cc/td/doc/product/ong/15400/r70docs
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table Of Contents

Performance Monitoring

15.1  Threshold Performance Monitoring

15.2  Intermediate Path Performance Monitoring

15.3  Pointer Justification Count Performance Monitoring

15.4  Performance Monitoring Parameter Definitions

15.5  Performance Monitoring for Electrical Cards

15.5.1  EC1-12 Card Performance Monitoring Parameters

15.5.2  DS1_E1_56 Card Performance Monitoring Parameters

15.5.3  DS1-14 and DS1N-14 Card Performance Monitoring Parameters

15.5.4  DS3-12 and DS3N-12 Card Performance Monitoring Parameters

15.5.5  DS3-12E and DS3N-12E Card Performance Monitoring Parameters

15.5.6  DS3i-N-12 Card Performance Monitoring Parameters

15.5.7  DS3XM-6 Card Performance Monitoring Parameters

15.5.8  DS3XM-12 Card Performance Monitoring Parameters

15.5.9  DS3-EC1-48 Card Performance Monitoring Parameters

15.6  Performance Monitoring for Ethernet Cards

15.6.1  E-Series Ethernet Card Performance Monitoring Parameters

15.6.2  G-Series Ethernet Card Performance Monitoring Parameters

15.6.3  ML-Series Ethernet Card Performance Monitoring Parameters

15.6.4  CE-Series Ethernet Card Performance Monitoring Parameters

15.7  Performance Monitoring for Optical Cards

15.8  Performance Monitoring for Optical Multirate Cards

15.9  Performance Monitoring for Storage Access Networking Cards

15.9.1  FC_MR-4 Statistics Window

15.9.2  FC_MR-4 Utilization Window

15.9.3  FC_MR-4 History Window


Performance Monitoring


Performance monitoring (PM) parameters are used by service providers to gather, store, set thresholds for, and report performance data for early detection of problems. In this chapter, PM parameters and concepts are defined for electrical cards, Ethernet cards, optical cards, optical multirate cards, and storage access networking (SAN) cards in the Cisco ONS 15454.

For information about enabling and viewing PM values, refer to the Cisco ONS 15454 Procedure Guide.

Chapter topics include:

Threshold Performance Monitoring

Intermediate Path Performance Monitoring

Pointer Justification Count Performance Monitoring

Performance Monitoring Parameter Definitions

Performance Monitoring for Electrical Cards

Performance Monitoring for Ethernet Cards

Performance Monitoring for Optical Cards

Performance Monitoring for Optical Multirate Cards

Performance Monitoring for Storage Access Networking Cards


Note For information on PM parameters for Transponder and Muxponder cards, and DWDM cards, refer to Cisco ONS 15454 DWDM Reference Manual.



Note For additional information regarding PM parameters, refer to Telcordia documents GR-1230-CORE, GR-820-CORE, GR-499-CORE, and GR-253-CORE and the ANSI T1.231 document entitled Digital Hierarchy - Layer 1 In-Service Digital Transmission Performance Monitoring.


15.1  Threshold Performance Monitoring

Thresholds are used to set error levels for each PM parameter. You can set individual PM threshold values from the Cisco Transport Controller (CTC) card view Provisioning tab. For procedures on provisioning card thresholds, such as line, path, and SONET thresholds, refer to the Cisco ONS 15454 Procedure Guide.

During the accumulation cycle, if the current value of a PM parameter reaches or exceeds its corresponding threshold value, a threshold crossing alert (TCA) is generated by the node and displayed by CTC. TCAs provide early detection of performance degradation. When a threshold is crossed, the node continues to count the errors during a given accumulation period. If zero is entered as the threshold value, generation of TCAs is disabled, but performance monitoring continues.

When TCAs occur, CTC displays them. An example is T-UASP-P in the Cond column (shown in Figure 15-1), where the "T-" indicates a threshold crossing. In addition, for certain electrical cards, "RX" or "TX" is appended to the TCA description, as shown (see red circles). The RX indicates that the TCA is associated with the receive direction, and TX indicates the TCA is associated with the transmit direction.

Figure 15-1 TCAs Displayed in CTC

The ONS 15454 SONET electrical cards for which RX and TX are detected and appended to the TCA descriptions are shown in Table 15-1.

Table 15-1 Electrical Cards that Report RX and TX Direction for TCAs

Card
Line
Path
 
Near End
Far End
Near End
Far End
RX
TX
RX
TX
RX
TX
RX
TX

DS1-14

YES

YES

YES

YES

YES

DS1N-14

YES

YES

YES

YES

YES



Note Due to limitations of memory and the number of TCAs generated by different platforms, you can manually add/modify the following two properties to the platform property file (CTC.INI for Windows and .ctcrc for UNIX) to fit the need:ctc.15xxx.node.tr.lowater=yyy (where xxx is platform and yyy is the number of the lowater mark. The default lowater mark is 25.)
ctc.15xxx.node.tr.hiwater=yyy (where xxx is platform and yyy is the number of the hiwater mark. The default hiwater mark is 50.)
If the number of the incoming TCA is greater than the hiwater mark, it will keep the latest lowater mark and discard older ones.


Change the threshold if the default value does not satisfy your error monitoring needs. For example, customers with a critical DS-1 installed for 911 calls must guarantee the best quality of service on the line; therefore, they lower all thresholds so that the slightest error raises a TCA.

15.2  Intermediate Path Performance Monitoring

Intermediate path performance monitoring (IPPM) allows transparent monitoring of a constituent channel of an incoming transmission signal by a node that does not terminate that channel. Many large networks only use line terminating equipment (LTE), not path terminating equipment (PTE). Table 15-2 shows ONS 15454 cards that are considered LTE.

Table 15-2 ONS 15454 Line Terminating Equipment 

ONS 15454 Electrical LTE

EC1-12 card

ONS 15454 Optical LTE

OC3 IR 4/STM1 SH 1310

OC3 IR/STM1 SH 1310-8

OC12 IR/STM4 SH1310

OC12 LR/STM4 LH1310

OC12 LR/STM4 LH 1550

OC12 IR/STM4 SH 1310-4

OC48 IR 13101

OC48 LR 1550

OC48 IR/STM16 SH AS 1310 1

OC48 LR/STM16 LH AS 1550

OC48 ELR/STM16 EH 100 GHz

OC48 ELR 200 GHz

OC192 SR/STM64 IO 1310

OC192 IR/STM64 SH 1550

OC192 LR/STM64 LH 1550

OC192 LR/STM64 LH ITU 15xx.xx

TXP_MR_10G

MXP_2.5G_10G

MXP_MR_2.5G

MXPP_MR_2.5G

1 An OC-48 IR card used in a bidirectional line switched ring (BLSR) does not support IPPM during a protection switch.


ONS 15454 Software R3.0 and higher allows LTE cards to monitor near-end PM data on individual synchronous transport signal (STS) payloads by enabling IPPM. After enabling IPPM provisioning on the line card, service providers can monitor large amounts of STS traffic through intermediate nodes, thus making troubleshooting and maintenance activities more efficient.

IPPM occurs only on STS paths that have IPPM enabled, and TCAs are raised only for PM parameters on the IPPM enabled paths. The monitored IPPM parameters are STS CV-P, STS ES-P, STS SES-P, STS UAS-P, and STS FC-P.


Note Far-end IPPM is not supported by all OC-N cards. It is supported by OC3-4 and EC-1 cards. However, SONET path PMs can be monitored by logging into the far-end node directly.


The ONS 15454 performs IPPM by examining the overhead in the monitored path and by reading all of the near-end path PM values in the incoming direction of transmission. The IPPM process allows the path signal to pass bidirectionally through the node completely unaltered.

See Table 15-3 for detailed information and definitions of specific IPPM parameters.

15.3  Pointer Justification Count Performance Monitoring

Pointers are used to compensate for frequency and phase variations. Pointer justification counts indicate timing errors on SONET networks. When a network is out of synchronization, jitter and wander occur on the transported signal. Excessive wander can cause terminating equipment to slip.

Slips cause different effects in service. Voice service has intermittent audible clicks. Compressed voice technology has short transmission errors or dropped calls. Fax machines lose scanned lines or experience dropped calls. Digital video transmission has distorted pictures or frozen frames. Encryption service loses the encryption key, causing data to be transmitted again.

Pointers provide a way to align the phase variations in STS and VT payloads. The STS payload pointer is located in the H1 and H2 bytes of the line overhead. Clocking differences are measured by the offset in bytes from the pointer to the first byte of the STS synchronous payload envelope (SPE) called the J1 byte. Clocking differences that exceed the normal range of 0 to 782 can cause data loss.

There are positive (PPJC) and negative (NPJC) pointer justification count parameters. PPJC is a count of path-detected (PPJC-PDET-P) or path-generated (PPJC-PGEN-P) positive pointer justifications. NPJC is a count of path-detected (NPJC-PDET-P) or path-generated (NPJC-PGEN-P) negative pointer justifications depending on the specific PM name. PJCDIFF is the absolute value of the difference between the total number of detected pointer justification counts and the total number of generated pointer justification counts. PJCS-PDET-P is a count of the one-second intervals containing one or more PPJC-PDET or NPJC-PDET. PJCS-PGEN-P is a count of the one-second intervals containing one or more PPJC-PGEN or NPJC-PGEN.

A consistent pointer justification count indicates clock synchronization problems between nodes. A difference between the counts means that the node transmitting the original pointer justification has timing variations with the node detecting and transmitting this count. Positive pointer adjustments occur when the frame rate of the SPE is too slow in relation to the rate of the STS-1.

You must enable PPJC and NPJC performance monitoring parameters for LTE cards. See Table 15-2 for a list of Cisco ONS 15454 LTE cards. In CTC, the count fields for PPJC and NPJC PMs appear white and blank unless they are enabled on the card view Provisioning tab.

See Table 15-3 for detailed information and definitions of specific pointer justification count PM parameters.

15.4  Performance Monitoring Parameter Definitions

Table 15-3 gives definitions for each type of PM parameter found in this chapter.

Table 15-3 Performance Monitoring Parameters 

Parameter
Definition

AISS-P

AIS Seconds Path (AISS-P) is a count of one-second intervals containing one or more alarm indication signal (AIS) defects.

