cc/td/doc/product/ong/15400/r50docs
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table Of Contents

Hardware Specifications

B.1  Shelf Specifications

B.1.1  Bandwidth

B.1.2  Configurations

B.1.3  Cisco Transport Controller

B.1.4  External LAN Interface

B.1.5  TL1 Craft Interface

B.1.6  Modem Interface

B.1.7  Alarm Interface

B.1.8  EIA Interface (ANSI only)

B.1.9  BITS Interface (ANSI only)

B.1.10  System Timing

B.1.11  System Power

B.1.12  System Environmental Specifications

B.1.13  Dimensions

B.2  General Card Specifications

B.2.1  Power

B.2.2  Temperature

B.3  Common Control Card Specifications

B.3.1  TCC2 Card Specifications

B.3.2  TCC2P Card Specifications

B.3.3  AIC-I Card Specifications

B.3.4  AEP Specifications (ANSI only)

B.3.5  MIC-A/P FMEC Specifications (ETSI only)

B.3.6  MIC-C/T/P FMEC Specifications (ETSI only)

B.4  DWDM Card Specifications

B.4.1  OSCM Card Specifications

B.4.2  OSC-CSM Card Specifications

B.4.3  OPT-PRE Amplifier Card Specifications

B.4.4  OPT-BST Amplifier Card Specifications

B.4.5  OPT-BST-E Amplifier Card Specifications

B.4.6  32MUX-O Card Specifications

B.4.7  32DMX-O Card Specifications

B.4.8  32DMX Card Specifications

B.4.9  4MD-xx.x Card Specifications

B.4.10  AD-1C-xx.x Card Specifications

B.4.11  AD-2C-xx.x Card Specifications

B.4.12  AD-4C-xx.x Card Specifications

B.4.13  AD-1B-xx.x Card Specifications

B.4.14  AD-4B-xx.x Card Specifications

B.4.15  32WSS Card Specifications

B.5  Transponder and Muxponder Card Specifications

B.5.1  TXP_MR_10G Card Specifications

B.5.2  MXP_2.5G_10G Card Specifications

B.5.3  TXP_MR_2.5G and TXPP_MR_2.5G Card Specifications

B.5.4  MXP_MR_2.5G and MXPP_MR_2.5G Card Specifications

B.5.5  MXP_2.5G_10E Card Specifications

B.5.6  TXP_MR_10E Card Specifications

B.6  SFP Specifications

SFP Port Cabling Specifications

B.7  XFP Specifications

B.7.1  XFP Port Cabling Specifications


Hardware Specifications


This appendix contains hardware and software specifications for the ONS 15454 ANSI and ETSI shelf assemblies and cards.


Note Unless otherwise specified, "ONS 15454" refers to both ANSI and ETSI shelf assemblies.


B.1  Shelf Specifications

This section provides specifications for shelf bandwidth; a list of topologies; Cisco Transport Controller (CTC) specifications; the LAN, TL1, modem, and alarm specifications; timing, power, and environmental specifications; and shelf dimensions.

B.1.1  Bandwidth

The ONS 15454 has the following bandwidth specifications:

Total bandwidth: 240 Gbps

Data plane bandwidth: 160 Gbps

SONET/SDH plane bandwidth: 80 Gbps

B.1.2  Configurations

The ONS 15454 can be configured for the following dense wavelength division multiplexing (DWDM) topologies:

Hubbed rings

Multihubbed rings

Point-to-point

Linear

Linear with optical add/drop multiplexing (OADM)

B.1.3  Cisco Transport Controller

CTC, the ONS 15454 craft interface software, has the following specifications:

10BaseT

Advanced Timing, Communications, and Control (TCC2/TCC2P) card access: RJ-45 connector

Backplane access: LAN pin field (ANSI only)

Front Mount Electrical Connection (FMEC) access: LAN connector on MIC-C/T/P faceplate (ETSI only)

B.1.4  External LAN Interface

The ONS 15454 external LAN interface has the following specifications:

10BaseT Ethernet

Backplane access: LAN pin field (ANSI only)

FMEC access: LAN connector on MIC-C/T/P faceplate (ETSI only)

B.1.5  TL1 Craft Interface

The ONS 15454 TL1 craft interface has the following specifications:

Speed: 9600 bps

TCC2/TCC2P access: EIA/TIA-232 DB-9 type connector

Backplane access: CRAFT pin field (ANSI only)

B.1.6  Modem Interface

The ONS 15454 modem interface has the following specifications:

Hardware flow control

TCC2/TCC2P: EIA/TIA-232 DB-9 type connector

B.1.7  Alarm Interface

The ONS 15454 alarm interface has the following specifications:

ETSI

Visual: Critical, Major, Minor, Remote

Audible: Critical, Major, Minor, Remote

FMEC access: 62-Pin DB connector on MIC-A/P faceplate

Alarm inputs: Common 32-VDC output for all alarm-inputs, closed contact limited to 2 mA

Control outputs: Open contact maximum 60 VDC, closed contact maximum 100 mA

ANSI

Visual: Critical, Major, Minor, Remote

Audible: Critical, Major, Minor, Remote

Backplane access: Alarm pin fields

Alarm contacts: 0.045 mm, -48 V, 50 mA

B.1.8  EIA Interface (ANSI only)

The ONS 15454 electrical interface assembly (EIA) interface has the following specifications:

SMB: AMP #415504-3 75-ohm, 4-leg connectors

BNC: Trompeter #UCBJ224 75-ohm 4 leg connector (King or ITT are also compatible)

AMP Champ: AMP#552246-1 with #552562-2 bail locks

B.1.9  BITS Interface (ANSI only)

The ONS 15454 building integrated timing supply (BITS) interface has the following specifications:

2 DS-1 BITS inputs

2 derived DS-1 outputs

Backplane access: BITS pin field

B.1.10  System Timing

The ONS 15454 ANSI has the following system timing specifications:

Stratum 3 per Telcordia GR-253-CORE

Free running accuracy: +/- 4.6 ppm

Holdover stability: 3.7 x 10-7 per day, including temperature (< 255 slips in first 24 hours)

Reference: External BITS, line, internal

The ONS 15454 ETSI has the following system timing specifications:

Stratum 3E, per ITU-T G.813

Free running accuracy: +/- 4.6 ppm

Holdover stability: 3.7 exp -7 per day, including temperature (< 255 slips in first 24 hours)

Reference: External BITS, line, internal

B.1.11  System Power

The ONS 15454 ANSI has the following power specifications:

Input power: -48 VDC

Power consumption: 55 W (fan tray only); 650 W (maximum draw with cards)

Power requirements: -40.5 to -57 VDC

Power terminals: #6 Lug

ANSI shelf: 100-A fuse panel (minimum 30 A fuse per shelf)
HD shelf: 100-A fuse panel (minimum 35 A fuse per shelf)

The ONS 15454 ETSI has the following power specifications:

Input voltage: -48 VDC

Power consumption: Configuration dependent, 53 W for fan tray; 650 W (maximum draw with cards)

Power requirements:

Nominal: -48 VDC

Tolerance limits: -40.5 to -57.0 VDC

Power terminals: 3WK3 Combo-D power cable connector (MIC-A/P and MIC-C/T/P faceplates)

Fusing: 100 A fuse panel; minimum 30 A fuse per shelf

B.1.12  System Environmental Specifications

The ONS 15454 ANSI has the following environmental specifications:

Operating temperature: 32 to +131 degrees Farenheit (0 to +55 degrees Celsius); -40 to +139 degrees Farenheit (-40 to +65 degrees Celsius) with industrial temperature rated cards

Operating humidity: 5 to 95 percent, noncondensing

The ONS 15454 ETSI has the following environmental specifications:

Operating temperature: 32 to 104 degrees Fahrenheit (0 to +40 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

B.1.13  Dimensions

The ONS 15454 ANSI shelf assembly has the following dimensions:

Height: 18.5 in. (40.7 cm)

Width: 19 or 23 in. (41.8 or 50.6 cm) with mounting ears attached

Depth: 12 in. (26.4 cm) (5 in. or 12.7 cm projection from rack)

Weight: 55 lb (24.947 kg) empty

The ONS 15454 ETSI shelf assembly has the following dimensions:

Height: 616.5 mm (24.27 in.)

Width: 535 mm (17 in.) without mounting ears attached

Depth: 280 mm (11.02 in.)

Weight: 26 kg empty (57.3 lb)

B.2  General Card Specifications

This section provides power specifications and temperature ranges for all ONS 15454 cards.

B.2.1  Power

Table B-1 provides power consumption information for the ONS 15454 cards.

Table B-1 Individual Card Power Requirements 

Card Type
Card Name 
Watts
Amperes at -48 V
BTU/Hr.
Common Control Cards

TCC2/TCC2P

19.20

0.4

66.8

AIC-I

4.8

0.1

15.3

AEP

3

(from +5 VDC from AIC-I)

10.2

MIC-A/P

0.13

via TCC2/TCC2P

MIC-C/T/P

0.38

via TCC2/TCC2P

DWDM Cards

OSCM

Nominal 23

Maximum 26

Nominal 0.48

Maximum 0.54

Nominal 78.48

Maximum 88.71

OSC-CSM

Nominal 24

Maximum 27

Nominal 0.5

Maximum 0.56

Nominal 81.89

Maximum 92.12

OPT-PRE

Minimum 25

Nominal 30

Maximum39

Minimum 0.52

Nominal 0.5

Maximum 0.81

Minimum 85.3

Nominal 102.36

Maximum 88.71

OPT-BST

Nominal 30

Maximum 39

Nominal 0.63

Maximum 0.81

Nominal 102.36

Maximum 88.71

OPT-BST-E

Nominal 30

Maximum 39

Nominal 0.63

Maximum 0.81

Nominal 102.36

Maximum 88.71

32MUX-O

Nominal 16

Maximum 25

Nominal 0.33

Maximum 0.52

Nominal 54.59

Maximum 85.3

32DMX-O

Nominal 16

Maximum 25

Nominal 0.33

Maximum 0.52

Nominal 54.59

Maximum 85.3

32DMX

Nominal 15

Maximum 25

Nominal 0.31

Maximum 0.52

Nominal 51.21

Maximum 85

4MD-xx.x

Nominal 17

Maximum 25

Nominal 0.35

Maximum 0.52

Nominal 58.0

Maximum 85.3

AD-1C-xx.x

Nominal 17

Maximum 25

Nominal 0.35

Maximum 0.52

Nominal 58.0

Maximum 85.3

AD-2C-xx.x

Nominal 17

Maximum 25

Nominal 0.35

Maximum 0.52

Nominal 58.0

Maximum 85.3

AD-4C-xx.x

Nominal 17

Maximum 25

Nominal 0.35

Maximum 0.52

Nominal 58.0

Maximum 85.3

DWDM Cards

AD-1B-xx.x

Nominal 17

Maximum 25

Nominal 0.35

Maximum 0.52

Nominal 58.0

Maximum 85.3

AD-4B-xx.x

Nominal 17

Maximum 25

Nominal 0.35

Maximum 0.52

Nominal 58.0

Maximum 85.3

32WSS

Nominal 50

Maximum 65

Nominal 1.04

Maximum 1.35

Nominal 170

Maximum 221

Transponder and Muxponder Cards

TXP_MR_10G

35.001

0.73

119.5

TXP_MR_10E

Nominal 40

Maximum 50

Nominal 1.11

Maximum 1.04

Nominal 136.6

Maximum 170.7

TXP_MR_2.5G

35.001

0.73

119.5

TXPP_MR_2.5G

501

1.04

170.5

MXP_2.5G_10G

501

1.04

170.7

MXP_2.5G_10E

Nominal 40

Maximum 50

Nominal 1.11

Maximum 1.04

Nominal 136.6

Maximum 170.7

MXP_MR_2.5G

Nominal 50

Maximum 60

Nominal 1.04

Maximum 1.25

Nominal 170.7

Maximum 204

MXPP_MR_2.5G

Nominal 50

Maximum 60

Nominal 1.04

Maximum 1.25

Nominal 170.7

Maximum 204

1 Calculated power; measured power was not available at the time of publication.


B.2.2  Temperature

Table B-2 provides temperature ranges and product names for ONS 15454 cards.


