|
Table Of Contents
NTP-G76 Verify Optical Span Loss Using CTC
NTP-G77 Manage Automatic Power Control
DLP-G157 Disable Automatic Power Control
DLP-G158 Enable Automatic Power Control
DLP-G159 Refresh Automatic Power Control Information
NTP-G78 View ROADM Node Power Equalization
NTP-G80 Change Node Management Information
DLP-G160 Change the Node Name, Date, Time, and Contact Information
DLP-G161 Change the Login Legal Disclaimer
NTP-G134 Modify OSI Provisioning
DLP-G284 Modify the TARP Operating Parameters
DLP-G286 Remove a Static TID to NSAP Entry from the TARP Data Cache
DLP-G287 Add a TARP Manual Adjacency Table Entry
DLP-G292 Remove a TARP Manual Adjacency Table Entry
DLP-G293 Change the OSI Routing Mode
DLP-G294 Edit the OSI Router Configuration
DLP-G295 Edit the OSI Subnetwork Point of Attachment
DLP-G296 Edit an IP-Over-CLNS Tunnel
DLP-G297 Delete an IP-Over-CLNS Tunnel
NTP-G81 Change CTC Network Access
DLP-G266 Modify Backplane Port IP Settings in Security Mode
DLP-G267 Disable Node Security Mode
DLP-G163 Modify a Static Route
DLP-G164 Delete a Static Route
DLP-G167 Delete a Firewall Tunnel
NTP-G82 Customize the CTC Network View
DLP-G168 Change the Network View Background Color
DLP-G169 Change the Default Network View Background Map
DLP-G170 Apply a Custom Network View Background Map
DLP-G173 Enable Dialog Box Do-Not-Display Option
DLP-G174 Switch Between TDM and DWDM Network Views
DLP-G330 Consolidate Links in Network View
NTP-G83 Modify or Delete Card Protection Settings
DLP-G175 Modify a Y-Cable Protection Group
DLP-G176 Modify a Splitter Protection Group
DLP-G177 Delete a Y-Cable Protection Group
NTP-G84 Initiate and Clear Y-Cable and Splitter External Switching Commands
DLP-G178 Apply a Manual Y-Cable or Splitter Protection Switch
DLP-G179 Apply a Force Y-Cable or Splitter Protection Switch
DLP-G180 Clear a Manual or Force Y-Cable or Splitter Protection Switch
DLP-G183 Clear a Lock-On or Lockout
NTP-G85 Modify or Delete OSC Terminations, GCC Terminations, and Provisionable Patchcords
DLP-G184 Change a GCC Termination
DLP-G185 Delete a GCC Termination
DLP-G186 Delete an OSC Termination
DLP-G187 Delete a Provisionable Patchcord
NTP-G86 Convert a Pass-Through Connection to Add/Drop Connections
NTP-G87 Change Node Timing Parameters
NTP-G88 Modify Users and Change Security
DLP-G188 Change Security Policy for a Single Node
DLP-G189 Change Security Policy for Multiple Nodes
DLP-G317 Change Node Access and PM Clearing Privilege
DLP-G328 Grant Superuser Privileges to a Provisioning User
DLP-G191 Change User Password and Security Level on a Single Node
DLP-G192 Change User Password and Security Level for Multiple Nodes
DLP-G193 Delete a User From a Single Node
DLP-G194 Delete a User From Multiple Nodes
DLP-G195 Log Out a User on a Single Node
DLP-G196 Log Out a User on Multiple Nodes
DLP-G281 Configure the Node for RADIUS Authentication
DLP-G282 View and Terminate Active Logins
NTP-G131 Convert DWDM Nodes to Hybrid Nodes
DLP-G197 Modify SNMP Trap Destinations
DLP-G198 Delete SNMP Trap Destinations
Manage the Node
This chapter explains how to modify node provisioning for the Cisco ONS 15454 and perform common management tasks such as monitoring the dense wavelength division multiplexing (DWDM) automatic power control (APC) and span loss values. To provision a new node, see Chapter 3, "Turn Up a Node." To change default network element (NE) settings and to view a list of those settings, refer to the "Network Element Defaults" appendix in the Cisco ONS 15454 DWDM Reference Manual.
Note Unless otherwise specified, "ONS 15454" refers to both ANSI and ETSI shelf assemblies.
Before You Begin
Before performing the following procedures, investigate all alarms and clear any trouble conditions. Refer to the Cisco ONS 15454 DWDM Troubleshooting Guide as necessary.
This section lists the chapter procedures (NTPs). Turn to a procedure for applicable tasks (DLPs).
1. G76 Verify Optical Span Loss Using CTC—Complete this procedure as needed to view or modify the DWDM span loss values.
2. G77 Manage Automatic Power Control—Complete this procedure as needed to manage the DWDM APC.
3. G78 View ROADM Node Power Equalization—Complete this procedure as needed to view and update a reconfigurable optical add/drop multiplexing (ROADM) node's power equalization.
4. G80 Change Node Management Information—Complete this procedure as needed to change node name, contact information, latitude, longitude, date, time, and login legal disclaimer.
5. G134 Modify OSI Provisioning—Complete this procedure as needed to modify Open System Interconnection (OSI) parameters including the OSI routing mode, Target Identifier Address Resolution Protocol (TARP), routers, subnets, and IP-over-connectionless network service (CLNS) tunnels.
6. G81 Change CTC Network Access—Complete this procedure as needed to change the IP address, default router, subnet mask, network configuration settings, and static routes.
7. G82 Customize the CTC Network View—Complete this procedure as needed to create domains and customize the appearance of the network map, including specifying a different default map, creating domains, consolidating links in the network view, selecting your own map or image, and changing the background color.
8. G83 Modify or Delete Card Protection Settings—Complete this procedure as needed.
9. G84 Initiate and Clear Y-Cable and Splitter External Switching Commands—Complete this procedure as needed.
10. G85 Modify or Delete OSC Terminations, GCC Terminations, and Provisionable Patchcords—Complete this procedure as needed to modify or delete generic communications channel (GCC) terminations, optical service channel (OSC) terminations, and provisionable patchcords.
11. G86 Convert a Pass-Through Connection to Add/Drop Connections—Complete this procedure as needed to convert a pass-through connection to an add/drop connection.
12. G87 Change Node Timing Parameters—Complete this procedure as needed.
13. G88 Modify Users and Change Security—Complete this procedure as needed to make changes to user settings, including security level and security policies, and to delete users.
14. G131 Convert DWDM Nodes to Hybrid Nodes—Complete this procedure as needed to convert a DWDM node to a hybrid node.
15. G89 Change SNMP Settings—Complete this procedure as needed.
NTP-G76 Verify Optical Span Loss Using CTC
Purpose
This procedure verifies the span loss between two DWDM nodes using Cisco Transport Controller (CTC). Perform this procedure after a node or network modification has occurred and you want to verify that the span loss between the nodes has not changed.
Tools/Equipment
None
Prerequisite Procedures
All procedures in Chapter 3, "Turn Up a Node."
Required/As Needed
As needed
Onsite/Remote
Onsite or remote
Security Level
Superuser
Note Using CTC to verify span loss is faster than a span loss measurement using an optical time domain reflectometer (OTDR) and does not require fibers to be removed. However, the resolution is not as precise as an OTDR measurement.
Step 1 Complete the "DLP-G46 Log into CTC" task. If you are already logged in, continue with Step 2.
Step 2 In node view (single-shelf mode) or multishelf view (multishelf mode), click the Provisioning > Comm Channels > OSC tabs. Verify that two OSC terminations are provisioned and have an In-Service and Normal (IS-NR) (ANSI) or Unlocked-enabled (ETSI) service state.
Step 3 Click the Maintenance > DWDM > WDM Span Check tabs.
Step 4 Click Retrieve Span Loss Values to retrieve the latest span loss data.
Step 5 View the following information:
•Side—Shows the side to which the span loss values apply, either east or west.
•Min Expected Span Loss (dBm)—Shows the expected minimum span loss (in dBm). You can change the minimum by entering a new value in the field.
•Meas Span Loss (dBm)—Shows the measured span loss (in dBm).
•Max Expected Span Loss (dBm)—Shows the expected maximum span loss (in dBm). You can change the minimum by entering a new value in the field.
Note The minimum and maximum expected span loss values are calculated by Cisco MetroPlanner and imported to the node when you perform the "NTP-G143 Import the Cisco MetroPlanner NE Update Configuration File" task on page 3-39.
•Resolution (dBm)—Shows the resolution of the span loss measurement (in dBm):
–+/- 1.5 dB for measured span losses between 0 and 25 dB
–+/- 2.5 dB for measured span losses between 25 and 38 dB
Step 6 If the measured span loss is not between the minimum and maximum expected span loss, contact your site planner for further instructions.
Stop. You have completed this procedure.
NTP-G77 Manage Automatic Power Control
Step 1 Complete the "DLP-G46 Log into CTC" task. If you are already logged in, continue with Step 2.
Step 2 Complete the following tasks as necessary:
• G157 Disable Automatic Power Control
• G158 Enable Automatic Power Control
• G159 Refresh Automatic Power Control Information
Stop. You have completed this procedure.
DLP-G157 Disable Automatic Power Control
Purpose
This task disables the DWDM APC.
Tools/Equipment
None
Prerequisite Procedures
Required/As Needed
As needed
Onsite/Remote
Onsite or remote
Security Level
Superuser
Caution Disable APC only to perform specific troubleshooting or node provisioning tasks. Always enable APC as soon as the tasks are completed. Leaving APC disabled can cause traffic loss.
Step 1 In node view (single-shelf mode) or multishelf view (multishelf mode), click the Maintenance > DWDM > APC tabs.
Step 2 Click Disable APC.
Step 3 In the confirmation dialog box, Click Yes.
Step 4 In the status area, verify that the Check APC State status changes to Disable.
Step 5 Return to your originating procedure (NTP).
DLP-G158 Enable Automatic Power Control
Purpose
This task enables the DWDM APC.
Tools/Equipment
None
Prerequisite Procedures
Required/As Needed
As needed
Onsite/Remote
Onsite or remote
Security Level
Superuser
Caution Disable APC only to perform specific troubleshooting or node provisioning tasks. Always enable APC as soon as the tasks are completed. Leaving APC disabled can cause traffic loss.
Step 1 In node view (single-shelf mode) or multishelf view (multishelf mode), click the Maintenance > DWDM > APC tabs.
Step 2 Click Enable APC.
Step 3 In the confirmation dialog box, Click Yes.
Step 4 In the status area, verify that the Check APC State status changes to Disable.
Step 5 Return to your originating procedure (NTP).
DLP-G159 Refresh Automatic Power Control Information
Step 1 In node view (single-shelf mode) or multishelf view (multishelf mode), click the Maintenance > DWDM > APC tabs.
Step 2 Click Refresh.
Step 3 Return to your originating procedure (NTP).
NTP-G78 View ROADM Node Power Equalization
Step 1 Complete the "DLP-G46 Log into CTC" task. If you are already logged in, continue with Step 2.
Step 2 In node view (single-shelf mode) or multishelf view (multishelf mode), click the Maintenance > DWDM > ROADM Power Monitoring tabs.
Step 3 On the Power Monitoring tab, view the following east-to-west (E > W) and west-to-east (W > E) power information:
•Padd—Add power. This power level is represented by the red bar.
•Ppt—Pass-through power. This power level is represented by the yellow bar.
•Pout—Output power. This power level is represented by the blue bar. It shows the per-channel (wavelength) power at the 32WSS output (COM_TX) port.
Note The 32WSS and 32WSS-L cards are designed to handle minor differences in output power. The output power does not need to be exactly the same for all wavelengths.
Figure 10-1 shows an example of ROADM node with equalized output power.
Figure 10-1 Equalized ROADM Power Example
Step 4 If needed, click Refresh to update the display.
Stop. You have completed this procedure.
NTP-G80 Change Node Management Information
Purpose
This procedure changes the node name, date, time, contact information, and login legal disclaimer.