BBE-PM

Path Monitoring Background Block Errors (BBE-PM) indicates the number of background block errors recorded in the optical transport network (OTN) path during the PM time interval.

BBE-SM

Section Monitoring Background Block Errors (BBE-SM) indicates the number of background block errors recorded in the OTN section during the PM time interval.

BBER-PM

Path Monitoring Background Block Errors Ratio (BBER-PM) indicates the background block errors ratio recorded in the OTN path during the PM time interval.

BBER-SM

Section Monitoring Background Block Errors Ratio (BBER-SM) indicates the background block errors ratio recorded in the OTN section during the PM time interval.

BIEC

Bit Errors Corrected (BIEC) indicated the number of bit errors corrected in the DWDM trunk line during the PM time interval.

CSS

Controlled Slip Seconds (CSS) indicates the count of the seconds when at least one or more controlled slips have occurred.

CSS-P

Controlled Slip Seconds Path (CSS-P) indicates the count of the seconds when at least one or more controlled slips have occurred.

CVCP-P

Code Violation CP-bit Path (CVCP-P) is a count of CP-bit parity errors occurring in the accumulation period.

CVCP-PFE

Code Violation CP-bit Path (CVCP-PFE) is a parameter that is counted when the three far-end block error (FEBE) bits in an M-frame are not all collectively set to 1.

CGV

Code Group Violations (CGV) is a count of received code groups that do not contain a start or end delimiter.

CV-L

Line Code Violation (CV-L) indicates the number of coding violations occurring on the line. This parameter is a count of bipolar violations (BPVs) and excessive zeros (EXZs) occurring over the accumulation period.

CV-P

Near-End STS Path Coding Violations (CV-P) is a count of BIP errors detected at the STS path layer (that is, using the B3 byte). Up to eight BIP errors can be detected per frame; each error increments the current CV-P second register.

CV-PFE

Far-End STS Path Coding Violations (CV-PFE) is a count of BIP errors detected at the STS path layer (that is, using the B3 byte). Up to eight BIP errors can be detected per frame; each error increments the current CV-PFE second register.

CVP-P

Code Violation Path (CVP-P) is a code violation parameter for M23 applications. CVP-P is a count of P-bit parity errors occurring in the accumulation period.

CV-S

Section Coding Violation (CV-S) is a count of bit interleaved parity (BIP) errors detected at the section layer (that is, using the B1 byte in the incoming SONET signal). Up to eight section BIP errors can be detected per STS-N frame; each error increments the current CV-S second register.

CV-V

Code Violation VT Layer (CV-V) is a count of the BIP errors detected at the VT path layer. Up to two BIP errors can be detected per VT superframe, with each error incrementing the current CV-V second register.

DCG

Data Code Groups (DCG) is a count of received data code groups that do not contain ordered sets.

ESA-P

Path Errored Seconds-A (ESA-P) is the count of 1-second intervals with exactly one CRC-6 error and no AIS or severely errored framing (SEF) defects.

ESB-P

Path Errored Seconds-B (Rx ESB-P) is a count of 1-second intervals with between 2 and 319 CRC-6 errors and no AIS or SEF.

ESCP-P

Errored Seconds CP-bit Path (ESCP-P) is a count of seconds containing one or more CP-bit parity errors, one or more SEF defects, or one or more AIS defects. ESCP-P is defined for the C-bit parity application.

ESCP-PFE

Far-End Errored Seconds CP-bit Path (ESCP-PFE) is a count of one-second intervals containing one or more M-frames with the three FEBE bits not all collectively set to 1 or one or more far-end SEF/AIS defects.

ES-L

Line Errored Seconds (ES-L) is a count of the seconds containing one or more anomalies (BPV + EXZ) and/or defects (that is, loss of signal) on the line.

ES-NP

 

ES-P

Near-End STS Path Errored Seconds (ES-P) is a count of the seconds when at least one STS path BIP error was detected. An AIS Path (AIS-P) defect (or a lower-layer, traffic-related, near-end defect) or a Loss of Pointer Path (LOP-P) defect can also cause an ES-P.

ES-PFE

Far-End STS Path Errored Seconds (ES-PFE) is a count of the seconds when at least one STS path BIP error was detected. An AIS-P defect (or a lower-layer, traffic-related, far-end defect) or an LOP-P defect can also cause an STS ES-PFE.

ES-PM

Path Monitoring Errored Seconds (ES-PM) indicates the errored seconds recorded in the OTN path during the PM time interval.

ESP-P

Errored Seconds Path (ESP-P) is a count of seconds containing one or more P-bit parity errors, one or more SEF defects, or one or more AIS defects.

ESR-PM

Path Monitoring Errored Seconds Ratio (ESR-PM) indicates the errored seconds ratio recorded in the OTN path during the PM time interval.

ESR-SM

Section Monitoring Errored Seconds Ratio (ESR-SM) indicates the errored seconds ratio recorded in the OTN section during the PM time interval.

ES-S

Section Errored Seconds (ES-S) is a count of the number of seconds when at least one section-layer BIP error was detected or an SEF or loss of signal (LOS) defect was present.

ES-SM

Section Monitoring Errored Seconds (ES-SM) indicates the errored seconds recorded in the OTN section during the PM time interval.

ES-V

Errored Seconds VT Layer (ES-V) is a count of the seconds when at least one VT Path BIP error was detected. An AIS Virtual Tributary (VT) (AIS-V) defect (or a lower-layer, traffic-related, near-end defect) or an LOP VT (LOP-V) defect can also cause an ES-V.

FC-L

Line Failure Count (FC-L) is a count of the number of near-end line failure events. A failure event begins when an AIS Line (AIS-L) failure is declared or when a lower-layer, traffic-related, near-end failure is declared. This failure event ends when the failure is cleared. A failure event that begins in one period and ends in another period is counted only in the period where it begins.

FC-P

Near-End STS Path Failure Counts (FC-P) is a count of the number of near-end STS path failure events. A failure event begins when an AIS-P failure, an LOP-P failure, a UNEQ-P failure, or a Section Trace Identifier Mismatch Path (TIM-P) failure is declared. A failure event also begins if the STS PTE that is monitoring the path supports Three-Bit (Enhanced) Remote Failure Indication Path Connectivity (ERFI-P-CONN) for that path. The failure event ends when these failures are cleared.

FC-PFE

Far-End STS Path Failure Counts (FC-PFE) is a count of the number of near-end STS path failure events. A failure event begins when an AIS-P failure, an LOP-P failure, a UNEQ-P failure, or a TIM-P failure is declared. A failure event also begins if the STS PTE that is monitoring the path supports ERFI-P-CONN for that path. The failure event ends when these failures are cleared.

FC-PM

Path Monitoring Failure Counts (FC-PM) indicates the failure counts recorded in the OTN path during the PM time interval.

FC-SM

Section Monitoring Failure Counts (FC-SM) indicates the failure counts recorded in the OTN section during the PM time interval.

IOS

Idle Ordered Sets (IOS) is a count of received packets containing idle ordered sets.

IPC

Invalid Packets (IPC) is the count of received packets that contain errored data code groups that have start and end delimiters.

LBCL-MIN

Laser Bias Current Line—Minimum (LBCL-MIN) is the minimum percentage of laser bias current.

LBCL-AVG

Laser Bias Current Line—Average (LBCL-AVG) is the average percentage of laser bias current.

LBCL-MAX

Laser Bias Current Line—Maximum (LBCL-MAX) is the maximum percentage of laser bias current.

LOFC

Loss of Frame Count (LOFC)

LOSS-L

Line Loss of Signal (LOSS-L) is a count of one-second intervals containing one or more LOS defects.

NIOS

Non-Idle Ordered Sets (NIOS) is a count of received packets containing non-idle ordered sets.

NPJC-PDET

Negative Pointer Justification Count, STS Detected (NPJC-PDET), formerly Pointer Justification Negative (PJNEG)

NPJC-PDET-P

Negative Pointer Justification Count, STS Path Detected (NPJC-PDET-P) is a count of the negative pointer justifications detected on a particular path in an incoming SONET signal.

NPJC-PGEN-P

Negative Pointer Justification Count, STS Path Generated (NPJC-PGEN-P) is a count of the negative pointer justifications generated for a particular path to reconcile the frequency of the SPE with the local clock.

OPR

Optical Power Received (OPR) is the measure of average optical power received as a percentage of the nominal OPR.

OPR-AVG

Average Receive Optical Power (dBm)

OPR-MAX

Maximum Receive Optical Power (dBm)

OPR-MIN

Minimum Receive Optical Power (dBm)

OPT

Optical Power Transmitted (OPT) is the measure of average optical power transmitted as a percentage of the nominal OPT.

OPT-AVG

Average Transmit Optical Power (dBm)

OPT-MAX

Maximum Transmit Optical Power (dBm)

OPT-MIN

Minimum Transmit Optical Power (dBm)

OPWR-AVG

Optical Power - Average (OPWR-AVG) is the measure of average optical power on the unidirectional port.

OPWR-MAX

Optical Power - Maximum (OPWR-MAX) is the measure of maximum value of optical power on the unidirectional port.

OPWR-MIN

Optical Power - Minimum (OPWR-MIN) is the measure of minimum value of optical power on the unidirectional port.

PJCDIFF-P

Pointer Justification Count Difference, STS Path (PJCDIFF-P) is the absolute value of the difference between the total number of detected pointer justification counts and the total number of generated pointer justification counts. That is, PJCDiff-P is equal to (PPJC-PGEN-P - NPJC-PGEN-P) - (PPJC-PDET-P - NPJC-PDET-P).

PPJC-PDET

Pointer Justification STS Detected (PPJC-PDET), formerly Pointer Justification Positive (PJPOS).

PPJC-PDET-P

Positive Pointer Justification Count, STS Path Detected (PPJC-PDET-P) is a count of the positive pointer justifications detected on a particular path in an incoming SONET signal.

PPJC-PGEN-P

Positive Pointer Justification Count, STS Path Generated (PPJC-PGEN-P) is a count of the positive pointer justifications generated for a particular path to reconcile the frequency of the SPE with the local clock.

PJCS-PDET-P

Pointer Justification Count Seconds, STS Path Detect (NPJCS-PDET-P) is a count of the one-second intervals containing one or more PPJC-PDET or NPJC-PDET.