Note The I-Temp symbol is displayed on the faceplate of an I-Temp compliant card. A card without this symbol is C-Temp compliant.


Table B-2 Card Temperature Ranges and Product Names 

Card Type
Card Name
C-Temp Product Name
(32 to 131 degrees Fahrenheit, 0 to +55 degrees Celsius)
I-Temp Product Name
(-40 to 149 degrees Fahrenheit, -40 to +65 degrees Celsius)
Common Control Cards

TCC2/TCC2P

15454-TCC2/TCC2P

AIC-I

15454-AIC-I

AEP

15454-AEP

MIC-A/P

15454-MIC-A/P

MIC-C/T/P

15454 MIC-C/T/P

DWDM Cards

OSCM

15454-OSCM

OSC-CSM

15454-OSC-CSM

OPT-PRE

15454-OPT-PRE

OPT-BST

15454-OPT-BST

OPT-BST-E

15454-OPT-BST-E

32MUX-O

15454-32 MUX-O

32DMX-O

15454-32 DMX-O

32DMX

15454-32-DMX

4MD-xx.x

15454-4MD-xx.x

AD-1B-xx.x

15454-AD-1B-xx.x

AD-4B-xx.x

15454-AD-4B-xx.x

AD-1C-xx.x

15454-AD-1C-xx.x

AD-2C-xx.x

15454-AD-2C-xx.x

AD-4C-xx.x

15454-AD-4C-xx.x

32WSS

15454-WSS

Transponder and Muxponder Cards

TXP_MR_10G

15454-TXPMR10G

TXP_MR_10E

15454-10EMRTXP

TXP_MR_2.5G

15454-2.5GMRTXP

TXPP_MR_2.5G

15454-2.5GMRTXP-P

MXP_2.5G_10G

15454-MXP2.5G10G

MXP_2.5G_10E

15454-4x2.5G10EMXP

MXP_MR_2.5G

15454-Datamux2.5GDM

MXPP_MR_2.5G

15454-Datamux2.5GDMP


B.3  Common Control Card Specifications

This section provides specifications for the TCC2, TCC2P, AIC, and AIC-I cards, the alarm expansion panel (AEP), and the MIC-A/P and MIC-C/T/P FMECs.

For compliance information, refer to the Cisco Optical Transport Products Safety and Compliance Information document.

B.3.1  TCC2 Card Specifications

The TCC2 card has the following specifications:

CTC software

Interface: EIA/TIA-232 (local craft access, on TCC2 faceplate)

Interface: 10BaseT LAN (on TCC2 faceplate)

Interface: 10BaseT LAN (through the backplane)

Synchronization

Stratum 3, per Telcordia GR-253-CORE

Free running access: Accuracy +/- 4.6 ppm

Holdover stability: 3.7 x 10-7 per day including temperature (< 255 slips in first 24 hours)

Reference: External BITS, line, internal

Supply voltage monitoring

Both supply voltage inputs are monitored.

Normal operation: -40.5 to -56.7 V

Undervoltage: Major alarm

Overvoltage: Major alarm

Environmental

Operating temperature: -40 to +149 degrees Fahrenheit (-40 to +65 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Power consumption: 26.00 W, 0.54 A at -48 V, 88.8 BTU/hr

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Depth with backplane connector: 235 mm (9.250 in.)

Weight not including clam shell: 0.7 kg (1.5 lb)

B.3.2  TCC2P Card Specifications

The TCC2P card has the following specifications:

CTC software

Interface: EIA/TIA-232 (local craft access, on TCC2P faceplate)

Interface: 10BaseT LAN (on TCC2P faceplate)

Interface: 10BaseT LAN (through the backplane)

Synchronization

Stratum 3, per Telcordia GR-253-CORE

Free running access: Accuracy +/- 4.6 ppm

Holdover stability: 3.7 * 10 exp - 7 per day including temperature (< 255 slips in first 24 hours)

Reference: External BITS, line, internal

Supply voltage monitoring

Both supply voltage inputs are monitored.

Normal operation: -40.5 to -56.7 V (in -48 VDC systems)

Undervoltage: Major alarm

Overvoltage: Major alarm

Environmental

Operating temperature: -40 to +149 degrees Fahrenheit (-40 to +65 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Power consumption: 26.00 W, 0.54 A at -48 V, 88.8 BTU/hr

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Depth with backplane connector: 9.250 in. (235 mm)

Weight not including clam shell: 1.5 lb (0.7 kg)

B.3.3  AIC-I Card Specifications

The AIC-I card has the following specifications:

Alarm inputs

Number of inputs: 12 without AEP, 32 with AEP

Opto-coupler isolated

Label customer provisionable

Severity customer provisionable

Common 32 V output for all alarm inputs

Each input limited to 2 mA

Termination: Wire-wrap on backplane without AEP, on AEP connectors with AEP

Alarm outputs

Number of outputs: 4 (user configurable as inputs) without AEP, 16 with AEP

Switched by opto MOS (metal oxide semiconductor)

Triggered by definable alarm condition

Maximum allowed open circuit voltage: 60 VDC

Maximum allowed closed circuit current: 100 mA

Termination: Wire-wrap on backplane without AEP, on AEP connectors with AEP

Express orderwire/local orderwire (EOW/LOW)

ITU-T G.711, ITU-T G.712, Telcordia GR-253-CORE

A-law, mu-law


Note Due to the nature of mixed coding, in a mixed-mode (A-law/mu-law) configuration, the orderwire is not ITU-T G.712 compliant.


Orderwire party line

Dual tone, multifrequency (DTMF) signaling

User data channel (UDC)

Bit rate: 64 kbps, codirectional

ITU-T G.703

Input/output impedance: 120 ohm

Termination: RJ-11 connectors

Data communications channel (DCC)

Bit rate: 576 kbps

EIA/TIA-485/V11

Input/output impedance: 120 ohm

Termination: RJ-45 connectors

ACC connection for additional alarm interfaces

Connection to AEP

Power monitoring alarming states:

Power failure (0 to -38 VDC)

Undervoltage (-38 to -40.5 VDC)

Overvoltage (beyond -56.7 VDC)

Environmental

Operating temperature: -40 to 149 degrees Fahrenheit (-40 to +65 degrees Celsius)

Operating humidity: 5 to 95 percent, noncondensing

Power consumption (including AEP, if used): 8.00 W, 0.17 A, 27.3 BTU/hr

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Weight: 1.8 lb (0.82 kg)

B.3.4  AEP Specifications (ANSI only)

The AEP has the following specifications:

Alarm inputs

Number of inputs: 32

Optocoupler isolated

Label customer provisionable

Severity customer provisionable

Common 32 V output for all alarm inputs

Each input limited to 2 mA

Termination: 50-pin AMP champ connector

Alarm outputs

Number of outputs: 16

Switched by opto MOS

Triggered by definable alarm condition

Maximum allowed open circuit voltage: 60 VDC

Maximum allowed closed circuit current: 100 mA

Termination: 50-pin AMP champ connector

Environmental

Overvoltage protection: as in ITU-T G.703 Annex B

Operating temperature: -40 to +65 degrees Celsius (-40 to +149 degrees Fahrenheit)

Operating humidity: 5 to 95 percent, noncondensing

Power consumption: 3.00 W max., from +5 VDC from AIC-I, 10.2 BTU/hr max.

Dimensions of AEP board

Height: 20 mm (0.79 in.)

Width: 330 mm (13.0 in.)

Depth: 89 mm (3.5 in.)

Weight: 0.18 kg (0.4 lb)

B.3.5  MIC-A/P FMEC Specifications (ETSI only)

The MIC-A/P FMEC card has the following specifications:

Power supply input BATTERY B

System supply voltage: Nominal -48 VDC
Tolerance limits: -40.5 to -57.0 VDC

Connector: 3WK3 Combo-D power cable connector

Alarm outputs

Voltage (open contact): Maximum 60 VDC

Current (closed contact): Maximum 250 mA

Connector: 62-pin DB connector (common for inputs/outputs)

Alarm inputs

Voltage (open contact): Maximum 60 VDC

Current (closed contact): Maximum 2 mA

Connector: 62-pin DB connector (common for inputs/outputs)

Environmental

Operating temperature: -5 to +45 degrees Celsius (+23 to +113 degrees Fahrenheit)

Operating humidity: 5 to 95 percent, noncondensing

Power consumption: 0.13 W (provided by +5 V from the TCC2/TCC2P card), 0.44 BTU/hr

Dimensions

Height: 182 mm (7.165 in.)

Width: 32 mm (1.25 in.)

Depth: 92 mm (3.62 in.)

Depth with backplane connector: 98 mm (3.87 in.)

Weight not including clam shell: 0.2 kg (0.5 lb)

B.3.6  MIC-C/T/P FMEC Specifications (ETSI only)

The MIC-C/T/P FMEC card has the following specifications:

Power supply input BATTERY A

System supply voltage: Nominal -48 VDC
Tolerance limits: -40.5 to -57.0 VDC

Connector: 3WK3 Combo-D power cable connector

Timing connector

Frequency: 2.048 MHz +/-10 ppm

Signal level: 0.75 to 1.5 V

Impedance: 75 ohms +/-5 percent (switchable by jumper to high impedance > 3 kohms)


Note 120 ohms balanced impedance is possible with external matching cable.


Cable attenuation: Up to 6 dB at 2 MHz

Connectors: 1.0/2.3 miniature coax connector

System management serial port:

System management serial port craft interface

Modem port (for future use)

Connectors: 8-pin RJ-45

System management LAN port connectors:

Signal: IEEE 802.3 10BaseT

Connectors: 8-pin RJ-45

Environmental

Operating temperature: -5 to +45 degrees Celsius (+23 to +113 degrees Fahrenheit)

Operating humidity: 5 to 95 percent, noncondensing

Power consumption: 0.38 W (provided by +5 V from the TCC2/TCC2P card), 1.37 BTU/hr

Dimensions

Height: 182 mm (7.165 in.)

Width: 32 mm (1.25 in.)

Depth: 92 mm (3.62 in.)

Depth with backplane connector: 98 mm (3.87 in.)

Weight not including clam shell: 0.2 kg (0.5 lb)

B.4  DWDM Card Specifications

This section provides specifications for the OSCM, OSC-CSM, OPT-PRE amplifier, OPT-BST amplifier, OPT-BST-E amplifier, 32MUX-O, 32DMX-O, 32DMX, 4MD-xx.x, AD-IC-xx.x, AD-2C-xx.x, AD-4C-xx.x, AD-1B-xx.x, AD-4B-xx.x, and 32WSS cards.

For compliance information, refer to the Cisco Optical Transport Products Safety and Compliance Information document.

