cc/td/doc/product/ong/15400/r34docs
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table Of Contents

Optical Cards

4.1 Card Overview

4.1.1 Optical Cards

4.1.2 Card Power Requirements

4.1.3 Card Temperature Ranges

4.2 OC3 IR 4/STM1 SH 1310 Card

4.2.1 OC3 IR 4/STM1 SH 1310 Card-Level Indicators

4.2.2 OC3 IR 4/STM1 SH 1310 Port-Level Indicators

4.2.3 OC3 IR 4/STM1 SH 1310 Card Specifications

4.3 OC12 IR/STM4 SH 1310 Card

4.3.1 OC12 IR/STM4 SH 1310 Card-Level Indicators

4.3.2 OC12 IR/STM4 SH 1310 Port-Level Indicators

4.3.3 OC12 IR/STM4 SH 1310 Card Specifications

4.4 OC12 LR/STM4 LH 1310 Card

4.4.1 OC12 LR/STM4 LH 1310 Card-Level Indicators

4.4.2 OC12 LR/STM4 LH 1310 Port-Level Indicators

4.4.3 OC12 LR/STM4 LH 1310 Card Specifications

4.5 OC12 LR/STM4 LH 1550 Card

4.5.1 OC12 LR/STM4 LH 1550 Card-Level Indicators

4.5.2 OC12 LR/STM4 LH 1550 Port-Level Indicators

4.5.3 OC12 LR/STM4 LH 1550 Card Specifications

4.6 OC12 IR/STM4 SH 1310-4 Card

4.6.1 OC12 IR/STM4 SH 1310-4 Slots and Connectors

4.6.2 OC12 IR/STM4 SH 1310-4 Faceplate and Block Diagram

4.6.3 OC12 IR/STM4 SH 1310-4 Card-Level Indicators

4.6.4 OC12 IR/STM4 SH 1310-4 Port-Level Indicators

4.6.5 OC12 IR/STM4 SH 1310-4 Specifications

4.7 OC48 IR 1310 Card

4.7.1 OC48 IR 1310 Card-Level Indicators

4.7.2 OC48 IR 1310 Port-Level Indicators

4.7.3 OC48 IR 1310 Card Specifications

4.8 OC48 LR 1550 Card

4.8.1 OC48 LR 1550 Card-Level Indicators

4.8.2 OC48 LR 1550 Port-Level Indicators

4.8.3 OC48 LR 1550 Card Specifications

4.9 OC48 IR/STM16 SH AS 1310 Card

4.9.1 OC48 IR/STM16 SH AS 1310 Card-Level Indicators

4.9.2 OC48 IR/STM16 SH AS 1310 Port-Level Indicators

4.9.3 OC48 IR/STM16 SH AS 1310 Compatibility

4.9.4 OC48 IR/STM16 SH AS 1310 Card Specifications

4.10 OC48 LR/STM16 LH AS 1550 Card

4.10.1 OC48 LR/STM16 LH AS 1550 Card-Level Indicators

4.10.2 OC48 LR/STM16 LH AS 1550 Port-Level Indicators

4.10.3 OC48 LR/STM16 LH AS 1550 Compatibility

4.10.4 OC48 LR/STM16 LH AS 1550 Card Specifications

4.11 OC48 ELR/STM16 EH 100 GHz Cards

4.11.1 OC48 ELR 100 GHz Card-Level Indicators

4.11.2 OC48 ELR 100 GHz Port-Level Indicators

4.11.3 OC48 ELR 100 GHz Compatibility

4.11.4 OC48 ELR 100 GHz Card Specifications

4.12 OC48 ELR 200 GHz Cards

4.12.1 OC48 ELR 200 GHz Card-Level Indicators

4.12.2 OC48 ELR 200 GHz Port-Level Indicators

4.12.3 OC48 ELR 200 GHz Compatibility

4.12.4 OC48 ELR 200 GHz Card Specifications

4.13 OC192 LR/STM64 LH 1550 Card

4.13.1 OC192 LR/STM64 LH 1550 Card-Level Indicators

4.13.2 OC192 LR/STM64 LH 1550 Port-Level Indicators

4.13.3 OC192 LR/STM64 LH 1550 Compatibility

4.13.4 OC192 LR/STM64 LH 1550 Card Specifications


Optical Cards


This chapter describes Cisco ONS 15454 card features and functions. For installation and card turn-up procedures, see the Cisco ONS 15454 Procedure Guide.

Chapter topics include:

Card Overview

OC3 IR 4/STM1 SH 1310 Card

OC12 IR/STM4 SH 1310 Card

OC12 LR/STM4 LH 1310 Card

OC12 LR/STM4 LH 1550 Card

OC12 IR/STM4 SH 1310-4 Card

OC48 IR 1310 Card

OC48 LR 1550 Card

OC48 IR/STM16 SH AS 1310 Card

OC48 LR/STM16 LH AS 1550 Card

OC48 ELR/STM16 EH 100 GHz Cards

OC48 ELR 200 GHz Cards

OC192 LR/STM64 LH 1550 Card

4.1 Card Overview

The optical card overview section summarizes card functions, power consumption, temperature ranges, and compatibility.


Note Each card is marked with a symbol that corresponds to a slot (or slots) on the ONS 15454 shelf assembly. The cards are then installed into slots displaying the same symbols. See the "Card Slot Requirements" section on page 1-37 for a list of slots and symbols.


4.1.1 Optical Cards

Table 4-1 lists the Cisco ONS 15454 optical cards.

Table 4-1 Optical Cards for the ONS 15454 

Card
Port Description
For Additional Information...
OC3 IR 4 SH 1310

The OC3 IR 4 1310 card provides four intermediate or short-range OC-3 ports.

Note The OC3 IR 4 SH 1310 and OC3 IR 4/STM1 SH 1310 cards are functionally the same.

See the "OC3 IR 4/STM1 SH 1310 Card" section

OC12 IR 1310

The OC12 IR 1310 card provides one intermediate or short-range OC-12 port.

Note The OC12 IR 1310 and OC12/STM4 SH 1310 cards are functionally the same.

See the "OC12 IR/STM4 SH 1310 Card" section

OC12 LR 1310

The OC12 LR 1310 card provides one long-range OC-12 port and operates at 1310 nm.

Note The OC12 LR 1310 and OC12 LR/STM4 LH 1310 cards are functionally the same.

See the "OC12 LR/STM4 LH 1310 Card" section

OC12 LR 1550

The OC12 LR 1550 card provides one long-range OC-12 port and operates at 1550 nm.

Note The OC12 LR 1550 and OC12 LR/STM4 LH 1550 cards are functionally the same.

See the "OC12 LR/STM4 LH 1550 Card" section

OC3 IR 4/ STM1 SH 1310

The OC3 IR 4/STM1 SH 1310 card provides four intermediate or short-range OC-3 ports.

See the "OC3 IR 4/STM1 SH 1310 Card" section

OC12 IR/ STM4 SH 1310

The OC12 IR/STM4 SH 1310 card provides one intermediate or short-range OC-12 port.

See the "OC12 IR/STM4 SH 1310 Card" section

OC12 LR/ STM4 LH 1310

The OC12 LR/STM4 LH 1310 card provides one long-range OC-12 port and operates at 1310 nm.

See the "OC12 LR/STM4 LH 1310 Card" section

OC12 LR/ STM4 LH 1550

The OC12 LR/STM4 LH 1550 card provides one long-range OC-12 port and operates at 1550 nm.

See the "OC12 LR/STM4 LH 1550 Card" section

OC12 IR/STM4 SH 1310-4

The OC12 IR/STM4 SH 1310-4 card provides four intermediate or short-range OC-12/STM-4 ports.

See the "OC12 IR/STM4 SH 1310-4 Card" section

OC48 IR 1310

The OC48 IR 1310 card provides one intermediate-range OC-48 port and operates at 1310 nm. This card functions in slots 5, 6, 12, or 13 only.

See the "OC48 IR 1310 Card" section

OC48 LR 1550

The OC48 LR 1550 card provides one long-range OC-48 port and operates at 1550 nm. This card functions in slots 5, 6, 12, or 13 only.

See the "OC48 LR 1550 Card" section

OC48 IR/ STM16 SH AS 1310

The OC48 IR/STM16 SH AS 1310 card provides one intermediate-range OC-48 port and operates in any multispeed or high-speed card slot.

See the "OC48 IR/STM16 SH AS 1310 Card" section

OC48 LR/ STM16 LH AS 1550

The OC48 LR/STM16 LH AS 1550 card provides one long-range OC-48 port and operates in any multispeed or high-speed card slot.

See the "OC48 LR/STM16 LH AS 1550 Card" section

OC48 ELR/ STM16 EH 100 GHz

Thirty-seven distinct OC48 ITU 100 GHz dense wavelength division multiplexing (DWDM) cards provide the ONS 15454 DWDM channel plan.

See the "OC48 ELR/STM16 EH 100 GHz Cards" section

OC48 ELR 200 GHz

Eighteen distinct OC48 ITU 200GHz DWDM cards provide the ONS 15454 DWDM channel plan.