PJCS-PGEN-P

Pointer Justification Count Seconds, STS Path Generate (PJCS-PGEN-P) is a count of the one-second intervals containing one or more PPJC-PGEN or NPJC-PGEN.

PSC

In a 1 + 1 protection scheme for a working card, Protection Switching Count (PSC) is a count of the number of times service switches from a working card to a protection card plus the number of times service switches back to the working card.

For a protection card, PSC is a count of the number of times service switches to a working card from a protection card plus the number of times service switches back to the protection card. The PSC PM parameter is only applicable if revertive line-level protection switching is used.

PSC-R

In a four-fiber bidirectional line switched ring (BLSR), Protection Switching Count-Ring (PSC-R) is a count of the number of times service switches from a working line to a protection line plus the number of times it switches back to a working line. A count is only incremented if ring switching is used.

PSC-S

In a four-fiber BLSR, Protection Switching Count-Span (PSC-S) is a count of the number of times service switches from a working line to a protection line plus the number of times it switches back to the working line. A count is only incremented if span switching is used.

PSC-W

For a working line in a two-fiber BLSR, Protection Switching Count-Working (PSC-W) is a count of the number of times traffic switches away from the working capacity in the failed line and back to the working capacity after the failure is cleared. PSC-W increments on the failed working line and PSC increments on the active protect line.

For a working line in a four-fiber BLSR, PSC-W is a count of the number of times service switches from a working line to a protection line plus the number of times it switches back to the working line. PSC-W increments on the failed line and PSC-R or PSC-S increments on the active protect line.

PSD

Protection Switching Duration (PSD) applies to the length of time, in seconds, that service is carried on another line. For a working line, PSD is a count of the number of seconds that service was carried on the protection line.

For the protection line, PSD is a count of the seconds that the line was used to carry service. The PSD PM is only applicable if revertive line-level protection switching is used.

PSD-R

In a four-fiber BLSR, Protection Switching Duration-Ring (PSD-R) is a count of the seconds that the protection line was used to carry service. A count is only incremented if ring switching is used.

PSD-S

In a four-fiber BLSR, Protection Switching Duration-Span (PSD-S) is a count of the seconds that the protection line was used to carry service. A count is only incremented if span switching is used.

SASCP-P

SEF/AIS Seconds CP-bit Path (SASCP-P) is a count of one-second intervals containing one or more SEFs or one or more AIS defects on the path.

SASP

SEF/AIS Seconds (SASP) is a count of one-second intervals containing one or more SEFs or one or more AIS defects on the path.

SASP-P

SEF/AIS Seconds Path (SASP-P) is a count of one-second intervals containing one or more SEFs or one or more AIS defects on the path.

SEF-S

Severely Errored Framing Seconds (SEFS-S) is a count of the seconds when an SEF defect was present. An SEF defect is expected to be present during most seconds when an LOS or loss of frame (LOF) defect is present. However, there can be situations when the SEFS-S parameter is only incremented based on the presence of the SEF defect.

SESCP-P

Severely Errored Seconds CP-bit Path (SESCP-P) is a count of seconds containing more than 44 CP-bit parity errors, one or more SEF defects, or one or more AIS defects.

SESCP-PFE

Severely Errored Seconds CP-bit Path (SESCP-PFE) is a count of one-second intervals containing one or more far-end SEF/AIS defects, or one or more 44 M-frames with the three FEBE bits not all collectively set to 1.

SES-L

Line Severely Errored Seconds (SES-L) is a count of the seconds containing more than a particular quantity of anomalies (BPV + EXZ > 44) and/or defects on the line.

SES-P

Near-End STS Path Severely Errored Seconds (SES-P) is a count of the seconds when K (2400) or more STS path BIP errors were detected. An AIS-P defect (or a lower-layer, traffic-related, near-end defect) or an LOP-P defect can also cause an SES-P.

SES-PFE

Far-End STS Path Severely Errored Seconds (SES-PFE) is a count of the seconds when K (2400) or more STS path BIP errors were detected. An AIS-P defect (or a lower-layer, traffic-related, far-end defect) or an LOP-P defect can also cause an SES-PFE.

SES-PM

Path Monitoring Severely Errored Seconds (SES-PM) indicates the severely errored seconds recorded in the OTN path during the PM time interval.

SESP-P

Severely Errored Seconds Path (SESP-P) is a count of seconds containing more than 44 P-bit parity violations, one or more SEF defects, or one or more AIS defects.

SES-S

Section Severely Errored Seconds (SES-S) is a count of the seconds when K (see Telcordia GR-253 for value) or more section-layer BIP errors were detected or an SEF or LOS defect was present.

SES-SM

Section Monitoring Severely Errored Seconds (SES-SM) indicates the severely errored seconds recorded in the OTN section during the PM time interval.

SESR-PM

Path Monitoring Severely Errored Seconds Ratio (SESR-PM) indicates the severely errored seconds ratio recorded in the OTN path during the PM time interval.

SESR-SM

Section Monitoring Severely Errored Seconds Ratio (SESR-SM) indicates the severely errored seconds ratio recorded in the OTN section during the PM time interval.

SES-V

Severely Errored Seconds VT Layer (SES-V) is a count of seconds when K (600) or more VT Path BIP errors were detected. An AIS-V defect (or a lower-layer, traffic-related, near-end defect) or an LOP-V defect can also cause SES-V.

UAS-L

Line Unavailable Seconds (UAS-L) is a count of the seconds when the line is unavailable. A line becomes unavailable when ten consecutive seconds occur that qualify as SES-Ls, and it continues to be unavailable until ten consecutive seconds occur that do not qualify as SES-Ls.

UASCP-P

Unavailable Seconds CP-bit Path (UASCP-P) is a count of one-second intervals when the DS-3 path is unavailable. A DS-3 path becomes unavailable when ten consecutive SESCP-Ps occur. The ten SESCP-Ps are included in unavailable time. After the DS-3 path becomes unavailable, it becomes available again when ten consecutive seconds with no SESCP-Ps occur. The ten seconds with no SESCP-Ps are excluded from unavailable time.

UASCP-PFE

Unavailable Seconds CP-bit Path (UASCP-PFE) is a count of one-second intervals when the DS-3 path becomes unavailable. A DS-3 path becomes unavailable when ten consecutive far-end CP-bit SESs occur. The ten CP-bit SESs are included in unavailable time. After the DS-3 path becomes unavailable, it becomes available again when ten consecutive seconds occur with no CP-bit SESs. The ten seconds with no CP-bit SESs are excluded from unavailable time.

UAS-P

Near-End STS Path Unavailable Seconds (UAS-P) is a count of the seconds when the STS path was unavailable. An STS path becomes unavailable when ten consecutive seconds occur that qualify as SES-Ps, and continues to be unavailable until ten consecutive seconds occur that do not qualify as SES-Ps.

UAS-PFE

Far-End STS Path Unavailable Seconds (UAS-PFE) is a count of the seconds when the STS path was unavailable. An STS path becomes unavailable when ten consecutive seconds occur that qualify as SES-PFEs, and continues to be unavailable until ten consecutive seconds occur that do not qualify as SES-PFEs.

UAS-PM

Path Monitoring Unavailable Seconds (UAS-PM) indicates the unavailable seconds recorded in the OTN path during the PM time interval.

UASP-P

Unavailable Seconds Path (UASP-P) is a count of one-second intervals when the DS-3 path is unavailable. A DS-3 path becomes unavailable when ten consecutive SESP-Ps occur. The ten SESP-Ps are included in unavailable time. After the DS-3 path becomes unavailable, it becomes available again when ten consecutive seconds with no SESP-Ps occur. The ten seconds with no SESP-Ps are excluded from unavailable time.

UAS-SM

Section Monitoring Unavailable Seconds (UAS-SM) indicates the unavailable seconds recorded in the OTN section during the PM time interval.

UAS-V

Unavailable Seconds VT Layer (UAS-V) is a count of the seconds when the VT path was unavailable. A VT path becomes unavailable when ten consecutive seconds occur that qualify as SES-Vs, and it continues to be unavailable until ten consecutive seconds occur that do not qualify as SES-Vs.

UNC-WORDS

Uncorrectable Words (UNC-WORDS) is the number of uncorrectable words detected in the DWDM trunk line during the PM time interval.

VPC

Valid Packets (VPC) is a count of received packets that contain non-errored data code groups that have start and end delimiters.


15.5  Performance Monitoring for Electrical Cards

The following sections define PM parameters for the EC1-12, DS1/E1-56, DS1-14, DS1N-14, DS3-12, DS3-12E, DS3N-12, DS3N-12E, DS3i-N-12, DS3XM-6, DS3XM-12, and DS3/EC1-48 cards.

15.5.1  EC1-12 Card Performance Monitoring Parameters

Figure 15-2 shows signal types that support near-end and far-end PMs. Figure 15-3 shows where overhead bytes detected on the application specific integrated circuits (ASICs) produce PM parameters for the EC1-12 card.

Figure 15-2 Monitored Signal Types for the EC1-12 Card


Note The XX in Figure 15-2 represents all PMs listed in Table 15-4 with the given prefix and/or suffix.


Figure 15-3 PM Read Points on the EC1-12 Card

Table 15-4 lists the PM parameters for the EC1-12 cards.

Table 15-4 EC1-12 Card PMs 

Section (NE)
Line (NE)
STS Path (NE)
Line (FE)
STS Path (FE)

CV-S
ES-S
SES-S
SEF-S

CV-L
ES-L
SES-L
UAS-L
FC-L

CV-P
ES-P
SES-P
UAS-P
FC-P
PPJC-PDET-P
NPJC-PDET-P
PPJC-PGEN-P
NPJC-PGEN-P
PJCS-PDET-P
PJCS-PGEN-P
PJC-DIFF-P

CV-LFE
ES-LFE
SES-LFE
UAS-LFE
FC-LFE

CV-PFE
ES-PFE
SES-PFE
UAS-PFE
FC-PFE



Note If the CV-L(NE and FE) falls in the range 51-61 for EC1,then, the user might see discrepancy in the SES and the UAS-L values. However, ES-L will be in the nearest accuracy. For a few seconds, in a given 10 seconds interval, the number of CV-L counted may not cross the CV count criteria for SES, (due to system/application limitation for the below mentioned ranges) ;as a consequence of which there may not be 10 continuous SES, thus UAS will not be observed.


