cc/td/doc/product/ong/15400
hometocprevnextglossaryfeedbacksearchhelp
PDF

Table Of Contents

Cisco ONS 15454 and Cisco ONS 15327
Common TL1 Commands
Release 3.4

BLSR

Cross Connections

Environment Alarms and Controls

Equipment

Fault

Log

Performance

Ports

Security

SONET Line Protection

STS Paths

STS and VT Paths

Synchronization

System

Test Access

Testing

UCP

UPSR Switching


Quick Reference

Cisco ONS 15454 and Cisco ONS 15327
Common TL1 Commands
Release 3.4


This guide lists TL1 commands and autonomous messages by category. It includes basic descriptions and input and output formats supported by the Cisco ONS 15454 and the Cisco ONS 15327, Release 3.4. Refer to the Cisco ONS 15454 and Cisco ONS 15327 TL1 Command Guide, Release 3.4 for a complete description of TL1 commands.

TL1 commands conform to the following syntax:
a:b:c:d:e: ...z;
where:
"a" is the Command Code
"b" is the Target Identifier (TID)
"c" is the Access Identifier (AID) or the User Identifier (UID)
"d" is the Correlation Tag (CTAG)
"e: ...z;" are other positions required for various commands
The TID, AID, and CTAG route and control the TL1 command.
Other parameters provide additional information required to complete the action requested by the command.

1  BLSR

Table 1 BLSR 

DLT-BLSR:[<TID>]:<AID>:<CTAG>[:::];
Deletes the BLSR of the NE

ED-BLSR:[<TID>]:<AID>:<CTAG>:::[RINGID=<RINGID>,][NODEID=<NODEID>,]
[RVRTV=<RVRTV>,][RVTM=<RVTM>,][SRVRTV=<SRVRTV>,][SRVTM=<SRVTM>][:]
Edits the BLSR attributes

ENT-BLSR:[<TID>]:<AID>:<CTAG>:::[RINGID=<RINGID>,]NODEID=<NODEID>,
MODE=<MODE>,[RVRTV=<RVRTV>,][RVTM=<RVTM>,][SRVRTV=<SRVRTV>,]
[SRVTM=<SRVTM>,]EASTWORK=<EASTWORK>,WESTWORK=<WESTWORK>,
[EASTPROT=<EASTPROT>,][WESTPROT=<WESTPROT>];
Creates either a two-fiber or four-fiber BLSR

REPT EVT RING
Reports the occurrence of a non-alarmed event against a ring object for a BLSR

RTRV-BLSR:[<TID>]:[<AID>]:<CTAG>[::::];
Retrieves all of the BLSR information of the network element (NE)
Output format:

SID DATE TIME
M CTAG COMPLD
"[<AID>]::[RINGID=<RINGID>,][NODEID=<NODEID>,][MODE=<MODE>,]
[RVRTV=<RVRTV>,][RVTM=<RVTM>,][SRVRTV=<SRVRTV>,][SRVTM=<SRVTM>,]
[EASTWORK=<EASTWORK>,][WESTWORK=<WESTWORK>,][EASTPROT=<EASTPROT>,]
[WESTPROT=<WESTPROT>]"
;

RTRV-COND-RING:[<TID>]:[<AID>]:<CTAG>::[<TYPEREQ>][,,,];
Retrieves the current standing condition against a ring object for BLSR
Output format:

SID DATE TIME
M CTAG COMPLD
"<AID>:[<NTFCNCDE>],<TYPEREP>,[<SRVEFF>],,,,,[<DESC>]"
;


2  Cross Connections

Table 2 Cross Connections 

DLT-CRS-<STS_PATH>:[<TID>]:<FROM>,<TO>:<CTAG>[:::];
Deletes a cross-connection between STS paths

DLT-CRS-VT1:[<TID>]:<FROM>,<TO>:<CTAG>[:::];
Deletes the virtual tributary cross-connections

ED-CRS-<STS_PATH>:[<TID>]:<SRC>,<DST>:<CTAG>::::[<PST>],[<SST>];
Edits the state of an STS cross-connection

ED-CRS-VT1:[<TID>]:<SRC>,<DST>:<CTAG>::::[<PST>],[<SST>];
Edits VT cross-connections

ENT-CRS-<STS_PATH>:[<TID>]:<FROM>,<TO>:<CTAG>::[<CCT>]::[<PST>],[<SST>];
Creates an STS cross-connection with cross-connection types (CCT)

ENT-CRS-VT1:[<TID>]:<FROM>,<TO>:<CTAG>::[<CCT>]::[<PST>],[<SST>];
Creates a VT1 cross-connection

RTRV-CRS:[<TID>]:<AID>:<CTAG>:::[CRSTYPE=<CRSTYPE>][:];
Retrieves all the cross-connections based on the required CRSTYPE (STS, VT, or both)
Output format:

SID DATE TIME
M CTAG COMPLD
"<FROM>,<TO>:<CCT>,<MOD>::<PST>,[<SST>]"
;

RTRV-CRS-<STS_PATH>:[<TID>]:<AID>:<CTAG>[::::];
Retrieves any connections associated with the entered AID(s) or AID range
Output format:

SID DATE TIME
M CTAG COMPLD
"<FROM>,<TO>:<CCT>,<MOD>::<PST>,[<SST>]"
;

RTRV-CRS-VT1:[<TID>]:<AID>:<CTAG>[::::];
Retrieves the VT cross-connection information
Output format:

SID DATE TIME
M CTAG COMPLD
"<FROM>,<TO>:<CCT>::<PST>,[<SST>]"
;


3  Environment Alarms and Controls

Table 3 Environment Alarms and Controls 

OPR-ACO-ALL:[<TID>]::<CTAG>;
Instructs the NE to cut-off the office audible alarm indications without changing the local alarm indications

OPR-EXT-CONT:[<TID>]:<AID>:<CTAG>::[<CONTTYPE>],[<DURATION>];
Operates an external control and closes the external control contact

