Table Of Contents
TL1 Command Components
4.1 TL1 Default Values
4.1.1 BLSR
4.1.2 Cross Connections
4.1.3 Environment Alarms and Controls
4.1.4 Equipment
4.1.5 Performance
4.1.6 Ports
4.1.7 SONET Line Protection
4.1.8 STS and VT Paths
4.1.9 Synchronization
4.1.10 Testing
4.2 Modifier Support by Platform
4.3 Starting Positions for an STS-Mc SPE
4.4 Conditions
4.5 Access Identifiers
4.5.1 ALL
4.5.2 AidUnionId
4.5.3 AidUnionId1
4.5.4 BAND
4.5.5 BITS
4.5.6 BLSR
4.5.7 CHANNEL
4.5.8 COM
4.5.9 CrossConnectId
4.5.10 CrossConnectId1
4.5.11 DS1
4.5.12 ENV
4.5.13 EQPT
4.5.14 FACILITY
4.5.15 IPADDR
4.5.16 LINE
4.5.17 LNKTERM
4.5.18 OPM
4.5.19 OSC
4.5.20 PRSLOT
4.5.21 RFILE
4.5.22 STS
4.5.23 SYN
4.5.24 SYN_SRC
4.5.25 SYNC_REF
4.5.26 SYNCSW
4.5.27 UDC
4.5.28 VT
4.5.29 WDMANS
4.5.30 WLEN
4.6 Parameter Types
4.6.1 ATAG Description
4.6.2 CTAG Description
4.6.3 TID Description
4.6.4 Parameter Notes
TL1 Command Components
Note The terms "Unidirectional Path Switched Ring" and "UPSR" may appear in Cisco literature. These terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring configuration. Rather, these terms, as well as "Path Protected Mesh Network" and "PPMN," refer generally to Cisco's path protection feature, which may be used in any topological network configuration. Cisco does not recommend using its path protection feature in any particular topological network configuration.
This chapter describes the components of TL1 commands and autonomous messages for the
Cisco ONS 15454, 15327, 15600, 15310-CL, Release 5.0, including:
•TL1 default values
•Modifier support by platform
•Starting positions for an STS-Mc SPE
•Access identifiers (AIDs)
•Parameter Notes
4.1 TL1 Default Values
4.1.1 BLSR
Table 4-1 BLSR Default Values
BLSR
|
Default
|
RVRTV
|
Y
|
RVTM
|
5.0 minutes
|
SRVRTV
|
Y
|
SRVTM
|
5.0 minutes
|
4.1.2 Cross Connections
Table 4-2 Cross Connections Default Values
Cross Connections
|
Default
|
CCT
|
2WAY for both STSp and VT1 cross-connections
|
4.1.3 Environment Alarms and Controls
Table 4-3 Environment Alarms and Controls Default Values
Environment Alarms and Controls
|
Default
|
OPR-EXT-CONT
|
CONTTYPE is set as one provisioned in the respective AID, there is not default for it. It is only used as a filter if entered. DUR is always taken as CONT.
|
RTRV-ATTR-CONT
|
There is no default for CONTTYPE. It is only used as a filter if entered.
|
RTRV-ATTR-ENV
|
There is no default for both NTFCNCDE and ALMTYPE, which are only used as filters if entered.
|
RTRV-EXT-CONT
|
CONTTYPE defaults to the conttype associated with the AID.
|
SET-ATTR-ENV
|
NTFCNCDE defaults to NR. ALMTYPE defaults to NULL. ALMMSG defaults to \"Env Alarm Input 1\".
|
4.1.4 Equipment
Table 4-4 Equipment Default Values
Equipment
|
Default
|
ALW-SWTOPROTN-EQPT, INH-SWTOPROTN-EQPT and ALW-SWTOWKG-EQPT, ING-SWTOWKG-EQPT
|
DIRN defaults to BTH
|
ENT-EQPT
|
PROTID, PRTYPE, RVRTV and RVTM defaults to NULL
|
SW-DX-EQPT
|
MODE defaults to NORM
|
SW-TOPROTN-EQPT and SW-TOWKG-EQPT
|
MODE defaults to NORM DIRN defaults to BTH
|
4.1.5 Performance
Table 4-5 Performance Default Values
Performance
|
Default
|
INIT-REG-<MOD2>
|
LOCN defaults to NEND (near end)
|
RTRV-PM-<MOD2>
|
LOCN defaults to NEND TMPER defaults to 15 minutes
|
RTRV-TH-<MOD2>
|
MONTYPE defaults to CVL for OCN, EC1, and DSN MONTYPE defaults to ESP for STSp MONTYPE defaults to UASV for VT1 MONTYPE defaults to AISSP for the DS1 layer of the DS3XM card LOCN defaults to NEND TMPER defaults to 15 minutes
|
SET-PMMODE-<STS_PATH>
|
PMSTATE defaults to ON
|
SET-TH-<MOD2>
|
LOCN defaults to NEND TMPER defaults to 15 minutes
|
4.1.6 Ports
Table 4-6 Ports Default Values
Ports
|
Default
|
OCN Line
|
DCC defaults to N TMGREF defaults to N SYNCMSG defaults to Y SENDDUS defaults to N PJMON defaults to 0 SFBER defaults to 1E-4 SDBER defaults to 1E-7 MODE defaults to SONET PST defaults to OOS
|
EC1 Line
|
PJMON defaults to 0 (zero) LBO defaults to 0-225 RXEQUAL is Y PST defaults to defaults to OOS
|
T1 Line (DS1/DS1N)
|
LINECDE defaults to AMI FMT defaults to D4 LBO defaults to 0-133 PST defaults to OOS
|
T3 Line (DS3, DS3E, DS3NE, DS3XM)
|
DS3/T3 LINECDE defaults to 0-225 DS3 PST defaults to OOS DS3E/DS3NE FMT defaults to UNFRAMED DS3E/DS3NE LINECDE defaults to B3ZS DS3E/DS3NE LBO defaults to 0-225 DS3 of DS3XM PST defaults to OOS
|
4.1.7 SONET Line Protection
Table 4-7 SONET Line Protection Default Values
SONET Line Protection
|
Default
|
EX-SW-<OCN>
|
ST (switch type) is optional and for BLSR protection switch only ST defaults to BLSR RING switch type
|
OCN Line Protection
|
PROTID defaults to the protecting port of the protection group (SLOT-#(OCN)PORT-#). It is a string that can have a maximum length of 32 characters RVRTV defaults to N (non-revertive mode) RVTM defaults to 5.0 minutes PSDIRN defaults to UNI
|
OPR-PROTNSW-<OCN>
|
ST (switch type) is optional and for BLSR protection switch only ST defaults to BLSR RING switch type
|
4.1.8 STS and VT Paths
Table 4-8 STS and VT Paths Default Values
STS and VT Paths
|
Default
|
STS Path
|
SFBER, SDBER, RVRTV, and RVTM apply to path protection STS paths only SFBER defaults to 1E-4 SDBER defaults to 1E-6 RVRTV defaults to N RVTM defaults to empty because RVRTV is N when path protection STSp is created
J1 is implemented on DS1, DS1N, DS3, DS3E, DS3NE, DS3XM, EC1, OC3, OC48AS AND OC192 cards TRCMODE defaults to the OFF mode
EXPTRC defaults to a copy of the provisioned string or NULL when TRCMODE is OFF mode EXPTRC defaults to the user entered string when the TRCMODE is MANUAL mode EXPTRC defaults to a copy of the acquired received string or NULL if the string has not been acquired when the TRCMODE is AUTO mode
INCTRC defaults to the incoming string (NULL) when the TRCMODE is under OFF mode INCTRC defaults to a copy of the received string or NULL if the string has not been received when the TRCMODE is under MANUAL or AUTO mode
|
VT Path
|
RVRTV, RVTM apply to path protection VT paths only RVRTV defaults to N RVTM defaults to empty because RVRTV is N when path protection VT1 is created
|
4.1.9 Synchronization
Table 4-9 Synchronization Default Values
Synchronization
|
Default
|
BITS
|
LINECDE defaults to B8ZS FMT defaults to ESF SYNCMSG defaults to Y PST defaults to OOS
|
NE-SYNCN
|
TMMDE defaults to EXTERNAL SSMGEN defaults to GEN1 QRES defaults to SAME-AS-DUS RVRTV defaults to Y RVTM defaults to 5.0 minutes
|
SYNCN
|
PRI/SEC QREF defaults to PRS PRI STATUS defaults to ACT SEC STATUS defaults to STBY THIRD QREF defaults to ST3 STATUS defaults to STBY
|
4.1.10 Testing
Table 4-10 Testing Default Values
Testing
|
Default
|
OPR-LPBK
|
LPBKTYPE defaults to FACILITY
|
RLS-LPBK
|
LPBKTYPE defaults to current existing loopback type
|
4.2 Modifier Support by Platform
Table 4-11 details the TL1 modifiers supported on the ONS SONET 15454, 15327, 15310-CL, and 15600 for commands that have carets (< >) in part of their input format; for example, RTRV-<OCN_TYPE>. A "Yes" in the platform column indicates that a particular modifier is supported in that platform. A "No" in the platform column indicates that a particular modifier is not supported in that platform. A "—" indicates that a particular modifier is not applicable to that platform.
Table 4-11 Modifier Support
Modifier
|
ONS 15454
|
ONS 15327
|
ONS 15310-CL
|
ONS 15600
|
DS1
|
Yes
|
—
|
—
|
—
|
EC1
|
Yes
|
—
|
Yes
|
—
|
T1
|
Yes
|
Yes
|
Yes
|
—
|
T3
|
Yes
|
Yes
|
Yes
|
—
|
VT1
|
Yes
|
Yes
|
Yes
|
—
|
STS1
|
Yes
|
Yes
|
Yes
|
Yes
|
STS3C
|
Yes
|
Yes
|
Yes
|
Yes
|
STS6C
|
Yes
|
Yes
|
Yes
|
No
|
STS9C
|
Yes
|
Yes
|
Yes
|
No
|
STS12C
|
Yes
|
Yes
|
Yes
|
Yes
|
STS24C
|
Yes
|
Yes
|
No
|
No
|
STS48C
|
Yes
|
Yes
|
No
|
Yes
|
STS192C
|
Yes
|
No
|
No
|
Yes
|
OC3
|
Yes
|
Yes
|
Yes
|
—
|
OC12
|
Yes
|
Yes
|
Yes
|
—
|
OC48
|
Yes
|
Yes
|
No
|
Yes
|
OC192
|
Yes
|
No
|
No
|
Yes
|
G1000
|
Yes
|
Yes
|
No
|
—
|
GIGE
|
Yes
|
No
|
No
|
—
|
FSTE
|
Yes
|
No
|
Yes
|
—
|
POS
|
Yes
|
No
|
Yes
|
—
|
E100
|
Yes
|
Yes
|
No
|
—
|
E1000
|
Yes
|
Yes
|
No
|
—
|
CLNT
|
Yes
|
No
|
No
|
—
|
OCH
|
Yes
|
No
|
No
|
—
|
OMS
|
No
|
—
|
—
|
—
|
OTS
|
No
|
—
|
—
|
—
|
4.3 Starting Positions for an STS-Mc SPE
Table 4-12, Table 4-13, and Table 4-14 list possible starting positions for the ONS 15454, ONS 15327, ONS 15310-CL and ONS 15600 STS-Mc SPE. In each of the tables a "Y" indicates "Yes, this position is supported" and an "N" indicates, "No, this position is not supported". More information about the generic NE support requirement can be found in GR-253-CORE: Synchronous Optical Network (SONET) Transport Systems: Common Generic Criteria.
Table 4-12 Starting Positions for an STS-Mc SPE in an OC-12 Signal
STS-1 Number
|
STS-3c SPE
|
STS-6c SPE
|
STS-9c SPE
|
STS-12c SPE
|
1
|
Y
|
Y
|
Y
|
Y
|
4
|
Y
|
Y
|
Y
|
N
|
7
|
Y
|
Y
|
N
|
N
|
10
|
Y
|
N
|
Y
|
N
|
Table 4-13 Starting Positions for an STS-Mc SPE in an OC-48 Signal
STS-1 Number
|
STS-3c SPE
|
STS-6c SPE
|
STS-9c SPE
|
STS-12c SPE
|
STS-24c SPE
|
STS-48c SPE
|
1
|
Y
|
Y
|
Y
|
Y
|
Y
|
Y
|
4
|
Y
|
Y
|
Y
|
N
|
Y
|
N
|
7
|
Y
|
Y
|
N
|
N
|
Y
|
N
|
10
|
Y
|
N
|
Y
|
N
|
Y
|
N
|
13
|
Y
|
Y
|
Y
|
Y
|
Y
|
N
|
16
|
Y
|
Y
|
Y
|
N
|
Y
|
N
|
19
|
Y
|
Y
|
Y
|
N
|
Y
|
N
|
22
|
Y
|
N
|
N
|
N
|
Y
|
N
|
25
|
Y
|
Y
|
Y
|
Y
|
Y
|
N
|
28
|
Y
|
Y
|
Y
|
N
|
N
|
N
|
31
|
Y
|
Y
|
N
|
N
|
N
|
N
|
34
|
Y
|
N
|
N
|
N
|
N
|
N
|
37
|
Y
|
Y
|
Y
|
Y
|
N
|
N
|
40
|
Y
|
Y
|
Y
|
N
|
N
|
N
|
43
|
Y
|
Y
|
N
|
N
|
N
|
N
|
46
|
Y
|
N
|
Y
|
N
|
N
|
N
|
Table 4-14 Starting positions for an STS-Mc SPE in an OC-192 Signal
STS-1 Number
|
STS-3c SPE
|
STS-6c SPE
|
STS-9c SPE
|
STS-12c SPE
|
STS-24c SPE
|
STS-48c SPE
|
STS-192c SPE
|
1
|
Y
|
Y
|
Y
|
Y
|
Y
|
Y
|
Y
|
4
|
Y
|
Y
|
Y
|
N
|
N
|
N
|
N
|
7
|
Y
|
Y
|
N
|
N
|
N
|
N
|
N
|
10
|
Y
|
N
|
Y
|
N
|
N
|
N
|
N
|
13
|
Y
|
Y
|
Y
|
Y
|
N
|
N
|
N
|
16
|
Y
|
Y
|
Y
|
N
|
N
|
N
|
N
|
19
|
Y
|
Y
|
Y
|
N
|
N
|
N
|
N
|
22
|
Y
|
N
|
N
|
N
|
N
|
N
|
N
|
25
|
Y
|
Y
|
Y
|
Y
|
N
|
N
|
N
|
28
|
Y
|
Y
|
Y
|
N
|
N
|
N
|
N
|
31
|
Y
|
Y
|
N
|
N
|
N
|
N
|
N
|
34
|
Y
|
N
|
N
|
N
|
N
|
N
|
N
|
37
|
Y
|
Y
|
Y
|
Y
|
N
|
N
|
N
|
40
|
Y
|
Y
|
Y
|
N
|
N
|
N
|
N
|
43
|
Y
|
Y
|
N
|
N
|
N
|
N
|
N
|
46
|
Y
|
N
|
Y
|
N
|
N
|
N
|
N
|
49
|
Y
|
Y
|
Y
|
Y
|
Y
|
Y
|
N
|
52
|
Y
|
Y
|
Y
|
N
|
N
|
N
|
N
|
55
|
Y
|
Y
|
Y
|
N
|
N
|
N
|
N
|
58
|
Y
|
N
|
N
|
N
|
N
|
N
|
N
|
61
|
Y
|
Y
|
Y
|
Y
|
N
|
N
|
N
|
64
|
Y
|
Y
|
Y
|
N
|
N
|
N
|
N
|
67
|
Y
|
Y
|
N
|
N
|
N
|
N
|
N
|
70
|
Y
|
N
|
N
|
N
|
N
|
N
|
N
|
73
|
Y
|
Y
|
Y
|
Y
|
N
|
N
|
N
|
76
|
Y
|
Y
|
Y
|
N
|
N
|
N
|
N
|
79
|
Y
|
Y
|
N
|
N
|
N
|
N
|
N
|
82
|
Y
|
N
|
Y
|
N
|
N
|
N
|
N
|
85
|
Y
|
Y
|
Y
|
Y
|
N
|
N
|
N
|
88
|
Y
|
Y
|
Y
|
N
|
N
|
N
|
N
|
91
|
Y
|
Y
|
Y
|
N
|
N
|
N
|
N
|
94
|
Y
|
N
|
N
|
N
|
N
|
N
|
N
|
97
|
Y
|
Y
|
Y
|
Y
|
Y
|
Y
|
N
|
100
|
Y
|
Y
|
Y
|
N
|
N
|
N
|
N
|
103
|
Y
|
Y
|
N
|
N
|
N
|
N
|
N
|
106
|
Y
|
N
|
N
|
N
|
N
|
N
|
N
|
109
|
Y
|
Y
|
Y
|
Y
|
N
|
N
|
N
|
112
|
Y
|
Y
|
Y
|
N
|
N
|
N
|
N
|
115
|
Y
|
Y
|
N
|
N
|
N
|
N
|
N
|
118
|
Y
|
N
|
Y
|
N
|
N
|
N
|
N
|
121
|
Y
|
Y
|
Y
|
Y
|
N
|
N
|
N
|
124
|
Y
|
Y
|
Y
|
N
|
N
|
N
|
N
|
127
|
Y
|
Y
|
Y
|
N
|
N
|
N
|
N
|
130
|
Y
|
N
|
N
|
N
|
N
|
N
|
N
|
133
|
Y
|
Y
|
Y
|
Y
|
N
|
N
|
N
|
136
|
Y
|
Y
|
Y
|
N
|
N
|
N
|
N
|
139
|
Y
|
Y
|
N
|
N
|
N
|
N
|
N
|
142
|
Y
|
N
|
N
|
N
|
N
|
Y
|
N
|
145
|
Y
|
Y
|
Y
|
Y
|
Y
|
N
|
N
|
148
|
Y
|
Y
|
Y
|
N
|
N
|
N
|
N
|
151
|
Y
|
Y
|
N
|
N
|
N
|
N
|
N
|
154
|
Y
|
N
|
Y
|
N
|
N
|
N
|
N
|
157
|
Y
|
Y
|
Y
|
Y
|
N
|
N
|
N
|
160
|
Y
|
Y
|
Y
|
N
|
N
|
N
|
N
|
163
|
Y
|
Y
|
Y
|
N
|
N
|
N
|
N
|
166
|
Y
|
N
|
N
|
N
|
N
|
N
|
N
|
169
|
Y
|
Y
|
Y
|
Y
|
N
|
N
|
N
|
172
|
Y
|
Y
|
Y
|
N
|
N
|
N
|
N
|
175
|
Y
|
Y
|
N
|
N
|
N
|
N
|
N
|
178
|
Y
|
N
|
N
|
N
|
N
|
N
|
N
|
181
|
Y
|
Y
|
Y
|
Y
|
N
|
N
|
N
|
184
|
Y
|
Y
|
Y
|
N
|
N
|
N
|
N
|
187
|
Y
|
Y
|
N
|
N
|
N
|
N
|
N
|
190
|
Y
|
N
|
Y
|
N
|
N
|
N
|
N
|
4.4 Conditions
Conditions include any problem detected on an ONS 15454, 15327, 15310-CL, and 15600 shelf. They can include standing or transient, notifications. A snapshot of all current raised, standing conditions on the network, node, or card can be retrieved in the CTC Conditions window or using the RTRV-COND commands. (In addition, some but not all cleared conditions are also found in the History tab.)
