Table 13 Ports
DLT-<MOD1PAYLOAD>:[<TID>]:<AID>:<CTAG>[::::];
Deletes the specified port (support limited to ports with Pluggable Port Modules [PPM]) (not supported on the ONS 15327).
|
ED-<GIGE_TYPE>:[<TID>]:<AID>:<CTAG>:::[ADMINSTATE=<ADMINSTATE>], [LINKSTATE=<LINKSTATE>],[MTU=<MTU>],[FLOWCTRL=<FLOWCTRL>], [AUTONEG=<AUTONEG>],[HIWMRK=<HIWMRK>],[LOWMRK=<LOWMRK>], [OPTICS=<OPTICS>],[DUPLEX=<DUPLEX>],[SPEED=<SPEED>],[NAME=<NAME>], [CMDMDE=<CMDMDE>],[MACADDR=<MACADDR>],[FREQ=<FREQ>],[LOSSB=<LOSSB>], [SOAK=<SOAK>]:[<PST>[,<SST>]];
Edits the Gigabit Ethernet Facility attributes (not supported on the ONS 15327).
|
ED-<MOD1FCPAYLOAD>:[<TID>]:<AID>:<CTAG>:::[LINKRCVRY=<LINKRCVRY>], [DISTEXTN=<DISTEXTN>],[AUTODETECTION=<AUTODETECTION>], [LINKCREDITS=<LINKCREDITS>],[MFS=<MFS>],[NAME=<NAME>], [CMDMDE=<CMDMDE>],[SOAK=<SOAK>],[FREQ=<FREQ>], [LOSSB=<LOSSB>]:[<PST>[,<SST>]];
Edits the attributes related with the fibre channel facility (ONS 15454 only).
|
ED-<MOD1FICONPAYLOAD>:[<TID>]:<AID>:<CTAG>:::[LINKRCVRY=<LINKRCVRY>], [DISTEXTN=<DISTEXTN>],[AUTODETECTION=<AUTODETECTION>], [LINKCREDITS=<LINKCREDITS>],[MFS=<MFS>],[NAME=<NAME>], [CMDMDE=<CMDMDE>],[SOAK=<SOAK>],[FREQ=<FREQ>], [LOSSB=<LOSSB>]:[<PST>[,<SST>]];
Edits the attributes related with the fiber connection payload facility (ONS 15454 only).
|
ED-<OCN_TYPE>:[<TID>]:<AID>:<CTAG>:::[DCC=<DCC>],[AREA=<AREA>], [SYNCMSG=<SYNCMSG>],[SENDDUS=<SENDDUS>],[PJMON=<PJMON>], [SFBER=<SFBER>],[SDBER=<SDBER>],[MODE=<MODE>],[MUX=<MUX>],[SOAK=<SOAK>], [OSPF=<OSPF>],[LDCC=<LDCC>],[NAME=<NAME>],[CMDMDE=<CMDMDE>], [EXPTRC=<EXPTRC>],[TRC=<TRC>],[TRCMODE=<TRCMODE>], [TRCFORMAT=<TRCFORMAT>],[ADMSSM=<ADMSSM>],[SENDDUSFF=<SENDDUSFF>], [AISONLPBK=<AISONLPBK>],[FREQ=<FREQ>],[LOSSB=<LOSSB>], [FOREIGNFEND=<FOREIGNFEND>],[FOREIGNIP=<FOREIGNIP>]:[<PST>[,<SST>]];
Edits the attributes and state of an OC-N facility.
|
ED-ALS:[<TID>]:<SRC>:<CTAG>:::[ALSMODE=<ALSMODE>],[ALSRCINT=<ALSRCINT>], [ALSRCPW=<ALSRCPW>];
Modifies the Automatic Laser Shutdown (ALS) attributes for all facilities that support the ALS feature (ONS 15454 and ONS 15310-CL only).
|
ED-DS1:[<TID>]:<AID>:<CTAG>:::[TACC=<TACC>],[TAPTYPE=<TAPTYPE>], [AISONLPBK=<AISONLPBK>],[MODE=<MODE>],[FMT=<FMT>];
Edits the test access attributes for DS1 access on a DS3XM card (ONS 15454 only).