See the "OC48 ELR 200 GHz Cards" section

OC192 LR/ STM64 LH 1550

The OC192 LR/STM64 LH 1550 card provides one long-range OC-192 port and operates at 1550 nm.

See the "OC192 LR/STM64 LH 1550 Card" section


4.1.2 Card Power Requirements

Table 4-2 lists power requirements for individual cards.


Note Asterisks (*) next to card or fan tray names mean the power specification shown below is based on a calculation because an actual measurement was not available at the time of publication.


Table 4-2 Individual Card Power Requirements  

Card Name
Watts
Amps
BTU/Hr.

OC3 IR 4 SH 1310

19.20

0.40

65.56

OC12 IR 1310

10.90

0.23

37.22

OC12 LR 1310

10.90

0.23

37.22

OC12 LR 1550

9.28

0.19

31.68

OC3 IR 4/ STM1 SH 1310

19.20

0.40

65.56

OC12 IR/ STM4 SH 1310

10.90

0.23

37.22

OC12 LR/ STM4 LH 1310 *

12

0.25

41

OC12 LR/ STM4 LH 1550

9.28

0.19

31.68

OC12 IR/STM4 SH 1310-4 *

28

0.58

95.6

OC48 IR 1310

32.20

0.67

109.94

OC48 LR 1550

26.80

0.56

91.50

OC48 IR/ STM16 SH AS 1310

37.20

0.77

127.01

OC48 LR/ STM16 LH AS 1550

37.20

0.77

127.01

OC48 ELR/ STM16 EH 100 GHz

31.20

0.65

106.53

OC48 ELR 200 GHz

31.20

0.65

106.53

OC192 LR/ STM64 LH 1550

72.20

1.50

246.52


4.1.3 Card Temperature Ranges

Table 4-3 shows C-Temp and I-Temp compliant cards and their product names.


Note The I-Temp symbol is displayed on the faceplate of an I-Temp compliant card. A card without this symbol is C-Temp compliant.


Table 4-3 Optical Card Temperature Ranges and Product Names for the ONS 15454 

Card
C-Temp Product Name
(0 to +55 degrees Celsius)
I-Temp Product Name
(-40 to +65 degrees Celsius)
OC3 IR 4/STM1 SH 1310

15454-OC34IR1310

15454-OC34I13-T

OC12 IR/STM4 SH 1310

15454-OC121IR1310

15454-OC121I13-T

OC12 LR/STM4 LH 1310

15454-OC121LR1310

15454-OC121L13-T

OC12 LR/STM4 LH 1550

15454-OC121LR1550

15454-OC121L15-T

OC12 IR/STM4 SH 1310-4

15454-OC12IR1310-4

OC48 IR 1310

15454-OC481IR1310

OC48 LR 1550

15454-OC481LR1550

OC48 IR/STM16 SH AS 1310

15454-OC481IR1310A

OC48 LR/STM16 LH AS 1550

15454-OC481LR1550A

OC192 LR/STM64 LH 1550

15454-OC192LR1550

OC48 ELR/STM16 EH 100 GHz

15454-OC48E-1-28.7

15454-OC48E-1-30.3

15454-OC48E-1-31.1

15454-OC48E-1-31.9

15454-OC48E-1-32.6

15454-OC48E-1-33.4

15454-OC48E-1-34.2

15454-OC48E-1-35.0

15454-OC48E-1-35.8

15454-OC48E-1-36.6

15454-OC48E-1-38.1

15454-OC48E-1-38.9

15454-OC48E-1-39.7

15454-OC48E-1-40.5

15454-OC48E-1-41.3

15454-OC48E-1-42.1

15454-OC48E-1-42.9

15454-OC48E-1-43.7

15454-OC48E-1-44.5

15454-OC48E-1-46.1

15454-OC48E-1-46.9

15454-OC48E-1-47.7

15454-OC48E-1-48.5

15454-OC48E-1-49.3

15454-OC48E-1-50.1

OC48 ELR/STM16 EH 100 GHz (continued)

15454-OC48E-1-50.9

15454-OC48E-1-51.7

15454-OC48E-1-52.5

15454-OC48E-1-54.1

15454-OC48E-1-54.9

15454-OC48E-1-55.7

15454-OC48E-1-56.5

15454-OC48E-1-57.3

15454-OC48E-1-58.1

15454-OC48E-1-58.9

15454-OC48E-1-59.7

15454-OC48E-1-60.6

OC48 ELR/STM16 EH 200 GHz

15454-OC48E-30.33

15454-OC48E-31.90

15454-OC48E-33.47

15454-OC48E-35.04

15454-OC48E-36.61

15454-OC48E-38.19

15454-OC48E-39.77

15454-OC48E-31.35

15454-OC48E-42.94

15454-OC48E-47.72

15454-OC48E-49.32

15454-OC48E-50.92

15454-OC48E-52.52

15454-OC48E-54.13

15454-OC48E-55.75

15454-OC48E-57.36

15454-OC48E-58.98

15454-OC48E-60.61


4.2 OC3 IR 4/STM1 SH 1310 Card

The OC3 IR 4/STM1 SH 1310 card provides four intermediate or short range SONET/SDH OC-3 ports compliant with the International Telecommunication Union's G.707, G.957, and Telcordia's GR-253. Each port operates at 155.52 Mbps over a single-mode fiber span. The card supports VT and non-concatenated or concatenated payloads at the STS-1 or STS-3c signal levels. Figure 4-1 shows the OC3 IR 4/STM1 SH 1310 faceplate and a diagram of the card.


Note The OC3 IR 4 SH 1310 and OC3 IR 4/STM1 SH 1310 cards are functionally the same.


Figure 4-1 OC3 IR 4/STM1 SH 1310 faceplate and block diagram

You can install the OC3 IR 4/STM1 SH 1310 card in any multispeed or high-speed card slot. The card can be provisioned as part of a unidirectional path switched ring (UPSR) or in a linear add-drop multiplexer (ADM) configuration. Each port features a 1310 nm laser and contains a transmit and receive connector (labeled) on the card faceplate. The card uses SC connectors.

The OC3 IR 4/STM1 SH 1310 card supports 1+1 unidirectional or bidirectional protection switching. You can provision protection on a per port basis.

The OC3 IR 4/STM1 SH 1310 detects LOS, LOF, Loss of Pointer (LOP), line Alarm Indication Signal (AIS-L), and line Remote Defect Indication (RDI-L) conditions. See Alarm Troubleshooting in the Alarm Troubleshooting and Maintenance Guide for a description of these conditions. The card also counts section and line bit interleaved parity (BIP) errors.

4.2.1 OC3 IR 4/STM1 SH 1310 Card-Level Indicators

The OC3 IR 4/STM1 SH 1310 card has three card-level LED indicators.

Table 4-4 OC3 IR 4/STM1 SH 1310 Card-Level Indicators  

Card-Level Indicators
Description
Red FAIL LED

The red FAIL LED indicates that the card's processor is not ready. Replace the card if the red FAIL LED persists.

Green ACT LED

The green ACT LED indicates that the OC3 IR 4/STM1 SH 1310 card is carrying traffic or is traffic-ready.

Amber SF LED

The amber SF LED indicates a signal failure or condition such as LOS, LOF, AIS-L or high BER on one or more of the card's ports. The amber SF LED also illuminates when the transmit and receive fibers are incorrectly connected. When the fibers are properly connected, the light turns off.


4.2.2 OC3 IR 4/STM1 SH 1310 Port-Level Indicators

You can find the status of the four card ports using the LCD screen on the ONS 15454 fan-tray assembly. Use the LCD to view the status of any port or card slot; the screen displays the number and severity of alarms for a given port or slot.


Warning Invisible laser radiation may be emitted from the end of the unterminated fiber cable or connector. Do not stare into the beam or view directly with optical instruments. Viewing the laser output with certain optical instruments (for example, eye loupes, magnifiers, and microscopes) within a distance of 100 mm may pose an eye hazard. Use of controls or adjustments or performance of procedures other than those specified may result in hazardous radiation exposure.


4.2.3 OC3 IR 4/STM1 SH 1310 Card Specifications

Line

Bit Rate: 155.52 Mbps

Code: Scrambled NRZ

Fiber: 1310 nm single-mode

Loopback Modes: Terminal and Facility

Connector: SC

Compliance: Telcordia SONET, GR-GSY-00253, ITU-T G.707, ITU-T G.957

Transmitter

Max. Transmitter Output Power: -8 dBm

Min. Transmitter Output Power: -15 dBm

Center Wavelength: 1274 nm - 1356 nm

Nominal Wavelength: 1310 nm

Transmitter: Fabry Perot laser

Receiver

Max. Receiver Level: -8 dBm

Min. Receiver Level: -28 dBm

Receiver: InGaAs/InP photo detector

Link Loss Budget: 13 dB

Receiver Input Wavelength Range: 1274 nm - 1356 nm

Environmental

Operating Temperature:

C-Temp (15454-OC34IR1310): 0 to +55 degrees Celsius

I-Temp (15454-OC34I13-T): -40 to +65 degrees Celsius

Operating Humidity: 5 - 95%, non-condensing

Power Consumption: 19.20 W, 0.40 amps, 65.56 BTU/Hr.

