Table Of Contents
B.1.3 Cisco Transport Controller
B.1.8 EIA Interface (ANSI only)
B.1.9 BITS Interface (ANSI only)
B.1.12 System Environmental Specifications
B.2 General Card Specifications
B.3 Common Control Card Specifications
B.3.1 TCC2 Card Specifications
B.3.2 TCC2P Card Specifications
B.3.3 AIC-I Card Specifications
B.3.4 AEP Specifications (ANSI only)
B.3.5 MIC-A/P FMEC Specifications (ETSI only)
B.3.6 MIC-C/T/P FMEC Specifications (ETSI only)
B.4.1 OSCM Card Specifications
B.4.2 OSC-CSM Card Specifications
B.4.3 OPT-PRE Amplifier Card Specifications
B.4.4 OPT-BST Amplifier Card Specifications
B.4.5 OPT-BST-E Amplifier Card Specifications
B.4.6 32MUX-O Card Specifications
B.4.7 32DMX-O Card Specifications
B.4.8 32DMX Card Specifications
B.4.9 4MD-xx.x Card Specifications
B.4.10 AD-1C-xx.x Card Specifications
B.4.11 AD-2C-xx.x Card Specifications
B.4.12 AD-4C-xx.x Card Specifications
B.4.13 AD-1B-xx.x Card Specifications
B.4.14 AD-4B-xx.x Card Specifications
B.4.15 32WSS Card Specifications
B.5 Transponder and Muxponder Card Specifications
B.5.1 TXP_MR_10G Card Specifications
B.5.2 MXP_2.5G_10G Card Specifications
B.5.3 TXP_MR_2.5G and TXPP_MR_2.5G Card Specifications
B.5.4 MXP_MR_2.5G and MXPP_MR_2.5G Card Specifications
B.5.5 MXP_2.5G_10E Card Specifications
B.5.6 TXP_MR_10E Card Specifications
SFP Port Cabling Specifications
B.7.1 XFP Port Cabling Specifications
Hardware Specifications
This appendix contains hardware and software specifications for the ONS 15454 ANSI and ETSI shelf assemblies and cards.
Note Unless otherwise specified, "ONS 15454" refers to both ANSI and ETSI shelf assemblies.
B.1 Shelf Specifications
This section provides specifications for shelf bandwidth; a list of topologies; Cisco Transport Controller (CTC) specifications; the LAN, TL1, modem, and alarm specifications; timing, power, and environmental specifications; and shelf dimensions.
B.1.1 Bandwidth
The ONS 15454 has the following bandwidth specifications:
•Total bandwidth: 240 Gbps
•Data plane bandwidth: 160 Gbps
•SONET/SDH plane bandwidth: 80 Gbps
B.1.2 Configurations
The ONS 15454 can be configured for the following dense wavelength division multiplexing (DWDM) topologies:
•Hubbed rings
•Multihubbed rings
•Point-to-point
•Linear
•Linear with optical add/drop multiplexing (OADM)
B.1.3 Cisco Transport Controller
CTC, the ONS 15454 craft interface software, has the following specifications:
•10BaseT
•Advanced Timing, Communications, and Control (TCC2/TCC2P) card access: RJ-45 connector
•Backplane access: LAN pin field (ANSI only)
•Front Mount Electrical Connection (FMEC) access: LAN connector on MIC-C/T/P faceplate (ETSI only)
B.1.4 External LAN Interface
The ONS 15454 external LAN interface has the following specifications:
•10BaseT Ethernet
•Backplane access: LAN pin field (ANSI only)
•FMEC access: LAN connector on MIC-C/T/P faceplate (ETSI only)
B.1.5 TL1 Craft Interface
The ONS 15454 TL1 craft interface has the following specifications:
•Speed: 9600 bps
•TCC2/TCC2P access: EIA/TIA-232 DB-9 type connector
•Backplane access: CRAFT pin field (ANSI only)
B.1.6 Modem Interface
The ONS 15454 modem interface has the following specifications:
•Hardware flow control
•TCC2/TCC2P: EIA/TIA-232 DB-9 type connector
B.1.7 Alarm Interface
The ONS 15454 alarm interface has the following specifications:
•ETSI
–Visual: Critical, Major, Minor, Remote
–Audible: Critical, Major, Minor, Remote
–FMEC access: 62-Pin DB connector on MIC-A/P faceplate
–Alarm inputs: Common 32-VDC output for all alarm-inputs, closed contact limited to 2 mA
–Control outputs: Open contact maximum 60 VDC, closed contact maximum 100 mA
•ANSI
–Visual: Critical, Major, Minor, Remote
–Audible: Critical, Major, Minor, Remote
–Backplane access: Alarm pin fields
–Alarm contacts: 0.045 mm, -48 V, 50 mA
B.1.8 EIA Interface (ANSI only)
The ONS 15454 electrical interface assembly (EIA) interface has the following specifications:
•SMB: AMP #415504-3 75-ohm, 4-leg connectors
•BNC: Trompeter #UCBJ224 75-ohm 4 leg connector (King or ITT are also compatible)
•AMP Champ: AMP#552246-1 with #552562-2 bail locks
B.1.9 BITS Interface (ANSI only)
The ONS 15454 building integrated timing supply (BITS) interface has the following specifications:
•2 DS-1 BITS inputs
•2 derived DS-1 outputs
•Backplane access: BITS pin field
B.1.10 System Timing
The ONS 15454 ANSI has the following system timing specifications:
•Stratum 3 per Telcordia GR-253-CORE
•Free running accuracy: +/- 4.6 ppm
•Holdover stability: 3.7 x 10-7 per day, including temperature (< 255 slips in first 24 hours)
•Reference: External BITS, line, internal
The ONS 15454 ETSI has the following system timing specifications:
•Stratum 3E, per ITU-T G.813
•Free running accuracy: +/- 4.6 ppm
•Holdover stability: 3.7 exp -7 per day, including temperature (< 255 slips in first 24 hours)
•Reference: External BITS, line, internal
B.1.11 System Power
The ONS 15454 ANSI has the following power specifications:
•Input power: -48 VDC
•Power consumption: 55 W (fan tray only); 650 W (maximum draw with cards)
•Power requirements: -40.5 to -57 VDC
•Power terminals: #6 Lug
•ANSI shelf: 100-A fuse panel (minimum 30 A fuse per shelf)
HD shelf: 100-A fuse panel (minimum 35 A fuse per shelf)The ONS 15454 ETSI has the following power specifications:
•Input voltage: -48 VDC
•Power consumption: Configuration dependent, 53 W for fan tray; 650 W (maximum draw with cards)
•Power requirements:
–Nominal: -48 VDC
–Tolerance limits: -40.5 to -57.0 VDC
•Power terminals: 3WK3 Combo-D power cable connector (MIC-A/P and MIC-C/T/P faceplates)
•Fusing: 100 A fuse panel; minimum 30 A fuse per shelf
B.1.12 System Environmental Specifications
The ONS 15454 ANSI has the following environmental specifications:
•Operating temperature: 32 to +131 degrees Farenheit (0 to +55 degrees Celsius); -40 to +139 degrees Farenheit (-40 to +65 degrees Celsius) with industrial temperature rated cards
•Operating humidity: 5 to 95 percent, noncondensing
The ONS 15454 ETSI has the following environmental specifications:
•Operating temperature: 32 to 104 degrees Fahrenheit (0 to +40 degrees Celsius)
•Operating humidity: 5 to 95 percent, noncondensing
B.1.13 Dimensions
The ONS 15454 ANSI shelf assembly has the following dimensions:
•Height: 18.5 in. (40.7 cm)
•Width: 19 or 23 in. (41.8 or 50.6 cm) with mounting ears attached
•Depth: 12 in. (26.4 cm) (5 in. or 12.7 cm projection from rack)
•Weight: 55 lb (24.947 kg) empty
The ONS 15454 ETSI shelf assembly has the following dimensions:
•Height: 616.5 mm (24.27 in.)
•Width: 535 mm (17 in.) without mounting ears attached
•Depth: 280 mm (11.02 in.)
•Weight: 26 kg empty (57.3 lb)
B.2 General Card Specifications
This section provides power specifications and temperature ranges for all ONS 15454 cards.
B.2.1 Power
Table B-1 provides power consumption information for the ONS 15454 cards.