REPT ALM ENV
Reports a user-defined condition on an environmental alarm input

REPT EVT ENV
Reports a non-alarmed event against an environment alarm input

RLS-EXT-CONT:[<TID>]:<AID>:<CTAG>[::,];
Releases a forced contact state and returns the control of the contact to an automatic control state

RTRV-ALM-ENV:[<TID>]:<AID>:<CTAG>::[<NTFCNCDE>],[<ALMTYPE>];
Retrieves the environmental alarms
Output format:

SID DATE TIME
M CTAG COMPLD
"<AID>:<NTFCNCDE>,<ALMTYPE>,,,[<DESC>]"
;

RTRV-ATTR-CONT:[<TID>]:<AID>:<CTAG>[::<CONTTYPE>];
Retrieves the attributes associated with an external control
Output format:

SID DATE TIME
M CTAG COMPLD
"<AID>:[<CONTTYPE>]"
;

RTRV-ATTR-ENV:[<TID>]:<AID>:<CTAG>::[<NTFCNCDE>],[<ALMTYPE>];
Retrieves the attributes associated with an environmental alarm
Output format:

SID DATE TIME
M CTAG COMPLD
"<AID>:[<NTFCNCDE>],[<ALMTYPE>],[<DESC>]"
;

RTRV-COND-ENV:[<TID>]:<AID>:<CTAG>::[<NTFCNCDE>],[<ALMTYPE>][,,,];
Retrieves the environmental conditions
Output format:

SID DATE TIME
M CTAG COMPLD
"<AID>:<NTFCNCDE>,<ALMTYPE>,,,,,,[<DESC>]"
;

RTRV-EXT-CONT:[<TID>]:<AID>:<CTAG>[::<CONTTYPE>];
Retrieves the control state of an external control
Output format:

SID DATE TIME
M CTAG COMPLD
"<AID>:[<CONTTYPE>],<DUR>,[<CONTSTATE>]"
;

SET-ATTR-CONT:[<TID>]:<AID>:<CTAG>[::<CONTTYPE>];
Sets the attributes associated with an external control

SET-ATTR-ENV:[<TID>]:<AID>:<CTAG>::[<NTFCNCDE>],[<ALMTYPE>],[<ALMMSG>];
Sets the attributes associated with an external alarm


4  Equipment

Table 4 Equipment 

ALW-SWDX-EQPT:[<TID>]:<AID>:<CTAG>[::];
Allows automatic or manual switching on a duplex system containing duplexed or redundant equipment

ALW-SWTOPROTN-EQPT:[<TID>]:<AID>:<CTAG>[::<DIRN>];
Allows automatic or manual switching of an equipment unit back to protection

ALW-SWTOWKG-EQPT:[<TID>]:<AID>:<CTAG>[::<DIRN>];
Allows automatic or manual switching of an equipment unit back to a working status

DLT-EQPT:[<TID>]:<AID>:<CTAG>[:::];
Deletes a card from the NE

ED-EQPT:[<TID>]:<AID>:<CTAG>:::[PROTID=<PROTID>,][PRTYPE=<PRTYPE>,]
[RVRTV=<RVRTV>,][RVTM=<RVTM>][:];
Edits the attributes for a given equipment slot in the NE

ENT-EQPT:[<TID>]:<AID>:<CTAG>::<AIDTYPE>:[PROTID=<PROTID>,]
[PRTYPE=<PRTYPE>,][RVRTV=<RVRTV>,][RVTM=<RVTM>][:];
Enters the card type and attributes for a given equipment slot in the NE

INH-SWDX-EQPT:[<TID>]:<AID>:<CTAG>[::];
Inhibits the automatic or manual switching on an NE containing duplex equipment

INH-SWTOPROTN-EQPT:[<TID>]:<AID>:<CTAG>[::<DIRN>];
Inhibits automatic or manual switching of an equipment unit to protection

INH-SWTOWKG-EQPT:[<TID>]:<AID>:<CTAG>[::<DIRN>];
Inhibits automatic or manual switching of an equipment unit back to the working unit

REPT ALM EQPT
Reports an alarm condition against an equipment unit or slot

REPT EVT EQPT
Reports the occurrence of a non-alarmed event against an equipment unit or slot

RTRV-ALM-EQPT:[<TID>]:<AID>:<CTAG>::[<NTFCNCDE>],[<CONDTYPE>],[<SRVEFF>][,,,];
Retrieves and sends the current status of alarm conditions associated with the equipment units
Output format:

SID DATE TIME
M CTAG COMPLD
"[<AID>],[<AIDTYPE>]:<NTFCNCDE>,<CONDTYPE>,<SRVEFF>,,,,:[<DESC>]"
;

RTRV-COND-EQPT:[<TID>]:<AID>:<CTAG>::[<TYPEREQ>][,,,];
Retrieves the condition equipment
Output format:

SID DATE TIME
M CTAG COMPLD
"<AID>,[<AIDTYPE>]:[<NTFCNCDE>],<TYPEREP>,[<SRVEFF>],,,,,[<DESC>]"
;

RTRV-EQPT:[<TID>]:<AID>:<CTAG>[::::];
Retrieves protection group information and status information for all cards
Output format:

SID DATE TIME
M CTAG COMPLD
"<AID>:<AIDTYPE>,<EQUIP>,[<ROLE>],[<STATUS>]:[PROTID=<PROTID>,]
[PRTYPE=<PRTYPE>,][RVRTV=<RVRTV>,][RVTM=<RVTM>,]
[CARDNAME=<CARDNAME>]:[<PST>],[<SST>]"
;

SW-DX-EQPT:[<TID>]:<AID>:<CTAG>::[<MODE>][,];
Switches an XC/XCVT card with the mate card within the NE

SW-TOPROTN-EQPT:[<TID>]:<AID>:<CTAG>::[<MODE>],[<PROTID>],[<DIRN>];
Performs an equipment unit protection switch