|
ED-EC1:[<TID>]:<AID>:<CTAG>:::[PJMON=<PJMON>],[LBO=<LBO>],[SOAK=<SOAK>], [SFBER=<SFBER>],[SDBER=<SDBER>],[NAME=<NAME>],[EXPTRC=<EXPTRC>], [TRC=<TRC>],[TRCMODE=<TRCMODE>],[<TRCFORMAT>],[AISONLPBK=<AISONLPBK>], [CMDMDE=<CMDMDE>]:[<PST>[,<SST>]];
Edits the attributes of an EC1 facility (ONS 15454, ONS 15310-CL, ONS 15310-MA).
|
ED-FAC:[<TID>]:<SRC>:<CTAG>:::[PAYLOAD=<PAYLOAD>], [CMDMDE=<CMDMDE>]:[<PST>[,<SST>]];
Provisions the payload (or signal) type of facility.
|
ED-FSTE:[<TID>]:<AID>:<CTAG>:::[FLOW=<FLOW>],[EXPDUPLEX=<EXPDUPLEX>], [EXPSPEED=<EXPSPEED>],[VLANCOS=<VLANCOS>],[IPTOS=<IPTOS>],[NAME=<NAME>], [CMDMDE=<CMDMDE>],[SOAK=<SOAK>]:[<PST>[,<SST>]];
Edits the front end port information of fast (10/100 Mbps) ethernet cards (ONS 15454, ONS 15310-CL, ONS 15310-MA).
|
ED-G1000:[<TID>]:<AID>:<CTAG>:::[MFS=<MFS>],[FLOW=<FLOW>], [LOWMRK=<LOWMRK>],[HIWMRK=<HIWMRK>],[AUTONEG=<AUTONEG>], [NAME=<NAME>],[CMDMDE=<CMDMDE>],[SOAK=<SOAK>]:[<PST>[,<SST>]];
Edits the attributes related to a G1000 port (ONS 15454 and ONS 15327 only).
|
ED-GFP:[<TID>]:<AID>:<CTAG>:::[FCS=<FCS>],[AUTOTHGFPBUF=<AUTOTHGFPBUF>], [GFPBUF=<GFPBUF>],[FILTER=<FILTER>];
Edits the Generic Framing Procedure (GFP) port on the ONS 15310-CL/ONS 15310-MA ML-100T-8, ONS 15454 CE-100T-8, FC_MR-4, and CE-1000-4, and ONS 15600 ASAP-4 cards.
|
ED-POS:[<TID>]:<AID>:<CTAG>:::[ENCAP=<ENCAP>],[NAME=<NAME>], [CMDMDE=<CMDMDE>],[SOAK=<SOAK>]:[<PST>[,<SST>]];
Edits the back-end virtual port information on the ONS 15310-CL/ONS 15310-MA ML-100T-8, ONS 15454 CE-100T-8 and CE-1000-4, and ONS 15600 ASAP-4 cards.
|
ED-T1:[<TID>]:<AID>:<CTAG>:::[LINECDE=<LINECDE>],[FMT=<FMT>],[LBO=<LBO>], [TACC=<TACC>],[TAPTYPE=<TAPTYPE>],[SOAK=<SOAK>],[SFBER=<SFBER>], [SDBER=<SDBER>],[SYNCMSG=<SYNCMSG>],[SENDDUS=<SENDDUS>], [RETIME=<RETIME>],[NAME=<NAME>],[MODE=<MODE>],[SYNCMAP=<SYNCMAP>], [ADMSSM=<ADMSSM>],[VTMAP=<VTMAP>],[INHFELPBK=<INHFELPBK>], [AISONLPBK=<AISONLPBK>],[CMDMDE=<CMDMDE>],[AISVONAIS=<AISVONAIS>], [AISONLOF=<AISONLOF>]:[<PST>[,<SST>]];
Edits the attributes related a DS1/T1 port (not supported on the ONS 15600).
|
ED-T3:[<TID>]:<AID>:<CTAG>:::[FMT=<FMT>],[LINECDE=<LINECDE>],[LBO=<LBO>], [INHFELPBK=<INHFELPBK>],[TACC=<TACC>],[TAPTYPE=<TAPTYPE>],[SOAK=<SOAK>], [SFBER=<SFBER>],[SDBER=<SDBER>],[NAME=<NAME>],[AISONLPBK=<AISONLPBK>], [CMDMDE=<CMDMDE>]:[<PST>[,<SST>]];
Edits the attributes related to a DS3/T3 port (not supported on the ONS 15600).
