TL1 Alarms and Errors

7.1 Alarms

7.1.1 AIP

7.1.2 BITS

7.1.3 BPLANE

7.1.4 DS1

7.1.5 DS3

7.1.6 ECN

7.1.7 ENV

7.1.8 EQPT

7.1.9 ETHER

7.1.10 EXTSYNCH

7.1.11 FAN

7.1.12 HDGE (G1000)

7.1.13 NE

7.1.14 NERING

7.1.15 NESYNCH

7.1.16 OCN

7.1.17 STSMON

7.1.18 STSTERM

7.1.19 VT-MON

7.1.20 VT-TERM

7.2 Errors

7.2.1 Errors Listed by Error Code

7.2.2 Errors Listed by Command

7.3 Echo


TL1 Alarms and Errors


This chapter provides TL1 alarm and error information supported by the Cisco ONS 15454 and Cisco ONS 15327, including:

Alarms

Errors

Echo

Each alarm includes a description and severity. Errors are listed by error type and command and include error type and error message. For a list of TL1 conditions, see Table 4-54.

7.1 Alarms

Refer to "Alarm Troubleshooting" in the Cisco ONS 15454 Troubleshooting Guide and in the Cisco ONS 15327 User Documentation for complete alarm definitions, trouble notifications, and fault recovery procedures. The alarms are listed alphabetically by alarmable object:

AIP

FAN

BITS

HDGE (G1000)

BPLANE

NE

DS1

NESYNCH

DS3

OCN

ECN

STSMON

ENV

STSTERM

EQPT

VT-MON

ETHER

VT-TERM

EXTSYNCH

 

For a sample of each TL1 alarm that can be generated by the ONS 15454, refer to the file 15454_r340_tl1_alarms.txt on the Cisco ONS 15454 Software CD in the subdirectory \Tl1. For a sample of each TL1 alarm that can be generated by the ONS 15327, refer to the file 15327_r340_tl1_alarms.txt on the Cisco ONS 15327 Software CD in the subdirectory \Tl1. These files can be used to test an operations support system's ability to receive alarms which the ONS 15454/ONS 15327 can raise.

7.1.1 AIP

Auxiliary interface protection module

Table 7-1 AIP

AIP Alarm
Severity (Active)
Description

INVMACADR

MJ/NSA

The ONS 15454/15327 media access control layer address (MAC address) is invalid.

MEA

CR/SA

The mismatch between entity/equipment type and provisioned attributes alarm occurs when the physical card inserted in a slot does not match the card type that is provisioned for that slot in the CTC.

MFGMEM

CR/SA

The manufacturing data memory failure alarm means that the ONS 15454/15327 cannot access the data on the erasable programmable read-only memory (EPROM).


7.1.2 BITS

Building integration timing supply (BITS) incoming references (BITS-1, BITS-2)

Table 7-2 BITS

BITS Alarm
Severity (Active)
Description

LOF

MJ/SA

A port on the TCC/MIC BITS input detects a loss of frame (LOF) on the incoming BITS timing reference signal.

LOS

MJ/SA

The TCC/MIC card has a loss of signal (LOS) condition from the BITS timing source.

SSM-FAIL

MN/NSA

Synchronization status messaging failed.


7.1.3 BPLANE

The backplane

Table 7-3 BPLANE

BPLANE Alarm
Severity (Active)
Description

MEA

CR/SA

The Mismatch Of Equipment and Attributes (MEA) alarm for the backplane means that the revision of the backplane is incompatible with XC10G equipment.

MFGMEM

CR/SA

The manufacturing data memory failure alarm means that the ONS 15454/15327 cannot access the data on the erasable programmable read-only memory (EPROM).


7.1.4 DS1

A DS1 line on a DS1 or DS3XM card

Table 7-4 DS1

DS1 Alarm
Severity (Active)
Description

LOF

MJ/SA

The receiving ONS 15454/15327 has lost frame delineation in the incoming data.

LOS

MJ/SA

A loss of signal (LOS) at the card for either a DS-3 port or a DS-1 port.

RCVR-MISS

MJ/SA

The facility termination equipment detects a missing receive cable on the DS-1 port or a possible mismatch of backplane equipment.

TRMT

MJ/SA

There is a transmission failure on the DS-1 card due to an internal hardware failure.

TRMT-MISS

MJ/SA

The facility termination equipment detects a missing transmit cable on the DS-1 port or a possible mismatch of backplane equipment.


7.1.5 DS3

A DS3 line on a DS3 or DS3XM card

Table 7-5 DS3

DS3 Alarm
Severity (Active)
Description

LOF

CR/SA

The receiving ONS 1545415327 has lost frame delineation in the incoming data.

LOS

CR/SA

Loss of signal at the card for either a DS-3 port or a DS-1 port.


7.1.6 ECN

An EC1 line on an EC1 card

Table 7-6 ECN

ECN Alarm
Severity (Active)
Description

LOF (EC1-12)

CR/SA

The receiving ONS 15454 has lost frame delineation in the incoming data.

LOS (EC1-12)

CR/SA

A port on the reporting EC-1 card has a loss of signal condition. A SONET receiver detects an all-zero pattern for 10 microseconds or longer.


7.1.7 ENV

An environmental alarm port on an AIC card (ONS 15454) or MIC card (ONS 15327)

Table 7-7 ENV

ENV Alarm
Severity (Active)
Description

EXT

MN/NSA

A facility alarm is detected external to the node because an environmental alarm is present.


7.1.8 EQPT

A card in any of the card slots. This object is used for alarms that refer to the card itself and all other objects on the card including ports, lines, STS and VT.

Table 7-8 EQPT 

EQPT Alarm
Severity (Active)
Description

AUTORESET

MN/NSA

The card is performing a warm reboot automatically.

BKUPMEMP

CR/NSA

A problem with the TCC/XTC card's flash memory.

CARLOSS

MN/NSA

The Ethernet card has lost its link and is not receiving any signal, even an invalid one.

COMIOXC

CR/SA

The IO Slot To XCON Communication Failure alarm is raised by the XC card. It occurs when there is a communication failure for a particular IO slot.

CONTBUS-A-18

MJ/NSA

The main processor on the TCC/XTC card in Slot 7/Slot 5 has lost communication with the coprocessor on the second TCC/XTC card in Slot 11/Slot 6.

CONTBUS-A

MJ/NSA

The TCC/XTC card in Slot 7/Slot 5 has lost communication with a line card.

CONTBUS-B-18

MJ/NSA

The main processor on the TCC/XTC card in Slot 11/Slot 6 has lost communication with the coprocessor on the TCC/XTC card in Slot 7/Slot 5.

CONTBUS-B

MJ/NSA

The TCC/XTC card in Slot 11/Slot 6 has lost communication with a line card.

CTNEQPT-PBPROT

CR/SA

A failure of the main payload between the protect cross-connect (XC/XCVT/XC10G) card in Slot 10, or the protect XTC card, and the reporting traffic card.

CTNEQPT-PBWORK

CR/SA

The main payload bus between the active cross-connect (XC/XCVT/XC10G) card in Slot 8, or the active XTC card, and the reporting traffic card.

EQPT

CR/SA

A hardware failure occurred on the reporting card.

EXCCOL

MN/NSA

There are too many collisions are occurring on the network management LAN.

HITEMP

MN/NSA

The temperature of the ONS 15454/ONS 15327 is above 50 degrees Celsius.

IMPROPRMVL

CR/SA

A card was physically removed from its slot before the card was deleted in CTC.

MEA

CR/SA

The mismatch between entity/equipment type and provisioned attributes alarm occurs when the physical card inserted in a slot does not match the card type that is provisioned for that slot in the CTC.

MEM-GONE

MJ/NSA

Data generated by software operations exceeds the memory capacity of the TCC/XTC card.

MEM-LOW

MN/NSA

Data generated by software operations is close to exceeding the memory capacity of the TCC/XTC card.

PEER-
NORESPONSE

MJ/NSA

The switch agent raises a Peer Card Not Responding alarm if either I/O card in a protection group does not receive a response to the peer status request message.

PROTNA

MN/NSA

The Protection Unit Not Available is raised by an out-of-service protection when a card or port that is provisioned as part of a protection group is not available.

SFTWDOWN-FAIL

MN/NSA

The software download from the TCC/XTC card to the ONS 15454 failed.

SNTP-HOST

MN/NSA

An ONS node serving as an IP proxy for the other ONS nodes in the ring is not forwarding SNTP information to the other ONS nodes in the network.

SWMTXMOD

CR/SA

Traffic on the reporting card is lost when this failure occurs.


7.1.9 ETHER

Ethernet

Table 7-9 EHTER

EHTER Alarm
Severity (Active)
Description

CARLOSS

MJ/SA

A Carrier Loss on the LAN alarm occurs when the ONS 15454 and the workstation hosting CTC do not have a TCP/IP connection.


7.1.10 EXTSYNCH

BITS outgoing references (SYNC-BITS1, SYNC-BITS2)

Table 7-10 EXTSYNCH

EXTSYNCH Alarm
Severity (Active)
Description

SYNCPRI

MN/NSA

A loss of the primary timing source (reference 1).

SYNCSEC

MN/NSA

A loss of the secondary timing source (reference 2).

SYNCTHIRD

MN/NSA

A loss of the third timing source (reference 3).


7.1.11 FAN

Fan-tray assembly

Table 7-11 FAN 

FAN Alarm
Severity (Active)
Description

EQPT-MISS

CR/SA

Indicates the replaceable fan tray assembly unit is missing or not fully inserted.

FAN

CR/SA

A problem with the fan-tray assembly.

FANDEGRADE

MJ/NSA

The Partial Fan Failure alarm is raised if fan speed in shelf fan tray 1, 2, or 3 falls below 500 RPM when read by a tachometry counter.

MEA

CR/SA

The mismatch between entity/equipment type and provisioned attributes alarm occurs when the physical card inserted in a slot does not match the card type that is provisioned for that slot in the CTC.

MFGMEM

CR/SA

The manufacturing data memory failure alarm means that the ONS 15454/ONS 15327cannot access the data on the erasable programmable read-only memory (EPROM).


7.1.12 HDGE (G1000)

High Density Gigabit Ethernet. Applies to G1000 cards.

Table 7-12 HDGE (G1000)

NE Alarm
Severity (Active)
Description

CARLOSS

MJ/SA

A carrier loss on the LAN is the data equivalent of a SONET LOS alarm. The Ethernet card has lost its link and is not receiving a valid signal.

TPTFAIL

MJ/SA

Indicates a break in the end-to-end Ethernet link integrity feature of the G1000-4 cards. This alarm indicates a far-end condition and not a problem with the port reporting TPTFAIL.

UNEQ-P

CR/SA

A Signal Label Mismatch Failure Unequipped Path alarm occurs when the path does not have a valid sender. The UNEQ-P indicator is carried in the C2 signal path byte in the SONET overhead.


7.1.13 NE

The entire network element (SYSTEM)

Table 7-13 NE 

NE Alarm
Severity (Active)
Description

DATAFLT

MN/NSA

The database exceeded the capacity of the flash memory on the TCC/XTC.

EHIBATVG-A

MJ/SA

The voltage level on battery lead A exceeds -56.7 Vdc. (ONS 15454)

EHIBATVG-B

MJ/SA

The voltage level on battery lead B exceeds -56.7 Vdc. (ONS 15454)

ELWBATVG-A

MJ/SA

The voltage on battery feed A is extremely low or has been lost, and power redundancy is no longer guaranteed. (ONS 15454)

ELWBATVG-B

MJ/SA

The voltage on battery feed B is extremely low or has been lost, and power redundancy is no longer guaranteed. (ONS 15454)

HITEMP

CR/SA

The temperature of the ONS 15454/ONS 15327 is above 50 degrees Celsius (122 degrees Fahrenheit).

PRC-DUPID

MJ/SA

Two identical node IDs exist in the same ring.

PWR-A

MJ/SA

This alarm applies to the NE rack. It is raised when there is no power supplied to the main power connector or if power is connected to the backup power connector (Connector B) but not to Connector A. (ONS 15454)

PWR-B

MJ/SA

This alarm applies to the NE rack. It is raised when there is no power supplied to the backup power connector or if power is connected to the main power connector (Connector A) but not to Connector B. (ONS 15454)

RING-MISMATCH

MJ/SA

The Ring ID of the ONS 15454/ONS 15327that is reporting the alarm does not match the Ring ID of another ONS node in the BLSR.

SNTP-HOST

MN/NSA

The SNTP (Simple Network Timing Protocol) host failure alarm indicates that an ONS node serving as an IP proxy for the other ONS nodes in the ring is not forwarding SNTP information to the other ONS nodes in the network.

SYSBOOT

MJ/SA

New software is booting on the TCC/XTC card.


7.1.14 NERING

Represents the ring status of the NE

Table 7-14 NERING

NERING Alarm
Severity (Active)
Description

BLSROSYNC

MJ/SA

The BLSR Out Of Sync alarm occurs when the mapping table needs updating.

PRC-DUPID

MJ/SA

The Procedural Error Duplicate Node ID alarm indicates that two identical node IDs exist in the same ring. The ONS 15454/ONS 15327 requires each node in the ring to have a unique node ID.

RING-MISMATCH

MJ/SA

A Procedural Error Mismatch Ring alarm occurs when the ring ID of the ONS 15454 that is reporting the alarm does not match the ring ID of another ONS node in the BLSR


7.1.15 NESYNCH

Represents the timing status of the NE

Table 7-15 NESYNCH

NESYNCH Alarm
Severity (Active)
Description

FRNGSYNC

MJ/SA

The reporting ONS 15454/ONS 15327 is in free run synchronization mode.

FSTSYNC

MN/NSA

A fast start synchronization. The ONS 15454/ ONS 15327 is choosing a new timing reference.

HLDOVRSYNC

MJ/SA

A loss of primary/secondary timing reference.

SYNCPRI

MN/NSA

A loss of the primary timing source (reference 1).

SYNCSEC

MN/NSA

A loss of the secondary timing source (reference 2).

SYNCTHIRD

MN/NSA

A loss of the third timing source (reference 3).


7.1.16 OCN

An OCN line on an OCN card

Table 7-16 OCN 

OCN Alarm
Severity (Active)
Description

APSB

MN/NSA

The line terminating equipment detects protection switching byte failure in the incoming automatic protection switching (APS) signal if an inconsistent APS byte or invalid code is detected.

APSCDFLTK

MN/NSA

A BLSR is not properly configured.

APSC-IMP

MN/NSA

Invalid K bytes.

APSCINCON

MN/SA

The SONET overhead contains K1/K2 APS bytes that notify receiving equipment, such as the ONS 15454/ONS 15327, to switch the SONET signal from a working to a protect path.

APSCM

MJ/SA

The ONS 15454/ONS 15327 expects a working channel but receives a protection channel.

APSCNMIS

MJ/SA

The node ID contained in the K2 byte of the APS channel being received is not present in the ring map.

APSMM

MN/NSA

There is a mismatch of the protection switching schemes at the two ends of the span.

AUTOLSROFF

CR/SA

The OC-192 card temperature exceeds 90 degrees Centigrade. The internal equipment automatically shuts down the OC-192 laser when the card temperature rises to prevent the card from self-destructing.(ONS 15454)

EOC

MJ/NSA

The ONS 15454/ONS 15327 has lost its data communications channel (DCC).

E-W-MISMATCH

MJ/SA

Nodes in a ring have an east slot/port misconnected to another east slot/port or a west slot/port misconnected to another west slot/port.

FEPRLF

MN/NSA

An automatic protection switching channel failure on a signal coming into the node.

LOF

CR/SA

A port on the reporting OC-N card has an LOF condition.

LOS

CR/SA

A port on the reporting OC-N card has a LOS condition.

SSM-FAIL

MN/NSA

Synchronization status messaging received by the ONS 15454/ONS 15327 failed


7.1.17 STSMON

STS alarm detection at the monitor point (upstream of cross-connect)

Table 7-17 STSMON

STSMON Alarm
Severity (Active)
Description

CONCAT

CR/SA

The transmitted STSc circuit is smaller than the provisioned STSc causing a mismatch of the circuit type on the concatenation facility.