15.5.2  DS1_E1_56 Card Performance Monitoring Parameters

Figure 15-4 shows signal types that support near-end and far-end PMs.

Figure 15-4 Monitored Signal Types for the DS1/E1-56 Card

Figure 15-5 shows where overhead bytes detected on the ASICs produce PM parameters for the DS1/E1-56 card.

Figure 15-5 PM Read Points on the DS1/E1-56 Card

Table 15-5 lists the PM parameters for the DS1/E1-56 card.

Table 15-5 DS1/E1-56 Card PMs 

Line (NE)
Line (FE)
Rx Path (NE)
Tx Path (NE)
STS Path (NE)
Rx Path (FE)
STS Path (FE)
Network Path
BFDL (FE)

CV-L
ES-L
SES-L
LOSS-L

CV-L
ES-L

AISS-P
CV-P
ES-P
SES-P
SAS-P
UAS-P
CSS-P
ESA-P
ESB-P
SEFS-P

AISS-P
CV-P
ES-P
SES-P
UAS-P
BBER-P
SESR-P
ESR-P

CV-P
ES-P
SES-P
UAS-P
FC-P

ES-PFE
ESA-PFE
ESB-PFE
CV-PFE
CSS-PFE
SEFS-PFE
SES-PFE
UAS-PFE

CV-PFE
ES-PFE
SES-PFE
UAS-PFE
FC-PFE

ES-NP
ES-NPFE
SES-NP
SES-NPFEUAS-NP
UAS-NPFE

CSS
ES
SES
BES
UAS
LOFC


15.5.3  DS1-14 and DS1N-14 Card Performance Monitoring Parameters

Figure 15-6 shows the signal types that support near-end and far-end PMs.

Figure 15-6 Monitored Signal Types for the DS1-14 and DS1N-14 Cards


Note The XX in Figure 15-6 represents all PMs listed in Table 15-6 with the given prefix and/or suffix.


Figure 15-7 shows where overhead bytes detected on the ASICs produce PM parameters for the DS1-14 and DS1N-14 cards.

Figure 15-7 PM Read Points on the DS1-14 and DS1N-14 Cards

Table 15-6 describes the PM parameters for the DS1-14 and DS1N-14 cards.

Table 15-6 DS1-14 and DS1N-14 Card PMs 

Line (NE)
Line (FE)
Rx Path (NE)
Tx Path (NE)
VT Path (NE)
STS Path (NE)
Rx Path (FE)
VT Path (FE)
STS Path (FE)

CV-L
ES-L
SES-L
LOSS-L

CV-L
ES-L

AISS-P
CV-P
ES-P
FC-P
SAS-P
SES-P
UAS-P
CSS-P
ESA-P
ESB-P
SEFS-P

AISS-P
CV-P
ES-P
FC-P
SAS-P
SES-P
UAS-P

CV-V
ES-V
SES-V
UAS-V
FC-V

CV-P
ES-P
SES-P
UAS-P
FC-P

ES-PFE
ESA-PFE
ES-B-PFE
CV-PFE
CSS-PFE
SEFS-PFE
SES-PFE
UAS-PFE

CV-VFE
ES-VFE
SES-VFE
UAS-VFE
FC-VFE

CV-PFE
ES-PFE
SES-PFE
UAS-PFE
FC-PFE



Note Far-end DS1 performance monitoring values are valid only when the DS1 line is set to extended super frame (ESF).


15.5.3.1  DS-1 Facility Data Link Performance Monitoring

Facility Data Link (FDL) performance monitoring enables an ONS 15454 DS1N-14 card to calculate and report DS-1 error rate performance measured at both the near-end and far-end of the FDL. The far-end information is reported as received on the FDL in a performance report message (PRM) from an intelligent channel service unit (CSU).

To monitor DS-1 FDL PM values, the DS-1 must be set to use ESF format and the FDL must be connected to an intelligent CSU. For procedures for provisioning ESF on the DS1N-14 card, refer to the Cisco ONS 15454 Procedure Guide.

The monitored DS-1 FDL PM parameters are CV-PFE, ES-PFE, ESA-PFE, ESB-PFE, SES-PFE, SEFS-PFE, CSS-PFE, UAS-PFE, FC-PFE, and ES-LFE. See Table 15-3 for detailed information and definitions of specific FDL DS1 PM parameters.

15.5.4  DS3-12 and DS3N-12 Card Performance Monitoring Parameters

Figure 15-8 shows the signal types that support near-end and far-end PMs. Figure 15-9 shows where overhead bytes detected on the ASICs produce PM parameters for the DS3-12 and DS3N-12 cards.

Figure 15-8 Monitored Signal Types for the DS3-12 and DS3N-12 Cards


Note The XX in Figure 15-8 represents all PMs listed in Table 15-7 with the given prefix and/or suffix.


Figure 15-9 PM Read Points on the DS3-12 and DS3N-12 Cards

The PM parameters for the DS3-12 and DS3N-12 cards are described in Table 15-7.

Table 15-7 DS3-12 and DS3N-12 Card PMs 

Line (NE)
STS Path (NE)
STS Path (FE)

CV-L
ES-L
SES-L
LOSS-L

CV-P
ES-P
SES-P
UAS-P
FC-P

CV-PFE
ES-PFE
SES-PFE
UAS-PFE
FC-PFE


15.5.5  DS3-12E and DS3N-12E Card Performance Monitoring Parameters

Figure 15-10 shows the signal types that support near-end and far-end PMs.

Figure 15-10 Monitored Signal Types for the DS3-12E and DS3N-12E Cards


Note The XX in Figure 15-10 represents all PMs listed in Table 15-8 with the given prefix and/or suffix.


Figure 15-11 shows where overhead bytes detected on the ASICs produce PM parameters for the DS3-12E and DS3N-12E cards.

Figure 15-11 PM Read Points on the DS3-12E and DS3N-12E Cards

Table 15-8 describes the PM parameters for the DS3-12E and DS3N-12E cards.

Table 15-8 DS3-12E and DS3N-12E Card PMs 

Line (NE)
Path (NE)
STS Path (NE)
Path (FE)1
STS Path (FE)

CV-L
ES-L
SES-L
LOSS-L

AISS-P
CV-P
ES-P
SAS-P2
SES-P
UAS-P
CVCP-P
ESCP-P
SASCP-P3
SESCP-P
UASCP-P

CV-P
ES-P
SES-P
UAS-P
FC-P

CVCP-PFE
ESCP-PFE
SASCP-P
SESCP-PFE
UASCP-PFE

CV-PFE
ES-PFE
SES-PFE
UAS-PFE
FC-PFE

1 The C-bit PMs (PMs that contain the text "CP-P") are applicable only if the line format is C-bit.

2 DS3(N)-12E cards support SAS-P only on the receive (Rx) path.

3 The SASCP parameter is also displayed as "undefined" for near-end parameter though it is a far-end parameter.


15.5.6  DS3i-N-12 Card Performance Monitoring Parameters

Figure 15-12 shows the signal types that support near-end and far-end PMs.

Figure 15-12 Monitored Signal Types for the DS3i-N-12 Cards


Note The XX in Figure 15-12 represents all PMs listed in Table 15-9 with the given prefix and/or suffix.


Figure 15-13 shows where overhead bytes detected on the ASICs produce PM parameters for the DS3i-N-12 cards.

Figure 15-13 PM Read Points on the DS3i-N-12 Cards

Table 15-9 describes the PM parameters for the DS3i-N-12 card.

Table 15-9 DS3i-N-12 Card PMs 

Line (NE)
Path (NE)
STS Path (NE)
Path (FE)1
STS Path (FE)

CV-L
ES-L
SES-L
LOSS-L

AISSP-P
CVP-P
ESP-P
SASP-P2
SESP-P
UASP-P
CVCP-P
ESCP-P
SASCP-P3
SESCP-P
UASCP-P

CV-P
ES-P
SES-P
UAS-P
FC-P

CVCP-PFE
ESCP-PFE
SASCP-PFE
SESCP-PFE
UASCP-PFE

CV-PFE
ES-PFE
SES-PFE
UAS-PFE
FC-PFE

1 The C-Bit PMs (PMs that contain the text "CP-P") are applicable only if the line format is C-Bit.

2 DS3i-N-12 cards support SAS-P only on the Rx path.

3 The SASCP parameter is also displayed as "undefined" for near-end parameter though it is a far-end parameter.


15.5.7  DS3XM-6 Card Performance Monitoring Parameters

Figure 15-14 shows the signal types that support near-end and far-end PMs.

Figure 15-14 Monitored Signal Types for the DS3XM-6 Card


Note The XX in Figure 15-14 represents all PMs listed in Table 15-10 with the given prefix and/or suffix.


Figure 15-15 shows where the overhead bytes detected on the ASICs produce PM parameters for the DS3XM-6 card.

Figure 15-15 PM Read Points on the DS3XM-6 Card

Table 15-10 lists the PM parameters for the DS3XM-6 cards.

Table 15-10 DS3XM-6 Card PMs 

DS3 Line (NE)
DS3 Path (NE)1
DS1 Path (NE)
VT Path (NE)
STS Path (NE)
DS3 Path (FE) 1
VT Path (FE)
STS Path (FE)

CV-L
ES-L
SES-L
LOSS-L

AISS-P
CVP-P
ESP-P
SASP-P2
SESP-P
UASP-P
ESCP-P
SASCP-P3
SESCP-P
UASCP-P
CVCP-P

AISS-P
ES-P
SAS-P 2
SES-P
UAS-P

CV-V
ES-V
SES-V
UAS-V

CV-P
ES-P
SES-P
UAS-P
FC-P

CVCP-PFE
ESCP-PFE
SASCP-PFE
SESCP-PFE
UASCP-PFE

CV-VFE
ES-VFE
SES-VFE
UAS-VFE

CV-PFE
ES-PFE
SES-PFE
UAS-PFE
FC-PFE

1 The C-Bit PMs (PMs that contain the text "CP-P") are applicable only if the line format is C-Bit.

2 DS3XM-6 cards support SAS-P only on the Rx path.

3 The SASCP parameter is also displayed as "undefined" for near-end parameter though it is a far-end parameter.


15.5.8  DS3XM-12 Card Performance Monitoring Parameters

Figure 15-16 shows the signal types that support near-end and far-end PMs.