|
ENT-<MOD1PAYLOAD>:[<TID>]:<AID>:<CTAG>[::::];
Provisions the specified port (support limited to ports with Pluggable Port Modules [PPM]) (not supported on the ONS 15327).
|
OPR-ALS:[<TID>]:<AID>:<CTAG>[::::];
Restarts the laser of an OC-N facility and in general for all the facilities that support the ALS feature. (ONS 15454, ONS 15310-CL, ONS 15310-MA).
|
RMV-<MOD2>:[<TID>]:<AID>:<CTAG>[::];
Removes a facility from service.
|
RST-<MOD2>:[<TID>]:<AID>:<CTAG>::::[<PST>],[<SST>];
Provisions a facility in service.
|
RTRV-<MOD1FCPAYLOAD>:[<TID>]:<AID>:<CTAG>[::::];
Retrieves the attributes related with the fibre channel (FC) port (ONS 15454 only).
Output format:
SID DATE TIME M CTAG COMPLD "<AID>:,,[<ROLE>],[<STATUS>]:LINKRATE=<LINKRATE>,LINKSTATE=<LINKSTATE>, [LINKRCVRY=<LINKRCVRY>],[DISTEXTN=<DISTEXTN>], [LINKCREDITS=<LINKCREDITS>],[MFS=<MFS>],[ENCAP=<ENCAP>],[NAME=<NAME>], [SOAK=<SOAK>],[SOAKLEFT=<SOAKLEFT>],[FREQ=<FREQ>],[LOSSB=<LOSSB>]: <PST_PSTQ>,[<SST>]"
;
|
RTRV-<MOD1FICONPAYLOAD>:[<TID>]:<AID>:<CTAG>;
Retrieves the fibre channel specific settings for ports which have been configured to carry FICON traffic (ONS 15454 only).
Output format:
SID DATE TIME M CTAG COMPLD "<AID>:,,[<ROLE>],[<STATUS>]:[LINKRATE=<LINKRATE>],[LINKSTATE=<LINKSTATE>], [LINKRCVRY=<LINKRCVRY>],[DISTEXTN=<DISTEXTN>], [LINKCREDITS=<LINKCREDITS>],[MFS=<MFS>],[ENCAP=<ENCAP>],[NAME=<NAME>], [SOAK=<SOAK>],[SOAKLEFT=<SOAKLEFT>],[FREQ=<FREQ>],[LOSSB=<LOSSB>]: <PST_PSTQ>,<SST>" ;
|
RTRV-<OCN_TYPE>:[<TID>]:<AID>:<CTAG>[::::];
Retrieves the attributes and state of an OC-N facility (not supported on the ONS 15327).
Output format:
SID DATE TIME M CTAG COMPLD "<AID>:,,[<ROLE>],[<STATUS>]:[DCC=<DCC>],[AREA=<AREA>],[TMGREF=<TMGREF>], [SYNCMSG=<SYNCMSG>],[SENDDUS=<SENDDUS>],[PJMON=<PJMON>], [SFBER=<SFBER>],[SDBER=<SDBER>],[MODE=<MODE>],[WVLEN=<WVLEN>], [RINGID=<RINGID>],[BLSRTYPE=<BLSRTYPE>],[MUX=<MUX>],[UNIC=<UNIC>], [CCID=<CCID>],[NBRIX=<NBRIX>],[SOAK=<SOAK>],[SOAKLEFT=<SOAKLEFT>], [SSMRCV=<SSMRCV>],[OSPF=<OSPF>],[LDCC=<LDCC>],[NAME=<NAME>], [LBCL=<LBCL>],[OPT=<OPT>],[OPR=<OPR>],[EXPTRC=<EXPTRC>],[TRC=<TRC>], [TRCMODE=<TRCMODE>],[TRCFORMAT=<TRCFORMAT>],[ADMSSM=<ADMSSM>], [SENDDUSFF=<SENDDUSFF>],[AISONLPBK=<AISONLPBK>],[FREQ=<FREQ>], [LOSSB=<LOSSB>],[FOREIGNFEND=<FOREIGNFEND>], [FOREIGNIPADDRESS=<FOREIGNIPADDRESS>],:<PSTPSTQ>,[<SSTQ>]" ;
|
RTRV-10GIGE:[<TID>]:<AID>:<CTAG>[::::];
Retrieves the 10 Gigabit per second specific parameters for the port (ONS 15454 only).
