cc/td/doc/product/ong/15400/r701docs
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table Of Contents

INIT Commands

15.1  INIT-REG-<MOD2>

15.2  INIT-SYS


INIT Commands


This chapter provides initialize (INIT) commands for the Cisco ONS 15454, ONS 15327, ONS 15310-CL, ONS 15310-MA, and ONS 15600.

15.1  INIT-REG-<MOD2>

(Cisco ONS 15454, ONS 15327, ONS 15310-CL, ONS 15310-MA, ONS 15600) Initialize Register for 10GFC, 10GIGE, 1GFC, 1GFICON, 2GFC, 2GFICON, CLNT, D1VIDEO, DS1, DV6000, E1, E3, E4, EC1, ESCON, ETRCLO, FSTE, G1000, GFPOS, GIGE, HDTV, ISC1, OC12, OC192, OC3, OC48, OCH, OMS, OTS, POS, STS1, STS12C, STS18C, STS192C, STS24C, STS36C, STS3C, STS48C, STS6C, STS9C, T1, T3, VC12, VC3, VT1, or VT2 (INIT-REG-<MOD2>) command initializes the performance monitoring (PM) registers.

Usage Guidelines

See Table 27-1 for supported modifiers by platform.


NoteThe time period is always the current time period, and the previous time period counts are not cleared; therefore, neither MONDAT nor MONTM are supported in this command.

Unless otherwise stated, DS1 cards are the only cards that support the RCV and TRMT directions.

INIT-REG-<MOD2> can also be used to initialize the remote monitoring (RMON)-managed raw data.


Category

Performance

Security

Provisioning

Input Format

INIT-REG-<MOD2>:[<TID>]:<AID>:<CTAG>::<MONTYPE>,,[<LOCN>],[<DIRN>],[<TMPER>]
[,,];

Input Examples

INIT-REG-OC3:CISCO:FAC-1-1:1234::CVL,,NEND,BTH,15-MIN;

Input Parameters

<AID>

Access identifier from the "ALL" section. All of the STS, VT1, Facility, and DS1 AIDs are supported.

<MONTYPE>

Monitored type. The parameter type is ALL_MONTYPE (monitoring type list).

AISSP

Alarm Indication Signal SecondsPath

ALL

All possible values

BBE-PM

OTN—Background Block Errors—Path Monitor Point

BBE-SM

OTN—Background Block Errors—Section Monitor Point

BBER-PM

OTN—Background Block Error Ratio—Path Monitor Point expressed as one tenth of a percentage.

BBER-SM

OTN—Background Block Error Ratio—Section Monitor Point expressed as one tenth of a percentage.

BIEC

FEC—Bit Errors Corrected

CGV

8B10B—Code Group Violations

CSSP

Controlled Slip Seconds—Path (DSXM-12 FDL/T1.403 PM count)

CVCPP

Coding Violations—CP-Bit Path

CVL

Coding Violations—Line

CVP

Coding Violations—Path

CVS

Coding Violations—Section

CVV

Coding Violations—Section

DCG

8B10B—Data Code Groups

ESAP

Errored Second Type A-Path (DS3XM-12 DS1 PM count)

ESBP

Errored Second Type B-Path (DS3XM-12 DS1 PM count)

ESCPP

Errored Seconds—CPBit Path

ESL

Errored Seconds—Line

ESNPFE

Errored Second—Network Path (DS3XM-12 DS1 PM count)

ESP

Errored Seconds—Path

ES-PM

OTN—Errored Seconds—Path Monitor Point

ES-SM

OTN—Errored Seconds—Section Monitor Point

ESR

Errored Second—Ratio

ESR-PM

Errored Seconds Ratio—Path monitor Point expressed as one tenth of a percentage

ESR-SM

Errored Seconds Ratio—Section monitor Point expressed as one tenth of a percentage