LOP-P

CR/SA

A loss of pointer (LOP) condition at the path level.

PLM-P

CR/SA

A signal label mismatch failure (SLMF).

TIM-P

MN/SA

The expected path trace string does not match the received path trace string.

UNEQ-P

CR/SA

The path does not have a valid sender.


7.1.18 STSTERM

STS alarm detection at termination (downstream of cross-connect)

Table 7-18 STSTERM

STSTERM Alarm
Severity (Active)
Description

LOP-P

CR/SA

A loss of pointer (LOP) condition at the path level.

PLM-P

CR/SA

A signal label mismatch failure (SLMF).

TIM-P

MN/SA

The expected path trace string does not match the received path trace string. Path trace mode can be set to auto or manual for this alarm to occur.

UNEQ-P

CR/SA

The path does not have a valid sender.


7.1.19 VT-MON

VT1 alarm detection at the monitor point (upstream of cross-connect)

Table 7-19 VT-MON

VT-MON Alarm
Severity (Active)
Description

AUTOSW-LOP

MN/SA

Automatic UPSR protection switching took place because of an LOP alarm.

AUTOSW-
UNEQ

MN/SA

Automatic UPSR protection switching took place because of an UNEQ alarm.

LOP-V

MJ/SA

A loss of pointer at the VT level.

UNEQ-V

MJ/SA

The node is receiving SONET path overhead with bits 5, 6 and 7 of the V5 overhead byte all set to zeroes. The failure has occurred at the VT layer.


7.1.20 VT-TERM

VT1 alarm detection at termination (downstream of cross-connect)

Table 7-20 VT-TERM

VT-TERM Alarm
Severity (Active)
Description

LOP-V

MJ/SA

A loss of pointer at the VT level.

PLM-V

MN/SA

The content of the V5 byte in the SONET overhead is inconsistent or invalid.

UNEQ-V

MJ/SA

The node is receiving SONET path overhead with bits 5, 6 and 7 of the V5 overhead byte all set to zeroes. The failure has occurred at the VT layer.


7.2 Errors

Errors may be generated by any command or command response message. You can find errors listed by error code in Table 7-21 and listed by command in Table 7-22. The format of an error message is as follows:

SID DATE TIME
M CTAG DENY
<ERRCDE>
/* <ERRMSG> */
;

7.2.1 Errors Listed by Error Code

Table 7-21 Errors Listed by Error Code 

Error Code
Error Message

ENEQ

Control Not Provisioned
Environmental Control Interface Not Found
Equipment Not Found
Equipment Not Provisioned
Internal Communication Error
Sensor Interface Not Found

IBEX

Invalid AID Block. Extra Datablock
Invalid Payload Block. Extra Datablock
Invalid Payload Block. Extra Parameters

ICNV

Equipment Does Not Match Request
Equipment In Use
Invalid Command
Operation not supported by this card
Performance Monitoring Type Not Supported

IDMS

Missing Internal Data

IDNC

Invalid Data
Invalid PST Value
Invalid SST Value
Primary Source Cannot be Internal When Secondary Source Is Not Internal
Primary Source Cannot be Internal When Third Source Is Not Internal
Secondary Source Cannot be Internal When Third Source Is Not Internal

IDNV

2F-BLSR Architecture Does Not Permit Manual/Forced Span Switching
At least an XC10G XC card is needed for this equipment type
Cannot Change Protection Type
Command Not Valid On Protect Card
Facility Loopback Not Supported
Frame Format Not Supported On Equipment
Frame Format Contains Invalid Data
Incompatible Protect Slot For Protection
Incompatible Equipment Type
Incompatible Equipment Type For Protection
Invalid Data For 2F-BLSR
Invalid Ethernet Frame Size
Invalid Equipment Type
Invalid Log Name
Invalid MONLEV Value
Invalid MONTYPE Value
Invalid Protection Group Card Slot Identifier
Invalid Protid
Invalid Reference
Invalid TAP Number
Invalid Time/Date Interval
Line Code Not Supported
Multiple AIDs Not Allowed
Multiple Protection Group Card Slot Identifiers Not Allowed
Multiple References Not Allowed
Protect Card Does Not Support Protection Type
Protect Slot Not Provisioned
Protection Group Card Slot Identifier Field Required
Protection Group Does Not Exist
Ring Lockout BLSR Switching Is Not Supported
Switch Type Is Not Allowed On 1+1

IDRG

Difference Value Range Error
Invalid PJMON Value
Invalid Threshold Value

IIAC

AID Validation Failed
ALL, Ranging and Grouping Are Not Supported
Cannot Access 1+1 Protect Line
Cannot Make Changes To Protect Card
Equipment Does Not Match Request
Expected Trace Not Supported On This Card Type
Expected Trace String Exceeds Maximum Length (62)
Incoming Trace Not Supported On This Card Type
Incorrect Card Type
Input, Invalid Access
Invalid AID
Invalid AID Pair
Invalid DS1 AID
Invalid Facility AID
Invalid From AID
Invalid G1000 Facility Port
Invalid Month Or Day
Invalid Operation On Drop AID
Invalid PJMON Value
Invalid Protect AID
Invalid Protect AID Or Working AID
Invalid Protect Switching Operation
Invalid Reference
Invalid TAP
Invalid Time
Invalid To AID
Invalid Year
List AID Not Allowed For ALL AID
List Or All AID Not Supported
Multiple AIDs Not Supported
Multiple TAP AIDs Not Supported
Not Allowed On 1+1 Protect Line
Not Allowed On BLSR Protect Line
Only CCT=2WAY Is Allowed When A G1000-4 Port Is Used
Optional AIDs Are Not Supported
RingId Does Not Match with AID Number
Trace Mode Not Supported On This Card Type
Trace Not Supported On This Card Type
Trace String Exceeds Maximum Length (62)
UPSR Cross-Connections Are Not Allowed When A G1000 Port Is Used

IICM

Input, Invalid MOD1
Input, Invalid VERB

IICT

Invalid Correlation Tag

IIDT

Cannot Activate To Older Software
Cannot Revert From R2 To R1
Command Already In Progress
Duplicate Performance Monitoring Schedule
Flash Manager Not Active
Hostname Missing In FTP URL
Invalid Command Mode Value
Invalid Data Parameter
Invalid Location Value
Invalid Revertive Time
Invalid Software Switch Type
Invalid State Value
Mandatory FTP URL Not Provided
Maximum Performance Monitoring Schedule Limit Reached
Memory Out of Range
Null Outputs In FTP URL Parsing
Only NORM CMD_MODE Is Supported
Only OOS PST Is Supported
Only SWDL Is Supported For The xfertype Argument
Package Name Missing in FTP URL
Password Missing In FTP URL
Performance Monitoring Schedule Does Not Exist
Software Activate/Revert Failed
Software Not Available For Switch
Unknown Error Processing FTP URL
Username Missing In FTP URL
ftp:// Missing In FTP URL

IIFM

Invalid Payload Block. Invalid Data Format

IISP

Input, Garbage

IITA

Input, Invalid Target Identifier

INUP

External Ring ID Configuration Not Supported
General Block Unsupported
Node ID Configuration Not Supported
RNGWTR Configuration Not Supported
Ring ID Configuration Not Supported
Ring Map Auto Configuration Not Supported

IPEX

Invalid Payload Block. Extra Parameters

IPMS

Invalid AID Block. Missing Mandatory Field
Invalid Payload Block. Missing Mandatory Field

IPNC

Cannot Change Existing Protection Type
Description Cannot Have More Than 64 Characters
Invalid Flow Control Value
Invalid Maximum Frame Size
Invalid Parameter
Invalid Primary State
Parameters Are Not Consistent
Parameters Not Compatible

IPNV

AID Or Condition Must Be Specified
Cannot Set Expected Path Trace In Auto Mode
Cross-Connection Does Not Have UPSR Path Selector
Invalid Switch Type
Exercise Is Not Allowed On Protected Facility
Far End Performance Monitoring Values Not Supported
INT Not Valid For BITS-OUT
Internal-Ip Lookup Failed
Internal-Network Nodes Lookup Failed
Invalid Clock Source
Invalid Default Router Address
Invalid IIOP Port number
Invalid IP Address
Invalid Parameter
Invalid IP Configuration Parameter
Invalid IP Configuration, Subnets Differ
Invalid IP Mask
Invalid Parameter
Invalid Payload Block. Empty Parameter
Invalid SNTP Host Address
Invalid Switch Command For Synchronization
Invalid Switch Type
New Source Must Be Specified
Node Name Exceeds Maximum Length (62)
PM Not Supported
Primary Reference Incompatible With Timing Mode
Reference Type Not Supported
SPNWTR Parameter Not Supported
TMGREF Parameter Not Supported
Third Reference Incompatible With Timing Mode
Timing Mode Not Compatible

PICC

AID Required
Invalid User Access Privilege Value
Invalid User Identifier-Must Conform To TL1 Rules
Invalid User Password-Must Conform To TL1 Rules
Logout failed
New Password Same As Old Password
Unknown CORBA Exception (Internal Error)
Unknown User
User Access Privilege Required
User Already Exists
User Identifier Exceeds Maximum Length Allowed
User Not Authorized
User Password and User Identifier Cannot Be Identical
User Password Required

PIMA

Memory Out Of Range

PIUC

Cannot Delete The Logged In User
Login Failed
User Currently Logged Into Another Session
User Is Not Superuser
User Not Allowed To Change User Access Privilege
User Not Allowed To Change User Password

RRNG

Invalid Slot Number

RTBY

Connection In Service
TAP Already In Use
TAP Number In Use

RTEN

Cannot Access VT
Cannot Change Access Mode
Cannot Set Access Mode
Invalid Access Mode
Invalid TAP AID
Invalid TAP Mode
Invalid TAP Number
Requested TAP Does Not Exist
TAP Not Found

SAAL

Already Allowed

SAAS

Equipment Already Provisioned
Equipment Not Supported

SADC

TAP Not Connected

SAIN

Already Inhibited

SAIS

Port Already In Service

SAMS

Already In Clear Maintenance State
Already In Force Maintenance State
Already In Lockout Maintenance State
Already In Manual Maintenance State

SAOP

Control Already Operated
Control Not Operated Or Already Released

SAOS

Port Already In OOS-AINS
Port Already In OOS-MT
Port Already Out Of Service

SCAT

STS Is Already Connected
Test Access Busy
VT In Use
VT Is Already Connected

SDBE

AID Parser Failed
Cannot Access Conditions
Cannot Access Controls
Cannot Access Date/Time
Cannot Access Defaults Description
Cannot Access Environmental Settings
Cannot Access Equipment
Cannot Access Facility
Cannot Access IP Configuration
Cannot Access Interface
Cannot Access Node ID
Cannot Access Object
Cannot Access Orderwire
Cannot Access Protection Group
Cannot Access Protection State
Cannot Access SNTP Host
Cannot Access STS
Cannot Access Software Version
Cannot Access Synchronization Configuration
Cannot Access Timezone
Cannot Access VT
Cannot Access VT Performance Monitoring Parameters
Cannot Create 1+1 Protection Group
Cannot Edit STS
Cannot Get Line Information
Cannot Get Synchronization Configuration
Cannot Set Date
Cannot Set Date When Using SNTP
Cannot Set IP Configuration
Cannot Set Node Name
Cannot Set Pointer Justification Monitoring Parameter (PJMON)
Cannot Set SNTP Host Configuration
Cannot Set Timezone
Cannot Switch To E2 Byte With Express Orderwire IS
Card Type Not Supported
Delete Protection Group Failed
Equipment Not Found
Facility Does Not Exist
Facility Does Not Match Request
Facility Is Not Provisioned
File Transfer In Progress
Incompatible Parameter Values
Incorrect Facility Type
Internal Access Failed
Internal Database Error
Invalid DCC
Invalid Performance Monitoring Mode
Invalid Protection Group

   

SDBE (continued)

Location Value Invalid
Object Not Provisioned
Operation Not Supported On EC1 Interface
STS Not Provisioned
Synchronization Configuration Not Available
Synchronization Status Messaging (SSM) Not Supported On EC1 Interface
Used Frame Format Does Not Support Synchronization Status Messaging (SSM)
VT Not Provisioned

SDLD

Duplex Unit Locked

SDNA

Standby TCC Not Ready

SNCC

Replace This Message When A SNCC message is needed

SNCN

Bad Quality Of Clock Source
Cannot Switch To Inferior Reference Source
Clock Source Failed
Command Not Implemented
Cross-Connection Type Not Supported In TL1
Invalid Clock Source
STS Rate Changing Not Supported
This Direction Is Not Supported

SNNS

Reference Not From Optical Card

SNPR

Cannot Get Role Of Port

SNVS

Already Switched To Internal Reference Source
BLSR East Operation Already Set
BLSR West Operation Already Set
Cannot Manually Switch To Active Timing Source
Cannot Operate Loopback In Current State
Facility Not Part Of BLSR
Invalid Admin State
Invalid AINS Soak Time
Invalid BLSR Element
Invalid Clock Source
Invalid Equipment State
Loopback Already In Progress
Loopback Not In Progress
No Switch In Progress
Protection Group Does Not Exist
Protection Unit Active
Working Unit Already Active
Working Unit Already Standby

SOSE

Unrecognized Message Type

SPFA

Cannot Get Current Card Status
Protection Unit Failed Or Missing

SPLD

Cannot Create 1+1 Protection Group
Cannot Delete Equipment
Equipment In Use
Facility Is Busy
Protection Unit Locked

SRCN

Already In Requested Mode
Requested Condition Already Exists

SROF

1+1 Protection Group Not Found
Alarm Log Empty
All DCCs In Use
Cannot Access 1+1 Line
Cannot Access 1+1 Protected Line
Cannot Access 2 Fiber BLSR
Cannot Access 4 Fiber BLSR East Protection
Cannot Access 4 Fiber BLSR West Protection
Cannot Access 4F BLSR
Cannot Access Alarm Log
Cannot Access BLSR
Cannot Access BLSR 2 Wire Line
Cannot Access Cross-Connection
Cannot Access DCC
Cannot Access Facility
Cannot Access Performance Monitoring Mode
Cannot Access Performance Monitoring Statistics
Cannot Access Protected Equipment
Cannot Access Protection Group
Cannot Access Protection Group Information
Cannot Access Protection Group Name
Cannot Access Protection Group Reversion Information
Cannot Access STS
Cannot Access TAP
Cannot Access Unprotected Line
Cannot Access VT
Cannot Change XTC Protection Group
Cannot Create Cross-Connection Between Incompatible Interfaces
Cannot Create Protection Group
Cannot Create TAP
Cannot Delete Cross-Connection
Cannot Delete Protected Equipment
Cannot Delete Protection Group
Cannot Edit STS
Cannot Modify Protect Card
Cannot Perform ACO
Cannot Provision Equipment
Cannot Provision Protection Equipment
Cannot Set Bidirectional Protection Group
Cannot Set Protection Group
Cannot Set Protection Group Name
Cannot Set Protection Group Revertive Behavior

SROF (continued)

Cannot Set Revertive Time In Non-revertive Mode
Cannot Set Span Revertive Mode Unless 4-Fiber Ring
Cannot Set Span Revertive Time In Non-revertive Mode
Cannot Set Span Revertive Time Unless 4-Fiber Ring
Cannot Switch For Specified Connection Type
Cannot Switch For Specified Path
Cannot Update Synchronization Reference List
Command Not Supported
Cross-Connection Creation Failed
DCC Not In Use
Date Or Time Required
Element Not Found
Equipment Does Not Match Request
Equipment Type Not Supported
Facility Not Provisioned
Generation1 Does Not Support Given Quality Of RES
Get IOR Failed
Host Not In IP Address Format
Incompatible Cross-Connection Width
Insufficient Bandwidth
Insufficient Path Width For Cross-connection
Insufficient Path Width For Test Access
Internal Exercise Failure
Internal Facility Type Failure
Invalid Control Type (CONTTYPE) For AID
Invalid Cross-Connection Path
Invalid FTP Username/Password
Invalid Loopback Provision
Invalid Operation For Connection Type
Invalid Operation For Specified Path
Invalid Path
Invalid Protection Group
Invalid Protection Switch Operation
Invalid State When Loopback Present
Invalid Synchronization Source
Invalid UPSR Path
Loopback Type Does Not Match
MIC Cards Cannot Be Reset
Maximum User Limit Reached
Node::General Not Available
Operate Alarm Cutoff Failed
Operation Not Supported
OspfTopology::OSPFTopo Not Available
Package File Not Found
Path Already In Use
Path Specified Is Not Valid
Pool Does Not Exist
Protect Card Busy
Requested Operation Failed
Ring Reversion Failed

