cc/td/doc/product/ong/15400/r70docs
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table Of Contents

Hardware Specifications

A.1  Shelf Specifications

A.1.1  Bandwidth

A.1.2  Configurations

A.1.3  Cisco Transport Controller

A.1.4  External LAN Interface

A.1.5  TL1 Craft Interface

A.1.6  Modem Interface

A.1.7  Alarm Interface

A.1.8  EIA Interface

A.1.9  BITS Interface

A.1.10  System Timing

A.1.11  System Power

A.1.12  System Environmental Specifications

A.1.13  Dimensions

A.2  SFP, XFP, and GBIC Specifications

A.3  General Card Specifications

A.3.1  Power

A.3.2  Temperature

A.4  Common Control Card Specifications

A.4.1  TCC2 Card Specifications

A.4.2  TCC2P Card Specifications

A.4.3  XCVT Card Specifications

A.4.4  XC10G Card Specifications

A.4.5  XC-VXC-10G Card Specifications

A.4.6  AIC-I Card Specifications

A.4.7  AEP Specifications

A.5  Electrical Card Specifications

A.5.1  EC1-12 Card Specifications

A.5.2  DS1-14 and DS1N-14 Card Specifications

A.5.3  DS1/E1-56 Card Specifications

A.5.4  DS3/EC1-48 Card Specifications

A.5.5  DS3-12 and DS3N-12 Card Specifications

A.5.6  DS3i-N-12 Card Specifications

A.5.7  DS3-12E and DS3N-12E Card Specifications

A.5.8  DS3XM-12 Card Specifications

A.5.9  DS3XM-6 Card Specifications

A.5.10  FILLER Card Specifications

A.6  Optical Card Specifications

A.6.1  OC3 IR 4/STM1 SH 1310 Card Specifications

A.6.2  OC3 IR/STM1SH 1310-8 Card Specifications

A.6.3  OC12 IR/STM4 SH 1310 Card Specifications

A.6.4  OC12 LR/STM4 LH 1310 Card Specifications

A.6.5  OC12 LR/STM4 LH 1550 Card Specifications

A.6.6  OC12 IR/STM4 SH 1310-4 Specifications

A.6.7  OC48 IR 1310 Card Specifications

A.6.8  OC48 LR 1550 Card Specifications

A.6.9  OC48 IR/STM16 SH AS 1310 Card Specifications

A.6.10  OC48 LR/STM16 LH AS 1550 Card Specifications

A.6.11  OC48 ELR/STM 16 EH 100 GHz Card Specifications

A.6.12  OC48 ELR 200 GHz Card Specifications

A.6.13  OC192 SR/STM64 IO 1310 Card Specifications

A.6.14  OC192 IR/STM64 SH 1550 Card Specifications

A.6.15  OC192 LR/STM64 LH 1550 Card Specifications

A.6.16  OC192 LR/STM64 LH ITU 15xx.xx Card Specifications

A.6.17  15454_MRC-12 Card Specifications

A.6.18  OC192SR1/STM64IO Short Reach Card Specifications

A.6.19  OC192/STM64 Any Reach Card Specifications

A.7  Ethernet Card Specifications

A.7.1  E100T-12 Card Specifications

A.7.2  E100T-G Card Specifications

A.7.3  E1000-2 Card Specifications

A.7.4  E1000-2-G Card Specifications

A.7.5  CE-1000-4 Card Specifications

A.7.6  CE-100T-8 Card Specifications

A.7.7  G1K-4 Card Specifications

A.7.8  ML100T-12 Card Specifications

A.7.9  ML1000-2 Card Specifications

A.7.10  ML100X-8 Card Specifications

A.8  Storage Access Networking Card Specifications

A.8.1  FC_MR-4 Card Specifications


Hardware Specifications



Note The terms "Unidirectional Path Switched Ring" and "UPSR" may appear in Cisco literature. These terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring configuration. Rather, these terms, as well as "Path Protected Mesh Network" and "PPMN," refer generally to Cisco's path protection feature, which may be used in any topological network configuration. Cisco does not recommend using its path protection feature in any particular topological network configuration.


This appendix contains hardware and software specifications for the ONS 15454.

A.1  Shelf Specifications

This section provides specifications for shelf bandwidth; a list of topologies; Cisco Transport Controller (CTC) specifications; LAN, TL1, modem, alarm, and electrical interface assembly (EIA) interface specifications; timing, power, and environmental specifications; and shelf dimensions.

A.1.1  Bandwidth

The ONS 15454 has the following bandwidth specifications:

Total bandwidth: 240 Gbps

Data plane bandwidth: 160 Gbps

SONET plane bandwidth: 80 Gbps

A.1.2  Configurations

The ONS 15454 can be configured as follows:

Two-fiber path protection

Path protected mesh network (PPMN)

Two-fiber bidirectional line switch ring (BLSR)

Four-fiber BLSR

Add-drop multiplexer (ADM)

Terminal mode

Regenerator mode

Hubbed rings

Multihubbed rings

Point-to-point

Linear

Linear with optical add/drop multiplexing (OADM)

A.1.3  Cisco Transport Controller

CTC, the ONS 15454 craft interface software, has the following specifications:

10BaseT

TCC2/TCC2P access: RJ-45 connector

Backplane access: LAN pin field

A.1.4  External LAN Interface

The ONS 15454 external LAN interface has the following specifications:

10BaseT Ethernet

Backplane access: LAN pin field

A.1.5  TL1 Craft Interface

The ONS 15454 TL1 craft interface has the following specifications:

Speed: 9600 bps

TCC2/TCC2P access: EIA/TIA-232 DB-9 type connector

Backplane access: CRAFT pin field

A.1.6  Modem Interface

The ONS 15454 modem interface has the following specifications:

Hardware flow control

TCC2/TCC2P: EIA/TIA-232 DB-9 type connector

A.1.7  Alarm Interface

The ONS 15454 alarm interface has the following specifications:

Visual: Critical, Major, Minor, Remote

Audible: Critical, Major, Minor, Remote

Alarm contacts: 0.045 mm, -48 V, 50 mA

Backplane access: Alarm pin fields

A.1.8  EIA Interface

The ONS 15454 EIA interface has the following specifications:

SMB: AMP #415504-3 75-ohm, 4-leg connectors

BNC: Trompeter #UCBJ224 75-ohm 4 leg connector (King and ITT are also compatible)

AMP Champ: AMP#552246-1 with #552562-2 bail locks

A.1.9  BITS Interface

The ONS 15454 building integrated timing supply (BITS) interface has the following specifications:

2 DS-1 BITS inputs

2 derived DS-1 outputs

Backplane access: BITS pin field

A.1.10  System Timing

The ONS 15454 has the following system timing specifications:

Stratum 3 per Telcordia GR-253-CORE

Free running accuracy: +/-4.6 ppm

Holdover stability: 3.7 x10-7 per day, including temperature (< 255 slips in first 24 hours)

Reference: External BITS, line, internal

A.1.11  System Power

The ONS 15454 has the following power specifications:

Input power: -48 VDC

Power consumption: Configuration dependent; 72 W (fan tray only)

Power requirements: -40.5 to -57 VDC

Power terminals: #8-32 screw. Ring or fork type lug suitable for 10 AWG stranded conductor with a 0.375inch maximum width.

ANSI shelf: Two 30 A fuses (customer supplied fuse and alarm panel)

HD shelf: 30 A fuse per shelf (customer supplied fuse and alarm panel)

A.1.12  System Environmental Specifications

The ONS 15454 has the following environmental specifications:

Operating temperature: 0 to +55 degrees Celsius; -40 to +65 degrees Celsius with industrial temperature rated cards

Operating humidity: 5 to 95 percent, noncondensing

A.1.13  Dimensions

The ONS 15454 shelf assembly has the following dimensions:

Height: 18.5 in. (40.7 cm)

Width: 19 or 23 in. (41.8 or 50.6 cm) with mounting ears attached

Depth: 12 in. (26.4 cm) (5 in. or 12.7 cm projection from rack)

Weight: 55 lb (24.947 kg) empty

A.2  SFP, XFP, and GBIC Specifications

Table A-1 lists the specifications for the available Small Form-factor Pluggables (SFPs), 10 Gbps Pluggables (XFPs) and GBICs. In the table, the following acronyms are used:

ESCON = Enterprise System Connection

FICON = fiber connectivity

GE = Gigabit Ethernet

FC = Fibre Channel

HDTV = high definition television

CWDM = coarse wavelength division multiplexing

Table A-1 SFP, XFP, and GBIC Specifications 

SFP/XFP Product ID
Interface
Transmitter Output Power Min/Max (dBm)
Receiver Input Power Min/Max (dBm)

15454-SFP-LC-SX/
15454E-SFP-LC-SX

GE

-9.5 to -4

-17 to 0

15454-SFP-LC-LX/
15454E-SFP-LC-LX

GE

-9.5 to -3

-19 to -3

15454-SFP3-1-IR=

OC-3

-15 to -8

-23 to -8

15454E-SFP-L.1.1=

STM-1

-15 to -8

-34 to -10

15454-SFP12-4-IR=

OC-12, D1 Video

-15 to -8

-28 to -7

15454E-SFP-L.4.1=

STM-4, D1 Video

-15 to -8

-28 to -8

15454-SFP-OC48-IR=

OC-48, DV6000 (C-Cor)

-5 to +0

-18 to +0

ONS-SE-2G-S1=

OC-48, STM-16

-10 to -3

-18 to -3

15454E-SFP-L.16.1=

STM-16, DV6000 (C-Cor)

-5 to +0

-18 to +0

15454-SFP-200/
15454E-SFP-200

ESCON

-8 to -4

-28 to -3

15454-SFP-GEFC-SX=/
15454E-SFP-GEFC-S=

FC (1 and 2 Gbps), FICON, GE

-10 to -3.5

-17 to 0 (1 FC and 1GE)