ESS

Errored Seconds—Section

ESV

Errored Seconds—VT Path

etherStatsBroadcastPkts

The total number of good packets received that were directed to a multicast address

etherStatsCollisions

Number of transmit packets that are collisions

etherStatsCRCAlignErrors

The total number of packets received that have a length (excluding framing bits, but including FCS octets) of between 64 and 1518 octets

etherStatsDropEvents

Number of received frames dropped at the port level

etherStatsFragments

The total number of packets received that were less than 64 octets

etherStatsJabbers

The total number of packets received that are longer than 1518 octets

etherStatsOctets

The total number of octets of data

etherStatsOversizePkts

The total number of packets received that are longer than 1518 octets

etherStatsPkts

The total number of packets (including bad packets, broadcast packets, and multicast packets) received

etherStatsUndersizePkts

The total number of packets received that are less than 64 octets

FCP

Failure Count—Line

FC-PM

OTN—Failure Count—Path Monitor Point

FC-SM

OTN—Failure Count—Section Monitor Point

HP-AR

Availability Ratio

HP-BBE

High-Order Path Background Block Error

HP-BBER

High-Order Path Background Block Error Ratio

HP-EB

High-Order Path Errored Block

HP-ES

High-Order Path Errored Second

HP-ESA

High-Order Path Errored Seconds—A

HP-ESB

High-Order Path Errored Seconds—B

HP-ESR

High-Order Path Errored Second Ratio

HP-FC

High-Order Path Failure Count

HP-NPJC-PDET

High Order Path Negative Pointer Justification Count

HP-NPJC-PGEN

High Order Path, Negative Pointer Justification Count

HP-OI

Outage Intensity

HP-PJCDIFF

High Order Path Pointer Justification Count Difference

HP-PJCS-PDET

High Order Path Pointer Justification Count

HP-PJCS-PGEN

High Order Path Pointer Justification Count Seconds

HP-PPJC-PDET

High Order Path Positive Pointer Justification Count

HP-PPJC-PGEN

High Order Path, Positive Pointer Justification Count

HP-SEPI

The number of SEP events in available time

HP-SES

High-Order Path Severely Errored Seconds

HP-SESR

High-Order Path Severely Errored Second Ratio

HP-UAS

High-Order Path Unavailable Seconds

ifInBroadcastPkts

Number of broadcast packets received since the last counter reset

ifInDiscards

The number of inbound packets

ifInErrorBytePktss

Receive Error Byte

ifInErrors

The number of inbound packets (or transmission units) that contained errors

ifInFramingErrorPkts

Receive Framing Error

ifInJunkInterPkts

Receive Interpacket Junk

ifInMulticastPkts

Number of multicast packets received since the last counter reset

ifInOctets

Number of bytes transmitted since the last counter reset

ifInUcastPkts

Number of unicast packets received since the last counter reset

ifOutBroadcastPkts

Number of broadcast packets transmitted

ifOutDiscards

The number of outbound packets

ifOutErrors

The number of outbound packets (or transmission units) that could not be transmitted because of errors