SW-TOWKG-EQPT:[<TID>]:<AID>:<CTAG>::[<MODE>],[<DIRN>];
Switches the protected working unit back to the working unit


5  Fault

Table 5 Fault 

REPT ALM <MOD2ALM>
Reports an alarm condition against a facility or a path

REPT ALM COM
Reports an alarm condition when an AID cannot be given

REPT ALM RING
Reports an alarm condition against a ring object for BLSR

REPT EVT <MOD2ALM>
Reports the occurrence of a non-alarmed event

REPT EVT COM
Reports a non-alarmed event against an NE when there is no AID associated with it

RTRV-ALM-<MOD2ALM>:[<TID>]:<AID>:<CTAG>::[<NTFCNCDE>],
[<CONDTYPE>],[<SRVEFF>][,,,]
Retrieves and sends the current status of the alarm conditions
Output format:

SID DATE TIME
M CTAG COMPLD
"<AID>,[<AIDTYPE>]:<NTFCNCDE>,<CONDTYPE>,<SRVEFF>,,,,:[<DESC>]"
;

RTRV-ALM-ALL:[<TID>]::<CTAG>::[<NTFCNCDE>],[<CONDITION>],[<SRVEFF>][,,,];
Retrieves and sends the current status of all active alarm conditions
Output format:

SID DATE TIME
M CTAG COMPLD
"[<AID>],[<AIDTYPE>]:<NTFCNCDE>,<CONDTYPE>,<SRVEFF>,,,,:[<DESC>],[<AIDDET>]"
;

RTRV-ALM-RING:[<TID>]:[<AID>]:<CTAG>::[<NTFCNCDE>],[<CONDITION>],
[<SRVEFF>][,,,];
Retrieves and sends the current status of all active alarm conditions against a ring object for BLSR
Output format:

SID DATE TIME
M CTAG COMPLD
"<AID>:<NTFCNCDE>,<CONDTYPE>,<SRVEFF>,,,,:[<DESC>]"
;

RTRV-COND-<MOD2ALM>:[<TID>]:<AID>:<CTAG>::[<TYPEREQ>][,,,];
Retrieves the current standing condition and/or state associated with an entity
Output format:
SID DATE TIME
M CTAG COMPLD
"<AID>,[<AIDTYPE>]:[<NTFCNCDE>],<TYPEREP>,[<SRVEFF>],,,,,[<DESC>]"
;

RTRV-COND-ALL:[<TID>]::<CTAG>::[<TYPEREQ>][,,,];
Retrieves the current standing condition for all entities
Output format:

SID DATE TIME
M CTAG COMPLD
"<AID>,[<AIDTYPE>]:[<NTFCNCDE>],<TYPEREP>,[<SRVEFF>],,,,,[<DESC>]"
;


6  Log

Table 6 Log 

ALW-MSG-DBCHG:[<TID>]::<CTAG>[::,,];
Enables REPT DBCHG

INH-MSG-DBCHG:[<TID>]::<CTAG>[::,,];
Disables REPT DBCHG

REPT DBCHG
Reports any changes on the NE that result from certain TL1 commands or an external event

RTRV-LOG:[<TID>]::<CTAG>::<LOGNM>;
Retrieves the alarm log of the NE
Output format:

SID DATE TIME
M CTAG COMPLD
"<AID>,<ALMNUMBER>:CURRENT=<CURRENT>,[PREVIOUS=<PREVIOUS>,]
<CONDITION>,<SRVEFF>,[TIME=<OCRTIME>,][DATE=<OCRDAT>]:<ALMDESCR>"
;


7  Performance

Table 7 Performance 

ALW-PMREPT-ALL:[<TID>]::<CTAG>;
Resumes processing all the PM reports that are inhibited

INH-PMREPT-ALL:[<TID>]::<CTAG>;
Inhibits all scheduled PM reporting

INIT-REG-<MOD2>:[<TID>]:<AID>:<CTAG>::,,[<LOCN>],[<DIRN>],[<TMPER>][,,];
Initializes the performance monitoring (PM) registers

REPT PM <MOD2>
Reports of Performance Monitoring statistics as a result of schedule created by SCHED-PMREPT

RTRV-PM-<MOD2>:[<TID>]:<AID>:<CTAG>::[<MONTYPE>],[<MONLEV>],
[<LOCN>],[<DIRN>],[<TMPER>],[<DATE>],[<TIME>];
Retrieves the values of PM parameters for a specified card type
Output format:

SID DATE TIME
M CTAG COMPLD
"<AID>,[<AIDTYPE>]:<MONTYPE>,<MONVAL>,[<VLDTY>],[<LOCN>],
[<DIRN>],[<TMPER>],[<MONDAT>],[<MONTM>]"
;

RTRV-PMMODE-<STS_PATH>:[<TID>]:AID>:<CTAG>::<LOCN>;
Retrieves the PM mode that has been previously set in the NE data collection
Output format:

SID DATE TIME
M CTAG COMPLD
"<AID>:[<LOCN>],<MODETYPE>"
;

RTRV-PMSCHED-<MOD2>:[<TID>]:<AID>:<CTAG>;
Retrieves the PM reporting schedule that was set for the NE by SCHED-PMREPT
Output format:

SID DATE TIME
M CTAG COMPLD
"<AID>,[<AIDTYPE>]:<REPTINVL>,<REPTDAT>,<REPTTM>,[<NUMINVL>],,
[<MONLEV>],<LOCN>,,[<TMPER>],,[<INHMODE>]"
;

RTRV-PMSCHED-ALL:[<TID>]::<CTAG>;
Retrieves all the PM reporting schedules that were set for the NE by SCHED-PMREPT
Output format:

M CTAG COMPLD
"<AID>,[<AIDTYPE>]:<REPTINVL>,<REPTDAT>,<REPTTM>,[<NUMINVL>],,
[<MONLEV>],<LOCN>,,[<TMPER>],,[<INHMODE>]"
;