B.4.1  OSCM Card Specifications

The OSCM card has the following specifications:

Line

Bit rate: 155 Mbps

Code: Scrambled non-return to zero (NRZ)

Loopback modes: None

Connector: Duplex LC

Compliance: Telcordia GR-253-CORE, ITU-T G.957

Transmitter optical service channel (OSC) signal

Maximum transmitter output power: -1 dBm

Minimum transmitter output power: -5 dBm

Nominal wavelength: 1510-nm +/-10 nm

Variable optical attenuator (VOA) necessary in the transmit path to adjust the in-fiber optical power level

Receiver OSC signal

Maximum receiver level: -8 dBm at 10-10 bit error rate (BER)

Minimum receiver level: -40 dBm at 10-10 BER

Span budget: 40-dB span budget (about 150 km assuming fiber path loss equals 0.25 dB/km)

Jitter tolerance: Telcordia GR-253/G.823 compliant

Environmental

Operating temperature:

C-Temp: -5 to +55 degrees Celsius (+23 to +131 degrees Fahrenheit)

Operating humidity: 5 to 95 percent, noncondensing

Dimensions

Height: 12.65 in. (321.3 mm)

Width: 0.92 in. (23.4 mm)

Depth: 9.00 in. (228.6 mm)

B.4.2  OSC-CSM Card Specifications

The OSC-CSM card has the following specifications:

Line

Bit rate: 155 Mbps

Code: Scrambled NRZ

Loopback modes: None

Connector: Duplex LC

Compliance: Telcordia GR-253-CORE, ITU-T G.957

Transmitter OSC signal

Maximum transmitter output power: -2 dBm

Minimum transmitter output power: -24 dBm

Nominal wavelength: 1510-nm +/-10 nm

VOA is necessary in the transmit path to adjust the in-fiber optical power level

Receiver OSC signal

Maximum receiver level: -8 dBm at 10-10 BER

Minimum receiver level: -40 dBm at 10-10 BER

Span loss budget: 35-dB span budget (approximately 140 km assuming that the fiber path loss is equal to 0.25 dB/km)

Jitter tolerance: Telcordia GR-253/G.823 compliant

Environmental

Operating temperature:

C-Temp: -5 to +55 degrees Celsius (+23 to +131 degrees Fahrenheit)

Operating humidity: 5 to 95 percent, noncondensing

Dimensions

Height: 12.65 in. (321.3 mm)

Width: 0.92 in. (23.4 mm)

Depth: 9.00 in. (228.6 mm)

B.4.3  OPT-PRE Amplifier Card Specifications

The OPT-PRE amplifier card has the following specifications:

Optical characteristics:

Total operating wavelength range: 1530 to 1561.3 nm

Gain ripple (peak to valley): 1.5 dB

Mid-access loss (MAL) range (for dispersion compensation unit [DCU]): 3 to 9 dB

Gain range: 5 to 38.5 dBm in constant power mode, 5 to 28 dBm in constant gain mode

Minimum gain (standard range): 5.0 dBm

Maximum gain (standard range with programmable gain tilt): 21 dBm

Maximum gain (extended range with uncontrolled gain tilt): 38.5 dBm

Gain and power regulation over/undershoot: 0.5 dB

Limited maximum output power: 17.5 dBm

Maximum output power (with full channel load): 17 dB

Minimum output power (with one channel): -1 dBm

Input power (Pin) range at full channel load: -21.5 to 12 dBm

Input power (Pin) range at single channel load: -39.5 to -6 dBm

Noise figure at G3 21 dB = 6.5 dB

OSC filter drop (channels) insertion loss maximum: 1 dB

OSC filter drop (OSC) insertion loss maximum: 1.8 dB

OSC filter add (OSC) insertion loss maximum: 1.3 dB

Optical connectors: LC-UPC/2

Environmental

Operating temperature:

C-Temp: -5 to +55 degrees Celsius (+23 to +131 degrees Fahrenheit)

Operating humidity: 5 to 85 percent, noncondensing

Dimensions

Height: 12.65 in. (332 mm)

Width: 0.92 in. (24 mm)

Depth: 9.00 in. (240 mm)

B.4.4  OPT-BST Amplifier Card Specifications

The OPT-BST amplifier card has the following specifications:

Optical characteristics:

Total operating wavelength range: 1530 to 1561.3 nm

Gain ripple (peak to valley): 1.5 dB

Gain range: 5 to 20 dBm with programmable gain tilt

Gain and power regulation over/undershoot: 0.5 dB

Limited maximum output power: 17.5 dBm

Maximum output power (with full channel load): 17 dB

Minimum output power (with one channel): -1 dBm

Input power (Pin) range at full channel load: -3 to 12 dBm

Input power (Pin) range at single channel load: -21 to -6 dBm

Noise figure at G3 20 dB = 6 dB

OSC filter drop (channels) insertion loss maximum: 1 dB

OSC filter drop (OSC) insertion loss maximum: 1.8 dB

OSC filter add (OSC) insertion loss maximum: 1.3 dB

Optical connectors: LC-UPC/2

Environmental

Operating temperature:

C-Temp: -5 to +55 degrees Celsius (+23 to +131 degrees Fahrenheit)

Operating humidity: 5 to 85 percent, noncondensing

Dimensions

Height: 12.65 in. (332 mm)

Width: 0.92 in. (24 mm)

Depth: 9.00 in. (240 mm)

B.4.5  OPT-BST-E Amplifier Card Specifications

The OPT-BST-E amplifier card has the following specifications:

Optical characteristics:

Total operating wavelength range: 1530 to 1561.3 nm

Gain ripple (peak to valley): 1.8 dB

Gain range: 8 to 23 dB with programmable gain tilt

Extended gain range: 23 to 26 dB with gain tilt uncontrolled

Gain and power regulation over/undershoot: 0.5 dB

Limited maximum output power: 20.5 dBm

Maximum output power (with full channel load): 20 dB

Minimum output power (with one channel): -1 dBm

Input power (Pin) range at full channel load: -6 to 12 dBm

Input power (Pin) range at single channel load: -26 to -8 dBm

Noise figure at G3 23 dB = 6 dB

OSC filter drop (channels) insertion loss maximum: 1 dB

OSC filter drop (OSC) insertion loss maximum: 1.8 dB

OSC filter add (OSC) insertion loss maximum: 1.3 dB

Optical connectors: LC-UPC/2

Environmental

Operating temperature:

C-Temp: -5 to +55 degrees Celsius (+23 to +131 degrees Fahrenheit)

Operating humidity: 5 to 85 percent, noncondensing

Dimensions

Height: 12.65 in. (332 mm)

Width: 0.92 in. (24 mm)

Depth: 9.00 in. (240 mm)

B.4.6  32MUX-O Card Specifications

The 32 MUX-O card optical specifications are listed in Table B-3.


Note For power specifications, refer to the "15.1.7  Multiplexer, Demultiplexer, and OADM Card Interface Classes" section on page 15-6.


Table B-3 32MUX-O Optical Specifications 

Parameter
Note
Condition
Min
Max
Unit

Tx filter shape (-1 dB bandwidth)

All standard operating procedures (SOP) and within whole operating temperature range

In 1/32—Out beginning of life (BOL)

+/-180

+/-300

pm

In 1/32—Out end of life (EOL)

+/-160

+/-300

pm

Insertion loss

All SOP and within whole operating temperature range

In 1/32—Out BOL

4

8.0

dB

In 1/32—Out EOL

4

8.5

dB

VOA dynamic range

25

dB

Optical monitor tap-splitting ratio on monitor port

Optical monitor port with respect to output port in multiplexer only

19

21

dB

Maximum optical input power

300

mW


The 32MUX-O card has the following additional specifications:

Environmental

Operating temperature:

C-Temp: -5 to +55 degrees Celsius (+23 to +131 degrees Fahrenheit)

Operating humidity: 5 to 95 percent relative humidity (RH)

Dimensions

Height: 12.65 in. (321.3 mm)

Width: 1.84 in. (46.8 mm)

Depth: 9.00 in. (228.6 mm)

B.4.7  32DMX-O Card Specifications

The 32DMX-O card optical specifications are listed in Table B-4.


Note For power specifications, see the "15.1.7  Multiplexer, Demultiplexer, and OADM Card Interface Classes" section on page 15-6.


Table B-4 32DMX-O Optical Specifications 

Parameter
Note
Condition
Min
Max
Unit

Rx filter shape (-1 dB bandwidth)

All SOP and within whole operating temperature range

In 1/32—Out BOL

+/-180

+/-300

pm

In 1/32—Out EOL

+/-160

+/-300

pm

Insertion loss

All SOP and within whole operating temperature range

In 1/32—Out BOL

4

8.0

dB

In 1/32—Out EOL

4

8.5

dB

VOA dynamic range

25

dB

Maximum optical input power

300

mW


The 32DMX-O card has the following additional specifications:

Environmental

Operating temperature:

C-Temp: -5 to +55 degrees Celsius (+23 to +131 degrees Fahrenheit)

Operating humidity: 5 to 95 percent RH

Dimensions

Height: 12.65 in. (321.3 mm)

Width: 1.84 in. (46.8 mm)

Depth: 9.00 in. (228.6 mm)

B.4.8  32DMX Card Specifications

The 32DMX card optical specifications are listed in Table B-5.


Note For power specifications, see the "15.1.7  Multiplexer, Demultiplexer, and OADM Card Interface Classes" section on page 15-6.


Table B-5 32DMX Optical Specifications 

Parameter
Note
Condition
Min
Typical
Max
Units

-1 dB bandwidth

All SOP and within whole operating temperature range, connectors included, and for maximum VOA operating attenuation.

COM RX => TX 1, 32 (OUT)

+/-110

pm

-3 dB bandwidth

+/-200

pm

Insertion loss

All SOP, and within whole operating temperature range, connectors included.

COM RX => TX 1, 32

5.5

dB

VOA dynamic range

COM RX => TX 1, 32

25

dB

Maximum optical input power

300

mW


The 32DMX channel plan is shown in Table B-6. All 32DMX client interfaces must comply with this plan.

Table B-6 32DMX Channel Plan 

Channel Number
Band
Channel ID
Frequency (GHz)
Wavelength (nm)

1

1

30.3

195.9

1530.33

2

31.2

195.8

1531.12

3

31.9

195.7

1531.90

4

32.6

195.6

1532.68

5

2

34.2

195.4

1534.25

6

35.0

195.3

1535.04

7

35.8

195.2

1535.82

8

36.6

195.1

1536.61

9

3

38.1

194.9

1538.19

10

38.9

194.8

1538.98

11

39.7

194.7

1539.77

12

40.5

194.6

1540.56

13

4

42.1

194.4

1542.14

14

42.9

194.3

1542.94

15

43.7

194.2

1543.73

16

44.5

194.1

1544.53

17

5

46.1

193.9

1546.12

18

46.9

193.8

1546.92

19

47.7

193.7

1547.72

20

48.5

193.6

1548.51

21

6

50.1

193.4

1550.12

22

50.9

193.3

1550.92

23

51.7

193.2

1551.72

24

52.5

193.1

1552.52

25

7

54.1

192.9

1554.13

26

54.9

192.8

1554.94

27

55.7

192.7

1555.75

28

56.5

192.6

1556.55

29

8

58.1

192.4

1558.17

30

58.9

192.3

1558.98

31

59.7

192.2

1559.79

32

60.6

192.1

1560.61


The 32DMX card has the following additional specifications:

Environmental

Operating temperature:

C-Temp: -5 to +55 degrees Celsius (+23 to +131 degrees Fahrenheit)

Operating humidity: 5 to 95 percent RH

Dimensions

Height: 12.65 in. (321.3 mm)

Width: 0.92 in. (23.4 mm)

Depth: 9.00 in. (228.6 mm)

B.4.9  4MD-xx.x Card Specifications

The 4MD-xx.x card optical specifications are listed in Table B-7.


