.92
•1545.32
Wavelength 1545.32
•1545.72
Wavelength 1545.72
•1546.12
Wavelength 1546.12
•1546.52
Wavelength 1546.52
•1546.92
Wavelength 1546.92
•1547.32
Wavelength 1547.32
•1547.72
Wavelength 1547.72
•1548.12
Wavelength 1548.12
•1548.51
Wavelength 1548.51
•1548.92
Wavelength 1548.92
•1549.32
Wavelength 1549.32
•1549.71
Wavelength 1549.71
•1550
Wavelength 1500
•1550.12
Wavelength 1550.12
•1550.52
Wavelength 1550.52
•1550.92
Wavelength 1550.92
•1551.32
Wavelength 1551.32
•1551.72
Wavelength 1551.72
•1552.12
Wavelength 1552.12
•1552.52
Wavelength 1552.52
•1552.93
Wavelength 1552.93
•1553.33
Wavelength 1553.33
•1553.73
Wavelength 1553.73
•1554.13
Wavelength 1554.13
•1554.13
Wavelength 1554.13
•1554.94
Wavelength 1554.94
•1555.34
Wavelength 1555.34
•1555.75
Wavelength 1555.75
•1556.15
Wavelength 1556.15
•1556.55
Wavelength 1556.55
•1556.96
Wavelength 1556.96
•1557.36
Wavelength 1557.36
•1557.77
Wavelength 1557.77
•1558.17
Wavelength 1558.17
•1558.58
Wavelength 1558.58
•1558.98
Wavelength 1558.98
•1559.39
Wavelength 1559.39
•1559.79
Wavelength 1559.79
•1560.20
Wavelength 1560.20
•1560.61
Wavelength 1560.61
•1561.01
Wavelength 1561.01
•1561.42
Wavelength 1561.42
•1561.83
Wavelength 1561.83
•1570
Wavelength 1570
•1570.83
Wavelength 1570.83
•1571.24
Wavelength 1571.24
•1571.65
Wavelength 1571.65
•1572.06
Wavelength 1572.06
•1572.48
Wavelength 1572.48
•1572.89
Wavelength 1572.89
•1573.30
Wavelength 1573.30
•1573.71
Wavelength 1573.71
•1574.13
Wavelength 1574.13
•1574.54
Wavelength 1574.54
•1574.95
Wavelength 1574.95
•1575.37
Wavelength 1575.37
•1575.78
Wavelength 1575.78
•1576.20
Wavelength 1576.20
•1576.61
Wavelength 1576.61
•1577.03
Wavelength 1577.03
•1577.44
Wavelength 1577.44
•1577.86
Wavelength 1577.86
•1578.27
Wavelength 1578.27
•1578.69
Wavelength 1578.69
•1579.10
Wavelength 1579.10
•1579.52
Wavelength 1579.52
•1579.93
Wavelength 1579.93
•1580.35
Wavelength 1580.35
•1580.77
Wavelength 1580.77
•1581.18
Wavelength 1581.18
•1581.60
Wavelength 1581.60
•1582.02
Wavelength 1582.02
•1582.44
Wavelength 1582.44
•1582.85
Wavelength 1582.85
•1583.27
Wavelength 1583.27
•1583.69
Wavelength 1583.69
•1584.11
Wavelength 1584.11
•1584.53
Wavelength 1584.53
•1584.95
Wavelength 1584.95
•1585.36
Wavelength 1585.36
•1585.78
Wavelength 1585.78
•1586.20
Wavelength 1586.20
•1586.62
Wavelength 1586.62
•1587.04
Wavelength 1587.04
•1587.46
Wavelength 1587.46
•1587.88
Wavelength 1587.88
•1588.30
Wavelength 1588.30
•1588.73
Wavelength 1588.73
•1589.15
Wavelength 1589.15
•1589.57
Wavelength 1589.57
•1589.99
Wavelength 1589.99
•1590
Wavelength 1590
•1590.41
Wavelength 1590.41
•1590.83
Wavelength 1590.83
•1591.26
Wavelength 1591.26
•1591.68
Wavelength 1591.68
•1592.10
Wavelength 1592.10
•1592.52
Wavelength 1592.52
•1592.95
Wavelength 1592.95
•1593.37
Wavelength 1593.37
•1593.79
Wavelength 1593.79
•1594.22
Wavelength 1594.22
•1594.64
Wavelength 1594.64
•1595.06
Wavelength 1595.06
•1595.49
Wavelength 1595.49
•1596.34
Wavelength 1596.34
•1596.76
Wavelength 1596.76
•1597.19
Wavelength 1597.19
•1597.62
Wavelength 1597.62
•1598.04
Wavelength 1598.04
•1598.47
Wavelength 1598.47
•1598.89
Wavelength 1598.89
•1599.32
Wavelength 1599.32
•1599.75
Wavelength 1599.75
•1600.06
Wavelength 1600.06
•1601.03
Wavelength 1601.03
•1601.46
Wavelength 1601.46
•1601.88
Wavelength 1601.88
•1602.31
Wavelength 1602.31
•1602.74
Wavelength 1602.74
•1603.17
Wavelength 1603.17
•1603.60
Wavelength 1603.60
•1604.03
Wavelength 1604.03
•1610
Wavelength 1610
•USE-TWL1
Use Tunable Wavelength 1
<RETIME>
Indicates if retiming is needed. Applicable only to the DS1/E1-56 card (ONS 15454). The parameter type is YES_NO, which indicates whether the user's password is about to expire, the user is logged into the NE, or the user is locked out of the NE.
•NO
No
•YES
Yes
<SHELFROLE>
The role of the shelf in the context of the node. When it is omitted it defaults to SC. The parameter is SHELF_ROLE.
•NC
The shelf behaves as a node controller.
•SC
The shelf behaves as a shelf controller.
<NEWSHELFID>
(Optional) New shelf identifier is used to change the value of the shelf identifier for the addressed shelf. The value must be different by one and can be in the range from two to eight. This field can only be changed if (in the same command) the SHELFROLE is equal to SC. Integer.
<PST>
Primary state. The parameter type is PST, which indicates the current overall service condition of an entity.
•IS
In service
•OOS
Out of service
<SST>
Secondary state. The parameter type is SST, which provides additional information pertaining to PST and PSTQ.
•AINS
Automatic in-service
•DSBLD
Disabled
•LPBK
Loopback
•MEA
Mismatch of equipment and attributes
•MT
Maintenance mode
•OOG
Out of group
•SWDL
Software downloading
•UAS
Unassigned
•UEQ
Unequipped
11.18 ED-FAC
(Cisco ONS 15454, ONS 15327, ONS 15310-CL, ONS 15310-MA, ONS 15600) The Edit Facility (ED-FAC) command provisions the payload (or signal) type of facility. The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. In order to obtain the current value, issue the RTRV-XX command to retrieve them.
Usage Guidelines
None
CategoryPorts
SecurityProvisioning
Input FormatED-FAC:[<TID>]:<SRC>:<CTAG>:::[PAYLOAD=<PAYLOAD>],
[CMDMDE=<CMDMDE>]:[<PST>[,<SST>]];Input ExampleED-FAC:CISCO:FAC-3-9:2222:::PAYLOAD=E4-FRAMED,CMDMDE=CMDMDE:IS,AINS;
Input Parameters
<SRC>
Source access identifier from the "FACILITY" section.
<PAYLOAD>
The payload for the card. The parameter type is PAYLOAD, which identifies the payload type.
•10GFC
10 Gigabit Ethernet Fibre Channel mode
•10GIGE
10 Gigabit Ethernet
•1GFC
1 Gigabit Fibre Channel mode
•1GFICON
1 Gigabit FICON mode
•2GFC
2 Gigabit Fibre Channel mode
•2GFICON
2 Gigabit FICON mode
•DS3
DS3 mode
•DV6000
Video mode
•EC1
EC1 mode
•ESCON
ESCON mode
•ETRCLO
ETR/CLO payload mode
•GIGE
Gigabit Ethernet Payload
•HDTV
HDTV mode
•ISC1
ISC1 Mode
•ISC3
ISC3 Mode
•OC12
SONET OC-12 mode
•OC3
SONET OC-3 mode
•OC48
SONET OC-48 mode
•PASS-THROUGH
Pass through mode
•SDI-D1-VIDEO
SDI-D1-Video mode
•SONET
SONET Payload Mode
CMDMDE
Command Mode. Defaults to NORM. The parameter type is CMDMDE, which forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied.
•FRCD
Force the system to override a state where the command would normally be denied.
•NORM
Execute the command normally. Do not override any conditions that might make the command fail.
PST
Primary state. Defaults to IS. The parameter type is PST, which indicates the current overall service condition of an entity.
•IS
In service
•OOS
Out of service
SST
Secondary state. Defaults to AINS. The parameter type is SST, which provides additional information pertaining to PST and PSTQ.
•AINS
Automatic in-service
•DSBLD
Disabled
•LPBK
Loopback
•MEA
Mismatch of equipment and attributes
•MT
Maintenance mode
•OOG
Out of group
•SWDL
Software downloading
•UAS
Unassigned
•UEQ
Unequipped
11.19 ED-FFP-<MOD2DWDMPAYLOAD>
(Cisco ONS 15454) The Edit Facility Protection Group for 10GFC, 10GIGE, 1GFC, 1GFICON, 2GFC, 2GFICON, D1VIDEO, DV6000, ETRCLO, GIGE, HDTV, or ISC1 (ED-FFP-<MOD2DWDMPAYLOAD>) command edits a Y-cable protection group on client facilities.
Usage Guidelines
None
CategoryDWDM
SecurityProvisioning
Input FormatED-FFP-<MOD2DWDMPAYLOAD>:[<TID>]:<AID>:<CTAG>:::[PROTID=<PROTID>],
[RVRTV=<RVRTV>],[RVTM=<RVTM>],[PSDIRN=<PSDIRN>][:];Input ExampleED-FFP-CLNT:CISCO:FAC-1-1:100:::PROTID=DC-METRO,RVRTV=N,RVTM=1.0,PSDIRN=BI;
Input Parameters
<AID>
Access identifier from the "FACILITY" section.
<PROTAID>
The protection group identifier (protection group name). Defaults to the protecting port AID of the protection group. PROTAID can have a maximum length of 32 characters. It is a string.
<RVRTV>
Revertive mode. The value Y indicates that the protection switching system reverts service to the original line after restoration. The value N indicates that the protection switching system does not revert service to the original line after restoration. RVRTV is applicable only for 1+1 protection switching. Null defaults to N. Only applies to path protection configurations. The parameter type is ON_OFF, which disables or enables an attribute.
•N
Disable an attribute.
•Y
Enable an attribute.
RVTM
Revertive time. RVTM is not allowed to be set while "RVRTV" is N. Only applies to path protection configurations. The parameter type is REVERTIVE_TIME (revertive time).
•0.5 to 12.0
Revertive time is 0.5 to 12.0 minutes.
PSDIRN
Protection switch operation. Identifies the switching mode. Defaults to UNI.
Note The MXP_2.5G_10G and TXP_MR_10G cards do not support bidirectional switching.
The parameter type is UNI_BI (unidirectional switch operations).
•BI
Bidirectional protection switching
•UNI
Unidirectional protection switching
11.20 ED-FFP-<OCN_TYPE>
(Cisco ONS 15454, ONS 15327, ONS 15310-CL, ONS 15310-MA, ONS 15600) The Edit Facility Protection Group for OC3, OC12, OC48, or OC192 (ED-FFP-<OCN_TYPE>) command edits the optical facility protection.
Usage Guidelines
See Table 27-1 for supported modifiers by platform.
Note•This command can be used on both protecting and working AIDs. Optimized 1+1 and related attributes are only applicable to the ONS 15454.
•Optimized 1+1 and related attributes are only applicable to ONS 15454.
•The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. In order to obtain the current value, issue the RTRV-XX command to retrieve them.
CategoryProtection
SecurityProvisioning
Input FormatED-FFP-<OCN_TYPE>:[<TID>]:<AID>:<CTAG>:::[PROTID=<PROTID>],
[RVRTV=<RVRTV>],[RVTM=<RVTM>],[PSDIRN=<PSDIRN>],[VRGRDTM=<VRGRDTM>],
[DTGRDTM=<DTGRDTM>],[RCGRDTM=<RCGRDTM>][:];Input ExampleED-FFP-OC3:PETALUMA:FAC-1-1:1:::PROTID=PROT_NAME,RVRTV=Y,RVTM=1.0,
PSDIRN=BI,VRGRDTM=0.5,DTGRDTM=1.0,RCGRDTM=1.0;Input Parameters
<AID>
Access identifier from the "FACILITY" section.