-15 to 0 (2 FC)

15454-SFP-GE+-LX=/
15454E-SFP-GE+-LX=

FC (1 and 2 Gbps), FICON, GE, HDTV

-9.5 to -3

-20 to -3
(1 FC, 1GE, and 2 FC)

ONS-SE-200-MM=

ESCON

-20.5 to -15

-14 to -291

ONS-SE-G2F-SX=

Fibre Channel (1 and 2 Gbps), GE

-9.5 to 0 (GE)
-10 to -3.5 (1G and 2G FC/FICON)

-17 to 02 (GE)
-22 (1G FC/FICON)
-20 (2G FC/FICON)

ONS-SE-G2F-LX=

Fibre Channel (1 and 2 Gbps), FICON, GE, HDTV

-9.5 to -3 (GE)
-10 to -3.5 (1FC, 2FC, and FICON)

-19 to -33 (GE)
-22 (1G FC/FICON)
-21 (2G FC/FICON)

ONS-SC-GE-SX=

GE

-9.5 to 0

-17 to 02

ONS-SC-GE-LX=

GE

-9.5 to-3

-19 to -33

ONS-SI-2G-S1

OC-48 SR

-10 to -3

-18 to -3

ONS-SI-2G-I1

OC-48 IR1

-5 to 0

-18 to 0

ONS-SI-2G-L1

OC-48 LR1

-2 to 3

-27 to -9

ONS-SI-2G-L2

OC-48 LR2

-2 to 3

-28 to -9

ONS-SC-2G-30.3 through
ONS-SC-2G-60.6

OC-48 DWDM

0 to 4

-28 to -9

ONS-SI-622-I1

OC-3/OC-12 IR1 Dual rate

-15 to -8

-28 to -8

ONS-SI-622-L1

OC-12 LR1

-3 to 2

-28 to -8

ONS-SI-622-L2

OC-12 LR2

-3 to 2

-28 to -8

ONS-SE-622-1470 through
ONS-SE-622-1610

OC-12 CWDM

0 to 5

-28 to -7

ONS-SI-155-I1

OC-3 IR1

-15 to -8

-28 to -8

ONS-SI-155-L1

OC-3 LR1

-5 to 0

-34 to -10

ONS-SI-155-L2

OC-3 LR2

-5 to 0

-34 to -10

ONS_SE-155-1470 through
ONS-SE-155-1610

OC-3 CWDM

0 to 5

-34 to -7

ONS-XC-10G-S1

OC-192 SR1

-6 to -1

-11 to -1

ONS-XC-10G-I2

OC-192 IR2

-1 to +2

-14 to +2

ONS-XC-10G-L2

OC-192 LR2

0 to 4

-24 to -7

ONS-SE-100-FX

Fast Ethernet

-20 to -14

-30 to -14

ONS-SE-100-LX10

Fast Ethernet

-15 to -8

-25 to -8

15454-GBIC-SX

FC, GE

-9.5 to -3.5

-19 to -3

15454E-GBIC-SX

GE, FC

   

15454-GBIC-LX/LH

GE, FC

-9 to -3

-19 to -3

15454E-GBIC-LX/LH

GE, FC

-9 to -3

-19 to -3

ONS-GX-2FC-MMI

FC

-9.5 to -5

-20.5/-15 max

ONS-GX-2FC-SML

FC

-9 to -3

-18 to -3

1 Based on any valid 8B/10B code pattern measured at, or extrapolated to, 10E-15 BER measured at center of eye

2 Minimum Stressed Sensitivity (10-12): -12.5(62.5um) and -13.5(50um) dBm

3 Minimum Stressed Sensitivity (10-12): -14.4 dBm


A.3  General Card Specifications

This section provides power specifications and temperature ranges for all ONS 15454 cards.

A.3.1  Power

Table A-2 provides power consumption information for the ONS 15454 cards.

Table A-2 Individual Card Power Requirements 

Card Type
Card Name
Watts
Amperes
BTU/Hr.
Control Cards

TCC2

19.20

0.4

65.5

TCC2P

27.00

0.56

92.1

XCVT

34.40

0.72

117.34

XC10G

48

1

163.78

XC-VXC-10G

67

1.4

228.62

AIC-I

4.8

0.1

16.4

AEP

3

(0.06 from +5 VDC from AIC-I)

10.2

Electrical Cards

EC1-12

36.60

0.76

124.88

DS1-14

12.60

0.26

43.0

DS1N-14

12.60

0.26

43.0

DS1/E1-56

36.00

0.75

122.84

DS3-12

38.20

0.79

130.34

DS3/EC1-48

45

0.94

153.6

DS3N-12

38.20

0.79

130.34

DS3i-N-12

30

0.63

102.4

DS3-12E

26

0.54

88.7

DS3N-12E

38.2

0.79

130.34

DS3XM-12

34

0.71

116.01

DS3XM-6

20

0.42

68.24

Optical Cards

OC3 IR 4/STM1 SH 1310

19.20

0.4

65.5

 

OC3 IR/STM1SH 1310-8

24.00

0.50

81.89

 

OC12 IR/STM4 SH 1310

10.90

0.23

37.19

 

OC12 LR/STM4 LH 1310

9.28

0.2

31.66

 

OC12 LR/STM4 LH 1550

9.00

0.18

30.71

 

OC12 IR/STM4 SH 1310-4

33.6

0.70

114.65

 

OC48 IR 1310

32.20

0.67

109.87

 

OC48 LR 1550

26.80

0.59

91.45

 

OC48 IR/STM16 SH AS 1310

37.20

0.78

126.93

 

OC48 LR/STM16 LH AS 1550

37.20

0.78

126.93

 

OC48 ELR/STM 16 EH 100 GHz

31.20

0.65

106.46

 

OC48 ELR 200 GHz

31.20

0.65

106.46

 

OC192 SR/STM64 IO 1310

41.80

0.87

142.63

 

OC192 IR/STM64 SH 1550

48.00

1.00

163.78

 

OC192 LR/STM64 LH 1550

41.80

0.87

142.63

 

OC192 LR/STM64 LH ITU 15xx.xx

62.40

1.30

212.92

 

15454_MRC-12

38

0.79

129.66

 

OC192SR1/STM64IO Short Reach1

40

0.83

136.49

 

OC192SR1/STM64IO Any Reach1

40

0.83

136.49

Ethernet Cards

E100T-12

65

1.35

221.79

E100T-G

65

1.35

221.79

E1000-2

53.50

1.11

182.55

E1000-2-G

53.50

1.11

182.55

G1K-4

62.4 (including GBICs2 )

1.30

212.92

ML100T-12

43.2

0.90

147.40

ML1000-2

57.6 (including SFPs)

1.20

196.54

ML100X-8

65

1.35

221.79

CE-100T-8

53.14

1.11

181.32

CE-1000-4

60

1.25

204.73

Storage Access Networking

FC_MR-4

60

1.25

204.73

1 Designated as OC192-XFP in CTC.

2 GBICs = Gigabit Interface Converters


A.3.2  Temperature

Table A-3 provides temperature ranges and product names for ONS 15454 cards.


Note The I-Temp symbol is displayed on the faceplate of an I-Temp compliant card. A card without this symbol is C-Temp compliant.


Table A-3 Card Temperature Ranges and Product Names 

Card Type
Card Name
C-Temp Product Name
(32 to 131 degrees Fahrenheit, 0 to +55 degrees Celsius)
I-Temp Product Name
(-40 to 149 degrees Fahrenheit, -40 to +65 degrees Celsius)
Control Cards

TCC2

15454-TCC2

TCC2P

15454-TCC2P

XCVT

15454-XC-VT

15454-XC-VT-T

XC10G

15454-XC-10G

XC-VXC-10G

15454-XC-VXC-10G-T

AIC-I

15454-AIC-I

AEP

15454-AEP

Electrical

EC1-12

15454-EC1-12

15454-EC1-12-T

DS1-14

15454-DS1-14

15454-DS1-14-T

DS1N-14

15454-DS1N-14

15454-DS1N-14-T

DS1/E1-56

15454-DS1E1-56

DS3-12

15454-DS3-12

15454-DS3-12-T

DS3/EC1-48

15454-DS3_EC1-48

DS3N-12

15454-DS3N-12

15454-DS3N-12-T

DS3i-N-12

15454-DS3i-N-12

DS3-12E

15454-DS3-12E-T

DS3N-12E

15454-DS3N-12E-T

DS3XM-12 (Transmux)

15454-DS3XM-12

DS3XM-6 (Transmux)

15454-DS3XM-6

15454-DS3XM-6-T

Optical

OC3 IR 4/STM1 SH 1310

15454-OC34IR1310

15454-OC34I13-T

OC3 IR/STM1 SH 1310-8

15454-OC3I8-1310

OC12 IR/STM4 SH 1310

15454-OC121IR1310

15454-OC121I13-T

OC12 LR/STM4 LH 1310

15454-OC121LR1310

15454-OC121L13-T

OC12 LR/STM4 LH 1550

15454-OC121LR1550

15454-OC121L15-T

OC12 IR/STM4 SH 1310-4

15454-OC12I4-1310

OC48 IR 1310

15454-OC481IR1310

OC48 LR 1550

15454-OC481LR1550

OC48 IR/STM16 SH AS 1310

15454-OC481IR1310A

OC48 LR/STM16 LH AS 1550

15454-OC481LR1550A

OC48 ELR/STM16 EH 100 GHz

15454-OC48E-1-xx.xx
(all wavelengths)

OC48 ELR/STM16 EH 200 GHz

15454-OC48E-xx.xx
(all wavelengths)

Optical

OC 192 SR/STM64 IO 1310

15454-OC192IO1310

OC192 IR/STM64 SH 1550

15454-OC192IR1550

OC192 LR/STM64 LH 1550

15454-OC192LR1550

OC192 LR/STM64 LH ITU 15xx.xx

15454-OC192LR15xx

15454_MRC-12

15454-MRC-12-T

OC-192/STM-64 SR1 Short Reach1

15454_OC-192/STM-64 SR1 Short Reach

OC-192/STM-64 Any Reach 1

15454_OC-192/STM-64 Any Reach

Ethernet

E100T-12

15454-E100T

E100T-G

15454-E100T-G

E1000-2

15454-E1000-2

E1000-2-G

15454-E1000-2-G

G1K-4

15454-G1K-4

ML100T-12

15454-ML100T-12

ML1000-2

15454-ML1000-2

ML100X-8

15454-ML100X-8

CE-100T-8

15454-CE100T-8

CE-1000-4

15454-CE1000-4

Storage Access Networking

FC_MR-4

15454-FC_MR-4

1 Designated as OC192-XFP in CTC.


A.4  Common Control Card Specifications

This section provides specifications for the TCC2, TCC2P, XCVT, XC10G, XC-VXC-10G, and AIC-I cards.