Table B-1 Individual Card Power Requirements
Card Type Card Name Watts Amperes at -48 V BTU/Hr. Common Control CardsTCC2/TCC2P
19.20
0.4
66.8
AIC-I
4.8
0.1
15.3
AEP
3
(from +5 VDC from AIC-I)
10.2
MIC-A/P
0.13
via TCC2/TCC2P
—
MIC-C/T/P
0.38
via TCC2/TCC2P
—
DWDM CardsOSCM
Nominal 23
Maximum 26
Nominal 0.48
Maximum 0.54
Nominal 78.48
Maximum 88.71
OSC-CSM
Nominal 24
Maximum 27
Nominal 0.5
Maximum 0.56
Nominal 81.89
Maximum 92.12
OPT-PRE
Minimum 25
Nominal 30
Maximum39
Minimum 0.52
Nominal 0.5
Maximum 0.81
Minimum 85.3
Nominal 102.36
Maximum 88.71
OPT-BST
Nominal 30
Maximum 39
Nominal 0.63
Maximum 0.81
Nominal 102.36
Maximum 88.71
OPT-BST-E
Nominal 30
Maximum 39
Nominal 0.63
Maximum 0.81
Nominal 102.36
Maximum 88.71
32MUX-O
Nominal 16
Maximum 25
Nominal 0.33
Maximum 0.52
Nominal 54.59
Maximum 85.3
32DMX-O
Nominal 16
Maximum 25
Nominal 0.33
Maximum 0.52
Nominal 54.59
Maximum 85.3
32DMX
Nominal 15
Maximum 25
Nominal 0.31
Maximum 0.52
Nominal 51.21
Maximum 85
4MD-xx.x
Nominal 17
Maximum 25
Nominal 0.35
Maximum 0.52
Nominal 58.0
Maximum 85.3
AD-1C-xx.x
Nominal 17
Maximum 25
Nominal 0.35
Maximum 0.52
Nominal 58.0
Maximum 85.3
AD-2C-xx.x
Nominal 17
Maximum 25
Nominal 0.35
Maximum 0.52
Nominal 58.0
Maximum 85.3
AD-4C-xx.x
Nominal 17
Maximum 25
Nominal 0.35
Maximum 0.52
Nominal 58.0
Maximum 85.3
DWDM Cards
AD-1B-xx.x
Nominal 17
Maximum 25
Nominal 0.35
Maximum 0.52
Nominal 58.0
Maximum 85.3
AD-4B-xx.x
Nominal 17
Maximum 25
Nominal 0.35
Maximum 0.52
Nominal 58.0
Maximum 85.3
32WSS
Nominal 50
Maximum 65
Nominal 1.04
Maximum 1.35
Nominal 170
Maximum 221
Transponder and Muxponder CardsTXP_MR_10G
35.001
0.73
119.5
TXP_MR_10E
Nominal 40
Maximum 50
Nominal 1.11
Maximum 1.04
Nominal 136.6
Maximum 170.7
TXP_MR_2.5G
35.001
0.73
119.5
TXPP_MR_2.5G
501
1.04
170.5
MXP_2.5G_10G
501
1.04
170.7
MXP_2.5G_10E
Nominal 40
Maximum 50
Nominal 1.11
Maximum 1.04
Nominal 136.6
Maximum 170.7
MXP_MR_2.5G
Nominal 50
Maximum 60
Nominal 1.04
Maximum 1.25
Nominal 170.7
Maximum 204
MXPP_MR_2.5G
Nominal 50
Maximum 60
Nominal 1.04
Maximum 1.25
Nominal 170.7
Maximum 204
1 Calculated power; measured power was not available at the time of publication.
B.2.2 Temperature
Table B-2 provides temperature ranges and product names for ONS 15454 cards.
Note The I-Temp symbol is displayed on the faceplate of an I-Temp compliant card. A card without this symbol is C-Temp compliant.
B.3 Common Control Card Specifications
This section provides specifications for the TCC2, TCC2P, AIC, and AIC-I cards, the alarm expansion panel (AEP), and the MIC-A/P and MIC-C/T/P FMECs.
For compliance information, refer to the Cisco Optical Transport Products Safety and Compliance Information document.
B.3.1 TCC2 Card Specifications
The TCC2 card has the following specifications:
•CTC software
–Interface: EIA/TIA-232 (local craft access, on TCC2 faceplate)
–Interface: 10BaseT LAN (on TCC2 faceplate)
–Interface: 10BaseT LAN (through the backplane)
•Synchronization
–Stratum 3, per Telcordia GR-253-CORE
–Free running access: Accuracy +/- 4.6 ppm
–Holdover stability: 3.7 x 10-7 per day including temperature (< 255 slips in first 24 hours)
–Reference: External BITS, line, internal
•Supply voltage monitoring
–Both supply voltage inputs are monitored.
–Normal operation: -40.5 to -56.7 V
–Undervoltage: Major alarm
–Overvoltage: Major alarm
•Environmental
–Operating temperature: -40 to +149 degrees Fahrenheit (-40 to +65 degrees Celsius)
–Operating humidity: 5 to 95 percent, noncondensing
–Power consumption: 26.00 W, 0.54 A at -48 V, 88.8 BTU/hr
•Dimensions
–Height: 12.650 in. (321.3 mm)
–Width: 0.716 in. (18.2 mm)
–Depth: 9.000 in. (228.6 mm)
–Depth with backplane connector: 235 mm (9.250 in.)
–Weight not including clam shell: 0.7 kg (1.5 lb)
B.3.2 TCC2P Card Specifications
The TCC2P card has the following specifications:
•CTC software
–Interface: EIA/TIA-232 (local craft access, on TCC2P faceplate)
–Interface: 10BaseT LAN (on TCC2P faceplate)
–Interface: 10BaseT LAN (through the backplane)
•Synchronization
–Stratum 3, per Telcordia GR-253-CORE
–Free running access: Accuracy +/- 4.6 ppm
–Holdover stability: 3.7 * 10 exp - 7 per day including temperature (< 255 slips in first 24 hours)
–Reference: External BITS, line, internal
•Supply voltage monitoring
–Both supply voltage inputs are monitored.
–Normal operation: -40.5 to -56.7 V (in -48 VDC systems)
–Undervoltage: Major alarm
–Overvoltage: Major alarm
•Environmental
–Operating temperature: -40 to +149 degrees Fahrenheit (-40 to +65 degrees Celsius)
–Operating humidity: 5 to 95 percent, noncondensing
–Power consumption: 26.00 W, 0.54 A at -48 V, 88.8 BTU/hr
•Dimensions
–Height: 12.650 in. (321.3 mm)
–Width: 0.716 in. (18.2 mm)
–Depth: 9.000 in. (228.6 mm)
–Depth with backplane connector: 9.250 in. (235 mm)
–Weight not including clam shell: 1.5 lb (0.7 kg)
B.3.3 AIC-I Card Specifications
The AIC-I card has the following specifications:
•Alarm inputs
–Number of inputs: 12 without AEP, 32 with AEP
–Opto-coupler isolated
–Label customer provisionable
–Severity customer provisionable
–Common 32 V output for all alarm inputs
–Each input limited to 2 mA
–Termination: Wire-wrap on backplane without AEP, on AEP connectors with AEP
•Alarm outputs
–Number of outputs: 4 (user configurable as inputs) without AEP, 16 with AEP
–Switched by opto MOS (metal oxide semiconductor)
–Triggered by definable alarm condition
–Maximum allowed open circuit voltage: 60 VDC
–Maximum allowed closed circuit current: 100 mA
–Termination: Wire-wrap on backplane without AEP, on AEP connectors with AEP
•Express orderwire/local orderwire (EOW/LOW)
–ITU-T G.711, ITU-T G.712, Telcordia GR-253-CORE
–A-law, mu-law
Note Due to the nature of mixed coding, in a mixed-mode (A-law/mu-law) configuration, the orderwire is not ITU-T G.712 compliant.
–Orderwire party line
–Dual tone, multifrequency (DTMF) signaling
•User data channel (UDC)
–Bit rate: 64 kbps, codirectional
–ITU-T G.703
–Input/output impedance: 120 ohm
–Termination: RJ-11 connectors
•Data communications channel (DCC)
–Bit rate: 576 kbps
–EIA/TIA-485/V11
–Input/output impedance: 120 ohm
–Termination: RJ-45 connectors
•ACC connection for additional alarm interfaces
–Connection to AEP
•Power monitoring alarming states:
–Power failure (0 to -38 VDC)
–Undervoltage (-38 to -40.5 VDC)
–Overvoltage (beyond -56.7 VDC)
•Environmental
–Operating temperature: -40 to 149 degrees Fahrenheit (-40 to +65 degrees Celsius)
–Operating humidity: 5 to 95 percent, noncondensing
–Power consumption (including AEP, if used): 8.00 W, 0.17 A, 27.3 BTU/hr
•Dimensions
–Height: 12.650 in. (321.3 mm)
–Width: 0.716 in. (18.2 mm)
–Depth: 9.000 in. (228.6 mm)
–Weight: 1.8 lb (0.82 kg)
B.3.4 AEP Specifications (ANSI only)
The AEP has the following specifications:
•Alarm inputs
–Number of inputs: 32
–Optocoupler isolated
–Label customer provisionable
–Severity customer provisionable
–Common 32 V output for all alarm inputs
–Each input limited to 2 mA
–Termination: 50-pin AMP champ connector
•Alarm outputs
–Number of outputs: 16
–Switched by opto MOS
–Triggered by definable alarm condition
–Maximum allowed open circuit voltage: 60 VDC
–Maximum allowed closed circuit current: 100 mA
–Termination: 50-pin AMP champ connector
•Environmental
–Overvoltage protection: as in ITU-T G.703 Annex B
–Operating temperature: -40 to +65 degrees Celsius (-40 to +149 degrees Fahrenheit)
–Operating humidity: 5 to 95 percent, noncondensing
–Power consumption: 3.00 W max., from +5 VDC from AIC-I, 10.2 BTU/hr max.
•Dimensions of AEP board
–Height: 20 mm (0.79 in.)
–Width: 330 mm (13.0 in.)
–Depth: 89 mm (3.5 in.)
–Weight: 0.18 kg (0.4 lb)
B.3.5 MIC-A/P FMEC Specifications (ETSI only)
The MIC-A/P FMEC card has the following specifications:
•Power supply input BATTERY B
–System supply voltage: Nominal -48 VDC
Tolerance limits: -40.5 to -57.0 VDC–Connector: 3WK3 Combo-D power cable connector
•Alarm outputs
–Voltage (open contact): Maximum 60 VDC
–Current (closed contact): Maximum 250 mA
–Connector: 62-pin DB connector (common for inputs/outputs)
•Alarm inputs
–Voltage (open contact): Maximum 60 VDC
–Current (closed contact): Maximum 2 mA
–Connector: 62-pin DB connector (common for inputs/outputs)
•Environmental
–Operating temperature: -5 to +45 degrees Celsius (+23 to +113 degrees Fahrenheit)
–Operating humidity: 5 to 95 percent, noncondensing
–Power consumption: 0.13 W (provided by +5 V from the TCC2/TCC2P card), 0.44 BTU/hr
•Dimensions
–Height: 182 mm (7.165 in.)