Tools/Equipment
None
Prerequisite Procedures
NTP-G24 Set Up Name, Date, Time, and Contact Information, page 3-10
Required/As Needed
As needed
Onsite/Remote
Onsite or remote
Security Level
Provisioning or higher
Step 1 Complete the "DLP-G46 Log into CTC" task. If you are already logged in, continue with Step 2.
Step 2 Complete the "NTP-G103 Back Up the Database" procedure on page 13-2.
Step 3 In node view (single-shelf mode) or multishelf view (multishelf mode), click the Provisioning > General tabs.
Step 4 Complete the "DLP-G160 Change the Node Name, Date, Time, and Contact Information" task, as needed.
Step 5 Complete the "DLP-G161 Change the Login Legal Disclaimer" task, as needed.
Step 6 After confirming the changes, complete the "NTP-G103 Back Up the Database" procedure on page 13-2.
Stop. You have completed this procedure.
DLP-G160 Change the Node Name, Date, Time, and Contact Information
Caution Changing the date, time, or time zone might invalidate the node's performance monitoring counters.
Step 1 In node view (single-shelf mode) or multishelf view (multishelf mode), click the Provisioning > General tabs.
Step 2 Change any of the following:
•General: Node Name
•General: Contact
•Location: Latitude
•Location: Longitude
•Location: Description
Note To see changes to longitude or latitude on the network map, you must go to network view and right-click the specified node, then click Reset Node Position.
•Time: Use NTP/SNTP Server
•Time: NTP/SNTP Server IP Address (if Use NTP/SNTP Server is checked)
•Time: Date (M/D/Y)
•Time: Time (H:M:S)
•Time: Time Zone
•Time: Use Daylight Saving Time
•AIS-V Insertion On STS-1 Signal Degrade - Path: Insert AIS-V on STS-1 SD-P
•AIS-V Insertion On STS-1 Signal Degrade - Path: SD-P BER
See the "NTP-G24 Set Up Name, Date, Time, and Contact Information" procedure on page 3-10 for detailed field descriptions.
Step 3 Click Apply.
Step 4 Return to your originating procedure (NTP).
DLP-G161 Change the Login Legal Disclaimer
Step 1 In node view (single-shelf mode) or multishelf view (multishelf mode), click the Provisioning > Security > Legal Disclaimer > HTML tabs.
Step 2 The existing statement is a default, non-customer-specific disclaimer. If you want to edit this statement with specifics for your company, you can change the text. Use the HTML commands in Table 10-1 to format the text, as needed.
Step 3 If you want to preview your changed statement and formatting, click the Preview subtab.
Step 4 Click Apply.
Step 5 Return to your originating procedure (NTP).
NTP-G134 Modify OSI Provisioning
Note Additional information about the ONS 15454 implementation of OSI is provided in the "Management Network Connectivity" chapter of the Cisco ONS 15454 DWDM Reference Manual.
Step 1 Complete the "DLP-G46 Log into CTC" task. If you are already logged in, continue with Step 2.
Step 2 Complete the "NTP-G103 Back Up the Database" procedure on page 13-2.
Step 3 Perform any of the following tasks as needed:
• G284 Modify the TARP Operating Parameters
• DLP-G285 Add a Static TID to NSAP Entry to the TARP Data Cache, page 3-32
• G286 Remove a Static TID to NSAP Entry from the TARP Data Cache
• G287 Add a TARP Manual Adjacency Table Entry
• G292 Remove a TARP Manual Adjacency Table Entry
• G293 Change the OSI Routing Mode
• G294 Edit the OSI Router Configuration
• G295 Edit the OSI Subnetwork Point of Attachment
• G296 Edit an IP-Over-CLNS Tunnel
• G297 Delete an IP-Over-CLNS Tunnel
Step 4 Complete the "NTP-G103 Back Up the Database" procedure on page 13-2.
Stop. You have completed this procedure.
DLP-G284 Modify the TARP Operating Parameters
Step 1 In node view (single-shelf mode) or multishelf view (multishelf mode), click the Provisioning > OSI > TARP > Config tabs.
Step 2 Provision the following parameters, as needed:
•TARP PDUs L1 Propagation—If checked (default), TARP Type 1 PDUs that are received by the node and are not excluded by the LDB are propagated to other NEs within the Level 1 OSI area. (Type 1 PDUs request a protocol address that matches a target identifier [TID] within a Level 1 routing area.) The propagation does not occur if the NE is the target of the Type 1 PDU, and PDUs are not propagated to the NE from which the PDU was received.
Note The TARP PDUs L1 Propagation parameter is not used when the Node Routing Area (Provisioning > OSI > Main Setup tab) is set to End System.
•TARP PDUs L2 Propagation—If checked (default), TARP Type 2 PDUs received by the node that are not excluded by the LDB are propagated to other NEs within the Level 2 OSI areas. (Type 2 PDUs request a protocol address that matches a TID within a Level 2 routing area.) The propagation does not occur if the NE is the target of the Type 2 PDU, and PDUs are not propagated to the NE from which the PDU was received.
Note The TARP PDUs L2 Propagation parameter is only used when the Node Routing Area is provisioned to Intermediate System Level 1/Level 2.
•TARP PDUs Origination—If checked (default), the node performs all TARP origination functions including:
–TID to Network Service Access Point (NSAP) resolution requests (originate TARP Type 1 and Type 2 PDUs)
–NSAP to TID requests (originate Type 5 PDUs)
–TARP address changes (originate Type 4 PDUs)
Note TARP Echo and NSAP to TID are not supported.
•TARP Data Cache—If checked (default), the node maintains a TARP data cache (TDC). The TDC is a database of TID-to-NSAP pairs created from TARP Type 3 PDUs that are received by the node and modified by TARP Type 4 PDUs (TID-to-NSAP updates or corrections). TARP 3 PDUs are responses to Type 1 and Type 2 PDUs. The TDC can also be populated with static entries entered on the TARP > Static TDC tab.
Note This parameter is only used when the TARP PDUs Origination parameter is enabled.
•L2 TARP Data Cache—If checked (default), the TIDs and NSAPs of NEs originating Type 2 requests are added to the TDC before the node propagates the requests to other NEs.
Note The L2 TARP Data Cache parameter is designed for Intermediate System Level 1/Level 2 nodes that are connected to other Intermediate System Level 1/Level 2 nodes. Enabling the parameter for Intermediate System Level 1 nodes is not recommended.
•LDB—If checked (default), enables the TARP loop detection buffer. The LDB prevents TARP PDUs from being sent more than once on the same subnet.
Note The LDB parameter is not used if the Node Routing Mode is provisioned to End System or if the TARP PDUs L1 Propagation parameter is not enabled.
•LAN TARP Storm Suppression—If checked (default), enables TARP storm suppression. This function prevents redundant TARP PDUs from being unnecessarily propagated across the LAN network.
•Send Type 4 PDU on Startup—If checked, a TARP Type 4 PDU is originated during the initial ONS 15454 startup. Type 4 PDUs indicate that a TID or NSAP change has occurred at the NE. (The default setting is not enabled.)
•Type 4 PDU Delay—Sets the amount of time that will pass before the Type 4 PDU is generated when Send Type 4 PDU on Startup is enabled. 60 seconds is the default. The range is 0 to 255 seconds.
Note The Send Type 4 PDU on Startup and Type 4 PDU Delay parameters are not used if the TARP PDUs Origination parameter is not enabled.
•LDB Entry—Sets the TARP loop detection buffer timer. The LDB buffer time is assigned to each LDB entry for which the TARP sequence number (tar-seq) is zero. The default is 5 minutes. The range is 1 to 10 minutes.
•LDB Flush—Sets the frequency period for flushing the LDB. The default is 5 minutes. The range is 0 to 1440 minutes.
•T1—Sets the amount of time to wait for a response to a Type 1 PDU. Type 1 PDUs seek a specific NE TID within an OSI Level 1 area. The default is 15 seconds. The range is 0 to 3600 seconds.
•T2—Sets the amount of time to wait for a response to a Type 2 PDU. TARP Type 2 PDUs seek a specific NE TID value within OSI Level 1 and Level 2 areas. The default is 25 seconds. The range is 0 to 3600 seconds.
•T3—Sets the amount of time to wait for an address resolution request. The default is 40 seconds. The range is 0 to 3600 seconds.
•T4—Sets the amount of time to wait for an error recovery. This timer begins after the T2 timer expires without finding the requested NE TID. The default is 20 seconds. The range is 0 to 3600 seconds.
Note The T1, T2, and T4 timers are not used if TARP PDUs Origination is not enabled.
Step 3 Click Apply.
Step 4 Return to your originating procedure (NTP).
DLP-G286 Remove a Static TID to NSAP Entry from the TARP Data Cache
Step 1 In node view (single-shelf mode) or multishelf view (multishelf mode), click the Provisioning > OSI > TARP > Static TDC tabs.
Step 2 Click the static entry that you want to delete.
Step 3 Click Delete Static Entry.
Step 4 In the Delete TDC Entry dialog box, click Yes.
Step 5 Return to your originating procedure (NTP).
DLP-G287 Add a TARP Manual Adjacency Table Entry
Step 1 In the node view (single-shelf mode) or multishelf view (multishelf mode), click the Provisioning > OSI > TARP > MAT tabs.
Step 2 Click Add.
Step 3 In the Add TARP Manual Adjacency Table Entry dialog box, enter the following:
•Level—Sets the TARP Type Code that will be sent:
–Level 1—Indicates that the adjacency is within the same area as the current node. The entry generates Type 1 PDUs.
–Level 2—Indicates that the adjacency is in a different area from the current node. The entry generates Type 2 PDUs.
•NSAP—Enter the OSI NSAP address in the NSAP field or, if preferred, click Use Mask and enter the address in the Masked NSAP Entry dialog box.
Step 4 Click OK to close the Masked NSAP Entry dialog box, if used, and then click OK to close the Add Static Entry dialog box.
Step 5 Return to your originating procedure (NTP).
DLP-G292 Remove a TARP Manual Adjacency Table Entry
Purpose
This task removes an entry from the TARP MAT.
Tools/Equipment
None
Prerequisite Procedures
Required/As Needed
As needed
Onsite/Remote
Onsite or remote
Security Level
Provisioning or higher
Caution If TARP manual adjacency is the only means of communication to a group of nodes, loss of visibility will occur when the adjacency table entry is removed.
Step 1 In node view (single-shelf mode) or multishelf view (multishelf mode), click the Provisioning > OSI > TARP > MAT tabs.
Step 2 Click the MAT entry that you want to delete.
Step 3 Click Remove.
Step 4 In the Delete TDC Entry dialog box, click OK.
Step 5 Return to your originating procedure (NTP).
DLP-G293 Change the OSI Routing Mode
Purpose
This task changes the OSI routing mode.
Tools/Equipment
None
Prerequisite Procedures
Required/As Needed
As needed
Onsite/Remote
Onsite or remote
Security Level
Provisioning or higher
Caution Do not complete this procedure until you confirm the role of the node within the network. It will be either an ES, IS Level 1, or IS Level 1/Level 2. This decision must be carefully considered. For additional information about OSI provisioning, refer to the "Management Network Connectivity" chapter of the Cisco ONS 15454 DWDM Reference Manual.
Caution Link state PDU (LSP) buffers must be the same at all NEs within the network, or loss of visibility could occur. Do not modify the LSP buffers unless you are sure that all NEs within the OSI have the same buffer size.
Caution LSP buffer sizes cannot be greater than the LAP-D MTU size within the OSI area.
Step 1 Verify the following:
•All L1/L2 virtual routers on the NE must reside in the same area. This means that all neighboring virtual routers must have at least one common area address.
•For OSI L1/L2 to ES routing mode changes, only one L1/L2 virtual router and no more than one subnet can be configured.
•For OSI L1 to ES routing mode changes, only one L1 virtual router and no more than one subnet can be configured.
Step 2 In node view (single-shelf mode) or multishelf view (multishelf mode), click the Provisioning > OSI > Main Setup tabs.