RTRV-TH-<MOD2>:[<TID>]:<AID>:<CTAG>::[<MONTYPE>],[<LOCN>],[<TMPER>];
Retrieves the current threshold level of one or more monitored parameters
Output format:

SID DATE TIME
M CTAG COMPLD
"<AID>,[<AIDTYPE>]:<MONTYPE>,[<LOCN>],,<THLEV>,[<TMPER>]"
;

SCHED-PMREPT-<MOD2>:[<TID>]:<SRC>:<CTAG>::[<REPTINVL>],[<REPTSTATM>],
[<NUMREPT>],,[<MONLEV>],[<LOCN>],,[<TMPER>][,];
Schedules/reschedules the NE to report the performance monitoring data for a line facility or for an STS/VT path periodically, using an automatic REPT PM message

SET-PMMODE-<STS_PATH>:[<TID>]:<AID>:<CTAG>::<LOCN>,<MODETYPE>,[<PMSTATE>];
Sets the mode and turns on or off the mode of the PM data collection

SET-TH-<MOD2>:[<TID>]:<AID>:<CTAG>::<MONTYPE>,<THLEV>,[<LOCN>],,[<TMPER>];
Sets the threshold of PM parameters


8  Ports

Table 8 Ports 

ED-<OCN_TYPE>:[<TID>]:<AID>:<CTAG>:::[DCC=<DCC>,][SYNCMSG=<SYNCMSG>,]
[SENDDUS=<SENDDUS>,][PJMON=<PJMON>,][SFBER=<SFBER>,][SDBER=<SDBER>,]
[MODE=<MODE>,][MUX=<MUX>,][SOAK=<SOAK>]:[<PST>],[<SST>];
Edits the attributes and state of an OC-N facility

ED-DS1:[<TID>]:<AID>:<CTAG>[:::TACC=<TACC>];
Edits the test access attributes for DS1 access on a DS3XM

ED-EC1:[<TID>]:<AID>:<CTAG>:::[PJMON=<PJMON>,][LBO=<LBO>,]
[SOAK=<SOAK>]:[<PST>],[<SST>];
Edits the attributes of an EC1

ED-G1000:[<TID>]:<AID>:<CTAG>:::[MFS=<MFS>,][FLOW=<FLOW>]:[<PST>],[<SST>];
Edits the attributes related to a G1000 port

ED-T1:[<TID>]:<AID>:<CTAG>:::[LINECDE=<LINECDE>,][FMT=<FMT>,][LBO=<LBO>,]
[TACC=<TACC>,][SOAK=<SOAK>]:[<PST>],[<SST>];
Edits the attributes related a DS1/T1 port

ED-T3:[<TID>]:<AID>:<CTAG>:::[FMT=<FMT>,][LINECDE=<LINECDE>,][LBO=<LBO>,]
[TACC=<TACC>,][SOAK=<SOAK>]:[<PST>],[<SST>];
Edits the attributes related to a DS3/T3 port

REPT RMV <MOD2_IO>
Reports the occurrence of a non-alarm or event that is triggered by removing a facility

REPT RST <MOD2_IO>
Reports the occurrence of a non-alarm or event that is triggered by restoring a facility

RMV-<MOD2_IO>:[<TID>]:<AID>:<CTAG>::[<CMDMODE>],[<PST>],[<SST>];
Removes a facility from service

RST-<MOD2_IO>:[<TID>]:<AID>:<CTAG>:[:];
Provisions a facility in service

RTRV-<OCN_TYPE>:[<TID>]:<AID>:<CTAG>[::::];
Retrieves the attributes and state of an OC-N facility
Output format:

SID DATE TIME
M CTAG COMPLD
"<AID>:,,[<ROLE>],[<STATUS>]:[DCC=<DCC>,][TMGREF=<TMGREF>,]
[SYNCMSG=<SYNCMSG>,][SENDDUS=<SENDDUS>,][PJMON=<PJMON>,]
[SFBER=<SFBER>,][SDBER=<SDBER>,][MODE=<MODE>,][WVLEN=<WVLEN>,]
[RINGID=<RINGID>,][BLSRTYPE=<BLSRTYPE>,][MUX=<MUX>,][UNIC=<UNIC>,]
[CCID=<CCID>,][NBRIX=<NBRIX>,][SOAK=<SOAK>]:<PST>,[<SST>]"
;

RTRV-DS1:[<TID>]:<AID>:<CTAG>[::::];
Retrieves the test access attributes on a DS1 layer of DS3XM
Output format:

SID DATE TIME
M CTAG COMPLD
"<AID>::[TACC=<TACC>]"
;

RTRV-EC1:[<TID>]:<AID>:<CTAG>[::::];
Retrieves the facility status of an EC1 card
Output format:

SID DATE TIME
M CTAG COMPLD
"<AID>::[PJMON=<PJMON>,][LBO=<LBO>,][RXEQUAL=<RXEQUAL>,]
[SOAK=<SOAK>]:<PST>,[<SST>]"
;

RTRV-G1000:[<TID>]:<AID>:<CTAG>;
Retrieves the G1000 facilities configuration
Output format:

SID DATE TIME
M CTAG COMPLD
"<AID>::[MFS=<MFS>,][FLOW=<FLOW>,][LAN=<LAN>,]
[OPTICS=<OPTICS>]:<PST>,[<SST>]"
;

RTRV-T1:[<TID>]:<AID>:<CTAG>[::::];
Retrieves the DS1 facilities configuration
Output format:

SID DATE TIME
M CTAG COMPLD
"<AID>::[LINECDE=<LINECDE>,][FMT=<FMT>,][LBO=<LBO>,][TACC=<TAP>,]
[SOAK=<SOAK>]:<PST>,[<SST>]"
;

RTRV-T3:[<TID>]:<AID>:<CTAG>[::::];
Retrieves the facilities properties of a DS3 and DS3XM card
Output format:

SID DATE TIME
M CTAG COMPLD
"<AID>::[FMT=<FMT>,][LINECDE=<LINECDE>,][LBO=<LBO>,][TACC=<TAP>,]
[SOAK=<SOAK>]:<PST>,[<SST>]"
;


9  Security

Table 9 Security 

ACT-USER:[<TID>]:<UID>:<CTAG>::<PID>;
Sets up a session with the NE

CANC
Reports the occurrence of a session timeout event
Output format:

SID DATE TIME
A ATAG CANC
"<UID>"
;

CANC-USER:[<TID>]:<USERID>:<CTAG>;
Logs a user out of an active session with the NE

DLT-USER-SECU:[<TID>]:<UID>:<CTAG>;
Removes a user; can only be performed by a Superuser

ED-PID:[<TID>]:<UID>:<CTAG>::<OLDPID>,<NEWPID>;
Allows a user to change his or her own password

ED-USER-SECU:[<TID>]:<UID>:<CTAG>::[<NEWUID>],[<NEWPID>],,[<UAP>][:];
Edits a user's privileges, password, or ID and can only be performed by a Superuser

ENT-USER-SECU:[<TID>]:<UID>:<CTAG>::<PID>,,<UAP>[:];
Adds a user account; can only be performed by a Superuser

REPT EVT SECU
Reports the occurrence of a non-alarmed security event against the NE

RTRV-USER-SECU:[<TID>]:<UID>:<CTAG>;
Retrieves the security information of a specified user or list of users
Output format:

SID DATE TIME
M CTAG COMPLD
"<UID>:,<UAP>"
;


10  SONET Line Protection

Table 10 SONET Line Protection 

DLT-FFP-<OCN_TYPE>:[<TID>]:<WORK>,<PROTECT>:<CTAG>[:::];
Deletes an OC-N facility protection group in a 1+1 architecture

ED-FFP-<OCN_TYPE>:[<TID>]:<AID>:<CTAG>:::[PROTID=<PROTID>,][RVRTV=<RVRTV>,]
[RVTM=<RVTM>,][PSDIRN=<PSDIRN>][:];
Edits the optical facility protection

ENT-FFP-<OCN_TYPE>:[<TID>]:<WORK>,<PROTECT>:<CTAG>:::[PROTID=<PROTID>,]
[RVRTV=<RVRTV>,][RVTM=<RVTM>,][PSDIRN=<PSDIRN>][:];
Creates an optical 1+1 protection

EX-SW-<OCN_BLSR>:[TID]:<AID>:<CTAG>::[<ST>];
Exercises the algorithm for switching from a working facility to a protection facility without actually performing a switch

OPR-PROTNSW-<OCN_TYPE>:[<TID>]:<AID>:<CTAG>::<SC>,[<SWITCHTYPE>];
Initiates a SONET line protection switch request

RLS-PROTNSW-<OCN_TYPE>:[<TID>]:<AID>:<CTAG>[::];
Releases a SONET line protection switch request

RTRV-FFP-<OCN_TYPE>:[<TID>]:<AID>:<CTAG>[::::];
Retrieves the optical facility protection information
Output format:

SID DATE TIME
M CTAG COMPLD
"<WORK>,<PROTECT>::[PROTID=<PROTID>,][RVRTV=<RVRTV>,][RVTM=<RVTM>,]
[PSDIRN=<PSDIRN>]"
;


11  STS Paths

Table 11 STS Paths 

ED-<STS_PATH>:[<TID>]:<AID>:<CTAG>:::[SFBER=<SFBER>,][SDBER=<SDBER>,]
[RVRTV=<RVRTV>,][RVTM=<RVTM>,][SWPDIP=<SWPDIP>,][EXPTRC=<EXPTRC>,]
[TRC=<TRC>,][TRCMODE=<TRCMODE>,][TACC=<TACC>]:[<PST>],[<SST>];
Edits the attributes associated with an STS path

RTRV-<STS_PATH>:[<TID>]:<AID>:<CTAG>[::::];
Retrieves the attributes associated with an STS path
Output format:

SID DATE TIME
M CTAG COMPLD
"<AID>::[LEVEL=<LEVEL>,][SFBER=<SFBER>,][SDBER=<SDBER>,][RVRTV=<RVRTV>,]
[RVTM=<RVTM>,][SWPDIP=<SWPDIP>,][EXPTRC=<EXPTRC>,][TRC=<TRC>,]
[INCTRC=<INCTRC>,][TRCMODE=<TRCMODE>,][TACC=<TACC>]:<PST>,[<SST>]"
;

RTRV-PTHTRC-<STS_PATH>:[<TID>]:<AID>:<CTAG>::[<MSGTYPE>][:<LOCN>];
Retrieves the contents of the SONET path trace message that is transported in the J1 byte of the SONET STS path
Output format:

SID DATE TIME
M CTAG COMPLD
"<TRACMSG>"
;


12  STS and VT Paths

Table 12 STS and VT Paths 

ED-VT1:[<TID>]:<AID>:<CTAG>:::[RVRTV=<RVRTV>,][RVTM=<RVTM>,][TACC=<TACC>]:
[<PST>],[<SST>];
Edits the attributes associated with a VT1 path

RTRV-VT1:[<TID>]:<AID>:<CTAG>[::::];
Retrieves the attributes associated with a VT1 path
Output format:

SID DATE TIME
M CTAG COMPLD
"<AID>::[RVRTV=<RVRTV>,][RVTM=<RVTM>,][TACC=<TACC>]:[<PST>],[<SST>]"
;


13  Synchronization

Table 13 Synchronization 

ED-BITS:[<TID>]:<AID>:<CTAG>:::[LINECDE=<LINECDE>,][FMT=<FMT>,][LBO=<LBO>,]
[SYNCMSG=<SYNCMSG>,][AISTHRSHLD=<AISTHRSHLD>][:<PST>];
Edits the BITS reference attributes

ED-NE-SYNCN:[<TID>]::<CTAG>:::[TMMD=<TMMD>,][SSMGEN=<SSMGEN>,]
[QRES=<QRES>,][RVRTV=<RVRTV>,][RVTM=<RVTM>];
Edits the synchronization attributes of the NE