<PROTAID>
The protection group identifier (protection group name). PROTAID can have a maximum length of 32 characters. It is a string.
<RVRTV>
Revertive mode. The value Y indicates that the protection switching system reverts service to the original line after restoration. The value N indicates that the protection switching system does not revert service to the original line after restoration. RVRTV is applicable only for 1+1 protection switching. Null defaults to N. The parameter type is ON_OFF, which disables or enables an attribute.
•N
Disable an attribute.
•Y
Enable an attribute.
<RVTM>
Revertive time. The parameter type is REVERTIVE_TIME (revertive time).
•0.5 to 12.0
Revertive time is 0.5 to 12.0 minutes.
<PSDIRN>
Protection switch operation. Indicates the switch mode. Defaults to UNI. The parameter type is UNI_BI (unidirectional and bidirectional switch operations).
•BI
Bidirectional protection switching
•UNI
Unidirectional protection switching
<VRGRDTM>
Verification guard timer. Only applicable to optimized 1+1. The parameter type is VERIFICATION_GUARD_TIMER (optimized 1+1 verification guard timer).
•0.5
500 ms
•1.0
1 second
<DTGRDTM>
Detection guard timer. Only applicable to optimized 1+1. The parameter type is DETECTION _GUARD_TIMER (optimized 1+1 detection guard timer).
•0.0
0 seconds
•0.05
50 ms
•0.1
100 ms
•0.5
500 ms
•1.0 to 5.0
1 second to 5 seconds
<RCGRDTM>
Recovery guard timer. Only applicable to optimized 1+1. The parameter type is RECOVERY_GUARD_TIMER (optimized 1+1 recovery guard timer).
•0.0
0 seconds
•0.05
50 ms
•0.1
100 ms
•0.5
500 ms
•1.0 to 10.0
1 second to 10 seconds
11.21 ED-FFP-OCH
(Cisco ONS 15454) The Edit Facility Protection Group Optical Channel (ED-FFP-OCH) command changes the provisioning for the default protection group on the DWDM port of a TXP_MR_2.5G and TXPP_MR_2.5G card.
Usage Guidelines
None
CategoryDWDM
SecurityProvisioning
Input FormatED-FFP-OCH:[<TID>]:<AID>:<CTAG>:::[PROTID=<PROTID>],[RVRTV=<RVRTV>],
[RVTM=<RVTM>],[PSDIRN=<PSDIRN>][:];Input ExampleED-FFP-OCH:VA454-22:CHAN-2-2:100:::PROTID="FIXEDPROTECTION",RVRTV=N,
RVTM=1.0,PSDIRN=BI;Input Parameters
<AID>
Access identifier from the "CHANNEL" section.
<PROTAID>
The protection group identifier (protection group name). PROTAID is a string.
<RVRTV>
Revertive mode. The value Y indicates that the protection switching system reverts service to the original line after restoration. The value N indicates that the protection switching system does not revert service to the original line after restoration. RVRTV is applicable only for 1+1 protection switching. Null defaults to N. The parameter type is ON_OFF, which disables or enables an attribute.
•N
Disable an attribute.
•Y
Enable an attribute.
<RVTM>
Revertive time. The parameter type is REVERTIVE_TIME (revertive time).
•0.5 to 12.0
Revertive time is 0.5 to 12.0 minutes
<PSDIRN>
Protection switch operation. The parameter type is TRANS_MODE (G1000 transponder mode)
•BI
Bidirectional
•NONE
Not in transponder mode
•UNI
Unidirectional
11.22 ED-FSTE
(Cisco ONS 15454, ONS 15310-CL, ONS 15310-MA) The Edit Fast Ethernet (ED-FSTE) command edits the front-end port information of the fast (10/100 Mbps) Ethernet card
Usage Guidelines
The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. In order to obtain the current value, issue the RTRV-XX command to retrieve them.
Note For the ML-100T-8 card, only the NAME parameter can be set.
CategoryPorts
SecurityProvisioning
Input FormatED-FSTE:[<TID>]:<AID>:<CTAG>:::[FLOW=<FLOW>],[EXPDUPLEX=<EXPDUPLEX>],
[EXPSPEED=<EXPSPEED>],[VLANCOS=<VLANCOS>],[IPTOS=<IPTOS>],
[NAME=<NAME>],[CMDMDE=<CMDMDE>],[SOAK=<SOAK>]:[<PST>[,<SST>]];Input ExampleED-FSTE:CISCO:FAC-1-1:123:::FLOW=FLOW,EXPDUPLEX=EXPDUPLEX,
EXPSPEED=EXPSPEED, VLANCOS=VLANCOS,IPTOS=IPTOS,
NAME="FSTE PORT",CMDMDE=CMDMDE,SOAK=32:IS,AINS;Input Parameters
<AID>
Access identifier from the "FACILITY" section.
<FLOW>
Flow control. The parameter type is ON_OFF, which disables or enables an attribute.
•N
Disable an attribute.
•Y
Enable an attribute.
<EXPDUPLEX>
Ethernet duplex mode. The parameter type is ETHER_DUPLEX (duplex mode).
•AUTO
Auto mode
•FULL
Full mode
•HALF
Half mode
<EXPSPEED>
Ethernet speed. The parameter type is ETHER_SPEED (Ethernet speed).
•100_MBPS
100 Mbps
•10_GBPS
10 Gbps
•10_MBPS
10 Mbps
•1_GBPS
1 Gbps
•AUTO
Auto
<VLANCOS>
Priority queuing threshold based on VLAN class of service of incoming Ethernet packets. Default value is 1175. VLANCOS is an integer.
<IPTOS>
Priority queuing threshold based on IP type of service of incoming Ethernet packets. Default value is 368. IPTOS is an integer.
<NAME>
Name. NAME is a string.
<CMDMDE>
Command Mode. The FRCD mode of operation is applicable to delete a VCAT member cross-connect from IS-NR or OOS-AU,AINS service state. The parameter type is CMDMDE, which forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied.
•FRCD
Force the system to override a state where the command would normally be denied.
•NORM
Execute the command normally. Do not override any conditions that might make the command fail.
<SOAK>
OOS-AINS to IS transition soak time as measured in 15 minute intervals, so a value of 4 translates to a soak time of 1 hour. The allowable range is 0 to 192 intervals (maximum of 48 hours). SOAK is an integer.
<PST>
Primary state. The parameter type is PST, which indicates the current overall service condition of an entity.
•IS
In service
•OOS
Out of service
<SST>
Secondary state. The parameter type is SST, which provides additional information pertaining to PST and PSTQ.
•AINS
Automatic in-service
•DSBLD
Disabled
•LPBK
Loopback
•MEA
Mismatch of equipment and attributes
•MT
Maintenance mode
•OOG
Out of group
•SWDL
Software downloading
•UAS
Unassigned
•UEQ
Unequipped
11.23 ED-G1000
(Cisco ONS 15454) The Edit G1000 (ED-G1000) command edits the attributes related to a G1000 port.
Usage Guidelines
The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. In order to obtain the current value, issue the RTRV-XX command.
CategoryPorts
SecurityProvisioning
Input FormatED-G1000:[<TID>]:<AID>:<CTAG>:::[MFS=<MFS>],[FLOW=<FLOW>],
[LOWMRK=<LOWMRK>],[HIWMRK=<HIWMRK>],[AUTONEG=<AUTONEG>],
[NAME=<NAME>],[CMDMDE=<CMDMDE>],[SOAK=<SOAK>]:[<PST>[,<SST>]];Input ExampleED-G1000:TID:FAC-1-1:CTAG:::MFS=1548,FLOW=Y,LOWMRK=20,HIWMRK=492,
AUTONEG=Y,NAME="G1000 PORT",CMDMDE=FRCD,SOAK=32:OOS,DSBLD;Input Parameters
<AID>
Access identifier from the "FACILITY" section.
<MFS>
Maximum frame size. the parameter type is MFS_TYPE, which is the maximum frame size used by an Ethernet card.
•1548
Normal frame size
•JUMBO
Jumbo frame size
<FLOW>
Flow control. The parameter type is ON_OFF, which disables or enables an attribute.
•N
Disable an attribute.
•Y
Enable an attribute.
<LOWMRK>
Low watermark value. LOWMRK is an integer. Defaults to 25. LOWMRK is available in Software Release 4.0.1 and later.
<HIWMRK>
High watermark value. HIWMRK is an integer. Defaults to 485.
<AUTONEG>
Automatic negotiation. Defaults to Y. The parameter type is ON_OFF, which disables or enables an attribute.
•N
Disable an attribute.
•Y
Enable an attribute.
<NAME>
Name. NAME is a string. Default is NULL. Maximum length is 32 characters.
<CMDMDE>
Command execution mode. The parameter type is CMDMDE, which forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied.
•FRCD
Force the system to override a state where the command would normally be denied.
•NORM
Execute the command normally. Do not override any conditions that might make the command fail.
<SOAK>
OOS-AINS to IS transition soak time as measured in 15-minute intervals. A value of 4 equals a soak time of 1 hour. The allowable range is 0 to 192 intervals (maximum of 48 hours). SOAK is an integer. Defaults to 32.
<ENCAP>
Encapsulation. ENCAP is a string.
<PST>
Primary state. Defaults to OOS. The parameter type is PST, which indicates the current overall service condition of an entity.
•IS
In service
•OOS
Out of service
<SST>
Secondary state. Defaults to DSBLD. The parameter type is SST, which provides additional information pertaining to PST and PSTQ.
•AINS
Automatic in-service
•DSBLD
Disabled
•LPBK
Loopback
•MEA
Mismatch of equipment and attributes
•MT
Maintenance mode
•OOG
Out of group
•SWDL
Software downloading
•UAS
Unassigned
•UEQ
Unequipped
11.24 ED-GFP
(Cisco ONS 15454, ONS 15310-CL, ONS 15310-MA, ONS 15600) The Edit Generic Framing Protocol (ED-GFP) command applies to the ONS 15454 CE-100T-8 card, FC_MR-4 card, and CE-1000-4 card, the ONS 15310-CL CE-100T-8 card, and the ONS 15600 ASAP card. It changes GFP parameters.
Usage Guidelines
•The ONS 15600 only supports the TID, AID, CTAG, and FCS parameters.
•This command does not apply to the ONS 15310-CL ML-100T-8 card.
•For the FC_MR-4 card, the parameters AUTOTHGFPBUF, GFPBUF, and FILTER can be edited only if distance extension is enabled (set to B2B).
CategoryPorts
SecurityProvisioning
Input FormatED-GFP:[<TID>]:<AID>:<CTAG>:::[FCS=<FCS>],[AUTOTHGFPBUF=<AUTOTHGFPBUF>],
[GFPBUF=<GFPBUF>],[FILTER=<FILTER>];Input ExampleED-GFP:CISCO:VFAC-1-0:123:::FCS=N,AUTOTHGFPBUF=Y,GFPBUF=16,FILTER=EGRESS;
Input Parameters
<AID>
Access identifier from the "FACILITY" section.
Note VFAC AID is used for the CE-100T-8 cards on the ONS 15310-CL and ONS 15454 and for the ASAP cards on the ONS 15600. ML-100T-8 GFP management is done through the Cisco IOS command-line interface (CLI) and not through the TL1 interface. The FAC AID is used for the ONS 15454 FC_MR-4.
<FCS>
Payload frame check sequence. The parameter type is FCS (frame check sequence).
•FCS-16
Frame check sequencing using 16 bits
•FCS-32
Frame check sequencing using 32 bits
•NONE
No frame check sequence
<AUTOTHGFPBUF>
The parameter type is ON_OFF, which disables or enables an attribute.
•N
Disable an attribute.
•Y
Enable an attribute.
<FILTER>
The parameter type is GFP_FILTER, which is the filter feature in GFP.
•EGRESS
Activate filter feature on egress port.
•NONE
Turn off filter feature.
11.25 ED-HDLC
(Cisco ONS 15600) The Edit High-Level Data Link Control (ED-HDLC) command edits HDLC-related attributes for HDLC-encapsulated payloads.
Usage Guidelines
None
CategoryPorts
SecurityProvisioning
Input FormatED-HDLC:[<TID>]:<SRC>:<CTAG>[:::FCS=<FCS>];
Input ExampleED-HDLC:TID:VFAC-SLOT-PORT:CTAG:::FCS=FCS-16;
Input Parameters
<SRC>
Access identifier from the "FACILITY" section. The ONS 15600 ASAP card uses the VFAC AID.