SROF (continued)

STS Does Not Exist
STS Does Not Have TAP
STS Is Already In Use
STS Path Width Does Not Match
STS Rates Do Not Match
Security::General Not Available
Software Activation Failed
Software Reversion Failed
Span Reversion Failed
Specified Operation Is Not Valid
Test Access Active
UPSR Must Exist In Order To Change Revertive Behavior
Unsupported Command Type
Unsupported Element Type
VT Does Not Exist
VT Does Not Have TAP
VT Not Found
XC Card Does Not Support VT Cross-Connection

SRQN

BLSR Creation Failed
BLSR Deletion Failed
BLSR Does Not Exist
BLSR Not Found
Cannot Edit SENDDUS On Protect Port
Cannot Edit SYNCMSG On Protect Port
DCC Not Allowed On Protect Port
Data Access Request Failed
Invalid Mode For Current Configuration
Invalid Request
Protect Card Does Not Support Electrical Protection
Protect Card Does Not Support Protection Type
Sync Status Messaging (SSM) Not Allowed With SDH Mode

SSRD

Manual Switch Cannot Override Forced Switch
Switch Request Denied

SSRE

Memory Resources Exceeded

SWFA

Working Unit Failed Or Missing

SWLD

Working Unit Locked


7.2.2 Errors Listed by Command

Table 7-22 Errors listed by Command 

Command
Error Code
Error Message

ACT-USER

SDBE

Cannot Access Node ID
Internal Database Error

 

SROF

Get IOR Failed

ALW-MSG-ALL

SAAL

Already Allowed

 

SAIN

Already Inhibited

ALW-MSG-DBCHG

SAAL

Already Allowed

 

SAIN

Already Inhibited

ALW-PMREPT-ALL

SAAL

Already Allowed

 

SAIN

Already Inhibited

ALW-SWDX-EQPT

ENEQ

Equipment Not Found

 

IIAC

Invalid AID

 

IICM

Input, Invalid Command

 

SDBE

Internal Access Failed
Internal Database Error

 

SROF

Get IOR Failed

 

SRQN

Invalid Request

ALW-SWTOPROTN-EQPT

ENEQ

Equipment Not Found

 

IDNV

Input, Data Not Valid
Invalid Protid

 

IIAC

Input, Invalid Access
Invalid AID

 

SAAL

Already Allowed

 

SDBE

Cannot Access Protection Group
Internal Access Failed|
Internal Database Error

 

SNVS

Protection Group Does Not Exist
Working Unit Already Active
Working Unit Already Standby

 

SROF

Cannot Access Protection Group Information
Cannot Access Protection Group Name

 

SRQN

Invalid Request

ALW-SWTOWKG-EQPT

ENEQ

Equipment Not Found

 

IDNV

Input, Data Not Valid
Invalid Protid

 

IIAC

Input, Invalid Access
Invalid AID

 

IICM

Input, Invalid Command

 

SAAL

Already Allowed

 

SDBE

Cannot Access Protection Group
Internal Access Failed
Internal Database Error

 

SNVS

Protection Group Does Not Exist
Working Unit Already Active
Working Unit Already Standby

 

SROF

Cannot Access Protection Group Information
Cannot Access Protection Group Name
Get IOR Failed

 

SRQN

Invalid Request

APPLY

IIDT

Cannot Activate To Older Software
Cannot Revert From R2 To R1
Cannot Revert To Newer Software
Command Already In Progress
Flash Manager Not Active
Invalid Software Switch Type
Software Activate/Revert Failed
Software Not Available For Switch

 

SDBE

Internal Database Error

 

SROF

Get IOR Failed
Software Activation Failed
Software Reversion Failed

CANC-USER

SDBE

Internal Database Error

 

SROF

Get IOR Failed

CHG-ACCMD-<STS_PATH>

IDNV

Invalid TAP Number

 

IIAC

Equipment Does Not Match Request
Multiple TAP AIDs Not Supported

 

IICM

Input, Invalid Command

 

RTEN

Invalid TAP AID

 

SDBE

Internal Database Error

 

SRCN

Already In Requested Mode

 

SROF

Unknown Internal Error
STS Rates Do Not Match

CHG-ACCMD-DS1

ICNV

Equipment Does Not Match Request

 

IIAC

Invalid AID
Multiple TAP AIDs Not Supported

 

IICM

Input, Invalid Command

 

SDBE

Internal Database Error

 

SRCN

Already In Requested Mode

 

SROF

Tap Number Does Not Exist

CHG-ACCMD-T1

ICNV

Equipment Does Not Match Request

 

IIAC

Invalid AID
Multiple TAP AIDs Not Supported

 

IICM

Input, Invalid Command

 

SDBE

Internal Database Error

 

SRCN

Already In Requested Mode

 

SROF

Tap Number Does Not Exist

CHG-ACCMD-T3

IDNV

Invalid TAP Number

 

IIAC

Equipment Does Not Match Request
Multiple TAP AIDs Not Supported

 

IICM

Input, Invalid Command

 

RTEN

Invalid TAP AID

 

SDBE

Internal Database Error

 

SRCN

Already In Requested Mode

 

SROF

Unknown Internal Error
STS Rates Do Not Match

CHG-ACCMD-VT1

ICNV

Equipment Does Not Match Request

 

IIAC

Invalid AID
Multiple TAP AIDs Not Supported

 

IICM

Input, Invalid Command

 

SDBE

Internal Database Error

 

SRCN

Already In Requested Mode

 

SROF

Tap Number Does Not Exist

CONN-TACC-<STS_PATH>

ENEQ

Equipment Not Found

 

IDNV

Invalid TAP Number
Multiple AIDs Not Allowed

 

IIAC

Invalid AID
Cannot Make Changes To Protect Card
Invalid TAP
Multiple AIDs Not Supported

 

IICM

Input, Invalid Command

 

RRNG

Invalid Slot Number

 

SDBE

Cannot Access STS
Internal Access Failed
Internal Database Error
STS Not Provisioned

 

SROF

STS Rates Do Not Match
Get IOR Failed

CONN-TACC-DS1

ENEQ

Equipment Not Found

 

ICNV

Invalid Command

 

IDNV

Invalid TAP Number

 

IIAC

Cannot Make Changes To Protect Card
Equipment Does Not Match Request
Invalid AID
Invalid DS1 AID
Multiple TAP AIDs Not Supported

 

IICM

Input, Invalid Command

 

IPNV

Invalid Parameter

 

SDBE

Internal Access Failed
Internal Database Error

 

SROF

Tap Number Does Not Exist
Unknown Internal Error
Cannot Access Cross-Connection
Get IOR Failed
STS Rates Do Not Match

CONN-TACC-T1

ENEQ

Equipment Not Found

 

ICNV

Invalid Command

 

IDNV

Invalid TAP Number

 

IIAC

Cannot Make Changes To Protect Card
Equipment Does Not Match Request
Invalid AID
Invalid DS1 AID
Multiple TAP AIDs Not Supported

 

IICM

Input, Invalid Command

 

IPNV

Invalid Parameter

 

SDBE

Internal Access Failed
Internal Database Error

 

SROF

Tap Number Does Not Exist
Unknown Internal Error
Cannot Access Cross-Connection
Get IOR Failed
STS Rates Do Not Match

CONN-TACC-T3

ENEQ

Equipment Not Found

 

ICNV

Invalid Command

 

IDNV

Invalid TAP Number

 

IIAC

Cannot Make Changes To Protect Card
Equipment Does Not Match Request
Invalid AID
Invalid DS1 AID
Multiple TAP AIDs Not Supported

 

IICM

Input, Invalid Command

 

IPNV

Invalid Parameter

 

SDBE

Internal Access Failed
Internal Database Error

 

SROF

Tap Number Does Not Exist
Unknown Internal Error
Cannot Access Cross-Connection
Get IOR Failed
STS Rates Do Not Match

CONN-TACC-VT1

ENEQ

Equipment Not Found

 

ICNV

Invalid Command

 

IIAC

Cannot Make Changes To Protect Card
Equipment Does Not Match Request
Invalid AID
Multiple AIDs Not Supported

 

IICM

Input, Invalid Command

 

RRNG

Invalid Slot Number

 

RTEN

Invalid TAP Number

 

SDBE

Internal Access Failed
Internal Database Error

 

SROF

Cannot Access Cross-Connection
Get IOR Failed
Invalid Path
Path Already In Use

COPY-RFILE

IIAC

Invalid AID

 

IIDT

Hostname Missing In FTP URL
Mandatory FTP URL Not Provided
Null Outputs In FTP URL Parsing
Only SWDL Is Supported For The xfertype Argument
Package Name Missing in FTP URL
Password Missing In FTP URL
Unknown Error Processing FTP URL.
Username Missing In FTP URL
ftp:// Missing In FTP URL

 

IPEX

Invalid Payload Block. Extra Parameters

 

IPMS

Invalid Payload Block. Missing Mandatory Field

 

SDBE

Internal Database Error

 

SROF

Active Flash Not Ready
Database Busy
Flash Busy
Generic download failure message
Software Error
Standby Flash Not Ready
Get IOR Failed

DISC-TACC

IDNV

Invalid TAP Number

 

IIAC

Multiple TAP AIDs Not Supported

 

RTEN

Invalid TAP AID
TAP Not Found

 

SDBE

Internal Database Error

 

SROF

Tap Number Does Not Exist
Unknown Internal Error

DLT-BLSR

IDNV

Invalid Data For 2F-BLSR

 

IIAC

Input, Invalid Node ID
Input, Invalid Ring ID

 

SROF

Set NodeId Failed
Set RingId Failed
Cannot Access Facility
Cannot Set Span Revertive Mode Unless
4-Fiber Ring
Cannot Set Span Revertive Time Unless 4-Fiber Ring
Facility Not Provisioned
Ring Reversion Failed
Span Reversion Failed

 

SRQN

BLSR Deletion Failed
BLSR Does Not Exist
Data Access Request Failed

DLT-CRS-<STS_PATH>

ENEQ

Equipment Not Found

 

IIAC

Invalid AID
Cannot Make Changes To Protect Card

 

IICM

Input, Invalid Command

 

RRNG

Invalid Slot Number

 

SDBE

Internal Access Failed
Internal Database Error

 

SROF

Cannot Access Cross-Connection
Cannot Delete Cross-Connection
Get IOR Failed
STS Rates Do Not Match

 

SSRE

Memory Resources Exceeded

DLT-CRS-VT1

ENEQ

Equipment Not Found

 

IIAC

Invalid AID
Cannot Make Changes To Protect Card

 

IICM

Input, Invalid Command

 

RRNG

Invalid Slot Number

 

SDBE

Internal Database Error
Internal Access Failed

 

SROF

Cannot Access Cross-Connection
Cannot Delete Cross-Connection
Get IOR Failed

 

SSRE

Memory Resources Exceeded

DLT-EQPT

ENEQ

Equipment Not Found

 

IIAC

Invalid AID

 

IIDT

Invalid Data Parameter

 

SDBE

Internal Access Failed
Internal Database Error

 

SPLD

Cannot Delete Equipment
Equipment In Use

 

SROF

Get IOR Failed

 

SRQN

Invalid Request

DLT-FFP-<OCN_TYPE>

ENEQ

Equipment Not Found

 

IDNC

Invalid Data

 

IIAC

ALL, Ranging and Grouping Are Not Supported
Invalid AID
Invalid Protect AID Or Working AID
Equipment Does Not Match Request

 

IICM

Input, Invalid Command

 

SDBE

Cannot Access Protection Group
Delete Protection Group Failed
Internal Access Failed
Internal Database Error

 

SROF

1+1 Protection Group Not Found
Cannot Access Facility
Cannot Access Protection Group Name
Facility Not Provisioned
Get IOR Failed

DLT-UCP-CC

IICM

Input, Invalid Command

 

SDBE

Internal Database Error

 

SROF

Get IOR Failed

DLT-UCP-IF

IICM

Input, Invalid Command

 

SDBE

Internal Database Error

 

SROF

Get IOR Failed

DLT-UCP-NBR

IICM

Input, Invalid Command

 

SDBE

Internal Database Error

 

SROF

Get IOR Failed

DLT-USER-SECU

PICC

Unknown CORBA Exception (Internal Error)
Unknown User
User Not Authorized

 

PIUC

Cannot Delete The Logged In User
User Currently Logged Into Another Session

 

SDBE

Internal Database Error

 

SROF

Get IOR Failed

ED-<OCN_TYPE>

ENEQ

Equipment Not Found

 

IDNC

Invalid Data

 

IDRG

Invalid PJMON Value

 

IIAC

Equipment Does Not Match Request
Invalid AID

 

IICM

Input, Invalid Command

 

SDBE

Cannot Access Equipment
Cannot Access Facility
Cannot Set Pointer Justification Monitoring
Parameter (PJMON)
Cannot Switch To E2 Byte With Express
Orderwire IS
Facility Does Not Exist
Facility Does Not Match Request
Facility Is Not Provisioned
Internal Access Failed
Internal Database Error
Not Supported On EC1 Interface
Synchronization Status Messaging (SSM)

 

SROF

All DCCs In Use
Cannot Access DCC
Cannot Access Facility
Cannot Access Performance Monitoring Statistics
Facility Not Provisioned
Get IOR Failed

 

SRQN

Invalid Mode For Current Configuration

ED-<STS_PATH>

ENEQ

Equipment Not Found

 

IDNV

Cannot Make Changes To Protect Card
Invalid TAP Number
Multiple AIDs Not Allowed

 

IIAC

Expected Trace Not Supported On This Card Type
Expected Trace String Exceeds Maximum Length (62)
Incorrect Card Type
Invalid AID
Trace Mode Not Supported On This Card Type
Trace Not Supported On This Card Type
Trace String Exceeds Maximum Length (62)

 

IICM

Input, Invalid Command

 

IIDT

Only NORM CMD_MODE Is Supported

 

IPNC

Parameters Not Compatible

 

IPNV

Cannot Set Expected Path Trace In Auto Mode

 

RRNG

Invalid Slot Number

 

SDBE

Cannot Access STS
Incompatible Parameter Values
Internal Database Error
STS Not Provisioned

 

SROF

Cannot Access Cross-connect
Cannot Access Cross-Connection
Cannot Access VT
Cross-connection Does Not Exist
Get IOR Failed
STS Rates Do Not Match

 

IPNV

Cannot Set Expected Path Trace In Auto Mode

 

SDBE

Internal Database Error
Synchronization Status Messaging (SSM)
Used Frame Format Does Not Support

ED-BITS

SROF

Get IOR Failed

 

IPNV

Invalid Parameter

 

SDBE

Internal Database Error
Synchronization Status Messaging (SSM)
Used Frame Format Does Not Support

 

IIAC

Invalid AID

ED-BLSR

IDNV

Invalid Data For 2F-BLSR

 

SROF

4-Fiber Ring
Cannot Access Facility
Cannot Set Span Revertive Mode Unless
Cannot Set Span Revertive Time Unless
Facility Not Provisioned
Set NodeId Failed
Set RingId Failed
Ring Reversion Failed
Span Reversion Failed

 

SRQN

BLSR Deletion Failed
BLSR Does Not Exist
Data Access Request Failed

 

IIAC

Input, Invalid Node ID
Input, Invalid Ring ID

ED-CRS-<STS_PATH>

ENEQ

Equipment Not Found

 

IIAC

Cannot make changes to protect card
Invalid AID

 

IICM

Input, Invalid Command

 

RRNG

Invalid Slot Number

 

SDBE

Internal Access Failed
Internal Database Error

 