–Width: 32 mm (1.25 in.)
–Depth: 92 mm (3.62 in.)
–Depth with backplane connector: 98 mm (3.87 in.)
–Weight not including clam shell: 0.2 kg (0.5 lb)
B.3.6 MIC-C/T/P FMEC Specifications (ETSI only)
The MIC-C/T/P FMEC card has the following specifications:
•Power supply input BATTERY A
–System supply voltage: Nominal -48 VDC
Tolerance limits: -40.5 to -57.0 VDC–Connector: 3WK3 Combo-D power cable connector
•Timing connector
–Frequency: 2.048 MHz +/-10 ppm
–Signal level: 0.75 to 1.5 V
–Impedance: 75 ohms +/-5 percent (switchable by jumper to high impedance > 3 kohms)
Note 120 ohms balanced impedance is possible with external matching cable.
–Cable attenuation: Up to 6 dB at 2 MHz
–Connectors: 1.0/2.3 miniature coax connector
•System management serial port:
–System management serial port craft interface
–Modem port (for future use)
–Connectors: 8-pin RJ-45
•System management LAN port connectors:
–Signal: IEEE 802.3 10BaseT
–Connectors: 8-pin RJ-45
•Environmental
–Operating temperature: -5 to +45 degrees Celsius (+23 to +113 degrees Fahrenheit)
–Operating humidity: 5 to 95 percent, noncondensing
–Power consumption: 0.38 W (provided by +5 V from the TCC2/TCC2P card), 1.37 BTU/hr
•Dimensions
–Height: 182 mm (7.165 in.)
–Width: 32 mm (1.25 in.)
–Depth: 92 mm (3.62 in.)
–Depth with backplane connector: 98 mm (3.87 in.)
–Weight not including clam shell: 0.2 kg (0.5 lb)
B.4 DWDM Card Specifications
This section provides specifications for the OSCM, OSC-CSM, OPT-PRE amplifier, OPT-BST amplifier, OPT-BST-E amplifier, 32MUX-O, 32DMX-O, 32DMX, 4MD-xx.x, AD-IC-xx.x, AD-2C-xx.x, AD-4C-xx.x, AD-1B-xx.x, AD-4B-xx.x, and 32WSS cards.
For compliance information, refer to the Cisco Optical Transport Products Safety and Compliance Information document.
B.4.1 OSCM Card Specifications
The OSCM card has the following specifications:
•Line
–Bit rate: 155 Mbps
–Code: Scrambled non-return to zero (NRZ)
–Loopback modes: None
–Connector: Duplex LC
–Compliance: Telcordia GR-253-CORE, ITU-T G.957
•Transmitter optical service channel (OSC) signal
–Maximum transmitter output power: -1 dBm
–Minimum transmitter output power: -5 dBm
–Nominal wavelength: 1510-nm +/-10 nm
–Variable optical attenuator (VOA) necessary in the transmit path to adjust the in-fiber optical power level
•Receiver OSC signal
–Maximum receiver level: -8 dBm at 10-10 bit error rate (BER)
–Minimum receiver level: -40 dBm at 10-10 BER
–Span budget: 40-dB span budget (about 150 km assuming fiber path loss equals 0.25 dB/km)
–Jitter tolerance: Telcordia GR-253/G.823 compliant
•Environmental
–Operating temperature:
C-Temp: -5 to +55 degrees Celsius (+23 to +131 degrees Fahrenheit)
–Operating humidity: 5 to 95 percent, noncondensing
•Dimensions
–Height: 12.65 in. (321.3 mm)
–Width: 0.92 in. (23.4 mm)
–Depth: 9.00 in. (228.6 mm)
B.4.2 OSC-CSM Card Specifications
The OSC-CSM card has the following specifications:
•Line
–Bit rate: 155 Mbps
–Code: Scrambled NRZ
–Loopback modes: None
–Connector: Duplex LC
–Compliance: Telcordia GR-253-CORE, ITU-T G.957
•Transmitter OSC signal
–Maximum transmitter output power: -2 dBm
–Minimum transmitter output power: -24 dBm
–Nominal wavelength: 1510-nm +/-10 nm
–VOA is necessary in the transmit path to adjust the in-fiber optical power level
•Receiver OSC signal
–Maximum receiver level: -8 dBm at 10-10 BER
–Minimum receiver level: -40 dBm at 10-10 BER
–Span loss budget: 35-dB span budget (approximately 140 km assuming that the fiber path loss is equal to 0.25 dB/km)
–Jitter tolerance: Telcordia GR-253/G.823 compliant
•Environmental
–Operating temperature:
C-Temp: -5 to +55 degrees Celsius (+23 to +131 degrees Fahrenheit)
–Operating humidity: 5 to 95 percent, noncondensing
•Dimensions
–Height: 12.65 in. (321.3 mm)
–Width: 0.92 in. (23.4 mm)
–Depth: 9.00 in. (228.6 mm)
B.4.3 OPT-PRE Amplifier Card Specifications
The OPT-PRE amplifier card has the following specifications:
•Optical characteristics:
–Total operating wavelength range: 1530 to 1561.3 nm
–Gain ripple (peak to valley): 1.5 dB
–Mid-access loss (MAL) range (for dispersion compensation unit [DCU]): 3 to 9 dB
–Gain range: 5 to 38.5 dBm in constant power mode, 5 to 28 dBm in constant gain mode
–Minimum gain (standard range): 5.0 dBm
Maximum gain (standard range with programmable gain tilt): 21 dBm
Maximum gain (extended range with uncontrolled gain tilt): 38.5 dBm
–Gain and power regulation over/undershoot: 0.5 dB
–Limited maximum output power: 17.5 dBm
–Maximum output power (with full channel load): 17 dB
–Minimum output power (with one channel): -1 dBm
–Input power (Pin) range at full channel load: -21.5 to 12 dBm
–Input power (Pin) range at single channel load: -39.5 to -6 dBm
–Noise figure at G3 21 dB = 6.5 dB
–OSC filter drop (channels) insertion loss maximum: 1 dB
–OSC filter drop (OSC) insertion loss maximum: 1.8 dB
–OSC filter add (OSC) insertion loss maximum: 1.3 dB
–Optical connectors: LC-UPC/2
•Environmental
–Operating temperature:
C-Temp: -5 to +55 degrees Celsius (+23 to +131 degrees Fahrenheit)
–Operating humidity: 5 to 85 percent, noncondensing
•Dimensions
–Height: 12.65 in. (332 mm)
–Width: 0.92 in. (24 mm)
–Depth: 9.00 in. (240 mm)
B.4.4 OPT-BST Amplifier Card Specifications
The OPT-BST amplifier card has the following specifications:
•Optical characteristics:
–Total operating wavelength range: 1530 to 1561.3 nm
–Gain ripple (peak to valley): 1.5 dB
–Gain range: 5 to 20 dBm with programmable gain tilt
–Gain and power regulation over/undershoot: 0.5 dB
–Limited maximum output power: 17.5 dBm
–Maximum output power (with full channel load): 17 dB
–Minimum output power (with one channel): -1 dBm
–Input power (Pin) range at full channel load: -3 to 12 dBm
–Input power (Pin) range at single channel load: -21 to -6 dBm
–Noise figure at G3 20 dB = 6 dB
–OSC filter drop (channels) insertion loss maximum: 1 dB
–OSC filter drop (OSC) insertion loss maximum: 1.8 dB
–OSC filter add (OSC) insertion loss maximum: 1.3 dB
–Optical connectors: LC-UPC/2
•Environmental
–Operating temperature:
C-Temp: -5 to +55 degrees Celsius (+23 to +131 degrees Fahrenheit)
–Operating humidity: 5 to 85 percent, noncondensing
•Dimensions
–Height: 12.65 in. (332 mm)
–Width: 0.92 in. (24 mm)
–Depth: 9.00 in. (240 mm)
B.4.5 OPT-BST-E Amplifier Card Specifications
The OPT-BST-E amplifier card has the following specifications:
•Optical characteristics:
–Total operating wavelength range: 1530 to 1561.3 nm
–Gain ripple (peak to valley): 1.8 dB
–Gain range: 8 to 23 dB with programmable gain tilt
–Extended gain range: 23 to 26 dB with gain tilt uncontrolled
–Gain and power regulation over/undershoot: 0.5 dB
–Limited maximum output power: 20.5 dBm
–Maximum output power (with full channel load): 20 dB
–Minimum output power (with one channel): -1 dBm
–Input power (Pin) range at full channel load: -6 to 12 dBm
–Input power (Pin) range at single channel load: -26 to -8 dBm
–Noise figure at G3 23 dB = 6 dB
–OSC filter drop (channels) insertion loss maximum: 1 dB
–OSC filter drop (OSC) insertion loss maximum: 1.8 dB
–OSC filter add (OSC) insertion loss maximum: 1.3 dB
–Optical connectors: LC-UPC/2
•Environmental
–Operating temperature:
C-Temp: -5 to +55 degrees Celsius (+23 to +131 degrees Fahrenheit)
–Operating humidity: 5 to 85 percent, noncondensing
•Dimensions
–Height: 12.65 in. (332 mm)
–Width: 0.92 in. (24 mm)
–Depth: 9.00 in. (240 mm)
B.4.6 32MUX-O Card Specifications
The 32 MUX-O card optical specifications are listed in Table B-3.