<FCS>
Payload frame check sequence. The parameter type is FCS (frame check sequence).
•FCS-16
Frame check sequence using 16 bits
•FCS-32
Frame check sequence using 32 bits
•NONE
No frame check sequence
11.26 ED-LNK
(Cisco ONS 15454) The Edit Link (ED-LNK) command edits an optical link state.
Usage Guidelines
The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. In order to obtain the current value, issue the RTRV-XX command.
CategoriesDWDM
SecurityProvisioning
Input FormatED-LNK:[<TID>]:<FROM>,<TO>:<CTAG>:::[CMDMDE=<CMDMDE>]:
[<PST>[,<SST>]];Input ExampleED-LNK:PENNGROVE:BAND-6-1-TX,BAND-13-1-RX:114:::CMDMDE=CMDMDE:
IS,AINS;Input Parameters
<FROM>
Identifier at one end of the optical link from the "BAND" section.
<TO>
Identifier at the other end of the optical link from the "BAND" section.
<CMDMDE>
Command Mode. The FRCD mode of operation is applicable to delete a VCAT member cross-connect from IS-NR or OOS-AU,AINS service state.
The parameter type is CMDMDE, which forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied.
•FRCD
Force the system to override a state where the command would normally be denied.
•NORM
Execute the command normally. Do not override any conditions that might make the command fail.
<PST>
Primary state.
Note PST is not supported for optical channel (OCH) provisioning.
The parameter type is PST, which indicates the current overall service condition of an entity.
•IS
In service
•OOS
Out of service
<SST>
Secondary state.
Note SST is not supported for OCH provisioning.
The parameter type is SST, which provides additional information pertaining to PST and PSTQ.
•AINS
Automatic in-service
•DSBLD
Disabled
•LPBK
Loopback
•MEA
Mismatch of equipment and attributes
•MT
Maintenance mode
•OOG
Out of group
•SWDL
Software downloading
•UAS
Unassigned
•UEQ
Unequipped
11.27 ED-LNKTERM
(Cisco ONS 15454, ONS 15327, ONS 15310-CL) The Edit Provisionable Patchcord Termination (ED-LNKTERM) command edits the attributes of a provisionable patchcord that has already been created. Only the remote end attributes (REMOTENODE and REMOTELNKTERMID) can be edited.
Usage Guidelines
•No two provisionable patchcord terminations on a node can have the same remote end link termination information. An attempt to modify an existing provisionable patchcord termination while not following this restriction will lead to an error message being responsed.
•If the provisionable patchcord termination does not exist, an error message will be responsed.
•This command does not accept multiple and ALL AIDs.
•REMOTENODE is a string with a maximum length of 20 characters.
CategoryProvisionable Patchcords
SecurityProvisioning
Input FormatED-LNKTERM:[<TID>]:<AID>:<CTAG>:::[REMOTENODE=<REMOTENODE>],
[REMOTELNKTERMID=<REMOTELNKTERMID>];Input ExampleED-LNKTERM::LNKTERM-1:CTAG:::REMOTENODE=172.20.208.226,
REMOTELNKTERMID=25;Input Parameters
<AID>
Access identifier from the "LNKTERM" section. Indicates a link (provisionable patchcord) termination on the local node.
<REMOTENODE>
The node where the other end of the provisionable patchcord resides. This can be an IP address or a valid TID. Defaults to the IP address of the local node/existing value. REMOTENODE is a string.
<REMOTELNKTERMID>
The corresponding provisionable patchcord termination on the remote node (as specified by the REMOTENODE parameter). Integer value within the range of 1 to 65535. Defaults to the existing value.
11.28 ED-NE-GEN
(Cisco ONS 15454, ONS 15327, ONS 15310-CL, ONS 15310-MA, ONS 15600) The Edit Network Element General (ED-NE-GEN) command edits the node attributes of the NE.
Usage Guidelines
•The node name can be a maximum of 20 characters. If the entered name exceeds 20 characters, an IPNV (Node Name Too Long) error message is returned.
•An existing NTP timing source can be removed by setting the address to 0.0.0.0.
•The maximum length of IPADDR and DEFRTR is 20 characters. The default value is the local IP address and default router.
•The maximum length of IPMASK is 18 characters. The default is the mask of the local IP address.
•ETHIPADDR and ETHIPMASK are disabled in this command. ETHIPADDR and ETHIPMASK are used to show the Ethernet interface address and mask. Both default to the nodes' IP address and masks.
•The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. In order to obtain the current value, issue the RTRV-XX command.
Caution Changing the IPADDR, IPMASK, or IIOPPORT will cause a reset of the controller card.
CategorySystem
SecuritySuperuser
Input FormatED-NE-GEN:[<TID>]::<CTAG>:::[NAME=<NAME>],[IPADDR=<IPADDR>],
[IPMASK=<IPMASK>],[DEFRTR=<DEFRTR>],[IIOPPORT=<IIOPPORT>],
[NTP=<NTP>],[ISPROXYSERVER=<ISPROXYSERVER>],[ISFIREWALL=<ISFIREWALL>],
[SUPPRESSIP=<SUPPRESSIP>],[MODE=<MODE>];Input ExampleED-NE-GEN:CISCO::123:::NAME=NODENAME,IPADDR=192.168.100.52,
IPMASK=255.255.255.0,DEFRTR=192.168.100.1,IIOPPORT=57790,
NTP=192.168.100.52,ISPROXYSERVER=YES,ISFIREWALL=YES,SUPPRESSIP=NO,
MODE=SINGLESHELF;Input Parameters
11.29 ED-NE-PATH
(Cisco ONS 15454, ONS 15327, ONS 15310-CL, ONS 15310-MA) The Edit Network Element Path (ED-NE-PATH) command edits the path attributes of the NE.
Usage Guidelines
The default value for an optional parameter is the NE default value.
CategorySystem
SecurityProvisioning
Input FormatED-NE-PATH:[<TID>]::<CTAG>:::[PDIP=<PDIP>],[XCMODE=<XCMODE>];
Input ExampleED-NE-PATH:::CTAG:::PDIP=Y,XCMODE=MIXED;
Input Parameters
11.30 ED-NE-SYNCN
(Cisco ONS 15454, ONS 15327, ONS 15310-CL, ONS 15310-MA, ONS 15600) The Edit Network Element Synchronization (ED-NE-SYNCN) command edits the synchronization attributes of the NE.
Usage Guidelines
The existing external and line modes have the same functionality in all ONS 15454 4.x and 5.x releases:
•External mode: The node derives its timing from the BITS inputs.
•Line mode: The node derives its timing from the SONET line(s).
•Mixed mode: The node derives its timing from the BITS input or SONET lines.
Note Although mixed mode timing is supported in this release, it is not recommended. Refer to the Cisco ONS SONET TL1 Reference Guide for more information.
CategorySynchronization
SecurityProvisioning
Input FormatED-NE-SYNCN:[<TID>]:[<AID>]:<CTAG>:::[TMMD=<TMMD>],[SSMGEN=<SSMGEN>],
[QRES=<QRES>],[RVRTV=<RVRTV>],[RVTM=<RVTM>];Input ExampleED-NE-SYNCN:CISCO::123:::TMMD=LINE,SSMGEN=GEN1,QRES=ABOVE-PRS,RVRTV=Y,
RVTM=8.0;ED-NE-SYNCN:CISCO:SHELF-2:123:::TMMD=LINE,SSMGEN=GEN1,QRES=ABOVE-PRS,
RVRTV=Y,RVTM=8.0;Input Parameters
<AID>
The node or shelf access identifier from the "SHELF" section. If omitted it addresses the node or first shelf of the node. Must not be null.
<TMMD>
Timing mode. A null value is equivalent to ALL. Defaults to EXTERNAL. The parameter type is TIMING_MODE, which is the timing mode for the current node.
•EXTERNAL
The node derives its clock from the BITS input.
•LINE
The node derives its clock from the SONET lines.
•MIXED
The node derives its clock from the mixed timing mode.
<SSMGEN>
Synchronization status message set. Defaults to GEN1. A null value is equivalent to ALL. The default is ABOVE-STU. The parameter type is SYNC_GENERATION (synchronization status message set generation).
•GEN1
First generation SSM set
•GEN2
Second generation SSM set
<QRES>
Quality of the RES. A null value is equivalent to ALL. Defaults to DUS. The parameter type is SYNC_QUALITY_LEVEL, which is the network synchronization quality level.
•ABOVE-PRS
Better than primary reference source. Valid setting for Generation-1 and Generation-2 SSM Set.
•ABOVE-SMC
Between SMC and ST3. Valid setting for Generation-1 and Generation-2 SSM Set.
•ABOVE-ST2
Between ST2 and STU. Valid setting for Generation-1 and Generation-2 SSM Set.
•ABOVE-ST3
For Generation-1 SSM set, between ST3 and ST2. For Generation-2 SSM set, between ST3 and ST3E.
•ABOVE-ST3E
Between ST3E and TNC. Valid setting only for Generation-2 SSM set.
•ABOVE-ST4
Between ST4 and ST3. Valid setting for Generation-1 and Generation-2 SSM Set.
•ABOVE-STU
Between STU and PRS. Valid setting for Generation-1 and Generation-2 SSM Set. This is default setting.
•ABOVE-TNC
Between TNC and ST2. Valid setting only for Generation-2 SSM set.
•BELOW-ST4
Below ST4 but still usable. Valid setting for Generation-1 and Generation-2 SSM Set.
•SAME-AS-DUS
Disable the RES message by equating it to DUS. Valid setting for Generation-1 and Generation-2 SSM Set.
<RVRTV>
Revertive mode. The value Y indicates that the protection switching system reverts service to the original line after restoration. The value N indicates that the protection switching system does not revert service to the original line after restoration. RVRTV is applicable only for 1+1 protection switching. Null defaults to N. A null value is equivalent to ALL. The parameter type is ON_OFF, which disables or enables an attribute.
•N
Disable an attribute.
•Y
Enable an attribute.
<RVTM>
Revertive time. A null value is equivalent to ALL. The parameter type is REVERTIVE_TIME (revertive time).
•0.5 to 12.0
Revertive time is 0.5 to 12.0 minutes.
11.31 ED-OCH
(Cisco ONS 15454) The Edit Optical Channel (ED-OCH) command edits the attributes (service parameters) and state of an OCH facility. Refer to the Cisco ONS SONET TL1 Reference Guide for specific card provisioning rules.
Usage Guidelines
Primary=OOS and secondary=AINS states do not apply to Ethernet mode.
CategoryDWDM
SecurityProvisioning
Input FormatED-OCH:[<TID>]:<AID>:<CTAG>:::[RDIRN=<RDIRN>],[EXPWLEN=<EXPWLEN>],
[VOAATTN=<VOAATTN>],[VOAPWR=<VOAPWR>],[CALOPWR=<CALOPWR>],
[CHPOWER=<CHPOWER>],[NAME=<PORTNAME>],[SFBER=<SFBER>],[SDBER=<SDBER>],
[COMM=<COMM>],[GCCRATE=<GCCRATE>],[OSDBER=<OSDBER>],[DWRAP=<DWRAP>],
[FEC=<FEC>],[PAYLOADMAP=<PAYLOADMAP>],[MACADDR=<MACADDR>],
[SYNCMSG=<SYNCMSG>],[SENDDUS=<SENDDUS>],[SOAK=<SOAK>],[OSPF=<OSPF>],
[MFS=<MFS>],[CMDMDE=<CMDMDE>]:[<PST>[,<SST>]];Input ExampleED-OCH:CISCO:CHAN-6-2:114:::RDIRN=W-E,EXPWLEN=1530.32,VOAATTN=2.5,
VOAPWR=7.5,CALOPWR=0,CHPOWER=2.0,NAME="NYLINE",SFBER=1E-5,
SDBER=1E-6,COMM=DCC,GCCRATE=192K,OSDBER=1E-6,DWRAP=Y,FEC=STD,
PAYLOADMAP=ASYNCH,MACADDR=00-0E-AA-BB-CC-DD,SYNCMSG=N,
SENDDUS=Y,SOAK=10,OSPF=Y,MFS=2152,CMDMDE=CMDMDE:IS,AINS;Input Parameters
AID
Access identifier from the "CHANNEL" section.
RDIRN
Ring directionality of the optical line. The parameter type is RDIRN_MODE, which is the optical ring directionality.
•E-W
The direction of the signal is from east to west (clockwise).