Step 3 Choose one of the following node routing modes:
•End System—The ONS 15454 performs OSI IS functions. It communicates with IS and ES nodes that reside within its OSI area. It depends upon an IS L1/L2 node to communicate with IS and ES nodes that reside outside its OSI area.
•Intermediate System Level 1—The ONS 15454 performs IS functions. It communicates with IS and ES nodes that reside within its OSI area. It does not communicate with IS nodes that reside in other OSI areas except through an IS L1/L2 node residing in its own area.
•Intermediate System Level 1/Level 2—The ONS 15454 performs IS functions. It communicates with IS and ES nodes that reside within its OSI area. It also communicates with IS L1/L2 nodes that reside in other OSI areas. Before choosing this option, verify the following:
–The node is connected to another IS Level 1/Level 2 node that resides in a different OSI area.
–The node is connected to all nodes within its area that are provisioned as IS L1/L2.
Note Changing a routing mode should be carefully considered. Additional information about OSI ESs and ISs and the ES-IS and IS-IS protocols are provided in the "Management Network Connectivity" chapter of the Cisco ONS 15454 DWDM Reference Manual.
Step 4 Although Cisco does not recommend changing the LSP buffer sizes, you can adjust the buffers in the following fields:
•L1 LSP Buffer Size—Adjusts the Level 1 link state PDU buffer size.
•L2 LSP Buffer Size—Adjusts the Level 2 link state PDU buffer size.
Step 5 Return to your originating procedure (NTP).
DLP-G294 Edit the OSI Router Configuration
Step 1 Click the Provisioning > OSI > Routers > Setup tabs.
Step 2 Choose the router you want provision and click Edit.
Step 3 In the OSI Router Editor dialog box:
a. Check or uncheck the Enabled box to enable or disable the router.
Note Router 1 must be enabled before you can enable Routers 2 and 3.
b. For enabled routers, edit the primary area address, if needed. The address can be between 8 and 24 alphanumeric characters in length.
c. If you want to add or edit an area address to the primary area, enter the address at the bottom of the Multiple Area Addresses area. The area address can be 2 to 26 numeric characters (0-9) in length. Click Add.
d. Click OK.
Step 4 Return to your originating procedure (NTP).
DLP-G295 Edit the OSI Subnetwork Point of Attachment
Step 1 If the subnet router is not enabled, complete "DLP-G294 Edit the OSI Router Configuration" task to enable it. If it is enabled, continue with Step 2.
Step 2 In the node view (single-shelf mode) or multishelf view (multishelf mode), click the Provisioning > OSI > Routers > Subnet tabs.
Step 3 Choose the subnet you want to edit, then click Edit.
Step 4 In the Edit <subnet type> Subnet <slot/port> dialog box, edit the following fields:
•ESH—The End System Hello (ESH) PDU propagation frequency. An end system NE transmits ESHs to inform other ESs and ISs about the NSAPs it serves. The default is 10 seconds. The range is 10 to 1000 seconds.
•ISH—The Intermediate System Hello (ISH) PDU propagation frequency. An intermediate system NE sends ISHs to other ESs and ISs to inform them about the NEs it serves. The default is 10 seconds. The range is 10 to 1000 seconds.
•IIH—The Intermediate System to Intermediate System Hello (IIH) PDU propagation frequency. The IS-IS Hello PDUs establish and maintain adjacencies between ISs. The default is 3 seconds. The range is 1 to 600 seconds.
Note The IS-IS Cost and DIS Priority parameters are provisioned when you create or enable a subnet. You cannot change the parameters after the subnet is created. To change the DIS Priority and IS-IS Cost parameters, delete the subnet and create a new one.
Step 5 Click OK.
Step 6 Return to your originating procedure (NTP).
DLP-G296 Edit an IP-Over-CLNS Tunnel
Purpose
This task allows you to edit the parameters of an IP-over-CLNS tunnel.
Tools/Equipment
None
Prerequisite Procedures
DLP-G291 Create an IP-Over-CLNS Tunnel, page 3-36
Required/As Needed
As needed
Onsite/Remote
Onsite or remote
Security Level
Provisioning or higher
Caution Changing the IP or NSAP addresses or an IP-over-CLNS tunnel can cause loss of NE visibility or NE isolation. Do not change network addresses until you verify the changes with your network administrator.
Step 1 Click the Provisioning > OSI > Tunnels tabs.
Step 2 Click Edit.
Step 3 In the Edit IP Over OSI Tunnel dialog box, complete the following fields:
•Tunnel Type—Edit the tunnel type:
–Cisco—Creates the proprietary Cisco IP tunnel. Cisco IP tunnels add the CLNS header to the IP packets.
–GRE—Creates a generic routing encapsulation (GRE). GRE tunnels add the CLNS header and a GRE header to the IP packets.
The Cisco proprietary tunnel is slightly more efficient than the GRE tunnel because it does not add the GRE header to each IP packet. The two tunnel types are not compatible. Most Cisco routers support the Cisco IP tunnel, while only a few support both GRE and Cisco IP tunnels. You generally should create Cisco IP tunnels if you are tunneling between two Cisco routers or between a Cisco router and an ONS node.
Caution Always verify that the IP-over-CLNS tunnel type you choose is supported by the equipment at the other end of the tunnel.
•IP Address—Enter the IP address of the IP-over-CLNS tunnel destination.
•IP Mask—Enter the IP address subnet mask of the IP-over-CLNS destination.
•OSPF Metric—Enter the Open Shortest Path First (OSPF) metric for sending packets across the IP-over-CLNS tunnel. The OSPF metric, or cost, is used by OSPF routers to calculate the shortest path. The default is 110. Normally, it is not changed unless you are creating multiple tunnel routes and want to prioritize routing by assigning different metrics.
•NSAP Address—Enter the destination NE or OSI router NSAP address.
Step 4 Click OK.
Step 5 Return to your originating procedure (NTP).
DLP-G297 Delete an IP-Over-CLNS Tunnel
Caution Deleting an IP-over-CLNS tunnel might cause the nodes to lose visibility or cause node isolation. If node isolation occurs, onsite provisioning might be required to regain connectivity. Always confirm tunnel deletions with your network administrator.
Step 1 Click the Provisioning > OSI > Tunnels tabs.
Step 2 Choose the IP-over-CLNS tunnel that you want to delete.
Step 3 Click Delete.
Step 4 Click OK.
Step 5 Return to your originating procedure (NTP).
NTP-G81 Change CTC Network Access
Note Additional ONS 15454 networking information, including IP addressing examples, dual IP addressing (secure mode) information, static route scenarios, OSPF protocol information, and Routing Information Protocol (RIP) options are provided in the "Management Network Connectivity" chapter in the Cisco ONS 15454 DWDM Reference Manual.
Step 1 Complete the "DLP-G46 Log into CTC" task. If you are already logged in, continue with Step 2.
Step 2 Complete the "NTP-G103 Back Up the Database" procedure on page 13-2.
Step 3 Perform any of the following tasks as needed:
• G266 Modify Backplane Port IP Settings in Security Mode
• G267 Disable Node Security Mode
• DLP-G59 Set Up or Change Open Shortest Path First Protocol, page 3-21
• G167 Delete a Firewall Tunnel
Step 4 Complete the "NTP-G103 Back Up the Database" procedure on page 13-2.
Stop. You have completed this procedure.
DLP-G162 Change IP Settings
Caution Changing the node IP address, subnet mask, or IIOP listener port causes the TCC2/TCC2P cards to reboot. If Ethernet circuits using Spanning Tree Protocol (STP) originate or terminate on E-Series Ethernet cards installed in the node, circuit traffic will be lost for several minutes while the spanning trees reconverge. Other circuits are not affected by TCC2/TCC2P reboots.
Note If the node contains TCC2P cards and is in default (repeater) mode, the node IP address refers to the TCC2P front-access TCP/IP (LAN) port as well as the backplane LAN port. If the node is in secure mode, this task only changes the front-access port IP address only. If the node is in secure mode and has been locked, the IP address cannot be changed unless the lock is removed by Cisco Technical Support.
Step 1 In node view (single-shelf mode) or multishelf view (multishelf mode), click the Provisioning > Network > General tabs.
Step 2 Change any of the following, as required:
•IP Address
•Net/Subnet Mask Length
•Default Router
•LCD Setting
•Suppress CTC IP Display
•Forward DHCP Request To
Gateway Settings
•Enable SOCKS proxy on Port. If enabled, one of the following:
–External Network Element
–Gateway Network Element
–SOCK Proxy only
See the "DLP-G56 Provision IP Settings" task on page 3-14 for detailed field descriptions.
Step 3 Click Apply.
If you changed a network field that will cause the node to reboot, such as the IP address, or subnet mask, the Change Network Configuration confirmation dialog box appears. If you changed a gateway setting, a confirmation appropriate to the gateway field appears.
Step 4 If a confirmation dialog box appears, click Yes.
If you changed an IP address, subnet mask length, both ONS 15454 TCC2/TCC2P cards reboot, one at a time. A TCC2/TCC2P card reboot causes a temporary loss of connectivity to the node, but traffic is unaffected.
Step 5 Confirm that the changes appear on the Provisioning > Network > General tabs. If not, refer to the Cisco ONS 15454 DWDM Troubleshooting Guide.
Step 6 Return to your originating procedure (NTP).
DLP-G265 Lock Node Security
Caution When a node is locked, it cannot be unlocked by any user or action. It can only be changed by Cisco Technical Support. Even if the node's database is deleted and another unlocked database is loaded, the node will remain locked. Do not proceed unless you want the node to permanently retain the current secure configuration including dual IP addresses.
Note The options in this task are available only when TCC2P cards are installed.
Step 1 In node view (single-shelf mode) or multishelf view (multishelf mode), click the Provisioning > Security > Data Comm tabs.
Step 2 Click Lock.
Step 3 In the Confirm Lock Secure Mode dialog box, click Yes.
Step 4 Return to your originating procedure (NTP).
DLP-G266 Modify Backplane Port IP Settings in Security Mode
Purpose
This task modifies the ONS 15454 backplane IP address, subnet mask, and default router when security mode is enabled. It also modifies settings that control backplane IP address visibility in CTC and the ONS 15454 LCD.
Tools/Equipment
TCC2P cards must be installed.
Prerequisite Procedures
NTP-G103 Back Up the Database, page 13-2
Required/As Needed
As needed
Onsite/Remote
Onsite or remote
Security Level
Superuser
Caution Provisioning an IP address that is incompatible with the ONS 15454 network might be service affecting.
Caution This task cannot be performed on a secure mode NE that has been locked.
Note The options in this task are available only when TCC2P cards are installed.
Step 1 Click the Provisioning > Security > Data Comm tabs.
Step 2 Modify the following fields, as necessary:
•IP Address
•Subnet Mask
•Default Router
•LCD IP Setting—choose one of the following:
–Allow Configuration—Displays the backplane IP address on the LCD and allows it to be changed using the LCD buttons.
–Display only—Displays the backplane IP address on the LCD but does not allow it to be changed using the LCD buttons.
–Suppress Display—Suppresses the display of the IP address on the LCD.
•Suppress CTC IP Address—If checked, suppresses the IP address from display on the Data Comm subtab, CTC node view or multishelf view information area, and other locations.
Step 3 Click Apply.
If you changed the IP address, subnet mask, or default router, the node will reboot. This will take 5 to 10 minutes.
Step 4 Return to your originating procedure (NTP).
DLP-G267 Disable Node Security Mode
Note The node will reboot after you complete this task, causing a temporary disconnection between the CTC computer and the node.
Note If you change an NE from secure mode to the default (repeater) mode, the backplane IP address becomes the node IP address.
Note This task cannot be performed if the NE's security mode configuration is locked. If secure mode is locked, you must contact Cisco Technical Support to change the node configuration.
Note The options in this task are only available when TCC2P cards are installed.
Step 1 Click the Provisioning > Security > Data Comm tabs.
Step 2 Click Change Mode.
Step 3 Review the information on the Change Secure Mode wizard page, then click Next.
Step 4 On the Node IP Address page, choose the address you want to assign to the node:
•Backplane Ethernet Port—Assigns the backplane IP address as the node IP address.