Note For power specifications, refer to the "16.1.7 Multiplexer, Demultiplexer, and OADM Card Interface Classes" section on page 16-6.
The 32MUX-O card has the following additional specifications:
•Environmental
–Operating temperature:
C-Temp: -5 to +55 degrees Celsius (+23 to +131 degrees Fahrenheit)
–Operating humidity: 5 to 95 percent relative humidity (RH)
•Dimensions
–Height: 12.65 in. (321.3 mm)
–Width: 1.84 in. (46.8 mm)
–Depth: 9.00 in. (228.6 mm)
B.4.7 32DMX-O Card Specifications
The 32DMX-O card optical specifications are listed in Table B-4.
Note For power specifications, see the "16.1.7 Multiplexer, Demultiplexer, and OADM Card Interface Classes" section on page 16-6.
The 32DMX-O card has the following additional specifications:
•Environmental
–Operating temperature:
C-Temp: -5 to +55 degrees Celsius (+23 to +131 degrees Fahrenheit)
–Operating humidity: 5 to 95 percent RH
•Dimensions
–Height: 12.65 in. (321.3 mm)
–Width: 1.84 in. (46.8 mm)
–Depth: 9.00 in. (228.6 mm)
B.4.8 32DMX Card Specifications
The 32DMX card optical specifications are listed in Table B-5.
Note For power specifications, see the "16.1.7 Multiplexer, Demultiplexer, and OADM Card Interface Classes" section on page 16-6.
The 32DMX channel plan is shown in Table B-6. All 32DMX client interfaces must comply with this plan.
The 32DMX card has the following additional specifications:
•Environmental
–Operating temperature:
C-Temp: -5 to +55 degrees Celsius (+23 to +131 degrees Fahrenheit)
–Operating humidity: 5 to 95 percent RH
•Dimensions
–Height: 12.65 in. (321.3 mm)
–Width: 0.92 in. (23.4 mm)
–Depth: 9.00 in. (228.6 mm)
B.4.9 4MD-xx.x Card Specifications
The 4MD-xx.x card optical specifications are listed in Table B-7.
Note For power specifications, see the "16.1.7 Multiplexer, Demultiplexer, and OADM Card Interface Classes" section on page 16-6.
The 4MD-xx.x card has the following additional specifications:
•Environmental
–Operating temperature:
C-Temp: -5 to +55 degrees Celsius (+23 to +131 degrees Fahrenheit)
–Operating humidity: 5 to 95 percent RH
•Dimensions
–Height: 12.65 in. (321.3 mm)
–Width: 0.92 in. (23.4 mm)
–Depth: 9.00 in. (228.6 mm)
B.4.10 AD-1C-xx.x Card Specifications
Table B-8 lists the AD-1C-xx.x optical specifications.
AD-1C-xx.x optical input and output power varies with amplifier output levels and the class of transponder interfaces used. See Table 16-3 on page 16-6 through Table 16-5 on page 16-8 for this information.
The AD-1C-xx.x card has the following additional specifications:
•Environmental
–Operating temperature:
C-Temp: -5 to +55 degrees Celsius (+23 to +131 degrees Fahrenheit)
–Operating humidity: Telcordia GR-63 5.1.1.3 compliant; 5 to 95 percent RH
•Dimensions
–Height: 12.650 in. (321.3 mm)
–Width: 0.92 in. (23.4 mm)
–Depth: 9.0 in. (228.6 mm)
B.4.11 AD-2C-xx.x Card Specifications
Table B-9 lists the AD-2C-xx.x optical specifications.
AD-2C-xx.x optical input and output power varies with amplifier output levels and the class of transponder interfaces used. See Table 16-3 on page 16-6 through Table 16-5 on page 16-8 for this information.
The AD-2C-xx.x has the following additional specifications:
•Environmental
–Operating temperature:
C-Temp: -5 to +55 degrees Celsius (+23 to +131 degrees Fahrenheit)
–Operating humidity: Telcordia GR-63 5.1.1.3 compliant; 5 to 95 percent RH
•Dimensions
–Height: 12.650 in. (321.3 mm)
–Width: 0.92 in. (23.4 mm)
–Depth: 9.0 in. (228.6 mm)
B.4.12 AD-4C-xx.x Card Specifications
Table B-10 lists the AD-4C-xx.x optical specifications.
Table B-10 AD-4C-xx.x Optical Specifications
Parameter Note Condition Min Max UnitChannel grid
See Table B-11. The channel plan for the AD-4C-xx.x card is identical to the channel plan for the AD-1B-xx.x card.
—
—
—
—
Trx filter shape
(-0.5 dB bandwidth)
TrxBW2All SOP and within whole operating temperature range
COM Rx—xx.xx Tx
COM Rx—yy.yy Tx
COM Rx—zz.zz Tx
COM Rx—kk.kk Tx
xx.xx Rx—COM Tx
yy.yy Rx—COM Tx+/-180
—
pm
Rfx filter shape
(-1 dB bandwidth)
RfxBW2All SOP and within whole operating temperature range
COM Rx—Exp Tx
Exp Rx—COM Tx—
—
pm
Insertion loss
(drop section)All SOP and within whole operating temperature range (two connectors included)
COM Rx—xx.xx Tx
—
5.5
dB
COM Rx—yy.yy Tx
—
5.0
dB
COM Rx—zz.zz Tx
—
4.5
dB
COM Rx—kk.kk Tx
—
4.1
dB
Insertion loss
(express section)VOA at minimum attenuation; all SOP and within whole operating temperature range (two connectors included)
COM Rx—Exp Tx
—
2.7
dB
Exp Rx—COM Tx
—
1.2
dB
Insertion loss
(add section)VOA at minimum attenuation; all SOP and within whole operating temperature range (two connectors included)
xx.xx Rx—COM Tx
—
3.9
dB
yy.yy Rx—COM Tx
—
4.3
dB
zz.zz Rx—COM Tx
—
4.5
dB
kk.kk Rx—COM Tx
—
4.9
dB
VOA dynamic range
—
—
30
—
dB
Maximum optical input power
—
—
300
—
mW
AD-4C-xx.x optical input and output power varies with amplifier output levels and the class of transponder interfaces used. See Table 16-3 on page 16-6 through Table 16-5 on page 16-8 for this information.
The AD-4C-xx.x has the following additional specifications:
•Environmental
–Operating temperature:
C-Temp: -5 to +55 degrees Celsius (+23 to +131 degrees Fahrenheit)
–Operating humidity: Telcordia GR-63 5.1.1.3 compliant; 5 to 95 percent RH
•Dimensions
–Height: 12.650 in. (321.3 mm)
–Width: 0.92 in. (23.4 mm)
–Depth: 9.0 in. (228.6 mm)
B.4.13 AD-1B-xx.x Card Specifications
Table B-11 lists the unit names, band IDs, channel IDs, frequencies, and wavelengths assigned to the eight versions of the AD-1B-xx.x card.
Table B-12 lists AD-1B-xx.x optical specifications.
Table B-12 AD-1B-xx.x Optical Specifications
Parameter Note Condition Min Max Unit-1 dB bandwidth
All SOP and within whole operating environmental range
COM Rx—Band Tx
Band Rx—COM Tx3.6
—
nm
-1 dB bandwidth
All SOP and within whole operating temperature range
COM Rx—Exp Tx
Exp Rx—COM TxRefer to Table B-13.
nm
Insertion loss
(drop section)All SOP and within whole operating environmental range; two connectors included, VOA set at minimum attenuation
COM Rx—Band Tx
—
3.0
dB
Insertion loss
(express section)All SOP and within whole operating environmental range; two connectors included
Exp Rx—COM Tx
—
1.6
dB
All SOP and within whole operating environmental range; two connectors included, VOA set at its minimum attenuation
COM Rx—Exp Tx
—
2.2
dB
Insertion loss
(add section)All SOP and within whole operating environmental range; two connectors included
Band Rx—COM Tx
—
2.2
dB
VOA dynamic range
—
—
30
—
dB
Maximum optical input power
—
—
300
—
mW
Table B-13 lists the range of wavelengths for the receive (express) band.
AD-1B-xx.x optical input and output power varies with amplifier output levels and the class of transponder interfaces used. See Table 16-3 on page 16-6 through Table 16-5 on page 16-8 for this information.
The AD-1B-xx.x card has the following additional specifications:
•Environmental
–Operating temperature:
C-Temp: -5 to +55 degrees Celsius (+23 to +131 degrees Fahrenheit)
–Operating humidity: Telcordia GR-63 5.1.1.3 compliant; 5 to 95 percent RH
•Dimensions
–Height: 12.650 in. (321.3 mm)
–Width: 0.92 in. (23.4 mm)
–Depth: 9.0 in. (228.6 mm)
B.4.14 AD-4B-xx.x Card Specifications
Table B-14 lists the unit names, band IDs, channel IDs, frequencies, and wavelengths assigned to the two versions of the card.
Table B-15 lists AD-4B-xx.x optical specifications.