•W-E
The direction of the signal is from west to east (counterclockwise).
EXPWLEN
Optical wavelength for this port. Applicable only to the following cards: optical service channel cards, optical amplifier cards, dispersion compensation units, multiplexer cards, demultiplexer cards and optical add/drop multiplexing (OADM) cards. The parameter type is OPTICAL_WLEN (optical wavelength).
•1310
Wavelength 1310
•1470
Wavelength 1470
•1490
Wavelength 1490
•1510
Wavelength 1510
•1529.55
Wavelength 1529.55
•1529.94
Wavelength 1529.94
•1530
Wavelength 1530
•1530.33
Wavelength 1530.33
•1530.73
Wavelength 1530.73
•1531.12
Wavelength 1531.12
•1531.51
Wavelength 1531.51
•1531.90
Wavelength 1531.90
•1532.29
Wavelength 1532.29
•1532.68
Wavelength 1532.68
•1533.07
Wavelength 1533.07
•1533.47
Wavelength 1533.47
•1533.86
Wavelength 1533.86
•1534.25
Wavelength 1534.25
•1534.64
Wavelength 1534.64
•1535.04
Wavelength 1535.04
•1535.43
Wavelength 1535.43
•1535.82
Wavelength 1535.82
•1536.22
Wavelength 1536.22
•1536.61
Wavelength 1536.61
•1537
Wavelength 1537
•1537.40
Wavelength 1537.40
•1537.79
Wavelength 1537.79
•1538.19
Wavelength 1538.19
•1538.58
Wavelength 1538.58
•1538.98
Wavelength 1538.98
•1539.37
Wavelength 1539.37
•1539.77
Wavelength 1539.77
•1540.16
Wavelength 1540.16
•1540.56
Wavelength 1540.56
•1540.95
Wavelength 1540.95
•1541.35
Wavelength 1541.35
•1541.75
Wavelength 1541.75
•1542.14
Wavelength 1542.14
•1542.35
Wavelength 1542.35
•1542.54
Wavelength 1542.54
•1542.94
Wavelength 1542.94
•1543.33
Wavelength 1543.33
•1543.73
Wavelength 1543.73
•1544.13
Wavelength 1544.13
•1544.53
Wavelength 1544.53
•1544.92
Wavelength 1544.92
•1545.32
Wavelength 1545.32
•1545.72
Wavelength 1545.72
•1546.12
Wavelength 1546.12
•1546.52
Wavelength 1546.52
•1546.92
Wavelength 1546.92
•1547.32
Wavelength 1547.32
•1547.72
Wavelength 1547.72
•1548.12
Wavelength 1548.12
•1548.51
Wavelength 1548.51
•1548.92
Wavelength 1548.92
•1549.32
Wavelength 1549.32
•1549.71
Wavelength 1549.71
•1550
Wavelength 1500
•1550.12
Wavelength 1550.12
•1550.52
Wavelength 1550.52
•1550.92
Wavelength 1550.92
•1551.32
Wavelength 1551.32
•1551.72
Wavelength 1551.72
•1552.12
Wavelength 1552.12
•1552.52
Wavelength 1552.52
•1552.93
Wavelength 1552.93
•1553.33
Wavelength 1553.33
•1553.73
Wavelength 1553.73
•1554.13
Wavelength 1554.13
•1554.13
Wavelength 1554.13
•1554.94
Wavelength 1554.94
•1555.34
Wavelength 1555.34
•1555.75
Wavelength 1555.75
•1556.15
Wavelength 1556.15
•1556.55
Wavelength 1556.55
•1556.96
Wavelength 1556.96
•1557.36
Wavelength 1557.36
•1557.77
Wavelength 1557.77
•1558.17
Wavelength 1558.17
•1558.58
Wavelength 1558.58
•1558.98
Wavelength 1558.98
•1559.39
Wavelength 1559.39
•1559.79
Wavelength 1559.79
•1560.20
Wavelength 1560.20
•1560.61
Wavelength 1560.61
•1561.01
Wavelength 1561.01
•1561.42
Wavelength 1561.42
•1561.83
Wavelength 1561.83
•1570
Wavelength 1570
•1570.83
Wavelength 1570.83
•1571.24
Wavelength 1571.24
•1571.65
Wavelength 1571.65
•1572.06
Wavelength 1572.06
•1572.48
Wavelength 1572.48
•1572.89
Wavelength 1572.89
•1573.30
Wavelength 1573.30
•1573.71
Wavelength 1573.71
•1574.13
Wavelength 1574.13
•1574.54
Wavelength 1574.54
•1574.95
Wavelength 1574.95
•1575.37
Wavelength 1575.37
•1575.78
Wavelength 1575.78
•1576.20
Wavelength 1576.20
•1576.61
Wavelength 1576.61
•1577.03
Wavelength 1577.03
•1577.44
Wavelength 1577.44
•1577.86
Wavelength 1577.86
•1578.27
Wavelength 1578.27
•1578.69
Wavelength 1578.69
•1579.10
Wavelength 1579.10
•1579.52
Wavelength 1579.52
•1579.93
Wavelength 1579.93
•1580.35
Wavelength 1580.35
•1580.77
Wavelength 1580.77
•1581.18
Wavelength 1581.18
•1581.60
Wavelength 1581.60
•1582.02
Wavelength 1582.02
•1582.44
Wavelength 1582.44
•1582.85
Wavelength 1582.85
•1583.27
Wavelength 1583.27
•1583.69
Wavelength 1583.69
•1584.11
Wavelength 1584.11
•1584.53
Wavelength 1584.53
•1584.95
Wavelength 1584.95
•1585.36
Wavelength 1585.36
•1585.78
Wavelength 1585.78
•1586.20
Wavelength 1586.20
•1586.62
Wavelength 1586.62
•1587.04
Wavelength 1587.04
•1587.46
Wavelength 1587.46
•1587.88
Wavelength 1587.88
•1588.30
Wavelength 1588.30
•1588.73
Wavelength 1588.73
•1589.15
Wavelength 1589.15
•1589.57
Wavelength 1589.57
•1589.99
Wavelength 1589.99
•1590
Wavelength 1590
•1590.41
Wavelength 1590.41
•1590.83
Wavelength 1590.83
•1591.26
Wavelength 1591.26
•1591.68
Wavelength 1591.68
•1592.10
Wavelength 1592.10
•1592.52
Wavelength 1592.52
•1592.95
Wavelength 1592.95
•1593.37
Wavelength 1593.37
•1593.79
Wavelength 1593.79
•1594.22
Wavelength 1594.22
•1594.64
Wavelength 1594.64
•1595.06
Wavelength 1595.06
•1595.49
Wavelength 1595.49
•1596.34
Wavelength 1596.34
•1596.76
Wavelength 1596.76
•1597.19
Wavelength 1597.19
•1597.62
Wavelength 1597.62
•1598.04
Wavelength 1598.04
•1598.47
Wavelength 1598.47
•1598.89
Wavelength 1598.89
•1599.32
Wavelength 1599.32
•1599.75
Wavelength 1599.75
•1600.06
Wavelength 1600.06
•1601.03
Wavelength 1601.03
•1601.46
Wavelength 1601.46
•1601.88
Wavelength 1601.88
•1602.31
Wavelength 1602.31
•1602.74
Wavelength 1602.74
•1603.17
Wavelength 1603.17
•1603.60
Wavelength 1603.60
•1604.03
Wavelength 1604.03
•1610
Wavelength 1610
•USE-TWL1
Use Tunable Wavelength 1
<VOAATTN>
The value of calibrated attenuation for the variable optical attenuator (VOA). It is expressed in dBm. For the following cards, the range is 0.0 to +30.0: optical service channel, optical amplifier, dispersion compensation units, multiplexer, demultiplexer, and OADM. Not supported for TXP or MXP cards. VOAATIN is a float.
<VOAPWR>
The value of calibrated output power that the VOA is going to set as a result of its attenuation. Applicable only to the following cards: optical service channel, optical amplifier, dispersion compensation units, multiplexer, demultiplexer, and OADM. VOAPWR is a float.
<CALOPWR>
The value of the calibrated optical power expected for the line added to the calculated value, which equals the total expected output power. Expressed in dBm. Applicable only to the following cards: optical service channel, optical amplifier, dispersion compensation units, multiplexer, demultiplexer, and OADM. Defaults to 0 dBm. CALOPWR is a float.
<CHPOWER>
The value of per-channel optical power expected to the OCH drop port of an AD-4C unit. CHPOWER is a float expressed in dBm. The parameter type is REVERTIVE_TIME (revertive time).
•0.5 to 12.0
Revertive time is 0.5 to 12.0 minutes.
<PORTNAME>
Port name. PORTNAME is a string.
<SFBER>
Signal failure threshold for the SONET payload. Can only be provisioned on the working port. The parameter type is SF_BER, which is the threshold for declaring signal failure on a facility or path.
•1E-3
SFBER is 1E-3.
•1E-4
SFBER is 1E-4.
•1E-5
SFBER is 1E-5.
<SDBER>
Signal degrade threshold for the SONET payload. Can only be provisioned on the working port. The parameter type is SD_BER, which is the threshold for declaring signal degrade on a facility or path.
•1E-5
SDBER is 1E-5.
•1E-6
SDBER is 1E-6.
•1E-7
SDBER is 1E-7.
•1E-8
SDBER is 1E-8.
•1E-9
SDBER is 1E-9.
<COMM>
The generic communications channel (GCC) or data communications channel (DCC) is enabled or disabled. The GCC can be enabled only if the digital wrapper has been enabled for the card. The default is NONE.
On an MXP_2.5G_10G or TXP_MR_10G client port, only the DCC can be provisioned, if the termination mode is not transparent and the payload is SONET. On an MXP_2.5G_10G or TXP_MR_10G DWDM port, the DCC can be enabled only if the ITU-T G.709 is not enabled, if the payload is SONET, and the termination mode is not transparent. On an MXP_2.5G_10G or TXP_MR_10G DWDM port, the GCC can be enabled if there is no DCC and the ITU-T G.709 flag is enabled. On a TXP/MXP DWDM port, the DCC/GCC can be disabled only if no provisionable patchcord terminations are provisioned on the trunk port.
The parameter type is COMM_TYPE, which is the out of band communications channel termination type.
•DCC
Section DCC type.
•GCC
Generic communication channel (OTN) type.
•NONE
Disable DCC or GCC if enabled.
<GCCRATE>
The data rate of the GCC traffic. The default is 192 Kbps. For MXP_2.5G_10G and TXP_MR_10G cards, this applies only to the DWDM port.
Note The 576 kbps option is not supported for this release.
Parameter type is GCCRATE, which is the data rate of the GCC traffic.
•192K
192 kbps
•576K
576 kbps
<OSDBER>
OTN SDBER. Can only be provisioned on the working port. Defaults to 1E-7
Parameter type is SD_BER—the threshold for declaring signal degrade on a facility or path
•1E-5
SDBER is 1E-5
•1E-6
SDBER is 1E-6
•1E-7
SDBER is 1E-7
•1E-8
SDBER is 1E-8
•1E-9
SDBER is 1E-9
<DWRAP>
The ITU-T G.709 digital wrapper. It is either on or off. The system default is ON. For MXP_2.5G_10G and TXP_MR_10G cards, this applies only to the DWDM port.
To enable ITU-T G.709:
•There should be no GCC on the DWDM port.
•The payload (where the card is configured) should not be UNFRAMED.
To disable ITU-T G.709:
•There should be no GCC on the DWDM port.
•The forward error correction (FEC) should be turned to off.
•There should be no overhead circuit created on the DWDM port.
•(MXP only) None of the client ports on the card should be part of a Y-cable protection group.
The parameter type is ON_OFF, which disables or enables an attribute.
•N
Disable an attribute.
•Y
Enable an attribute.
<FEC>
Forward error correction. It can be enabled only if the ITU-T G.709 is turned ON. It is either off or enabled in standard or enhanced mode. The system default is standard FE enabled. The FEC level performance monitoring (PM) and thresholds apply if the FEC is turned ON. The parameter type is FEC_MODE, which specifies the type of forward error correction.
•ENH
Enhanced FEC is enabled.
•OFF
FEC is disabled.
•STD
Standard FEC is enabled.
<PAYLOADMAP>
The type of payload mapping. It can be enabled only if the ITU-T G.709 is turned ON and FEC is enabled. The parameter type is PAYLOAD_MAPPING (payload mapping mode).