Figure 15-16 Monitored Signal Types for the DS3XM-12 Card


Note The XX in Figure 15-16 represents all PMs listed in Table 15-11 with the given prefix and/or suffix.


Figure 15-17 shows where the overhead bytes detected on the ASICs produce PM parameters for the DS3XM-12 card.

Figure 15-17 PM Read Points on the DS3XM-12 Card

Table 15-11 lists the PM parameters for the DS3XM-12 cards.

Table 15-11 DS3XM-12 Card PMs 

DS3 Line (NE)
DS3 Path (NE)1
DS1 Path (NE)
VT Path (NE)
STS Path (NE)
DS3 Path (FE) 1
VT Path (FE)
STS Path (FE)
BFDL (FE)

CV-L
ES-L
SES-L
LOSS-L

AISS-P
CV-P
ES-P
SAS-P2
SES-P
UAS-P
ESCP-P
SESCP-P
UASCP-P
CVCP-P

AISS-P
CV-P
ES-P
FC-P
SAS-P 2
SES-P
UAS-P
CSS-P
ESA-P
ESB-P
SEFS-P

CV-V
ES-V
SES-V
UAS-V

CV-P
ES-P
SES-P
UAS-P
FC-P

CVCP-PFE
ESCP-PFE
SASCP-PFE3
SESCP-PFE
UASCP-PFE

CV-VFE
ES-VFE
SES-VFE
UAS-VFE

CV-PFE
ES-PFE
SES-PFE
UAS-PFE
FC-PFE

CSS
ES
SES
BES
UAS
LOFC

1 The C-Bit PMs (PMs that contain the text "CP-P") are applicable only if the line format is C-Bit.

2 DS3XM-12 cards support SAS-P only on the Rx path.

3 The SASCP parameter is also displayed as "undefined" for near-end parameter though it is a far-end parameter.


15.5.9  DS3-EC1-48 Card Performance Monitoring Parameters

Figure 15-18 shows the signal types that support near-end and far-end PMs.

Figure 15-18 Monitored Signal Types for the DS3/ EC1-48 Card


Note The XX in Figure 15-18 represents all PMs listed in Table 15-12 with the given prefix and/or suffix.


Figure 15-19 shows where the overhead bytes detected on the ASICs produce PM parameters for the DS3-EC1-48 card.

Figure 15-19 PM Read Points on the DS3/EC1-48 Card

Table 15-12 lists the PM parameters for the DS3/EC1-48 cards.

Table 15-12 DS3/EC1-48 Card PMs 

DS3/ EC1 Line (NE)
DS3 Path (NE)1
STS Path (NE)
DS3 Path (FE) 1
STS Path (FE)

CV-L
ES-L
SES-L
LOSS-L

AISS-P
CVP-P
ESP-P
SASP-P2
SESP-P
UASP-P
ESCP-P
SASCP-P3
SESCP-P
UASCP-P
CVCP-P

CV-P
ES-P
SES-P
UAS-P
FC-P

CVCP-PFE
ESCP-PFE
SASCP-PFE
SESCP-PFE
UASCP-PFE

CV-PFE
ES-PFE
SES-PFE
UAS-PFE
FC-PFE

1 The C-Bit PMs (PMs that contain the text "CP-P") are applicable only if the line format is C-Bit.

2 DS3/EC1-48 cards support SAS-P only on the Rx path.

3 The SASCP parameter is also displayed as "undefined" for near-end parameter though it is a far-end parameter.



Note If the CV-L(NE and FE) falls in the range 51-61 for DS3,then, the user might see discrepancy in the SES and the UAS-L values. However, ES-L will be in the nearest accuracy. For a few seconds, in a given 10 seconds interval, the number of CV-L counted may not cross the CV count criteria for SES, (due to system/application limitation for the below mentioned ranges); as a consequence of which there may not be 10 continuous SES, thus UAS will not be observed.


15.6  Performance Monitoring for Ethernet Cards

The following sections define PM parameters and definitions for the ONS 15454 E-Series, G-Series, ML-Series, and CE-Series Ethernet cards.

15.6.1  E-Series Ethernet Card Performance Monitoring Parameters

CTC provides Ethernet performance information, including line-level parameters, port bandwidth consumption, and historical Ethernet statistics. The E-Series Ethernet performance information is divided into the Statistics, Utilization, and History tabbed windows within the card view Performance tab window.

15.6.1.1  E-Series Ethernet Statistics Window

The Ethernet Statistics window lists Ethernet parameters at the line level. The Statistics window provides buttons to change the statistical values shown. The Baseline button resets the displayed statistics values to zero. The Refresh button manually refreshes statistics. Auto-Refresh sets a time interval at which automatic refresh occurs.

Table 15-13 defines the E-Series Ethernet card statistics parameters.

Table 15-13 E-Series Ethernet Statistics Parameters 

Parameter
Definition

Link Status

Indicates whether link integrity is present; up means present, and down means not present.

ifInOctets

Number of bytes received since the last counter reset.

ifInUcastPkts

Number of unicast packets received since the last counter reset.

ifInErrors

The number of inbound packets (or transmission units) that contained errors preventing them from being deliverable to a higher-layer protocol.

ifOutOctets

Number of bytes transmitted since the last counter reset.

ifOutUcastPkts

Number of unicast packets transmitted.

dot3StatsAlignmentErrors

A count of frames received on a particular interface that are not an integral number of octets in length and do not pass the FCS check.

dot3StatsFCSErrors

A count of frames received on a particular interface that are an integral number of octets in length but do not pass the FCS check.

dot3StatsFrameTooLong

A count of frames received on a particular interface that exceed the maximum permitted frame size.

etherStatsUndersizePkts

The total number of packets received that were less than 64 octets long (excluding framing bits, but including FCS octets) and were otherwise well formed.

etherStatsFragments

The total number of packets received that were less than 64 octets in length (excluding framing bits but including FCS octets) and had either a bad FCS with an integral number of octets (FCS Error) or a bad FCS with a nonintegral number of octets (Alignment Error).

Note It is entirely normal for etherStatsFragments to increment. This is because it counts both runts (which are normal occurrences due to collisions) and noise hits.

etherStatsPkts64Octets

The total number of packets (including bad packets) received that were 64 octets in length (excluding framing bits but including FCS octets).

etherStatsPkts65to127
Octets

The total number of packets (including bad packets) received that were between 65 and 127 octets in length inclusive (excluding framing bits but including FCS octets).

etherStatsPkts128to255
Octets

The total number of packets (including bad packets) received that were between 128 and 255 octets in length inclusive (excluding framing bits but including FCS octets).

etherStatsPkts256to511
Octets

The total number of packets (including bad packets) received that were between 256 and 511 octets in length inclusive (excluding framing bits but including FCS octets).

etherStatsPkts512to1023Octets

The total number of packets (including bad packets) received that were between 512 and 1023 octets in length inclusive (excluding framing bits but including FCS octets).

etherStatsPkts1024to1518Octets

The total number of packets (including bad packets) received that were between 1024 and 1518 octets in length inclusive (excluding framing bits but including FCS octets).

etherStatsOversizePkts

The total number of packets received that were longer than 1518 octets (excluding framing bits, but including FCS octets) and were otherwise well formed. Note that for tagged interfaces, this number becomes 1522 bytes.

etherStatsJabbers

The total number of packets received that were longer than 1518 octets (excluding framing bits, but including FCS octets), and had either a bad FCS with an integral number of octets (FCS Error) or a bad FCS with a nonintegral number of octets (Alignment Error).

etherStatsOctets

The total number of octets of data (including those in bad packets) received on the network (excluding framing bits but including FCS octets

etherStatsCRCAlign
Errors

The total number of packets received that had a length (excluding framing bits, but including FCS octets) of between 64 and 1518 octets, inclusive, but had either a bad FCS with an integral number of octets (FCS Error) or a bad FCS with a nonintegral number of octets (Alignment Error).


15.6.1.2  E-Series Ethernet Utilization Window

The Utilization window shows the percentage of transmit (Tx) and receive (Rx) line bandwidth used by the Ethernet ports during consecutive time segments. The Mode field displays the real-time mode status, such as 100 Full, which is the mode setting configured on the E-Series port. However, if the E-Series port is set to autonegotiate the mode (Auto), this field shows the result of the link negotiation between the E-Series and the peer Ethernet device attached directly to the E-Series port.

The Utilization window provides an Interval drop-down list that enables you to set time intervals of 1 minute, 15 minutes, 1 hour, and 1 day. Line utilization is calculated with the following formulas:

Rx = (inOctets + inPkts * 20) * 8 / 100% interval * maxBaseRate

Tx = (outOctets + outPkts * 20) * 8 / 100% interval * maxBaseRate

The interval is defined in seconds. The maxBaseRate is defined by raw bits per second in one direction for the Ethernet port (that is, 1 Gbps). The maxBaseRate for E-Series Ethernet cards is shown in Table 15-14.

Table 15-14 maxBaseRate for STS Circuits 

STS
maxBaseRate

STS-1

51840000

STS-3c

155000000

STS-6c

311000000

STS-12c

622000000



Note Line utilization numbers express the average of ingress and egress traffic as a percentage of capacity.



Note The E-Series Ethernet card is a Layer 2 device or switch and supports Trunk Utilization statistics. The Trunk Utilization statistics are similar to the Line Utilization statistics, but shows the percentage of circuit bandwidth used rather than the percentage of line bandwidth used. The Trunk Utilization statistics are accessed through the card view Maintenance tab.


15.6.1.3  E-Series Ethernet History Window

The Ethernet History window lists past Ethernet statistics for the previous time intervals. Depending on the selected time interval, the History window displays the statistics for each port for the number of previous time intervals as shown in Table 15-15. The parameters are defined in Table 15-13.

Table 15-15 Ethernet History Statistics per Time Interval

Time Interval
Number of Previous Intervals Displayed

1 minute

60

15 minutes

32

1 hour

24

1 day (24 hours)

7


15.6.2  G-Series Ethernet Card Performance Monitoring Parameters

CTC provides Ethernet performance information, including line-level parameters, port bandwidth consumption, and historical Ethernet statistics. The G-Series Ethernet performance information is divided into the Statistics, Utilization, and History tabbed windows within the card view Performance tab window.