•TCC Ethernet Port—Assigns the TCC2P port IP address as the node IP address.
•New IP Address—Allows you to define a new IP address. If you choose this option, enter the new IP address, subnet mask, and default router IP address.
Step 5 Click Next.
Step 6 On the SOCKS Proxy Server Settings page, choose one of the following:
•External Network Element (ENE)—If selected, SOCKS proxy will be disabled by default, and the CTC computer is only visible to the ONS 15454 where the CTC computer is connected. The computer is not visible to the secure mode data communications channel (DCC)-connected nodes. Firewall is enabled, which means that the node prevents IP traffic from being routed between the DCC and the LAN port.
•Gateway Network Element (GNE)—If selected, the CTC computer is visible to other DCC-connected nodes and SOCKS proxy remains enabled. However, the node prevents IP traffic from being routed between the DCC and the LAN port.
•Proxy-only—If selected, the ONS 15454 responds to CTC requests with a list of DCC-connected nodes within the firewall for which the node serves as a proxy. The CTC computer is visible to other DCC-connected nodes. The node does not prevent traffic from being routed between the DCC and LAN port.
Step 7 Click Finish.
Within the next 30 to 40 seconds, the TCC2P cards reboot. CTC switches to network view, and the CTC Alerts dialog box appears. In network view, the node changes to gray and a DISCONNECTED condition appears.
Step 8 In the CTC Alerts dialog box, click Close. Wait for the reboot to finish. (This might take several minutes.)
Step 9 Return to your originating procedure (NTP).
DLP-G163 Modify a Static Route
Step 1 In node view (single-shelf mode) or multishelf view (multishelf mode), click the Provisioning > Network tabs.
Step 2 Click the Static Routing tab.
Step 3 Click the static route you want to edit.
Step 4 Click Edit.
Step 5 In the Edit Selected Static Route dialog box, enter the following:
•Mask
•Next Hop
•Cost
See the "DLP-G58 Create a Static Route" task on page 3-20 for detailed field descriptions.
Step 6 Click OK.
Step 7 Return to your originating procedure (NTP).
DLP-G164 Delete a Static Route
Step 1 In node view (single-shelf mode) or multishelf view (multishelf mode), click the Provisioning > Network > Static Routing tabs.
Step 2 Click the static route that you want to delete.
Step 3 Click Delete. A confirmation dialog box appears.
Step 4 Click Yes.
Step 5 Return to your originating procedure (NTP).
DLP-G165 Disable OSPF
Purpose
This task disables the OSPF routing protocol process for an ONS 15454 LAN.
Tools/Equipment
None
Prerequisite Procedures
DLP-G59 Set Up or Change Open Shortest Path First Protocol, page 3-21
Required/As Needed
As needed
Onsite/Remote
Onsite or remote
Security Level
Provisioning or higher
Step 1 In node view (single-shelf mode) or multishelf view (multishelf mode), click the Provisioning > Network > OSPF tabs. The OSPF subtab has several options.
Step 2 In the OSPF on LAN area, uncheck the OSPF active on LAN check box.
Step 3 Click Apply. Confirm that the changes appear.
Step 4 Return to your originating procedure (NTP).
DLP-G167 Delete a Firewall Tunnel
Purpose
This task removes a firewall tunnel.
Tools/Equipment
None
Prerequisite Procedures
Required/As Needed
As needed
Onsite/Remote
Onsite or remote
Security Level
Superuser
Step 1 Click the Provisioning > Network > Firewall subtabs.
Step 2 Click the firewall tunnel that you want to delete.
Step 3 Click Delete.
Step 4 Return to your originating procedure (NTP).
NTP-G82 Customize the CTC Network View
Step 1 Complete the "DLP-G46 Log into CTC" task. If you are already logged in, continue with Step 2.
Step 2 Complete the following tasks, as needed:
• G168 Change the Network View Background Color
• G169 Change the Default Network View Background Map
• G170 Apply a Custom Network View Background Map
• G173 Enable Dialog Box Do-Not-Display Option
• G174 Switch Between TDM and DWDM Network Views
• G330 Consolidate Links in Network View
Stop. You have completed this procedure.
DLP-G168 Change the Network View Background Color
Note If you modify background colors, the change is stored in your CTC user profile on the computer. The change does not affect other CTC users.
Step 1 From the View menu in CTC, choose Go to Network View.
Step 2 If you want to change a domain background, double-click the domain. If not, continue with Step 3.
Step 3 Right-click the network view or domain map area and choose Set Background Color from the shortcut menu.
Step 4 In the Choose Color dialog box, select a background color.
Step 5 Click OK.
Step 6 Return to your originating procedure (NTP).
DLP-G169 Change the Default Network View Background Map
Purpose
This task changes the default map of the CTC network view.
Tools/Equipment
None
Prerequisite Procedures
Required/As Needed
As needed
Onsite/Remote
Onsite or remote
Security Level
Superuser
Note If you modify the background image, the change is stored in your CTC user profile on the computer. The change does not affect other CTC users.
Step 1 From the Edit menu, choose Preferences > Map and check the Use Default Map check box.
Step 2 Click Apply.
Step 3 Click OK. Verify that the United States map is displayed.
Step 4 In network view, double-click any node on the map.
Step 5 In node view (single-shelf mode) or multishelf view (multishelf mode), click the Provisioning > Defaults tabs. Wait for the Defaults selector frame to load the defaults. This could take a few minutes.
Step 6 In the Defaults Selector area, choose CTC and then network. (You might have to scroll down on the list to find "network.")
Step 7 Click the Default Value field and choose a default map from the drop-down list. Map choices are Germany, Japan, Netherlands, South Korea, United Kingdom, and the United States.
Step 8 Click Apply.
Step 9 Click OK.
Step 10 From the View menu, select Go to Network View. Confirm that the new map is displayed.
Step 11 If the ONS 15454 icons are not visible, right-click the network view and choose Zoom Out. Repeat until all the ONS 15454 icons are visible. (You can also choose Fit Graph to Window.)
Step 12 If you need to reposition the node icons, drag and drop them one at a time to a new location on the map.
Step 13 If you want to change the magnification of the icons, right-click the network view and choose Zoom In. Repeat until the ONS 15454 icons are displayed at the magnification you want.
Step 14 Return to your originating procedure (NTP).
DLP-G170 Apply a Custom Network View Background Map
Note You can replace the network view background image with any JPEG or GIF image that is accessible on a local or network drive. If you apply a custom background image, the change is stored in your CTC user profile on the computer. The change does not affect other CTC users.
Step 1 From the Edit menu, choose Preferences > Map and uncheck the Use Default Map check box.
Step 2 From the View menu, choose Go to Network View.
Step 3 Right-click the network or domain map and choose Set Background Image.
Step 4 Click Browse. Navigate to the graphic file you want to use as a background.
Step 5 Select the file. Click Open.
Step 6 Click Apply and then click OK.
Step 7 If the ONS 15454 icons are not visible, right-click the network view and choose Zoom Out. Repeat this step until all the ONS 15454 icons are visible.
Step 8 If you need to reposition the node icons, drag and drop them one at a time to a new location on the map.
Step 9 If you want to change the magnification of the icons, right-click the network view and choose Zoom In. Repeat until the ONS 15454 icons are displayed at the magnification you want.
Step 10 Return to your originating procedure (NTP).
DLP-G171 Create Domain Icons
Note To allow users of any security level to create local domains, that is, domains that are visible on the home CTC session only, superusers can change the CTC.network.LocalDomainCreationAndViewing NE default value to TRUE. A TRUE value means any user can maintain the domain information in his or her Preferences file, meaning domain changes will not affect other CTC sessions. (The default value is FALSE, meaning domain information affects all CTC sessions and only superusers can create a domain or put a node into a domain.) See the "NTP-G135 Edit Network Element Defaults" procedure on page 13-42 to change NE default values.
Step 1 From the View menu, choose Go to Network View.
Step 2 Right-click the network map and choose Create New Domain from the shortcut menu.
Step 3 When the domain icon appears on the map, click the map name and type the domain name.
Step 4 Press Enter.
Step 5 Return to your originating procedure (NTP).
DLP-G172 Manage Domain Icons
Note To allow users of any security level to create local domains, that is, domains that are visible on the home CTC session only, superusers can change the CTC.network.LocalDomainCreationAndViewing NE default value to TRUE. A TRUE value means any user can maintain the domain information in his or her Preferences file, meaning domain changes will not affect other CTC sessions. (The default value is FALSE, meaning domain information affects all CTC sessions and only superusers can create a domain or put a node into a domain.) See the "NTP-G135 Edit Network Element Defaults" procedure on page 13-42 to change NE default values.
Step 1 From the View menu, choose Go to Network View.
Step 2 Locate the domain action that you want to perform in Table 10-2 and complete the appropriate steps.
Step 3 Return to your originating procedure (NTP).
DLP-G173 Enable Dialog Box Do-Not-Display Option
Note If any user who has rights to perform an operation (for example, creating a circuit) selects the "Do not show this message again" check box in a dialog box, the dialog box is not displayed for any other users who perform that operation on the network from the same computer unless the command is overridden using the following task. (The preference is stored on the computer, not in the node database.)
Step 1 From the Edit menu, choose Preferences.
Step 2 In the Preferences dialog box, click the General tab.
The Preferences Management area field lists all dialog boxes where "Do not show this message again" is enabled.
Step 3 Choose one of the following options, or uncheck the individual dialog boxes that you want to appear:
•Don't Show Any—Hides all do-not-display check boxes.
•Show All—Overrides do-not-display check box selections and displays all dialog boxes.
Step 4 Click OK.
Step 5 Return to your originating procedure (NTP).
DLP-G174 Switch Between TDM and DWDM Network Views
Step 1 From the View menu, choose Go to Network View.
Step 2 From the Network Scope drop-down list on the toolbar, choose one of the following:
•All—Displays both TDM and DWDM nodes.
•TDM—Displays only ONS 15454s with SONET or SDH cards including the transponder (TXP) and muxponder (MSP) cards.
•DWDM—Displays only ONS 15454s with DWDM cards, including the TXP and MXP cards.
Step 3 Return to your originating procedure (NTP).
DLP-G330 Consolidate Links in Network View
Note Global consolidation persists when CTC is re-launched but local consolidation does not persist.
Step 1 From the View menu, choose Go to Network View. CTC shows the link icons by default.
Step 2 Perform the following steps as needed:
•To toggle between the links, go to Step 3.
•To consolidate all the links on the network map, go to Step 4.
•To consolidate a link or links between two nodes, go to Step 5.
•To view information about a consolidated link, go to Step 6.
•To access an individual link within a consolidated link, go to Step 7.
•To expand consolidated links, go to Step 8.
•To filter the links by class, go to Step 9.
Step 3 Right-click on the network map and choose Show Link Icons to toggle the link icons on and off.
Step 4 To consolidate all the links on the network map (global consolidation):
a. Right-click anywhere on the network map.
b. Choose Collapse/Expand Links from the shortcut menu. The Collapse/Expand Links dialog window appears.
c. Select the check boxes for the link classes you want to consolidate.
d. Click OK. The selected link classes are consolidated throughout the network map.
Step 5 To consolidate a link or links between two nodes (local consolidation):
a. Right-click the link on the network map.
b. Choose Collapse Link from the shortcut menu. The selected link type consolidates to show only one link.
Note The links consolidate by class. For example, if you select a DCC link for consolidation only the DCC links will consolidate, leaving any other link classes expanded.
Figure 10-2 shows the network view with unconsolidated DCC and PPC links.
Figure 10-2 Unconsolidated Links in the Network View
Figure 10-3 shows a network view with globally consolidated links.
Figure 10-3 Consolidated Links in the Network View
Figure 10-4 shows a network view with local DCC link consolidation between two nodes.
Figure 10-4 Network View with Local Link Consolidation
Step 6 To view information about a consolidated link, either move your mouse over the link (the tooltip displays the number of links and the link class) or single-click the link to display detailed information on the left side of the window.