SNCC

Cross-connection does not exist

 

SROF

Get IOR Failed

 

SSRE

Memory resource denial

ED-CRS-VT1

ENEQ

Equipment Not Found

 

IIAC

Cannot make changes to protect card
Invalid AID

 

RRNG

Invalid Slot Number

 

SDBE

Internal Access Failed
Internal Database Error

 

SNCC

Cross-connection does not exist

 

SROF

Get IOR Failed

 

SSRE

Memory resource denial

ED-DAT

IIAC

Invalid Year

 

SDBE

Cannot Access Date/Time
Cannot Set Date
Cannot Set Date When Using SNTP

 

SROF

Get IOR Failed

ED-DS1

ENEQ

Equipment Not Found
Equipment Not Provisioned

 

ICNV

Invalid Command

 

IDNV

Incompatible Equipment Type
Invalid TAP Number

 

IIAC

Cannot Make Changes To Protect Card
Equipment Does Not Match Request
Invalid AID
Invalid DS1 AID

 

IICM

Input, Invalid Command

 

IPNV

Invalid Parameter

 

SDBE

Operation not supported by this card
Cannot Access Object
Internal Access Failed
Internal Database Error

 

SROF

Get IOR Failed

ED-EC1

ENEQ

Equipment Not Found

 

IDNC

Invalid Data

 

IIAC

Cannot Make Changes To Protect Card
Equipment Does Not Match Request
Invalid AID

 

IICM

Input, Invalid Command

 

SDBE

Internal Access Failed
Internal Database Error

 

SROF

Get IOR Failed

ED-EQPT

ENEQ

Equipment Not Found

 

ICNV

Equipment In Use

 

IDNV

Cannot Change Protection Type
Command Not Valid On Protect Card
Incompatible Equipment Type For Protection
Incompatible Protect Slot For Protection
Multiple Protection Group Card Slot Identifiers Not Allowed
Protect Card Does Not Support Protection Type
Protect Slot Not Provisioned
Protection Group Does Not Exist

 

IIAC

ALL, Ranging and Grouping Are Not Supported
Invalid AID
Invalid Protect AID

 

IIDT

Invalid Revertive Time

 

IPMS

Invalid Payload Block. Missing Mandatory Field

ED-EQPT (continued)

IPNC

Cannot Change Existing Protection Type
Invalid Parameter
Parameters Are Not Consistent

 

IPNV

Invalid Reversion Mode For Protection Type
Invalid Parameter

 

SDBE

Cannot Access Protection Group
Cannot Access Protection State
Internal Access Failed
Internal Database Error

 

SNVS

Protection Group Does Not Exist

 

SRCN

Requested Condition Already Exists

 

SROF

Cannot Access Protection Group Information
Cannot Access Protection Group Name
Cannot Access Protection Group Reversion Information
Cannot Change XTC Protection Group
Cannot Create Protection Group
Cannot Delete Protection Group
Cannot Provision Protection Equipment
Cannot Set Protection Group Name
Get IOR Failed
Protect Card Busy
Unsupported Command Type

 

SRQN

Invalid Request
Protect Card Does Not Support Electrical Protection

ED-FFP-<OCN_TYPE>

ENEQ

Equipment Not Found

 

IDNC

Invalid Data

 

IIAC

Equipment Does Not Match Request
Invalid AID

 

IICM

Input, Invalid Command

 

IIDT

Invalid Data Parameter

 

SDBE

Cannot Access Protection Group
Internal Access Failed
Internal Database Error

 

SROF

1+1 Protection Group Not Found
Cannot Access Facility
Cannot Access Protection Group Name
Cannot Set Bidirectional Protection Group
Cannot Set Protection Group Name
Cannot Set Protection Group Revertive Behavior
Facility Not Provisioned
Get IOR Failed

ED-G1000

ENEQ

Equipment Not Found

 

ICNV

Invalid Command

 

IDNV

Invalid Ethernet Frame Size

 

IIAC

Invalid AID
Invalid G1000 Facility Port

 

IPEX

Invalid Payload Block. Extra Parameters

 

IPNC

Invalid Flow Control Value
Invalid Maximum Frame Size

 

SDBE

Internal Access Failed
Internal Database Error
Object Not Provisioned

 

SNVS

Cannot Operate Loopback In Current State

 

SROF

Get IOR Failed

ED-NE-GEN

IPNV

Invalid Default Router Address
Invalid IIOP Port number
Invalid IP Address
Invalid IP Configuration Parameter
Invalid IP Mask
Invalid LAN IP Address
Invalid LAN IP Mask
Invalid SNTP Host Address
Node Name Too Long
Set LAN IP Config Failed - Different From Node IP DHCP/OSPF on LAN Is Not Allowed

 

SDBE

Set LAN IP Configuration Failed
Set LAN IP Config Failed - OSPF Is Provisioned
Cannot Access IP Configuration
Cannot Access Node ID
Cannot Set IP Configuration
Cannot Set Node Name
Cannot Set SNTP Host Configuration
Internal Database Error

 

SDNA

Standby TCC Not Ready

 

SROF

Cannot Access LAN IP Configuration
Invalid MASK LAN IP Address
Set LAN IP Config Failed - Subnets Different
Get IOR Failed

ED-NE-SYNCN

SDBE

Cannot Access Synchronization Configuration
Internal Database Error

 

SROF

Generation1 Does Not Support Given Quality Of RES Get IOR Failed

ED-PID

PICC

Invalid User Password - Must Conform To TL1 Rules
New Password Same As Old Password
Unknown CORBA Exception (Internal Error)
Unknown User

 

PIUC

User Not Allowed To Change User Password

 

SDBE

Internal Database Error

 

SROF

Get IOR Failed

ED-SYNCN

IDNV

Invalid Reference
Multiple References Not Allowed

 

SNNS

Reference Not From Optical Card

 

SROF

Get IOR Failed

 

IPNV

Invalid Clock Source
Primary Reference Incompatible With Timing Mode
Reference Type Not Supported
Secondary Reference Incompatible With Timing Mode
Synchronization Source Already Defined For The Slot
Third Reference Incompatible With Timing Mode
Timing Mode Not Compatible

 

IDNC

Primary Source Cannot Be INTERNAL When Secondary Source Is Not INTERNAL
Primary Source Cannot Be INTERNAL When Third Source Is Not INTERNAL
Secondary Source Cannot Be INTERNAL When Third Source Is Not INTERNAL

 

SDBE

Internal Database Error

 

IIAC

Invalid AID
Invalid Reference

ED-T1

ENEQ

Equipment Not Found
Equipment Not Provisioned

 

ICNV

Invalid Command

 

IDNV

Incompatible Equipment Type
Invalid TAP Number

 

IIAC

Cannot Make Changes To Protect Card
Equipment Does Not Match Request
Invalid AID
Invalid DS1 AID

 

IICM

Input, Invalid Command

 

IPNV

Invalid Parameter

 

SDBE

Operation not supported by this card
Cannot Access Object
Internal Access Failed
Internal Database Error

 

SROF

Get IOR Failed

ED-T3

ENEQ

Equipment Not Found
Equipment Not Provisioned

 

ICNV

Invalid Command

 

IDNV

Frame Format Contains Invalid Data
Frame Format Not Supported On Equipment
Incompatible Equipment Type
Invalid TAP Number
Line Code Not Supported

 

IIAC

Cannot Make Changes To Protect Card
Equipment Does Not Match Request
Invalid AID
Invalid DS1 AID

 

IICM

Input, Invalid Command

 

IPNV

Invalid Parameter

 

SDBE

Operation not supported by this card
Cannot Access Object
Internal Access Failed
Internal Database Error

 

SROF

Get IOR Failed

ED-UCP-CC

IIAC

Routed CC Is Not Allowed to Provision MTU & CRCMD

 

IICM

Input, Invalid Command

 

SDBE

Internal Database Error

 

SROF

Get IOR Failed

ED-UCP-IF

IICM

Input, Invalid Command

 

SDBE

Internal Database Error

 

SROF

Get IOR Failed

ED-UCP-NBR

IIAC

HELLOINT Is Not Allowed If HELLOEN Is Disabled

 

IICM

Input, Invalid Command

 

SDBE

Internal Database Error

 

SROF

Get IOR Failed

ED-UCP-NODE

IICM

Input, Invalid Command

 

IPNV

Invalid Node Id

 

SDBE

Internal Database Error

 

SROF

Get IOR Failed

ED-USER-SECU

PICC

AID Required
Invalid User Access Privilege Value
Invalid User Identifier - Must Conform To TL1 Rules
Invalid User Password - Must Conform To TL1 Rules
New Password Same As Old Password
Unknown CORBA Exception (Internal Error)
Unknown User
User Access Privilege Required
User Already Exists
User Not Authorized
User Password Required

 

PIUC

User Currently Logged Into Another Session.
User Is Not Superuser
User Not Allowed To Change User Access Privilege
User Not Allowed To Change User Password

 

SDBE

Internal Database Error

 

SROF

Get IOR Failed
Maximum User Limit Reached

ED-VT1

ENEQ

Equipment Not Found

 

ICNV

Invalid Command

 

IDNV

Invalid TAP Number

 

IIAC

Cannot Make Changes To Protect Card
Equipment Does Not Match Request
Invalid AID

 

IICM

Input, Invalid Command

 

IIDT

Only NORM CMD_MODE Is Supported

 

IPNC

Parameters Not Compatible

ED-VT1 (continued)

IPNV

Cross-Connection Does Not Have UPSR Path Selector

 

RRNG

Invalid Slot Number

 

SDBE

Cannot Access STS
Cannot Access VT
Internal Access Failed
Internal Database Error
STS Not Provisioned
VT Not Provisioned

 

SROF

Cannot Access Cross-Connection
Get IOR Failed

ENT-BLSR

IIAC

Input, Invalid Duplicated Port ID
Input, Invalid Node ID
Input, Invalid Ring ID
Input, Invalid Work/Prot Port
Input Invalid MODE for BLSR Creation
MODE Is Required for BLSR Creation
SRVRTV/SRVTM/EASTPROT/WESTPROT Are Not Allowed for 2F-BLSR Creation
RingId Does Not Match with AID Number

 

SRQN

BLSR Creation Failed

ENT-CRS-<STS_PATH>

ENEQ

Equipment Not Found

 

IIAC

Cannot Make Changes To Protect Card
Invalid AID
Only CCT=2WAY Is Allowed When G1000 Port Is Used
UPSR Cross-Connections Are Not Allowed When A G1000 Port Is Used

 

IICM

Input, Invalid Command

 

RRNG

Invalid Slot Number

 

SDBE

Internal Access Failed
Internal Database Error

 

SNCN

Cross-Connection Type Not Supported In TL1

 

SROF

Cannot Create Cross-Connection Between Incompatible Interfaces
Cross-Connection Creation Failed
Get IOR Failed
Insufficient Path Width For Cross-connection
Invalid Cross-Connection Path
Invalid UPSR Path
Path Already In Use

 

SSRE

Memory Resources Exceeded

ENT-CRS-VT1

SROF

Cross-Connection Creation Failed
Get IOR Failed
Invalid Cross-Connection Path
Invalid UPSR Path
Path Already In Use

 

SSRE

Memory Resources Exceeded

 

SDBE

Internal Access Failed
Internal Database Error

 

IIAC

Cannot Make Changes To Protect Card
Invalid AID

ENT-EQPT

ENEQ

Equipment Not Found

 

ICNV

Equipment In Use

 

IDNV

At least an XC10G XC card is needed for this equipment type
Command Not Valid On Protect Card
Incompatible Equipment Type For Protection
Incompatible Protect Slot For Protection
Invalid Equipment Type
Multiple Protection Group Card Slot Identifiers Not Allowed
Protect Card Does Not Support Protection Type Protect Slot Not Provisioned
Protection Group Card Slot Identifier Field Required

 

IIAC

ALL, Ranging and Grouping Are Not Supported
Invalid AID
Invalid Protect AID

 

IIDT

Invalid Data Parameter
Invalid Revertive Time

 

IPMS

Invalid Payload Block. Missing Mandatory Field

 

IPNC

Cannot Change Existing Protection Type
Invalid Parameter

 

IPNV

Invalid Reversion Mode For Protection Type
Invalid Parameter

 

SAAS

Equipment Already Provisioned

 

SDBE

Cannot Access Protection Group
Cannot Access Protection State
Internal Access Failed
Internal Database Error

 

SNVS

Protection Group Does Not Exist

 

SPLD

Cannot Delete Equipment
Equipment In Use

 

SRCN

Requested Condition Already Exists

ENT-EQPT (continued)

SROF

Cannot Access Protection Group Information
Cannot Access Protection Group Name
Cannot Access Protection Group Reversion Information
Cannot Create Protection Group
Cannot Delete Protection Group
Cannot Provision Equipment
Cannot Provision Protection Equipment
Cannot Set Protection Group Name
Get IOR Failed
Protect Card Busy
Unsupported Command Type

 

SRQN

Invalid Request
Protect Card Does Not Support Electrical Protection

ENT-FFP-<OCN_TYPE>

ENEQ

Equipment Not Found

 

IDMS

Missing Internal Data

 

IDNC

Invalid Data

 

IIAC

ALL, Ranging and Grouping Are Not Supported
Equipment Does Not Match Request
Invalid AID

 

IICM

Input, Invalid Command

 

IIDT

Memory Out Of Range

 

SDBE

Cannot Create 1+1 Protection Group
Internal Access Failed
Internal Database Error

 

SPLD

Cannot Create 1+1 Protection Group
Facility Is Busy

 

SROF

Get IOR Failed

ENT-UCP-CC

IIAC

PORT Data Is Needed To Create SDCC Type IPCC
Routed CC Is Not Allowed to Provision MTU & CRCMD

 

IICM

Input, Invalid Command

 

SDBE

Internal Database Error

 

SROF

Get IOR Failed

ENT-UCP-IF

IICM

Input, Invalid Command

 

SDBE

Internal Database Error

 

SROF

Get IOR Failed

ENT-UCP-NBR

IIAC

HELLOINT Is Not Allowed If HELLOEN Is Disabled
Invalid Neighbor Node ID
NBRIX Does Not Match with AID
NODEID Is Not Allowed If NDEN Is Enabled
Neighbor Name Can Not be Empty
Node Name Too Long

 

IICM

Input, Invalid Command

 

SDBE

Internal Database Error

 

SROF

Get IOR Failed

ENT-USER-SECU

PICC

Invalid User Access Privilege Value
Invalid User Identifier - Must Conform To TL1 Rules
Invalid User Password - Must Conform To TL1 Rules
Unknown CORBA Exception (Internal Error)
Unknown User
User Already Exists
User Not Authorized

 

PIUC

User Is Not Superuser

 

SDBE

Internal Database Error

 

SROF

Get IOR Failed
Maximum User Limit Reached

EX-SW-<OCN_BLSR>

IIAC

Equipment Does Not Match Request
Invalid AID

 

IICM

Input, Invalid Command

 

IPNV

Exercise Is Not Allowed On Protected Facility
Invalid Switch Type

 

SDBE

Internal Access Failed
Internal Database Error

 

SNVS

BLSR East Operation Already Set
BLSR West Operation Already Set
Facility Not Part Of BLSR
Invalid BLSR Element

 

SROF

Cannot Access Facility
Facility Not Provisioned
Internal Exercise Failure
Invalid Protection Switch Operation

INH-MSG-ALL

SAAL

Already Allowed

 

SAIN

Already Inhibited

ING-MSG_DBCHG

SAAL

Already Allowed

 

SAIN

Already Inhibited

INH-PMREPT-ALL

SAAL

Already Allowed

 

SAIN

Already Inhibited

INH-SWDX-EQPT

ENEQ

Equipment Not Found

 

IIAC

Invalid AID

 

IICM

Input, Invalid Command

 

SDBE

Internal Access Failed
Internal Database Error

 

SROF

Get IOR Failed

 

SRQN

Invalid Request

INH-SWTOPROTN-EQPT

ENEQ

Equipment Not Found

 

IDNV

Input, Data Not Valid
Invalid Protid

 

IIAC

Input, Invalid Access
Invalid AID

 