Table 4-15 Conditions
Condition
|
Description
|
AIS
|
Alarm Indication Signal
|
AIS-L
|
Alarm Indication Signal - Line
|
AIS-P
|
Alarm Indication Signal - Path
|
AIS-V
|
Alarm Indication Signal - VT
|
ALS
|
Automatic Laser Shutdown
|
APC-DISABLED
|
Automatic Power Control Disabled
|
APC-FAIL
|
Automatic Power Control Failure
|
APSB
|
Byte Failure
|
APSC-IMP
|
Improper APS Code
|
APSCDFLTK
|
Default K Byte
|
APSCINCON
|
Inconsistent APS Code
|
APSCM
|
Protection Switching Channel Match Failure
|
APSCNMIS
|
Node Id Mismatch
|
APSIMP
|
APS Invalid Mode
|
APSMM
|
Automatic Protection Switch Mode Mismatch
|
AS-CMD
|
Alarms Suppressed By User Command
|
AS-MT
|
Alarms Suppressed For Maintenance
|
AU-LOF
|
LOF - Administration Unit - Loss of Multi Frame
|
AUD-LOG-LOSS
|
Audit Log 100 Percent Full - Oldest records will be lost
|
AUD-LOG-LOW
|
Audit Log 80 Percent Full
|
AUTOLSROFF
|
Automatic Laser Shutoff Due To High Temperature
|
AUTORESET
|
Automatic System Reset
|
AUTOSW-AIS
|
Automatic path protection Switch Caused By AIS
|
AUTOSW-LOP
|
Automatic path protection Switch Caused By LOP
|
AUTOSW-PDI
|
Automatic path protection Switch Caused By PDI
|
AUTOSW-SDBER
|
Automatic path protection Switch Caused By SDBER
|
AUTOSW-SFBER
|
Automatic path protection Switch Caused By SFBER
|
AUTOSW-UNEQ
|
Automatic path protection Switch Caused By UNEQ
|
BAT-FAIL
|
Battery Failure
|
BKUPMEMP
|
Primary Non-Volatile Backup Memory Failure
|
BLSROSYNC
|
BLSR Out Of Sync
|
CARLOSS
|
Carrier Loss On The LAN
|
CKTDOWN
|
Signaling Unable to setup circuit
|
CLDRESTART
|
Cold Restart
|
COMIOXC
|
IO Slot To XCON Communication Failure
|
COMM-FAIL
|
Plug-in Module Communication Failure
|
CONTBUS-A-18
|
TCC A To DCC A Processor Communication Failure
|
CONTBUS-B-18
|
TCC B To DCC B Processor Communication Failure
|
CONTBUS_A
|
Controller A To Shelf Slot Communication Failure
|
CONTBUS_B
|
Controller B To Shelf Slot Communication Failure
|
CTNEQPT-MISMATCH
|
Connection Equipment Mismatch
|
CTNEQPT-PBPROT
|
Interconnection Equipment Failure - Protect XC Payload Bus
|
CTNEQPT-PBWORK
|
Interconnection Equipment Failure - Working XC Payload Bus
|
DATAFLT
|
Software Fault - Data Integrity Fault
|
DBOSYNC
|
Standby Database Out of Sync
|
DS3-MISM
|
DS3 Frame Format Mismatch
|
DSP-COMM-FAIL
|
DSP Communication Failure
|
DSP-FAIL
|
DSP Failure
|
DUP-IPADDR
|
IP address already in use within the same DCC Area
|
DUP-NODENAME
|
Node name already in use within the same DCC Area
|
E-W-MISMATCH
|
Both Ends Of Fiber Provisioned As East Or Both As West
|
EHIBATVG
|
Extreme High Volt
|
ELWBATVG
|
Extreme Low Volt
|
EOC
|
SDCC Termination Failure
|
EOC-L
|
Line DCC Termination Failure
|
EQPT
|
Equipment Failure
|
EQPT-MISS
|
Replaceable Equipment/Unit is Missing
|
ERFI-P-CONN
|
Enhanced Remote Failure Indication - Path - Connectivity
|
ERFI-P-PAYLD
|
Enhanced Remote Failure Indication - Path - Payload
|
ERFI-P-SRVR
|
Enhanced Remote Failure Indication - Path - Server
|
ERROR-CONFIG
|
Error in Startup Config
|
ETH-LINKLOSS
|
Rear Panel Ethernet Link Removed
|
EXCCOL
|
Excess Collisions On The LAN
|
EXERCISE-RING-FAIL
|
Exercise Request on Ring Failed
|
EXERCISE-RING-REQ
|
Exercise Request on Ring
|
EXERCISE-SPAN-FAIL
|
Exercise Request on Span Failed
|
EXERCISE-SPAN-REQ
|
Exercise Request on Span
|
EXT
|
Failure Detected External To The NE
|
EXTRA-TRAF-PREEMPT
|
Extra Traffic Preempted
|
FAILTOSW
|
Failure To Switch To Protection
|
FAILTOSW-PATH
|
Failure To Switch To Protection - Path
|
FAILTOSWR
|
Failure To Switch To Protection - Ring
|
FAILTOSWS
|
Failure To Switch To Protection - Span
|
FAN
|
Fan Failure
|
FANDEGRADE
|
Partial Fan Failure
|
FE-AIS
|
Far End AIS
|
FE-DS1-MULTLOS
|
Far End Multiple DS1 LOS Detected On DS3
|
FE-DS1-NSA
|
Far End DS1 Equipment Failure - Non Service Affecting
|
FE-DS1-SA
|
Far End DS1 Equipment Failure - Service Affecting
|
FE-DS1-SNGLLOS
|
Far End Single DS1 LOS
|
FE-DS3-NSA
|
Far End DS3 Equipment Failure - Non Service Affecting
|
FE-DS3-SA
|
Far End DS3 Equipment Failure - Service Affecting
|
FE-EQPT-NSA
|
Far End Common Equipment Failure - Non Service Affecting
|
FE-EXERCISING-RING
|
Far End Exercising Ring
|
FE-EXERCISING-SPAN
|
Far End Exercising Span
|
FE-FRCDWKSWPR-RING
|
Far End Working Facility Forced To Switch To Protection - Ring
|
FE-FRCDWKSWPR-SPAN
|
Far End Working Facility Forced To Switch To Protection - Span
|
FE-IDLE
|
Far End IDLE
|
FE-LOCKOUTOFPR-SPAN
|
Far End Lockout Of Protection - Span
|
FE-LOF
|
Far End LOF
|
FE-LOS
|
Far End LOS
|
FE-MANWKSWPR-RING
|
Far End Manual Switch Of Working Facility To Protection - Ring
|
FE-MANWKSWPR-SPAN
|
Far End Manual Switch Of Working Facility To Protection - Span
|
FEC-MISM
|
FEC Mismatch
|
FEPRLF
|
Far End Protection Line Failure
|
FORCED-REQ
|
Forced Switch Request
|
FORCED-REQ-RING
|
Forced Switch Request On Ring
|
FORCED-REQ-SPAN
|
Forced Switch Request On Span
|
FRCDSWTOINT
|
Forced Switch To Internal Clock
|
FRCDSWTOPRI
|
Forced Switch To Primary Reference
|
FRCDSWTOSEC
|
Forced Switch To Second Reference
|
FRCDSWTOTHIRD
|
Forced Switch To Third Reference
|
FRNGSYNC
|
Free Running Synchronization Mode
|
FSTSYNC
|
Fast Start Synchronization Mode
|
FULLPASSTHR-BI
|
Bidirectional Full Pass Through Is Active
|
GCC-EOC
|
GCC Termination Failure
|
GE-OOSYNC
|
GigaBit Ethernet Out of Sync
|
HI-LASERBIAS
|
Equipment High Laser Bias
|
HI-RXPOWER
|
Equipment High Rx power
|
HI-TXPOWER
|
Equipment High Tx power
|
HIBATVG
|
High Volt
|
HITEMP
|
High Temperature
|
HLDOVRSYNC
|
Holdover Synchronization Mode
|
I-HITEMP
|
Industrial High Temperature
|
IMPROPRMVL
|
Improper Removal
|
INC-GFP-OUTOFFRAME
|
Out Of Frame Detected by GFP Receiver
|
INC-GFP-SIGLOSS
|
Client Signal Loss Frames Detected by GFP Receiver
|
INC-ISD
|
DS3 Idle Condition
|
INC-SIGLOSS
|
Incoming Signal Loss on Fibre Channel Interface
|
INC-SYNCLOSS
|
Incoming Synchronization Loss on Fibre Channel Interface
|
INC_GFP_SYNCLOSS
|
Client Synchronization Loss Frames Detected by GFP Receiver
|
INHSWPR
|
Inhibit Switch To Protect Request On Equipment
|
INHSWWKG
|
Inhibit Switch To Working Request On Equipment
|
INTRUSION-PSWD
|
Security Intrusion Attempt Detected - See Audit Log
|
INVMACADR
|
Invalid MAC Address
|
IOSCFGCOPY
|
Ios Config Copy In Progress
|
KB-PASSTHR
|
K Bytes Pass Through Is Active
|
KBYTE-APS-CHANNEL-FAILURE
|
Kbyte Channel Failure
|
LAN-POL-REV
|
Lan Connection Polarity Reversed
|
LASEREOL
|
Laser Approaching End of Life
|
LKOUTPR-S
|
Lockout Of Protection - Span
|
LMP-HELLODOWN
|
LMP Hello FSM to Control Channel down
|
LMP-NDFAIL
|
LMP Neighbor Discovery has failed
|
LO-RXPOWER
|
Equipment Low Rx power
|
LO-TXPOWER
|
Equipment Low Tx power
|
LOA
|
Loss of Alignment
|
LOC
|
Loss of Channel
|
LOCKOUT-REQ
|
Lockout Switch Request On Facility or Equipment
|
LOCKOUT-REQ-RING
|
Lockout Switch Request On Ring
|
LOF
|
Loss Of Frame
|
LOM
|
Loss of Multi-Frame
|
LOP-P
|
Loss Of Pointer - Path
|
LOP-V
|
Loss Of Pointer - VT
|
LOS
|
Loss Of Signal
|
LPBKCRS
|
Cross-connect Loopback
|
LPBKDS1FEAC
|
DS1 Loopback Due To FEAC Command
|
LPBKDS1FEAC-CMD
|
DS1 Loopback Command Sent To Far End
|
LPBKDS3FEAC
|
DS3 Loopback Due To FEAC Command
|
LPBKDS3FEAC-CMD
|
DS3 Loopback Command Sent To Far End
|
LPBKFACILITY
|
Facility Loopback
|
LPBKTERMINAL
|
Terminal Loopback
|
LWBATVG
|
Low Volt
|
MAN-REQ
|
Manual Switch Request
|
MANRESET
|
Manual System Reset
|
MANSWTOINT
|
Manual Switch To Internal Clock
|
MANSWTOPRI
|
Manual Switch To Primary Reference
|
MANSWTOSEC
|
Manual Switch To Second Reference
|
MANSWTOTHIRD
|
Manual Switch To Third Reference
|
MANUAL-REQ-RING
|
Manual Switch Request On Ring
|
MANUAL-REQ-SPAN
|
Manual Switch Request On Span
|
MEA
|
Mismatch Of Equipment And Attributes
|
MEM-GONE
|
Free Memory On Card Near Zero
|
MEM-LOW
|
Free Memory On Card Very Low
|
MFGMEM
|
Manufacturing Data Memory (EEPROM Failure
|
NO-CONFIG
|
No Startup Config
|
NTWTPINC
|
Network Topology Incomplete
|
OCHNC-ACTIV-FAIL
|
Optical Channel Activation Failure
|
OCHNC-DEACTIV-FAIL
|
Optical Channel De-Activation Failure
|
OCHNC-FAIL
|
Optical Channel Connection Failure
|
OCHNC-INC
|
Optical Channel Incomplete
|
ODUK-AIS-PM
|
ODUk: Alarm Indication Signal
|
ODUK-BDI-PM
|
ODUk: PM Backward Defect Indication
|
ODUK-LCK-PM
|
ODUk: Locked Defect - PM
|
ODUK-OCI-PM
|
ODUk: Open Connection Indication
|
ODUK-SD-PM
|
ODUk: Signal Degrade
|
ODUK-SF-PM
|
ODUk: Signal Failure
|
ODUK-TIM-PM
|
ODUk: Trail Trace Identifier Mismatch
|
OOU-TPT
|
Out of Use - Transport Failure
|
OPTNTWMIS
|
Optical Network Type Mismatch
|
OTUK-AIS
|
OTUk: Alarm Indication Signal
|
OTUK-BDI
|
OTUk: Backward Defect Indication
|
OTUK-LOF
|
OTUk: Loss Of Frame
|
OTUK-SD
|
OTUk: Signal Degrade
|
OTUK-SF
|
OTUk: Signal Failure
|
OTUK-TIM
|
OTUk: Trail Trace Identifier Mismatch
|
OUT-OF-SYNC
|
8B10B Out of Sync
|
PDI-P
|
Payload Defect Indication - Path
|
PEER-NORESPONSE
|
Peer Card Not Responding
|
PLM-P
|
Payload Label Mismatch - Path
|
PLM-V
|
Signal Label Mismatch Failure - Payload Label Mismatch - VT
|
PORT-CODE-MISM
|
Pluggable Port security code mismatch
|
PORT-COMM-FAIL
|
Module Communication Failure
|
PORT-MISMATCH
|
Pluggable Port rate mismatch
|
PORT-MISSING
|
Pluggable Port missing
|
PRC-DUPID
|
Duplicate Node ID
|
PROTNA
|
Protection Unit Not Available
|
PTIM
|
Payload Type Identifier Mismatch
|
PWR-REDUN
|
Redundant Power Capability Lost
|
RAI
|
Remote Alarm Indication
|
RCVR-MISS
|
Facility Termination Equipment - Receiver Missing
|
RFI
|
Remote Failure Indication
|
RFI-L
|
Remote Failure Indication - Line
|
RFI-P
|
One-Bit Remote Failure Indication - Path
|
RFI-V
|
Remote Failure Indication - VT
|
RING-ID-MIS
|
Ring Id Mismatch
|
RING-MISMATCH
|
Far End Of Fiber Is Provisioned With Different Ring ID
|
RING-SW-EAST
|
Ring Switch Is Active On The East Side
|
RING-SW-WEST
|
Ring Switch Is Active On The West Side
|
RSVP-HELLODOWN
|
RSVP Hello FSM to Neighbor down
|
RUNCFG-SAVENEED
|
Need to Save Running Config
|
SD
|
Signal Degrade
|
SD-L
|
BER Threshold Exceeded For Signal Degrade - Line
|
SD-P
|
BER Threshold Exceeded For Signal Degrade - Path
|
SF
|
Signal Failure
|
SF-L
|
BER Threshold Exceeded For Signal Failure - Line
|
SF-P
|
BER Threshold Exceeded For Signal Failure - Path
|
SFTWDOWN
|
Software Download In Progress
|
SNTP-HOST
|
SNTP Host Failure
|
SPAN-SW-EAST
|
Span Switch Is Active On The East Side
|
SPAN-SW-WEST
|
Span Switch Is Active On The West Side
|
SQM
|
Sequence Mismatch
|
SQUELCH
|
Ring Is Squelching Traffic
|
SQUELCHED
|
Equipment Squelched
|
SSM-DUS
|
Do Not Use For Synchronization
|
SSM-FAIL
|
Failed To Receive Synchronization Status Message
|
SSM-LNC
|
G812 - Local Node Clock traceable
|
SSM-OFF
|
Synchronization Status Messages Are Disabled On This Interface
|
SSM-PRC
|
G811 - Primary Reference Clock traceable
|
SSM-PRS
|
Stratum 1 Primary Reference Source Traceable
|
SSM-RES
|
Reserved For Network Synchronization Use
|
SSM-SDH-TN
|
G812 - Transit Node Clock traceable
|
SSM-SETS
|
G813 - Synchronous Equipment Timing Source traceable
|
SSM-SMC
|
SONET Minimum Clock Traceable
|
SSM-ST2
|
Stratum 2 Traceable
|
SSM-ST3
|
Stratum 3 Traceable
|
SSM-ST3E
|
Stratum 3E Traceable
|
SSM-ST4
|
Stratum 4 Traceable
|
SSM-STU
|
Synchronized - Traceability Unknown
|
SSM-TNC
|
Transit Node Clock Traceable
|
SWMTXMOD
|
Switching Matrix Module Failure
|
SWTOPRI
|
Switch To Primary Reference
|
SWTOSEC
|
Switch To Second Reference
|
SWTOTHIRD
|
Switch To Third Reference
|
SYNC-FREQ
|
Synchronization Reference Frequency Out Of Bounds
|
SYNCPRI
|
Primary Synchronization Reference Failure
|
SYNCSEC
|
Secondary Synchronization Reference Failure
|
SYNCTHIRD
|
Third Synchronization Reference Failure
|
SYSBOOT
|
System Reboot
|
TIM
|
TIM Section - Trace Identifier Mismatch Failure
|
TIM-MON
|
TIM Section Monitor - Trace Identifier Mismatch Failure
|
TIM-P
|
STS Path Trace Identifier Mismatch
|
TPTFAIL
|
Transport layer failure
|
TRMT
|
Transmit Failure
|
TRMT-MISS
|
Facility Termination Equipment - Transmitter Missing
|
TUNDERRUN
|
Ether tx underrun
|
TX-AIS
|
Alarm Indication Signal in TX
|
TX-RAI
|
Remote Alarm Indication in TX
|
UNC-WORD
|
FEC Uncorrected Word
|
UNEQ-P
|
Unequipped - Path
|
UNEQ-V
|
Signal Label Mismatch Failure - Unequipped VT
|
VCG-DEG
|
VCAT Group Degraded
|
VCG-DOWN
|
VCAT Group Down
|
WKSWPR
|
Switched To Protection
|
WTR
|
Wait To Restore
|
WVL-MISMATCH
|
Equipment Wavelength Mismatch
|
4.5 Access Identifiers
The AID code directs an input command to its intended physical or data entity inside the NE. Equipment modules and facilities are typical examples of entities addressed by the access code. The AIDs in this section apply to the ONS SONET 15454, 15327, 15310-CL, and 15600 except where noted.