For compliance information, refer to the Cisco Optical Transport Products Safety and Compliance Information document.

A.4.1  TCC2 Card Specifications

The TCC2 card has the following specifications:

CTC software

Interface: EIA/TIA-232 (local craft access, on TCC2 faceplate)

Interface: 10BaseT LAN (on TCC2 faceplate)

Interface: 10BaseT LAN (through the backplane)

Synchronization

Stratum 3, per Telcordia GR-253-CORE

Free running access: Accuracy +/- 4.6 ppm

Holdover stability: 3.7 * 10 exp - 7 per day including temperature (< 255 slips in first 24 hours)

Reference: External BITS, line, internal

Supply voltage monitoring

Both supply voltage inputs are monitored.

Normal operation: -40.5 to -56.7 V

Undervoltage: Major alarm

Overvoltage: Major alarm

Environmental

Operating temperature: -40 to +149 degrees Fahrenheit (-40 to +65 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Depth with backplane connector: 9.250 in. (235 mm)

Weight not including clam shell: 1.5 lb (0.7 kg)

A.4.2  TCC2P Card Specifications

The TCC2P card has the following specifications:

CTC software

Interface: EIA/TIA-232 (local craft access, on TCC2P faceplate)

Interface: 10BaseT LAN (on TCC2P faceplate)

Interface: 10BaseT LAN (via backplane)

Synchronization

Stratum 3, per Telcordia GR-253-CORE

Free running access: Accuracy +/- 4.6 ppm

Holdover stability: 3.7 * 10 exp - 7 per day including temperature (< 255 slips in first 24 hours)

Reference: External BITS, line, internal

Supply voltage monitoring

Both supply voltage inputs are monitored.

Normal operation: -40.5 to -56.7 V (in -48 VDC systems)

Undervoltage: Major alarm

Overvoltage: Major alarm

Environmental

Operating temperature: -40 to +149 degrees Fahrenheit (-40 to +65 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Depth with backplane connector: 9.250 in. (235 mm)

Weight not including clam shell: 1.5 lb (0.7 kg)

A.4.3  XCVT Card Specifications

The XCVT card has the following specifications:

Environmental

Operating temperature:

C-Temp (15454-XC-VT): 32 to 131 degrees Fahrenheit (0 to +55 degrees Celsius)

I-Temp (15454-XC-VT-T): -40 to 149 degrees Fahrenheit (-40 to +65 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Card weight: 1.9 lb (0.8 kg)

A.4.4  XC10G Card Specifications

The XC10G card has the following specifications:

Environmental

Operating temperature:

C-Temp (15454-XC-10G): 32 to 131 degrees Fahrenheit (0 to +55 degrees Celsius)

Operating humidity: 5 to 85 percent, noncondensing

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Card weight: 1.5 lb (0.6 kg)

A.4.5  XC-VXC-10G Card Specifications

The XC-VXC-10G card has the following specifications:

Environmental

Operating temperature:

I-Temp (15454-XC-VXC-10G-T): -40 to 149 degrees Fahrenheit (-40 to +65 degrees Celsius)

Operating humidity: 5 to 85 percent, noncondensing

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Card weight: 1.5 lb (0.6 kg)

A.4.6  AIC-I Card Specifications

The AIC-I card has the following specifications:

Alarm inputs

Number of inputs: 12 without alarm extension panel (AEP), 32 with AEP

Opto coupler isolated

Label is customer provisionable.

Severity is customer provisionable.

Common 32 V output for all alarm inputs

Each input limited to 2 mA

Termination: Wire-wrap on backplane without AEP, on AEP connectors with AEP

Alarm outputs

Number of outputs: 4 (user configurable as inputs) without AEP, 16 with AEP

Switched by opto MOS (metal oxide semiconductor)

Triggered by definable alarm condition

Maximum allowed open circuit voltage: 60 VDC

Maximum allowed closed circuit current: 100 mA

Termination: Wire-wrap on backplane without AEP, on AEP connectors with AEP

Express orderwire/Local orderwire (EOW/LOW)

ITU-T G.711, ITU-T G.712, Telcordia GR-253-CORE

A-law, mu-law


Note Due to the nature of mixed coding, in a mixed-mode configuration (A-law/mu-law) the orderwire is not ITU-T G.712 compliant.


Orderwire party line

Dual tone multifrequency (DTMF) signaling

User data channel (UDC)

Bit rate: 64 kbps, bidirectional

ITU-T G.703

Input/output impedance: 120 ohm

Termination: RJ-11 connectors

Data communications channel (DCC)

Bit rate: 576 kbps

EIA/TIA-485/V11

Input/output impedance: 120 ohm

Termination: RJ-45 connectors

ACC connection for additional alarm interfaces

Connection to AEP

Power monitoring alarming states:

Power failure (0 to -38 VDC)

Undervoltage (-38 to -40.5 VDC)

Overvoltage (beyond -56.7 VDC)

Environmental

Operating temperature: -40 to 149 degrees Fahrenheit (-40 to +65 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Card weight: 1.8 lb (0.82 kg)

A.4.7  AEP Specifications

The AEP has the following specifications:

Alarm inputs

Number of inputs: 32

Optocoupler isolated

Label customer provisionable

Severity customer provisionable

Common 32 V output for all alarm inputs

Each input limited to 2 mA

Termination: 50-pin AMP champ connector

Alarm outputs

Number of outputs: 16

Switched by opto MOS

Triggered by definable alarm condition

Maximum allowed open circuit voltage: 60 VDC

Maximum allowed closed circuit current: 100 mA

Termination: 50-pin AMP champ connector

Environmental

Overvoltage protection: as in ITU-T G.703 Annex B

Operating temperature: -40 to +65 degrees Celsius

Operating humidity: 5 to 95 percent, noncondensing

Dimensions of AEP board

Height: 0.79 in. (20 mm)

Width: 13.0 in. (330 mm)

Depth: 3.5 in. (89 mm)

Weight: 0.4 lb (0.18 kg)

A.5  Electrical Card Specifications

This section provides specifications for the EC1-12, DS1-14, DS1N-14, DS1/E1-56, DS3/EC1-48, DS3-12, DS3N-12, DS3i-N-12, DS3-12E, DS3N-12E, DS3XM-6, DS3XM-12, and filler cards.

For compliance information, refer to the Cisco Optical Transport Products Safety and Compliance Information document.

A.5.1  EC1-12 Card Specifications

The EC1-12 card has the following specifications:

Input

Bit rate: 51.84 Mbps +/- 20 ppm

Frame format: SONET

Line code: B3ZS

Termination: Unbalanced coaxial cable

Input impedance: 75 ohms +/- 5 percent

Cable loss: Max 450 feet 734A, RG-59, 728A/Max 79 feet RG-179

AIS: TR-TSY-000191 compliant

Output

Bit rate: 51.84 Mbps +/- 20 ppm

Frame format: SONET

Line code: B3ZS

Termination: Unbalanced coaxial cable

Input impedance: 75 ohms +/-5 percent

Cable loss: Max 450 feet 734A, RG-59, 728A/Max 79 feet RG-179

AIS: TR-TSY-000191 compliant

Power level: -1.8 +/- 5.7 dBm

Pulse shape: ANSI T1.102-1988 Figure 8

Pulse amplitude: 0.36 to 0.85 V peak to peak

Loopback modes: Terminal and facility

Line build out: 0 to 225 feet (0 to 68.8 meters); 226 to 450 feet (68.9 to 137.2 meters)

Electrical interface: BNC or SMB connectors

Operating temperature

C-Temp (15454-EC1-12): 0 to 131 degrees Fahrenheit (0 to +55 degrees Celsius)

I-Temp (15454-EC1-12-T): -40 to 149 degrees Fahrenheit (-40 to +65 degrees Celsius)


Note The I-Temp symbol is displayed on the faceplate of an I-Temp compliant card. A card without this symbol is C-Temp compliant.