Step 7 To access an individual link within a consolidated link (for example, if you need to perform a span upgrades):
a. Right-click the consolidated link. A shortcut menu appears with a list of the individual links.
b. Hover the mouse over the selected link. A cascading menu appears where you can select an action for the individual link or navigate to one of the nodes where the link is attached.
Step 8 To expand locally consolidated links, right-click the consolidated link and choose Expand [link class] Links from the shortcut menu, where "link class" is DCC, PPC, etc.
Step 9 To filter the links by class:
a. Click the Link Filter button in the upper right area of the window. The Link Filter dialog appears.
The link classes that appear in the Link Filter dialog are determined by the Network Scope you choose in the network view ( Table 10-3).
Table 10-3 Link Classes By Network Scope
Network Scope Displayed Link ClassesALL
DCC, GCC, OTS, PPC, Server Trail
DWDM
GCC, OTS, PPC
TDM
DCC, PPC
b. Check the check boxes next to the links you want to display.
c. Click OK.
Step 10 Return to your originating procedure (NTP).
NTP-G83 Modify or Delete Card Protection Settings
Caution Modifying and deleting protection groups can be service affecting.
Step 1 Complete the "DLP-G46 Log into CTC" task. If you are already logged in, continue with Step 2.
Step 2 Perform any of the following tasks as needed:
• G175 Modify a Y-Cable Protection Group
• G176 Modify a Splitter Protection Group
• G177 Delete a Y-Cable Protection Group
Step 3 Complete the "NTP-G103 Back Up the Database" procedure on page 13-2.
Stop. You have completed this procedure.
DLP-G175 Modify a Y-Cable Protection Group
Purpose
This task modifies a Y-cable protection group that has been created for two TXP or MXP card client ports.
Tools/Equipment
None
Prerequisite Procedures
G33 Create a Y-Cable Protection Group
Required/As Needed
As needed
Onsite/Remote
Onsite or remote
Security Level
Provisioning or higher
Step 1 In node view (single-shelf mode) or shelf view (multishelf mode), click the Provisioning > Protection tabs.
Step 2 In the Protection Groups area, click the Y-cable protection group that you want to modify.
Step 3 Click Edit.
Step 4 In the Selected Group area, you can modify the following, as needed:
•Name—Type the changes to the protection group name. The name can have up to 32 alphanumeric characters.
•Revertive—Check this box if you want traffic to revert to the working card after failure conditions stay corrected for the amount of time chosen from the Reversion Time list. Uncheck this box if you do not want traffic to revert.
•Reversion time—If the Revertive check box is selected, choose the reversion time from the Reversion time drop-down list. The range is 0.5 to 12.0 minutes. The default is 5.0 minutes. This is the amount of time that will elapse before the traffic reverts to the working card. Traffic can revert when conditions causing the switch are cleared.
Step 5 Click OK. Confirm that the changes appear.
Step 6 Return to your originating procedure (NTP).
DLP-G176 Modify a Splitter Protection Group
Step 1 In node view (single-shelf mode) or shelf view (multishelf mode), click the Provisioning > Protection tabs.
Step 2 In the Protection Groups area, click the splitter protection group that you want to modify.
Step 3 Click Edit.
Step 4 In the Selected Group area, you can modify the following, as needed:
•Name—Type the changes to the protection group name. The name can have up to 32 alphanumeric characters.
•Revertive—Check this box if you want traffic to revert to the working card after failure conditions stay corrected for the amount of time chosen from the Reversion Time list. Uncheck this box if you do not want traffic to revert.
•Reversion time—If the Revertive check box is selected, choose the reversion time from the Reversion time drop-down list. The range is 0.5 to 12.0 minutes. The default is 5.0 minutes. This is the amount of time that will elapse before the traffic reverts to the working card. Traffic can revert when conditions causing the switch are cleared.
Step 5 Click OK. Confirm that the changes appear.
Step 6 Return to your originating procedure (NTP).
DLP-G177 Delete a Y-Cable Protection Group
Purpose
This task deletes a Y-cable protection group.
Tools/Equipment
None
Prerequisite Procedures
Required/As Needed
As needed
Onsite/Remote
Onsite or remote
Security Level
Provisioning or higher
Step 1 In node view (single-shelf mode) or shelf view (multishelf mode), click the Provisioning > Protection tabs.
Step 2 In the Protection Groups area, click the protection group you want to delete.
Step 3 Click Delete.
Step 4 Click Yes in the Delete Protection Group dialog box. Confirm that the changes appear.
Step 5 Return to your originating procedure (NTP).
NTP-G84 Initiate and Clear Y-Cable and Splitter External Switching Commands
Purpose
This procedure describes how to apply and remove Manual and Force protection switches on Y-cable and splitter protection groups. It also describes how to apply and remove a Lock On or Lock Out protection command to a Y-cable protection group.
Tools/Equipment
None
Prerequisite Procedures
NTP-G32 Install the Transponder and Muxponder Cards, page 3-51
Required/As Needed
As needed
Onsite/Remote
Onsite
Security Level
Superuser
Note Splitter protection groups are automatically created when you install a TXPP_MR_2.5G or MXPP_MR_2.5G card.
Step 1 Complete the "DLP-G46 Log into CTC" task. If you are already logged in, continue with Step 2.
Step 2 To perform a Manual protection switch, complete the "DLP-G178 Apply a Manual Y-Cable or Splitter Protection Switch" task.
Step 3 To perform a Force protection switch, complete the "DLP-G179 Apply a Force Y-Cable or Splitter Protection Switch" task.
Step 4 To clear a Force or Manual protection switch, complete the "DLP-G180 Clear a Manual or Force Y-Cable or Splitter Protection Switch" task.
Step 5 To prevent traffic on a working or protect card from switching to the other card in the pair, complete the "DLP-G181 Apply a Lock-On" task.
Step 6 To prevent traffic from switching to the protect card, complete the "DLP-G182 Apply a Lockout" task.
Step 7 To remove a lock-on or lockout and return a protection group to its usual switching method, complete the "DLP-G183 Clear a Lock-On or Lockout" task.
Stop. You have completed this procedure.
DLP-G178 Apply a Manual Y-Cable or Splitter Protection Switch
Caution A Manual switch will move traffic from the active to the standby card only if network conditions permit it. If conditions change during the switch, CTC will attempt to place traffic back on the original active card.
Step 1 In node view (single-shelf mode) or shelf view (multishelf mode), click the Maintenance > Protection tabs.
Step 2 In the Protection Groups list, click the Y-cable or splitter protection group where you want to apply the Manual protection switch.
Step 3 In the Selected Group area, click the active card or port.
Step 4 In the Switch Commands drop-down list, click Manual.
Step 5 In the Confirm Manual Operation dialog box, click Yes.
If conditions permit, the Manual switch will be applied. To clear the Manual switch, see the "DLP-G180 Clear a Manual or Force Y-Cable or Splitter Protection Switch" task.
Step 6 Return to your originating procedure (NTP).
DLP-G179 Apply a Force Y-Cable or Splitter Protection Switch
Caution A Force switch will move traffic from the active to the standby card or port immediately, regardless of network conditions. The switch will remain in effect until it is cleared.
Step 1 In node view (single-shelf mode) or shelf view (multishelf mode), click the Maintenance > Protection tabs.
Step 2 In the Protection Groups list, click the Y-cable or splitter protection group where you want to apply the Force protection switch.
Step 3 In the Selected Group area, click the active card or port.
Step 4 In the Switch Commands drop-down list, click Force.
Step 5 In the Confirm Manual Operation dialog box, click Yes.
The Force switch will be applied. To clear the Force switch, see the "DLP-G180 Clear a Manual or Force Y-Cable or Splitter Protection Switch" task.
Step 6 Return to your originating procedure (NTP).
DLP-G180 Clear a Manual or Force Y-Cable or Splitter Protection Switch
Purpose
This task clears a Manual or Force protection switch on a Y-cable or splitter protection group.
Tools/Equipment
None
Prerequisite Procedures
One of the following tasks:
• G178 Apply a Manual Y-Cable or Splitter Protection Switch
Required/As Needed
As needed
Onsite/Remote
Both
Security Level
Maintenance or higher
Step 1 In node view (single-shelf mode) or shelf view (multishelf mode), click the Maintenance > Protection tabs.
Step 2 In the Protection Groups area, click the protection group that contains the card you want to clear.
Step 3 In the Selected Group area, click the card that you want to clear.
Step 4 In the Switch Commands drop-down list, click Clear.
Step 5 Click Yes in the confirmation dialog box.
The Manual or Force protection switch is cleared.
Step 6 Return to your originating procedure (NTP).
DLP-G181 Apply a Lock-On
Note You can apply the Lock On command only to the working/active card or port. If the working card or port is standby (traffic is switched), the Lock On button is not available.
Step 1 In node view (single-shelf mode) or shelf view (multishelf mode), click the Maintenance > Protection tabs.
Step 2 In the Protection Groups area, click the protection group that contains the card (Y-cable) or port (splitter) that you want to lock on.
Step 3 In the Selected Group area, click the working/active card.
Step 4 In the Inhibit Switching drop-down list, click Lock On.
Step 5 Click Yes in the confirmation dialog box.
The lock-on has been applied. Traffic cannot switch to the protect card. To clear the lock-on, see the "DLP-G183 Clear a Lock-On or Lockout" task.
Note Provisioning a lock-on raises a LOCKON-REQ or an FE-LOCKON condition in CTC. Clearing the lock-on switch request clears these conditions.
Step 6 Return to your originating procedure (NTP).
DLP-G182 Apply a Lockout
Note You can apply the lockout to the protect/standby card or port. If the protect card or port is active (traffic is switched), the lockout task cannot be performed.
Step 1 In node view (single-shelf mode) or shelf view (multishelf mode), click the Maintenance > Protection tabs.
Step 2 In the Protection Groups area, click the protection group that contains the card (Y-cable) or port (splitter) that you want to lock out.
Step 3 In the Selected Group area, click the protect/standby card.
Step 4 In the Inhibit Switching drop-down list, click Lock Out.
Step 5 Click Yes in the confirmation dialog box.
The lockout has been applied. Traffic cannot switch to the protect card. To clear the lockout, see the "DLP-G183 Clear a Lock-On or Lockout" task.
Note Provisioning a lockout raises a LOCKOUT-REQ or an FE-LOCKOUT condition in CTC. Clearing the lockout switch request clears these conditions.
Step 6 Return to your originating procedure (NTP).
DLP-G183 Clear a Lock-On or Lockout
Step 1 In node view (single-shelf mode) or shelf view (multishelf mode), click the Maintenance > Protection tabs.
Step 2 In the Protection Groups area, click the protection group that contains the card you want to clear.
Step 3 In the Selected Group area, click the card you want to clear.
Step 4 In the Inhibit Switching drop-down list, click Unlock.
Step 5 Click Yes in the confirmation dialog box.
The lock-on or lockout is cleared.
Step 6 Return to your originating procedure (NTP).
NTP-G85 Modify or Delete OSC Terminations, GCC Terminations, and Provisionable Patchcords
Purpose
This procedure modifies GCC terminations, and deletes provisionable patchcords, OSC terminations, and GCC terminations.
Tools/Equipment
None
Prerequisite Procedures
One or more of the following tasks:
• DLP-G76 Provision GCC Terminations, page 7-20
• NTP-G38 Provision OSC Terminations, page 3-84
Required/As Needed
As needed
Onsite/Remote
Onsite or remote
Security Level
Provisioning or higher
Caution Deleting an OSC termination can cause you to lose visibility of nodes that do not have other OSCs or network connections to the CTC computer.
Step 1 Complete the "DLP-G46 Log into CTC" task. If you are already logged in, continue with Step 2.
Step 2 In node view (single-shelf mode) or multishelf view (multishelf mode), complete the following tasks as needed:
•To modify a GCC termination, complete the "DLP-G184 Change a GCC Termination" task.
•To delete a GCC termination, complete the "DLP-G185 Delete a GCC Termination" task.
•To delete an OSC termination, complete the "DLP-G186 Delete an OSC Termination" task.
