5.1  CHG-ACCMD-<MOD_TACC>

5.2  CHG-EQPT


CHG Commands


This chapter provides change (CHG) commands for the Cisco ONS 15454, ONS 15327, ONS 15310-MA, and ONS 15600.

5.1  CHG-ACCMD-<MOD_TACC>

(Cisco ONS 15454, ONS 15327, ONS 15310-MA, ONS 15600) The Change Test Access Mode for the DS1, STS1, STS12C, STS192C, STS24C, STS3C, STS48C, STS6C, STS9C, T1, T3, VT1, or VT2 (CHG-ACCMD-<MOD_TACC>) command changes the test access (TACC) mode for the circuit being tested. This can be a change from monitoring the data to inserting data into the synchronous transport signal (STS). For more information about TACC, refer to the Cisco ONS SONET TL1 Reference Guide. See Table 27-1 for supported modifiers by platform.

Usage Guidelines

This command can only be applied to an existing test access point (TAP) connection.


Caution For this command to be applicable, you must first create the TAP using the ED-<MOD_PATH> command. Intrusive test access modes are traffic-affecting. If a facility/path is connected to a TAP in an intrusive test access mode, it is forced to go into the Out of Service, Maintenance (OOS-MT) state. The forced transition could be traffic-affecting. The present state of the facility/path is stored by the network element (NE) and is restored when the TAP connection is terminated. Test access connections are dropped automatically if the TL1 session is terminated or is timed out.


NoteIf there is no TAP connection, a DENY error message is returned.

If a requested condition already exists, a SRCN error message is returned.

If a requested access configuration is invalid, a SRAC error message is returned.

If a requested TAP does not exist, a RTEN error message is returned.


Category

Troubleshooting and Test Access

Security

Maintenance

Input Format

CHG-ACCMD-<MOD_TACC>:[<TID>]:<TAP>: <CTAG>::<MD>;

Input Example

CHG-ACCMD-STS1:CISCO:8:123::MONE;

Input Parameters

<TAP>

The test access point number. The TAP number must be an integer with a range of 1 to 999. It is a string.

Note This command only supports changing the mode for a single TAP number at a time.

<MD>

The test access mode. (SPLTE, SPLTF, LOOPE, and LOOPF require an external quasi-random signal [QRS] input signal.) Single facility access digroup (FAD) test access does not support MONEF, SPLTEF, and SPLTAB modes.

The parameter type is test access mode (TACC_MODE).

LOOPE

Splits both the A and B paths. Connect the line incoming from the E direction to the line outgoing in the E direction, and connect this looped configuration to the FAD. The line outgoing in the F direction will have a QRS connected, and the line incoming from the F direction will be terminated by the nominal characteristic impedance of the line. Intrusive test access mode.

LOOPF

Splits both the A and B paths. Connect the line incoming from F direction to the line outgoing in the F direction, and connect this looped configuration to the FAD. The line outgoing in the E direction will have a QRS connected, and the line incoming from the E direction will be terminated by the nominal characteristic impedance of the line. Intrusive test access mode.

MONE

Indicates that a monitor connection will be provided from the FAD to the A transmission path of the accessed circuit.

MONEF

Indicates that a monitor connection will be provided for the following:

From the FAD1 to a dual FAD (DFAD), or from the odd pair of a facility access path (FAP) to the A transmission path

From the FAD2 of the same DFAD or the even pair of a FAP, to the B transmission path of the accessed circuit

MONF

Indicates that a monitor connection will be provided from the FAD to the B transmission path of the accessed circuit.

SPLTA

Indicates that a connection will be provided from both the E and F sides of the A transmission path of the circuit under test to the FAD and split the A transmission path. Intrusive test access mode.

SPLTB

Indicates that a connection will be provided from both the E and F sides of the B transmission path of the circuit under test to the FAD and split the B transmission path. Intrusive test access mode.

SPLTE

Splits both the A and B paths and connect the E side of the accessed circuit to the FAD. The line outgoing in the F direction will have a QRS connected, the line incoming from the F direction will have a QRS connected, and the line incoming from the E direction will be terminated by the nominal characteristic impedance of the line. Intrusive test access mode.

SPLTEF

Splits both the A and B paths, and connect the E side of the accessed circuit to FAD1 and the F side to FAD2. Intrusive test access mode.

SPLTF

Splits both the A and B paths, and connect the F side of the accessed circuit to the FAD. The line outgoing in the E direction will have a QRS connected, the line incoming in the E direction will have a QRS connected, and the line incoming from the E direction will be terminated by the nominal characteristic impedance of the line. Intrusive test access mode.