Note For power specifications, see the "15.1.7  Multiplexer, Demultiplexer, and OADM Card Interface Classes" section on page 15-6.


Table B-7 4MD-xx.x Optical Specifications 

Parameter
Note
Condition
Min
Max
Unit

Trx filter shape (-0.5 dB bandwidth TrxBW2)

All SOP and within whole operating temperature range

COM Rx—xx.xx Tx

COM Rx—yy.yy Tx

COM Rx—zz.zz Tx

COM Rx—kk.kk Tx

+/-180

pm

xx.xx Rx—COM Tx

yy.yy Rx—COM Tx

zz.zz Rx—COM Tx

kk.kk Rx—COM Tx

Insertion loss demultiplexer section

All SOP and within whole operating temperature range

COM Rx—xx.xx Tx

1.9

dB

COM Rx—yy.yy Tx

2.4

dB

COM Rx—zz.zz Tx

2.8

dB

COM Rx—kk.kk Tx

3.3

dB

Insertion loss multiplexer section

All SOP and within whole operating temperature range (two connectors included)

xx.xx Rx—COM Tx

3.6

dB

yy.yy Rx—COM Tx

3.2

dB

zz.zz Rx—COM Tx

3.0

dB

kk.kk Rx—COM Tx

2.6

dB

VOA dynamic range

25

dB

Maximum optical input power

300

mW


The 4MD-xx.x card has the following additional specifications:

Environmental

Operating temperature:

C-Temp: -5 to +55 degrees Celsius (+23 to +131 degrees Fahrenheit)

Operating humidity: 5 to 95 percent RH

Dimensions

Height: 12.65 in. (321.3 mm)

Width: 0.92 in. (23.4 mm)

Depth: 9.00 in. (228.6 mm)

B.4.10  AD-1C-xx.x Card Specifications

Table B-8 lists the AD-1C-xx.x optical specifications.

Table B-8 AD-1C-xx.x Card Optical Specifications 

Parameter
Note
Condition
Min
Max
Unit

Trx filter shape
(-0.5 dB bandwidth)
TrxBW2

All SOP and within whole operating temperature range

COM Rx—xx.xx Tx
xx.xx Rx—COM Tx

+/-180

pm

Rfx filter shape
(-0.5 dB bandwidth)
RfxBW2

All SOP and within whole operating temperature range

COM Rx—Exp Tx
Exp Rx—COM Tx

+/-180

pm

Insertion loss
(drop section)

All SOP and within whole operating temperature range (two connectors included)

COM Rx—xx.xx Tx

2.0

dB

Insertion loss
(express section)

VOA at minimum attenuation; all SOP and within whole operating temperature range (two connectors included)

COM Rx—Exp Tx
Exp Rx—COM Tx

2.4 or 1.2

dB

Insertion loss
(add section)

VOA at minimum attenuation; all SOP and within whole operating temperature range (two connectors included)

xx.xx Rx—COM Tx

2.6

dB

VOA dynamic range

30

dB

Maximum optical input power

300

mW


AD-1C-xx.x optical input and output power varies with amplifier output levels and the class of transponder interfaces used. See Table 15-3 on page 15-6 through Table 15-5 on page 15-8 for this information.

The AD-1C-xx.x card has the following additional specifications:

Environmental

Operating temperature:

C-Temp: -5 to +55 degrees Celsius (+23 to +131 degrees Fahrenheit)

Operating humidity: Telcordia GR-63 5.1.1.3 compliant; 5 to 95 percent RH

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.92 in. (23.4 mm)

Depth: 9.0 in. (228.6 mm)

B.4.11  AD-2C-xx.x Card Specifications

Table B-9 lists the AD-2C-xx.x optical specifications.

Table B-9 AD-2C-xx.x Card Optical Specifications 

Parameter
Note
Condition
Min
Max
Unit

Trx filter shape
(-0.5 dB bandwidth)
TrxBW2

All SOP and within whole operating temperature range

COM Rx—xx.xx Tx
COM Rx—yy.yy Tx

+/-180

pm

xx.xx Rx—COM Tx
yy.yy Rx—COM Tx

+/-180

Rfx filter shape
(-0.5 dB bandwidth)
RfxBW2

All SOP and within whole operating temperature range

COM Rx—Exp Tx
Exp Rx—COM Tx

+/-180

pm

Insertion loss
(drop section)

All SOP and within whole operating temperature range (two connectors included)

COM Rx—xx.xx Tx

2.0

dB

COM Rx—yy.yy Tx

2.4

dB

Insertion loss
(express section)

VOA at minimum attenuation; all SOP and within whole operating temperature range (two connectors included)

COM Rx—Exp Tx

2.7

dB

Exp Rx—COM Tx

1.6

dB

Insertion loss
(add section)

VOA at minimum attenuation; all SOP and within whole operating temperature range (two connectors included)

xx.xx Rx—COM Tx

3.1

dB

yy.yy Rx—COM Tx

2.7

dB

VOA dynamic range

30

dB

Maximum optical input power

300

mW


AD-2C-xx.x optical input and output power varies with amplifier output levels and the class of transponder interfaces used. See Table 15-3 on page 15-6 through Table 15-5 on page 15-8 for this information.

The AD-2C-xx.x has the following additional specifications:

Environmental

Operating temperature:

C-Temp: -5 to +55 degrees Celsius (+23 to +131 degrees Fahrenheit)

Operating humidity: Telcordia GR-63 5.1.1.3 compliant; 5 to 95 percent RH

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.92 in. (23.4 mm)

Depth: 9.0 in. (228.6 mm)

B.4.12  AD-4C-xx.x Card Specifications

Table B-10 lists the AD-4C-xx.x optical specifications.

Table B-10 AD-4C-xx.x Optical Specifications 

Parameter
Note
Condition
Min
Max
Unit

Channel grid

See Table B-11. The channel plan for the AD-4C-xx.x card is identical to the channel plan for the AD-1B-xx.x card.

Trx filter shape
(-0.5 dB bandwidth)
TrxBW2

All SOP and within whole operating temperature range

COM Rx—xx.xx Tx
COM Rxyy.yy Tx
COM Rx—zz.zz Tx
COM Rx—kk.kk Tx
xx.xx Rx—COM Tx
yy.yy Rx—COM Tx

+/-180

pm

Rfx filter shape
(-1 dB bandwidth)
RfxBW2

All SOP and within whole operating temperature range

COM Rx—Exp Tx
Exp Rx—COM Tx

pm

Insertion loss
(drop section)

All SOP and within whole operating temperature range (two connectors included)

COM Rx—xx.xx Tx

5.5

dB

COM Rx—yy.yy Tx

5.0

dB

COM Rx—zz.zz Tx

4.5

dB

COM Rx—kk.kk Tx

4.1

dB

Insertion loss
(express section)

VOA at minimum attenuation; all SOP and within whole operating temperature range (two connectors included)

COM Rx—Exp Tx

2.7

dB

Exp Rx—COM Tx

1.2

dB

Insertion loss
(add section)

VOA at minimum attenuation; all SOP and within whole operating temperature range (two connectors included)

xx.xx Rx—COM Tx

3.9

dB

yy.yy Rx—COM Tx

4.3

dB

zz.zz Rx—COM Tx

4.5

dB

kk.kk Rx—COM Tx

4.9

dB

VOA dynamic range

30

dB

Maximum optical input power

300

mW


AD-4C-xx.x optical input and output power varies with amplifier output levels and the class of transponder interfaces used. See Table 15-3 on page 15-6 through Table 15-5 on page 15-8 for this information.

The AD-4C-xx.x has the following additional specifications:

Environmental

Operating temperature:

C-Temp: -5 to +55 degrees Celsius (+23 to +131 degrees Fahrenheit)

Operating humidity: Telcordia GR-63 5.1.1.3 compliant; 5 to 95 percent RH

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.92 in. (23.4 mm)

Depth: 9.0 in. (228.6 mm)

B.4.13  AD-1B-xx.x Card Specifications

Table B-11 lists the unit names, band IDs, channel IDs, frequencies, and wavelengths assigned to the eight versions of the AD-1B-xx.x card.

Table B-11 AD-1B-xx.x Channel Allocation Plan by Band 

Unit Name
Band ID
Channel ID
Frequency (GHz)
Wavelength (nm)

AD-1B-30.3

B30.3

30.3

195.9

1530.33

30.7

195.85

1530.72

31.1

195.8

1531.12

31.5

195.75

1531.51

31.9

195.7

1531.90

32.2

195.65

1532.29

32.6

195.6

1532.68

33.3

195.55

1533.07

AD-1B-34.2

B34.2

34.2

195.4

1534.25

34.6

195.35

1534.64

35.0

195.3

1535.04

35.4

195.25

1535.43

35.8

195.2

1535.82

36.2

195.15

1536.22

36.6

195.1

1536.61

37.0

195.05

1537.00

AD-1B-38.1

B38.1

38.1

194.9

1538.19

38.5

194.85

1538.58

38.9

194.8

1538.98

39.3

194.75

1539.37

39.7

194.7

1539.77

40.1

194.65

1540.16

40.5

194.6

1540.56

40.9

194.55

1540.95

AD-1B-42.2

B42.1

42.1

194.4

1542.14

42.5

194.35

1542.54

42.9

194.3

1542.94

43.3

194.25

1543.33

43.7

194.2

1543.73

44.1

194.15

1544.13

44.5

194.1

1544.53

44.9

194.05

1544.92

AD-1B-46.1

B46.1

46.1

193.9

1546.12

46.5

193.85

1546.52

46.9

193.8

1546.92

47.3

193.75

1547.32

47.7

193.7

1547.72

48.1

193.65

1548.11

48.5

193.6

1548.51

48.9

193.55

1548.91

AD-1B-50.1

B50.1

50.1

193.4

1550.12

50.5

193.35

1550.52

50.9

193.3

1550.92

51.3

193.25

1551.32

51.7

193.2

1551.72

52.1

193.15

1552.12

52.5

193.1

1552.52

52.9

193.05

1552.93

AD-1B-54.1

B54.1

54.1

192.9

1554.13

54.5

192.85

1554.54

54.9

192.8

1554.94

55.3

192.75

1555.34

55.7

192.7

1555.75

56.1

192.65

1556.15

56.5

192.6

1556.96

56.9

192.55

1556.96

AD-1B-58.1

B58.1

58.1

192.4

1558.17

58.5

192.35

1558.58

58.9

192.3

1558.98

59.3

192.25

1559.39

59.7

192.2

1559.79

60.2

192.15

1560.20

60.6

192.1

1560.61

61.0

192.05

1561.01


Table B-12 lists AD-1B-xx.x optical specifications.