•To delete a provisionable patchcord, complete the "DLP-G187 Delete a Provisionable Patchcord" task.
Stop. You have completed this procedure.
DLP-G184 Change a GCC Termination
Step 1 Click the Provisioning > Comm Channels > GCC tabs.
Step 2 Click the GCC that you want to change.
Step 3 Click Edit.
Step 4 In the GCC Termination Editor dialog box, complete the following as necessary:
•GCC Rate—(Display only) Indicates the GCC rate.
•Disable OSPF on SDCC Link—If checked, OSPF is disabled on the link. OSPF should be disabled only when the slot and port connect to third-party equipment that does not support OSPF.
•Far End is Foreign—Check this box to specify that the GCC termination is a non-ONS node.
•Far end IP—If you checked the Far End is Foreign check box, type the IP address of the far-end node or leave the 0.0.0.0 default. An IP address of 0.0.0.0 means that any address can be used by the far end.
Step 5 Click OK.
Step 6 Return to your origination procedure (NTP).
DLP-G185 Delete a GCC Termination
Note Deleting the GCC termination on a port also deletes any provisionable patchcord links that might exist on the port.
Step 1 Click the Provisioning > Comm Channel > GCC tabs.
Step 2 Click the GCC that you want to delete.
Step 3 Click Delete.
Step 4 In the Delete GCC Terminations dialog box, check the Set port OOS check box if you want to place ports out of service.
Step 5 Click Yes. GCC-EOC alarms appear until all network GCC terminations are deleted and the ports are out of service.
Step 6 Return to your originating procedure (NTP).
DLP-G186 Delete an OSC Termination
Caution Deleting a OSC termination might cause node isolation and loss of visibility to nodes that do not have other OSCs or network connections to the CTC computer.
Step 1 Click the Provisioning > Comm Channel > OSC tabs.
Step 2 If a Ring ID is created, complete the following steps. Otherwise, continue with Step 3.
a. Select the DWDM Ring ID that you want to delete and click Delete.
b. In the Delete DWDM Ring ID confirmation box, click Yes. Confirm that the changes appear.
Step 3 Click the OSC termination that you want to delete and click Delete.
Step 4 In the Delete OSC Termination confirmation box, click Yes. Confirm that the changes appear.
Until all network OSC terminations are deleted, loss of signal (LOS) or power failure alarms might appear on the OPT-BST amplifier, OSCM card, and OSC-CSM card.
Step 5 Return to your originating procedure (NTP).
DLP-G187 Delete a Provisionable Patchcord
Purpose
This task deletes a provisionable patchcord.
Tools/Equipment
None
Prerequisite Procedures
Required/As Needed
As needed
Onsite/Remote
Onsite or remote
Security Level
Provisioning and higher
Step 1 In node view (single-shelf mode) or multishelf view (multishelf mode), click the Provisioning > Comm Channels > PPC tabs. If you are in network view, click Provisioning > Provisionable Patchcords tabs.
Step 2 Click the provisionable patchcord that you want to delete.
Step 3 Click Delete.
Step 4 In the confirmation dialog box, click Yes.
Step 5 Return to your originating procedure (NTP).
NTP-G86 Convert a Pass-Through Connection to Add/Drop Connections
Step 1 Complete the "DLP-G46 Log into CTC" task at an ONS 15454 on the network.
Step 2 In node view (single-shelf mode) or multishelf view (multishelf mode), click the Circuits tab. Delete the unidirectional or bidirectional pass-through optical channel network connection (OCHNC) that applies to the pass-through connection to be removed.
Step 3 Remove the physical pass-through cabling. Click the Provisioning > WDM-ANS > Internal Patchcords tabs to identify the card ports to be removed. The pass-through connection that you are removing can be connected in both OADM and hub nodes.
•For a hub node—Connect the 32DMX-O, 32DMX, or 32DMX-L output port to the 32MUX-O input port.
•For an OADM node—Connect the AD-xC-xx.x drop (TX) port to the AD-xC-xx.x add (RX) port.
Step 4 Physically connect the proper client interface to the correct add and drop ports.
Step 5 Delete the filter connections related to the pass-through connection that is being converted to an add/drop connection:
a. In node view (single-shelf mode) or multishelf view (multishelf mode), click the Provisioning > WDM-ANS > Port Status tabs.
b. Highlight the pass-through connections between ITU-T channel add and drop port filters.
c. Click Delete.
Step 6 Create two new unidirectional OCHNCs (one heading east, the other heading west) to support the new add/drop channels. See the "DLP-G105 Provision Optical Channel Network Connections" task on page 7-10.
Step 7 As necessary, complete the "DLP-G99 Create a Provisionable Patchcord" task on page 7-18.
Step 8 As necessary, add an optical attenuator between the channel TX port of the AD-xC-xx.x, 4MD-xx.x, 32DMX-O, 32DMX, or 32-DMX-L card and the DWDM RX port on the TXP, MXP, or OC-N/STM-N ITU-T line card.
Note If the channel is coming from a 32DMX-O, the optical power can be adjusted in CTC by modifying the value of the internal per-channel variable optical attenuator (VOA).
Step 9 (Optional) The following verification steps might be needed for an intermediate node when a pass-through connection is converted:
a. Verify that the received channels are at the specified power level. See the "G76 Verify Optical Span Loss Using CTC" procedure for instructions.
b. Verify that the added channels are equalized with the express channels within +/-1 dB.
c. If the channels are not equalized with the express channels within +/-1 dB, check the attenuation of the VOAs.
d. Check all the fiber adapters to minimize their insertion losses. See the "NTP-G115 Clean Fiber Connectors" procedure on page 13-26 for instructions.
Stop. You have completed this procedure.
NTP-G87 Change Node Timing Parameters
Purpose
This procedure changes the timing parameters for the ONS 15454. To switch the timing reference, see the "NTP-G112 Change the Node Timing Reference" procedure on page 13-18.
Tools/Equipment
None
Prerequisite Procedures
Required/As Needed
As needed
Onsite/Remote
Onsite or remote
Security Level
Provisioning or higher
Caution The following procedure might be service affecting and should be performed during a scheduled maintenance window.
Step 1 Complete the "DLP-G46 Log into CTC" task. If you are already logged in, continue with Step 2.
Step 2 Complete the "NTP-G103 Back Up the Database" procedure on page 13-2.
Step 3 Click the Provisioning > Timing > General tabs.
Step 4 In the General Timing section, change any of the following information:
•Timing Mode
Note Because mixed timing can cause timing loops, Cisco does not recommend using the Mixed Timing option. Use this mode with care.
•SSM Message Set
•Quality of RES
•Revertive
•Revertive Time
See the "NTP-G53 Set Up Timing" task for field descriptions.
Step 5 In the Reference Lists area, you can change the following information:
Note Reference lists define up to three timing references for the node and up to six BITS Out references. BITS Out references define the timing references used by equipment that can be attached to the node's BITS Out pins on the backplane. If you attach equipment to BITS Out pins, you normally attach it to a node with Line mode because equipment near the external timing reference can be directly wired to the reference.
•NE Reference
•BITS 1 Out
•BITS 2 Out
Step 6 Click the Provisioning > Timing > BITS Facilities tabs.
Step 7 In the BITS In section, you can change the following information:
Note The BITS Facilities section sets the parameters for your BITS1 and BITS2 timing references. Many of these settings are determined by the timing source manufacturer. If equipment is timed through BITS Out, you can set timing parameters to meet the requirements of the equipment.
•BITS In State
•Coding
•State
•Framing
•Sync Messaging
•Admin SSM
Step 8 In the BITS Out section, you can change the following information:
•Coding
•Framing
•AIS Threshold
•LBO
Step 9 Click Apply. Confirm that the changes appear.
Caution Internal timing is Stratum 3 and is not intended for permanent use. All ONS 15454s should be timed to a Stratum 2 or better primary reference source.
Step 10 Complete the "NTP-G103 Back Up the Database" procedure on page 13-2.
Stop. You have completed this procedure.
NTP-G88 Modify Users and Change Security
Step 1 Complete the "DLP-G46 Log into CTC" task. If you are already logged in, continue with Step 2.
Step 2 Complete the "NTP-G103 Back Up the Database" procedure on page 13-2.
Step 3 Perform any of the following tasks as needed:
• G188 Change Security Policy for a Single Node
• G189 Change Security Policy for Multiple Nodes
• G317 Change Node Access and PM Clearing Privilege
• G328 Grant Superuser Privileges to a Provisioning User
• G191 Change User Password and Security Level on a Single Node
• G192 Change User Password and Security Level for Multiple Nodes
• G193 Delete a User From a Single Node
• G194 Delete a User From Multiple Nodes
• G195 Log Out a User on a Single Node
• G196 Log Out a User on Multiple Nodes
• G281 Configure the Node for RADIUS Authentication
• G282 View and Terminate Active Logins
Step 4 Complete the "NTP-G103 Back Up the Database" procedure on page 13-2.
Stop. You have completed this procedure.
DLP-G188 Change Security Policy for a Single Node
Step 1 In node view (single-shelf mode) or multishelf view (multishelf mode), click the Provisioning > Security > Policy tabs.
Step 2 If you want to modify the idle user timeout period, click the hour (H) and minute (M) arrows in the Idle User Timeout area for the security level that you want to provision: RETRIEVE, MAINTENANCE, PROVISIONING, or SUPERUSER. The idle period time range is 0 and 16 hours, and 0 and 59 minutes. The user is logged out after the idle user timeout period is reached.
Step 3 In the User Lockout area, you can modify the following:
•Failed Logins Before Lockout—The number of failed login attempts a user can make before the user is locked out from the node. You can choose a value between 0 and 10.
•Manual Unlock by Superuser—Allows a user with Superuser privileges to manually unlock a user who has been locked out from a node.
•Lockout Duration—Sets the amount of time the user will be locked out after a failed login. You can choose a value between 0 and 10 minutes, and 0 and 55 seconds (in five-second intervals).
Note Manual Unlock by Superuser and Lockout Duration are mutually exclusive.
Step 4 In the Password Change area, you can modify the following:
•Prevent Reusing Last [ ] Passwords—Choose a value between 1 and 10 to set the number of different passwords that the user must create before they can reuse a password.
•New Password must Differ from the Old Password—Choose the number of characters that must differ between the old and new password. The default number is 1. The range is 1 to 5.
•Cannot Change New Password for [ ] days—If checked, prevents users from changing their password for the specified period. The range is 20 to 95 days.
•Require Password Change on First Login to New Account—If checked, requires users to change their password the first time they log into their account.
Step 5 To require users to change their password at periodic intervals, check the Enforce Password Aging check box in the Password Aging area. If checked, provision the following parameters:
•Aging Period—Sets the amount of time that must pass before the user must change his or her password for each security level: RETRIEVE, MAINTENANCE, PROVISIONING, and SUPERUSER. The range is 20 to 95 days.
•Warning Period—Sets the number days the user will be warned to change his or her password for each security level. The range is 2 to 20 days.
Step 6 In the Other area, you can provision the following:
•Single Session Per User—If checked, limits users to one login session at one time.
•Disable Inactive User—If checked, disables users who do not log into the node for the period of time specified in the Inactive Duration box. The Inactive Duration range is 1 to 99 days.
Step 7 Click Apply. Confirm that the changes appear.
Step 8 Return to your originating procedure (NTP).
DLP-G189 Change Security Policy for Multiple Nodes
Step 1 From the View menu, choose Go to Network View.
Step 2 Click the Provisioning > Security > Policy tabs. A read-only table of nodes and their policies appears.
Step 3 Click a node on the table that you want to modify, then click Change.
Step 4 If you want to modify the idle user timeout period, click the hour (H) and minute (M) arrows in the Idle User Timeout area for the security level that you want to provision: RETRIEVE, MAINTENANCE, PROVISIONING, or SUPERUSER. The idle period time range is 0 and 16 hours, and 0 and 59 minutes. The user is logged out after the idle user timeout period is reached.