Dimensions

Height: 12.650 in.

Width: 0.716 in.

Depth: 9.000 in.

Card Weight: 1.0 lbs, 0.4 kg

Compliance

ONS 15454 cards, when installed in a system, comply with these standards: Safety: UL 1950, CSA C22.2 No. 950, EN 60950, IEC 60950

Eye Safety Compliance: Class I

4.3 OC12 IR/STM4 SH 1310 Card

The OC12 IR/STM4 SH 1310 card provides one intermediate or short range SONET/SDH OC-12 port compliant with the International Telecommunication Union's G.707, G.957, and Telcordia's GR-253. The port operates at 622.08 Mbps over a single-mode fiber span. The card supports VT and non-concatenated or concatenated payloads at STS-1, STS-3c, STS-6c or STS-12c signal levels. Figure 4-2 shows the OC12 IR/STM4 SH 1310 faceplate and a block diagram of the card.


Note The OC12 IR 1310 and OC12/STM4 SH 1310 cards are functionally the same.


Figure 4-2 OC12 IR/STM4 SH 1310 faceplate and block diagram

You can install the OC12 IR/STM4 SH 1310 card in any multispeed or high-speed card slot and provision the card as a drop card or span card in a two-fiber BLSR, UPSR, or in ADM (linear) configurations.

The OC12 IR/STM4 SH 1310 port features a 1310 nm laser and contains a transmit and receive connector (labeled) on the card faceplate. The OC12 IR/STM4 SH 1310 uses SC optical connections and supports 1+1 unidirectional and bidirectional protection.

The OC12 IR/STM4 SH 1310 detects LOS, LOF, LOP, AIS-L, and RDI-L conditions. See the Cisco ONS 15454 Troubleshooting Guide for a description of these conditions. The card counts section and line BIT errors.

4.3.1 OC12 IR/STM4 SH 1310 Card-Level Indicators

The OC12 IR/STM4 SH 1310 card has three card-level LED indicators.

Table 4-5 OC12 IR/STM4 SH 1310 Card-Level Indicators  

Card-Level Indicators
Description
Red FAIL LED

The red FAIL LED indicates that the card's processor is not ready. Replace the card if the red FAIL LED persists.

Green ACT LED

The green ACT LED indicates that the OC12 IR/STM4 SH 1310 card is operational and is carrying traffic or is traffic-ready.

Amber SF LED

The amber SF LED indicates a signal failure or condition such as LOS, LOF, AIS-L or high BERs on the card's port. The amber SF LED also illuminates when the transmit and receive fibers are incorrectly connected. When the fibers are properly connected, the light turns off.


4.3.2 OC12 IR/STM4 SH 1310 Port-Level Indicators

You can find the status of the OC-12 card port using the LCD screen on the ONS 15454 fan-tray assembly. Use the LCD to view the status of any port or card slot; the screen displays the number and severity of alarms for a given port or slot.


Warning Invisible laser radiation may be emitted from the end of the unterminated fiber cable or connector. Do not stare into the beam or view directly with optical instruments. Viewing the laser output with certain optical instruments (for example, eye loupes, magnifiers, and microscopes) within a distance of 100 mm may pose an eye hazard. Use of controls or adjustments or performance of procedures other than those specified may result in hazardous radiation exposure.


4.3.3 OC12 IR/STM4 SH 1310 Card Specifications

Line

Bit Rate: 622.08 Mbps

Code: Scrambled NRZ

Fiber: 1310 nm single-mode

Loopback Modes: Terminal and Facility

Connectors: SC

Compliance: Telcordia SONET, GR-GSY-00253, ITU-T G.707, ITU-T G.957

Transmitter

Max. Transmitter Output Power: -8 dBm

Min. Transmitter Output Power: -15 dBm

Center Wavelength: 1274 nm - 1356 nm

Nominal Wavelength: 1310 nm

Transmitter: Fabry Perot laser

Receiver

Max. Receiver Level: -8 dBm

Min. Receiver Level: -28 dBm

Receiver: InGa As/InP photo detector

Link Loss Budget: 13 dB

Receiver Input Wavelength Range: 1274 nm - 1356 nm

Environmental

Operating Temperature:

C-Temp (15454-OC121IR1310): 0 to +55 degrees Celsius

I-Temp (15454-OC121I13-T): -40 to +65 degrees Celsius

Operating Humidity: 5 - 95%, non-condensing

Power Consumption: 10.90 W, 0.23 amps, 37.22 BTU/Hr.

Dimensions

Height: 12.650 in.

Width: 0.716 in.

Depth: 9.000 in.

Card Weight: 1.4 lbs, 0.6 kg

Compliance

ONS 15454 cards, when installed in a system, comply with these standards: Safety: UL 1950, CSA C22.2 No. 950, EN 60950, IEC 60950

Eye Safety Compliance: Class I

4.4 OC12 LR/STM4 LH 1310 Card

The OC12 LR/STM4 LH 1310 card provides one long-range, ITU-T G.707, ITU-T G.957, and Telcordia-compliant, GR-253 SONET OC-12 port per card. The port operates at 622.08 Mbps over a single-mode fiber span. The card supports VT and non-concatenated or concatenated payloads at STS-1, STS-3c, STS-6c or STS-12c signal levels. Figure 4-3 shows the OC12 LR/STM4 LH 1310 faceplate and a block diagram of the card.


Note The OC12 LR 1310 and OC12 LR/STM4 LH 1310 cards are functionally the same.


Figure 4-3 OC12 LR/STM4 LH 1310 faceplate and block diagram

You can install the OC12 LR/STM4 LH 1310 card in any multispeed or high-speed card slot and provision the card as a drop card or span card in a two-fiber BLSR (Bidirectional line switched ring), UPSR, or ADM (linear) configuration.

The OC12 LR/STM4 LH 1310 card port features a 1310 nm laser and contains a transmit and receive connector (labeled) on the card faceplate. The card uses SC optical connections supporting 1+1 unidirectional and bidirectional protection.

The OC12 LR/STM4 LH 1310 detects LOS, LOF, LOP, AIS-L, and RDI-L conditions. The card also counts section and line BIT errors.

4.4.1 OC12 LR/STM4 LH 1310 Card-Level Indicators

The OC12 LR/STM4 LH 1310 card has three card-level LED indicators.

Table 4-6 OC12 LR/STM4 LH 1310 Card-Level Indicators  

Card-Level Indicators
Description
Red FAIL LED

The red FAIL LED indicates that the card's processor is not ready. Replace the card if the red FAIL LED persists.

Green ACT LED

The green ACT LED indicates that the OC12 LR/STM4 LH 1310 card is operational and is carrying traffic or is traffic-ready.

Amber SF LED

The amber SF LED indicates a signal failure or condition such as LOS, LOF, AIS-L or high BERs on the card's port. The amber SF LED also illuminates when the transmit and receive fibers are incorrectly connected. When the fibers are properly connected, the light turns off.


4.4.2 OC12 LR/STM4 LH 1310 Port-Level Indicators

You can find the status of the OC12 LR/STM4 LH 1310 card port using the LCD screen on the ONS 15454 fan-tray assembly. Use the LCD to quickly view the status of any port or card slot; the screen displays the number and severity of alarms for a given port or slot.


Warning Invisible laser radiation may be emitted from the end of the unterminated fiber cable or connector. Do not stare into the beam or view directly with optical instruments. Viewing the laser output with certain optical instruments (for example, eye loupes, magnifiers, and microscopes) within a distance of 100 mm may pose an eye hazard. Use of controls or adjustments or performance of procedures other than those specified may result in hazardous radiation exposure.


4.4.3 OC12 LR/STM4 LH 1310 Card Specifications

Line

Bit Rate: 622.08 Mbps

Code: Scrambled NRZ

Fiber: 1310 nm single-mode

Loopback Modes: Terminal and Facility

Connectors: SC

Compliance: Telcordia SONET, GR-253-CORE, ITU-T G.707, ITU-T G.957

Transmitter

Max. Transmitter Output Power: +2 dBm

Min. Transmitter Output Power: -3 dBm

Center Wavelength: 1280 nm - 1335 nm

Nominal Wavelength: 1310 nm

Transmitter: Distributed feedback laser

Receiver

Max. Receiver Level: -8 dBm

Min. Receiver Level: -28 dBm

Receiver: InGaAs/InP photo detector

Link Loss Budget: 25 dB

Receiver Input Wavelength Range: 1280 nm - 1335 nm

Environmental

Operating Temperature:

C-Temp (15454-OC121LR1310): 0 to +55 degrees Celsius

I-Temp (15454-OC121L13-T): -40 to +65 degrees Celsius

Operating Humidity: 5 - 95%, non-condensing

Power Consumption: 9.28 W, 0.25 amps, 41BTU/Hr.