15.6.2.1  G-Series Ethernet Statistics Window

The Ethernet Statistics window lists Ethernet parameters at the line level. The Statistics window provides buttons to change the statistical values shown. The Baseline button resets the displayed statistics values to zero. The Refresh button manually refreshes statistics. Auto-Refresh sets a time interval at which automatic refresh occurs. The G-Series Statistics window also has a Clear button. The Clear button sets the values on the card to zero, but does not reset the G-Series card.

Table 15-16 defines the G-Series Ethernet card statistics parameters.

Table 15-16 G-Series Ethernet Statistics Parameters 

Parameter
Definition

Time Last Cleared

A time stamp indicating the last time statistics were reset.

Link Status

Indicates whether the Ethernet link is receiving a valid Ethernet signal (carrier) from the attached Ethernet device; up means present, and down means not present.

Rx Packets

Number of packets received since the last counter reset.

Rx Bytes

Number of bytes received since the last counter reset.

Tx Packets

Number of packets transmitted since the last counter reset.

Tx Bytes

Number of bytes transmitted since the last counter reset.

Rx Total Errors

Total number of receive errors.

Rx FCS

Number of packets with a FCS error. FCS errors indicate frame corruption during transmission.

Rx Alignment

Number of packets with received incomplete frames.

Rx Runts

Measures undersized packets with bad CRC errors.

Rx Shorts

Measures undersized packets with good CRC errors.

Rx Jabbers

The total number of frames received that exceed the 1548-byte maximum and contain CRC errors.

Rx Giants

Number of packets received that are greater than 1530 bytes in length.

Rx Pause Frames

Number of received Ethernet IEEE 802.3z pause frames.

Tx Pause Frames

Number of transmitted IEEE 802.3z pause frames.

Rx Pkts Dropped Internal Congestion

Number of received packets dropped due to overflow in G-Series frame buffer.

Tx Pkts Dropped Internal Congestion

Number of transmit queue drops due to drops in the G-Series frame buffer.

HDLC Errors

High-level data link control (HDLC) errors received from SONET/SDH (see Note).

Rx Unicast Packets

Number of unicast packets received since the last counter reset.

Tx Unicast Packets

Number of unicast packets transmitted.

Rx Multicast Packets

Number of multicast packets received since the last counter reset.

Tx Multicast Packets

Number of multicast packets transmitted.

Rx Broadcast Packets

Number of broadcast packets received since the last counter reset.

Tx Broadcast Packets

Number or broadcast packets transmitted.



Note Do not use the HDLC errors counter to count the number of frames dropped because of HDLC errors, because each frame can fragment into several smaller frames during HDLC error conditions and spurious HDLC frames can be generated. If HDLC error counters are incrementing when no SONET path problems should be present, it might indicate a problem with the quality of the SONET path. For example, a SONET protection switch generates a set of HDLC errors. However, the actual values of these counters are less significant than the fact that they are changing.


15.6.2.2  G-Series Ethernet Utilization Window

The Utilization window shows the percentage of Tx and Rx line bandwidth used by the Ethernet ports during consecutive time segments. The Mode field displays the real-time mode status, such as 100 Full, which is the mode setting configured on the G-Series port. However, if the G-Series port is set to autonegotiate the mode (Auto), this field shows the result of the link negotiation between the G-Series and the peer Ethernet device attached directly to the G-Series port.

The Utilization window provides an Interval drop-down list that enables you to set time intervals of 1 minute, 15 minutes, 1 hour, and 1 day. Line utilization is calculated with the following formulas:

Rx = (inOctets + inPkts * 20) * 8 / 100% interval * maxBaseRate

Tx = (outOctets + outPkts * 20) * 8 / 100% interval * maxBaseRate

The interval is defined in seconds. The maxBaseRate is defined by raw bits per second in one direction for the Ethernet port (that is, 1 Gbps). The maxBaseRate for G-Series Ethernet cards is shown in Table 15-14.


Note Line utilization numbers express the average of ingress and egress traffic as a percentage of capacity.



Note Unlike the E-Series, the G-Series card does not have a display of Trunk Utilization statistics, because the G-Series card is not a Layer 2 device or switch.


15.6.2.3  G-Series Ethernet History Window

The Ethernet History window lists past Ethernet statistics for the previous time intervals. Depending on the selected time interval, the History window displays the statistics for each port for the number of previous time intervals as shown in Table 15-15. The listed parameters are defined in Table 15-16.

15.6.3  ML-Series Ethernet Card Performance Monitoring Parameters

CTC provides Ethernet performance information for line-level parameters and historical Ethernet statistics. The ML-Series Ethernet performance information is divided into the Ether Ports and Packet-over-SONET (POS) Ports tabbed windows within the card view Performance tab window.

15.6.3.1  ML-Series Ether Ports Window

Table 15-17 defines the ML-Series Ethernet card Ether Ports PM parameters.

Table 15-17 ML-Series Ether Ports PM Parameters 

Parameter
Definition

ifInOctets

Number of bytes received since the last counter reset.

rxTotalPackets

Number of packets received.

ifInUcastPkts

Number of unicast packets received since the last counter reset.

ifInMulticast Pkts

Number of multicast packets received since the last counter reset.

ifInBroadcast Pkts

Number of broadcast packets received since the last counter reset.

ifInDiscards

The number of inbound packets that were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space.

ifOutOctets

Number of bytes transmitted since the last counter reset.

txTotalPkts

Number of transmitted packets.

ifOutUcast Pkts

Number of unicast packets transmitted.

ifOutMulticast Pkts

Number of multicast packets transmitted.

ifOutBroadcast Pkts

Number or broadcast packets transmitted.

dot3StatsAlignmentErrors

A count of frames received on a particular interface that are not an integral number of octets in length and do not pass the FCS check.

dot3StatsFCSErrors

A count of frames received on a particular interface that are an integral number of octets in length but do not pass the FCS check.

etherStatsUndersizePkts

The total number of packets received that were less than 64 octets long (excluding framing bits, but including FCS octets) and were otherwise well formed.

etherStatsOversizePkts

The total number of packets received that were longer than 1518 octets (excluding framing bits, but including FCS octets) and were otherwise well formed. Note that for tagged interfaces, this number becomes 1522 bytes.

etherStatsJabbers

The total number of packets received that were longer than 1518 octets (excluding framing bits, but including FCS octets), and had either a bad FCS with an integral number of octets (FCS Error) or a bad FCS with a nonintegral number of octets (Alignment Error).

etherStatsCollissions

Number of transmit packets that are collisions; the port and the attached device transmitting at the same time caused collisions.

etherStatsDropEvents

Number of received frames dropped at the port level.

rx PauseFrames

Number of received Ethernet 802.3z pause frames.

mediaIndStatsOversize
Dropped

Number of received oversized packages that are dropped.

mediaIndStatsTxFrames
TooLong

Number of received frames that are too long. The maximum is the programmed max frame size (for virtual SAN [VSAN] support); if the maximum frame size is set to default, then the maximum is a 2112 byte payload plus the 36 byte header, which is a total of 2148 bytes.


15.6.3.2  ML-Series POS Ports Window

In the ML-Series POS Ports window, the parameters displayed depend on the framing mode employed by the ML-Series card. The two framing modes for the POS port on the ML-Series card are HDLC and frame-mapped generic framing procedure (GFP-F). For more information on provisioning a framing mode, refer to Cisco ONS 15454 Procedure Guide.

Table 15-18 defines the ML-Series Ethernet card POS Ports HDLC parameters. Table 15-19 defines the ML-Series Ethernet card POS Ports GFP-F parameters.

Table 15-18 ML-Series POS Ports Parameters for HDLC Mode 

Parameter
Definition

ifInOctets

Number of bytes received since the last counter reset.

rxTotalPkts

Number of packets received.

ifOutOctets

Number of bytes transmitted since the last counter reset.

tx TotalPkts

Number of transmitted packets.

etherStatsDropEvents

Number of received frames dropped at the port level.

rxPktsDropped Internal
Congestion

Number of received packets dropped due to overflow in frame buffer.

mediaIndStatsRxFramesTruncated

Number of received frames with a length of 36 bytes or less.

mediaIndStatsRxFramesTooLong

Number of received frames that are too long. The maximum is the programmed maximum frame size (for VSAN support); if the maximum frame size is set to default, then the maximum is the 2112 byte payload plus the 36 byte header, which is a total of 2148 bytes.

mediaIndStatsRxFramesBadCRC

Number of received frames with CRC errors.

mediaIndStatsRxShort
Pkts

Number of received packets that are too small.

hdlcInOctets

Number of bytes received (from the SONET/SDH path) prior to the bytes undergoing HLDC decapsulation by the policy engine.

hdlcRxAborts

Number of received packets aborted on input.

hdlcOutOctets

Number of bytes transmitted (to the SONET/SDH path) after the bytes undergoing HLDC encapsulation by the policy engine.


Table 15-19 ML-Series POS Ports Parameters for GFP-F Mode 

Parameter
Meaning

etherStatsDropEvents

Number of received frames dropped at the port level.

rx PktsDroppedInternal
Congestion

Number of received packets dropped due to overflow in the frame buffer.

gfpStatsRxFrame

Number of received GFP frames.

gfpStatsTxFrame

Number of transmitted GFP frames.

gfpStatsRxOctets

Number of GFP bytes received.

gfpStatsTxOctets

Number of GFP bytes transmitted.

gfpStatsRxSBitErrors

Sum of all the single bit errors. In the GFP CORE HDR at the GFP-T receiver, these are correctable.

gfpStatsRxMBitErrors

Sum of all the multiple bit errors. In the GFP CORE HDR at the GFP-T receiver, these are uncorrectable.

gfpStatsRxTypeInvalid

Number of receive packets dropped due to Client Data Frame UPI errors.

gfpStatsRxCRCErrors

Number of packets received with a payload FCS error.

gfpStatsLFDRaised

Count of core HEC CRC multiple bit errors.

Note This count is only of eHec multiple bit errors when in frame. This can be looked at as a count of when the state machine goes out of frame.

gfpStatsCSFRaised

Number of GFP Client signal fail frames detected at the GFP-T receiver.

mediaIndStatsRxFrames
Truncated

Number of received frames that are too long. The maximum is the programmed maximum frame size (for VSAN support); if the maximum frame size is set to default, then the maximum is the 2112 byte payload plus the 36 byte header, which is a total of 2148 bytes.

mediaIndStatsRxFramesToo
Long

Number of received frames with CRC error.s

mediaIndStatsRxShortPkts

Number of received packets that are too small.