Table B-12 AD-1B-xx.x Optical Specifications 

Parameter
Note
Condition
Min
Max
Unit

-1 dB bandwidth

All SOP and within whole operating environmental range

COM Rx—Band Tx
Band Rx—COM Tx

3.6

nm

-1 dB bandwidth

All SOP and within whole operating temperature range

COM Rx—Exp Tx
Exp Rx—COM Tx

Refer to Table B-13.

nm

Insertion loss
(drop section)

All SOP and within whole operating environmental range; two connectors included, VOA set at minimum attenuation

COM Rx—Band Tx

3.0

dB

Insertion loss
(express section)

All SOP and within whole operating environmental range; two connectors included

Exp Rx—COM Tx

1.6

dB

All SOP and within whole operating environmental range; two connectors included, VOA set at its minimum attenuation

COM Rx—Exp Tx

2.2

dB

Insertion loss
(add section)

All SOP and within whole operating environmental range; two connectors included

Band Rx—COM Tx

2.2

dB

VOA dynamic range

30

dB

Maximum optical input power

300

mW


Table B-13 lists the range of wavelengths for the receive (express) band.

Table B-13 AD-1B-xx.x Transmit and Receive Dropped Band Wavelength Ranges 

Tx (Dropped) Band
Rx (Express) Band
Left Side (nm)
Right Side (nm)

B30.3

Wavelengths 1533.825 or higher

B34.2

Wavelengths 1533.395 or lower

Wavelengths 1537.765 or higher

B38.1

Wavelengths 1537.325 or lower

Wavelengths 1541.715 or higher

42.1

Wavelengths 1541.275 or lower

Wavelengths 1545.695 or higher

46.1

Wavelengths 1545.245 or lower

Wavelengths 1549.695 or higher

50.1

Wavelengths 1549.235 or lower

Wavelengths 1553.705 or higher

54.1

Wavelengths 1553.255 or lower

Wavelengths 1557.745 or higher

58.1

Wavelengths 1557.285 or lower


AD-1B-xx.x optical input and output power varies with amplifier output levels and the class of transponder interfaces used. See Table 15-3 on page 15-6 through Table 15-5 on page 15-8 for this information.

The AD-1B-xx.x card has the following additional specifications:

Environmental

Operating temperature:

C-Temp: -5 to +55 degrees Celsius (+23 to +131 degrees Fahrenheit)

Operating humidity: Telcordia GR-63 5.1.1.3 compliant; 5 to 95 percent RH

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.92 in. (23.4 mm)

Depth: 9.0 in. (228.6 mm)

B.4.14  AD-4B-xx.x Card Specifications

Table B-14 lists the unit names, band IDs, channel IDs, frequencies, and wavelengths assigned to the two versions of the card.

Table B-14 AD-4B-xx.x Channel Allocation Plan by Band 

Unit Name
Band ID
Channel ID
Frequency (GHz)
Wavelength (nm)

AD-4B-30.3

B30.3

30.3

195.9

1530.33

30.7

195.85

1530.72

31.1

195.8

1531.12

31.5

195.75

1531.51

31.9

195.7

1531.90

32.2

195.65

1532.29

32.6

195.6

1532.68

33.3

195.55

1533.07

B34.2

34.2

195.4

1534.25

34.6

195.35

1534.64

35.0

195.3

1535.04

35.4

195.25

1535.43

35.8

195.2

1535.82

36.2

195.15

1536.22

36.6

195.1

1536.61

37.0

195.05

1537.00

B38.1

38.1

194.9

1538.19

38.5

194.85

1538.58

38.9

194.8

1538.98

39.3

194.75

1539.37

39.7

194.7

1539.77

40.1

194.65

1540.16

40.5

194.6

1540.56

40.9

194.55

1540.95

B42.1

42.1

194.4

1542.14

42.5

194.35

1542.54

42.9

194.3

1542.94

43.3

194.25

1543.33

43.7

194.2

1543.73

44.1

194.15

1544.13

44.5

194.1

1544.53

44.9

194.05

1544.92

AD-4B-46.1

B46.1

46.1

193.9

1546.12

46.5

193.85

1546.52

46.9

193.8

1546.92

47.3

193.75

1547.32

47.7

193.7

1547.72

48.1

193.65

1548.11

48.5

193.6

1548.51

48.9

193.55

1548.91

B50.1

50.1

193.4

1550.12

50.5

193.35

1550.52

50.9

193.3

1550.92

51.3

193.25

1551.32

51.7

193.2

1551.72

52.1

193.15

1552.12

52.5

193.1

1552.52

52.9

193.05

1552.93

B54.1

54.1

192.9

1554.13

54.5

192.85

1554.54

54.9

192.8

1554.94

55.3

192.75

1555.34

55.7

192.7

1555.75

56.1

192.65

1556.15

56.5

192.6

1556.96

56.9

192.55

1556.96

B58.1

58.1

192.4

1558.17

58.5

192.35

1558.58

58.9

192.3

1558.98

59.3

192.25

1559.39

59.7

192.2

1559.79

60.2

192.15

1560.20

60.6

192.1

1560.61

61.0

192.05

1561.01


Table B-15 lists AD-4B-xx.x optical specifications.

Table B-15 AD-4B-xx.x Optical Specifications 

Parameter
Note
Condition
Min
Max
Unit

-1 dB bandwidth

All SOP and within whole operating environmental range

COM Rx—Band Tx
Band Rx—COM Tx

3.6

nm

-1 dB bandwidth

All SOP and within whole operating temperature range

COM Rx—Exp Tx
Exp Rx—COM Tx

Refer to Table B-16.

nm

Insertion loss
(drop section)

All SOP and within whole operating environmental range; two connectors included, VOA set at minimum attenuation

COM Rx—Band Tx
30.3/46.1

2.9

dB

COM Rx—Band Tx
34.2/50.1

3.3

dB

COM Rx—Band Tx
38.1/54.1

3.8

dB

COM Rx—Band Tx
42.1/58.1

4.5

dB

Insertion loss
(express section)

All SOP and within whole operating environmental range; two connectors included

Exp Rx—COM Tx

4.9

dB

All SOP and within whole operating environmental range; two connectors included, VOA set at its minimum attenuation

COM Rx—Exp Tx

3

dB

Insertion loss
(add section)

All SOP and within whole operating environmental range; two connectors included

Band Rx 30.3/46.1—COM Tx

3.5

dB

Band Rx 34.2/50.1—COM Tx

2.8

dB

Band Rx 38.1/54.1—COM Tx

2.3

dB

Band Rx 42.1/58.1—COM Tx

1.8

dB

VOA dynamic range

30

dB

Maximum optical input power

300

mW


Table B-16 lists the range of wavelengths for the receive (express) band.

Table B-16 AD-4B-xx.x Transmit and Receive Dropped Band Wavelength Ranges 

Tx (Dropped) Band
Rx (Express) Band
Left Side (nm)
Right Side (nm)

B30.3

Wavelengths 1533.825 or higher

B34.2

Wavelengths 1533.395 or lower

Wavelengths 1537.765 or higher

B38.1

Wavelengths 1537.325 or lower

Wavelengths 1541.715 or higher

B42.1

Wavelengths 1541.275 or lower

Wavelengths 1545.695 or higher

B46.1

Wavelengths 1545.245 or lower

Wavelengths 1549.695 or higher

B50.1

Wavelengths 1549.235 or lower

Wavelengths 1553.705 or higher

B54.1

Wavelengths 1553.255 or lower

Wavelengths 1557.745 or higher

B58.1

Wavelengths 1557.285 or lower


AD-4B-xx.x optical input and output power varies with amplifier output levels and the class of transponder interfaces used. See Table 15-3 on page 15-6 through Table 15-5 on page 15-8 for this information.

The AD-4B-xx.x has the following additional specifications:

Environmental

Operating temperature:

C-Temp: -5 to +55 degrees Celsius (+23 to +131 degrees Fahrenheit)

Operating humidity: Telcordia GR-63 5.1.1.3 compliant; 5 to 95 percent RH

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.92 in. (23.4 mm)

Depth: 9.0 in. (228.6 mm)

B.4.15  32WSS Card Specifications

The 32WSS card optical specifications are listed in Table B-17.


Note For power specifications, see the "15.1.7  Multiplexer, Demultiplexer, and OADM Card Interface Classes" section on page 15-6.


Table B-17 32WSS Optical Specifications 

Parameter
Note
Condition
Min
Typical
Max
Units

-0.25 dB bandwidth

All SOP and within whole operating temperature range, connectors included, and for maximum VOA operating attenuation.

EXP RX => COM TX

+/-/95

pm

-0.5 dB bandwidth

+/-115

pm

-1.0 dB bandwidth

+/-135

pm

-0.25 dB bandwidth

Add 1, 32 => COM TX

+/-115

pm

-0.5 dB bandwidth

+/-135

pm

-1.0 dB bandwidth

+/-160

pm

Insertion loss

All SOP, any optical switch state, and within whole operating temperature range, connectors included.

EXP RX => COM TX

11.3

dB

COM RX => EXP TX

1.5

dB

Add 1, 32 => COM TX

7.6

dB

COM RX => DROP TX

6

8.5

dB

VOA dynamic range

EXP RX => COM TX

20

dB

Add 1, 32 => COM TX

25

dB

Maximum optical input power

300

mW


The 32WSS channel plan is shown in Table B-18. All 32WSS client interfaces must comply with this plan.

.

Table B-18 32WSS Channel Plan 

Channel Number
Band
Channel ID
Frequency (GHz)
Wavelength (nm)

1

1

30.3

195.9

1530.33

2

31.2

195.8

1531.12

3

31.9

195.7

1531.90

4

32.6

195.6

1532.68

5

2

34.2

195.4

1534.25

6

35.0

195.3

1535.04

7

35.8

195.2

1535.82

8

36.6

195.1

1536.61

9

3

38.1

194.9

1538.19

10

38.9

194.8

1538.98

11

39.7

194.7

1539.77

12

40.5

194.6

1540.56

13

4

42.1

194.4

1542.14

14

42.9

194.3

1542.94

15

43.7

194.2

1543.73

16

44.5

194.1

1544.53

17

5

46.1

193.9

1546.12

18

46.9

193.8

1546.92

19

47.7

193.7

1547.72

20

48.5

193.6

1548.51

21

6

50.1

193.4

1550.12

22

50.9

193.3

1550.92

23

51.7

193.2

1551.72

24

52.5

193.1

1552.52

25

7

54.1

192.9

1554.13

26

54.9

192.8

1554.94

27

55.7

192.7

1555.75

28

56.5

192.6

1556.55

29

8

58.1

192.4

1558.17

30

58.9

192.3

1558.98

31

59.7

192.2

1559.79

32

60.6

192.1

1560.61


The 32WSS card has the following additional specifications:

Environmental

Operating temperature:

C-Temp: -5 to +55 degrees Celsius (+23 to +131 degrees Fahrenheit)

Operating humidity: 5 to 95 percent RH

Dimensions

Height: 12.65 in. (321.3 mm)

Width: 1.84 in. (46.8 mm)

Depth: 9.00 in. (228.6 mm)

B.5  Transponder and Muxponder Card Specifications

This section provides specifications for the TXP_MR_10G, MXP_2.5G_10G, TXP_MR_2.5G, TXPP_MR_2.5G, MXP_MR_2.5G, MXPP_MR_2.5G, MXP_2.5G_10E, and TXP_MR_2.5G cards.

For compliance information, refer to the Cisco Optical Transport Products Safety and Compliance Information document.