Dimensions

Height: 12.650 in.

Width: 0.716 in.

Depth: 9.000 in.

Card Weight: 1.4 lbs, 0.6 kg

Compliance

ONS 15454 cards, when installed in a system, comply with these standards: Safety: UL 1950, CSA C22.2 No. 950, EN 60950, IEC 60950

Eye Safety Compliance: Class I

4.5 OC12 LR/STM4 LH 1550 Card

The OC12 LR/STM4 LH 1550 card provides one long-range SONET/SDH OC-12 port compliant with the International Telecommunication Union's G.707, G.957, and Telcordia's GR-253. The port operates at 622.08 Mbps over a single-mode fiber span. The card supports VT and non-concatenated, or concatenated payloads at STS-1, STS-3c, STS-6c, or STS-12c signal levels. Figure 4-4 shows the OC12 LR/STM4 LH 1550 faceplate and a block diagram of the card.


Note The OC12 LR 1550 and OC12 LR/STM4 LH 1550 cards are functionally the same.


Figure 4-4 OC12 LR/STM4 LH 1550 faceplate and block diagram

You can install the OC12 LR/STM4 LH 1550 card in any multispeed card slot. The OC12 LR/STM4 LH 1550 can be provisioned as part of a two-fiber BLSR, UPSR or linear ADM.

The OC12 LR/STM4 LH 1550 uses long-reach optics centered at 1550 nm and contains a transmit and receive connector (labeled) on the card faceplate. The OC12 LR/STM4 LH 1550 uses SC optical connections and supports 1+1 bidirectional or unidirectional protection switching.

The OC12 LR/STM4 LH 1550 detects LOS, LOF, LOP, AIS-L, and RDI-L conditions. The card also counts section and line BIT errors.

4.5.1 OC12 LR/STM4 LH 1550 Card-Level Indicators

The OC12 LR/STM4 LH 1550 card has three card-level LED indicators.

Table 4-7 OC12 LR/STM4 LH 1550 Card-Level Indicators  

Card-Level Indicators
Description
Red FAIL LED

The red FAIL LED indicates that the card's processor is not ready. Replace the card if the red FAIL LED persists.

Green ACT LED

The green ACT LED indicates that the OC12 LR/STM4 LH 1550 card is operational and ready to carry traffic.

Amber SF LED

The amber SF LED indicates a signal failure or condition such as LOS, LOF, AIS-L or high BERs on the card's port. The amber SF LED also illuminates when the transmit and receive fibers are incorrectly connected. When the fibers are properly connected, the light turns off.


4.5.2 OC12 LR/STM4 LH 1550 Port-Level Indicators

You can find the status of the OC12 LR/STM4 LH 1550 card port using the LCD screen on the ONS 15454 fan-tray assembly. Use the LCD to view the status of any port or card slot; the screen displays the number and severity of alarms for a given port or slot.


Warning Invisible laser radiation may be emitted from the end of the unterminated fiber cable or connector. Do not stare into the beam or view directly with optical instruments. Viewing the laser output with certain optical instruments (for example, eye loupes, magnifiers, and microscopes) within a distance of 100 mm may pose an eye hazard. Use of controls or adjustments or performance of procedures other than those specified may result in hazardous radiation exposure.


4.5.3 OC12 LR/STM4 LH 1550 Card Specifications

Line

Bit Rate: 622.08 Mbps

Code: Scrambled NRZ

Fiber: 1550 nm single-mode

Loopback Modes: Terminal and Facility

Connectors: SC

Compliance: Telcordia SONET, GR-253-CORE, ITU-T G.707, ITU-T G.957

Transmitter

Max. Transmitter Output Power: +2 dBm

Min. Transmitter Output Power: -3 dBm

Center Wavelength: 1480 nm - 1580 nm

Nominal Wavelength: 1550 nm

Transmitter: Distributed feedback laser

Receiver

Max. Receiver Level: -8 dBm

Min. Receiver Level: -28 dBm

Receiver: InGaAs/InP photo detector

Link Loss Budget: 25 dB

Receiver Input Wavelength Range: 1480 nm - 1580 nm

Environmental

Operating Temperature:

C-Temp (15454-OC121LR1550): 0 to +55 degrees Celsius

I-Temp (15454-OC121L15-T): -40 to +65 degrees Celsius

Operating Humidity: 5 - 95%, non-condensing

Power Consumption: 9.28 W, 0.19 amps, 31.68 BTU/Hr.

Dimensions

Height: 12.650 in.

Width: 0.716 in.

Depth: 9.000 in.

Card Weight: 1.4 lbs, 0.6 kg

Compliance

ONS 15454 cards, when installed in a system, comply with these standards: Safety: UL 1950, CSA C22.2 No. 950, EN 60950, IEC 60950

Eye Safety Compliance: Class I

4.6 OC12 IR/STM4 SH 1310-4 Card

The OC12 IR/STM4 SH 1310-4 card provides four intermediate or short range SONET/SDH OC-12/STM-4 ports compliant with the International Telecommunication Union's G.707, G.957, and Telcordia's GR-253. Each port operates at 622.08 Mbps over a single-mode fiber span. The card supports VT and non-concatenated or concatenated payloads at the STS-1, STS-3c, STS-6c, or STS-12c signal levels.

The OC12 IR/STM4 SH 1310-4 card supports 1+1 unidirectional or bidirectional protection switching. You can provision protection on a per port basis.

The OC12 IR/STM4 SH 1310-4 detects LOS, LOF, Loss of Pointer (LOP), line Alarm Indication Signal (AIS-L), and line Remote Defect Indication (RDI-L) conditions. The card also counts section and line bit interleaved parity (BIP) errors.


Note If you ever expect to upgrade an OC-12/STM-4 ring to a higher bit rate, you should not put an OC12 IR/STM4 SH 1310-4 in that ring. The four-port card is not upgradable to a single-port card. The reason is that four different spans, possibly going to four different nodes, cannot be merged to a single span.


4.6.1 OC12 IR/STM4 SH 1310-4 Slots and Connectors

You can install the OC12 IR/STM4 SH 1310-4 card in any multispeed card slot. The card can be provisioned as part of a unidirectional path switched ring (UPSR) or in a linear add-drop multiplexer (ADM) configuration. Each port features a 1310 nm laser and contains a transmit and receive connector (labeled) on the card faceplate. The card uses SC connectors.

4.6.2 OC12 IR/STM4 SH 1310-4 Faceplate and Block Diagram

Figure 4-1 shows the OC12 IR/STM4 SH 1310-4 faceplate and a diagram of the card.

Figure 4-5 OC12 IR/STM4 SH 1310-4 faceplate and block diagram

4.6.3 OC12 IR/STM4 SH 1310-4 Card-Level Indicators

The OC12 IR/STM4 SH 1310-4 card has three card-level LED indicators.

Table 4-8 OC12 IR/STM4 SH 1310-4 Card-Level Indicators 

Card-Level Indicators
Description
Red FAIL LED

The red FAIL LED indicates that the card's processor is not ready. Replace the card if the red FAIL LED persists.

Green ACT LED

The green ACT LED indicates that the OC12 IR/STM4 SH 1310-4 card is carrying traffic or is traffic-ready.

Amber SF LED

The amber SF LED indicates a signal failure or condition such as LOS, LOF, AIS-L or high BER on one or more of the card's ports. The amber SF LED also illuminates when the transmit and receive fibers are incorrectly connected. When the fibers are properly connected, the light turns off.


4.6.4 OC12 IR/STM4 SH 1310-4 Port-Level Indicators

You can find the status of the four card ports using the LCD screen on the ONS 15454 fan-tray assembly. Use the LCD to view the status of any port or card slot; the screen displays the number and severity of alarms for a given port or slot.


Warning Invisible laser radiation may be emitted from the end of the unterminated fiber cable or connector. Do not stare into the beam or view directly with optical instruments. Viewing the laser output with certain optical instruments (for example, eye loupes, magnifiers, and microscopes) within a distance of 100 mm may pose an eye hazard. Use of controls or adjustments or performance of procedures other than those specified may result in hazardous radiation exposure.


4.6.5 OC12 IR/STM4 SH 1310-4 Specifications

Line

Bit Rate: 622.08 Mbps

Code: Scrambled NRZ

Fiber: 1310 nm single-mode

Loopback Modes: Terminal and Facility

Connector: SC

Compliance: Telcordia SONET, GR-GSY-00253, ITU-T G.707, ITU-T G.957

Transmitter

Max. Transmitter Output Power: -8 dBm

Min. Transmitter Output Power: -15 dBm

Center Wavelength: 1274 nm - 1356 nm

Nominal Wavelength: 1310 nm

Transmitter: Fabry Perot laser

Receiver

Max. Receiver Level: -8 dBm

Min. Receiver Level: -30 dBm

Receiver: InGaAs/InP photo detector

Link Loss Budget: 15 dB

Receiver Input Wavelength Range: 1274 nm - 1356 nm

Operating Temperature

C-Temp: 0 to +55 degrees Celsius

Operating Humidity

5 - 95%, non-condensing

Power Consumption

28 W, 0.58 amps, 100 BTU/Hr.

Dimensions

Height: 12.650 in.