4.5.1 ALL
Table 4-16 ALL
AID
|
Pattern
|
AidUnionId
|
FACILITY
STS
VT
|
|
AidUnionId1
|
BLSR
|
|
BAND
|
ALL
BAND-{1-6,12-17}-{1-4}-ALL
BAND-{1-6,12-17}-{1-4}-{RX,TX}
BAND-{1-6,12-17}-{1}-ALL
BAND-{1-6,12-17}-{1}-{RX,TX}
|
|
BITS
|
ALL
BITS-ALL
BITS-{1,2}
SYNC-BITS {1,2}
|
|
BLSR
|
ALL
BLSR-RINGID
|
|
CHANNEL
|
ALL
CHAN-{1-6,12-17}-ALL
CHAN-{1-6,12-17}-{1-32}-ALL
CHAN-{1-6,12-17}-{1-32}-{RX,TX}
CHAN-{1-6,12-17}-{1-4}-ALL
CHAN-{1-6,12-17}-{1-4}-{RX,TX}
CHAN-{1-6,12-17}-{2,3}
CHAN-{1-6,12-17}-{2,5}
|
|
COM
|
Common
|
|
CrossConnectId
|
FACILITY
STS
|
|
CrossConnectId1
|
VCM
FACILITY
STS
VT
|
|
DS1
|
ALL
DS1-{1-6,12-17}-{1-12,13,15,17,19,21,23,25,27,29,31,33,35}-{1-28}
DS1-{1-6,12-17}-{1-12,13,15,17,19,21,23}-{1-28}
DS1-{1-6,12-17}-{1-6}-{1-28}
|
ENV
|
ALL
ENV-IN-ALL
ENV-IN-{1-20}
ENV-IN-{1-32}
ENV-IN-{1-3}
ENV-IN-{1-4}
|
ENV-IN-{1-6}
ENV-OUT-ALL
ENV-OUT-{1-16}
ENV-OUT-{1-2}
ENV-OUT-{1-4}
ENV-{IN,OUT}-{1-16}
|
EQPT
|
AIP
ALL
BIC-ALL
BIC-{A,B}
BP
FAN
PIM-{1-4,11-14}-ALL
PIM-{1-4,11-14}-{1-4}
PPM-1-{1,2}
PPM-2-{1,2}
PPM-{1-4,11-14}-{1-4}-ALL
PPM-{1-4,11-14}-{1-4}-{1-4}
|
PPM-{1-6,12-17}-{1-4}
PPM-{1-6,12-17}-{1-8}
PWR-ALL
PWR-{A,B}
SLOT-ALL
SLOT-{1-14}
SLOT-{1-17}
SLOT-{1-2}
SLOT-{1-4,11-14}
SLOT-{1-6,12-17}
SLOT-{1-8}
|
FACILITY
|
ALL
EC1-{2}-{1-3}
FAC-{1-4,11-14}-ALL
FAC-{1-4,11-14}-{1-16}
FAC-{1-4,11-14}-{1-4}
FAC-{1-4,11-14}-{1-4}-{1-4}-{1}
FAC-{1-4,14-17}-{1-8}
FAC-{1-4}-1
FAC-{1-4}-{1-4}
FAC-{1-6,12-17}-1
FAC-{1-6,12-17}-ALL
FAC-{1-6,12-17}-{0-11}
FAC-{1-6,12-17}-{0-1}
FAC-{1-6,12-17}-{1-12,14,16,18,20,22,24,26,28,30,32,34,36}
FAC-{1-6,12-17}-{1-12,14,16,18,20,22,24}
FAC-{1-6,12-17}-{1-12}
FAC-{1-6,12-17}-{1-4}
FAC-{1-6,12-17}-{1-6}
|
FAC-{1-6,12-17}-{1}
FAC-{1-6}-ALL
FAC-{5,6,12,13}-{1}
FAC-{5-6}-{1-28}
FAC-{5-6}-{1-3}
FAC-{8,10}-{1}
FSTE-{1}-{0-7}
FSTE-{1}-{1-8}
OC12-{2}-{1-2}-{1}
OC3-{2}-{1-2}-{1}
T1-{2}-{1-21}
T3-{2}-{1-3}
VFAC-{1-4,11-14}-{1-4}-{1-4}-1
VFAC-{1-6,12-17}-{0-1}
VFAC-{1-6,12-17}-{1,2}
VFAC-{1-6,12-17}-{1,2}-{1,8}
VFAC-{1}-{0-1}
VFAC-{1}-{1-8}
|
LINE
|
ALL
LINE-{1-6,12-17}-{1-2}-ALL
LINE-{1-6,12-17}-{1-2}-{RX,TX}
LINE-{1-6,12-17}-{1-3}-ALL
LINE-{1-6,12-17}-{1-3}-{RX,TX}
LINE-{8,10}-{1}-ALL
LINE-{8,10}-{1}-{RX,TX}
|
|
OSC
|
ALL
OSC-RINGID
|
|
OPM
|
OPM-{1-5,12-16}--{1530.33,1531.12,1531.90,1532.68,1534.25,1535.04,1535.82,
1536.61,1538.19,1538.98,1539.77,1540.56,1542.14,1542.94,1543.73,1544.53,
1546.12,1546.92,1547.72,1548.51,1550.12,1550.92,1551.72,1552.52,1554.13,
1554.94,1555.75,1556.55,1558.17,1558.98,1559.79,1560.61}
|
PRSLOT
|
NULL
SLOT-1
SLOT-13
SLOT-15
SLOT-17
SLOT-3
SLOT-5
|
|
RFILE
|
RFILE-DB
RFILE-PKG
|
|
STS
|
ALL
FAC-{1-4,11-14}-{1-4}-{1-4}-{1}
FAC-{1-6,12-17}-{1-4}
STS-{1-4,11-14}-{1-16}-1
STS-{1-4,11-14}-{1-16}-ALL
STS-{1-4,11-14}-{1-16}-{1,13,25,37}
STS-{1-4,11-14}-{1-16}-{1,25}
STS-{1-4,11-14}-{1-16}-{1,4,7,10,-,46}
STS-{1-4,11-14}-{1-4}-1
STS-{1-4,11-14}-{1-4}-ALL
STS-{1-4,11-14}-{1-4}-{1,13,25,37,-,181}
STS-{1-4,11-14}-{1-4}-{1,25,49,73,-,169}
STS-{1-4,11-14}-{1-4}-{1,4,7,10,-,190}
STS-{1-4,11-14}-{1-4}-{1,49,97,145}
STS-{1-4,11-14}-{1-4}-{1,4}-{1}
STS-{1-4,11-14}-{1-4}-{1,4}-{1}-{1,13,25,37}
STS-{1-4,11-14}-{1-4}-{1,4}-{1}-{1,25}
STS-{1-4,11-14}-{1-4}-{1,4}-{1}-{1,4,13,16,25,28,37,40}
STS-{1-4,11-14}-{1-4}-{1,4}-{1}-{1,4,7,10,13,16,19,22,25,28,31,34,37,40,43,46}
STS-{1-4,11-14}-{1-4}-{1,4}-{1}-{1,4,7}
STS-{1-4,11-14}-{1-4}-{1,4}-{1}-{1,4}
STS-{1-4,11-14}-{1-4}-{1,4}-{1}-{1-12}
STS-{1-4,11-14}-{1-4}-{1,4}-{1}-{1-3}
STS-{1-4,11-14}-{1-4}-{1,4}-{1}-{1-48}
STS-{1-4,11-14}-{1-4}-{1-192}
STS-{1-4,11-14}-{1-4}-{1-4}-{1}-ALL
STS-{1-4,11-14}-{1-4}-{1-4}-{1}-{1,4,7,13,16,19,25,28,31,43}
STS-{1-4,14-17}-{1-16}-{1-48}
STS-{1-4,14-17}-{1-4}-1
STS-{1-4,14-17}-{1-4}-ALL
STS-{1-4,14-17}-{1-4}-{1,4,7,10}
STS-{1-4,14-17}-{1-4}-{1,4,7}
STS-{1-4,14-17}-{1-4}-{1-3}
|
STS (continued)
|
STS-{1-4,14-17}-{1-8}-1
STS-{1-4,14-17}-{1-8}-ALL
STS-{1-4,14-17}-{1-8}-{1-3}
STS-{1-4}-1-1
STS-{1-4}-1-ALL
STS-{1-4}-1-{1,13,25,37}
STS-{1-4}-1-{1,4,7,10,-.,46}
STS-{1-4}-1-{1,4,7,10}
STS-{1-4}-1-{1,7,13,19,-,43}
STS-{1-4}-1-{1,7}
STS-{1-4}-1-{1-12}
STS-{1-4}-1-{1-48}
STS-{1-6,12-17}-1
STS-{1-6,12-17}-1-1
STS-{1-6,12-17}-1-ALL
STS-{1-6,12-17}-1-{1,13,25,37}
STS-{1-6,12-17}-1-{1,4,10,13,16,19,25,28,37,40}
STS-{1-6,12-17}-1-{1,4,7,10,13,16,19,22,25}
STS-{1-6,12-17}-1-{1,4,7,10-46}
STS-{1-6,12-17}-1-{1,4,7,10}
STS-{1-6,12-17}-1-{1,4,7,13,16,19,25,28,37,40,43}
STS-{1-6,12-17}-1-{1,4,7}
STS-{1-6,12-17}-1-{1,4}
STS-{1-6,12-17}-1-{1-12}
STS-{1-6,12-17}-1-{1-48}
STS-{1-6,12-17}-ALL
STS-{1-6,12-17}-{1-12}-1
STS-{1-6,12-17}-{1-24}-1
STS-{1-6,12-17}-{1-36}-1
STS-{1-6,12-17}-{1-4}-1
STS-{1-6,12-17}-{1-4}-ALL
STS-{1-6,12-17}-{1-4}-{1,4,7,10-46}
STS-{1-6,12-17}-{1-4}-{1,4,7}
STS-{1-6,12-17}-{1-4}-{1,4}
|
STS (continued)
|
STS-{1-6,12-17}-{1-4}-{1-12}
STS-{1-6,12-17}-{1-6}
STS-{2}-{1-2}-{1}-{1,4,7,10}
STS-{2}-{1-2}-{1}-{1,7}
STS-{2}-{1-2}-{1}-{1-12}
STS-{2}-{1-2}-{1}-{1-3}
STS-{2}-{1-2}-{1}-{1}
STS-{2}-{1-3}-{1}
STS-{2}-{1}
STS-{5,6,12,13}-1-1
STS-{5,6,12,13}-1-{1,13,25,37-180}
STS-{5,6,12,13}-1-{1,13,25,37}
STS-{5,6,12,13}-1-{1,4,7,10,13,16,19,22,25}
STS-{5,6,12,13}-1-{1,4,7,10-190}
STS-{5,6,12,13}-1-{1,4,7,10-46}
STS-{5,6,12,13}-1-{1,4,7,13,16,19,25,28,37,40,43}
STS-{5,6,12,13}-1-{1,49,97,145}
STS-{5,6,12,13}-1-{1-192}
STS-{5,6,12,13}-1-{1-48}
STS-{5,6}-1
STS-{5,6}-{1-4}-1
STS-{5-6}-ALL
VFAC-{1-6,12-17}-{0-1}
|
SYN
|
SYNC-NE
|
|
SYN_SRC
|
BITS-1
BITS-2
FAC-{1-4,11-14}-{1-16}
FAC-{1-4,11-14}-{1-4}
FAC-{1-4}-1
FAC-{1-4}-{1-4}
FAC-{1-6,12-17}-{1-4}
FAC-{1-6,12-17}-{1}
|
FAC-{5,6,12,13}-{1}
INTERNAL
NONE
OC12-{2}-{1-2}-{1}
OC3-{2}-{1-2}-{1}
SYNC-NE
T1-{2}-{1-21}
|
SYNC_REF
|
ALL
SYNC-ALL
SYNC-NE
SYNC-{BITS1,BITS2}
|
|
SYNCSW
|
INT
PRI
SEC
THIRD
|
|
UDC
|
ALL
UDC-{F,DCC}-{A,B}
|
|
VT
|
ALL
VT1-{1-4,14-17}-{1-8}-{1-3}-{1-7}-{1-4}
VT1-{1-4}-1-{1-12}-{1-7}-{1-4}
VT1-{1-4}-1-{1-48}-{1-7}-{1-4}
VT1-{1-4}-{1-4}-{1-3}-{1-7}-{1-4}
VT1-{1-6,12-17}-1-{1-12}-{1-7}-{1-4}
VT1-{1-6,12-17}-1-{1-48}-{1-7}-{1-4}
VT1-{1-6,12-17}-1-{1-7}-{1-2}
VT1-{1-6,12-17}-{1-12}-1-{1-7}-{1-4}
VT1-{1-6,12-17}-{1-24}-1-{1-7}-{1-4}
VT1-{1-6,12-17}-{1-36}-1-{1-7}-{1-4}
VT1-{1-6,12-17}-{1-4}-{1-12}-{1-7}-{1-4}
VT1-{1-6,12-17}-{1-4}-{1-3}-{1-7}-{1-4}
VT1-{1-6,12-17}-{1-6}-{1-7}-{1-4}
VT1-{2}-{1-2}-{1}-{1-12}-{1-7}-{1-4}
|
VT1-{2}-{1-2}-{1}-{1-3}-{1-7}-{1-4}
VT1-{2}-{1-3}-{1}-{1-7}-{1-4}
VT1-{2}-{1}-{1-7}-{1-3}
VT1-{5,6,12,13}-1-{1-192}-{1-7}-{1-4}
VT1-{5,6,12,13}-1-{1-48}-{1-7}-{1-4}
VT1-{5-6}-1-{1-7}-{1-2}
VT1-{5-6}-1-{1-7}-{1-4}
VT2-{1-4,14-17}-{1-8}-{1-3}-{1-7}-{1-3}
VT2-{1-6,12-17}-1-{1-12}-{1-7}-{1-3}
VT2-{1-6,12-17}-1-{1-48}-{1-7}-{1-3}
VT2-{1-6,12-17}-{1-4}-{1-12}-{1-7}-{1-3}
VT2-{1-6,12-17}-{1-4}-{1-3}-{1-7}-{1-3}
VT2-{5,6,12,13}-1-{1-192}-{1-7}-{1-3}
VT2-{5,6,12,13}-1-{1-48}-{1-7}-{1-3}
|
WDMANS
|
AONS-{E,W}
WDMANS-{E,W}
|
|
WLEN
|
