cc/td/doc/product/ong/15400/r50docs
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table Of Contents

Storage Access Networking Cards

6.1  FC_MR-4 Card Overview

6.1.1  FC_MR-4 Card-Level Indicators

6.1.2  FC_MR-4 Port-Level Indicators

6.1.3  FC_MR-4 Compatibility

6.2  FC_MR-4 Card Modes

6.2.1  Line-Rate Card Mode

6.2.2  Enhanced Card Mode

6.2.3  Distance Extension (Enhanced Mode Only)

6.2.4  Interoperability Features (Enhanced Mode Only)

6.2.5  Link Integrity

6.2.6  Link Recovery

6.3  FC_MR-4 Card Application


Storage Access Networking Cards



Note The terms "Unidirectional Path Switched Ring" and "UPSR" may appear in Cisco literature. These terms do not refer to using Cisco ONS 15xxx products in a unidirectional path switched ring configuration. Rather, these terms, as well as "Path Protected Mesh Network" and "PPMN," refer generally to Cisco's path protection feature, which may be used in any topological network configuration. Cisco does not recommend using its path protection feature in any particular topological network configuration.


The FC_MR-4(Fibre Channel Multirate 4-port) card is a 1.0625- or 2.125-Gbps Fibre Channel/Fiber Connectivity (FICON) card that integrates non-SONET framed protocols into a SONET time-division multiplexing (TDM) platform through virtually concatenated payloads. For installation and step-by-step circuit configuration procedures, refer to the Cisco ONS 15454 Procedure Guide.

Chapter topics include:

FC_MR-4 Card Overview

FC_MR-4 Card Modes

FC_MR-4 Card Application

6.1  FC_MR-4 Card Overview

The FC_MR-4 card uses pluggable Gigabit Interface Converters (GBICs) to transport non-SONET/SDH-framed, block-coded protocols over SONET/SDH. The FC_MR-4 enables four client Fibre Channel (FC) ports to be transported over SONET/SDH, encapsulating the frames using the ITU-T Generic Framing Protocol (GFP) format and mapping them into either T1X1 G.707-based Virtual Concatenated (VCAT) payloads or standard contiguously concatenated SONET/SDH payloads. The FC_MR-4 card has the following features:

Four FICON ports operating at 1 Gbps or 2 Gbps

All four ports can be operational at any time due to subrate support

Advanced Distance Extension capability (buffer-to-buffer credit spoofing)

Pluggable GBIC optics

Dual rate (1G/2G): MM (550 m) and SM (10 km)

Single rate (1G): SX (550 m) and LX (10 km)

SONET/SDH support

Four 1.0625 Gbps FC channels can be mapped into SONET/SDH containers as small as STS1/VC3 (subrate), with a minimum of STS-24c/VC4-8c for full rate, and as large as STS48c/VC4-24c.

Four 2.125 Gbps FC channels can be mapped into SONET/SDH containers as small as STS1/VC3 (subrate), with a minimum of STS48c/VC4-24c for full rate, and as large as STS48c/VC4-24c.

Frame encapsulation: ITU-T G.7041 Generic Framing Procedure-Transparent (GFP-T)

High-order SONET/SDH virtual concatenation support (STS1-xv/VC-3 and STS3c-xv/VC-4)

Figure 6-1 shows the FC_MR-4 faceplate and block diagram.

Figure 6-1 FC_MR-4 Faceplate and Block Diagram

6.1.1  FC_MR-4 Card-Level Indicators

Table 6-1 describes the two card-level LEDs on the FC_MR-4 card.

Table 6-1 FC_MR-4 Card-Level Indicators  

Card-Level Indicators
Description
Red FAIL LED

The red FAIL LED indicates that the card's processor is not ready. Replace the card if the red FAIL LED persists.

Green ACT LED

If the ACTV/STBY LED is green, the card is operational and ready to carry traffic.

Amber ACT LED

If the ACTV/STBY LED is amber, the card is rebooting.


6.1.2  FC_MR-4 Port-Level Indicators

Each FC_MR-4 port has a corresponding ACT/LNK LED. The ACT/LNK LED is solid green if the port is available to carry traffic, is provisioned as in-service, and in the active mode. The ACT/LNK LED is flashing green if the port is carrying traffic. The ACT/LNK LED is steady amber if the port is not enabled and the link is connected, or if the port is enabled and the link is connected but there is an SONET/SDH transport error. The ACT/LNK LED is unlit if there is no link.

You can find the status of the card ports using the LCD screen on the ONS 15454 SDH fan-tray assembly. Use the LCD to view the status of any port or card slot; the screen displays the number and severity of alarms for a given port or slot. Refer to the Cisco ONS 15454 Troubleshooting Guide for a complete description of the alarm messages.

6.1.3  FC_MR-4 Compatibility

The FC_MR-4 cards can be installed in Slots 1 to 6 and 12 to 17 when used with XCVT and XC10G cards. The card can be provisioned as part of any valid ONS 15454 SONET/SDH network topology, such as a path protection, bidirectional line switched ring (BLSR), or linear network topologies. The FC_MR-4 card is compatible with Software R4.6 and greater.

6.2  FC_MR-4 Card Modes

The FC_MR-4 card can operate in two different modes:

Line Rate mode. This mode is backward compatible with the Software Release 4.6 Line Rate mod.

Enhanced mode. This mode supports subrate, distance extension, and other enhancements

The FC_MR-4 card reboots when a card mode changes (a traffic hit results). The FPGA running on the card upgrades to the required image. However, the FPGA image in the card's flash is not modified.

6.2.1  Line-Rate Card Mode

The mapping for the line-rate card mode is summarized here.