5.2  CHG-EQPT

(Cisco ONS 15454) The Change Equipment (CHG-EQPT) command performs an in-service upgrade from low density (LD) electrical cards (DS1 [DS1-14, DS1N-14], DS3 [DS3-12, DS3N-12, DS3NE-12], EC1, and DS3XM-6) to high density (HD) electrical cards (DS1/E1-56, DS3/EC1-48, and DS3XM-12).

Usage Guidelines

For Software Release 6.0 and later, only limited upgrades are supported, such as upgrading one LD DS3-12 card to one HD DS3/EC1-48 card.

Optical (OC-N) card upgrades and downgrades are supported with the limitations of the MRC-12 card.

Compatible equipment types for card upgrade:

DS3XM-6 to DS3XM-12

DS-3/DS3-N/DS3-E/DS3N-E to DS3/EC1-48

DS-1/DS1-N to DS1/E1-56

Provisioning rules for card upgrade:

DS1-14 and DS1N-14 cards that are provisioned in Slot 1, 2, 3, 15, 16, or 17 should be upgraded to DS1/E1-56.

DS1-14 and DSN-14 cards that are provisioned in Slot 4, 5, 6, 12, 13, or 14 will fail when upgrading to DS1/E1-56.

DS3-12, DS3N-12, DS3E-12, and DS3N-12E cards that are provisioned in Slot 1, 2, 3, 15, 16, or 17 can be upgraded to DS3/EC1-48.

DS3-12, DS3N-12, DS3E-12, and DS3N-12E cards that are provisioned in Slot 4, 5, 6, 12, 13, or 14 will fail when upgrading to DS3/EC1-48.

Two upgradable cards provisioned in a 1:1 protection group cannot be upgraded.

Category

Equipment

Security

Maintenance

Input Format

CHG-EQPT:[<TID>]:<SRC>:<CTAG>::<EQPTTYPE>;

Input Example

CHG-EQPT::SLOT-1:1::DS3-EC1-48;

Input Parameters

<SRC>

The source access identifier from the "EQPT" section.

<EQPTTYPE>

The equipment type to be upgraded. The parameter type is EQUIPMENT_TYPE.