Operating humidity: 5 to 95 percent, noncondensing

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Card weight: 2.0 lb (0.9 kg)

A.5.2  DS1-14 and DS1N-14 Card Specifications

The DS1-14 and DS1N-14 cards have the following specifications:

Input

Bit rate: 1.544 Mbps +/- 32 ppm

Frame format: Off, SF (D4), ESF

Line code: AMI, B8ZS

Termination: Wire-wrap, AMP Champ

Input impedance: 100 ohms

Cable loss: Max 655 feet ABAM #22 AWG

AIS: TR-TSY-000191 compliant

Output

Bit rate: 1.544 Mbps +/- 32 ppm

Frame format: Off, SF (D4), ESF

Line code: AMI, B8ZS

Termination: Wire-wrap, AMP Champ

Input impedance: 100 ohms

Cable loss: Max 655 feet ABAM #22 AWG

AIS: TR-TSY-000191 compliant

Power level: 12.5 to 17.9 dBm centered at 772 KHz, -16.4 to -11.1 dBm centered at 1544 KHz

Pulse shape: Telcordia GR-499-CORE Figure 9-5

Pulse amplitude: 2.4 to 3.6 V peak-to-peak

Loopback modes: Terminal and facility

Electrical interface: BNC or SMB connectors

Surge protection: Telcordia GR-1089

Operating temperature

C-Temp (15454-DS1-14 and 15454-DS1N-14): 0 to 131 degrees Fahrenheit (0 to +55 degrees Celsius)

I-Temp (15454-DS1-14-T and 15454-DS1N-14-T): -40 to 149 degrees Fahrenheit (-40 to +65 degrees Celsius)


Note The I-Temp symbol is displayed on the faceplate of an I-Temp compliant card. A card without this symbol is C-Temp compliant.


Operating humidity: 5 to 95 percent, noncondensing

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Card weight: 1.8 lb (0.8 kg)

A.5.3  DS1/E1-56 Card Specifications

The DS1/E1-56 card has the following specifications:

Input

Bit rate: 1.544 Mbps ± 32 ppm (DS-1); 2.048 Mbps ±50ppm (E1)

Frame format: Off, SF (D4), ESF (DS-1); E1 multiframe, E1 CRC multiframe, and unframed (ITU) (E1)

Line code: AMI, B8ZS (DS-1); HDB3 (E1)

Termination: Balanced, twisted pair, #22/24 AWG

Input impedance: 100 ohms +/- 5 percent (DS1); 120 ohms =/-5% (E1)

Cable loss: Max 655 feet ABAM #22/24 AWG (DS1); Compliant per ITU-T G.703 (E1)

AIS: TR-TSY-000191 compliant

Output

Bit rate: 1.544 Mbps ± 32 ppm (DS-1); 2.048 Mbps ±50ppm (E1)

Frame format: Off, SF (D4), ESF (DS-1); E1 multiframe, E1 CRC multiframe, and unframed (ITU) (E1)

Line code: AMI, B8ZS (DS-1); HDB3 (E1)

Termination: Balanced, twisted pair, #22/24 AWG

Input impedance: 100 ohms +/- 5 percent (DS1); 120 ohms =/-5% (E1)

Cable loss: Max 655 feet ABAM #22/24 AWG (DS1); Compliant per ITU-T G.703 (E1)

AIS: TR-TSY-000191 compliant

Power level: 12.6 to 17.9 dBm centered at 772 KHz

Pulse shape: Telcordia GR-499-CORE Figure 9-5 (DS-1); ITU-T G.703, Figure 15 (E1)

Pulse amplitude: 2.4 to 3.6 V peak-to-peak (DS-1); 2.7 to 3.3 V peak-to-peak (E1)

Loopback modes: Terminal and facility

Electrical interface: SCSI (UBIC) connectors. UBIC-H: DS-1 and E1; UBIC-V: DS-1 only.

Surge protection: Telcordia GR-1089

Operating temperature

I-Temp (15454-DS1E1-56):-40 to 149 degrees Fahrenheit (-40 to +65 degrees Celsius)


Note The I-Temp symbol is displayed on the faceplate of an I-Temp compliant card. A card without this symbol is C-Temp compliant.


Operating humidity: 5 to 95 percent, noncondensing

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Card weight: 2.0 lb (0.9 kg)

A.5.4  DS3/EC1-48 Card Specifications

The DS3/EC1-48 card has the following specifications:

Input

Bit rate: 44.736 Mbps +/- 20 ppm

Frame format: DS-3 ANSI T1.107-1988

Line code: B3ZS

Termination: Unbalanced coaxial cable

Input impedance: 75 ohms +/-5 percent

Cable loss: Max 450 feet with 734A or 728A, Max 79 feet with RG-179

AIS: TR-TSY-000191 compliant

Output

Bit rate: 44.736 Mbps +/- 20 ppm

Frame format: DS-3 ANSI T1.107-1988

Line code: B3ZS

Termination: Unbalanced coaxial cable

Input impedance: 75 ohms +/-5 percent

Cable loss: Max 900 feet with 734A or 728A cable, Max 79 feet with RG-179

AIS: TR-TSY-000191 compliant

Power level: -1.8 to +5.7 dBm

Pulse shape: ANSI T1.102-1988 Figure 8

Pulse amplitude: 0.36 to 0.85 V peak

Loopback modes: Terminal and facility

Line build out: 0 to 225 feet (0 to 68.8 meters); 226 to 450 feet (68.9 to 137.2 meters)

Electrical interface: BNC or SMB connectors

Surge protection: Telcordia GR-1089

Operating temperature:

I-Temp (15454-DS3_EC1-48): -40 to 149 degrees Fahrenheit (-40 to +65 degrees Celsius)


Note The I-Temp symbol is displayed on the faceplate of an I-Temp compliant card. A card without this symbol is C-Temp compliant.


Operating humidity: 5 to 95 percent, noncondensing

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Weight: 1.7 lb (0.7 kg)

A.5.5  DS3-12 and DS3N-12 Card Specifications

The DS3-12 and DS3N-12 cards have the following specifications:

Input

Bit rate: 44.736 Mbps +/- 20 ppm

Frame format: DS-3 ANSI T1.107-1988

Line code: B3ZS

Termination: Unbalanced coaxial cable

Input impedance: 75 ohms +/-5 percent

Cable loss: Max 450 feet 734A, RG-59, 728A/Max 79 feet RG-179

AIS: TR-TSY-000191 compliant

Output

Bit rate: 44.736 Mbps +/- 20 ppm

Frame format: DS-3 ANSI T1.107-1988

Line code: B3ZS

Termination: Unbalanced coaxial cable

Input impedance: 75 ohms +/-5 percent

Cable loss: Max 450 feet 734A, RG-59, 728A/Max 79 feet RG-179

AIS: TR-TSY-000191 compliant

Power level: -1.8 to +5.7 dBm

Pulse shape: ANSI T1.102-1988 Figure 8

Pulse amplitude: 0.36 to 0.85 V peak-to-peak

Loopback modes: Terminal and facility

Line build out: 0 to 225 feet (0 to 68.8 meters); 226 to 450 feet (68.9 to 137.2 meters)

Electrical interface: BNC or SMB connectors

Surge protection: Telcordia GR-1089

Operating temperature

C-Temp (15454-DS3-12 and 15454-DS3N-12): 0 to 131 degrees Fahrenheit (0 to +55 degrees Celsius)

I-Temp (15454-DS3-12-T and 15454-DS3N-12-T): -40 to 149 degrees Fahrenheit (-40 to +65 degrees Celsius)


Note The I-Temp symbol is displayed on the faceplate of an I-Temp compliant card. A card without this symbol is C-Temp compliant.


Operating humidity: 5 to 95 percent, noncondensing

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

DS3-12 card weight: 1.7 lb (0.7 kg)

DS3N-12 card weight: 1.8 lb (0.8 kg)

A.5.6  DS3i-N-12 Card Specifications

The DS3i-N-12 card has the following specifications:

Input

Bit rate: 44.736 Mbps +/-20 ppm

Frame format: ITU-T G.704, ITU-T G.752/DS-3 ANSI T1.107-1988

Line code: B3ZS

Termination: Unbalanced coaxial cable

Input impedance: 75 ohms +/- 5 percent

Cable loss:
Maximum 137 m (450 ft): 734A, RG59, 728A
Maximum 24 m (79 ft): RG179

AIS: ITU-T G.704 compliant

Output

Bit rate: 44.736 Mbps +/- 20 ppm

Frame format: ITU-T G.704, ITU-T G.752/DS-3 ANSI T1.107-1988

Line code: B3ZS

Termination: Unbalanced coaxial cable

Output impedance: 75 ohms +/-5 percent

AIS: ITU-T G.704 compliant

Power level: -1.8 to +5.7 dBm


Note The power level is for a signal of all ones and is measured at a center frequency of 22.368 MHz (3 +/-1 kHz) bandwidth.)


Pulse shape: ITU-T G.703, Figure 14/ANSI T1.102-1988, Figure 8

Pulse amplitude: 0.36 to 0.85 V peak-to-peak

Loopback modes: Terminal and facility

Line build out: 0 to 225 feet (0 to 68.8 meters); 226 to 450 feet (68.9 to 137.2 meters)

Electrical interface connectors: SMB, BNC

Environmental

Overvoltage protection: As in ITU-T G.703 Annex B

Operating temperature: +23 to +113 degrees Fahrenheit (-5 to +45 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Depth with backplane connector: 9.250 in. (235 mm)

Weight not including clam shell: 1.9 lb (0.8 kg)

A.5.7  DS3-12E and DS3N-12E Card Specifications

The DS3-12E and DS3N-12E cards have the following specifications:

Input

Bit rate: 44.736 Mbps +/- 20 ppm

Frame format: DS-3 ANSI T1.107-1988

Line code: B3ZS

Termination: Unbalanced coaxial cable

Input impedance: 75 ohms +/-5 percent

Cable loss: Max 450 feet 734A, RG-59, 728A/Max 79 feet RG-179

AIS: TR-TSY-000191 compliant

Output

Bit rate: 44.736 Mbps +/- 20 ppm

Frame format: DS-3 ANSI T1.107-1988

Line code: B3ZS

Termination: Unbalanced coaxial cable

Input impedance: 75 ohms +/-5 percent

Cable loss: Max 450 feet 734A, RG-59, 728A/Max 79 feet RG-179

AIS: TR-TSY-000191 compliant

Power level: -1.8 to +5.7 dBm


Note The power level is for a signal of all ones and is measured at a center frequency of 22.368 MHz (3 +/-1 kHz) bandwidth.