ifOutMulticastPkts

Number of multicast packets transmitted

ifOutPayloadCrcErrors

Received payload cyclic redundancy check (CRC) errors

ifOutUcastPkts

Number of unicast packets transmitted

IOS

8B10—Idle Ordered Sets

IPC

Invalid Packet Count

LBCL-AVG

Average Laser Bias current in microA

LBCL-MAX

Maximum Laser Bias current in microA

LBCL-MIN

Minimum Laser Bias current in microA

LBCN

Normalized Laser Bias Current for OC3-8

LBCN-HWT

Laser Bias Current

LBCN-LWT

Laser Bias Current

LOSSL

Loss of Signal Seconds—Line

LP-BBE

Low-Order Path Background Block Error

LP-BBER

Low-Order Path Background Block Error Ratio

LP-EB

Low-Order Path Errored Block

LP-ES

Low-Order Path Errored Second

LP-ESA

Low-Order Path Errored Seconds—A

LP-ESB

Low-Order Path Errored Seconds—B

LP-ESR

Low-Order Path Errored Second Ratio

LP-FC

Low-Order Path Failure Count

LP-NPJC-DET

Low-Order Negative Pointer Justification Count, Detected

LP-NPJC-GEN

Low Order Negative Pointer Justification Count, Generated

LP-PPJC-DET

Low-Order Positive Pointer Justification Count, Detected

LP-PPJC-GEN

Low-Order Positive Pointer Justification Count, Generated

LP-SEP

Low-Order Path Severely Errored Period

LP-SEPI

Low-Order Path Severely Errored Period Intensity

LP-SES

Low-Order Path Severely Errored

LP-UAS

Low-Order Path Unavailable Seconds

MS-PSC

Protection switch count

MS-PSD

Protection switch duration

NIOS

8B10B—Non Idle Ordered Sets

NPJC-PDET

PPJC-PDET:Negative Pointer Justification

NPJC-PGEN

PPJC-PGEN:Negative Pointer Justification

OPR-AVG

Average Receive Power in tenths of a microW

OPR-MAX

Maximum Receive Power in tenths of a microW

OPR-MIN

Minimum Receive Power in tenths of a microW

OPRN

Normalized Optical Receive Power for OC3-8

OPRN-MAX

Maximum value for OPRN

OPRN-MIN

Minimum value for OPRN

OPT-AVG

Average Transmit Power in tenths of a microW

OPT-MAX

Maximum Transmit Power in tenths of a microW

OPT-MIN

Minimum Transmit Power in tenths of a microW

OPTN

Normalized value for Optical Power Transmitted for the OC3-8 card

OPTN-MAX

Maximum value for OPTN

OPTN-MIN

Minimum value for OPTN

OPWR-AVG

Optical Power—Average Interval Value in tenths of a dBm

OPWR-MAX

Optical Power—Maximum Interval Value in tenths of a dBm

OPWR-MIN

Optical Power—Minimum Interval Value in tenths of a dBm

PPJC-PDET

PPJC-PDET:Positive Pointer Justification

PPJC-PGEN

PPJC-PGEN:Positive Pointer Justification

PSC

Protection Switching Count

PSC-R

Protection Switching Count—Ring

PSC-S

Protection Switching Count—Span

PSC-W

Protection Switching Count—Working

PSD

Protection Switching Duration

PSD-R

Protection Switching Duration—Ring

PSD-S

Protection Switching Duration—Span

PSD-W

Protection Switching Duration—Working

SASCPP

Severely Errored Framing/Alarm Indication Signal (AIS) Seconds—CP-Bit Path

SASP

Severely Errored Framing/AIS Seconds Path

SEFS

Severely Errored Framing Seconds

SEFSP

Severely Errored Framing Seconds—Path (DS3XM-12 DS1 PM count)

SESCPP

Severely Errored Second—CP-Bit Path

SESL

Severely Errored Second—Line

SESNPFE

Severely Errored Second—Network Path (DS3XM-12 DS1 PM count)

SESP

Severely Errored Second—Path

SES-PM

OTN—Severely Errored Second—Path

SESR-PM

OTN—Severely Errored Second Ratio—Path Monitor Point expressed as one tenth of a percentage

SESR-SM

OTN—Severely Errored Second Ratio—Section Monitor Point expressed as one tenth of a percentage

SESS

Severely Errored Second—Section

SES-SM

OTN—Severely Errored Second—Section Monitor Point

SESV

Severely Errored Second—VT Path

UASCPP

Unavailable Second—CP-Bit Path

UASL

Unavailable Second—Line

UASNPFE

Unavailable Second—Network Path (DS3XM-12 DS1 PM count)

UASP

Unavailable Second—Path

UAS-PM

OTN—Unavailable Second—Path Monitor Point

UAS-SM

OTN—Unavailable Second—Section Monitor Point

UASV

Unavailable Second—VT Path

UNC-WORDS

FEC—Uncorrectable Words

VPC

Valid Packet Count

<LOCN>

Location associated with a particular command in reference to the entity identified by the AID. The parameter type is LOCATION, which is the location where the action is to take place.