Table B-15 AD-4B-xx.x Optical Specifications
Parameter Note Condition Min Max Unit-1 dB bandwidth
All SOP and within whole operating environmental range
COM Rx—Band Tx
Band Rx—COM Tx3.6
—
nm
-1 dB bandwidth
All SOP and within whole operating temperature range
COM Rx—Exp Tx
Exp Rx—COM TxRefer to Table B-16.
nm
Insertion loss
(drop section)All SOP and within whole operating environmental range; two connectors included, VOA set at minimum attenuation
COM Rx—Band Tx
30.3/46.1—
2.9
dB
COM Rx—Band Tx
34.2/50.1—
3.3
dB
COM Rx—Band Tx
38.1/54.1—
3.8
dB
COM Rx—Band Tx
42.1/58.1—
4.5
dB
Insertion loss
(express section)All SOP and within whole operating environmental range; two connectors included
Exp Rx—COM Tx
—
4.9
dB
All SOP and within whole operating environmental range; two connectors included, VOA set at its minimum attenuation
COM Rx—Exp Tx
—
3
dB
Insertion loss
(add section)All SOP and within whole operating environmental range; two connectors included
Band Rx 30.3/46.1—COM Tx
—
3.5
dB
Band Rx 34.2/50.1—COM Tx
—
2.8
dB
Band Rx 38.1/54.1—COM Tx
—
2.3
dB
Band Rx 42.1/58.1—COM Tx
—
1.8
dB
VOA dynamic range
—
—
30
—
dB
Maximum optical input power
—
—
300
—
mW
Table B-16 lists the range of wavelengths for the receive (express) band.
AD-4B-xx.x optical input and output power varies with amplifier output levels and the class of transponder interfaces used. See Table 16-3 on page 16-6 through Table 16-5 on page 16-8 for this information.
The AD-4B-xx.x has the following additional specifications:
•Environmental
–Operating temperature:
C-Temp: -5 to +55 degrees Celsius (+23 to +131 degrees Fahrenheit)
–Operating humidity: Telcordia GR-63 5.1.1.3 compliant; 5 to 95 percent RH
•Dimensions
–Height: 12.650 in. (321.3 mm)
–Width: 0.92 in. (23.4 mm)
–Depth: 9.0 in. (228.6 mm)
B.4.15 32WSS Card Specifications
The 32WSS card optical specifications are listed in Table B-17.
Note For power specifications, see the "16.1.7 Multiplexer, Demultiplexer, and OADM Card Interface Classes" section on page 16-6.
The 32WSS channel plan is shown in Table B-18. All 32WSS client interfaces must comply with this plan.
.
The 32WSS card has the following additional specifications:
•Environmental
–Operating temperature:
C-Temp: -5 to +55 degrees Celsius (+23 to +131 degrees Fahrenheit)
–Operating humidity: 5 to 95 percent RH
•Dimensions
–Height: 12.65 in. (321.3 mm)
–Width: 1.84 in. (46.8 mm)
–Depth: 9.00 in. (228.6 mm)
B.5 Transponder and Muxponder Card Specifications
This section provides specifications for the TXP_MR_10G, MXP_2.5G_10G, TXP_MR_2.5G, TXPP_MR_2.5G, MXP_MR_2.5G, MXPP_MR_2.5G, MXP_2.5G_10E, and TXP_MR_2.5G cards.
For compliance information, refer to the Cisco Optical Transport Products Safety and Compliance Information document.
B.5.1 TXP_MR_10G Card Specifications
The TXP_MR_10G card has the following specifications:
•Line (trunk side)
–Bit rate:
9.95328 Gbps for OC-192/STM-64
10.70923 Gbps with ITU-T G.709 Digital Wrapper/forward error correction (FEC)
10.3125 Gbps for 10 Gigabit Ethernet (GE)
11.095 Gbps with ITU-T G.709 Digital Wrapper/FEC over 10 GE
–Code: Scrambled NRZ
–Fiber: 1550-nm single-mode
–Maximum chromatic dispersion allowance: 1000 ps/nm
–Loopback modes: Terminal and facility
Caution You must use a 15-dB fiber attenuator (10 to 20 dB) when working with the TXP_MR_10G card in a loopback on the trunk port. Do not use direct fiber loopbacks with the TXP_MR_10G card. Using direct fiber loopbacks causes irreparable damage to the TXP_MR_10G card.
–Connectors: LC
–Compliance Telcordia GR-253-CORE, ITU-T G.707, ITU-T G.691
•Transmitter (trunk side)
–Maximum transmitter output power: +3.5 dBm
–Minimum transmitter output power: +2.5 dBm
–Transmitter: Lithium Niobate (LN) external modulator transmitter
–Wavelength stability (drift): +/- 25 picometers (pm)
Note An optical device on the card keeps the laser wavelength locked as closely as possible to the ITU nominal value. The allowed drift is +/- 25 pm.
•Currently available wavelengths and versions of TXP_MR_10G (16 card versions, each covering two wavelengths):
–1530.33 to 1531.12 nm (two wavelengths)
–1531.90 to 1532.68 nm (two wavelengths)
–1534.25 to 1535.04 nm (two wavelengths)
–1535.82 to 1536.61 nm (two wavelengths)
–1538.19 to 1538.98 nm (two wavelengths)
–1539.77 to 1540.56 nm (two wavelengths)
–1542.14 to 1542.94 nm (two wavelengths)
–1543.73 to 1544.53 nm (two wavelengths)
–1546.12 to 1546.92 nm (two wavelengths)
–1547.72 to 1548.51 nm (two wavelengths)
–1550.12 to 1550.92 nm (two wavelengths)
–1551.72 to 1552.52 nm (two wavelengths)
–1554.13 to 1554.94 nm (two wavelengths)
–1555.75 to 1556.55 nm (two wavelengths)
–1558.17 to 1558.98 nm (two wavelengths)
–1559.79 to 1560.61 nm (two wavelengths)
•Receiver (trunk side):
–Receiver input power (no FEC, unamplified, 23 dB optical signal-to-noise ratio [OSNR], BER 1 * 10 exp - 12): -8 to -21 dBm
–Receiver input power (no FEC, unamplified, 23 dB OSNR, at +/- 1000 ps/nm BER 1 * 10 exp - 12): -8 to -19 dBm
–Receiver input power (no FEC, amplified, 19 dB OSNR, BER 1 * 10 exp - 12): -8 to -20 dBm
–Receiver input power (no FEC, amplified, 19 dB OSNR, at +/- 1000 ps/nm BER 1 * 10 exp - 12):-8 to -18 dBm
–Receiver input power (FEC, unamplified, 23 dB OSNR, BER 8 * 10 exp - 5): -8 to -24 dBm
–Receiver input power (FEC, unamplified, 23 dB OSNR, at +/- 1000 ps/nm, BER 8 * 10 exp - 5): -8 to -22 dBm
–Receiver input power (FEC, amplified, 9 dB OSNR, BER 8 * 10 exp - 5): -8 to -18 dBm
–Receiver input power (FEC, unamplified, 11 dB OSNR, at +/- 800 ps/nm, BER 8 * 10 exp - 5): -8 to -18 dBm
•Line (client side)
–Bit rate: 9.95328 Gbps or 10.3125 Gbps
–Code: Scrambled NRZ
–Fiber: 1550-nm single-mode
–Maximum chromatic dispersion allowance: Compliant with SR-1 specification for OC-192. In the case of 10 GE, the allowance is up to 10 km of single-mode fiber (SMF) dispersion.
–Loopback modes: Terminal and facility
–Connectors: LC
–Compliance: Telcordia GR-253-CORE, ITU-T G.707, ITU-T G.697, 10GEBase-LR
•Transmitter (client side)
–Maximum transmitter output power: -1 dBm
–Minimum transmitter output power: -6 dBm
–Center wavelength: 1290 to 1330 nm
–Nominal wavelength: 1310 nm
–Transmitter: Distributed feedback (DFB) laser
•Receiver (client side)
–Maximum receiver level: -1 dBm at BER 1 * 10 exp - 12
–Minimum receiver level: -14 dBm at BER 1 * 10 exp - 12
–Receiver: avalanche photodiode (APD)
–Link loss budget: 8 dB minimum, at BER = 1 * 10 exp - 12
–Receiver input wavelength range: 1290 to 1605 nm
•Environmental
–Operating temperature: -5 to +55 degrees Celsius (+23 to +113 degrees Fahrenheit)
–Operating humidity: 5 to 95 percent, noncondensing
–Power consumption: 35.00 W, 0.73 A at -48 V, 119.5 BTU/hr
•Dimensions
–Height: 12.650 in. (321.3 mm)
–Width: 0.716 in. (18.2 mm)
–Depth: 9.000 in. (228.6 mm)
–Depth with backplane connector: 9.250 in. (235 mm)
–Weight not including clam shell: 3.1 lb (1.3 kg)
B.5.2 MXP_2.5G_10G Card Specifications
The MXP_2.5G_10G card has the following specifications:
•Line (trunk side)
–Bit rate:
9.95328 Gbps for OC-192/STM-64
10.70923 Gbps with ITU-T G.709 Digital Wrapper/FEC
–Code: Scrambled NRZ
–Fiber: 1550-nm single-mode
–Maximum chromatic dispersion allowance: 1000 ps/nm
–Loopback modes: Terminal and facility
Caution You must use a 20-dB fiber attenuator (15 to 25 dB) when working with the MXP_2.5G_10G card in a loopback on the trunk port. Do not use direct fiber loopbacks with the MXP_2.5G_10G card. Using direct fiber loopbacks causes irreparable damage to the MXP_2.5G_10G card.
–Connectors: LC
–Compliance: Telcordia GR-253-CORE, ITU-T G.707, ITU-T G.691
•Transmitter (trunk side)
–Maximum transmitter output power: +3.5 dBm
–Minimum transmitter output power: +2.5 dBm
–Transmitter: LN external modulator transmitter
–Wavelength stability (drift): +/- 25 picometers (pm)
Note An optical device on the card keeps the laser wavelength locked as closely as possible to the ITU nominal value. The allowed drift is +/- 25 pm.