B.5.1  TXP_MR_10G Card Specifications

The TXP_MR_10G card has the following specifications:

Line (trunk side)

Bit rate:

9.95328 Gbps for OC-192/STM-64

10.70923 Gbps with ITU-T G.709 Digital Wrapper/forward error correction (FEC)

10.3125 Gbps for 10 Gigabit Ethernet (GE)

11.095 Gbps with ITU-T G.709 Digital Wrapper/FEC over 10 GE

Code: Scrambled NRZ

Fiber: 1550-nm single-mode

Maximum chromatic dispersion allowance: 1000 ps/nm

Loopback modes: Terminal and facility


Caution You must use a 15-dB fiber attenuator (10 to 20 dB) when working with the TXP_MR_10G card in a loopback on the trunk port. Do not use direct fiber loopbacks with the TXP_MR_10G card. Using direct fiber loopbacks causes irreparable damage to the TXP_MR_10G card.

Connectors: LC

Compliance Telcordia GR-253-CORE, ITU-T G.707, ITU-T G.691

Transmitter (trunk side)

Maximum transmitter output power: +3.5 dBm

Minimum transmitter output power: +2.5 dBm

Transmitter: Lithium Niobate (LN) external modulator transmitter

Wavelength stability (drift): +/- 25 picometers (pm)


Note An optical device on the card keeps the laser wavelength locked as closely as possible to the ITU nominal value. The allowed drift is +/- 25 pm.


Currently available wavelengths and versions of TXP_MR_10G (16 card versions, each covering two wavelengths):

1530.33 to 1531.12 nm (two wavelengths)

1531.90 to 1532.68 nm (two wavelengths)

1534.25 to 1535.04 nm (two wavelengths)

1535.82 to 1536.61 nm (two wavelengths)

1538.19 to 1538.98 nm (two wavelengths)

1539.77 to 1540.56 nm (two wavelengths)

1542.14 to 1542.94 nm (two wavelengths)

1543.73 to 1544.53 nm (two wavelengths)

1546.12 to 1546.92 nm (two wavelengths)

1547.72 to 1548.51 nm (two wavelengths)

1550.12 to 1550.92 nm (two wavelengths)

1551.72 to 1552.52 nm (two wavelengths)

1554.13 to 1554.94 nm (two wavelengths)

1555.75 to 1556.55 nm (two wavelengths)

1558.17 to 1558.98 nm (two wavelengths)

1559.79 to 1560.61 nm (two wavelengths)

Receiver (trunk side):

Receiver input power (no FEC, unamplified, 23 dB optical signal-to-noise ratio [OSNR], BER 1 * 10 exp - 12): -8 to -21 dBm

Receiver input power (no FEC, unamplified, 23 dB OSNR, at +/- 1000 ps/nm BER 1 * 10 exp - 12): -8 to -19 dBm

Receiver input power (no FEC, amplified, 19 dB OSNR, BER 1 * 10 exp - 12): -8 to -20 dBm

Receiver input power (no FEC, amplified, 19 dB OSNR, at +/- 1000 ps/nm BER 1 * 10 exp - 12):-8 to -18 dBm

Receiver input power (FEC, unamplified, 23 dB OSNR, BER 8 * 10 exp - 5): -8 to -24 dBm

Receiver input power (FEC, unamplified, 23 dB OSNR, at +/- 1000 ps/nm, BER 8 * 10 exp - 5): -8 to -22 dBm

Receiver input power (FEC, amplified, 9 dB OSNR, BER 8 * 10 exp - 5): -8 to -18 dBm

Receiver input power (FEC, unamplified, 11 dB OSNR, at +/- 800 ps/nm, BER 8 * 10 exp - 5): -8 to -18 dBm

Line (client side)

Bit rate: 9.95328 Gbps or 10.3125 Gbps

Code: Scrambled NRZ

Fiber: 1550-nm single-mode

Maximum chromatic dispersion allowance: Compliant with SR-1 specification for OC-192. In the case of 10 GE, the allowance is up to 10 km of single-mode fiber (SMF) dispersion.

Loopback modes: Terminal and facility

Connectors: LC

Compliance: Telcordia GR-253-CORE, ITU-T G.707, ITU-T G.697, 10GEBase-LR

Transmitter (client side)

Maximum transmitter output power: -1 dBm

Minimum transmitter output power: -6 dBm

Center wavelength: 1290 to 1330 nm

Nominal wavelength: 1310 nm

Transmitter: Distributed feedback (DFB) laser

Receiver (client side)

Maximum receiver level: -1 dBm at BER 1 * 10 exp - 12

Minimum receiver level: -14 dBm at BER 1 * 10 exp - 12

Receiver: avalanche photodiode (APD)

Link loss budget: 8 dB minimum, at BER = 1 * 10 exp - 12

Receiver input wavelength range: 1290 to 1605 nm

Environmental

Operating temperature: -5 to +55 degrees Celsius (+23 to +113 degrees Fahrenheit)

Operating humidity: 5 to 95 percent, noncondensing

Power consumption: 35.00 W, 0.73 A at -48 V, 119.5 BTU/hr

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Depth with backplane connector: 9.250 in. (235 mm)

Weight not including clam shell: 3.1 lb (1.3 kg)

B.5.2  MXP_2.5G_10G Card Specifications

The MXP_2.5G_10G card has the following specifications:

Line (trunk side)

Bit rate:

9.95328 Gbps for OC-192/STM-64

10.70923 Gbps with ITU-T G.709 Digital Wrapper/FEC

Code: Scrambled NRZ

Fiber: 1550-nm single-mode

Maximum chromatic dispersion allowance: 1000 ps/nm

Loopback modes: Terminal and facility


Caution You must use a 20-dB fiber attenuator (15 to 25 dB) when working with the MXP_2.5G_10G card in a loopback on the trunk port. Do not use direct fiber loopbacks with the MXP_2.5G_10G card. Using direct fiber loopbacks causes irreparable damage to the MXP_2.5G_10G card.

Connectors: LC

Compliance: Telcordia GR-253-CORE, ITU-T G.707, ITU-T G.691

Transmitter (trunk side)

Maximum transmitter output power: +3.5 dBm

Minimum transmitter output power: +2.5 dBm

Transmitter: LN external modulator transmitter

Wavelength stability (drift): +/- 25 picometers (pm)


Note An optical device on the card keeps the laser wavelength locked as closely as possible to the ITU nominal value. The allowed drift is +/- 25 pm.


Currently available wavelengths and versions of MXP_2.5G_10G (16 card versions, each covering two wavelengths):

1530.33 to 1531.12 nm (two wavelengths)

1531.90 to 1532.68 nm (two wavelengths)

1534.25 to 1535.04 nm (two wavelengths)

1535.82 to 1536.61 nm (two wavelengths)

1538.19 to 1538.98 nm (two wavelengths)

1539.77 to 1540.56 nm (two wavelengths)

1542.14 to 1542.94 nm (two wavelengths)

1543.73 to 1544.53 nm (two wavelengths)

1546.12 to 1546.92 nm (two wavelengths)

1547.72 to 1548.51 nm (two wavelengths)

1550.12 to 1550.92 nm (two wavelengths)

1551.72 to 1552.52 nm (two wavelengths)

1554.13 to 1554.94 nm (two wavelengths)

1555.75 to 1556.55 nm (two wavelengths)

1558.17 to 1558.98 nm (two wavelengths)

1559.79 to 1560.61 nm (two wavelengths)

Receiver (trunk side)

Receiver input power (no FEC, unamplified, 23 dB OSNR, BER 1 * 10 exp - 12): -8 to -21 dBm

Receiver input power (no FEC, unamplified, 23 dB OSNR, at +/- 1000 ps/nm BER 1 * 10 exp - 12): -8 to -19 dBm

Receiver input power (no FEC, amplified, 19 dB OSNR, BER 1 * 10 exp - 12): -8 to -20 dBm

Receiver input power (no FEC, amplified, 19 dB OSNR, at +/- 1000 ps/nm BER 1 * 10 exp - 12):-8 to -18 dBm

Receiver input power (FEC, unamplified, 23 dB OSNR, BER 8 * 10 exp - 5): -8 to -24 dBm

Receiver input power (FEC, unamplified, 23 dB OSNR, at +/- 1000 ps/nm, BER 8 * 10 exp - 5): -8 to -22 dBm

Receiver input power (FEC, amplified, 9 dB OSNR, BER 8 * 10 exp - 5): -8 to -18 dBm

Receiver input power (FEC, unamplified, 11 dB OSNR, at +/- 800 ps/nm, BER 8 * 10 exp - 5): -8 to -18 dBm

Line (client side)

Bit rate: 2.48832 Gbps

Code: Scrambled NRZ

Fiber: 1550-nm single-mode

Maximum chromatic dispersion allowance: Compliant with SR-1 specification for OC-192. In the case of 10 GE, allowance is up to 10 km of SMF fiber of dispersion.

Loopback modes: Terminal and facility

Connectors: LC

Compliance: Telcordia GR-253-CORE, ITU-T G.707, ITU-T G.957

Transmitter (client side): Depends on the Small Form-factor Pluggable (SFP) that is used.

Receiver (client side): Depends on the SFP that is used.

Environmental

Operating temperature: -5 to +55 degrees Celsius (+23 to +113 degrees Fahrenheit)

Operating humidity: 5 to 95 percent, noncondensing

Power consumption: 50.00 W, 1.04 A at -48 V, 170.7 BTU/hr

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Depth with backplane connector: 9.250 in. (235 mm)

Weight not including clam shell: 3.1 lb (1.3 kg)

B.5.3  TXP_MR_2.5G and TXPP_MR_2.5G Card Specifications

The TXP_MR_2.5G and TXPP_MR_2.5G cards have the following specifications:

Line (trunk side)

Bit rate:

2.488 Gbps for OC-48/STM-16

2.66 Gbps with ITU-T G.709 Digital Wrapper/FEC

Code: Scrambled NRZ

Fiber: 1550-nm single-mode

Maximum chromatic dispersion allowance: 5400 ps/nm

Loopback modes: Terminal and facility


Caution You must use a 20-dB fiber attenuator (15 to 25 dB) when working with the TXP_MR_2.5G and TXPP_MR_2.5G cards in a loopback on the trunk port. Do not use direct fiber loopbacks with the TXP_MR_2.5G and TXPP_MR_2.5G cards. Using direct fiber loopbacks causes irreparable damage to the TXP_MR_2.5G and TXPP_MR_2.5G cards.

Connectors: LC

Compliance: Telcordia GR-253-CORE, ITU-T G.707, ITU-T G.957

Transmitter (trunk side)

Maximum transmitter output power: +1 dBm

Minimum transmitter output power: -4.5 dBm

Transmitter: Direct modulated laser

Wavelength stability (drift): +/- 25 picometers (pm)


Note An optical device on the card keeps the laser wavelength locked as closely as possible to the ITU nominal value. The allowed drift is +/- 25 pm.