WLEN-{E,W}-{ADD,DROP,EXP}-{1530.33,1531.12,1531.90,1532.68,1534.25,1535.04,1535.82,1536.61,1538.19,1538.98,1539.77,1540.56,1542.14,1542.94,1543.73,1544.53, 1546.12,1546.92,,1547.72,1548.51,1550.12,1550.92,1551.72,1552.52,1554.13,1554.94, 1555.75,1556.55,1558.17,1558.98,1559.79,1560.61}
|
4.5.2 AidUnionId
Table 4-17 AidUnionId
AID
|
Patterns
|
Facility
|
ALL
EC1-{2}-{1-3}
FAC-{1-4,11-14}-ALL
FAC-{1-4,11-14}-{1-16}
FAC-{1-4,11-14}-{1-4}
FAC-{1-4,11-14}-{1-4}-{1-4}-{1}
FAC-{1-4,14-17}-{1-8}
FAC-{1-4}-1
FAC-{1-4}-{1-4}
FAC-{1-6,12-17}-1
FAC-{1-6,12-17}-ALL
FAC-{1-6,12-17}-{0-11}
FAC-{1-6,12-17}-{0-1}
FAC-{1-6,12-17}-{1-12,14,16,18,20,22,24,26,28,30,32,34,36}
FAC-{1-6,12-17}-{1-12,14,16,18,20,22,24}
FAC-{1-6,12-17}-{1-12}
FAC-{1-6,12-17}-{1-4}
FAC-{1-6,12-17}-{1-6}
|
FAC-{1-6,12-17}-{1}
FAC-{1-6}-ALL
FAC-{5,6,12,13}-{1}
FAC-{5-6}-{1-28}
FAC-{5-6}-{1-3}
FAC-{8,10}-{1}
FSTE-{1}-{0-7}
FSTE-{1}-{1-8}
OC12-{2}-{1-2}-{1}
OC3-{2}-{1-2}-{1}
T1-{2}-{1-21}
T3-{2}-{1-3}
VFAC-{1-4,11-14}-{1-4}-{1-4}-1
VFAC-{1-6,12-17}-{0-1}
VFAC-{1-6,12-17}-{1,2}
VFAC-{1-6,12-17}-{1,2}-{1,8}
VFAC-{1}-{0-1}
VFAC-{1}-{1-8}
|
STS
|
ALL
FAC-{1-4,11-14}-{1-4}-{1-4}-{1}
FAC-{1-6,12-17}-{1-4}
STS-{1-4,11-14}-{1-16}-1
STS-{1-4,11-14}-{1-16}-ALL
STS-{1-4,11-14}-{1-16}-{1,13,25,37}
STS-{1-4,11-14}-{1-16}-{1,25}
STS-{1-4,11-14}-{1-16}-{1,4,7,10,-,46}
STS-{1-4,11-14}-{1-4}-1
STS-{1-4,11-14}-{1-4}-ALL
STS-{1-4,11-14}-{1-4}-{1,13,25,37,-,181}
STS-{1-4,11-14}-{1-4}-{1,25,49,73,-,169}
STS-{1-4,11-14}-{1-4}-{1,4,7,10,-,190}
STS-{1-4,11-14}-{1-4}-{1,49,97,145}
|
|
STS (continued)
|
STS-{1-4,11-14}-{1-4}-{1,4}-{1}
STS-{1-4,11-14}-{1-4}-{1,4}-{1}-{1,13,25,37}
STS-{1-4,11-14}-{1-4}-{1,4}-{1}-{1,25}
STS-{1-4,11-14}-{1-4}-{1,4}-{1}-{1,4,13,16,25,28,37,40}
STS-{1-4,11-14}-{1-4}-{1,4}-{1}-{1,4,7,10,13,16,19,22,25,28,31,34,37,40,43,46}
STS-{1-4,11-14}-{1-4}-{1,4}-{1}-{1,4,7}
STS-{1-4,11-14}-{1-4}-{1,4}-{1}-{1,4}
STS-{1-4,11-14}-{1-4}-{1,4}-{1}-{1-12}
STS-{1-4,11-14}-{1-4}-{1,4}-{1}-{1-3}
STS-{1-4,11-14}-{1-4}-{1,4}-{1}-{1-48}
STS-{1-4,11-14}-{1-4}-{1-192}
STS-{1-4,11-14}-{1-4}-{1-4}-{1}-ALL
STS-{1-4,11-14}-{1-4}-{1-4}-{1}-{1,4,7,13,16,19,25,28,31,43}
STS-{1-4,14-17}-{1-16}-{1-48}
STS-{1-4,14-17}-{1-4}-1
STS-{1-4,14-17}-{1-4}-ALL
STS-{1-4,14-17}-{1-4}-{1,4,7,10}
STS-{1-4,14-17}-{1-4}-{1,4,7}
STS-{1-4,14-17}-{1-4}-{1-3}
STS-{1-4,14-17}-{1-8}-1
STS-{1-4,14-17}-{1-8}-ALL
STS-{1-4,14-17}-{1-8}-{1-3}
STS-{1-4}-1-1
STS-{1-4}-1-ALL
STS-{1-4}-1-{1,13,25,37}
STS-{1-4}-1-{1,4,7,10,-.,46}
STS-{1-4}-1-{1,4,7,10}
STS-{1-4}-1-{1,7,13,19,-,43}
STS-{1-4}-1-{1,7}
STS-{1-4}-1-{1-12}
STS-{1-4}-1-{1-48}
STS-{1-6,12-17}-1
STS-{1-6,12-17}-1-1
STS-{1-6,12-17}-1-ALL
|
STS (continued)
|
STS-{1-6,12-17}-1-{1,13,25,37}
STS-{1-6,12-17}-1-{1,4,10,13,16,19,25,28,37,40}
STS-{1-6,12-17}-1-{1,4,7,10,13,16,19,22,25}
STS-{1-6,12-17}-1-{1,4,7,10-46}
STS-{1-6,12-17}-1-{1,4,7,10}
STS-{1-6,12-17}-1-{1,4,7,13,16,19,25,28,37,40,43}
STS-{1-6,12-17}-1-{1,4,7}
STS-{1-6,12-17}-1-{1,4}
STS-{1-6,12-17}-1-{1-12}
STS-{1-6,12-17}-1-{1-48}
STS-{1-6,12-17}-ALL
STS-{1-6,12-17}-{1-12}-1
STS-{1-6,12-17}-{1-24}-1
STS-{1-6,12-17}-{1-36}-1
STS-{1-6,12-17}-{1-4}-1
STS-{1-6,12-17}-{1-4}-ALL
STS-{1-6,12-17}-{1-4}-{1,4,7,10-46}
STS-{1-6,12-17}-{1-4}-{1,4,7}
STS-{1-6,12-17}-{1-4}-{1,4}
STS-{1-6,12-17}-{1-4}-{1-12}
STS-{1-6,12-17}-{1-6}
STS-{2}-{1-2}-{1}-{1,4,7,10}
STS-{2}-{1-2}-{1}-{1,7}
STS-{2}-{1-2}-{1}-{1-12}
STS-{2}-{1-2}-{1}-{1-3}
STS-{2}-{1-2}-{1}-{1}
STS-{2}-{1-3}-{1}
STS-{2}-{1}
STS-{5,6,12,13}-1-1
STS-{5,6,12,13}-1-{1,13,25,37-180}
STS-{5,6,12,13}-1-{1,13,25,37}
STS-{5,6,12,13}-1-{1,4,7,10,13,16,19,22,25}
STS-{5,6,12,13}-1-{1,4,7,10-190}
STS-{5,6,12,13}-1-{1,4,7,10-46}
STS-{5,6,12,13}-1-{1,4,7,13,16,19,25,28,37,40,43}
|
STS (continued)
|
STS-{5,6,12,13}-1-{1,49,97,145}
STS-{5,6,12,13}-1-{1-192}
STS-{5,6,12,13}-1-{1-48}
STS-{5,6}-1
STS-{5,6}-{1-4}-1
STS-{5-6}-ALL
VFAC-{1-6,12-17}-{0-1}
|
|
VT
|
ALL
VT1-{1-4,14-17}-{1-8}-{1-3}-{1-7}-{1-4}
VT1-{1-4}-1-{1-12}-{1-7}-{1-4}
VT1-{1-4}-1-{1-48}-{1-7}-{1-4}
VT1-{1-4}-{1-4}-{1-3}-{1-7}-{1-4}
VT1-{1-6,12-17}-1-{1-12}-{1-7}-{1-4}
VT1-{1-6,12-17}-1-{1-48}-{1-7}-{1-4}
VT1-{1-6,12-17}-1-{1-7}-{1-2}
VT1-{1-6,12-17}-{1-12}-1-{1-7}-{1-4}
VT1-{1-6,12-17}-{1-24}-1-{1-7}-{1-4}
VT1-{1-6,12-17}-{1-36}-1-{1-7}-{1-4}
VT1-{1-6,12-17}-{1-4}-{1-12}-{1-7}-{1-4}
VT1-{1-6,12-17}-{1-4}-{1-3}-{1-7}-{1-4}
VT1-{1-6,12-17}-{1-6}-{1-7}-{1-4}
VT1-{2}-{1-2}-{1}-{1-12}-{1-7}-{1-4}
|
VT1-{2}-{1-2}-{1}-{1-3}-{1-7}-{1-4}
VT1-{2}-{1-3}-{1}-{1-7}-{1-4}
VT1-{2}-{1}-{1-7}-{1-3}
VT1-{5,6,12,13}-1-{1-192}-{1-7}-{1-4}
VT1-{5,6,12,13}-1-{1-48}-{1-7}-{1-4}
VT1-{5-6}-1-{1-7}-{1-2}
VT1-{5-6}-1-{1-7}-{1-4}
VT2-{1-4,14-17}-{1-8}-{1-3}-{1-7}-{1-3}
VT2-{1-6,12-17}-1-{1-12}-{1-7}-{1-3}
VT2-{1-6,12-17}-1-{1-48}-{1-7}-{1-3}
VT2-{1-6,12-17}-{1-4}-{1-12}-{1-7}-{1-3}
VT2-{1-6,12-17}-{1-4}-{1-3}-{1-7}-{1-3}
VT2-{5,6,12,13}-1-{1-192}-{1-7}-{1-3}
VT2-{5,6,12,13}-1-{1-48}-{1-7}-{1-3}
|
4.5.3 AidUnionId1
Table 4-18 AidUnionId1
AID
|
Patterns
|
BLSR
|
ALL
BLSR-RINGID
|
4.5.4 BAND
(Cisco ONS 15454 only)
The BAND AID is used to access Optical Multiplex Section (OMS) layer of Optical Network units.
Table 4-19 BAND
Pattern
|
Description
|
ALL
|
All of the OMSs of the NE. The ALL AID is applicable for retrieve-only commands
|
BAND-{1-6,12-17}-{1-4}-ALL
|
All the Channels in a Band OADM (1Bn, 4Bn) units
|
BAND-{1-6,12-17}-{1-4}-{RX,TX}
|
The Receive/Transmit Channels in a Band OADM (1Bn, 4Bn) units
|
BAND-{1-6,12-17}-{1}-ALL
|
All the Channels in an Optical Multiplexer/Demultiplexer (4Ch) units
|
BAND-{1-6,12-17}-{1}-{RX,TX}
|
The Receive/Transmit Channels in an Optical Multiplexer/Demultiplexer (4Ch) units
|
4.5.5 BITS
AID for BITS (Building Integrated Timing Supply).
Table 4-20 BITS
Pattern
|
Description
|
ALL
|
The ALL AID is applicable to RTRV commands only (RTRV-BITS and RTRV-ALM/COND-BITS). The All AID is equivalent to BITS-ALL for these commands. For RTRV-ALM/COND-SYNCN, the ALL AID translates to BITS-ALL, SYNC-BITS1, and SYNC-BITS2
|
BITS-ALL
|
BITS AIDS of both BITS-1 and BITS-2 in the RTRV-BITS command
|
BITS-{1,2}
|
Individual BITS AID
Note ONS 15310-CL does not support SYNC-BITS2.
|
SYNC-BITS{1,2}
|
BITS-OUT AIDs of BITS-1 and BITS-2. These AIDs are applicable only in ED/RTRV-BITS commands and are used for setting and retrieving the BITS-OUT parameters.
|
4.5.6 BLSR
BLSR AIDs are used to access the specific BLSR of the NE. Applies to ONS 15454, 15454, and 15600.
Table 4-21 BLSR
Pattern
|
Description
|
ALL
|
All the BLSRs in the NE. The ALL AID is applicable for retrieve-only commands like RTRV-<MOD_RING> (BLSR)
|
BLSR-RINGID
|
RINGID is a string of up to six characters. Valid characters are [A-Z,0-9] (case insensitive)
|
4.5.7 CHANNEL
(Cisco ONS 15454 only)
Accesses the Optical Channels (OCH) layer of Optical Network/Client units.