Width: 0.716 in.

Depth: 9.000 in.

Card Weight: 1.0 lbs, 0.4 kg

Compliance

ONS 15454 cards, when installed in a system, comply with these standards: Safety: UL 1950, CSA C22.2 No. 950, EN 60950, IEC 60950

Eye Safety Compliance: Class I


Note Minimum Transmit Power, Minimum Receive Power, and Link Loss Budget may exceed standard specifications.


4.7 OC48 IR 1310 Card

The OC48 IR 1310 card provides one intermediate-range, Telcordia-compliant, GR-253 SONET OC-48 port per card. Each port operates at 2.49 Gbps over a single-mode fiber span. The card supports VT and non-concatenated, or concatenated payloads at STS-1, STS-3c, STS-6c, STS-12c, or STS-48c signal levels. Figure 4-6 shows the OC48 IR 1310 faceplate and a block diagram of the card.

Figure 4-6 OC48 IR 1310 faceplate and block diagram

You can install the OC48 IR 1310 card in any high-speed card slot and provision the card as a drop or span card in a two-fiber or four-fiber BLSR, UPSR, or in an ADM (linear) configuration.

The OC-48 port features a 1310 nm laser and contains a transmit and receive connector (labeled) on the card faceplate. The OC48 IR 1310 uses SC connectors. The card supports 1+1 unidirectional and bidirectional protection switching.

The OC48 IR 1310 detects LOS, LOF, LOP, AIS-L, and RDI-L conditions. The card also counts section and line BIT errors.

4.7.1 OC48 IR 1310 Card-Level Indicators

The OC48 IR 1310 card has three card-level LED indicators.

Table 4-9 OC48 IR 1310 Card-Level Indicators  

Card-Level Indicators
Description
Red FAIL LED

The red FAIL LED indicates that the card's processor is not ready. Replace the card if the red FAIL LED persists.

Green ACT LED

The green ACT LED indicates that the OC48 IR 1310 card is carrying traffic or is traffic-ready.

Amber SF LED

The amber SF LED indicates a signal failure or condition such as LOS, LOF, AIS-L or high BERs on the card's port. The amber SF LED also illuminates when the transmit and receive fibers are incorrectly connected. When the fibers are properly connected, the light turns off.


4.7.2 OC48 IR 1310 Port-Level Indicators

You can find the status of the OC48 IR 1310 card port using the LCD screen on the ONS 15454 fan-tray assembly. Use the LCD to view the status of any port or card slot; the screen displays the number and severity of alarms for a given port or slot.


Warning Invisible laser radiation may be emitted from the end of the unterminated fiber cable or connector. Do not stare into the beam or view directly with optical instruments. Viewing the laser output with certain optical instruments (for example, eye loupes, magnifiers, and microscopes) within a distance of 100 mm may pose an eye hazard. Use of controls or adjustments or performance of procedures other than those specified may result in hazardous radiation exposure.


4.7.3 OC48 IR 1310 Card Specifications

Line

Bit Rate: 2.49 Gbps

Code: Scrambled NRZ

Fiber: 1310 nm single-mode

Loopback Modes: Terminal and Facility

Connectors: SC

Compliance: Telcordia SONET, GR-GSY-00253

Transmitter

Max. Transmitter Output Power: 0 dBm

Min. Transmitter Output Power: -5 dBm

Center Wavelength: 1280 nm - 1350 nm

Nominal Wavelength: 1310 nm

Transmitter: Uncooled direct modulated DFB

Receiver

Max. Receiver Level: 0 dBm

Min. Receiver Level: -18 dBm

Receiver: InGaAs InP photo detector

Link Loss Budget: 13 dB min.

Receiver Input Wavelength Range: 1280 nm - 1350 nm

Environmental

Operating Temperature:

C-Temp (15454-OC481IR1310): 0 to +55 degrees Celsius

Operating Humidity: 5 - 95%, non-condensing

Power Consumption: 32.20 W, 0.67 amps, 109.94 BTU/Hr.

Dimensions

Height: 12.650 in.

Width: 0.716 in.

Depth: 9.000 in.

Card Weight: 1.8 lbs, 0.8 kg

Compliance

ONS 15454 cards, when installed in a system, comply with these standards: Safety: UL 1950, CSA C22.2 No. 950, EN 60950, IEC 60950

Eye Safety Compliance: Class I

4.8 OC48 LR 1550 Card

The OC48 LR 1550 card provides one long-range, Telcordia-compliant, GR-253 SONET OC-48 port per card. Each port operates at 2.49 Gbps over a single-mode fiber span. The card supports VT, non-concatenated or concatenated payloads at STS-1, STS-3c, STS-6c STS-12c or STS-48c signal levels. Figure 4-7 shows the OC48 LR 1550 faceplate and a block diagram of the card.

Figure 4-7 OC48 LR 1550 faceplate and block diagram

You can install OC48 LR 1550 cards in any high-speed slot on the ONS 15454 and provision the card as a drop or span card in a two-fiber or four-fiber BLSR, UPSR, or in an ADM (linear) configuration.

The OC48 LR 1550 port features a 1550 nm laser and contains a transmit and receive connector (labeled) on the card faceplate. The card uses SC connectors, and it supports 1+1 unidirectional and bidirectional protection switching.

The OC48 LR 1550 detects LOS, LOF, LOP, AIS-L, and RDI-L conditions. The card also counts section and line BIT errors.

4.8.1 OC48 LR 1550 Card-Level Indicators

The OC48 LR 1550 card has three card-level LED indicators.

Table 4-10 OC48 LR 1550 Card-Level Indicators  

Card-Level Indicators
Description
Red FAIL LED

The red FAIL LED indicates that the card's processor is not ready. Replace the card if the red FAIL LED persists.

Green ACT LED

The green ACT LED indicates that the OC48 LR 1550 card is carrying traffic or is traffic-ready.

Amber SF LED

The amber SF LED indicates a signal failure or condition such as LOS, LOF or high BERs on the card's port. The amber SF LED also illuminates when the transmit and receive fibers are incorrectly connected. When the fibers are properly connected, the light turns off.


4.8.2 OC48 LR 1550 Port-Level Indicators

You can find the status of the OC48 LR 1550 card port using the LCD screen on the ONS 15454 fan-tray assembly. Use the LCD to view the status of any port or card slot; the screen displays the number and severity of alarms for a given port or slot.


Warning Invisible laser radiation may be emitted from the end of the unterminated fiber cable or connector. Do not stare into the beam or view directly with optical instruments. Viewing the laser output with certain optical instruments (for example, eye loupes, magnifiers, and microscopes) within a distance of 100 mm may pose an eye hazard. Use of controls or adjustments or performance of procedures other than those specified may result in hazardous radiation exposure.


4.8.3 OC48 LR 1550 Card Specifications

Line

Bit Rate: 2.49 Gbps

Code: Scrambled NRZ

Fiber: 1550 nm single-mode

Loopback Modes: Terminal and Facility

Connectors: SC

Compliance: Telcordia SONET, GR-GSY-00253

Transmitter

Max. Transmitter Output Power: +3 dBm

Min. Transmitter Output Power: -2 dBm

Center Wavelength: 1520 nm - 1580 nm

Nominal Wavelength: 1550 nm

Transmitter: Distributed feedback laser

Receiver

Max. Receiver Level: -8 dBm

Min. Receiver Level: -28 dBm

Receiver: InGaAs APD photo detector

Link Loss Budget: 26 dB min., with 1 dB dispersion penalty

Receiver Input Wavelength Range: 1520 nm - 1580 nm

Environmental

Operating Temperature:

C-Temp (15454-OC481LR1550): 0 to +55 degrees Celsius

Operating Humidity: 5 - 95%, non-condensing

Power Consumption: 26.80 W, 0.56 amps, 91.50 BTU/Hr.

Dimensions

Height:12.650 in.

Width: 0.716 in.

Depth: 9.000 in.

Card Weight: 1.8 lbs, 0.8 kg

Compliance

ONS 15454 cards, when installed in a system, comply with these standards: Safety: UL 1950, CSA C22.2 No. 950, EN 60950, IEC 60950

Eye Safety Compliance: Class I

4.9 OC48 IR/STM16 SH AS 1310 Card

The OC48 IR/STM16 SH AS 1310 card provides one intermediate-range SONET/SDH OC-48 port compliant with the International Telecommunication Union's G.707, G.957, and Telcordia's GR-253. The port operates at 2.49 Gbps over a single-mode fiber span. The card supports VT and non-concatenated or concatenated payloads at STS-1, STS-3c, STS-6c, STS-12c, or STS-48c signal levels. Figure 4-8 shows the OC48 IR/STM16 SH AS 1310 faceplate and a block diagram of the card.

Figure 4-8 OC48 IR/STM16 SH AS 1310 faceplate and block diagram

You can install the OC48 IR/STM16 SH AS 1310 card in any multispeed or high-speed card slot on the ONS 15454 and provision the card as a drop or span card in a two-fiber or four-fiber BLSR, UPSR, or in an ADM (linear) configuration.