•ASYNCH
Asynchronous mapping mode
•ODU
ODU multiplex structure mode
•SYNCH
Synchronous mapping mode
<MACADDR>
MAC address for the 10GigE payload. MACADDR is a string.
<SYNCMSG>
The facility be enabled to provide the synchronization clock. This does not apply to the TXPD-10G card. This applies to an MXPD-10G card, only if the payload is SONET/SDH and the card termination mode is as follows:
•TRANSPARENT: All client ports are available for all timing selections. All trunk ports are not available.
•LINE: All ports are available for all-timing selections.
The parameter type is ON_OFF, which disables or enables an attribute.
•N
Disable an attribute.
•Y
Enable an attribute.
<SENDDUS>
The facility sends out a Do not Use for Sync message. This does not apply to the TXPD-10G card. This applies to an MXPD-10G card only if the payload is SONET/SDH and the card termination mode is as follows:
•TRANSPARENT: All client ports are available for all timing selections. All Trunk ports are not available.
•LINE: All ports are available for all-timing selections.
The parameter type is ON_OFF, which disables or enables an attribute.
•N
Disable an attribute.
•Y
Enable an attribute.
<SOAK>
OOS-AINS to IS transition soak time as measured in 15-minute intervals. A value of 4 equals a soak time of 1 hour. The allowable range is 0 to 192 intervals (maximum of 48 hours). SOAK is an integer.
<OSPF>
Open Shortest Path First. The parameter type is EXT_RING, which indicates if the ring supports the extended K1/K2/K3 protocol.
•N
The ring does not support the extended K1/K2/K3 protocol.
•Y
The ring does support the extended K1/K2/K3 protocol.
<MFS>
Integer
<CMDMDE>
Command mode. The parameter type is CMDMDE, which forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied.
•FRCD
Force the system to override a state where the command would normally be denied.
•NORM
Execute the command normally. Do not override any conditions that might make the command fail.
<PST>
Primary state. The parameter type is PST, which indicates the current overall service condition of an entity.
•IS
In service
•OOS
Out of service
<SST>
Secondary state. The parameter type is SST, which provides additional information pertaining to PST and PSTQ.
•AINS
Automatic in service
•DSBLD
Disabled
•LPBK
Loopback
•MEA
Mismatch of equipment and attributes
•MT
Maintenance mode
•OOG
Out of group
•SWDL
Software downloading
•UAS
Unassigned
•UEQ
Unequipped
11.32 ED-OCHCC
(Cisco ONS 15454) The Edit Optical Channel Client Connection (ED-OCHCC) command edits the OCH client connection.
Usage Guidelines
•The fields after CTAG (trailing colons) are optional.
•This command does not support multiple editing of OCH client connection provisioning.
•The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. In order to obtain the current value, issue the RTRV-XX command.
CategoryDWDM
SecurityProvisioning
Input FormatED-OCHCC:[<TID>]:<AID>:<CTAG>[:::CKTID=<CKTID>],
[CMDMDE=<CMDMDE>]:[<PST>[,<SST>]];Input ExampleED-OCHCC:VA454-22:FAC-2-1-1:116:::CKTID=OCHCC,CMDMDE=FRCD:OOS,DSBLD;
Input Parameters
<AID>
Access identifier from the "FACILITY" section.
<CKTID>
Cross-connect ID. The default is Blank or None. String of ASCII characters. Maximum length is 48. If CKTID is empty or null the CKTID field will not be displayed.
<CMDMDE>
The parameter type is command mode, which forces the system to execute a given command regardless of any standing conditions. NORM mode is the default behavior for all commands but you can specify FRCD to force the system to override a state in which the command would normally be denied.
•FRCD
Force the system to override a state in which the command would normally be denied.
•NORM
Execute the command normally. Do not override any conditions that may make the command fail.
<PST>
Primary state. The parameter type is PST, which indicates the current overall service condition of an entity. The default is IS.
•IS
In service
•OOS
Out of service
<SST>
Secondary state. The parameter type is SST, which provides additional information pertaining to PST and PSTQ. The default is AINS.
•AINS
Automatic in-service
•DSBLD
Disabled
•LPBK
Loopback
•MEA
Mismatch of equipment and attributes
•MT
Maintenance mode
•OOG
Out of group
•SWDL
Software downloading
•UAS
Unassigned
•UEQ
Unequipped
11.33 ED-OCHNC
(Cisco ONS 15454) The Edit Optical Channel Network Connection (ED-OCHNC) command edits the OCH network connection.
Usage Guidelines
•The fields after CTAG (trailing colons) are optional.
•This command does not support multiple editing of wavelength connection provisioning.
•The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. In order to obtain the current value, issue the RTRV-XX command.
CategoryDWDM
SecurityProvisioning
Input FormatED-OCHNC:[<TID>]:<SRC>,<DST>:<CTAG>:::[CKTID=<CKTID>],
[CMDMDE=<CMDMDE>]:[<PST>[,<SST>]];Input ExampleED-OCHNC:VA454-22:CHANWL-1-3-TX-1530.33,
LINEWL-4-1-RX-1530.33:116:::CKTID=CIRCUIT,CMDMDE=FRCD:OOS,DSBLD;Input Parameters
<SRC>
Source access identifier from the "CHANNEL" section. In 2-way wavelength connection sources both directions need to be indicated.
<DST>
Destination access identifier from the "LINEWL" section. In 2-way wavelength connection sources both directions need to be indicated.
<CKTID>
Cross-connect ID. The default is Blank or None. String of ASCII characters. Maximum length is 48. If CKTID is empty or null the CKTID field will not be displayed.
<CMDMDE>
The parameter type is command mode, which forces the system to execute a given command regardless of any standing conditions. NORM mode is the default behavior for all commands but you can specify FRCD to force the system to override a state in which the command would normally be denied.
•FRCD
Force the system to override a state in which the command would normally be denied.
•NORM
Execute the command normally. Do not override any conditions that may make the command fail.
<PST>
Primary state. The parameter type is PST, which indicates the current overall service condition of an entity. The default is IS.
•IS
In service
•OOS
Out of service
<SST>
Secondary state. The parameter type is SST, which provides additional information pertaining to PST and PSTQ. The default is AINS.
•AINS
Automatic in-service
•DSBLD
Disabled
•LPBK
Loopback
•MEA
Mismatch of equipment and attributes
•MT
Maintenance mode
•OOG
Out of group
•SWDL
Software downloading
•UAS
Unassigned
•UEQ
Unequipped
11.34 ED-OMS
(Cisco ONS 15454) The Edit Optical Multiplex Section (ED-OMS) command edits the attributes (service parameters) and state of an OMS facility.
Usage Guidelines
None
CategoryDWDM
SecurityProvisioning
Input FormatED-OMS:[<TID>]:<AID>:<CTAG>:::[RDIRN=<RDIRN>],[EXPBAND=<EXPBAND>],
[VOAATTN=<VOAATTN>],[VOAPWR=<VOAPWR>],[CALOPWR=<CALOPWR>],
[CHPOWER=<CHPOWER>],[NAME=<NAME>],[SOAK=<SOAK>],
[CMDMDE=<CMDMDE>]:[<PST>[,<SST>]];Input ExampleED-OMS:PENNGROVE:BAND-6-1:114:::RDIRN=W-E,EXPBAND=1530.32-1532.68,
VOAATTN=2.5,VOAPWR=7.5,CALOPWR=0.0,CHPOWER=2.0,NAME="OMS PORT",
SOAK=8,CMDMDE=CMDMDE:IS,AINS;Input Parameters
<AID>
Access identifier from the "BAND" section.
<RDIRN>
Ring directionality of the optical line. The parameter type is RDIRN_MODE, which is the optical ring directionality.
•E-W
The direction of the signal is from east to west (clockwise).
•W-E
The direction of the signal is from west to east (counterclockwise).
<EXPBAND>
The expected value of the optical band for this port. The parameter type is OPTICAL_BAND (optical band).
•1530.33 to 1532.68
Band 1
•1534.25 to 1536.61
Band 2
•1538.19 to 1540.56
Band 3
•1542.14 to 1544.53
Band 4
•1546.12 to 1548.51
Band 5
•1550.12 to 1552.52
Band 6
•1554.13 to 1556.55
Band 7
•1558.17 to 1560.61
Band 8
•USE-DEFAULT
This band is not yet configured/retrieved from unit.
<VOAATTN>
The value of calibrated attenuation for the VOA expressed in dBm. The range is 0.0 to +30.0. VOAATTN is a float.
<VOAPWR>
The value of calibrated output power that the VOA is going to set as a result of its attenuation. VOAPWR is a float.
<CALOPWR>
The value of the calibrated optical power expected for the line added to the calculated value which equals the total expected output power. Expressed in dBm. Defaults to 0 dBm. CALOPWR is a float.
<CHPOWER>
The value of per-channel optical power. Float expressed in dBm. The parameter type is REVERTIVE_TIME (revertive time)
•0.5 to 12.0
Revertive time is 0.5 to 12.0 minutes.
<NAME>
Port name. NAME is a string.
<SOAK>
SOAK is an integer. Defaults to 8.
<CMDMDE>
Command mode. The parameter type is CMDMDE, which forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied.
•FRCD
Force the system to override a state where the command would normally be denied.
•NORM
Execute the command normally. Do not override any conditions that might make the command fail.
<PST>
Primary state. The parameter type is PST, which indicates the current overall service condition of an entity.
•IS
In service
•OOS
Out of service
<SST>
Secondary state. The parameter type is SST, which provides additional information pertaining to PST and PSTQ.
•AINS
Automatic in-service
•DSBLD
Disabled
•LPBK
Loopback
•MEA
Mismatch of equipment and attributes
•MT
Maintenance mode
•OOG
Out of group
•SWDL
Software downloading
•UAS
Unassigned
•UEQ
Unequipped
11.35 ED-OSC
(Cisco ONS 15454) The Edit Optical Service Channel (ED-OSC) command edits the optical service channel (OSC) group attributes.
Usage Guidelines
None
CategoryDWDM
SecurityProvisioning
Input FormatED-OSC:[<TID>]:<AID>:<CTAG>:::[RINGID=<RINGID>],[NODEID=<NODEID>];
Input ExampleED-OSC:PENNGROVE:OSC-1:114:::RINGID=1,NODEID=10;
Input Parameters
<AID>
Access identifier from the "OSC" section.
<RINGID>
The OSC ring ID of the NE, up to six characters. Valid characters are A-Z and 0-9. String. Default value is "# of AID OSC-#". RINGID is an integer.
<NODEID>
The OSC node ID of the NE. NODEID ranges from 0 to 31. NODEID is an integer.
11.36 ED-OTS
(Cisco ONS 15454) The Edit Optical Transport Section (ED-OTS) command edits the attributes (service parameters) and state of an OTS facility.
Usage Guidelines
None
CategoryDWDM
SecurityProvisioning
Input FormatED-OTS:[<TID>]:<AID>:<CTAG>:::[RDIRN=<RDIRN>],[VOAATTN=<VOAATTN>],
[VOAPWR=<VOAPWR>],[OFFSET=<OFFSET>],[CALTILT=<CALTILT>],[OSRI=<OSRI>],
[AMPLMODE=<AMPLMODE>],[CHPOWER=<CHPOWER>],[EXPGAIN=<EXPGAIN>],
[NAME=<NAME>],[SOAK=<SOAK>],[CMDMDE=<CMDMDE>]:<PST>,[<SST>];Input ExampleED-OTS:PENNGROVE:LINE-6-1:114:::RDIRN=W-E,VOAATTN=5.0,VOAPWR=10.0,OFFSET=0.0,CALTILT=0.0,OSRI=N,AMPLMODE=GAIN,CHPOWER=10.0,EXPGAIN=-5.0,
NAME="OTS PORT",SOAK=8,CMDMDE=CMDMDE:IS,AINS;Input Parameters
<AID>
Access identifier from the "LINE" section.
<RDIRN>
Ring directionality of the optical line. The parameter type is RDIRN_MODE, which is the optical ring directionality.
•E-W
The direction of the signal is from east to west (clockwise).
•W-E
The direction of the signal is from west to east (counterclockwise).
<VOAATTN>
The value of calibrated attenuation for the VOA expressed in dBm. The range is 0.0 to +30.0. VOAATTN is a float.
<VOAPWR>
The value of calibrated output power that the VOA is going to set as a result of its attenuation. VOAPWR is a float.
<OFFSET>
The calibration value of the optical power added to the calculated reference value. Defaults to 0 dBm. OFFSET is a float.
<CALTILT>
(Optional) The amplifier calibration tilt offset to be added to the calculated reference value. Defaults to 0 dBm. CALTILT is a float.