Step 5 In the User Lockout area, you can modify the following:
•Failed Logins Before Lockout—The number of failed login attempts a user can make before the user is locked out from the node. You can choose a value between 0 and 10.
•Manual Unlock by Superuser—Allows a user with Superuser privileges to manually unlock a user who has been locked out from a node.
•Lockout Duration—Sets the amount of time the user will be locked out after a failed login. You can choose a value between 0 and 10 minutes, and 0 and 55 seconds (in five-second intervals).
Note Manual Unlock by Superuser and Lockout Duration are mutually exclusive.
Step 6 In the Password Change area, you can modify the following:
•Prevent Reusing Last [ ] Passwords—Choose a value between 1 and 10 to set the number of different passwords that the user must create before they can reuse a password.
•New Password must Differ from the Old Password—Choose the number of characters that must differ between the old and new password. The default number is 1. The range is 1 to 5.
•Cannot Change New Password for [ ] days—If checked, prevents users from changing their password for the specified period. The range is 20 to 95 days.
•Require Password Change on First Login to New Account—If checked, requires users to change their password the first time they log into their account.
Step 7 To require users to change their password at periodic intervals, check the Enforce Password Aging check box in the Password Aging area. If checked, provision the following parameters:
•Aging Period—Sets the amount of time that must pass before the user must change his or her password for each security level: RETRIEVE, MAINTENANCE, PROVISIONING, and SUPERUSER. The range is 20 to 95 days.
•Warning Period—Sets the number days the user will be warned to change his or her password for each security level. The range is 2 to 20 days.
Step 8 In the Other area, you can provision the following:
•Single Session Per User—If checked, limits users to one login session at one time.
•Disable Inactive User—If checked, disables users who do not log into the node for the period of time specified in the Inactive Duration box. The Inactive Duration range is 1 to 99 days.
Step 9 In the Select Applicable Nodes area, uncheck any nodes where you do not want to apply the changes.
Step 10 Click OK.
Step 11 In the Security Policy Change Results dialog box, confirm that the changes are correct, then click OK.
Step 12 Return to your originating procedure (NTP).
DLP-G317 Change Node Access and PM Clearing Privilege
Step 1 In node view (single-shelf mode) or multishelf view (multishelf mode), click the Provisioning > Security > Access tabs.
Step 2 In the Access area, provision the following:
•LAN access—Choose one of the following options to set the access paths to the node:
–No LAN Access—Allows access to the node only through DCC connections. Access through the TCC2/TCC2P RJ-45 port and backplane is not permitted.
–Front only—Allows access through the TCC2/TCC2P RJ-45 port. Access through the DCC and the backplane is not permitted.
–Backplane only—Allows access through DCC connections and the backplane. Access through the TCC2/TCC2P RJ-45 port is not allowed.
–Front and Backplane—Allows access through DCC, TCC2/TCC2P RJ-45 port, and backplane connections.
•Restore Timeout—Sets a time delay for enabling of front and backplane access when DCC connections are lost and "DCC only" is chosen in LAN Access. Front and backplane access is enabled after the restore timeout period has passed. Front and backplane access is disabled as soon as DCC connections are restored.
Step 3 In the Shell Access area, set the shell program used to access the node:
•Access State—Allows you to set the shell program access mode to Disable (disables shell access), Non-Secure, or Secure. Secure mode allows access to the node using the Secure Shell (SSH) program. SSH is a terminal-remote host Internet protocol that uses encrypted links.
•Telnet Port—Allows access to the node using the Telnet port. Telnet is the terminal-remote host Internet protocol developed for the Advanced Agency Research Project Network (ARPANET). Port 23 is the default.
•Enable Shell Password—If checked, enables the SSH password. To enable the shell password, check the box and click Apply. To disable the password, uncheck the check box, click Apply, type the current password in the Disable Shell Password dialog box, then click OK.
Step 4 In the TL1 Access area, select the desired level of TL1 access. Disabled completely disables all TL1 access; Non-Secure and Secure allow access using SSH.
Step 5 In the PM Clearing Privilege field, choose the minimum security level that can clear node PM data: PROVISIONING or SUPERUSER.
Step 6 Select the Enable Craft Port check box to turn on the shelf controller serial ports.
Step 7 Select the EMS access state from the list. Available states are Non-Secure and Secure (allows access using SSH).
Step 8 In the TCC CORBA (IIOP/SSLIOP) Listener Port area, choose a listener port option:
•Default - TCC Fixed—Uses Port 57790 to connect to ONS 15454s on the same side of the firewall or if no firewall is used (default). This option can be used for access through a firewall if Port 57790 is open.
•Standard Constant—Uses Port 683 (IIOP) or Port 684 (SSLIOP), the CORBA default port number.
•Other Constant—If the default port is not used, type the IIOP or SSLIOP (Secure Socket Layer Inter-ORB Protocol) port specified by your firewall administrator.
Step 9 In the SNMP Access area, set the Simple Network Management Protocol (SNMP) access state to Non-Secure or Disabled (disables SNMP access).
Step 10 Click Apply.
Step 11 Return to your originating procedure (NTP).
DLP-G328 Grant Superuser Privileges to a Provisioning User
Step 1 In node view (single-shelf mode) or multishelf view (multishelf mode), click the Provisioning > Defaults tabs.
Step 2 In the Defaults Selector area, choose NODE.
Step 3 In the Default Name area, choose one of the following parameters:
•NODE.security.grantPermission.RetrieveAuditLog
•NODE.security.grantPermission.RestoreDB
•NODE.security.grantPermission.PMClearingPrivilege
•NODE.security.grantPermission.ActivateRevertSoftware
Step 4 Click the Default Value column and choose Provisioning from the drop-down list for each property in Step 3 that you want to change.
Note If you click Reset before you click Apply, all values will return to their original settings.
Step 5 Click Apply.
A pencil icon will appear next to the default name that will be changed as a result of editing the defaults file.
Step 6 Return to your originating procedure (NTP).
DLP-G191 Change User Password and Security Level on a Single Node
Purpose
This task changes settings for an existing user at one node.
Tools/Equipment
None
Prerequisite Procedures
Required/As Needed
As needed
Onsite/Remote
Onsite or remote
Security Level
Superuser
Note Each ONS 15454 must have one user with a Superuser security level. The default CISCO15 user name and security level cannot be changed unless you create another user with Superuser security.
Step 1 In node view (single-shelf mode) or multishelf view (multishelf mode), click the Provisioning > Security > Users tabs.
Step 2 Click the user whose settings you want to modify, then click Edit.
Step 3 In the Change User dialog box, you can:
•Change a user password.
•Modify the user security level.
•Lock out the user.
•Disable the user.
•Force the user to change password on next login.
See the "DLP-G54 Create a New User on a Single Node" procedure on page 3-8 for field descriptions.
Step 4 Click OK.
Step 5 Click OK in the confirmation dialog box.
Note User settings that you changed during this task will not appear until that user logs off and logs back in.
Step 6 Return to your originating procedure (NTP).
DLP-G192 Change User Password and Security Level for Multiple Nodes
Note You must add the same user name and password to each node that the user will access.
Step 1 From the View menu, choose Go to Network View. Verify that you can access all the nodes where you want to change the users.
Step 2 Click the Provisioning > Security > Users tabs. Highlight the user's name whose settings you want to change.
Step 3 Click Change. The Change User dialog box appears.
Step 4 In the Change User dialog box, you can:
•Change a user's password.
•Modify the user's security level.
•Lock out the user.
•Disable the user.
•Force the user to change password on next login.
See the "DLP-G55 Create a New User on Multiple Nodes" task on page 3-9 for field descriptions.
Step 5 In the Select Applicable Nodes area, uncheck any nodes where you do not want to change the user's settings (all network nodes are selected by default).
Note The Select Applicable Nodes area does not appear for users who are provisioned for only one node.
Step 6 Click OK. A Change Results confirmation dialog box appears.
Step 7 Click OK to acknowledge the changes.
Step 8 Return to your originating procedure (NTP).
DLP-G193 Delete a User From a Single Node
Purpose
This task deletes an existing user from a single node.
Tools/Equipment
None
Prerequisite Procedures
Required/As Needed
As needed
Onsite/Remote
Onsite or remote
Security Level
Superuser
Note You cannot delete a user who is currently logged in. To log out a user, you can complete the "DLP-G195 Log Out a User on a Single Node" task, or you can choose the "Logout before delete" option in the Delete User dialog box.
Note CTC will allow you to delete other Superusers if one Superuser remains. For example, you can delete the CISCO15 user if you have created another Superuser. Use this option with caution.
Step 1 In node view (single-shelf mode) or multishelf view (multishelf mode), click the Provisioning > Security > Users tabs.
Step 2 Choose the user that you want to delete.
Step 3 Click Delete.
Step 4 In the Delete User dialog box, verify that the user name displayed is the one that you want to delete. Click Logout before delete if the user is currently logged in. (You cannot delete users if they are logged in.)
Step 5 Click OK.
Step 6 In the User Deletion Results box, click OK.
Step 7 Return to your originating procedure (NTP).
DLP-G194 Delete a User From Multiple Nodes
Purpose
This task deletes an existing user from multiple nodes.
Tools/Equipment
None
Prerequisite Procedures
Required/As Needed
As needed
Onsite/Remote
Onsite or remote
Security Level
Superuser
Note You cannot delete a user who is currently logged in. To log out a user, you can complete the "DLP-G196 Log Out a User on Multiple Nodes" task, or you can choose the "Logout before delete" option in the Delete User dialog box.
Note CTC will allow you to delete other Superusers if one Superuser remains. For example, you can delete the CISCO15 user if you have created another Superuser. Use this option with caution.
Step 1 From the View menu, choose Go to Network View.
Step 2 Click the Provisioning > Security tabs. Highlight the name of the user you want to delete.
Step 3 Click Delete. The Delete User dialog box appears.
Step 4 In the Select Applicable Nodes area, uncheck any nodes where you do not want to delete this user.
Note The Select Applicable Nodes area does not appear for users who are provisioned for only one node.
Step 5 Click OK. A User Deletion Results confirmation dialog box appears.
Step 6 Click OK to acknowledge the changes.
Step 7 Return to your originating procedure (NTP).
DLP-G195 Log Out a User on a Single Node
Purpose
This task logs out a user from a single node.
Tools/Equipment
None
Prerequisite Procedures
Required/As Needed
As needed
Onsite/Remote
Onsite or remote
Security Level
Superuser
Step 1 In node view (single-shelf mode) or multishelf view (multishelf mode), click the Provisioning > Security > Active Logins tabs.
Step 2 Choose the user that you want to log out and click Logout.
Step 3 In the Logout User dialog box, check Lockout before Logout if you want to lock the user out. This prevents the user from logging in after logout based on user lockout parameters provisioned in the Policy tab. A manual unlock by a Superuser is required, or else the user is locked out for the amount of time specified in the Lockout Duration field. See the "DLP-G188 Change Security Policy for a Single Node" task for more information.
Step 4 Click OK.
Step 5 Click OK to confirm the logout.
Step 6 Return to your originating procedure (NTP).
DLP-G196 Log Out a User on Multiple Nodes
Purpose
This task logs out a user from multiple nodes.
Tools/Equipment
None
Prerequisite Procedures
Required/As Needed
As needed
Onsite/Remote
Onsite or remote
Security Level
Superuser
Step 1 From the View menu, chose Go to Network View.
Step 2 Click the Provisioning > Security > Active Logins tabs.
Step 3 Choose the user that you want to log out.
Step 4 Click Logout.
Step 5 In the Logout User dialog box, check the nodes where you want to log out the user.
Step 6 Check Lockout before Logout if you want to lock the user out prior to logout. This prevents the user from logging in after logout based on user lockout parameters provisioned in the Policy tab. A manual unlock by a Superuser is required, or else the user is locked out for the amount of time specified in the Lockout Duration field. See the "DLP-G189 Change Security Policy for Multiple Nodes" task for more information.
Step 7 In the Select Applicable Nodes area, uncheck any nodes where you do not want to change the user's settings (all network nodes are selected by default).
Step 8 Click OK.