15.6.4  CE-Series Ethernet Card Performance Monitoring Parameters

CTC provides Ethernet performance information, including line-level parameters, port bandwidth consumption, and historical Ethernet statistics. The CE-Series card Ethernet performance information is divided into Ether Ports and POS Ports tabbed windows within the card view Performance tab window.

15.6.4.1  CE-Series Card Ether Port Statistics Window

The Ethernet Ether Ports Statistics window lists Ethernet parameters at the line level. The Statistics window provides buttons to change the statistical values shown. The Baseline button resets the displayed statistics values to zero. The Refresh button manually refreshes statistics. Auto-Refresh sets a time interval at which automatic refresh occurs. The CE-Series Statistics window also has a Clear button. The Clear button sets the values on the card to zero, but does not reset the CE-Series card.

During each automatic cycle, whether auto-refreshed or manually refreshed (using the Refresh button), statistics are added cumulatively and are not immediately adjusted to equal total received packets until testing ends. To see the final PM count totals, allow a few moments for the PM window statistics to finish testing and update fully. PM counts are also listed in the CE-Series card Performance > History window.

Table 15-20 defines the CE-Series card Ethernet port parameters.

Table 15-20 CE-Series Ether Port PM Parameters 

Parameter
Definition

Time Last Cleared

A time stamp indicating the last time statistics were reset.

Link Status

Indicates whether the Ethernet link is receiving a valid Ethernet signal (carrier) from the attached Ethernet device; up means present, and down means not present.

ifInOctets

Number of bytes received since the last counter reset.

rxTotalPkts

Number of received packets.

ifInUcastPkts

Number of unicast packets received since the last counter reset.

ifInMulticastPkts

Number of multicast packets received since the last counter reset.

ifInBroadcastPkts

Number of broadcast packets received since the last counter reset.

ifInDiscards

The number of inbound packets that were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free buffer space.

ifInErrors

The number of inbound packets (or transmission units) that contained errors preventing them from being deliverable to a higher-layer protocol.

ifOutOctets

Number of bytes transmitted since the last counter reset.

txTotalPkts

Number of transmitted packets.

ifOutDiscards1

Number of outbound packets which were chosen to be discarded even though no errors had been detected to prevent their transmission. A possible reason for discarding such packets could be to free up buffer space.

ifOutErrors 1

Number of outbound packets or transmission units that could not be transmitted because of errors.

ifOutUcastPkts2

Number of unicast packets transmitted.

ifOutMulticastPkts 2

Number of multicast packets transmitted.

ifOutBroadcastPkts 2

Number of broadcast packets transmitted.

dot3StatsAlignment
Errors 2

A count of frames received on a particular interface that are not an integral number of octets in length and do not pass the FCS check.

dot3StatsFCSErrors

A count of frames received on a particular interface that are an integral number of octets in length but do not pass the FCS check.

dot3StatsSingleCollisionFrames 2

A count of successfully transmitted frames on a particular interface for which transmission is inhibited by exactly on collision.

dot3StatsFrameTooLong

A count of frames received on a particular interface that exceed the maximum permitted frame size.

etherStatsUndersizePkts

The total number of packets received that were less than 64 octets long (excluding framing bits, but including FCS octets) and were otherwise well formed.

etherStatsFragments

The total number of packets received that were less than 64 octets in length (excluding framing bits but including FCS octets) and had either a bad FCS with an integral number of octets (FCS Error) or a bad FCS with a nonintegral number of octets (Alignment Error).

Note It is entirely normal for etherStatsFragments to increment. This is because it counts both runts (which are normal occurrences due to collisions) and noise hits.

etherStatsPkts64Octets

The total number of packets (including bad packets) received that were 64 octets in length (excluding framing bits but including FCS octets).

etherStatsPkts65to127
Octets

The total number of packets (including bad packets) received that were between 65 and 127 octets in length inclusive (excluding framing bits but including FCS octets).

etherStatsPkts128to255
Octets

The total number of packets (including bad packets) received that were between 128 and 255 octets in length inclusive (excluding framing bits but including FCS octets).

etherStatsPkts256to511
Octets

The total number of packets (including bad packets) received that were between 256 and 511 octets in length inclusive (excluding framing bits but including FCS octets).

etherStatsPkts512to1023Octets

The total number of packets (including bad packets) received that were between 512 and 1023 octets in length inclusive (excluding framing bits but including FCS octets).

etherStatsPkts1024to1518Octets

The total number of packets (including bad packets) received that were between 1024 and 1518 octets in length inclusive (excluding framing bits but including FCS octets).

etherStatsBroadcastPkts

The total number of good packets received that were directed to the broadcast address. Note that this does not include multicast packets.

etherStatsMulticastPkts

The total number of good packets received that were directed to a multicast address. Note that this number does not include packets directed to the broadcast address.

etherStatsOversizePkts

The total number of packets received that were longer than 1518 octets (excluding framing bits, but including FCS octets) and were otherwise well formed. Note that for tagged interfaces, this number becomes 1522 bytes.

etherStatsJabbers

The total number of packets received that were longer than 1518 octets (excluding framing bits, but including FCS octets), and had either a bad FCS with an integral number of octets (FCS Error) or a bad FCS with a nonintegral number of octets (Alignment Error).

etherStatsOctets

The total number of octets of data (including those in bad packets) received on the network (excluding framing bits but including FCS octets

etherStatsCollisions 2

Number of transmit packets that are collisions; the port and the attached device transmitting at the same time caused collisions.

etherStatsCRCAlign
Errors 2

The total number of packets received that had a length (excluding framing bits, but including FCS octets) of between 64 and 1518 octets, inclusive, but had either a bad FCS with an integral number of octets (FCS Error) or a bad FCS with a nonintegral number of octets (Alignment Error).

etherStatsDropEvents 2

Number of received frames dropped at the port level.

rxPauseFrames 1

Number of received pause frames.

txPauseFrames 1

Number of transmitted pause frames.

rxPktsDroppedInternalCongestion 1

Number of received packets dropped due to overflow in frame buffer.

txPktsDroppedInternalCongestion 1

Number of transmit queue drops due to drops in frame buffer.

rxControlFrames 1

Number of received control frames.

mediaIndStatsRxFramesTruncated 1

Number of received frames with length of 36 bytes or less.

mediaIndStatsRxFramesTooLong 1

Number of received frames that are too long. The maximum is the programmed maximum frame size (for VSAN support); if the maximum frame size is set to default, then the maximum is the 2112 byte payload plus the 36 byte header, which is a total of 2148 bytes.

mediaIndStatsRxFramesBadCRC 1

Number of received frames with CRC error.

mediaIndStatsTxFramesBadCRC 1

Number of transmitted frames with CRC error.

mediaIndStatsRxShortPkts 1

Number of received packets that are too small.

1 For CE1000-4 only

2 For CE100T-8 only


15.6.4.2  CE-Series Card Ether Ports Utilization Window

The Ether Ports Utilization window shows the percentage of Tx and Rx line bandwidth used by the Ethernet ports during consecutive time segments. The Utilization window provides an Interval drop-down list that enables you to set time intervals of 1 minute, 15 minutes, 1 hour, and 1 day. Line utilization is calculated with the following formulas:

Rx = (inOctets + inPkts * 20) * 8 / 100% interval * maxBaseRate

Tx = (outOctets + outPkts * 20) * 8 / 100% interval * maxBaseRate

The interval is defined in seconds. The maxBaseRate is defined by raw bits per second in one direction for the Ethernet port (that is, 1 Gbps). The maxBaseRate for CE-Series Ethernet cards is shown in Table 15-14.


Note Line utilization numbers express the average of ingress and egress traffic as a percentage of capacity.


15.6.4.3  CE-Series Card Ether Ports History Window

The Ethernet Ether Ports History window lists past Ethernet statistics for the previous time intervals. Depending on the selected time interval, the History window displays the statistics for each port for the number of previous time intervals as shown in Table 15-15. The listed parameters are defined in Table 15-16.

15.6.4.4  CE-Series Card POS Ports Statistics Parameters

The Ethernet POS Ports statistics window lists Ethernet POS parameters at the line level. Table 15-21 defines the CE-Series Ethernet card POS Ports parameters.

Table 15-21 CE-Series Card POS Ports Parameters 

Parameter
Definition

Time Last Cleared

A time stamp indicating the last time that statistics were reset.

Link Status

Indicates whether the Ethernet link is receiving a valid Ethernet signal (carrier) from the attached Ethernet device; up means present, and down means not present.

ifInOctets

Number of bytes received since the last counter reset.

rxTotalPkts

Number of received packets.

ifInDiscards1

The number of inbound packets that were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free buffer space.

ifInErrors 1

The number of inbound packets (or transmission units) that contained errors preventing them from being deliverable to a higher-layer protocol.

ifOutOctets

Number of bytes transmitted since the last counter reset.

txTotalPkts

Number of transmitted packets.

ifOutOversizePkts 1

Packets greater than 1518 bytes transmitted out a port.

gfpStatsRxFrame2

Number of received GFP frames.

gfpStatsTxFrame 2

Number of transmitted GFP frames.

gfpStatsRxCRCErrors

Number of packets received with a payload FCS error.

gfpStatsRxOctets 2

Number of GFP bytes received.

gfpStatsTxOctets 2

Number of GFP bytes transmitted.

gfpStatsRxSBitErrors

Sum of all the single bit errors. In the GFP CORE HDR at the GFP-T receiver, these are correctable.

gfpStatsRxMBitErrors

Sum of all the multiple bit errors. In the GFP CORE HDR at the GFP-T receiver, these are uncorrectable.

gfpStatsRxTypeInvalid

Number of receive packets dropped due to Client Data Frame UPI errors.

gfpStatsRxCIDInvalid 1

Number of packets with invalid CID.

gfpStatsCSFRaised

Number of GFP Client signal fail frames detected at the GFP-T receiver.

ifInPayloadCrcErrors 1

Received payload CRC errors.

ifOutPayloadCrcErrors 1

Transmitted payload CRC errors.

hdlcPktDrops

Number of received packets dropped before input.