Table 4-22 CHANNEL
CHANNEL Values
|
Description
|
ALL
|
ALL OCHs of the NE. The ALL AID is applicable for retrieve-only commands
|
CHAN-{1-6,12-17}-ALL
|
All the Channels of an Optical Transponder/Muxponder. The format is CHAN-[SLOT]-ALL
|
CHAN-{1-6,12-17}-{1-32}-ALL
|
All the Channels in an Optical Multiplexer/Demultiplexer (32Ch) units. The format is CHAN-[SLOT]-[PORT]-ALL
|
CHAN-{1-6,12-17}-{1-32}-{RX,TX}
|
The Receive/Transmit Channels in an Optical Multiplexer/Demultiplexer (32Ch) units. The format is CHAN-[SLOT]-[PORT]-[DIRECTION]
|
CHAN-{1-6,12-17}-{1-4}-ALL
|
All the Channels in an OADM (1Ch, 2Ch, 4Ch) units and Optical and Optical Multiplexer/Demultiplexer (4Ch) units. The format is CHAN-[SLOT]-[PORT]-ALL
|
CHAN-{1-6,12-17}-{1-4}-{RX,TX}
|
The Receive/Transmit Channels in an OADM (1Ch, 2Ch, 4Ch) units and Optical Multiplexer/Demultiplexer (4Ch) units. The format is CHAN-[SLOT]-[PORT]-[DIRECTION]
|
CHAN-{1-6,12-17}-{2,3}
|
A single channel of an Optical Transponder/Muxponder. The TXP_MR_10G and TXP_MR_2.5G use CHAN-slot-2 for the 1 DWDM Facility. TXPP_MR_2.5G uses CHAN-slot-{2,3} for the 2 DWDM facilities. The format is CHAN-[SLOT]-[PORT]
|
CHAN-{1-6,12-17}-{2,5}
|
A single channel of an Optical Transponder/Muxponder. The TXP_MR_10G uses CHAN-slot-2 for the 1 DWDM facility. MXP_2.5G_10G uses the CHAN-slot-5 for the 1 DWDM facility. The format is CHAN-[SLOT]-[PORT]
|
4.5.8 COM
Common
Table 4-23 COM
Pattern
|
Description
|
COM
|
Common
|
4.5.9 CrossConnectId
Table 4-24 CrossConnect Id
Pattern
|
Description
|
FACILITY
|
ALL
EC1-{2}-{1-3}
FAC-{1-4,11-14}-ALL
FAC-{1-4,11-14}-{1-16}
FAC-{1-4,11-14}-{1-4}
FAC-{1-4,11-14}-{1-4}-{1-4}-{1}
FAC-{1-4,14-17}-{1-8}
FAC-{1-4}-1
FAC-{1-4}-{1-4}
FAC-{1-6,12-17}-1
FAC-{1-6,12-17}-ALL
FAC-{1-6,12-17}-{0-11}
FAC-{1-6,12-17}-{0-1}
FAC-{1-6,12-17}-{1-12,14,16,18,20,22,24,26,28,30,32,34,36}
FAC-{1-6,12-17}-{1-12,14,16,18,20,22,24}
FAC-{1-6,12-17}-{1-12}
FAC-{1-6,12-17}-{1-4}
FAC-{1-6,12-17}-{1-6}
FAC-{1-6,12-17}-{1}
FAC-{1-6}-ALL
FAC-{5,6,12,13}-{1}
|
Facility
|
FAC-{5-6}-{1-28}
FAC-{5-6}-{1-3}
FAC-{8,10}-{1}
FSTE-{1}-{0-7}
FSTE-{1}-{1-8}
OC12-{2}-{1-2}-{1}
OC3-{2}-{1-2}-{1}
T1-{2}-{1-21}
T3-{2}-{1-3}
VFAC-{1-4,11-14}-{1-4}-{1-4}-1
VFAC-{1-6,12-17}-{0-1}
VFAC-{1-6,12-17}-{1,2}
VFAC-{1-6,12-17}-{1,2}-{1,8}
VFAC-{1}-{0-1}
VFAC-{1}-{1-8}
|
STS
|
ALL
FAC-{1-4,11-14}-{1-4}-{1-4}-{1}
FAC-{1-6,12-17}-{1-4}
STS-{1-4,11-14}-{1-16}-1
STS-{1-4,11-14}-{1-16}-ALL
STS-{1-4,11-14}-{1-16}-{1,13,25,37}
STS-{1-4,11-14}-{1-16}-{1,25}
STS-{1-4,11-14}-{1-16}-{1,4,7,10,-,46}
STS-{1-4,11-14}-{1-4}-1
STS-{1-4,11-14}-{1-4}-ALL
STS-{1-4,11-14}-{1-4}-{1,13,25,37,-,181}
STS-{1-4,11-14}-{1-4}-{1,25,49,73,-,169}
STS-{1-4,11-14}-{1-4}-{1,4,7,10,-,190}
STS-{1-4,11-14}-{1-4}-{1,49,97,145}
STS-{1-4,11-14}-{1-4}-{1,4}-{1}
STS-{1-4,11-14}-{1-4}-{1,4}-{1}-{1,13,25,37}
STS-{1-4,11-14}-{1-4}-{1,4}-{1}-{1,25}
STS-{1-4,11-14}-{1-4}-{1,4}-{1}-{1,4,13,16,25,28,37,40}
STS-{1-4,11-14}-{1-4}-{1,4}-{1}-{1,4,7,10,13,16,19,22,25,28,31,34,37,40,43,46}
STS-{1-4,11-14}-{1-4}-{1,4}-{1}-{1,4,7}
STS-{1-4,11-14}-{1-4}-{1,4}-{1}-{1,4}
STS-{1-4,11-14}-{1-4}-{1,4}-{1}-{1-12}
STS-{1-4,11-14}-{1-4}-{1,4}-{1}-{1-3}
STS-{1-4,11-14}-{1-4}-{1,4}-{1}-{1-48}
STS-{1-4,11-14}-{1-4}-{1-192}
STS-{1-4,11-14}-{1-4}-{1-4}-{1}-ALL
STS-{1-4,11-14}-{1-4}-{1-4}-{1}-{1,4,7,13,16,19,25,28,31,43}
|
STS
|
STS-{1-4,14-17}-{1-16}-{1-48}
STS-{1-4,14-17}-{1-4}-1
STS-{1-4,14-17}-{1-4}-ALL
STS-{1-4,14-17}-{1-4}-{1,4,7,10}
STS-{1-4,14-17}-{1-4}-{1,4,7}
STS-{1-4,14-17}-{1-4}-{1-3}
STS-{1-4,14-17}-{1-8}-1
STS-{1-4,14-17}-{1-8}-ALL
STS-{1-4,14-17}-{1-8}-{1-3}
STS-{1-4}-1-1
STS-{1-4}-1-ALL
STS-{1-4}-1-{1,13,25,37}
STS-{1-4}-1-{1,4,7,10,-.,46}
STS-{1-4}-1-{1,4,7,10}
STS-{1-4}-1-{1,7,13,19,-,43}
STS-{1-4}-1-{1,7}
STS-{1-4}-1-{1-12}
STS-{1-4}-1-{1-48}
STS-{1-6,12-17}-1
STS-{1-6,12-17}-1-1
STS-{1-6,12-17}-1-ALL
STS-{1-6,12-17}-1-{1,13,25,37}
STS-{1-6,12-17}-1-{1,4,10,13,16,19,25,28,37,40}
STS-{1-6,12-17}-1-{1,4,7,10,13,16,19,22,25}
STS-{1-6,12-17}-1-{1,4,7,10-46}
STS-{1-6,12-17}-1-{1,4,7,10}
STS-{1-6,12-17}-1-{1,4,7,13,16,19,25,28,37,40,43}
STS-{1-6,12-17}-1-{1,4,7}
STS-{1-6,12-17}-1-{1,4}
STS-{1-6,12-17}-1-{1-12}
STS-{1-6,12-17}-1-{1-48}
STS-{1-6,12-17}-ALL
|
STS
|
STS-{1-6,12-17}-{1-12}-1
STS-{1-6,12-17}-{1-24}-1
STS-{1-6,12-17}-{1-36}-1
STS-{1-6,12-17}-{1-4}-1
STS-{1-6,12-17}-{1-4}-ALL
STS-{1-6,12-17}-{1-4}-{1,4,7,10-46}
STS-{1-6,12-17}-{1-4}-{1,4,7}
STS-{1-6,12-17}-{1-4}-{1,4}
STS-{1-6,12-17}-{1-4}-{1-12}
STS-{1-6,12-17}-{1-6}
STS-{2}-{1-2}-{1}-{1,4,7,10}
STS-{2}-{1-2}-{1}-{1,7}
STS-{2}-{1-2}-{1}-{1-12}
STS-{2}-{1-2}-{1}-{1-3}
STS-{2}-{1-2}-{1}-{1}
STS-{2}-{1-3}-{1}
STS-{2}-{1}
STS-{5,6,12,13}-1-1
STS-{5,6,12,13}-1-{1,13,25,37-180}
STS-{5,6,12,13}-1-{1,13,25,37}
STS-{5,6,12,13}-1-{1,4,7,10,13,16,19,22,25}
STS-{5,6,12,13}-1-{1,4,7,10-190}
STS-{5,6,12,13}-1-{1,4,7,10-46}
STS-{5,6,12,13}-1-{1,4,7,13,16,19,25,28,37,40,43}
STS-{5,6,12,13}-1-{1,49,97,145}
STS-{5,6,12,13}-1-{1-192}
STS-{5,6,12,13}-1-{1-48}
STS-{5,6}-1
STS-{5,6}-{1-4}-1
STS-{5-6}-ALL
VFAC-{1-6,12-17}-{0-1}
|
4.5.10 CrossConnectId1
Table 4-25 CrossConnectId1
AID
|
Pattern
|
VCM
|
VCM-{1-6,12-17}-{0-1}-ALL
VCM-{1-6,12-17}-{0-1}-{1-256}
VCM-{1-6,12-17}-{1-4}-ALL
VCM-{1-6,12-17}-{1-4}-{1-256}
|
FACILITY
|
ALL
EC1-{2}-{1-3}
FAC-{1-4,11-14}-ALL
FAC-{1-4,11-14}-{1-16}
FAC-{1-4,11-14}-{1-4}
FAC-{1-4,11-14}-{1-4}-{1-4}-{1}
FAC-{1-4,14-17}-{1-8}
FAC-{1-4}-1
FAC-{1-4}-{1-4}
FAC-{1-6,12-17}-1
FAC-{1-6,12-17}-ALL
FAC-{1-6,12-17}-{0-11}
FAC-{1-6,12-17}-{0-1}
FAC-{1-6,12-17}-{1-12,14,16,18,20,22,24,26,28,30,32,34,36}
FAC-{1-6,12-17}-{1-12,14,16,18,20,22,24}
FAC-{1-6,12-17}-{1-12}
FAC-{1-6,12-17}-{1-4}
FAC-{1-6,12-17}-{1-6}
FAC-{1-6,12-17}-{1}
FAC-{1-6}-ALL
FAC-{5,6,12,13}-{1}
FAC-{5-6}-{1-28}
FAC-{5-6}-{1-3}
FAC-{8,10}-{1}
|
Facility (continued)
|
FSTE-{1}-{0-7}
FSTE-{1}-{1-8}
OC12-{2}-{1-2}-{1}
OC3-{2}-{1-2}-{1}
T1-{2}-{1-21}
T3-{2}-{1-3}
VFAC-{1-4,11-14}-{1-4}-{1-4}-1
VFAC-{1-6,12-17}-{0-1}
VFAC-{1-6,12-17}-{1,2}
VFAC-{1-6,12-17}-{1,2}-{1,8}
VFAC-{1}-{0-1}
VFAC-{1}-{1-8}
|
STS
|
ALL
FAC-{1-4,11-14}-{1-4}-{1-4}-{1}
FAC-{1-6,12-17}-{1-4}
STS-{1-4,11-14}-{1-16}-1
STS-{1-4,11-14}-{1-16}-ALL
STS-{1-4,11-14}-{1-16}-{1,13,25,37}
STS-{1-4,11-14}-{1-16}-{1,25}
STS-{1-4,11-14}-{1-16}-{1,4,7,10,-,46}
STS-{1-4,11-14}-{1-4}-1
STS-{1-4,11-14}-{1-4}-ALL
STS-{1-4,11-14}-{1-4}-{1,13,25,37,-,181}
STS-{1-4,11-14}-{1-4}-{1,25,49,73,-,169}
STS-{1-4,11-14}-{1-4}-{1,4,7,10,-,190}
STS-{1-4,11-14}-{1-4}-{1,49,97,145}
STS-{1-4,11-14}-{1-4}-{1,4}-{1}
STS-{1-4,11-14}-{1-4}-{1,4}-{1}-{1,13,25,37}
STS-{1-4,11-14}-{1-4}-{1,4}-{1}-{1,25}
STS-{1-4,11-14}-{1-4}-{1,4}-{1}-{1,4,13,16,25,28,37,40}
STS-{1-4,11-14}-{1-4}-{1,4}-{1}-{1,4,7,10,13,16,19,22,25,28,31,34,37,40,43,46}
STS-{1-4,11-14}-{1-4}-{1,4}-{1}-{1,4,7}
STS-{1-4,11-14}-{1-4}-{1,4}-{1}-{1,4}
STS-{1-4,11-14}-{1-4}-{1,4}-{1}-{1-12}
STS-{1-4,11-14}-{1-4}-{1,4}-{1}-{1-3}
STS-{1-4,11-14}-{1-4}-{1,4}-{1}-{1-48}
STS-{1-4,11-14}-{1-4}-{1-192}
STS-{1-4,11-14}-{1-4}-{1-4}-{1}-ALL
STS-{1-4,11-14}-{1-4}-{1-4}-{1}-{1,4,7,13,16,19,25,28,31,43}
STS-{1-4,14-17}-{1-16}-{1-48}
STS-{1-4,14-17}-{1-4}-1
STS-{1-4,14-17}-{1-4}-ALL
STS-{1-4,14-17}-{1-4}-{1,4,7,10}
STS-{1-4,14-17}-{1-4}-{1,4,7}
STS-{1-4,14-17}-{1-4}-{1-3}
|
STS (continued)
|
STS-{1-4,14-17}-{1-8}-1
STS-{1-4,14-17}-{1-8}-ALL
STS-{1-4,14-17}-{1-8}-{1-3}
STS-{1-4}-1-1
STS-{1-4}-1-ALL
STS-{1-4}-1-{1,13,25,37}
STS-{1-4}-1-{1,4,7,10,-.,46}
STS-{1-4}-1-{1,4,7,10}
STS-{1-4}-1-{1,7,13,19,-,43}
STS-{1-4}-1-{1,7}
STS-{1-4}-1-{1-12}
STS-{1-4}-1-{1-48}
STS-{1-6,12-17}-1
STS-{1-6,12-17}-1-1
STS-{1-6,12-17}-1-ALL
STS-{1-6,12-17}-1-{1,13,25,37}
STS-{1-6,12-17}-1-{1,4,10,13,16,19,25,28,37,40}
STS-{1-6,12-17}-1-{1,4,7,10,13,16,19,22,25}
STS-{1-6,12-17}-1-{1,4,7,10-46}
STS-{1-6,12-17}-1-{1,4,7,10}
STS-{1-6,12-17}-1-{1,4,7,13,16,19,25,28,37,40,43}
STS-{1-6,12-17}-1-{1,4,7}
STS-{1-6,12-17}-1-{1,4}
STS-{1-6,12-17}-1-{1-12}
STS-{1-6,12-17}-1-{1-48}
STS-{1-6,12-17}-ALL
STS-{1-6,12-17}-{1-12}-1
STS-{1-6,12-17}-{1-24}-1
STS-{1-6,12-17}-{1-36}-1
STS-{1-6,12-17}-{1-4}-1
STS-{1-6,12-17}-{1-4}-ALL
STS-{1-6,12-17}-{1-4}-{1,4,7,10-46}
STS-{1-6,12-17}-{1-4}-{1,4,7}
|
STS (continued)
|
STS-{1-6,12-17}-{1-4}-{1,4}
STS-{1-6,12-17}-{1-4}-{1-12}
STS-{1-6,12-17}-{1-6}
STS-{2}-{1-2}-{1}-{1,4,7,10}
STS-{2}-{1-2}-{1}-{1,7}
STS-{2}-{1-2}-{1}-{1-12}
STS-{2}-{1-2}-{1}-{1-3}
STS-{2}-{1-2}-{1}-{1}
STS-{2}-{1-3}-{1}
STS-{2}-{1}
STS-{5,6,12,13}-1-1
STS-{5,6,12,13}-1-{1,13,25,37-180}
STS-{5,6,12,13}-1-{1,13,25,37}
STS-{5,6,12,13}-1-{1,4,7,10,13,16,19,22,25}
STS-{5,6,12,13}-1-{1,4,7,10-190}
STS-{5,6,12,13}-1-{1,4,7,10-46}
STS-{5,6,12,13}-1-{1,4,7,13,16,19,25,28,37,40,43}
STS-{5,6,12,13}-1-{1,49,97,145}
STS-{5,6,12,13}-1-{1-192}
STS-{5,6,12,13}-1-{1-48}
STS-{5,6}-1
STS-{5,6}-{1-4}-1
STS-{5-6}-ALL
VFAC-{1-6,12-17}-{0-1}
|
VT
|
ALL
VT1-{1-4,14-17}-{1-8}-{1-3}-{1-7}-{1-4}
VT1-{1-4}-1-{1-12}-{1-7}-{1-4}
VT1-{1-4}-1-{1-48}-{1-7}-{1-4}
VT1-{1-4}-{1-4}-{1-3}-{1-7}-{1-4}
VT1-{1-6,12-17}-1-{1-12}-{1-7}-{1-4}
VT1-{1-6,12-17}-1-{1-48}-{1-7}-{1-4}
VT1-{1-6,12-17}-1-{1-7}-{1-2}
VT1-{1-6,12-17}-{1-12}-1-{1-7}-{1-4}
VT1-{1-6,12-17}-{1-24}-1-{1-7}-{1-4}
VT1-{1-6,12-17}-{1-36}-1-{1-7}-{1-4}
VT1-{1-6,12-17}-{1-4}-{1-12}-{1-7}-{1-4}
VT1-{1-6,12-17}-{1-4}-{1-3}-{1-7}-{1-4}
VT1-{1-6,12-17}-{1-6}-{1-7}-{1-4}
VT1-{2}-{1-2}-{1}-{1-12}-{1-7}-{1-4}
VT1-{2}-{1-2}-{1}-{1-3}-{1-7}-{1-4}
VT1-{2}-{1-3}-{1}-{1-7}-{1-4}
VT1-{2}-{1}-{1-7}-{1-3}
VT1-{5,6,12,13}-1-{1-192}-{1-7}-{1-4}
VT1-{5,6,12,13}-1-{1-48}-{1-7}-{1-4}
VT1-{5-6}-1-{1-7}-{1-2}
VT1-{5-6}-1-{1-7}-{1-4}
VT2-{1-4,14-17}-{1-8}-{1-3}-{1-7}-{1-3}
VT2-{1-6,12-17}-1-{1-12}-{1-7}-{1-3}
VT2-{1-6,12-17}-1-{1-48}-{1-7}-{1-3}
VT2-{1-6,12-17}-{1-4}-{1-12}-{1-7}-{1-3}
VT2-{1-6,12-17}-{1-4}-{1-3}-{1-7}-{1-3}
VT2-{5,6,12,13}-1-{1-192}-{1-7}-{1-3}
VT2-{5,6,12,13}-1-{1-48}-{1-7}-{1-3}
|
4.5.11 DS1
(Cisco ONS 15454 only)
Used to access the DS-1 frame layer of the DS3XM. The format is DS1-[SLOT]-[DS3PORT]-[DS1PORT]
Table 4-26 DS1
Pattern
|
Description
|
ALL
|
The ALL AID applies to RTRV-DS1 and RTRV-ALM/COND-DS1 commands only to retrieve all DS1 facilities and DS1-level alarms/conditions on the NE
|
DS1-{1-6,12-17}-{1-12,13,15,17,19,21,23,25,27,29,31,33,35}-{1-28}
|
DS1 AIDs for DS3XM-12 (ONS 15454) STS48 Backplane Rate. Ports 1 to12 are always available, odd ports after 12 are available
|
DS1-{1-6,12-17}-{1-12,13,15,17,19,21,23}-{1-28}
|
DS1 AIDs for DS3XM-12 (ONS 15454) STS12 Backplane Rate. Ports 1 to 12 are always available, odd ports after 12 are available
|
DS1-{1-6,12-17}-{1-6}-{1-28}
|
DS1 AIDs for the DS3XM-6 card (ONS 15454)
|
4.5.12 ENV
The environmental AID for the AIC/AICI cards
Table 4-27 ENV
Pattern
|
Description
|
ALL
|
The ALL AID applies to retrieve-only commands: RTRV-ALM/COND-ENV, RTRV-ATTR-CONT and RTRV-ATTR-ENV
|
ENV-IN-ALL
|
Environmental AID for ALL Environmental alarms on the Cisco ONS 15454, 15327, 15600, 15310-CL
|
ONS 15454 Environmental AIDs
|
ENV-IN-{1-4}
|
Environmental AID for the AIC Card on the ONS 15454. "IN" is used for Environmental Alarms
|
ENV-IN-{1-20}
|
Environmental AID for the AICI Card on the ONS 15454. "IN" is used for Environmental Alarms
|
ENV-IN-{1-32}
|
Environmental AID for AICI Card Extensions on the ONS 15454. "IN" is used for Environmental Alarms
|
ENV-IN-{1-16}
|
Environmental AID on the ONS 15454. "IN" is used for Environmental Alarms
|
ENV-OUT-{1-4}
|
Environmental AID for the AIC/AICI Cards on the ONS 15454. "OUT" is used for Environmental Controls
|
ENV-OUT-{1-16}
|
Environmental AID for AICI Card Extensions on the ONS 15454. "OUT" is used for Environmental Controls
|
ONS 15327 Environmental AIDs
|
ENV-IN-{1-6}
|
Environmental AID for the ONS 15327. "IN" is used for Environmental Alarms
|
ENV-OUT-{1-2}
|
Environmental AID for the ONS 15327. "OUT" is used for Environmental Controls
|
ONS 15600 Environmental AIDs
|
ENV-IN-ALL
|
Environmental AID for ALL Environmental alarms on the Cisco ONS 15454, 15327, 15600, 15310-CL
|
ENV-OUT-{1-16}
|
Environmental AID for the ONS 15600. "OUT" is used for Environmental Controls
|
ENV-OUT-ALL
|
All Environmental Control Output contacts
|
ONS 15310-CL Environmental AIDs
|
ENV-IN-{1-3}
|
Environmental AID for the ONS 15310-CL. "IN" is used for Environmental Alarms
|
ENV-OUT-{1-2}
|
Environmental AID for the ONS 15310-CL. "OUT" is used for Environmental Controls
|
4.5.13 EQPT
Equipment AIDs are used to access specific cards.