The OC-48 port features a 1310 nm laser and contains a transmit and receive connector (labeled) on the card faceplate. The OC48 IR/STM16 SH AS 1310 uses SC connectors. The card supports 1+1 unidirectional and bidirectional protection switching.

The OC48 IR/STM16 SH AS 1310 detects LOS, LOF, LOP, AIS-L, and RDI-L conditions. The card also counts section and line BIT errors.

4.9.1 OC48 IR/STM16 SH AS 1310 Card-Level Indicators

The OC48 IR/STM16 SH AS 1310 card has three card-level LED indicators.

Table 4-11 OC48 IR/STM16 SH AS 1310 Card-Level Indicators  

Card-Level Indicators
Description
Red FAIL LED

The red FAIL LED indicates that the card's processor is not ready. Replace the card if the red FAIL LED persists.

Green ACT LED

The green ACT LED indicates that the OC48 IR/STM16 SH AS 1310 card is carrying traffic or is traffic-ready.

Amber SF LED

The amber SF LED indicates a signal failure or condition such as LOS, LOF, AIS-L or high BERs on the card's port. The amber SF LED also illuminates when the transmit and receive fibers are incorrectly connected. When the fibers are properly connected, the light turns off.


4.9.2 OC48 IR/STM16 SH AS 1310 Port-Level Indicators

You can find the status of the OC48 IR/STM16 SH AS 1310 card port using the LCD screen on the ONS 15454 fan-tray assembly. Use the LCD to view the status of any port or card slot; the screen displays the number and severity of alarms for a given port or slot.


Warning Invisible laser radiation may be emitted from the end of the unterminated fiber cable or connector. Do not stare into the beam or view directly with optical instruments. Viewing the laser output with certain optical instruments (for example, eye loupes, magnifiers, and microscopes) within a distance of 100 mm may pose an eye hazard. Use of controls or adjustments or performance of procedures other than those specified may result in hazardous radiation exposure.


4.9.3 OC48 IR/STM16 SH AS 1310 Compatibility

Use the XC10G card, the TCC+ card, the new 15454-SA-ANSI shelf assembly, and Software R3.1 or higher to enable the OC48 IR/STM16 SH AS 1310 card. The OC48 IR/STM16 SH AS 1310 card uses the BTC backplane interface to provide recognition in both the high-speed and multispeed slots.

4.9.4 OC48 IR/STM16 SH AS 1310 Card Specifications

Line

Bit Rate: 2.49 Gbps

Code: Scrambled NRZ

Fiber: 1310 nm Single Mode

Loopback Modes: Terminal and Facility

Connectors: SC

Compliance: Telcordia SONET, GR-GSY-00253, ITU-T G.707, ITU-T G.957

Transmitter

Max. Transmitter Output Power: 0 dBm

Min. Transmitter Output Power: -5 dBm

Center Wavelength: 1280 nm - 1350 nm

Nominal Wavelength: 1310nm

Transmitter: Distributed feedback laser

Receiver

Max. Receiver Level: 0 dBm

Min. Receiver Level: -18 dBm

Receiver: InGaAs InP photo detector

Link Loss Budget: 13 dB min.

Receiver Input Wavelength Range: 1280 nm - 1350 nm

Environmental

Operating Temperature:

C-Temp (15454-OC481IR1310A): 0 to +55 degrees Celsius

Operating Humidity: 5 - 95%, non-condensing

Power Consumption: 37.20 W, 0.77 amps, 127.01 BTU/Hr.

Dimensions

Height: 12.650 in.

Width: 0.716 in.

Depth: 9.000 in.

Card Weight: 2.2 lbs, 0.9 kg

Compliance

ONS 15454 cards, when installed in a system, comply with these standards: Safety: UL 1950, CSA C22.2 No. 950, EN 60950, IEC 60950

Eye Safety Compliance: Class I

4.10 OC48 LR/STM16 LH AS 1550 Card

The OC48 LR/STM16 LH AS 1550 card provides one long-range SONET/SDH OC-48 port compliant with the International Telecommunication Union's G.707, G.957, and Telcordia's GR-253. Each port operates at 2.49 Gbps over a single-mode fiber span. The card supports VT and non-concatenated or concatenated payloads at STS-1, STS-3c, STS-6c, STS-12c, or STS-48c signal levels. Figure 4-9 shows the OC48 LR/STM16 LH AS 1550 faceplate and a block diagram of the card.

Figure 4-9 OC48 LR/STM16 LH AS 1550 faceplate and block diagram

You can install OC48 LR/STM16 LH AS 1550 cards in any multispeed or high-speed slot on the ONS 15454 and provision the card as a drop or span card in a two-fiber or four-fiber BLSR, UPSR, or in an ADM (linear) configuration.

The OC48 LR/STM16 LH AS 1550 port features a 1550 nm laser and contains a transmit and receive connector (labeled) on the card faceplate. The card uses SC connectors, and it supports 1+1 unidirectional and bidirectional protection switching.

The OC48 LR/STM16 LH AS 1550 detects LOS, LOF, LOP, AIS-L, and RDI-L conditions. The card also counts section and line BIT errors.

4.10.1 OC48 LR/STM16 LH AS 1550 Card-Level Indicators

The OC48 LR/STM16 LH AS 1550 card has three card-level LED indicators.

Table 4-12 OC48 LR/STM16 LH AS 1550 Card-Level Indicators  

Card-Level Indicators
Description
Red FAIL LED

The red FAIL LED indicates that the card's processor is not ready. Replace the card if the red FAIL LED persists.

Green ACT LED

The green ACT LED indicates that the OC48 LR/STM16 LH AS 1550 card is carrying traffic or is traffic-ready.

Amber SF LED

The amber SF LED indicates a signal failure or condition such as LOS, LOF or high BERs on the card's port. The amber SF LED also illuminates when the transmit and receive fibers are incorrectly connected. When the fibers are properly connected, the light turns off.


4.10.2 OC48 LR/STM16 LH AS 1550 Port-Level Indicators

You can find the status of the OC48 LR/STM16 LH AS 1550 card port using the LCD screen on the ONS 15454 fan-tray assembly. Use the LCD to view the status of any port or card slot; the screen displays the number and severity of alarms for a given port or slot.


Warning Invisible laser radiation may be emitted from the end of the unterminated fiber cable or connector. Do not stare into the beam or view directly with optical instruments. Viewing the laser output with certain optical instruments (for example, eye loupes, magnifiers, and microscopes) within a distance of 100 mm may pose an eye hazard. Use of controls or adjustments or performance of procedures other than those specified may result in hazardous radiation exposure.


4.10.3 OC48 LR/STM16 LH AS 1550 Compatibility

Use the XC10G card, the TCC+ card, the new 15454-SA-ANSI shelf assembly, and Software R3.1 or higher to enable the OC48 LR/STM16 LH AS 1550 card. The OC48 LR/STM16 LH AS 1550 card uses the BTC backplane interface to provide recognition in both the high-speed and multispeed slots.

4.10.4 OC48 LR/STM16 LH AS 1550 Card Specifications

Line

Bit Rate: 2.49 Gbps

Code: Scrambled NRZ

Fiber: 1550 nm Single Mode

Loopback Modes: Terminal and Facility

Connectors: SC

Compliance: Telcordia SONET, GR-GSY-00253, ITU-T G.707, ITU-T G.957

Transmitter

Max. Transmitter Output Power: +3 dBm

Min. Transmitter Output Power: -2 dBm

Center Wavelength: 1520 nm - 1580 nm

Nominal Wavelength: 1550 nm

Transmitter: Distributed feedback laser

Receiver

Max. Receiver Level: -8 dBm

Min. Receiver Level: -28 dBm

Receiver: InGaAs APD photo detector

Link Loss Budget: 26 dB min., with 1 dB dispersion penalty

Receiver Input Wavelength Range: 1520 nm - 1580 nm

Environmental

Operating Temperature:

C-Temp (15454-OC481LR1550A): 0 to +55 degrees Celsius

Operating Humidity: 5 - 95%, non-condensing

Power Consumption: 37.20 W, 0.77 amps, 127.01 BTU/Hr.

Dimensions

Height:12.650 in.

Width: 0.716 in.

Depth: 9.000 in.

Card Weight: 2.2 lbs, 0.9 kg

Compliance

ONS 15454 cards, when installed in a system, comply with these standards: Safety: UL 1950, CSA C22.2 No. 950, EN 60950, IEC 60950

Eye Safety Compliance: Class I

4.11 OC48 ELR/STM16 EH 100 GHz Cards

Thirty-seven distinct OC48 ITU 100GHz dense wavelength division multiplexing (DWDM) cards provide the ONS 15454 DWDM channel plan. Each OC-48 DWDM card has one SONET OC-48/SDH STM-16 port that complies with Telcordia, GR-253 SONET, and the International Telecommunication Union's ITU-T G.692, and ITU-T G.958.