<OSRI>
(Optional) Optical safety remote interlock (OSRI) is enabled or disabled. Present only on a port where the OSRI is supported. The parameter type is ON_OFF, which disables or enables an attribute.
•N
Disable an attribute.
•Y
Enable an attribute.
<AMPLMODE>
The optical amplification control mode. The parameter type is AMPL_MODE, which defines the amplifier control mode.
•GAIN
The amplifier always maintains a fixed gain.
•POWER
The amplifier maintains the output power to a fixed value.
<CHPOWER>
The per-channel optical power. CHPOWER is a float.
<EXPGAIN>
The gain expected value to be reached from an amplifier when the node is part of a DWDM access network. EXPGAIN is a float.
<NAME>
The name of the port. NAME is a string.
<SOAK>
SOAK is an integer. It defaults to 8.
<CMDMDE>
Command mode. The parameter type is CMDMDE, which forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied.
•FRCD
Force the system to override a state where the command would normally be denied.
•NORM
Execute the command normally. Do not override any conditions that might make the command fail.
<PST>
Primary state. The parameter type is PST, which indicates the current overall service condition of an entity.
•IS
In service
•OOS
Out of service
<SST>
Secondary state. The parameter type is SST, which provides additional information pertaining to PST and PSTQ.
•AINS
Automatic in-service
•DSBLD
Disabled
•LPBK
Loopback
•MEA
Mismatch of equipment and attributes
•MT
Maintenance mode
•OOG
Out of group
•SWDL
Software downloading
•UAS
Unassigned
•UEQ
Unequipped
11.37 ED-PID
(Cisco ONS 15454, ONS 15327, ONS 15310-CL, ONS 15310-MA, ONS 15600) The Edit Password (ED-PID) command allows a user to change his or her own password.
Usage Guidelines
•Passwords are masked for the following security commands: ACT-USER, ED-PID, ENT-USER-SECU, and ED-USER-SECU. Access to a TL1 session by any means will have the password masked. The Cisco Transport Controller (CTC) Request History and Message Log will also show the masked commands. When a password-masked command is reissued by double-clicking the command from CTC Request History, the password will still be masked in the CTC Request History and Message Log. The actual password that was previously issued will be sent to the NE. To use a former command as a template only, single-click the command in CTC Request History. The command will be placed in the Command Request text box, where you can edit the appropriate fields prior to reissuing it.
•The password will not appear in the TL1 log on the NE.
•For the ED-PID command:
ED-PID:[TID]:<UID>:[CTAG]::<OLDPID>,<NEWPID>;
The syntax of OLDPID is not checked. The NEWPID is required to follow Telcordia standards (for example, 10 characters maximum including 1 letter, 1 number, and any one of the following characters: #, %, or +). The OLDPID must match what is in the database.
You must use the ED-USER-SECU command to change the default password for the CISCO15 superuser.
•The ED-PID command cannot be used to change the empty password to a valid password.
CategorySecurity
SecurityRetrieve
Input FormatED-PID:[<TID>]:<UID>:<CTAG>::<OLDPID>,<NEWPID>;
Input ExampleED-PID:CISCO:UID:123::OLDPWD,NEWPWD;
Input Parameters
11.38 ED-POS
(Cisco ONS 15454, ONS 15310-CL, ONS 15310-MA, ONS 15600) The Edit Packet-Over-SONET (ED-POS) command edits the back-end port information for the Ethernet card when the back-end port is working in POS mode. The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. In order to obtain the current value, issue the RTRV-XX command to retrieve them. ED-POS cannot set ENCAP and PST/SST.
Usage Guidelines
This command is supported for the ONS 15454 CE-100T-8 and CE-1000-4 cards, the ONS 15310-CL ML-100T-8 and CE-100T-8 cards, and the ONS 15600 ASAP card.
CategoryPorts
SecurityProvisioning
Input FormatED-POS:[<TID>]:<AID>:<CTAG>:::[ENCAP=<ENCAP>],[NAME=<NAME>],
[CMDMDE=<CMDMDE>],[SOAK=<SOAK>]:[<PST>[,<SST>]];Input ExampleED-POS:CISCO:VFAC-2-0:123:::ENCAP=HDLC,NAME=NAME,CMDMDE=CMDMDE,
SOAK=32:IS,AINS;Input Parameters
<AID>
Access identifier from the "FACILITY" section.
<ENCAP>
Encapsulation. The parameter type is ENCAP, which is the frame encapsulation type.
•GFP_F
GFP frame mode
•GFP_T
GFP transparent mode
•HDLC
HDLC frame mode
•HDLC_LEX
HDLC LAN extension frame mode
•HDLC_X86
HDLC X.86 frame mode
<NAME>
Port name. NAME is a string.
<CMDMDE>
Command Mode. The FRCD mode of operation is applicable to delete a VCAT member cross-connect from IS-NR or OOS-AU,AINS service state. The parameter type is CMDMDE, which forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied.
•FRCD
Force the system to override a state where the command would normally be denied.
•NORM
Execute the command normally. Do not override any conditions that might make the command fail.
<SOAK>
OOS-AINS to IS transition soak time as measured in 15 minute intervals, so a value of 4 translates to a soak time of 1 hour. The allowable range is 0 to 192 intervals (maximum of 48 hours). SOAK is an integer.
<PST>
Primary state. The parameter type is PST, which indicates the current overall service condition of an entity.
•IS
In service
•OOS
Out of service
<SST>
Secondary state. The parameter type is SST, which provides additional information pertaining to PST and PSTQ.
•AINS
Automatic in-service
•DSBLD
Disabled
•LPBK
Loopback
•MEA
Mismatch of equipment and attributes
•MT
Maintenance mode
•OOG
Out of group
•SWDL
Software downloading
•UAS
Unassigned
•UEQ
Unequipped
11.39 ED-PROTOCOL
(Cisco ONS 15454, ONS 15327, ONS 15310-CL, ONS 15310-MA, ONS 15600) The Edit Protocol (ED-PROTOCOL) command is used to enable/disable a protocol/service that is supported in the NE. Valid protocols include shell/file system access (SHELL), EMS, TL1, and Simple Network Management Protocol (SNMP).
Usage Guidelines
•If the AID is TL1, the command will be denied because TL1 users are not allowed to change the setting for TL1 protocol.
•If the AID is SNMP, the SECURE PROTOCOLSTAT is not supported. SNMP can only be enabled or disabled. To enable SNMP, set PROTOCOLSTAT to UNSECURE.
CategorySecurity
SecuritySuperuser
Input FormatED-PROTOCOL:[<TID>]:<PROTOCOLAID>:<CTAG>::<PROTOCOLSTAT>;
Input ExampleED-PROTOCOL:CISCONODE:EMS:123::SECURE;
Input Parameters
11.40 ED-ROLL-<MOD_PATH>
(Cisco ONS 15454, ONS 15327, ONS 15310-CL, ONS 15310-MA, ONS 15600) The Edit Roll for STS1, STS12C, STS192C, STS24C, STS3C, STS48C, STS6C, STS9C, VT1, or VT2 (ED-ROLL-<MOD_PATH>) command forces a rolling operation. Force attempts to force a valid signal to complete the rolling operation.
Usage Guidelines
See Table 27-1 for supported modifiers by platform.
Note STS18C and STS36C are not supported for this command in this release.
CategoryBridge and Roll
SecurityProvisioning
Input FormatED-ROLL-<MOD_PATH>:[<TID>]:<FROM>,<TO>:<CTAG>:::[CMDMDE=<CMDMDE>];
Input ExampleED-ROLL-STS1:CISCO:STS-1-1-1,STS-2-1-1:1:::CMDMDE=FRCD;
Input Parameters
<FROM>
Source access identifier from the "CrossConnectId1" section. It is one of the termination points (legs) of the existing cross-connection. If the existing cross-connection is one-way, then this termination point (leg) should be the FROM-AID termination point. Otherwise, FROM is not significant. FROM and TO should be entered as they are entered in the ENT-CRS command. You can issue RTRV-CRS command, and use the response for FROM and TO parameters.
<TO>
Destination access identifier from the "CrossConnectId1" section. It is one of the termination points (legs) of the existing cross-connection. If the existing cross-connection is one-way, then this termination point (leg) should be the TO-AID termination point. Otherwise, the TO is not significant. FROM and TO should be entered as they are entered in the ENT-CRS command. You can issue RTRV-CRS command, and use the response for FROM and TO parameters.
<CMDMDE>
Command execution mode. Defaults to NORM.
Note CMDMDE can only go from NORM to FRCD (cannot go from FRCD to NORM). CMDMDE cannot be set to NORM using this command.
The parameter type is CMDMDE, which forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied.
•FRCD
Force the system to override a state where the command would normally be denied.
•NORM
Execute the command normally. Do not override any conditions that might make the command fail.
11.41 ED-SLV-WDMANS
(Cisco ONS 15454) The Edit Span Loss Verification Wavelength Division Multiplexing Automatic Node Set-Up (ED-SLV-WMANS) command edits the expected span loss verification.
Usage Guidelines
None
CategoryDWDM
SecurityMaintenance
Input FormatED-SLV-WDMANS:[<TID>]:<AID>:<CTAG>:::[HIGHSLVEXP=<HIGHSLVEXP>],
[LOWSLVEXP=<LOWSLVEXP>];Input ExampleED-SLV-WDMANS:VA454-22:WDMANS-E:116:::HIGHSLVEXP=10.0,LOWSLVEXP=5.0;
Input Parameters
<AID>
Access identifier from the "WDMANS" section.
<HIGHSLVEXP>
The high range value of the expected span loss verification. HIGHSLVEXP is a float.
<LOWSLVEXP>
The low range value of the expected span loss verification. LOWSLVEXP is a float.
11.42 ED-SYNCN
(Cisco ONS 15454, ONS 15327, ONS 15310-CL, ONS 15310-MA, ONS 15600) The Edit Synchronization (ED-SYNCN) command edits the synchronization reference list used to determine the sources for the NE's reference clock and the BITS output clock. For each clock, up to three synchronization sources might be specified (for example, PRIMARY, SECOND, THIRD).To view or edit the system timing mode, use the RTRV-NE-SYNCN or ED-NE-SYNCN commands.
Usage Guidelines
To retrieve/set the timing mode, SSM message set, or quality of RES information, use the RTRV-NE-SYNCN and ED-NE-SYNCN commands.
CategorySynchronization
SecurityProvisioning
Input FormatED-SYNCN:[<TID>]:<AID>:<CTAG>:::[PRI=<PRI>],[SEC=<SEC>],[THIRD=<THIRD>][:];
Input ExampleED-SYNCN:BOYES:SYNC-NE:112:::PRI=INTERNAL,SEC=INTERNAL,THIRD=INTERNAL;
Input Parameters
<AID>
Access identifier from the "SYNC_REF" section.
<PRI>
Primary reference of the synchronization from the "SYN_SRC" section.
<SEC>
Secondary reference of the synchronization from the "SYN_SRC" section.
<THIRD>
Third reference of the synchronization from the "SYN_SRC" section.
11.43 ED-T1
(Cisco ONS 15454, ONS 15327, ONS 15310-CL, ONS 15310-MA) The Edit Digital Signal Facility (ED-T1) command edits the attributes related to a DS1/T1 port.
Usage Guidelines
•The T1 facilities on the ONS 15327 and ONS 15310-CL are on the XTC/15310-CL-CTX card.
•This command is not allowed if the card is a protect card.
•If sending this command to edit TACC and any other attribute(s), and the port having the cross-connection, the Parameters Not Compatible error message will be returned.
•Editing the TACC using an ED-xxx command is only allowed when there is no circuit/cross-connection on the port and the port/VT does not have a TAP or TACC number. Otherwise, an error message (for example, VT in Use) will be returned.
•TACC creation will be denied on protect ports/cards.
•AUTO-PROV is not supported.
•The AISONLPBK and RETIME options are applicable only to the ONS 15310-CL and the DS2/E1-56 card on the ONS 15454.
•The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. Use the RTRV-XX commands to retrieve the current values.
•The parameters SYNCMAP, ADMSSM, VTMAP, and INHFELPBK are only supported on the DS1/E1-56 card on the ONS 15454.