In the ONS 15454, the OC48/OC192 cards can only use the high speed slots (Slot 5, Slot 6, Slot 12, Slot 13).
In the ONS 15327, Slots 1 to 4 are for I/O cards (Ethernet and Optical cards). Slots 5 and 6 are for the XTC cards, and Slots 7 and 8 are for the MIC cards.
In the ONS 15600, Slots 1 through 4 and Slots 11 through 14 are used for I/O cards. Slot 5 and 10 are reserved for the TSC card. Slots 6, 7, and Slots 8, 9 are reserved for the CXC/SSXC card.
Table 4-28 EQPT
Pattern
|
Description
|
AIP
|
The AID for the AIP. It is used for RTRV-INV output only (ONS 15454)
|
ALL
|
Only used for RTRV-INV, RTRV-EQPT, and RTRV-ALM/COND-EQPT commands. RTRV-INV returns all the inventory information for the NE. The ONS 15454 includes the I/O cards, controller cards, and the AIP, BP, and FAN. The ONS 15327 includes the I/O cards and controller cards. RTRV-EQPT with ALL AID returns EQPT information on all the slots. RTRV-ALM/COND-EQPT with ALL AID returns EQPT and PWR-A and PWR-B type of alarms/conditions
|
BIC-ALL
|
AIDs for the BIC (Backplane Interface Connector), BIC-A and BIC-B. These AIDs are valid only for the RTRV-ALM-EQPT and RTRV-COND-EQPT commands
|
BIC-{A,B}
|
AIDs for the BIC (Backplane Interface Connectors). These AIDs are valid only for the RTRV-ALM-EQPT and RTRV-COND-EQPT commands
|
BP
|
The AID for the backplane. It is used for RTRV-INV output only (ONS 15454 only)
|
FAN
|
The AID for the fan tray. It is used for RTRV-INV output only
|
PIM-{1-4,11-14}-ALL
|
Pluggable Interface Module. Applicable for RTRV-EQPT and RTRV-INV commands pertaining to the ONS 15600 ASAP Card only. Format is PIM-[SLOT]-[PIM]-[PPM]
|
PIM-{1-4,11-14}-{1-4}
|
Pluggable Interface Module. Applicable for ENT/ED/RTRV/DLT-EQPT and RTRV-INV commands pertaining to the ONS 15600 ASAP Card only. Format is PPM-[SLOT]-[PIM]-[PPM]
|
PPM-1-{1,2}
|
Pluggable Port Module AID for the ONS 15310-CL ML-100T-8/CE-100T-8 Card. Format is PPM-[SLOT]-[PPM]
|
PPM-2-{1,2}
|
PPM AID for the ONS 15310-CL. Format is PPM-[SLOT]-[PPM]
|
PPM-{1-4,11-14}-{1-4}-ALL
|
PPM. Applicable for the RTRV-EQPT and RTRV-INV commands pertaining to the ONS 15600 ASAP Card only. Format is PPM-[SLOT]-[PIM]-[PPM]
|
PPM-{1-4,11-14}-{1-4}-{1-4}
|
PPM. Applicable for the ENT/ED/RTRV/DLT-EQPT and RTRV-INV commands pertaining to the ONS 15600 ASAP Card only. Format is PPM-[SLOT]-[PIM]-[PPM]
|
PPM-{1-6,12-17}-{1-4}
|
PPM AID for DWDM MXP_2.5G_10G, TXP_MR_10G, TXP_MR_2.5G, TXPP_MR_2.5G, MXP_2.5G_10E, and TXP_MR_10E Cards. Format of AID is PPM-[SLOT]-[PPM]
|
PPM-{1-6,12-17}-{1-8}
|
PPM AID for the ONS 15454 MXP_MR_2.5G and MXPP_MR_2.5G Card. Format of AID is PPM-[SLOT]-[PPM]
|
PWR-ALL
|
AIDs for the Power Supply Sources. These AIDs are valid only for the RTRV-ALM-EQPT and RTRV-COND-EQPT commands.
|
PWR-{A,B}
|
AIDs for the Power Supply Sources. These AIDs are valid only for the RTRV-ALM-EQPT and RTRV-COND-EQPT commands.
|
SLOT-ALL
|
All of the NE equipment AIDs
|
SLOT-{1-14}
|
EQPT AID for the ONS 15600 where format is SLOT-[SLOT]
|
SLOT-{1-17}
|
EQPT AID for the ONS 15454 where format is SLOT-[SLOT]
|
SLOT-{1-2}
|
EQPT AID for the ONS 15310-CL where format is SLOT-[SLOT]
|
SLOT-{1-4,11-14}
|
ONS 15600 I/O Slots only
|
SLOT-{1-6,12-17}
|
Individual equipment AID of the I/O card units or slots for the ONS 15454 where format is SLOT-[SLOT]
|
SLOT-{1-8}
|
EQPT AID for ONS 15327 where format is SLOT-[SLOT]
|
4.5.14 FACILITY
Facilities AIDs are used to access specific ports. Applicable to Cisco ONS 15454, 15327, 15600, 15310-CL.
Note Because the ONS 15310-CL supports more than one type of facility per slot, the FAC-AID format is not supported. The format Tn-, EC1- , and OCn- is used instead.
ONS 15454, 15327, and 15600 Facility AID format:
•Format for Optical and EC1 Facilities Without PPM: FAC-[SLOT]-[PORT]
•Format for Optical Facilities With PPM: FAC-[SLOT]-[PPM]-[PORT]
•Format for Optical Facilities With PPM and PIM: FAC-[SLOT]-[PIM]-[PPM]-[PORT]
•Format for DS1-Flavored Electrical Facilities: FAC-[SLOT]-[PORT]
•Format for DS3-Flavored (Including DS3I) Electrical Facilities: FAC-[SLOT]-[PORT]
•Format for POS Ports: VFAC-[SLOT]-[PORT]
•Format for POS Port with PIM and PPM:VFAC-[SLOT]-[PIM]-[PPM]-[PORT]
ONS 15310-CL Facility AID format:
•Format for Optical Facilities Without PPM: OCn-[SLOT]-[PORT]
•Format for Optical Facilities With PPM: OCn-[SLOT]-[PPM]-[PORT]
•Format for EC1 Facilities: EC1-[SLOT]-[PORT]
•Format for DS1-Flavored Electrical Facilities: T1-[SLOT]-[PORT]
•Format for DS3-Flavored Electrical Facilities: T3-[SLOT]-[PORT]
•Format for POS Ports: VFAC-[SLOT]-[PORT]
•Format for FSTE Ethernet Facilities: FSTE-[SLOT]-[PORT]
Table 4-29 FACILITY
Pattern
|
Description
|
ALL
|
The ALL AID is applicable for RTRV-only commands (RTRV-rr type of commands), for example: RTRV-OC48 with ALL AID returns all OC48 facilities on the node. RTRV-T1 with ALL AID returns all T1 facilities on the node.
|
EC1-{2}-{1-3}
|
Facility AIDs for EC1 ports on the 15310-CL-CTX (ONS 15310-CL), where format is EC1-[SLOT]-[PORT]
|
FAC-{1-4,11-14}-ALL
|
Facility AID for all I/O Unit or Slot on the ONS 15600, where format is FAC-[SLOT]-ALL
|
FAC-{1-4,11-14}-{1-16}
|
Facility AIDs for the 16-Port OC48 (ONS 15600), where format is FAC-[SLOT]-[PORT]
|
FAC-{1-4,11-14}-{1-4}
|
Facility AID for the 4-Port OC192 (ONS 15600), where format is FAC-[SLOT]-[PORT]
|
FAC-{1-4,11-14}-{1-4}-{1-4}-{1}
|
Facility AID for the ASAP Card with PIM and PPM. Format is FAC-[SLOT]-[PIM]-[PPM]-[PORT]
|
FAC-{1-4,14-17}-{1-8}
|
Facilities for an OC3-8 card (ONS 15454) where the format is FAC-[SLOT]-[PORT]
|
FAC-{1-4}-1
|
Facility AIDs for OC12, OC48 (ONS 15327) where the format is FAC-[SLOT]-[PORT]
|
FAC-{1-4}-{1-4}
|
Facility AIDs for 4-Port OC3 (ONS 15327) where the format is FAC-[SLOT]-[PORT]
|
FAC-{1-6,12-17}-1
|
Facility AID for the 1 Client (CLNT) Port on a TXP_MR_10G, TXP_MR_2.5G, TXP_MR_2.5G or TXPP_MR_2.5G card (ONS 15454) where the format is FAC-[SLOT]-[PORT]
|
FAC-{1-6,12-17}-ALL
|
All the facilities of an I/O unit or slot (ONS 15454) where the format is FAC-[SLOT]-[ALL]
|
FAC-{1-6,12-17}-{0-11}
|
Facilities for the Ethernet Front-end ports on the ML100T-12 card. Ports are numbered starting with 0 (i.e. the first port is FAC-SLOT-0, second port is FAC-SLOT-1, ..., last port is FAC-SLOT-11 for ML100T-12 and first port is FAC-SLOT-0 and second port is FAC-SLOT-1 for ML1000-2) (ONS 15454). The format is FAC-[SLOT]-[PORT]
|
FAC-{1-6,12-17}-{0-1}
|
Facilities for the Ethernet Backend Ports on the ML1000-2 card. Ports are 0-based, (i.e the first port is FAC-SLOT-0 and the second port is FAC-SLOT-1) (ONS 15454). The format is FAC-[SLOT]-[PORT]
|
FAC-{1-6,12-17}-{1-12,14,16,18, 20,22,24,26,28,30,32,34,36}
|
Facility AIDs for the DS3XM-12 STS48 Backplane Rate where format is FAC-[SLOT]-[PORT]. Ports 1 through 12 are always available, but only even ports after 12 are available
|
FAC-{1-6,12-17}-{1-12,14,16,18, 20,22,24}
|
Facility AIDs for DS3XM-12 STS12 Backplane Rate where format is FAC-[SLOT]-[PORT]. Ports 1 through 12 are always available, but only even ports after 12 are available
|
FAC-{1-6,12-17}-{1-12}
|
Facilities AID for the EC1 and DS3 cards (ONS 15454) where format is FAC-[SLOT]-[PORT]
|
FAC-{1-6,12-17}-{1-4}
|
Facility AID for the four Client (CLNT) facilities on the MXP_2.5G_10G card. Facility AID for 4-Port G1000/FC_MR-4 Card. Facility AID for creating/editing cross-connects (STS1/VC3, STS3C/VC4, STS6C/VC4-2C, STS9C/VC4-3C, STS12C/VC4-4C, and STS24C/VC4-8C) for the 4-Port G1000/FC_MR-4 Card (ONS 15454) where format is FAC-[SLOT]-[PORT]
|
FAC-{1-6,12-17}-{1-6}
|
Facilities for the DS3XM card (ONS 15454) where format FAC-[SLOT]-[PORT]
|
FAC-{1-6,12-17}-{1}
|
Facility AID for the 1-Port OC12, OC48AS and OC3 in OSC-CSM cards. Facility AID for the client ports on the MXP/TXP and TXP_MR_2.5G cards (ONS 15454) where format is FAC-[SLOT]-[PORT]
|
FAC-{1-6}-ALL
|
Facility AIDs for I/O unit or slots (ONS 15327) where format is FAC-[SLOT]-[ALL]
|
FAC-{5,6,12,13}-{1}
|
Facility AID for the OC48/OC192 cards. The OC48/OC192 cards can only use the high speed slots (Slot 5, Slot 6, Slot 12, Slot 13) (ONS 15454) where format is FAC-[SLOT]-[PORT]
|
FAC-{5-6}-{1-28}
|
Facility AID for the T1 Ports on the XTC-28-3 (ONS 15327) where format is FAC-[SLOT]-[PORT]
|
FAC-{5-6}-{1-3}
|
Facility AIDs on the TR Ports in the XTC-28-3 (ONS 15327) where format is FAC-[SLOT]-[PORT]
|
FAC-{8,10}-{1}
|
Facility AID for the OSCM card. The OSCM cards can only use the XC slots (Slot-8, Slot-10) (ONS 15454) where format is FAC-[SLOT]-[PORT]
|
FSTE-{1}-{0-7}
|
Facility AIDs for front end ports on the ML-100T-8 card (ONS 15310-CL), when provisioned in L2L3 mode. Format is FSTE-[SLOT]-[PORT]. Port numbering is 0-based
|
FSTE-{1}-{1-8}
|
Facility AIDs for front end ports on the CE-100T-8 card (ONS 15310-CL), when provisioned in Mapper mode. Format is FSTE-[SLOT]-[PORT]. Port numbering is 1-based
|
OC12-{2}-{1-2}-{1}
|
Facility AIDs for OC12 ports on the 15310-CL-CTX (ONS 15310-CL) where format is OC12-[SLOT]-[PPM]-[PORT]
|
OC3-{2}-{1-2}-{1}
|
Facility AIDs for OC3 ports on the 15310-CL-CTX (ONS 15310-CL) where format is OC3-[SLOT]-[PPM]-[PORT]
|
T1-{2}-{1-21}
|
Facility AIDs for T1 ports on the 15310-CL-CTX (ONS 15310-CL) where format is T1-[SLOT]-[PORT]
|
T3-{2}-{1-3}
|
Facility AIDs for T3 ports on the 15310-CL-CTX (ONS 15310-CL) where format is T3-[SLOT]-[PORT]
|
VFAC-{1-4,11-14}-{1-4}-{1-4}-1
|
Facilities for the back end POS ports on the L1P_ETHERNET PORT on an ASAP Card. Applicable on the ONS15600 only. Format is VFAC-[SLOT]-[PIM]-[PPM]-[PORT]
|
VFAC-{1-6,12-17}-{0-1}
|
Facilities for the back end POS ports on the ML-Series card. Port numbering is 0-based (first POS port is VFAC-SLOT-0, second POS port is VFAC-SLOT-1). VC4, VC4-2C, VC4-3C, VC4-4C, VC4-8C for the ML1000 and ML100T Cards (ONS 15454). Format is VFAC-[SLOT]-[PORT]
|
VFAC-{1-6,12-17}-{1,2}
|
GFP facilities on the MXP-MR-2.5G and MXPP-MR-2.5G card
|
VFAC-{1-6,12-17}-{1,2}-{1,8}
|
GFP Client facilities for MXP-MR-2.5G and MXPP-MR-2.5G cards
|
VFAC-{1}-{0-1}
|
Facility AIDs for back end ports on the ML card (ONS 15310-CL), when provisioned in L2L3 mode. Format is VFAC-[SLOT]-[PORT]. Port numbering is 0-based
|
VFAC-{1}-{1-8}
|
Facility AIDs for back end ports on the ML card (ONS 15310-CL), when provisioned in L2L3 mode. Format is VFAC-[SLOT]-[PORT]. Port numbering is 1-based
|
4.5.15 IPADDR
IP Address
Table 4-30 IPADDR
Pattern
|
Description
|
111.222.333.444
|
Standard 4 Part IP Address Notation
|
ALL
|
ALL
|
4.5.16 LINE
(Cisco ONS 15454 only)
The LINE AID is used to access the Optical Transport Section (OTS) layer of optical network units. Applicable only to ONS 15454 AD-1B-xx.x, AD-4B-xx.x, AD-1C-xx.x, AD-2C-xx.x, AB-4C-xx.x, OSC-CSM, OSCM, OPT-BST, OPT-PRE, 4MD-xx.x, 32MUX-O and 32DMX-O cards. The format is LINE-[SLOT]-[PORT]-[DIRECTION].