Currently available wavelengths of TXP_MR_2.5G and TXPP_MR_2.5G (eight card versions):

ITU grid blue band: 1530.334 to 1544.526 nm (four card versions covering four wavelengths each)

ITU grid red band: 1546.119 to 1560.606 nm (four card versions covering four wavelengths each)

Receiver (trunk side)

Table B-19 TXP_MR_2.5G/TXPP_MR_2.5G Receiver Trunk Side Specifications 

OSNR1
FEC Type
Pre-FEC BER
Post-FEC BER
Input Power Sensitivity
Chromatic Dispersion Tolerance

15 dB

Off - 2R

<10 exp - 12

N/A

- 9 to - 24 dBm

15 dB

Off - 2R

<10 exp - 12

N/A

- 9 to - 21 dBm

+/- 3300ps/nm

14 dB

Off - 3R

<10 exp - 12

N/A

- 9 to - 30 dBm

15 dB

Off - 3R

<10 exp - 12

N/A

- 9 to - 30 dBm

+/- 1800ps/nm

16 dB

Off - 3R

<10 exp - 12

N/A

- 9 to - 30 dBm

+/- 5400ps/nm

5 dB

Standard- 3R

<10 exp - 5

<10 exp - 15

- 9 to - 25 dBm

5 dB

Standard- 3R

<10 exp - 5

<10 exp - 15

- 9 to - 24 dBm

+/- 1800ps/nm

5 dB

Standard- 3R

<10 exp - 5

<10 exp - 15

- 9 to - 23 dBm

+/- 5400ps/nm

14 dB

Standard- 3R

<10 exp - 5

<10 exp - 15

- 9 to - 31 dBm

1 Optical Signal-to-Noise ratio (OSNR) defined with 0.5 nm Resolution Bandwidth (RBW)


Receiver: APD

Link loss budget: 24 dB minimum, with no dispersion or 22 dB optical path loss at
BER = 1 * 10 exp - 12 including dispersion

Receiver input wavelength range: 1290 to 1605 nm

Line (client side)

Bit rate: 8 Mbps to 2.488 Gbps

Code: Scrambled NRZ

Fiber: 1310-nm single-mode

Maximum chromatic dispersion allowance: 1600 ps/nm

Loopback modes: Terminal and facility

Connectors: LC

Compliance: Telcordia GR-253-CORE, ITU-T G.707, ITU-T G.957

Transmitter (client side)

Maximum transmitter output power: -1 dBm

Minimum transmitter output power: -6 dBm

Center wavelength: 1290 to 1330 nm

Nominal wavelength: 1310 nm

Transmitter: DFB laser

Receiver (client side)

Maximum receiver level: -1 dBm at BER 1 * 10 exp - 12

Minimum receiver level: -14 dBm at BER 1 * 10 exp - 12

Receiver: APD

Link loss budget: 8 dB minimum, at BER = 1 * 10 exp - 12

Receiver input wavelength range: 1290 to 1605 nm

Environmental

Operating temperature: -5 to +45 degrees Celsius (+23 to +113 degrees Fahrenheit)

Operating humidity: 5 to 95 percent, noncondensing

Power consumption: 35.00 W, 0.73 A at -48 V, 119.5 BTU/hr

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Depth with backplane connector: 9.250 in. (235 mm)

Weight not including clam shell: 3.1 lb (1.3 kg)

B.5.4  MXP_MR_2.5G and MXPP_MR_2.5G Card Specifications

The MXP_MR_2.5G and MXPP_MR_2.5G cards have the following specifications:

Payload configuration

FC1G—Fiber Channel 1.06 Gbps

FC2G—Fiber Channel 2.125 Gbps

FICON1G—Fiber CON 1.06 Gbps (IBM signal)

FICON2G—Fiber CON 2.125 Gbps (IBM signal)

ONE_GE—One Gigabit Ethernet 1.125 Gbps

Mixed configurations up to maximum line rate (for example, if you have a port configured for 2G FC, you cannot use another port at the same time)

Client ports: 8x SFP

Performance monitoring (PM) for all interfaces

Buffer-to-buffer credit management for distance extension

Line (trunk side)

Bit rate: 2.488 Gbps for OC-48/STM-16

Code: Scrambled NRZ

Fiber: 1550-nm single-mode

Maximum chromatic dispersion allowance: 6000 ps/nm

Loopback modes: Terminal and facility


Caution You must use a 20-dB fiber attenuator (15 to 25 dB) when working with the MXP_MR_2.5G and MXPP_MR_2.5G cards in a loopback on the trunk port. Do not use direct fiber loopbacks with the MXP_MR_2.5G and MXPP_MR_2.5G cards. Using direct fiber loopbacks causes irreparable damage to the MXP_MR_2.5G and MXPP_MR_2.5G cards.

Connectors: LC

Compliance: Telcordia GR-253-CORE, Telcordia GR-2918-CORE, Issue 2, ITU-T G.957, and ITU-T 100-GHz grid standard G.692

Transmitter (trunk side)

Transmit power: +3 +/- 1 dBm with MXP_MR_2.5G card, and +/- 1 dBm with MXPP_MR_2.5G card

50-GHz DWDM migration ready (the wavelength deviation is less than +/- 0.040 nm through wavelocker deployment)

Four-channel wavelength tunability at 100-GHz spacing

Transmitter maximum return reflectance: -27 dB

Chromatic dispersion allowance: 5400 ps/nm, giving an optical power penalty < 2.0 dB

Minimum side mode suppression ratio: 30 dB

Transmitter is a direct modulated laser

Wavelength stability (drift): +/- 25 picometers (pm)


Note An optical device on the card keeps the laser wavelength locked as closely as possible to the ITU nominal value. The allowed drift is +/- 25 pm.


Currently available wavelengths of the TXP_MR_2.5G and TXPP_MR_2.5G cards (eight card versions):

ITU grid blue band: 1530.334 to 1544.526 nm (four card versions, four wavelengths each)

ITU grid red band: 1546.119 to 1560.606 nm (four card versions, four wavelengths each)

Receiver (trunk side)

Table B-20 MXP_MR_2.5G/MXPP_MR_2.5G Receiver Trunk Side Specifications 

OSNR1
FEC Type
Pre-FEC BER
Post-FEC BER
Input Power Sensitivity
Chromatic Dispersion Tolerance

10 dB

N/A

<10 exp - 12

N/A

- 9 to - 23 dBm

10 dB

N/A

<10 exp - 12

N/A

- 9 to - 22 dBm

+/- 1800 ps/nm

10 dB

N/A

<10 exp - 12

N/A

- 9 to - 21 dBm

+/- 5400 ps/nm

11 dB

N/A

<10 exp - 12

N/A

- 9 to - 23 dBm

+/- 1800 ps/nm

12 dB

N/A

<10 exp - 12

N/A

- 9 to - 23 dBm

+/- 5400 ps/nm

14 dB

N/A

<10 exp - 12

N/A

- 9 to - 30 dBm

14 dB

N/A

<10 exp - 12

N/A

- 9 to - 29 dBm

+/- 1800 ps/nm

14 dB

N/A

<10 exp - 12

N/A

- 9 to - 28 dBm

+/- 5400 ps/nm

15 dB

N/A

<10 exp - 12

N/A

- 9 to - 30dBm

+/- 1800 ps/nm

16 dB

N/A

<10 exp - 12

N/A

- 9 to - 30dBm

+/- 5400 ps/nm

1 Optical Signal-to-Noise ratio (OSNR) defined with 0.5 nm Resolution Bandwidth (RBW)


Receiver sensitivity -28 dBm, BER 1 * 10 exp - 12

Receiver overload is equal to or exceeds -8 dBm

Receiver maximum reflectance of -27 dB

Line (client side)

Bit rate: 1.06 Gbps to 2.125 Gbps per client

Code: Scrambled NRZ

Fiber: 1310-nm single-mode or 850-nm multimode

Maximum chromatic dispersion allowance: 1600 ps/nm

Loopback modes: Terminal and facility

Connectors: LC

Compliance: Telcordia GR-253-CORE, ITU-T G.707, ITU-T G.957

Transmitter (client side)

Maximum transmitter output power: -1 dBm

Minimum transmitter output power: -6 dBm

Center wavelength: 1290 to 1330 nm

Nominal wavelength: 1310 nm

Transmitter: DFB laser

Receiver (client side)

Maximum receiver level: -1 dBm at BER 1 * 10 exp - 12

Minimum receiver level: -14 dBm at BER 1 * 10 exp - 12

Receiver: APD

Link loss budget: 8 dB minimum, at BER = 1 * 10 exp - 12

Receiver input wavelength range: 1290 to 1605 nm

Environmental

Operating temperature: -5 to +40 degrees Celsius (+23 to +104 degrees Fahrenheit)

Operating humidity: 5 to 85 percent, noncondensing

Power consumption (maximum): 60 W, 1.25 A at -48 V, 204 BTU/hr

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Depth with backplane connector: 9.250 in. (235 mm)

Weight not including clam shell: 2.25 lb (1.02 kg)

B.5.5  MXP_2.5G_10E Card Specifications

The MXP_2.5G_10E card has the following specifications:

Line (trunk side)

Bit rate: 10.70923 Gbps (in ITU-T G.709 Digital Wrapper/FEC mode)

Code: Scrambled NRZ

Fiber: 1550-nm single-mode

Maximum chromatic dispersion allowance: +/- 1200 ps/nm (specified penalty)

Loopback modes: Terminal and facility


Caution You must use a 20-dB fiber attenuator (15 to 25 dB) when working with the MXP_2.5G_10E card in a loopback on the trunk port. Do not use direct fiber loopbacks with the MXP_2.5G_10E card. Using direct fiber loopbacks causes irreparable damage to the MXP_2.5G_10E card.

Connectors: LC

Compliance: ITU-T G.707, ITU-T G.709, ITU-T G.957, and Telcordia GR-253-CORE

Transmitter (trunk side)

Maximum transmitter output power: +6 dBm

Minimum transmitter output power: +3 dBm

Transmitter: LN external modulator transmitter

Wavelength stability (drift): +/- 25 picometers (pm)


Note An optical device on the card keeps the laser wavelength locked as closely as possible to the ITU nominal value. The allowed drift is +/- 25 pm.


Currently available wavelengths and versions of MXP_2.5G_10E (eight card versions):

ITU grid blue band:

1530.33 to 1533.07 nm (four channels)

1534.25 to 1537.00 nm (four channels)

1538.19 to 1540.95 nm (four channels)

1542.14 to 1544.92 nm (four channels)

ITU grid red band:

1546.12 to 1548.92 nm (four channels)

1550.12 to 1552.93 nm (four channels)

1554.13 to 1556.96 nm (four channels)

1558.17 to 1561.01 nm (four channels)

Receiver (trunk side)

Table B-21 MXP_2.5G_10E Receiver Trunk Side Specifications 

OSNR1
FEC Type
Pre-FEC BER
Post-FEC BER
Input Power Sensitivity
Chromatic Dispersion Tolerance

23 dB

Off

<10 exp - 12

N/A

- 8 to - 20 dBm

+/- 1200 ps/nm

19 dB

Off

<10 exp - 12

N/A

- 8 to - 20 dBm

+/- 1000 ps/nm

19 dB

Off

<10 exp - 12

N/A

- 8 to - 22 dBm

10 dB

Standard

<10 exp - 5

<10 exp - 15

- 8 to - 18 dBm

+/- 800 ps/nm

8 dB

Standard

<10 exp - 5

<10 exp - 15

- 8 to - 18 dBm

8 dB

Enhanced

<7 x 10 exp - 4

<10 exp - 15

- 8 to - 18 dBm

+/- 800 ps/nm

7 dB

Enhanced

<7 x 10 exp - 4

<10 exp - 15

- 8 to - 18 dBm

1 Optical Signal-to-Noise ratio (OSNR) defined with 0.5 nm Resolution Bandwidth (RBW)


Receiver: APD

Link loss budget: 24 dB minimum, with no dispersion or 22 dB optical path loss at
BER = 1 * 10 exp - 12 including dispersion

Receiver input wavelength range: 1290 to 1605 nm

Line (client side)

Bit rate: 2.5 Gbps per port (OC-48/STM-16)

Code: Scrambled NRZ

Fiber: 1310-nm single-mode

Maximum chromatic dispersion allowance: 12 ps/nm (SR SFP version)

Loopback modes: Terminal and facility

Connectors: LC (optical)

Compliance: Telcordia GR-253-CORE, ITU-T G.707, ITU-T G.957

Transmitter (client side): Depends on the SFP that is used.