•Currently available wavelengths and versions of MXP_2.5G_10G (16 card versions, each covering two wavelengths):
–1530.33 to 1531.12 nm (two wavelengths)
–1531.90 to 1532.68 nm (two wavelengths)
–1534.25 to 1535.04 nm (two wavelengths)
–1535.82 to 1536.61 nm (two wavelengths)
–1538.19 to 1538.98 nm (two wavelengths)
–1539.77 to 1540.56 nm (two wavelengths)
–1542.14 to 1542.94 nm (two wavelengths)
–1543.73 to 1544.53 nm (two wavelengths)
–1546.12 to 1546.92 nm (two wavelengths)
–1547.72 to 1548.51 nm (two wavelengths)
–1550.12 to 1550.92 nm (two wavelengths)
–1551.72 to 1552.52 nm (two wavelengths)
–1554.13 to 1554.94 nm (two wavelengths)
–1555.75 to 1556.55 nm (two wavelengths)
–1558.17 to 1558.98 nm (two wavelengths)
–1559.79 to 1560.61 nm (two wavelengths)
•Receiver (trunk side)
–Receiver input power (no FEC, unamplified, 23 dB OSNR, BER 1 * 10 exp - 12): -8 to -21 dBm
–Receiver input power (no FEC, unamplified, 23 dB OSNR, at +/- 1000 ps/nm BER 1 * 10 exp - 12): -8 to -19 dBm
–Receiver input power (no FEC, amplified, 19 dB OSNR, BER 1 * 10 exp - 12): -8 to -20 dBm
–Receiver input power (no FEC, amplified, 19 dB OSNR, at +/- 1000 ps/nm BER 1 * 10 exp - 12):-8 to -18 dBm
–Receiver input power (FEC, unamplified, 23 dB OSNR, BER 8 * 10 exp - 5): -8 to -24 dBm
–Receiver input power (FEC, unamplified, 23 dB OSNR, at +/- 1000 ps/nm, BER 8 * 10 exp - 5): -8 to -22 dBm
–Receiver input power (FEC, amplified, 9 dB OSNR, BER 8 * 10 exp - 5): -8 to -18 dBm
–Receiver input power (FEC, unamplified, 11 dB OSNR, at +/- 800 ps/nm, BER 8 * 10 exp - 5): -8 to -18 dBm
•Line (client side)
–Bit rate: 2.48832 Gbps
–Code: Scrambled NRZ
–Fiber: 1550-nm single-mode
–Maximum chromatic dispersion allowance: Compliant with SR-1 specification for OC-192. In the case of 10 GE, allowance is up to 10 km of SMF fiber of dispersion.
–Loopback modes: Terminal and facility
–Connectors: LC
–Compliance: Telcordia GR-253-CORE, ITU-T G.707, ITU-T G.957
•Transmitter (client side): Depends on the Small Form-factor Pluggable (SFP) that is used.
•Receiver (client side): Depends on the SFP that is used.
•Environmental
–Operating temperature: -5 to +55 degrees Celsius (+23 to +113 degrees Fahrenheit)
–Operating humidity: 5 to 95 percent, noncondensing
–Power consumption: 50.00 W, 1.04 A at -48 V, 170.7 BTU/hr
•Dimensions
–Height: 12.650 in. (321.3 mm)
–Width: 0.716 in. (18.2 mm)
–Depth: 9.000 in. (228.6 mm)
–Depth with backplane connector: 9.250 in. (235 mm)
–Weight not including clam shell: 3.1 lb (1.3 kg)
B.5.3 TXP_MR_2.5G and TXPP_MR_2.5G Card Specifications
The TXP_MR_2.5G and TXPP_MR_2.5G cards have the following specifications:
•Line (trunk side)
–Bit rate:
2.488 Gbps for OC-48/STM-16
2.66 Gbps with ITU-T G.709 Digital Wrapper/FEC
–Code: Scrambled NRZ
–Fiber: 1550-nm single-mode
–Maximum chromatic dispersion allowance: 5400 ps/nm
–Loopback modes: Terminal and facility
Caution You must use a 20-dB fiber attenuator (15 to 25 dB) when working with the TXP_MR_2.5G and TXPP_MR_2.5G cards in a loopback on the trunk port. Do not use direct fiber loopbacks with the TXP_MR_2.5G and TXPP_MR_2.5G cards. Using direct fiber loopbacks causes irreparable damage to the TXP_MR_2.5G and TXPP_MR_2.5G cards.
–Connectors: LC
–Compliance: Telcordia GR-253-CORE, ITU-T G.707, ITU-T G.957
•Transmitter (trunk side)
–Maximum transmitter output power: +1 dBm
–Minimum transmitter output power: -4.5 dBm
–Transmitter: Direct modulated laser
–Wavelength stability (drift): +/- 25 picometers (pm)
Note An optical device on the card keeps the laser wavelength locked as closely as possible to the ITU nominal value. The allowed drift is +/- 25 pm.
•Currently available wavelengths of TXP_MR_2.5G and TXPP_MR_2.5G (eight card versions):
ITU grid blue band: 1530.334 to 1544.526 nm (four card versions covering four wavelengths each)
ITU grid red band: 1546.119 to 1560.606 nm (four card versions covering four wavelengths each)
•Receiver (trunk side)
Table B-19 TXP_MR_2.5G/TXPP_MR_2.5G Receiver Trunk Side Specifications
OSNR1 FEC Type Pre-FEC BER Post-FEC BER Input Power Sensitivity Chromatic Dispersion Tolerance22 dB
Off - 2R
<10 exp - 12
N/A
- 9 to - 24 dBm
—
22 dB
Off - 2R
<10 exp - 12
N/A
- 9 to - 21 dBm
+/- 3300ps/nm
21 dB
Off - 3R
<10 exp - 12
N/A
- 9 to - 30 dBm
—
22 dB
Off - 3R
<10 exp - 12
N/A
- 9 to - 30 dBm
+/- 1800ps/nm
23 dB
Off - 3R
<10 exp - 12
N/A
- 9 to - 30 dBm
+/- 5400ps/nm
12 dB
Standard- 3R
<10 exp - 5
<10 exp - 15
- 9 to - 25 dBm
—
12 dB
Standard- 3R
<10 exp - 5
<10 exp - 15
- 9 to - 24 dBm
+/- 1800ps/nm
12 dB
Standard- 3R
<10 exp - 5
<10 exp - 15
- 9 to - 23 dBm
+/- 5400ps/nm
21 dB
Standard- 3R
<10 exp - 5
<10 exp - 15
- 9 to - 31 dBm
—
1 Optical Signal-to-Noise ratio (OSNR) defined with 0.1 nm Resolution Bandwidth (RBW)
–Receiver: APD
–Link loss budget: 24 dB minimum, with no dispersion or 22 dB optical path loss at
BER = 1 * 10 exp - 12 including dispersion–Receiver input wavelength range: 1290 to 1605 nm
•Line (client side)
–Bit rate: 8 Mbps to 2.488 Gbps
–Code: Scrambled NRZ
–Fiber: 1310-nm single-mode
–Maximum chromatic dispersion allowance: 1600 ps/nm
–Loopback modes: Terminal and facility
–Connectors: LC
–Compliance: Telcordia GR-253-CORE, ITU-T G.707, ITU-T G.957
•Transmitter (client side)
–Maximum transmitter output power: -1 dBm
–Minimum transmitter output power: -6 dBm
–Center wavelength: 1290 to 1330 nm
–Nominal wavelength: 1310 nm
–Transmitter: DFB laser
•Receiver (client side)
–Maximum receiver level: -1 dBm at BER 1 * 10 exp - 12
–Minimum receiver level: -14 dBm at BER 1 * 10 exp - 12
–Receiver: APD
–Link loss budget: 8 dB minimum, at BER = 1 * 10 exp - 12
–Receiver input wavelength range: 1290 to 1605 nm
•Environmental
–Operating temperature: -5 to +45 degrees Celsius (+23 to +113 degrees Fahrenheit)
–Operating humidity: 5 to 95 percent, noncondensing
–Power consumption: 35.00 W, 0.73 A at -48 V, 119.5 BTU/hr
•Dimensions
–Height: 12.650 in. (321.3 mm)
–Width: 0.716 in. (18.2 mm)
–Depth: 9.000 in. (228.6 mm)
–Depth with backplane connector: 9.250 in. (235 mm)
–Weight not including clam shell: 3.1 lb (1.3 kg)
B.5.4 MXP_MR_2.5G and MXPP_MR_2.5G Card Specifications
The MXP_MR_2.5G and MXPP_MR_2.5G cards have the following specifications:
•Payload configuration
–FC1G—Fiber Channel 1.06 Gbps
–FC2G—Fiber Channel 2.125 Gbps
–FICON1G—Fiber CON 1.06 Gbps (IBM signal)
–FICON2G—Fiber CON 2.125 Gbps (IBM signal)
–ONE_GE—One Gigabit Ethernet 1.125 Gbps
–Mixed configurations up to maximum line rate (for example, if you have a port configured for 2G FC, you cannot use another port at the same time)
•Client ports: 8x SFP
•Performance monitoring (PM) for all interfaces
•Buffer-to-buffer credit management for distance extension
•Line (trunk side)
–Bit rate: 2.488 Gbps for OC-48/STM-16
–Code: Scrambled NRZ
–Fiber: 1550-nm single-mode
–Maximum chromatic dispersion allowance: 6000 ps/nm
–Loopback modes: Terminal and facility
Caution You must use a 20-dB fiber attenuator (15 to 25 dB) when working with the MXP_MR_2.5G and MXPP_MR_2.5G cards in a loopback on the trunk port. Do not use direct fiber loopbacks with the MXP_MR_2.5G and MXPP_MR_2.5G cards. Using direct fiber loopbacks causes irreparable damage to the MXP_MR_2.5G and MXPP_MR_2.5G cards.