ED-SYNCN:[<TID>]:<AID>:<CTAG>:::[PRI=<PRI>,][SEC=<SEC>,][THIRD=<THIRD>][:];
Edits the synchronization reference list used to determine the sources for the NE's reference clock and the BITS output clock

OPR-SYNCNSW:[<TID>]:[<AID>]:<CTAG>::<SWITCHTO>,[<SC>];
Initiates a switch to the reference specified by the synchronization reference number if the reference supplied is valid

REPT ALM BITS
Reports an alarm condition on a BITS facility

REPT ALM SYNCN
Reports an alarm condition against a synchronization reference

REPT EVT BITS
Reports the occurrence of a non-alarmed event against a BITS facility

REPT EVT SYNCN
Reports the occurrence of a non-alarmed event against a synchronization entity

RLS-SYNCNSW:[<TID>]:[<AID>]:<CTAG>;
Releases the previous synchronization reference provided by the OPR-SYNCNSW command

RTRV-ALM-BITS:[<TID>]:<AID>:<CTAG>::[<NTFCNCDE>],[<CONDTYPE>],[<SRVEFF>][,,,];
Retrieves and sends the current status of alarm conditions associated with the BITS facility
Output format:

SID DATE TIME
M CTAG COMPLD
"<AID>,[<AIDTYPE>]:<NTFCNCDE>,<CONDTYPE>,<SRVEFF>,,,,:[<DESC>]"
;

RTRV-ALM-SYNCN:[<TID>]:<AID>:<CTAG>::[<NTFCNCDE>],[<CONDTYPE>],
[<SRVEFF>][,,,];
Retrieves and sends the current status of alarm conditions associated with a synchronization facility
Output format:

SID DATE TIME
M CTAG COMPLD
"<AID>,[<AIDTYPE>]:<NTFCNCDE>,<CONDTYPE>,<SRVEFF>,,,,:[<DESC>]"
;

RTRV-BITS:[<TID>]:<AID>:<CTAG>[::::];
Retrieves the BITS configuration command
Output format:

SID DATE TIME
M CTAG COMPLD
"<AID>::[LINECDE=<LINECDE>,][FMT=<FMT>,][LBO=<LBO>,][SYNCMSG=<SYNCMSG>,]
[AISTHRSHLD=<AISTHRSHLD>]:[<PST>]"
;

RTRV-COND-BITS:[<TID>]:<AID>:<CTAG>::[<TYPEREQ>][,,,];
Retrieves the standing condition on BITS
Output format:

SID DATE TIME
M CTAG COMPLD
"<AID>,[<AIDTYPE>]:[<NTFCNCDE>],<TYPEREP>,[<SRVEFF>],,,,,[<DESC>]"
;

RTRV-COND-SYNCN:[<TID>]:<AID>:<CTAG>::[<TYPEREQ>][,,,];
Retrieves the synchronization condition
Output format:

SID DATE TIME
M CTAG COMPLD
"<AID>,[<AIDTYPE>]:[<NTFCNCDE>],<TYPEREP>,[<SRVEFF>],,,,,[<DESC>]"
;

RTRV-NE-SYNCN:[<TID>]::<CTAG>[::::];
Retrieves the synchronization attributes of the NE
Output format:

SID DATE TIME
M CTAG COMPLD
"::[TMMD=<TMMD>,][SSMGEN=<SSMGEN>,][QRES=<QRES>,][RVRTV=<RVRTV>,]
[RVTM=<RVTM>]"
;

RTRV-SYNCN:[<TID>]:<AID>:<CTAG>[::::];
Retrieves the synchronization reference list used to determine the sources for the NE's reference clock and the BITS output clock
Output format:

SID DATE TIME
M CTAG COMPLD
"<AID>:<REF>,<REFVAL>,[<QREF>],[<STATUS>],[<PROTECTSTATUS>]"
;


14  System

Table 14 System 

ALW-MSG-ALL:[<TID>]::<CTAG>[::,,];
Allows REPT ALM and REPT EVT autonomous messages to be transmitted

APPLY:[<TID>]::<CTAG>[::<MEM_SW_TYPE>];
Activates or reverts a software load during a software upgrade or downgrade process

COPY-RFILE:[<TID>]:<SRC>:<CTAG>::TYPE=<XFERTYPE>,[SRC=<SRC1>];
Downloads a new software package from the location specified by the FTP URL

ED-DAT:[<TID>]::<CTAG>::[<DATE>],[<TIME>];
Edits the date and the time

ED-NE-GEN:[<TID>]::<CTAG>:::[NAME=<NAME>,][IPADDR=<IPADDR>,]
[IPMASK=<IPMASK>,][DEFRTR=<DEFRTR>,][IIOPPORT=<IIOPPORT>,][NTP=<NTP>];
Edits the general node attributes of an NE

INH-MSG-ALL:[<TID>]::<CTAG>[::,,];
Inhibits REPT ALM and REPT EVT autonomous messages from being transmitted

INIT-SYS:[<TID>]:<AID>:<CTAG>[::];
Initializes the specified card and its associated subsystem(s)

REPT EVT FXFR
Reports the FTP software download status of the start, completion, and completed percentage

RTRV-HDR:[<TID>]::<CTAG>;
Retrieves the header of a TL1 response message

RTRV-INV:[<TID>]:<AID>:<CTAG>[::::];
Retrieves a listing of the equipment inventory
Output format:

SID DATE TIME
M CTAG COMPLD
"<AID>,<AIDTYPE>::[PN=<PN>,][HWREV=<HWREV>,][FWREV=<FWREV>,]
[SN=<SN>,][CLEI=<CLEI>]"
;

RTRV-MAP-NETWORK:[<TID>]::<CTAG>;
Retrieves all the NE attributes which can be reached from the GNE
Output format:

SID DATE TIME
M CTAG COMPLD
"<IPADDR>,<NODENAME>,<PRODUCT>"
;

RTRV-NE-GEN:[<TID>]::<CTAG>;
Retrieves the general NE attributes
Output format:

SID DATE TIME
M CTAG COMPLD
"[IPADDR=<IPADDR>,][IPMASK=<IPMASK>,][DEFRTR=<DEFRTR>,]
[IIOPPORT=<IIOPPORT>,][NTP=<NTP>,][NAME=<NAME>,][SWVER=<SWVER>,]
[LOAD=<LOAD>,][PROTSWVER=<PROTSWVER>,][PROTLOAD=<PROTLOAD>,]
[DEFDESC=<DEFDESC>]"
;

RTRV-NE-IPMAP:[<TID>]:[<AID>]:<CTAG>;
Retrieves the IP addresses and the node names of the NEs which are DCC-connected to this NE
Output format:

SID DATE TIME
M CTAG COMPLD
"<AID>:<IPADDR>,<NODENAME>"
;

RTRV-TOD:[<TID>]::<CTAG>;
Retrieves the system date and time at the instant the command is executed
Output format:

SID DATE TIME
M CTAG COMPLD
"<YEAR>,<MONTH>,<DAY>,<HOUR>,<MINUTE>,<SECOND>,<TMTYPE>"
;

SET-TOD:[<TID>]::<CTAG>::<YEAR>,<MONTH>,<DAY>,<HOUR>,<MINUTE>,
<SECOND>,[<DIFFERENCE>][:DST=<DST>];
Sets the system date and time for the NE


15  Test Access

Table 15 Test Access 

CHG-ACCMD-<MOD_TACC>:[<TID>]:<TAP>:<CTAG>::<MD>;
Changes the test access mode for the circuit being tested

CONN-TACC-<MOD_TACC>:[<TID>]:<AID>:<CTAG>::<TAP>:MD=<MD>;
Connects the STS or VT defined by AID to the STS specified by the TAP number
Output format:

SID DATE TIME
M CTAG COMPLD
"<TAP>"
;

DISC-TACC:[<TID>]:<TAP>:<CTAG>;
Disconnects the TAP and puts the connection back to its original state

RTRV-TACC:[<TID>]:<TAP>:<CTAG>;
Retrieves details associated with a TAP
Output format:

SID DATE TIME
M CTAG COMPLD
"<TAP>:<TACC_AID1>,<TACC_AID2>,[<MD>],[<E_CONN>],[<F_CONN>]"
;


16  Testing

Table 16 Testing 

OPR-LPBK-<MOD2_IO>:[<TID>]:<AID>:<CTAG>::,,,[<LPBKTYPE>];
Operates a signal loopback on an I/O card

RLS-LPBK-<MOD2_IO>:[<TID>]:<AID>:<CTAG>::,,,[<LPBKTYPE>];
Releases a signal loopback on an I/O card


17  UCP

Table 17 UCP 

DLT-UCP-CC:[<TID>]:<AID>:<CTAG>[::::];
Deletes an UCP IP control channel

DLT-UCP-IF:[<TID>]:<AID>:<CTAG>[::::];
Deletes an UCP interface

DLT-UCP-NBR:[<TID>]:<AID>:<CTAG>[::::];
Deletes an UCP neighbor

ED-UCP-CC:[<TID>]:<AID>:<CTAG>:::[LOCALIPCC=<LOCALIPCC>,]
[REMOTEIPCC=<REMOTEIPCC>,][LMPHELLOINT=<LMPHELLOINT>,]
[LMPHELLODEADINT=<LMPHELLODEADINT>,][MTU=<MTU>,][CRCMD=<CRCMD>][:];
Edits UCP IP control channel attributes

ED-UCP-IF:[<TID>]:<AID>:<CTAG>:::[TNATYPE=<TNATYPE>,][TNAADDR=<TNAADDR>,]
[CORENETWORKID=<CORENETWORKID>][:];
Edits UCP interface attributes

ED-UCP-NBR:[<TID>]:<AID>:<CTAG>:::[NAME=<NAME>,][HELLOEN=<HELLOEN>,]
[HELLOINT=<HELLOINT>,][REFREDEN=<REFREDEN>][:];
Edits an UCP neighbor

ED-UCP-NODE:[<TID>]::<CTAG>:::[NODEID=<NODEID>,][INITRETRY=<INITRETRY>,]
[MAXRETRY=<MAXRETRY>,][RESTARTTM=<RESTARTTM>,][RECOVTM=<RECOVTM>,]
[RXMTINT=<RXMTINT>,][RFRSHINT=<RFRSHINT>,][RESVTIMEOUT=<RESVTIMEOUT>,]
[RESVCONFTIMEOUT=<RESVCONFTIMEOUT>,][SOURCEDIP=<SOURCEDIP>,]
[DESTINATIONDIP=<DESTINATIONDIP>][:];
Edits the UCP node level attributes

ENT-UCP-CC:[<TID>]:[<AID>]:<CTAG>:::[NBRIX=<NBRIX>,][CCTYPE=<CCTYPE>,]
[PORT=<PORT>,][LOCALCCID=<LOCALCCID>,][LOCALIPCC=<LOCALIPCC>,]
[REMOTCCID=<REMOTECCID>,][REMOTEIPCC=<REMOTEIPCC>,]
[LMPHELLOINT=<LMPHELLOINT>,][LMPHELLODEADINT=<LMPHELLODEADINT>,]
[MTU=<MTU>,][CRCMD=<CRCMD>,][TUNMD=<TUNMD>][:];
Creates an UCP IP control channel

ENT-UCP-IF:[<TID>]:<AID>:<CTAG>:::[NBRIX=<NBRIX>,][CCID=<CCID>,]
[LOCALIFID=<LOCALIFID>,][REMOTEIFID=<REMOTEIFID>,][TNATYPE=<TNATYPE>,]
[TNAADDR=<TNAADDR>,][CORENETWORKID=<CORENETWORKID>][:];
Creates an UCP interface