Step 9 Click OK in the confirmation dialog box.
Step 10 Return to your originating procedure (NTP).
DLP-G281 Configure the Node for RADIUS Authentication
Caution Do not configure a node for RADIUS authentication until after you have added that node to the RADIUS server and added the RADIUS server to the list of authenticators. If you do not add the node to a RADIUS server prior to activating RADIUS authentication, no user will be able to access the node. Refer to the User Guide for Cisco Secure ACS for Windows Server for more information about adding a node to a RADIUS server.
Note The following Cisco vendor-specific attribute (VSA) needs to be specified when adding users to the RADIUS server:
shell:priv-lvl=N
where N is equal to:
•0 for Retrieve user
•1 for Maintenance user
•2 for Provisioning user
•3 for Superuser
Step 1 In node view (single-shelf mode) or multishelf view (multishelf mode), click the Provisioning > Security > RADIUS Server tabs ( Figure 10-5).
Figure 10-5 RADIUS Server Tab
Step 2 Click Create to add a RADIUS server to the list of authenticators. The Create RADIUS Server Entry dialog box appears ( Figure 10-6).
Figure 10-6 Create RADIUS Server Entry Window
Step 3 Enter the RADIUS server IP address in the IP Address field. If the node is an end network element (ENE), enter the IP address of the gateway network element (GNE) in this field.
The GNE passes authentication requests from the ENEs in its network to the RADIUS server, which grants authentication if the GNE is listed as a client on the server.
Caution Because the ENE nodes use the GNE to pass authentication requests to the RADIUS server, you must add the ENEs to the RADIUS server individually for authentication. If you do not add the ENE node to a RADIUS server prior to activating RADIUS authentication, no user will be able to access the node. Refer to the User Guide for Cisco Secure ACS for Windows Server for more information about adding a node to a RADIUS server.
Step 4 Enter the shared secret in the Shared Secret field. A shared secret is a text string that serves as a password between a RADIUS client and RADIUS server.
Step 5 Enter the RADIUS authentication port number in the Authentication Port field. The default port is 1812. If the node is an ENE, set the authentication port to a number within the range of 1860 to 1869.
Step 6 Enter the RADIUS accounting port in the Accounting Port field. The default port is 1813. If the node is an ENE, set the accounting port to a number within the range of 1870 to 1879.
Step 7 Click OK. The RADIUS server is added to the list of RADIUS authenticators.
Note You can add up to 10 RADIUS servers to a node's list of authenticators.
Step 8 Click Edit to make changes to an existing RADIUS server. You can change the IP address, the shared secret, the authentication port, and the accounting port.
Step 9 Click Delete to delete the selected RADIUS server.
Step 10 Select a server and click Move Up or Move Down to reorder that server in the list of RADIUS authenticators. The node requests authentication from the servers sequentially from top to bottom. If one server is unreachable, the node will request authentication from the next RADIUS server on the list.
Step 11 Click the Enable RADIUS Authentication check box to activate remote-server authentication for the node.
Step 12 Click the Enable RADIUS Accounting check box if you want to show RADIUS authentication information in the audit trail.
Step 13 Click the Enable the Node as the Final Authenticator check box if you want the node to be the final autheticator. This means that if every RADIUS authenticator is unavailable, the node will authenticate the login rather than locking the user out.
Step 14 Click Apply to save all changes or Reset to clear all changes.
Step 15 Return to your originating procedure (NTP).
DLP-G282 View and Terminate Active Logins
Step 1 In node view (single-shelf mode) or multishelf view (multishelf mode), click the Provisioning > Security > Active Logins tabs. The Active Logins tab displays the following information:
•User ID
•User IP address
•Current node the user is logged into
•Session Type (EMS, TL1, FTP, Telnet, or SSH)
•Login time
•Last activity time
Step 2 Click Logout to end the session of every logged-in user. This will log out all current users, excluding the initiating Superuser.
Step 3 Click Retrieve Last Activity Time to display the most recent activity date and time for users in the Last Activity Time field.
Step 4 Return to your originating procedure (NTP).
NTP-G131 Convert DWDM Nodes to Hybrid Nodes
Note You cannot perform this upgrade on software released prior to Software Release 4.6.
Note Downgrade procedures from OSC-CSM cards to OSCM cards are not supported. Contact the Cisco Technical Assistance Center (TAC) for more information. See the "Obtaining Technical Assistance" section on page lvii.
Step 1 Complete the "DLP-G46 Log into CTC" task at the node where you will perform the upgrade. If you are already logged in, continue with Step 2.
Step 2 Complete the "NTP-G103 Back Up the Database" procedure on page 13-2.
Step 3 If you have timing set up on the OSCM card, delete the timing source:
a. In node view (single-shelf mode) or shelf view (multishelf mode), click the Provisioning > Timing tabs.
b. Scroll to the Reference Lists area.
c. In the NE Reference column, select Internal Clock from the drop-down list for all entries where the selected Clock Source is the OSCM that you are removing.
d. Click Apply.
Step 4 If you have overhead circuits on the node, complete the "DLP-G112 Delete Overhead Circuits" task on page 7-27.
Step 5 Delete the DWDM ring ID:
a. In node view (single-shelf mode) or multishelf view (multishelf mode), click the Provisioning > Comm Channels > OSC tabs.
b. Select the DWDM Ring ID that you want to delete and click Delete.
c. In the Delete DWDM Ring ID confirmation box, click Yes. Confirm that the changes appear.
Step 6 If you have OSC terminations, refer to the "DLP-G186 Delete an OSC Termination" task to delete the OSC termination.
Step 7 Delete the OSCM card wavelength division multiplexing-automatic node setup (WDM-ANS) connections:
a. In node view (single-shelf mode) or multishelf view (multishelf mode), click the Provisioning > WDM-ANS > Internal Patchcords tabs.
b. Select the connection to be deleted.
c. Click Delete.
d. In the Delete Optical Link dialog box, click Yes.
Step 8 Delete the card from CTC:
a. In node view (single-shelf mode) or shelf view (multishelf mode), right-click the OSCM card.
b. Select Delete Card from the shortcut menu.
The card name disappears and the slot turns gray.
Step 9 Remove the cables from the OSCM OSC ports.
Step 10 Physically replace the deleted OSCM card on the ONS 15454 with an OSC-CSM card:
Note The OSCM card and OSC-CSM card do not have the same slot requirements.
a. Open the OSCM card ejectors.
b. Slide the card out of Slot 8 or 10.
c. Open the ejectors on the OSC-CSM card.
d. Slide the OSC-CSM card into the slot along the guide rails in the slots directed by your site plan.
e. Close the ejectors.
Note On the OSC-CSM card, the fail LED above the ACT/STBY LED becomes red, blinks for several seconds, and turns off. The ACT/STBY LED turns green and remains on. In node view (single-shelf mode) or shelf view (multishelf mode), the OSC-CSM appears green.
Step 11 If an OSCM card was removed from Slot 8 and an OSC-CSM card was installed in Slots 12 to 17, modify the OSC-CSM line direction from east-to-west to west-to-east.
Note The Cisco MetroPlanner configuration file labels the OSC-CSM card as west even if it is installed in the east side of the node.
a. To modify the OSC-CSM card line direction, double-click the OSC-CSM card in node view (single-shelf mode) or shelf view (multishelf mode). The card view appears.
a. Click the Provisioning > Optical Line > Parameter tabs.
b. In the Port 2 line, click the Line Direction drop-down list and choose West to East.
c. Click Apply.
Step 12 If an OSCM card was removed from Slot 10 and an OSC-CSM card was installed in Slots 1 to 6, modify the OSC-CSM line direction from west-to-east to east-to-west.
Note The Cisco MetroPlanner configuration file will label the OSC-CSM card as east even if it is installed in the west side of the node.
a. To modify the OSC-CSM card line direction, double-click the OSC-CSM card in node view (single-shelf mode) or shelf view (multishelf mode). The card view appears.
b. Click the Provisioning > Optical Line > Parameter tabs.
c. In the Port 2 line, click the Line Direction drop-down list and choose East to West.
d. Click Apply.
Step 13 Verify the default internal patchcords:
a. Click the CTC up arrow to return to node view or multishelf view.
a. Click the Provisioning > WDM-ANS > Internal Patchcords tabs.
b. Click Default Patchcords.
Step 14 Connect the cables from the OSC-CSM LINE ports to the OPT-BST amplifier OSC ports. Follow the recommended connections that were automatically calculated in the Internal Patchcords tab as described in Step 13.
Step 15 Launch ANS port regulation:
a. Click the Provisioning > WDM-ANS > Port Status tabs.
b. Click the Launch ANS button.
c. In the Link Status column, the ports change to Regulated.
Step 16 Create OSC terminations starting from the OSC-CSM card. See the "NTP-G38 Provision OSC Terminations" task on page 3-84.
Step 17 (Optional) If you want to set up timing on the OSC-CSM card, create the timing source:
a. In node view (single-shelf mode) or shelf view (multishelf mode), click the Provisioning > Timing tabs.
b. Scroll down to the Reference Lists area.
c. In the NE Reference column, select Internal Clock from the drop-down list for all entries where the selected Clock Source is the OSC-CSM that you are adding.
d. Click Apply.
Step 18 (Optional) Complete the "NTP-G60 Create and Delete Overhead Circuits" procedure on page 7-19.
Step 19 Repeat Steps 3 through 18 for each OSCM card you are replacing in the node.
Step 20 If you are installing cross-connect cards, refer to the Cisco ONS 15454 Procedure Guide or the Cisco ONS 15454 SDH Procedure Guide for instructions.
Stop. You have completed this procedure.
NTP-G89 Change SNMP Settings
Step 1 Complete the "DLP-G46 Log into CTC" task. If you are already logged in, continue with Step 2.
Step 2 Complete the "NTP-G103 Back Up the Database" procedure on page 13-2.
Step 3 Perform any of the following tasks as needed:
• G197 Modify SNMP Trap Destinations
• G198 Delete SNMP Trap Destinations
Step 4 Complete the "NTP-G103 Back Up the Database" procedure on page 13-2.
Stop. You have completed this procedure.
DLP-G197 Modify SNMP Trap Destinations
Step 1 In node view (single-shelf mode) or multishelf view (multishelf mode), click the Provisioning > SNMP tabs.
Step 2 Select a trap from the Trap Destinations area.
For a description of SNMP traps, refer to the Cisco ONS 15454 DWDM Reference Manual.
Step 3 Highlight the Destination row field entry in the Community column and change the entry to another valid community name.
The community name is a form of authentication and access control. The community name assigned to the ONS 15454 is case-sensitive and must match the community name of the network management system (NMS).
Step 4 If needed, modify the UDP port in the UDP Port field. The default UDP port for SNMP is 162.
Step 5 Set the Trap Version field for either SNMPv1 or SNMPv2.
Refer to your NMS documentation to determine whether to use SNMPv1 or SNMPv2.
Step 6 If you want the SNMP agent to accept SNMP SET requests on certain MIBs, click the Allow SNMP Sets check box. If this box is not checked, SET requests are rejected.
Step 7 If you want to set up the SNMP proxy feature to allow network management, message reporting, and performance statistics retrieval across ONS firewalls, click the Enable SNMP Proxy check box located on the SNMP tab.
Step 8 Click Apply.
Step 9 SNMP settings are now modified. To view SNMP information for each node, highlight the node IP address in the Trap Destinations area of the Trap Destinations area. Confirm that the changes appear; if not, repeat the task.
Step 10 Return to your originating procedure (NTP).
DLP-G198 Delete SNMP Trap Destinations
Step 1 In node view (single-shelf mode) or multishelf view (multishelf mode), click the Provisioning > SNMP tabs.
Step 2 In the Trap Destinations area, click the trap that you want to delete.
Step 3 Click Delete. A confirmation dialog box appears.
Step 4 Click Yes. Confirm that the changes appear; if not, repeat the task.
Step 5 Return to your originating procedure (NTP).
Posted: Tue Feb 6 07:13:02 PST 2007
All contents are Copyright © 1992--2007 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.