CategoryPorts
SecurityProvisioning
Input FormatED-T1:[<TID>]:<AID>:<CTAG>:::[LINECDE=<LINECDE>],[FMT=<FMT>],[LBO=<LBO>],
[TACC=<TACC>],[TAPTYPE=<TAPTYPE>],[SOAK=<SOAK>],[SFBER=<SFBER>],
[SDBER=<SDBER>],[SYNCMSG=<SYNCMSG>],[SENDDUS=<SENDDUS>],
[RETIME=<RETIME>],[NAME=<NAME>],[MODE=<MODE>],[SYNCMAP=<SYNCMAP>],
[ADMSSM=<ADMSSM>],[VTMAP=<VTMAP>],[INHFELPBK=<INHFELPBK>],
[AISONLPBK=<AISONLPBK>],[CMDMDE=<CMDMDE>],
[AISVONAIS=<AISVONAIS>]:[<PST>[,<SST>]];Input ExampleED-T1:CISCO:FAC-2-1:1223:::LINECDE=AMI,FMT=ESF,LBO=0-131,TACC=8,
TAPTYPE=SINGLE,SOAK=10,SFBER=1E-4,SDBER=1E-6,SYNCMSG=Y,SENDDUS=Y,
RETIME=Y,NAME="T1PORT",MODE=FDL,SYNCMAP=ASYNC,ADMSSM=STU,
VTMAP=GR253,INHFELPBK=N,AISONLPBK=AIS_ON_LPBK_ALL,CMDMDE=CMDMDE,
AISVONAIS=Y:IS,AINS;Input Parameters
<AID>
Access identifier from the "FACILITY" section.
<LINECDE>
Line code. The parameter type is LINE_CODE.
•AMI
Line code value is AMI.
•B8ZS
Line code value is B8ZS.
<FMT>
Digital signal frame format. The parameter type is FRAME_FORMAT, which is the frame format for a T1 port.
•D4
Frame format is D4.
•ESF
Frame format is ESF.
•UNFRAMED
Frame format is unframed.
<LBO>
Line build-out settings. The parameter type is LINE_BUILDOUT.
•0-131
Line build-out range is 0-131.
•132-262
Line build-out range is 132-262.
•263-393
Line build-out range is 263-393.
•394-524
Line build-out range is 394-524.
•525-655
Line build-out range is 525-655.
<TACC>
TAP number within a range of 0 to 999. Indicates whether the digroup being provisioned is to be used as a test access digroup. When TACC is 0 (zero), the TAP is deleted. Default is N. TACC is an integer.
<TAPTYPE>
TAP type. Defaults to DUAL. The parameter type is TAPTYPE (test access point type).
•DUAL
Dual FAD
•SINGLE
Single FAD
<SOAK>
OOS-AINS to IS transition soak time as measured in 15-minute intervals. A value of 4 equals a soak time of 1 hour. The allowable range is 0 to 192 intervals (maximum of 48 hours). SOAK is an integer.
<SFBER>
The port signal failure threshold. The parameter type is SF_BER, which is the threshold for declaring signal failure on a facility or path.
•1E-3
SFBER is 1E-3.
•1E-4
SFBER is 1E-4.
•1E-5
SFBER is 1E-5.
<SDBER>
Port signal degrade threshold. The parameter type is SD_BER, which is the threshold for declaring signal degrade on a facility or path.
•1E-5
SDBER is 1E-5.
•1E-6
SDBER is 1E-6.
•1E-7
SDBER is 1E-7.
•1E-8
SDBER is 1E-8.
•1E-9
SDBER is 1E-9.
<SYNCMSG>
Synchronization status messaging is enabled or disabled on the T1 facility.
Note For the ONS 15310-CL, SYNCMSG defaults to N. SYNCMSG is not supported on the ONS 15454 or ONS 15327.
The parameter type is YES_NO, which indicates whether the user's password is about to expire, the user is logged into the NE, or the user is locked out of the NE.
•NO
No
•YES
Yes
<SENDDUS>
The facility will send the DUS value as the SSM for that facility.
Note For the ONS 15310-CL, SENDDUS is optional and defaults to N. SENDDUS is not supported on the ONS 15454 or ONS 15327.
The parameter type is YES_NO, which indicates whether the user's password is about to expire, the user is logged into the NE, or the user is locked out of the NE.
•NO
No
•YES
Yes
<RETIME>
Indicates if retiming is needed.
Note For the ONS 15310-CL, RETIME is optional and defaults to N. RETIME is not supported on the ONS 15454 or ONS 15327.
The parameter type is YES_NO, which indicates whether the user's password is about to expire, the user is logged into the NE, or the user is locked out of the NE.
•NO
No
•YES
Yes
<NAME>
Name. NAME is a string.
<MODE>
Mode. Default value is FDL. The parameter type is DS1MODE, which is the DS1 path mode of the DS3XM-12 card.
•ATT
Indicates that the DS1 path of the DS3XM-12 is in AT&T 54016 mode.
•FDL
Indicates that the DS1 path of the DS3XM-12 is in FDL T1-403 mode.
<SYNCMAP>
The synchronous mapping for the DS1 facility. Defaults to ASYNC. Only supported on ONS 15454. The parameter type is SYNCMAP (synchronous mapping type).
•ASYNC
Asynchronous
•BYTE
Mapping in byte
•JBYTE
Mapping in jbyte
<ADMSSM>
The administrative synchronization status message. Only supported on the ONS 15454. Defaults to STU. The parameter type is SYNC_CLOCK_REF_QUALITY_LEVEL, which is the clock source quality level.
•DUS
Do Not Use For Synchronization
•PRS
Primary Reference Source, Stratum 1 Traceable
•RES
Reserved For Network Synchronization Use
•SMC
SONET Minimum Clock Traceable
•ST2
Stratum 2 Traceable
•ST3
Stratum 3 Traceable
•ST3E
Stratum 3E Traceable
•ST4
Stratum 4 Traceable
•STU
Synchronized, Traceability Unknown
•TNC
Transit Node Clock (2nd Generation Only)
<VTMAP>
The port to VT mapping type for that particular STS. Only supported on ONS 15454. Defaults to GR253. The parameter type is VTMAP (VT mapping).
•GR253
Mapping based on Telcordia GR-253.
•INDUSTRY
Mapping based on industry standard.
<INHFELPBK>
Indicates whether far-end loopbacks are inhibited on the facility. Only supported on the ONS 15454. Defaults to N. The parameter type is ON_OFF, which disables or enables an attribute.
•N
Disable an attribute.
•Y
Enable an attribute.
<AISONLPBK>
Defaults to AIS_ON_LPBK_ALL. The parameter type is AIS_ON_LPBK, which indicates if AIS is sent on a loopback.
•AIS_ONLPBK_FACILITY
AIS is sent on facility loopbacks.
•AIS_ON_LPBK_ALL
AIS is sent on all loopbacks.
•AIS_ON_LPBK_OFF
AIS is not sent on loopbacks.
•AIS_ON_LPBK_TERMINAL
AIS is sent on terminal loopbacks.
<CMDMDE>
Command mode. The parameter type is CMDMDE, which forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied.
•FRCD
Force the system to override a state where the command would normally be denied.
•NORM
Execute the command normally. Do not override any conditions that might make the command fail.
<AISVONAIS>
Defaults to N. The parameter type is ON_OFF, which disables or enables an attribute.
•N
Disable an attribute.
•Y
Enable an attribute.
<PST>
Primary state. The parameter type is PST, which indicates the current overall service condition of an entity.
•IS
In service
•OOS
Out of service
<SST>
Secondary state. The parameter type is SST, which provides additional information pertaining to PST and PSTQ.
•AINS
Automatic in-service
•DSBLD
Disabled
•LPBK
Loopback
•MEA
Mismatch of equipment and attributes
•MT
Maintenance mode
•OOG
Out of group
•SWDL
Software downloading
•UAS
Unassigned
•UEQ
Unequipped
11.44 ED-T3
(Cisco ONS 15454, ONS 15327, ONS 15310-CL, ONS 15310-MA) The Edit Digital Signal Facility (ED-T3) command edits the attributes related to a DS3/T3 port and the DS3i-N-12 card.
Usage Guidelines
•The T3 facilities on the ONS 15327 and ONS 15310-CL are on the XTC/15310-CL-CTX card.
•This command is not allowed if the card is a protect card.
•Neither FMT nor Line code are supported for T3/DS3 facility. They are supported on both the DS3XM and DS3E card. The unframed value of the framing format is only supported on the DS3E facility.
•If you send this command to edit TACC and any other attribute(s), and the port having the cross-connection or the port/VT has a TAP or TACC number, the Parameters Not Compatible error message is returned.
•Editing TACC using an ED-xxx command is only allowed when there is no circuit/cross-connection on the port and the port/VT does not have a TAP or TACC number. Otherwise, an error message (VT in Use) will be returned.
•TACC creation will be denied on the protect ports/cards.
•Automatic application of loopbacks originating from the far end can be initiated on the T3 ports of a DS3E, DS3NE, or DS3XM card.
•CTC can set the FMT attribute of a DS3(N)E line to AUTOPROVISION to set the framing based on the framing that is coming in. The result is the FMT field being blanked out for a few seconds or blanked out indefinitely for a preprovisioned DS3(N)E card in CTC. AUTOPROVISION is not considered a valid DS3 framing type. It is only used to trigger an autosense and subsequent autoprovisioning of a valid DS3 framing type (unframed, M13, C-BIT). TL1 does not have the AUTOPROVISION mode. TL1 maps/returns the AUTOPROVISION mode to the unframed framing type.
•For the DS3XM-12 card, the DS3/T3 configurable attributes (PM, TH, alarm, etc.) only apply on the ported ports (1 to 12) and the DS3-mapped (even) portless ports in xxx-xxx-T3 commands. If you attempt to provision or retrieve DS3/T3 attributes on the VT-mapped (odd) portless port in xxx-xxx-T3 commands, an error message is returned.
•For the DS3XM-12 card, if the administrative state is already set for a portless port, the state setting operation over its associated ported port is an invalid operation.
•The test set physical connection set up through ED-T3/DS1/STS1/VT1 of the DS3XM-12 card is only allowed on the physical front ports (PORTED ports, Ports 1 to 12), which are the monitoring ports.
–The monitoring test access ports follow the common rules for the other cards. For example, ED-T3 on Port 2 (FAC-6-2) with a TACC number (8), the next port, Port 3 (FAC-6-3) is used as the monitoring point also. The RTRV-T3 on both Port 2 and Port 3 return the same TACC number (8) being used to monitor the cross-connection end (A-B). The last port (Port 12) is not allowed to set up a physical connection with the test set because there is no next available port to be the monitoring port.
–The DISC-TACC and CHG-TACC commands follow the same requirements as in the previous bullet, but applied on the ported ports of the DS3XM-12 card.
–The CONN-TACC command has monitored points that can be portless ports. This command is applied on both ported and portless ports of the DS3XM-12 card.
•If the entity has a TACC connection, the entity is not allowed to have ported or portless STS/VT cross-connection (or circuit) provisioning on the DS3XM-12 card.
•ED-T3 cannot be used to create TAPs on the DS3i-N-12 card on the SONET platform because the DS3I card only supports STS3C TAPs.
•You cannot use this command to change the default provisioning on Slots 3 and 15 for the DS3/EC1-48 card.
•The AISONLPBK parameter is only applicable to the ONS 15310-CL.
•The default values for all optional parameters are NE default values. These values might not be the current value for a parameter. Use the RTRV-XX command to retrieve current default values.
CategoryPorts
SecurityProvisioning
Input FormatED-T3:[<TID>]:<AID>:<CTAG>:::[FMT=<FMT>],[LINECDE=<LINECDE>],[LBO=<LBO>],
[INHFELPBK=<INHFELPBK>],[TACC=<TACC>],[TAPTYPE=<TAPTYPE>],[SOAK=<SOAK>],
[SFBER=<SFBER>],[SDBER=<SDBER>],[NAME=<NAME>],[AISONLPBK=<AISONLPBK>],
[CMDMDE=<CMDMDE>]:[<PST>[,<SST>]];Input ExampleED-T3:CISCO:FAC-1-2:123:::FMT=C-BIT,LINECDE=B3ZS,LBO=0-225,INHFELPBK=N,
TACC=8,TAPTYPE=SINGLE,SOAK=10,SFBER=1E-4,SDBER=1E-6,NAME="T3 PORT",
AISONLPBK=AIS_ON_LPBK_ALL,CMDMDE=CMDMDE:IS,AINS;Input Parameters
<AID>
Access identifier from the "FACILITY" section.
<FMT>
Digital signal frame format. The unframed value of the framing format is only supported for the DS3E card. The parameter type is DS_LINE_TYPE, which is the DS123 line type.