Pulse shape: ANSI T1.102-1988 Figure 8

Pulse amplitude: 0.36 to 0.85 V peak-to-peak

Loopback modes: Terminal and facility

Line build out: 0 to 225 feet (0 to 68.8 meters); 226 to 450 feet (68.9 to 137.2 meters)

Electrical interface: Connectors: BNC or SMB

Surge protection: Telcordia GR-1089

Operating temperature: I-Temp (15454-DS3-12E-T and 15454-DS3N-12E-T): -40 to 149 degrees Fahrenheit (-40 to +65 degrees Celsius)


Note The I-Temp symbol is displayed on the faceplate of an I-Temp compliant card. A card without this symbol is C-Temp compliant.


Operating humidity: 5 to 95 percent, noncondensing

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Depth with backplane connector: 9.250 in. (235.0 mm)

DS3-12E card weight: 1.8 lb (0.8 kg)

DS3N-12E card weight: 1.9 lb (0.8 kg)

A.5.8  DS3XM-12 Card Specifications

The DS3XM-12 card has the following specifications:

Input

Bit rate: 44.736 Mbps +/-20 ppm

Frame format: DS-3 ANSI T1.107-1988

Line code: B3ZS

Termination: Unbalanced coaxial cable

Input impedance: 75 ohms +/-5 percent

Cable loss: Max 450 feet 734A, RG-59, 728A/Max 79 feet RG-179

AIS: TR-TSY-000191 compliant

Output

Bit rate: 44.736 Mbps +/- 20 ppm

Frame format: DS-3 ANSI T1.107-1988

Line code: B3ZS

Termination: Unbalanced coaxial cable

Input impedance: 75 ohms +/-5 percent

Cable loss: Max 450 feet 734A, RG-59, 728A/Max 79 feet RG-179

AIS: TR-TSY-000191 compliant

Power level: -1.8 to +5.7 dBm

Pulse shape: ANSI T1.102-1988 Figure 8

Pulse amplitude: 0.36 to 0.85 V peak-to-peak

Loopback modes: Terminal and facility

Line build out: 0 to 225 feet (0 to 68.8 meters); 226 to 450 feet (68.9 to 137.2 meters)

Interface: BNC, SMB, UBIC and MiniBNC connectors

Surge protection: Telcordia GR-1089

Operating temperature:

I-Temp (15454-DS3XM-12): -40 to 149 degrees Fahrenheit (-40 to +65 degrees Celsius)


Note The I-Temp symbol is displayed on the faceplate of an I-Temp compliant card. A card without this symbol is C-Temp compliant.


Operating humidity: 5 to 95 percent, noncondensing

Dimensions

Height: 12.65 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.00 in. (228.6 mm)

Card weight: 1.8 lb (0.8 kg)

A.5.9  DS3XM-6 Card Specifications

The DS3XM-6 card has the following specifications:

Input

Bit rate: 44.736 Mbps +/-20 ppm

Frame format: DS-3 ANSI T1.107-1988

Line code: B3ZS

Termination: Unbalanced coaxial cable

Input impedance: 75 ohms +/-5 percent

Cable loss: Max 450 feet 734A, RG-59, 728A/Max 79 feet RG-179

AIS: TR-TSY-000191 compliant

Output

Bit rate: 44.736 Mbps +/- 20 ppm

Frame format: DS-3 ANSI T1.107-1988

Line code: B3ZS

Termination: Unbalanced coaxial cable

Input impedance: 75 ohms +/-5 percent

Cable loss: Max 450 feet 734A, RG-59, 728A/Max 79 feet RG-179

AIS: TR-TSY-000191 compliant

Power level: -1.8 to +5.7 dBm

Pulse shape: ANSI T1.102-1988 Figure 8

Pulse amplitude: 0.36 to 0.85 V peak-to-peak

Loopback modes: Terminal and facility

Line build out: 0 to 225 feet (0 to 68.8 meters); 226 to 450 feet (68.9 to 137.2 meters)

Interface: BNC or SMB connectors

Surge protection: Telcordia GR-1089

Operating temperature:

C-Temp (15454-DS3XM-6): 0 to 131 degrees Fahrenheit (0 to +55 degrees Celsius)

I-Temp (15454-DS3XM-6-T): -40 to 149 degrees Fahrenheit (-40 to +65 degrees Celsius)


Note The I-Temp symbol is displayed on the faceplate of an I-Temp compliant card. A card without this symbol is C-Temp compliant.


Operating humidity: 5 to 95 percent, noncondensing

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Card weight: 1.8 lb (0.8 kg)

A.5.10  FILLER Card Specifications

The FILLER cards have the following specifications:

Environmental

Operating temperature:

C-Temp: -40 to +149 degree Fahrenheit (-40 to +65 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Card weight: 0.4 lb (0.19 kg)

A.6  Optical Card Specifications

This section provides specifications for the OC3 IR4/STM1 SH 1310 (four-port), OC3 IR/STM1 SH 1310-8 (eight-port), OC12 IR/STM4 SH 1310, OC12 LR/STM4 LH 1310, OC12 LR STM4 LH 1550, OC12 IR/STM4 SH 1310-4 (four-port), OC48 IR 1310, OC48 LR 1550, OC48 IR/STM16 SH AS 1310, OC48 LR/STM16 LH AS 1550, OC48 ELR 100 GHz, OC48 ELR 200 GHz, OC192 SR/STM64 IO 1310, OC192 IR/STM64 SH 1550, OC192 LR/STM64 LH 1550, OC192 LR/STM64 LH ITU 15xx.xx, 15454_MRC-12 (12-port), OC192SR1/STM64IO Short Reach, and OC192/STM64 Any Reach cards.

For compliance information, refer to the Cisco Optical Transport Products Safety and Compliance Information.

A.6.1  OC3 IR 4/STM1 SH 1310 Card Specifications

The OC3 IR 4/STM1 SH 1310 card has the following specifications:

Line

Bit rate: 155.52 Mbps

Code: Scrambled non-return to zero (NRZ)

Fiber: 1310-nm single-mode

Loopback modes: Terminal and facility

Connector: SC

Compliance: Telcordia GR-253-CORE, ITU-T G.707, ITU-T G.957

Transmitter

Maximum transmitter output power: -8 dBm

Minimum transmitter output power: -15 dBm

Center wavelength: 1274 to 1356 nm

Nominal wavelength: 1310 nm

Transmitter: Fabry Perot (FP) laser

Extinction Ratio: 8.2 dB

Dispersion Ratio: 96 ps/nm

Receiver

Maximum receiver level: -8 dBm at BER 1 * 10 exp - 12

Minimum receiver level: -28 dBm at BER 1 * 10 exp - 12

Receiver: InGaAs/InP photodetector

Link loss budget: 13 dB

Receiver input wavelength range: 1274 to 1356 nm

Jitter tolerance: Telcordia GR-253/ITU-T G.823 compliant

Environmental

Operating temperature:

C-Temp (15454-OC34IR1310): +23 to +113 degrees Fahrenheit (-5 to +45 degrees Celsius)

I-Temp (15454-OC34I13-T): -40 to 149 degrees Fahrenheit (-40 to +65 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Depth with backplane connector: 9.250 in. (235 mm)

Weight not including clam shell: 1.0 lb (0.4 kg)

A.6.2  OC3 IR/STM1SH 1310-8 Card Specifications

The OC3 IR/STM1SH 1310-8 card has the following specifications:

Line

Bit rate: 155.52 Mbps

Code: Scrambled NRZ

Fiber: 1310-nm single-mode

Loopback modes: Terminal and facility

Connector: LC

Compliance: Telcordia GR-253-CORE, ITU-T G.707, ITU-T G.957

Transmitter

Maximum transmitter output power: -8 dBm

Minimum transmitter output power: -15 dBm

Center wavelength: 1261 to 1360 nm

Nominal wavelength: 1310 nm

Transmitter: Fabry Perot laser

Extinction ratio: 8.2 dB

Dispersion tolerance: 96 ps/nm

Receiver

Maximum receiver level: -8 dBm at BER 1 * 10 exp - 12

Minimum receiver level: -28 dBm at BER 1 * 10 exp - 12

Receiver: InGaAs/InP photodetector

Link loss budget: 13 dB

Receiver input wavelength range: 1261 to 1360 nm

Jitter tolerance: Telcordia GR-253/ITU-T G.823 compliant

Environmental

Operating temperature: +23 to +113 degrees Fahrenheit (-5 to +45 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Depth with backplane connector: 9.250 in. (235 mm)

Weight not including clam shell: 1.0 lb (0.4 kg)

A.6.3  OC12 IR/STM4 SH 1310 Card Specifications

The OC12 IR/STM4 SH 1310 card has the following specifications:

Line

Bit rate: 622.08 Mbps

Code: Scrambled NRZ

Fiber: 1310-nm single-mode

Loopback modes: Terminal and facility

Connectors: SC

Compliance: Telcordia GR-253-CORE, ITU-T G.707, ITU-T G.957

Transmitter

Maximum transmitter output power: -8 dBm

Minimum transmitter output power: -15 dBm

Center wavelength: 1274 to 1356 nm

Nominal wavelength: 1310 nm

Transmitter: Fabry Perot laser

Extinction ratio: 8.2 dB

Dispersion tolerance: 96 ps/nm

Receiver

Maximum receiver level: -8 dBm at BER 1 * 10 exp - 12

Minimum receiver level: -28 dBm at BER 1 * 10 exp - 12

Receiver: InGa As/InP photodetector

Link loss budget: 13 dB

Receiver input wavelength range: 1274 to 1356 nm

Jitter tolerance: Telcordia GR-253/ITU-T G.823 compliant

Environmental

Operating temperature:

C-Temp (15454-OC121IR1310): +23 to +131 degrees Fahrenheit (-5 to +55 degrees Celsius)

I-Temp (15454-OC121I13-T): -40 to +149 degrees Fahrenheit (-40 to +65 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Weight not including clam shell: 1.4 lb (0.6 kg)

A.6.4  OC12 LR/STM4 LH 1310 Card Specifications

The OC12 LR/STM4 LH 1310 card has the following specifications:

Line

Bit rate: 622.08 Mbps

Code: Scrambled NRZ

Fiber: 1310-nm single-mode

Loopback modes: Terminal and facility

Connectors: SC

Compliance: Telcordia SONET, Telcordia GR-253-CORE, ITU-T G.707, ITU-T G.957

Transmitter

Maximum transmitter output power: +2 dBm

Minimum transmitter output power: -3 dBm

Center wavelength: 1280 to 1335 nm

Nominal wavelength: 1310 nm

Transmitter: Distributed feedback (DFB) laser

Extinction ratio: 10 dB

Dispersion tolerance: 190 ps/nm

Receiver

Maximum receiver level: -8 dBm at BER 1 * 10 exp - 12

Minimum receiver level: -28 dBm at BER 1 * 10 exp - 12

Receiver: InGaAs/InP photodetector

Link loss budget: 25 dB

Receiver input wavelength range: 1280 to 1335 nm

Jitter tolerance: Telcordia GR-253/ITU-T G.823 compliant

Environmental

Operating temperature:

C-Temp (15454-OC121LR1310): +23 to +131 degrees Fahrenheit (-5 to +55 degrees Celsius)

I-Temp (15454-OC121L13-T): -40 to +149 degrees Fahrenheit (-40 to +65 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Weight not including clam shell: 1.4 lb (0.6 kg)

A.6.5  OC12 LR/STM4 LH 1550 Card Specifications

The OC12 LR/STM4 LH 1550 card has the following specifications:

Line

Bit rate: 622.08 Mbps

Code: Scrambled NRZ

Fiber: 1550-nm single-mode

Loopback modes: Terminal and facility

Connectors: SC

Compliance: Telcordia SONET, Telcordia GR-253-CORE, ITU-T G.707, ITU-T G.957

Transmitter

Maximum transmitter output power: +2 dBm

Minimum transmitter output power: -3 dBm

Center wavelength: 1480 to 1580 nm

Nominal wavelength: 1550 nm

Transmitter: DFB laser

Dispersion tolerance: 1440 ps/nm

Receiver

Maximum receiver level: -8 dBm at BER 1 * 10 exp - 12

Minimum receiver level: -28 dBm at BER 1 * 10 exp - 12

Receiver: InGaAs/InP photodetector

Link loss budget: 25 dB

Receiver input wavelength range: 1480 to 1580 nm

Jitter tolerance: Telcordia GR-253/ITU-T G.823 compliant

Environmental

Operating temperature:

C-Temp (15454-OC121LR1550): +23 to +131 degrees Fahrenheit (-5 to +55 degrees Celsius)

I-Temp (15454-OC121L15-T): -40 to +149 degrees Fahrenheit (-40 to +65 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Weight not including clam shell: 1.4 lb (0.6 kg)

A.6.6  OC12 IR/STM4 SH 1310-4 Specifications

The OC12 IR/STM4 SH 1310-4 card has the following specifications:

Line

Bit rate: 622.08 Mbps

Code: Scrambled NRZ

Fiber: 1310-nm single-mode

Loopback modes: Terminal and facility

Connector: SC

Compliance: Telcordia GR-253-CORE, ITU-T G.707, ITU-T G.957

Transmitter

Maximum transmitter output power: -8 dBm

Minimum transmitter output power: -15 dBm

Center wavelength: 1274 to 1356 nm

Nominal wavelength: 1310 nm

Transmitter: Fabry Perot laser

Extinction ratio: 10 dB

Dispersion tolerance: 190 ps/nm

Receiver

Maximum receiver level: -8 dBm

Minimum receiver level: -30 dBm

Receiver: InGaAs/InP photodetector

Link loss budget: 15 dB

Receiver input wavelength range: 1274 to 1356 nm

Jitter tolerance: Telcordia GR-253/ITU-T G.823 compliant

Operating temperature

C-Temp: +23 to +131 degrees Fahrenheit (-5 to +55 degrees Celsius)

Operating humidity

5 to 95 percent, noncondensing

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Weight not including clam shell: 1.0 lb (0.4 kg)


Note Minimum transmit power, minimum receive power, and link loss budget might exceed standard specifications.


A.6.7  OC48 IR 1310 Card Specifications

The OC48 IR 1310 card has the following specifications:

Line

Bit rate: 2.49 Gbps

Code: Scrambled NRZ

Fiber: 1310-nm single-mode

Loopback modes: Terminal and facility

Connectors: SC

Compliance: Telcordia GR-253-CORE

Transmitter

Maximum transmitter output power: 0 dBm

Minimum transmitter output power: -5 dBm

Center wavelength: 1280 to 1350 nm

Nominal wavelength: 1310 nm

Transmitter: Uncooled direct modulated DFB

Receiver

Maximum receiver level: 0 dBm

Minimum receiver level: -18 dBm

Receiver: InGaAs InP photodetector

Link loss budget: 13 dB minimum

Receiver input wavelength range: 1280 to 1350 nm

Environmental

Operating temperature:

C-Temp (15454-OC481IR1310): +23 to +131 degrees Fahrenheit (-5 to +55 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Weight not including clam shell: 1.8 lb (0.8 kg)

A.6.8  OC48 LR 1550 Card Specifications

The OC48 LR 1550 card has the following specifications:

Line

Bit rate: 2.49 Gbps

Code: Scrambled NRZ

Fiber: 1550-nm single-mode

Loopback modes: Terminal and facility

Connectors: SC

Compliance: Telcordia GR-253-CORE

Transmitter

Maximum transmitter output power: +3 dBm

Minimum transmitter output power: -2 dBm

Center wavelength: 1520 to 1580 nm

Nominal wavelength: 1550 nm

Transmitter: DFB laser

Receiver

Maximum receiver level: -8 dBm

Minimum receiver level: -28 dBm

Receiver: InGaAs avalanche photo diode (APD) photodetector

Link loss budget: 26 dB minimum, with 1 dB dispersion penalty

Receiver input wavelength range: 1520 to 1580 nm

Environmental

Operating temperature:

C-Temp (15454-OC481LR1550): +23 to +131 degrees Fahrenheit (-5 to +55 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Weight not including clam shell: 1.8 lb (0.8 kg)

A.6.9  OC48 IR/STM16 SH AS 1310 Card Specifications

The OC48 IR/STM16 SH AS 1310 card has the following specifications:

Line

Bit rate: 2.49 Gbps

Code: Scrambled NRZ

Fiber: 1310-nm single-mode

Loopback modes: Terminal and facility

Connectors: SC

Compliance: Telcordia GR-253-CORE, ITU-T G.707, ITU-T G.957

Transmitter

Maximum transmitter output power: 0 dBm

Minimum transmitter output power: -5 dBm

Center wavelength: 1280 to 1350 nm

Nominal wavelength: 1310 nm

Transmitter: DFB laser

Dispersion tolerance: 96 ps/nm

Receiver

Maximum receiver level: 0 dBm

Minimum receiver level: -18 dBm

Receiver: InGaAs InP photodetector

Link loss budget: 13 dB minimum

Receiver input wavelength range: 1280 to 1350 nm

Jitter tolerance: Telcordia GR-253/ITU-T G.823 compliant

Environmental

Operating temperature:

C-Temp (15454-OC481IR1310A): +23 to +131 degrees Fahrenheit (-5 to +55 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Weight not including clam shell: 2.2 lb (0.9 kg)

A.6.10  OC48 LR/STM16 LH AS 1550 Card Specifications

The OC48 LR/STM16 SH AS 1550 card has the following specifications:

Line

Bit rate: 2.49 Gbps

Code: Scrambled NRZ

Fiber: 1550-nm single-mode

Loopback modes: Terminal and facility

Connectors: SC

Compliance: Telcordia GR-253-CORE, ITU-T G.707, ITU-T G.957

Transmitter

Maximum transmitter output power: +3 dBm

Minimum transmitter output power: -2 dBm

Center wavelength: 1520 to 1580 nm

Nominal wavelength: 1550 nm

Transmitter: DFB laser

Dispersion ratio: 3600 ps/nm

Receiver

Maximum receiver level: -8 dBm

Minimum receiver level: -28 dBm

Receiver: InGaAs APD photodetector

Link loss budget: 26 dB minimum, with 1 dB dispersion penalty

Receiver input wavelength range: 1520 to 1580 nm

Jitter tolerance: Telcordia GR-253/ITU-T G.823 compliant

Environmental

Operating temperature:

C-Temp (15454-OC481LR1550A): +23 to +131 degrees Fahrenheit (-5 to +55 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Weight not including clam shell: 2.2 lb (0.9 kg)

A.6.11  OC48 ELR/STM 16 EH 100 GHz Card Specifications

The OC48 ELR 100 GHz card has the following specifications:

Line

Bit rate: 2.49 Gbps

Code: Scrambled NRZ

Fiber: 1550-nm single-mode

Loopback modes: Terminal and facility

Connectors: SC

Compliance: Telcordia GR-253-CORE, ITU-T G.692, ITU-T G.958

Transmitter

Maximum transmitter output power: 0 dBm

Minimum transmitter output power: -2 dBm

Center wavelength accuracy: +/- 0.12 nm

Transmitter: Electro-absorption laser

Dispersion tolerance: 5400 ps/nm

Receiver

Maximum receiver level: -9 dBm

Minimum receiver level: -27 dBm at 1E-12 BER

Receiver: InGaAs APD photodetector

Link loss budget: 25 dB minimum at 1E-12 BER (not including the power dispersion penalty)