IICM

Input, Invalid Command

 

SAAL

Already Allowed

 

SDBE

Cannot Access Protection Group
Internal Access Failed
Internal Database Error

 

SNVS

Protection Group Does Not Exist
Working Unit Already Active
Working Unit Already Standby

 

SROF

Cannot Access Protection Group Information
Cannot Access Protection Group Name
Get IOR Failed

 

SRQN

Invalid Request

INH-SWTOWKG-EQPT

ENEQ

Equipment Not Found

 

IDNV

Input, Data Not Valid
Invalid Protid

 

IIAC

Input, Invalid Access
Invalid AID

 

IICM

Input, Invalid Command

 

SAAL

Already Allowed

 

SDBE

Cannot Access Protection Group
Internal Access Failed
Internal Database Error

 

SNVS

Protection Group Does Not Exist
Working Unit Already Active
Working Unit Already Standby

INH-SWTOWKG-EQPT (continued)

SROF

Cannot Access Protection Group Information
Cannot Access Protection Group Name
Get IOR Failed

 

SRQN

Invalid Request

INIT-REG-<OCN_TYPE>>

ENEQ

Equipment Not Found
Equipment Not Present

 

IDNC

Invalid Data

 

IIAC

Equipment Does Not Match Request
Invalid AID

 

IICM

Input, Invalid Command

 

SDBE

Cannot Access Equipment
Internal Access Failed
Internal Database Error

 

SNCN

This Direction Is Not Supported

 

SROF

Cannot Access Performance Monitoring Statistics
Get IOR Failed

INIT-REG-<STS_PATH>

ENEQ

Equipment Not Found
Equipment Not Present
Internal Communication Error

 

IIAC

Cannot Make Changes To Protect Card
Invalid AID

 

IICM

Input, Invalid Command

 

SDBE

Cannot Access Equipment
Internal Access Failed
Internal Database Error
STS Not Provisioned

 

SNCN

This Direction Is Not Supported

 

SROF

Get IOR Failed

INIT-REG-DS1

ENEQ

Equipment Not Found
Equipment Not Present
Equipment Not Provisioned
Internal Communication Error

 

ICNV

Invalid Command

 

IDNV

Incompatible Equipment Type

 

IIAC

Cannot Make Changes To Protect Card
Equipment Does Not Match Request
Invalid AID
Invalid DS1 AID

 

IICM

Input, Invalid Command

INIT-REG-DS1 (continued)

SDBE

Cannot Access Equipment
Cannot Access Object
Internal Access Failed
Internal Database Error

 

SNCN

This Direction Is Not Supported

 

SROF

Get IOR Failed

INIT-REG-EC1

ENEQ

Equipment Not Found
Equipment Not Present

 

IDNC

Invalid Data

 

IIAC

Equipment Does Not Match Request
Invalid AID

 

IICM

Input, Invalid Command

 

SDBE

Cannot Access Equipment
Internal Access Failed
Internal Database Error

 

SNCN

This Direction Is Not Supported

 

SROF

Cannot Access Performance Monitoring Statistics
Get IOR Failed

INIT-REG-T1

ENEQ

Equipment Not Found
Equipment Not Present
Equipment Not Provisioned
Internal Communication Error

 

ICNV

Invalid Command

 

IDNV

Incompatible Equipment Type

 

IIAC

Cannot Make Changes To Protect Card
Equipment Does Not Match Request
Invalid AID
Invalid DS1 AID

 

IICM

Input, Invalid Command

 

SDBE

Cannot Access Equipment
Cannot Access Object
Internal Access Failed
Internal Database Error

 

SNCN

This Direction Is Not Supported

 

SROF

Get IOR Failed

INIT-REG-T3

ENEQ

Equipment Not Found
Equipment Not Present
Equipment Not Provisioned
Internal Communication Error

 

ICNV

Invalid Command

 

IDNV

Incompatible Equipment Type

NIT-REG-T3 (continued)

IIAC

Cannot Make Changes To Protect Card
Equipment Does Not Match Request
Invalid AID
Invalid DS1 AID

 

IICM

Input, Invalid Command

 

SDBE

Cannot Access Equipment
Cannot Access Object
Internal Access Failed
Internal Database Error

 

SNCN

This Direction Is Not Supported

 

SROF

Get IOR Failed

INIT-REG-VT1

ICNV

Invalid Command
Operation not supported by this card

 

IIAC

Cannot Make Changes To Protect Card
Equipment Does Not Match Request
Invalid AID

 

IICM

Input, Invalid Command

 

SDBE

Cannot Access VT
Internal Database Error
VT Not Provisioned

 

SNCN

This Direction Is Not Supported

 

SROF

Get IOR Failed
Operation Not Supported

INIT-SYS

ENEQ

Equipment Not Found
Equipment Not Present

 

IIAC

ALL, Ranging and Grouping Are Not Supported
Invalid AID

 

SDBE

Cannot Access Equipment
Internal Access Failed
Internal Database Error

 

SROF

Get IOR Failed
MIC Cards Cannot Be Reset

 

SRQN

Invalid Request

OPR-ACO-ALL

SROF

Operate Alarm Cutoff Failed

OPR-EXT-CONT

ENEQ

Control Not Provisioned

 

SAOP

Control Already Operated
Control Not Operated Or Already Released

 

SDBE

Cannot Access Controls
Internal Database Error

 

SROF

Get IOR Failed
Invalid Control Type (CONTTYPE) For AID

 

SRQN

Invalid Request

OPR-LPBK-<OCN_TYPE>

ENEQ

Equipment Not Found

 

IDNC

Invalid Data

 

IIAC

Equipment Does Not Match Request
Invalid AID

 

IICM

Input, Invalid Command

 

SDBE

Cannot Access Facility
Cannot Access Interface
Internal Access Failed
Internal Database Error

 

SNVS

Cannot Operate Loopback In Current State

 

SROF

Get IOR Failed
Invalid Loopback Provision

OPR-LPBK-DS1

ENEQ

Equipment Not Found

 

ICNV

Invalid Command

 

IIAC

Cannot Make Changes To Protect Card
Equipment Does Not Match Request
Invalid AID
Invalid DS1 AID

 

IICM

Input, Invalid Command

 

SDBE

Cannot Access Interface
Cannot Access Object
Internal Database Error

 

SNVS

Cannot Operate Loopback In Current State
Loopback Already In Progress
Loopback Not In Progress

 

SROF

Get IOR Failed
Invalid Loopback Provision
Loopback Type Does Not Match

OPR-LPBK-EC1

ENEQ

Equipment Not Found

 

IDNC

Invalid Data

 

IIAC

Cannot Make Changes To Protect Card
Equipment Does Not Match Request
Invalid AID

 

IICM

Input, Invalid Command

 

SDBE

Cannot Access Interface
Internal Access Failed
Internal Database Error

 

SNVS

Cannot Operate Loopback In Current State
Loopback Already In Progress
Loopback Not In Progress

OPR-LPBK-EC1 (continued)

SROF

Get IOR Failed
Invalid Loopback Provision
Loopback Type Does Not Match
Requested Operation Failed

OPR-LPBK-G1000

ENEQ

Equipment Not Found

 

ICNV

Invalid Command

 

IDNV

Facility Loopback Not Supported
Invalid Ethernet Frame Size

 

IIAC

Invalid AID
Invalid G1000 Facility Port

 

SDBE

Internal Access Failed
Internal Database Error
Object Not Provisioned

 

SNVS

Cannot Operate Loopback In Current State
Loopback Already In Progress
Loopback Not In Progress

 

SROF

Get IOR Failed
Unsupported Command Type

OPR-LPBK-T1

ENEQ

Equipment Not Found

 

ICNV

Invalid Command

 

IIAC

Cannot Make Changes To Protect Card
Equipment Does Not Match Request
Invalid AID
Invalid DS1 AID

 

IICM

Input, Invalid Command

 

SDBE

Cannot Access Interface
Cannot Access Object
Internal Access Failed
Internal Database Error

 

SNVS

Cannot Operate Loopback In Current State
Loopback Already In Progress
Loopback Not In Progress

 

SROF

Get IOR Failed
Invalid Loopback Provision
Loopback Type Does Not Match

OPR-LPBK-T3

ENEQ

Equipment Not Found

 

ICNV

Invalid Command

 

IIAC

Cannot Make Changes To Protect Card
Equipment Does Not Match Request
Invalid AID
Invalid DS1 AID

 

IICM

Input, Invalid Command

OPR-LPBK-T3 (continued)

SDBE

Cannot Access Interface
Cannot Access Object
Internal Access Failed
Internal Database Error

 

SNVS

Cannot Operate Loopback In Current State
Loopback Already In Progress
Loopback Not In Progress

 

SROF

Get IOR Failed
Invalid Loopback Provision
Loopback Type Does Not Match

OPR-PROTNSW-<OCN_TYPE>

ENEQ

Equipment Not Found

 

IDNC

Invalid Data

 

IIAC

Equipment Does Not Match Request
Invalid AID

 

IICM

Input, Invalid Command

 

SAMS

Already In Clear Maintenance State
Already In Force Maintenance State
Already In Lockout Maintenance State
Already In Manual Maintenance State

 

SDBE

Cannot Access Facility
Facility Does Not Match Request
Facility Is Not Provisioned
Internal Access Failed
Internal Database Error

 

SROF

Cannot Access Facility
Facility Not Provisioned
Get IOR Failed

OPR-PROTNSW-<STS_PATH>

ENEQ

Equipment Not Found

 

IDNV

Multiple AIDs Not Allowed

 

IIAC

Invalid AID
AID Validation Failed
Invalid Operation On Drop AID

 

IICM

Input, Invalid Command

 

RRNG

Invalid Slot Number

 

SDBE

Cannot Access Facility
Internal Access Failed
Internal Database Error
STS Not Provisioned

OPR-PROTNSW-<STS_PATH> (continued)

SROF

Cannot Access Cross-Connection
Cannot Switch For Specified Connection Type
Cannot Switch For Specified Path
Get IOR Failed
Invalid Protection Switch Operation
Path Specified Is Not Valid
Requested Operation Failed
Specified Operation Is Not Valid

 

SSRD

Switch Request Denied

OPR-PROTNSW-VT1

ENEQ

Equipment Not Found

 

ICNV

Invalid Command

 

IIAC

Equipment Does Not Match Request
Invalid AID
Invalid Operation On Drop AID

 

IICM

Input, Invalid Command

 

RRNG

Invalid Slot Number

 

SDBE

Internal Access Failed
Internal Database Error

 

SROF

Cannot Access Cross-Connection
Get IOR Failed
Invalid Operation For Connection Type
Invalid Operation For Specified Path
Invalid Protection Switch Operation
Path Specified Is Not Valid
Requested Operation Failed
Specified Operation Is Not Valid

 

SSRD

Switch Request Denied

OPR-SYNCNSW

SNVS

Already Switched To Internal Reference Source
Cannot Manually Switch To Active Timing Source
Invalid Clock Source

 

SROF

Get IOR Failed

 

SNCN

Cannot Switch To Inferior Reference Source
Clock Source Failed
Invalid Clock Source

 

SSRD

Manual Switch Cannot Override Forced Switch

 

IPNV

INT Not Valid For BITS-OUT
Invalid Parameter
Invalid Switch Command For Synchronization
New Source Must Be Specified
Reference Type Not Supported

 

SDBE

Internal Database Error

 

IIAC

Invalid AID

RLS-EXT-CONT

ENEQ

Control Not Provisioned

 

IIAC

Invalid AID

 

SAOP

Control Already Operated
Control Not Operated Or Already Released

 

SDBE

Cannot Access Controls
Internal Database Error

 

SROF

Get IOR Failed
Invalid Control Type (CONTTYPE) For AID

 

SRQN

Invalid Request

RLS-LPBK-<OCN_TYPE>

ENEQ

Equipment Not Found

 

IIAC

Equipment Does Not Match Request
Invalid AID

 

IICM

Input, Invalid Command

 

SDBE

Cannot Access Facility
Cannot Access Interface
Internal Access Failed
Internal Database Error

 

SNVS

Cannot Operate Loopback In Current State

 

SROF

Get IOR Failed
Invalid Loopback Provision

RLS-LPBK-DS1

ENEQ

Equipment Not Found

 

ICNV

Invalid Command

 

IIAC

Cannot Make Changes To Protect Card
Equipment Does Not Match Request
Invalid AID
Invalid DS1 AID

 

IICM

Input, Invalid Command

 

SDBE

Cannot Access Interface
Cannot Access Object
Internal Access Failed
Internal Database Error

 

SNVS

Cannot Operate Loopback In Current State
Loopback Already In Progress
Loopback Not In Progress

 

SROF

Get IOR Failed
Invalid Loopback Provision
Loopback Type Does Not Match

RLS-LPBK-EC1

ENEQ

Equipment Not Found

 

IDNC

Invalid Data

 

IIAC

Cannot Make Changes To Protect Card
Equipment Does Not Match Request
Invalid AID

 

IICM

Input, Invalid Command

 

SDBE

Cannot Access Interface
Internal Access Failed
Internal Database Error

 

SNVS

Cannot Operate Loopback In Current State
Loopback Already In Progress
Loopback Not In Progress

 

SROF

Get IOR Failed
Invalid Loopback Provision
Loopback Type Does Not Match
Requested Operation Failed

RLS-LPBK-G1000

ENEQ

Equipment Not Found

 

ICNV

Invalid Command

 

IDNV

Facility Loopback Not Supported
Invalid Ethernet Frame Size

 

IIAC

Invalid AID
Invalid G1000 Facility Port

 

SDBE

Internal Access Failed
Internal Database Error
Object Not Provisioned

 

SNVS

Cannot Operate Loopback In Current State
Loopback Already In Progress
Loopback Not In Progress

 

SROF

Get IOR Failed
Unsupported Command Type

RLS-LPBK-T1

ENEQ

Equipment Not Found

 

ICNV

Invalid Command

 

IIAC

Cannot Make Changes To Protect Card
Equipment Does Not Match Request
Invalid AID
Invalid DS1 AID

 

IICM

Input, Invalid Command

 

SDBE

Cannot Access Interface
Cannot Access Object
Internal Access Failed
Internal Database Error

RLS-LPBK-T1 (continued)

SNVS

Cannot Operate Loopback In Current State
Loopback Already In Progress
Loopback Not In Progress

 

SROF

Get IOR Failed
Invalid Loopback Provision
Loopback Type Does Not Match

RLS-LPBK-T3

ENEQ

Equipment Not Found

 

ICNV

Invalid Command

 

IIAC

Cannot Make Changes To Protect Card
Equipment Does Not Match Request
Invalid AID
Invalid DS1 AID

 

IICM

Input, Invalid Command

 

SDBE

Cannot Access Interface
Cannot Access Object
Internal Access Failed
Internal Database Error

 

SNVS

Cannot Operate Loopback In Current State
Loopback Already In Progress
Loopback Not In Progress

 

SROF

Get IOR Failed
Invalid Loopback Provision
Loopback Type Does Not Match

RLS-PROTNSW-<OCN_TYPE>

ENEQ

Equipment Not Found

 

IDNC

Invalid Data

 

IIAC

Equipment Does Not Match Request
Invalid AID

 

IICM

Input, Invalid Command

 

SAMS

Already In Clear Maintenance State
Already In Force Maintenance State
Already In Lockout Maintenance State
Already In Manual Maintenance State

 

SDBE

Cannot Access Facility
Facility Does Not Match Request
Facility Is Not Provisioned
Internal Access Failed
Internal Database Error

 

SROF

Cannot Access Facility
Facility Not Provisioned
Get IOR Failed

RLS-PROTNSW-<STS_PATH>

ENEQ

Equipment Not Found

 

IDNV

Multiple AIDs Not Allowed

 

IIAC

Invalid AID
Invalid Aid
AID Validation Failed
Invalid AID
Invalid Operation On Drop AID

 

IICM

Input, Invalid Command

 

RRNG

Invalid Slot Number

 

SDBE

Cannot Access STS
Internal Access Failed
Internal Database Error
STS Not Provisioned

 