Output format:
SID DATE TIME M CTAG COMPLD "<AID>:,,[<ROLE>],[<STATUS>]:[NAME=<NAME>],[MACADDR=<MACADDR>], [LBCL=<LBCL>],[OPT=<OPT>],[OPR=<OPR>],[FREQ=<FREQ>],[LOSSB=<LOSSB>]: <PSTPSTQ>,[<SST>]" ;
|
RTRV-ALS:[<TID>]:<AID>:<CTAG>[::::];
Retrieves the ALS attributes of an OC-N facility and all facilities that support the ALS feature (ONS 15454, ONS 15310-CL, ONS 15310-MA).
Output format:
SID DATE TIME M CTAG COMPLD "<AID>,<AIDTYPE>::[ALSMODE=<ALSMODE>],[ALSRCINT=<ALSRCINT>], [ALSRCPW=<ALSRCPW>],[LSRSTAR=<LSRSTAR>]" ;
|
RTRV-DS1:[<TID>]:<SRC>:<CTAG>[::::];
Retrieves the test access attributes on a DS1 layer of DS3XM card (ONS 15454 only).
Output format:
SID DATE TIME M CTAG COMPLD "<DS1AID>::[TACC=<TACC>],[TAPTYPE=<TAPTYPE>],[AISONLPBK=<AISONLPBK>], [MODE=<MODE>],[FMT=<FMT>" ;
|
RTRV-EC1:[<TID>]:<AID>:<CTAG>[::::];
Retrieves the facility status of an EC1 card (ONS 15454, ONS 15310-CL, ONS 15310-MA).
Output format:
SID DATE TIME M CTAG COMPLD "<AID>::[PJMON=<PJMON>],[LBO=<LBO>],[RXEQUAL=<RXEQUAL>],[SOAK=<SOAK>], [SOAKLEFT=<SOAKLEFT>],[SFBER=<SFBER>],[SDBER=<SDBER>],[NAME=<NAME>], [EXPTRC=<EXPTRC>],[TRC=<TRC>],[TRCMODE=<TRCMODE>], [TRCFORMAT=<TRCFORMAT>],[AISONLPBK=<AISONLPBK>]:<PSTPSTQ>,[<SSTQ>]" ;
|
RTRV-ESCON:[<TID>]:<AID>:<CTAG>;
Retrieves fibre channel specific settings for ports that have been configured to carry ESCON traffic (ONS 15454 only).
Output format:
SID DATE TIME M CTAG COMPLD "<AID>:,,[<ROLE>],[<STATUS>]:[ENCAP=<ENCAP>]" ;
|
RTRV-FAC:[<TID>]:<SRC>:<CTAG>[::::];
Retrieves the payload type of the facility. Only applicable to a facility with a provisionable type.
Output format:
SID DATE TIME M CTAG COMPLD "<SRC>::PAYLOAD=<PAYLOAD>:<PST_PSTQ>,[<SSTQ>]" ;
|
RTRV-FSTE:[<TID>]:<AID>:<CTAG>;
Retrieves the front end port information of fast (10/100 Mbps) Ethernet cards (ONS 15454, ONS 15310-CL, ONS 15310-MA).
Output format:
SID DATE TIME M CTAG COMPLD "<AID>::[ADMINSTATE=<ADMINSTATE>],[LINKSTATE=<LINKSTATE>],[MTU=<MTU>], [FLOWCTRL=<FLOWCTRL>],[DUPLEX=<DUPLEX>],[SPEED=<SPEED>],[FLOW=<FLOW>], [EXPDUPLEX=<EXPDUPLEX>],[EXPSPEED=<EXPSPEED>],[VLANCOS=<VLANCOS>], [IPTOS=<IPTOS>],[OPTICS=<OPTICS>],[NAME=<NAME>],[SOAK=<SOAK>], [SOAKLEFT=<SOAKLEFT>]:<PST_PSTQ>,[<SSTQ>]" ;
|
RTRV-G1000:[<TID>]:<AID>:<CTAG>;
Retrieves the G1000 facilities configuration (ONS 15454 and ONS 15327 only).