•C-BIT
C-BIT line type applies to the DS3XM and DS3E cards.
•M13
M13 line type applies to the DS3XM and DS3E cards.
•UNFRAMED
Line type is unframed. The old DS3 (L3M) and DS3CR cards can only run in unframed mode.
<LINECDE>
Line code. The parameter type is DS_LINE_CODE, which is the DS123 line code.
•B3ZS
Bipolar with three-zero substitution
<LBO>
Line build-out settings. LBO is an integer. The parameter type is E_LBO, which is the electrical signal line build-out.
•0-225
Electrical signal line build-out range is 1-225.
•226-450
Electrical signal line build-out range is 226-450.
<INHFELPBK>
(Optional) Far-end loopback inhibition attribute of the port. If it is Y, the automatic far-end loopbacks are inhibited. It is either on or off. The system default is N. The parameter type is ON_OFF, which disables or enables an attribute.
•N
Disable an attribute.
•Y
Enable an attribute.
<TACC>
TAP number within a range of 0 to 999. Indicates whether the digroup being provisioned is to be used as a test access digroup. When TACC is 0 (zero), the TAP is deleted. Default is N. TACC is an integer.
<TAPTYPE>
TAP type. Defaults to DUAL. The parameter type is TAPTYPE, which is the test access point type.
•DUAL
Dual FAD
•SINGLE
Single FAD
<SOAK>
OOS-AINS to IS transition soak time as measured in 15-minute intervals. A value of 4 equals a soak time of 1 hour. The allowable range is 0 to 192 intervals (maximum of 48 hours). SOAK is an integer.
<SFBER>
The port signal failure threshold. The parameter type is SF_BER, which is the threshold for declaring signal failure on a facility or path.
•1E-3
SFBER is 1E-3.
•1E-4
SFBER is 1E-4.
•1E-5
SFBER is 1E-5.
<SDBER>
Port signal degrade threshold. The parameter type is SD_BER, which is the threshold for declaring signal degrade on a facility or path.
•1E-5
SDBER is 1E-5.
•1E-6
SDBER is 1E-6.
•1E-7
SDBER is 1E-7.
•1E-8
SDBER is 1E-8.
•1E-9
SDBER is 1E-9.
<NAME>
Name. NAME is a string.
<AISONLPBK>
The parameter type is AIS_ON_LPBK, which indicates whether. AIS is sent on a loopback. Defaults to AIS_ON_LPBK_ALL.
•AIS_ONLPBK_FACILITY
AIS is sent on facility loopbacks.
•AIS_ON_LPBK_ALL
AIS is sent on all loopbacks.
•AIS_ON_LPBK_OFF
AIS is not sent on loopbacks.
•AIS_ON_LPBK_TERMINAL
AIS is sent on terminal loopbacks.
<CMDMDE>
Command mode. The parameter type is CMDMDE, which forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands but you can specify FRCD to force the system to override a state where the command would normally be denied.
•FRCD
Force the system to override a state where the command would normally be denied.
•NORM
Execute the command normally. Do not override any conditions that might make the command fail.
PST
Primary state. The parameter type is PST, which indicates the current overall service condition of an entity.
•IS
In service
•OOS
Out of service
SST
Secondary state. The parameter type is SST, which provides additional information pertaining to PST and PSTQ.
•AINS
Automatic in-service
•DSBLD
Disabled
•LPBK
Loopback
•MEA
Mismatch of equipment and attributes
•MT
Maintenance mode
•OOG
Out of group
•SWDL
Software downloading
•UAS
Unassigned
•UEQ
Unequipped
11.45 ED-TRAPTABLE
(Cisco ONS 15454, ONS 15327, ONS 15310-CL, ONS 15310-MA, ONS 15600) The Edit Trap Table (ED-TRAPTABLE) command edits a trap destination entry identified by a specific trap destination address.
Usage Guidelines
None
CategorySystem
SecurityProvisioning
Input FormatED-TRAPTABLE:[<TID>]:<AID>:<CTAG>:::COMMUNITY=<COMMUNITY>,
[TRAPPORT=<TRAPPORT>],[TRAPVER=<TRAPVER>];Input ExampleED-TRAPTABLE::1.2.3.4:1:::COMMUNITY="PUBLIC",TRAPPORT=162,TRAPVER=SNMPV1;
Input Parameters
<AID>
Access identifier from the "IPADDR" section. IP address identifying the trap destination.
<COMMUNITY>
Community name associated to the trap destination. Maximum of 32 characters. COMMUNITY is a string.
<TRAPPORT>
User datagram protocol (UDP) port number associated with the trap destination. Default to 162. TRAPPORT is an integer.
<TRAPVER>
SNMP version number. Defaults to SNMPv1. The parameter type is SNMP_VERSION (SNMP version).
•SNMPV1
SNMP version 1 (default)
•SNMPV2
SNMP version 2
11.46 ED-TRC-OCH
(Cisco ONS 15454) The Edit Trace Optical Channel Facility (ED-TRC-OCH) command edits trace-related optical channel facilities. Refer to the Cisco ONS SONET TL1 Reference Guide for specific card provisioning rules.
Usage Guidelines
None
CategoryDWDM
SecurityProvisioning
Input FormatED-TRC-OCH:[<TID>]:<SRC>:<CTAG>:::[EXPTRC=<EXPTRC>],[TRC=<TRC>],
[TRCMODE=<TRCMODE>],[TRCLEVEL=<TRCLEVEL>],[TRCFORMAT=<TRCFORMAT>][:];Input ExampleED-TRC-OCH:CISCO:CHAN-6-2:10:::EXPTRC="AAA",TRC="AAA",TRCMODE=MAN,
TRCLEVEL=TTI-PM,TRCFORMAT=64-BYTE;Input Parameters
<SRC>
Source access identifier from the "CHANNEL" section.
<EXPTRC>
Expected path trace content. Indicates the expected path trace message (J1) contents. EXPTRC is any 64-character ASCII string, including the terminating CR (carriage return) and LF (line feed). A null value is equivalent to ALL. EXPTRC is a string.
<TRC>
The path trace message to be transmitted. The trace byte continuously transmits a 64-byte, fixed-length, ASCII string, one byte at a time. A null value defaults to the NE transmitting 62 null characters (Hex 00) and CR and LF. A null value is equivalent to ALL.
<TRCMODE>
Trace mode. Defaults to the OFF mode. The parameter type is TRCMODE (trace mode).
•AUTO
Use the previously received path trace string as the expected string. Not applicable to MXP/TXP cards.
•AUTO-NO-AIS
Use the previously received path trace string as the expected string and do not turn on AIS and RDI if TIM-P is detected.
•MAN
Use the provisioned expected string as the expected string.
•MAN-NO-AIS
Use the provisioned expected string as the expected string and do not turn on AIS and RDI if TIM-P is detected.
•OFF
Turn off path trace capability. Nothing will be reported.
<TRCLEVEL>
The trace level to be managed. TRCLEVEL is a string.
<TRCFORMAT>
Trace message size. The parameter type is TRCFORMAT (trace format).
•1-BYTE
1 byte trace message
•16-BYTE
16 byte trace message
•64-BYTE
64 byte trace message
•Y
Enable an attribute
11.47 ED-USER-SECU
(Cisco ONS 15454, ONS 15327, ONS 15310-CL, ONS 15310-MA, ONS 15600) The Edit User Security (ED-USER-SECU) command edits a user's privileges, password, or ID. Only a Superuser can perform this operation. Privilege levels are described in the ENT-USER-SECU command.
Usage Guidelines
•Passwords are masked for the following security commands: ACT-USER, ED-PID, ENT-USER-SECU, and ED-USER-SECU. Access to a TL1 session by any means will have the password masked. The CTC Request History and Message Log will also show the masked commands. When a password-masked command is reissued by double-clicking the command from CTC Request History, the password will still be masked in the CTC Request History and Message Log. The actual password that was previously issued will be sent to the NE. To use a former command as a template only, single-click the command in CTC Request History. The command will be placed in the Command Request text box, where you can edit the appropriate fields prior to reissuing it.
•Although the CTC allows both a <UID> and a <PID> of up to 20 characters, the CTC-entered users (<UID>, <PID>) are not valid TL1 users. For example, if you issue an ACT-USER command using a CTC-entered <UID> that is greater than 10 characters long, TL1 will respond with DENY.
•For the ED-USER-SECU command:
ED-USER-SECU:[TID]:<UID>:[CTAG]::[<NEWUID>],[<NEWPID>],,[<UAP>]:;
–If the <NEWPID> is specified, the syntax is checked.
–The syntax of <UID> is not checked.
–Old users can change their password without changing their user ID, but the new password must meet the new requirements.
–The <NEWPID> is required when changing the <UID>.
•In this release, when <NEWUID> is specified, <NEWPID> (and the <UAP>) become mandatory, but it is possible to change a <UID> without changing the password by providing the same password. You cannot keep your old password if the old password does not meet the new syntax requirements. For example:
–<UID> = CISCO2345
<PID>=CISCO#234 /*PASSWORD ALREADY MEETS REQUIREMENTS*/ED-USER-SECU::CISCO2345:1::CISCO3456,CISCO#234,,PROV;
TCCP 1970-01-02 13:15:35 M 1 COMPLD ;
–<NEWUID> = CISCO60
<UID> = CISCO40 <PID>=CISCO40 /*PASSWORD DOES NOT MEET REQUIREMENTS*/ED-USER-SECU::CISCO40:1::CISCO60,CISCO40,,PROV;
BRONCOS4 1970-01-02 13:14:24 M 1 DENY IIFM /* INVALID PASSWORD */ ;
•The ED-USER-SECU command should be used to change the default password for the CISCO15 default Superuser.
•The ED-PID command cannot be used to change the empty password to a valid password.
CategorySecurity
SecuritySuperuser
Input FormatED-USER-SECU:[<TID>]:<UID>:<CTAG>::[<NEWUID>],[<NEWPID>],,[<UAP>][:];
Input ExampleED-USER-SECU:PETALUMA:CISCO15:123::NEWUID,NEWPID,,MAINT;
Input Parameters
11.48 ED-VCG
(Cisco ONS 15454, ONS 15310-CL, ONS 15310-MA) The Edit Virtual Concatenated Group (ED-VCG) command edits the attributes of a VCG.
Usage Guidelines
None
CategoryVCAT
SecurityProvisioning
Input FormatED-VCG:[<TID>]:<SRC>:<CTAG>:::[TXCOUNT=<TXCOUNT>],[NAME=<NAME>];
Input ExampleED-VCG:NODE1:FAC-1-1:1234:::TXCOUNT=7,NAME="VCG2";
Input Parameters
<SRC>
Source access identifier from the "FACILITY" section.
<TXCOUNT>
Number of members in the transmit (Tx) direction. For ML1000-2 and ML100T-12 cards, the only valid value is 2. For the FC_MR-4 card, the only valid value is 8. TXCOUNT is an integer.
<NAME>
Name of the VCAT group. Maximum length is 64 characters. NAME is a string.
11.49 ED-WDMANS
(Cisco ONS 15454) The Edit Wavelength Division Multiplexing Automatic Node Set Up (ED-WDMANS) command edits the optical node set-up application (AONS) attributes.
Usage Guidelines
None
CategoryDWDM
SecurityMaintenance
Input FormatED-WDMANS:[<TID>]:<AID>:<CTAG>:::[POWER-IN=<POWERIN>],
[POWER-OUT=<POWEROUT>],[POWER-EXP=<POWEREXP>],[NTWTYPE=<NTWTYPE>];Input ExampleED-WDMANS:PENNGROVE:WDMANS-W:114:::POWERIN=10.0,POWEROUT=10.0,|
POWEREXP=10.0,NTWTYPE=METRO-CORE;Input Parameters
<AID>
Access identifier from the "WDMANS" section.
<POWERIN>
Input power for the OADM section or Mux/Demux for terminal nodes. POWERIN is a float.
<POWEROUT>
Output power for the OADM section or Mux/Demux for terminal nodes. POWEROUT is a float.
<POWEREXP>
Express power for the OADM section. POWEREXP is a float.
<NTWTYPE>
Network type where a DWDM node is installed. The parameter type is DWDM_RING_TYPE, which is the network type where the NE is installed.
•METRO-ACCESS
The network where a DWDM node is installed is a metro access network.
•METRO-CORE
The network where a DWDM node is installed is a metro core network.
•NONE
The node does not have a standard DWDM configuration.
Posted: Thu Sep 13 02:34:39 PDT 2007
All contents are Copyright © 1992--2007 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.