SROF

Cannot Access Cross-Connection
Cannot Switch For Specified Connection Type
Cannot Switch For Specified Path
Get IOR Failed
Invalid Protection Switch Operation
Path Specified Is Not Valid
Requested Operation Failed
Specified Operation Is Not Valid

 

SSRD

Switch Request Denied

RLS-PROTNSW-VT1

ENEQ

Equipment Not Found

 

ICNV

Invalid Command

 

IIAC

Equipment Does Not Match Request
Invalid AID
Invalid Operation On Drop AID

 

IICM

Input, Invalid Command

 

RRNG

Invalid Slot Number

 

SDBE

Internal Access Failed
Internal Database Error

 

SROF

Cannot Access Cross-Connection
Get IOR Failed
Invalid Operation For Connection Type
Invalid Operation For Specified Path
Invalid Protection Switch Operation
Path Specified Is Not Valid
Requested Operation Failed
Specified Operation Is Not Valid

 

SSRD

Switch Request Denied

RLS-SYNCNSW

IIAC

Invalid AID

 

SDBE

Internal Database Error

 

SROF

Get IOR Failed

 

SNVS

No Switch In Progress

RMV-<OCN_TYPE>

ENEQ

Equipment Not Found

 

IDNC

Invalid Data

 

IIAC

Equipment Does Not Match Request
Invalid AID

 

IICM

Input, Invalid Command

 

IIDT

Only NORM CMD_MODE Is Supported
Only OOS PST Is Supported

 

SDBE

Internal Access Failed
Internal Database Error

 

SROF

Get IOR Failed

RMV-DS1

ENEQ

Equipment Not Found

 

ICNV

Invalid Command

 

IIAC

Equipment Does Not Match Request
Invalid AID

 

IDNV

Incompatible Equipment Type
Invalid TAP Number

 

IIAC

Cannot Make Changes To Protect Card
Equipment Does Not Match Request
Invalid AID
Invalid DS1 AID

 

IICM

Input, Invalid Command

 

IPNV

Invalid Parameter

 

SDBE

Operation not supported by this card
Cannot Access Object
Internal Access Failed
Internal Database Error

 

SROF

Get IOR Failed

RMV-EC1

ENEQ

Equipment Not Found

 

IDNC

Invalid Data

 

IIAC

Equipment Does Not Match Request
Invalid AID

 

IIAC

Equipment Does Not Match Request
Invalid AID

 

IICM

Input, Invalid Command

 

IIDT

Only NORM CMD_MODE Is Supported
Only OOS PST Is Supported

RMV-EC1 (continued)

SDBE

Internal Access Failed
Internal Database Error

 

SROF

Get IOR Failed

RMV-G1000

ENEQ

Equipment Not Found

 

IIAC

Invalid AID
Invalid G1000 Facility Port

 

IIDT

Invalid State Value
Only NORM CMD_MODE Is Supported

 

SDBE

Internal Access Failed
Internal Database Error

 

SROF

Command Not Supported
Get IOR Failed

RMV-T1

ENEQ

Equipment Not Found

 

ICNV

Invalid Command

 

IIAC

Equipment Does Not Match Request
Invalid AID
Invalid DS1 AID

 

IICM

Input, Invalid Command

 

IIDT

Only NORM CMD_MODE Is Supported
Only OOS PST Is Supported

 

SDBE

Internal Access Failed
Internal Database Error

 

SROF

Get IOR Failed

RMV-T3

ENEQ

Equipment Not Found

 

ICNV

Invalid Command

 

IIAC

Equipment Does Not Match Request
Invalid AID
Invalid DS1 AID

 

IICM

Input, Invalid Command

 

IIDT

Only NORM CMD_MODE Is Supported
Only OOS PST Is Supported

 

SDBE

Internal Access Failed
Internal Database Error

 

SROF

Get IOR Failed

RST-<OCN_TYPE>

ENEQ

Equipment Not Found

 

IDNC

Invalid Data

 

IIAC

Equipment Does Not Match Request
Invalid AID

 

IICM

Input, Invalid Command

 

IIDT

Only NORM CMD_MODE Is Supported
Only OOS PST Is Supported

 

SDBE

Internal Access Failed
Internal Database Error

 

SROF

Get IOR Failed

RST-DS1

ENEQ

Equipment Not Found

 

ICNV

Invalid Command

 

IIAC

Equipment Does Not Match Request
Invalid AID

 

IDNV

Incompatible Equipment Type
Invalid TAP Number

 

IIAC

Cannot Make Changes To Protect Card
Equipment Does Not Match Request
Invalid AID
Invalid DS1 AID

 

IICM

Input, Invalid Command

 

IPNV

Invalid Parameter

 

SDBE

Operation not supported by this card
Cannot Access Object
Internal Access Failed
Internal Database Error

 

SROF

Get IOR Failed

RST-EC1

ENEQ

Equipment Not Found

 

IDNC

Invalid Data

 

IIAC

Equipment Does Not Match Request
Invalid AID

 

IICM

Input, Invalid Command

 

SDBE

Internal Access Failed
Internal Database Error

 

SROF

Get IOR Failed

RST-G1000

ENEQ

Equipment Not Found

 

IIAC

Invalid AID
Invalid G1000 Facility Port

 

IIDT

Invalid State Value
Only NORM CMD_MODE Is Supported

 

SDBE

Internal Access Failed
Internal Database Error

 

SROF

Command Not Supported
Get IOR Failed

RST-T1

ENEQ

Equipment Not Found

 

ICNV

Invalid Command

 

IIAC

Equipment Does Not Match Request
Invalid AID
Invalid DS1 AID

 

IICM

Input, Invalid Command

 

SDBE

Internal Access Failed
Internal Database Error

 

SROF

Get IOR Failed

RST-T3

ENEQ

Equipment Not Found

 

ICNV

Invalid Command

 

IIAC

Equipment Does Not Match Request
Invalid AID
Invalid DS1 AID

 

IICM

Input, Invalid Command

 

SDBE

Internal Access Failed
Internal Database Error

 

SROF

Get IOR Failed

RTRV-<OCN_TYPE>

ENEQ

Equipment Not Found

 

IDNC

Invalid Data

 

IIAC

Equipment Does Not Match Request
Invalid AID

 

IICM

Input, Invalid Command

 

SDBE

Cannot Access Equipment
Cannot Access Facility
Cannot Access IP Configuration
Facility Does Not Exist
Facility Does Not Match Request
Facility Is Not Provisioned
Internal Access Failed
Internal Database Error

RTRV-<OCN_TYPE> (continued)

SROF

Cannot Access Facility
Cannot Access Performance Monitoring Statistics
Facility Not Provisioned
Get IOR Failed

RTRV-<STS_PATH>

ENEQ

Equipment Not Found
Equipment Not Present

 

IDNV

Multiple AIDs Not Allowed

 

IIAC

AID Validation Failed
Invalid AID

 

IICM

Input, Invalid Command

 

RRNG

Invalid Slot Number

 

SDBE

Cannot Access STS
Cannot Access Equipment
Cannot Access STS
Internal Access Failed
Internal Database Error
STS Not Provisioned

 

SNVS

Invalid Admin State

 

SROF

Cannot Access Cross-connect
Cannot Access Cross-Connection
Get IOR Failed

RTRV-ALM-<OCN_TYPE>

ENEQ

Equipment Not Found

 

IDNC

Invalid Data

 

IIAC

Equipment Does Not Match Request
Invalid AID

 

IICM

Input, Invalid Command

 

SDBE

Internal Access Failed
Internal Database Error

 

SROF

Get IOR Failed

RTRV-ALM-<STS_PATH>

IIAC

Invalid AID

 

IICM

Input, Invalid Command

 

SDBE

Cannot Access Conditions
Cannot Access STS
Internal Database Error
STS Not Provisioned

 

SROF

Get IOR Failed

RTRV-ALM-ALL

ENEQ

Equipment Not Found

 

IIAC

Invalid AID

 

RRNG

Invalid Slot Number

 

SDBE

Cannot Access Object
Internal Access Failed
Internal Database Error

 

SROF

Get IOR Failed

RTRV-ALM-BITS

IIAC

Invalid AID

 

SDBE

Cannot Access Conditions

 

SROF

Get IOR Failed

RTRV-ALM-DS1

IIAC

Equipment Does Not Match Request
Invalid AID
Invalid DS1 AID

 

IICM

Input, Invalid Command

 

SDBE

Cannot Access Conditions
Internal Access Failed
Internal Database Error

 

SROF

Get IOR Failed

RTRV-ALM-E100

ENEQ

Equipment Not Found

 

IDNC

Invalid Data

 

IIAC

Equipment Does Not Match Request
Invalid AID

 

SDBE

Internal Access Failed
Internal Database Error

 

SROF

Get IOR Failed

RTRV-ALM-E1000

ENEQ

Equipment Not Found

 

IDNC

Invalid Data

 

IIAC

Equipment Does Not Match Request
Invalid AID

 

SDBE

Internal Access Failed
Internal Database Error

 

SROF

Get IOR Failed

RTRV-ALM-EC1

ENEQ

Equipment Not Found

 

IDNC

Invalid Data

 

IIAC

Equipment Does Not Match Request
Invalid AID

 

IICM

Input, Invalid Command

 

SDBE

Cannot Access Conditions
Internal Access Failed
Internal Database Error

 

SROF

Get IOR Failed

RTRV-ALM-ENV

IIAC

Invalid AID

 

SDBE

Cannot Access Conditions
Internal Database Error

 

SROF

Get IOR Failed

 

SRQN

Invalid Request

RTRV-ALM-EQPT

ENEQ

Equipment Not Found
Equipment Not Present

 

IIAC

Invalid AID

 

SDBE

Cannot Access Conditions
Cannot Access Equipment
Internal Access Failed
Internal Database Error

 

SROF

Get IOR Failed

 

SRQN

Invalid Request

RTRV-ALM-G1000

ENEQ

Equipment Not Found

 

IDNC

Invalid Data

 

IIAC

Equipment Does Not Match Request
Invalid AID

 

SDBE

Internal Access Failed
Internal Database Error

 

SROF

Get IOR Failed

RTRV-ALM-RING

IIAC

Invalid AID

 

SDBE

Internal Database Error

 

SROF

Cannot Access BLSR
Get IOR Failed

 

SRQN

BLSR Does Not Exist

RTRV-ALM-T1

ENEQ

Equipment Not Found

 

ICNV

Invalid Command

 

IIAC

Equipment Does Not Match Request
Invalid AID
Invalid DS1 AID

 

IICM

Input, Invalid Command

 

SDBE

Cannot Access Conditions
Internal Access Failed
Internal Database Error

 

SROF

Get IOR Failed

RTRV-ALM-T3

ENEQ

Equipment Not Found

 

ICNV

Invalid Command

 

IIAC

Equipment Does Not Match Request
Invalid AID
Invalid DS1 AID

 

IICM

Input, Invalid Command

 

SDBE

Cannot Access Conditions
Internal Access Failed
Internal Database Error

 

SROF

Get IOR Failed

RTRV-ALM-SYNCN

SROF

Get IOR Failed

 

SDBE

Cannot Access Conditions
Internal Database Error

 

IIAC

Invalid AID

RTRV-ALM-UCP

IICM

Input, Invalid Command

 

SDBE

Internal Database Error

 

SROF

Get IOR Failed

RTRV-ALM-UDCDCC

IIAC

Invalid AID

 

SDBE

Cannot Access Conditions
Internal Database Error

 

SROF

Get IOR Failed

 

SRQN

Invalid Request

RTRV-ALM-UDCF

IIAC

Invalid AID

 

SDBE

Cannot Access Conditions
Internal Database Error

 

SROF

Get IOR Failed

 

SRQN

Invalid Request

RTRV-ALM-VT1

ICNV

Invalid Command

 

IIAC

Equipment Does Not Match Request
Invalid AID

 

IICM

Input, Invalid Command

 

SDBE

Cannot Access Conditions
Internal Database Error

 

SROF

Get IOR Failed

RTRV-ATTR-CONT

IIAC

Invalid AID

 

SDBE

Cannot Access Controls
Internal Database Error

 

SROF

Get IOR Failed

 

SRQN

Invalid Request

RTRV-ATTR-ENV

IIAC

Invalid AID

 

SDBE

Cannot Access Environmental Settings
Internal Database Error

 

SROF

Get IOR Failed

 

SRQN

Invalid Request

RTRV-BITS

IIAC

Invalid AID

 

SDBE

Internal Database Error

 

SROF

Get IOR Failed

RTRV-BLSR

IIAC

Invalid AID

 

SDBE

Internal Database Error

 

SROF

Cannot Access BLSR
Get IOR Failed

 

SRQN

BLSR Does Not Exist

RTRV-COND-<OCN_TYPE>

ENEQ

Equipment Not Found

 

IDNC

Invalid Data

 

IIAC

Equipment Does Not Match Request
Invalid AID

 

IICM

Input, Invalid Command

 

SDBE

Cannot Access Object
Internal Access Failed
Internal Database Error

 

SROF

Get IOR Failed

RTRV-COND-<STS_PATH>

IIAC

Invalid AID

 

IICM

Input, Invalid Command

 

SDBE

Cannot Access Object
Cannot Access STS
Internal Database Error
STS Not Provisioned

 

SROF

Get IOR Failed

RTRV-COND-ALL

ENEQ

Equipment Not Found

 

IIAC

Invalid AID

 

RRNG

Invalid Slot Number

 

SDBE

Cannot Access Object
Internal Access Failed
Internal Database Error

 

SROF

Get IOR Failed

RTRV-COND-BITS

IIAC

Invalid AID

 

SROF

Get IOR Failed

RTRV-COND-DS1

ENEQ

Equipment Not Found

 

ICNV

Invalid Command

 

IIAC

Equipment Does Not Match Request
Invalid AID
Invalid DS1 AID

 

IICM

Input, Invalid Command

 

SDBE

Cannot Access Object
Internal Access Failed
Internal Database Error

 

SROF

Get IOR Failed

RTRV-COND-E100

ENEQ

Equipment Not Found

 

IDNC

Invalid Data

 

IIAC

Equipment Does Not Match Request
Invalid AID

 

SDBE

Cannot Access Object
Internal Access Failed
Internal Database Error

 

SROF

Get IOR Failed

RTRV-COND-E1000

ENEQ

Equipment Not Found

 

IDNC

Invalid Data

 

IIAC

Equipment Does Not Match Request
Invalid AID

 

SDBE

Cannot Access Object
Internal Access Failed
Internal Database Error

 

SROF

Get IOR Failed

RTRV-COND-EC1

ENEQ

Equipment Not Found

 

IDNC

Invalid Data

 

IIAC

Equipment Does Not Match Request
Invalid AID

 

IICM

Input, Invalid Command

 

SDBE

Cannot Access Object
Internal Access Failed
Internal Database Error

 

SROF

Get IOR Failed

RTRV-COND-ENV

IIAC

Invalid AID

 

SDBE

Cannot Access Object
Internal Database Error

 

SROF

Get IOR Failed

 

SRQN

Invalid Request

RTRV-COND-EQPT

ENEQ

Equipment Not Found
Equipment Not Present

 

IIAC

Invalid AID

 

SDBE

Cannot Access Equipment
Cannot Access Object
Internal Access Failed
Internal Database Error

 

SROF

Get IOR Failed

 

SRQN

Invalid Request

RTRV-COND-G1000

ENEQ

Equipment Not Found

 

IDNC

Invalid Data

 

IIAC

Equipment Does Not Match Request
Invalid AID

 

SDBE

Cannot Access Object
Internal Access Failed
Internal Database Error

 

SROF

Get IOR Failed

RTRV-COND-RING

IIAC

Invalid AID

 

SDBE

Internal Database Error

 

SROF

Cannot Access BLSR
Get IOR Failed

 

SRQN

BLSR Does Not Exist

RTRV-COND-T1

ENEQ

Equipment Not Found

 

ICNV

Invalid Command

 

IIAC

Equipment Does Not Match Request
Invalid AID
Invalid DS1 AID

 

IICM

Input, Invalid Command

 

SDBE

Cannot Access Object
Internal Access Failed
Internal Database Error

 