Table 4-31 LINE
Values
|
Description
|
ALL
|
All of the OTSs of the NE. The ALL AID applies for retrieve-only commands
|
LINE-{1-6,12-17}-{1-2}-ALL
|
All the Lines in a OPT-PRE, OCS-CSM, AD-1B, AD-4B, AD-1C, AD-2C, AD-4C units
|
LINE-{1-6,12-17}-{1-2}-{RX,TX}
|
The receive/transmit Lines in a OPT-PRE, OCS-CSM, AD-1B, AD-4B, AD-1C, AD-2C, AD-4C units
|
LINE-{1-6,12-17}-{1-3}-ALL
|
All the Lines in a OPT-BST units
|
LINE-{1-6,12-17}-{1-3}-{RX,TX}
|
The receive/transmit Lines in a OPT-BST units
|
LINE-{8,10}-{1}-ALL
|
All the Lines in a OSCM units
|
LINE-{8,10}-{1}-{RX,TX}
|
The receive/transmit Lines in an OSCM units
|
4.5.17 LNKTERM
Link Termination AIDs that are used to access the termination points of a provisionable patchcord.
Table 4-32 LNKTERM
Pattern
|
Description
|
ALL
|
Indicates all the provisionable patchcord terminations on a node. Applicable only for the retrieve commands
|
LNKTERM-ALL
|
Indicates all the provisionable patchcord terminations on a node. Applicable only for the retrieve commands
|
LNKTERM-{1-65535}
|
Indicates a single provisionable patchcord termination point on a node. Where format is LNKTERM-
|
4.5.18 OPM
OPM AIDs represent the single wavelength inside an optical power monitoring object
Table 4-33 OPM
Values
|
Description
|
OPM-{1-5,12-16}--{1530.33,1531.12, 1531.90,1532.68,1534.25,1535.04, 1535.82,1536.61,1538.19,1538.98, 1539.77,1540.56,1542.14,1542.94, 1543.73,1544.53,1546.12,1546.92, 1547.72,1548.51,1550.12,1550.92, 1551.72,1552.52,1554.13,1554.94, 1555.75,1556.55,1558.17,1558.98, 1559.79,1560.61}
|
The second index is the slot where the 32-WSS unit is configured. The last index of the wavelength is the value of the wavelength as described in OPTICAL_WLEN
|
4.5.19 OSC
(Cisco ONS 15454 only)
OSC AIDs are used to access the OSC of the NE
Table 4-34 OSC
Values
|
Description
|
ALL
|
All of the OSCs of the NE. The ALL AID applies to the retrieve-only commands
|
OSC-RINGID
|
RINGID is a string of up to six characters, valid characters are [A-Z,0-9] (case insensitive)
|
4.5.20 PRSLOT
(Cisco ONS 15454 only)
Valid protection slots for the electrical cards
Table 4-35 PRSLOT
Pattern
|
Description
|
NULL
|
Indicates there is no protection group. Used when trying to delete a protection group.
|
SLOT-1
|
The No.1 slot of an NE
|
SLOT-3
|
The No.3 slot of an NE
|
SLOT-5
|
The No.5 slot of an NE
|
SLOT-13
|
The No.13 slot of an NE
|
SLOT-15
|
The No.15 slot of an NE
|
SLOT-17
|
The No.17 slot of an NE
|
4.5.21 RFILE
File transfer type. Applicable to ONS 15454, 15327, and 15310-CL.
Table 4-36 RFILE
Pattern
|
Description
|
RFILE-DB
|
Transferring the system database
|
RFILE-PKG
|
Transferring a software package
|
4.5.22 STS
SONET frame-level AID set
•STS AID Format for Optical and EC1 Facilities Without PPM: STS-[SLOT]-[PORT]-[STS]
•STS AID Format for Optical Facilities With PPM: STS-[SLOT]-[PPM]-[PORT]-[STS]
•STS AID Format for Optical Facilities With PIM and PPM: STS-[SLOT]-[PIM]-[PPM]-[PORT]-[STS]
•STS AID Format for DS1 Electrical Facilities: STS-[SLOT]-[STS]
•STS AID Format for DS3 (Except DS3I) Electrical Facilities: STS-[SLOT]-[PORT]-[STS]
•STS AID Format for DS3I Electrical Facilities: STS-[SLOT]-[STS]
•STS AID Format for G1000 Card GIGE Facilities: FAC-[SLOT]-[PORT]
Table 4-37 STS
Pattern
|
Description
|
ALL
|
The ALL AID applies to the RTRV-only commands: RTRV-STS with ALL AID retrieves all STS interfaces on the NE. RTRV-STS1 with ALL AID retrieves all STS1 interfaces on the NE. RTRV-STS3c with ALL AID retrieves all STS3c interfaces on the NE.
|
FAC-{1-4,11-14}-{1-4}-{1-4}-{1}
|
Dynamically allocated STSs of all widths for the GIGE port on an ASAP Card. Format is FAC-[SLOT]-[PIM]-[PPM]-[PORT]
|
FAC-{1-6,12-17}-{1-4}
|
Dynamically allocated STSs of all widths for the G1000-4 card (ONS 15454). Format is FAC-[SLOT]-[PORT]
|
STS-{1-4,11-14}-{1-16}-1
|
STS48c AID for 16-Port OC48 (ONS 15600). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{1-4,11-14}-{1-16}-ALL
|
All the STS of all path width on the 16-Port OC48 (ONS 15600). Format is STS-[SLOT]-[PORT]-ALL
|
STS-{1-4,11-14}-{1-16}-{1,13,25,37}
|
STS12C AID for 16-port OC48 (ONS 15600). Format is STS-[SLOT]-[PORT]-ALL
|
STS-{1-4,11-14}-{1-16}-{1,25}
|
STS24C AID for 16-Port OC48 (ONS 15600). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{1-4,11-14}-{1-16}-{1,4,7,10,-,46}
|
STS3c AID for 16-Port OC48 (ONS 15600). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{1-4,11-14}-{1-4}-1
|
STS192c AID for 4-Port OC192 (ONS 15600). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{1-4,11-14}-{1-4}-ALL
|
All the STS of all path width on 4-Port OC192 (ONS 15600). Format is STS-[SLOT]-[PORT]-ALL
|
STS-{1-4,11-14}-{1-4}-{1,13,25,37,-,181}
|
STS12c AID for 4-Port OC192 (ONS 15600). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{1-4,11-14}-{1-4}-{1,25,49,73,-,169}
|
STS24c AID for 4-Port OC192 (ONS 15600). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{1-4,11-14}-{1-4}-{1,4,7,10,-,190}
|
STS3c AID for 4-Port OC192 (ONS 15600). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{1-4,11-14}-{1-4}-{1,49,97,145}
|
STS48c AID for 4-Port OC192 (ONS 15600). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{1-4,11-14}-{1-4}-{1,4}-{1}
|
StS3c AID for the ASAP Card with OC3 PORT provisioned. STS12C AID for the ASAP Card with OC12 Port Provisioned. STS48C AID for the ASAP Card with OC48 Port Provisioned. Format of AID is STS-[SLOT]-[PIM]-[PPM]-[PORT]-[STS]
|
STS-{1-4,11-14}-{1-4}-{1,4}-{1}-{1,13,25,37}
|
STS12C AID for the ASAP Card with OC48 Port Provisioned. Format is STS-[SLOT]-[PIM]-[PPM]-[PORT]-[STS]
|
STS-{1-4,11-14}-{1-4}-{1,4}-{1}-{1,25}
|
STS24C AID for the ASAP Card with OC48 Port Provisioned. Format is STS-[SLOT]-[PIM]-[PPM]-[PORT]-[STS]
|
STS-{1-4,11-14}-{1-4}-{1,4}-{1}-{1,4,13,16, 25,28,37,40}
|
STS9C AID for the ASAP Card with OC48 Port Provisioned. Format is STS-[SLOT]-[PIM]-[PPM]-[PORT]-[STS]
|
STS-{1-4,11-14}-{1-4}-{1,4}-{1}-{1,4,7,10,13,16,19,22, 25,28,31,34,37,40,43,46}
|
STS3C AID for the ASAP Card with OC48 Port Provisioned. Format is STS-[SLOT]-[PIM]-[PPM]-[PORT]-[STS]
|
STS-{1-4,11-14}-{1-4}-{1,4}-{1}-{1,4,7}
|
STS6C AID for the ASAP Card with OC12 Port Provisioned. Format is STS-[SLOT]-[PIM]-[PPM]-[PORT]-[STS]
|
STS-{1-4,11-14}-{1-4}-{1,4}-{1}-{1,4}
|
STS9C AID for the ASAP Card with OC12 Port Provisioned. Format is STS-[SLOT]-[PIM]-[PPM]-[PORT]-[STS]
|
STS-{1-4,11-14}-{1-4}-{1,4}-{1}-{1-12}
|
STS1 AID for the ASAP Card with OC12 Port Provisioned. Format is STS-[SLOT]-[PIM]-[PPM]-[PORT]-[STS]
|
STS-{1-4,11-14}-{1-4}-{1,4}-{1}-{1-3}
|
STS1 AID for the ASAP Card with OC3 Port Provisioned. Format is STS-[SLOT]-[PIM]-[PPM]-[PORT]-[STS]
|
STS-{1-4,11-14}-{1-4}-{1,4}-{1}-{1-48}
|
STS1 AID for the ASAP Card with OC48 Port Provisioned. Format is STS-[SLOT]-[PIM]-[PPM]-[PORT]-[STS]
|
STS-{1-4,11-14}-{1-4}-{1-4}-{1}-ALL
|
STS1,STS3C,6C,9C,12C,24C,48C AID for the ASAP Card with OCN Port Provisioned. Format is STS-[SLOT]-[PIM]-[PPM]-[PORT]-[STS]
|
STS-{1-4,11-14}-{1-4}-{1-4}-{1}-{1,4,7,13,16,19,25,28, 31,43}
|
STS6C AID for the ASAP Card with OC48 Port Provisioned. Format is STS-[SLOT]-[PIM]-[PPM]-[PORT]-[STS]
|
STS-{1-4,14-17}-{1-16}-{1-48}
|
STS1 AID for 16-Port OC48 (ONS 15600). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{1-4,14-17}-{1-4}-1
|
STS12C aids for a 4-port OC12 card (ONS 15454). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{1-4,14-17}-{1-4}-ALL
|
All the STSs for a given 4-port OC12 card (OSN 15454). Format is STS-[SLOT]-[PORT]-ALL
|
STS-{1-4,14-17}-{1-4}-{1,4,7,10}
|
STS3C for the 4-port OC12 card (ONS 15454). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{1-4,14-17}-{1-4}-{1,4,7}
|
STS6C AIDs for a 4-port OC12 (ONS 15454). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{1-4,14-17}-{1-4}-{1-3}
|
STS1 AID for the 4-port OC3 card (ONS 15454). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{1-4,14-17}-{1-8}-1
|
STS3C for the 8-port OC3 card (ONS 15454). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{1-4,14-17}-{1-8}-ALL
|
All the STSs for a given 8-port OC3 card (ONS 15454). Format is STS-[SLOT]-[PORT]-ALL
|
STS-{1-4,14-17}-{1-8}-{1-3}
|
STS1 AID for the 8-port OC3 card (ONS 15454). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{1-4}-1-1
|
STS48c AID for 1-Port OC48 (ONS 15327). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{1-4}-1-ALL
|
STS ALL AID for 1-Port Cards (ONS 15327). Format is STS-[SLOT]-ALL
|
STS-{1-4}-1-{1,13,25,37}
|
STS12c AID for 1-Port OC48 (ONS 15327). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{1-4}-1-{1,4,7,10,-.,46}
|
STS3c AID for 1-Port OC48 (ONS 15327). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{1-4}-1-{1,4,7,10}
|
STS3c AID for 4-Port OC3 and 1-Port OC12 (ONS 15327). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{1-4}-1-{1,7,13,19,-,43}
|
STS6c AID for 1-Port OC48 (ONS 15327). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{1-4}-1-{1,7}
|
STS6c AID for 1-Port OC12 (ONS 15327). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{1-4}-1-{1-12}
|
STS1 AID for 4-Port OC3, 1-Port OC12 (ONS 15327). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{1-4}-1-{1-48}
|
STS1 AID for 1-Port OC48 (ONS 15327). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{1-6,12-17}-1
|
STS1 AID for a DS1 card (ONS 15454). Format is STS-[SLOT]-[STS]. There is only 1 STS for the DS1 card
|
STS-{1-6,12-17}-1-1
|
STS12C AID for a 1-port OC12 card STS48C AID for an OC48AS card (ONS 15454). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{1-6,12-17}-1-ALL
|
All the STSs of an STS bandwidth on a single port optical card (ONS 15454). Format is STS-[SLOT]-[PORT]-ALL
|
STS-{1-6,12-17}-1-{1,13,25,37}
|
STS12C AIDs for an OC48AS card (ONS 15454). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{1-6,12-17}-{1,4,10,13,16,19,25,28,37,40}
|
STS9C AID for an OC48AS card (ONS 15454). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{1-6,12-17}-1-{1,4,7,10,13,16,19,22,25}
|
STS24C AID for an OC48AS card (ONS 15454). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{1-6,12-17}-1-{1,4,7,10-46}
|
STS3C AID for an OC48AS card (ONS 15454). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{1-6,12-17}-1-{1,4,7,10}
|
STS3C for a 1-port OC12 card (ONS 15454). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{1-6,12-17}-1-{1,4,7,13,16,19,25,28,37,40,43}
|
STS6C AID for an OC48AS card (ONS 15454). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{1-6,12-17}-1-{1,4,7}
|
STS6C AID for an OC12 card (ONS 15454). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{1-6,12-17}-1-{1,4}
|
STS9C AID for a 1-port OC12 card (ONS 15454). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{1-6,12-17}-1-{1-12}
|
STS1 AID for a 1-port OC12 card (ONS 15454). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{1-6,12-17}-1-{1-48}
|
STS1 AID for an OC48AS card (ONS 15454). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{1-6,12-17}-ALL
|
STS ALL AID for the card in the given slot (ONS 15454). Format is STS-[SLOT]-[ALL]
|
STS-{1-6,12-17}-{1-12}-1
|
STS1 AID for EC1 and DS3 cards (ONS 15454). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{1-6,12-17}-{1-24}-1
|
STS1 AIDs for the DS3XM-12 STS12 backplane rate cards. Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{1-6,12-17}-{1-36}-1
|
STS1 AIDs for the DS3XM-12 STS48 backplane rate cards. Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{1-6,12-17}-{1-4}-1
|
STS3C AID for a 4-port OC3 card (ONS 15454). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{1-6,12-17}-{1-4}-ALL
|
All the STSs for a 4-port OC3 card (ONS 15454). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{1-6,12-17}-{1-4}-{1,4,7,10-46}
|
Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{1-6,12-17}-{1-4}-{1,4,7}
|
STS6c AID for 4-Port OC12 (ONS 15454). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{1-6,12-17}-{1-4}-{1,4}
|
STS9C AID for a 4-port OC12 card (ONS 15454). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{1-6,12-17}-{1-4}-{1-12}
|
STS1 AID for a 4-port OC12 card (ONS 15454). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{1-6,12-17}-{1-6}
|
STS1 AID for a DS3XM card (ONS 15454). Format is STS-[SLOT]-[STS]
|
STS-{2}-{1-2}-{1}-{1,4,7,10}
|
STS3c AID for the OC12 port (ONS 15310-CL). Format is STS-[SLOT]-[PPM]-[PORT]-[STS]
|
STS-{2}-{1-2}-{1}-{1,7}
|
STS6c AID for the OC12 port (ONS 15310-CL). Format is STS-[SLOT]-[PPM]-[PORT]-[STS]
|
STS-{2}-{1-2}-{1}-{1-12}
|
STS1 AID for the OC12 port (ONS 15310-CL). Format is STS-[SLOT]-[PPM]-[PORT]-[STS]
|
STS-{2}-{1-2}-{1}-{1-3}
|
STS1 AID for the OC3 port. Format is STS-[SLOT]-[PPM]-[PORT]-[STS]
|
STS-{2}-{1-2}-{1}-{1}
|
STS3c AID for the OC3 port, or STS9C AID for the OC12 port, or STS12c AID for the OC12 port (ONS 15310-CL). Format is STS-[SLOT]-[PPM]-[PORT]-[STS]
|
STS-{2}-{1-3}-{1}
|
STS1 AID for the 15310-CL-CTX T3 ports (ONS 15310-CL). Format is STS-[SLOT]-[PORT]-[STS]. The AIDs are port based and presented as 1 STS per port
|
STS-{2}-{1}
|
STS1 AID for the 15310-CL-CTX T1 port (ONS 15310-CL). Format is STS-[SLOT]-[STS]. There is only 1 STS for the WBE ports on the 15310-CL-CTX card
|
STS-{5,6,12,13}-1-1
|
STS48C AID for an OC48 card STS192 AID for an OC192 card (ONS 15454). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{5,6,12,13}-1-{1,13,25,37-180}
|
STS12C AID for an OC192 card (ONS 15454). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{5,6,12,13}-1-{1,13,25,37}
|
STS12C AIDs for an OC48 card (ONS 15454). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{5,6,12,13}-1-{1,4,7,10,13,16,19,22,25}
|
STS24C AID for an OC48 card (ONS 15454). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{5,6,12,13}-1-{1,4,7,10-190}
|
STS3C for an OC192 card (ONS 15454). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{5,6,12,13}-1-{1,4,7,10-46}
|
STS3C AID for an OC48 card (ONS 15454). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{5,6,12,13}-1-{1,4,7,13,16,19,25,28,37,40,43}
|
STS6C AID for an OC48 card (ONS 15454). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{5,6,12,13}-1-{1,49,97,145}
|
STS48C AID for an OC192 card (ONS 15454). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{5,6,12,13}-1-{1-192}
|
STS1 AID for an OC192 card (ONS 15454). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{5,6,12,13}-1-{1-48}
|
STS1 AID for an OC48 card (ONS 15454). Format is STS-[SLOT]-[PORT]-[STS]
|
STS-{5,6}-1
|
STS1 AID for XTC-14, XTC-28-3 for the T1 Port (ONS 15327). Format is STS-[SLOT]-[STS]. There is only 1 STS for the T1 ports
|
STS-{5,6}-{1-4}-1
|
STS1 on a DS3 port on the 327 XTC-28 card
|
STS-{5-6}-ALL
|
STS ALL AID for the T1 and T3 Ports within the XTC-14 and XTC-28-3 (ONS 15327). Format is STS-[SLOT]-ALL
|
VFAC-{1-6,12-17}-{0-1}
|
Virtual facility AIDs for the ML-Series cards back end POS ports. Both the ML1000-2 and ML100T-12 have two POS ports and are 0-based (ONS 15454). Format is VFAC-[SLOT]-[PORT]
|
4.5.23 SYN
Synchronization AIDs
Table 4-38 SYN
Pattern
|
Description
|
SYNC-NE
|
NE sync AID
|
4.5.24 SYN_SRC
Synchronization source
Table 4-39 SYN_SRC
Pattern
|
Description
|
BITS-1
|
Sync source is BITS-1. Format is BITS-[PORT] (ONS 15454, 15327, 15600, 15310-CL)
|
BITS-2
|
Sync source is BITS-2. Format is BITS-[PORT] (ONS 15454, 15327, 15600)
|
FAC-{1-4,11-14}-{1-16}
|
Sync Source is 16-Port OC48 (ONS 15600). Format is FAC-[SLOT]-[PORT]
|
FAC-{1-4,11-14}-{1-4}
|
Sync source is 4-Port OC192. Format is FAC-[SLOT]-[PORT]
|
FAC-{1-4}-1
|
Sync Source is the Optical Card (1-Port OC12, OC48) facility in ONS 15327. Format is FAC-[SLOT]-[PORT]
|
FAC-{1-4}-{1-4}
|
Sync Source is the Optical Card (4-Port OC3) facility in ONS 15327. Format is FAC-[SLOT]-[PORT]
|
FAC-{1-6,12-17}-{1-4}
|
Sync source is the optical card (four-port OC3 and four-port OC12) facility in ONS 15454. Format is FAC-[SLOT]-[PORT]
|
FAC-{1-6,12-17}-{1}
|
Sync source is the optical card (one-port OC12 and OC48AS) facility in ONS 15454. Format is FAC-[SLOT]-[PORT]
|
FAC-{5,6,12,13}-{1}
|
Sync source is the optical card (OC48,OC192) facility. Format is FAC-[SLOT]-[PORT]
|
INTERNAL
|
Set the SYN_SRC to be the system default value. The "Internal" value of the SYN_SRC is only applied for the SYNC-NE AID on the ED-SYNCN command
|
NONE
|
Set the SYNC_SRC value to the default value for BITS-OUT. The "NONE" value of SYNC_SRC only applies to the BITS-1 and BITS-2 AID of the ED-SYNCN command
|
OC12-{2}-{1-2}-{1}
|
Sync source is the OC12 facility (ONS 15310-CL). Format is OC12-[SLOT]-[PPM]-[PORT]
|
OC3-{2}-{1-2}-{1}
|
Sync source is the OC3 facility (ONS 15310-CL). Format is OC3-[SLOT]-[PPM]-[PORT]
|
SYNC-NE
|
SYNC-NE source. It is only used in the alarm report or alarm retrieve commands.