Output format:
SID DATE TIME M CTAG COMPLD "<AID>::[MFS=<MFS>],[FLOW=<FLOW>],[LAN=<LAN>],[OPTICS=<OPTICS>], [TRANS=<TRANS>],[TPORT=<TPORT>],[LOWMRK=<LOWMRK>], [HIWMRK=<HIWMRK>],[AUTONEG=<AUTONEG>],[ENCAP=<ENCAP>], [NAME=<NAME>],[SOAK=<SOAK>],[SOAKLEFT=<SOAKLEFT>]:<PST_PSTQ>,[<SSTQ>]" ;
|
RTRV-GFP:[<TID>]:<SRC>:<CTAG>;
Retrieves the Generic Framing Procedure (GFP) port information on the ONS 15310-CL/ONS 15310-MA ML-100T-8, ONS 15454 CE-100T-8, FC_MR-4, and CE-1000-4, and ONS 15600 ASAP-4cards.
Output format:
SID DATE TIME M CTAG COMPLD "<AID>::[FCS=<FCS>],[AUTOTHGFPBUF=<AUTOTHGFPBUF>],[GFPBUF=<GFPBUF>], [FILTER=<FILTER>]" ;
|
RTRV-GIGE:[<TID>]:<AID>:<CTAG>;
Retrieves the front end port information for the ONS 15454 ML1000-2, CE-1000-4 cards and ONS 15600 ASAP-4 cards.
Output format:
SID DATE TIME M CTAG COMPLD "<AID>:,,<ROLE>,<STATUS>:[ADMINSTATE=<ADMINSTATE>], [LINKSTATE=<LINKSTATE>],[MTU=<MTU>],[ENCAP=<ENCAP>], [FLOWCTRL=<FLOWCTRL>],[AUTONEG=<AUTONEG>],[HIWMRK=<HIWMRK>], [LOWMRK=<LOWMRK>],[OPTICS=<OPTICS>],[DUPLEX=<DUPLEX>],[SPEED=<SPEED>], [NAME=<NAME>],[FREQ=<FREQ>],[LOSSB=<LOSSB>],[SOAK=<SOAK>], [SOAKLEFT=<SOAKLEFT>]:<PST>,<SST>" ;
|
RTRV-POS:[<TID>]:<AID>:<CTAG>;
Retrieves the back end port information for the ML-series Ethernet cards when the back end port is working in POS mode.
Output format:
SID DATE TIME M CTAG COMPLD "<AID>::[ADMINSTATE=<ADMINSTATE>],[LINKSTATE=<LINKSTATE>],[MTU=<MTU>], [ENCAP=<ENCAP>],[NAME=<NAME>],[SOAK=<SOAK>],[SOAKLEFT=<SOAKLEFT>]: <PST_PSTQ>,[<SST>]" ;
|
RTRV-T1:[<TID>]:<AID>:<CTAG>[::::];
Retrieves the DS1 facilities configuration (not supported on the ONS 15600).
Output format:
SID DATE TIME M CTAG COMPLD "<AID>::[LINECDE=<LINECDE>],[FMT=<FMT>],[LBO=<LBO>],[TACC=<TAP>], [TAPTYPE=<TAPTYPE>],[SOAK=<SOAK>],[SOAKLEFT=<SOAKLEFT>],[SFBER=<SFBER>], [SDBER=<SDBER>],[NAME=<NAME>],[SYNCMSG=<SYNCMSG>], [SENDDUS=<SENDDUS>],[RETIME=<RETIME>],[AISONLPBK=<AISONLPBK>], [AISVONAIS=<AISVONAIS>],[AISONLOF=<AISONLOF>],[MODE=<MODE>], [SYNCMAP=<SYNCMAP>],[ADMSSM=<ADMSSM>],[PROVIDESYNC=<PROVIDESYNC>], [VTMAP=<VTMAP>],[INHFELPBK=<INHFELPBK>]:<PST_PSTQ>,[<SSTQ>]" ;
|
RTRV-T3:[<TID>]:<AID>:<CTAG>[::::];
Retrieves the facilities properties of a DS3, DS3I (on SONET) and a DS3 trans mux card (not supported on the ONS 15600).
Output format:
SID DATE TIME M CTAG COMPLD "<AID>::[FMT=<FMT>],[LINECDE=<LINECDE>],[LBO=<LBO>], [INHFELPBK=<INHFELPBK>],[TACC=<TAP>],[TAPTYPE=<TAPTYPE>],[SOAK=<SOAK>], [SOAKLEFT=<SOAKLEFT>],[SFBER=<SFBER>],[SDBER=<SDBER>],[NAME=<NAME>], [AISONLPBK=<AISONLPBK>]:<PST_PSTQ>,[<SSTQ>]" ;
|