The port operates at 2.49 Gbps over a single-mode fiber span. The card carries VT, concatenated, and non-concatenated payloads at STS-1, STS-3c, STS-6c, STS-12c, or STS-48c signal levels. Figure 4-10 shows the OC48 ELR/STM16 EH 100 GHz faceplate and a block diagram of the card.

Figure 4-10 OC48 ELR/STM16 EH 100 GHz faceplate and block diagram

Nineteen of the cards operate in the blue band with spacing of 100 GHz on the ITU grid standard G.692 and Telcordia GR-2918-CORE, issue 2 (1528.77 nm, 1530.33 nm, 1531.12 nm, 1531.90 nm, 1532.68 nm, 1533.47 nm, 1534.25 nm, 1535.04 nm, 1535.82 nm, 1536.61 nm, 1538.19 nm, 1538.98 nm, 1539.77 nm, 1540.56 nm, 1541.35 nm, 1542.14 nm, 1542.94 nm, 1543.73 nm, 1544.53 nm).

The other eighteen cards operate in the red band with spacing of 100 GHz on the ITU grid (1546.12 nm, 1546.92 nm, 1547.72 nm, 1548.51 nm,1549.32 nm, 1550.12 nm, 1550.92 nm, 1551.72 nm, 1552.52 nm, 1554.13 nm, 1554.94 nm, 1555.75 nm, 1556.55 nm, 1557.36 nm, 1558.17 nm, 1558.98 nm, 1559.79 nm, 1560.61 nm). These cards are also designed to interoperate with the Cisco ONS 15216 DWDM solution.

You can install the OC48 ELR/STM16 EH 100 GHz cards in any high-speed slot and provision the card as a drop or span card in a two-fiber or four-fiber BLSR, UPSR, or in an ADM (linear) configuration. Each OC48 ELR/STM16 EH 100 GHz card uses extended long reach optics operating individually within the ITU-T 100 GHz grid. The OC-48 DWDM cards are intended to be used in applications with long unregenerated spans of up to 200 km (with mid-span amplification). These transmission distances are achieved through the use of inexpensive optical amplifiers (flat gain amplifiers) such as Cisco ONS 15216 erbium-doped fiber amplifiers (EDFAs).

Maximum system reach in filterless applications is 26 dB without the use of optical amplifiers or regenerators. However, system reach also depends on the condition of the facilities, number of splices and connectors, and other performance-affecting factors. When used in combination with ONS 15216 100 GHz filters, the link budget is reduced by the insertion loss of the filters plus an additional 2dB power penalty. The OC-48 ELR DWDM cards wavelength stability is +/- 0.12 nm for the life of the product and over the full range of operating temperatures. Each interface contains a transmitter and receiver.

The OC-48 ELR cards detect loss of signal (LOS), loss of frame (LOF), loss of pointer (LOP), and line-layer alarm indication signal (AIS-L) conditions. The cards also count section and line BIT errors.

4.11.1 OC48 ELR 100 GHz Card-Level Indicators

The OC48 ELR/STM16 EH 100 GHz cards have three card-level LED indicators.

Table 4-13 OC48 ELR/STM16 EH 100 GHz Card-Level Indicators  

Card-Level Indicators
Description
Red FAIL LED

The red FAIL LED indicates that the card's processor is not ready. Replace the card if the red FAIL LED persists.

Green ACT LED

The green ACT LED indicates that the OC48 ELR card is carrying traffic or is traffic-ready.

Amber SF LED

The amber SF LED indicates a signal failure or condition such as LOS, LOF or high BERs on the card's port. The amber SF LED also illuminates when the transmit and receive fibers are incorrectly connected. When the fibers are properly connected, the light turns off.


4.11.2 OC48 ELR 100 GHz Port-Level Indicators

You can find the status of the OC48 ELR card ports using the LCD screen on the ONS 15454 fan-tray assembly. Use the LCD to quickly view the status of any port or card slot; the screen displays the number and severity of alarms for a given port or slot.


Warning Invisible laser radiation may be emitted from the end of the unterminated fiber cable or connector. Do not stare into the beam or view directly with optical instruments. Viewing the laser output with certain optical instruments (for example, eye loupes, magnifiers, and microscopes) within a distance of 100 mm may pose an eye hazard. Use of controls or adjustments or performance of procedures other than those specified may result in hazardous radiation exposure.


4.11.3 OC48 ELR 100 GHz Compatibility

The OC48 ELR/STM16 EH 100 GHz card requires a cross-connect (XC) card, cross-connect virtual tributary (XCVT) card, or an XC10G for proper operation.

4.11.4 OC48 ELR 100 GHz Card Specifications

Line

Bit Rate: 2.49 Gbps

Code: Scrambled NRZ

Fiber: 1550 nm single-mode

Loopback Modes: Terminal and Facility

Connectors: SC

Compliance: Telcordia SONET, GR-GSY-00253, ITU-T G.692, ITU-T G.958

Transmitter

Max. Transmitter Output Power: 0 dBm

Min. Transmitter Output Power: -2 dBm

Center Wavelength: ±.12 nm

Transmitter: Electro-absorption laser

Receiver

Max. Receiver Level: -9 dBm

Min. Receiver Level: -27 dBm at 1E-12 BER

Receiver: InGaAs APD photo detector

Link Loss Budget: 25 dB min. at BER=10E-12, (not including the power dispersion penalty)

Dispersion Penalty: 2dB for a dispersion of up to 5400 ps/nm

Receiver Input Wavelength Range: 1520 nm - 1580 nm

Environmental

Operating Temperature:

C-Temp: 0 to +55 degrees Celsius (For product names, see Card Temperature Ranges)

Operating Humidity: 5 - 95%, non-condensing

Power Consumption: 31.20 W, 0.65 amps, 106.53 BTU/Hr.

Dimensions

Height:12.650 in.

Width: 0.716 in.

Depth: 9.000 in.

Card Weight: 2.4 lbs, 1.1 kg

Compliance

ONS 15454 cards, when installed in a system, comply with these standards: Safety: UL 1950, CSA C22.2 No. 950, EN 60950, IEC 60950

Eye Safety Compliance: Class I

4.12 OC48 ELR 200 GHz Cards

Eighteen distinct OC48 ITU 200GHz dense wavelength division multiplexing (DWDM) cards provide the ONS 15454 DWDM channel plan. Each OC-48 DWDM card provides one Telcordia-compliant, GR-253 SONET OC-48 port. The port operates at 2.49 Gbps over a single-mode fiber span. The card carries VT, concatenated, and non-concatenated payloads at STS-1, STS-3c, STS-6c, STS-12c, or STS-48c signal levels. Figure 4-11 shows the OC48 ELR DWDM faceplate and a block diagram of the card.

Figure 4-11 OC48 ELR 200 GHz faceplate and block diagram

Nine of the cards operate in the blue band with spacing of 200 GHz on the ITU grid (1530.33 nm, 1531.90 nm, 1533.47 nm, 1535.04 nm, 1536.61 nm, 1538.19 nm, 1539.77 nm, 1541.35 nm, 1542.94 nm).

The other nine cards operate in the red band with spacing of 200 GHz on the ITU grid
(1547.72 nm, 1549.32 nm, 1550.92 nm, 1552.52 nm, 1554.13 nm, 1555.75 nm, 1557.36 nm, 1558.98 nm, 1560.61 nm). These cards are also designed to interoperate with the Cisco ONS 15216 DWDM solution.

You can install the OC48 ELR 200 GHz cards in any high-speed slot and provision the card as a drop or span card in a two-fiber or four-fiber BLSR, UPSR, or in an ADM (linear) configuration. Each OC48 ELR DWDM card uses extended long reach optics operating individually within the ITU-T 200 GHz grid. The OC48 DWDM cards are intended to be used in applications with long unregenerated spans of up to 200 km (with mid-span amplification). These transmission distances are achieved through the use of inexpensive optical amplifiers (flat gain amplifiers) such as erbium doped fiber amplifiers (EDFAs). Using co-located amplification, distances up to 200 km can be achieved for a single channel (160 km for 8 channels).

Maximum system reach in filterless applications is 24 dB or approximately 80 km without the use of optical amplifiers or regenerators. However, system reach also depends on the condition of the facilities, number of splices and connectors or other performance-affecting factors. The OC48 ELR DWDM cards feature wavelength stability of +/- 0.25 nm. Each interface contains a transmitter and receiver.

The OC48 ELR DWDM cards are the first in a family of cards meant to support extended long reach applications in conjunction with optical amplification. Using electro-absorption technology, the OC48 DWDM cards provide a solution at the lower-extended long reach distances.

The OC48 LR 1550 interface features a 1550 nm laser and contains a transmit and receive connector (labeled) on the card faceplate. The card uses SC connectors and supports 1+1 unidirectional and bidirectional protection switching.

The OC48 ELR cards detect LOS, LOF, LOP, AIS-L, and RDI-L conditions. The cards also count section and line BIT errors.

To enable APS, the OC48 ELR cards extract the K1 and K2 bytes from the SONET overhead. The DCC bytes are forwarded to the TCC+ card; the TCC+ terminates the DCC.