|
T1-{2}-{1-21}
|
Sync source is the T1 facility (ONS 15310-CL). Format is T1-[SLOT]-[PORT]
|
4.5.25 SYNC_REF
Synchronization AIDs
ONS 15454 Facility AID format for line timing:
•Format for Optical Facilities Without PPM: FAC-[SLOT]-[PORT]
•Format for Optical Facilities With PPM: FAC-[slot]-[PPM]-[PORT]
ONS 15600 Facility AID format for line timing:
•Format for Optical Without PPM: FAC-[SLOT]-[PORT]
•Format for Optical Facilities With PPM: FAC-[SLOT]-[PPM]-[PORT]
•Format for Optical Facilities With PPM and PIM: FAC-[SLOT]-[PIM]-[PPM]-[PORT]
ONS 15310-CL Facility AID format for line timing:
•Format for Optical Facilities With PPM: OCn-[SLOT]-[PPM]-[PORT] where n={3,12}
•Format for DS1-Flavored Electrical Facilities: T1-[SLOT]-[PORT]
Table 4-40 SYNC_REF
Pattern
|
Description
|
ALL
|
Equivalent to a combination of SYNC-ALL, BITS-1 and BITS-2. This AID is valid only for the commands RTRV-SYNCN, RTRV-ALM-SYNCN and RTRV-COND-SYNCN
|
SYNC-ALL
|
All synchronization references
|
SYNC-NE
|
NE sync AID
|
SYNC-{BITS1,BITS2}
|
BITS1 and BITS2 sync AIDs (not supported on the ONS 15310-CL)
|
4.5.26 SYNCSW
New synchronization reference that will be used
Table 4-41 SYNCSW
Pattern
|
Description
|
INT
|
Internal clock. The "INT" value of the syncsw is only applied for the SYNC-NE AID on the OPR-SYNCSW command.
|
PRI
|
Primary timing reference
|
SEC
|
Secondary timing reference
|
THIRD
|
Third timing reference
|
4.5.27 UDC
(Cisco ONS 15454 only)
UDC AIDs for F-UDC and DCC-UDC channels on the AICI card. Applicable to ONS 15454. Applicable to ONS 15310-CL (F-UDC only).
Table 4-42 UDC
Pattern
|
Description
|
ALL
|
ALL AID is applicable to RTRV-only commands, for example: RTRV-ALM/COND-UDCF and RTRV-ALM/COND-UDCDCC. It corresponds to a superset of F-UDC and DCC-UDC AIDs
|
UDC-{F,DCC}-{A,B}
|
F-UDC and DCC-UDC AIDs for A and B channels
|
4.5.28 VT
Virtual tributary. Applicable to ONS 15454 and 15327.
•VT1 AID Format for Optical and EC1 Facilities Without PPM: VT1-[SLOT]-[PORT]-[STS]-[VTG]-[VTN]
•VT1 AID Format for Optical Facilities With PPM: VT1-[SLOT]-[PPM]-[PORT]-[STS]-[VTG]-[VTN]
•VT1 AID Format for DS1 Electrical Facilities: VT1-[SLOT]-[STS]-[VTG]-[VTN]
•VT1 AID Format for DS3 Electrical Facilities: VT1-[SLOT]-[PORT]-[STS]-[VTG]-[VTN]
Table 4-43 VT
Pattern
|
Description
|
ALL
|
The ALL AID applies to RTRV-only commands; for example, RTRV-VT and RTRV-VT1 with ALL AID returns all VT1 interfaces on the node
|
VT1-{1-4,14-17}-{1-8}-{1-3}-{1-7}-{1-4}
|
8-port OC3 card (ONS 15454)
|
VT1-{1-4}-1-{1-12}-{1-7}-{1-4}
|
VT AIDs for 1-Port OC12 (ONS 15327)
|
VT1-{1-4}-1-{1-48}-{1-7}-{1-4}
|
VT AIDs for 1-Port OC48 (ONS 15327)
|
VT1-{1-4}-{1-4}-{1-3}-{1-7}-{1-4}
|
VT AIDs for 4-Port OC3 (ONS 15327)
|
VT1-{1-6,12-17}-1-{1-12}-{1-7}-{1-4}
|
1-port OC12 card (ONS 15454)
|
VT1-{1-6,12-17}-1-{1-48}-{1-7}-{1-4}
|
OC48AS card (ONS 15454)
|
VT1-{1-6,12-17}-1-{1-7}-{1-2}
|
DS1 card (ONS 15454)
|
VT1-{1-6,12-17}-{1-12}-1-{1-7}-{1-4}
|
EC1 card (ONS 15454)
|
VT1-{1-6,12-17}-{1-24}-1-{1-7}-{1-4}
|
VT1.5 AIDs for DS3XM-12 STS12 backplane rate cards
|
VT1-{1-6,12-17}-{1-36}-1-{1-7}-{1-4}
|
VT1.5 AIDs for DS3XM-12 STS48 backplane rate cards
|
VT1-{1-6,12-17}-{1-4}-{1-12}-{1-7}-{1-4}
|
4-port OC12 card (ONS 15454)
|
VT1-{1-6,12-17}-{1-4}-{1-3}-{1-7}-{1-4}
|
4-port OC3 card (ONS 15454)
|
VT1-{1-6,12-17}-{1-6}-{1-7}-{1-4}
|
DS3XM-6 card (ONS 15454)
|
VT1-{2}-{1-2}-{1}-{1-12}-{1-7}-{1-4}
|
VT1 AIDs for OC3 Port on a 15310-CL-CTX card (ONS 15310-CL)
|
VT1-{2}-{1-2}-{1}-{1-3}-{1-7}-{1-4}
|
VT1 AIDs for OC3 Port on a 15310-CL-CTX card (ONS 15310-CL)
|
VT1-{2}-{1-3}-{1}-{1-7}-{1-4}
|
VT1 AIDs for BBE Port on a 15310-CL-CTX card (ONS 15310-CL). The AIDs are port based and presented as 1 STS per port. VTs are supported only for EC1 ports
|
VT1-{2}-{1}-{1-7}-{1-3}
|
VT1 AIDs for T1 (WBE) Port on a 15310-CL-CTX card (ONS 15310-CL). There is only 1 STS for the WBE ports on the 15310-CL-CTX card. There are 7 VT groups that each have 3 VTs within
|
VT1-{5,6,12,13}-1-{1-192}-{1-7}-{1-4}
|
OC192 Card (ONS 15454)
|
VT1-{5,6,12,13}-1-{1-48}-{1-7}-{1-4}
|
OC48 Card (ONS 15454)
|
VT1-{5-6}-1-{1-7}-{1-2}
|
VT AIDs for T1 Port within XTC-14 (ONS 15327). There is only 1 STS for the T1 ports within the XTC-14 card
|
VT1-{5-6}-1-{1-7}-{1-4}
|
VT AID for T1 Port with XTC-28-3 (ONS 15327). There is only 1 STS for the T1 ports within the XTC-28 card
|
VT2-{1-4,14-17}-{1-8}-{1-3}-{1-7}-{1-3}
|
8-port OC3 card (ONS 15454)
|
VT2-{1-6,12-17}-1-{1-12}-{1-7}-{1-3}
|
1-port OC12 card (ONS 15454)
|
VT2-{1-6,12-17}-1-{1-48}-{1-7}-{1-3}
|
OC48AS card (ONS 15454)
|
VT2-{1-6,12-17}-{1-4}-{1-12}-{1-7}-{1-3}
|
4-port OC12 card (ONS 15454)
|
VT2-{1-6,12-17}-{1-4}-{1-3}-{1-7}-{1-3}
|
4-port OC3 card (ONS 15454)
|
VT2-{5,6,12,13}-1-{1-192}-{1-7}-{1-3}
|
OC192 Card (ONS 15454)
|
VT2-{5,6,12,13}-1-{1-48}-{1-7}-{1-3}
|
OC48 card (ONS 15454)
|
4.5.29 WDMANS
(Cisco ONS 15454 only)
This AID is used to access the AONS application of the NE.
Table 4-44 WDMANS
Pattern
|
Description
|
AONS-{E,W}
|
Automatic Optical Node Setup identifier (is per ring direction based)
|
WDMANS-{E,W}
|
Automatic Optical Node Setup identifier (is per ring direction based)
|
4.5.30 WLEN
(Cisco ONS 15454 only)
This AID represents the single wavelength inside an external facility. If the facility is of type OTS (line) the wavelengths contained are all the available in the node: currently 32. If the facility is of type OCH (CHAN) the wavelength is just one and it is the same of the correspondent wavelength customized for that channel.
Table 4-45 WLEN
Pattern
|
Description
|
WLEN-{E,W}-{ADD,DROP,EXP}-{1530.33,1531.12,1531.90, 1532.68,1534.25,1535.04,1535.82,1536.61,1538.19,1538.98,1539.77, 1540.56,1542.14,1542.94,1543.73,1544.53,1546.12,1546.92,,1547.72, 1548.51,1550.12,1550.92,1551.72,1552.52,1554.13,1554.94, 1555.75,1556.55,1558.17,1558.98,1559.79,1560.61}
|
Wavelength identifier
|
4.6 Parameter Types
This section provides a description of all message parameter types defined for the TL1 messages used in the ONS SONET 15454, 15327, 15310-CL, and 15600. Individual parameters are listed within each command description in Chapter 3, "TL1 Command Descriptions" .
4.6.1 ATAG Description
The autonomous message tag (ATAG) is used for message sequencing. There are four streams of autonomous messages and each stream corresponds to a sequence. The sequence numbers increment by one for each autonomous message within that stream. The format and range of ATAG differs for each stream. The four streams are:
1. Alarmed events:
These include REPT ALM and REPT EVT (except REPT EVT SESSION) messages as well as the REPT SW autonomous message.
ATAG Format: x.y
where
x - sequence number of this alarmed event. This is an integer in the range of 0-9999.
y - sequence number of the previous alarmed event which is related to this alarmed event. This is an integer in the range of 0-9999.
If there is no such previous related event, then y will be the same as x. For example, the first time an alarm is raised you will receive the autonomous message:
TID-000 1998-06-20 14:30:00
* 1346.1346 REPT ALM T1
"FAC-1-1:MN,LOS,NSA,,,,:\"Loss Of Signal\",DS1-14"
;
When this alarmed event/condition is cleared, you will receive the autonomous message:
TID-000 1998-06-20 14:31:00
A 1349.1346 REPT ALM T1
"FAC-1-1:CL,LOS,NSA,,,,:\"Loss Of Signal\",DS1-14"
;
2. Database change messages:
The REPT DBCHG message falls into this category.
ATAG Format: x
where:
x - sequence number of the database change update message. This is an integer in the range of 0-9999. For example:
TID-000 1998-06-20 14:30:00
A 96 REPT DBCHG
"TIME=18-01-05,DATE=1970-01-01,SOURCE=2,USERID=CISCO15,
DBCHGSEQ=96:ENT-EQPT:SLOT-3"
;
Note The ATAG is the same as the DBCHGSEQ field in the REPT DBCHG output.
3. PM Reports:
The REPT PM messages fall into this category.
ATAG format: x
where:
x - sequence number of the PM report. This is an integer in the range of 0-9999. For example:
TID-000 1998-06-20 14:30:00
A5 REPT PM DS1
"FAC-3-1:CVL,10,PRTL,NEND,BTH,15-MIN,05-25,14-46"
;
This sequence number is global across all existing PM schedules.
4. Autonomous messages specific to a TL1 session. These messages are usually related to the security aspect of the TL1 session. Only the autonomous messages REPT EVT SESSION and CAN fall under this category. This is an integer in the range 0-9999.
For example:
TID-000 1998-06-20 14:30:00
A 1 CANC
"User"
;
4.6.2 CTAG Description
The correlation tag (CTAG) is included in each command by the user and is repeated by the
NE in the response to allow the user to associate the command and response messages. The valid values for a CTAG are strings of up to 6 characters comprised of identifiers (alphanumeric, beginning with a letter) or non-zero decimal numbers (a string of decimal digits with an optional non-trailing ".").
A zero in the response field is valid when indicating an error; for example, issuing a semi-colon by itself results in:
TID-000 1998-06-20 14:30:00
M 0 DENY IISP
/* Input, Garbage */
;
4.6.3 TID Description
The TID is the name of the NE where the command is addressed. TID is the Telcordia name for the system.
4.6.4 Parameter Notes
1. If a parameter is set to a value that is inconsistent with something already in the database, and that value is not changed to a consistent value then the command will be denied.
2. If a parameter is set to a value that is consistent with what is already in the database, but another parameter in the same command is incompatible, then the command will be denied.
3. The correct way to issue a command where parameters may be in conflict is to:
a. First issue that command and change all relevant parameters to compatible values,
b. Then issue the command again to change the target values.
For example, OC-N is syncmsg=y, to change SDH to y, ED-OCN needs to be called to set syncmsg=N, then called again to set SDH=y.
4. The attribute defaults have also been presented under RTRV commands, and they can be retrieved only if the RTRV commands follow the card/entity original provision.
5. The default for an optional field of an ED command is either the provisioned default value or the last provisioned value in the previous ED command.