1 Applicable only for CE100T-8

2 Applicable only for CE1000-4


15.6.4.5  CE-Series Card POS Ports Utilization Window

The POS Ports Utilization window shows the percentage of Tx and Rx line bandwidth used by the POS ports during consecutive time segments. The Utilization window provides an Interval drop-down list that enables you to set time intervals of 1 minute, 15 minutes, 1 hour, and 1 day. Line utilization is calculated with the following formulas:

Rx = (inOctets * 8) / (interval * maxBaseRate)

Tx = (outOctets * 8) / (interval * maxBaseRate)

The interval is defined in seconds. The maxBaseRate is defined by raw bits per second in one direction for the Ethernet port (that is, 1 Gbps). The maxBaseRate for CE-Series cards is shown in Table 15-14.


Note Line utilization numbers express the average of ingress and egress traffic as a percentage of capacity.


15.6.4.6  CE-Series Card Ether Ports History Window

The Ethernet POS Ports History window lists past Ethernet POS ports statistics for the previous time intervals. Depending on the selected time interval, the History window displays the statistics for each port for the number of previous time intervals as shown in Table 15-15. The listed parameters are defined in Table 15-20.

15.7  Performance Monitoring for Optical Cards

This section lists PM parameters for ONS 15454 optical cards, including the OC-3, OC-12, OC-48, and OC-192 cards. Figure 15-20 shows the signal types that support near-end and far-end PMs.

Figure 15-20 Monitored Signal Types for the OC-3 Cards


Note The XX in Figure 15-20 represents all PMs listed in Table 15-22, Table 15-23, and Table 15-24 with the given prefix and/or suffix.


Figure 15-21 shows where overhead bytes detected on the ASICs produce PM parameters for the OC3 IR 4 SH 1310 and OC3 IR SH 1310-8 cards.

Figure 15-21 PM Read Points on the OC-3 Cards


Note For PM locations relating to protection switch counts, see the Telcordia GR-253-CORE document.


Table 15-22 and Table 15-23 list the PM parameters for OC-3 cards.

Table 15-22 OC-3 Card PMs 

Section (NE)
Line (NE)
STS Path (NE)
Line (FE)
STS Path (FE)1

CV-S
ES-S
SES-S
SEF-S

CV-L
ES-L
SES-L
UAS-L
FC-L
PSC (1+1)
PSD (1+1)

CV-P
ES-P
SES-P
UAS-P
FC-P
PPJC-PDET
NPJC-PDET
PPJC-PGEN
NPJC-PGEN
PPJC-PDET-P
PPJC-PGEN-P
PJC-DIFF

CV-LFE
ES-LFE
SES-LFE
UAS-LFE
FC-LFE

CV-PFE
ES-PFE
SES-PFE
UAS-PFE
FC-PFE

1 The STS Path (FE) PMs are valid only for the OC3-4 card on ONS 15454.


Table 15-23 OC3-8 Card PMs 

Section (NE)
Line (NE)
Physical Layer (NE)
STS Path (NE)
Line (FE)
STS Path (FE)

CV-S
ES-S
SES-S
SEF-S

CV-L
ES-L
SES-L
UAS-L
FC-L
PSC (1+1)
PSD (1+1)

LBCL
OPT
OPR

CV-P
ES-P
SES-P
UAS-P
FC-P
PPJC-PDET-P
NPJC-PDET-P
PPJC-PGEN-P
NPJC-PGEN-P
PJCS-PDET-P
PJCS-PGEN-P
PJC-DIFF-P

CV-LFE
ES-LFE
SES-LFE
UAS-LFE
FC-LFE

CV-PFE
ES-PFE
SES-PFE
UAS-PFE
FC-PFE


Table 15-24 lists the PM parameters for OC-12, OC-48, and OC-192 cards.

Table 15-24 OC-12, OC-48, OC-192 Card PMs

Section (NE)
Line (NE)
STS Path (NE)
Line (FE)

CV-S
ES-S
SES-S
SEF-S

CV-L
ES-L
SES--L
UASL
FC-L
PSC (1+1, 2F BLSR)
PSD (1+1, 2F BLSR)
PSC-W (4F BLSR)
PSD-W (4F BLSR)
PSC-S (4F BLSR)
PSD-S (4F BLSR)
PSC-R (4F BLSR)
PSD-R (4F BLSR)

CV-P
ES-P
SES-P
UAS-P
FC-P
PPJC-PDET-P
NPJC-PDET-P
PPJC-PGEN-P
NPJC-PGEN-P
PJCS-PGEN-P
PJCS-PDET-P
PJC-DIFF-P

CV-L
ES-L
SES-L
UAS-L
FC-L



Note If the CV-L(NE and FE) falls in a specific range, then, the user might see discrepancy in the SES and the UAS-L values. However, ES-L will be in the nearest accuracy. For a few seconds, in a given 10 seconds interval, the number of CV-L counted may not cross the CV count criteria for SES, (due to system/application limitation for the below mentioned ranges); as a consequence of which there may not be 10 continuous SES, thus UAS will not be observed. The corresponding (error) range for the line rates is as shown in Table 15-25.


Table 15-25 Table of Border Error Rates

Line Rate
Error Ranges

OC3

154-164

OC12

615-625

OC48

2459-2470

OC192

9835-9845


15.8  Performance Monitoring for Optical Multirate Cards

This section lists PM parameters for the optical mutirate card, also known as the MRC-12 card.

Figure 15-22 shows where overhead bytes detected on the ASICs produce PM parameters for the MRC-12 card.

Figure 15-22 PM Read Points for the MRC-12 Card

Table 15-26 lists the PM parameters for MRC-12 cards.

Table 15-26 MRC-12 Card PMs

Section (NE)
Line (NE)
Line (FE)

CV-S
ES-S
SEF-S

CV-L
ES-L
SES-L
UASL
FC-L

CV-L
ES-L
SES-L
UAS-L
FC-L


15.9  Performance Monitoring for Storage Access Networking Cards

The following sections define PM parameters and definitions for the SAN card, also known as the FC_MR-4 or Fibre Channel card.

CTC provides FC_MR-4 performance information, including line-level parameters, port bandwidth consumption, and historical statistics. The FC_MR-4 card performance information is divided into the Statistics, Utilization, and History tabbed windows within the card view Performance tab window.

15.9.1  FC_MR-4 Statistics Window

The Statistics window lists parameters at the line level. The Statistics window provides buttons to change the statistical values shown. The Baseline button resets the displayed statistics values to zero. The Refresh button manually refreshes statistics. Auto-Refresh sets a time interval at which automatic refresh occurs. The Statistics window also has a Clear button. The Clear button sets the values on the card to zero. All counters on the card are cleared. Table 15-27 defines the FC_MR-4 card statistics parameters.

Table 15-27 FC_MR-4 Statistics Parameters 

Parameter
Definition

Time Last Cleared

A time stamp indicating the last time statistics were reset.

Link Status

Indicates whether the Fibre Channel link is receiving a valid Fibre Channel signal (carrier) from the attached Fibre Channel device; up means present, and down means not present.

Rx Frames

A count of the number of Fibre Channel frames received without errors.

Rx Bytes

A count of the number of bytes received without error for the Fibre Channel payload.

Tx Frames

A count of the number of transmitted Fibre Channel frames.

Tx Bytes

A count of the number of bytes transmitted from the Fibre Channel frame.

8b/10b Errors

A count of 10b errors received by the serial/deserializer (serdes 8b/10b).

Encoding Disparity Errors

A count of the disparity errors received by serdes.

Link Recoveries

A count of the FC_MR-4 software-initiated link recovery attempts toward the FC line side because of SONET protection switches.

Rx Frames bad CRC

A count of the received Fibre Channel frames with errored CRCs.

Tx Frames bad CRC

A count of the transmitted Fibre Channel frames with errored CRCs.

Rx Undersized Frames

A count of the received Fibre Channel frames less than 36 bytes including CRC, start of frame (SOF), and end of frame (EOF).

Rx Oversized Frames

A count of the received Fibre Channel frames greater than 2116 bytes of the payload. Four bytes are allowed for supporting VSAN tags sent.

GFP Rx HDR Single-bit Errors

A count of generic framing procedure (GFP) single bit errors in the core header error check (CHEC).

GFP Rx HDR Multi-bit Errors

A count of GFP multibit errors in CHEC.

GGFP Rx Frames Invalid Type

A count of GFP invalid user payload identifier (UPI) field in the type field.

GFP Rx Superblk CRC Errors

A count of superblock CRC errors in the transparent GFP frame.


15.9.2  FC_MR-4 Utilization Window

The Utilization window shows the percentage of Tx and Rx line bandwidth used by the ports during consecutive time segments. The Utilization window provides an Interval drop-down list that enables you to set time intervals of 1 minute, 15 minutes, 1 hour, and 1 day. Line utilization is calculated with the following formulas:

Rx = (inOctets + inPkts * 24) * 8 / 100% interval * maxBaseRate

Tx = (outOctets + outPkts * 24) * 8 / 100% interval * maxBaseRate

The interval is defined in seconds. The maxBaseRate is defined by raw bits per second in one direction for the port (that is, 1 Gbps or 2 Gbps). The maxBaseRate for FC_MR-4 cards is shown in Table 15-28.

Table 15-28 maxBaseRate for STS Circuits 

STS
maxBaseRate

STS-24

850000000

STS-48

850000000 x 21

1 For 1 Gbps of bit rate being transported, there are only 850 Mbps of actual data because of 8b->10b conversion. Similarly, for 2 Gbps of bit rate being transported, there are only 1700 Mbps (850 Mbps x 2) of actual data.



Note Line utilization numbers express the average of ingress and egress traffic as a percentage of capacity.


15.9.3  FC_MR-4 History Window

The History window lists past FC_MR-4 statistics for the previous time intervals. Depending on the selected time interval, the History window displays the statistics for each port for the number of previous time intervals as shown in Table 15-29. The listed parameters are defined in Table 15-27.

Table 15-29 FC_MR-4 History Statistics per Time Interval 

Time Interval
Number of Intervals Displayed

1 minute

60 previous time intervals

15 minutes

32 previous time intervals

1 hour

24 previous time intervals

1 day (24 hours)

7 previous time intervals



hometocprevnextglossaryfeedbacksearchhelp

Posted: Tue Oct 9 05:45:46 PDT 2007
All contents are Copyright © 1992--2007 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.