–Connectors: LC
–Compliance: Telcordia GR-253-CORE, Telcordia GR-2918-CORE, Issue 2, ITU-T G.957, and ITU-T 100-GHz grid standard G.692
•Transmitter (trunk side)
–Transmit power: +3 +/- 1 dBm with MXP_MR_2.5G card, and +/- 1 dBm with MXPP_MR_2.5G card
–50-GHz DWDM migration ready (the wavelength deviation is less than +/- 0.040 nm through wavelocker deployment)
–Four-channel wavelength tunability at 100-GHz spacing
–Transmitter maximum return reflectance: -27 dB
–Chromatic dispersion allowance: 5400 ps/nm, giving an optical power penalty < 2.0 dB
–Minimum side mode suppression ratio: 30 dB
–Transmitter is a direct modulated laser
–Wavelength stability (drift): +/- 25 picometers (pm)
Note An optical device on the card keeps the laser wavelength locked as closely as possible to the ITU nominal value. The allowed drift is +/- 25 pm.
•Currently available wavelengths of the TXP_MR_2.5G and TXPP_MR_2.5G cards (eight card versions):
ITU grid blue band: 1530.334 to 1544.526 nm (four card versions, four wavelengths each)
ITU grid red band: 1546.119 to 1560.606 nm (four card versions, four wavelengths each)
•Receiver (trunk side)
Table B-20 MXP_MR_2.5G/MXPP_MR_2.5G Receiver Trunk Side Specifications
OSNR1 FEC Type Pre-FEC BER Post-FEC BER Input Power Sensitivity Chromatic Dispersion Tolerance17 dB
N/A
<10 exp - 12
N/A
- 9 to - 23 dBm
—
17 dB
N/A
<10 exp - 12
N/A
- 9 to - 22 dBm
+/- 1800 ps/nm
17 dB
N/A
<10 exp - 12
N/A
- 9 to - 21 dBm
+/- 5400 ps/nm
18 dB
N/A
<10 exp - 12
N/A
- 9 to - 23 dBm
+/- 1800 ps/nm
19 dB
N/A
<10 exp - 12
N/A
- 9 to - 23 dBm
+/- 5400 ps/nm
21 dB
N/A
<10 exp - 12
N/A
- 9 to - 30 dBm
—
21 dB
N/A
<10 exp - 12
N/A
- 9 to - 29 dBm
+/- 1800 ps/nm
21 dB
N/A
<10 exp - 12
N/A
- 9 to - 28 dBm
+/- 5400 ps/nm
22 dB
N/A
<10 exp - 12
N/A
- 9 to - 30 dBm
+/- 1800 ps/nm
23 dB
N/A
<10 exp - 12
N/A
- 9 to - 30 dBm
+/- 5400 ps/nm
1 Optical Signal-to-Noise ratio (OSNR) defined with 0.1 nm Resolution Bandwidth (RBW)
–Receiver sensitivity -28 dBm, BER 1 * 10 exp - 12
–Receiver overload is equal to or exceeds -8 dBm
–Receiver maximum reflectance of -27 dB
•Line (client side)
–Bit rate: 1.06 Gbps to 2.125 Gbps per client
–Code: Scrambled NRZ
–Fiber: 1310-nm single-mode or 850-nm multimode
–Maximum chromatic dispersion allowance: 1600 ps/nm
–Loopback modes: Terminal and facility
–Connectors: LC
–Compliance: Telcordia GR-253-CORE, ITU-T G.707, ITU-T G.957
•Transmitter (client side)
–Maximum transmitter output power: -1 dBm
–Minimum transmitter output power: -6 dBm
–Center wavelength: 1290 to 1330 nm
–Nominal wavelength: 1310 nm
–Transmitter: DFB laser
•Receiver (client side)
–Maximum receiver level: -1 dBm at BER 1 * 10 exp - 12
–Minimum receiver level: -14 dBm at BER 1 * 10 exp - 12
–Receiver: APD
–Link loss budget: 8 dB minimum, at BER = 1 * 10 exp - 12
–Receiver input wavelength range: 1290 to 1605 nm
•Environmental
–Operating temperature: -5 to +40 degrees Celsius (+23 to +104 degrees Fahrenheit)
–Operating humidity: 5 to 85 percent, noncondensing
–Power consumption (maximum): 60 W, 1.25 A at -48 V, 204 BTU/hr
•Dimensions
–Height: 12.650 in. (321.3 mm)
–Width: 0.716 in. (18.2 mm)
–Depth: 9.000 in. (228.6 mm)
–Depth with backplane connector: 9.250 in. (235 mm)
–Weight not including clam shell: 2.25 lb (1.02 kg)
B.5.5 MXP_2.5G_10E Card Specifications
The MXP_2.5G_10E card has the following specifications:
•Line (trunk side)
–Bit rate: 10.70923 Gbps (in ITU-T G.709 Digital Wrapper/FEC mode)
–Code: Scrambled NRZ
–Fiber: 1550-nm single-mode
–Maximum chromatic dispersion allowance: +/- 1200 ps/nm (specified penalty)
–Loopback modes: Terminal and facility
Caution You must use a 20-dB fiber attenuator (15 to 25 dB) when working with the MXP_2.5G_10E card in a loopback on the trunk port. Do not use direct fiber loopbacks with the MXP_2.5G_10E card. Using direct fiber loopbacks causes irreparable damage to the MXP_2.5G_10E card.
–Connectors: LC
–Compliance: ITU-T G.707, ITU-T G.709, ITU-T G.957, and Telcordia GR-253-CORE
•Transmitter (trunk side)
–Maximum transmitter output power: +6 dBm
–Minimum transmitter output power: +3 dBm
–Transmitter: LN external modulator transmitter
–Wavelength stability (drift): +/- 25 picometers (pm)
Note An optical device on the card keeps the laser wavelength locked as closely as possible to the ITU nominal value. The allowed drift is +/- 25 pm.
•Currently available wavelengths and versions of MXP_2.5G_10E (eight card versions):
ITU grid blue band:
–1530.33 to 1533.07 nm (four channels)
–1534.25 to 1537.00 nm (four channels)
–1538.19 to 1540.95 nm (four channels)
–1542.14 to 1544.92 nm (four channels)
ITU grid red band:
–1546.12 to 1548.92 nm (four channels)
–1550.12 to 1552.93 nm (four channels)
–1554.13 to 1556.96 nm (four channels)
–1558.17 to 1561.01 nm (four channels)
•Receiver (trunk side)
Table B-21 MXP_2.5G_10E Receiver Trunk Side Specifications
OSNR1 FEC Type Pre-FEC BER Post-FEC BER Input Power Sensitivity2 Chromatic Dispersion Tolerance30 dB
Off
<10 exp - 12
N/A
- 8 to - 20 dBm
+/- 1200 ps/nm
26 dB
Off
<10 exp - 12
N/A
- 8 to - 20 dBm
+/- 1000 ps/nm
26 dB
Off
<10 exp - 12
N/A
- 8 to - 22 dBm
—
17 dB
Standard
<10 exp - 5
<10 exp - 15
- 8 to - 18 dBm
+/- 800 ps/nm
15 dB
Standard
<10 exp - 5
<10 exp - 15
- 8 to - 18 dBm
—
15 dB
Enhanced
<7 x 10 exp - 4
<10 exp - 15
- 8 to - 18 dBm
+/- 800 ps/nm
14 dB
Enhanced
<7 x 10 exp - 4
<10 exp - 15
- 8 to - 18 dBm
—
1 Optical Signal-to-Noise ratio (OSNR) defined with 0.1 nm Resolution Bandwidth (RBW)
2 Receiver filter bandwidth greater than or equal to 180 pm (at - 3 dBm)
–Receiver: APD
–Link loss budget: 24 dB minimum, with no dispersion or 22 dB optical path loss at
BER = 1 * 10 exp - 12 including dispersion–Receiver input wavelength range: 1290 to 1605 nm
•Line (client side)
–Bit rate: 2.5 Gbps per port (OC-48/STM-16)
–Code: Scrambled NRZ
–Fiber: 1310-nm single-mode
–Maximum chromatic dispersion allowance: 12 ps/nm (SR SFP version)
–Loopback modes: Terminal and facility
–Connectors: LC (optical)
–Compliance: Telcordia GR-253-CORE, ITU-T G.707, ITU-T G.957
•Transmitter (client side): Depends on the SFP that is used.
•Receiver (client side): Depends on the SFP that is used.