FEND

Action occurs on the far end of the facility

NEND

Action occurs on the near end of the facility

<DIRN>

Direction relative to the entity identified by the AID. Defaults to ALL, which means that the command initializes all of the registers irrespective of the PM direction. The parameter type is DIRECTION (transmit and receive directions).

BTH

Both transmit and receive directions

RCV

Receive direction only

TRMT

Transmit direction only

<TMPER>

Accumulation time period for performance counters. A null value defaults to 15-MIN. Defaults to 15-MIN. The parameter type is TMPER, which is the accumulation time period for the performance management center.

1-DAY

Performance parameter accumulation interval length; every 24-hours. For SONET PM data, only one day of history data is available. For RMON managed PM data, seven days of history data are available.

1-HR

Performance parameter accumulation interval length; every 1 hour. This is only applicable to RMON managed PM data. There are 24 hours of history data available.

1-MIN

Performance parameter accumulation interval length; every 1 minute. This is only applicable to RMON managed PM data. There are 60 minutes of history available.

15-MIN

Performance parameter accumulation interval length; every 15 minutes. There are 32 15-MIN buckets of history data available for this accumulation interval length.

RAW-DATA

Performance parameter accumulation interval length; starting from the last time the counters were cleared. This is only applicable to RMON managed PMs.


15.2  INIT-SYS

(Cisco ONS 15454, ONS 15327, ONS 15310-CL, ONS 15310-MA, ONS 15600) The Initialize System (INIT-SYS) command initializes the specified card and its associated subsystems.

Usage Guidelines

The SLOT-ALL AID and the list AID are not allowed in this command.

Only one level of restart is supported in this command for the ONS 15454 and the ONS 15327.

It is important that the standby TCC2/TCC2P should be up and running fully standby for a period of time before this command is sent on the active TCC2/TCC2P. During this time, the system is vulnerable to traffic outages caused by timing disruptions or other causes.

The ONS 15310-CL supports the RESTART parameters for the 15310-CL-CTX, CE-100T-8, and ML-100T-8 cards only.

The ONS 15600 does not support soft resets on pluggable IO modules (PIMs).

If a card is hard reset, it has to be in one of the following states: OOS-MA, MT; OOS-MA, DSBLD; OOS-AUMA, MT; OOS-AUMA, DSBLD.

Category

System

Security

Maintenance

Input Format

INIT-SYS:[<TID>]:<AID>:<CTAG>::<PH>[,<CMDMDE=CMDMODE>];

Input Examples

INIT-SYS:HOTWATER:SLOT-8:201::1,CMDMDE=FRCD;

Input Parameters

<AID>

Access identifier from the "EQPT" section.

<PH>

The phase. PH is a required parameter for the ONS 15600 and ONS 15310-CL. PH is not supported on the ONS 15327. PH is supported on the CE-100T-8 on the ONS 15454. Phase is an integer.

1

Soft reset

2

Hard reset

<CMDMDE>

Command mode. Allows the user to override safety checks. CMDMDE is optional for the ONS 15600 and defaults to NORM. CMDMDE is not supported on the ONS 15454, ONS 15327, or ONS 15310-CL. The parameter type is CMDMDE, which forces the system to execute a given command regardless of any standing conditions. Normal mode is the default behavior for all commands, but you can specify FRCD to force the system to override a state where the command would normally be denied.

FRCD

Force the system to override a state where the command would normally be denied.

NORM

Execute the command normally. Do not override any conditions that could make the command fail.



hometocprevnextglossaryfeedbacksearchhelp

Posted: Mon Oct 29 08:07:30 PDT 2007
All contents are Copyright © 1992--2007 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.