Dispersion penalty: 2 dB for a dispersion of up to 5400 ps/nm

Receiver input wavelength range: 1520 to 1580 nm

Jitter tolerance: Telcordia GR-253/ITU-T G.823 compliant

Environmental

Operating temperature: C-Temp: +23 to +131 degrees Fahrenheit (-5 to +55 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Weight not including clam shell: 2.4 lb (1.1 kg)

A.6.12  OC48 ELR 200 GHz Card Specifications

The OC48 ELR 200 GHz card has the following specifications:

Line

Bit rate: 2.49 Gbps

Code: Scrambled NRZ

Fiber: 1550-nm single-mode

Loopback modes: Terminal and facility

Connectors: SC

Compliance: Telcordia GR-253-CORE, ITU-T G692, ITU-T G958

Transmitter

Maximum transmitter output power: 0 dBm

Minimum transmitter output power: -2 dBm

Center wavelength accuracy: +/- 0.25 nm

Transmitter: Electro-absorption laser

Dispersion tolerance: 3600 ps/nm

Receiver

Maximum receiver level: -8 dBm

Minimum receiver level: -28 dBm

Receiver: InGaAs APD photodetector

Link loss budget: 26 dB minimum, with 1 dB dispersion penalty

Receiver input wavelength range: 1520 to 1580 nm

Jitter tolerance: Telcordia GR-253/ITU-T G.823 compliant

Environmental

Operating temperature:

C-Temp: +23 to +131 degrees Fahrenheit (-5 to +55 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Weight not including clam shell: 2.9 lb (1.3 kg)

A.6.13  OC192 SR/STM64 IO 1310 Card Specifications

The OC192 SR/STM64 IO 1310 card has the following specifications:

Line

Bit rate: 9.95328 Gbps

Code: Scrambled NRZ

Fiber: 1310-nm single-mode

Maximum chromatic dispersion allowance: 6.6 ps/nm

Loopback modes: Terminal and facility

Connectors: SC

Compliance: Telcordia GR-253-CORE, ITU-T G.707, ITU-T G.957, ITU-T G.691

Transmitter

Maximum transmitter output power: -1 dBm

Minimum transmitter output power: -6 dBm

Center wavelength: 1290 to 1330 nm

Nominal wavelength: 1310 nm

Transmitter: Directly modulated laser

Receiver

Maximum receiver level: -1 dBm at BER 1 * 10 exp - 12

Minimum receiver level: -11 dBm at BER 1 * 10 exp - 12

Receiver: PIN diode

Link loss budget: 5 dB minimum, plus 1 dB dispersion penalty
at BER = 1 * 10 exp - 12 including dispersion

Receiver input wavelength range: 1290 to 1330 nm

Dispersion tolerance: 6.6 ps/nm

Environmental

Operating temperature: +23 to +131 degrees Fahrenheit (-5 to +55 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Depth with backplane connector: 9.250 in. (235 mm)

Weight not including clam shell: 3.1 lb (1.3 kg)

A.6.14  OC192 IR/STM64 SH 1550 Card Specifications

The OC192 IR/STM64 SH 1550 card has the following specifications:

Line

Bit rate: 9.95328 Gbps

Code: Scrambled NRZ

Fiber: 1550-nm single-mode

Maximum chromatic dispersion allowance: 800 ps/nm

Loopback modes: Terminal and facility


Note You must use a 3 to 15 dB fiber attenuator (5 dB recommended) when working with the OC192 IR/STM64 SH 1550 card in a loopback. Do not use fiber loopbacks with the OC192 IR/STM64 SH 1550 card. Using fiber loopbacks can cause irreparable damage to the OC192 IR/STM64 SH 1550 card.


Connectors: SC

Compliance: Telcordia GR-253-CORE, ITU-T G.707, ITU-T G.957, ITU-T G.691

Transmitter

Maximum transmitter output power: +2 dBm

Minimum transmitter output power: -1 dBm

Center wavelength: 1530 to 1565 nm

Nominal wavelength: 1550 nm

Transmitter: Cooled EA (European accreditation) modulated laser

Receiver

Maximum receiver level: -1 dBm at BER 1 * 10 exp - 12

Minimum receiver level: -14 dBm at BER 1 * 10 exp - 12

Receiver: PIN diode

Link loss budget: 13 dB minimum, plus 2 dB dispersion penalty
at BER = 1 * 10 exp - 12 including dispersion

Receiver input wavelength range: 1530 to 1565 nm

Dispersion tolerance: 800 ps/nm

Environmental

Operating temperature: +23 to +131 degrees Fahrenheit (-5 to +55 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Depth with backplane connector: 9.250 in. (235 mm)

Weight not including clam shell: 3.1 lb (1.3 kg)

A.6.15  OC192 LR/STM64 LH 1550 Card Specifications

The OC192 LR/STM64 LH 1550 card has the following specifications:

Line

Bit rate: 9.95328 Gbps

Code: Scrambled NRZ

Fiber: 1550-nm single-mode

Loopback modes: Terminal and facility


Note You must use a fiber attenuator when connecting a fiber loopback to an OC192 LR/STM64 LH 1550 card. Use a 19 to 24 dB attenuator for 15454-OC192LR1550 or a 14 to 28 dB attenuator for 15454-OC192-LR2 (20 dB is recommended). Never connect a direct fiber loopback.


Connectors: SC

Compliance: Telcordia GR-253-CORE, ITU-T G.707, ITU-T G.957

Transmitter

Maximum transmitter output power:
+10 dBm (15454-OC192LR1550);
+7 dBm (15454-OC192-LR2)

Minimum transmitter output power:
+7 dBm (15454-OC192LR1550);
+4 dBm (15454-OC192-LR2)

Center wavelength: 1530 to 1565 nm

Nominal wavelength: 1550 nm

Maximum chromatic dispersion allowed: 1600 ps/nm

Transmitter: LN (Lithium Niobate) external modulator transmitter

Receiver

Maximum receiver level:
-10 dBm (15454-OC192LR1550);
-7 dBm (15454-OC192LR1550)

Minimum receiver level:
-19 dBm (15454-OC192LR1550);
-24 dBm from 1530 to 1565 nm
-20 dBm from 1290 to 1330 nm (15454-OC192-LR2)

Receiver: APD/TIA

Link loss budget: 24 dB minimum, with no dispersion or 22 dB optical path loss at BER = 1 - exp (-12) including dispersion

Receiver input wavelength range: 1530 to 1565 nm

Jitter tolerance: Telcordia GR-253/ITU-T G.823 compliant

Environmental

Operating temperature:

C-Temp (15454-OC192LR1550): +23 to +131 degrees Fahrenheit (-5 to +55 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Weight not including clam shell: 3.1 lb (1.3 kg)

A.6.16  OC192 LR/STM64 LH ITU 15xx.xx Card Specifications

The OC192 LR/STM64 LH ITU 15xx.xx card has the following specifications:

Line

Bit rate: 9.95328 Gbps

Code: Scrambled NRZ

Fiber: 1550-nm single-mode

Maximum chromatic dispersion allowance:

In deployments with a dispersion compensation unit (DCU): +/- 1000 ps/nm, with optical signal-to-noise ration (OSNR) of 19 dB (0.5 nm resolution bandwidth [RBW])

In deployments without a DCU: +/- 1200 ps/nm, with OSNR of 23 dB (0.5 nm RBW)

Loopback modes: Terminal and facility


Note You must use a 20-dB fiber attenuator (15 to 25 dB) when working with the OC192 LR/STM64 LH 15xx.xx card in a loopback. Do not use fiber loopbacks with the OC192 LR/STM64 LH 15xx.xx card. Using fiber loopbacks causes irreparable damage to this card.


Connectors: SC

Compliance: Telcordia GR-253-CORE, ITU-T G.707, ITU-T G.691, ITU-T G.957

Transmitter

Maximum transmitter output power: +6 dBm

Minimum transmitter output power: +3 dBm

Center wavelength: See wavelength plan

Center wavelength accuracy: +/- 0.040 nm

Transmitter: LN external modulator transmitter

Receiver

Maximum receiver level: -8 dBm at BER 1 * 10 exp - 12

Minimum receiver level: -22 dBm at BER 1 * 10 exp - 12

Receiver: APD

Link loss budget: 25 dB minimum, plus 2 dB dispersion penalty
at BER = 1 * 10 exp - 12 including dispersion

Receiver input wavelength range: 1529 to 1565 nm

Environmental

Operating temperature: +23 to +131 degrees Fahrenheit (-5 to +55 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Depth with backplane connector: 9.250 in. (235 mm)

Weight not including clam shell: 3.1 lb (1.3 kg)

Currently available wavelengths and versions of OC192 LR/STM64 LH ITU 15xx.xx card:

ITU grid blue band:

1534.25 +/- 0.040 nm, OC192 LR/STM64 LH ITU 1534.25

1535.04 +/- 0.040 nm, OC192 LR/STM64 LH ITU 1535.04

1535.82 +/- 0.040 nm, OC192 LR/STM64 LH ITU 1535.82

1536.61 +/- 0.040 nm, OC192 LR/STM64 LH ITU 1536.61

1538.19 +/- 0.040 nm, OC192 LR/STM64 LH ITU 1538.19

1538.98 +/- 0.040 nm, OC192 LR/STM64 LH ITU 1538.98

1539.77 +/- 0.040 nm, OC192 LR/STM64 LH ITU 1539.77

1540.56 +/- 0.040 nm, OC192 LR/STM64 LH ITU 1540.56

ITU grid red band:

1550.12 +/- 0.040 nm, OC192 LR/STM64 LH ITU 1550.12

1550.92 +/- 0.040 nm, OC192 LR/STM64 LH ITU 1550.92

1551.72 +/- 0.040 nm, OC192 LR/STM64 LH ITU 1551.72

1552.52 +/- 0.040 nm, OC192 LR/STM64 LH ITU 1552.52

1554.13 +/- 0.040 nm, OC192 LR/STM64 LH ITU 1554.13

1554.94 +/- 0.040 nm, OC192 LR/STM64 LH ITU 1554.94

1555.75 +/- 0.040 nm, OC192 LR/STM64 LH ITU 1555.75

1556.55 +/- 0.040 nm, OC192 LR/STM64 LH ITU 1556.55

A.6.17  15454_MRC-12 Card Specifications

The 15454_MRC-12 card has the following specifications:

Line

Bit rate: up to OC-48 (2488.320 Mbps), depending on SFP


Note Each optical interface on the card can be configured as OC-3, OC-12, or OC-48, depending on the available backplane bandwidth and existing provisioned lines. In general, the card supports all different rates on the line side as long as the accumulated bandwidth does not exceed the total backplane allowed bandwidth.