•Environmental
–Operating temperature: -5 to +55 degrees Celsius (+23 to +113 degrees Fahrenheit)
–Operating humidity: 5 to 95 percent, noncondensing
–Power consumption: 50.00 W (maximum), 1.11 A at -48 V, 136.6 BTU/hr
•Dimensions
–Height: 12.650 in. (321.3 mm)
–Width: 0.716 in. (18.2 mm)
–Depth: 9.000 in. (228.6 mm)
–Depth with backplane connector: 9.250 in. (235 mm)
–Weight not including clam shell: 3.1 lb (1.3 kg)
B.5.6 TXP_MR_10E Card Specifications
The TXP_MR_10E card has the following specifications:
•Line (trunk side)
–Bit rate: OC-192/STM-64 (9.95328 Gbps), OTU2 (10.70923 Gbps), 10GE (10.3125 Gbps), 10GE into OTU2 (non-standard 11.0957 Gbps), 10G FC (10.51875 Gbps), or 10G FC into OTU2 (non-standard 11.31764 Gbps)
–Code: Scrambled NRZ
–Fiber: 1550-nm single-mode
–Maximum chromatic dispersion allowance: +/- 1200 ps/nm (specified penalty)
–Loopback modes: Terminal and facility
Caution You must use a 15-dB fiber attenuator (10 to 20 dB) when working with the TXP_MR_10E card in a loopback on the trunk port. Do not use direct fiber loopbacks with the TXP_MR_10E card. Using direct fiber loopbacks causes irreparable damage to the TXP_MR_10E card.
–Connectors: LC
–Compliance: Telcordia GR-253-CORE, ITU-T G.707, ITU-T G.957, and ITU-T G.709
•Transmitter (trunk side)
–Maximum transmitter output power: +6 dBm
–Minimum transmitter output power: +3 dBm for C-band and +2 dBm for L-band
–Transmitter: LN external modulator transmitter
–Wavelength stability (drift): +/- 25 picometers (pm)
Note An optical device on the card keeps the laser wavelength locked as closely as possible to the ITU nominal value. The allowed drift is +/- 25 pm.
•Currently available wavelengths and versions of TXP_MR_10E:
C-band frequency plan (eight card versions, each with four tunable channels on the ITU 100-GHz grid):
–1530.33 to 1533.07 nm (four channels)
–1534.25 to 1537.00 nm (four channels)
–1538.19 to 1540.95 nm (four channels)
–1542.14 to 1544.92 nm (four channels)
–1546.12 to 1548.92 nm (four channels)
–1550.12 to 1552.93 nm (four channels)
–1554.13 to 1556.96 nm (four channels)
–1558.17 to 1561.01 nm (four channels)
L-band frequency plan (five card versions, each with eight tunable channels on the ITU 50-GHz grid):
–1577.44 to 1580.35 nm (eight channels)
–1580.77 to 1583.69 nm (eight channels)
–1584.11 to 1587.04 nm (eight channels)
–1587.46 to 1590.41 nm (eight channels)
–1590.83 to 1593.79 nm (eight channels)
•Receiver (trunk side)
Table B-22 TXP_MR_10E Receiver Trunk Side Specifications
OSNR1 FEC Type Pre-FEC BER Post-FEC BER Input Power Sensitivity2 Chromatic Dispersion Tolerance30 dB
Off
<10 exp - 12
N/A
- 8 to - 20 dBm
+/- 1200 ps/nm
26 dB
Off
<10 exp - 12
N/A
- 8 to - 20 dBm
+ - 1000 ps/nm
26 dB
Off
<10 exp - 12
N/A
- 8 to - 22 dBm
—
17 dB
Standard
<10 exp - 5
<10 exp - 15
- 8 to - 18 dBm
+/- 800 ps/nm
15 dB
Standard
<10 exp - 5
<10 exp - 15
- 8 to - 18 dBm
—
15 dB
Enhanced
<7 x 10 exp - 4
<10 exp - 15
- 8 to - 18 dBm
+/- 800 ps/nm
14 dB
Enhanced
<7 x 10 exp - 4
<10 exp - 15
- 8 to - 18 dBm
—
1 Optical Signal-to-Noise ratio (OSNR) defined with 0.1 nm Resolution Bandwidth (RBW)
2 Receiver filter bandwidth greater than or equal to 180 pm (at - 3 dBm)
–Receiver: APD
–Link loss budget: 24 dB minimum, with no dispersion or 22 dB optical path loss at
BER = 1 * 10 exp - 12 including dispersion–Receiver input wavelength range: 1290 to 1605 nm
•Line (client side):
–10-Gigabit Small Form-factor Pluggable (XFP)-based SR
–Bit rate: 10GE (10.3125 Gbps), 10G FC (10.51875 Gbps), or STM-64/OC-192
–Code: Scrambled NRZ
–Fiber: 1310-nm single-mode
–Maximum chromatic dispersion allowance: 6.6 ps/nm
–Loopback modes: Terminal and facility
–Connectors: LC
–Compliance: Telcordia GR-253-CORE, ITU-T G.707, ITU-T G.957, ITU-T G.691
•Transmitter (client side)
–Maximum transmitter output power: -1 dBm
–Minimum transmitter output power: -6 dBm
–Center wavelength: 1290 to 1330 nm
–Nominal wavelength: 1310 nm
–Transmitter: DFB laser
•Receiver (client side)
–Maximum receiver level: -1 dBm at BER 1 * 10 exp - 12
–Minimum receiver level: -14 dBm at BER 1 * 10 exp - 12
–Receiver: APD
–Link loss budget: 8 dB minimum, at BER = 1 * 10 exp - 12
–Receiver input wavelength range: 1290 to 1605 nm
•Environmental
–Operating temperature: -5 to +55 degrees Celsius (+23 to +113 degrees Fahrenheit)
–Operating humidity: 5 to 95 percent, noncondensing
–Power consumption: 50.00 W (maximum), 1.11 A at -48 V, 136.6 BTU/hr
•Dimensions
–Height: 12.650 in. (321.3 mm)
–Width: 0.716 in. (18.2 mm)
–Depth: 9.000 in. (228.6 mm)
–Depth with backplane connector: 9.250 in. (235 mm)
–Weight not including clam shell: 3.1 lb (1.3 kg)
B.6 SFP Specifications
Table B-23 lists the specifications for available SFPs.
Table B-23 SFP Specifications
SFP Product ID Interface Transmitter Output Power Min/Max (dBm) Receiver Input Power Min/Max (dBm)15454-SFP3-1-IR=
OC-3
-15 to -8
-23 to -8
15454E-SFP-L.1.1=
STM-1
-15 to -8
-34 to -10
15454-SFP12-4-IR=
OC-12, D1 Video
-15 to -8
-28 to -7
15454E-SFP-L.4.1=
STM-4, D1 Video
-15 to -8
-28 to -8
15454-SFP-OC48-IR=
OC-48, DV6000 (C-Cor)
-5 to +0
-18 to +0
ONS-SE-2G-S1=
OC-48, STM-16
-10 to -3
-18 to -3
15454E-SFP-L.16.1=
STM-16, DV6000 (C-Cor)
-5 to +0
-18 to 0
15454-SFP-200/
15454E-SFP-200ESCON1
-8 to -4
-28 to -3
15454-SFP-GEFC-SX=/
15454E-SFP-GEFC-S=Fibre Channel (1 and 2 Gbps), FICON2 , GE
-10 to -3.5
-17 to 0 (1FC and 1GE)
-15 to 0 (2FC)
15454-SFP-GE+-LX=/
15454E-SFP-GE+-LX=Fibre Channel
(1 and 2 Gbps), FICON, GE, HDTV3-9.5 to -3.0
-20 to -3 (1FC, 1GE, and 2FC)
ONS-SE-2G-L2
OC-48, STM-16
-2 to 3
-28 to -9
1 ESCON = Enterprise System Connection
2 FICON = fiber connectivity
3 HDTV = high-definition television
SFP Port Cabling Specifications
Table B-24 provides cabling specifications for the single-mode fiber (SMF) SFPs and Table B-25 provides cabling specifications for multimode fiber (MMF) SFPs that you install into Ethernet cards. The ports of the listed SFPs have LC-type connectors.
Table B-24 Single-Mode Fiber SFP Port Cabling Specifications
SFP Product ID Wavelength1 Fiber Type Cable Distance15454-SFP3-1-IR=
Intermediate Reach1310 nm
9 micron SMF
15 km (9.3 miles)
15454E-SFP-L.1.1=
Short Haul1310 nm
9 micron SMF
15 km (9.3 miles)
15454-SFP12-4-IR=
Intermediate Reach1310 nm
9 micron SMF
15 km (9.3 miles)
15454E-SFP-L.4.1=
Short Haul1310 nm
9 micron SMF
15 km (9.3 miles)
15454-SFP-OC48-IR=
Intermediate Reach1310 nm
9 micron SMF
15 km (9.3 miles)
ONS-SE-2G-S1=
Short Reach1310 nm
9 micron SMF
2 km (1.2 miles)
15454E-SFP-L.16.1=
Short Haul1310 nm
9 micron SMF
15 km (9.3 miles)
15454-SFP-GE+-LX=/
15454E-SFP-GE+-LX=
Long Reach1310 nm
9 micron SMF
10 km (6.2 miles) for FC 1G, FC 2G, and GE
5 km (3.1 miles) for HDTV
1 Typical loss on a 1310 nm wavelength is 0.6 dB/km.
B.7 XFP Specifications
Table B-26 lists the specifications for available XFPs.
B.7.1 XFP Port Cabling Specifications
Table B-27 provides cabling specifications for the SMF XFPs. The ports of the listed XFPs have LC-type connectors.
Table B-27 Single-Mode Fiber XFP Port Cabling Specifications
XFP Product ID Wavelength1 Fiber Type Cable DistanceONS-XC-10G-S1
1310 nm
SMF
10 km (6.2 miles)
1 Typical loss on a 1310 nm wavelength is 0.6 dB/km.
Posted: Mon Dec 3 04:05:22 PST 2007
All contents are Copyright © 1992--2007 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.