ENT-UCP-NBR:[<TID>]:<AID>:<CTAG>:::[NBRIX=<NBRIX>,][NODEID=<NODEID>,]
NAME=<NAME>,[NDEN=<NDEN>,][HELLOEN=<HELLOEN>,][HELLOINT=<HELLOINT>,]
[REFREDEN=<REFREDEN>,][NUMRXMTS=<NUMRXMTS>][:];
Creates an UCP neighbor

REPT ALM UCP
Reports an alarm condition against an UCP object

REPT EVT UCP
Reports the occurrence of a non-alarmed event against an UCP object

RTRV-ALM-UCP:[<TID>]:<AID >:<CTAG>::[<NTFCNCDE>],[<CONDTYPE>],[<SRVEFF>][,,,];
Retrieves and sends the current status of all active alarm conditions against an UCP object
Output format:

SID DATE TIME
M CTAG COMPLD
"<AID>:<NTFCNCDE>,<CONDTYPE>,<SRVEFF>,,,,:[<DESC>]"
;

RTRV-COND-UCP:[<TID>]:<AID>:<CTAG>::[<TYPEREQ>][,,,];
Retrieves the current standing condition against an UCP object
Output format:

SID DATE TIME
M CTAG COMPLD
"<AID>:[<NTFCNCDE>],<TYPEREP>,[<SRVEFF>],,,,,[<DESC>]"
;

RTRV-UCP-CC:[<TID>]:[<AID >]:<CTAG>[::::];
Retrieves UCP IP control channel attributes
Output format:

SID DATE TIME
M CTAG COMPLD
"[<AID>]::NBRIX=<NBRIX>,CCTYPE=<CCTYPE>,[PORT=<PORT>,]
LOCALCCID=<LOCALCCID>,LOCALIPCC=<LOCALIPCC>,
REMOTECCID=<REMOTECCID>,[REMOTEIPCC=<REMOTEIPCC>,]
LMPHELLOINT=<LMPHELLOINT>,OPERLMPHELLOINT=<OPERLMPHELLOINT>,
LMPHELLODEADINT=<LMPHELLODEADINT>,
OPERLMPHELLODEADINT=<OPERLMPHELLODEADINT>,[TUNMD=<TUNMD>,]
[MTU=<MTU>,][CRCMD=<CRCMD>]"
;

RTRV-UCP-IF:[<TID>]:[<AID>]:<CTAG>[::::];
Retrieves UCP interface attributes
Output formats:

SID DATE TIME
M CTAG COMPLD
"[<AID>]::NBRIX=<NBRIX>,CCID=<CCID>,LOCALIFID=<LOCALIFID>,
REMOTEIFID=<REMOTEIFID>,TNATYPE=<TNATYPE>,TNAADDR=<TNAADDR>,
CORENETWORKID=<CORENETWORKID>"
;

RTRV-UCP-NBR:[<TID>]:[<AID>]:<CTAG>[::::];
Retrieves an UCP neighbor
Output format:

SID DATE TIME
M CTAG COMPLD
"<AID>::[NBRIX=<NBRIX>,][NODEID=<NODEID>,][NAME=<NAME>,]
[NDEN=<NDEN>,][HELLOEN=<HELLOEN>,][HELLOINT=<HELLOINT>,]
[REFREDEN=<REFREDEN>,][NUMRXMTS=<NUMRXMTS>]"
;

RTRV-UCP-NODE:[<TID>]::<CTAG>[::::];
Retrieves UCP node-level attributes
Output formats:

SID DATE TIME
M CTAG COMPLD
"<::[NODEID=<NODEID>,][INITRETRY=<INITRETRY>,][MAXRETRY=<MAXRETRY>,]
[RESTARTTM=<RESTARTTM>,][RECOVTM=<RECOVTM>,][RXMTINT=<RXMTINT>,]
[RFRSHINT=<RFRSHINT>,][RESVTIMEOUT=<RESVTIMEOUT>,]
[RESVCONFTIMEOUT=<RESVCONFTIMEOUT>,][SOURCEDIP=<SOURCEDIP>,]
[DESTINATIONDIP=<DESTINATIONDIP>]"
;


18  UPSR Switching

Table 18 UPSR Switching 

OPR-PROTNSW-<STS_PATH>:[<TID>]:<AID>:<CTAG>::<SC>[:];
Initiates a SONET path protection (UPSR) switch request

OPR-PROTNSW-VT1:[<TID>]:<AID>:<CTAG>::<SC>[:];
Initiates a SONET path protection (UPSR) switch request

REPT SW
Reports the autonomous switching of a unit in a duplex equipment pair to standby and its mate to the active state

RLS-PROTNSW-<STS_PATH>:[<TID>]:<AID>:<CTAG>[::];
Releases a SONET path protection switch request that was established with the OPR-PROTNSW-<STS_PATH> command

RLS-PROTNSW-VT1:[<TID>]:<AID>:<CTAG>[::];
Releases a SONET path protection switch request that was established with the OPR-PROTNSW-VT1 command

RTRV-PROTNSW-<STS_PATH>:[<TID>]:<AID>:<CTAG>[::::];
Retrieves the switching state of a SONET UPSR STS path specified in the AID
Output format:

SID DATE TIME
M CTAG COMPLD
"<AID>:<SC>,[<SWITCHTYPE>]"
;

RTRV-PROTNSW-VT1:[<TID>]:<AID>:<CTAG>[::::];
Retrieves the switching state of a SONET UPSR VT path specified in the AID
Output format:

SID DATE TIME
M CTAG COMPLD
"<AID>:<SC>,[<SWITCHTYPE>]"
;



hometocprevnextglossaryfeedbacksearchhelp

Posted: Fri Feb 22 15:18:28 PST 2008
All contents are Copyright © 1992--2008 Cisco Systems, Inc. All rights reserved.
Important Notices and Privacy Statement.