Receiver (client side): Depends on the SFP that is used.

Environmental

Operating temperature: -5 to +55 degrees Celsius (+23 to +113 degrees Fahrenheit)

Operating humidity: 5 to 95 percent, noncondensing

Power consumption: 50.00 W (maximum), 1.11 A at -48 V, 136.6 BTU/hr

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Depth with backplane connector: 9.250 in. (235 mm)

Weight not including clam shell: 3.1 lb (1.3 kg)

B.5.6  TXP_MR_10E Card Specifications

The TXP_MR_10E card has the following specifications:

Line (trunk side)

Bit rate: OC-192/STM-64 (9.95328 Gbps), OTU2 (10.70923 Gbps), 10GE (10.3125 Gbps), 10GE into OTU2 (non-standard 11.0957 Gbps), 10G FC (10.51875 Gbps), or 10G FC into OTU2 (non-standard 11.31764 Gbps)

Code: Scrambled NRZ

Fiber: 1550-nm single-mode

Maximum chromatic dispersion allowance: +/- 1200 ps/nm (specified penalty)

Loopback modes: Terminal and facility


Caution You must use a 15-dB fiber attenuator (10 to 20 dB) when working with the TXP_MR_10E card in a loopback on the trunk port. Do not use direct fiber loopbacks with the TXP_MR_10E card. Using direct fiber loopbacks causes irreparable damage to the TXP_MR_10E card.

Connectors: LC

Compliance: Telcordia GR-253-CORE, ITU-T G.707, ITU-T G.957, and ITU-T G.709

Transmitter (trunk side)

Maximum transmitter output power: +6 dBm

Minimum transmitter output power: +3 dBm for C-band and +2 dBm for L-band

Transmitter: LN external modulator transmitter

Wavelength stability (drift): +/- 25 picometers (pm)


Note An optical device on the card keeps the laser wavelength locked as closely as possible to the ITU nominal value. The allowed drift is +/- 25 pm.


Currently available wavelengths and versions of TXP_MR_10E:

C-band frequency plan (eight card versions, each with four tunable channels on the ITU 100-GHz grid):

1530.33 to 1533.07 nm (four channels)

1534.25 to 1537.00 nm (four channels)

1538.19 to 1540.95 nm (four channels)

1542.14 to 1544.92 nm (four channels)

1546.12 to 1548.92 nm (four channels)

1550.12 to 1552.93 nm (four channels)

1554.13 to 1556.96 nm (four channels)

1558.17 to 1561.01 nm (four channels)

L-band frequency plan (five card versions, each with eight tunable channels on the ITU 50-GHz grid):

1577.44 to 1580.35 nm (eight channels)

1580.77 to 1583.69 nm (eight channels)

1584.11 to 1587.04 nm (eight channels)

1587.46 to 1590.41 nm (eight channels)

1590.83 to 1593.79 nm (eight channels)

Receiver (trunk side)

Table B-22 TXP_MR_10E Receiver Trunk Side Specifications 

OSNR1
FEC Type
Pre-FEC BER
Post-FEC BER
Input Power Sensitivity2
Chromatic Dispersion Tolerance

23 dB

Off

<10 exp - 12

N/A

- 8 to - 20 dBm

+/- 1200 ps/nm

19 dB

Off

<10 exp - 12

N/A

- 8 to - 20 dBm

+ - 1000 ps/nm

19 dB

Off

<10 exp - 12

N/A

- 8 to - 22 dBm

10 dB

Standard

<10 exp - 5

<10 exp - 15

- 8 to - 18 dBm

+/- 800 ps/nm

8 dB

Standard

<10 exp - 5

<10 exp - 15

- 8 to - 18 dBm

8 dB

Enhanced

<7 x 10 exp - 4

<10 exp - 15

- 8 to - 18 dBm

+/- 800 ps/nm

7 dB

Enhanced

<7 x 10 exp - 4

<10 exp - 15

- 8 to - 18 dBm

1 Optical Signal-to-Noise ratio (OSNR) defined with 0.5 nm Resolution Bandwidth (RBW)

2 Receiver filter bandwidth greater than or equal to 180 pm (at - 3 dBm)


Receiver: APD

Link loss budget: 24 dB minimum, with no dispersion or 22 dB optical path loss at
BER = 1 * 10 exp - 12 including dispersion

Receiver input wavelength range: 1290 to 1605 nm

Line (client side):

10-Gigabit Small Form-factor Pluggable (XFP)-based SR

Bit rate: 10GE (10.3125 Gbps), 10G FC (10.51875 Gbps), or STM-64/OC-192

Code: Scrambled NRZ

Fiber: 1310-nm single-mode

Maximum chromatic dispersion allowance: 6.6 ps/nm

Loopback modes: Terminal and facility

Connectors: LC

Compliance: Telcordia GR-253-CORE, ITU-T G.707, ITU-T G.957, ITU-T G.691

Transmitter (client side)

Maximum transmitter output power: -1 dBm

Minimum transmitter output power: -6 dBm

Center wavelength: 1290 to 1330 nm

Nominal wavelength: 1310 nm

Transmitter: DFB laser

Receiver (client side)

Maximum receiver level: -1 dBm at BER 1 * 10 exp - 12

Minimum receiver level: -14 dBm at BER 1 * 10 exp - 12

Receiver: APD

Link loss budget: 8 dB minimum, at BER = 1 * 10 exp - 12

Receiver input wavelength range: 1290 to 1605 nm

Environmental

Operating temperature: -5 to +55 degrees Celsius (+23 to +113 degrees Fahrenheit)

Operating humidity: 5 to 95 percent, noncondensing

Power consumption: 50.00 W (maximum), 1.11 A at -48 V, 136.6 BTU/hr

Dimensions

Height: 12.650 in. (321.3 mm)

Width: 0.716 in. (18.2 mm)

Depth: 9.000 in. (228.6 mm)

Depth with backplane connector: 9.250 in. (235 mm)

Weight not including clam shell: 3.1 lb (1.3 kg)

B.6  SFP Specifications

Table B-23 lists the specifications for available SFPs.

Table B-23 SFP Specifications 

SFP Product ID
Interface
Transmitter Output Power Min/Max (dBm)
Receiver Input Power Min/Max (dBm)

15454-SFP3-1-IR=

OC-3

-15 to -8

-23 to -8

15454E-SFP-L.1.1=

STM-1

-15 to -8

-34 to -10

15454-SFP12-4-IR=

OC-12, D1 Video

-15 to -8

-28 to -7

15454E-SFP-L.4.1=

STM-4, D1 Video

-15 to -8

-28 to -8

15454-SFP-OC48-IR=

OC-48, DV6000 (C-Cor)

-5 to +0

-18 to +0

ONS-SE-2G-S1=

OC-48, STM-16

-10 to -3

-18 to -3

15454E-SFP-L.16.1=

STM-16, DV6000 (C-Cor)

-5 to +0

-18 to 0

15454-SFP-200/
15454E-SFP-200

ESCON1

-20.5 to -15

-29 to -4

15454-SFP-GEFC-SX=/
15454E-SFP-GEFC-S=

Fibre Channel (1 and 2 Gbps), FICON2 , GE

-10 to -3.5

-17 to 0 (1FC and 1GE)

-15 to 0 (2FC)

15454-SFP-GE+-LX=/
15454E-SFP-GE+-LX=

Fibre Channel
(1 and 2 Gbps), FICON, GE, HDTV3

-9.5 to -3.0

-20 to -3 (1FC, 1GE, and 2FC)

ONS-SE-2G-L2

OC-48, STM-16

-2 to 3

-28 to -9

ONS-SE-GE-ZX

Fibre Channel (1 and 2 Gbps), FICON, GE

0 to 5

-25 to 0

1 ESCON = Enterprise System Connection

2 FICON = fiber connectivity

3 HDTV = high-definition television


SFP Port Cabling Specifications

Table B-24 provides cabling specifications for the single-mode fiber (SMF) SFPs and Table B-25 provides cabling specifications for multimode fiber (MMF) SFPs that you install into Ethernet cards. The ports of the listed SFPs have LC-type connectors.

Table B-24 Single-Mode Fiber SFP Port Cabling Specifications 

SFP Product ID
Wavelength1
Fiber Type
Cable Distance

15454-SFP3-1-IR=
Intermediate Reach

1310 nm

9 micron SMF

15 km (9.3 miles)

15454E-SFP-L.1.1=
Short Haul

1310 nm

9 micron SMF

15 km (9.3 miles)

15454-SFP12-4-IR=
Intermediate Reach

1310 nm

9 micron SMF

15 km (9.3 miles)

15454E-SFP-L.4.1=
Short Haul

1310 nm

9 micron SMF

15 km (9.3 miles)

15454-SFP-OC48-IR=
Intermediate Reach

1310 nm

9 micron SMF

15 km (9.3 miles)

ONS-SE-2G-S1=
Short Reach

1310 nm

9 micron SMF

2 km (1.2 miles)

15454E-SFP-L.16.1=
Short Haul

1310 nm

9 micron SMF

15 km (9.3 miles)

15454-SFP-GE+-LX=/
15454E-SFP-GE+-LX=
Long Reach

1310 nm

9 micron SMF

10 km (6.2 miles) for FC 1G, FC 2G, and GE
5 km (3.1 miles) for HDTV

1 Typical loss on a 1310 nm wavelength is 0.6 dB/km.


Table B-25 Multimode Fiber SFP Port Cabling Specifications 

SFP Product ID
Wavelength
Fiber Type
Cable Distance

15454-SFP-200/
15454E-SFP-200
Long Reach

1310 nm

62.5 micron MMF

2 km (1.2 miles)

15454-SFP-GEFC-SX/
15454E-SFP-GEFC-S
Short Reach

850 nm

62.5 micron MMF

300 m (984 ft) for FC 1 Gbps and 1.2 Gbps GE
150 m (492 ft) for FC 2 Gbps

50.0 micron MMF

550 m (1804 ft) for FC 1 Gbps and 1.2 Gbps GE
300 m (984 ft) for FC 2 Gbps


B.7  XFP Specifications

Table B-26 lists the specifications for available XFPs.

Table B-26 XFP Specifications 

XFP Product ID
Interface
Transmitter Output Power Min/Max (dBm)
Receiver Input Power Min/Max (dBm)

ONS-XC-10G-S1

10 Gigabit Ethernet, OC-192, STM-64, 10Gbps Fibre Channel

-1 to -11

0.5


B.7.1  XFP Port Cabling Specifications

Table B-27 provides cabling specifications for the SMF XFPs. The ports of the listed XFPs have LC-type connectors.

Table B-27 Single-Mode Fiber XFP Port Cabling Specifications 

XFP Product ID
Wavelength1
Fiber Type
Cable Distance

ONS-XC-10G-S1

1310 nm

SMF

10 km (6.2 miles)

1 Typical loss on a 1310 nm wavelength is 0.6 dB/km.



hometocprevnextglossaryfeedbacksearchhelp

Posted: Tue Oct 9 08:48:24 PDT 2007
All contents are Copyright © 1992--2007 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.