Fiber: 1550-nm single-mode

Connectors: LC duplex connector for each SFP

Compliance: Telcordia GR-253-CORE

Transmitter

Maximum transmitter output power: Depends on SFP (see SFP, XFP, and GBIC Specifications)

Minimum transmitter output power: Depends on SFP (see SFP, XFP, and GBIC Specifications)

Center wavelength: See wavelength plan

Center wavelength accuracy: 1 nm to 4 nm, depending on SFP

Transmitter: FP and DFB laser

Receiver

Maximum receiver level: Depends on SFP (see SFP, XFP, and GBIC Specifications)

Minimum receiver level: Depends on SFP (see SFP, XFP, and GBIC Specifications)

Receiver: PIN PD

Receiver input wavelength range: Depends on SFP

Environmental

Operating temperature: -40 to +149 degrees Fahrenheit (-40 to +65 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Depth with backplane connector: 9.250 in. (235 mm)

Weight not including clam shell: 3.1 lb (1.3 kg)

Wavelength plan. Currently available wavelengths and versions of the 15454_MRC-12 card:

For ONS-SC-2G-30.3 through ONS-SC-2G-60.0 SFPs: 1530.33 nm to 1560.61 nm
(32 distinct wavelengths at 100 GHz spacing)

For ONS-SE-622-1470 through ONS-SE-622-1610 SFPs: 1470 to 1610 nm
(eight distinct wavelengths at 2500 GHz spacing)

For ONS_SE-155-1470 through ONS-SE-155-1610 SFPs: 1470 to 1610 nm
(eight distinct wavelengths at 2500 GHz spacing)

A.6.18  OC192SR1/STM64IO Short Reach Card Specifications


Note The OC192SR1/STM64IO Short Reach card is designated as OC192-XFP in CTC.


The OC192SR1/STM64IO Short Reach card has the following specifications:

Line

Bit rate: OC-192 (9.9520 Gbps)

Fiber: 1310-nm single-mode

Connectors: LC duplex connector for the XFP

Compliance: Telcordia GR-253-CORE

Transmitter

Maximum transmitter output power: -1 dBm

Minimum transmitter output power: -6 dBm

Receiver

Maximum receiver level: -1 dBm

Minimum receiver level: -11 dBm

Receiver input wavelength range: 1260 to 1565 nm

Environmental

Operating temperature: 32 to +131 degrees Fahrenheit (0 to +55 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Depth with backplane connector: 9.250 in. (235 mm)

Weight not including clam shell: 3.1 lb (1.3 kg)

A.6.19  OC192/STM64 Any Reach Card Specifications


Note The OC192/STM64 Any Reach card is designated as OC192-XFP in CTC.


The OC192/STM64 Any Reach card has the following specifications:

Line

Bit rate: OC-192 (9.9520 Gbps)

Fiber: 1310-nm single-mode for ONS-XC-10G-S1 XFP, 1550-nm single mode for ONS-XC-10G-I2 and ONS-XC-10G-L2 XFPs

Connectors: LC duplex connector for the XFPs

Compliance: Telcordia GR-253-CORE

Transmitter

Maximum transmitter output power: Depends on SFP (see SFP, XFP, and GBIC Specifications)

Minimum transmitter output power: Depends on SFP (see SFP, XFP, and GBIC Specifications)

Receiver

Maximum receiver level: Depends on SFP (see SFP, XFP, and GBIC Specifications)

Minimum receiver level: Depends on SFP (see SFP, XFP, and GBIC Specifications)

Receiver input wavelength range: 1260 to 1565 nm

Environmental

Operating temperature: 32 to +131 degrees Fahrenheit (0 to +55 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Depth with backplane connector: 9.250 in. (235 mm)

Weight not including clam shell: 3.1 lb (1.3 kg)

A.7  Ethernet Card Specifications

This section includes specifications for the E100T-12, E100T-G, E1000-2, E1000-2-G, CE-1000-4, CE-100T-8, G1K-4, ML100T-12, ML1000-2, and ML100X-8 cards.

For compliance information, refer to the Cisco Optical Transport Products Safety and Compliance Information document.

A.7.1  E100T-12 Card Specifications

The E100T-12 card has the following specifications:

Environmental

Operating temperature

C-Temp (15454-E100T): 32 to 131 degrees Fahrenheit (0 to +55 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Card weight: 2.3 lb (1.0 kg)

A.7.2  E100T-G Card Specifications

The E100T-G card has the following specifications:

Environmental

Operating temperature:

C-Temp (15454-E100T-G): 32 to 131 degrees Fahrenheit (0 to +55 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Card weight: 2.3 lb (1.0 kg)

A.7.3  E1000-2 Card Specifications

The E1000-2 card has the following specifications:

Environmental

Operating temperature:

C-Temp (15454-E1000-2): 32 to 131 degrees Fahrenheit (0 to +55 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Card weight: 2.1 lb (0.9 kg)

A.7.4  E1000-2-G Card Specifications

The E1000-2-G card has the following specifications:

Environmental

Operating temperature:

C-Temp (15454-E1000-2-G): 32 to 131 degrees Fahrenheit (0 to +55 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Card weight: 2.1 lb (0.9 kg)

A.7.5  CE-1000-4 Card Specifications

The CE-1000-4 card has the following specifications:

Environmental

Operating temperature: +23 to +131 degrees Fahrenheit (-5 to +55 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Dimensions

Height: 12.650 in. (321.310 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Card weight: 2.1 lb (0.9 kg)

A.7.6  CE-100T-8 Card Specifications

The CE-100T-8 card has the following specifications:

Environmental

Operating temperature

C-Temp (15454-CE100T): 32 to 131 degrees Fahrenheit (0 to +55 degrees Celsius)

Operating humidity: 0 to 95 percent, noncondensing

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.913 in. (23.19 mm)

Depth: 9.073 in. (230.45 mm)

Card weight: 1.8 lb (0.82 kg)

A.7.7  G1K-4 Card Specifications

The G1K-4 card has the following specifications:

Environmental

Operating temperature: +23 to +131 degrees Fahrenheit (-5 to +55 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Depth with backplane connector: 9.250 in. (235 mm)

Weight not including clam shell: 2.1 lb (0.9 kg)

A.7.8  ML100T-12 Card Specifications

The ML100T-12 card has the following specifications:

Environmental

Operating temperature: +23 to +131 degrees Fahrenheit (-5 to +55 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Depth with backplane connector: 9.250 in. (235 mm)

Weight not including clam shell: 2.3 lb (1.0 kg)

A.7.9  ML1000-2 Card Specifications

The ML1000-2 card has the following specifications:

Environmental

Operating temperature: +23 to +131 degrees Fahrenheit (-5 to +55 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Depth with backplane connector: 9.250 in. (235 mm)

Weight not including clam shell: 0.9 kg (2.1 lb)

A.7.10  ML100X-8 Card Specifications

The ML100X-8 card has the following specifications:

Environmental

Operating temperature: +23 to +131 degrees Fahrenheit (-5 to +55 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Depth with backplane connector: 9.250 in. (235 mm)

Weight not including clam shell: 0.9 kg (2.1 lb)

A.8  Storage Access Networking Card Specifications

This section describes the FC_MR-4 (Fibre Channel) card specifications.

For compliance information, refer to the Cisco Optical Transport Products Safety and Compliance Information document.

A.8.1  FC_MR-4 Card Specifications

The FC_MR-4 card has the following specifications:

Fibre Channel Support: FC-0 and FC-1 layers of ANSI X3.230 FC-PH

GBIC Line Interface

Bit Rate: 1.0625 Gbit/s single-rate or 1.0625/2.125 dual-rate Gbit/s Fibre Channel (FC)

Wavelength/Fiber/Reach:

850 nm, multimode fiber, 550 m (SX)

1310 nm, single-mode fiber, 10 km (LX)

1550 nm/, single-mode fiber, 80 km (ZX)

Hot pluggable

Auto-detection

Transmitter

Maximum transmitter output power: depends on GBIC type (see Table A-1)

Minimum transmitter output power: depends on GBIC type (see Table A-1)

Receiver

Maximum receiver level: depends on GBIC type (see Table A-1)

Minimum receiver level: depends on GBIC type (see Table A-1)

Environmental

Operating temperature

C-Temp (15454-E100T): 23 to 131 degrees Fahrenheit (-5 to +55 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Card weight: 2.59 lb (1.17 kg)


hometocprevnextglossaryfeedbacksearchhelp

Posted: Wed Nov 21 00:42:03 PST 2007
All contents are Copyright © 1992--2007 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.