10DME-C

10DME-C card

10DME-L

10DME-L card

32DMX

(ONS 15454) 32 channel demultiplexer

32DMX-L

(ONS 15454) 32 channel demultiplexer unit for L-band

32DMX-O

(ONS 15454) 32 channel unidirectional optical demultiplexer

32MUX-O

(ONS 15454) 32 channel unidirectional optical multiplexer

32WSS

(ONS 15454) 32 channel optical wavelength selective switch

32WSS-L

(ONS 15454) 32 channel wavelength switch selector unit for L-band

4MD-xx.x

(ONS 15454) Optical multiplexer/demultiplexer with 4 channels

AD-1B-xx.x

(ONS 15454) Optical add/drop multiplexed (OADM) 1 band filter

AD-1C-xx.x

(ONS 15454) Optical add/drop multiplexed (OADM) 1 channel filter

AD-2C-xx.x

(ONS 15454) Optical add/drop multiplexed (OADM) 2 channel filter

AD-4B-xx.x

(ONS 15454) Optical add/drop multiplexed (OADM) 4 band filter

AD-4C-xx.x

(ONS 15454) Optical add/drop multiplexed (OADM) 4 channel filter

AIC-I

(ONS 15454) AIC-I card

ASAP

(ONS 15600) Any service any port carrier card with 4 PIM slots

CE-1000-4

(ONS 15454) CE-1000-4 card

CE-100T-8

(ONS 15454, ONS 15310-CL, ONS 15310-MA) Eight port 100T card

CTX2500

(ONS 15310-MA) CTX2500 card

DS1

(ONS 15454) DS1 card

DS1-28/DS3-EC1-3

(ONS 15310-MA) DS1-28/DS3-EC1-3 card

DS1-84/DS3-EC1-3

(ONS 15310-MA) DS1-84/DS3-3 card

DS1/E1-56

(ONS 15454) DS1/E1-56 card

DS1N

(ONS 15454) DS1N card

DS3

(ONS 15454) DS3 card

DS3/EC1-48

(ONS 15454) DS3/EC1-48 card

DS3i-N-12

(ONS 15454) DS3i-N-12 card

DS3N

(ONS 15454) DS3N card

DS3NE

(ONS 15454) DS3NE card

DS3XM-6

(ONS 15454) DS3XM-6 card

DS3XM-12

(ONS 15454) DS3XM-12 card

E1000-2

(ONS 15454) E1000-2 card

E1000-2-G

(ONS 15454) E1000-2-G card

E100T

(ONS 15454) E100T card

EC1

(ONS 15454) EC1 card

FC_MR-4

(ONS 15454) FC_MR-4 card

FILLER-CARD

Blank Filler card

G1000-2

(ONS 15327) Two port G1000 card

G1K-4

(ONS 15454) Four port G1000 card

MIC A

(ONS 15327) MIC A card

MIC B

(ONS 15327) MIC B card

ML100T-8

(ONS 15310-CL, ONS 15310-MA) Mapper card

ML1000-2

(ONS 15454) ML-Series two port gigabit Ethernet card

ML100T-12

(ONS 15454) ML-Series 12 port FSTE card

ML100X-8

(ONS 15454) Eight port 100T card with optical interface

MMU

(ONS 15454) Multiring/mesh upgrade unit

MRC-12

(ONS 15454) 12 port multirate optical card

MXP_2.5G_10E

(ONS 15454) 2.5-Gbps-10-Gbps Muxponder-100 GHz-Tunable xx.xx-xx.xx card

MXP_2.5G_10E_L

(ONS 15454) 2.5-Gbps-10-Gbps Muxponder-100 GHz-Tunable xx.xx-xx.xx card for L-band

MXP_2.5G_10E_C

(ONS 15454) 2.5-Gbps-10-Gbps Muxponder-100 GHz-Tunable xx.xx-xx.xx card for C-band

MXP_2.5G_10G

(ONS 15454) 2.5-Gbps-10-Gbps muxponder-100 GHz-tunable xx.xx-xx.xx card

MXP_MR_2.5G

(ONS 15454) 2.5-Gbps multirate muxponder-100 GHz-tunable 15xx.xx-15yy.yy card

MXPP_2.5G_10G

(ONS 15454) 2.5-Gbps-10-Gbps muxponder-protected-100 GHz-tunable xx.xx-xx.xx card

MXPP_MR_2.5G

(ONS 15454) 2.5-Gbps multirate muxponder-protected-100 GHz-tunable 15xx.xx-15yy.yy card

OC3

(ONS 15454, ONS 15327) OC-3 card

OC3-8

(ONS 15454) Eight port OC-3 card

OC12

(ONS 15454, ONS 15327) OC-12 card

OC12-4

(ONS 15454) Four port OC-12 card

OC48

(ONS 15454, ONS 15327, ONS 15600) OC-48 card

OC48-16

(ONS 15454) 16 port OC-48 card

OC192

(ONS 15454, ONS 15600) OC-192 card

OC192-4

(ONS 15454) Four port OC-192 card

OC192-XFP

(ONS 15454) One port OC-192 XFP

OPT-AMP-L

(ONS 15454) Optical preamplifier unit for L-Band

OPT-BST

(ONS 15454) Optical booster amplifier

OPT-BST-L

(ONS 15454) Optical booster unit for L-Band

OPT-PRE

(ONS 15454) Optical preamplifier

OSC-CSM

(ONS 15454) Optical service channel (OSC) with combiner/separator Module (SCM)

OSCM

(ONS 15454) Optical service channel module

PIM-1

(ONS 15600) One port pluggable interface module

PIM-4

(ONS 15600) Four port pluggable interface module

PPM-1

(ONS 15454, ONS 15600, ONS 15310-CL, ONS 15310-MA) Pluggable port module with one SFP port

SHELF

Shelf entity

SSXC

(ONS 15600) Cross-connect card

TCC

(ONS 15454) TCC card

TXP_MR_10E

(ONS 15454) 10-Gbps multirate transponder-100-GHz-tunable xx.xx-xx.xx card

TXP_MR_10E_C

(ONS 15454) 10-Gbps multirate transponder-100-GHz-tunable xx.xx-xx.xx card for C-band

TXP_MR_10E-L

(ONS 15454) 10-Gbps multirate transponder-100-GHz-tunable xx.xx-xx.xx card for L-band

TXP_MR_10G

(ONS 15454) 10-Gbps multirate transponder-100-GHz-tunable xx.xx-xx.xx card

TXP_MR_2.5G

(ONS 15454) 2.5-Gbps multirate transponder-100-GHz-tunable xx.xx-xx.xx card

TXPP_MR_2.5G

(ONS 15454) 2.5-Gbps multirate transponder-protected-100-GHz-tunable xx.xx-xx.xx card

UNKNOWN

Unknown equipment type

UNPROVISIONED

Unprovisioned type

XC10G

(ONS 15454) XC10G card

XCVT

(ONS 15454) XCVT card

XC-VXC-10G

(ONS 15454) XC-VXC-10G card

XTC

(ONS 15327) XTC card



hometocprevnextglossaryfeedbacksearchhelp

Posted: Mon Oct 29 07:53:39 PDT 2007
All contents are Copyright © 1992--2007 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.