4.12.1 OC48 ELR 200 GHz Card-Level Indicators

The OC48 ELR cards have three card-level LED indicators.

Table 4-14 OC48 ELR 200 GHz Card-Level Indicators  

Card-Level Indicators
Description
Red FAIL LED

The red FAIL LED indicates that the card's processor is not ready. Replace the card if the red FAIL LED persists.

Green ACT LED

The green ACT LED indicates that the OC48 ELR card is carrying traffic or is traffic-ready.

Amber SF LED

The amber SF LED indicates a signal failure or condition such as LOS, LOF or high BERs on the card's port. The amber SF LED also illuminates when the transmit and receive fibers are incorrectly connected. When the fibers are properly connected, the light turns off.


4.12.2 OC48 ELR 200 GHz Port-Level Indicators

You can find the status of the OC48 ELR card ports using the LCD screen on the ONS 15454 fan-tray assembly. Use the LCD to quickly view the status of any port or card slot; the screen displays the number and severity of alarms for a given port or slot.


Warning Invisible laser radiation may be emitted from the end of the unterminated fiber cable or connector. Do not stare into the beam or view directly with optical instruments. Viewing the laser output with certain optical instruments (for example, eye loupes, magnifiers, and microscopes) within a distance of 100 mm may pose an eye hazard. Use of controls or adjustments or performance of procedures other than those specified may result in hazardous radiation exposure.


4.12.3 OC48 ELR 200 GHz Compatibility

The OC48 ELR/STM16 EH 200 GHz card requires an XC card, XCVT card, or XC10G card for proper operation.

4.12.4 OC48 ELR 200 GHz Card Specifications

Line

Bit Rate: 2.49 Gbps

Code: Scrambled NRZ

Fiber: 1550 nm single-mode

Loopback Modes: Terminal and Facility

Connectors: SC

Compliance: Telcordia SONET, GR-GSY-00253, ITU-T G692, ITU-T G958

Transmitter

Max. Transmitter Output Power: 0 dBm

Min. Transmitter Output Power: -2 dBm

Center Wavelength: ±.25 nm

Transmitter: Electro-absorption laser

Receiver

Max. Receiver Level: -8 dBm

Min. Receiver Level: -28 dBm

Receiver: InGaAs APD photo detector

Link Loss Budget: 26 dB min., with 1 dB dispersion penalty

Receiver Input Wavelength Range: 1520 nm - 1580 nm

Environmental

Operating Temperature:

C-Temp: 0 to +55 degrees Celsius

Operating Humidity: 5 - 95%, non-condensing

Power Consumption: 31.20 W, 0.65 amps, 106.53 BTU/Hr.

Dimensions

Height:12.650 in.

Width: 0.716 in.

Depth: 9.000 in.

Card Weight: 2.9 lbs, 1.3 kg

Compliance

ONS 15454 cards, when installed in a system, comply with these standards: Safety: UL 1950, CSA C22.2 No. 950, EN 60950, IEC 60950

Eye Safety Compliance: Class I

4.13 OC192 LR/STM64 LH 1550 Card

The OC192 LR/STM64 LH 1550 card provides one long-range SONET/SDH OC-192 port compliant with the International Telecommunication Union's G.707, G.957, and Telcordia's GR-1377 and GR-253. The card port operates at 9.96 Gbps over unamplified distances up to 80 km with different types of fiber such as C-SMF or dispersion compensated fiber limited by loss and/or dispersion. The card supports VT and non-concatenated or concatenated payloads.

Figure 4-12 shows the OC192 LR/STM64 LH 1550 faceplate and a block diagram of the card. Figure 4-13 shows an enlarged view of the faceplate warning.

Figure 4-12 OC192 LR/STM64 LH 1550 faceplate and block diagram

Figure 4-13 Enlarged section of the OC192 LR/STM64 LH 1550 faceplate


Caution You must use a 19 to 24 dB (20 recommended) fiber attenuator when connecting a fiber loopback to an OC192 LR/STM64 LH 1550 card. Never connect a direct fiber loopback. Using fiber loopbacks causes irreparable damage to the OC-192 card. A Tx to Rx connection that is not attenuated will damage the receiver.

You can install OC192 LR/STM64 LH 1550 cards in any high-speed slot on the ONS 15454 and provision the card as a drop or span card in a two-fiber or four-fiber BLSR, UPSR, or in an ADM (linear) configuration.

The OC-192 card port features a 1550 nm laser and contains a transmit and receive connector (labeled) on the card faceplate.


Warning On the OC-192 card, the laser is on when the card is booted and the safety key is in the on position (labeled 1). The port does not have to be in service for the laser to be on. The laser is off when the safety key is off (labeled 0).


The card uses a dual SC connector for optical cable termination. The card supports 1+1 unidirectional and bidirectional facility protection. It also supports 1:1 protection in four-fiber bidirectional line switched ring applications where both span switching and ring switching may occur.

The OC192 LR/STM64 LH 1550 card detects SF, LOS, or LOF conditions on the optical facility. The card also counts section and line BIT errors from B1 and B2 byte registers in the section and line overhead.

4.13.1 OC192 LR/STM64 LH 1550 Card-Level Indicators

The OC192 LR/STM64 LH 1550 card has three card-level LED indicators.

Table 4-15 OC192 LR/STM64 LH 1550 Card-Level Indicators  

Card-Level Indicators
Description
Red FAIL LED

The red FAIL LED indicates that the card's processor is not ready. Replace the card if the red FAIL LED persists.

ACT/STBY LED
Green (Active)
Yellow (Standby)

When the ACTV/STBY LED is green, the OC-192 card is operational and ready to carry traffic. When the ACTV/STBY LED is amber, the OC-192 card is operational and in standby (protect) mode.

Yellow SF LED

The amber SF LED indicates a signal failure or condition such as LOS, LOF or high BERs on the card's port. The amber SF LED also illuminates when the transmit and receive fibers are incorrectly connected. When the fibers are properly connected, the light turns off.


4.13.2 OC192 LR/STM64 LH 1550 Port-Level Indicators

You can find the status of the OC192 LR/STM64 LH 1550 card port using the LCD screen on the ONS 15454 fan-tray assembly. Use the LCD to view the status of the port or card slot; the screen displays the number and severity of alarms for a given port or slot.


Warning Invisible laser radiation may be emitted from the end of the unterminated fiber cable or connector. Do not stare into the beam or view directly with optical instruments. Viewing the laser output with certain optical instruments (for example, eye loupes, magnifiers, and microscopes) within a distance of 100 mm may pose an eye hazard. Use of controls or adjustments or performance of procedures other than those specified may result in hazardous radiation exposure.


4.13.3 OC192 LR/STM64 LH 1550 Compatibility

Use the XC10G card, the TCC+ card, the new 15454-SA-ANSI shelf assembly, and Software R3.1 or higher to enable the OC192 LR/STM64 LH 1550 card.

4.13.4 OC192 LR/STM64 LH 1550 Card Specifications

Line

Bit Rate: 9.96 Gbps

Code: Scrambled NRZ

Fiber: 1550 nm Single Mode

Loopback Modes: Terminal and Facility


Note You must use a 19 to 24 dB (20 recommended) fiber attenuator when connecting a fiber loopback to an OC192 LR/STM64 LH 1550 card. Never connect a direct fiber loopback.


Connectors: SC

Compliance: Telcordia SONET, GR-GSY-00253, ITU-T G.707, ITU-T G.957

Transmitter

Max. Transmitter Output Power: +10 dBm

Min. Transmitter Output Power: +7 dBm

Center Wavelength: 1530 nm - 1565 nm

Nominal Wavelength: 1550 nm

Transmitter: LN (Lithium Niobate) external modulator transmitter

Receiver

Max. Receiver Level: -10 dBm

Min. Receiver Level: -19 dBm

Receiver: APD/TIA

Link Loss Budget: 24 dB min., with no dispersion or 22 dB optical path loss at BER = 1- exp (-12) including dispersion

Receiver Input Wavelength Range: 1530 nm - 1565 nm

Environmental

Operating Temperature:

C-Temp (15454-OC192LR1550): 0 to +55 degrees Celsius

Operating Humidity: 5 - 95%, non-condensing

Power Consumption: 72.20 W, 1.50 amps, 246.52 BTU/Hr.

Dimensions

Height:12.650 in.

Width: 0.716 in.

Depth: 9.000 in.

Card Weight: 3.1 lbs, 1.3 kg

Compliance

ONS 15454 OC192/STM64 cards, when installed in a system, comply with these standards: Safety: UL 1950, CSA C22.2 No. 950, EN 60950, IEC 60950

Eye Safety Compliance: Class I (21 CFR 1040.10 and 1040.11) and Class 1M (IEC 60825-12001-01) laser products


hometocprevnextglossaryfeedbacksearchhelp

Posted: Fri Feb 22 14:49:59 PST 2008
All contents are Copyright © 1992--2008 Cisco Systems, Inc. All rights reserved.