1 Gbps Fibre Channel/FICON is mapped into:

SONET CCAT: STS24c, STS48c

SONET VCAT: STS3c-8v, STS1c-24v

SDH CCAT: VC4-8c, VC4-16c

SDH VCAT: VC4-8v

2 Gbps Fibre Channel/FICON is mapped into:

SONET CCAT: STS48c

SONET VCAT: STS3c-16v, STS1c-48v

SDH CCAT: VC4-16c

SDH VCAT: VC4-16v

6.2.2  Enhanced Card Mode

The features available in enhanced card mode are given in this section.

6.2.2.1  Mapping

1 Gbps Fibre Channel/FICON is mapped into:

SONET CCAT: STS1c, STS3c, STS6c, STS9c, STS12c, STS18c, STS24c, STS48c

SONET VCAT: STS3c-Nv (N is 1 to 8), STS1c-Nv (N is 1 to 24)

SDH CCAT: VC4-1c, VC4-2c, VC4-3c, VC4-4c, VC4-6c, VC4-8c, VC4-16c

SDH VCAT: VC4-Nv (N is 1 to 8)

2 Gbps Fibre Channel/FICON is mapped into:

SONET CCAT: STS1c, STS3c, STS6c, STS9c, STS12c, STS18c, STS24c, STS36c, STS48c

SONET VCAT: STS3c-Nv (N is 1 to 16), STS1c-Nv (N is 1 to 48)

SDH CCAT: VC4-1c, VC4-2c, VC4-3c, VC4-4c, VC4-6c, VC4-8c, VC4-12c, VC4-16c

SDH VCAT: VC4-16v (N is 1 to 16)

6.2.2.2  SW -LCAS

Virtual Concatenation Group (VCG) is reconfigurable with the software link capacity adjustment scheme (SW-LCAS) enabled, as follows:

Out of service and out of group members can be removed from VCG

Members with deleted cross connect can be removed from VCG

Errored members can be autonomously removed from VCG

Degraded bandwidth VCGs are supported

VCG is flexible with SW-LCAS enabled (VCG can run traffic as soon as the first cross-connect is provisioned on both sides of the transport)

6.2.3  Distance Extension (Enhanced Mode Only)

This following list describes the FC_MR-4 card distance extension capabilities.

Enabling of SAN extension over long distances through buffer-to-buffer (B2B) credit spoofing.

2300 Km for 1G ports (longer distances supported with lesser throughput)

1150 Km for 2G ports. (longer distances supported with lesser throughput)

Negotiation mechanism to identify whether a far-end FC-over-SONET card supports the Cisco proprietary B2B mechanism

Auto detection of FC switch B2B credits from FC-SW standards-based ELP frames

Support for manual provisioning of credits based on FC switch credits

Automatic GFP Buffers adjustment based on roundtrip latency between two SL ports

Automatic Credits recovery during SONET switchovers/failures

Insulation for FC switches from any SONET switchovers; no FC fabric reconvergences for SONET failures of less than or equal to 60 ms

6.2.4  Interoperability Features (Enhanced Mode Only)

The interoperability features are as follows:

Maximum Frame Size Setting to prevent accumulation of oversize performance monitoring parameters for VSAN frames

Ingress Filtering Disable for attachment to third party GFP over SONET/SDH equipment

6.2.5  Link Integrity

The link integrity features are as follows:

Data port disabled if upstream data port is not able to send over SONET/SDH Transport

Data port disabled if SONET/SDH transport is errored

6.2.6  Link Recovery

Link recovery has the following features:

Reduces the impact of SONET/SDH disruptions on attached fiber channel equipment.

Speeds up the recovery of ISL links (Inter Switch Links)

Allows the monitoring of Buffer to Buffer credit depletion due to SONET outage and the full recovery of the credits, thus preventing the slow decay of the bandwidth/throughput


Note Distance Extension and Link Recovery cannot be enabled at the same time.


6.3  FC_MR-4 Card Application

The FC_MR-4 card reliably transports carrier-class, private-line Fibre Channel/FICON transport service. Each FC_MR-4 card can support up to four 1-Gbps circuits or four 2-Gbps circuits. Four 1.0625 Gbps FC channels can be mapped into containers as small as STS1 (subrate), with a minimum of STS-24c/VC4-8c for full rate, and as large as STS48c/VC4-24c. Four 2.125 Gbps FC channels can be mapped into containers as small as STS1 (sub-ate), with a minimum of STS48c/VC4-24c for full rate, and as large as STS48c/VC4-24c.

The FC_MR-4 card incorporates features optimized for carrier-class applications such as:

Carrier-class Fibre Channel/FICON

50 ms of switch time through SONET/SDH protection as specified in Telcordia GR-253CORE

Hitless software upgrades

Remote Fibre Channel/FICON circuit bandwidth upgrades via integrated Cisco Transport Controller (CTC)

Multiple management options through CTC, Cisco Transport Manager (CTM), TL1, and Simple Network Management Protocol (SNMP)

The FC_MR-4 payloads can be transported over the following protection types:

Path protection

BLSR

Unprotected

Protection channel access (PCA)

The FC_MR-4 payloads can be transported over the following circuit types:

STS

STSn

STS-V


Note VT and VT-V circuits are not supported.


The FC_MR-4 card supports virtual concatenation (VCAT). See the "10.15  Virtual Concatenated Circuits" section on page 10-30.

The FC_MR-4 uses pluggable gigabit interface converters (GBICs) for client interfaces. See Table 5-21 on page 5-26 for a list of GBICs that are compatible with the FC_MR-4.


hometocprevnextglossaryfeedbacksearchhelp

Posted: Tue Nov 27 06:13:26 PST 2007
All contents are Copyright © 1992--2007 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.