SROF

Get IOR Failed

RTRV-COND-T3

ENEQ

Equipment Not Found

 

ICNV

Invalid Command

 

IIAC

Equipment Does Not Match Request
Invalid AID
Invalid DS1 AID

 

IICM

Input, Invalid Command

 

SDBE

Cannot Access Object
Internal Access Failed
Internal Database Error

 

SROF

Get IOR Failed

RTRV-COND-SYNCN

IIAC

Invalid AID

 

SDBE

Internal Database Error

 

SROF

Get IOR Failed

RTRV-COND-UCP

IICM

Input, Invalid Command

 

SDBE

Internal Database Error

 

SROF

Get IOR Failed

RTRV-COND-UDCDCC

IIAC

Invalid AID

 

SDBE

Cannot Access Object
Internal Database Error

 

SROF

Get IOR Failed

 

SRQN

Invalid Request

RTRV-COND-UDCF

IIAC

Invalid AID

 

SDBE

Cannot Access Object
Internal Database Error

 

SROF

Get IOR Failed

 

SRQN

Invalid Request

RTRV-COND-VT1

ICNV

Invalid Command

 

IIAC

Equipment Does Not Match Request
Invalid AID

 

SDBE

Cannot Access Object
Internal Database Error

 

SROF

Get IOR Failed

RTRV-CRS

ENEQ

Equipment Not Found

 

IIAC

Invalid AID

 

RRNG

Invalid Slot Number

 

SDBE

Internal Access Failed
Internal Database Error

 

SROF

Cannot Access 1+1 Line
Cannot Access 1+1 Protected Line
Cannot Access 4F BLSR
Cannot Access BLSR 2 Wire Line
Cannot Access Cross-Connection
Cannot Access Unprotected Line
Element Not Found
Get IOR Failed
Requested Operation Failed
Unsupported Element Type

RTRV-CRS-<STS_PATH>

ENEQ

Equipment Not Found

 

IIAC

Invalid AID

 

IICM

Input, Invalid Command

 

RRNG

Invalid Slot Number

 

SDBE

Internal Access Failed
Internal Database Error

 

SROF

Cannot Access Cross-Connection
Get IOR Failed

RTRV-CRS-VT1

ENEQ

Equipment Not Found

 

IIAC

Invalid AID

 

IICM

Input, Invalid Command

 

RRNG

Invalid Slot Number

 

SDBE

Internal Access Failed
Internal Database Error

 

SROF

Cannot Access Cross-Connection
Get IOR Failed

RTRV-DS1

ENEQ

Equipment Not Found

 

ICNV

Invalid Command

 

IIAC

Equipment Does Not Match Request
Invalid AID
Invalid DS1 AID

 

IICM

Input, Invalid Command

 

IPNV

Invalid Parameter

 

SDBE

Cannot Access Object
Internal Access Failed
Internal Database Error

 

SROF

Get IOR Failed

RTRV-EC1

ENEQ

Equipment Not Found

 

IDNC

Invalid Data

 

IIAC

Equipment Does Not Match Request
Invalid AID

 

IICM

Input, Invalid Command

 

SDBE

Facility Does Not Exist
Incorrect Facility Type
Internal Access Failed
Internal Database Error

 

SROF

Get IOR Failed

RTRV-EQPT

ENEQ

Equipment Not Found
Equipment Not Present

 

IIAC

Invalid AID

 

SDBE

Cannot Access Equipment
Cannot Access Protection Group
Internal Access Failed
Internal Database Error

 

SNVS

Invalid Admin State
Protection Group Does Not Exist

RTRV-EQPT (continued)

SROF

Cannot Access Cross-connect
Cannot Access Protection Group Information
Cannot Access Protection Group Name
Get IOR Failed

 

SRQN

Invalid Request

RTRV-EXT-CONT

IIAC

Invalid AID

 

SDBE

Cannot Access Controls
Internal Database Error

 

SROF

Get IOR Failed

 

SRQN

Invalid Request

RTRV-FFP-<OCN_TYPE>

ENEQ

Equipment Not Found

 

IDNC

Invalid Data

 

IIAC

Equipment Does Not Match Request
Invalid AID

 

IICM

Input, Invalid Command

 

SDBE

Cannot Access Protection Group
Internal Access Failed
Internal Database Error

 

SROF

1+1 Protection Group Not Found
Cannot Access Facility
Cannot Access Protection Group Name
Facility Not Provisioned
Get IOR Failed

RTRV-G1000

ENEQ

Equipment Not Found
Equipment Not Present

 

ICNV

Invalid Command

 

IIAC

Invalid AID
Invalid G1000 Facility Port

 

SDBE

Cannot Access Equipment
Internal Access Failed
Internal Database Error
Object Not Provisioned

 

SROF

Get IOR Failed

RTRV-INV

ENEQ

Equipment Not Found
Equipment Not Present

 

IIAC

Invalid AID
List AID Not Allowed For ALL AID

 

SDBE

Cannot Access Equipment
Internal Access Failed
Internal Database Error

 

SROF

Get IOR Failed

 

SRQN

Invalid Request

RTRV-LOG

IDNV

Invalid Log Name

 

SDBE

Internal Database Error

 

SROF

Cannot Access Alarm Log
Get IOR Failed

RTRV-MAP-NETWORK

IPNV

Internal-Ip Lookup Failed

 

SDBE

Cannot Access IP Configuration
Internal Database Error

 

SROF

DCC Not In Use
Get IOR Failed

RTRV-NE-GEN

SDBE

Cannot Access Defaults Description
Cannot Access IP Configuration
Cannot Access Node ID
Cannot Access SNTP Host
Cannot Access Software Version
Cannot Access Synchronization Configuration
Internal Database Error

 

SROF

Cannot Access LAN IP Configuration
Get IOR Failed

RTRV-NE IPMAP

ENEQ

Equipment Not Found

 

IIAC

Equipment Does Not Match Request
Invalid AID

 

IPNV

Invalid IP Address

 

SDBE

Cannot Access IP Configuration
Internal Access Failed
Internal Database Error

 

SROF

DCC Not In Use
Get IOR Failed

RTRV-NE-SYNCN

SDBE

Cannot Access Synchronization Configuration
Internal Database Error

 

SROF

Get IOR Failed

RTRV-PM-<OCN_TYPE>

ENEQ

Equipment Not Found
Equipment Not Present

 

IDNC

Invalid Data

 

IDNV

Interval Out Of Range
Invalid MONLEV Value
Invalid MONTYPE Value

 

IIAC

Equipment Does Not Match Request
Invalid AID

 

IICM

Input, Invalid Command

RTRV-PM-<OCN_TYPE> (continued)

SDBE

Cannot Access Equipment
Facility Does Not Exist
Internal Access Failed
Internal Database Error

 

SNCN

This Direction Is Not Supported

 

SROF

Cannot Access Performance Monitoring Statistics
Get IOR Failed

RTRV-PM-<STS_PATH>

ENEQ

Equipment Not Found
Equipment Not Present
Internal Communication Error

 

IDNV

Interval Out Of Range
Invalid MONLEV Value
Invalid MONTYPE Value

 

IIAC

Invalid AID

 

IICM

Input, Invalid Command

 

IPNV

Far End Performance Monitoring Values Not Supported

 

SDBE

Cannot Access Equipment
Cannot Access STS
Internal Access Failed
Internal Database Error
STS Not Provisioned

 

SNCN

This Direction Is Not Supported

 

SROF

Get IOR Failed

RTRV-PM-DS1

ENEQ

Equipment Not Found
Equipment Not Present
Equipment Not Provisioned
Internal Communication Error

 

ICNV

Invalid Command

 

IDNV

Incompatible Equipment Type
Interval Out Of Range
Invalid MONLEV Value
Invalid MONTYPE Value

 

IIAC

Equipment Does Not Match Request
Invalid AID
Invalid DS1 AID

 

IICM

Input, Invalid Command

 

IPNV

Far End Performance Monitoring Values Not Supported
PM Not Supported

RTRV-PM-DS1 (continued)

SDBE

Cannot Access Equipment
Cannot Access Object
Card Type Not Supported
Internal Access Failed
Internal Database Error

 

SNCN

This Direction Is Not Supported

 

SROF

Equipment Does Not Match Request
Get IOR Failed

RTRV-PM-EC1

ENEQ

Equipment Not Found
Equipment Not Present

 

IDNC

Invalid Data

 

IDNV

Interval Out Of Range
Invalid MONLEV Value
Invalid MONTYPE Value

 

IIAC

Equipment Does Not Match Request
Invalid AID

 

IICM

Input, Invalid Command

 

SDBE

Cannot Access Equipment
Facility Does Not Exist
Internal Access Failed
Internal Database Error

 

SNCN

This Direction Is Not Supported

 

SROF

Cannot Access Performance Monitoring Statistics
Get IOR Failed

RTRV-PM-T1

ENEQ

Equipment Not Found
Equipment Not Present
Equipment Not Provisioned
Internal Communication Error

 

ICNV

Invalid Command

 

IDNV

Incompatible Equipment Type
Interval Out Of Range
Invalid MONLEV Value
Invalid MONTYPE Value

 

IIAC

Equipment Does Not Match Request
Invalid AID
Invalid DS1 AID

 

IICM

Input, Invalid Command

 

IPNV

Far End Performance Monitoring Values Not Supported
PM Not Supported

RTRV-PM-T1 (continued)

SDBE

Cannot Access Equipment
Cannot Access Object
Card Type Not Supported
Internal Access Failed
Internal Database Error

 

SNCN

This Direction Is Not Supported

 

SROF

Equipment Does Not Match Request
Get IOR Failed

RTRV-PM-T3

ENEQ

Equipment Not Found
Equipment Not Present
Equipment Not Provisioned
Internal Communication Error

 

ICNV

Invalid Command

 

IDNV

Incompatible Equipment Type
Interval Out Of Range
Invalid MONLEV Value
Invalid MONTYPE Value

 

IIAC

Equipment Does Not Match Request
Invalid AID
Invalid DS1 AID

 

IICM

Input, Invalid Command

 

IPNV

Far End Performance Monitoring Values Not Supported
PM Not Supported

 

SDBE

Cannot Access Equipment
Cannot Access Object
Card Type Not Supported
Internal Access Failed
Internal Database Error

 

SNCN

This Direction Is Not Supported

 

SROF

Equipment Does Not Match Request
Get IOR Failed

RTRV-PM-VT1

ENEQ

Equipment Not Found
Equipment Not Present

 

ICNV

Invalid Command
Operation not supported by this card

 

IDNV

Interval Out Of Range
Invalid MONLEV Value
Invalid MONTYPE Value

 

IIAC

Equipment Does Not Match Request
Invalid AID

 

IICM

Input, Invalid Command

RTRV-PM-VT1 (continued)

SDBE

Cannot Access Equipment
Cannot Access VT
Internal Access Failed
Internal Database Error
VT Not Provisioned

 

SNCN

This Direction Is Not Supported

 

SROF

Get IOR Failed
Operation Not Supported

RTRV-PMMODE-<STS_PATH>

IIAC

Invalid AID

 

IICM

Input, Invalid Command

 

SDBE

Cannot Access STS
Internal Database Error
STS Not Provisioned

 

SROF

Get IOR Failed

RTRV-PMSCHED-<OCN_TYPE>

IIAC

Invalid AID

 

IICM

Input, Invalid Command

 

SDBE

Operation not supported by this card
Internal Database Error

 

SSRE

Memory Resources Exceeded

RTRV-PMSCHED-<STS_TYPE>

IIAC

Invalid AID

 

IICM

Input, Invalid Command

 

SDBE

Operation not supported by this card
Internal Database Error

 

SSRE

Memory Resources Exceeded

RTRV-PMSCHED-ALL

IIAC

Invalid AID

 

SDBE

Operation not supported by this card
Internal Database Error

 

SSRE

Memory Resources Exceeded

RTRV-PMSCHED-DS1

IIAC

Invalid AID

 

SDBE

Operation not supported by this card
Internal Database Error

 

SSRE

Memory Resources Exceeded

RTRV-PMSCHED-EC1

IIAC

Invalid AID

 

IICM

Input, Invalid Command

 

SDBE

Operation not supported by this card
Internal Database Error

 

SSRE

Memory Resources Exceeded

RTRV-PMSCHED-T1

IIAC

Invalid AID

 

SDBE

Operation not supported by this card
Internal Database Error

 

SSRE

Memory Resources Exceeded

RTRV-PMSCHED-T3

IIAC

Invalid AID

 

SDBE

Operation not supported by this card
Internal Database Error

 

SSRE

Memory Resources Exceeded

RTRV-PMSCHED-VT1

IIAC

Invalid AID

 

SDBE

Operation not supported by this card
Internal Database Error

 

SSRE

Memory Resources Exceeded

RTRV-PROTNSW-<OCN_TYPE>

ENEQ

Equipment Not Found

 

IDNC

Invalid Data

 

IIAC

Equipment Does Not Match Request
Invalid AID

 

SDBE

Internal Access Failed
Internal Database Error

 

SROF

Cannot Access Facility
Facility Not Provisioned
Get IOR Failed

RTRV-PROTNSW-<STS_TYPE>

ENEQ

Equipment Not Found

 

IDNV

Multiple AIDs Not Allowed

 

IIAC

Invalid AID
Invalid Aid
AID Validation Failed
Invalid AID

 

RRNG

Invalid Slot Number

 

SDBE

Cannot Access STS
Internal Access Failed
Internal Database Error
STS Not Provisioned

 

SROF

Cannot Access Cross-Connection
Get IOR Failed
STS Rates Do Not Match

 

SSRD

Switch Request Denied

RTRV-PROTNSW-VT1

ENEQ

Equipment Not Found

 

ICNV

Invalid Command

 

IIAC

Equipment Does Not Match Request
Invalid AID

 

RRNG

Invalid Slot Number

 

SDBE

Internal Access Failed
Internal Database Error

 

SROF

Cannot Access Cross-Connection
Get IOR Failed
Requested Operation Failed

 

SSRD

Switch Request Denied

RTRV-PTHTRC-<STS_PATH>

ENEQ

Equipment Not Found
Equipment Not Present

 

IDNV

Multiple AIDs Not Allowed

 

IIAC

Invalid AID
Invalid Aid
Expected Trace Not Supported On This Card Type
Incoming Trace Not Supported On This Card Type
Invalid AID
Trace Not Supported On This Card Type

 

IICM

Input, Invalid Command

 

IIDT

Invalid Location Value

 

RRNG

Invalid Slot Number

 

SDBE

Cannot Access STS
Internal Data Base Error
STS Is Not Provisioned
Cannot Access Equipment
Cannot Access STS
Internal Access Failed
Internal Database Error
STS Not Provisioned

 

SOSE

Unrecognized Message Type

 

SROF

Get IOR Failed

RTRV-SYNCN

IIAC

Invalid AID

 

SDBE

Internal Data Base Error
Internal Database Error

 

SROF

Get IOR Failed

RTRV-T1

ENEQ

Equipment Not Found

 

ICNV

Invalid Command

 

IIAC

Equipment Does Not Match Request
Invalid AID
Invalid DS1 AID

 

IICM

Input, Invalid Command

 

IPNV

Invalid Parameter

 

SDBE

Cannot Access Object
Internal Access Failed
Internal Database Error

 

SROF

Get IOR Failed

RTRV-T3

ENEQ

Equipment Not Found

 

ICNV

Invalid Command

 

IIAC

Equipment Does Not Match Request
Invalid AID
Invalid DS1 AID

 

IICM

Input, Invalid Command

 

IPNV

Invalid Parameter

 

SDBE

Cannot Access Object
Internal Access Failed
Internal Database Error

 

SROF

Get IOR Failed

RTRV-TACC

IDNV

Multiple AIDs Not Allowed

 

IIAC

Invalid AID

 

SROF

Tap Not Provisioned
Tap Number Does Not Exist
Unknown Internal Error

RTRV-TH-<OCN_TYPE>

ENEQ

Equipment Not Found

 

ICNV

Pm Not Supported
Performance Monitoring Type Not Supported

 

IDNC

Invalid Data

 

IIAC

Equipment Does Not Match Request
Invalid AID

 

IICM

Input, Invalid Command

 

IPNC

Invalid Parameter

 

SDBE

Facility Does Not Exist
Internal Access Failed
Internal Database Error

 

SROF

Cannot Access Performance Monitoring Statistics
Get IOR Failed

RTRV-TH-<STS_PATH>

ENEQ

Internal Communication Error

 

ICNV

Performance Monitoring Type Not Supported

 

IIAC

Invalid AID

 

IICM

Input, Invalid Command

 

IPNV

Far End Performance Monitoring Values Not Supported

 

SDBE

Cannot Access STS
Internal Database Error
STS Not Provisioned

 

SROF

Get IOR Failed

RTRV-TH-DS1

ENEQ

Equipment Not Found
Equipment Not Provisioned
Internal Communication Error

 

ICNV

Invalid Command

 

IDNV

Incompatible Equipment Type

 

IIAC

Equipment Does Not Match Request
Invalid AID
Invalid DS1 AID

 

IICM

Input, Invalid Command

 

IPNV

Far End Performance Monitoring Values Not Supported
Invalid Parameter
PM Not Supported

 

SDBE

Cannot Access Object
Internal Access Failed
Internal Database Error

 

SROF

Get IOR Failed

RTRV-TH-EC1

ENEQ

Equipment Not Found

 

ICNV

Pm Not Supported
Performance Monitoring Type Not Supported

 

IDNC

Invalid Data

 

IIAC

Equipment Does Not Match Request
Invalid AID

 

IICM

Input, Invalid Command

 

IPNC

Invalid Parameter

 

SDBE

Facility Does Not Exist
Internal Access Failed
Internal Database Error

 

SROF

Cannot Access Performance Monitoring Statistics
Get IOR Failed

RTRV-TH-T1

ENEQ

Equipment Not Found
Equipment Not Provisioned
Internal Communication Error

 

ICNV

Invalid Command

 

IDNV

Incompatible Equipment Type

 

IIAC

Invalid AID

 

IICM

Input, Invalid Command

 

IPNV

Far End Performance Monitoring Values Not Supported
Invalid Parameter
PM Not Supported

 

SDBE

Cannot Access Object
Internal Access Failed
Internal Database Error

 

SROF

Get IOR Failed

RTRV-TH-T3

ENEQ

Equipment Not Found
Equipment Not Provisioned
Internal Communication Error

 

ICNV

Invalid Command

 

IDNV

Incompatible Equipment Type

 

IIAC

Equipment Does Not Match Request
Invalid AID
Invalid DS1 AID

 

IPNV

Far End Performance Monitoring Values Not Supported
Invalid Parameter
PM Not Supported

 

SDBE

Cannot Access Object
Internal Access Failed
Internal Database Error

 

SROF

Get IOR Failed

RTRV-TH-VT1

ICNV

Invalid Command
Operation not supported by this card
Performance Monitoring Type Not Supported

 

IIAC

Equipment Does Not Match Request
Invalid AID

 

IICM

Input, Invalid Command

 

SDBE

Cannot Access VT
Cannot Access VT Performance Monitoring Parameters
Internal Database Error
VT Not Provisioned

RTRV-TH-VT1 (continued)

SROF

Get IOR Failed
Operation Not Supported

RTRV-TOD

SDBE

Cannot Access Date/Time
Cannot Access Timezone\
Internal Database Error

 

SROF

Get IOR Failed

RTRV-UCP-CC

IICM

Input, Invalid Command

 

SDBE

Internal Database Error

 

SROF

Get IOR Failed

RTRV-UCP-IF

IICM

Input, Invalid Command

 

SDBE

Internal Database Error

 

SROF

Get IOR Failed

RTRV-UCP-NBR

IICM

Input, Invalid Command

 

SDBE

Internal Database Error

 

SROF

Get IOR Failed

RTRV-UCP-NODE

IICM

Input, Invalid Command

 

SDBE

Internal Database Error

 

SROF

Get UCP Node Interface Failed

RTRV-USER-SECU

IIAC

Invalid AID

 

PICC

AID Required
Unknown CORBA Exception (Internal Error)
Unknown User
User Identifier Exceeds Maximum Length Allowed

 

PIUC

User Is Not Superuser

 

SDBE

Internal Database Error

 

SROF

Get IOR Failed

RTRV-VT1

ENEQ

Equipment Not Found

 

ICNV

Invalid Command

 

IIAC

Equipment Does Not Match Request
Invalid AID

 

IICM

Input, Invalid Command

 

RRNG

Invalid Slot Number

 

SDBE

Cannot Access STS
Cannot Access VT
Internal Access Failed
Internal Database Error
STS Not Provisioned
VT Not Provisioned

RTRV-VT1 (continued)

SROF

Cannot Access Cross-Connection
Get IOR Failed

SCHED-PMREPT-<OCN_TYPE>

IDNV

Invalid MONLEV Value
Invalid Report Interval
Invalid Start Time
Number Of Reports Is Negative

 

IIAC

Invalid AID

 

IICM

Input, Invalid Command

 

IIDT

Duplicate Performance Monitoring Schedule
Maximum Performance Monitoring Schedule Limit Reached
Performance Monitoring Schedule Does Not Exist

 

IPNV

Far End Performance Monitoring Values Not Supported

 

SDBE

Operation not supported by this card
Internal Database Error

 

SSRE

Memory Resources Exceeded

SCHED-PMREPT-<STS_PATH>

IDNV

Invalid MONLEV Value
Invalid Report Interval
Invalid Start Time
Number Of Reports Is Negative

 

IIAC

Invalid AID

 

IICM

Input, Invalid Command

 

IIDT

Duplicate Performance Monitoring Schedule
Maximum Performance Monitoring Schedule Limit Reached
Performance Monitoring Schedule Does Not Exist

 

IPNV

Far End Performance Monitoring Values Not Supported

 

SDBE

Operation not supported by this card
Internal Database Error

 

SSRE

Memory Resources Exceeded

SCHED-PMREPT-DS1

IDNV

Invalid MONLEV Value
Invalid Report Interval
Invalid Start Time
Number Of Reports Is Negative

 

IIAC

Invalid AID

 

IIDT

Duplicate Performance Monitoring Schedule
Maximum Performance Monitoring Schedule Limit Reached
Performance Monitoring Schedule Does Not Exist

 

IPNV

Far End Performance Monitoring Values Not Supported

SCHED-PMREPT-DS1 (continued)

SDBE

Operation not supported by this card
Internal Database Error

 

SSRE

Memory Resources Exceeded

SCHED-PMREPT-EC1

IDNV

Invalid MONLEV Value
Invalid Report Interval
Invalid Start Time
Number Of Reports Is Negative

 

IIAC

Invalid AID

 

IICM

Input, Invalid Command

 

IIDT

Duplicate Performance Monitoring Schedule
Maximum Performance Monitoring Schedule Limit Reached
Performance Monitoring Schedule Does Not Exist

 

IPNV

Far End Performance Monitoring Values Not Supported

 

SDBE

Operation not supported by this card
Internal Database Error

 

SSRE

Memory Resources Exceeded

SCHED-PMREPT-T1

IDNV

Invalid MONLEV Value
Invalid Report Interval
Invalid Start Time
Number Of Reports Is Negative

 

IIAC

Invalid AID

 

IIDT

Duplicate Performance Monitoring Schedule
Maximum Performance Monitoring Schedule Limit Reached
Performance Monitoring Schedule Does Not Exist

 

IPNV

Far End Performance Monitoring Values Not Supported

 

SDBE

Operation not supported by this card
Internal Database Error

 

SSRE

Memory Resources Exceeded

SCHED-PMREPT-T3

IDNV

Invalid MONLEV Value
Invalid Report Interval
Invalid Start Time
Number Of Reports Is Negative

 

IIAC

Invalid AID

 

IIDT

Duplicate Performance Monitoring Schedule
Maximum Performance Monitoring Schedule Limit Reached
Performance Monitoring Schedule Does Not Exist

 

IPNV

Far End Performance Monitoring Values Not Supported

SCHED-PMREPT-T3 (continued)

SDBE

Operation not supported by this card
Internal Database Error

 

SSRE

Memory Resources Exceeded

SCHED-PMREPT-VT1

IDNV

Invalid MONLEV Value
Invalid Report Interval
Invalid Start Time
Number Of Reports Is Negative

 

IIAC

Invalid AID

 

IIDT

Duplicate Performance Monitoring Schedule
Maximum Performance Monitoring Schedule Limit Reached
Performance Monitoring Schedule Does Not Exist

 

IPNV

Far End Performance Monitoring Values Not Supported

 

SDBE

Operation not supported by this card
Internal Database Error

 

SSRE

Memory Resources Exceeded

SET-ATTR-CONT

IIAC

Invalid AID

 

SDBE

Cannot Access Controls
Internal Database Error

 

SROF

Get IOR Failed

 

SRQN

Invalid Request

SET-ATTR-ENV

IIAC

Invalid AID

 

IPNC

Description Cannot Have More Than 64 Characters

 

IPNV

Invalid Parameter

 

SDBE

Cannot Access Environmental Settings
Internal Database Error

 

SROF

Get IOR Failed

 

SRQN

Invalid Request

SET-PMMODE-<STS_PATH>

IICM

Input, Invalid Command

 

ENEQ

Equipment Not Found

 

ICNV

Pm Not Supported
Performance Monitoring Type Not Supported

 

IDNC

Invalid Data

 

IDRG

Invalid Threshold Value

 

IIAC

Equipment Does Not Match Request
Invalid AID

 

IICM

Input, Invalid Command

 

IPNV

Invalid Parameter

SET-PMMODE-<STS_PATH> (continued)

SDBE

Facility Does Not Exist
Facility Does Not Match Request
Internal Access Failed
Internal Database Error

 

SROF

Cannot Access Performance Monitoring Statistics
Get IOR Failed

SET-TH-<OCN_TYPE>

ICNV

Pm Not Supported
Performance Monitoring Type Not Supported

 

ENEQ

Equipment Not Found

 

SROF

Cannot Access Performance Monitoring Statistics
Get IOR Failed

 

IICM

Input, Invalid Command

 

IPNV

Invalid Parameter

 

SDBE

Facility Does Not Exist
Facility Does Not Match Request
Internal Access Failed
Internal Database Error

 

IDNC

Invalid Data

 

IDRG

Invalid Threshold Value

 

IIAC

Equipment Does Not Match Request
Invalid AID

SET-TH-<STS_PATH>

ENEQ

Internal Communication Error

 

ICNV

Performance Monitoring Type Not Supported

 

IDRG

Invalid Threshold Value

 

IIAC

Cannot Make Changes To Protect Card
Invalid AID

 

IICM

Input, Invalid Command

 

IPNV

Far End Performance Monitoring Values Not Supported

 

SDBE

Cannot Access STS
Internal Database Error
STS Not Provisioned

 

SROF

Cannot Access Performance Monitoring Statistics
Get IOR Failed

SET-TH-DS1

ENEQ

Equipment Not Found
Equipment Not Provisioned
Internal Communication Error

 

ICNV

Invalid Command

 

IDNV

Incompatible Equipment Type

 

IDRG

Threshold Out Of Range

SET-TH-DS1 (continued)

IIAC

Cannot Make Changes To Protect Card
Equipment Does Not Match Request
Invalid AID
Invalid DS1 AID

 

IICM

Input, Invalid Command

 

IPNV

Invalid Parameter
PM Not Supported

 

SDBE

Cannot Access Object
Internal Access Failed
Internal Database Error

 

SROF

Get IOR Failed

SET-TH-EC1

ENEQ

Equipment Not Found

 

ICNV

Pm Not Supported
Performance Monitoring Type Not Supported

 

IDNC

Invalid Data

 

IDRG

Invalid Threshold Value

 

IIAC

Equipment Does Not Match Request
Invalid AID

 

IICM

Input, Invalid Command

 

IPNV

Invalid Parameter

 

SDBE

Facility Does Not Exist
Facility Does Not Match Request
Internal Access Failed
Internal Database Error

 

SROF

Cannot Access Performance Monitoring Statistics
Get IOR Failed

SET-TH-T1

ENEQ

Equipment Not Found
Equipment Not Provisioned
Internal Communication Error

 

ICNV

Invalid Command

 

IDNV

Incompatible Equipment Type

 

IDRG

Threshold Out Of Range

 

IIAC

Cannot Make Changes To Protect Card
Equipment Does Not Match Request
Invalid AID
Invalid DS1 AID

 

IICM

Input, Invalid Command

 

IPNV

Invalid Parameter
PM Not Supported

 

SDBE

Cannot Access Object
Internal Access Failed
Internal Database Error

SET-TH-T1 (continued)

SROF

Get IOR Failed

SET-TH-T3

ENEQ

Equipment Not Found
Equipment Not Provisioned
Internal Communication Error

 

ICNV

Invalid Command

 

IDNV

Incompatible Equipment Type

 

IDRG

Threshold Out Of Range

 

IIAC

Cannot Make Changes To Protect Card
Equipment Does Not Match Request
Invalid AID
Invalid DS1 AID

 

IICM

Input, Invalid Command

 

IPNV

Invalid Parameter
PM Not Supported

 

SDBE

Cannot Access Object
Internal Access Failed
Internal Database Error

 

SROF

Get IOR Failed

SET-TH-VT1

ICNV

Invalid Command
Operation not supported by this card
Performance Monitoring Type Not Supported

 

IIAC

Cannot Make Changes To Protect Card
Equipment Does Not Match Request
Invalid AID

 

IICM

Input, Invalid Command

 

IPNV

Invalid Parameter

 

SDBE

Cannot Access VT
Cannot Access VT Performance Monitoring Parameters
Internal Database Error
VT Not Provisioned

 

SROF

Get IOR Failed
Operation Not Supported

SET-TOD

IDRG

Difference Value Range Error

 

IIAC

Invalid Month Or Day
Invalid Time
Invalid Year

 

SDBE

Cannot Access Date/Time
Cannot Access Timezone
Cannot Set Date
Cannot Set Date When Using SNTP
Cannot Set Timezone
Internal Database Error

SET-TOD (continued)

SROF

Get IOR Failed

SW-DX-EQPT

ENEQ

Equipment Not Found

 

IIAC

Invalid AID

 

IICM

Input, Invalid Command

 

SDBE

Internal Access Failed
Internal Database Error

 

SROF

Get IOR Failed

 

SRQN

Invalid Request

SW-TOPROTN-EQPT

ENEQ

Equipment Not Found

 

IDNV

Input, Data Not Valid
Invalid Protid

 

IIAC

Input, Invalid Access
Invalid AID

 

IICM

Input, Invalid Command

 

SAAL

Already Allowed

 

SDBE

Cannot Access Protection Group
Internal Access Failed
Internal Database Error

 

SNVS

Protection Group Does Not Exist
Working Unit Already Active
Working Unit Already Standby

 

SROF

Cannot Access Protection Group Information
Cannot Access Protection Group Name
Get IOR Failed

 

SRQN

Invalid Request

SW-TOWKG-EQPT

ENEQ

Equipment Not Found

 

IDNV

Input, Data Not Valid
Invalid Protid

 

IIAC

Input, Invalid Access
Invalid AID

 

IICM

Input, Invalid Command

 

SAAL

Already Allowed

 

SDBE

Cannot Access Protection Group
Internal Access Failed
Internal Database Error

 

SNVS

Protection Group Does Not Exist
Working Unit Already Active
Working Unit Already Standby

SW-TOWKG-EQPT (continued)

SROF

Cannot Access Protection Group Information
Cannot Access Protection Group Name
Get IOR Failed

 

SRQN

Invalid Request


7.3 Echo

In order to improve telnet functionality for automated systems, the echo function has been turned off since ONS 15454 Release 3.0. This change is transparent to users running standard UNIX-compliant telnet clients; however, PC users may need to change their client setup to enable "local echo." This is normally accomplished by a pull-down menu or a preference attribute.

To test the local echo on your PC client, use the RTRV-HDR command. If you receive a response but no data, set local echo ON. Cisco recommends that you close any windows containing sensitive information after exiting a TL1 session.